1
|
Doran MM, Bermingham KP, Tricklebank MD, Lowry JP. Characterisation of a microelectrochemical biosensor for real-time detection of brain extracellular d-serine. Talanta 2024; 278:126458. [PMID: 38955102 DOI: 10.1016/j.talanta.2024.126458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 06/14/2024] [Accepted: 06/19/2024] [Indexed: 07/04/2024]
Abstract
A modified development protocol and concomitant characterisation of a first generation biosensor for the detection of brain extracellular d-serine is reported. Functional parameters important for neurochemical monitoring, including sensor sensitivity, O2 interference, selectivity, shelf-life and biocompatibility were examined. Construction and development involved the enzyme d-amino acid oxidase (DAAO), utilising a dip-coating immobilisation method employing a new extended drying approach. The resultant Pt-based polymer enzyme composite sensor achieved high sensitivity to d-serine (0.76 ± 0.04 nA mm-2. μM-1) and a low μM limit of detection (0.33 ± 0.02 μM). The in-vitro response time was within the solution stirring time, suggesting potential sub-second in-vivo response characteristics. Oxygen interference studies demonstrated a 1 % reduction in current at 50 μM O2 when compared to atmospheric O2 levels (200 μM), indicating that the sensor can be used for reliable neurochemical monitoring of d-serine, free from changes in current associated with physiological O2 fluctuations. Potential interference signals generated by the principal electroactive analytes present in the brain were minimised by using a permselective layer of poly(o-phenylenediamine), and although several d-amino acids are possible substrates for DAAO, their physiologically relevant signals were small relative to that for d-serine. Additionally, changing both temperature and pH over possible in vivo ranges (34-40 °C and 7.2-7.6 respectively) resulted in no significant effect on performance. Finally, the biosensor was implanted in the striatum of freely moving rats and used to monitor physiological changes in d-serine over a two-week period.
Collapse
Affiliation(s)
- Michelle M Doran
- Neurochemistry Laboratory, Maynooth University Department of Chemistry, Maynooth University, Maynooth, Co. Kildare, Ireland.
| | - Kobi P Bermingham
- Neurochemistry Laboratory, Maynooth University Department of Chemistry, Maynooth University, Maynooth, Co. Kildare, Ireland
| | - Mark D Tricklebank
- Department of Neuroimaging Sciences, Institute of Psychiatry, Psychology & Neuroscience, King's College London, UK
| | - John P Lowry
- Neurochemistry Laboratory, Maynooth University Department of Chemistry, Maynooth University, Maynooth, Co. Kildare, Ireland.
| |
Collapse
|
2
|
Robbins E, Wong B, Pwint MY, Salavatian S, Mahajan A, Cui XT. Improving Sensitivity and Longevity of In Vivo Glutamate Sensors with Electrodeposited NanoPt. ACS APPLIED MATERIALS & INTERFACES 2024; 16:40570-40580. [PMID: 39078097 PMCID: PMC11310907 DOI: 10.1021/acsami.4c06692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 07/24/2024] [Accepted: 07/24/2024] [Indexed: 07/31/2024]
Abstract
In vivo glutamate sensing has provided valuable insight into the physiology and pathology of the brain. Electrochemical glutamate biosensors, constructed by cross-linking glutamate oxidase onto an electrode and oxidizing H2O2 as a proxy for glutamate, are the gold standard for in vivo glutamate measurements for many applications. While glutamate sensors have been employed ubiquitously for acute measurements, there are almost no reports of long-term, chronic glutamate sensing in vivo, despite demonstrations of glutamate sensors lasting for weeks in vitro. To address this, we utilized a platinum electrode with nanometer-scale roughness (nanoPt) to improve the glutamate sensors' sensitivity and longevity. NanoPt improved the GLU sensitivity by 67.4% and the sensors were stable in vitro for 3 weeks. In vivo, nanoPt glutamate sensors had a measurable signal above a control electrode on the same array for 7 days. We demonstrate the utility of the nanoPt sensors by studying the effect of traumatic brain injury on glutamate in the rat striatum with a flexible electrode array and report measurements of glutamate taken during the injury itself. We also show the flexibility of the nanoPt platform to be applied to other oxidase enzyme-based biosensors by measuring γ-aminobutyric acid in the porcine spinal cord. NanoPt is a simple, effective way to build high sensitivity, robust biosensors harnessing enzymes to detect neurotransmitters in vivo.
Collapse
Affiliation(s)
- Elaine
M. Robbins
- Department
of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
| | - Benjamin Wong
- Department
of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
- Department
of Anesthesiology & Perioperative Medicine, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania 15261, United States
| | - May Yoon Pwint
- Department
of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
- Center
for Neural Basis of Cognition, University
of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
| | - Siamak Salavatian
- Department
of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
- Department
of Anesthesiology & Perioperative Medicine, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania 15261, United States
| | - Aman Mahajan
- Department
of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
- Department
of Anesthesiology & Perioperative Medicine, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania 15261, United States
| | - Xinyan Tracy Cui
- Department
of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
- Center
for Neural Basis of Cognition, University
of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
- McGowan
Institute for Regenerative Medicine, University
of Pittsburgh, Pittsburgh, Pennsylvania 15261, United
States
| |
Collapse
|
3
|
Meng Z, Zhang Y, Yang L, Zhao S, Zhou Q, Chen J, Sui J, Wang J, Guo L, Chang L, He J, Wang G, Zang G. A Novel Poly(3-hexylthiophene) Engineered Interface for Electrochemical Monitoring of Ascorbic Acid During the Occurrence of Glutamate-Induced Brain Cytotoxic Edemas. RESEARCH (WASHINGTON, D.C.) 2023; 6:0149. [PMID: 37234604 PMCID: PMC10205589 DOI: 10.34133/research.0149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Accepted: 04/27/2023] [Indexed: 05/28/2023]
Abstract
Although neuroelectrochemical sensing technology offers unique benefits for neuroscience research, its application is limited by substantial interference in complex brain environments while ensuring biosafety requirements. In this study, we introduced poly(3-hexylthiophene) (P3HT) and nitrogen-doped multiwalled carbon nanotubes (N-MWCNTs) to construct a composite membrane-modified carbon fiber microelectrode (CFME/P3HT-N-MWCNTs) for ascorbic acid (AA) detection. The microelectrode presented good linearity, selectivity, stability, antifouling, and biocompatibility and exhibited great performance for application in neuroelectrochemical sensing. Subsequently, we applied CFME/P3HT-N-MWCNTs to monitor AA release from in vitro nerve cells, ex vivo brain slices, and in vivo living rat brains and determined that glutamate can induce cell edema and AA release. We also found that glutamate activated the N-methyl-d-aspartic acid receptor, which enhanced Na+ and Cl- inflow to induce osmotic stress, resulting in cytotoxic edema and ultimately AA release. This study is the first to observe the process of glutamate-induced brain cytotoxic edema with AA release and to reveal the mechanism. Our work can benefit the application of P3HT in in vivo implant microelectrode construction to monitor neurochemicals, understand the molecular basis of nervous system diseases, and discover certain biomarkers of brain diseases.
Collapse
Affiliation(s)
- Zexuan Meng
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching and Management Center,
Chongqing Medical University, Chongqing 400016, China
| | - Yuchan Zhang
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching and Management Center,
Chongqing Medical University, Chongqing 400016, China
| | - Lu Yang
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching and Management Center,
Chongqing Medical University, Chongqing 400016, China
| | - Shuang Zhao
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants,
Bioengineering College of Chongqing University, Chongqing 400030, China
- Jinfeng Laboratory, Chongqing 401329, China
| | - Qiang Zhou
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching and Management Center,
Chongqing Medical University, Chongqing 400016, China
- Department of Pathophysiology,
Chongqing Medical University, Chongqing, China
| | - Jiajia Chen
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching and Management Center,
Chongqing Medical University, Chongqing 400016, China
| | - Jiuxi Sui
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching and Management Center,
Chongqing Medical University, Chongqing 400016, China
| | - Jian Wang
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching and Management Center,
Chongqing Medical University, Chongqing 400016, China
| | - Lizhong Guo
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching and Management Center,
Chongqing Medical University, Chongqing 400016, China
| | - Luyue Chang
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching and Management Center,
Chongqing Medical University, Chongqing 400016, China
| | - Jialing He
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants,
Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Guixue Wang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants,
Bioengineering College of Chongqing University, Chongqing 400030, China
- Jinfeng Laboratory, Chongqing 401329, China
| | - Guangchao Zang
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching and Management Center,
Chongqing Medical University, Chongqing 400016, China
- Jinfeng Laboratory, Chongqing 401329, China
- Department of Pathophysiology,
Chongqing Medical University, Chongqing, China
| |
Collapse
|
4
|
Chang H, Huo M, Zhang Q, Zhou M, Zhang Y, Si Y, Zhang D, Guo Y, Fang Y. Flexible needle-type Microbiosensor for real-time monitoring traditional acupuncture-mediated adenosine release In vivo. Biosens Bioelectron 2023; 235:115383. [PMID: 37207583 DOI: 10.1016/j.bios.2023.115383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 04/19/2023] [Accepted: 05/08/2023] [Indexed: 05/21/2023]
Abstract
Rapid adenosine (ADO) signaling, on the time frame of seconds, regulates physiological and pathological processes, including the therapeutic efficacy of acupuncture. Nevertheless, standard monitoring strategies are limited by poor temporal resolution. Herein, an implantable needle-type microsensor capable of monitoring ADO release in vivo in response to acupuncture in real time has been developed. Electrocatalytic Prussian Blue nanoparticles, an immobilized multienzyme system, and a permselective poly-o-phenylenediamine-based membrane were used for the sequential modification of the sensing region of the electrode. The resultant sensor can perform amperometric measurements of ADO levels in response to a very low level of applied potential (-0.05 V vs Ag/AgCl). This microsensor also functioned across a broad linear range (0-50 μM) and exhibited good sensitivity (1.1 nA/μM) with a rapid response time of under 5 s. Importantly, the sensor also exhibited good reproducibility and high selectivity. For in vivo animal studies, the microsensor was employed for the continuous assessment of instantaneous ADO release at the ST36 (Zusanli) acupoint when this acupoint was subjected to twirling-rotating acupuncture manipulation. Benefiting from superior sensor in vivo performance and stability, the positive correlation between the variability in acupuncture-induced ADO release and the stimulus intensity levels that affect the clinical benefit can be demonstrated for the first time. Overall, these results highlight a powerful approach to analyzing the in vivo physiological effects of acupuncture, expanding application realm of micro-nano sensor technology on a fast time scale.
Collapse
Affiliation(s)
- Hongen Chang
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin, 301617, PR China
| | - Mingzhu Huo
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin, 301617, PR China
| | - Qingxiang Zhang
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin, 301617, PR China
| | - Mengmeng Zhou
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin, 301617, PR China
| | - Youlin Zhang
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin, 301617, PR China
| | - Yuxin Si
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin, 301617, PR China
| | - Di Zhang
- College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, 301617, PR China; State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, PR China; Haihe Laboratory of Modern Chinese Medicine, Tianjin, 301617, PR China.
| | - Yi Guo
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin, 301617, PR China.
| | - Yuxin Fang
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin, 301617, PR China.
| |
Collapse
|
5
|
Design optimisation and characterisation of an amperometric glutamate oxidase-based composite biosensor for neurotransmitter l-glutamic acid. Anal Chim Acta 2022; 1224:340205. [DOI: 10.1016/j.aca.2022.340205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 07/15/2022] [Accepted: 07/24/2022] [Indexed: 11/22/2022]
|
6
|
Khan ZM, Wilts E, Vlaisavljevich E, Long TE, Verbridge SS. Electroresponsive Hydrogels for Therapeutic Applications in the Brain. Macromol Biosci 2021; 22:e2100355. [PMID: 34800348 DOI: 10.1002/mabi.202100355] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 10/29/2021] [Indexed: 12/22/2022]
Abstract
Electroresponsive hydrogels possess a conducting material component and respond to electric stimulation through reversible absorption and expulsion of water. The high level of hydration, soft elastomeric compliance, biocompatibility, and enhanced electrochemical properties render these hydrogels suitable for implantation in the brain to enhance the transmission of neural electric signals and ion transport. This review provides an overview of critical electroresponsive hydrogel properties for augmenting electric stimulation in the brain. A background on electric stimulation in the brain through electroresponsive hydrogels is provided. Common conducting materials and general techniques to integrate them into hydrogels are briefly discussed. This review focuses on and summarizes advances in electric stimulation of electroconductive hydrogels for therapeutic applications in the brain, such as for controlling delivery of drugs, directing neural stem cell differentiation and neurogenesis, improving neural biosensor capabilities, and enhancing neural electrode-tissue interfaces. The key challenges in each of these applications are discussed and recommendations for future research are also provided.
Collapse
Affiliation(s)
- Zerin M Khan
- Virginia Tech - Wake Forest University School of Biomedical Engineering and Sciences, Virginia Tech, Blacksburg, VA, 24061, USA
| | - Emily Wilts
- Department of Cellular and Physiological Sciences, University of British Columbia, Vancouver, British Columbia, V6T 1Z3, Canada
| | - Eli Vlaisavljevich
- Virginia Tech - Wake Forest University School of Biomedical Engineering and Sciences, Virginia Tech, Blacksburg, VA, 24061, USA
| | - Timothy E Long
- Biodesign Center for Sustainable Macromolecular Materials and Manufacturing, Arizona State University, Tempe, AZ, 85287, USA
| | - Scott S Verbridge
- Virginia Tech - Wake Forest University School of Biomedical Engineering and Sciences, Virginia Tech, Blacksburg, VA, 24061, USA
| |
Collapse
|
7
|
Recent advances of electrochemical sensors for detecting and monitoring ROS/RNS. Biosens Bioelectron 2021; 179:113052. [DOI: 10.1016/j.bios.2021.113052] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2020] [Revised: 01/24/2021] [Accepted: 01/26/2021] [Indexed: 02/07/2023]
|
8
|
Marquitan M, Mark MD, Ernst A, Muhs A, Herlitze S, Ruff A, Schuhmann W. Glutamate detection at the cellular level by means of polymer/enzyme multilayer modified carbon nanoelectrodes. J Mater Chem B 2020; 8:3631-3639. [DOI: 10.1039/c9tb02461a] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Carbon nanoelectrodes in the sub-micron range were modified with an enzyme cascade immobilized in a spatially separated polymer double layer system for the detection of glutamate at the cellular level.
Collapse
Affiliation(s)
- Miriam Marquitan
- Analytical Chemistry – Center for Electrochemical Sciences (CES)
- Faculty of Chemistry and Biochemistry
- Ruhr University Bochum
- D-44780 Bochum
- Germany
| | - Melanie D. Mark
- Department of General Zoology and Neurobiology Ruhr University Bochum Universitätsstr. 150
- D-44780 Bochum
- Germany
| | - Andrzej Ernst
- Analytical Chemistry – Center for Electrochemical Sciences (CES)
- Faculty of Chemistry and Biochemistry
- Ruhr University Bochum
- D-44780 Bochum
- Germany
| | - Anna Muhs
- Analytical Chemistry – Center for Electrochemical Sciences (CES)
- Faculty of Chemistry and Biochemistry
- Ruhr University Bochum
- D-44780 Bochum
- Germany
| | - Stefan Herlitze
- Department of General Zoology and Neurobiology Ruhr University Bochum Universitätsstr. 150
- D-44780 Bochum
- Germany
| | - Adrian Ruff
- Analytical Chemistry – Center for Electrochemical Sciences (CES)
- Faculty of Chemistry and Biochemistry
- Ruhr University Bochum
- D-44780 Bochum
- Germany
| | - Wolfgang Schuhmann
- Analytical Chemistry – Center for Electrochemical Sciences (CES)
- Faculty of Chemistry and Biochemistry
- Ruhr University Bochum
- D-44780 Bochum
- Germany
| |
Collapse
|
9
|
Sung C, Jeon W, Nam KS, Kim Y, Butt H, Park S. Multimaterial and multifunctional neural interfaces: from surface-type and implantable electrodes to fiber-based devices. J Mater Chem B 2020; 8:6624-6666. [DOI: 10.1039/d0tb00872a] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Development of neural interfaces from surface electrodes to fibers with various type, functionality, and materials.
Collapse
Affiliation(s)
- Changhoon Sung
- Department of Bio and Brain Engineering
- Korea Advanced Institute of Science and Technology (KAIST)
- Daejeon 34141
- Republic of Korea
| | - Woojin Jeon
- Department of Bio and Brain Engineering
- Korea Advanced Institute of Science and Technology (KAIST)
- Daejeon 34141
- Republic of Korea
| | - Kum Seok Nam
- School of Electrical Engineering
- Korea Advanced Institute of Science and Technology (KAIST)
- Daejeon 34141
- Republic of Korea
| | - Yeji Kim
- Department of Bio and Brain Engineering
- Korea Advanced Institute of Science and Technology (KAIST)
- Daejeon 34141
- Republic of Korea
| | - Haider Butt
- Department of Mechanical Engineering
- Khalifa University
- Abu Dhabi 127788
- United Arab Emirates
| | - Seongjun Park
- Department of Bio and Brain Engineering
- Korea Advanced Institute of Science and Technology (KAIST)
- Daejeon 34141
- Republic of Korea
- KAIST Institute for Health Science and Technology (KIHST)
| |
Collapse
|
10
|
Peng Q, Yan X, Shi X, Ou S, Gu H, Yin X, Shi G, Yu Y. In vivo monitoring of superoxide anion from Alzheimer's rat brains with functionalized ionic liquid polymer decorated microsensor. Biosens Bioelectron 2019; 144:111665. [DOI: 10.1016/j.bios.2019.111665] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Revised: 08/27/2019] [Accepted: 08/29/2019] [Indexed: 02/06/2023]
|
11
|
High spatial resolution electrochemical biosensing using reflected light microscopy. Sci Rep 2019; 9:15196. [PMID: 31645591 PMCID: PMC6811617 DOI: 10.1038/s41598-019-50949-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Accepted: 09/18/2019] [Indexed: 12/13/2022] Open
Abstract
If the analyte does not only change the electrochemical but also the optical properties of the electrode/solution interface, the spatial resolution of an electrochemical sensor can be substantially enhanced by combining the electrochemical sensor with optical microscopy. In order to demonstrate this, electrochemical biosensors for the detection of hydrogen peroxide and glucose were developed by drop casting enzyme and redox polymer mixtures onto planar, optically transparent electrodes. These biosensors generate current signals proportional to the analyte concentration via a reaction sequence which ultimately changes the oxidation state of the redox polymer. Images of the interface of these biosensors were acquired using bright field reflected light microscopy (BFRLM). Analysis showed that the intensity of these images is higher when the redox polymer is oxidized than when it is reduced. It also revealed that the time needed for the redox polymer to change oxidation state can be assayed optically and is dependent on the concentration of the analyte. By combining the biosensor for hydrogen peroxide detection with BFRLM, it was possible to determine hydrogen peroxide in concentrations as low as 12.5 µM with a spatial resolution of 12 µm × 12 µm, without the need for the fabrication of microelectrodes of these dimensions.
Collapse
|
12
|
Ou Y, Buchanan AM, Witt CE, Hashemi P. Frontiers in Electrochemical Sensors for Neurotransmitter Detection: Towards Measuring Neurotransmitters as Chemical Diagnostics for Brain Disorders. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2019; 11:2738-2755. [PMID: 32724337 PMCID: PMC7386554 DOI: 10.1039/c9ay00055k] [Citation(s) in RCA: 58] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
It is extremely challenging to chemically diagnose disorders of the brain. There is hence great interest in designing and optimizing tools for direct detection of chemical biomarkers implicated in neurological disorders to improve diagnosis and treatment. Tools that are capable of monitoring brain chemicals, neurotransmitters in particular, need to be biocompatible, perform with high spatiotemporal resolution, and ensure high selectivity and sensitivity. Recent advances in electrochemical methods are addressing these criteria; the resulting devices demonstrate great promise for in vivo neurotransmitter detection. None of these devices are currently used for diagnostic purposes, however these cutting-edge technologies are promising more sensitive, selective, faster, and less invasive measurements. Via this review we highlight significant technical advances and in vivo studies, performed in the last 5 years, that we believe will facilitate the development of diagnostic tools for brain disorders.
Collapse
Affiliation(s)
- Yangguang Ou
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia SC
| | - Anna Marie Buchanan
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia SC
| | - Colby E. Witt
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia SC
| | - Parastoo Hashemi
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia SC
| |
Collapse
|
13
|
Wang W, Zhao F, Li M, Zhang C, Shao Y, Tian Y. A SERS Optophysiological Probe for the Real‐Time Mapping and Simultaneous Determination of the Carbonate Concentration and pH Value in a Live Mouse Brain. Angew Chem Int Ed Engl 2019. [DOI: 10.1002/ange.201814286] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Weikang Wang
- Shanghai Key Laboratory of Green Chemistry and Chemical ProcessesEast China Normal University Dongchuan Road 500 Shanghai 200241 China
| | - Fan Zhao
- Shanghai Key Laboratory of Green Chemistry and Chemical ProcessesEast China Normal University Dongchuan Road 500 Shanghai 200241 China
| | - Mingzhi Li
- Beijing National Laboratory for Molecular SciencesCollege of Chemistry and Molecular EngineeringPeking University Beijing 100871 China
| | - Chuanping Zhang
- Shanghai Key Laboratory of Green Chemistry and Chemical ProcessesEast China Normal University Dongchuan Road 500 Shanghai 200241 China
| | - Yuanhua Shao
- Beijing National Laboratory for Molecular SciencesCollege of Chemistry and Molecular EngineeringPeking University Beijing 100871 China
| | - Yang Tian
- Shanghai Key Laboratory of Green Chemistry and Chemical ProcessesEast China Normal University Dongchuan Road 500 Shanghai 200241 China
| |
Collapse
|
14
|
Wang W, Zhao F, Li M, Zhang C, Shao Y, Tian Y. A SERS Optophysiological Probe for the Real-Time Mapping and Simultaneous Determination of the Carbonate Concentration and pH Value in a Live Mouse Brain. Angew Chem Int Ed Engl 2019; 58:5256-5260. [PMID: 30811077 DOI: 10.1002/anie.201814286] [Citation(s) in RCA: 66] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2018] [Revised: 02/01/2019] [Indexed: 01/02/2023]
Abstract
To have a profound understanding of the physiological and pathological processes in a brain, both chemical and electrical signals need to be recorded, but this is still very challenging. Herein, micrometer- to nanometer-sized SERS optophysiological probes were created to determine both the CO3 2- concentration and the pH in live brains and neurons because both species play important roles in regulating the acid-base balance in the brain. A ratiometric SERS microarray of eight microprobes with tip sizes of 5 μm was established and used for the first time for real-time mapping and simultaneous quantification of CO3 2- and pH in a live brain. We found that both the CO3 2- concentration and the pH value dramatically decreased under ischemic conditions. The present SERS technique can be combined with electrophysiology without cross-talk to record both electrical and chemical signals in brains. To deepen our understanding of the mechanism of ischemia on the single-cell level, a SERS nanoprobe with a tip size of 200 nm was developed for use in a single neuron.
Collapse
Affiliation(s)
- Weikang Wang
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, East China Normal University, Dongchuan Road 500, Shanghai, 200241, China
| | - Fan Zhao
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, East China Normal University, Dongchuan Road 500, Shanghai, 200241, China
| | - Mingzhi Li
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing, 100871, China
| | - Chuanping Zhang
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, East China Normal University, Dongchuan Road 500, Shanghai, 200241, China
| | - Yuanhua Shao
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing, 100871, China
| | - Yang Tian
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, East China Normal University, Dongchuan Road 500, Shanghai, 200241, China
| |
Collapse
|
15
|
Nguyen TNH, Nolan JK, Park H, Lam S, Fattah M, Page JC, Joe HE, Jun MBG, Lee H, Kim SJ, Shi R, Lee H. Facile fabrication of flexible glutamate biosensor using direct writing of platinum nanoparticle-based nanocomposite ink. Biosens Bioelectron 2019; 131:257-266. [PMID: 30849725 DOI: 10.1016/j.bios.2019.01.051] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Revised: 01/18/2019] [Accepted: 01/28/2019] [Indexed: 01/23/2023]
Abstract
Glutamate excitotoxicity is a pathology in which excessive glutamate can cause neuronal damage and degeneration. It has also been linked to secondary injury mechanisms in traumatic spinal cord injury. Conventional bioanalytical techniques used to characterize glutamate levels in vivo, such as microdialysis, have low spatiotemporal resolution, which has impeded our understanding of this dynamic event. In this study, we present an amperometric biosensor fabricated using a simple direct ink writing technique for the purpose of in vivo glutamate monitoring. The biosensor is fabricated by immobilizing glutamate oxidase on nanocomposite electrodes made of platinum nanoparticles, multi-walled carbon nanotubes, and a conductive polymer on a flexible substrate. The sensor is designed to measure extracellular dynamics of glutamate and other potential biomarkers during a traumatic spinal cord injury event. Here we demonstrate good sensitivity and selectivity of these rapidly prototyped implantable biosensors that can be inserted into a spinal cord and measure extracellular glutamate concentration. We show that our biosensors exhibit good flexibility, linear range, repeatability, and stability that are suitable for future in vivo evaluation.
Collapse
Affiliation(s)
- Tran N H Nguyen
- Weldon School of Biomedical Engineering, Birck Nanotechnology Center, Center for Implantable Device, Purdue University, West Lafayette, IN, USA
| | - James K Nolan
- Weldon School of Biomedical Engineering, Birck Nanotechnology Center, Center for Implantable Device, Purdue University, West Lafayette, IN, USA
| | - Hyunsu Park
- Weldon School of Biomedical Engineering, Birck Nanotechnology Center, Center for Implantable Device, Purdue University, West Lafayette, IN, USA
| | - Stephanie Lam
- Weldon School of Biomedical Engineering, Birck Nanotechnology Center, Center for Implantable Device, Purdue University, West Lafayette, IN, USA
| | - Mara Fattah
- School of Mechanical Engineering, Purdue University, West Lafayette, IN, USA
| | - Jessica C Page
- College of Veterinary Medicine, Purdue University, West Lafayette, IN, USA
| | - Hang-Eun Joe
- School of Mechanical Engineering, Purdue University, West Lafayette, IN, USA
| | - Martin B G Jun
- School of Mechanical Engineering, Purdue University, West Lafayette, IN, USA
| | - Hyungwoo Lee
- Samsung Advanced Institute of Technology, Suwon, South Korea
| | - Sang Joon Kim
- Samsung Advanced Institute of Technology, Suwon, South Korea
| | - Riyi Shi
- Weldon School of Biomedical Engineering, Birck Nanotechnology Center, Center for Implantable Device, Purdue University, West Lafayette, IN, USA; College of Veterinary Medicine, Purdue University, West Lafayette, IN, USA
| | - Hyowon Lee
- Weldon School of Biomedical Engineering, Birck Nanotechnology Center, Center for Implantable Device, Purdue University, West Lafayette, IN, USA.
| |
Collapse
|
16
|
Characterisation of a Platinum-based Electrochemical Biosensor for Real-time Neurochemical Analysis of Choline. ELECTROANAL 2018. [DOI: 10.1002/elan.201800642] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
17
|
Isoaho N, Peltola E, Sainio S, Koskinen J, Laurila T. Pt-grown carbon nanofibers for enzymatic glutamate biosensors and assessment of their biocompatibility. RSC Adv 2018; 8:35802-35812. [PMID: 35547905 PMCID: PMC9088215 DOI: 10.1039/c8ra07766e] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Accepted: 10/09/2018] [Indexed: 01/11/2023] Open
Abstract
Application-specific carbon nanofibers grown from Pt-catalyst layers have been shown to be a promising material for biosensor development. Here we demonstrate immobilization of glutamate oxidase on them and their use for amperometric detection of glutamate at two different potentials. At -0.15 V vs. Ag/AgCl at concentrations higher than 100 μM the oxygen reduction reaction severely interferes with the enzymatic production of H2O2 and consequently affects the detection of glutamate. On the other hand, at 0.6 V vs. Ag/AgCl enzyme saturation starts to affect the measurement above a glutamate concentration of 100 μM. Moreover, we suggest here that glutamate itself might foul Pt surfaces to some degree, which should be taken into account when designing Pt-based sensors operating at high anodic potentials. Finally, the Pt-grown and Ni-grown carbon nanofibers were shown to be biocompatible. However, the cells on Pt-grown carbon nanofibers had different morphology and formation of filopodia compared to those on Ni-grown carbon nanofibers. The effect was expected to be caused rather by the different fiber dimensions between the samples than the catalyst metal itself. Further experiments are required to find the optimal dimensions of CNFs for biological purposes.
Collapse
Affiliation(s)
- Noora Isoaho
- Department of Electrical Engineering and Automation, School of Electrical Engineering, Aalto University PO Box 13500 00076 Aalto Finland +358 50 341 4375
| | - Emilia Peltola
- Department of Electrical Engineering and Automation, School of Electrical Engineering, Aalto University PO Box 13500 00076 Aalto Finland +358 50 341 4375
| | - Sami Sainio
- Department Chemistry and Materials Science, School of Chemical Technology, Aalto University PO Box 16200 00076 Aalto Finland
| | - Jari Koskinen
- Department Chemistry and Materials Science, School of Chemical Technology, Aalto University PO Box 16200 00076 Aalto Finland
| | - Tomi Laurila
- Department of Electrical Engineering and Automation, School of Electrical Engineering, Aalto University PO Box 13500 00076 Aalto Finland +358 50 341 4375
| |
Collapse
|
18
|
Nanomaterials-Based Electrochemical Sensors for In Vitro and In Vivo Analyses of Neurotransmitters. APPLIED SCIENCES-BASEL 2018. [DOI: 10.3390/app8091504] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Neurotransmitters are molecules that transfer chemical signals between neurons to convey messages for any action conducted by the nervous system. All neurotransmitters are medically important; the detection and analysis of these molecules play vital roles in the diagnosis and treatment of diseases. Among analytical strategies, electrochemical techniques have been identified as simple, inexpensive, and less time-consuming processes. Electrochemical analysis is based on the redox behaviors of neurotransmitters, as well as their metabolites. A variety of electrochemical techniques are available for the detection of biomolecules. However, the development of a sensing platform with high sensitivity and selectivity is challenging, and it has been found to be a bottleneck step in the analysis of neurotransmitters. Nanomaterials-based sensor platforms are fascinating for researchers because of their ability to perform the electrochemical analysis of neurotransmitters due to their improved detection efficacy, and they have been widely reported on for their sensitive detection of epinephrine, dopamine, serotonin, glutamate, acetylcholine, nitric oxide, and purines. The advancement of electroanalytical technologies and the innovation of functional nanomaterials have been assisting greatly in in vivo and in vitro analyses of neurotransmitters, especially for point-of-care clinical applications. In this review, firstly, we focus on the most commonly employed electrochemical analysis techniques, in conjunction with their working principles and abilities for the detection of neurotransmitters. Subsequently, we concentrate on the fabrication and development of nanomaterials-based electrochemical sensors and their advantages over other detection techniques. Finally, we address the challenges and the future outlook in the development of electrochemical sensors for the efficient detection of neurotransmitters.
Collapse
|
19
|
Pál B. Involvement of extrasynaptic glutamate in physiological and pathophysiological changes of neuronal excitability. Cell Mol Life Sci 2018; 75:2917-2949. [PMID: 29766217 PMCID: PMC11105518 DOI: 10.1007/s00018-018-2837-5] [Citation(s) in RCA: 79] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2018] [Revised: 04/27/2018] [Accepted: 05/07/2018] [Indexed: 12/14/2022]
Abstract
Glutamate is the most abundant neurotransmitter of the central nervous system, as the majority of neurons use glutamate as neurotransmitter. It is also well known that this neurotransmitter is not restricted to synaptic clefts, but found in the extrasynaptic regions as ambient glutamate. Extrasynaptic glutamate originates from spillover of synaptic release, as well as from astrocytes and microglia. Its concentration is magnitudes lower than in the synaptic cleft, but receptors responding to it have higher affinity for it. Extrasynaptic glutamate receptors can be found in neuronal somatodendritic location, on astroglia, oligodendrocytes or microglia. Activation of them leads to changes of neuronal excitability with different amplitude and kinetics. Extrasynaptic glutamate is taken up by neurons and astrocytes mostly via EAAT transporters, and astrocytes, in turn metabolize it to glutamine. Extrasynaptic glutamate is involved in several physiological phenomena of the central nervous system. It regulates neuronal excitability and synaptic strength by involving astroglia; contributing to learning and memory formation, neurosecretory and neuromodulatory mechanisms, as well as sleep homeostasis.The extrasynaptic glutamatergic system is affected in several brain pathologies related to excitotoxicity, neurodegeneration or neuroinflammation. Being present in dementias, neurodegenerative and neuropsychiatric diseases or tumor invasion in a seemingly uniform way, the system possibly provides a common component of their pathogenesis. Although parts of the system are extensively discussed by several recent reviews, in this review I attempt to summarize physiological actions of the extrasynaptic glutamate on neuronal excitability and provide a brief insight to its pathology for basic understanding of the topic.
Collapse
Affiliation(s)
- Balázs Pál
- Department of Physiology, Faculty of Medicine, University of Debrecen, Nagyerdei krt 98, Debrecen, 4012, Hungary.
| |
Collapse
|
20
|
Chatard C, Meiller A, Marinesco S. Microelectrode Biosensors forin vivoAnalysis of Brain Interstitial Fluid. ELECTROANAL 2018. [DOI: 10.1002/elan.201700836] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Charles Chatard
- INSERM U1028, CNRS UMR5292; Lyon Neuroscience Research Center, Team TIGER
- Université Claude Bernard Lyon 1; Lyon France
| | - Anne Meiller
- AniRA-Neurochem Technological Platform; Lyon France
- Université Claude Bernard Lyon 1; Lyon France
| | - Stéphane Marinesco
- INSERM U1028, CNRS UMR5292; Lyon Neuroscience Research Center, Team TIGER
- AniRA-Neurochem Technological Platform; Lyon France
- Université Claude Bernard Lyon 1; Lyon France
- Lyon Neuroscience Research Center, Team TIGER; Faculty of Medicine; 8 Avenue Rockefeller 69373 Lyon Cedex 08 France
| |
Collapse
|
21
|
Clay M, Monbouquette HG. A Detailed Model of Electroenzymatic Glutamate Biosensors To Aid in Sensor Optimization and in Applications in Vivo. ACS Chem Neurosci 2018; 9:241-251. [PMID: 29076724 DOI: 10.1021/acschemneuro.7b00262] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
Simulations conducted with a detailed model of glutamate biosensor performance describe the observed sensor performance well, illustrate the limits of sensor performance, and suggest a path toward sensor optimization. Glutamate is the most important excitatory neurotransmitter in the brain, and electroenzymatic sensors have emerged as a useful tool for the monitoring of glutamate signaling in vivo. However, the utility of these sensors currently is limited by their sensitivity and response time. A mathematical model of a typical glutamate biosensor consisting of a Pt electrode coated with a permselective polymer film and a top layer of cross-linked glutamate oxidase has been constructed in terms of differential material balances on glutamate, H2O2, and O2 in one spatial dimension. Simulations suggest that reducing thicknesses of the permselective polymer and enzyme layers can increase sensitivity ∼6-fold and reduce response time ∼7-fold, and thereby improve resolution of transient glutamate signals. At currently employed enzyme layer thicknesses, both intrinsic enzyme kinetics and enzyme deactivation likely are masked by mass transfer. However, O2-dependence studies show essentially no reduction in signal at the lowest anticipated O2 concentrations for expected glutamate concentrations in the brain and that O2 transport limitations in vitro are anticipated only at glutamate concentrations in the mM range. Finally, the limitations of current biosensors in monitoring glutamate transients is simulated and used to illustrate the need for optimized biosensors to report glutamate signaling accurately on a subsecond time scale. This work demonstrates how a detailed model can be used to guide optimization of electroenzymatic sensors similar to that for glutamate and to ensure appropriate interpretation of data gathered using such biosensors.
Collapse
Affiliation(s)
- Mackenzie Clay
- Chemical and Biomolecular
Engineering Department, University of California, Los Angeles, Los Angeles, California 90095-1592, United States
| | - Harold G. Monbouquette
- Chemical and Biomolecular
Engineering Department, University of California, Los Angeles, Los Angeles, California 90095-1592, United States
| |
Collapse
|
22
|
Advances in Nano Based Biosensors for Food and Agriculture. ENVIRONMENTAL CHEMISTRY FOR A SUSTAINABLE WORLD 2018. [DOI: 10.1007/978-3-319-70166-0_1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
23
|
Liu L, Zhao F, Liu W, Zhu T, Zhang JZH, Chen C, Dai Z, Peng H, Huang JL, Hu Q, Bu W, Tian Y. An Electrochemical Biosensor with Dual Signal Outputs: Toward Simultaneous Quantification of pH and O2
in the Brain upon Ischemia and in a Tumor during Cancer Starvation Therapy. Angew Chem Int Ed Engl 2017. [DOI: 10.1002/anie.201705615] [Citation(s) in RCA: 66] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Affiliation(s)
- Li Liu
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes; School of Chemistry and Molecular Engineering; East China Normal University; Dongchuan Road 500 Shanghai 200241 China
- Jiangsu Collaborative Innovation Centre of Biomedical Functional Materials and Jiangsu Key Laboratory of Biofunctional Materials; School of Chemistry and Materials Science; Nanjing Normal University; Nanjing 210023 China
| | - Fan Zhao
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes; School of Chemistry and Molecular Engineering; East China Normal University; Dongchuan Road 500 Shanghai 200241 China
| | - Wei Liu
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes; School of Chemistry and Molecular Engineering; East China Normal University; Dongchuan Road 500 Shanghai 200241 China
| | - Tong Zhu
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes; School of Chemistry and Molecular Engineering; East China Normal University; Dongchuan Road 500 Shanghai 200241 China
| | - John Z. H. Zhang
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes; School of Chemistry and Molecular Engineering; East China Normal University; Dongchuan Road 500 Shanghai 200241 China
| | - Chen Chen
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes; School of Chemistry and Molecular Engineering; East China Normal University; Dongchuan Road 500 Shanghai 200241 China
| | - Zhihui Dai
- Jiangsu Collaborative Innovation Centre of Biomedical Functional Materials and Jiangsu Key Laboratory of Biofunctional Materials; School of Chemistry and Materials Science; Nanjing Normal University; Nanjing 210023 China
| | - Huisheng Peng
- State Key Laboratory of Molecular Engineering of Polymers; Department of Macromolecular Science and Laboratory of Advanced Materials; Department of Chemistry; Fudan University; China
| | - Jun-Long Huang
- Discipline of Neuroscience; Department of Anatomy, Histology and Embryology; Shanghai Jiao Tong University School of Medicine; Shanghai China
| | - Qin Hu
- Discipline of Neuroscience; Department of Anatomy, Histology and Embryology; Shanghai Jiao Tong University School of Medicine; Shanghai China
| | - Wenbo Bu
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes; School of Chemistry and Molecular Engineering; East China Normal University; Dongchuan Road 500 Shanghai 200241 China
| | - Yang Tian
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes; School of Chemistry and Molecular Engineering; East China Normal University; Dongchuan Road 500 Shanghai 200241 China
| |
Collapse
|
24
|
Liu L, Zhao F, Liu W, Zhu T, Zhang JZH, Chen C, Dai Z, Peng H, Huang JL, Hu Q, Bu W, Tian Y. An Electrochemical Biosensor with Dual Signal Outputs: Toward Simultaneous Quantification of pH and O2
in the Brain upon Ischemia and in a Tumor during Cancer Starvation Therapy. Angew Chem Int Ed Engl 2017. [DOI: 10.1002/ange.201705615] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Affiliation(s)
- Li Liu
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes; School of Chemistry and Molecular Engineering; East China Normal University; Dongchuan Road 500 Shanghai 200241 China
- Jiangsu Collaborative Innovation Centre of Biomedical Functional Materials and Jiangsu Key Laboratory of Biofunctional Materials; School of Chemistry and Materials Science; Nanjing Normal University; Nanjing 210023 China
| | - Fan Zhao
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes; School of Chemistry and Molecular Engineering; East China Normal University; Dongchuan Road 500 Shanghai 200241 China
| | - Wei Liu
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes; School of Chemistry and Molecular Engineering; East China Normal University; Dongchuan Road 500 Shanghai 200241 China
| | - Tong Zhu
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes; School of Chemistry and Molecular Engineering; East China Normal University; Dongchuan Road 500 Shanghai 200241 China
| | - John Z. H. Zhang
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes; School of Chemistry and Molecular Engineering; East China Normal University; Dongchuan Road 500 Shanghai 200241 China
| | - Chen Chen
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes; School of Chemistry and Molecular Engineering; East China Normal University; Dongchuan Road 500 Shanghai 200241 China
| | - Zhihui Dai
- Jiangsu Collaborative Innovation Centre of Biomedical Functional Materials and Jiangsu Key Laboratory of Biofunctional Materials; School of Chemistry and Materials Science; Nanjing Normal University; Nanjing 210023 China
| | - Huisheng Peng
- State Key Laboratory of Molecular Engineering of Polymers; Department of Macromolecular Science and Laboratory of Advanced Materials; Department of Chemistry; Fudan University; China
| | - Jun-Long Huang
- Discipline of Neuroscience; Department of Anatomy, Histology and Embryology; Shanghai Jiao Tong University School of Medicine; Shanghai China
| | - Qin Hu
- Discipline of Neuroscience; Department of Anatomy, Histology and Embryology; Shanghai Jiao Tong University School of Medicine; Shanghai China
| | - Wenbo Bu
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes; School of Chemistry and Molecular Engineering; East China Normal University; Dongchuan Road 500 Shanghai 200241 China
| | - Yang Tian
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes; School of Chemistry and Molecular Engineering; East China Normal University; Dongchuan Road 500 Shanghai 200241 China
| |
Collapse
|
25
|
Li S, Zhu A, Zhu T, Zhang JZH, Tian Y. Single Biosensor for Simultaneous Quantification of Glucose and pH in a Rat Brain of Diabetic Model Using Both Current and Potential Outputs. Anal Chem 2017; 89:6656-6662. [DOI: 10.1021/acs.analchem.7b00881] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Affiliation(s)
- Shuai Li
- Shanghai Key Laboratory of
Green Chemistry and Chemical Processes, School of Chemistry and Molecular
Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, People’s Republic of China
| | - Anwei Zhu
- Shanghai Key Laboratory of
Green Chemistry and Chemical Processes, School of Chemistry and Molecular
Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, People’s Republic of China
| | - Tong Zhu
- Shanghai Key Laboratory of
Green Chemistry and Chemical Processes, School of Chemistry and Molecular
Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, People’s Republic of China
| | - John Z. H. Zhang
- Shanghai Key Laboratory of
Green Chemistry and Chemical Processes, School of Chemistry and Molecular
Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, People’s Republic of China
| | - Yang Tian
- Shanghai Key Laboratory of
Green Chemistry and Chemical Processes, School of Chemistry and Molecular
Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, People’s Republic of China
| |
Collapse
|
26
|
Zhang H, Oellers T, Feng W, Abdulazim T, Saw EN, Ludwig A, Levkin PA, Plumeré N. High-Density Droplet Microarray of Individually Addressable Electrochemical Cells. Anal Chem 2017; 89:5832-5839. [DOI: 10.1021/acs.analchem.7b00008] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Affiliation(s)
- Huijie Zhang
- Center
for Electrochemical Sciences—CES, Ruhr-Universität Bochum, Universitätsstrasse 150, 44780 Bochum, Germany
| | - Tobias Oellers
- Chair
of MEMS Materials, Institute for Materials, Faculty of Mechanical
Engineering, Ruhr-Universität Bochum, Universitätsstrasse 150, 44780 Bochum, Germany
| | - Wenqian Feng
- Institute
of Toxicology and Genetics, Karlsruhe Institute of Technology (KIT), 76021 Karlsruhe, Germany
| | - Tarik Abdulazim
- Center
for Electrochemical Sciences—CES, Ruhr-Universität Bochum, Universitätsstrasse 150, 44780 Bochum, Germany
| | - En Ning Saw
- Center
for Electrochemical Sciences—CES, Ruhr-Universität Bochum, Universitätsstrasse 150, 44780 Bochum, Germany
| | - Alfred Ludwig
- Chair
of MEMS Materials, Institute for Materials, Faculty of Mechanical
Engineering, Ruhr-Universität Bochum, Universitätsstrasse 150, 44780 Bochum, Germany
| | - Pavel A. Levkin
- Institute
of Toxicology and Genetics, Karlsruhe Institute of Technology (KIT), 76021 Karlsruhe, Germany
- Institute
of Organic Chemistry, Karlsruhe Institute of Technology (KIT), 76021 Karlsruhe, Germany
| | - Nicolas Plumeré
- Center
for Electrochemical Sciences—CES, Ruhr-Universität Bochum, Universitätsstrasse 150, 44780 Bochum, Germany
| |
Collapse
|
27
|
Doran MM, Finnerty NJ, Lowry JP. In-Vitro
Development and Characterisation of a Superoxide Dismutase-Based Biosensor. ChemistrySelect 2017. [DOI: 10.1002/slct.201700793] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Affiliation(s)
- Michelle M. Doran
- Neurochemistry Laboratory, Maynooth University Department of Chemistry; Maynooth University; Maynooth Co. Kildare Ireland
| | - Niall J. Finnerty
- Neurochemistry Laboratory, Maynooth University Department of Chemistry; Maynooth University; Maynooth Co. Kildare Ireland
| | - John P. Lowry
- Neurochemistry Laboratory, Maynooth University Department of Chemistry; Maynooth University; Maynooth Co. Kildare Ireland
| |
Collapse
|
28
|
Weltin A, Kieninger J, Urban GA. Microfabricated, amperometric, enzyme-based biosensors for in vivo applications. Anal Bioanal Chem 2016; 408:4503-21. [PMID: 26935934 PMCID: PMC4909808 DOI: 10.1007/s00216-016-9420-4] [Citation(s) in RCA: 57] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2015] [Revised: 02/08/2016] [Accepted: 02/12/2016] [Indexed: 01/19/2023]
Abstract
Miniaturized electrochemical in vivo biosensors allow the measurement of fast extracellular dynamics of neurotransmitter and energy metabolism directly in the tissue. Enzyme-based amperometric biosensing is characterized by high specificity and precision as well as high spatial and temporal resolution. Aside from glucose monitoring, many systems have been introduced mainly for application in the central nervous system in animal models. We compare the microsensor principle with other methods applied in biomedical research to show advantages and drawbacks. Electrochemical sensor systems are easily miniaturized and fabricated by microtechnology processes. We review different microfabrication approaches for in vivo sensor platforms, ranging from simple modified wires and fibres to fully microfabricated systems on silicon, ceramic or polymer substrates. The various immobilization methods for the enzyme such as chemical cross-linking and entrapment in polymer membranes are discussed. The resulting sensor performance is compared in detail. We also examine different concepts to reject interfering substances by additional membranes, aspects of instrumentation and biocompatibility. Practical considerations are elaborated, and conclusions for future developments are presented. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Andreas Weltin
- Laboratory for Sensors, Department of Microsystems Engineering – IMTEK, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany
| | - Jochen Kieninger
- Laboratory for Sensors, Department of Microsystems Engineering – IMTEK, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany
| | - Gerald A. Urban
- Laboratory for Sensors, Department of Microsystems Engineering – IMTEK, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany
| |
Collapse
|
29
|
Dalkıran B, Erden PE, Kılıç E. Graphene and tricobalt tetraoxide nanoparticles based biosensor for electrochemical glutamate sensing. ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY 2016; 45:340-348. [PMID: 26939621 DOI: 10.3109/21691401.2016.1153482] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
An amperometric biosensor based on tricobalt tetraoxide nanoparticles (Co3O4), graphene (GR), and chitosan (CS) nanocomposite modified glassy carbon electrode (GCE) for sensitive determination of glutamate was fabricated. Scanning electron microscopy was implemented to characterize morphology of the nanocomposite. The biosensor showed optimum response within 25 s at pH 7.5 and 37 °C, at +0.70 V. The linear working range of biosensor for glutamate was from 4.0 × 10-6 to 6.0 × 10-4 M with a detection limit of 2.0 × 10-6 M and sensitivity of 0.73 μA/mM or 7.37 μA/mMcm2. The relatively low Michaelis-Menten constant (1.09 mM) suggested enhanced enzyme affinity to glutamate. The glutamate biosensor lost 45% of its initial activity after three weeks.
Collapse
Affiliation(s)
- Berna Dalkıran
- a Department of Chemistry , Ankara University, Faculty of Science , Tandoğan , Ankara , Turkey
| | - Pınar Esra Erden
- a Department of Chemistry , Ankara University, Faculty of Science , Tandoğan , Ankara , Turkey
| | - Esma Kılıç
- a Department of Chemistry , Ankara University, Faculty of Science , Tandoğan , Ankara , Turkey
| |
Collapse
|
30
|
Fang Y, Ramasamy RP. Current and Prospective Methods for Plant Disease Detection. BIOSENSORS 2015; 5:537-61. [PMID: 26287253 PMCID: PMC4600171 DOI: 10.3390/bios5030537] [Citation(s) in RCA: 183] [Impact Index Per Article: 20.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Revised: 07/01/2015] [Accepted: 07/14/2015] [Indexed: 01/08/2023]
Abstract
Food losses due to crop infections from pathogens such as bacteria, viruses and fungi are persistent issues in agriculture for centuries across the globe. In order to minimize the disease induced damage in crops during growth, harvest and postharvest processing, as well as to maximize productivity and ensure agricultural sustainability, advanced disease detection and prevention in crops are imperative. This paper reviews the direct and indirect disease identification methods currently used in agriculture. Laboratory-based techniques such as polymerase chain reaction (PCR), immunofluorescence (IF), fluorescence in-situ hybridization (FISH), enzyme-linked immunosorbent assay (ELISA), flow cytometry (FCM) and gas chromatography-mass spectrometry (GC-MS) are some of the direct detection methods. Indirect methods include thermography, fluorescence imaging and hyperspectral techniques. Finally, the review also provides a comprehensive overview of biosensors based on highly selective bio-recognition elements such as enzyme, antibody, DNA/RNA and bacteriophage as a new tool for the early identification of crop diseases.
Collapse
Affiliation(s)
- Yi Fang
- Nano Electrochemistry Laboratory, College of Engineering, University of Georgia, Athens, GA 30602, USA.
| | - Ramaraja P Ramasamy
- Nano Electrochemistry Laboratory, College of Engineering, University of Georgia, Athens, GA 30602, USA.
| |
Collapse
|
31
|
Amperometric l-glutamate biosensor based on bacterial cell-surface displayed glutamate dehydrogenase. Anal Chim Acta 2015; 884:83-9. [DOI: 10.1016/j.aca.2015.05.012] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2015] [Revised: 05/04/2015] [Accepted: 05/07/2015] [Indexed: 01/20/2023]
|
32
|
Ferreira NR, Lourenço C, Barbosa RM, Laranjinha J. Coupling of ascorbate and nitric oxide dynamics in vivo in the rat hippocampus upon glutamatergic neuronal stimulation: A novel functional interplay. Brain Res Bull 2015; 114:13-9. [DOI: 10.1016/j.brainresbull.2015.03.002] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2014] [Revised: 02/09/2015] [Accepted: 03/07/2015] [Indexed: 01/01/2023]
|
33
|
Nguyen CM, Rao S, Yang X, Dubey S, Mays J, Cao H, Chiao JC. Sol-gel deposition of iridium oxide for biomedical micro-devices. SENSORS (BASEL, SWITZERLAND) 2015; 15:4212-28. [PMID: 25686309 PMCID: PMC4367406 DOI: 10.3390/s150204212] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/17/2014] [Accepted: 02/06/2015] [Indexed: 12/04/2022]
Abstract
Flexible iridium oxide (IrOx)-based micro-electrodes were fabricated on flexible polyimide substrates using a sol-gel deposition process for utilization as integrated pseudo-reference electrodes for bio-electrochemical sensing applications. The fabrication method yields reliable miniature on-probe IrOx electrodes with long lifetime, high stability and repeatability. Such sensors can be used for long-term measurements. Various dimensions of sol-gel iridium oxide electrodes including 1 mm × 1 mm, 500 µm × 500 µm, and 100 µm × 100 µm were fabricated. Sensor longevity and pH dependence were investigated by immersing the electrodes in hydrochloric acid, fetal bovine serum (FBS), and sodium hydroxide solutions for 30 days. Less pH dependent responses, compared to IrOx electrodes fabricated by electrochemical deposition processes, were measured at 58.8 ± 0.4 mV/pH, 53.8 ± 1.3 mV/pH and 48 ± 0.6 mV/pH, respectively. The on-probe IrOx pseudo-reference electrodes were utilized for dopamine sensing. The baseline responses of the sensors were higher than the one using an external Ag/AgCl reference electrode. Using IrOx reference electrodes integrated on the same probe with working electrodes eliminated the use of cytotoxic Ag/AgCl reference electrode without loss in sensitivity. This enables employing such sensors in long-term recording of concentrations of neurotransmitters in central nervous systems of animals and humans.
Collapse
Affiliation(s)
- Cuong M Nguyen
- Department of Electrical Engineering, University of Texas, Arlington, TX 76019, USA.
| | - Smitha Rao
- Department of Electrical Engineering, University of Texas, Arlington, TX 76019, USA.
| | - Xuesong Yang
- Department of Electrical Engineering, University of Texas, Arlington, TX 76019, USA.
| | - Souvik Dubey
- Department of Electrical Engineering, University of Texas, Arlington, TX 76019, USA.
| | - Jeffrey Mays
- Department of Electrical Engineering, University of Texas, Arlington, TX 76019, USA.
| | - Hung Cao
- Department of Electrical Engineering, ETS, Montreal, QC H3C 1K3, Canada.
| | - Jung-Chih Chiao
- Department of Electrical Engineering, University of Texas, Arlington, TX 76019, USA.
| |
Collapse
|
34
|
Kopparthy VL, Tangutooru SM, Guilbeau EJ. Label Free Detection of L-Glutamate Using Microfluidic Based Thermal Biosensor. Bioengineering (Basel) 2015; 2:2-14. [PMID: 28955010 PMCID: PMC5597124 DOI: 10.3390/bioengineering2010002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2014] [Accepted: 01/07/2015] [Indexed: 01/09/2023] Open
Abstract
A thermoelectric biosensor for the detection of L-glutamate concentration was developed. The thermoelectric sensor is integrated into a micro-calorimeter which measures the heat produced by biochemical reactions. The device contains a single flow channel that is 120 µm high and 10 mm wide with two fluid inlets and one fluid outlet. An antimony-bismuth (Sb-Bi) thermopile with high common mode rejection ratio is attached to the lower channel wall and measures the dynamic changes in the temperature when L-glutamate undergoes oxidative deamination in the presence of glutamate oxidase (GLOD). The thermopile has a Seebeck coefficient of ~7 µV·(m·K)−1. The device geometry, together with hydrodynamic focusing, eliminates the need of extensive temperature control. Layer-by-layer assembly is used to immobilize GLOD on the surface of glass coverslips by alternate electrostatic adsorption of polyelectrolyte and GLOD. The impulse injection mode using a 6-port injection valve minimizes sample volume to 5 µL. The sensitivity of the sensor for glutamate is 17.9 nVs·mM−1 in the linear range of 0–54 mM with an R2 value of 0.9873. The lowest detection limit of the sensor for glutamate is 5.3 mM.
Collapse
Affiliation(s)
- Varun Lingaiah Kopparthy
- The Center for Biomedical Engineering and Rehabilitation Science, Louisiana Tech University, Ruston, LA 71272, USA.
| | - Siva Mahesh Tangutooru
- Department of Mechanical & Industrial Engineering, Qatar University, P.O. Box 2713, Doha, Qatar.
| | - Eric J Guilbeau
- The Center for Biomedical Engineering and Rehabilitation Science, Louisiana Tech University, Ruston, LA 71272, USA.
| |
Collapse
|
35
|
Wakabayashi KT, Myal SE, Kiyatkin EA. Fluctuations in nucleus accumbens extracellular glutamate and glucose during motivated glucose-drinking behavior: dissecting the neurochemistry of reward. J Neurochem 2015; 132:327-41. [PMID: 25393775 DOI: 10.1111/jnc.12993] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2014] [Revised: 10/17/2014] [Accepted: 11/10/2014] [Indexed: 12/21/2022]
Abstract
While motivated behavior involves multiple neurochemical systems, few studies have focused on the role of glutamate, the brain's excitatory neurotransmitter, and glucose, the energetic substrate of neural activity in reward-related neural processes. Here, we used high-speed amperometry with enzyme-based substrate-sensitive and control, enzyme-free biosensors to examine second-scale fluctuations in the extracellular levels of these substances in the nucleus accumbens shell during glucose-drinking behavior in trained rats. Glutamate rose rapidly after the presentation of a glucose-containing cup and before the initiation of drinking (reward seeking), decreased more slowly to levels below baseline during consumption (sensory reward), and returned to baseline when the ingested glucose reached the brain (metabolic reward). When water was substituted for glucose, glutamate rapidly increased with cup presentation and in contrast to glucose drinking, increased above baseline after rats tasted the water and refused to drink further. Therefore, extracellular glutamate show distinct changes associated with key events of motivated drinking behavior and opposite dynamics during sensory and metabolic components of reward. In contrast to glutamate, glucose increased at each stimulus and behavioral event, showing a sustained elevation during the entire behavior and a robust post-ingestion rise that correlated with the gradual return of glutamate levels to their baseline. By comparing active drinking with passive intra-gastric glucose delivery, we revealed that fluctuations in extracellular glucose are highly dynamic, reflecting a balance between rapid delivery because of neural activity, intense metabolism, and the influence of ingested glucose reaching the brain.
Collapse
Affiliation(s)
- Ken T Wakabayashi
- In-Vivo Electrophysiology Unit, Behavioral Neuroscience Branch, National Institute on Drug Abuse - Intramural Research Program, National Institutes of Health, DHHS, Baltimore, Maryland, USA
| | | | | |
Collapse
|
36
|
Cifuentes Castro VH, López Valenzuela CL, Salazar Sánchez JC, Peña KP, López Pérez SJ, Ibarra JO, Villagrán AM. An update of the classical and novel methods used for measuring fast neurotransmitters during normal and brain altered function. Curr Neuropharmacol 2014; 12:490-508. [PMID: 25977677 PMCID: PMC4428024 DOI: 10.2174/1570159x13666141223223657] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2014] [Revised: 11/22/2014] [Accepted: 12/19/2014] [Indexed: 11/22/2022] Open
Abstract
To understand better the cerebral functions, several methods have been developed to study the brain activity, they could be related with morphological, electrophysiological, molecular and neurochemical techniques. Monitoring neurotransmitter concentration is a key role to know better how the brain works during normal or pathological conditions, as well as for studying the changes in neurotransmitter concentration with the use of several drugs that could affect or reestablish the normal brain activity. Immediate response of the brain to environmental conditions is related with the release of the fast acting neurotransmission by glutamate (Glu), γ-aminobutyric acid (GABA) and acetylcholine (ACh) through the opening of ligand-operated ion channels. Neurotransmitter release is mainly determined by the classical microdialysis technique, this is generally coupled to high performance liquid chromatography (HPLC). Detection of neurotransmitters can be done by fluorescence, optical density, electrochemistry or other detection systems more sophisticated. Although the microdialysis method is the golden technique to monitor the brain neurotransmitters, it has a poor temporal resolution. Recently, with the use of biosensor the drawback of temporal resolution has been improved considerably, however other inconveniences have merged, such as stability, reproducibility and the lack of reliable biosensors mainly for GABA. The aim of this review is to show the important advances in the different ways to measure neurotransmitter concentrations; both with the use of classic techniques as well as with the novel methods and alternant approaches to improve the temporal resolution.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Alberto Morales Villagrán
- Department of Molecular and Cellular Biology, Camino Ramón Padilla Sánchez 2100, Nextipac, Zapopan,
Jalisco, México, Zip code: 45110, Mexico
| |
Collapse
|
37
|
Schmidt AC, Dunaway LE, Roberts JG, McCarty GS, Sombers LA. Multiple Scan Rate Voltammetry for Selective Quantification of Real-Time Enkephalin Dynamics. Anal Chem 2014; 86:7806-12. [DOI: 10.1021/ac501725u] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Andreas C. Schmidt
- Department of Chemistry, ‡Department of Biomedical Engineering, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Lars E. Dunaway
- Department of Chemistry, ‡Department of Biomedical Engineering, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - James G. Roberts
- Department of Chemistry, ‡Department of Biomedical Engineering, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Gregory S. McCarty
- Department of Chemistry, ‡Department of Biomedical Engineering, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Leslie A. Sombers
- Department of Chemistry, ‡Department of Biomedical Engineering, North Carolina State University, Raleigh, North Carolina 27695, United States
| |
Collapse
|
38
|
Sirca D, Vardeu A, Pinna M, Diana M, Enrico P. A robust, state-of-the-art amperometric microbiosensor for glutamate detection. Biosens Bioelectron 2014; 61:526-31. [PMID: 24951923 DOI: 10.1016/j.bios.2014.04.054] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2014] [Revised: 04/10/2014] [Accepted: 04/29/2014] [Indexed: 10/25/2022]
Abstract
Scientific knowledge of glutamate (GLU) neurobiology is severely hampered by the inadequacy of the available in vivo brain sampling techniques. Due to the crucial role of GLU in central nervous system function and pathology, the development of a reliable sampling device is mandatory. GLU biosensor holds potential to address many of the known issues of in vivo GLU measurement. We report here on the development and test of a labor- and cost-effective microbiosensor, suitable to be applied for measuring brain GLU. A glycerol-based cryopreservation method was also tested. Needle type Pt biosensors were coated with a permselective Nafion-Poly(o-phenylenediamine) layer and cross-linked to l-glutamate oxidase with poly(ethylene glycol) diglycidyl ether. Tested in vitro, the device shows high sensitivity and specificity for GLU, while being poorly influenced by common interfering substances such as ascorbate, dopamine and dihydroxyphenylacetic acid. Further, the cryopreservation procedure kept sensitivity unaltered for 30 days and possibly longer. We conclude that a highly efficient GLU biosensor of minimal dimensions can be consistently and affordably constructed with relative ease. Together with the possibility of cryopreservation this shall foster diffusion and exploitation of GLU biosensors technology.
Collapse
Affiliation(s)
- Donatella Sirca
- Department of Biomedical Sciences, University of Sassari, Sassari, Italy
| | - Antonella Vardeu
- Department of Biomedical Sciences, University of Sassari, Sassari, Italy
| | - Milo Pinna
- Department of Biomedical Sciences, University of Sassari, Sassari, Italy
| | - Marco Diana
- "G. Minardi" Laboratory of Cognitive Neuroscience, Department of Chemistry and Pharmacy, University of Sassari, Sassari, Italy
| | - Paolo Enrico
- Department of Biomedical Sciences, University of Sassari, Sassari, Italy
| |
Collapse
|
39
|
Tseng TTC, Chang CF, Chan WC. Fabrication of implantable, enzyme-immobilized glutamate sensors for the monitoring of glutamate concentration changes in vitro and in vivo. Molecules 2014; 19:7341-55. [PMID: 24905604 PMCID: PMC6271204 DOI: 10.3390/molecules19067341] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2014] [Revised: 05/30/2014] [Accepted: 06/03/2014] [Indexed: 11/16/2022] Open
Abstract
Glutamate sensors based on the immobilization of glutamate oxidase (GlutOx) were prepared by adsorption on electrodeposited chitosan (Method 1) and by crosslinking with glutaraldehyde (Method 2) on micromachined platinum microelectrodes. It was observed that glutamate sensors prepared by Method 1 have faster response time (<2 s) and lower detection limit (2.5 ± 1.1 μM) compared to that prepared by Method 2 (response time: <5 sec and detection limit: 6.5 ± 1.7 μM); glutamate sensors prepared by Method 2 have a larger linear detection range (20–352 μM) and higher sensitivity (86.8 ± 8.8 nA·μM−1·cm−2, N = 12) compared to those prepared by Method 1 (linear detection range: 20–217 μM and sensitivity: 34.9 ± 4.8 nA·μM−1·cm−2, N = 8). The applicability of the glutamate sensors in vivo was also demonstrated. The glutamate sensors were implanted into the rat brain to monitor the stress-induced extracellular glutamate release in the hypothalamus of the awake, freely moving rat.
Collapse
Affiliation(s)
- Tina T-C Tseng
- Department of Chemical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan.
| | - Cheng-Fu Chang
- Department of Neurosurgery, Taipei Medical University Hospital, Taipei 11031, Taiwan.
| | - Wen-Chin Chan
- Department of Chemical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan.
| |
Collapse
|
40
|
Weltin A, Kieninger J, Enderle B, Gellner AK, Fritsch B, Urban GA. Polymer-based, flexible glutamate and lactate microsensors for in vivo applications. Biosens Bioelectron 2014; 61:192-9. [PMID: 24880657 DOI: 10.1016/j.bios.2014.05.014] [Citation(s) in RCA: 69] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2014] [Revised: 05/02/2014] [Accepted: 05/06/2014] [Indexed: 12/28/2022]
Abstract
We present a flexible microsensor, based on a polymer substrate, for multiparametric, electrochemical in vivo monitoring. The sensor strip with a microelectrode array at the tip was designed for insertion into tissue, for fast and localized online monitoring of physiological parameters. The microsystem fabrication on a wafer-level is based on a polyimide substrate and includes the patterning of platinum microelectrodes as well as epoxy and dry-film-resist insulation in a cost-effective thin-film and laminate process. A stable, electrodeposited silver/silver chloride reference electrode on-chip and a perm-selective membrane as an efficient interference rejection scheme are integrated on a wafer-level. Amperometric, electrochemical, enzyme-based biosensors for the neurotransmitter L-glutamate and the energy metabolite L-lactate have been developed. Hydrogel membranes or direct cross-linking as stable concepts for the enzyme immobilization are shown. Sensor performance including high selectivity, tailoring of sensitivity and long-term stability is discussed. For glutamate, a high sensitivity of 2.16 nAmm(-2) µM(-1) was found. For lactate, a variation in sensitivity between 2.6 and 32 nAmm(-2)mM(-1) was achieved by different membrane compositions. The in vivo application in an animal model is demonstrated by glutamate measurements in the brain of rats. Local glutamate alterations in the micromolar range and in nanoliter-range volumes can be detected and quantified with high reproducibility and temporal resolution. A novel, versatile platform for the integration of various electrochemical sensors on a small, flexible sensor strip for a variety of in vivo applications is presented.
Collapse
Affiliation(s)
- Andreas Weltin
- Laboratory for Sensors, Department of Microsystems Engineering - IMTEK, University of Freiburg, Germany.
| | - Jochen Kieninger
- Laboratory for Sensors, Department of Microsystems Engineering - IMTEK, University of Freiburg, Germany
| | - Barbara Enderle
- Laboratory for Sensors, Department of Microsystems Engineering - IMTEK, University of Freiburg, Germany
| | | | - Brita Fritsch
- Department of Neurology, University of Freiburg, Germany
| | - Gerald A Urban
- Laboratory for Sensors, Department of Microsystems Engineering - IMTEK, University of Freiburg, Germany
| |
Collapse
|
41
|
Xiang L, Yu P, Hao J, Zhang M, Zhu L, Dai L, Mao L. Vertically Aligned Carbon Nanotube-Sheathed Carbon Fibers as Pristine Microelectrodes for Selective Monitoring of Ascorbate in Vivo. Anal Chem 2014; 86:3909-14. [DOI: 10.1021/ac404232h] [Citation(s) in RCA: 88] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Ling Xiang
- Beijing
National Laboratory for Molecular Sciences, Key Laboratory of Analytical
Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Ping Yu
- Beijing
National Laboratory for Molecular Sciences, Key Laboratory of Analytical
Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Jie Hao
- Beijing
National Laboratory for Molecular Sciences, Key Laboratory of Analytical
Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Meining Zhang
- Department
of Chemistry, Renmin University of China, Beijing 100872, China
| | - Lin Zhu
- Department
of Macromolecular Science and Engineering, Case Western Reserve University, Cleveland, Ohio 44106, United States
| | - Liming Dai
- Department
of Macromolecular Science and Engineering, Case Western Reserve University, Cleveland, Ohio 44106, United States
| | - Lanqun Mao
- Beijing
National Laboratory for Molecular Sciences, Key Laboratory of Analytical
Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| |
Collapse
|
42
|
Polcari D, Kwan A, Van Horn MR, Danis L, Pollegioni L, Ruthazer ES, Mauzeroll J. Disk-shaped amperometric enzymatic biosensor for in vivo detection of D-serine. Anal Chem 2014; 86:3501-7. [PMID: 24650010 DOI: 10.1021/ac404111u] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
At the synapse, D-serine is an endogenous co-agonist for the N-methyl-D-aspartate receptor (NMDAR). It plays an important role in synaptic transmission and plasticity and has also been linked to several pathological diseases such as schizophrenia and Huntington's. The quantification of local changes in D-serine concentration is essential to further understanding these processes. We report herein the development of a disk-shaped amperometric enzymatic biosensor for detection of D-serine based on a 25 μm diameter platinum disk microelectrode with an electrodeposited poly-m-phenylenediamine (PPD) layer and an R. gracilis D-amino acid oxidase (RgDAAO) layer. The disk-shaped D-serine biosensor is 1-5 orders of magnitude smaller than previously reported probes and exhibits a sensitivity of 276 μA cm(-2) mM(-1) with an in vitro detection limit of 0.6 μM. We demonstrate its usefulness for in vivo applications by measuring the release of endogenous D-serine in the brain of Xenopus laevis tadpoles.
Collapse
Affiliation(s)
- David Polcari
- Department of Chemistry, McGill University , 801 Sherbrooke Street West, Montreal, Quebec, Canada H3A 0B8
| | | | | | | | | | | | | |
Collapse
|
43
|
Wakabayashi KT, Kiyatkin EA. Critical role of peripheral drug actions in experience-dependent changes in nucleus accumbens glutamate release induced by intravenous cocaine. J Neurochem 2013; 128:672-85. [PMID: 24111505 DOI: 10.1111/jnc.12472] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2013] [Revised: 09/26/2013] [Accepted: 09/27/2013] [Indexed: 11/28/2022]
Abstract
Recent studies reveal that cocaine experience results in persistent neuroadaptive changes within glutamate (Glu) synapses in brain areas associated with drug reward. However, it remains unclear whether cocaine affects Glu release in drug-naive animals and how it is altered by drug experience. Using high-speed amperometry with enzyme-based and enzyme-free biosensors in freely moving rats, we show that an initial intravenous cocaine injection at a low self-administering dose (1 mg/kg) induces rapid, small and transient Glu release in the nucleus accumbens shell (NAc), which with subsequent injections rapidly becomes a much stronger, two-component increase. Using cocaine-methiodide, cocaine's analog that does not cross the blood-brain barrier, we confirm that the initial cocaine-induced Glu release in the NAc has a peripheral neural origin. Unlike cocaine, Glu responses induced by cocaine-methiodide rapidly habituate following repeated exposure. However, after cocaine experience this drug induces cocaine-like Glu responses. Hence, the interoceptive actions of cocaine, which essentially precede its direct actions in the brain, play a critical role in experience-dependent alterations in Glu release, cocaine-induced neural sensitization and may contribute to cocaine addiction. Using high-speed amperometry with enzyme-based biosensors in freely moving rats, we show that initial intravenous cocaine induces rapid, transient glutamate (Glu) release in the Nac (Nucleus accumbens), rapidly becoming a stronger, two-component increase with subsequent injections. We show that the peripheral actions of cocaine, which precedes its direct central actions, play a critical role in experience-dependent alterations in Glu release, possibly contributing to cocaine addiction.
Collapse
Affiliation(s)
- Ken T Wakabayashi
- In-Vivo Electrophysiology Unit, Behavioral Neuroscience Branch, National Institute on Drug Abuse - Intramural Research Program, National Institutes of Health, DHHS, Baltimore, Maryland, USA
| | | |
Collapse
|
44
|
Liu K, Yu P, Lin Y, Wang Y, Ohsaka T, Mao L. Online Electrochemical Monitoring of Dynamic Change of Hippocampal Ascorbate: Toward a Platform for In Vivo Evaluation of Antioxidant Neuroprotective Efficiency against Cerebral Ischemia Injury. Anal Chem 2013; 85:9947-54. [DOI: 10.1021/ac402620c] [Citation(s) in RCA: 72] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- Kun Liu
- Beijing
National Laboratory for Molecular Sciences, Key Laboratory of Analytical
Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing 100190, P. R. China
- Capital University of Physical Education and Sports, Beijing 100191, P. R. China
| | - Ping Yu
- Beijing
National Laboratory for Molecular Sciences, Key Laboratory of Analytical
Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing 100190, P. R. China
| | - Yuqing Lin
- Beijing
National Laboratory for Molecular Sciences, Key Laboratory of Analytical
Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing 100190, P. R. China
| | - Yuexiang Wang
- Beijing
National Laboratory for Molecular Sciences, Key Laboratory of Analytical
Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing 100190, P. R. China
| | - Takeo Ohsaka
- Department
of Electronic Chemistry, Interdisciplinary Graduate School of Science
and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama 226-8502, Japan
| | - Lanqun Mao
- Beijing
National Laboratory for Molecular Sciences, Key Laboratory of Analytical
Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing 100190, P. R. China
| |
Collapse
|
45
|
Selective enzyme immobilization on arrayed microelectrodes for the application of sensing neurotransmitters. Biochem Eng J 2013. [DOI: 10.1016/j.bej.2013.04.019] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|
46
|
Ferreira NR, Santos RM, Laranjinha J, Barbosa RM. Real Time In Vivo Measurement of Ascorbate in the Brain Using Carbon Nanotube-Modified Microelectrodes. ELECTROANAL 2013. [DOI: 10.1002/elan.201300053] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
47
|
Kiyatkin EA, Wakabayashi KT, Lenoir M. Physiological fluctuations in brain temperature as a factor affecting electrochemical evaluations of extracellular glutamate and glucose in behavioral experiments. ACS Chem Neurosci 2013; 4:652-65. [PMID: 23448428 DOI: 10.1021/cn300232m] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
The rate of any chemical reaction or process occurring in the brain depends on temperature. While it is commonly believed that brain temperature is a stable, tightly regulated homeostatic parameter, it fluctuates within 1-4 °C following exposure to salient arousing stimuli and neuroactive drugs, and during different behaviors. These temperature fluctuations should affect neural activity and neural functions, but the extent of this influence on neurochemical measurements in brain tissue of freely moving animals remains unclear. In this Review, we present the results of amperometric evaluations of extracellular glutamate and glucose in awake, behaving rats and discuss how naturally occurring fluctuations in brain temperature affect these measurements. While this temperature contribution appears to be insignificant for glucose because its extracellular concentrations are large, it is a serious factor for electrochemical evaluations of glutamate, which is present in brain tissue at much lower levels, showing smaller phasic fluctuations. We further discuss experimental strategies for controlling the nonspecific chemical and physical contributions to electrochemical currents detected by enzyme-based biosensors to provide greater selectivity and reliability of neurochemical measurements in behaving animals.
Collapse
Affiliation(s)
- Eugene A. Kiyatkin
- In-Vivo Electrophysiology Unit, Behavioral Neuroscience
Branch, National Institute on Drug Abuse − Intramural Research
Program, National Institutes of Health,
DHHS, 333 Cassell Drive, Baltimore, Maryland 21224, United States
| | - Ken T. Wakabayashi
- In-Vivo Electrophysiology Unit, Behavioral Neuroscience
Branch, National Institute on Drug Abuse − Intramural Research
Program, National Institutes of Health,
DHHS, 333 Cassell Drive, Baltimore, Maryland 21224, United States
| | - Magalie Lenoir
- In-Vivo Electrophysiology Unit, Behavioral Neuroscience
Branch, National Institute on Drug Abuse − Intramural Research
Program, National Institutes of Health,
DHHS, 333 Cassell Drive, Baltimore, Maryland 21224, United States
| |
Collapse
|
48
|
Pereira C, Ferreira NR, Rocha BS, Barbosa RM, Laranjinha J. The redox interplay between nitrite and nitric oxide: From the gut to the brain. Redox Biol 2013; 1:276-84. [PMID: 24024161 PMCID: PMC3757698 DOI: 10.1016/j.redox.2013.04.004] [Citation(s) in RCA: 63] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2013] [Accepted: 04/09/2013] [Indexed: 02/09/2023] Open
Abstract
The reversible redox conversion of nitrite and nitric oxide ((•)NO) in a physiological setting is now widely accepted. Nitrite has long been identified as a stable intermediate of (•)NO oxidation but several lines of evidence support the reduction of nitrite to nitric oxide in vivo. In the gut, this notion implies that nitrate from dietary sources fuels the longstanding production of nitrite in the oral cavity followed by univalent reduction to (•)NO in the stomach. Once formed, (•)NO boosts a network of reactions, including the production of higher nitrogen oxides that may have a physiological impact via the post-translational modification of proteins and lipids. Dietary compounds, such as polyphenols, and different prandial states (secreting specific gastric mediators) modulate the outcome of these reactions. The gut has unusual characteristics that modulate nitrite and (•)NO redox interplay: (1) wide range of pH (neutral vs acidic) and oxygen tension (c.a. 70 Torr in the stomach and nearly anoxic in the colon), (2) variable lumen content and (3) highly developed enteric nervous system (sensitive to (•)NO and dietary compounds, such as glutamate). The redox interplay of nitrite and (•)NO might also participate in the regulation of brain homeostasis upon neuronal glutamatergic stimulation in a process facilitated by ascorbate and a localized and transient decrease of oxygen tension. In a way reminiscent of that occurring in the stomach, a nitrite/(•)NO/ascorbate redox interplay in the brain at glutamatergic synapses, contributing to local (•)NO increase, may impact on (•)NO-mediated process. We here discuss the implications of the redox conversion of nitrite to (•)NO in the gut, how nitrite-derived (•)NO may signal from the digestive to the central nervous system, influencing brain function, as well as a putative ascorbate-driven nitrite/NO pathway occurring in the brain.
Collapse
Affiliation(s)
- Cassilda Pereira
- Department of Pharmacy and Center for Neurosciences and Cell Biology, University of Coimbra, Health Sciences Campus, Azinhaga de Santa Comba, 3000-548 Coimbra, Portugal
| | | | | | | | | |
Collapse
|
49
|
Kealy J, Bennett R, Lowry JP. Simultaneous recording of hippocampal oxygen and glucose in real time using constant potential amperometry in the freely-moving rat. J Neurosci Methods 2013; 215:110-20. [PMID: 23499196 DOI: 10.1016/j.jneumeth.2013.02.016] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2012] [Revised: 01/31/2013] [Accepted: 02/22/2013] [Indexed: 01/02/2023]
Abstract
Amperometric sensors for oxygen and glucose allow for real time recording from the brain in freely-moving animals. These sensors have been used to detect activity- and drug-induced changes in metabolism in a number of brain regions but little attention has been given over to the hippocampus despite its importance in cognition and disease. Sensors for oxygen and glucose were co-implanted into the hippocampus and allowed to record for several days. Baseline recordings show that basal concentrations of hippocampal oxygen and glucose are 100.26±5.76 μM and 0.60±0.06 mM respectively. Furthermore, stress-induced changes in neural activity have been shown to significantly alter concentrations of both analytes in the hippocampus. Administration of O2 gas to the animals' snouts results in significant increases in hippocampal oxygen and glucose and administration of N2 gas results in a significant decrease in hippocampal oxygen. Chloral hydrate-induced anaesthesia causes a significant increase in hippocampal oxygen whereas treatment with the carbonic anhydrase inhibitor acetazolamide significantly increases hippocampal oxygen and glucose. These findings provide real time electrochemical data for the hippocampus which has been previously impossible with traditional methods such as microdialysis or ex vivo analysis. As such, these sensors provide a window into hippocampal function which can be used in conjunction with behavioural and pharmacological interventions to further elucidate the functions and mechanisms of action of the hippocampus in normal and disease states.
Collapse
Affiliation(s)
- John Kealy
- Department of Chemistry, National University of Ireland Maynooth, Maynooth, Co. Kildare, Ireland.
| | | | | |
Collapse
|
50
|
Vasylieva N, Maucler C, Meiller A, Viscogliosi H, Lieutaud T, Barbier D, Marinesco S. Immobilization Method to Preserve Enzyme Specificity in Biosensors: Consequences for Brain Glutamate Detection. Anal Chem 2013; 85:2507-15. [DOI: 10.1021/ac3035794] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Natalia Vasylieva
- University Claude Bernard Lyon 1, Lyon, F-69000, France
- Institut de Nanotechnologie
de Lyon, CNRS UMR-5270, INSA de Lyon, France
| | | | - Anne Meiller
- University Claude Bernard Lyon 1, Lyon, F-69000, France
| | - Henry Viscogliosi
- Service Central d’Analyse, CNRS UMR-5280−Echangeur de Solaize, Solaize,
FRANCE
| | | | - Daniel Barbier
- Institut de Nanotechnologie
de Lyon, CNRS UMR-5270, INSA de Lyon, France
| | | |
Collapse
|