101
|
Banerjee R, Nag S, Samuel S, Fraser HL. Laser-deposited Ti-Nb-Zr-Ta orthopedic alloys. J Biomed Mater Res A 2006; 78:298-305. [PMID: 16637044 DOI: 10.1002/jbm.a.30694] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The complex quaternary Ti-35Nb-7Zr-5Ta orthopedic alloy has been successfully deposited from a powder feedstock consisting of a blend of elemental titanium, niobium, zirconium, and tantalum powders, using the laser engineered net-shaping (LENStrade mark) process. In the as laser-deposited form, these alloys exhibit a substantially higher tensile strength as compared with more conventionally processed counterparts of similar composition, while maintaining excellent ductility and a low modulus. Furthermore, the as-deposited alloys appear to exhibit a <001> texture, with a substantially large number of grains of the beta phase aligning one of their <001> axes nearly normal to the substrate or parallel to the growth direction. The microstructure of the as-deposited as well as tensile-tested alloys have been characterized in detail using scanning electron microscopy (SEM), orientation microscopy (OM), and transmission electron microscopy (TEM). Formation of a high density of shear bands, possibly arising from slip localization due to precipitates of the omega phase in the beta matrix, is clearly evident in the tensile-tested sample. The enhanced tensile strength and low modulus in these laser-deposited alloys coupled with the ability to form near-net shape components makes LENS an attractive processing technology for orthopedic implants.
Collapse
|
102
|
Eisenbarth E, Velten D, Müller M, Thull R, Breme J. Nanostructured niobium oxide coatings influence osteoblast adhesion. J Biomed Mater Res A 2006; 79:166-75. [PMID: 16788971 DOI: 10.1002/jbm.a.30823] [Citation(s) in RCA: 79] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The interaction of osteoblasts was correlated to the roughness of nanosized surface structures of Nb(2)O(5) coatings on polished CP titanium grade 2. Nb(2)O(5) sol-gel coatings were selected as a model surface to study the interaction of osteoblasts with nanosized surface structures. The surface roughness was quantified by determination of the average surface finish (Ra number) by means of atomic force microscopy. Surface topographies with Ra = 7, 15, and 40 nm were adjusted by means of the annealing process parameters (time and temperature) within a sol-gel coating procedure. The observed osteoblast migration was fastest on smooth surfaces with Ra = 7 nm. The adhesion strength, spreading area, and collagen-I synthesis showed the best results on an intermediate roughness of Ra = 15 nm. The surface roughness of Ra = 40 nm was rather peaked and reduced the speed of cell reactions belonging to the adhesion process.
Collapse
|
103
|
Jenko D, Bencan A, Malic B, Holc J, Kosec M. Electron microscopy studies of potassium sodium niobate ceramics. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2005; 11:572-80. [PMID: 17481336 DOI: 10.1017/s1431927605050683] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2004] [Accepted: 06/27/2005] [Indexed: 05/15/2023]
Abstract
Using electron microscopy, K0.5Na0.5NbO3 (KNN) ceramics sintered at 1030 degrees C for 8 h and 1100 degrees C for 2 and 24 h was studied. The scanning electron microscopy and X-ray spectrometry revealed that the materials consisted of a matrix phase in which the (Na+K)/Nb ratio corresponded closely to the nominal composition and a small amount of Nb-rich secondary phase. A bimodal microstructure of cube-shaped grains was revealed in the fracture and thermally-etched surfaces of the KNN. In the ceramics sintered at 1100 degrees C, the larger grains (up to 30 mum across), contained angular trapped pores. The transmission electron microscopy analysis revealed that the crystal planes of the grains bordering the intragranular pore faces were of the {100} family with respect to the simple perovskite cell. Ferroelectric domains were observed in the grains of this material.
Collapse
|
104
|
Bourne RB, Barrack R, Rorabeck CH, Salehi A, Good V. Arthroplasty options for the young patient: Oxinium on cross-linked polyethylene. Clin Orthop Relat Res 2005; 441:159-67. [PMID: 16330999 DOI: 10.1097/01.blo.0000193813.08458.e2] [Citation(s) in RCA: 55] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Our purpose was to determine whether metal femoral heads scratch with in vivo use, to characterize the scratching that occurs, and to determine whether this scratching affected polyethylene wear. Assessment of 133 consecutive retrieved femoral heads showed that metal femoral heads do scratch with in vivo use, that cobalt-chromium femoral heads are more scratch resistant than titanium alloy heads, and that scratching seems to be time dependent. Profilmetry studies showed that all roughness parameters (average roughness, maximum peak to lowest valley distance, mean peak height above the mean surface line, estimate of small peaks above the main plateau of the surface, and estimate of the depth of the valleys below the mean plateau of the surface with the exception of the symmetry of the profile about its mean line) showed increased roughness with time of use. Cobalt-chromium and Oxinium femoral heads were damaged in a dislocation model. Assessment of these femoral heads in a wear simulator revealed that against conventional polyethylene, a damaged Oxinium femoral head had no more wear than a new cobalt-chromium articulation on the same polyethylene (36.5/million cycles versus 38.4 mm/million). Against cross-linked polyethylene, a damaged Oxinium femoral head had minimal wear (1.5 mm cubed per Mc).
Collapse
|
105
|
Abstract
In this study, the grindability of cast magnetic alloys (Fe-Pt-Nb magnetic alloy and magnetic stainless steel) was evaluated and compared with that of conventional dental casting alloys (Ag-Pd-Au alloy, Type 4 gold alloy, and cobalt-chromium alloy). Grindability was evaluated in terms of grinding rate (i.e., volume of metal removed per minute) and grinding ratio (i.e., volume ratio of metal removed compared to wheel material lost). Solution treated Fe-Pt-Nb magnetic alloy had a significantly higher grinding rate than the aged one at a grinding speed of 750-1500 m x min(-1). At 500 m x min(-1), there were no significant differences in grinding rate between solution treated and aged Fe-Pt-Nb magnetic alloys. At a lower speed of 500 m x min(-1) or 750 m x min(-1), it was found that the grinding rates of aged Fe-Pt-Nb magnetic alloy and stainless steel were higher than those of conventional casting alloys.
Collapse
|
106
|
Takagi T, Sutou Y, Kainuma R, Yamauchi K, Ishida K. Effect of prestrain on martensitic transformation in a Ti46.4Ni47.6Nb6.0 superelastic alloy and its application to medical stents. J Biomed Mater Res B Appl Biomater 2005; 76:179-83. [PMID: 16222697 DOI: 10.1002/jbm.b.30415] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The effect of applied strain on martensitic transformation in a superelastic Ti(46.4)Ni(47.6)Nb(6.0) alloy at room temperature was investigated by tensile tests, differential scanning calorimetry measurements, and X-ray diffraction. Reverse transformation starting (A(s)) and finishing (A(f)) temperatures increased with the application of tensile-strain over 13%, the undeformed specimen showing A(s) = -29.2 degrees C and A(f) = 17.9 degrees C, while the 13% predeformed alloy exhibited A(s) = 37.1 degrees C and A(f) = 40.2 degrees C. Furthermore, the values of the A(s) and A(f) for the predeformed alloy almost recovered to those of the undeformed alloy when heated to about 42 degrees C and then showed superelasticity again at room temperature. This characteristic is significant for application in sensors, actuators, and medical devices. Especially, medical stents with such qualities show promise as a new class of self-expandable stents with both excellent mountability and deliverability.
Collapse
|
107
|
Oliveira NTC, Biaggio SR, Rocha-Filho RC, Bocchi N. Electrochemical studies on zirconium and its biocompatible alloys Ti-50Zr at.% and Zr-2.5Nb wt.% in simulated physiologic media. J Biomed Mater Res A 2005; 74:397-407. [PMID: 15983989 DOI: 10.1002/jbm.a.30352] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Different electrochemical studies were carried out for Zr and its biocompatible alloys Ti-50Zr at.% and Zr-2.5Nb wt.% in solutions simulating physiologic media, Ringer and PBS (phosphate buffered saline) solutions. The results from rest-potential measurements showed that the three materials are spontaneously passivated in both solutions and that the Ti-50Zr alloy has the greatest tendency for spontaneous oxide formation. Some corrosion parameters (such as the pitting and repassivation potentials) were obtained via cyclic voltammetry in both solutions, revealing that the Ti-50Zr has the best corrosion protection while Zr has the worst. On the other hand, the pre-anodization (up to 8 V vs. SCE) of the alloys in a 0.15 mol/L Na2SO4 solution led to a significant improvement in their protection against pitting corrosion when exposed to the Ringer solution. Elemental analyses by EDX showed that during pitting corrosion, there is no preferential corrosion of any of the alloying elements (Zr, Ti, Nb).
Collapse
|
108
|
Qiu CL, Liu L, Sun M, Zhang SM. The effect of Nb addition on mechanical properties, corrosion behavior, and metal-ion release of ZrAlCuNi bulk metallic glasses in artificial body fluid. J Biomed Mater Res A 2005; 75:950-6. [PMID: 16206266 DOI: 10.1002/jbm.a.30502] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Bulk metallic glasses (BMGs) of Zr(65 - x)Nb(x)- Cu(17.5)Ni(10)Al(7.5) with Nb = 0, 2, and 5 at % were prepared by copper mold casting. Compression tests reveal that the two BMGs containing Nb exhibited superior strength and plasticity to the base alloy. The corrosion behavior of the alloys obtained was investigated in artificial body fluid by electrochemical measurements. It was found that the addition of Nb significantly enhanced the corrosion resistance of the Zr-based BMG, as indicated by a remarkable increase in corrosion potential and pitting potential. XPS analysis revealed that the passive film formed after anodic polarization was enriched in aluminum oxide and depleted in phosphate ions for the BMGs containing Nb, which accounts for the improvement of corrosion resistance. On the other hand, metal-ion release of different BMGs were determined in PPb (ng/mL) level with inductively coupled plasma mass spectrometry (ICP-MS) after being immersed in artificial body fluid at 37 degrees C for 20 days. It was found that the addition of Nb considerably reduced the ion release of all kinds of metals of the base system. This is probably attributed to the promoting effect of Nb on a rapid formation of highly protective film.
Collapse
|
109
|
Buckley KR, Jivan S, Ruth TJ. Improved yields for the in situ production of [11C]CH4 using a niobium target chamber. Nucl Med Biol 2004; 31:825-7. [PMID: 15246376 DOI: 10.1016/j.nucmedbio.2004.03.007] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2004] [Revised: 03/01/2004] [Accepted: 03/16/2004] [Indexed: 11/29/2022]
Abstract
The in situ production of [11C]CH4 using a niobium metal target chamber is described. Improved yields are observed in comparison to the previously reported aluminum conical target under similar conditions of beam energy and current. An empirical expression is proposed that quantifies the loss of yield as a function of irradiation time.
Collapse
|
110
|
Ban S. Effect of alkaline treatment of pure titanium and its alloys on the bonding strength of dental veneering resins. J Biomed Mater Res A 2003; 66:138-45. [PMID: 12833440 DOI: 10.1002/jbm.a.10566] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Commercially pure titanium (cpTi), Ti6Al4V, an experimental beta-type titanium (Ti 53.4 wt%, Nb 29 wt %, Ta 13 wt %, and Zr 4.6 wt %), and 12% AuPdAg alloy plates were sandblasted, cleaned in water, and dried. cpTi plates were treated with nine alkaline treatments that differed in the type of alkali, alkaline concentration, soaking temperature, soaking time, and heating temperature. cpTi plates that were only sandblasted or sandblasted and oxidized at 600 degrees C for 1 h in air were also prepared. Finally, the bonding strengths of 11 kinds of surface-treated cpTi to resin were measured using a pull-shear bonding method after immersion in physiologic saline solution at 37 degrees C for 24 h. The bonds of the standard alkaline-treated cpTi and two titanium alloys to resins were 1.5-1.9 times stronger than those of sandblasted specimens (p < 0.01), but no significant effects of the alkaline treatment were observed on the 12% AuPdAg alloy. The greatest bonding strengths were found for cpTi treated with NaOH and KOH and then heated at 600 degrees C (p < 0.01). In conclusion, alkaline treatment is a simple, effective surface modification of titanium that improves bonding to veneering resin.
Collapse
|
111
|
Aristizábal O, Turnbull DH. 44-MHz LiNbO3 transducers for UBM-guided Doppler ultrasound. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2003; 50:623-630. [PMID: 12839174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
In the post genome-sequencing era, physiological phenotyping of genetically engineered mice is critical to further our understanding of the functional consequences of specific genetic defects. We have developed a 40-50 MHz ultrasound biomicroscopy-(UBM) guided, pulsed Doppler system for the sensitive detection of in vivo blood velocity waveforms in the mouse embryonic cardiovascular system. Our approach uses separate transducers for simultaneous imaging and Doppler blood flow measurements. To this end, unfocused, air-backed lithium niobate (LiNbO3) transducers provide sensitive Doppler detection and the flexibility of adjusting the axial position of the pulsed Doppler sample volume over many millimeters depth range of the collimated ultrasound beam. In this paper we describe the fabrication and characterization of the electromechanical and ultrasonic beam properties of 44-MHz LiNbO3 Doppler transducers. We further demonstrate the utility of these Doppler transducers for interrogating blood vessels such as the dorsal aorta over a range of mouse embryonic stages and axial range-gate depths.
Collapse
|
112
|
Ashizawa H, Ohara S, Yamaguchi S, Takahashi M, Endo M, Nanri K, Fujioka T, Tittel FK. Performance characteristics of narrow linewidth fiber laser pumped mid-IR difference frequency mixing light source for methane detection. JAPANESE JOURNAL OF APPLIED PHYSICS 2003; 42:1263-1267. [PMID: 12959140 DOI: 10.1143/jjap.42.1263] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
A high-power, narrow-linewidth Yb fiber laser with a fiber Bragg grating (FBG) pumped difference frequency generation (DFG) in a periodically poled lithium niobate (PPLN) crystal was investigated in detail. A mid-IR power of approximately 2.3 microW at 3.3 micrometers with a slope efficiency of 0.85 mW/W2 was achieved. A Doppler-broadened absorption spectrum of CH4 at 3038.497 cm-1 (3.2911 micrometers) was obtained with a 0.1-m long-gas cell at a pressure of 133 Pa. The linewidth of the DFG source was evaluated to be less than 96 MHz from the observed spectral linewidth. Real-time monitoring of CH4 (approximately 1.78 ppm) in ambient air in a multipass cell which has an optical path length of 10 m was also demonstrated.
Collapse
|
113
|
Shui Y, Lin JM, Wu H, Wang N, Chen H. Optimization of single-phase, unidirectional transducers using three fingers per period. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2002; 49:1617-1621. [PMID: 12546142 DOI: 10.1109/tuffc.2002.1159840] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Electrode width controlled (EWC) single-phase, unidirectional transducers (SPUDT) is widely used for low loss surface acoustic wave (SAW) filters. The insertion loss and fractional bandwidth of the filters are strongly related to the reflectivity of EWC cells. In order to achieve wide band and low loss simultaneously, it is necessary to obtain higher reflectivity. The relationship between geometrical configuration of EWC cells and reflection coefficient, (and transduction coefficient as well) is studied. Simulation results indicate that the reflectivity of the EWC SPUDT cell could exceed 5% on a 128 degrees Y-X lithium niobate (LiNbO3) substrate. Using such structure, low loss SPUDT test filters without weighting are fabricated. The measured 3 dB bandwidth is 3.9% and the insertion loss is 2.9 dB. The theoretical calculation is verified by the experiment.
Collapse
|
114
|
Joshi SG, Zaitsev BD, Kuznetsova IE. Reflection of plate acoustic waves produced by a periodic array of mechanical load strips or grooves. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2002; 49:1730-1734. [PMID: 12546152 DOI: 10.1109/tuffc.2002.1159850] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The reflection of fundamental acoustic waves propagating in a thin piezoelectric plate by a periodic array of conducting strips of finite thickness or grooves has been theoretically and experimentally investigated. The analysis has shown that electrical shorting and mass loading affect the relationship of neighboring region impedances in a contrary manner. In some cases, these effects are comparable, and there exists a certain strip thickness for each piezoactive fundamental plate mode at which the reflection coefficient can become zero. A high efficiency of grooved reflector for plate acoustic waves was theoretically revealed. Experimental results for mass loading and grooved reflections, which have been obtained for an SH0 wave propagating in the Y-X lithium niobate plate, are in a good agreement with the theory. They show a high efficiency of such reflectors and confirm an opportunity of using a model based on equivalent circuit for the analysis of their operation. Investigations indicate that nearly 100% reflection of the SH0 wave in the lithium niobate plate can be obtained with the use of a mass loading reflector containing 10 silver strips of thickness d/h = 0.08 or a grooved reflector containing eight grooves of depth d/h = 0.25. Here h is the plate thickness and d is the reflector thickness or depth.
Collapse
|
115
|
Gnewuch H, Pannell CN. Monolithic bulk shear-wave acousto-optic tunable filter. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2002; 49:1635-1640. [PMID: 12546145 DOI: 10.1109/tuffc.2002.1159843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
We demonstrate a monolithic bulk shear-wave acousto-optic tunable filter combining a piezoelectric transducer array and the acoustic interaction medium in a single crystal. An X-propagating acoustic longitudinal wave is excited in the "crossed-field" scheme by an rf-Ey-field in a chirped acoustic superlattice formed by domain-inversion in lithium niobate (LiNbO3). The acoustic longitudinal wave is efficiently (97.5%) converted at a mechanically free boundary into a Y-propagating acoustic slow-shear wave that couples collinearly propagating e- and o-polarized optical waves. A relative conversion efficiency of 80%/W was measured at 980 nm.
Collapse
|
116
|
Richter D, Fried A, Wert BP, Walega JG, Tittel FK. Development of a tunable mid-IR difference frequency laser source for highly sensitive airborne trace gas detection. APPLIED PHYSICS. B, LASERS AND OPTICS 2002; 75:281-288. [PMID: 12599397 DOI: 10.1007/s00340-002-0948-y] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The development of a compact tunable mid-IR laser system at 3.5 micrometers for quantitative airborne spectroscopic trace gas absorption measurements is reported. The mid-IR laser system is based on difference frequency generation (DFG) in periodically poled LiNbO3 and utilizes optical fiber amplified near-IR diode and fiber lasers as pump sources operating at 1083 nm and 1562 nm, respectively. This paper describes the optical sensor architecture, performance characteristics of individual pump lasers and DFG, as well as its application to wavelength modulation spectroscopy employing an astigmatic Herriott multi-pass gas absorption cell. This compact system permits detection of formaldehyde with a minimal detectable concentration (1 sigma replicate precision) of 74 parts-per-trillion by volume (pptv) for 1 min of averaging time and was achieved using calibrated gas standards, zero air background and rapid dual-beam subtraction. This corresponds to a pathlength-normalized replicate fractional absorption sensitivity of 2.5 x 10-(10 )cm-1.
Collapse
|
117
|
Pires do Rio MA, Amaral ECS, Fernandes HM, Rochedo ERR. Environmental radiological impact associated with non-uranium mining industries: a proposal for screening criteria. JOURNAL OF ENVIRONMENTAL RADIOACTIVITY 2002; 59:1-17. [PMID: 11859844 DOI: 10.1016/s0265-931x(01)00023-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Niobium, phosphate, coal and gold mining facilities have been selected as case studies with the aim of identifying possible sources of radiological impact during and after cessation of industrial operations. The results have shown that acid drainage, as well as chemical processing of mineral ores, constitute relevant impact indicators for present-day and future scenarios. The possible use of solid wastes abandoned at the end of the operations represents a long-term radiological concern. Therefore, it is necessary that Brazilian legislation for environmental licensing be revised taking into account the potential environmental and radiological impacts caused by these industries and establishing remedial procedures for waste storage areas in the existing sites. The indicators developed and procedures carried out can be used in screening for decisions on the adoption of regulatory requirements for practices at such types of installations.
Collapse
|
118
|
[Various alloys used in orthodontics]. Orthod Fr 2001; 72:271-8. [PMID: 11678015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
|
119
|
Matsuoka N, Yamaguchi S, Nanri K, Fujioka T, Richter D, Tittel FK. Yb fiber laser pumped mid-IR source based on difference frequency generation and its application to ammonia detection. JAPANESE JOURNAL OF APPLIED PHYSICS 2001; 40 Pt 1:625-628. [PMID: 11676447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
A Yb fiber laser pumped cw narrow-linewidth tunable mid-IR source based on a difference frequency generation (DFG) in a periodically poled LiNbO3 (PPLN) crystal for trace gas detection was demonstrated. A high power Yb fiber laser and a distributed feedback (DFB) laser diode were used as DFG pump sources. This source generated mid-IR at 3 microns with a powers of ~2.5 microW and a spectral linewidth of less than 30 MHz. A frequency tuning range of 300 GHz (10 cm-1) was obtained by varying the current and temperature of the DFB laser diode. A high-resolution NH3 absorption Doppler-broadened spectrum at 3295.4 cm-1 (3.0345 microns) was obtained at a cell pressure of 27 Pa from which a detection sensitivity of 24 ppm m was estimated.
Collapse
|
120
|
Berger J, Petermann K, Fähling H, Wust P. Calibrated electro-optic E-field sensors for hyperthermia applications. Phys Med Biol 2001; 46:399-411. [PMID: 11229722 DOI: 10.1088/0031-9155/46/2/309] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
E-field measurements are an important task for the investigation of newly developed hyperthermia applicators as well as for online control of hyperthermia treatments. Compact and non-perturbing integrated optical E-field sensors based on LiNbO3 as well as optical E-field sensors based on infrared emitting diodes and light bulbs are suitable for nearfield measurements of hyperthermia antennas. In order to investigate their properties a calibration cell with transverse electromagnetic (TEM) waves has been constructed. By using this cell, calibration curves and directional patterns for all sensors have been measured. Due to the threshold behaviour of the IRED and light bulb sensor, only the LiNbO3 sensor is capable of measuring weak fields inside an applicator or a homogeneous phantom.
Collapse
|
121
|
Rehle D, Leleux D, Erdelyi M, Tittel F, Fraser M, Friedfeld S. Ambient formaldehyde detection with a laser spectrometer based on difference-frequency generation in PPLN. APPLIED PHYSICS. B, LASERS AND OPTICS 2001; 72:947-952. [PMID: 12484352 DOI: 10.1007/s003400100549] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
A laser spectrometer based on difference-frequency generation in periodically poled LiNbO3 (PPLN) has been used to quantify atmospheric formaldehyde with a detection limit of 0.32 parts per billion in a given volume (ppbV) using specifically developed data-processing techniques. With state-of-the-art fiber-coupled diode-laser pump sources at 1083 nm and 1561 nm, difference-frequency radiation has been generated in the 3.53-micrometers (2832-cm-1) spectral region. Formaldehyde in ambient air in the 1- to 10-ppb V range has been detected continuously for nine and five days at two separate field sites in the Greater Houston area operated by the Texas Natural Resource Conservation Commission (TNRCC) and the Houston Regional Monitoring Corporation (HRM). The acquired spectroscopic data are compared with results obtained by a well-established wet-chemical o-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA) technique.
Collapse
|
122
|
Piquette JC, Smith RC. Analysis and comparison of four anhysteretic polarization models for lead magnesium niobate. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2000; 108:1651-1662. [PMID: 11051493 DOI: 10.1121/1.1310670] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Four anhysteretic polarization models that have been used in the literature to evaluate data acquired from lead magnesium niobate (PMN) are analyzed and compared. Derivations of two of the models from assumed spatial distributions of dipole energy states, using first physical principles, are presented. A third model is derived from a suitable integral averaging calculation. These derivations are used as the basis for developing an integral equation for determining an energy-state distribution that produces a fourth model, which was not originally formulated in terms of an assumed distribution. A new polarization function is also presented. Excellent approximations to each of the four polarization functions of interest can be deduced from this new polarization function by adjusting the numerical value of just a single parameter. An application of two of the models to data is presented. It is shown that it can be necessary to consider a sample to be an admixture of two distinct species of poles, in the sense that two polarization functions must be added together in order to accommodate the data.
Collapse
|
123
|
Zeisler SK, Becker DW, Pavan RA, Moschel R, Rühle H. A water-cooled spherical niobium target for the production of [18F]fluoride. Appl Radiat Isot 2000; 53:449-53. [PMID: 10972152 DOI: 10.1016/s0969-8043(99)00254-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
A new automated target system for the routine production of [18F]fluoride from (18)O-enriched water has been constructed. It consists of a small spherical niobium target chamber mounted into a special holder, which provides rapid cooling by water flow around the sphere. The target is irradiated with 21 MeV protons; the incident energy in the target chamber is 13 MeV. The system is operated without external over-pressure and has been tested for beam currents up to 50 microA. 95% of the theoretical yield of [18F]fluoride has been extracted and used for the synthesis of [18F]2-fluoro-2-deoxy-D-glucose.
Collapse
|
124
|
Polissar NL, Stanford DC, Glenny RW. The 400 microsphere per piece "rule" does not apply to all blood flow studies. Am J Physiol Heart Circ Physiol 2000; 278:H16-25. [PMID: 10644579 DOI: 10.1152/ajpheart.2000.278.1.h16] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Microsphere experiments are useful in measuring regional organ perfusion as well as heterogeneity of blood flow within organs and correlation of perfusion between organ pieces at different time points. A 400 microspheres/piece "rule" is often used in planning experiments or to determine whether experiments are valid. This rule is based on the statement that 400 microspheres must lodge in a region for 95% confidence that the observed flow in the region is within 10% of the true flow. The 400 microspheres precision rule, however, only applies to measurements of perfusion to a single region or organ piece. Examples, simulations, and an animal experiment were carried out to show that good precision for measurements of heterogeneity and correlation can be obtained from many experiments with <400 microspheres/piece. Furthermore, methods were developed and tested for correcting the observed heterogeneity and correlation to remove the Poisson "noise" due to discrete microsphere measurements. The animal experiment shows adjusted values of heterogeneity and correlation that are in close agreement for measurements made with many or few microspheres/piece. Simulations demonstrate that the adjusted values are accurate for a variety of experiments with far fewer than 400 microspheres/piece. Thus the 400 microspheres rule does not apply to many experiments. A "rule of thumb" is that experiments with a total of at least 15,000 microspheres, for all pieces combined, are very likely to yield accurate estimates of heterogeneity. Experiments with a total of at least 25,000 microspheres are very likely to yield accurate estimates of correlation coefficients.
Collapse
|
125
|
Tittel FK, Lancaster DG, Richter D. Novel diode laser-based sensors for gas sensing applications. LASER PHYSICS 2000; 10:348-354. [PMID: 12143895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The development of compact spectroscopic gas sensors and their applications to environmental sensing will be described. These sensors employ mid-infrared difference-frequency generation (DFG) in periodically poled lithium niobate (PPLN) crystals pumped by two single-frequency solid state lasers such as diode lasers, diode-pumped solid state, and fiber lasers. Ultrasensitive, highly selective, and real-time measurements of several important atmospheric trace gases, including carbon monoxide, nitrous oxide, carbon dioxide, formaldehyde [correction of formaldehye], and methane, have been demonstrated.
Collapse
|