1
|
Kwon YH, Park S, Jiang H, Gurudatt NG, Lee K, Jeong H, Nie C, Shin J, Hyun KA, Jung HI. High-resolution spiral microfluidic channel integrated electrochemical device for isolation and detection of extracellular vesicles without lipoprotein contamination. Biosens Bioelectron 2025; 267:116792. [PMID: 39307033 DOI: 10.1016/j.bios.2024.116792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 09/11/2024] [Accepted: 09/16/2024] [Indexed: 11/08/2024]
Abstract
Recent studies have indicated significant correlation between the concentration of immune checkpoint markers borne by extracellular vesicles (EVs) and the efficacy of immunotherapy. This study introduces a high-resolution spiral microfluidic channel-integrated electrochemical device (HiMEc), which is designed to isolate and detect EVs carrying the immune checkpoint markers programmed death ligand 1 (PD-L1) and programmed death protein 1 (PD-1), devoid of plasma-abundant lipoprotein contamination. Antigen-antibody reactions were applied to immobilize the lipoproteins on bead surfaces within the plasma, establishing a size differential with EVs. A plasma sample was then introduced into the spiral microfluidic channel, which facilitated the acquisition of nanometer-sized EVs and the elimination of micrometer-sized lipoprotein-bead complexes, along with the isolation and quantification of EVs using HiMEc. PD-L1 and PD-1 expression on EVs was evaluated in 30 plasma samples (10 from healthy donors, 20 from lung cancer patients) using HiMEc and compared to the results obtained from standard tissue-based PD-L1 testing, noting that HiMEc could be utilized to select further potential candidates. The obtained results are expected to contribute positively to the clinical assessment of potential immunotherapy beneficiaries.
Collapse
Affiliation(s)
- Yong-Hyun Kwon
- School of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Sunyoung Park
- School of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea; The DABOM Inc., Seoul, Republic of Korea
| | - Hairi Jiang
- School of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - N G Gurudatt
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, USA
| | - Kyungyeon Lee
- Department of Medical Engineering, College of Medicine, Yonsei University, Seoul, 03722, Republic of Korea
| | | | - Cheng Nie
- School of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Joonchul Shin
- School of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Kyung-A Hyun
- Korea Electronics Technology Institute (KETI), 25, Saenari-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 13509, Republic of Korea.
| | - Hyo-Il Jung
- School of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea; The DABOM Inc., Seoul, Republic of Korea.
| |
Collapse
|
2
|
Zheng K, Liu Z, Pang Y, Wang X, Zhao S, Zheng N, Cai F, Zhang C. Predictive Model for Cell Positioning during Periodic Lateral Migration in Spiral Microchannels. Anal Chem 2024. [PMID: 39436732 DOI: 10.1021/acs.analchem.4c04456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2024]
Abstract
The periodic lateral migration of submicrometer cells is the primary factor leading to low precision in a spiral microchannel during cell isolation. In this study, a mathematical predictive model (PM) is derived for the lateral position of cells during the periodic lateral migration process. We analyze the relationship of migration period, migration width, and starting point of lateral migration with microchannel structure and flow conditions and determine the empirical coefficients in PM. Results indicate that the aspect ratio of the microchannel and the Reynolds number (Re) are key factors that influence the periodicity of the cell lateral migration. The lateral migration width is jointly affected by Re, the cell blockage ratio, and the microchannel curvature radius. The inlet structure of the microchannel and the ratio of the cell sample to the sheath flow rate are critical parameters for regulating the initial position. Moreover, the structure of the pressure field at the inlet constrains the distribution range of the starting point of the lateral migration. Regardless of whether the particles/cells undergo 0.5, 1, or multiple lateral migration cycles, the lateral positions predicted by PM align well with the experimental observations, thus verifying the accuracy of PM. This research helps to elucidate the characteristics of periodic lateral migration of cells in spiral microchannels and can provide practical guidance for the development and optimization of miniature spiral microchannel chips for precise cell isolation.
Collapse
Affiliation(s)
- Kai Zheng
- College of Mechanical and Energy Engineering, Beijing University of Technology, Beijing 100124, China
| | - Zhaomiao Liu
- School of Mathematics, Statistics and Mechanics, Beijing University of Technology, Beijing 100124, China
| | - Yan Pang
- School of Mathematics, Statistics and Mechanics, Beijing University of Technology, Beijing 100124, China
| | - Xiang Wang
- School of Mathematics, Statistics and Mechanics, Beijing University of Technology, Beijing 100124, China
| | - Siyu Zhao
- School of Mathematics, Statistics and Mechanics, Beijing University of Technology, Beijing 100124, China
| | - Nan Zheng
- School of Mathematics, Statistics and Mechanics, Beijing University of Technology, Beijing 100124, China
| | - Fanming Cai
- School of Mathematics, Statistics and Mechanics, Beijing University of Technology, Beijing 100124, China
| | - Chenchen Zhang
- School of Mathematics, Statistics and Mechanics, Beijing University of Technology, Beijing 100124, China
| |
Collapse
|
3
|
Zhao T, Zeng P, Zhang Y, Li J, Sun H, Gablech I, Chang H, Yuan X, Neužil P, Feng J. Inertial co-focusing of heterogeneous particles in hybrid microfluidic channels with constantly variable cross-sections. LAB ON A CHIP 2024; 24:5032-5042. [PMID: 39344900 DOI: 10.1039/d4lc00479e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/01/2024]
Abstract
Heterogeneous particles co-focusing to a single stream is a vital prerequisite for cell counting and enumeration, playing an essential role in flow cytometry and single-cell analysis. Microfluidics-based inertial focusing holds great research prospects due to its simplicity of devices, ease of operation, high throughput, and freedom from external fields. Combining microfluidic channels with two or more different geometries has become a powerful tool for high-efficiency particle focusing. Here, we explored hybrid microfluidic channels for heterogeneous particle co-focusing. Four different annular channels with obstacles distributed on the inner wall were constructed and simulated, obtaining constantly variable secondary flows. Then we used four different fluorescent particles with the size of 10 μm, 12 μm 15 μm, and 20 μm as well as their mixture to perform the inertial focusing experiments of multi-sized particles. Theoretical simulation and experimental results demonstrated a focusing efficiency of >99%. Finally, we further utilized human white blood cells to estimate the co-focusing performance of our hybrid microfluidic channel, resulting in a high focusing efficiency of >92% and a high throughput of ≈8000 cell s-1. The hybrid microfluidic channels, capable of high-precision heterogeneous particle co-focusing, could pave a broad avenue for microfluidic flow cytometry and single-cell analysis.
Collapse
Affiliation(s)
- Tianwei Zhao
- School of Microelectronics, Hefei University of Technology, Hefei, 230601, China.
| | - Peng Zeng
- School of Microelectronics, Hefei University of Technology, Hefei, 230601, China.
| | - Yuanting Zhang
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an, 710072, China.
| | - Jinxia Li
- Department of Medical Laboratory, Xi'an International Medical Centre Hospital, Xi'an 710100, China
| | - Hui Sun
- Department of Medical Laboratory, Xi'an International Medical Centre Hospital, Xi'an 710100, China
| | - Imrich Gablech
- Department of Microelectronics, FEEC, Brno University of Technology, Technicka 10, CZ-616 00 Brno, Czech Republic
| | - Honglong Chang
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an, 710072, China.
| | - Xichen Yuan
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an, 710072, China.
| | - Pavel Neužil
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an, 710072, China.
| | - Jianguo Feng
- School of Microelectronics, Hefei University of Technology, Hefei, 230601, China.
| |
Collapse
|
4
|
Lee KCM, Chung BMF, Siu DMD, Ho SCK, Ng DKH, Tsia KK. Dispersion-free inertial focusing (DIF) for high-yield polydisperse micro-particle filtration and analysis. LAB ON A CHIP 2024; 24:4182-4197. [PMID: 39101363 DOI: 10.1039/d4lc00275j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/06/2024]
Abstract
Inertial focusing excels at the precise spatial ordering and separation of microparticles by size within fluid flows. However, this advantage, resulting from its inherent size-dependent dispersion, could turn into a drawback that challenges applications requiring consistent and uniform positioning of polydisperse particles, such as microfiltration and flow cytometry. To overcome this fundamental challenge, we introduce Dispersion-Free Inertial Focusing (DIF). This new method minimizes particle size-dependent dispersion while maintaining the high throughput and precision of standard inertial focusing, even in a highly polydisperse scenario. We demonstrate a rule-of-thumb principle to reinvent an inertial focusing system and achieve an efficient focusing of particles ranging from 6 to 30 μm in diameter onto a single plane with less than 3 μm variance and over 95% focusing efficiency at highly scalable throughput (2.4-30 mL h-1) - a stark contrast to existing technologies that struggle with polydispersity. We demonstrated that DIF could be applied in a broad range of applications, particularly enabling high-yield continuous microparticle filtration and large-scale high-resolution single-cell morphological analysis of heterogeneous cell populations. This new technique is also readily compatible with the existing inertial microfluidic design and thus could unleash more diverse systems and applications.
Collapse
Affiliation(s)
- Kelvin C M Lee
- The University of Hong Kong, Pokfulam Road, Hong Kong, Hong Kong.
- Advanced Biomedical Instrumentation Centre, Hong Kong Science Park, Shatin, New Territories, Hong Kong
| | - Bob M F Chung
- The University of Hong Kong, Pokfulam Road, Hong Kong, Hong Kong.
- Advanced Biomedical Instrumentation Centre, Hong Kong Science Park, Shatin, New Territories, Hong Kong
| | - Dickson M D Siu
- The University of Hong Kong, Pokfulam Road, Hong Kong, Hong Kong.
- Advanced Biomedical Instrumentation Centre, Hong Kong Science Park, Shatin, New Territories, Hong Kong
| | - Sam C K Ho
- The University of Hong Kong, Pokfulam Road, Hong Kong, Hong Kong.
| | - Daniel K H Ng
- The University of Hong Kong, Pokfulam Road, Hong Kong, Hong Kong.
| | - Kevin K Tsia
- The University of Hong Kong, Pokfulam Road, Hong Kong, Hong Kong.
- Advanced Biomedical Instrumentation Centre, Hong Kong Science Park, Shatin, New Territories, Hong Kong
| |
Collapse
|
5
|
Saito M, Arai F, Yamanishi Y, Sakuma S. Spatiotemporally controlled microvortices provide advanced microfluidic components. Proc Natl Acad Sci U S A 2024; 121:e2306182121. [PMID: 39102543 PMCID: PMC11331141 DOI: 10.1073/pnas.2306182121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Accepted: 06/27/2024] [Indexed: 08/07/2024] Open
Abstract
Microvortices are emerging components that impart functionality to microchannels by exploiting inertia effects such as high shear stress, effective fluid diffusion, and large pressure loss. Exploring the dynamic generation of vortices further expands the scope of microfluidic applications, including cell stimulation, fluid mixing, and transport. Despite the crucial role of vortices' development within sub-millisecond timescales, previous studies in microfluidics did not explore the modulation of the Reynolds number (Re) in the range of several hundred. In this study, we modulated high-speed flows (54 < [Formula: see text] < 456) within sub-millisecond timescales using a piezo-driven on-chip membrane pump. By applying this method to microchannels with asymmetric geometries, we successfully controlled the spatiotemporal development of vortices, adjusting their behavior in response to oscillatory flow directions. These different vortices induced different pressure losses, imparting the microchannels with direction-dependent flow resistance, mimicking a diode-like behavior. Through precise control of vortex development, we managed to regulate this direction-dependent resistance, enabling the rectification of oscillatory flow resembling a diode and the ability to switch its rectification direction. This component facilitated bidirectional flow control without the need for mechanical valves. Moreover, we demonstrated its application in microfluidic cell pipetting, enabling the isolation of single cells. Consequently, based on modulating high-speed flow, our approach offers precise control over the spatiotemporal development of vortices in microstructures, thereby introducing innovative microfluidic functionalities.
Collapse
Affiliation(s)
- Makoto Saito
- Department of Mechanical Engineering, Faculty of Engineering, Kyushu University, Fukuoka819-0395, Japan
| | - Fumihito Arai
- Department of Mechanical Engineering, Graduate School of Engineering, The University of Tokyo, Bunkyo-ku113-8656, Japan
| | - Yoko Yamanishi
- Department of Mechanical Engineering, Faculty of Engineering, Kyushu University, Fukuoka819-0395, Japan
| | - Shinya Sakuma
- Department of Mechanical Engineering, Faculty of Engineering, Kyushu University, Fukuoka819-0395, Japan
| |
Collapse
|
6
|
Zhang D, Bu J, Dou X, Yan Y, Liu Q, Wang X, Sun Z, Guo G, Zheng K, Deng J. Ultra-Large Two-Dimensional Metal Nanowire Networks by Microfluidic Laminar Flow Synthesis for Formic Acid Electrooxidation. Angew Chem Int Ed Engl 2024; 63:e202408765. [PMID: 38797705 DOI: 10.1002/anie.202408765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2024] [Revised: 05/22/2024] [Accepted: 05/24/2024] [Indexed: 05/29/2024]
Abstract
Despite the great research interest in two-dimensional metal nanowire networks (2D MNWNs) due to their large specific surface area and abundance of unsaturated coordination atoms, their controllable synthesis still remains a significant challenge. Herein, a microfluidics laminar flow-based approach is developed, enabling the facile preparation of large-scale 2D structures with diverse alloy compositions, such as PtBi, AuBi, PdBi, PtPdBi, and PtAuCu alloys. Remarkably, these 2D MNWNs can reach sizes up to submillimeter scale (~220 μm), which is significantly larger than the evolution from the 1D or 3D counterparts that typically measure only tens of nanometers. The PdBi 2D MNWNs affords the highest specific activity for formic acid (2669.1 mA mg-1) among current unsupported catalysts, which is 103.5 times higher than Pt-black, respectively. Furthermore, in situ Fourier transform infrared (FTIR) experiments provide comprehensive evidence that PdBi 2D MNWNs catalysts can effectively prevent CO* poisoning, resulting in exceptional activity and stability for the oxidation of formic acid.
Collapse
Affiliation(s)
- Dongtang Zhang
- Key Laboratory of Beijing on Regional Air Pollution Control, Beijing Key Laboratory for Green Catalysis and Separation, Beijing University of Technology, Beijing, 100124, PR China
| | - Jiahui Bu
- Center of Excellence for Environmental Safety and Biological Effects, Department of Chemistry, Beijing University of Technology, Beijing, 100124, PR China
| | - Xiangnan Dou
- Center of Excellence for Environmental Safety and Biological Effects, Department of Chemistry, Beijing University of Technology, Beijing, 100124, PR China
| | - Yong Yan
- Center of Excellence for Environmental Safety and Biological Effects, Department of Chemistry, Beijing University of Technology, Beijing, 100124, PR China
| | - Qiqi Liu
- Center of Excellence for Environmental Safety and Biological Effects, Department of Chemistry, Beijing University of Technology, Beijing, 100124, PR China
| | - Xiayan Wang
- Center of Excellence for Environmental Safety and Biological Effects, Department of Chemistry, Beijing University of Technology, Beijing, 100124, PR China
| | - Zaicheng Sun
- Center of Excellence for Environmental Safety and Biological Effects, Department of Chemistry, Beijing University of Technology, Beijing, 100124, PR China
| | - Guangsheng Guo
- Center of Excellence for Environmental Safety and Biological Effects, Department of Chemistry, Beijing University of Technology, Beijing, 100124, PR China
| | - Kun Zheng
- Beijing Key Laboratory of Microstructure and Properties of Solids, Beijing University of Technology, Beijing, 100124, PR China
| | - Jiguang Deng
- Key Laboratory of Beijing on Regional Air Pollution Control, Beijing Key Laboratory for Green Catalysis and Separation, Beijing University of Technology, Beijing, 100124, PR China
| |
Collapse
|
7
|
Chen D, Huang Q, Ni Z, Xiang N. Particle focusing mechanisms in λ-DNA solution flowing in a straight microchannel. Electrophoresis 2024; 45:1379-1388. [PMID: 38343171 DOI: 10.1002/elps.202300295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 01/27/2024] [Accepted: 02/03/2024] [Indexed: 08/22/2024]
Abstract
Most biological fluids (such as blood, saliva, and lymph) in nature have certain viscoelasticity and are beginning to be used as the carrying fluids for viscoelastic microfluidics. However, the particle-focusing mechanisms in these new biological viscoelastic fluids are still unclear. In this work, the particle-focusing mechanisms in λ-DNA solutions were systematically explored. We first explored the particle focusing dynamics in a square cross-section under varied flow rates to uncover the effects of flow rate on particle focusing. Three focusing stages, from the classic five-position viscoelastic focusing to single-stream focusing and finally to multiplex-stream focusing, were clearly demonstrated. In addition, the particle focusing process along the channel length was demonstrated, and a first-fast-and-then-slow focusing process was clearly observed. Then, the effects of λ-DNA concentrations on particle focusing were explored and compared using the solutions with 0-25 ppm λ-DNA. Finally, we discussed the inferences of blockage ratio on particle focusing by changing the particle diameter and cross-sectional dimensions. Our work may provide a deeper understanding on the particle focusing mechanisms in biological viscoelastic fluids and lays a foundation for the subsequent particle counting and analysis and the development of low-cost portable flow cytometers.
Collapse
Affiliation(s)
- Dalin Chen
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Qiang Huang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Zhonghua Ni
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Nan Xiang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| |
Collapse
|
8
|
Shen S, Liu X, Fan K, Bai H, Li X, Li H. Stabilizing and Accelerating Secondary Flow in Ultralong Spiral Channel for High-Throughput Cell Manipulation. Anal Chem 2024; 96:11412-11421. [PMID: 38954777 DOI: 10.1021/acs.analchem.4c01549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/04/2024]
Abstract
Efficient cell manipulation is essential for numerous applications in bioanalysis and medical diagnosis. However, the lack of stability and strength in the secondary flow, coupled with the narrow range of practical throughput, severely restricts the diverse applications. Herein, we present an innovative inertial microfluidic device that employs a spiral channel for high-throughput cell manipulation. Our investigation demonstrates that the regulation of Dean-like secondary flow in the microchannel can be achieved through geometric confinement. Introducing ordered microstructures into the ultralong spiral channel (>90 cm) stabilizes and accelerates the secondary flow among different loops. Consequently, effective manipulation of blood cells within a wide cell throughput range (1.73 × 108 to 1.16 × 109 cells/min) and cancer cells across a broad throughput range (0.5 × 106 to 5 × 107 cells/min) can be achieved. In comparison to previously reported technologies, our engineering approach of stabilizing and accelerating secondary flow offers specific performance for cell manipulation under a wide range of high-throughput manner. This engineered spiral channel would be promising in biomedical analysis, especially when cells need to be focused efficiently on large-volume liquid samples.
Collapse
Affiliation(s)
- Shaofei Shen
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taiyuan, Shanxi 030000, P. R. China
| | - Xufang Liu
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taiyuan, Shanxi 030000, P. R. China
| | - Kuohai Fan
- Shanxi Key Lab for Modernization of TCVM, College of Veterinary Medicine, Shanxi Agricultural University, Taiyuan, Shanxi 030000, P. R. China
| | - Hanjie Bai
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taiyuan, Shanxi 030000, P. R. China
| | - Xiaoping Li
- Department of Breast, Jiangmen Central Hospital, Jiangmen, Guangdong 529000, P. R. China
| | - Hongquan Li
- Shanxi Key Lab for Modernization of TCVM, College of Veterinary Medicine, Shanxi Agricultural University, Taiyuan, Shanxi 030000, P. R. China
| |
Collapse
|
9
|
Ahasan K, Schnoebelen NJ, Shrotriya P, Kingston TA. Continuous Sampling of Aerosolized Particles Using Stratified Two-Phase Microfluidics. ACS Sens 2024; 9:2915-2924. [PMID: 38848499 DOI: 10.1021/acssensors.4c00042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2024]
Abstract
Health and security concerns have made it essential to develop integrated, continuous collection and sensing platforms that are compact and capable of real-time detection. In this study, we numerically investigate the flow physics associated with the single-step collection and enrichment of aerosolized polystyrene microparticles into a flowing liquid using a stratified air-water flow in a U-shaped microchannel. We validate our simulation results by comparing them to experimental data from the literature. Additionally, we fabricate an identical microfluidic device using PDMS-based soft lithography and test it to corroborate the previously published experimental data. Diversion and entrapment efficiencies are used as evaluation metrics, both of which increase with increasing particle diameter and superficial air inlet velocity. Overall, our ANSYS Fluent two-dimensional (2D) and three-dimensional (3D) multiphase flow simulations exhibit a good agreement with our experimental data and data in the literature (average deviation of ∼11%) in terms of diversion efficiency. Simulations also found the entrapment efficiency to be lower than the diversion efficiency, indicating discrepancies in the literature in terms of captured particles. The effect of the Dean force on the flow physics was also investigated using 3D simulations. We found that the effect of the Dean flow was more dominant relative to the centrifugal force on the smaller particles (e.g., 0.65 μm) compared to the larger particles (e.g., 2.1 μm). Increasing the superficial air inlet velocity also increases the effect of the centrifugal forces relative to the Dean forces. Overall, this experimentally validated multiphase model decouples and investigates the multiple and simultaneous forces on aerosolized particles flowing through a curved microchannel, which is crucial for designing more efficient capture devices. Once integrated with a microfluidic-based biosensor, this stratified flow-based microfluidic biothreat capture platform should deliver continuous sensor-ready enriched biosamples for real-time sensing.
Collapse
Affiliation(s)
- Kawkab Ahasan
- Center for Multiphase Flow Research and Education, Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Nicholas J Schnoebelen
- Center for Multiphase Flow Research and Education, Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Pranav Shrotriya
- Center for Multiphase Flow Research and Education, Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Todd A Kingston
- Center for Multiphase Flow Research and Education, Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, United States
| |
Collapse
|
10
|
Hu X, Yu L, Zhu Z, Bao F, Lin J, Tu C, Lin P. A self-cleaning micro-fluidic chip biospired by the filtering system of manta rays. LAB ON A CHIP 2024; 24:3064-3079. [PMID: 38757493 DOI: 10.1039/d4lc00039k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2024]
Abstract
Size-based particle filtration has become indispensable in numerous biomedical and environmental applications. In this study, bioinspired by the filter-feeding mechanism (lobe filtration) of manta rays, we designed a U-shaped biomimetic gill rake filter that combined lobe filtration and Dean flow to filter monodisperse suspensions, bi-disperse suspensions and yeast cells. Compared with other equipment using the inertial focusing technology, our equipment can perform high-throughput (up to 8 mL min-1) and high-efficiency filtration of particles (maximum filtration efficiencies of 96.08% and 97.14% for 10 and 15 μm monodisperse suspensions at the optimum flow rate of 6 mL min-1). The complex velocity field of the micro-fluidic flow within the filter is numerically simulated, and in combination with experiments, a threshold for the flow rate is identified. When the inlet flow rate exceeds the threshold value, the efficiency of particle filtration is increased rapidly. Afterwards, by analysing the filtration mechanism, we develop three novel filtration processes. The equilibrium positions of the particles and yeast cells in the main channel are close to the outer wall at high flow rate, which diminishes the likelihood of particles and yeast cells entering the side channel. This configuration establishes a self-cleaning mechanism, ensuring prolonged and efficient operation of the filter with high-throughput processing. Furthermore, the influence of the filter lobe angle and channel width on the filtration efficiency and outlet flow rate ratio are explored, and an optimisation plan is prepared.
Collapse
Affiliation(s)
- Xiao Hu
- Zhejiang Key Laboratory of Multiflow and Fluid Machinery, Zhejiang Sci-Tech University, Hangzhou, Zhejiang 310018, PR China.
| | - Longfei Yu
- Zhejiang Key Laboratory of Multiflow and Fluid Machinery, Zhejiang Sci-Tech University, Hangzhou, Zhejiang 310018, PR China.
| | - Zuchao Zhu
- Zhejiang Key Laboratory of Multiflow and Fluid Machinery, Zhejiang Sci-Tech University, Hangzhou, Zhejiang 310018, PR China.
| | - Fubing Bao
- Zhejiang Provincial Key Laboratory of Flow Measurement Technology, China Jiliang University, Hangzhou, Zhejiang 310027, PR China.
| | - Jianzhong Lin
- Zhejiang Provincial Engineering Research Center for the Safety of Pressure Vessels and Pipelines, Ningbo University, Ningbo, Zhejiang 315211, PR China
| | - Chengxu Tu
- Zhejiang Provincial Key Laboratory of Flow Measurement Technology, China Jiliang University, Hangzhou, Zhejiang 310027, PR China.
| | - Peifeng Lin
- Zhejiang Key Laboratory of Multiflow and Fluid Machinery, Zhejiang Sci-Tech University, Hangzhou, Zhejiang 310018, PR China.
| |
Collapse
|
11
|
Shi X, He Q, Tan W, Lu Y, Zhu G. Experiment study on focusing pattern prediction of particles in asymmetric contraction-expansion array channel. Electrophoresis 2024. [PMID: 38794969 DOI: 10.1002/elps.202400042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 04/29/2024] [Accepted: 05/02/2024] [Indexed: 05/27/2024]
Abstract
Contraction-expansion array (CEA) microchannel is a typical structure applied on particle/cell manipulation. The prediction of the particle focusing pattern in CEA microchannel is worthwhile to be investigate deeply. Here, we demonstrated a virtual boundary method by flow field analysis and theoretical derivation. The calculating method of the virtual boundary location, related to the Reynolds number (Re) and the structure parameter RW, was proposed. Combining the approximate Poiseuille flow pattern based on the virtual boundary method with the simulation results of Dean flow, the main line pattern and the main/lateral lines pattern were predicted and validated in experiments. The transformation from the main line pattern to the main/lateral lines pattern can be facilitated by increasing Re, decreasing RW , and decreasing α. An empirical formula was derived to characterize the critical condition of the transformation. The virtual boundary method can provide a guidance for asymmetric CEA channel design and contribute to the widespread application of microfluidic particle focusing.
Collapse
Affiliation(s)
- Xin Shi
- School of Chemical Engineering and Technology, Tianjin University, Tianjin, P. R. China
| | | | - Wei Tan
- School of Chemical Engineering and Technology, Tianjin University, Tianjin, P. R. China
| | - Yuwen Lu
- School of Chemical Engineering and Technology, Tianjin University, Tianjin, P. R. China
- Haihe Laboratory of Sustainable Chemical Transformations, Tianjin, P. R. China
| | - Guorui Zhu
- School of Chemical Engineering and Technology, Tianjin University, Tianjin, P. R. China
- Haihe Laboratory of Sustainable Chemical Transformations, Tianjin, P. R. China
| |
Collapse
|
12
|
Sahin MA, Shehzad M, Destgeer G. Stopping Microfluidic Flow. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2307956. [PMID: 38143295 DOI: 10.1002/smll.202307956] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Revised: 11/13/2023] [Indexed: 12/26/2023]
Abstract
A cross-comparison of three stop-flow configurations-such as low-pressure (LSF), high-pressure open-circuit (OC-HSF), and high-pressure short-circuit (SC-HSF) stop-flow-is presented to rapidly bring a high velocity flow O(m s-1) within a microchannel to a standstill O(µm s-1). The performance of three stop-flow configurations is assessed by measuring residual flow velocities within microchannels having three orders of magnitude different flow resistances. The LSF configuration outperforms the OC-HSF and SC-HSF configurations within a high flow resistance microchannel and results in a residual velocity of <10 µm s-1. The OC-HSF configuration results in a residual velocity of <150 µm s-1 within a low flow resistance microchannel. The SC-HSF configuration results in a residual velocity of <200 µm s-1 across the three orders-of-magnitude different flow resistance microchannels, and <100 µm s-1 for the low flow resistance channel. It is hypothesized that residual velocity results from compliance in fluidic circuits, which is further investigated by varying the elasticity of microchannel walls and connecting tubing. A numerical model is developed to estimate the expanded volumes of the compliant microchannel and connecting tubings under a pressure gradient and to calculate the distance traveled by the sample fluid. A comparison of the numerically and experimentally obtained traveling distances confirms the hypothesis that the residual velocities are an outcome of the compliance in the fluidic circuit.
Collapse
Affiliation(s)
- Mehmet Akif Sahin
- Control and Manipulation of Microscale Living Objects, Department of Electrical Engineering, School of Computation, Information and Technology (CIT), Center for Translational Cancer Research (TranslaTUM), Technical University of Munich, Einsteinstraße 25, 81675, Munich, Germany
| | - Muhammad Shehzad
- Control and Manipulation of Microscale Living Objects, Department of Electrical Engineering, School of Computation, Information and Technology (CIT), Center for Translational Cancer Research (TranslaTUM), Technical University of Munich, Einsteinstraße 25, 81675, Munich, Germany
| | - Ghulam Destgeer
- Control and Manipulation of Microscale Living Objects, Department of Electrical Engineering, School of Computation, Information and Technology (CIT), Center for Translational Cancer Research (TranslaTUM), Technical University of Munich, Einsteinstraße 25, 81675, Munich, Germany
| |
Collapse
|
13
|
Dong H, Huang L, Zhao L. Influence of the internal structure of straight microchannels on inertial transport behavior of particles. Heliyon 2024; 10:e29577. [PMID: 38655341 PMCID: PMC11036054 DOI: 10.1016/j.heliyon.2024.e29577] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2023] [Revised: 04/09/2024] [Accepted: 04/10/2024] [Indexed: 04/26/2024] Open
Abstract
The rapid advancement of Micro-Electro-Mechanical Systems (MEMS) technology has established microfluidics as a pivotal field. This technology marks the onset of a new era in various applications, including drug testing, cell culture, and disease monitoring, underscoring its extensive practicality and potential for future exploration. This research delves into the intricate behavior of particle inertial migration within microchannels, particularly focusing on the impact of different channel structures and Reynolds numbers (Re). Our studies reveal that particles in microchannels with one-sided sharp-cornered microstructures migrate towards the sharp corner at a relative position of 0.4 under low flow rates, and towards the straight wall side at a relative position of 0.8 under high flow rates. The migration pattern of equilibrium positions varies with different arrangements of sharp-corner structures, achieving stability at the channel's center only when the sharp corners are symmetrically arranged on both sides. Our investigation into the shape of microstructures indicates that sharp-cornered structures generate a more stable secondary flow compared to rectangular and semi-circular structures, preventing particle aggregation at the outlet. To address the challenges associated with handling variable cross-section geometries and solid-wall boundaries in dissipative particle dynamics methods effectively, we have developed a dissipative particle dynamics model specifically for analyzing such microchannels. Building upon our previous research, this model introduces a conservative force coefficient for particles within the microstructured region and an interaction zone that only involves repulsive forces, aligning well with experimental outcomes. Through the study of microstructures' geometric shapes, this paper offers guidance for designing microchannels for particle enrichment. Furthermore, the dissipative particle dynamics model established for the particle flow and solid structure interaction within microstructured channels provides insights into the mesoscale dynamics of liquid-solid two-phase flow and particle motion. In conclusion, this paper aims to enhance particle motion sample preparation techniques, thereby broadening the scope of microfluidic applications in the biomedical field.
Collapse
Affiliation(s)
- Hua Dong
- State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, Xi'an, 710049, PR China
| | - Longrun Huang
- School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710049, PR China
| | - Liang Zhao
- State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, Xi'an, 710049, PR China
| |
Collapse
|
14
|
Chavez-Pineda OG, Rodriguez-Moncayo R, Gonzalez-Suarez AM, Guevara-Pantoja PE, Maravillas-Montero JL, Garcia-Cordero JL. Portable platform for leukocyte extraction from blood using sheath-free microfluidic DLD. LAB ON A CHIP 2024; 24:2575-2589. [PMID: 38646820 DOI: 10.1039/d4lc00132j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/23/2024]
Abstract
Leukocyte count is routinely performed for diagnostic purposes and is rapidly emerging as a significant biomarker for a wide array of diseases. Additionally, leukocytes have demonstrated considerable promise in novel cell-based immunotherapies. However, the direct retrieval of leukocytes from whole blood is a significant challenge due to their low abundance compared to erythrocytes. Here, we introduce a microfluidic-based platform that isolates and recovers leukocytes from diluted whole blood in a single step. Our platform utilizes a novel, sheathless method to initially sediment and focus blood cells into a dense stream while flowing through a tubing before entering the microfluidic device. A hexagonal-shaped structure, patterned at the device's inlet, directs all the blood cells against the channel's outer walls. The focused cells are then separated based on their size using the deterministic lateral displacement (DLD) microfluidic technique. We evaluated various parameters that could influence leukocyte separation, including different focusing structures (assessed both computationally and experimentally), the orientation of the tubing-chip interface, the effects of blood sample hematocrit (dilution), and flow rate. Our device demonstrated the ability to isolate leukocytes from diluted blood with a separation efficiency of 100%, a recovery rate of 76%, and a purity of 80%, while maintaining a cell viability of 98%. The device operates for over 30 min at a flow rate of 2 μL min-1. Furthermore, we developed a handheld pressure controller to drive fluid flow, enhancing the operability of our platform outside of central laboratories and enabling near-patient testing. Our platform can be integrated with downstream cell-based assays and analytical methods that require high leukocyte purity (80%), ranging from cell counting to diagnostics and cell culture applications.
Collapse
Affiliation(s)
- Oriana G Chavez-Pineda
- Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
| | - Roberto Rodriguez-Moncayo
- Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
| | - Alan M Gonzalez-Suarez
- Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
| | - Pablo E Guevara-Pantoja
- Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
| | - Jose L Maravillas-Montero
- Red de Apoyo a la Investigación, Universidad Nacional Autónoma de México e Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City14080, Mexico
| | - Jose L Garcia-Cordero
- Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
- Institute of Human Biology (IHB), Roche Pharma Research and Early Development, Roche Innovation Center Basel, Basel 4058, Switzerland.
| |
Collapse
|
15
|
Lesniewska M, Mottram N, Henrich O. Defect-influenced particle advection in highly confined liquid crystal flows. SOFT MATTER 2024; 20:2218-2231. [PMID: 38227288 DOI: 10.1039/d3sm01297b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/17/2024]
Abstract
We study the morphology of the Saturn ring defect and director structure around a colloidal particle with normal anchoring conditions and within the flow of the nematic host phase through a rectangular duct of comparable size to the particle. The changes in the defect structures and director profile influence the advection behaviour of the particle, which we compare to that in a simple Newtonian host phase. These effects lead to a non-monotonous dependence of the differential velocity of particle and fluid, also known as retardation ratio, on the Ericksen number.
Collapse
Affiliation(s)
| | - Nigel Mottram
- School of Mathematics & Statistics, University of Glasgow, Glasgow G12 8QQ, UK
| | - Oliver Henrich
- Department of Physics, University of Strathclyde, Glasgow G4 0NG, UK.
| |
Collapse
|
16
|
Shi Q, Wu J, Chen H, Xu X, Yang YB, Ding M. Inertial migration of polymer micelles in a square microchannel. SOFT MATTER 2024; 20:1760-1766. [PMID: 38295375 DOI: 10.1039/d3sm01304a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2024]
Abstract
Using a hybrid simulation approach that combines a lattice-Boltzmann method for fluid flow and a molecular dynamics model for polymers, we investigate the inertial migration of star-like and crew-cut polymer micelles in a square microchannel. It is found that they exhibit two types of equilibrium positions, which shift further away from the center of the microchannel when the Reynolds number (Re) increases, as can be observed for soft particles. What differs from the behaviors of soft particles is that here, the blockage ratio is no longer the decisive factor. When the sizes are the same, the star-like micelles are always relatively closer to the microchannel wall as they gradually transition from spherical to disc-like with the increase of Re. In comparison, the crew-cut micelles are only transformed into an ellipsoid. Conversely, when the hydrophobic core sizes are the same, the equilibrium position of the star-like micelles becomes closer to that of the crew-cut micelles. Our results demonstrate that for polymer micelles with a core-shell structure, the equilibrium position is no longer solely determined by their overall dimensions but depends on the core and shell's specific dimensions, especially the hydrophobic core size. This finding opens up a new approach for achieving the separation of micelles in inertial migration.
Collapse
Affiliation(s)
- Qingfeng Shi
- School of Chemical Engineering and Light Industry, Guangdong University of Technology, Guangzhou 510006, China.
| | - Jintang Wu
- School of Chemical Engineering and Light Industry, Guangdong University of Technology, Guangzhou 510006, China.
| | - Haisong Chen
- School of Chemical Engineering and Light Industry, Guangdong University of Technology, Guangzhou 510006, China.
| | - Xiaolong Xu
- School of Environmental and Chemical Engineering, Institute of Carbon Peaking and Carbon Neutralization, Wuyi University, Jiangmen 529020, China
| | - Yong-Biao Yang
- School of Chemistry and Chemical Engineering, Liaoning Normal University, Dalian 116029, China
| | - Mingming Ding
- School of Chemical Engineering and Light Industry, Guangdong University of Technology, Guangzhou 510006, China.
- Jieyang Branch of Chemistry and Chemical Engineering Guangdong Laboratory, Jieyang 515200, China
| |
Collapse
|
17
|
Anand P, Subramanian G. Inertial Migration in a Pressure-Driven Channel Flow: Beyond the Segre-Silberberg Pinch. PHYSICAL REVIEW LETTERS 2024; 132:054002. [PMID: 38364167 DOI: 10.1103/physrevlett.132.054002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 09/15/2023] [Accepted: 01/02/2024] [Indexed: 02/18/2024]
Abstract
We examine theoretically the inertial migration of a neutrally buoyant rigid sphere in pressure-driven channel flow, accounting for its finite size relative to the channel width (the confinement ratio). For sufficiently large channel Reynolds numbers (Re_{c}), a small but finite confinement ratio qualitatively alters the inertial lift velocity profiles obtained using a point-particle formulation. Finite size effects lead to new equilibria, in addition to the well-known Segre-Silberberg pinch locations. Consequently, a sphere can migrate to either the near-wall Segre-Silberberg equilibria, or the new stable equilibria located closer to the channel centerline, depending on Re_{c} and its initial position. Our findings are in accord with recent experiments and simulations, and have implications for passive sorting of particles based on size, shape, and other physical characteristics, in microfluidic applications.
Collapse
Affiliation(s)
- Prateek Anand
- International Centre for Theoretical Sciences, Bengaluru-560089, India
| | - Ganesh Subramanian
- Jawaharlal Nehru Centre for Advanced Scientific Research, Bengaluru-560064, India
| |
Collapse
|
18
|
Ashkani A, Jafari A, Ghomsheh MJ, Dumas N, Funfschilling D. Enhancing particle focusing: a comparative experimental study of modified square wave and square wave microchannels in lift and Dean vortex regimes. Sci Rep 2024; 14:2679. [PMID: 38302543 PMCID: PMC10834497 DOI: 10.1038/s41598-024-52839-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2023] [Accepted: 01/24/2024] [Indexed: 02/03/2024] Open
Abstract
Serpentine microchannels are known for their effective particle focusing through Dean flow-induced rotational effects, which are used in compact designs for size-dependent focusing in medical diagnostics. This study explores square serpentine microchannels, a geometry that has recently gained prominence in inertial microfluidics, and presents a modification of square wave microchannels for improved particle separation and focusing. The proposed modification incorporates an additional U-shaped unit to convert the square wave microchannel into a non-axisymmetric structure, which enhances the Dean flow and consequently increases the Dean drag force. Extensive experiments were conducted covering a wide range of Reynolds numbers and particle sizes (2.45 µm to 12 µm). The particle concentration capability and streak position dynamics of the two structures were compared in detail. The results indicate that the modified square-wave microchannel exhibits efficient particle separation in the lower part of the Dean vortex-dominated regime. With increasing Reynolds number, the particles are successively focused into two streaks in the lift force-dominated regime and into a single streak in the Dean vortex-dominated regime, in this modified square wave geometry. These streaks have a low standard deviation around a mean value. In the Dean vortex-dominated regime, the location of the particle stream is highly dependent on the particle size, which allows good particle separation. Particle focusing occurs at lower Reynolds numbers in both the lift-dominated and lift/Dean drag-dominated regions than in the square wave microchannel. The innovative serpentine channel is particularly useful for the Dean drag-dominated regime and introduces a unique asymmetry that affects the particle focusing dynamics. The proposed device offers significant advantages in terms of efficiency, parallelization, footprint, and throughput over existing geometries.
Collapse
Affiliation(s)
- Ali Ashkani
- School of Mechanical Engineering, Faculty of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran
| | - Azadeh Jafari
- School of Mechanical Engineering, Faculty of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran.
- ICube, UMR 7357-CNRS-Université de Strasbourg, 1, Cours des Cigarières, 67000, Strasbourg, France.
| | - Mehryar Jannesari Ghomsheh
- School of Mechanical Engineering, Faculty of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran
- Robert Frederick Smith School of Chemical and Biomolecular Engineering, Cornell University, Ithaca, NY, 14853, USA
| | - Norbert Dumas
- ICube, UMR 7357-CNRS-Université de Strasbourg, 1, Cours des Cigarières, 67000, Strasbourg, France
- ICube, UMR 7357-CNRS-Université de Strasbourg, 300 bd Sébastien Brant, 67412, Illkirch, France
| | - Denis Funfschilling
- ICube, UMR 7357-CNRS-Université de Strasbourg, 1, Cours des Cigarières, 67000, Strasbourg, France.
| |
Collapse
|
19
|
Shen S, Zhao L, Bai H, Zhang Y, Niu Y, Tian C, Chan H. Spiral Large-Dimension Microfluidic Channel for Flow-Rate- and Particle-Size-Insensitive Focusing by the Stabilization and Acceleration of Secondary Flow. Anal Chem 2024; 96:1750-1758. [PMID: 38215439 DOI: 10.1021/acs.analchem.3c04897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2024]
Abstract
Inertial microfluidics has demonstrated its ability to focus particles in a passive and straightforward manner. However, achieving flow-rate- and particle-size-insensitive focusing in large-dimension channels with a simple design remains challenging. In this study, we developed a spiral microfluidic with a large-dimension channel to achieve inertial focusing. By designing a unique "big buffering area" and a "small buffering area" in the spiral microchannel, we observed the stabilization and acceleration of secondary flow. Our optimized design allowed for efficient (>99.9%) focusing of 15 μm particles within a wide range of flow rates (0.5-4.5 mL/min) during a long operation duration (0-60 min). Additionally, we achieved effective (>95%) focusing of different-sized particles (7, 10, 15, and 30 μm) and three types of tumor cells (K562, HeLa, and MCF-7) near the inner wall of the 1 mm wide outlet when applying different flow rates (1-3 mL/min). Finally, successful 3D cell focusing was achieved within an optimized device, with the cells positioned at a distance of 50 μm from the wall. Our strategy of stabilizing and accelerating Dean-like secondary flow through the unique configuration of a "big buffering area" and a "small buffering area" proved to be highly effective in achieving inertial focusing that is insensitive to the flow rate and particle size, particularly in large-dimension channels. Consequently, it shows great potential for use in hand-operated microfluidic tools for flow cytometry.
Collapse
Affiliation(s)
- Shaofei Shen
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taiyuan 030000, Shanxi, P. R. China
| | - Lei Zhao
- School of Life Science and Technology, Xidian University, Xi'an 710126, Shaanxi, P. R. China
| | - Hanjie Bai
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taiyuan 030000, Shanxi, P. R. China
| | - Yali Zhang
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taiyuan 030000, Shanxi, P. R. China
| | - Yanbing Niu
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taiyuan 030000, Shanxi, P. R. China
| | - Chang Tian
- School of Medicine, Anhui University of Science and Technology, Huainan 232001, Anhui, P. R. China
| | - Henryk Chan
- Department of Automatic Control and Systems Engineering, The University of Sheffield, Sheffield S10 2TN, U.K
| |
Collapse
|
20
|
Shen Y, Gwak H, Han B. Advanced manufacturing of nanoparticle formulations of drugs and biologics using microfluidics. Analyst 2024; 149:614-637. [PMID: 38083968 PMCID: PMC10842755 DOI: 10.1039/d3an01739g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2024]
Abstract
Numerous innovative nanoparticle formulations of drugs and biologics, named nano-formulations, have been developed in the last two decades. However, methods for their scaled-up production are still lagging, as the amount needed for large animal tests and clinical trials is typically orders of magnitude larger. This manufacturing challenge poses a critical barrier to successfully translating various nano-formulations. This review focuses on how microfluidics technology has become a powerful tool to overcome this challenge by synthesizing various nano-formulations with improved particle properties and product purity in large quantities. This microfluidic-based manufacturing is enabled by microfluidic mixing, which is capable of the precise and continuous control of the synthesis of nano-formulations. We further discuss the specific applications of hydrodynamic flow focusing, a staggered herringbone micromixer, a T-junction mixer, a micro-droplet generator, and a glass capillary on various types of nano-formulations of polymeric, lipid, inorganic, and nanocrystals. Various separation and purification microfluidic methods to enhance the product purity are reviewed, including acoustofluidics, hydrodynamics, and dielectrophoresis. We further discuss the challenges of microfluidics being used by broader research and industrial communities. We also provide future outlooks of its enormous potential as a decentralized approach for manufacturing nano-formulations.
Collapse
Affiliation(s)
- Yingnan Shen
- School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA.
| | - Hogyeong Gwak
- School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA.
| | - Bumsoo Han
- School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA.
- Purdue University Institute for Cancer Research, West Lafayette, IN, 47907, USA
| |
Collapse
|
21
|
Jeon H, Lee SH, Shin J, Song K, Ahn N, Park J. Elasto-inertial microfluidic separation of microspheres with submicron resolution at high-throughput. MICROSYSTEMS & NANOENGINEERING 2024; 10:15. [PMID: 38264707 PMCID: PMC10803301 DOI: 10.1038/s41378-023-00633-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 10/23/2023] [Accepted: 11/08/2023] [Indexed: 01/25/2024]
Abstract
Elasto-inertial microfluidic separation offers many advantages including high throughput and separation resolution. Even though the separation efficiency highly depends on precise control of the flow conditions, no concrete guidelines have been reported yet in elasto-inertial microfluidics. Here, we propose a dimensionless analysis for precise estimation of the microsphere behaviors across the interface of Newtonian and viscoelastic fluids. Reynolds number, modified Weissenberg number, and modified elastic number are used to investigate the balance between inertial and elastic lift forces. Based on the findings, we introduce a new dimensionless number defined as the width of the Newtonian fluid stream divided by microsphere diameter. The proposed dimensionless analysis allows us to predict whether the microspheres migrate across the co-flow interface. The theoretical estimation is found to be in good agreement with the experimental results using 2.1- and 3.2-μm-diameter polystyrene microspheres in a co-flow of water and polyethylene oxide solution. Based on the theoretical estimation, we also realize submicron separation of the microspheres with 2.1 and 2.5 μm in diameter at high throughput, high purity (>95%), and high recovery rate (>97%). The applicability of the proposed method was validated by separation of platelets from similar-sized Escherichia coli (E.coli).
Collapse
Affiliation(s)
- Hyunwoo Jeon
- Department of Mechanical Engineering, Chonnam National University, 77 Yongbong-ro Buk-gu, Gwangju, 61186 Republic of Korea
| | - Song Ha Lee
- Department of Mechanical Engineering, Chonnam National University, 77 Yongbong-ro Buk-gu, Gwangju, 61186 Republic of Korea
| | - Jongho Shin
- Analytical Engineering Team, Samsung Display Co., Ltd., 181 Samsung-ro, Tangjeong-myeon, Asan-si, Chungcheongnam-do, 31454 Republic of Korea
| | - Kicheol Song
- Analytical Engineering Team, Samsung Display Co., Ltd., 181 Samsung-ro, Tangjeong-myeon, Asan-si, Chungcheongnam-do, 31454 Republic of Korea
| | - Nari Ahn
- Analytical Engineering Team, Samsung Display Co., Ltd., 181 Samsung-ro, Tangjeong-myeon, Asan-si, Chungcheongnam-do, 31454 Republic of Korea
| | - Jinsoo Park
- Department of Mechanical Engineering, Chonnam National University, 77 Yongbong-ro Buk-gu, Gwangju, 61186 Republic of Korea
| |
Collapse
|
22
|
Xu Z, Chen Z, Yang S, Chen S, Guo T, Chen H. Passive Focusing of Single Cells Using Microwell Arrays for High-Accuracy Image-Activated Sorting. Anal Chem 2024; 96:347-354. [PMID: 38153415 DOI: 10.1021/acs.analchem.3c04195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2023]
Abstract
Sorting single cells from a population was of critical importance in areas such as cell line development and cell therapy. Image-based sorting is becoming a promising technique for the nonlabeling isolation of cells due to the capability of providing the details of cell morphology. This study reported the focusing of cells using microwell arrays and the following automatic size sorting based on the real-time recognition of cells. The simulation first demonstrated the converged streamlines to the symmetrical plane contributed to the focusing effect. Then, the influence of connecting microchannel, flowing length, particle size, and the sample flow rate on the focusing effect was experimentally analyzed. Both microspheres and cells could be aligned in a straight line at the Reynolds number (Re) of 0.027-0.187 and 0.027-0.08, respectively. The connecting channel was proved to drastically improve the focusing performance. Afterward, a tapered microwell array was utilized to focus sphere/cell spreading in a wide channel to a straight line. Finally, a custom algorithm was employed to identify and sort the size of microspheres/K562 cells with a throughput of 1 event/s and an accuracy of 97.8/97.1%. The proposed technique aligned cells to a straight line at low Reynolds numbers and greatly facilitated the image-activated sorting without the need for a high-speed camera or flow control components with high frequency. Therefore, it is of enormous application potential in the field of nonlabeled separation of single cells.
Collapse
Affiliation(s)
- Zheng Xu
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China
| | - Zhenlin Chen
- Department of Biomedical Engineering, College of Engineering, Kowloon, City University of Hong Kong, Hong Kong SAR, China
| | - Shiming Yang
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China
| | - Siyuan Chen
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China
| | - Tianruo Guo
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Huaying Chen
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China
| |
Collapse
|
23
|
Peng T, Qiang J, Yuan S. Sheathless inertial particle focusing methods within microfluidic devices: a review. Front Bioeng Biotechnol 2024; 11:1331968. [PMID: 38260735 PMCID: PMC10801244 DOI: 10.3389/fbioe.2023.1331968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Accepted: 12/18/2023] [Indexed: 01/24/2024] Open
Abstract
The ability to manipulate and focus particles within microscale fluidic environments is crucial to advancing biological, chemical, and medical research. Precise and high-throughput particle focusing is an essential prerequisite for various applications, including cell counting, biomolecular detection, sample sorting, and enhancement of biosensor functionalities. Active and sheath-assisted focusing techniques offer accuracy but necessitate the introduction of external energy fields or additional sheath flows. In contrast, passive focusing methods exploit the inherent fluid dynamics in achieving high-throughput focusing without external actuation. This review analyzes the latest developments in strategies of sheathless inertial focusing, emphasizing inertial and elasto-inertial microfluidic focusing techniques from the channel structure classifications. These methodologies will serve as pivotal benchmarks for the broader application of microfluidic focusing technologies in biological sample manipulation. Then, prospects for future development are also predicted. This paper will assist in the understanding of the design of microfluidic particle focusing devices.
Collapse
Affiliation(s)
- Tao Peng
- Zhuhai UM Science & Technology Research Institute, Zhuhai, China
| | - Jun Qiang
- The School of Mechanical Engineering, Ningxia University, Yinchuan, Ningxia, China
| | - Shuai Yuan
- State Key Laboratory of High Performance Complex Manufacturing, College of Mechanical and Electrical Engineering, Central South University, Changsha, Hunan, China
| |
Collapse
|
24
|
Shen S, Zhang Y, Yang K, Chan H, Li W, Li X, Tian C, Niu Y. Flow-Rate-Insensitive Plasma Extraction by the Stabilization and Acceleration of Secondary Flow in the Ultralow Aspect Ratio Spiral Channel. Anal Chem 2023; 95:18278-18286. [PMID: 38016025 DOI: 10.1021/acs.analchem.3c04179] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2023]
Abstract
Although microfluidic devices have made remarkable strides in blood cell separation, there is still a need for further development and improvement in this area. Herein, we present a novel ultralow aspect ratio (H/W = 1:36) spiral channel microfluidic device with ordered micro-obstacles for sheathless and flow-rate-insensitive blood cell separation. By introducing ordered micro-obstacles into the spiral microchannels, reduced magnitude fluctuations in secondary flow across different loops can be obtained through geometric confinement. As a result, the unique Dean-like secondary flow can effectively enhance the separation efficiency of particles in different sizes ranging from 3 to 15 μm. Compared to most existing microfluidic devices, our system offers several advantages of easy manufacturing, convenient operation, long-term stability, highly efficient performance (up to 99.70% rejection efficiency, including platelets), and most importantly, insensitivity to cell sizes as well as flow rates (allowing for efficient separation of different-sized blood cells in a wide flow rate from 1.00 to 2.50 mL/min). The unique characteristics, such as ultralow aspect ratio, sequential micro-obstacles, and controlled secondary flow, make our device a promising solution for practical plasma extraction in biomedical research and clinical applications.
Collapse
Affiliation(s)
- Shaofei Shen
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taiyuan 030000, Shanxi, P. R. China
| | - Yali Zhang
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taiyuan 030000, Shanxi, P. R. China
| | - Kai Yang
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taiyuan 030000, Shanxi, P. R. China
| | - Henryk Chan
- Department of Automatic Control and Systems Engineering, The University of Sheffield, Sheffield S10 2TN, U.K
| | - Weiwen Li
- Department of Breast, Jiangmen Central Hospital, Jiangmen 529000, Guangdong, P. R. China
| | - Xiaoping Li
- Department of Breast, Jiangmen Central Hospital, Jiangmen 529000, Guangdong, P. R. China
| | - Chang Tian
- School of Medicine, Anhui University of Science and Technology, Huainan 232001, Anhui, P. R. China
| | - Yanbing Niu
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taiyuan 030000, Shanxi, P. R. China
| |
Collapse
|
25
|
Saffar Y, Kashanj S, Nobes DS, Sabbagh R. The Physics and Manipulation of Dean Vortices in Single- and Two-Phase Flow in Curved Microchannels: A Review. MICROMACHINES 2023; 14:2202. [PMID: 38138371 PMCID: PMC10745399 DOI: 10.3390/mi14122202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Revised: 11/28/2023] [Accepted: 11/30/2023] [Indexed: 12/24/2023]
Abstract
Microchannels with curved geometries have been employed for many applications in microfluidic devices in the past decades. The Dean vortices generated in such geometries have been manipulated using different methods to enhance the performance of devices in applications such as mixing, droplet sorting, and particle/cell separation. Understanding the effect of the manipulation method on the Dean vortices in different geometries can provide crucial information to be employed in designing high-efficiency microfluidic devices. In this review, the physics of Dean vortices and the affecting parameters are summarized. Various Dean number calculation methods are collected and represented to minimize the misinterpretation of published information due to the lack of a unified defining formula for the Dean dimensionless number. Consequently, all Dean number values reported in the references are recalculated to the most common method to facilitate comprehension of the phenomena. Based on the converted information gathered from previous numerical and experimental studies, it is concluded that the length of the channel and the channel pathline, e.g., spiral, serpentine, or helix, also affect the flow state. This review also provides a detailed summery on the effect of other geometric parameters, such as cross-section shape, aspect ratio, and radius of curvature, on the Dean vortices' number and arrangement. Finally, considering the importance of droplet microfluidics, the effect of curved geometry on the shape, trajectory, and internal flow organization of the droplets passing through a curved channel has been reviewed.
Collapse
Affiliation(s)
| | | | | | - Reza Sabbagh
- Mechanical Engineering Department, University of Alberta, Edmonton, AB T6G 2R3, Canada; (Y.S.); (S.K.); (D.S.N.)
| |
Collapse
|
26
|
Cao X, Li Q, Li X, Liu Q, Liu K, Deng T, Weng X, Yu Q, Deng W, Yu J, Wang Q, Xiao G, Xu X. Enhancing Anticancer Efficacy of Formononetin Microspheres via Microfluidic Fabrication. AAPS PharmSciTech 2023; 24:241. [PMID: 38017231 DOI: 10.1208/s12249-023-02691-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Accepted: 10/30/2023] [Indexed: 11/30/2023] Open
Abstract
Formononetin is a flavonoid compound with anti-tumor and anti-inflammatory properties. However, its low solubility limits its clinical use. We employed microfluidic technology to prepare formononetin-loaded PLGA-PEGDA microspheres (Degradable polymer PLGA, Crosslinking agent PEGDA), which can encapsulate and release drugs in a controlled manner. We optimized and characterized the microspheres, and evaluated their antitumor effects. The microspheres had uniform size, high drug loading efficiency, high encapsulation efficiency, and stable release for 35 days. They also inhibited the proliferation, migration, and apoptosis. The antitumor mechanism involved the induction of reactive oxygen species and modulation of Bcl-2 family proteins. These findings suggested that formononetin-loaded PLGA-PEGDA microspheres, created using microfluidic technology, could be a novel drug delivery system that can overcome the limitations of formononetin and enhance its antitumor activity.
Collapse
Affiliation(s)
- Xia Cao
- Department of Pharmaceutics, School of Pharmacy, Centre for Nano Drug/Gene Delivery and Tissue Engineering, Jiangsu University, Zhenjiang, People's Republic of China
- Medicinal function development of new food resources, Jiangsu Provincial Research Center, Jiangsu, People's Republic of China
| | - Qingwen Li
- Department of Pharmaceutics, School of Pharmacy, Centre for Nano Drug/Gene Delivery and Tissue Engineering, Jiangsu University, Zhenjiang, People's Republic of China
- Medicinal function development of new food resources, Jiangsu Provincial Research Center, Jiangsu, People's Republic of China
| | - Xiaoli Li
- Department of Pharmaceutics, School of Pharmacy, Centre for Nano Drug/Gene Delivery and Tissue Engineering, Jiangsu University, Zhenjiang, People's Republic of China
- Medicinal function development of new food resources, Jiangsu Provincial Research Center, Jiangsu, People's Republic of China
| | - Qi Liu
- Department of Pharmaceutics, School of Pharmacy, Centre for Nano Drug/Gene Delivery and Tissue Engineering, Jiangsu University, Zhenjiang, People's Republic of China
- Medicinal function development of new food resources, Jiangsu Provincial Research Center, Jiangsu, People's Republic of China
| | - Kai Liu
- Department of Pharmaceutics, School of Pharmacy, Centre for Nano Drug/Gene Delivery and Tissue Engineering, Jiangsu University, Zhenjiang, People's Republic of China
- Medicinal function development of new food resources, Jiangsu Provincial Research Center, Jiangsu, People's Republic of China
| | - Tianwen Deng
- Department of Pharmaceutics, School of Pharmacy, Centre for Nano Drug/Gene Delivery and Tissue Engineering, Jiangsu University, Zhenjiang, People's Republic of China
- Medicinal function development of new food resources, Jiangsu Provincial Research Center, Jiangsu, People's Republic of China
| | - Xuedi Weng
- Department of Pharmaceutics, School of Pharmacy, Centre for Nano Drug/Gene Delivery and Tissue Engineering, Jiangsu University, Zhenjiang, People's Republic of China
| | - Qintong Yu
- Department of Pharmaceutics, School of Pharmacy, Centre for Nano Drug/Gene Delivery and Tissue Engineering, Jiangsu University, Zhenjiang, People's Republic of China
- Medicinal function development of new food resources, Jiangsu Provincial Research Center, Jiangsu, People's Republic of China
| | - Wenwen Deng
- Department of Pharmaceutics, School of Pharmacy, Centre for Nano Drug/Gene Delivery and Tissue Engineering, Jiangsu University, Zhenjiang, People's Republic of China
- Medicinal function development of new food resources, Jiangsu Provincial Research Center, Jiangsu, People's Republic of China
| | - Jiangnan Yu
- Department of Pharmaceutics, School of Pharmacy, Centre for Nano Drug/Gene Delivery and Tissue Engineering, Jiangsu University, Zhenjiang, People's Republic of China
- Medicinal function development of new food resources, Jiangsu Provincial Research Center, Jiangsu, People's Republic of China
| | - Qilong Wang
- Department of Pharmaceutics, School of Pharmacy, Centre for Nano Drug/Gene Delivery and Tissue Engineering, Jiangsu University, Zhenjiang, People's Republic of China.
- Medicinal function development of new food resources, Jiangsu Provincial Research Center, Jiangsu, People's Republic of China.
| | - Gao Xiao
- College of Environment and Safety Engineering, Fuzhou University, Fuzhou, 350108, Fujian, People's Republic of China.
| | - Ximing Xu
- Department of Pharmaceutics, School of Pharmacy, Centre for Nano Drug/Gene Delivery and Tissue Engineering, Jiangsu University, Zhenjiang, People's Republic of China.
- Medicinal function development of new food resources, Jiangsu Provincial Research Center, Jiangsu, People's Republic of China.
| |
Collapse
|
27
|
Borenstein JT, Cummins G, Dutta A, Hamad E, Hughes MP, Jiang X, Lee HH, Lei KF, Tang XS, Zheng Y, Chen J. Bionanotechnology and bioMEMS (BNM): state-of-the-art applications, opportunities, and challenges. LAB ON A CHIP 2023; 23:4928-4949. [PMID: 37916434 DOI: 10.1039/d3lc00296a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/03/2023]
Abstract
The development of micro- and nanotechnology for biomedical applications has defined the cutting edge of medical technology for over three decades, as advancements in fabrication technology developed originally in the semiconductor industry have been applied to solving ever-more complex problems in medicine and biology. These technologies are ideally suited to interfacing with life sciences, since they are on the scale lengths as cells (microns) and biomacromolecules (nanometers). In this paper, we review the state of the art in bionanotechnology and bioMEMS (collectively BNM), including developments and challenges in the areas of BNM, such as microfluidic organ-on-chip devices, oral drug delivery, emerging technologies for managing infectious diseases, 3D printed microfluidic devices, AC electrokinetics, flexible MEMS devices, implantable microdevices, paper-based microfluidic platforms for cellular analysis, and wearable sensors for point-of-care testing.
Collapse
Affiliation(s)
| | - Gerard Cummins
- School of Engineering, University of Birmingham, Edgbaston, B15 2TT, UK.
| | - Abhishek Dutta
- Department of Electrical & Computer Engineering, University of Connecticut, USA.
| | - Eyad Hamad
- Biomedical Engineering Department, School of Applied Medical Sciences, German Jordanian University, Amman, Jordan.
| | - Michael Pycraft Hughes
- Department of Biomedical Engineering, Khalifa University, Abu Dhabi, United Arab Emirates.
| | - Xingyu Jiang
- Department of Biomedical Engineering, Southern University of Science and Technology, China.
| | - Hyowon Hugh Lee
- Weldon School of Biomedical Engineering, Center for Implantable Devices, Purdue University, West Lafayette, IN, USA.
| | | | | | | | - Jie Chen
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 2R3, Canada.
| |
Collapse
|
28
|
Huang Y, Liu C, Feng Q, Sun J. Microfluidic synthesis of nanomaterials for biomedical applications. NANOSCALE HORIZONS 2023; 8:1610-1627. [PMID: 37723984 DOI: 10.1039/d3nh00217a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/20/2023]
Abstract
The field of nanomaterials has progressed dramatically over the past decades with important contributions to the biomedical area. The physicochemical properties of nanomaterials, such as the size and structure, can be controlled through manipulation of mass and heat transfer conditions during synthesis. In particular, microfluidic systems with rapid mixing and precise fluid control are ideal platforms for creating appropriate synthesis conditions. One notable example of microfluidics-based synthesis is the development of lipid nanoparticle (LNP)-based mRNA vaccines with accelerated clinical translation and robust efficacy during the COVID-19 pandemic. In addition to LNPs, microfluidic systems have been adopted for the controlled synthesis of a broad range of nanomaterials. In this review, we introduce the fundamental principles of microfluidic technologies including flow field- and multiple field-based methods for fabricating nanoparticles, and discuss their applications in the biomedical field. We conclude this review by outlining several major challenges and future directions in the implementation of microfluidic synthesis of nanomaterials.
Collapse
Affiliation(s)
- Yanjuan Huang
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Laboratory of Standardization and Measurement for Nanotechnology, National Center for Nanoscience and Technology, Beijing 100190, China.
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Chao Liu
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Laboratory of Standardization and Measurement for Nanotechnology, National Center for Nanoscience and Technology, Beijing 100190, China.
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Qiang Feng
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Laboratory of Standardization and Measurement for Nanotechnology, National Center for Nanoscience and Technology, Beijing 100190, China.
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jiashu Sun
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Laboratory of Standardization and Measurement for Nanotechnology, National Center for Nanoscience and Technology, Beijing 100190, China.
- University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
29
|
Torres-Castro K, Acuña-Umaña K, Lesser-Rojas L, Reyes DR. Microfluidic Blood Separation: Key Technologies and Critical Figures of Merit. MICROMACHINES 2023; 14:2117. [PMID: 38004974 PMCID: PMC10672873 DOI: 10.3390/mi14112117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 11/01/2023] [Accepted: 11/10/2023] [Indexed: 11/26/2023]
Abstract
Blood is a complex sample comprised mostly of plasma, red blood cells (RBCs), and other cells whose concentrations correlate to physiological or pathological health conditions. There are also many blood-circulating biomarkers, such as circulating tumor cells (CTCs) and various pathogens, that can be used as measurands to diagnose certain diseases. Microfluidic devices are attractive analytical tools for separating blood components in point-of-care (POC) applications. These platforms have the potential advantage of, among other features, being compact and portable. These features can eventually be exploited in clinics and rapid tests performed in households and low-income scenarios. Microfluidic systems have the added benefit of only needing small volumes of blood drawn from patients (from nanoliters to milliliters) while integrating (within the devices) the steps required before detecting analytes. Hence, these systems will reduce the associated costs of purifying blood components of interest (e.g., specific groups of cells or blood biomarkers) for studying and quantifying collected blood fractions. The microfluidic blood separation field has grown since the 2000s, and important advances have been reported in the last few years. Nonetheless, real POC microfluidic blood separation platforms are still elusive. A widespread consensus on what key figures of merit should be reported to assess the quality and yield of these platforms has not been achieved. Knowing what parameters should be reported for microfluidic blood separations will help achieve that consensus and establish a clear road map to promote further commercialization of these devices and attain real POC applications. This review provides an overview of the separation techniques currently used to separate blood components for higher throughput separations (number of cells or particles per minute). We present a summary of the critical parameters that should be considered when designing such devices and the figures of merit that should be explicitly reported when presenting a device's separation capabilities. Ultimately, reporting the relevant figures of merit will benefit this growing community and help pave the road toward commercialization of these microfluidic systems.
Collapse
Affiliation(s)
- Karina Torres-Castro
- Biophysical and Biomedical Measurements Group, National Institute of Standards and Technology (NIST), 100 Bureau Drive, Gaithersburg, MD 20899, USA;
- Theiss Research, La Jolla, CA 92037, USA
| | - Katherine Acuña-Umaña
- Medical Devices Master’s Program, Instituto Tecnológico de Costa Rica (ITCR), Cartago 30101, Costa Rica
| | - Leonardo Lesser-Rojas
- Research Center in Atomic, Nuclear and Molecular Sciences (CICANUM), San José 11501, Costa Rica;
- School of Physics, Universidad de Costa Rica (UCR), San José 11501, Costa Rica
| | - Darwin R. Reyes
- Biophysical and Biomedical Measurements Group, National Institute of Standards and Technology (NIST), 100 Bureau Drive, Gaithersburg, MD 20899, USA;
| |
Collapse
|
30
|
Wang W, Wang Y, Zhang D, Guo G, Wang L, Wang X. Kinetically Controlled Nucleation Enabled by Tunable Microfluidic Mixing for the Synthesis of Dendritic Au@Pt Core/Shell Nanomaterials. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023:e2302589. [PMID: 37967327 DOI: 10.1002/smll.202302589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 10/05/2023] [Indexed: 11/17/2023]
Abstract
The nucleation stage plays a decisive role in determining nanocrystal morphology and properties; hence, the ability to regulate nucleation is critical for achieving high-level control. Herein, glass microfluidic chips with S-shaped mixing units are designed for the synthesis of Au@Pt core/shell materials. The use of hydrodynamics to tune the nucleation kinetics is explored by varying the number of mixing units. Dendritic Au@Pt core/shell nanomaterials are controllably synthesized and a formation mechanism is proposed. As-synthesized Au@Pt exhibited excellent ethanol oxidation activity under alkaline conditions (8.4 times that of commercial Pt/C). This approach is also successfully applied to the synthesize of Au@Pd core/shell nanomaterials, thus demonstrating its generality.
Collapse
Affiliation(s)
- Wubin Wang
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry, Beijing University of Technology, Beijing, 100124, China
| | - Yacheng Wang
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry, Beijing University of Technology, Beijing, 100124, China
| | - Dongtang Zhang
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry, Beijing University of Technology, Beijing, 100124, China
| | - Guangsheng Guo
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry, Beijing University of Technology, Beijing, 100124, China
- Minzu University of China, Beijing, 100081, China
| | - Leyu Wang
- State Key Laboratory of Chemical Resource Engineering, Beijing Advanced Innovation Center for Soft Matter Science and Engineering, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Xiayan Wang
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry, Beijing University of Technology, Beijing, 100124, China
| |
Collapse
|
31
|
Shen S, Bai H, Wang X, Chan H, Niu Y, Li W, Tian C, Li X. High-Throughput Blood Plasma Extraction in a Dimension-Confined Double-Spiral Channel. Anal Chem 2023; 95:16649-16658. [PMID: 37917001 DOI: 10.1021/acs.analchem.3c03002] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2023]
Abstract
Microfluidic technologies enabling the control of secondary flow are essential for the successful separation of blood cells, a process that is beneficial for a wide range of medical research and clinical diagnostics. Herein, we introduce a dimension-confined microfluidic device featuring a double-spiral channel designed to regulate secondary flows, thereby enabling high-throughput isolation of blood for plasma extraction. By integrating a sequence of micro-obstacles within the double-spiral microchannels, the stable and enhanced Dean-like secondary flow across each loop can be generated. This setup consequently prompts particles of varying diameters (3, 7, 10, and 15 μm) to form different focusing states. Crucially, this system is capable of effectively separating blood cells of different sizes with a cell throughput of (2.63-3.36) × 108 cells/min. The concentration of blood cells in outlet 2 increased 3-fold, from 1.46 × 108 to 4.37 × 108, while the number of cells, including platelets, exported from outlets 1 and 3 decreased by a factor of 608. The engineering approach manipulating secondary flow for plasma extraction points to simplicity in fabrication, ease of operation, insensitivity to cell size, high throughput, and separation efficiency, which has potential utility in propelling the development of miniaturized diagnostic devices in the field of biomedical science.
Collapse
Affiliation(s)
- Shaofei Shen
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taiyuan 030000, Shanxi, P. R. China
| | - Hanjie Bai
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taiyuan 030000, Shanxi, P. R. China
| | - Xin Wang
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taiyuan 030000, Shanxi, P. R. China
| | - Henryk Chan
- Department of Automatic Control and Systems Engineering, The University of Sheffield, Sheffield S10 2TN, U.K
| | - Yanbing Niu
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taiyuan 030000, Shanxi, P. R. China
| | - Weiwen Li
- Department of Breast, Jiangmen Central Hospital, Jiangmen 529000, Guangdong, P. R. China
| | - Chang Tian
- School of Medicine, Anhui University of Science and Technology, Huainan 232001, Anhui, P. R. China
| | - Xiaoping Li
- Department of Breast, Jiangmen Central Hospital, Jiangmen 529000, Guangdong, P. R. China
| |
Collapse
|
32
|
Suzuki T, Kalyan S, Berlinicke C, Yoseph S, Zack DJ, Hur SC. Deciphering viscoelastic cell manipulation in rectangular microchannels. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2023; 35:103117. [PMID: 37849975 PMCID: PMC10577600 DOI: 10.1063/5.0167285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Accepted: 09/25/2023] [Indexed: 10/19/2023]
Abstract
Viscoelastic focusing has emerged as a promising method for label-free and passive manipulation of micro and nanoscale bioparticles. However, the design of microfluidic devices for viscoelastic particle focusing requires a thorough comprehensive understanding of the flow condition and operational parameters that lead to the desired behavior of microparticles. While recent advancements have been made, viscoelastic focusing is not fully understood, particularly in straight microchannels with rectangular cross sections. In this work, we delve into inertial, elastic, and viscoelastic focusing of biological cells in rectangular cross-section microchannels. By systematically varying degrees of fluid elasticity and inertia, we investigate the underlying mechanisms behind cell focusing. Our approach involves injecting cells into devices with a fixed, non-unity aspect ratio and capturing their images from two orientations, enabling the extrapolation of cross-sectional equilibrium positions from two dimensional (2D) projections. We characterized the changes in hydrodynamic focusing behaviors of cells based on factors, such as cell size, flow rate, and fluid characteristics. These findings provide insights into the flow characteristics driving changes in equilibrium positions. Furthermore, they indicate that viscoelastic focusing can enhance the detection accuracy in flow cytometry and the sorting resolution for size-based particle sorting applications. By contributing to the advancement of understanding viscoelastic focusing in rectangular microchannels, this work provides valuable insight and design guidelines for the development of devices that harness viscoelastic focusing. The knowledge gained from this study can aid in the advancement of viscoelastic particle manipulation technique and their application in various fields.
Collapse
Affiliation(s)
- Takayuki Suzuki
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, Maryland 21218, USA
| | - Srivathsan Kalyan
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, Maryland 21218, USA
| | - Cynthia Berlinicke
- Department of Ophthalmology, Wilmer Institute, Johns Hopkins University School of Medicine, Baltimore, Maryland 21287, USA
| | - Samantha Yoseph
- Department of Architecture, University of Maryland, College Park, Maryland 20742, USA
| | | | | |
Collapse
|
33
|
Wang S, Xu Q, Zhang Z, Chen S, Jiang Y, Feng Z, Wang D, Jiang X. Reverse flow enhanced inertia pinched flow fractionation. LAB ON A CHIP 2023; 23:4324-4333. [PMID: 37702391 DOI: 10.1039/d3lc00473b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/14/2023]
Abstract
Particle separation plays a critical role in many biochemical analyses. In this article, we report a method of reverse flow enhanced inertia pinched flow fractionation (RF-iPFF) for particle separation. RF-iPFF separates particles by size based on the flow-induced inertial lift, and in the abruptly broadened segment, reverse flow is utilized to further enhance the separation distance between particles of different sizes. The separation performance can be significantly improved by reverse flow. Generally, compared with the case without reverse flow, this RF-iPFF technique can increase the particle throughput by about 10 times. To demonstrate the advantages of RF-iPFF, RF-iPFF was compared with traditional iPFF through a control experiment. RF-iPFF consistently outperformed iPFF across various conditions we studied. In addition, we use tumor cells spiked into the human whole blood to evaluate the separation performance of RF-iPFF.
Collapse
Affiliation(s)
- Saijie Wang
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China.
| | - Quanchen Xu
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China.
| | - Zhihan Zhang
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China.
| | - Shengbo Chen
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China.
| | - Yizhou Jiang
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China.
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Zhuowei Feng
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China.
| | - Dou Wang
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China.
| | - Xingyu Jiang
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China.
| |
Collapse
|
34
|
Akbari Z, Raoufi MA, Mirjalali S, Aghajanloo B. A review on inertial microfluidic fabrication methods. BIOMICROFLUIDICS 2023; 17:051504. [PMID: 37869745 PMCID: PMC10589053 DOI: 10.1063/5.0163970] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Accepted: 10/02/2023] [Indexed: 10/24/2023]
Abstract
In recent decades, there has been significant interest in inertial microfluidics due to its high throughput, ease of fabrication, and no need for external forces. The focusing efficiency of inertial microfluidic systems relies entirely on the geometrical features of microchannels because hydrodynamic forces (inertial lift forces and Dean drag forces) are the main driving forces in inertial microfluidic devices. In the past few years, novel microchannel structures have been propounded to improve particle manipulation efficiency. However, the fabrication of these unconventional structures has remained a serious challenge. Although researchers have pushed forward the frontiers of microfabrication technologies, the fabrication techniques employed for inertial microfluidics have not been discussed comprehensively. This review introduces the microfabrication approaches used for creating inertial microchannels, including photolithography, xurography, laser cutting, micromachining, microwire technique, etching, hot embossing, 3D printing, and injection molding. The advantages and disadvantages of these methods have also been discussed. Then, the techniques are reviewed regarding resolution, structures, cost, and materials. This review provides a thorough insight into the manufacturing methods of inertial microchannels, which could be helpful for future studies to improve the harvesting yield and resolution by choosing a proper fabrication technique.
Collapse
Affiliation(s)
- Zohreh Akbari
- Department of Mechanical Engineering, Ferdowsi University of Mashhad, Mashhad, Iran
| | | | - Sheyda Mirjalali
- School of Engineering, Macquarie University, Sydney, New South Wales, Australia
| | - Behrouz Aghajanloo
- School of Engineering, Macquarie University, Sydney, New South Wales, Australia
| |
Collapse
|
35
|
Rashidi Y, Aouane O, Darras A, John T, Harting J, Wagner C, Recktenwald SM. Cell-free layer development and spatial organization of healthy and rigid red blood cells in a microfluidic bifurcation. SOFT MATTER 2023; 19:6255-6266. [PMID: 37522517 DOI: 10.1039/d3sm00517h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/01/2023]
Abstract
Bifurcations and branches in the microcirculation dramatically affect blood flow as they determine the spatiotemporal organization of red blood cells (RBCs). Such changes in vessel geometries can further influence the formation of a cell-free layer (CFL) close to the vessel walls. Biophysical cell properties, such as their deformability, which is impaired in various diseases, are often thought to impact blood flow and affect the distribution of flowing RBCs. This study investigates the flow behavior of healthy and artificially hardened RBCs in a bifurcating microfluidic T-junction. We determine the RBC distribution across the channel width at multiple positions before and after the bifurcation. Thus, we reveal distinct focusing profiles in the feeding mother channel for rigid and healthy RBCs that dramatically impact the cell organization in the successive daughter channels. Moreover, we experimentally show how the characteristic asymmetric CFLs in the daughter vessels develop along their flow direction. Complimentary numerical simulations indicate that the buildup of the CFL is faster for healthy than for rigid RBCs. Our results provide fundamental knowledge to understand the partitioning of rigid RBC as a model of cells with pathologically impaired deformability in complex in vitro networks.
Collapse
Affiliation(s)
- Yazdan Rashidi
- Dynamics of Fluids, Department of Experimental Physics, Saarland University, 66123 Saarbrücken, Germany.
| | - Othmane Aouane
- Helmholtz Institute Erlangen-Nürnberg for Renewable Energy, Forschungszentrum Jülich, 91058 Erlangen, Germany
| | - Alexis Darras
- Dynamics of Fluids, Department of Experimental Physics, Saarland University, 66123 Saarbrücken, Germany.
| | - Thomas John
- Dynamics of Fluids, Department of Experimental Physics, Saarland University, 66123 Saarbrücken, Germany.
| | - Jens Harting
- Helmholtz Institute Erlangen-Nürnberg for Renewable Energy, Forschungszentrum Jülich, 91058 Erlangen, Germany
- Department of Chemical and Biological Engineering and Department of Physics, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058 Erlangen, Germany
| | - Christian Wagner
- Dynamics of Fluids, Department of Experimental Physics, Saarland University, 66123 Saarbrücken, Germany.
- Department of Physics and Materials Science, University of Luxembourg, 1511 Luxembourg City, Luxembourg
| | - Steffen M Recktenwald
- Dynamics of Fluids, Department of Experimental Physics, Saarland University, 66123 Saarbrücken, Germany.
| |
Collapse
|
36
|
Liu X, Zhou J, Yan R, Tang T, Wei S, Li R, Hou D, Weng Y, Wang D, Shen H, Zhou F, Tanaka Y, Li M, Hosokawa Y, Yalikun Y, Lei C. An optimized PDMS microfluidic device for ultra-fast and high-throughput imaging flow cytometry. LAB ON A CHIP 2023; 23:3571-3580. [PMID: 37401791 DOI: 10.1039/d3lc00237c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/05/2023]
Abstract
Imaging flow cytometry (IFC) is a powerful tool for cell detection and analysis due to its high throughput and compatibility in image acquisition. Optical time-stretch (OTS) imaging is considered as one of the most promising imaging techniques for IFC because it can realize cell imaging at a flow speed of around 60 m s-1. However, existing PDMS-based microchannels cannot function at flow velocities higher than 10 m s-1; thus the capability of OTS-based IFC is significantly limited. To overcome the velocity barrier for PDMS-based microchannels, we proposed an optimized design of PDMS-based microchannels with reduced hydraulic resistance and 3D hydrodynamic focusing capability, which can drive fluids at an ultra-high flow velocity (of up to 40 m s-1) by using common syringe pumps. To verify the feasibility of our design, we fabricated and installed the microchannel in an OTS IFC system. The experimental results first proved that the proposed microchannel can support a stable flow velocity of up to 40 m s-1 without any leakage or damage. Then, we demonstrated that the OTS IFC is capable of imaging cells at a velocity of up to 40 m s-1 with good quality. To the best of our knowledge, it is the first time that IFC has achieved such a high flow velocity just by using a PDMS-glass chip. Moreover, high velocity can enhance the focusing of cells on the optical focal plane, increasing the number of detected cells and the throughput. This work provides a promising solution for IFC to fully release its capability of advanced imaging techniques by operating at an extremely high screening throughput.
Collapse
Affiliation(s)
- Xun Liu
- The Institute of Technological Sciences, Wuhan University, Wuhan, 430072, China.
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayama-cho, Ikoma, Nara 630-0192, Japan.
| | - Jiehua Zhou
- The Institute of Technological Sciences, Wuhan University, Wuhan, 430072, China.
| | - Ruopeng Yan
- The Institute of Technological Sciences, Wuhan University, Wuhan, 430072, China.
| | - Tao Tang
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayama-cho, Ikoma, Nara 630-0192, Japan.
| | - Shubin Wei
- The Institute of Technological Sciences, Wuhan University, Wuhan, 430072, China.
| | - Rubing Li
- The Institute of Technological Sciences, Wuhan University, Wuhan, 430072, China.
| | - Dan Hou
- The Institute of Technological Sciences, Wuhan University, Wuhan, 430072, China.
| | - Yueyun Weng
- The Institute of Technological Sciences, Wuhan University, Wuhan, 430072, China.
| | - Du Wang
- The Institute of Technological Sciences, Wuhan University, Wuhan, 430072, China.
| | - Hui Shen
- Department of Hematology, Renmin Hospital of Wuhan University, Wuhan, 430072, China
| | - Fuling Zhou
- Department of Hematology, Renmin Hospital of Wuhan University, Wuhan, 430072, China
| | - Yo Tanaka
- Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka Suita, Osaka, 565-0871, Japan
| | - Ming Li
- School of Engineering, Macquarie University, Sydney, 2109, Australia
| | - Yoichiroh Hosokawa
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayama-cho, Ikoma, Nara 630-0192, Japan.
| | - Yaxiaer Yalikun
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayama-cho, Ikoma, Nara 630-0192, Japan.
| | - Cheng Lei
- The Institute of Technological Sciences, Wuhan University, Wuhan, 430072, China.
| |
Collapse
|
37
|
Kechagidis K, Owen B, Guillou L, Tse H, Di Carlo D, Krüger T. Numerical investigation of the dynamics of a rigid spherical particle in a vortical cross-slot flow at moderate inertia. MICROSYSTEMS & NANOENGINEERING 2023; 9:100. [PMID: 37519826 PMCID: PMC10372015 DOI: 10.1038/s41378-023-00541-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 03/22/2023] [Accepted: 04/25/2023] [Indexed: 08/01/2023]
Abstract
The study of flow and particle dynamics in microfluidic cross-slot channels is of high relevance for lab-on-a-chip applications. In this work, we investigate the dynamics of a rigid spherical particle in a cross-slot junction for a channel height-to-width ratio of 0.6 and at a Reynolds number of 120 for which a steady vortex exists in the junction area. Using an in-house immersed-boundary-lattice-Boltzmann code, we analyse the effect of the entry position of the particle in the junction and the particle size on the dynamics and trajectory shape of the particle. We find that the dynamics of the particle depend strongly on its lateral entry position in the junction and weakly on its vertical entry position; particles that enter close to the centre show trajectory oscillations. Larger particles have longer residence times in the junction and tend to oscillate less due to their confinement. Our work contributes to the understanding of particle dynamics in intersecting flows and enables the design of optimised geometries for cytometry and particle manipulation.
Collapse
Affiliation(s)
- Konstantinos Kechagidis
- School of Engineering, Institute for Multiscale Thermofluids, University of Edinburgh, W Mains Rd, Edinburgh, EH9 3JW Scotland UK
| | - Benjamin Owen
- School of Engineering, Institute for Multiscale Thermofluids, University of Edinburgh, W Mains Rd, Edinburgh, EH9 3JW Scotland UK
| | - Lionel Guillou
- Cytovale, Inc., Executive Park Blvd., San Fransisco, CA 90095 CA USA
| | - Henry Tse
- Cytovale, Inc., Executive Park Blvd., San Fransisco, CA 90095 CA USA
| | - Dino Di Carlo
- Department of Bioengineering, University of California, Westwood Plaza, Los Angeles, 610101 CA USA
| | - Timm Krüger
- School of Engineering, Institute for Multiscale Thermofluids, University of Edinburgh, W Mains Rd, Edinburgh, EH9 3JW Scotland UK
| |
Collapse
|
38
|
Knüppel F, Sun A, Wurm FH, Hussong J, Torner B. Effect of Particle Migration on the Stress Field in Microfluidic Flows of Blood Analog Fluids at High Reynolds Numbers. MICROMACHINES 2023; 14:1494. [PMID: 37630030 PMCID: PMC10456677 DOI: 10.3390/mi14081494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 07/19/2023] [Accepted: 07/21/2023] [Indexed: 08/27/2023]
Abstract
In the present paper, we investigate how the reductions in shear stresses and pressure losses in microfluidic gaps are directly linked to the local characteristics of cell-free layers (CFLs) at channel Reynolds numbers relevant to ventricular assist device (VAD) applications. For this, detailed studies of local particle distributions of a particulate blood analog fluid are combined with wall shear stress and pressure loss measurements in two complementary set-ups with identical flow geometry, bulk Reynolds numbers and particle Reynolds numbers. For all investigated particle volume fractions of up to 5%, reductions in the stress and pressure loss were measured in comparison to a flow of an equivalent homogeneous fluid (without particles). We could explain this due to the formation of a CFL ranging from 10 to 20 μm. Variations in the channel Reynolds number between Re = 50 and 150 did not lead to measurable changes in CFL heights or stress reductions for all investigated particle volume fractions. These measurements were used to describe the complete chain of how CFL formation leads to a stress reduction, which reduces the apparent viscosity of the suspension and results in the Fåhræus-Lindqvist effect. This chain of causes was investigated for the first time for flows with high Reynolds numbers (Re∼100), representing a flow regime which can be found in the narrow gaps of a VAD.
Collapse
Affiliation(s)
- Finn Knüppel
- Institute of Turbomachinery, Faculty for Mechanical Engineering and Ship Design, University of Rostock, 18055 Rostock, Germany; (F.K.); (F.-H.W.)
| | - Ang Sun
- Institute for Fluid Mechanics and Aerodynamics, Technical University of Darmstadt, 64287 Darmstadt, Germany; (A.S.); (J.H.)
| | - Frank-Hendrik Wurm
- Institute of Turbomachinery, Faculty for Mechanical Engineering and Ship Design, University of Rostock, 18055 Rostock, Germany; (F.K.); (F.-H.W.)
| | - Jeanette Hussong
- Institute for Fluid Mechanics and Aerodynamics, Technical University of Darmstadt, 64287 Darmstadt, Germany; (A.S.); (J.H.)
| | - Benjamin Torner
- Institute of Turbomachinery, Faculty for Mechanical Engineering and Ship Design, University of Rostock, 18055 Rostock, Germany; (F.K.); (F.-H.W.)
| |
Collapse
|
39
|
Esan A, Vanholsbeeck F, Swift S, McGoverin CM. Continuous separation of bacterial cells from large debris using a spiral microfluidic device. BIOMICROFLUIDICS 2023; 17:044104. [PMID: 37576440 PMCID: PMC10415021 DOI: 10.1063/5.0159254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Accepted: 07/17/2023] [Indexed: 08/15/2023]
Abstract
With the global increase in food exchange, rapid identification and enumeration of bacteria has become crucial for protecting consumers from bacterial contamination. Efficient analysis requires the separation of target particles (e.g., bacterial cells) from food and/or sampling matrices to prevent matrix interference with the detection and analysis of target cells. However, studies on the separation of bacteria-sized particles and defined particles, such as bacterial cells, from heterogeneous debris, such as meat swab suspensions, are limited. In this study, we explore the use of passive-based inertial microfluidics to separate bacterial cells from debris, such as fascia, muscle tissues, and cotton fibers, extracted from ground meat and meat swabs-a novel approach demonstrated for the first time. Our objective is to evaluate the recovery efficiency of bacterial cells from large debris obtained from ground meat and meat swab suspensions using a spiral microfluidic device. In this study, we establish the optimal flow rates and Dean number for continuous bacterial cell and debris separation and a methodology to determine the percentage of debris removed from the sample suspension. Our findings demonstrate an average recovery efficiency of ∼ 80% for bacterial cells separated from debris in meat swab suspensions, while the average recovery efficiency from ground beef suspensions was ∼ 70%. Furthermore, approximately 50% of the debris in the ground meat suspension were separated from bacterial cells.
Collapse
Affiliation(s)
| | | | - Simon Swift
- Department of Molecular Medicine and Pathology, University of Auckland, Auckland, New Zealand
| | | |
Collapse
|
40
|
Gao H, Zhou J, Naderi MM, Peng Z, Papautsky I. Evolution of focused streams for viscoelastic flow in spiral microchannels. MICROSYSTEMS & NANOENGINEERING 2023; 9:73. [PMID: 37288322 PMCID: PMC10241945 DOI: 10.1038/s41378-023-00520-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 03/05/2023] [Accepted: 03/13/2023] [Indexed: 06/09/2023]
Abstract
Particle migration dynamics in viscoelastic fluids in spiral channels have attracted interest in recent years due to potential applications in the 3D focusing and label-free sorting of particles and cells. Despite a number of recent studies, the underlying mechanism of Dean-coupled elasto-inertial migration in spiral microchannels is not fully understood. In this work, for the first time, we experimentally demonstrate the evolution of particle focusing behavior along a channel downstream length at a high blockage ratio. We found that flow rate, device curvature, and medium viscosity play important roles in particle lateral migration. Our results illustrate the full focusing pattern along the downstream channel length, with side-view imaging yielding observations on the vertical migration of focused streams. Ultimately, we anticipate that these results will offer a useful guide for elasto-inertial microfluidics device design to improve the efficiency of 3D focusing in cell sorting and cytometry applications.
Collapse
Affiliation(s)
- Hua Gao
- Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL 60607 USA
| | - Jian Zhou
- Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL 60607 USA
| | - Mohammad Moein Naderi
- Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL 60607 USA
| | - Zhangli Peng
- Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL 60607 USA
| | - Ian Papautsky
- Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL 60607 USA
| |
Collapse
|
41
|
Farahinia A, Zhang W, Badea I. Recent Developments in Inertial and Centrifugal Microfluidic Systems along with the Involved Forces for Cancer Cell Separation: A Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23115300. [PMID: 37300027 DOI: 10.3390/s23115300] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 04/23/2023] [Accepted: 05/17/2023] [Indexed: 06/12/2023]
Abstract
The treatment of cancers is a significant challenge in the healthcare context today. Spreading circulating tumor cells (CTCs) throughout the body will eventually lead to cancer metastasis and produce new tumors near the healthy tissues. Therefore, separating these invading cells and extracting cues from them is extremely important for determining the rate of cancer progression inside the body and for the development of individualized treatments, especially at the beginning of the metastasis process. The continuous and fast separation of CTCs has recently been achieved using numerous separation techniques, some of which involve multiple high-level operational protocols. Although a simple blood test can detect the presence of CTCs in the blood circulation system, the detection is still restricted due to the scarcity and heterogeneity of CTCs. The development of more reliable and effective techniques is thus highly desired. The technology of microfluidic devices is promising among many other bio-chemical and bio-physical technologies. This paper reviews recent developments in the two types of microfluidic devices, which are based on the size and/or density of cells, for separating cancer cells. The goal of this review is to identify knowledge or technology gaps and to suggest future works.
Collapse
Affiliation(s)
- Alireza Farahinia
- Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - Wenjun Zhang
- Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - Ildiko Badea
- College of Pharmacy and Nutrition, University of Saskatchewan, Saskatoon, SK S7N 5E5, Canada
| |
Collapse
|
42
|
Martín-Pérez A, Ramos D. Nanomechanical hydrodynamic force sensing using suspended microfluidic channels. MICROSYSTEMS & NANOENGINEERING 2023; 9:53. [PMID: 37168769 PMCID: PMC10164740 DOI: 10.1038/s41378-023-00531-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 03/24/2023] [Accepted: 03/28/2023] [Indexed: 05/13/2023]
Abstract
Microfluidics has demonstrated high versatility in the analysis of in-flow particles and can even achieve mechanical properties measurements of biological cells by applying hydrodynamic forces. However, there is currently no available technique that enables the direct measurement and tracking of these hydrodynamic forces acting on a flowing particle. In this work, we introduce a novel method for the direct measurement of the hydrodynamic force actuating on an in-flow particle based on the analysis of the induced resonance changes of suspended microchannel resonators (SMRs). This hydrodynamic force sensitivity depends on the device used; therefore, we considered the geometry and materials to advance this dependency on the SMR resonance frequency.
Collapse
Affiliation(s)
- Alberto Martín-Pérez
- Optomechanics Lab, Instituto de Ciencia de Materiales de Madrid (ICMM-CSIC), 3 Sor Juana Inés de la Cruz (Madrid), E-28049 Madrid, Spain
| | - Daniel Ramos
- Optomechanics Lab, Instituto de Ciencia de Materiales de Madrid (ICMM-CSIC), 3 Sor Juana Inés de la Cruz (Madrid), E-28049 Madrid, Spain
| |
Collapse
|
43
|
Zhou J, Vorobyeva A, Luan Q, Papautsky I. Single Cell Analysis of Inertial Migration by Circulating Tumor Cells and Clusters. MICROMACHINES 2023; 14:787. [PMID: 37421020 DOI: 10.3390/mi14040787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/23/2023] [Accepted: 03/27/2023] [Indexed: 07/09/2023]
Abstract
Single-cell analysis provides a wealth of information regarding the molecular landscape of the tumor cells responding to extracellular stimulations, which has greatly advanced the research in cancer biology. In this work, we adapt such a concept for the analysis of inertial migration of cells and clusters, which is promising for cancer liquid biopsy, by isolation and detection of circulating tumor cells (CTCs) and CTC clusters. Using high-speed camera tracking live individual tumor cells and cell clusters, the behavior of inertial migration was profiled in unprecedented detail. We found that inertial migration is heterogeneous spatially, depending on the initial cross-sectional location. The lateral migration velocity peaks at about 25% of the channel width away from the sidewalls for both single cells and clusters. More importantly, while the doublets of the cell clusters migrate significantly faster than single cells (~two times faster), cell triplets unexpectedly have similar migration velocities to doublets, which seemingly disagrees with the size-dependent nature of inertial migration. Further analysis indicates that the cluster shape or format (for example, triplets can be in string format or triangle format) plays a significant role in the migration of more complex cell clusters. We found that the migration velocity of a string triplet is statistically comparable to that of a single cell while the triangle triplets can migrate slightly faster than doublets, suggesting that size-based sorting of cells and clusters can be challenging depending on the cluster format. Undoubtedly, these new findings need to be considered in the translation of inertial microfluidic technology for CTC cluster detection.
Collapse
Affiliation(s)
- Jian Zhou
- Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL 60607, USA
- UI Cancer Center, University of Illinois Chicago, Chicago, IL 60607, USA
| | - Alexandra Vorobyeva
- Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL 60607, USA
| | - Qiyue Luan
- Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL 60607, USA
| | - Ian Papautsky
- Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL 60607, USA
- UI Cancer Center, University of Illinois Chicago, Chicago, IL 60607, USA
| |
Collapse
|
44
|
Saffari H, Hajiaghalou S, Hajari MA, Gourabi H, Fathi D, Fathi R. Design and fabrication of aspiration microfluidic channel for oocyte characterization. Talanta 2023; 254:124098. [PMID: 36462279 DOI: 10.1016/j.talanta.2022.124098] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Revised: 11/05/2022] [Accepted: 11/10/2022] [Indexed: 11/25/2022]
Abstract
The development potential for oocytes can be predicted by their mechanical properties. One important parameter that is measured to calculate oocyte hardness is Cortical Tension (CT). In this work, for the first time, we present the design, simulation, and fabrication of a new aspiration microfluidic chip to measure the CT of oocytes and then predict their maturation capability in the Germinal Vesicle (GV) stage. This high-performance technique facilitates oocyte characterization and is a promising alternative to traditional methods such as MicroPipette Aspiration (MPA). The proposed technique involves considerably simpler operation, less specialized equipment, and less technical skill than MPA. The proposed microfluidic channel also promises faster measurements. It is shown that in order to completely continue the growth process of oocytes in GV stage, the CT should be in a certain range: very low or very high CTs lead to unsuccessful growth. The obtained results show that 79% of oocytes with the CT between 1.5 and 3 nN/μm reach the Metaphase II (MII) stage, whereas the growth for 78% of oocytes with the CT less than 1.5 nN/μm or higher than 3 nN/μm stops at the GV or Germinal Vesicle Break Down (GVBD) stages. Another property, kvis, that points to the viscous behavior of oocytes is also measured. It is seen that 80% of GV oocytes with the kvis values between 15 and 30 k Pa s/m reach the MII stage.
Collapse
Affiliation(s)
- H Saffari
- Department of Electrical and Computer Engineering, Tarbiat Modares University (TMU), Tehran, Iran
| | - S Hajiaghalou
- Department of Embryology, Reproductive Biomedicine Research Center, Royan Institute for Reproductive Biomedicine, ACECR, Tehran, Iran
| | - M A Hajari
- Department of Cell Engineering, Cell Science Research Center, Royan Institute for Reproductive Biomedicine, ACECR, Tehran, Iran
| | - H Gourabi
- Department of Genetics, Reproductive Biomedicine Research Center, Royan Institute for Reproductive Biomedicine, ACECR, Tehran, Iran
| | - D Fathi
- Department of Electrical and Computer Engineering, Tarbiat Modares University (TMU), Tehran, Iran.
| | - R Fathi
- Department of Embryology, Reproductive Biomedicine Research Center, Royan Institute for Reproductive Biomedicine, ACECR, Tehran, Iran.
| |
Collapse
|
45
|
Hettiarachchi S, Cha H, Ouyang L, Mudugamuwa A, An H, Kijanka G, Kashaninejad N, Nguyen NT, Zhang J. Recent microfluidic advances in submicron to nanoparticle manipulation and separation. LAB ON A CHIP 2023; 23:982-1010. [PMID: 36367456 DOI: 10.1039/d2lc00793b] [Citation(s) in RCA: 17] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Manipulation and separation of submicron and nanoparticles are indispensable in many chemical, biological, medical, and environmental applications. Conventional technologies such as ultracentrifugation, ultrafiltration, size exclusion chromatography, precipitation and immunoaffinity capture are limited by high cost, low resolution, low purity or the risk of damage to biological particles. Microfluidics can accurately control fluid flow in channels with dimensions of tens of micrometres. Rapid microfluidics advancement has enabled precise sorting and isolating of nanoparticles with better resolution and efficiency than conventional technologies. This paper comprehensively studies the latest progress in microfluidic technology for submicron and nanoparticle manipulation. We first summarise the principles of the traditional techniques for manipulating nanoparticles. Following the classification of microfluidic techniques as active, passive, and hybrid approaches, we elaborate on the physics, device design, working mechanism and applications of each technique. We also compare the merits and demerits of different microfluidic techniques and benchmark them with conventional technologies. Concurrently, we summarise seven standard post-separation detection techniques for nanoparticles. Finally, we discuss current challenges and future perspectives on microfluidic technology for nanoparticle manipulation and separation.
Collapse
Affiliation(s)
- Samith Hettiarachchi
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Haotian Cha
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Lingxi Ouyang
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | | | - Hongjie An
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Gregor Kijanka
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Navid Kashaninejad
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Nam-Trung Nguyen
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Jun Zhang
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| |
Collapse
|
46
|
High-throughput isolation of cancer cells in spiral microchannel by changing the direction, magnitude and location of the maximum velocity. Sci Rep 2023; 13:3213. [PMID: 36828913 PMCID: PMC9958115 DOI: 10.1038/s41598-023-30275-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Accepted: 02/20/2023] [Indexed: 02/26/2023] Open
Abstract
Circulating tumor cells (CTCs) are scarce cancer cells that rarely spread from primary or metastatic tumors inside the patient's bloodstream. Determining the genetic characteristics of these paranormal cells provides significant data to guide cancer staging and treatment. Cell focusing using microfluidic chips has been implemented as an effective method for enriching CTCs. The distinct equilibrium positions of particles with different diameters across the microchannel width in the simulation showed that it was possible to isolate and concentrate breast cancer cells (BCCs) from WBCs at a moderate Reynolds number. Therefore we demonstrate high throughput isolation of BCCs using a passive, size-based, label-free microfluidic method based on hydrodynamic forces by an unconventional (combination of long loops and U-turn) spiral microfluidic device for isolating both CTCs and WBCs with high efficiency and purity (more than 90%) at a flow rate about 1.7 mL/min, which has a high throughput compared to similar ones. At this golden flow rate, up to 92% of CTCs were separated from the cell suspension. Its rapid processing time, simplicity, and potential ability to collect CTCs from large volumes of patient blood allow the practical use of this method in many applications.
Collapse
|
47
|
Recent advances in non-optical microfluidic platforms for bioparticle detection. Biosens Bioelectron 2023; 222:114944. [PMID: 36470061 DOI: 10.1016/j.bios.2022.114944] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 11/17/2022] [Accepted: 11/22/2022] [Indexed: 12/03/2022]
Abstract
The effective analysis of the basic structure and functional information of bioparticles are of great significance for the early diagnosis of diseases. The synergism between microfluidics and particle manipulation/detection technologies offers enhanced system integration capability and test accuracy for the detection of various bioparticles. Most microfluidic detection platforms are based on optical strategies such as fluorescence, absorbance, and image recognition. Although optical microfluidic platforms have proven their capabilities in the practical clinical detection of bioparticles, shortcomings such as expensive components and whole bulky devices have limited their practicality in the development of point-of-care testing (POCT) systems to be used in remote and underdeveloped areas. Therefore, there is an urgent need to develop cost-effective non-optical microfluidic platforms for bioparticle detection that can act as alternatives to optical counterparts. In this review, we first briefly summarise passive and active methods for bioparticle manipulation in microfluidics. Then, we survey the latest progress in non-optical microfluidic strategies based on electrical, magnetic, and acoustic techniques for bioparticle detection. Finally, a perspective is offered, clarifying challenges faced by current non-optical platforms in developing practical POCT devices and clinical applications.
Collapse
|
48
|
de Timary G, Rousseau CJ, Van Melderen L, Scheid B. Shear-enhanced sorting of ovoid and filamentous bacterial cells using pinch flow fractionation. LAB ON A CHIP 2023; 23:659-670. [PMID: 36562423 DOI: 10.1039/d2lc00969b] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
In this paper, we experimentally investigate the influence of the flow rate on the trajectory of ovoid and filamentous bacterial cells of E. coli in a low aspect ratio pinch flow fractionation device. To that aim, we vary the Reynolds number over two orders of magnitude, while monitoring the dynamics of the cells across our device. At low flow rates, filamentous cells adopt several rotational motions in the pinched segment, which are induced both by the shear rate and by their close interactions with the nearest wall. As a result, the geometrical centre of the filamentous cells deviates towards the centre of the channel, which increases their effective sorting diameter depending on the length of their major axis as well as on the rotational mode they adopt in the pinch. As the flow rate increases, particles are forced to align vertically in the pinch, in the direction of the main shear gradient, which reduces the amplitude of the lateral deviation generated by their rotation. The trajectory of the particles in the expansion is directly determined by their position at the pinch outlet. As a consequence, the position of the filamentous cells at the outlet of the device strongly depends on the flow rate as well as on the length of their major axis. Based on these observations we optimized the flow conditions to successfully extract an ultra high purity sample of filamentous cells from a solution containing mainly ovoid cells.
Collapse
Affiliation(s)
- Guillaume de Timary
- Transfers, Interfaces and Processes (TIPs) - ULB, C.P. 165/67, Brussels, Belgium.
| | | | | | - Benoit Scheid
- Transfers, Interfaces and Processes (TIPs) - ULB, C.P. 165/67, Brussels, Belgium.
| |
Collapse
|
49
|
Thurgood P, Needham S, Pirogova E, Peter K, Baratchi S, Khoshmanesh K. Dynamic Vortex Generation, Pulsed Injection, and Rapid Mixing of Blood Samples in Microfluidics Using the Tube Oscillation Mechanism. Anal Chem 2023; 95:3089-3097. [PMID: 36692453 DOI: 10.1021/acs.analchem.2c05456] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Here, we describe the generation of dynamic vortices in micro-scale cavities at low flow rates. The system utilizes a computer-controlled audio speaker to axially oscillate the inlet tube of the microfluidic system at desired frequencies and amplitudes. The oscillation of the tube induces transiently high flow rates in the system, which facilitates the generation of dynamic vortices inside the cavity. The size of the vortices can be modulated by varying the tube oscillation frequency or amplitude. The vortices can be generated in single or serial cavities and in a wide range of cavity sizes. We demonstrate the suitability of the tube oscillation mechanism for the pulsed injection of water-based solutions or whole blood into the cavity. The injection rate can be controlled by the oscillation characteristics of the tube, enabling the injection of liquids at ultralow flow rates. The dynamic vortices facilitate the rapid mixing of the injected liquid with the main flow. The controllability and versatility of this technology allow for the development of programmable inertial microfluidic systems for performing multistep biological assays.
Collapse
Affiliation(s)
- Peter Thurgood
- School of Engineering, RMIT University, Melbourne, Victoria3001, Australia
| | - Scott Needham
- Leading Technology Group, Camberwell, Victoria3124, Australia
| | - Elena Pirogova
- School of Engineering, RMIT University, Melbourne, Victoria3001, Australia
| | - Karlheinz Peter
- Baker Heart and Diabetes Institute, Melbourne, Victoria3004, Australia.,Department of Cardiometabolic Health, University of Melbourne, Parkville, Victoria3052, Australia
| | - Sara Baratchi
- School of Health & Biomedical Sciences, RMIT University, Bundoora, Victoria3082, Australia
| | | |
Collapse
|
50
|
Zhao Y, Isozaki A, Herbig M, Hayashi M, Hiramatsu K, Yamazaki S, Kondo N, Ohnuki S, Ohya Y, Nitta N, Goda K. Intelligent sort-timing prediction for image-activated cell sorting. Cytometry A 2023; 103:88-97. [PMID: 35766305 DOI: 10.1002/cyto.a.24664] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 05/20/2022] [Accepted: 06/11/2022] [Indexed: 02/07/2023]
Abstract
Intelligent image-activated cell sorting (iIACS) has enabled high-throughput image-based sorting of single cells with artificial intelligence (AI) algorithms. This AI-on-a-chip technology combines fluorescence microscopy, AI-based image processing, sort-timing prediction, and cell sorting. Sort-timing prediction is particularly essential due to the latency on the order of milliseconds between image acquisition and sort actuation, during which image processing is performed. The long latency amplifies the effects of the fluctuations in the flow speed of cells, leading to fluctuation and uncertainty in the arrival time of cells at the sort point on the microfluidic chip. To compensate for this fluctuation, iIACS measures the flow speed of each cell upstream, predicts the arrival timing of the cell at the sort point, and activates the actuation of the cell sorter appropriately. Here, we propose and demonstrate a machine learning technique to increase the accuracy of the sort-timing prediction that would allow for the improvement of sort event rate, yield, and purity. Specifically, we trained an algorithm to predict the sort timing for morphologically heterogeneous budding yeast cells. The algorithm we developed used cell morphology, position, and flow speed as inputs for prediction and achieved 41.5% lower prediction error compared to the previously employed method based solely on flow speed. As a result, our technique would allow for an increase in the sort event rate of iIACS by a factor of ~2.
Collapse
Affiliation(s)
- Yaqi Zhao
- Department of Chemistry, Graduate School of Science, The University of Tokyo, Tokyo, Japan
| | - Akihiro Isozaki
- Department of Chemistry, Graduate School of Science, The University of Tokyo, Tokyo, Japan
| | - Maik Herbig
- Department of Chemistry, Graduate School of Science, The University of Tokyo, Tokyo, Japan
| | - Mika Hayashi
- Department of Chemistry, Graduate School of Science, The University of Tokyo, Tokyo, Japan
| | - Kotaro Hiramatsu
- Department of Chemistry, Graduate School of Science, The University of Tokyo, Tokyo, Japan
| | - Sota Yamazaki
- Department of Chemistry, Graduate School of Science, The University of Tokyo, Tokyo, Japan
| | - Naoko Kondo
- Department of Integrated Biosciences, Graduate School of Frontier Sciences, The University of Tokyo, Chiba, Japan
| | - Shinsuke Ohnuki
- Department of Integrated Biosciences, Graduate School of Frontier Sciences, The University of Tokyo, Chiba, Japan
| | - Yoshikazu Ohya
- Department of Integrated Biosciences, Graduate School of Frontier Sciences, The University of Tokyo, Chiba, Japan.,Collaborative Research Institute for Innovative Microbiology, The University of Tokyo, Tokyo, Japan
| | | | - Keisuke Goda
- Department of Chemistry, Graduate School of Science, The University of Tokyo, Tokyo, Japan.,CYBO, Tokyo, Japan.,Department of Bioengineering, University of California, California, Los Angeles, USA.,Institute of Technological Sciences, Wuhan University, Hubei, China
| |
Collapse
|