126
|
Ding J, Zhou P, Guo W, Su B. Confined Electrochemiluminescence Generation at Ultra-High-Density Gold Microwell Electrodes. Front Chem 2021; 8:630246. [PMID: 33575249 PMCID: PMC7870482 DOI: 10.3389/fchem.2020.630246] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Accepted: 12/17/2020] [Indexed: 12/02/2022] Open
Abstract
Electrochemiluminescence (ECL) imaging analysis based on the ultra-high-density microwell electrode array (UMEA) has been successfully used in biosensing and diagnostics, while the studies of ECL generation mechanisms with spatial resolution remain scarce. Herein we fabricate a gold-coated polydimethylsiloxane (PDMS) UMEA using electroless deposition method for the visualization of ECL reaction process at the single microwell level in conjunction with using microscopic ECL imaging technique, demonstrating that the microwell gold walls are indeed capable of enhancing the ECL generation. For the classical ECL system involving tris(2,2′-bipyridyl)ruthenium (Ru(bpy)32+) and tri-n-propylamine (TPrA), the ECL image of a single microwell appears as a surface-confined ring, indicating the ECL intensity generated inside the well is much stronger than that on the top surface of UMEA. Moreover, at a low concentration of Ru(bpy)32+, the ECL image remains to be ring-shaped with the increase of exposure time, because of the limited lifetime of TPrA radical cations TPrA+•. In combination with the theoretical simulation, the ring-shaped ECL image is resolved to originate from the superposition effect of the mass diffusion fields at both microwell wall and bottom surfaces.
Collapse
|
127
|
Zhang S, Liu Y. Recent Progress of Novel Electrochemiluminescence Nanoprobes and Their Analytical Applications. Front Chem 2021; 8:626243. [PMID: 33634074 PMCID: PMC7900533 DOI: 10.3389/fchem.2020.626243] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Accepted: 12/21/2020] [Indexed: 11/13/2022] Open
Abstract
High-performance nanomaterials have been seen as a new generation of electrochemiluminescence (ECL) probes or emitters for their finely tunable structure and concomitant remarkable properties, guaranteeing the prospective applications in the analysis and diagnosis devices with superior performances. The structure-activity relationships of ECL nanoprobes in nanoscale are presenting milestone in understanding of the ECL microscopic behaviors and mechanisms, and guide the exploitation of novel ECL probes. In this mini-review, we summarized the recent development of novel ECL probes based on the nanomaterials. The mechanism and relationships between their structure as well as the active sites and functionality were revealed. In addition, the design and regulation of the ECL nanoprobes were emphasized for the biosensing and imaging application. Finally, the potential prospect of the ECL nanoprobes, design, and their applications were discussed.
Collapse
|
128
|
Kerr E, Alexander R, Francis PS, Guijt RM, Barbante GJ, Doeven EH. A Comparison of Commercially Available Screen-Printed Electrodes for Electrogenerated Chemiluminescence Applications. Front Chem 2021; 8:628483. [PMID: 33585404 PMCID: PMC7875866 DOI: 10.3389/fchem.2020.628483] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Accepted: 12/28/2020] [Indexed: 12/20/2022] Open
Abstract
We examined a series of commercially available screen-printed electrodes (SPEs) for their suitability for electrochemical and electrogenerated chemiluminescence (ECL) detection systems. Using cyclic voltammetry with both a homogeneous solution-based and a heterogeneous bead-based ECL assay format, the most intense ECL signals were observed from unmodified carbon-based SPEs. Three commercially available varieties were tested, with Zensor outperforming DropSens and Kanichi in terms of sensitivity. The incorporation of nanomaterials in the electrode did not significantly enhance the ECL intensity under the conditions used in this evaluation (such as gold nanoparticles 19%, carbon nanotubes 45%, carbon nanofibers 21%, graphene 48%, and ordered mesoporous carbon 21% compared to the ECL intensity of unmodified Zensor carbon electrode). Platinum and gold SPEs exhibited poor relative ECL intensities (16% and 10%) when compared to carbonaceous materials, due to their high rates of surface oxide formation and inefficient oxidation of tri-n-propylamine (TPrA). However, the ECL signal at platinum electrodes can be increased ∼3-fold with the addition of a surfactant, which enhanced TPrA oxidation due to increasing the hydrophobicity of the electrode surface. Our results also demonstrate that each SPE should only be used once, as we observed a significant change in ECL intensity over repeated CV scans and SPEs cannot be mechanically polished to refresh the electrode surface.
Collapse
|
129
|
Wang C, Han Q, Liu P, Zhang G, Song L, Zou X, Fu Y. A Superstable Luminescent Lanthanide Metal Organic Gel Utilized in an Electrochemiluminescence Sensor for Epinephrine Detection with a Narrow Potential Sweep Range. ACS Sens 2021; 6:252-258. [PMID: 33395257 DOI: 10.1021/acssensors.0c02272] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Metal organic gels (MOGs) as a new type of porous soft-hybrid supramolecular material have attracted widespread interest in various aspects due to their unique optical properties. In this work, we report a novel electrochemiluminescence (ECL) emission (679 nm) lanthanide MOG, which has been synthesized by a simple and rapid method at room temperature. This MOG (Tb-Ru-MOG) consists of a central metal ion, terbium (III), and two different ligands, tris(4,4'-dicarboxylicacid-2,2'-bipyridyl) ruthenium (II) dichloride (Ru(dcbpy)32+) and 4'-(4-carboxyphenyl)-2,2':6',2″-terpyridine (Hcptpy). Compared with the classic system of tris(2,2'-bipyridyl) ruthenium (II) dichloride (Ru(bpy)32+)/S2O82-, Tb-Ru-MOG/S2O82- owns a narrower potential sweep range (0.00 to -0.85 V) and a more stable and stronger ECL signal. Interestingly, the ECL intensity only decreased 2.0 and 0.1% after continuous scanning for 8000 s and storing at room temperature for 3 months. The possible ECL mechanism has been discussed in detail, which is mainly attributed to the internal synergies (antenna effect and energy transfer) and external co-reactant. Inspired by the unique luminescence characteristics of Tb-Ru-MOG, the application in electroanalytical chemistry was identified by the ECL on-off response for epinephrine with a linear range from 1.0 × 10-10 to 1.0 × 10-3 mol·L-1 and a detection limit of 5.2 × 10-11 mol·L-1. The results suggest that the as-proposed Tb-Ru-MOG will provide a robust pathway for new ECL luminophores in analysis.
Collapse
|
130
|
Ma C, Wu S, Zhou Y, Wei HF, Zhang J, Chen Z, Zhu JJ, Lin Y, Zhu W. Bio-Coreactant-Enhanced Electrochemiluminescence Microscopy of Intracellular Structure and Transport. Angew Chem Int Ed Engl 2021; 60:4907-4914. [PMID: 33188721 DOI: 10.1002/anie.202012171] [Citation(s) in RCA: 67] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 10/24/2020] [Indexed: 12/14/2022]
Abstract
A bio-coreactant-enhanced electrochemiluminescence (ECL) microscopy realizes the ECL imaging of intracellular structure and dynamic transport. This microscopy uses Ru(bpy)3 2+ as the electrochemical molecular antenna connecting extracellular and intracellular environments, and uses intracellular biomolecules as the coreactants of ECL reactions via a "catalytic route". Accordingly, intracellular structures are identified without using multiple labels, and autophagy involving DNA oxidative damage is detected using nuclear ECL signals. A time-resolved image sequence discloses the universal edge effect of cellular electroporation due to the influence of the geometric properties of cell membranes on the induced transmembrane voltage. The dynamic transport of Ru(bpy)3 3+ in the different cellular compartments unveils the heterogeneous intracellular diffusivity correlating with the actin cytoskeleton. In addition to single-cell studies, the bio-coreactant-enhanced ECL microscopy is used to image a slice of a mouse liver and a colony of Shewanella oneidensis MR-1.
Collapse
|
131
|
Das S, Ngashangva L, Goswami P. Carbon Dots: An Emerging Smart Material for Analytical Applications. MICROMACHINES 2021; 12:84. [PMID: 33467583 PMCID: PMC7829846 DOI: 10.3390/mi12010084] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 01/09/2021] [Accepted: 01/12/2021] [Indexed: 12/16/2022]
Abstract
Carbon dots (CDs) are optically active carbon-based nanomaterials. These nanomaterials can change their light emission properties in response to various external stimuli such as pH, temperature, pressure, and light. The CD's remarkable stimuli-responsive smart material properties have recently stimulated massive research interest for their exploitation to develop various sensor platforms. Herein, an effort has been made to review the major advances made on CDs, focusing mainly on its smart material attributes and linked applications. Since the CD's material properties are largely linked to their synthesis approaches, various synthesis methods, including surface passivation and functionalization of CDs and the mechanisms reported so far in their photophysical properties, are also delineated in this review. Finally, the challenges of using CDs and the scope for their further improvement as an optical signal transducer to expand their application horizon for developing analytical platforms have been discussed.
Collapse
|
132
|
He Y, Liu Y, Cheng L, Yang Y, Qiu B, Guo L, Wang Y, Lin Z, Hong G. Highly Reproducible and Sensitive Electrochemiluminescence Biosensors for HPV Detection Based on Bovine Serum Albumin Carrier Platforms and Hyperbranched Rolling Circle Amplification. ACS APPLIED MATERIALS & INTERFACES 2021; 13:298-305. [PMID: 33382593 DOI: 10.1021/acsami.0c20742] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Most DNA-based electrochemiluminescence (ECL) biosensors are established through the self-assembly of thiolated single-stranded DNA (ssDNA) probes on the Au electrode surface. Because of this random assembly process, a significant discrepancy exists in the distribution of a modified DNA film on different electrodes, which greatly affects the reproducibility of a biosensor. In this study, a porous bovine serum albumin (BSA) layer was first modified on the electrode surface, which can improve the position distribution and spatial orientation of the self-assembly ssDNA probe. It was then coupled with hyperbranched rolling circle amplification to develop the high-reproducibility-and-sensitivity ECL biosensor for human papillomavirus 16 E6 and E7 oncogene detection. In the presence of the target DNA, the surface of the electrode accumulates abundant amplified products through reaction, which contain double-stranded DNA (dsDNA) fragments of different lengths, followed by plentiful dichlorotris (1,10-phenanthroline) ruthenium(II) hydrate (Ru(phen)32+, acting as an ECL indicator) insertion into grooves of dsDNA fragments, and a strong signal can be detected. There is a linear relationship between the signal and the target concentration range from 10 fM to 15 pM, and the detection limit is 7.6 fM (S/N = 3). After the BSA modification step, the relative standard deviation was reduced from 9.20 to 3.96%, thereby achieving good reproducibility. The proposed ECL strategy provides a new method for constructing high-reproducibility-and-sensitivity ECL biosensors.
Collapse
|
133
|
Li Y, Wang Z, Mao H, Wang J, Gong W, Chen C, Shi L, Sun J, Huo J. [Comparative study of the detection of serum folate with improved microbial assay and electrochemiluminescence method]. WEI SHENG YAN JIU = JOURNAL OF HYGIENE RESEARCH 2021; 50:111-115. [PMID: 33517971 DOI: 10.19813/j.cnki.weishengyanjiu.2021.01.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
OBJECTIVE To compare the result of serum folate determined by improved microbial assay and electrochemiluminescence method, and to look for the relationship between them, so as to provide basis for the assessment of nutrition status of folate in population. METHODS A total of 258 serum samples were examined by improved microbial assay and electrochemiluminescence method. The correlation and consistence of the two method were analyzed. RESULTS The result showed that the correlation coefficient of the two method was 0. 885, which indicated that the result of two method were highly correlated. Results of Bland-Altman method showed that 94. 5% of the values were within the consistency limit, and the Kappa value of Kappa test was 0. 665. The result of consistency analysis showed that there were some differences between the two methods, and the result of serum folate tested by improved microbial assay were higher than that of electrochemiluminescence method in general. CONCLUSION The result of serum folate tested by electrochemiluminescence were highly correlated with the improved microbial assay, yet there are some differences in the consistency result between the two methods. Evaluating the nutrition status of folate by electrochemiluminescence may lead to a higher number of folate deficiency.
Collapse
|
134
|
Kim JH, Kim J. Post-Synthesis Modification of Photoluminescent and Electrochemiluminescent Au Nanoclusters with Dopamine. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 11:E46. [PMID: 33375457 PMCID: PMC7824466 DOI: 10.3390/nano11010046] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/04/2020] [Revised: 12/20/2020] [Accepted: 12/24/2020] [Indexed: 12/24/2022]
Abstract
Here, we report a post-synthesis functionalization of the shell of Au nanoclusters (NCs) synthesized using glutathione as a thiolate ligand. The as-synthesized Au NCs are subjected to the post-synthesis functionalization via amidic coupling of dopamine on the cluster shell to tailor photoluminescence (PL) and electrochemiluminescence (ECL) features of the Au NCs. Because the NCs' PL at ca. 610 nm is primarily ascribed to the Au(I)-thiolate (SG) motifs on the cluster shell of the NCs, the post-synthesis functionalization of the cluster shell enhanced the PL intensity of the Au NCs via rigidification of the cluster shell. In contrast to the PL enhancement, the post-synthesis modification of the cluster shell does not enhance the near-infrared (NIR) ECL of the NCs because the NIR ECL at ca. 800 nm is ascribed to the Au(0)-SG motifs in the metallic core of the NCs.
Collapse
|
135
|
Wang L, Liu P, Liu Z, Zhao K, Ye S, Liang G, Zhu JJ. Simple Tripedal DNA Walker Prepared by Target-Triggered Catalytic Hairpin Assembly for Ultrasensitive Electrochemiluminescence Detection of MicroRNA. ACS Sens 2020; 5:3584-3590. [PMID: 33170660 DOI: 10.1021/acssensors.0c01864] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
In contrast to common DNA walkers, multipedal DNA walkers exhibit larger walking area and faster walking kinetics and provide increased amplification efficiency. Consequently, they have received a considerable amount of attention in biosensing. However, most of them are synthesized by immobilizing multiple DNA walking strands on the surface of Au nanoparticles, which is tedious and time-consuming. Simple preparation of multipedal DNA walkers remains a challenge. Herein, we adopted a simple enzyme-free target-triggered catalytic hairpin assembly (CHA) circuit to synthesize a tripedal DNA walker. By walking on a DNA track-functionalized electrode, a sensitive electrochemiluminescence DNA nanomachine biosensor was constructed for sensing miRNA-21. The DNA walker was powered by toehold-mediated strand displacement; the whole process did not need the assistance of enzymes, thus avoiding tedious procedures and enzyme degradation under unfavorable environmental conditions. Specifically, a superior detection limit of 4 aM and a broad linear range of 10 aM to 1 pM were achieved. This CHA-tripedal DNA walker biosensor was then applied for the detection of miRNA-21 in human serum and showed high selectivity and excellent reproducibility, demonstrating its practical application in bioanalysis. In particular, the Y-shaped tripedal DNA walker comes from the DNA circuit, which makes the approach ideally suited for biosensing of small nucleic acid targets.
Collapse
|
136
|
Yang L, Hendsbee AD, Xue Q, He S, De-Jager CR, Xie G, Welch GC, Ding Z. Atomic Precision Graphene Model Compound for Bright Electrochemiluminescence and Organic Light-Emitting Diodes. ACS APPLIED MATERIALS & INTERFACES 2020; 12:51736-51743. [PMID: 33155464 DOI: 10.1021/acsami.0c16238] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
An N-annulated perylene diimide dimer, tPDI2N-hex, a graphene model compound with atomic precision, was investigated for luminescence applications. Electrochemiluminescence (ECL) of tPDI2N-hex was studied with tri-n-propylamine (TPrA) as a reducing coreactant. ECL-voltage curves along with spooling ECL spectra provided details of light generation mechanisms. The relative ECL quantum efficiency of the Ru(bpy)3(PF6)2/TPrA system was calculated to be 64%, which is superior to that of many other organic molecules because of the desired excited state in the absence of surface states. An organic light-emitting diode (OLED) fabricated with tPDI2N-hex displayed bright orange-red emission with a low color temperature, which is very desirable. It is plausible that the sterically constrained and thus orthogonal aromatic moieties in the tPDI2N-hex structure, with atomic precision graphene layer characteristics, lead to the excellent luminescence performances. The ECL and OLED studies of tPDI2N-hex showcase great application potentials of tPDI2N-hex in both solution-based ECL probes and solid-state light devices.
Collapse
|
137
|
Newman B, Chen L, Henderson LC, Doeven EH, Francis PS, Hayne DJ. Water-Soluble Iridium(III) Complexes Containing Tetraethylene-Glycol-Derivatized Bipyridine Ligands for Electrogenerated Chemiluminescence Detection. Front Chem 2020; 8:583631. [PMID: 33195075 PMCID: PMC7593781 DOI: 10.3389/fchem.2020.583631] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Accepted: 09/03/2020] [Indexed: 11/13/2022] Open
Abstract
Four cationic heteroleptic iridium(III) complexes containing a 2,2′-bipyridine (bpy) ligand with one or two tetraethylene glycol (TEG) groups attached in the 4 or 4,4′ positions were synthesized to create new water-soluble electrogenerated chemiluminescence (ECL) luminophores bearing a convenient point of attachment for the development of ECL-labels. The novel TEG-derivatized bipyridines were incorporated into [Ir(C∧N)2(R-bpy-R′)]Cl complexes, where C∧N = 2-phenylpyridine anion (ppy) or 2-phenylbenzo[d]thiazole anion (bt), through reaction with commercially available ([Ir(C∧N)2(μ-Cl)]2 dimers. The novel [Ir(C∧N)2(Me-bpy-TEG)]Cl and [Ir(C∧N)2(TEG-bpy-TEG)]Cl complexes in aqueous solution largely retained the redox potentials and emission spectra of the parent [Ir(C∧N)2(Me-bpy-Me)]PF6 (where Me-bpy-Me = 4,4′methyl-2,2′-bipyridine) luminophores in acetonitrile, and exhibited ECL intensities similar to those of [Ru(bpy)3]2+ and the analogous [Ir(C∧N)2(pt-TEG]Cl complexes (where pt-TEG = 1-(TEG)-4-(2-pyridyl)-1,2,3-triazole). These complexes can be readily adapted for bioconjugation and considering the spectral distributions of [Ir(ppy)2(Me-bpy-TEG)]+ and [Ir(ppy)2(pt-TEG)]+, show a viable strategy to create ECL-labels with different emission colors from the same commercial [Ir(ppy)2(μ-Cl)]2 precursor.
Collapse
|
138
|
Wyant T, Yang L, Rosario M. Comparison of the ELISA and ECL Assay for Vedolizumab Anti-drug Antibodies: Assessing the Impact on Pharmacokinetics and Safety Outcomes of the Phase 3 GEMINI Trials. AAPS JOURNAL 2020; 23:3. [PMID: 33200296 PMCID: PMC7669784 DOI: 10.1208/s12248-020-00518-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Accepted: 10/06/2020] [Indexed: 01/12/2023]
Abstract
Vedolizumab immunogenicity has been assessed using an enzyme-linked immunosorbent assay (ELISA) with a ~ 0.5 μg/mL drug interference, which may underestimate on-drug immunogenicity. We aimed to compare immunogenicity results between ELISA and the new drug-tolerant electrochemiluminescence (ECL) assay (and the two versions of neutralizing assays, drug-sensitive versus drug-tolerant). The ECL assay drug tolerance is ~ 100 times higher than that of the ELISA (≥ 50 μg/mL vs. 0.5 μg/mL with a 500 ng/mL positive control), and assay sensitivity is < 5 ng/mL for both assays. Vedolizumab immunogenicity was assessed in 2000 GEMINI 1 and 2 patients originally tested by ELISA and retested by ECL assay. Anti-drug antibody (ADA) impact on infusion-related reactions and pharmacokinetics (PK) was examined using descriptive statistics and population PK analyses. By ECL assay, 6% (86/1427) of patients treated with vedolizumab as induction and maintenance therapy tested ADA-positive. Of these, 20 patients were persistently positive and 56 had neutralizing antibodies. By ELISA, 4% (56/1434) of these patients were ADA-positive, 9 were persistently positive, and 33 had neutralizing antibodies. Among 61 patients with infusion-related reactions, 6 (10%) were ADA-positive (2 persistently positive) by ECL assay. By ELISA, 3 (5%) patients were both ADA-positive and persistently positive. Most results (96%) were similar with both assays. In the updated population PK model, ADA-positive status was estimated to increase vedolizumab linear clearance by a factor of 1.10 (95% credible interval 1.03-1.17), which is consistent with previous reports. The impact of ADA on safety and PK modeling remained generally consistent using either ELISA or ECL assay. ClinicalTrials.gov: NCT00783718 and NCT00783692.
Collapse
|
139
|
Liu Q, Bai W, Guo Z, Zheng X. Enhanced electrochemiluminescence of Ru(bpy) 3 2+ -doped silica nanoparticles by chitosan/Nafion shell@carbon nanotube core-modified electrode. LUMINESCENCE 2020; 36:642-650. [PMID: 33171543 DOI: 10.1002/bio.3979] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Revised: 10/26/2020] [Accepted: 11/04/2020] [Indexed: 11/11/2022]
Abstract
Although Ru(bpy)3 2+ -doped silica nanoparticles have been widely explored as the labelling tags for electrochemiluminescence (ECL) sensing different targets, the poor electrical conductive properties of the silica nano-matrix greatly limit their ECL sensitivity. Therefore, a novel scheme to overcome this drawback on Ru(bpy)3 2+ -doped silica nanoparticles ECL is desirable. Here, a new scheme for this purpose was developed based on electrochemically depositing a nanoscale chitosan hydrogel layer on the carbon nanotube (CNT) surface to form chitosan hydrogel shell@CNT core nanocomposites. In this case, the nanoscale chitosan hydrogel layer only formed on the CNT surface due to the superior electrocatalytic effect of CNT on H+ reduction compared with the basic glass carbon electrode. Due to both the superhydrophilic properties and polyelectrolyte features of nanoscale chitosan hydrogel on the CNT surface, chemical affinity as well as the electric conductivity between Ru(bpy)3 2+ -doped silica nanoparticles and CNT were obviously enhanced, and then the ECL effectivity of Ru(bpy)3 2+ inside silica nanoparticles was improved. Furthermore, based on the discriminative interaction of these Ru(bpy)3 2+ -doped silica nanoparticles towards both the ssDNA probes and the ssDNA probe/miRNA complex, as well as the specific adsorption effect of these nanoparticles on the nanoscale chitosan shell@Nafion/CNT core-modified glass carbon electrode, a highly sensitive ECL method for miRNA determination was developed and successfully used to detect miRNA in human serum samples.
Collapse
|
140
|
Hong D, Jo EJ, Kim K, Song MB, Kim MG. Ru(bpy) 32+ -Loaded Mesoporous Silica Nanoparticles as Electrochemiluminescent Probes of a Lateral Flow Immunosensor for Highly Sensitive and Quantitative Detection of Troponin I. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e2004535. [PMID: 33048467 DOI: 10.1002/smll.202004535] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Indexed: 05/14/2023]
Abstract
The lateral flow immunosensor (LFI) is a widely used diagnostic tool for biomarker detection; however, its sensitivity is often insufficient for analyzing targets at low concentrations. Here, an electrochemiluminescent LFI (ECL-LFI) is developed for highly sensitive detection of troponin I (TnI) using Ru(bpy)32+ -loaded mesoporous silica nanoparticles (RMSNs). A large amount of Ru(bpy)32+ is successfully loaded into the mesoporous silica nanoparticles with excellent loading capacity and shows strong ECL signals in reaction to tripropylamine. Antibody-immobilized RMSNs are applied to detect TnI by fluorescence and ECL analysis after a sandwich immunoassay on the ECL-LFI strip. The ECL-LFI enables the highly sensitive detection of TnI-spiked human serum within 20 min at femtomolar levels (≈0.81 pg mL-1 ) and with a wide dynamic range (0.001-100 ng mL-1 ), significantly outperforming conventional fluorescence detection (>3 orders of magnitude). Furthermore, TnI concentrations in 35 clinical serum samples across a low range (0.01-48.31 ng mL-1 ) are successfully quantified with an excellent linear correlation (R2 = 0.9915) using a clinical immunoassay analyzer. These results demonstrate the efficacy of this system as a high-performance sensing strategy capable of capitalizing on future point-of-care testing markets for biomolecule detection.
Collapse
|
141
|
Zhang Y, Zhao Y, Han Z, Zhang R, Du P, Wu Y, Lu X. Switching the Photoluminescence and Electrochemiluminescence of Liposoluble Porphyrin in Aqueous Phase by Molecular Regulation. Angew Chem Int Ed Engl 2020; 59:23261-23267. [PMID: 32888252 DOI: 10.1002/anie.202010216] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2020] [Revised: 08/25/2020] [Indexed: 01/10/2023]
Abstract
By a facile peripheral decoration of 5-(4-aminophenyl)-10,15,20-triphenylporphyrin (ATPP) with inherent aggregation-induced emission (AIE) active tetraphenylethene (TPE), a versatile AIEgenic porphyrin derivative (ATPP-TPE) was obtained, which greatly abolishes the detrimental π-π stacking and thus surmounts the notorious aggregation-caused quenching (ACQ) effect of ATPP in aqueous phase. The photoluminescence of ATPP-TPE is 4.5-fold stronger than ATPP at aggregation state. Moreover, an unequivocal aggregation induced electrochemiluminescence (AIECL) of ATPP-TPE was found to be seriously dependent on its aggregation property in aqueous solution with efficiency of 34 %, which is 6 times higher than pure ATPP. The versatility of this molecular structure modulation strategy along with the ACQ-to-AIE transformation in this work provides direction to guide for applying liposoluble porphyrins in aqueous phase by designs of synthetic porphyrin AIEgens.
Collapse
|
142
|
Mauriz E. Recent Progress in Plasmonic Biosensing Schemes for Virus Detection. SENSORS 2020; 20:s20174745. [PMID: 32842601 PMCID: PMC7506724 DOI: 10.3390/s20174745] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 08/20/2020] [Accepted: 08/20/2020] [Indexed: 12/16/2022]
Abstract
The global burden of coronavirus disease 2019 (COVID-19) to public health and global economy has stressed the need for rapid and simple diagnostic methods. From this perspective, plasmonic-based biosensing can manage the threat of infectious diseases by providing timely virus monitoring. In recent years, many plasmonics’ platforms have embraced the challenge of offering on-site strategies to complement traditional diagnostic methods relying on the polymerase chain reaction (PCR) and enzyme-linked immunosorbent assays (ELISA). This review compiled recent progress on the development of novel plasmonic sensing schemes for the effective control of virus-related diseases. A special focus was set on the utilization of plasmonic nanostructures in combination with other detection formats involving colorimetric, fluorescence, luminescence, or Raman scattering enhancement. The quantification of different viruses (e.g., hepatitis virus, influenza virus, norovirus, dengue virus, Ebola virus, Zika virus) with particular attention to Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) was reviewed from the perspective of the biomarker and the biological receptor immobilized on the sensor chip. Technological limitations including selectivity, stability, and monitoring in biological matrices were also reviewed for different plasmonic-sensing approaches.
Collapse
|
143
|
Yang L, Koo D, Wu J, Wong JM, Day T, Zhang R, Kolongoda H, Liu K, Wang J, Ding Z, Pagenkopf BL. Benzosiloles with Crystallization-Induced Emission Enhancement of Electrochemiluminescence: Synthesis, Electrochemistry, and Crystallography. Chemistry 2020; 26:11715-11721. [PMID: 32484982 DOI: 10.1002/chem.202002647] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Indexed: 01/19/2023]
Abstract
Crystallization-induced emission enhancement (CIEE) was demonstrated for the first time for electrochemilunimescence (ECL) with two new benzosiloles. Compared with their solution, the films of the two benzosiloles gave CIEE of 24 and 16 times. The mechanism of the CIEE-ECL was examined by spooling ECL spectroscopy, X-ray crystal structure analysis, photoluminescence, and DFT calculations. This CIEE-ECL system is a complement to the well-established aggregation-induced emission enhancement (AIEE) systems. Unique intermolecular interactions are noted in the crystalline chromophore. The first heterogeneous ECL system is established for organic compounds with highly hydrophobic properties.
Collapse
|
144
|
Huang X, Jia J, Lin Y, Qiu B, Lin Z, Chen H. A Highly Sensitive Electrochemiluminescence Biosensor for Pyrophosphatase Detection Based on Click Chemistry-Triggered Hybridization Chain Reaction in Homogeneous Solution. ACS APPLIED MATERIALS & INTERFACES 2020; 12:34716-34722. [PMID: 32643920 DOI: 10.1021/acsami.0c10542] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The abnormal expression of pyrophosphatase (PPase) is closely related to many diseases and malignant tumors, so the detection for PPase is of great significance in clinical diagnosis, disease monitoring, and other biomedical aspects. In this study, a sensitive and specific electrochemiluminescence (ECL) biosensor combined highly specific Cu+-catalyzed azide-alkyne cycloaddition (CuAAC) with high efficiency of hybridization chain reaction (HCR) for the purpose of detecting pyrophosphatase has been designed. Highly efficient hybridization chain reaction amplification processed in homogeneous solution and the amplification products were connected to the electrode surface in one step, which solved the problem of low DNA amplification efficiency on the electrode surface because of the steric hindrance. Ru(phen)32+ was embedded into the dsDNA and functioned as ECL probes; the enhanced ECL intensity of the system had a linear relationship with the logarithm of PPase concentration in the range of 0.025-50 mU with a detection limit of 8 μU. The method was proved to be of good specificity, repeatability, and stability that could be used for screening and quantitatively determining pyrophosphatase inhibitor sodium fluoride. The practicability of this method in clinical application has been proved through the detection of serum from the clinical arthritis patients. Moreover, the method can be used to monitor PPase activity of arthritis patients before and after administration to provide reference for the effect of drug treatment.
Collapse
|
145
|
Rivera EC, Summerscales RL, Tadi Uppala PP, Kwon HJ. Electrochemiluminescence Mechanisms Investigated with Smartphone-Based Sensor Data Modeling, Parameter Estimation and Sensitivity Analysis. ChemistryOpen 2020; 9:854-863. [PMID: 32832344 PMCID: PMC7435146 DOI: 10.1002/open.202000165] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 07/07/2020] [Indexed: 12/13/2022] Open
Abstract
The present study introduces a unified framework combining a mechanistic model with a genetic algorithm (GA) for the parameter estimation of electrochemiluminescence (ECL) kinetics of the Ru(bpy)32+/TPrA system occurring in a smartphone-based sensor. The framework allows a straightforward solution for simultaneous estimation of multiple parameters which can be, otherwise, time-consuming and lead to non-convergence. Model parameters are estimated by achieving a high correlation between the model prediction and the measured ECL intensity from the ECL sensor. The developed model is used to perform a sensitivity analysis (SA), which provides quantitative effects of the model parameters on the concentrations of chemical species involved in the system. The results demonstrate that the GA-based parameter estimation and the SA approaches are effective in analyzing the kinetics of the ECL mechanism. Therefore, these approaches can be incorporated as analysis tools in the ECL kinetics study with practical application in the calibration of mechanistic models for any required sensing condition.
Collapse
|
146
|
Kwon DK, Myoung JM. Wearable and Semitransparent Pressure-Sensitive Light-Emitting Sensor Based on Electrochemiluminescence. ACS NANO 2020; 14:8716-8723. [PMID: 32644780 DOI: 10.1021/acsnano.0c03186] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Tactile sensors are being researched as a key technology for developing an electronic skin and a wearable display, which have recently been attracting much attention. However, to develop a next-generation wearable tactile sensor, it is necessary to implement an interactive display that responds immediately to external stimuli. Herein, a wearable and semitransparent pressure-sensitive light-emitting sensor (PLS) based on electrochemiluminescence (ECL) is successfully implemented with visual alarm functions to prevent damage to the human body from external stimuli. The PLS is fabricated with a very simple structure using the ECL gel as the light-emitting layer and a carbon nanotube embedded polydimethylsiloxane as the electrode. The ECL light-emitting layer using a redox reaction is advantageous for the fabrication of next-generation wearable devices due to the advantages of a simple structure and the use of electrodes without work function limitation. The PLS can display various external stimuli immediately and operate at a high luminance, making it safe to use as a wearable sensor. Therefore, the PLS using ECL can be a simple and meaningful solution for next-generation wearable tactile sensors.
Collapse
|
147
|
Lv M, Wang F, Wang X, Zhang C. Diagnostic value of human epididymis protein 4 in malignant pleural effusion in lung cancer. Cancer Biomark 2020; 26:523-528. [PMID: 31658049 DOI: 10.3233/cbm-190840] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
OBJECTIVE This study aimed to assess the diagnostic value of human epididymis protein 4 (HE4) in the pleural effusion of lung cancer patients. METHODS HE4 protein in the pleural effusion of 60 lung cancer patients was measured by electrochemiluminescence, in parallel with those from 56 patients with benign lung disease, and the association with malignant pleural effusion was evaluated. RESULTS The level of HE4 in samples from lung cancer patients was significantly higher than the level for those with benign lung lesions (P= 0.001) and patients with lung adenocarcinoma showed significantly higher levels of HE4 than those with squamous cell carcinoma and small cell carcinoma (P= 0.002 and P= 0.034, respectively). Using an optimal threshold of 652.2 pmol/L, the HE4 level distinguished malignant lung cancer from benign lesions with a sensitivity of 78.3% and a specificity of 75.0%. Moreover, the HE4 level differentiated adenocarcinoma from benign lesions with a sensitivity of 75.9% and a specificity of 85.7% when a threshold of 744.05 pmol/L was used. However, there was no significant difference in the 2 year survival rates of lung cancer patients with high and low HE4 concentrations in pleural fluid (P= 0.882). In addition, there was no significant difference in HE4 levels between tuberculous and inflammatory pleural effusions (P= 0.309). CONCLUSION HE4 in the pleural fluid of lung cancer patients can be valuable in the diagnosis of malignant pleural effusion; however, it does not correlate with the prognosis of patients.
Collapse
|
148
|
Ino K, Yaegaki R, Hiramoto K, Nashimoto Y, Shiku H. Closed Bipolar Electrode Array for On-Chip Analysis of Cellular Respiration by Cell Aggregates. ACS Sens 2020; 5:740-745. [PMID: 31997640 DOI: 10.1021/acssensors.9b02061] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Cell aggregates have attracted much attention owing to their potential applications in tissue engineering and drug screening. To evaluate cellular respiration of individual cell aggregates in these applications, noninvasive and on-chip high-throughput analytical tools are necessary. Electrochemical methods for detecting oxygen concentrations are useful because of their noninvasiveness. However, these conventional methods may be unsuitable for high-throughput detection because it is difficult to prepare many electrodes on a small chip owing to the limitation of area for connecting electrodes. Alternatively, a bipolar electrode (BPE) system offers clear advantages. In this system, electrochemical reactions are induced at both ends of a BPE without complex wiring. In this study, we present a BPE array for detecting the respiratory activity of cell aggregates. Oxygen concentrations near cell aggregates at cathodic poles of BPEs were converted to electrochemiluminescence (ECL) signals of [Ru(bpy)3]2+/tripropylamine at anodic poles of BPEs. To separate ECL chemicals from cell aggregates, we fabricated a closed BPE device containing analytical and reporter chambers. As a proof of concept, 32 BPEs were controlled wirelessly using a pair of driving electrodes, and the respiratory activities of individual MCF-7 cell aggregates as a cancer model were successfully detected by monitoring ECL signals. Compared with conventional electrode arrays for cell analysis, the wiring of the current device was simple because the multiple BPEs functioned with only a single power supply. To the best of our knowledge, this is the first study of on-chip analysis of cellular activity using a BPE system.
Collapse
|
149
|
Fan Z, Lin Z, Wang Z, Wang J, Xie M, Zhao J, Zhang K, Huang W. Dual-Wavelength Electrochemiluminescence Ratiometric Biosensor for NF-κB p50 Detection with Dimethylthiodiaminoterephthalate Fluorophore and Self-Assembled DNA Tetrahedron Nanostructures Probe. ACS APPLIED MATERIALS & INTERFACES 2020; 12:11409-11418. [PMID: 32067445 DOI: 10.1021/acsami.0c01243] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
In this work, we fabricated a dual-wavelength electrochemiluminescence ratiometric biosensor based on electrochemiluminescent resonance energy transfer (ECL-RET). In this biosensor, Au nanoparticle-loaded graphitic phase carbon nitride (Au-g-C3N4) as a donor and Au-modified dimethylthiodiaminoterephthalate (TAT) analogue (Au@TAT) as an acceptor were investigated for the first time. Besides, tetrahedron DNA probe was immobilized onto Au-g-C3N4 to improve the binding efficiency of the transcription factor and ECL ratiometric changes on the basis of the ratio of ECL intensities at 595 and 460 nm, which were obtained through the formation of a sandwich structure of DNA probe-antigen-antibody. Our biosensor achieved the assay of NF-κB p50 with a detection limit of 5.8 pM as well as high stability and specificity.
Collapse
|
150
|
Guo W, Ding H, Zhou P, Wang Y, Su B. Electrochemiluminescence Waveguide in Single Crystalline Molecular Wires. Angew Chem Int Ed Engl 2020; 59:6745-6749. [PMID: 31944544 DOI: 10.1002/anie.201915984] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Revised: 01/05/2020] [Indexed: 12/16/2022]
Abstract
Here we report the first observation of active waveguide of electrochemiluminescence (ECL) in single crystalline molecular wires self-assembled from cyclometalated iridium(III) complexes, namely tris(1-phenylisoquinoline-C2 , N) (Ir(piq)3 ). Under dark conditions, the molecular wires deposited on the electrode surface can act as both ECL emitters and active waveguides. As revealed by ECL microscopy, they exhibit the typical characteristics of optical waveguides, transmitting ECL and generating much brighter ECL emission at their terminals. Moreover, self-generated ECL can be confined inside the molecular wire and propagates along the longitudinal direction as far as ≈100 μm to the terminal out of touch with the electrode. Therefore, this one-dimensional crystalline molecular wire-based waveguide offers the opportunity to switch the electrochemically generated ECL to remote light emission in non-conductive regions and is promising for contactless electrochemical analysis and study of (bio)chemical systems.
Collapse
|