176
|
Accoto D, Schena E, Cidda M, Francomano M, Saccomandi P, Silvestri S. A micro opto-mechanical displacement sensor based on micro-diffraction gratings: design and characterization. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2013:4714-7. [PMID: 24110787 DOI: 10.1109/embc.2013.6610600] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
A micro opto-mechanical displacement sensor is here presented. It is constituted by a sensing element based on two overlapped micro-diffraction gratings (MDGs). They present a platinum layer (45 nm of thick) on a glass substrate, a period of 525 µm constituted by a width of 150 µm of platinum separated (71.4% duty cycle). The working principle is based on the modulation of light intensity induced by the relative displacement between the MDGs: when a laser light perpendicularly hits the MDGs, the intensity of the transmitted light is a periodic function of the relative displacement between the two MDGs. A fiber optic is used to transport the transmitted light to a photodetector in order to avoid concerns related to the alignment between the optical components. The sensor's output is the ratio between the light intensity measured by the photodetector during the displacement of the MDGs and largest light intensity values measured in the whole range of measurement, therefore, it is lower than 1. The proposed sensor allows to discriminate displacement lower than 10 µm, using a cost effective micro-fabrication process implemented by the technique of Lift-Off. It shows a good linear behaviour in two ranges covering about one half of the MDGs period. Within the linear ranges it shows high sensitivity (about 0.5%/µm) and good accuracy (lower than 4% in the whole range of calibration); furthermore, the results show that a design with a duty cycle of 50% overcomes the marked decrease of sensitivity in a range of measurement corresponding to a grating period.
Collapse
|
177
|
Shah KG, Tolosa VM, Tooker AC, Felix SH, Pannu SS. Improved chronic neural stimulation using high surface area platinum electrodes. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2013:1546-9. [PMID: 24109995 DOI: 10.1109/embc.2013.6609808] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
We report a novel nano-cluster platinum (NCPt) film that exhibits enhanced performance as an electrode material for neural stimulation applications. Nano-cluster films were deposited using a custom physical vapor deposition process and patterned on a flexible polyimide microelectrode array using semiconductor processing technology. Electrode performance was characterized in vitro using electrochemical impedance spectroscopy and compared with sputtered thinfilm platinum (TFPt) electrodes. We characterized electrode impedance, charge storage capacity, voltage transient properties, and relative surface area enhancement in vitro. Preliminary lifetime testing of the electrode reveals that the NCPt electrodes degrade more slowly than TFPt electrodes. The combination of material biocompatibility, electrochemical performance, and preliminary lifetime results point to a promising new electrode material for neural interface devices.
Collapse
|
178
|
Tan F, Saucedo NM, Ramnani P, Mulchandani A. Label-Free Electrical Immunosensor for Highly Sensitive and Specific Detection of Microcystin-LR in Water Samples. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2015; 49:9256-63. [PMID: 26120934 DOI: 10.1021/acs.est.5b01674] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Microcystin-LR (MCLR) is one of the most commonly detected and toxic cyclic heptapeptide cyanotoxins released by cyanobacterial blooms in surface waters, for which sensitive and specific detection methods are necessary to carry out its recognition and quantification. Here, we present a single-walled carbon nanotube (SWCNTs)-based label-free chemiresistive immunosensor for highly sensitive and specific detection of MCLR in different source waters. MCLR was initially immobilized on SWCNTs modified interdigitated electrode, followed by incubation with monoclonal anti-MCLR antibody. The competitive binding of MCLR in sample solutions induced departure of the antibody from the antibody-antigen complexes formed on SWCNTs, resulting in change in the conductivity between source and drain of the sensor. The displacement assay greatly improved the sensitivity of the sensor compared with direct immunoassay on the same device. The immunosensor exhibited a wide linear response to log value of MCLR concentration ranging from 1 to 1000 ng/L, with a detection limit of 0.6 ng/L. This method showed good reproducibility, stability and recovery. The proposed method provides a powerful tool for rapid and sensitive monitoring of MCLR in environmental samples.
Collapse
|
179
|
Bayram B. Radiation impedance study of a capacitive micromachined ultrasonic transducer by finite element analysis. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2015; 138:614-623. [PMID: 26328680 DOI: 10.1121/1.4923361] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
In this study, radiation impedance of a capacitive micromachined ultrasonic transducer composed of square-shaped membranes arranged in m × m configuration (m = 1 - 5) is investigated using finite element analysis (FEA) of a commercially available software package(ANSYS). Radiation impedance is calculated for immersed membranes operating in conventional and collapse modes. Individual membrane response within the multi-membrane configuration is analyzed, and excited modes and their effects on radiation impedance and the pressure spectra are reported. This FEA provides an accurate behavior of the acoustic coupling of a thin membrane in a multi-membrane configuration, and extends above the anti-resonance frequency. The first resonance frequency of the membrane is excited for m × m (m ≥ 3) configuration in conventional mode and for m × m (m ≥ 2) configuration in collapse mode. Therefore, this frequency is determined to be responsible for the adverse effects observed in radiation impedance and pressure spectrum. A membrane configuration, which is missing the central membrane from the full m × m configuration is proposed, and is investigated with the FEA. This study is beneficial for the design of precise transducers suited for biomedical applications.
Collapse
|
180
|
Tooker A, Madsen TE, Yorita A, Crowell A, Shah KG, Felix S, Mayberg HS, Pannu S, Rainnie DG, Tolosa V. Microfabricated polymer-based neural interface for electrical stimulation/recording, drug delivery, and chemical sensing--development. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2013:5159-62. [PMID: 24110897 DOI: 10.1109/embc.2013.6610710] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
We present here a microfabricated, multi-functional neural interface with the ability to selectively apply electrical and chemical stimuli, while simultaneously monitoring both electrical and chemical activity in the brain. Such a comprehensive approach is required to understand and treat neuropsychiatric disorders, such as major depressive disorder (MDD), and to understand the mechanisms underlying treatments, such as pharmaceutical therapies and deep brain stimulation (DBS). The polymer-based, multi-functional neural interface is capable of electrical stimulation and recording, targeted drug delivery, and electrochemical sensing. A variety of different electrode and fluidic channel arrangements are possible with this fabrication process. Preliminary testing has shown the suitability of these neural interfaces for in vivo electrical stimulation and recording, as well as in vitro chemical sensing. Testing of the in vitro drug delivery and combined in vivo functionalities this neural interface are currently underway.
Collapse
|
181
|
Schattling P, Dreier C, Städler B. Janus subcompartmentalized microreactors. SOFT MATTER 2015; 11:5327-35. [PMID: 26054328 DOI: 10.1039/c5sm01161b] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
We report on Janus subcompartmentalized assemblies with enzyme loaded liposomes entrapped within a polymer carrier capsule - Janus subcompartmentalized microreactors. The concept is based on the use of Pickering emulsions and the subsequent deposition of interacting liposomes and polymer layers. We demonstrate the adjustment of the size of the Janus domains and the control over the amount of trapped liposomes using multiple liposome deposition steps. The obtained Janus capsosomes feature a distinct liposome domain within a closed polymeric hydrogel shell. The assembly of functional Janus microreactors using trypsin as cargo within the liposomal subcompartments is shown by performing locally confined enzymatic encapsulated catalysis. The presented assemblies with spatial control over the position of their liposomal subunits are a fascinating first step towards artificial cells with polarity.
Collapse
|
182
|
Kanno S, Lee S, Harashima T, Kuki T, Kino H, Mushiake H, Yao H, Tanaka T. Multiple optical stimulation to neuron using Si opto-neural probe with multiple optical waveguides and metal-cover for optogenetics. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2013:253-6. [PMID: 24109672 DOI: 10.1109/embc.2013.6609485] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
We have developed a Si opt-neural probe with multiple waveguides and metal cover for highly accurate optical stimulation. This neural probe had 16 recording sites, three optical waveguides, and metal cover for suppressing light leakage. We evaluated electrochemical properties of the recording sites, and confirmed that the neural probe had suitable characteristics for neural recording. We also demonstrated the optical stimulation to the neurons expressing ChR2 using our probe. As a result, we succeeded multisite optical stimulation, and observed that no light leakage from the optical waveguides because of the metal cover. From in vivo experiments, we successfully recorded optically modulated local field potential using the fabricated Si neural probe with optical waveguides. Moreover, we applied current source density analysis to the recorded LFPs. As a result, we confirmed that light induced membrane current sink in locally stimulated area. Our Si opto-neural probe with multiple optical waveguides and metal-cover is one of the most versatile tools for optogenetics.
Collapse
|
183
|
Li H, Munzar JD, Ng A, Juncker D. A versatile snap chip for high-density sub-nanoliter chip-to-chip reagent transfer. Sci Rep 2015; 5:11688. [PMID: 26148566 PMCID: PMC4493572 DOI: 10.1038/srep11688] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2015] [Accepted: 05/05/2015] [Indexed: 01/15/2023] Open
Abstract
The coordinated delivery of minute amounts of different reagents is important for microfluidics and microarrays, but is dependent on advanced equipment such as microarrayers. Previously, we developed the snap chip for the direct transfer of reagents, thus realizing fluidic operations by only manipulating microscope slides. However, owing to the misalignment between arrays spotted on different slides, millimeter spacing was needed between spots and the array density was limited. In this work, we have developed a novel double transfer method and have transferred 625 spots cm(-2), corresponding to >10000 spots for a standard microscope slide. A user-friendly snapping system was manufactured to make liquid handling straightforward. Misalignment, which for direct transfer ranged from 150-250 μm, was reduced to <40 μm for double transfer. The snap chip was used to quantify 50 proteins in 16 samples simultaneously, yielding limits of detection in the pg/mL range for 35 proteins. The versatility of the snap chip is illustrated with a 4-plex homogenous enzyme inhibition assay analyzing 128 conditions with precise timing. The versatility and high density of the snap chip with double transfer allows for the development of high throughput reagent transfer protocols compatible with a variety of applications.
Collapse
|
184
|
Yang HK, Yoon KH. Current status of encapsulated islet transplantation. J Diabetes Complications 2015; 29:737-43. [PMID: 25881917 DOI: 10.1016/j.jdiacomp.2015.03.017] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2015] [Revised: 03/10/2015] [Accepted: 03/11/2015] [Indexed: 02/07/2023]
Abstract
Islet transplantation is a treatment modality for diabetes mellitus that can maintain insulin levels within a physiologically appropriate range. However, wider clinical application is limited by insufficient donor numbers and a need for lifelong immunosuppression. Despite various clinical and preclinical trials, there is no single standard immunosuppressive regimen that can suppress acute and chronic immune reactions with lower toxicity to grafted islets. One of the strategies for overcoming lifelong immunosuppression is the incorporation of encapsulation technology, which can provide a physical immune barrier by keeping out high molecular weight immune system components, while still allowing low molecular weight oxygen, insulin and nutrients to pass through. Encapsulated islet transplantation approaches that have been studied so far include macroencapsulation, microencapsulation, conformal coating and nanoencapsulation. Herein we will review the basic concepts of islet encapsulation technique, earlier works to recent progress related to clinical studies and corporate investigations on encapsulated islet transplantation.
Collapse
MESH Headings
- Animals
- Diabetes Mellitus, Type 1/immunology
- Diabetes Mellitus, Type 1/surgery
- Diabetes Mellitus, Type 1/therapy
- Diabetes Mellitus, Type 2/immunology
- Diabetes Mellitus, Type 2/surgery
- Diabetes Mellitus, Type 2/therapy
- Graft Enhancement, Immunologic/adverse effects
- Graft Enhancement, Immunologic/methods
- Graft Enhancement, Immunologic/trends
- Humans
- Injections, Intraperitoneal
- Islets of Langerhans Transplantation/adverse effects
- Islets of Langerhans Transplantation/immunology
- Islets of Langerhans Transplantation/methods
- Islets of Langerhans Transplantation/trends
- Microtechnology
- Nanotechnology/trends
- Pancreas, Artificial/adverse effects
- Pancreas, Artificial/trends
- Surface Properties
- Transplantation, Heterologous/adverse effects
- Transplantation, Heterologous/methods
- Transplantation, Heterologous/trends
- Transplantation, Heterotopic/adverse effects
- Transplantation, Heterotopic/methods
- Transplantation, Heterotopic/trends
Collapse
|
185
|
Park HS, Liu S, McDonald J, Thakor N, Yang IH. Neuromuscular junction in a microfluidic device. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2013:2833-5. [PMID: 24110317 DOI: 10.1109/embc.2013.6610130] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Malfunctions at the site of neuromuscular junction (NMJ) of post-injuries or diseases are major barriers to recovery of function. The ability to efficiently derive motor neurons (MN) from embryonic stem cells has indicated promise toward the development of new therapies in increasing functional outcomes post injury. Recent advances in micro-technologies have provided advanced culture platforms allowing compartmentalization of sub-cellular components of neurons. In this study, we combined these advances in science and technology to develop a compartmentalized in vitro NMJ model. The developed NMJ system is between mouse embryonic stem cell (mESC)-derived MNs and c2c12 myotubes cultured in a compartmentalized polydimethylsiloxane (PDMS) microfluidic device. While some functional in vitro NMJ systems have been reported, this system would further contribute to research in NMJ-related diseases by providing a system to study the site of action of NMJ aimed at improving promoting better functional recovery.
Collapse
|
186
|
Chen Y, Abrams ES, Boles TC, Pedersen JN, Flyvbjerg H, Austin RH, Sturm JC. Concentrating genomic length DNA in a microfabricated array. PHYSICAL REVIEW LETTERS 2015; 114:198303. [PMID: 26024203 DOI: 10.1103/physrevlett.114.198303] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2014] [Indexed: 05/19/2023]
Abstract
We demonstrate that a microfabricated bump array can concentrate genomic-length DNA molecules efficiently at continuous, high flow velocities, up to 40 μm/s, if the single-molecule DNA globule has a sufficiently large shear modulus. Increase in the shear modulus is accomplished by compacting the DNA molecules to minimal coil size using polyethylene glycol (PEG) derived depletion forces. We map out the sweet spot, where concentration occurs, as a function of PEG concentration and flow speed using a combination of theoretical analysis and experiment. Purification of DNA from enzymatic reactions for next-generation DNA-sequencing libraries will be an important application of this development.
Collapse
|
187
|
Chandler DL. The heart of the matter: from guided microtools to 3-D printing and precision genome editing, promising research could lead to new advances in pediatric cardiology. IEEE Pulse 2015; 6:12-6. [PMID: 25974909 DOI: 10.1109/mpul.2015.2409096] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The smooth, powerful muscles of a newborn baby?s heart are pulsing normally, squeezing in and letting go rhythmically as a 3-mm-wide catheter-like tube snakes its way through, entering via an artery and being guided slowly by a surgeon. When it reaches its target?a protruding knot of malformed muscle tissue within a ventricle that has been partly blocking the valve?the tip of the precisely controlled tube whirs into action, with tiny scissor-like rotating blades gently grinding up the excess tissue as those pieces are sucked back into the device, leaving no floating particles that could lead to a blockage elsewhere. The defect is fully removed, and the heart?s function is restored to normal, leaving the child with the prospect of a normal life. The whole minimally invasive process takes place inside a beating heart and would otherwise have required open-heart surgery, with the heart stopped for a cardiopulmonary bypass.
Collapse
|
188
|
Yamaner FY, Zhang X, Oralkan Ö. A three-mask process for fabricating vacuum-sealed capacitive micromachined ultrasonic transducers using anodic bonding. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2015; 62:972-982. [PMID: 25965687 DOI: 10.1109/tuffc.2014.006794] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
This paper introduces a simplified fabrication method for vacuum-sealed capacitive micromachined ultrasonic transducer (CMUT) arrays using anodic bonding. Anodic bonding provides the established advantages of wafer-bondingbased CMUT fabrication processes, including process simplicity, control over plate thickness and properties, high fill factor, and ability to implement large vibrating cells. In addition to these, compared with fusion bonding, anodic bonding can be performed at lower processing temperatures, i.e., 350°C as opposed to 1100°C; surface roughness requirement for anodic bonding is more than 10 times more relaxed, i.e., 5-nm rootmean- square (RMS) roughness as opposed to 0.5 nm for fusion bonding; anodic bonding can be performed on smaller contact area and hence improves the fill factor for CMUTs. Although anodic bonding has been previously used for CMUT fabrication, a CMUT with a vacuum cavity could not have been achieved, mainly because gas is trapped inside the cavities during anodic bonding. In the approach we present in this paper, the vacuum cavity is achieved by opening a channel in the plate structure to evacuate the trapped gas and subsequently sealing this channel by conformal silicon nitride deposition in the vacuum environment. The plate structure of the fabricated CMUT consists of the single-crystal silicon device layer of a silicon-on-insulator wafer and a thin silicon nitride insulation layer. The presented fabrication approach employs only three photolithographic steps and combines the advantages of anodic bonding with the advantages of a patterned metal bottom electrode on an insulating substrate, specifically low parasitic series resistance and low parasitic shunt capacitance. In this paper, the developed fabrication scheme is described in detail, including process recipes. The fabricated transducers are characterized using electrical input impedance measurements in air and hydrophone measurements in immersion. A representative design is used to demonstrate immersion operation in conventional, collapse-snapback, and collapse modes. In collapsemode operation, an output pressure of 1.67 MPa pp is shown at 7 MHz on the surface of the transducer for 60-Vpp, 3-cycle sinusoidal excitation at 30-V dc bias.
Collapse
|
189
|
Stanton MM, Trichet-Paredes C, Sánchez S. Applications of three-dimensional (3D) printing for microswimmers and bio-hybrid robotics. LAB ON A CHIP 2015; 15:1634-1637. [PMID: 25632887 DOI: 10.1039/c5lc90019k] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
This article will focus on recent reports that have applied three-dimensional (3D) printing for designing millimeter to micrometer architecture for robotic motility. The utilization of 3D printing has rapidly grown in applications for medical prosthetics and scaffolds for organs and tissue, but more recently has been implemented for designing mobile robotics. With an increase in the demand for devices to perform in fragile and confined biological environments, it is crucial to develop new miniaturized, biocompatible 3D systems. Fabrication of materials at different scales with different properties makes 3D printing an ideal system for creating frameworks for small-scale robotics. 3D printing has been applied for the design of externally powered, artificial microswimmers and studying their locomotive capabilities in different fluids. Printed materials have also been incorporated with motile cells for bio-hybrid robots capable of functioning by cell contraction and swimming. These 3D devices offer new methods of robotic motility for biomedical applications requiring miniature structures. Traditional 3D printing methods, where a structure is fabricated in an additive process from a digital design, and non-traditional 3D printing methods, such as lithography and molding, will be discussed.
Collapse
|
190
|
Sun T, Tsang WM, Park WT, Merugu S. Surface Characteristics, Biodegradability and Biocompatibility of Porous Silicon for Microfabricated Neural Electrode. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY 2015; 15:2821-2828. [PMID: 26353499 DOI: 10.1166/jnn.2015.9249] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Porous Si (PSi) used for microfabrication of a novel neural electrode was prepared on Si wafers by an anodization process. Surface morphology and porous structure of the PSi were characterized using scanning electron microscopy (SEM) and transmission electron microscopy (TEM). 3D inter-connected and nano sized pores were homogeneously formed across the surface. Wettability of the PSi was determined using a sessile drop method. Although Si-Hx functional groups on the PSi surface had negative effect on wettability, water contact angle of the PSi reduced to 34.5 ± 0.5° due to the enhanced surface roughness and the capillary force generated by nano sized pores. Moreover, in vitro biocompatibility of the PSi was assessed by seeding a breast cancer cell line (MCF-7). After 5 days of culture, cell morphology was observed using a fluorescence microscope. Although more than 99% of the cells under the microscope were living for both Si and PSi samples, morphology of the cells attached on their surfaces was different. MTT assay was also used to quantitatively evaluate in vitro biocompatibility, and revealed false positive results due to the spontaneous reduction of MTT on the PSi surface. Therefore, MTT assay was not suitable for in vitro quantitatively study of PSi.
Collapse
|
191
|
Lo MC, Wang S, Singh S, Damodaran VB, Kaplan HM, Kohn J, Shreiber DI, Zahn JD. Coating flexible probes with an ultra fast degrading polymer to aid in tissue insertion. Biomed Microdevices 2015; 17:34. [PMID: 25681971 PMCID: PMC4827618 DOI: 10.1007/s10544-015-9927-z] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We report a fabrication process for coating neural probes with an ultrafast degrading polymer to create consistent and reproducible devices for neural tissue insertion. The rigid polymer coating acts as a probe insertion aid, but resorbs within hours post-implantation. Despite the feasibility for short term neural recordings from currently available neural prosthetic devices, most of these devices suffer from long term gliosis, which isolates the probes from adjacent neurons, increasing the recording impedance and stimulation threshold. The size and stiffness of implanted probes have been identified as critical factors that lead to this long term gliosis. Smaller, more flexible probes that match the mechanical properties of brain tissue could allow better long term integration by limiting the mechanical disruption of the surrounding tissue during and after probe insertion, while being flexible enough to deform with the tissue during brain movement. However, these small flexible probes inherently lack the mechanical strength to penetrate the brain on their own. In this work, we have developed a micromolding method for coating a non-functional miniaturized SU-8 probe with an ultrafast degrading tyrosine-derived polycarbonate (E5005(2K)). Coated, non-functionalized probes of varying dimensions were reproducibly fabricated with high yields. The polymer erosion/degradation profiles of the probes were characterized in vitro. The probes were also mechanically characterized in ex vivo brain tissue models by measuring buckling and insertion forces during probe insertion. The results demonstrate the ability to produce polymer coated probes of consistent quality for future in vivo use, for example to study the effects of different design parameters that may affect tissue response during long term chronic intra-cortical microelectrode neural recordings.
Collapse
|
192
|
Feist P, Hummon AB. Proteomic challenges: sample preparation techniques for microgram-quantity protein analysis from biological samples. Int J Mol Sci 2015; 16:3537-63. [PMID: 25664860 PMCID: PMC4346912 DOI: 10.3390/ijms16023537] [Citation(s) in RCA: 179] [Impact Index Per Article: 19.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2014] [Accepted: 01/29/2015] [Indexed: 12/22/2022] Open
Abstract
Proteins regulate many cellular functions and analyzing the presence and abundance of proteins in biological samples are central focuses in proteomics. The discovery and validation of biomarkers, pathways, and drug targets for various diseases can be accomplished using mass spectrometry-based proteomics. However, with mass-limited samples like tumor biopsies, it can be challenging to obtain sufficient amounts of proteins to generate high-quality mass spectrometric data. Techniques developed for macroscale quantities recover sufficient amounts of protein from milligram quantities of starting material, but sample losses become crippling with these techniques when only microgram amounts of material are available. To combat this challenge, proteomicists have developed micro-scale techniques that are compatible with decreased sample size (100 μg or lower) and still enable excellent proteome coverage. Extraction, contaminant removal, protein quantitation, and sample handling techniques for the microgram protein range are reviewed here, with an emphasis on liquid chromatography and bottom-up mass spectrometry-compatible techniques. Also, a range of biological specimens, including mammalian tissues and model cell culture systems, are discussed.
Collapse
|
193
|
Tolstosheeva E, Gordillo-González V, Biefeld V, Kempen L, Mandon S, Kreiter AK, Lang W. A multi-channel, flex-rigid ECoG microelectrode array for visual cortical interfacing. SENSORS 2015; 15:832-54. [PMID: 25569757 PMCID: PMC4327052 DOI: 10.3390/s150100832] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/21/2014] [Accepted: 12/18/2014] [Indexed: 11/16/2022]
Abstract
High-density electrocortical (ECoG) microelectrode arrays are promising signal-acquisition platforms for brain-computer interfaces envisioned, e.g., as high-performance communication solutions for paralyzed persons. We propose a multi-channel microelectrode array capable of recording ECoG field potentials with high spatial resolution. The proposed array is of a 150 mm2 total recording area; it has 124 circular electrodes (100, 300 and 500 µm in diameter) situated on the edges of concentric hexagons (min. 0.8 mm interdistance) and a skull-facing reference electrode (2.5 mm2 surface area). The array is processed as a free-standing device to enable monolithic integration of a rigid interposer, designed for soldering of fine-pitch SMD-connectors on a minimal assembly area. Electrochemical characterization revealed distinct impedance spectral bands for the 100, 300 and 500 µm-type electrodes, and for the array's own reference. Epidural recordings from the primary visual cortex (V1) of an awake Rhesus macaque showed natural electrophysiological signals and clear responses to standard visual stimulation. The ECoG electrodes of larger surface area recorded signals with greater spectral power in the gamma band, while the skull-facing reference electrode provided higher average gamma power spectral density (γPSD) than the common average referencing technique.
Collapse
|
194
|
Abstract
The sparse cells that are shed from tumors into peripheral circulation are an increasingly promising resource for noninvasive monitoring of cancer progression, early diagnosis of disease, and serve as a tool for improving our understanding of cancer metastasis. However, the extremely sparse concentration of circulating tumor cells (CTCs) in blood (~1-100 CTC in 7.5 mL of blood) as well as their heterogeneous biomarker expression has limited their detection using conventional laboratory techniques. To overcome these challenges, we have developed a microfluidic chip-based micro-Hall detector (μHD), which can directly measure single, immunomagnetically tagged cells in whole blood. The μHD can detect individual cells even in the presence of vast numbers of blood cells and unbound reactants, and does not require any washing or purification steps. Furthermore, this cost-effective, single-cell analytical technique is well suited for miniaturization into a mobile platform for low-cost point-of-care use. In this chapter, we describe the methodology used to design, fabricate, and apply these chips to cancer diagnostics.
Collapse
|
195
|
Abstract
We describe here a compact smartphone-based fluorescence detector for mHealth. A key element to achieving high sensitivity using low sensitivity phone cameras is a capillary array, which increases sensitivity by 100×. The capillary array was combined with a white LED illumination system to enable wide spectra fluorescent excitation in the range of 450-740 nm. The detector utilizes an orthographic projection system to form parallel light projection images from the capillaries at a close distance via an object-space telecentric lens configuration that reduces the total lens-to-object distance while maintaining uniformity in measurement between capillaries. To further increase the limit of detection (LOD), a computational image processing approach was employed to decrease the level of noise. This enables an additional 5-10× decrease in LOD. This smartphone-based detector was used to measure serial dilutions of fluorescein with a LOD of 1 nM with image stacking and 10 nM without image stacking, similar to the LOD obtained with a commercial plate reader. Moreover, the capillary array required a sample volume of less than 10 μl, which is an order of magnitude less than the 100 μl required for the plate reader.As fluorescence detection is widely used in sensitive biomedical assays, the approach described here has the potential to increase mHealth clinical utility, especially for telemedicine and for resource-poor settings in global health applications.
Collapse
|
196
|
Arai M, Kudo Y, Miki N. Electroencephalogram measurement from the hairy part of the scalp using polymer-based dry microneedle electrodes. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2015:3165-3168. [PMID: 26736964 DOI: 10.7567/jjap.54.06fp14] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
This paper reports a successful electroencephalogram (EEG) measurement from the hairy part of the scalp using a polymer-based dry microneedle electrode. The electrode consists of 25 pillars, each of which has a sharp microneedle on the top. Hairs are collected into the gaps of the pillars and the microneedles can reach the scalp surface. Since the microneedles can penetrate through the stratum corneum, no conductive gel is necessary to acquire high quality EEG. We experimentally investigated the pillar diameters in EEG measurement from the occipital region with hairs. The fabricated electrodes successfully measured EEG without any skin preparation or conductive gel.
Collapse
|
197
|
Chia HN, Wu BM. High-resolution direct 3D printed PLGA scaffolds: print and shrink. Biofabrication 2014. [PMID: 25514829 DOI: 10.1088/17585090/7/1/015002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/12/2023]
Abstract
Direct three-dimensional printing (3DP) produces the final part composed of the powder and binder used in fabrication. An advantage of direct 3DP is control over both the microarchitecture and macroarchitecture. Prints which use porogen incorporated in the powder result in high pore interconnectivity, uniform porosity, and defined pore size after leaching. The main limitations of direct 3DP for synthetic polymers are the use of organic solvents which can dissolve polymers used in most printheads and limited resolution due to unavoidable spreading of the binder droplet after contact with the powder. This study describes a materials processing strategy to eliminate the use of organic solvent during the printing process and to improve 3DP resolution by shrinking with a non-solvent plasticizer. Briefly, poly(lactic-co-glycolic acid) (PLGA) powder was prepared by emulsion solvent evaporation to form polymer microparticles. The printing powder was composed of polymer microparticles dry mixed with sucrose particles. After printing with a water-based liquid binder, the polymer microparticles were fused together to form a network by solvent vapor in an enclosed vessel. The sucrose is removed by leaching and the resulting scaffold is placed in a solution of methanol. The methanol acts as a non-solvent plasticizer and allows for polymer chain rearrangement and efficient packing of polymer chains. The resulting volumetric shrinkage is ∼80% at 90% methanol. A complex shape (honey-comb) was designed, printed, and shrunken to demonstrate isotropic shrinking with the ability to reach a final resolution of ∼400 μm. The effect of type of alcohol (i.e. methanol or ethanol), concentration of alcohol, and temperature on volumetric shrinking was studied. This study presents a novel materials processing strategy to overcome the main limitations of direct 3DP to produce high resolution PLGA scaffolds.
Collapse
|
198
|
Pashaie R, Anikeeva P, Lee JH, Prakash R, Yizhar O, Prigge M, Chander D, Richner TJ, Williams J. Optogenetic brain interfaces. IEEE Rev Biomed Eng 2014; 7:3-30. [PMID: 24802525 DOI: 10.1109/rbme.2013.2294796] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The brain is a large network of interconnected neurons where each cell functions as a nonlinear processing element. Unraveling the mysteries of information processing in the complex networks of the brain requires versatile neurostimulation and imaging techniques. Optogenetics is a new stimulation method which allows the activity of neurons to be modulated by light. For this purpose, the cell-types of interest are genetically targeted to produce light-sensitive proteins. Once these proteins are expressed, neural activity can be controlled by exposing the cells to light of appropriate wavelengths. Optogenetics provides a unique combination of features, including multimodal control over neural function and genetic targeting of specific cell-types. Together, these versatile features combine to a powerful experimental approach, suitable for the study of the circuitry of psychiatric and neurological disorders. The advent of optogenetics was followed by extensive research aimed to produce new lines of light-sensitive proteins and to develop new technologies: for example, to control the distribution of light inside the brain tissue or to combine optogenetics with other modalities including electrophysiology, electrocorticography, nonlinear microscopy, and functional magnetic resonance imaging. In this paper, the authors review some of the recent advances in the field of optogenetics and related technologies and provide their vision for the future of the field.
Collapse
|
199
|
Friess F, Nöchel U, Lendlein A, Wischke C. Polymer micronetworks with shape-memory as future platform to explore shape-dependent biological effects. Adv Healthc Mater 2014; 3:1986-90. [PMID: 25295760 DOI: 10.1002/adhm.201400433] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2014] [Revised: 09/09/2014] [Indexed: 01/23/2023]
Abstract
Polymer micronetworks allowing stimuli-induced, predefined, and spatially directed shape shifts. The temperature-induced on-demand switching of shape is introduced as a function of polyester carriers. With their adjustable -switching temperature, micronetworks may serve as a model system to explore static and dynamic shape effects in biological systems.
Collapse
|
200
|
Liu W, Liu X, Fangteng J, Wang S, Fang L, Shen H, Xiang S, Sun H, Yang B. Bioinspired polyethylene terephthalate nanocone arrays with underwater superoleophobicity and anti-bioadhesion properties. NANOSCALE 2014; 6:13845-13853. [PMID: 25303770 DOI: 10.1039/c4nr04471a] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
This paper presents a facile method to fabricate bioinspired polyethylene terephthalate (PET) nanocone arrays via colloidal lithography. The aspect ratio (AR) of the nanocones can be finely modulated ranging from 1 to 6 by regulating the etching time. The samples with the AR value of 6 can present underwater superoleophobicity with the underwater oil contact angle (OCA) of 171.8°. The as-prepared PET nanocone arrays perform anti-bioadhesion behavior, which inhibits the formation of the actin cytoskeleton when it used as the substrate for cell culture. Moreover, the oil wettability is temperature controlled after modifying the PET nanocone arrays with PNIPAAm film, and the oil wettability of the functionalized nanocone arrays can be transformed from the superoleophobic state with OCA about 151° to the oleophilic state with OCA about 25° reversibly. Due to the high-throughput, parallel fabrication and cost-efficiency of this method, it will be favourable for researchers to introduce oleophobic properties to various substrate and device surfaces. Due to the superoleophobicity and simple functionalizing properties, the PET nanocone arrays are very promising surfaces for anti-adhesion, self-cleaning and have potential applications in material, medical, and biological fields.
Collapse
|