101
|
Samuni Y, Ishii H, Hyodo F, Samuni U, Krishna MC, Goldstein S, Mitchell JB. Reactive oxygen species mediate hepatotoxicity induced by the Hsp90 inhibitor geldanamycin and its analogs. Free Radic Biol Med 2010; 48:1559-63. [PMID: 20211249 PMCID: PMC2862863 DOI: 10.1016/j.freeradbiomed.2010.03.001] [Citation(s) in RCA: 60] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2009] [Revised: 02/24/2010] [Accepted: 03/01/2010] [Indexed: 11/19/2022]
Abstract
Geldanamycin (GM), a benzoquinone ansamycin antibiotic, is a natural product inhibitor of Hsp90 with potent and broad anti-cancer properties. Because of its adverse effects on liver, its less toxic derivatives 17-(allylamino)-17-demethoxygeldanamycin (17-AAG) and 17-(dimethylaminoethylamino)-17-demethoxygeldanamycin (17-DMAG) are currently being evaluated for the treatment of cancer. Previously, it has been demonstrated that the redox cycling of GM by NADPH-cytochrome P450 reductase leads to the formation of the GM semiquinone and superoxide radicals, the latter being identified using spin-trapping. We hypothesized that the different hepatotoxicity induced by GM, 17-AAG and 17-DMAG reflects the redox active properties of the quinone moiety and possibly the extent of superoxide formation, which may stimulate cellular oxidative injury. Our data demonstrate that superoxide can be efficiently trapped during the reduction of GM, 17-AAG and 17-DMAG by NADPH-cytochrome P450 reductase, and that superoxide formation rate followed the order 17-DMAG > 17-AAG > GM. In the absence of superoxide scavengers, the rate of NADPH oxidation followed the order 17-DMAG > GM > 17-AAG. The half-wave one-electron reduction potentials (E(1/2)) of GM, 17-AAG and 17-DMAG in DMSO have been determined to be -0.37, -0.13 and -0.015V (vs. Ag/AgCl), respectively. If the same order of E(1/2) follows in neutral aqueous media, thermodynamic considerations imply that 17-DMAG is more readily reduced by the P450 reductase as well as by superoxide. The order of the drug cytotoxicity toward rat primary hepatocytes, as determined by their effect on cell viability and on intracellular oxidant level, was opposite to the order of E(1/2) of the respective quinone/semiquinone couples. These results suggest that hepatotoxicity exhibited by the Hsp90 inhibitors belonging to benzoquinone ansamycins could be attributed to superoxide. The apparent discrepancy between the order of toxicity and the orders of superoxide formation rate, which is correlated with E(1/2), is discussed.
Collapse
|
102
|
Takeshita K, Kawaguchi K, Fujii-Aikawa K, Ueno M, Okazaki S, Ono M, Krishna MC, Kuppusamy P, Ozawa T, Ikota N. Heterogeneity of regional redox status and relation of the redox status to oxygenation in a tumor model, evaluated using electron paramagnetic resonance imaging. Cancer Res 2010; 70:4133-40. [PMID: 20442282 DOI: 10.1158/0008-5472.can-09-4369] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
It is widely accepted that redox status, along with the partial pressure of oxygen (pO(2)), determines the efficacy of some therapeutic methods applied to treat tumors, including radiation. Redox status, evaluated by the reduction of a nitroxyl probe, was reportedly heterogeneous in a mouse tumor model. However, neither variation of heterogeneity of the redox status among mice nor the relation of the redox status to pO(2) in tumors has been characterized sufficiently. In this study, the regional reduction status in a mouse radiation-induced fibrosarcoma tumor model was evaluated using sequential three-dimensional electron paramagnetic resonance (EPR) imaging after i.v. injection of a tissue-permeable nitroxyl probe, HM-PROXYL. The regional decay of HM-PROXYL signal obeyed first-order kinetics, and the amplitude of the reduction rate and extent of its heterogeneity in a tumor varied among six mice. The tissue pO(2) was measured using EPR oximetry with lithium phthalocyanine (LiPc) microcrystals implanted within the tumor. The location of LiPc was determined with EPR imaging. A sequential image was obtained following the injection of HM-PROXYL, even after LiPc implantation, by choosing an HM-PROXYL signal peak which does not overlap with the signal of LiPc. The relationship between pO(2) and the reduction rate at the region of pO(2) measurement was found to be low (r = 0.357) in 13 tumor-bearing mice, indicating that the extent of oxygenation does not necessarily affect the redox status under air-breathing conditions. The results strongly indicate the necessity of measurements of both redox status and oxygenation in every tumor to characterize tumor physiology.
Collapse
|
103
|
Hyodo F, Chandramouli GVR, Matsumoto S, Matsumoto KI, Mitchell JB, Krishna MC, Munasinghe JP. Estimation of tumor microvessel density by MRI using a blood pool contrast agent. Int J Oncol 2009; 35:797-804. [PMID: 19724915 DOI: 10.3892/ijo_00000392] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023] Open
Abstract
Recognition of importance of angiogenesis to tumor growth, metastasis, and treatment outcome has led to efforts to develop non-invasive methods for longitudinal monitoring of tumor microvasculature. We describe a steady-state MRI technique to determine absolute blood volume (BV) as a marker of microvascular density with improved spatial and temporal resolution using an ultra small super paramagnetic iron oxide (USPIO). A noise reduction scheme for BV imaging was also proposed based on weighting factors derived by pre-contrast signal level as an adjustable additive constant. Gradient echo sequence was used for BV imaging with MRI at 7T. Optimal imaging conditions (USPIO dose and echo time) were determined by USPIO dose-dependent studies ex vivo and in vivo. Improved analysis strategies were at first applied for cerebral BV estimation in mice, which were found in good agreement with the literature values. These methods were then used to determine tumor BV in mice. The optimal concentration of USPIO for BV estimates was found to range from 3.6 to 4.48 mM (estimated as Fe concentration) in ex vivo experiments corresponding to an in vivo dosage of 215-287 micromol/kg body weight, whereas a USPIO dose of 287 micromol/kg leads to higher cerebral BV estimate in vivo than the reported values. Application of the BV imaging method to evaluation of anti-angiogenic effect of Sunitinib in squamous cell carcinoma (SCC) tumor bearing mice revealed approximately 46% reduction in tumor BV 4 days after start of Sunitinib treatment. The results show that the MRI approach using USPIO yields high-resolution absolute BV images and the method can be conveniently applied to monitor longitudinal tumor microvessel density changes as a function of growth or in response to treatment.
Collapse
|
104
|
Samuni Y, Flores-Santana W, Krishna MC, Mitchell JB, Wink DA. The inhibitors of histone deacetylase suberoylanilide hydroxamate and trichostatin A release nitric oxide upon oxidation. Free Radic Biol Med 2009; 47:419-23. [PMID: 19447172 PMCID: PMC2730666 DOI: 10.1016/j.freeradbiomed.2009.05.011] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2009] [Revised: 05/07/2009] [Accepted: 05/09/2009] [Indexed: 11/16/2022]
Abstract
Suberoylanilide hydroxamic acid (SAHA, vorinostat, Zolinza) is the lead compound of a new class of histone deacetylase (HDAC) inhibitors used as anticancer drugs that have been shown to affect multiple proteins associated with gene expression, cell proliferation, and migration. Studies have also demonstrated the essential role of the hydroxamate moiety of SAHA in HDAC inhibition. The ability of SAHA and its structural analog trichostatin A (TSA) to generate NO upon oxidation was tested directly, by spin trapping of NO using electron paramagnetic resonance spectroscopy, and also indirectly, via the determination of nitrite using the Griess assay. H2O2/metmyoglobin was used to oxidize SAHA and TSA. These studies demonstrate, for the first time, the release of NO from SAHA and its structural analog TSA. We tested the protective effects of SAHA, TSA, and valproic acid (VPA) in mammalian Chinese hamster V79 cells exposed to a bolus of H2O2 for 1 h and monitored the clonogenic cell survival. Both SAHA and TSA afforded significant cytoprotection when co-incubated with H2O2, whereas VPA was ineffective. These studies provide evidence for the release of NO by hydroxamate-containing HDAC inhibitors and their antioxidant effects. Such roles may be an added advantage of this class of HDAC agents used for epigenetic therapies in cancer.
Collapse
|
105
|
Meenakshisundaram G, Eteshola E, Pandian RP, Bratasz A, Selvendiran K, Lee SC, Krishna MC, Swartz HM, Kuppusamy P. Oxygen sensitivity and biocompatibility of an implantable paramagnetic probe for repeated measurements of tissue oxygenation. Biomed Microdevices 2009; 11:817-26. [PMID: 19319683 PMCID: PMC2756533 DOI: 10.1007/s10544-009-9298-4] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
The use of oxygen-sensing water-insoluble paramagnetic probes, such as lithium octa-n-butoxynaphthalocyanine (LiNc-BuO), enables repeated measurements of pO(2) from the same location in tissue by electron paramagnetic resonance (EPR) spectroscopy. In order to facilitate direct in vivo application, and hence eventual clinical applicability, of LiNc-BuO, we encapsulated LiNc-BuO microcrystals in polydimethylsiloxane (PDMS), an oxygen-permeable and bioinert polymer, and developed an implantable chip. In vitro evaluation of the chip, performed under conditions of sterilization, high-energy irradiation, and exposure to cultured cells, revealed that it is biostable and biocompatible. Implantation of the chip in the gastrocnemius muscle tissue of mice showed that it is capable of repeated and real-time measurements of tissue oxygenation for an extended period. Functional evaluation using a murine tumor model established the suitability and applicability of the chip for monitoring tumor oxygenation. This study establishes PDMS-encapsulated LiNc-BuO as a promising choice of probe for clinical EPR oximetry.
Collapse
|
106
|
Matsumoto KI, Okajo A, Nagata K, Degraff WG, Nyui M, Ueno M, Nakanishi I, Ozawa T, Mitchell JB, Krishna MC, Yamamoto H, Endo K, Anzai K. Detection of free radical reactions in an aqueous sample induced by low linear-energy-transfer irradiation. Biol Pharm Bull 2009; 32:542-7. [PMID: 19336881 DOI: 10.1248/bpb.32.542] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Quantitative detection of free radical reactions induced by low linear-energy-transfer (LET) irradiation in an aqueous solution was attempted using nitroxyl radicals. The stability and reactivity of reaction mixtures containing a nitroxyl radical and a hydrogen donor, i.e., glutathione (GSH), nicotinamide adenine dinucleotide (NADH), or nicotinamide adenine dinucleotide phosphate (NADPH), were tested. X-band electron paramagnetic resonance (EPR) measurements of several reaction mixtures were performed to find a suitable preparation to quantitatively detect free radical reactions produced by low LET irradiation. The EPR signal intensity of nitroxyl radicals was decreased by low LET irradiation when a hydrogen donor coexisted in the reaction mixture. The combination of 4-hydroxy-2,2,6,6-tetramethylpiperidine-N-oxyl (4-hydroxy-TEMPO, known as TEMPOL) and GSH was most preferable among other preparations tested in this paper, because of the sensitivity and irreversible reaction. The extent of the free radical reaction, i.e., formation of reactive oxygen species, in the reaction mixture depended on the radiation energy when an identical dose was given.
Collapse
|
107
|
Hyodo F, Matsumoto S, Devasahayam N, Dharmaraj C, Subramanian S, Mitchell JB, Krishna MC. Pulsed EPR imaging of nitroxides in mice. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2009; 197:181-5. [PMID: 19157932 PMCID: PMC3496157 DOI: 10.1016/j.jmr.2008.12.018] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2008] [Accepted: 12/16/2008] [Indexed: 05/05/2023]
Abstract
Nitroxides, unlike trityl radicals, have shorter T(2)s which until now were not detectable in vivo by a time-domain pulsed Electron Paramagnetic Resonance (EPR) spectrometer at 300 MHz since their phase memory times were shorter than the spectrometer recovery times. In the current version of the time-domain EPR spectrometer with improved spectrometer recovery times, the feasibility of detecting signals from nitroxide radicals was tested. Among the nitroxides evaluated, deuterated (15)N-Tempone ((15)N-PDT) was found to have the longest T(2). The signal intensity profile as a function of concentration of these agents was evaluated and a biphasic behavior was observed; beyond a nitroxide concentration of 1.5mM, signal intensity was found to decrease as a result of self-broadening. Imaging experiments were carried out with (15)N-PDT in solutions equilibrated with 0%, 5%, 10%, and 21% oxygen using the single point imaging (SPI) modality in EPR. The image intensity in these tubes was found to depend on the oxygen concentration which in turn influences the T(2) of (15)N-PDT. In vivo experiments were demonstrated with (15)N-PDT in anesthetized mice where the distribution and metabolism of (15)N-PDT could be monitored. This study, for the first time shows the capability to image a cell-permeable nitroxide in mice using pulsed EPR in the SPI modality.
Collapse
|
108
|
Hyodo F, Soule BP, Matsumoto KI, Matusmoto S, Cook JA, Hyodo E, Sowers AL, Krishna MC, Mitchell JB. Assessment of tissue redox status using metabolic responsive contrast agents and magnetic resonance imaging. J Pharm Pharmacol 2008; 60:1049-60. [PMID: 18644197 DOI: 10.1211/jpp.60.8.0011] [Citation(s) in RCA: 71] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Regulation of tissue redox status is important to maintain normal physiological conditions in the living body. Disruption of redox homoeostasis may lead to oxidative stress and can induce many pathological conditions such as cancer, neurological disorders and ageing. Therefore, imaging of tissue redox status could have clinical applications. Redox imaging employing magnetic resonance imaging (MRI) with nitroxides as cell-permeable redox-sensitive contrast agents has been used for non-invasive monitoring of tissue redox status in animal models. The redox imaging applications of nitroxide electron paramagnetic resonance imaging (EPRI) and MRI are reviewed here, with a focus on application of tumour redox status monitoring. While particular emphasis has been placed on differences in the redox status in tumours compared to selected normal tissues, the technique possesses the potential to have broad applications to the study of other disease states, inflammatory processes and other circumstances where oxidative stress is implicated.
Collapse
|
109
|
Subramanian S, Krishna MC. DANCING WITH THE ELECTRONS: TIME-DOMAIN AND CW IN VIVO EPR IMAGING. MAGNETIC RESONANCE INSIGHTS 2008; 2:43-74. [PMID: 22025900 DOI: 10.4137/mri.s1131] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
The progress in the development of imaging the distribution of unpaired electrons in living systems and the functional and the potential diagnostic dimensions of such an imaging process, using Electron Paramagnetic Resonance Imaging (EPRI), is traced from its origins with emphasis on our own work. The importance of EPR imaging stems from the fact that many paramagnetic probes show oxygen dependent spectral broadening. Assessment of in vivo oxygen concentration is an important factor in radiation oncology in treatment-planning and monitoring treatment-outcome. The emergence of narrow-line trairylmethyl based, bio-compatible spin probes has enabled the development of radiofrequency time-domain EPRI. Spectral information in time-domain EPRI can be achieved by generating a time sequence of T(2)* or T(2) weighted images. Progress in CW imaging has led to the use of rotating gradients, more recently rapid scan with direct detection, and a combination of all the three. Very low field MRI employing Dynamic Nuclear polarization (Overhauser effect) is also employed for monitoring tumor hypoxia, and re-oxygenation in vivo. We have also been working on the co-registration of MRI and time domain EPRI on mouse tumor models at 300 MHz using a specially designed resonator assembly. The mapping of the unpaired electron distribution and unraveling the spectral characteristics by using magnetic resonance in presence of stationary and rotating gradients in indeed 'dancing with the (unpaired) electrons', metaphorically speaking.
Collapse
|
110
|
Kulkarni AC, Bratasz A, Rivera B, Krishna MC, Kuppusamy P. Redox Mapping of Biological Samples Using EPR Imaging. Isr J Chem 2008. [DOI: 10.1560/ijc.48.1.27] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
111
|
Chen Q, Espey MG, Sun AY, Pooput C, Kirk KL, Krishna MC, Khosh DB, Drisko J, Levine M. Pharmacologic doses of ascorbate act as a prooxidant and decrease growth of aggressive tumor xenografts in mice. Proc Natl Acad Sci U S A 2008; 105:11105-9. [PMID: 18678913 PMCID: PMC2516281 DOI: 10.1073/pnas.0804226105] [Citation(s) in RCA: 574] [Impact Index Per Article: 35.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2008] [Indexed: 12/17/2022] Open
Abstract
Ascorbic acid is an essential nutrient commonly regarded as an antioxidant. In this study, we showed that ascorbate at pharmacologic concentrations was a prooxidant, generating hydrogen-peroxide-dependent cytotoxicity toward a variety of cancer cells in vitro without adversely affecting normal cells. To test this action in vivo, normal oral tight control was bypassed by parenteral ascorbate administration. Real-time microdialysis sampling in mice bearing glioblastoma xenografts showed that a single pharmacologic dose of ascorbate produced sustained ascorbate radical and hydrogen peroxide formation selectively within interstitial fluids of tumors but not in blood. Moreover, a regimen of daily pharmacologic ascorbate treatment significantly decreased growth rates of ovarian (P < 0.005), pancreatic (P < 0.05), and glioblastoma (P < 0.001) tumors established in mice. Similar pharmacologic concentrations were readily achieved in humans given ascorbate intravenously. These data suggest that ascorbate as a prodrug may have benefits in cancers with poor prognosis and limited therapeutic options.
Collapse
|
112
|
Matsumoto S, Hyodo F, Subramanian S, Devasahayam N, Munasinghe J, Hyodo E, Gadisetti C, Cook JA, Mitchell JB, Krishna MC. Low-field paramagnetic resonance imaging of tumor oxygenation and glycolytic activity in mice. J Clin Invest 2008; 118:1965-73. [PMID: 18431513 DOI: 10.1172/jci34928] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2008] [Accepted: 03/05/2008] [Indexed: 12/16/2022] Open
Abstract
A priori knowledge of spatial and temporal changes in partial pressure of oxygen (oxygenation; pO(2)) in solid tumors, a key prognostic factor in cancer treatment outcome, could greatly improve treatment planning in radiotherapy and chemotherapy. Pulsed electron paramagnetic resonance imaging (EPRI) provides quantitative 3D maps of tissue pO(2) in living objects. In this study, we implemented an EPRI set-up that could acquire pO(2) maps in almost real time for 2D and in minutes for 3D. We also designed a combined EPRI and MRI system that enabled generation of pO(2) maps with anatomic guidance. Using EPRI and an air/carbogen (95% O(2) plus 5% CO(2)) breathing cycle, we visualized perfusion-limited hypoxia in murine tumors. The relationship between tumor blood perfusion and pO(2) status was examined, and it was found that significant hypoxia existed even in regions that exhibited blood flow. In addition, high levels of lactate were identified even in normoxic tumor regions, suggesting the predominance of aerobic glycolysis in murine tumors. This report presents a rapid, noninvasive method to obtain quantitative maps of pO(2) in tumors, reported with anatomy, with precision. In addition, this method may also be useful for studying the relationship between pO(2) status and tumor-specific phenotypes such as aerobic glycolysis.
Collapse
|
113
|
Matsumoto S, Espey MG, Utsumi H, Devasahayam N, Matsumoto KI, Matsumoto A, Hirata H, Wink DA, Kuppusamy P, Subramanian S, Mitchell JB, Krishna MC. Dynamic monitoring of localized tumor oxygenation changes using RF pulsed electron paramagnetic resonance in conscious mice. Magn Reson Med 2008; 59:619-25. [PMID: 18224698 DOI: 10.1002/mrm.21500] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Oxygenation status is a key determinant in both tumor growth and responses to therapeutic interventions. The oxygen partial pressure (pO2) was assessed using a novel pulsed electron paramagnetic resonance (EPR) spectroscopy at 750 MHz. Crystals of lithium phthalocyanine (LiPc) implanted into either squamous cell carcinoma (SCC) tumor or femoral muscle on opposing legs of mice were tested by pulsed EPR. The results showed pO2 of SCC tumor was 2.7 +/- 0.4 mmHg, while in the femoral muscle it was 6.1 +/- 0.9 mmHg. A major advantage of pulsed EPR oximetry over conventional continuous-wave (CW) EPR oximetry is the lack of influence from subject motion, while avoiding artifacts associated with modulation or power saturation. Resonators in pulsed EPR are overcoupled to minimize recovery time. This makes changes in coupling associated with object motion minimal without influencing spectral quality. Consequently, pulsed EPR oximetry enables approximately a temporal resolution of approximately one second in pO2 monitoring in conscious subjects, avoiding significant influence of anesthetics on the physiology being studied. The pO2 in SCC tumor and muscle was found to be higher without anesthesia (3.9 +/- 0.5 mmHg for tumor, 8.8 +/- 1.2 mmHg for muscle). These results support the advantage of pulsed EPR in examining pO2 in conscious animals with LiPc chronically implanted in predetermined regions.
Collapse
|
114
|
Hyodo F, Chuang KH, Goloshevsky AG, Sulima A, Griffiths GL, Mitchell JB, Koretsky AP, Krishna MC. Brain redox imaging using blood-brain barrier-permeable nitroxide MRI contrast agent. J Cereb Blood Flow Metab 2008; 28:1165-74. [PMID: 18270519 PMCID: PMC3197772 DOI: 10.1038/jcbfm.2008.5] [Citation(s) in RCA: 75] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Reactive oxygen species (ROS) and compromised antioxidant defense may contribute to brain disorders such as stroke, amyotrophic lateral sclerosis, etc. Nitroxides are redox-sensitive paramagnetic contrast agents and antioxidants. The ability of a blood-brain barrier (BBB)-permeable nitroxide, methoxycarbonyl-2,2,5,5-tetramethylpyrrolidine-1-oxyl (MC-P), as a magnetic resonance-imaging (MRI) contrast agent for brain tissue redox imaging was tested. MC-P relaxation in rodent brain was quantified by MRI using a fast Look-Locker T(1)-mapping sequence. In the cerebral cortex and thalamus, the MRI signal intensity increased up to 50% after MC-P injection, but increased only by 2.7% when a BBB-impermeable nitroxide, 3CxP (3-carboxy-2,2,5,5,5-tetramethylpyrrolidine-1-oxyl) was used. The maximum concentrations in the thalamus and cerebral cortex after MC-P injection were calculated to be 1.9+/-0.35 and 3.0+/-0.50 mmol/L, respectively. These values were consistent with the ex vivo data of brain tissue and blood concentration obtained by electron paramagnetic resonance (EPR) spectroscopy. Also, reduction rates of MC-P were significantly decreased after reperfusion following transient MCAO (middle cerebral artery occlusion), a condition associated with changes in redox status resulting from oxidative damage. These results show the use of BBB-permeable nitroxides as MRI contrast agents and antioxidants to evaluate the role of ROS in neurologic diseases.
Collapse
|
115
|
Devasahayam N, Subramanian S, Krishna MC. A novel programmable pulse generator with nanosecond resolution for pulsed electron paramagnetic resonance applications. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2008; 79:026106. [PMID: 18315338 DOI: 10.1063/1.2839398] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
A pulse programmer with nanosecond time resolution needed for time-domain electron paramagnetic resonance (EPR) spectroscopic applications is described. This unit uses commercially available timing and input-output port modules and control software developed in our laboratory. The pulse programmer is operated through a personal computer front panel graphic user interface (GUI) inputs to control pulse widths, delays, and the associated acquisition trigger timings. Based on these parameters, all other associated gate and trigger timings are internally generated automatically without the need to enter them explicitly. The excitation pulse widths were of nanosecond resolution while all other gate pulses can be incremented in steps of 20 ns without compromising spectrometer performance. In the current configuration, the pulse programmer permits generation of a single pulse or multiple pulse sequences for EPR imaging with minimal data entry via the front panel GUI.
Collapse
|
116
|
Hyodo F, Subramanian S, Devasahayam N, Murugesan R, Matsumoto K, Mitchell JB, Krishna MC. Evaluation of sub-microsecond recovery resonators for in vivo electron paramagnetic resonance imaging. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2008; 190:248-254. [PMID: 18042414 PMCID: PMC2258207 DOI: 10.1016/j.jmr.2007.11.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2007] [Revised: 10/16/2007] [Accepted: 11/02/2007] [Indexed: 05/25/2023]
Abstract
Time-domain (TD) electron paramagnetic resonance (EPR) imaging at 300MHz for in vivo applications requires resonators with recovery times less than 1 micros after pulsed excitation to reliably capture the rapidly decaying free induction decay (FID). In this study, we tested the suitability of the Litz foil coil resonator (LCR), commonly used in MRI, for in vivo EPR/EPRI applications in the TD mode and compared with parallel coil resonator (PCR). In TD mode, the sensitivity of LCR was lower than that of the PCR. However, in continuous wave (CW) mode, the LCR showed better sensitivity. The RF homogeneity was similar in both the resonators. The axis of the RF magnetic field is transverse to the cylindrical axis of the LCR, making the resonator and the magnet co-axial. Therefore, the loading of animals, and placing of the anesthesia nose cone and temperature monitors was more convenient in the LCR compared to the PCR whose axis is perpendicular to the magnet axis.
Collapse
|
117
|
Hyodo F, Murugesan R, Matsumoto KI, Hyodo E, Subramanian S, Mitchell JB, Krishna MC. Monitoring redox-sensitive paramagnetic contrast agent by EPRI, OMRI and MRI. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2008; 190:105-12. [PMID: 18006345 PMCID: PMC2258209 DOI: 10.1016/j.jmr.2007.10.013] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2007] [Revised: 10/16/2007] [Accepted: 10/18/2007] [Indexed: 05/07/2023]
Abstract
A comparative study of tissue redox-status imaging using commonly used redox sensitive nitroxides has been carried out using electron paramagnetic resonance imaging (EPRI), Overhauser magnetic resonance imaging (OMRI) and conventional T(1)-weighted magnetic resonance imaging, MRI. Imaging studies using phantoms of different nitroxides at different concentration levels showed that EPRI and OMRI sensitivities were found to be linearly dependent on line width of nitroxides up to 2 mM, and the enhancement in MRI intensity was linear up to 5 mM. The sensitivity and resolution of EPRI and OMRI images depended significantly on the line width of the nitroxides whereas the MRI images were almost independent of EPR line width. Reduction of the paramagnetic 3-carbamoyl-2,2,5,5-tetramethylpyrrolidine-1-oxyl (3CP) by ascorbic acid (AsA) to the diamagnetic by hydroxylamine was monitored from a sequence of temporal images, acquired using the three imaging modalities. The decay rates determined by all the three modalities were found to be similar. However the results suggest that T(1)-weighted MRI can monitor the redox status, in addition to providing detailed anatomical structure in a short time. Therefore, a combination of MRI with nitroxides as metabolically responsive contrast agents can be a useful technique for the in vivo imaging probing tissue redox status.
Collapse
|
118
|
Isenberg JS, Hyodo F, Pappan LK, Abu-Asab M, Tsokos M, Krishna MC, Frazier WA, Roberts DD. Blocking thrombospondin-1/CD47 signaling alleviates deleterious effects of aging on tissue responses to ischemia. Arterioscler Thromb Vasc Biol 2007; 27:2582-8. [PMID: 17916772 DOI: 10.1161/atvbaha.107.155390] [Citation(s) in RCA: 75] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
OBJECTIVE Decreased blood flow secondary to peripheral vascular disease underlies a significant number of chronic diseases that account for the majority of morbidity and mortality among the elderly. Blood vessel diameter and blood flow are limited by the matricellular protein thrombospondin-1 (TSP1) through its ability to block responses to the endogenous vasodilator nitric oxide (NO). In this study we investigate the role TSP1 plays in regulating blood flow in the presence of advanced age and atherosclerotic vascular disease. METHODS AND RESULTS Mice lacking TSP1 or CD47 show minimal loss of their resistance to ischemic injury with age and increased preservation of tissue perfusion immediately after injury. Treatment of WT and apolipoprotein E-null mice using therapeutic agents that decrease CD47 or enhance NO levels reverses the deleterious effects of age- and diet-induced vasculopathy and results in significantly increased tissue survival in models of ischemia. CONCLUSIONS With increasing age and diet-induced atherosclerotic vascular disease, TSP1 and its receptor CD47 become more limiting for blood flow and tissue survival after ischemic injury. Drugs that limit TSP1/CD47 regulation of blood flow could improve outcomes from surgical interventions in the elderly and ameliorate vascular complications attendant to aging.
Collapse
|
119
|
Soule BP, Hyodo F, Matsumoto KI, Simone NL, Cook JA, Krishna MC, Mitchell JB. Therapeutic and clinical applications of nitroxide compounds. Antioxid Redox Signal 2007; 9:1731-43. [PMID: 17665971 DOI: 10.1089/ars.2007.1722] [Citation(s) in RCA: 101] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Nitroxide compounds have been used for many years as biophysical tools, but only during the past 15-20 years have the many interesting biochemical interactions been discovered and harnessed for therapeutic applications. By modifying oxidative stress and altering the redox status of tissues, nitroxides have the ability to interact with and alter many metabolic processes. This interaction can be exploited for therapeutic and research use, including protection against ionizing radiation, as probes in functional magnetic resonance imaging, cancer prevention and treatment, control of hypertension and weight, and protection from damage resulting from ischemia/reperfusion injury. Although much remains to be done, many applications have been well studied, and some are presently being tested in clinical trials. The therapeutic and research uses of nitroxides are reviewed here, with a focus on the progress from initial development to modern, state-of-the art trials.
Collapse
|
120
|
Hama Y, Matsumoto KI, Murugesan R, Subramanian S, Devasahayam N, Koscielniak JW, Hyodo F, Cook JA, Mitchell JB, Krishna MC. Continuous wave EPR oximetric imaging at 300 MHz using radiofrequency power saturation effects. Antioxid Redox Signal 2007; 9:1709-16. [PMID: 17696765 DOI: 10.1089/ars.2007.1720] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A novel continuous wave (CW), radiofrequency (RF), electron paramagnetic resonance (EPR) oximetric imaging technique is proposed, based on the influence of oxygen concentration on the RF power saturation of the EPR resonance. A linear relationship is demonstrated between the partial oxygen pressure (pO(2)) and the normalized signal intensity (I(N)), defined as, I(N) = (I(HP) - I(LP))/I(LP), where I(LP) and I(HP) refer to signal intensities at low (P(L)) and high (P(H)) RF power levels, respectively. A formula for the determination of pO(2), derived on the basis of the experimental results, reliably estimated various oxygen concentrations in a five-tube phantom. This new technique was time-efficient and also avoided the missing angle problem associated with conventional spectral-spatial CW EPR oximetric imaging. In vivo power saturation oximetric imaging in a tumor bearing mouse clearly depicted the hypoxic foci within the tumor.
Collapse
|
121
|
Cotrim AP, Hyodo F, Matsumoto KI, Sowers AL, Cook JA, Baum BJ, Krishna MC, Mitchell JB. Differential radiation protection of salivary glands versus tumor by Tempol with accompanying tissue assessment of Tempol by magnetic resonance imaging. Clin Cancer Res 2007; 13:4928-33. [PMID: 17699873 DOI: 10.1158/1078-0432.ccr-07-0662] [Citation(s) in RCA: 86] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE The nitroxide free radical, Tempol, was evaluated for potential differential radiation protection of salivary glands and tumor using fractionated radiation. Mechanistic information was explored by monitoring the presence and bioreduction of Tempol in both tissues noninvasively by magnetic resonance imaging (MRI). EXPERIMENTAL DESIGN Female C3H mice were immobilized using custom-made Lucite jigs for localized irradiation (five daily fractions) either to the oral cavity or tumor-bearing leg. Tempol (275 mg/kg) was administered (i.p.) 10 min before each radiation fraction. Salivary gland damage was assessed 8 weeks after radiation by measuring pilocarpine-mediated saliva output. Tumor growth was assessed by standard radiation regrowth methods. Dynamic T1-weighted magnetic resonance scans were acquired before and after Tempol injection using a 4.7T animal MRI instrument. RESULTS Tempol treatment was found to protect salivary glands significantly against radiation damage (approximately 60% improvement); whereas no tumor protection was observed. Intracellular reduction of Tempol to the nonradioprotective hydroxylamine as assessed by MRI was 2-fold faster in tumor compared with salivary glands or muscle. CONCLUSIONS Tempol provided salivary gland radioprotection and did not protect tumor, consistent with the hypothesis that differential radioprotection by Tempol resides in faster reduction to the nonradioprotective hydroxylamine in tumor compared with normal tissues. The unique paramagnetic properties of Tempol afforded noninvasive MRI monitoring of dynamic changes of Tempol levels in tissue to support the finding. These data support further development and consideration of Tempol for human clinical trials as a selective protector against radiation-induced salivary gland damage.
Collapse
|
122
|
Matsumoto KI, Subramanian S, Murugesan R, Mitchell JB, Krishna MC. Spatially resolved biologic information from in vivo EPRI, OMRI, and MRI. Antioxid Redox Signal 2007; 9:1125-41. [PMID: 17571957 DOI: 10.1089/ars.2007.1638] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
EPR spectroscopy can give biologically important information, such as tissue redox status, pO2, pH, and microviscosity, based on variation of EPR spectral characteristics (i.e., intensity, linewidth, hyperfine splitting, and spectral shape of free radical probes. EPR imaging (EPRI) can obtain 1D-3D spatial distribution of such spectral components using several combinations of magnetic field gradients. Overhauser enhanced MRI (OMRI) is a double-resonance technique of electron and nuclear spins. Because the Overhauser enhancement depends on transverse relaxation rate of the electron spin, OMRI can provide pO2 information indirectly, along with a high-resolution MR image. MRI can also indirectly detect paramagnetic behaviors of free radical contrast agents. Imaging techniques and applications relating to paramagnetic species (i.e., EPRI, OMRI, and MRI) have the potential to obtain maximally 5D information (i.e., 3D spatial + 1D spectral + 1D temporal dimensions, theoretically). To obtain suitable dimensionality, several factors, such as the EPR spectral information, spatial resolution, temporal resolution, will have to be taken into account. For this review, the EPRI, OMRI, and MRI applications for the study biological systems were evaluated for researchers to apply the method of choice and the mode of measurements to specific experimental systems.
Collapse
|
123
|
Soule BP, Hyodo F, Matsumoto KI, Simone NL, Cook JA, Krishna MC, Mitchell JB. The chemistry and biology of nitroxide compounds. Free Radic Biol Med 2007; 42:1632-50. [PMID: 17462532 PMCID: PMC1991293 DOI: 10.1016/j.freeradbiomed.2007.02.030] [Citation(s) in RCA: 381] [Impact Index Per Article: 22.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2006] [Revised: 02/21/2007] [Accepted: 02/27/2007] [Indexed: 02/04/2023]
Abstract
Cyclic nitroxides are a diverse group range of stable free radicals that have unique antioxidant properties. Because of their ability to interact with free radicals, they have been used for many years as biophysical tools. During the past 15-20 years, however, many interesting biochemical interactions have been discovered and harnessed for therapeutic applications. Biologically relevant effects of nitroxides have been described, including their ability to degrade superoxide and peroxide, inhibit Fenton reactions, and undergo radical-radical recombination. Cellular studies defined the activity of nitroxides in vitro. By modifying oxidative stress and altering the redox status of tissues, nitroxides have been found to interact with and alter many metabolic processes. These interactions can be exploited for therapeutic and research use, including protection against ionizing radiation, as probes in functional magnetic resonance imaging, cancer prevention and treatment, control of hypertension and weight, and protection from damage resulting from ischemia/reperfusion injury. Although much remains to be done, many applications have been well studied and some are currently being tested in clinical trials. The therapeutic and research uses of nitroxide compounds are reviewed here with a focus on the progress from initial development to modern trials.
Collapse
|
124
|
Subramanian S, Koscielniak JW, Devasahayam N, Pursley RH, Pohida TJ, Krishna MC. A new strategy for fast radiofrequency CW EPR imaging: direct detection with rapid scan and rotating gradients. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2007; 186:212-9. [PMID: 17350865 PMCID: PMC2084379 DOI: 10.1016/j.jmr.2007.01.023] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2006] [Revised: 01/21/2007] [Accepted: 01/27/2007] [Indexed: 05/05/2023]
Abstract
Rapid field scan on the order of T/s using high frequency sinusoidal or triangular sweep fields superimposed on the main Zeeman field, was used for direct detection of signals without low-frequency field modulation. Simultaneous application of space-encoding rotating field gradients have been employed to perform fast CW EPR imaging using direct detection that could, in principle, approach the speed of pulsed FT EPR imaging. The method takes advantage of the well-known rapid-scan strategy in CW NMR and EPR that allows arbitrarily fast field sweep and the simultaneous application of spinning gradients that allows fast spatial encoding. This leads to fast functional EPR imaging and, depending on the spin concentration, spectrometer sensitivity and detection band width, can provide improved temporal resolution that is important to interrogate dynamics of spin perfusion, pharmacokinetics, spectral spatial imaging, dynamic oxymetry, etc.
Collapse
|
125
|
Devasahayam N, Subramanian S, Murugesan R, Hyodo F, Matsumoto KI, Mitchell JB, Krishna MC. Strategies for improved temporal and spectral resolution in in vivo oximetric imaging using time-domain EPR. Magn Reson Med 2007; 57:776-83. [PMID: 17390350 DOI: 10.1002/mrm.21194] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
A radiofrequency (RF) time-domain electron paramagnetic resonance (EPR) instrument operating at 300, 600, and 750 MHz was used to image tumor hypoxia with high spatial and temporal resolution. A high-speed signal-averaging Peripheral Component Interconnect (PCI) board with flexibility in the input signal level and the number of digitized samples per free induction decay (FID) was incorporated into the receive arm of the spectrometer. This enabled effective and fast averaging of FIDs. Modification of the phase-encoding protocol, and replacement of the General Purpose Interface Bus (GPIB)-based handshake with a PCI-based D/A board for direct control of the gradient amplifier decreased the gradient settling and communication overhead times by nearly two orders of magnitude. Cyclically-ordered phase sequence (CYCLOPS) phase cycling was implemented to correct for pulse imperfections and cancel out unwanted constant signals. These upgrades considerably enhanced the performance of the imager in terms of image collection time, sensitivity, and temporal resolution. We demonstrated this by collecting a large number of 2D images successively and rapidly. The results show that it is feasible to achieve accurate, 2D pO(2) maps of tumor hypoxia with 1-mm(2) resolution and minimal artifacts using a set of multigradient images within an acceptable measuring time of about 3 s, and 3D maps can be obtained in less than 1 min.
Collapse
|