151
|
Lin X, Leung KH, Lin L, Lin L, Lin S, Leung CH, Ma DL, Lin JM. Determination of cell metabolite VEGF₁₆₅ and dynamic analysis of protein-DNA interactions by combination of microfluidic technique and luminescent switch-on probe. Biosens Bioelectron 2015; 79:41-7. [PMID: 26686922 DOI: 10.1016/j.bios.2015.11.089] [Citation(s) in RCA: 62] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2015] [Revised: 11/01/2015] [Accepted: 11/28/2015] [Indexed: 11/24/2022]
Abstract
In this paper, we rationally design a novel G-quadruplex-selective luminescent iridium (III) complex for rapid detection of oligonucleotide and VEGF165 in microfluidics. This new probe is applied as a convenient biosensor for label-free quantitative analysis of VEGF165 protein from cell metabolism, as well as for studying the kinetics of the aptamer-protein interaction combination with a microfluidic platform. As a result, we have successfully established a quantitative analysis of VEGF165 from cell metabolism. Furthermore, based on the principles of hydrodynamic focusing and diffusive mixing, different transient states during kinetics process were monitored and recorded. Thus, the combination of microfluidic technique and G-quadruplex luminescent probe will be potentially applied in the studies of intramolecular interactions and molecule recognition in the future.
Collapse
|
152
|
Sai J, Rogers M, Hockemeyer K, Wikswo JP, Richmond A. Study of Chemotaxis and Cell-Cell Interactions in Cancer with Microfluidic Devices. Methods Enzymol 2015; 570:19-45. [PMID: 26921940 DOI: 10.1016/bs.mie.2015.09.023] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Microfluidic devices have very broad applications in biological assays from simple chemotaxis assays to much more complicated 3D bioreactors. In this chapter, we describe the design and methods for performing chemotaxis assays using simple microfluidic chemotaxis chambers. With these devices, using real-time video microscopy we can examine the chemotactic responses of neutrophil-like cells under conditions of varying gradient steepness or flow rate and then utilize software programs to calculate the speed and angles of cell migration as gradient steepness and flow are varied. Considering the shearing force generated on the cells by the constant flow that is required to produce and maintain a stable gradient, the trajectories of the cell migration will reflect the net result of both shear force generated by flow and the chemotactic force resulting from the chemokine gradient. Moreover, the effects of mutations in chemokine receptors or the presence of inhibitors of intracellular signals required for gradient sensing can be evaluated in real time. We also describe a method to monitor intracellular signals required for cells to alter cell polarity in response to an abrupt switch in gradient direction. Lastly, we demonstrate an in vitro method for studying the interactions of human cancer cells with human endothelial cells, fibroblasts, and leukocytes, as well as environmental chemokines and cytokines, using 3D microbioreactors that mimic the in vivo microenvironment.
Collapse
|
153
|
Kondo E, Wada KI, Hosokawa K, Maeda M. Cryopreservation of adhered mammalian cells on a microfluidic device: Toward ready-to-use cell-based experimental platforms. Biotechnol Bioeng 2015; 113:237-40. [PMID: 26174812 DOI: 10.1002/bit.25704] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2015] [Revised: 06/08/2015] [Accepted: 07/07/2015] [Indexed: 11/08/2022]
Abstract
In this paper, we describe cryopreservation of mammalian cells in the adhered state on a microfluidic device (microdevice) for the first time. HeLa, NIH3T3, MCF-7, and PC12 cells were cultured on a microdevice in which a commercial polystyrene dish surface was used as the cell adhesion surface. Without cell-detaching treatment, the microdevice was stored in a freezer at -80°C. After thawing, we observed a greater number of live cells on the microdevice than those on a control culture dish. Although the effectiveness of the microdevice varied depending on the cell type and surface coating, the trend was consistent. We confirmed that the phenotype of the PC12 cells to differentiate into neuron-like cells was kept after the on-chip cryopreservation, and that the results of cytotoxicity test of cisplatin against the HeLa cells were essentially unchanged by the on-chip cryopreservation. These findings will open up a new possibility of ready-to-use cell-based experimental platforms.
Collapse
|
154
|
Quantitative analysis of Caenorhabditis elegans chemotaxis using a microfluidic device. Anal Chim Acta 2015; 887:155-162. [PMID: 26320797 DOI: 10.1016/j.aca.2015.07.036] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2014] [Revised: 04/24/2015] [Accepted: 07/17/2015] [Indexed: 11/24/2022]
Abstract
Caenorhabditis elegans, one of the widely studied model organisms, sense external chemical cues and perform relative chemotaxis behaviors through its simple chemosensory neuronal system. To study the mechanism underlying chemosensory behavior, a rapid and reliable method for quantitatively analyzing the worms' behaviors is essential. In this work, we demonstrated a microfluidic approach for investigating chemotaxis responses of worms to chemical gradients. The flow-based microfluidic chip was consisted of circular tree-like microchannels, which was able to generate eight flow streams containing stepwise chemical concentrations without the difference in flow velocity. Worms' upstream swimming into microchannels with various concentrations was monitored for quantitative analysis of the chemotaxis behavior. By using this microfluidic chip, the attractive and repellent responses of C. elegans to NaCl were successfully quantified within several minutes. The results demonstrated the wild type-like repellent responses and severely impaired attractive responses in grk-2 mutant animals with defects in calcium influx. In addition, the chemotaxis analysis of the third stage larvae revealed that its gustatory response was different from that in the adult stage. Thus, our microfluidic method provided a useful platform for studying the chemosensory behaviors of C. elegans and screening of chemosensation-related chemical drugs.
Collapse
|
155
|
Estrada-Leypon O, Moya A, Guimera A, Gabriel G, Agut M, Sanchez B, Borros S. Simultaneous monitoring of Staphylococcus aureus growth in a multi-parametric microfluidic platform using microscopy and impedance spectroscopy. Bioelectrochemistry 2015; 105:56-64. [PMID: 26004850 DOI: 10.1016/j.bioelechem.2015.05.006] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2014] [Revised: 04/22/2015] [Accepted: 05/04/2015] [Indexed: 11/30/2022]
Abstract
We describe the design, construction, and characterization of a scalable microfluidic platform that allows continuous monitoring of biofilm proliferation under shear stress conditions. Compared to other previous end-point assay studies, our platform offers the advantages of integration into multiple environments allowing simultaneous optical microscopy and impedance spectroscopy measurements. In this work we report a multi-parametric sensor that can monitor the growth and activity of a biofilm. This was possible by combining two interdigitated microelectrodes (IDuEs), and punctual electrodes to measure dissolved oxygen, K+, Na+ and pH. The IDuE has been optimized to permit sensitive and reliable impedance monitoring of Staphylococcus aureus V329 growth with two- and four-electrode measurements. We distinguished structural and morphological changes on intact cellular specimens using four-electrode data modeling. We also detected antibiotic mediated effects using impedance. Results were confirmed by scanning electrode microscopy and fluorescence microscopy after live/dead cell staining. The bacitracin mediated effects detected with impedance prove that the approach described can be used for guiding the development of novel anti-biofilm agents to better address bacterial infection.
Collapse
|
156
|
Lee Y, Lee JM, Bae PK, Chung IY, Chung BH, Chung BG. Photo-crosslinkable hydrogel-based 3D microfluidic culture device. Electrophoresis 2015; 36:994-1001. [PMID: 25641332 DOI: 10.1002/elps.201400465] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2014] [Revised: 12/20/2014] [Accepted: 01/14/2015] [Indexed: 12/21/2022]
Abstract
We developed the photo-crosslinkable hydrogel-based 3D microfluidic device to culture neural stem cells (NSCs) and tumors. The photo-crosslinkable gelatin methacrylate (GelMA) polymer was used as a physical barrier in the microfluidic device and collagen type I gel was employed to culture NSCs in a 3D manner. We demonstrated that the pore size was inversely proportional to concentrations of GelMA hydrogels, showing the pore sizes of 5 and 25 w/v% GelMA hydrogels were 34 and 4 μm, respectively. It also revealed that the morphology of pores in 5 w/v% GelMA hydrogels was elliptical shape, whereas we observed circular-shaped pores in 25 w/v% GelMA hydrogels. To culture NSCs and tumors in the 3D microfluidic device, we investigated the molecular diffusion properties across GelMA hydrogels, indicating that 25 w/v% GelMA hydrogels inhibited the molecular diffusion for 6 days in the 3D microfluidic device. In contrast, the chemicals were diffused in 5 w/v% GelMA hydrogels. Finally, we cultured NSCs and tumors in the hydrogel-based 3D microfluidic device, showing that 53-75% NSCs differentiated into neurons, while tumors were cultured in the collagen gels. Therefore, this photo-crosslinkable hydrogel-based 3D microfluidic culture device could be a potentially powerful tool for regenerative tissue engineering applications.
Collapse
|
157
|
Analysis of CCR7 mediated T cell transfectant migration using a microfluidic gradient generator. J Immunol Methods 2015; 419:9-17. [PMID: 25733353 DOI: 10.1016/j.jim.2015.02.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2014] [Revised: 02/07/2015] [Accepted: 02/18/2015] [Indexed: 12/11/2022]
Abstract
T lymphocyte migration is crucial for adaptive immunity. Manipulation of signaling molecules controlling cell migration combined with in-vitro cell migration analysis provides a powerful research approach. Microfluidic devices, which can precisely configure chemoattractant gradients and allow quantitative single cell analysis, have been increasingly applied to cell migration and chemotaxis studies. However, there are a very limited number of published studies involving microfluidic migration analysis of genetically manipulated immune cells. In this study, we describe a simple microfluidic method for quantitative analysis of T cells expressing transfected chemokine receptors and other cell migration signaling probes. Using this method, we demonstrated chemotaxis of Jurkat transfectants expressing wild-type or C-terminus mutated CCR7 within a gradient of chemokine CCL19, and characterized the difference in transfectant migration mediated by wild-type and mutant CCR7. The EGFP-tagged CCR7 allows identification of CCR7-expressing transfectants in cell migration analysis and microscopy assessment of CCR7 dynamics. Collectively, our study demonstrated the effective use of the microfluidic method for studying CCR7 mediated T cell transfectant migration. We envision this developed method will provide a useful platform to functionally test various signaling mechanisms at the cell migration level.
Collapse
|
158
|
Nery FC, da Hora CC, Yaqub U, Zhang X, McCarthy DM, Bhide PG, Irimia D, Breakefield XO. New methods for investigation of neuronal migration in embryonic brain explants. J Neurosci Methods 2015; 239:80-4. [PMID: 25291524 PMCID: PMC4268085 DOI: 10.1016/j.jneumeth.2014.09.028] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2014] [Revised: 09/24/2014] [Accepted: 09/25/2014] [Indexed: 01/19/2023]
Abstract
BACKGROUND Proper migration of neurons is essential for the formation and normal functioning of the nervous system. Defects in neuronal migration underlie a number of neurologic diseases in humans. Although cell migration is crucial for neural development, molecular mechanisms guiding neuronal migration remain to be elucidated fully. Newborn neurons from the embryonic medial ganglionic eminence (MGE) migrate a long distance dorsally in the developing brain, giving rise to several types of interneurons in the neocortex. NEW METHOD In this study, we developed an immunocytochemistry (ICC) protocol to stain neurons migrating out of the MGE explant embedded in Matrigel. We also established a protocol to efficiently transfect cells in MGE explants, achieving a transduction efficiency of more than 30%. COMPARISON WITH EXISTING METHOD In addition, we developed microfluidic chambers for explants that allow visualization of the vectorial migration of individual neurons from mouse embryonic MGE explants. Our microfluidic system allows monitoring of the distribution of cellular organelles (e.g. Golgi) within migrating neurons which have been stained with commercial molecular dyes or transfected with adeno-associated virus (AAV) expressing reporter proteins. CONCLUSION These methods provide new paradigms to study neuronal migration in real-time.
Collapse
|
159
|
Abstract
BACKGROUND Cells respond to a variety of external stimuli regulated by the environment conditions. Mechanical, chemical and biological factors are of great interest and have been deeply studied. Furthermore, mathematical and computational models have been rapidly growing over the past few years, permitting researches to run complex scenarios saving time and resources. Usually these models focus on specific features of cell migration, making them only suitable to study restricted phenomena. METHODS Here we present a versatile finite element (FE) cell-scale 3D migration model based on probabilities depending in turn on ECM mechanical properties, chemical, fluid and boundary conditions. RESULTS With this approach we are able to capture important outcomes of cell migration such as: velocities, trajectories, cell shape and aspect ratio, cell stress or ECM displacements. CONCLUSIONS The modular form of the model will allow us to constantly update and redefine it as advancements are made in clarifying how cellular events take place.
Collapse
|
160
|
Tourovskaia A, Fauver M, Kramer G, Simonson S, Neumann T. Tissue-engineered microenvironment systems for modeling human vasculature. Exp Biol Med (Maywood) 2014; 239:1264-71. [PMID: 25030480 DOI: 10.1177/1535370214539228] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The high attrition rate of drug candidates late in the development process has led to an increasing demand for test assays that predict clinical outcome better than conventional 2D cell culture systems and animal models. Government agencies, the military, and the pharmaceutical industry have started initiatives for the development of novel in-vitro systems that recapitulate functional units of human tissues and organs. There is growing evidence that 3D cell arrangement, co-culture of different cell types, and physico-chemical cues lead to improved predictive power. A key element of all tissue microenvironments is the vasculature. Beyond transporting blood the microvasculature assumes important organ-specific functions. It is also involved in pathologic conditions, such as inflammation, tumor growth, metastasis, and degenerative diseases. To provide a tool for modeling this important feature of human tissue microenvironments, we developed a microfluidic chip for creating tissue-engineered microenvironment systems (TEMS) composed of tubular cell structures. Our chip design encompasses a small chamber that is filled with an extracellular matrix (ECM) surrounding one or more tubular channels. Endothelial cells (ECs) seeded into the channels adhere to the ECM walls and grow into perfusable tubular tissue structures that are fluidically connected to upstream and downstream fluid channels in the chip. Using these chips we created models of angiogenesis, the blood-brain barrier (BBB), and tumor-cell extravasation. Our angiogenesis model recapitulates true angiogenesis, in which sprouting occurs from a "parent" vessel in response to a gradient of growth factors. Our BBB model is composed of a microvessel generated from brain-specific ECs within an ECM populated with astrocytes and pericytes. Our tumor-cell extravasation model can be utilized to visualize and measure tumor-cell migration through vessel walls into the surrounding matrix. The described technology can be used to create TEMS that recapitulate structural, functional, and physico-chemical elements of vascularized human tissue microenvironments in vitro.
Collapse
|
161
|
Abstract
Microfluidics-based lab-on-a-chips have many advantages, one of which is to provide physiologically relevant settings for cell biology experiments. Thus there is an ever increasing interest in their fabrication. Our goal is to construct three dimensional (3D) Controlled in vitro Microenvironments (CivMs) that mimic the in vivo microenvironments. Here, we present our optimized fabrication method that works for various lab-on-a-chip designs with a wide range of dimensions. The most crucial points are:While using one type of SU-8 photoresist (SU-2075), fine tuning of ramp, dwell time, spin speed, durations of soft bake, UV exposure and development allows fabrication of SU-8 masters with various heights from 40 to 600 μm. Molding PDMS (polydimethylsiloxane) at room temperature for at least two days instead of baking at higher temperatures prevents not only tears and bubbles in PDMS stamps but also cracks in the SU-8 master. 3D nature of the CivMs is ensured by keeping the devices inverted during gel polymerization.
Collapse
|
162
|
Microfluidic platform to evaluate migration of cells from patients with DYT1 dystonia. J Neurosci Methods 2014; 232:181-188. [PMID: 24880044 DOI: 10.1016/j.jneumeth.2014.05.027] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2014] [Revised: 05/11/2014] [Accepted: 05/20/2014] [Indexed: 01/05/2023]
Abstract
BACKGROUND Microfluidic platforms for quantitative evaluation of cell biologic processes allow low cost and time efficient research studies of biological and pathological events, such as monitoring cell migration by real-time imaging. In healthy and disease states, cell migration is crucial in development and wound healing, as well as to maintain the body's homeostasis. NEW METHOD The microfluidic chambers allow precise measurements to investigate whether fibroblasts carrying a mutation in the TOR1A gene, underlying the hereditary neurologic disease--DYT1 dystonia, have decreased migration properties when compared to control cells. RESULTS We observed that fibroblasts from DYT1 patients showed abnormalities in basic features of cell migration, such as reduced velocity and persistence of movement. COMPARISON WITH EXISTING METHOD The microfluidic method enabled us to demonstrate reduced polarization of the nucleus and abnormal orientation of nuclei and Golgi inside the moving DYT1 patient cells compared to control cells, as well as vectorial movement of single cells. CONCLUSION We report here different assays useful in determining various parameters of cell migration in DYT1 patient cells as a consequence of the TOR1A gene mutation, including a microfluidic platform, which provides a means to evaluate real-time vectorial movement with single cell resolution in a three-dimensional environment.
Collapse
|
163
|
Development of an aptamer-based impedimetric bioassay using microfluidic system and magnetic separation for protein detection. Biosens Bioelectron 2014; 59:106-11. [PMID: 24709326 DOI: 10.1016/j.bios.2014.03.015] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2013] [Revised: 03/06/2014] [Accepted: 03/07/2014] [Indexed: 12/20/2022]
Abstract
An aptamer-based impedimetric bioassay using the microfluidic system and magnetic separation was developed for the sensitive and rapid detection of protein. The microfluidic impedance device was fabricated through integrating the gold interdigitated array microelectrode into a flow cell made of polydimethylsiloxane (PDMS). Aptamer modified magnetic beads were used to capture and separate the target protein, and concentrated into a suitable volume. Then the complexes were injected into the microfluidic flow cell for impedance measurement. To demonstrate the high performance of this novel detection system, thrombin was employed as the target protein. The results showed that the impedance signals at the frequency of 90 kHz have a good linearity with the concentrations of thrombin in a range from 0.1 nM to 10nM and the detection limit is 0.01 nM. Compared with the reported impedimetric aptasensors for thrombin detection, this method possesses several advantages, such as the increasing sensitivity, improving reproducibility, reducing sample volume and assay time. All these demonstrate the proposed detection system is an alternative way to enable sensitive, rapid and specific detection of protein.
Collapse
|
164
|
Mai J, Abhyankar VV, Piccini ME, Olano JP, Willson R, Hatch AV. Rapid detection of trace bacteria in biofluids using porous monoliths in microchannels. Biosens Bioelectron 2013; 54:435-41. [PMID: 24316449 DOI: 10.1016/j.bios.2013.11.012] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2013] [Revised: 10/31/2013] [Accepted: 11/01/2013] [Indexed: 11/18/2022]
Abstract
We present advancements in microfluidic technology for rapid detection of as few as 10 rickettsial organisms in complex biological samples. An immuno-reactive filter, macroporous polyacrylamide monolith (PAM), fabricated within a microfluidic channel enhances solid-phase immuno-capture, staining and detection of targeted bacteria. Bacterial cells in samples flowing through the channel are forced to interact with the PAM filter surface due to size exclusion, overcoming common transport and kinetic limitations for rapid (min), high-efficiency (~100%) capture. In the process, targeted cells in sample volumes of 10 μl to >100 μl are concentrated within a sub-50 nl region at the PAM filter edge in the microchannel, thus concentrating them over 1000-fold. This significantly increases sensitivity, as the hydrophilic PAM also yields low non-specific immuno-fluorescence backgrounds with samples including serum, blood and non-targeted bacteria. The concentrated target cells are detected using fluorescently-labeled antibodies. With a single 2.0×2.0×0.3 mm PAM filter, as few as 10 rickettsial organisms per 100 µl of lysed blood sample can be analyzed within 60 min, as compared to hours or even days needed for conventional detection methods. This method is highly relevant to rapid, multiplexed, low-cost point of care diagnostics at early stages of infection where diagnostics providing more immediate and actionable test results are needed to improve patient outcomes and mitigate potential natural and non-natural outbreaks or epidemics of rickettsial diseases.
Collapse
|
165
|
Determination of Acid β-Galactosidase Activity: Methodology and Perspectives. Indian J Clin Biochem 2013; 29:57-62. [PMID: 24478550 DOI: 10.1007/s12291-013-0318-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2013] [Accepted: 03/19/2013] [Indexed: 10/27/2022]
Abstract
Early, accurate diagnosis of lysosomal storage disorders is a major challenge, even for trained specialists. Finding innovative, accurate diagnostic methods, and high throughput, cost-effective tools are crucial to medical progress and will contribute to improved quality of life. The goal of this work was to improve currently used protocols to determine activity of acid β-galactosidase, and discuss the possibility analysing lysosomal enzymes with microfluidic systems. A principle of the determination of β-galactosidase activity was fluorometric measurement of a deprotonated form of 4-methylumbelliferone released in the enzymatic reaction. Measurements were performed using Jurkat T cells as a source of the enzyme. We observed the temperature-dependent substrate inhibition effect and determined the substrate (4-MU-β-d-galactopyranoside) concentration which should be used to determine acid β-galactosidase activity at 37 °C (0.8 mM) and at room temperature (0.6 mM). We proved that the sample incubation time may be significantly reduced to only a few minutes. We also showed that the amount of alkaline buffer used to stop the enzymatic reaction may be minimized and even, in some cases, eliminated. The presented results show how the sensitivity of the available methods to diagnose patients suffer from gangliosidosis GM1 or Morquio B disease can be improved. The proposed method may be easily implemented with microfluidic systems, which currently are promising tools for point-of-care applications.
Collapse
|
166
|
Landry ZC, Giovanonni SJ, Quake SR, Blainey PC. Optofluidic cell selection from complex microbial communities for single-genome analysis. Methods Enzymol 2013; 531:61-90. [PMID: 24060116 DOI: 10.1016/b978-0-12-407863-5.00004-6] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Genetic analysis of single cells is emerging as a powerful approach for studies of heterogeneous cell populations. Indeed, the notion of homogeneous cell populations is receding as approaches to resolve genetic and phenotypic variation between single cells are applied throughout the life sciences. A key step in single-cell genomic analysis today is the physical isolation of individual cells from heterogeneous populations, particularly microbial populations, which often exhibit high diversity. Here, we detail the construction and use of instrumentation for optical trapping inside microfluidic devices to select individual cells for analysis by methods including nucleic acid sequencing. This approach has unique advantages for analyses of rare community members, cells with irregular morphologies, small quantity samples, and studies that employ advanced optical microscopy.
Collapse
|
167
|
Kim J, Olsen T, Zhuang X, Luo J, Yao J, Stojanovic M, Lin Q. Formation and Stimuli-Directed Migration of D. discoideum Slugs in Microchips. J Med Biol Eng 2013; 33:263-268. [PMID: 33551700 PMCID: PMC7861487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
This paper presents a microfluidic device that geometrically constrains the development of individual Dictyostelium discoideum cells into multicellular organisms (slugs). A microchip for the stimuli-directed migration of slugs is also presented. To demonstrate the formation of slugs in a predetermined shape, a microchip is designed to confine the slugs in the vertical direction. In the microchip, sufficient oxygen is supplied to the cells via a membrane, allowing the formation and adaptation of slugs to the shape of the channel. In addition, the manipulation of slug migration direction in a microchip via external stimuli, such as light and temperature gradients, that induce phototaxis and thermotaxis of slugs, respectively, is demonstrated. To direct slug migration with external stimuli, an optical fiber is used for phototaxis and an electrical wire heater is used for thermotaxis. Experimental results show slug formation in a predefined geometry in the microchip, suggesting that this chip is potentially useful for understanding the relationship between the shape and function of cells or tissue. The controlled migration of slugs demonstrated in the microchips can potentially be employed in biologically based microactuators or microrobots.
Collapse
|
168
|
Liu Y, Wang JC, Ren L, Tu Q, Liu WM, Wang XQ, Liu R, Zhang YR, Wang JY. Microfluidics-based assay on the effects of microenvironmental geometry and aqueous flow on bacterial adhesion behaviors. J Pharm Anal 2011; 1:175-183. [PMID: 29403696 PMCID: PMC5760795 DOI: 10.1016/j.jpha.2011.06.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2011] [Accepted: 06/08/2011] [Indexed: 11/28/2022] Open
Abstract
A new microfluidic system with four different microchambers (a circle and three equilateral concave polygons) was designed and fabricated using poly(dimethylsiloxane) (PDMS) and the soft lithography method. Using this microfluidic device at six flow rates (5, 10, 20, 30, 40, and 50 μL/h), the effects of microenvironmental geometry and aqueous flow on bacterial adhesion behaviors were investigated. Escherichia coli HB101 pGLO, which could produce a green fluorescent protein induced by l-arabinose, was utilized as the model bacteria. The results demonstrated that bacterial adhesion was significantly related to culture time, microenvironment geometry, and aqueous flow rates. Adhered bacterial density increased with the culture time. Initially, the adhesion occurred at the microchamber sides, and then the entire chamber was gradually covered with increased culture time. Adhesion densities in the side zones were larger than those in the center zones because of the lower shearing force in the side zone. Also, the adhesion densities in the complex chambers were larger than those in the simple chambers. At low flow rates, the orientation of adhered bacteria was random and disorderly. At high flow rates, bacterial orientation became close to the streamline and oriented toward the flow direction. All these results implied that bacterial adhesion tended to occur in complicated aqueous flow areas. The present study provided an on-chip flow system for physiological behavior of biological cells, as well as provided a strategic cue for the prevention of bacterial infection and biofilm formation.
Collapse
|