151
|
Seneca N, Gulyás B, Varrone A, Schou M, Airaksinen A, Tauscher J, Vandenhende F, Kielbasa W, Farde L, Innis RB, Halldin C. Atomoxetine occupies the norepinephrine transporter in a dose-dependent fashion: a PET study in nonhuman primate brain using (S,S)-[18F]FMeNER-D2. Psychopharmacology (Berl) 2006; 188:119-27. [PMID: 16896954 DOI: 10.1007/s00213-006-0483-3] [Citation(s) in RCA: 65] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2006] [Accepted: 06/16/2006] [Indexed: 12/23/2022]
Abstract
RATIONALE Atomoxetine is a potent and selective norepinephrine transporter (NET) reuptake inhibitor acting as a nonstimulant for the treatment of attention-deficit/hyperactivity disorder (ADHD). Previous positron emission tomography (PET) studies had failed to demonstrate the feasibility of measuring a dose-dependent and saturable NET occupancy in human brain using [11C]MeNER. OBJECTIVES To determine if atomoxetine occupies NET in a dose-dependent fashion using (S,S)-[18F]FMeNER-D2 in nonhuman primate brain. METHODS A total of eight PET measurements were performed in two cynomolgus monkeys. Each monkey was examined four times with PET: under baseline conditions and after steady-state infusion with 0.03, 0.06, or 0.12 mg/kg/h of atomoxetine. A prolonged intravenous (i.v.) infusion design was developed rather than an i.v. bolus to better mimic an oral absorption profile and to reach plasma steady state. RESULTS During baseline conditions, (S,S)-[18F]FMeNER-D2 uptake was highest in the locus coeruleus, thalamus, mesencephalon, and the cingulate gyrus, whereas the radioactivity in the caudate was low. Peak equilibrium measurements were achieved using (S,S)-[18F]FMeNER-D2 in contrast to the previously reported data for [11C]MeNER. After administration of atomoxetine, a dose-dependent occupancy from 38 to 82% was observed for various brain regions known to contain high densities of NET. CONCLUSIONS This is the first in vivo PET study to successfully demonstrate the ability to measure a dose-dependent change in NET occupancy in brain using (S,S)-[18F]FMeNER-D2. Furthermore, an asymptotic relationship between N-desmethylatomoxetine plasma concentration and NET occupancy was established. In total, these data encourage further PET studies using (S,S)-[18F]FMeNER-D2 in humans.
Collapse
|
152
|
Vander Borght T, Asenbaum S, Bartenstein P, Halldin C, Kapucu O, Van Laere K, Varrone A, Tatsch K. EANM procedure guidelines for brain tumour imaging using labelled amino acid analogues. Eur J Nucl Med Mol Imaging 2006; 33:1374-80. [PMID: 16932934 DOI: 10.1007/s00259-006-0206-3] [Citation(s) in RCA: 92] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
153
|
Salvatore E, Varrone A, Sansone V, Nolano M, Bruni AC, De Rosa A, Santoro L, Pappatà S, Filla A, De Michele G. Characterization of nigrostriatal dysfunction in spinocerebellar ataxia 17. Mov Disord 2006; 21:872-5. [PMID: 16532453 DOI: 10.1002/mds.20827] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Extrapyramidal signs are a main feature of spinocerebellar ataxia 17 (SCA17). However, the extent of dopaminergic dysfunction and its correlation with parkinsonian signs are not fully understood. In order to define this, we investigated five subjects from three different families with a pathological CAG/CAA expansion in the TATA-binding protein gene (SCA17), ranging from asymptomatic carrier to patient with advanced disease, by FP-CIT SPECT. Nigrostriatal dysfunction was present in patients manifesting a fully developed phenotype but not in preclinical and early stages. Dopamine transporter reduction was symmetrical and uniform in caudate and putamen and it correlated with the clinical severity of ataxia.
Collapse
|
154
|
Cuocolo A, Acampa W, Varrone A, Salvatore M. Highlights of the Annual Congress of the European Association of Nuclear Medicine, Istanbul, 2005: the incremental value of nuclear medicine for patient management and care. Eur J Nucl Med Mol Imaging 2006; 33:360-81. [PMID: 16538466 DOI: 10.1007/s00259-006-1986-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The 2005 Annual Congress of the European Association of Nuclear Medicine (EANM) took place in Istanbul on October 15-19, under the chairmanship of Professor Hatice Durak. The programme was of excellent quality and represented a further step towards the achievement of a standardized EANM congress structure. A large industrial exhibition demonstrated the latest technological innovations and developments within the field. The congress was a great success: there were more than 4,000 participants, and 1,670 abstracts were received. Of these, 1,399 were accepted for oral or poster presentations, with a rejection rate of 16.2%. The original investigations presented were related to different areas of nuclear medicine, and addressed particularly advances in instrumentation and data processing, progress in radiochemistry and pharmacy, novel diagnostics and therapeutics, and new insights in well-established areas of clinical application, such as oncology, cardiology, neurology, psychiatry, endocrinology, paediatrics, nephrology, and infection and inflammation. It is noteworthy that a number of studies presented at this congress focussed on the quantitative interpretation of the imaging data and on pragmatic endpoints, such as adverse outcomes, and identified when nuclear medicine procedures achieved clinical effectiveness for patient care and management. These and many other studies presented at the congress demonstrate once more the crucial role that nuclear medicine has to play in contemporary medicine. This highlights lecture is only a brief summary of the large amount of data presented and discussed, which can be found in much greater detail in the congress proceedings book, published as volume 32, supplement 1 of the Eur J Nucl Med Mol Imaging in September 2005.
Collapse
|
155
|
Schou M, Pike VW, Varrone A, Gulyás B, Farde L, Halldin C. Synthesis and PET evaluation of (R)-[S-methyl-11C]thionisoxetine, a candidate radioligand for imaging brain norepinephrine transporters. J Labelled Comp Radiopharm 2006. [DOI: 10.1002/jlcr.1128] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
156
|
Varrone A, Pellecchia MT, Amboni M, Sansone V, Salvatore E, Ghezzi D, Garavaglia B, Brice A, Brunetti A, Bonavita V, De Michele G, Salvatore M, Pappatà S, Barone P. Imaging of dopaminergic dysfunction with [123I]FP-CIT SPECT in early-onset parkin disease. Neurology 2004; 63:2097-103. [PMID: 15596756 DOI: 10.1212/01.wnl.0000145765.19094.94] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
OBJECTIVE To investigate whether the presence of parkin gene mutations is associated with different nigrostriatal impairment than other early-onset parkinsonism. METHODS Eighteen consecutive early-onset Parkinson disease (PD) patients (nine parkin and nine nonparkin patients) and six controls were studied with [123I]FP-CIT SPECT. RESULTS Parkin patients had longer disease duration (15 +/- 9 vs 6 +/- 2 years, p = 0.008) and higher Unified Parkinson's Disease Rating Scale (UPDRS) motor score (35.8 +/- 13.7 vs 22.8 +/- 7.9, p = 0.025) than nonparkin patients. Caudate and putamen DAT density were reduced by 60% and 79% in parkin and by 43% and 70% in nonparkin patients. Multiple regression analysis showed that the UPDRS and the presence of parkin gene mutations, but not the disease duration, were significantly correlated with the striatal DAT density. Parkin patients showed a more symmetric DAT loss in both caudate and putamen as compared with nonparkin patients. CONCLUSIONS Parkin-related disease may be associated with a higher degree of nigrostriatal impairment, independently of the clinical severity of the disease, and a more symmetric involvement as compared with non-parkin early-onset disease.
Collapse
|
157
|
Varrone A, Salvatore E, De Michele G, Barone P, Sansone V, Pellecchia MT, Castaldo I, Coppola G, Brunetti A, Salvatore M, Pappatà S, Filla A. Reduced striatal [123I]FP-CIT binding in SCA2 patients without parkinsonism. Ann Neurol 2004; 55:426-30. [PMID: 14991822 DOI: 10.1002/ana.20054] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Degeneration of substantia nigra has been described in spinocerebellar ataxia type 2 (SCA2). In this study, dopamine transporter (DAT) density with [123 I]FP-CIT SPECT was studied in six SCA2 patients with no parkinsonian signs, six Parkinson's disease (PD) patients, and six controls. Marked striatal DAT loss was found in both SCA2 and PD patients. However, a more severe reduction in the caudate and a higher putamen to caudate ratio distinguished SCA2 from PD patients, suggesting a more uniform nigrostriatal impairment in SCA2. Striatal DAT density of SCA2 patients correlated with the severity of cerebellar ataxia.
Collapse
|
158
|
Fujita M, Varrone A, Kim KM, Watabe H, Zoghbi SS, Seneca N, Tipre D, Seibyl JP, Innis RB, Iida H. Effect of scatter correction on the compartmental measurement of striatal and extrastriatal dopamine D2 receptors using [123I]epidepride SPET. Eur J Nucl Med Mol Imaging 2004; 31:644-54. [PMID: 14730406 DOI: 10.1007/s00259-003-1431-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2003] [Accepted: 11/21/2003] [Indexed: 10/26/2022]
Abstract
Prior studies with anthropomorphic phantoms and single, static in vivo brain images have demonstrated that scatter correction significantly improves the accuracy of regional quantitation of single-photon emission tomography (SPET) brain images. Since the regional distribution of activity changes following a bolus injection of a typical neuroreceptor ligand, we examined the effect of scatter correction on the compartmental modeling of serial dynamic images of striatal and extrastriatal dopamine D(2) receptors using [(123)I]epidepride. Eight healthy human subjects [age 30+/-8 (range 22-46) years] participated in a study with a bolus injection of 373+/-12 (354-389) MBq [(123)I]epidepride and data acquisition over a period of 14 h. A transmission scan was obtained in each study for attenuation and scatter correction. Distribution volumes were calculated by means of compartmental nonlinear least-squares analysis using metabolite-corrected arterial input function and brain data processed with scatter correction using narrow-beam geometry micro (SC) and without scatter correction using broad-beam micro (NoSC). Effects of SC were markedly different among brain regions. SC increased activities in the putamen and thalamus after 1-1.5 h while it decreased activity during the entire experiment in the temporal cortex and cerebellum. Compared with NoSC, SC significantly increased specific distribution volume in the putamen (58%, P=0.0001) and thalamus (23%, P=0.0297). Compared with NoSC, SC made regional distribution of the specific distribution volume closer to that of [(18)F]fallypride. It is concluded that SC is required for accurate quantification of distribution volumes of receptor ligands in SPET studies.
Collapse
|
159
|
Kim KM, Varrone A, Watabe H, Shidahara M, Fujita M, Innis RB, Iida H. Contribution of scatter and attenuation compensation to SPECT images of nonuniformly distributed brain activities. J Nucl Med 2003; 44:512-9. [PMID: 12679393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/01/2023] Open
Abstract
UNLABELLED Correction of scatter and attenuation is essential for quantitative SPECT. In this work, we evaluated the accuracy gained from a method of transmission-dependent convolution subtraction (TDCS) in the quantitation of activity that is highly concentrated in the striatum (STR). METHODS SPECT data were acquired from an (123)I-containing phantom with a constant activity in the STR but differing background (BKG) activities, so as to simulate various STR/BKG ratios (19.7:1, 9.7:1, 4.8:1, 1.9:1, and 1:1). In a study of healthy humans (n = 6), a transmission scan followed by an emission scan was performed 24 h after injection of (123)I-2beta-carbomethoxy-3beta-(4-iodophenyl)-tropane ((123)I-beta-CIT). All SPECT data was reconstructed with ordered-subset expectation maximization. TDCS was applied for scatter correction. Values of activity in the STR and occipital lobe (for BKG) were used to calculate binding potential V(3)" (= [STR - BKG]/BKG). The effect of SPECT collimator dependency on scatter correction was also evaluated for 6 collimators from 3 different SPECT cameras in the phantom experiment. RESULTS Scatter correction in the phantom experiment increased the measured values of STR activity (36.2%), resulting in a substantial increase in V(3)" (66.1%). Scatter and attenuation corrections with recovery correction showed an overall bias of -7.3% for the STR, -4.0% for BKG activity, and -7.8% for V(3)". TDCS corrections of phantom activities were relatively uniform for the 6 different collimators, with variabilities of <5.5% for the STR and <3.0% for BKG activities. TDCS correction of human (123)I-beta-CIT images was of a similar, although slightly larger, magnitude than for the phantom data, with increased V(3)" values of 9.4 +/- 2.3 and 4.9 +/- 0.6, with and without scatter correction, respectively. CONCLUSION The TDSC method significantly improved the accuracy of SPECT images with a nonuniform distribution of activity highly concentrated in central regions. The value of V(3)" was significantly increased in phantom and human data, with most of the improvement derived from an increase in STR activity. This scatter correction method was approximately equally useful with data from the 6 different collimators and is recommended for more accurate quantitation of nonuniformly distributed brain activities.
Collapse
|
160
|
Varrone A, Pappatà S, Caracò C, Soricelli A, Milan G, Quarantelli M, Alfano B, Postiglione A, Salvatore M. Voxel-based comparison of rCBF SPET images in frontotemporal dementia and Alzheimer's disease highlights the involvement of different cortical networks. Eur J Nucl Med Mol Imaging 2002; 29:1447-54. [PMID: 12397463 DOI: 10.1007/s00259-002-0883-5] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Characteristic patterns of regional cerebral blood flow (rCBF) reduction, as detected by technetium-99m hexamethylpropylene amine oxime ((99m)Tc-HMPAO) single-photon emission tomography (SPET), may help clinicians in differentiating patients with frontotemporal dementia (FTD) from those with Alzheimer's disease (AD). However, in some cases these patients may share common rCBF abnormalities and the visual analysis and/or the region of interest (ROI) approach may not sensitively detect more localised focal changes that could be more specific for each pathology. Recently, automated voxel-by-voxel statistical analysis of perfusion brain maps has been applied to SPET images. This method has the advantage of including the rCBF information for the whole brain for statistical analysis without any a priori hypothesis regarding the regions possibly involved. This could result in a better characterisation of rCBF differences in brain regions while also reducing the operator's subjectivity and the time required for data analysis. The purpose of this study was to apply such a technique to highlight the specific brain areas showing a relative functional involvement in FTD and AD. Thus, we compared the relative rCBF patterns obtained in eight FTD patients with those obtained in 21 AD patients using (99m)Tc-HMPAO SPET and statistical parametric mapping (SPM). When FTD patients were compared with AD patients, relatively lower rCBF was observed in right medial frontal cortex (BA 8, 9, 10), right anterior cingulate cortex (BA 32), right temporal cortex (BA 21/22), right orbitofrontal cortex (BA 11) and ventrolateral prefrontal cortex (BA 47); in BA 47 the reduction was evident bilaterally but was more marked on the right side. On the other hand, when AD patients were compared with FTD patients, a significant relative rCBF decrease was found in the bilateral superior parietal cortex (BA 7); this decrease was more extensive on the left side, where it also included the inferior parietal (BA 40), superior occipital (BA 19) and temporo-occipital regions (BA 39, 19). The results of this study confirm the preferential involvement of the frontotemporal regions in FTD patients and of the temporoparietal regions in AD patients. Furthermore, they highlight the networks that are more specifically impaired in these disorders and that could be implicated in the emotional-behavioural and cognitive disturbances that characterise FTD and AD respectively.
Collapse
|
161
|
Varrone A, Marek KL, Jennings D, Innis RB, Seibyl JP. [(123)I]beta-CIT SPECT imaging demonstrates reduced density of striatal dopamine transporters in Parkinson's disease and multiple system atrophy. Mov Disord 2001; 16:1023-32. [PMID: 11748733 DOI: 10.1002/mds.1256] [Citation(s) in RCA: 130] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
In vivo imaging of the dopamine transporter (DAT) with single photon emission computed tomography (SPECT) is a quantitative biomarker for Parkinson's disease (PD) onset and severity. This study has examined and compared the loss of striatal DAT in PD and multiple system atrophy (MSA) using [(123)I]beta-CIT SPECT imaging. One hundred and eighty-three patients (157 PD and 26 MSA) were studied. Clinical rating scales (Hoehn and Yahr stage and Unified Parkinson's Disease Rating Scale [UPDRS] scores) demonstrated that the MSA patients were more severely impaired than the PD patients. The striatal [(123)I]beta-CIT SPECT uptake was markedly reduced in both the PD and MSA groups. In addition, MSA patients showed more symmetric DAT loss compared with the PD patients, consistent with the more symmetric clinical motor dysfunction observed in MSA. While the loss of DAT was significantly reduced in all regions in both MSA and PD, comparison of the relative loss of the DAT did not significantly improve diagnostic accuracy in distinguishing between PD and MSA.
Collapse
|
162
|
Pace L, Nappi A, Imbriaco M, Cuocolo A, Varrone A, Romano M, Trimarco B, Salvatore M. [Relationship between exercise capacity and left ventricular function at rest in patients with heart insufficiency: radionuclide continuous monitoring of left ventricular function]. LA RADIOLOGIA MEDICA 2000; 100:120-5. [PMID: 11148876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/18/2023]
Abstract
PURPOSE To evaluate the relationship of systolic and diastolic function at rest to exercise capacity. MATERIAL AND METHODS Seventeen patients with ischemic heart failure were included in the study. Ambulatory left ventricular monitoring at rest and during upright exercise with combined analysis of pulmonary gas exchange was performed. Ejection fraction, end-diastolic volume, end-systolic volume, stroke volume, cardiac output, and peak filling rate were measured. RESULTS Significant positive correlations were found between rest ejection fraction and peak oxygen consumption (r = .60, p < .01), peak cardiac output (r = .77, p < .0001), peak stroke volume (r = .67, p < .005), and peak ejection fraction (r = .69, p < .005). On the other hand, peak filling rate at rest showed a significant inverse correlation with peak end-diastolic (r = -.48, p < .05) and end-systolic (r = -.66, p < .005) volumes. The patients were then subgrouped into two groups according to their rest ejection fraction (lower or higher than 40%). In the group with ejection fraction less than 40% a significant correlation was observed between rest ejection fraction and both peak stroke volume (r = .66, p < .05) and peak ejection fraction (r = .69, p < .05). In the same group of patients an inverse correlation was found between peak filling rate and both end-diastolic (r = -0.65, p < .05) and end-systolic (r = -.82, p < .005) volumes. CONCLUSIONS The results of the present study suggest that exercise capacity is related to left ventricular function at rest and that rest diastolic function might be a determinant of left ventricular function during exercise in patients with heart failure.
Collapse
|
163
|
Varrone A, Fujita M, Verhoeff NP, Zoghbi SS, Baldwin RM, Rajeevan N, Charney DS, Seibyl JP, Innis RB. Test-retest reproducibility of extrastriatal dopamine D2 receptor imaging with [123I]epidepride SPECT in humans. J Nucl Med 2000; 41:1343-51. [PMID: 10945525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023] Open
Abstract
UNLABELLED This study evaluated the test-retest reproducibility of D2 receptor quantification in the thalamus and temporal cortex using [123I]epidepride SPECT. METHODS Ten healthy volunteers (4 men, 6 women; age range, 19-46 y) underwent 2 SPECT studies (interval, 2-26 d) using a bolus-plus-constant-infusion paradigm (bolus-to-infusion ratio = 6 h; infusion time = 9 h). Plasma clearance (in liters per hour) and free fraction (f1) of the parent tracer were measured. Radioactivity (in becquerels per gram) in the thalamus, temporal cortex, and cerebellum were normalized to the infusion rate (in becquerels per hour). Normalized striatal radioactivity was also measured to assess reproducibility in regions with a high density of receptors and better counting statistics. The outcome measures obtained were V3 (receptor density [Bmax]/equilibrium dissociation constant [KD]), V3' (f1 x Bmax/KD), and RT (specific-to-nondisplaceable tissue ratio). RESULTS Test-retest variability and reliability (intraclass correlation coefficient) were 10.8% and 0.88, respectively, for plasma clearance and 15.3% and 0.77, respectively, for f1. The test-retest variability of brain-specific (target minus nondisplaceable) radioactivity was higher in the thalamus and temporal cortex than in the striatum, although reliability was comparable. Among the outcome measures, V3' showed better test-retest variability and reliability in the thalamus (13.3% and 0.75, respectively) and temporal cortex (13.4% and 0.86, respectively). CONCLUSION Brain radioactivity was the main source of variability for quantification of extrastriatal D2 receptors with [123I]epidepride. The reproducibility of outcome measures in extrastriatal regions was good. However, because receptor density was lower in extrastriatal regions than in the striatum, the counting statistics in these regions were low and reproducibility was affected by the higher test-retest variability of brain-specific radioactivity. Compared with V3 and V3', RT showed less test-retest variability in the thalamus and temporal cortex but lower reliability. Moreover, measurement of RT may be affected by the presence of potential lipophilic metabolites entering the brain.
Collapse
|
164
|
Guadagni S, Pizzutilli A, Mancini E, Varrone A, Palumbo G, Amicucci G, Perri S, Deraco M, Fiorentini G. Significance of duplex/colour Doppler sonography in hepatic arterial chemotherapy for patients with liver metastases from colorectal carcinoma. EUROPEAN JOURNAL OF SURGICAL ONCOLOGY 2000; 26:381-6. [PMID: 10873360 DOI: 10.1053/ejso.1999.0903] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
AIMS The aim of the study was to evaluate the importance of duplex/colour Doppler ultrasound in a protocol of hepatic regional chemotherapy, by measuring the blood flow in the hepatic artery, portal vein, hepatic veins, and inferior caval vein of patients with unresectable liver metastases from colorectal carcinoma. METHODS Thirty-nine consecutive subjects were selected for this study, including 21 patients who had unresectable histologically confirmed liver metastases from colorectal carcinoma (Group A), and 18 asymptomatic volunteers as normal controls (Group B). All subjects of Groups A and B were examined using duplex/colour Doppler sonography. After the ultrasound study, all patients of Group A were submitted to the administration of high dose mitomycin C into the hepatic artery, with concomitant detoxication of post-hepatic venous blood. RESULTS The mean value of the hepatic artery blood flow was significantly higher (P=0.0009) in liver metastases patients (361 ml/min, SEM=24 ml/min) than in normal controls (245 ml/min, SEM=20 ml/min). Also, the mean Doppler perfusion index was higher in liver metastases patients than in normal controls. For each patient of Group A, the total dose of mitomycin C to be infused was calculated based on the blood flow in the hepatic artery. In this way the concentration of mitomycin C in the hepatic artery was always greater than 3 microg/ml. The duration of detoxication was calculated based on the blood flow in the inferior caval vein. For two patients only, the blood flow was lower than 1000 ml/min, with the necessity to protract the duration of detoxication over 2 hours. CONCLUSIONS The measurement of the blood flow in hepatic vessels of patients with liver metastases seems to be very important in establishing the total dose of drug which has to be infused in hepatic arterial chemotherapy, and to determine the duration of concomitant detoxication of post-hepatic venous blood.
Collapse
|
165
|
Fujita M, Verhoeff NP, Varrone A, Zoghbi SS, Baldwin RM, Jatlow PA, Anderson GM, Seibyl JP, Innis RB. Imaging extrastriatal dopamine D(2) receptor occupancy by endogenous dopamine in healthy humans. Eur J Pharmacol 2000; 387:179-88. [PMID: 10650158 DOI: 10.1016/s0014-2999(99)00817-1] [Citation(s) in RCA: 46] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
The effect of endogenous dopamine on in vivo measurement of dopamine D(2) receptors in extrastriatal regions (thalamus and temporal cortex) was evaluated with single photon emission computed tomography and the high affinity ligand [123I]epidepride by comparing the binding potential before and after acute dopamine depletion. Dopamine depletion was achieved by per-oral administration of 5.5 g/70 kg body weight alpha-methyl-para-tyrosine given in 37 h. The alpha-methyl-para-tyrosine treatment increased the binding potential significantly in the temporal cortex (13+/-15%, P=0.036) but not in the thalamus (2+/-9%). The increase of the binding potential in the temporal cortex correlated strongly with the increase of dysphoric mood evaluated by the Positive and Negative Symptom Scale (PANSS) (rho=0.88, P=0.004). These results imply that [123I]epidepride, coupled with acute dopamine depletion might provide estimates of synaptic dopamine concentration.
Collapse
|
166
|
Varrone A, Soricelli A, Postiglione A, Salvatore M. Comparison between cortical distribution of I-123 iomazenil and Tc-99m HMPAO in patients with Alzheimer's disease using SPECT. Clin Nucl Med 1999; 24:660-5. [PMID: 10478740 DOI: 10.1097/00003072-199909000-00004] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To compare brain perfusion and synaptic density in Alzheimer's disease assessed using I-123 iomazenil SPECT with brain perfusion assessed using Tc-99m HMPAO SPECT. MATERIALS AND METHODS Early and delayed I-123 iomazenil SPECT images acquired 20 and 180 minutes after injection were compared with Tc-99m HMPAO SPECT studies acquired 15 to 20 minutes after injection in five patients with Alzheimer's disease. RESULTS Visual analysis of I-123 iomazenil images showed more severe (n = 4) and extensive (n = 3) defects than did Tc-99m HMPAO. Semiquantitative analysis was performed by normalizing the uptake of Tc-99m HMPAO and I-123 iomazenil in individual brain regions in the cerebellum and expressing these values as a ratio of the occipital regions. The analysis of brain regional ratios in Tc-99m HMPAO studies showed a low but significant correlation with ratios of delayed (r = 0.325, P < 0.05) images in the I-123 iomazenil studies. Furthermore, when compared with Tc-99m HMPAO, early (P < 0.01) and delayed mean ratios (P < 0.05) were significantly less in the frontal regions; early mean ratios were significantly less in the temporal regions (P < 0.05), and delayed (P < 0.05) mean ratios were significantly less in the parietal regions. CONCLUSIONS Tc-99m HMPAO images were better correlated with I-123 iomazenil images, indicating cortical synaptic density (delayed images). I-123 iomazenil SPECT in patients with Alzheimer's disease provided more sensitive information than Tc-99m HMPAO, allowing evaluation of brain perfusion and synaptic density.
Collapse
|
167
|
Nicolai E, Cuocolo A, Acampa W, Varrone A, Pace L, Salvatore M. Exercise-test Tc-99m tetrofosmin SPECT in patients with chronic ischemic left ventricular dysfunction: direct comparison with Ti-201 reinjection. J Nucl Cardiol 1999; 6:270-7. [PMID: 10385182 DOI: 10.1016/s1071-3581(99)90038-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
BACKGROUND This study was designed to compare the results of exercise-rest technetium-99m tetrofosmin single photon emission computed tomography (SPECT) with those of thallium-201 reinjection at rest after exercise-redistribution imaging in the same patients with chronic ischemic left ventricular (LV) dysfunction. METHODS Within 1 week, 33 patients with chronic myocardial infarction and LV dysfunction underwent exercise-rest tetrofosmin SPECT and Tl-201 reinjection at rest after exercise-redistribution imaging. In each patient, regional tetrofosmin and Tl-201 activity was quantitatively measured in 22 myocardial segments. Regional LV function was assessed in corresponding segments by echocardiography. RESULTS Agreement in the evaluation of regional perfusion status between tetrofosmin and Tl-201 imaging was observed in 78% of the 726 total segments, with a kappa value of 0.61. In segments with normal function at echocardiography (n = 436), no difference between Tl-201 and tetrofosmin uptake was observed. In hypokinetic segments (n = 138), exercise tetrofosmin uptake was lower (P < .01) as compared with exercise Tl-201 activity, whereas no difference was observed between tetrofosmin uptake at rest as compared with Tl-201 activity on redistribution and reinjection images. In segments with severe functional impairment (akinetic or dyskinetic, n = 152), tetrofosmin uptake on exercise images was reduced (P < .01) as compared with exercise Tl-201 activity; furthermore, tetrofosmin uptake at rest was lower (P < .01) as compared with Tl-201 activity on both redistribution and reinjection images. In these segments, concordance in the detection of myocardial viability between tetrofosmin and Tl-201 imaging was observed in 138 (91%) of the 152 segments, with a kappa value of 0.77. CONCLUSIONS In patients with chronic coronary artery disease and LV dysfunction quantitative exercise-rest tetrofosmin and Tl-201 reinjection SPECT provide similar information in the assessment of perfusion status and in the detection of myocardial viability.
Collapse
|
168
|
Pace L, Perrone-Filardi P, Mainenti P, Cuocolo A, Vezzuto P, Prastaro M, Varrone A, De Luca G, Soricelli A, Betocchi S, Chiariello M, Salvatore M. Identification of viable myocardium in patients with chronic coronary artery disease using rest-redistribution thallium-201 tomography: optimal image analysis. J Nucl Med 1998; 39:1869-74. [PMID: 9829573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023] Open
Abstract
UNLABELLED With the widely used 50% threshold, sensitivity is high, but specificity is low in detecting viable myocardium on 201Tl SPECT. In this study, we sought to identify the best threshold for semiquantitative 201Tl analysis. METHODS Rest-redistribution 201Tl SPECT was performed in 46 patients with chronic coronary artery disease before and after myocardial revascularization. Regional function was evaluated by two-dimensional echocardiography before and after myocardial revascularization using a 3-point scale (1 = normal, 2 = hypokinetic, 3 = a/dyskinetic). Myocardial segments with abnormal systolic function were defined as viable if the systolic function score decreased > or = 1 after myocardial revascularization. A second group of 12 patients with chronic coronary artery disease constituted the validation population. Sensitivity-specificity curves, as well as receiver operating characteristic curves, for rest and redistribution mages were generated by varying the 201Tl uptake threshold. RESULTS A 65% threshold uptake using resting images was found to be the best for detecting a/dyskinetic segments that improve after myocardial revascularization from those that do not improve. Sensitivity was lower with a 65% threshold (75%) than with a 50% threshold (90%, p < 0.05), but specificity was higher (76% versus 26%, p < 0.05) resulting in better accuracy (76% versus 57%, p < 0.05) and positive predictive value (77% versus 55%), while the negative predictive value was not different (69% versus 75%, p not significant). The area under the receiver operating characteristic curve was significantly (p < 005) larger for rest (0.80 +/- 0.05) as opposed to redistribution (0.72 +/- 0.05) images. Similar results were obtained in a subgroup of patients with low ejection fraction. Significant correlations between the percentage of revascularized viable segments and both the change in ejection fraction and in postrevascularization ejection fraction were found. When these findings were applied in the validation group, a gain in specificity, accuracy and positive predictive value was obtained with the 65% threshold compared with the 50% threshold. CONCLUSION This study demonstrated that analysis of resting images and use of the 65% 201Tl uptake threshold is preferable for separating viable from not viable dyssynergic myocardial segments in patients with chronic coronary artery disease.
Collapse
|
169
|
Della Morte AM, Storto G, Varrone A, Pace L, Cuocolo A, Perrone-Filardi P, Betocchi S, Chiariello M, Salvatore M. [Effects left ventricle asynchrony on systolic and diastolic function in patients with non-ischemic heart failure]. LA RADIOLOGIA MEDICA 1998; 96:68-72. [PMID: 9819621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
INTRODUCTION The asynchrony of the left ventricle--i.e., its nonuniform contraction and relaxation--is an important factor for left ventricular function. Heart failure is often related to abnormal systolic function, sometimes associated with a diastolic dysfunction. We studied the relationship of left ventricular asynchrony to left ventricular function in patients with nonischemic heart failure. MATERIAL AND METHODS Radionuclide angiography at rest was performed in 25 patients with nonischemic heart failure and in 26 age and sex matched normal subjects. In addition to ejection fraction and peak filling rate, two indices of left ventricular asynchrony were calculated: the coefficient of variation of regional time to end systole and the coefficient of variation of regional time to peak filling rate. These factors indicate how disperse are the regional values of time to end systole and of time to peak filling rate. In fact, the higher the value, the greater the asynchrony. RESULTS A significant (r = .46, p < .05) inverse correlation was found between the ejection fraction and the coefficient of variation of regional time to end systole in both the normal subjects and the heart failure patients, while the ejection fraction correlated significantly (r = .46, p < .05) with the coefficient of variation of regional time to peak filling rate only in the patients. Moreover, the peak filling rate was inversely correlated (r = .57, p < .05) with the coefficient of variation of regional time to peak filling rate in the heart failure patients but not in the normal subjects. CONCLUSIONS These results suggest that left ventricular systolic and diastolic asynchrony may contribute to impair left ventricular systolic and diastolic function in patients with nonischemic heart failure.
Collapse
|
170
|
Pace L, Perrone-Filardi P, Mainenti P, Prastaro M, Vezzuto P, Varrone A, Crisci T, Cuocolo A, Dellegrottaglie S, Piscione F, Chiariello M, Salvatore M. Combined evaluation of rest-redistribution thallium-201 tomography and low-dose dobutamine echocardiography enhances the identification of viable myocardium in patients with chronic coronary artery disease. EUROPEAN JOURNAL OF NUCLEAR MEDICINE 1998; 25:744-50. [PMID: 9662597 DOI: 10.1007/s002590050278] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The purpose of this study was to evaluate whether combined evaluation by discriminant analysis of rest-redistribution thallium-201 tomography and low-dose dobutamine echocardiography enhances the accuracy in identifying viable myocardium in patients with chronic coronary artery disease. Rest-redistribution 201Tl has high sensitivity but low specificity in identifying viable myocardium, while the opposite is true for low-dose dobutamine echocardiography. Forty-six patients underwent low-dose dobutamine echocardiography and rest-redistribution 201Tl tomography on the same day. Rest echocardiography was repeated at least 30 days (mean 40+/-20) after myocardial revascularization. Discriminant analysis was applied to the results of 201Tl tomography and dobutamine echocardiography to classify a/dyskinetic segments as viable or non-viable. In 92 a/dyskinetic segments that were revascularized, rest-redistribution 201Tl tomography yielded an accuracy of 75%, while the accuracy of dobutamine echocardiography was 70% (P<0.05). When discriminant analysis was used, the combined evaluation gave an accuracy of 83% (P<0.05 vs both tests). These findings demonstrate that low-dose dobutamine echocardiography and 201Tl imaging are useful and complementary techniques for identifying viable myocardium in patients with chronic coronary artery disease. Combined evaluation by discriminant analysis significantly improves accuracy, although the cost-effectiveness of such an approach remains to be determined.
Collapse
|
171
|
Acampa W, Cuocolo A, Sullo P, Varrone A, Nicolai E, Pace L, Petretta M, Salvatore M. Direct comparison of technetium 99m-sestamibi and technetium 99m-tetrofosmin cardiac single photon emission computed tomography in patients with coronary artery disease. J Nucl Cardiol 1998; 5:265-74. [PMID: 9669581 DOI: 10.1016/s1071-3581(98)90128-3] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
BACKGROUND Technetium 99m-labeled sestamibi and tetrofosmin tomography have shown high diagnostic accuracy in the detection of coronary artery disease (CAD). However, few data are available comparing sestamibi and tetrofosmin imaging in the same patients. The aim of the study was to determine the image quality of the two tracers and to compare the results of exercise sestamibi and tetrofosmin tomography in the same patients. METHODS The results of exercise-rest sestamibi and tetrofosmin myocardial tomography were compared in 32 patients with suspected or known CAD who underwent coronary angiography. Image quality was evaluated subjectively. Regional tracer distribution was visually assessed and quantitatively measured in 22 segments/patient. RESULTS At coronary angiography, 7 patients had normal coronary vessels, 11 single-vessel, and 14 multivessel CAD (> or =50% luminal stenosis). Image quality judged visually was comparable with the two tracers. Heart/lung and heart/liver ratios for sestamibi and tetrofosmin were not different. At visual analysis, 68% of the patients with CAD had abnormal findings with sestamibi and 76% with tetrofosmin (p = NS). At quantitative analysis, 92% of the patients with CAD had abnormal findings with sestamibi and 96% with tetrofosmin (p = NS). At both visual and quantitative analyses, sensitivity, specificity, and diagnostic accuracy in the detection of individual stenosed vessels were not different between the two tracers. Moreover, for both tracers sensitivity, specificity, and diagnostic accuracy in the detection of diseased vessels were significantly higher (all p < 0.05) at quantitative compared with visual analysis. Finally, defect size and severity were similar for the two tracers. CONCLUSIONS Exercise-rest sestamibi and tetrofosmin tomography yielded images of comparable quality and provided similar results in the identification of patients with CAD and in the detection of the individual stenosed coronary vessels.
Collapse
|
172
|
Soricelli A, Cuocolo A, Varrone A, Discepolo A, Tedeschi E, Mainenti PP, Grivet-Fojaja MR, Covelli EM, Postiglione A, Salvatore M. Technetium-99m-tetrofosmin uptake in brain tumors by SPECT: comparison with thallium-201 imaging. J Nucl Med 1998; 39:802-6. [PMID: 9591579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
UNLABELLED Thallium-201 is clinically used for the assessment of primary and recurrent brain tumors. The biologic properties of 201Tl that allow it to accumulate within the tumor cells render 201Tl useful in evaluating tumor malignancy, but its physical characteristics and nonroutine availability limits its use in some institutions, as compared to 99mTc-labeled compounds. The aim of this study was to assess the feasibility of using 99mTc-tetrofosmin for imaging brain tumors and to compare its uptake with that of 201Tl. METHODS Twenty-six patients with 27 intracranial masses were studied with SPECT. In the first group of seven patients (Group A), the timing for optimal acquisition of the 99mTc-tetrofosmin scan was assessed. In the second group of 19 patients (Group B), two sequential 201Tl (74-148 MBq intravenous) and 99mTc-tetrofosmin (740-925 MBq intravenous) studies were performed 20 min after tracer injection and compared. RESULTS In Group A, no significant difference in the tumor-to-background (T/B) ratio among the 20-, 40- and 120-min postinjection studies was observed. In Group B, the quality of reconstructed images with 99mTc-tetrofosmin, judged visually, was superior to that of 201Tl in 47% of all studies and was comparable in the remaining 53%. A significant relationship between 201Tl and 99mTc-tetrofosmin T/B ratio (r = 0.75, p < 0.01) was found. The T/B ratio of 99mTc-tetrofosmin was significantly higher than that of 201Tl (23.3 +/- 21.5 compared to 6.1 +/- 2.9, p < 0.005). CONCLUSION Technetium-99m-tetrofosmin is a suitable radiotracer for the imaging of intracranial lesions with SPECT. Moreover, a better definition of tumor margins and a higher contrast between neoplastic and normal brain tissue can be achieved.
Collapse
|
173
|
Pace L, Perrone-Filardi P, Mainenti PP, Prastaro M, Cuocolo A, Varrone A, Vezzuto P, Crisci T, Soricelli A, Piscione F, Chiariello M, Salvatore M. Effects of myocardial revascularization on regional thallium-201 uptake and systolic function in regions with reverse redistribution on tomographic thallium-201 imaging at rest in patients with chronic coronary artery disease. J Nucl Cardiol 1998; 5:153-60. [PMID: 9588667 DOI: 10.1016/s1071-3581(98)90198-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
OBJECTIVES There is growing evidence that myocardial segments with reverse redistribution are viable in patients with chronic coronary artery disease. The aim of this study was to assess the effects of myocardial revascularization on systolic function and thallium-201 uptake in such segments. METHODS Rest-redistribution thallium-201 tomography before and after myocardial revascularization was performed in 47 patients with chronic coronary artery disease. Regional function was evaluated by two-dimensional echocardiography before and after revascularization according to a 3-point scale (1 = normal, 2 = hypokinetic, 3 = a/dyskinetic). Improvement of dysfunctional segments was defined when systolic function score decreased > or =1 after revascularization. Reverse redistribution was defined as >8% decrease in relative thallium-201 uptake between rest and redistribution images. RESULTS Reverse redistribution was found in 27 (57%) of 47 patients, corresponding to 60 (11%) of 564 myocardial segments. Of such segments, 24 (40%) had normal systolic function, 19 (32%) were hypokinetic, and 17 (28%) were a/dyskinetic. Thirty-six segments underwent myocardial revascularization, and reverse redistribution was no longer present in 86% of them subsequent to the procedure. Of 26 dyssynergic segments with reverse redistribution subjected to revascularization, 18 (69%) improved at follow-up. CONCLUSIONS The findings of the present study indicate that reverse redistribution is a reversible phenomenon and is often associated with improvement of systolic function following revascularization in patients with chronic coronary artery disease.
Collapse
|
174
|
Nappi A, Cuocolo A, Imbriaco M, Nicolai E, Varrone A, Morisco C, Romano M, Trimarco B, Salvatore M. Ambulatory monitoring of left ventricular function: walk and bicycle exercise in congestive heart failure. J Nucl Med 1997; 38:948-53. [PMID: 9189148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
UNLABELLED The aim of this study was to assess changes in left ventricular (LV) function during 6-min walk test and cardiopulmonary exercise by continuous radionuclide monitoring in patients with congestive heart failure (CHF). METHODS Seventeen patients with CHF and 10 normal subjects underwent monitoring of LV function (Vest) during 6-min walk test and during bicycle exercise with combined analysis of pulmonary gas exchange. During cardiopulmonary exercise, all parameters of LV function were measured at rest, at the anaerobic threshold (AT) and at peak oxygen uptake (peak VO2). RESULTS In the normal subjects, during the walk test, heart rate (HR), ejection fraction (EF), end-diastolic volume (EDV), cardiac output (CO) and stroke volume (SV) significantly increased from rest to peak (all p < 0.001), while end-systolic volume (ESV) significantly decreased from rest to peak (p < 0.001). In patients with CHF, during the walk test, HR, EDV, ESV and CO significantly increased from rest to peak (p < 0.001), EF significantly decreased from rest to peak (p < 0.001) and SV did not show significant change. During cardiopulmonary exercise, normal subjects showed a significant increase in HR and CO, from rest to AT and from AT to the peak VO2 (p < 0.001). EF, EDV and SV significantly increased from rest to AT (p < 0.001), with no significant change from AT to peak VO2. ESV decreased from rest to AT (p < 0.001), showing no significant change from AT to peak VO2. In patients with CHF, HR, CO, ESV and EDV increased significantly from rest to AT (p < 0.001) and from AT to peak VO2 (p < 0.001). EF and SV did not show significant changes from rest to AT, showing a significant decrease from AT to peak VO2 (p < 0.001). CONCLUSION Vest can be used to evaluate cardiac responses during 6-min walk test and cardiopulmonary exercise in patients with CHF. In such patients, significant impairment of LV function is already present during submaximal physical exercise becoming more evident during the anaerobic phases of bicycle exercise.
Collapse
|
175
|
Soricelli A, Postiglione A, Grivet-Fojaja MR, Mainenti PP, Discepolo A, Varrone A, Salvatore M, Lassen NA. Reduced cortical distribution volume of iodine-123 iomazenil in Alzheimer's disease as a measure of loss of synapses. EUROPEAN JOURNAL OF NUCLEAR MEDICINE 1996; 23:1323-8. [PMID: 8781136 DOI: 10.1007/bf01367587] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Iodine-123 labelled iomazenil (IMZ) is a specific tracer for the GABAA receptor, the dominant inhibitory synapse of the brain. The cerebral distribution volume (Vd) of IMZ may be taken as a quantitative measure of these synapses in Alzheimer's disease (AD), where synaptic loss tends indiscriminately to affect all cortical neurons, albeit more so in some areas than in others. In this pilot study we measured Vd in six patients with probable AD and in five age-matched controls using a brain-dedicated single-photon emission tomography scanner allowing all cortical levels to be sampled simultaneously. Reduced values were found in all regions except in the occipital (visual) cortex. In particular, temporal and parietal cortex Vd was significantly (P<0.02) reduced: temporal Vd averaged 69 ml/ml in normals and 51 ml/ml in AD, and parietal Vd averaged 71 ml/ml in normals and 48 ml/ml in AD. These results accord well with emission tomographic studies of blood flow or labelled glucose. This supports the idea that while only measuring a subpopulation of synapses, the IMZ method reflects synaptic loss and hence functional loss in AD. The method constitutes an in vivo version of synaptic quantitation that in histopathological studies has been shown to correlate closely with the mental deterioration in AD.
Collapse
|