1
|
Wu G, Chen J, Dou J, He X, Li HF, Lin JM. An electrochemiluminescence microsensor based on DNA-silver nanoclusters amplification for detecting cellular adenosine triphosphate. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2019-2024. [PMID: 38516852 DOI: 10.1039/d4ay00212a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/23/2024]
Abstract
Adenosine triphosphate (ATP), as the primary energy source, plays vital roles in many cellular events. Developing an efficient assay is crucial to rapidly evaluate the level of cellular ATP. A portable and integrated electrochemiluminescence (ECL) microsensor array based on a closed bipolar electrode (BPE) was presented. In the BPE unit, the ECL chemicals and oxidation/reduction were separated from the sensing chamber. The ATP aptamer was assembled with single-stranded DNA (ssDNA) in the sensing chamber. ATP capture made the aptamer disassemble from the ssDNA and facilitated DNA-templated silver nanocluster (Ag NC) generation by the target-rolling circle amplification (RCA) reaction. The guanine-rich padlock sequence produced tandem periodic cytosine-rich sequences by the RCA, inducing Ag NC generation in the cytosine-rich region of the produced DNA strands through Ag+ reduction. The in situ Ag NC generation enhanced the circuit conductivity of the BPE and promoted the ECL reaction of [Ru(bpy)2dppz]2+/tripropylamine in the anodic reservoir. On this ECL microsensor, a good linear relationship of ATP was achieved ranging from 30 to 1000 nM. The ATP content in HepG2 cells was selectively and sensitively determined without complex pretreatment. The ATP amount of 25 cells could be successfully detected when a sub-microliter sample was loaded.
Collapse
Affiliation(s)
- GuanQi Wu
- College of Biological Science and Technology, Beijing Forestry University, Beijing 100083, China.
- Department of Chemistry, Tsinghua University, Beijing, 100084, China.
| | - Jian Chen
- College of Biological Science and Technology, Beijing Forestry University, Beijing 100083, China.
- Department of Chemistry, Tsinghua University, Beijing, 100084, China.
| | - JinXin Dou
- Department of Chemistry, Tsinghua University, Beijing, 100084, China.
| | - XiangWei He
- College of Biological Science and Technology, Beijing Forestry University, Beijing 100083, China.
| | - Hai-Fang Li
- Department of Chemistry, Tsinghua University, Beijing, 100084, China.
| | - Jin-Ming Lin
- Department of Chemistry, Tsinghua University, Beijing, 100084, China.
| |
Collapse
|
2
|
Mwanza C, Ding SN. Newly Developed Electrochemiluminescence Based on Bipolar Electrochemistry for Multiplex Biosensing Applications: A Consolidated Review. BIOSENSORS 2023; 13:666. [PMID: 37367031 PMCID: PMC10295983 DOI: 10.3390/bios13060666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 06/16/2023] [Accepted: 06/16/2023] [Indexed: 06/28/2023]
Abstract
Recently, there has been an upsurge in the extent to which electrochemiluminescence (ECL) working in synergy with bipolar electrochemistry (BPE) is being applied in simple biosensing devices, especially in a clinical setup. The key objective of this particular write-up is to present a consolidated review of ECL-BPE, providing a three-dimensional perspective incorporating its strengths, weaknesses, limitations, and potential applications as a biosensing technique. The review encapsulates critical insights into the latest and novel developments in the field of ECL-BPE, including innovative electrode designs and newly developed, novel luminophores and co-reactants employed in ECL-BPE systems, along with challenges, such as optimization of the interelectrode distance, electrode miniaturization and electrode surface modification for enhancing sensitivity and selectivity. Moreover, this consolidated review will provide an overview of the latest, novel applications and advances made in this field with a bias toward multiplex biosensing based on the past five years of research. The studies reviewed herein, indicate that the technology is rapidly advancing at an outstanding purse and has an immense potential to revolutionize the general field of biosensing. This perspective aims to stimulate innovative ideas and inspire researchers alike to incorporate some elements of ECL-BPE into their studies, thereby steering this field into previously unexplored domains that may lead to unexpected, interesting discoveries. For instance, the application of ECL-BPE in other challenging and complex sample matrices such as hair for bioanalytical purposes is currently an unexplored area. Of great significance, a substantial fraction of the content in this review article is based on content from research articles published between the years 2018 and 2023.
Collapse
Affiliation(s)
- Christopher Mwanza
- Jiangsu Province Hi-Tech Key Laboratory for Bio-medical Research, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
- Chemistry Department, University of Zambia, Lusaka 10101, Zambia
| | - Shou-Nian Ding
- Jiangsu Province Hi-Tech Key Laboratory for Bio-medical Research, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| |
Collapse
|
3
|
Wang Y, Cao J, Liu Y. Bipolar Electrochemistry - A Powerful Tool for Micro/Nano-Electrochemistry. ChemistryOpen 2022; 11:e202200163. [PMID: 36229230 PMCID: PMC9716041 DOI: 10.1002/open.202200163] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 09/10/2022] [Indexed: 01/31/2023] Open
Abstract
The understanding of areas for "classical" electrochemistry (including catalysis, electrolysis and sensing) and bio-electrochemistry at the micro/nanoscale are focus on the continued performance facilitations or the exploration of new features. In the recent 20 years, a different mode for driving electrochemistry has been proposed, which is called as bipolar electrochemistry (BPE). BPE has garnered attention owing to the interesting properties: (i) its wireless nature facilitates electrochemical sensing and high throughput analysis; (ii) the gradient potential distribution on the electrodes surface is a useful tool for preparing gradient surfaces and materials. These permit BPE to be used for modification and analytical applications on a micro/nanoscale surface. This review aims to introduce the principle and classification of BPE and BPE at micro/nanoscale; sort out its applications in electrocatalysis, electrosynthesis, electrophoresis, power supply and so on; explain the confined BPE and summarize its analytical application for single entities (single cells, single particles and single molecules), and discuss finally the important direction of micro/nanoscale BPE.
Collapse
Affiliation(s)
- Yu‐Ling Wang
- College of Chemistry and Chemical EngineeringXinyang key laboratory of functional nanomaterials for bioanalysisXinyang Normal University464000XinyangP. R. China
| | - Jun‐Tao Cao
- College of Chemistry and Chemical EngineeringXinyang key laboratory of functional nanomaterials for bioanalysisXinyang Normal University464000XinyangP. R. China
| | - Yan‐Ming Liu
- College of Chemistry and Chemical EngineeringXinyang key laboratory of functional nanomaterials for bioanalysisXinyang Normal University464000XinyangP. R. China
| |
Collapse
|
4
|
Liang Y, Lai W, Su Y, Zhang C. A novel cloth-based multiway closed bipolar electrochemiluminescence biosensor for accurate detection of uric acid. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
5
|
Shared-cathode closed bipolar electrochemiluminescence cloth-based chip for multiplex detection. Anal Chim Acta 2022; 1206:339446. [PMID: 35473861 DOI: 10.1016/j.aca.2022.339446] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Revised: 12/31/2021] [Accepted: 01/03/2022] [Indexed: 11/23/2022]
Abstract
Electrochemiluminescence (ECL) chips have been widely used in the field of medical diagnosis. However, most of these chips currently in use are costly and require high amounts of sample. In this work, we present, for the first time, a shared-cathode closed bipolar electrochemiluminescence (SC-CBP-ECL) cloth-based chip, which can be used for multiplex detection. The SC-CBP-ECL chips ($0.03-0.05 for each chip) are manufactured using carbon ink- and wax-based screen-printing techniques, without the need for expensive and complex fabrication equipment. Under optimised conditions, the SC-CBP-ECL chips were successfully used for coinstantaneous detection of glucose in double ECL systems (i.e., Ru(bpy)32+ and luminol), with corresponding linear ranges of 0.05-1 mM and 0.05-10 mM, and detection limits of 0.0382 mM and 0.0422 mM. To our knowledge, this is the first report on the application of fibre material-based closed bipolar electrodes (C-BPE) combined with double ECL systems. Furthermore, the SC-CBP-ECL chips exhibit an acceptable specificity and good reproducibility and stability and can be used for glucose detection in human serum samples with a good agreement compared with the clinical method. Finally, the SC-CBP-ECL chips could be successfully used for simultaneous detection of seven glucose samples and also show potential for simultaneous detection of three different targets (hydrogen peroxide [H2O2], glucose, and uric acid [UA]). Therefore, we believe that the chip described in this study has broad potential application in the field of cost-effective multiplex detection.
Collapse
|
6
|
Salinas G, Arnaboldi S, Bouffier L, Kuhn A. Recent Advances in Bipolar Electrochemistry with Conducting Polymers. ChemElectroChem 2022. [DOI: 10.1002/celc.202101234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Gerardo Salinas
- Univ. Bordeaux ISM UMR 5255 CNRS, Bordeaux INP 33607 Pessac France
| | - Serena Arnaboldi
- Dip. Di Chimica Univ. degli Studi di Milano Via Golgi 19 20133 Milano Italy
| | - Laurent Bouffier
- Univ. Bordeaux ISM UMR 5255 CNRS, Bordeaux INP 33607 Pessac France
| | - Alexander Kuhn
- Univ. Bordeaux ISM UMR 5255 CNRS, Bordeaux INP 33607 Pessac France
| |
Collapse
|
7
|
Xiao Y, Wang G, Yi H, Chen S, Wu Q, Zhang S, Deng K, Zhang S, Shi ZQ, Yang X. Electrogenerated chemiluminescence of a Ru(bpy)32+/arginine system: a specific and sensitive detection of acetaminophen. RSC Adv 2022; 12:3157-3164. [PMID: 35425325 PMCID: PMC8979285 DOI: 10.1039/d1ra09371a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2021] [Accepted: 01/14/2022] [Indexed: 12/21/2022] Open
Abstract
Ru(bpy)3Cl2/TPrA is a prominent and widely used ECL system in analytical science. However, the co-reactant TPrA restricts the variety of applications because of its toxicity, volatility, and high cost. Here, we use arginine (Arg) as an alternative co-reactant for Ru(bpy)32+ by taking advantage of its low cost, non-toxicity, and biocompatibility. The mechanism of the Ru(bpy)32+/Arg system is that the deprotonated Arg can react with Ru(bpy)32+ to release emission. The similarity between the Ru(bpy)32+/Arg, Ru(bpy)32+/TPrA, and Ru(bpy)32+/DBAE systems demonstrates that Arg can be used as an alternative co-reactant for Ru(bpy)32+ ECL. As a proof of concept, we achieve an excellent performance for acetaminophen (Ace) detection based on the specificity of Arg and Ace, with excellent linearity, low detection limits, and good recoveries. This work is promising to expand the scope of the Ru(bpy)32+/Arg system and move forward their applications in bioassays. We use arginine as an alternative co-reactant for Ru(bpy)32+ by taking advantage of its low cost, non-toxicity, and biocompatibility. It is promising to expand the scope of the Ru(bpy)32+/Arg system and move forward their applications in bioassays.![]()
Collapse
Affiliation(s)
- Yi Xiao
- Key Laboratory of Study and Discovery of Small Targeted Molecules of Hunan Province, Department of Pharmacy, School of Medicine, Hunan Normal University, Changsha 410013, Hunan, China
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA
| | - Guofang Wang
- Key Laboratory of Study and Discovery of Small Targeted Molecules of Hunan Province, Department of Pharmacy, School of Medicine, Hunan Normal University, Changsha 410013, Hunan, China
| | - Haomin Yi
- Key Laboratory of Study and Discovery of Small Targeted Molecules of Hunan Province, Department of Pharmacy, School of Medicine, Hunan Normal University, Changsha 410013, Hunan, China
| | - Suhua Chen
- Hunan Provincial Maternal and Child Health Care Hospital, Changsha 410008, Hunan, China
| | - Qinyu Wu
- Key Laboratory of Study and Discovery of Small Targeted Molecules of Hunan Province, Department of Pharmacy, School of Medicine, Hunan Normal University, Changsha 410013, Hunan, China
| | - Siyi Zhang
- Key Laboratory of Study and Discovery of Small Targeted Molecules of Hunan Province, Department of Pharmacy, School of Medicine, Hunan Normal University, Changsha 410013, Hunan, China
| | - Kexin Deng
- Key Laboratory of Study and Discovery of Small Targeted Molecules of Hunan Province, Department of Pharmacy, School of Medicine, Hunan Normal University, Changsha 410013, Hunan, China
| | - Simeng Zhang
- Key Laboratory of Study and Discovery of Small Targeted Molecules of Hunan Province, Department of Pharmacy, School of Medicine, Hunan Normal University, Changsha 410013, Hunan, China
| | - Zi-Qi Shi
- Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing 210028, Jiangsu, China
| | - Xiaoping Yang
- Key Laboratory of Study and Discovery of Small Targeted Molecules of Hunan Province, Department of Pharmacy, School of Medicine, Hunan Normal University, Changsha 410013, Hunan, China
| |
Collapse
|
8
|
Arnaboldi S, Salinas G, Bonetti G, Cirilli R, Benincori T, Kuhn A. Bipolar Electrochemical Measurement of Enantiomeric Excess with Inherently Chiral Polymer Actuators. ACS MEASUREMENT SCIENCE AU 2021; 1:110-116. [PMID: 34939074 PMCID: PMC8679086 DOI: 10.1021/acsmeasuresciau.1c00011] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Indexed: 05/11/2023]
Abstract
Straightforward enantioselective analytical methods are very important for drug safety, considering that in certain cases one of the two enantiomers of a chiral molecule might be harmful for humans. In this work, we propose a simple system for the direct and easy read-out of the enantiomeric excess of 3,4-dihydroxyphenylalanine (DOPA) as a model analyte. A conducting oligomer, i.e. oligo-(3,3'-dibenzothiophene), bearing inherently chiral features, is electrogenerated on a polypyrrole film. The resulting freestanding hybrid material is used as a wireless enantioselective actuator in a bipolar electrochemical cell. Combining in a single setup two individual actuators with opposite chiral features allows a direct visual read-out of enantiomeric excess, as the bending amplitude of each of the two actuators is directly correlated with the concentration of the corresponding stereoisomer of the analyte. Optimization of the experimental parameters results in efficient bending, giving access to the percentage values of the enantiomeric excess in mixtures containing different ratios of the antipodes, thus opening the way to potential applications for chiral in situ analysis.
Collapse
Affiliation(s)
- Serena Arnaboldi
- Université
de Bordeaux, CNRS UMR 5255, Bordeaux INP,
ENSCBP, 16 avenue Pey
Berland, 33607 Pessac, France
- Dipartimento
di Chimica, Universita degli Studi di Milano, Via Golgi 19, 20133 Milano, Italy
| | - Gerardo Salinas
- Université
de Bordeaux, CNRS UMR 5255, Bordeaux INP,
ENSCBP, 16 avenue Pey
Berland, 33607 Pessac, France
| | - Giorgia Bonetti
- Dipartimento
di Scienza e Alta Tecnologia, Universita
degli Studi dell’Insubria, Via Valleggio 11, 22100 Como, Italy
| | - Roberto Cirilli
- Centro
Nazionale per il Controllo e la Valutazione dei Farmaci, Istituto Superiore di Sanità, Viale Regina Elena 299, 00161 Roma, Italy
| | - Tiziana Benincori
- Dipartimento
di Scienza e Alta Tecnologia, Universita
degli Studi dell’Insubria, Via Valleggio 11, 22100 Como, Italy
| | - Alexander Kuhn
- Université
de Bordeaux, CNRS UMR 5255, Bordeaux INP,
ENSCBP, 16 avenue Pey
Berland, 33607 Pessac, France
| |
Collapse
|
9
|
Che ZY, Wang XY, Ma X, Ding SN. Bipolar electrochemiluminescence sensors: From signal amplification strategies to sensing formats. Coord Chem Rev 2021. [DOI: 10.1016/j.ccr.2021.214116] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
10
|
Lian J, Wu J, Wu S, Yu W, Wang P, Liu L, Zuo Q. Investigation of viscous effects on droplet generation in a co-flowing step emulsification device. Colloids Surf A Physicochem Eng Asp 2021. [DOI: 10.1016/j.colsurfa.2021.127468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
11
|
Hao N, Qiu Y, Lu J, Han X, Li Y, Qian J, Wang K. Flexibly regulated electrochemiluminescence of all-inorganic perovskite CsPbBr3 quantum dots through electron bridge to across interfaces between polar and non-polar solvents. CHINESE CHEM LETT 2021. [DOI: 10.1016/j.cclet.2021.01.029] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
12
|
Ismail A, Voci S, Descamps L, Buhot A, Sojic N, Leroy L, Bouchet-Spinelli A. Bipolar Electrochemiluminescence Imaging: A Way to Investigate the Passivation of Silicon Surfaces. Chemphyschem 2021; 22:1094-1100. [PMID: 33826213 DOI: 10.1002/cphc.202100112] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Revised: 03/17/2021] [Indexed: 11/09/2022]
Abstract
This work depicts the original combination of electrochemiluminescence (ECL) and bipolar electrochemistry (BPE) to map in real-time the oxidation of silicon in microchannels. We fabricated model silicon-PDMS microfluidic chips, optionally containing a restriction, and monitored the evolution of the surface reactivity using ECL. BPE was used to remotely promote ECL at the silicon surface inside microfluidic channels. The effects of the fluidic design, the applied potential and the resistance of the channel (controlled by the fluidic configuration) on the silicon polarization and oxide formation were investigated. A potential difference down to 6 V was sufficient to induce ECL, which is two orders of magnitude less than in classical BPE configurations. Increasing the resistance of the channel led to an increase in the current passing through the silicon and boosted the intensity of ECL signals. Finally, the possibility of achieving electrochemical reactions at predetermined locations on the microfluidic chip was investigated using a patterning of the silicon oxide surface by etched micrometric squares. This ECL imaging approach opens exciting perspectives for the precise understanding and implementation of electrochemical functionalization on passivating materials. In addition, it may help the development and the design of fully integrated microfluidic biochips paving the way for development of original bioanalytical applications.
Collapse
Affiliation(s)
- Abdulghani Ismail
- IRIG-SYMMES, University Grenoble Alpes, CEA, CNRS, 17 Avenue des Martyrs, 38054, Grenoble, France
| | - Silvia Voci
- ISM, UMR CNRS 5255, University of Bordeaux, Bordeaux INP, 351 Cours de la Libération, 33405, Talence, France
| | - Lucie Descamps
- IRIG-SYMMES, University Grenoble Alpes, CEA, CNRS, 17 Avenue des Martyrs, 38054, Grenoble, France
| | - Arnaud Buhot
- IRIG-SYMMES, University Grenoble Alpes, CEA, CNRS, 17 Avenue des Martyrs, 38054, Grenoble, France
| | - Neso Sojic
- ISM, UMR CNRS 5255, University of Bordeaux, Bordeaux INP, 351 Cours de la Libération, 33405, Talence, France
| | - Loïc Leroy
- IRIG-SYMMES, University Grenoble Alpes, CEA, CNRS, 17 Avenue des Martyrs, 38054, Grenoble, France
| | - Aurélie Bouchet-Spinelli
- IRIG-SYMMES, University Grenoble Alpes, CEA, CNRS, 17 Avenue des Martyrs, 38054, Grenoble, France
| |
Collapse
|
13
|
Xiao Y, Chen S, Zhang S, Wang G, Yi H, Xin GZ, Yang X. Mesoporous silica-mediated controllable electrochemiluminescence quenching for immunosensor with simplicity, sensitivity and tunable detection range. Talanta 2021; 231:122399. [PMID: 33965049 DOI: 10.1016/j.talanta.2021.122399] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2021] [Revised: 03/30/2021] [Accepted: 04/03/2021] [Indexed: 01/08/2023]
Abstract
Straightforward and accurate measurement of medical biomarkers is of essential importance in clinical diagnostics and treatments. However, the major challenge is the diversity in dynamic range of different biomarkers ranging from pg mL-1 to μg mL-1 in various body fluids and tissues among patients. Here, we develop a mesoporous silica (MS)-mediated controllable electrochemiluminescence (ECL) quenching of immunosensor that allows accurate immunoassays with simplicity, sensitivity and tunable sensing range. MS is employed to enhance the sensitivity and tune ECL quenching to broaden the detection range just by altering luminophore (Ru(bpy)32+) and coreactant (DBAE) concentration without additional modifications. The immunoassay is followed: homogeneous sandwich immunoreaction, magnetic separation, and ECL quenching detection. As a proof-of-concept, simple and sensitive detection of IgG is achieved ranging from pg mL-1 to μg mL-1, and applications of the strategy are extended by the combination of ECL immunosensor with commercial ELISA kit. This study will not only be expected to serve as a new avenue for the assay of physiological and clinical implications of immunological biomarkers, but also benefit a wide range of applications that require a tunable detection range and ultrahigh sensitivity.
Collapse
Affiliation(s)
- Yi Xiao
- Key Laboratory of Study and Discovery of Small Targeted Molecules of Hunan Province, Department of Pharmacy, School of Medicine, Hunan Normal University, Changsha, 410013, Hunan, China; John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, 02138, USA
| | - Suhua Chen
- Hunan Provincial Maternal and Child Health Care Hospital, Changsha, 410008, Hunan, China
| | - Simeng Zhang
- Key Laboratory of Study and Discovery of Small Targeted Molecules of Hunan Province, Department of Pharmacy, School of Medicine, Hunan Normal University, Changsha, 410013, Hunan, China
| | - Guofang Wang
- Key Laboratory of Study and Discovery of Small Targeted Molecules of Hunan Province, Department of Pharmacy, School of Medicine, Hunan Normal University, Changsha, 410013, Hunan, China
| | - Haomin Yi
- Key Laboratory of Study and Discovery of Small Targeted Molecules of Hunan Province, Department of Pharmacy, School of Medicine, Hunan Normal University, Changsha, 410013, Hunan, China
| | - Gui-Zhong Xin
- State Key Laboratory of Natural Medicines, Department of Chinese Medicines Analysis, China Pharmaceutical University, Nanjing, 210009, China.
| | - Xiaoping Yang
- Key Laboratory of Study and Discovery of Small Targeted Molecules of Hunan Province, Department of Pharmacy, School of Medicine, Hunan Normal University, Changsha, 410013, Hunan, China.
| |
Collapse
|
14
|
Glasscott MW, Voci S, Kauffmann PJ, Chapoval AI, Dick JE. Mapping Solvent Entrapment in Multiphase Systems by Electrogenerated Chemiluminescence. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2021; 37:2907-2912. [PMID: 33625240 DOI: 10.1021/acs.langmuir.0c03445] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The interfacial properties of multiphase systems are often difficult to quantify. We describe the observation and quantification of immiscible solvent entrapment on a carbonaceous electrode surface using microscopy-coupled electrogenerated chemiluminescence (ECL). As aqueous microdroplets suspended in 1,2-dichloroethane collide with a glassy carbon electrode surface, small volumes of the solvent become entrapped between the electrode and aqueous phase, resulting in an overestimation of the true microdroplet/electrode contact area. To quantify the contribution of solvent entrapment decreasing the microdroplet contact area, we drive an ECL reaction within the microdroplet phase using tris(bipyridine)ruthenium(II) chloride ([Ru(bpy)3]Cl2) as the ECL luminophore and sodium oxalate (Na2C2O4) as the co-reactant. Importantly, the hydrophilicity of sodium oxalate ensures that the reaction proceeds in the aqueous phase, permitting a clear contrast between the aqueous and 1,2-dichloroethane present at the electrode interface. With the contrast provided by ECL imaging, we quantify the microdroplet radius, apparent microdroplet contact area (aqueous + entrapped 1,2-dichloroethane), entrapped solvent contact area, and the number of entrapped solvent pockets per droplet. These data permit the extraction of the true microdroplet/electrode contact area for a given droplet, as well as a statistical assessment regarding the probability of solvent entrapment based on microdroplet size.
Collapse
Affiliation(s)
- Matthew W Glasscott
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States
| | - Silvia Voci
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States
| | - Philip J Kauffmann
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States
| | - Andrei I Chapoval
- Russian-American Anti-Cancer Center, Altai State University, Barnaul 656049, Russia
| | - Jeffrey E Dick
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States
- Lineberger Comprehensive Cancer Center, School of Medicine, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States
| |
Collapse
|
15
|
Dai W, Zhao W, Ma Y, Ye J, Jin J. Development of Miniaturized Electrochemiluminescence Instrument using Multi‐pixel Photon Counter as the Optical Detector. ELECTROANAL 2020. [DOI: 10.1002/elan.202000094] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Wanlin Dai
- School of Chemistry and Chemical Engineering South China University of Technology Guangzhou 510641 P.R. China
| | - Wenyuan Zhao
- School of Chemistry and Chemical Engineering South China University of Technology Guangzhou 510641 P.R. China
| | - Ying Ma
- School of Chemistry and Chemical Engineering South China University of Technology Guangzhou 510641 P.R. China
| | - Jianshan Ye
- School of Chemistry and Chemical Engineering South China University of Technology Guangzhou 510641 P.R. China
| | - Jiye Jin
- Department of Chemistry Faculty of Science Shinshu University 3-1-1 Asahi Matsumoto Nagano 390-8621 Japan
| |
Collapse
|
16
|
Xu P, Jiang F, Zhang H, Yin R, Cen L, Zhang W. Calcium Carbonate/Gelatin Methacrylate Microspheres for 3D Cell Culture in Bone Tissue Engineering. Tissue Eng Part C Methods 2020; 26:418-432. [DOI: 10.1089/ten.tec.2020.0064] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Affiliation(s)
- Pengwei Xu
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai, China
| | - Fuliang Jiang
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai, China
| | - Hongbo Zhang
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai, China
| | - Ruixue Yin
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai, China
| | - Lian Cen
- School of Chemical Engineering, East China University of Science and Technology, Shanghai, China
| | - Wenjun Zhang
- School of Mechatronics and Automation, Shanghai University, Shanghai, China
- Division of Biomedical Engineering, University of Saskatchewan, Saskatoon, Canada
| |
Collapse
|
17
|
Abstract
Reactivity at phase boundaries is central to many areas of chemistry, from synthesis to heterogeneous catalysis. New tools are necessary to gain a more detailed understanding of processes occurring at these boundaries. We describe a series of experiments to visualize phase boundaries using electrogenerated chemiluminescence (ECL) on glassy carbon electrodes. By taking advantage of the solubilities of the ECL luminophore and the coreactant in different liquid phases, we demonstrate that the interface of various phases (i.e., the boundaries formed between a water microdroplet, 1,2-dichloroethane, and a glassy carbon electrode and the boundaries formed between an oxygen bubble, water, and a glassy carbon electrode) can be evaluated. We measured microdroplet contact radii, the three-phase boundary thickness, and growth dynamics of electrogenerated O2 bubbles. These experimental tools and the fundamental knowledge they yield will find applications in biology, nanoscience, synthesis, and energy storage and conversion, where understanding phase boundary chemistry is essential.
Collapse
Affiliation(s)
- Matthew W Glasscott
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States
| | - Jeffrey E Dick
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States
- Lineberger Comprehensive Cancer Center, School of Medicine, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States
| |
Collapse
|
18
|
Qin X, Yu J, Jiao M, Shan X, Xian X, Wang D, Tao N. Integrating Electrochemical and Colorimetric Sensors with a Webcam Readout for Multiple Gas Detection. Anal Chem 2020; 92:799-805. [PMID: 31762258 DOI: 10.1021/acs.analchem.9b03202] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Multisensor detectors have merits of low cost, compact size, and capability of supplying accurate and reliable information otherwise hard to obtain by any single sensors. They are therefore highly desired in various applications. Despite the advantages and needs, they face great challenges in technique especially when integrating sensors with different sensing principles. To bridge the gap between the demand and technique, we here demonstrated an integration of electrochemical and colorimetric sensors with a webcam readout for multiple gas detection. Designed with two parallel gas channels but independent sensor cells, the dual-sensor detector could simultaneously detect each gas from their gas mixture by analysis of the group photo of the two sensors. Using Ag electro-dissolution as reporter, the bipolar electrochemical sensor achieved quantitative analysis for the first time thanks to application of pulse voltage. The sacrificed Ag layer used in the bipolar electrochemical (EC) sensor was recycled from CD, which further decreased the sensor cost and supplied a new way of CD recycling. The EC O2 sensor response, edge displacement of Ag layer due to electrochemical dissolution, has a linear relationship with O2 concentration ranging from 0 to 30% and has good selectivity to common oxidative gases. The colorimetric NO2 sensor linearly responded to NO2 concentrations ranging from 0 to 230 ppb with low detection limit of 10 ppb, good selectivity, and humidity tolerance. This integration method could be extended to integrating other gas sensors.
Collapse
Affiliation(s)
- Xingcai Qin
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering , Nanjing University , Nanjing , Jiangsu 210023 , China
| | - Jingjing Yu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering , Nanjing University , Nanjing , Jiangsu 210023 , China
| | - Mengchi Jiao
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering , Nanjing University , Nanjing , Jiangsu 210023 , China
| | - Xiaonan Shan
- Biosensor and Bioelectronics Center, the Biodesign Institute , Arizona State University , Tempe , Arizona 85287 , United States
| | - Xiaojun Xian
- Biosensor and Bioelectronics Center, the Biodesign Institute , Arizona State University , Tempe , Arizona 85287 , United States
| | - Di Wang
- Biosensor and Bioelectronics Center, the Biodesign Institute , Arizona State University , Tempe , Arizona 85287 , United States
| | - Nongjian Tao
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering , Nanjing University , Nanjing , Jiangsu 210023 , China.,Biosensor and Bioelectronics Center, the Biodesign Institute , Arizona State University , Tempe , Arizona 85287 , United States
| |
Collapse
|
19
|
|
20
|
Xiong X, Li Y, Yuan W, Lu Y, Xiong X, Li Y, Chen X, Liu Y. Screen printed bipolar electrode for sensitive electrochemiluminescence detection of aflatoxin B1 in agricultural products. Biosens Bioelectron 2019; 150:111873. [PMID: 31748193 DOI: 10.1016/j.bios.2019.111873] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2019] [Revised: 11/10/2019] [Accepted: 11/11/2019] [Indexed: 12/20/2022]
Abstract
In order to avoid the occurrence of false positives and false negatives caused by improper pretreatment during the detection of aflatoxin B1 by enzyme linked immunosorbent assay (ELISA). In this paper, we developed a screen printed bipolar electrode (BPE) for sensitive electrochemiluminescence (ECL) detection of aflatoxin B1 in agricultural products. The sensor uses a cathode of closed BPE as a functional sensing interface and an anode as a signal collection interface. In this way, the analyte does not need to participate in the ECL reaction of the anode. It avoids direct contact of photoactive molecules with complex reaction systems and greatly broadens the range of applications for ECL. After mixing the test sample with a known fixed concentration of horseradish peroxidase-labeled AFB1 (HRP-AFB1), they compete for binding to monoclonal antibodies. HRP catalyzes the polymerization of aniline to form polyaniline (PANI). Thereby causing a change in the oxidation-reduction potential and the ECL intensity in the electrochemical system, and then achieve the purpose of detecting the AFB1 concentration in the sample. As a result, the sensor has a good analytical performance for AFB1 with a linear range of 0.1-100 ng mL-1 and a detection limit of 0.033 ng mL-1. The sensor avoids the direct contact between the reaction system and the signal measurement system. In recovery experiment for six grains, the results demonstrate that the recovery rate and accuracy of this sensor is better than that of ELISA. This method provides a new idea for the detection of other mycotoxins in grains.
Collapse
Affiliation(s)
- Xiaohui Xiong
- Coll Food Sci & Light Ind, Nanjing Tech University, Nanjing, 211816, China
| | - Yafei Li
- Coll Food Sci & Light Ind, Nanjing Tech University, Nanjing, 211816, China
| | - Wei Yuan
- Coll Food Sci & Light Ind, Nanjing Tech University, Nanjing, 211816, China
| | - Yichen Lu
- Coll Food Sci & Light Ind, Nanjing Tech University, Nanjing, 211816, China
| | - Xiong Xiong
- Coll Food Sci & Light Ind, Nanjing Tech University, Nanjing, 211816, China
| | - Yi Li
- Coll Food Sci & Light Ind, Nanjing Tech University, Nanjing, 211816, China
| | - Xiaoye Chen
- Coll Food Sci & Light Ind, Nanjing Tech University, Nanjing, 211816, China.
| | - Yuanjian Liu
- Coll Food Sci & Light Ind, Nanjing Tech University, Nanjing, 211816, China.
| |
Collapse
|
21
|
Hao N, Lu J, Dai Z, Qian J, Zhang J, Guo Y, Wang K. Analysis of aqueous systems using all-inorganic perovskite CsPbBr3 quantum dots with stable electrochemiluminescence performance using a closed bipolar electrode. Electrochem commun 2019. [DOI: 10.1016/j.elecom.2019.106559] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
|
22
|
Silver-based metal-organic gels as novel coreactant for enhancing electrochemiluminescence and its biosensing potential. Biosens Bioelectron 2019; 134:29-35. [DOI: 10.1016/j.bios.2019.03.058] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 03/07/2019] [Accepted: 03/26/2019] [Indexed: 01/06/2023]
|
23
|
Sanjuan-Alberte P, Saleh E, Shaw AJ, Lacalendola N, Willmott G, Vaithilingam J, Alexander MR, Hague RJM, Rawson FJ. Remotely Controlled in Situ Growth of Silver Microwires Forming Bioelectronic Interfaces. ACS APPLIED MATERIALS & INTERFACES 2019; 11:8928-8936. [PMID: 30735349 DOI: 10.1021/acsami.8b22075] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
There is a pressing need to advance our ability to construct three-dimensional (3D) functional bioelectronic interfaces. Additionally, to ease the transition to building cellular electronic systems, a remote approach to merge electrical components with biology is desirable. By combining 3D digital inkjet printing with bipolar electrochemistry, we remotely control and fabricate conductive wires, forming a first of its kind contactless bionic manufacturing procedure. It enables controlled fabrication of conductive wires in a three-dimensional configuration. Moreover, we demonstrate that this technology could be used to grow and interface conductive conduits in situ with mammalian cells, offering a new strategy to engineering bioelectronic interfaces. This represents a step change in the production of functional complex circuitry and considerably increases the manufacturing capabilities of merging cells with electronics. This approach provides a platform to construct bioelectronics in situ offering a potential paradigm shift in the methods for building bioelectronics with potential applications in biosensing and bioelectronic medicine.
Collapse
Affiliation(s)
| | | | | | - Nicola Lacalendola
- The MacDiarmid Institute for Advanced Materials and Technology, Department of Physics and Chemistry , The University of Auckland , Auckland 1010 , New Zealand
| | - Geoff Willmott
- The MacDiarmid Institute for Advanced Materials and Technology, Department of Physics and Chemistry , The University of Auckland , Auckland 1010 , New Zealand
| | | | | | | | | |
Collapse
|
24
|
Gamero-Quijano A, Molina-Osorio AF, Peljo P, Scanlon MD. Closed bipolar electrochemistry in a four-electrode configuration. Phys Chem Chem Phys 2019; 21:9627-9640. [DOI: 10.1039/c9cp00774a] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
The thermodynamic theory underpinning closed bipolar electrochemistry in a 4-electrode configuration is presented; a technique applicable to spectro-electroanalysis, energy storage, electrocatalysis and electrodeposition.
Collapse
Affiliation(s)
- Alonso Gamero-Quijano
- The Bernal Institute and Department of Chemical Sciences
- School of Natural Sciences
- University of Limerick (UL)
- Limerick V94 T9PX
- Ireland
| | - Andrés F. Molina-Osorio
- The Bernal Institute and Department of Chemical Sciences
- School of Natural Sciences
- University of Limerick (UL)
- Limerick V94 T9PX
- Ireland
| | - Pekka Peljo
- Research Group of Physical Electrochemistry and Electrochemical Physics
- Department of Chemistry and Materials Science
- Aalto University
- 00076 Aalto
- Finland
| | - Micheál D. Scanlon
- The Bernal Institute and Department of Chemical Sciences
- School of Natural Sciences
- University of Limerick (UL)
- Limerick V94 T9PX
- Ireland
| |
Collapse
|
25
|
Zhang JD, Lu L, Zhu XF, Zhang LJ, Yun S, Duanmu CS, He L. Direct Observation of Oxidation Reaction via Closed Bipolar Electrode-Anodic Electrochemiluminescence Protocol: Structural Property and Sensing Applications. ACS Sens 2018; 3:2351-2358. [PMID: 30350590 DOI: 10.1021/acssensors.8b00736] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
In this work, we developed an innovative closed bipolar electrode (BPE)-electrochemiluminescence (ECL) sensing strategy with generality for target detection. Based on charge balance and 100% current efficiency between the closed BPE poles and the driving electrodes, one of the driving electrodes in one cell of the closed BPE system was employed as ECL sensing surface to reflect the target on the BPE pole in the opposite cell. Compared with traditional BPE-ECL sensing method, which in general adopted the anodic ECL reagents such as Ru(bpy)32+ and its coreactant on one pole (anode) to reflect the target (occurring reduction reaction) on the other pole (cathode), the difference was that the targets occurring oxidation reaction could be detected by the anodic ECL reagents based on this strategy. To verify the feasibility of this strategy, the detection principle was stated first, and Fe(CN)64- as model target at anodic BPE pole were detected by anodic ECL reagents (Ru(bpy)32+ and TprA) on the driving electrode first. The ECL signals showed good performance for target detection. By changing the size and the material of the BPE pole where the targets were located, the detection of l-ascorbic acid (AA), uric acid (UA), and dopamine (DA) as other model targets with higher detection limit were accomplished. Visual and high-throughput detection of AA, UA, and DA were also successfully realized by an array of the closed BPE system. This closed BPE (array) system is an effective supplement of traditional BPE-ECL sensing and could greatly expand the scope of the detection target.
Collapse
Affiliation(s)
- Jia-Dong Zhang
- National & Local Joint Engineering Research Center for Deep Utilization Technology of Rock-salt Resource, School of Chemical Engineering, Huaiyin Institute of Technology, Huai’an, Jiangsu 223003, China
| | - Lei Lu
- National & Local Joint Engineering Research Center for Deep Utilization Technology of Rock-salt Resource, School of Chemical Engineering, Huaiyin Institute of Technology, Huai’an, Jiangsu 223003, China
| | - Xiu-Fang Zhu
- National & Local Joint Engineering Research Center for Deep Utilization Technology of Rock-salt Resource, School of Chemical Engineering, Huaiyin Institute of Technology, Huai’an, Jiangsu 223003, China
| | - Li-Jing Zhang
- National & Local Joint Engineering Research Center for Deep Utilization Technology of Rock-salt Resource, School of Chemical Engineering, Huaiyin Institute of Technology, Huai’an, Jiangsu 223003, China
| | - Shan Yun
- National & Local Joint Engineering Research Center for Deep Utilization Technology of Rock-salt Resource, School of Chemical Engineering, Huaiyin Institute of Technology, Huai’an, Jiangsu 223003, China
| | - Chuan-Song Duanmu
- National & Local Joint Engineering Research Center for Deep Utilization Technology of Rock-salt Resource, School of Chemical Engineering, Huaiyin Institute of Technology, Huai’an, Jiangsu 223003, China
| | - Lei He
- National & Local Joint Engineering Research Center for Deep Utilization Technology of Rock-salt Resource, School of Chemical Engineering, Huaiyin Institute of Technology, Huai’an, Jiangsu 223003, China
| |
Collapse
|
26
|
Zhang L, Gupta B, Goudeau B, Mano N, Kuhn A. Wireless Electromechanical Readout of Chemical Information. J Am Chem Soc 2018; 140:15501-15506. [PMID: 30347149 DOI: 10.1021/jacs.8b10072] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Collecting electrochemical information concerning the presence of molecules in a solution is usually achieved by measuring current, potential, resistance, or impedance via connection to a power supply. Here, we suggest wireless electromechanical actuation as a straightforward readout of chemical information. This can be achieved based on the concept of bipolar electrochemistry, which allows measuring the presence of different model species in a quantitative way. We validate the concept by using a free-standing polypyrrole film. Its positively polarized extremity participates in an oxidation of the analyte and delivers electrons to the opposite extremity for the reduction of the polymer. This reduction is accompanied by the insertion of counterions and thus leads to partial swelling of the film, inducing its bending. The resulting actuation is found to be a linear function of the analyte concentration, and also a Michaelis-Menten type correlation is obtained for biochemical analytes. This electromechanical transduction allows an easy optical readout and opens up very interesting perspectives not only in the field of sensing but also far beyond, such as for the elaboration of self-regulating biomimetic systems.
Collapse
Affiliation(s)
- Lin Zhang
- Université Bordeaux , CNRS UMR 5255, Bordeaux INP, ENSCBP, 16 Avenue Pey Berland , 33607 Pessac , France.,Centre de Recherche Paul Pascal , CNRS UMR 5031, Avenue Albert Schweitzer , 33600 Pessac , France
| | - Bhavana Gupta
- Université Bordeaux , CNRS UMR 5255, Bordeaux INP, ENSCBP, 16 Avenue Pey Berland , 33607 Pessac , France
| | - Bertrand Goudeau
- Université Bordeaux , CNRS UMR 5255, Bordeaux INP, ENSCBP, 16 Avenue Pey Berland , 33607 Pessac , France
| | - Nicolas Mano
- Centre de Recherche Paul Pascal , CNRS UMR 5031, Avenue Albert Schweitzer , 33600 Pessac , France
| | - Alexander Kuhn
- Université Bordeaux , CNRS UMR 5255, Bordeaux INP, ENSCBP, 16 Avenue Pey Berland , 33607 Pessac , France
| |
Collapse
|
27
|
Ji Z, Shu Y, Xu Q, Hu X. Ultrasensitive electrochemiluminescence determination of trace Ag ions based on the signal amplification caused by its catalytic effect on Mn(II) oxidation using graphite catheter as electrode. Talanta 2018; 187:188-192. [PMID: 29853033 DOI: 10.1016/j.talanta.2018.05.029] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2018] [Revised: 04/26/2018] [Accepted: 05/07/2018] [Indexed: 10/16/2022]
Abstract
In this work, an ultrasensitive electrochemiluminescence (ECL) method was established for the detection of trace amount of Ag ions (Ag+). In sulfuric acid medium, Ag(II), the electro-oxidized product of Ag(I), oxidizes manganese ions (Mn2+) to produce permanganate (MnO4-) by using a pair of graphite catheters as electrodes. While permanganate and luminol can produce strong chemiluminescence, based on the catalytic effect of Ag(II) on Mn2+ oxidation, there is a good linear relationship between the concentration of Ag+ and luminescence intensity. Under optimized conditions, the linear range of this method for Ag+ is from 0.2 to 150 nM with a detection limit of 0.06 nM. The method was applied for determination of Ag+ in various water samples with satisfactory results.
Collapse
Affiliation(s)
- Zhengping Ji
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, China
| | - Yun Shu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, China
| | - Qin Xu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, China.
| | - Xiaoya Hu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, China.
| |
Collapse
|
28
|
Wang CM, Hsieh CH, Chen CY, Liao WS. Low-voltage driven portable paper bipolar electrode-supported electrochemical sensing device. Anal Chim Acta 2018. [PMID: 29530247 DOI: 10.1016/j.aca.2018.02.041] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Aiming to overcome the obstacles of power supply requirement and chip usefulness in practice, a low-cost and convenient portable electrochemical sensing device is introduced for the first time, featuring bipolar electrode system, LED read-out, laminated paper-based devices, and low-voltage button cells. The electric circuits of this practical device are constructed on laminating films with copper and conductive carbon tapes, and the reservoirs facilitating chemical reactions are made with chromatography paper. The device is sensitive to electrochemical responses, validated by the demonstrative hydrogen peroxide and enzyme-assisted glucose detection. The business-card-size chip achieves sensitive analyte detection by naked eyes as well as further image processing in both laboratory samples and human serum samples testing, featuring detection limit as low as 1.79 μM and a dynamic range from 10 μM to 10 mM. This new practical design of point-of-care sensing chip entails the properties of facile fabrication, simple usage, high robustness, low power consumption, and accurate sensing showing the attainability of fabricating a useful and portable analytical device.
Collapse
Affiliation(s)
- Chang-Ming Wang
- Department of Chemistry, National Taiwan University, Taipei 10617, Taiwan
| | - Chia-Han Hsieh
- Department of Chemistry, National Taiwan University, Taipei 10617, Taiwan
| | - Chong-You Chen
- Department of Chemistry, National Taiwan University, Taipei 10617, Taiwan
| | - Wei-Ssu Liao
- Department of Chemistry, National Taiwan University, Taipei 10617, Taiwan.
| |
Collapse
|
29
|
A simple microdroplet chip consisting of silica nanochannel-assisted electrode and paper cover for highly sensitive electrochemiluminescent detection of drugs in human serum. Anal Chim Acta 2017; 983:96-102. [DOI: 10.1016/j.aca.2017.06.014] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Revised: 05/14/2017] [Accepted: 06/15/2017] [Indexed: 11/18/2022]
|
30
|
Bipolar electrochemiluminescence on thread: A new class of electroanalytical sensors. Biosens Bioelectron 2017; 94:335-343. [DOI: 10.1016/j.bios.2017.03.007] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2016] [Revised: 02/12/2017] [Accepted: 03/06/2017] [Indexed: 11/22/2022]
|
31
|
Zhang X, Zhai Q, Xing H, Li J, Wang E. Bipolar Electrodes with 100% Current Efficiency for Sensors. ACS Sens 2017; 2:320-326. [PMID: 28723210 DOI: 10.1021/acssensors.7b00031] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A bipolar electrode (BPE) is an electron conductor that is embedded in the electrolyte solution without the direct connection with the external power source (driving electrode). When the sufficient voltage was provided, the two poles of BPE promote different oxidation and reduction reactions. During the past few years, BPEs with wireless feature and easy integration showed great promise in the various fields including asymmetric modification/synthesis, motion control, targets enrichment/separation, and chemical sensing/biosensing combined with the quantitative relationship between two poles of BPE. In this perspective paper, we first describe the concept and history of the BPE for analytical chemistry and then review the recent developments in the application of BPEs for sensing with ultrahigh current efficiency (ηc = iBPE/ichannel) including the open and closed bipolar system. Finally, we offer the guide for possible challenge faced and solution in the future.
Collapse
Affiliation(s)
- Xiaowei Zhang
- State
Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China
- Graduate School of the Chinese Academy of Sciences, Beijing, 100039, P. R. China
| | - Qingfeng Zhai
- State
Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China
- Graduate School of the Chinese Academy of Sciences, Beijing, 100039, P. R. China
| | - Huanhuan Xing
- State
Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China
- Graduate School of the Chinese Academy of Sciences, Beijing, 100039, P. R. China
| | - Jing Li
- State
Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China
- Graduate School of the Chinese Academy of Sciences, Beijing, 100039, P. R. China
| | - Erkang Wang
- State
Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China
- Graduate School of the Chinese Academy of Sciences, Beijing, 100039, P. R. China
| |
Collapse
|
32
|
Chauhan P, Chu K, Yan N, Ding Z. Comparison study of electrochemiluminescence of boron-dipyrromethene (BODIPY) dyes in aprotic and aqueous solutions. J Electroanal Chem (Lausanne) 2016. [DOI: 10.1016/j.jelechem.2016.06.022] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
33
|
Zhang JD, Zhao WW, Xu JJ, Chen HY. Electrochemical behaviors in closed bipolar system with three-electrode driving mode. J Electroanal Chem (Lausanne) 2016. [DOI: 10.1016/j.jelechem.2016.10.017] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
34
|
Liu M, Liu R, Wang D, Liu C, Zhang C. A low-cost, ultraflexible cloth-based microfluidic device for wireless electrochemiluminescence application. LAB ON A CHIP 2016; 16:2860-2870. [PMID: 27356231 DOI: 10.1039/c6lc00289g] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The rising need for low-cost diagnostic devices has led to the search for inexpensive matrices that allow performing alternative analytical assays. Cloth is a viable material for the development of analytical devices due to its low material and manufacture costs, ability to wick assay fluids by capillary forces, and potential for patterning multiplexed channel geometries. In this paper, we describe the construction of low-cost, ultraflexible microfluidic cloth-based analytical devices (μCADs) for wireless electrochemiluminescence based on closed bipolar electrodes (C-WL-ECL), employing extremely cheap materials and a manufacturing process. The C-WL-ECL μCADs are built with wax-screen-printed cloth channels and carbon ink screen-printed electrodes, and the estimated cost per device is only $0.015. To demonstrate the performance of C-WL-ECL μCADs, the two most commonly used ECL systems - tris(2,2'-bipyridyl)ruthenium(ii)/tri-n-propylamine (Ru(bpy)3(2+)/TPA) and 3-aminophthalhydrazide/hydrogen peroxide (luminol/H2O2) - are applied. Under optimized conditions, the C-WL-ECL method has successfully fulfilled the quantitative determination of TPA with a detection limit of 0.085 mM. In addition, on the bent μCADs (bending angle (θ) = 180°), the luminol/H2O2-based ECL system can detect H2O2 as low as 0.024 mM. Based on such an ECL system, the bent μCADs are further used for determination of glucose in a phosphate buffer solution (PBS), with the detection limit of 0.195 mM. Finally, the applicability and validity, anti-interference ability, and storage stability of the C-WL-ECL μCADs are investigated. The results indicate that the proposed device has shown potential to extend the use of microfluidic analytical devices, due to its simplicity, low cost, ultraflexibility, and acceptable analytical performance.
Collapse
Affiliation(s)
- Min Liu
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, No. 55, Zhongshan Avenue West, Tianhe District, Guangzhou 510631, China.
| | | | | | | | | |
Collapse
|
35
|
de Poulpiquet A, Diez-Buitrago B, Dumont Milutinovic M, Sentic M, Arbault S, Bouffier L, Kuhn A, Sojic N. Dual Enzymatic Detection by Bulk Electrogenerated Chemiluminescence. Anal Chem 2016; 88:6585-92. [DOI: 10.1021/acs.analchem.6b01434] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Anne de Poulpiquet
- University of Bordeaux, ISM,
UMR 5255 CNRS, ENSCBP, 33607 Pessac, France
| | | | | | - Milica Sentic
- University of Bordeaux, ISM,
UMR 5255 CNRS, ENSCBP, 33607 Pessac, France
| | - Stéphane Arbault
- University of Bordeaux, ISM,
UMR 5255 CNRS, ENSCBP, 33607 Pessac, France
| | - Laurent Bouffier
- University of Bordeaux, ISM,
UMR 5255 CNRS, ENSCBP, 33607 Pessac, France
| | - Alexander Kuhn
- University of Bordeaux, ISM,
UMR 5255 CNRS, ENSCBP, 33607 Pessac, France
| | - Neso Sojic
- University of Bordeaux, ISM,
UMR 5255 CNRS, ENSCBP, 33607 Pessac, France
| |
Collapse
|
36
|
Bouffier L, Arbault S, Kuhn A, Sojic N. Generation of electrochemiluminescence at bipolar electrodes: concepts and applications. Anal Bioanal Chem 2016; 408:7003-11. [DOI: 10.1007/s00216-016-9606-9] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2016] [Revised: 04/20/2016] [Accepted: 04/26/2016] [Indexed: 10/21/2022]
|
37
|
Oja SM, Zhang B. Electrogenerated Chemiluminescence Reporting on Closed Bipolar Microelectrodes and the Influence of Electrode Size. ChemElectroChem 2016; 3:457-464. [PMID: 27500079 PMCID: PMC4972099 DOI: 10.1002/celc.201500352] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2015] [Indexed: 11/11/2022]
Abstract
We report a fundamental study of the use of Ru(bpy)32+-based electrogenerated chemiluminescence (ECL) as an optical reporting system for the detection of redox-active analyte on closed bipolar microelectrodes, focused on gaining an in-depth understanding of the correlation between ECL emission intensity and electrochemical current. We demonstrate the significant effect that the size of the anodic and cathodic poles has on the resulting ECL signal and show how this influences the quantitative detection of analyte on a closed bipolar electrode. By carefully designing the geometry of the bipolar electrode, the detection performance of the system can be tuned to different analyte concentration ranges. We show that through a simple voltammetric study of the individual reactions, one can understand the coupled bipolar behavior and accurately predict the ECL signal response to a range of analyte concentrations, enabling the accurate prediction of calibration curves.
Collapse
Affiliation(s)
- Stephen M. Oja
- Department of Chemistry, University of Washington, Seattle, Washington, 98195-1700, United States
| | - Bo Zhang
- Department of Chemistry, University of Washington, Seattle, Washington, 98195-1700, United States
| |
Collapse
|
38
|
Xu W, Fu K, Ma C, Bohn PW. Closed bipolar electrode-enabled dual-cell electrochromic detectors for chemical sensing. Analyst 2016; 141:6018-6024. [DOI: 10.1039/c6an01415a] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Battery operation of a closed-BPE dual cell with colorimetric readout by smartphone camera yields a simple, inexpensive, field-deployable electrochemical sensor.
Collapse
Affiliation(s)
- Wei Xu
- Department of Chemistry and Biochemistry
- University of Notre Dame
- Notre Dame
- USA
| | - Kaiyu Fu
- Department of Chemistry and Biochemistry
- University of Notre Dame
- Notre Dame
- USA
| | - Chaoxiong Ma
- Department of Chemistry and Biochemistry
- University of Notre Dame
- Notre Dame
- USA
| | - Paul W. Bohn
- Department of Chemistry and Biochemistry
- University of Notre Dame
- Notre Dame
- USA
- Department of Chemical and Biomolecular Engineering
| |
Collapse
|
39
|
Li H, Garrigue P, Bouffier L, Arbault S, Kuhn A, Sojic N. Double remote electrochemical addressing and optical readout of electrochemiluminescence at the tip of an optical fiber. Analyst 2016; 141:4299-304. [DOI: 10.1039/c6an00652c] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
A double remote strategy based on wireless addressing and remote readout of electrochemiluminescence at the tip of an optical fiber is reported.
Collapse
Affiliation(s)
- Haidong Li
- University of Bordeaux
- ISM
- CNRS UMR 5255
- Pessac
- France
| | | | | | | | | | - Neso Sojic
- University of Bordeaux
- ISM
- CNRS UMR 5255
- Pessac
- France
| |
Collapse
|
40
|
Lu WX, Bao N, Ding SN. A bipolar electrochemiluminescence sensing platform based on pencil core and paper reservoirs. RSC Adv 2016. [DOI: 10.1039/c6ra01460g] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
A very simple, portable and disposable BPE-ECL sensing platform has been investigated using commercial pencil core and paper cells.
Collapse
Affiliation(s)
- Wen-Xiu Lu
- Jingsu Province Hi-Tech Key Laboratory for Bio-Medical Research
- School of Chemistry and Chemical Engineering
- Southeast University
- Nanjing 211189
- China
| | - Ning Bao
- School of Public Health
- Nantong University
- 226019 Nantong
- China
| | - Shou-Nian Ding
- Jingsu Province Hi-Tech Key Laboratory for Bio-Medical Research
- School of Chemistry and Chemical Engineering
- Southeast University
- Nanjing 211189
- China
| |
Collapse
|
41
|
Patabadige DEW, Jia S, Sibbitts J, Sadeghi J, Sellens K, Culbertson CT. Micro Total Analysis Systems: Fundamental Advances and Applications. Anal Chem 2015; 88:320-38. [DOI: 10.1021/acs.analchem.5b04310] [Citation(s) in RCA: 80] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Damith E. W. Patabadige
- Department
of Chemistry, Kansas State University, 213 CBC Building, Manhattan, Kansas 66506, United States
| | - Shu Jia
- Department
of Chemistry, Kansas State University, 213 CBC Building, Manhattan, Kansas 66506, United States
| | - Jay Sibbitts
- Department
of Chemistry, Kansas State University, 213 CBC Building, Manhattan, Kansas 66506, United States
| | - Jalal Sadeghi
- Department
of Chemistry, Kansas State University, 213 CBC Building, Manhattan, Kansas 66506, United States
- Laser & Plasma Research Institute, Shahid Beheshti University, Evin, Tehran, 1983963113, Iran
| | - Kathleen Sellens
- Department
of Chemistry, Kansas State University, 213 CBC Building, Manhattan, Kansas 66506, United States
| | - Christopher T. Culbertson
- Department
of Chemistry, Kansas State University, 213 CBC Building, Manhattan, Kansas 66506, United States
| |
Collapse
|
42
|
Vertically Ordered Silica Mesochannel Modified Bipolar Electrode for Electrochemiluminescence Imaging Analysis. ChemElectroChem 2015. [DOI: 10.1002/celc.201500329] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
43
|
|
44
|
Shayan M, Kiani A. Digital versatile disc bipolar electrode: A fast and low-cost approach for visual sensing of analytes and electrocatalysts screening. Anal Chim Acta 2015; 888:52-8. [DOI: 10.1016/j.aca.2015.07.014] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2015] [Revised: 07/26/2015] [Accepted: 07/28/2015] [Indexed: 12/01/2022]
|
45
|
Khoshfetrat SM, Ranjbari M, Shayan M, Mehrgardi MA, Kiani A. Wireless Electrochemiluminescence Bipolar Electrode Array for Visualized Genotyping of Single Nucleotide Polymorphism. Anal Chem 2015; 87:8123-31. [DOI: 10.1021/acs.analchem.5b02515] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
| | - Mitra Ranjbari
- Department of Chemistry, University of Isfahan, Isfahan 81746-73441, Iran
| | - Mohsen Shayan
- Department of Chemistry, University of Isfahan, Isfahan 81746-73441, Iran
| | | | - Abolfazl Kiani
- Department of Chemistry, University of Isfahan, Isfahan 81746-73441, Iran
| |
Collapse
|
46
|
Zhang X, Chen C, Yin J, Han Y, Li J, Wang E. Portable and Visual Electrochemical Sensor Based on the Bipolar Light Emitting Diode Electrode. Anal Chem 2015; 87:4612-6. [DOI: 10.1021/acs.analchem.5b01018] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Affiliation(s)
- Xiaowei Zhang
- State
Key Laboratory of Electroanalytical Chemistry, Changchun Institute
of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, P. R. China
- Graduate School of the Chinese Academy of Sciences, Beijing, 100039, P. R. China
| | - Chaogui Chen
- State
Key Laboratory of Electroanalytical Chemistry, Changchun Institute
of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, P. R. China
- Graduate School of the Chinese Academy of Sciences, Beijing, 100039, P. R. China
| | - Jianyuan Yin
- Department
of Traditional Chinese Medicinal Chemistry, Pharmacy College, Jilin University, Changchun 130021, P. R. China
| | - Yanchao Han
- State
Key Laboratory of Electroanalytical Chemistry, Changchun Institute
of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, P. R. China
- Graduate School of the Chinese Academy of Sciences, Beijing, 100039, P. R. China
| | - Jing Li
- State
Key Laboratory of Electroanalytical Chemistry, Changchun Institute
of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, P. R. China
- Graduate School of the Chinese Academy of Sciences, Beijing, 100039, P. R. China
| | - Erkang Wang
- State
Key Laboratory of Electroanalytical Chemistry, Changchun Institute
of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, P. R. China
- Graduate School of the Chinese Academy of Sciences, Beijing, 100039, P. R. China
| |
Collapse
|
47
|
Kirschbaum SEK, Baeumner AJ. A review of electrochemiluminescence (ECL) in and for microfluidic analytical devices. Anal Bioanal Chem 2015; 407:3911-26. [DOI: 10.1007/s00216-015-8557-x] [Citation(s) in RCA: 76] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2014] [Revised: 01/12/2015] [Accepted: 02/10/2015] [Indexed: 12/31/2022]
|
48
|
Zhang JD, Yu T, Li JY, Xu JJ, Chen HY. An ITO bipolar array for electrochemiluminescence imaging of H2O2. Electrochem commun 2014. [DOI: 10.1016/j.elecom.2014.08.013] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022] Open
|
49
|
Zhang X, Li J, Jia X, Li D, Wang E. Full-Featured Electrochemiluminescence Sensing Platform Based on the Multichannel Closed Bipolar System. Anal Chem 2014; 86:5595-9. [DOI: 10.1021/ac501246k] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Affiliation(s)
- Xiaowei Zhang
- State Key Laboratory
of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China
- Graduate School of the Chinese Academy of Sciences, Beijing 100039, P. R. China
| | - Jing Li
- State Key Laboratory
of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China
| | - Xiaofang Jia
- State Key Laboratory
of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China
- Graduate School of the Chinese Academy of Sciences, Beijing 100039, P. R. China
| | - Dongyue Li
- State Key Laboratory
of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China
- Graduate School of the Chinese Academy of Sciences, Beijing 100039, P. R. China
| | - Erkang Wang
- State Key Laboratory
of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China
| |
Collapse
|
50
|
Fosdick SE, Berglund SP, Mullins CB, Crooks RM. Evaluating Electrocatalysts for the Hydrogen Evolution Reaction Using Bipolar Electrode Arrays: Bi- and Trimetallic Combinations of Co, Fe, Ni, Mo, and W. ACS Catal 2014. [DOI: 10.1021/cs500168t] [Citation(s) in RCA: 74] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Affiliation(s)
- Stephen E. Fosdick
- Department
of Chemistry and the Center for Nano- and Molecular Science and Technology, The University of Texas at Austin, 105 East 24th Street, Stop A5300, Austin, Texas, 78712-0165, United States
| | - Sean P. Berglund
- McKetta
Department of Chemical Engineering, The University of Texas at Austin, 200 East Dean Keeton Street, Stop C0400, Austin, Texas 78712-1589, United States
| | - C. Buddie Mullins
- Department
of Chemistry and the Center for Nano- and Molecular Science and Technology, The University of Texas at Austin, 105 East 24th Street, Stop A5300, Austin, Texas, 78712-0165, United States
- McKetta
Department of Chemical Engineering, The University of Texas at Austin, 200 East Dean Keeton Street, Stop C0400, Austin, Texas 78712-1589, United States
| | - Richard M. Crooks
- Department
of Chemistry and the Center for Nano- and Molecular Science and Technology, The University of Texas at Austin, 105 East 24th Street, Stop A5300, Austin, Texas, 78712-0165, United States
| |
Collapse
|