176
|
Ackley KL, Day JA, Caruso JA. Separation of metalloporphyrins by capillary electrophoresis with UV detection and inductively coupled plasma mass spectrometric detection. J Chromatogr A 2000; 888:293-8. [PMID: 10949495 DOI: 10.1016/s0021-9673(00)00516-1] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Vitamin B12, cobalt protoporphyrin, manganese protoporphyrin, and zinc protoporphyrin were separated using capillary electrophoresis, and a comparison was made between detection with inductively coupled plasma mass spectrometry (ICP-MS) and UV detection. Absolute limits of detection were slightly better with ICP-MS detection than with UV detection, but for both methods absolute detection limits were in the picogram range. The migration times of the analytes decreased by several minutes when ICP MS detection was employed, and this phenomenon was believed to be a result of a "suction effect" that developed when the CE capillary was interfaced to the ICP-MS nebulizer. However, the resolution between species containing the same metal atom was not altered significantly, and the separation was completed in much less time relative to separations performed with UV detection.
Collapse
|
177
|
Vela NP, Caruso JA. Element selective detection for supercritical-fluid chromatography. JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS 2000; 43:45-58. [PMID: 10869666 DOI: 10.1016/s0165-022x(00)00091-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
This manuscript describes the use of Supercritical-Fluid Chromatography (SFC) with plasma spectrometric detection for the analysis of organometallics. An introduction on the principles and characteristics of Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) and Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) is included, along with a discussion about requirements for coupling SFC to plasma detection and the different approaches for interfacing SFC to ICP. The last part of this review paper provides a comprehensive description of SFC-ICP applications for the analysis of organometallics containing iron, silicon, tin, chromium, arsenic, lead, mercury and antimony.
Collapse
|
178
|
Sutton KL, Sutton RM, Stalcup AM, Caruso JA. A comparison of vancomycin and sulfated beta-cyclodextrin as chiral selectors for enantiomeric separations of selenoamino acids using capillary electrophoresis with UV absorbance detection. Analyst 2000; 125:231-4. [PMID: 10820888 DOI: 10.1039/a908558k] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The enantiomeric separation of three selenoamino acids, D,L-selenomethionine, D,L-selenoethionine and D,L-selenocystine is described. Both sulfated beta-cyclodextrin and vancomycin have been successfully used to separate all enantiomers of the compounds with UV detection. Reproducible separations, in terms of peak area and migration time were obtained using sulfated beta-cyclodextrin with reversed polarity and UV detection. With vancomycin as a chiral selector, reversed polarity was found to be more reproducible than positive polarity in terms of peak migration times.
Collapse
|
179
|
Sutton KL, Ponce de Leon CA, Ackley KL, Sutton RM, Stalcup AM, Caruso JA. Development of chiral HPLC for selenoamino acids with ICP-MS detection:application to selenium nutritional supplements. Analyst 2000; 125:281-6. [PMID: 10866603 DOI: 10.1039/a907847i] [Citation(s) in RCA: 54] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The enantiomeric separation of three underivatized seleno-amino acids, D,L-selenocystine, and D,L-selenomethionine, and D,L-selenomethionine, with UV and ICP-MS detection is described. An HPLC column with a chiral crown ether stationary phase and a mobile phase of 0.10 M HCIO4 was used. Absolute detection limits obtained with UV detection ranged from 34.5 to 47.1 ng whereas those obtained with the plasma detector were ca. 40-400 times better. The separations with either detector were good, with the little detector effect on the resolution. Ten commercially available dietary selenium supplements were analyzed using the chiral column to identify and quantify the selenium species present with both detection modes. Selenium species were easily identified using ICP-MS detection, whereas UV detection was not viable because of interferences from the sample matrix and inadequate sensitivity. Selenium species that were unretained using the chiral column were identified using anion exchange chromatography. Total amounts in the samples were also measured using a conventional digestion and enzymatic digestion with ICP-MS detection.
Collapse
|
180
|
Day JA, Sutton KL, Caruso JA, Soman RS. A comparison of capillary electrophoresis using indirect UV absorbance and ICP-MS detection with a self-aspirating nebulizer interface. Analyst 2000. [DOI: 10.1039/a910268j] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
181
|
Caruso JA, Laird DW, Batist G. Role of HSP90 in mediating cross-talk between the estrogen receptor and the Ah receptor signal transduction pathways. Biochem Pharmacol 1999; 58:1395-403. [PMID: 10513983 DOI: 10.1016/s0006-2952(99)00225-7] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Tetrachlorodibenzo-p-dioxin (TCDD)-mediated gene transactivation via the Ah receptor (AhR) has been shown to be dependent upon estrogen receptor (ER) expression in human breast cancer cells. We have investigated the 90-kDa heat shock protein (HSP90) as a mediator of cross-talk between the AhR and the ER signal transduction pathways. The effect of HSP90 overexpression on receptor activity was determined by transient transfection assays using a HSP90 expression vector. Ligand-inducible gene expression was inhibited when the HSP90 expression vector was cotransfected with a TCDD-responsive reporter plasmid. However, overexpression of HSP90 did not block induction of an estrogen-responsive reporter plasmid. To determine whether ER facilitates AhR signaling through its ability to squelch HSP90, two vectors expressing protein products that bind HSP90 were transfected into MDA-MB-231 cells. Introduction of (i) He11, an ER deletion mutant that does not bind DNA, and (ii) the ligand-binding domain of human AhR, both led to increased basal and TCDD-inducible CYP1A1 expression. Finally, the subcellular distribution of HSP90 was investigated in human breast cancer cell lines. These studies showed HSP90 to be primarily cytoplasmic in ER-positive cell lines, whereas in matched ER-negative cell lines HSP90 was distributed equally between the cytoplasm and nucleus. Taken together, these results demonstrate that HSP90 can regulate AhR activity in vivo, and that Ah-responsiveness is dependent upon cellular ER content through a mechanism that involves HSP90.
Collapse
|
182
|
Abstract
The technique of coupling liquid chromatography to inductively plasma mass spectrometry (ICP-MS) is reviewed. A brief introduction to the ICP-MS instrument is given as well as methods to couple the two analytical instruments together. The various types of LC that have been used with ICP-MS detection are discussed and advantages over traditional methods of detection are highlighted, such as the improvements in sensitivity and selectivity. Several applications that have been described in the literature are reviewed. An outlook for the future of LC-ICP-MS, particularly with regard to elemental speciation is given.
Collapse
|
183
|
Caruso JA, Batist G. Divergent mechanisms for loss of Ah-responsiveness in benzo[a]pyrene- and adriamycinR-resistant MCF-7 cells. Biochem Pharmacol 1999; 57:1253-63. [PMID: 10230769 DOI: 10.1016/s0006-2952(99)00041-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
The intracellular aryl hydrocarbon receptor (AhR) mediates signal transduction by environmental pollutants such as 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) and benzo[a]pyrene by functioning as a ligand-activated transcription factor. We have investigated AhR signaling in sublines of the human breast cancer cell line MCF-7 selected for resistance to AdriamycinR (AdrR) and benzo[a]pyrene (BP(R)). Previously we reported that AdrR cells have a loss of estrogen receptor (ER) expression and are Ah-nonresponsive. Here we show that AhR mRNA and protein are expressed at normal levels in AdrR cells, and the activated AhR complex is functionally capable of binding a xenobiotic responsive element. In MCF-7 cells AhR was depleted to 15% of normal levels after 4 hr TCDD treatment; however, 45% of AhR remained in AdrR cells during this time course. In BP(R) cells AhR mRNA levels were found to be decreased relative to wild-type cells, which led to decreased AhR protein levels and DNA-binding activity. Cellular ER content has been shown to correlate with Ah-responsiveness in human breast cancer cell lines. BP(R) cells were found to be ER-positive, although chronic (BP(R) cells) and acute (24 hr) exposure to benzo[a]pyrene led to significantly lower ER protein levels in MCF-7 cells. We conclude that loss of Ah-responsiveness occurs by different mechanisms in xenobiotic-resistant MCF-7 sublines: AhR mRNA is down-regulated in BP(R) cells, whereas AdrR cells are deficient in AhR signaling by a mechanism unrelated to AhR expression and activity.
Collapse
|
184
|
B’Hymer C, M. C. Sutton R, L. Sutton K, A. Caruso J. The use of sol–gel frits to minimize suction effects in capillary electrophoresis–nebulizer interfaces for plasma spectrometry†. ACTA ACUST UNITED AC 1999. [DOI: 10.1039/a905088d] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
185
|
Gbatu TP, Ceylan O, Sutton KL, Rubinson JF, Caruso JA, Mark Jr HB. Electrochemical control of solid phase micro-extraction using unique conducting polymer coated fibers. ACTA ACUST UNITED AC 1999. [DOI: 10.1039/a901991j] [Citation(s) in RCA: 68] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
186
|
Ackley KL, Day JA, Sutton KL, Caruso JA. Investigation of problems associated with the determination of iodine in glacial acetic acid samples using flow injection analysis-inductively coupled plasma-mass spectrometry†. ACTA ACUST UNITED AC 1999. [DOI: 10.1039/a904296b] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
187
|
|
188
|
Belkin M, Waggoner JW, Caruso JA. The potential of a modified rf glow discharge source for enhanced elemental speciation studies. ACTA ACUST UNITED AC 1998. [DOI: 10.1039/a805387a] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
189
|
Sutton K, Sutton RM, Caruso JA. Inductively coupled plasma mass spectrometric detection for chromatography and capillary electrophoresis. J Chromatogr A 1997; 789:85-126. [PMID: 9440286 DOI: 10.1016/s0021-9673(97)00970-9] [Citation(s) in RCA: 118] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Inductively coupled plasma mass spectrometry (ICP-MS) is now a well established detection technique for liquid chromatography, gas chromatography, supercritical fluid chromatography and capillary electrophoresis. A review of the literature with particular regard to ICP-MS as a chromatographic and capillary electrophoretic detector is presented. The various modes of chromatography and capillary electrophoresis are discussed and practical descriptions for hyphenating the techniques with the ICP mass spectrometer are given. Sample introduction systems and data acquisition methods are reviewed along with the numerous applications of ICP-MS as a chromatographic detector. In addition, alternative plasma sources, such as the atmospheric and reduced pressure helium microwave-induced plasmas for chromatographic detection are described.
Collapse
|
190
|
Zoorob GK, Caruso JA. Speciation of chromium dyes by high-performance liquid chromatography with inductively coupled plasma mass spectrometric detection. J Chromatogr A 1997; 773:157-62. [PMID: 9228796 DOI: 10.1016/s0021-9673(97)00074-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
High-performance liquid chromatography (HPLC) coupled to inductively coupled plasma mass spectrometry (ICP-MS) was employed for the separation and detection of chromium species in azo dyes, Acid blue 158 and Acid Blue 193; mainly Cr(III) and Cr(VI). The dyes were first analyzed for total metal content using ICP-MS and their stability in solution was studied by measuring their absorbance through a range of pH values. Then an isocratic chromatographic method employing reversed-phase liquid chromatography with mass spectrometric detection was developed. Applying this method to the separation of these dyes, the absolute detection limits of Acid Blue 158 and 193 were 1 and 5 ng respectively. Additionally, Acid Blue 158 did not contain any chromium species. On the other hand, Acid Blue 193 contained uncomplexed and potentially bioavailable Cr(III). Acid Blue 193 did not have any toxic Cr(VI) present in the samples.
Collapse
|
191
|
Alpert LC, Schecter RL, Berry DA, Melnychuk D, Peters WP, Caruso JA, Townsend AJ, Batist G. Relation of glutathione S-transferase alpha and mu isoforms to response to therapy in human breast cancer. Clin Cancer Res 1997; 3:661-7. [PMID: 9815734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
Glutathione S-transferase (GST) represents a multifunctional enzyme family consisting of four known cytosolic isoforms (alpha, mu, pi, and Phi) that detoxify a variety of xenobiotic chemicals and may confer resistance to both chemotherapeutic drugs and carcinogens in various experimental models. GST-pi has already been extensively studied in clinical specimens, including breast cancer. We studied the immuno-histochemical distribution and relative immunopositivity of GST-alpha and GST-mu, based on a grading system for immunointensity, in samples of 51 neoplastic and 46 normal breast samples and 12 lymph node metastases from patients treated with intensive chemotherapy and bone marrow transplant. In normal breast tissue, GST-alpha localized predominantly to the cytoplasm of scattered cells lining the luminal aspects of the ducts. Occasional cells showed both cytoplasmic and nuclear GST-alpha immunoreactivity. GST-mu was stained in myoepithelial cells preferentially as well as in occasional ductal cells (including apocrine epithelium), vascular smooth muscle, and plasma cells. GST-alpha and GST-mu were detected in 22 of 51 (43%) and 24 of 48 (50%) invasive cancers, respectively. In paired samples of normal and malignant tissue from the same patient, GST-alpha immunostaining in cancers was significantly less intense compared to that of normal breast tissue in 13 of 41 (32%) cases. No such trend was found for GST-mu in paired samples. Neither GST-alpha nor GST-mu immunopositivity in tumor or nonneoplastic breast was found to correlate with relapse-free or overall survival in this clinical context; however, the apparent decreased expression of GST-alpha in malignant versus normal breast epithelial cells could have important implications in breast carcinogenesis.
Collapse
|
192
|
Kumar UT, Vela NP, Caruso JA. Multi-element detection of organometals by supercritical fluid chromatography with inductively coupled plasma mass spectrometric detection. J Chromatogr Sci 1995; 33:606-10. [PMID: 7593407 DOI: 10.1093/chromsci/33.11.606] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Organometal compounds of arsenic, antimony, and mercury are speciated using supercritical fluid chromatography with inductively coupled plasma mass spectrometric (ICP-MS) detection. The multi-element capability of ICP-MS for transient signals is examined by detecting five compounds containing all three elements in a single chromatographic injection. The results obtained are compared with those obtained from flame-ionization detection (FID). Trimethyl arsine is not distinguished from the solvent peak when FID is used because it coelutes with the solvent, whereas trimethyl arsine is detected when ICP-MS is used because of its element-selective nature. The detection limits obtained by ICP-MS are 2-3 orders of magnitude lower than those obtained by FID. Determination of isotope abundance is also demonstrated for triphenyl antimony and diphenyl mercury compounds.
Collapse
|
193
|
Byrdy FA, Olson LK, Vela NP, Caruso JA. Chromium speciation by anion-exchange high-performance liquid chromatography with both inductively coupled plasma atomic emission spectroscopic and inductively coupled plasma mass spectrometric detection. J Chromatogr A 1995; 712:311-20. [PMID: 7581851 DOI: 10.1016/0021-9673(95)00528-u] [Citation(s) in RCA: 64] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Development of a new method for the determination of Cr(III) and Cr(VI) is described. Anion-exchange high-performance liquid chromatography (HPLC) was used to separate Cr(III) and Cr(VI) with on-line detection by inductively coupled plasma atomic emission spectroscopy (ICP-AES) at 2766 A in preliminary studies, and inductively coupled plasma mass spectrometry (ICP-MS) with single-ion monitoring at m/z 52 and m/z 53 for final work. A mobile phase consisting of ammonium sulfate and ammonium hydroxide was used, and a simple chelation procedure with EDTA was followed to stabilize the Cr(III) species in standard solutions. ICP-MS results indicated the feasibility of using chromium isotope m/z 53 instead of the more abundant m/z 52 isotope due to a high mobile-phase background most significantly from the SO+ polyatomic interference. The absolute detection limits based on peak-height calculations were 40 pg for Cr(III) and 100 pg for Cr(VI) in aqueous media by HPLC-ICP-MS. The linear dynamic range extended from 5 ppb (ng/ml) to 1 ppm (micrograms/ml) for both species. By HPLC-ICP-AES, detection limits were 100 ng for Cr(III) and 200 ng for Cr(VI). Cr(III) was detected in NIST-SRM 1643c (National Institute of Standards and Technology-Standard Reference Material, Trace Elements in Water) by HPLC-ICP-MS at the 20 ppb level.
Collapse
|
194
|
Ding H, Wang J, Dorsey JG, Caruso JA. Arsenic speciation by micellar liquid chromatography with inductively coupled plasma mass spectrometric detection. J Chromatogr A 1995; 694:425-31. [PMID: 7535627 DOI: 10.1016/0021-9673(94)01085-s] [Citation(s) in RCA: 62] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Four environmentally and biologically important arsenic species, dimethylarsenic acid (DMA), monomethylarsonic acid (MMA), As(III) and As(V) are separated by micellar liquid chromatography. Linear dynamic ranges for the four species are three orders of magnitude and detection limits are in the picogram range with inductively coupled plasma mass spectrometric (ICP-MS) detection. This paper discussed in detail the development of the chromatographic conditions. The micellar mobile phase, which consisted of 0.05 M cetyltrimethylammonium bromide, 10% propanol and 0.02 M borate buffer, showed good compatibility with ICP-MS. This method allowed direct injection of urine samples onto the chromatographic system without extensive pretreatment and presented no interference from chlorine in the matrix. Detection limits are comparable with other LC-ICP-MS studies. An SRM urine sample was used to demonstrate the applicability of this technique to "real-life" situations. Results indicated that DMA, MMA and As(V) were present in the urine sample.
Collapse
|
195
|
Tomlinson MJ, Lin L, Caruso JA. Plasma mass spectrometry as a detector for chemical speciation studies. Analyst 1995; 120:583-9. [PMID: 7741220 DOI: 10.1039/an9952000583] [Citation(s) in RCA: 54] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Inductively coupled plasma mass spectrometry (ICP-MS), when coupled with the unique separating power of various chromatographic techniques, allows the detection of various elements at ultra-trace levels. The investigation of various toxic elements of environmental concern coupling relatively recent techniques, such as supercritical fluid chromatography (SFC) and capillary zone electrophoresis (CZE), to ICP-MS, is discussed. Comparisons have been made with detection limits obtained by using the flame ionization detector. The conventional technique of liquid chromatography for the speciation of vanadium, chromium and nickel is also discussed.
Collapse
|
196
|
Byrdy FA, Caruso JA. Trace metals speciation by HPLC with plasma source mass spectrometry detection. ENVIRONMENTAL HEALTH PERSPECTIVES 1995; 103 Suppl 1:21-3. [PMID: 7621792 PMCID: PMC1519334 DOI: 10.1289/ehp.95103s121] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
The analysis of environmental and biological samples often requires detection at the parts per billion (ppb) level. Plasma source mass spectrometry has potential as a method for the analysis and speciation of trace elements. This is due to the technique's highly selective nature and excellent sensitivity. In comparison to atomic emission detection, detection limits are usually two to three orders of magnitude lower for plasma MS determinations. Interfacing HPLC with plasma MS provides a means of separation that is necessary for speciation. Speciation involves the determination and quantitation of the various chemical forms of a particular element. A host of HPLC-ICP-MS techniques may be used to obtain this information. This brief report will focus on the most recent work in this area, with emphasis on the work done in our laboratory.
Collapse
|
197
|
Kumar U, Dorsey JG, Caruso JA, Evans EH. Metalloporphyrin speciation by liquid chromatography and inductively coupled plasma-mass spectrometry. J Chromatogr Sci 1994; 32:282-5. [PMID: 8063886 DOI: 10.1093/chromsci/32.7.282] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Inductively coupled plasma-mass spectrometry is investigated for the detection of metalloporphyrins (cobalt protoporphyrin, hemin, and zinc protoporphyrin) separated by liquid chromatography. A Hypersil SAS C1 column with mobile phase containing 68% methanol at a pH of 4.5 is used. The detection limits obtained are in the nanogram range for cobalt and zinc protoporphyrins, whereas for hemin, detection limits are in the microgram range. The accuracy of the method is evaluated by determining zinc protoporphyrin from the whole blood of a lead-poisoned patient.
Collapse
|
198
|
Carey JM, Vela NP, Caruso JA. Chromium determination by supercritical fluid chromatography with inductively coupled plasma mass spectrometric and flame ionization detection. J Chromatogr A 1994; 662:329-40. [PMID: 8143029 DOI: 10.1016/0021-9673(94)80520-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Supercritical fluid chromatography (SFC) has been investigated for the separation of a pair of beta-ketonate chromium compounds and a thermally labile organochromium dimer. A limited comparison between flame ionization detection (FID) and inductively coupled plasma mass spectrometric (ICP-MS) detection of these compounds is presented. The beta-ketonate complexes were observed with both detectors, while the thermally labile dimer was not observed with ICP-MS detection. Detection limits for these compounds with ICP-MS were in the range of 0.9 to 3 pg with FID giving values between 10 and 250 pg. Reproducibility of the method is between 1 and 4% relative standard deviation (R.S.D.). The technique provided a linear response over approximately three orders of magnitude. The effect of two mobile phases (nitrous oxide and carbon dioxide) on the detection by each of the detectors are presented in a qualitative manner. Finally, the SFC-ICP interface heating method and the manner in which the restrictor is heated in the FID system are compared and there effect on the chromatography discussed.
Collapse
|
199
|
Kumar UT, Vela NP, Dorsey JG, Caruso JA. Supercritical fluid extraction of organotins from biological samples and speciation by liquid chromatography and inductively coupled plasma mass spectrometry. J Chromatogr A 1993; 655:340-5. [PMID: 8111474 DOI: 10.1016/0021-9673(93)83242-k] [Citation(s) in RCA: 25] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Supercritical fluid extraction is used to extract tributyltin and triphenyltin from biological samples. The extraction conditions with carbon dioxide as supercritical fluid (methanol modifier used) are optimized for the organotins from fish tissue certified reference material. The total extraction time is found to be approximately 15 min. The recovery studies at the optimal conditions shows a recovery of 44% for tributyltin and 23% for triphenyltin. The reproducibilities for both the compounds extracted are within 2% R.S.D. The optimum conditions obtained are also used to extract tributyltin and triphenyltin from tuna fish obtained from a local grocery store.
Collapse
|
200
|
Pretty JR, Blubaugh EA, Caruso JA. Determination of arsenic(III) and selenium(IV) using an on-line anodic stripping voltammetry flow cell with detection by inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry. Anal Chem 1993; 65:3396-403. [PMID: 8297028 DOI: 10.1021/ac00071a011] [Citation(s) in RCA: 48] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
An on-line anodic stripping voltammetry (ASV) flow system, interfaced with inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICPMS) detectors, has been used for determination of arsenic(III) and selenium(IV) and for elimination of polyatomic interferences which arise from chloride in sample matrices. Details of the working electrode preparation are discussed. Arsenic signals in ICP-AES were enhanced by as much as 10 times through preconcentration of sample volumes up to 5 mL. Using ICP-AES detection, recoveries for analyte spikes in 1:10 diluted urine were 102% for As(III) (matrix-matched standards) and 91% for Se(IV) (standards in electrolyte). Using ICPMS detection, determination of certified Se(IV) and Se(IV) spikes in diluted NIST SRM 2670 elevated urine gave recoveries of 92-103%, while recoveries of As(III) spikes in diluted NIST SRM 2670 urine ranged from 94 to 113%. High levels of chloride matrix exhibited little effect on the arsenic signal with ICP-AES or ICPMS detection. Elimination of the polyatomic interference ArCl+ in ICPMS was very efficient for diluted NIST SRM 2670 urine and for a synthetic matrix of 1000 micrograms/mL chloride.
Collapse
|