1
|
Afnan J, Cai Z, Lina JM, Abdallah C, Delaire E, Avigdor T, Ros V, Hedrich T, von Ellenrieder N, Kobayashi E, Frauscher B, Gotman J, Grova C. EEG/MEG source imaging of deep brain activity within the maximum entropy on the mean framework: Simulations and validation in epilepsy. Hum Brain Mapp 2024; 45:e26720. [PMID: 38994740 PMCID: PMC11240147 DOI: 10.1002/hbm.26720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 04/16/2024] [Accepted: 05/06/2024] [Indexed: 07/13/2024] Open
Abstract
Electro/Magneto-EncephaloGraphy (EEG/MEG) source imaging (EMSI) of epileptic activity from deep generators is often challenging due to the higher sensitivity of EEG/MEG to superficial regions and to the spatial configuration of subcortical structures. We previously demonstrated the ability of the coherent Maximum Entropy on the Mean (cMEM) method to accurately localize the superficial cortical generators and their spatial extent. Here, we propose a depth-weighted adaptation of cMEM to localize deep generators more accurately. These methods were evaluated using realistic MEG/high-density EEG (HD-EEG) simulations of epileptic activity and actual MEG/HD-EEG recordings from patients with focal epilepsy. We incorporated depth-weighting within the MEM framework to compensate for its preference for superficial generators. We also included a mesh of both hippocampi, as an additional deep structure in the source model. We generated 5400 realistic simulations of interictal epileptic discharges for MEG and HD-EEG involving a wide range of spatial extents and signal-to-noise ratio (SNR) levels, before investigating EMSI on clinical HD-EEG in 16 patients and MEG in 14 patients. Clinical interictal epileptic discharges were marked by visual inspection. We applied three EMSI methods: cMEM, depth-weighted cMEM and depth-weighted minimum norm estimate (MNE). The ground truth was defined as the true simulated generator or as a drawn region based on clinical information available for patients. For deep sources, depth-weighted cMEM improved the localization when compared to cMEM and depth-weighted MNE, whereas depth-weighted cMEM did not deteriorate localization accuracy for superficial regions. For patients' data, we observed improvement in localization for deep sources, especially for the patients with mesial temporal epilepsy, for which cMEM failed to reconstruct the initial generator in the hippocampus. Depth weighting was more crucial for MEG (gradiometers) than for HD-EEG. Similar findings were found when considering depth weighting for the wavelet extension of MEM. In conclusion, depth-weighted cMEM improved the localization of deep sources without or with minimal deterioration of the localization of the superficial sources. This was demonstrated using extensive simulations with MEG and HD-EEG and clinical MEG and HD-EEG for epilepsy patients.
Collapse
Affiliation(s)
- Jawata Afnan
- Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Montréal, Québec, Canada
- Integrated Program in Neuroscience, McGill University, Montréal, Québec, Canada
- Montreal Neurological Institute, Department of Neurology and Neurosurgery, McGill University, Montréal, Québec, Canada
| | - Zhengchen Cai
- Montreal Neurological Institute, Department of Neurology and Neurosurgery, McGill University, Montréal, Québec, Canada
| | - Jean-Marc Lina
- Physnum Team, Centre De Recherches Mathématiques, Montréal, Québec, Canada
- Electrical Engineering Department, École De Technologie Supérieure, Montréal, Québec, Canada
- Center for Advanced Research in Sleep Medicine, Sacré-Coeur Hospital, Montréal, Québec, Canada
| | - Chifaou Abdallah
- Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Montréal, Québec, Canada
- Integrated Program in Neuroscience, McGill University, Montréal, Québec, Canada
- Analytical Neurophysiology Lab, Department of Neurology, Duke University School of Medicine, Durham, North Carolina, USA
| | - Edouard Delaire
- Multimodal Functional Imaging Lab, Department of Physics and Concordia School of Health, Concordia University, Montréal, Québec, Canada
| | - Tamir Avigdor
- Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Montréal, Québec, Canada
- Integrated Program in Neuroscience, McGill University, Montréal, Québec, Canada
- Analytical Neurophysiology Lab, Department of Neurology, Duke University School of Medicine, Durham, North Carolina, USA
| | - Victoria Ros
- Montreal Neurological Institute, Department of Neurology and Neurosurgery, McGill University, Montréal, Québec, Canada
| | - Tanguy Hedrich
- Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Montréal, Québec, Canada
| | - Nicolas von Ellenrieder
- Montreal Neurological Institute, Department of Neurology and Neurosurgery, McGill University, Montréal, Québec, Canada
| | - Eliane Kobayashi
- Montreal Neurological Institute, Department of Neurology and Neurosurgery, McGill University, Montréal, Québec, Canada
| | - Birgit Frauscher
- Montreal Neurological Institute, Department of Neurology and Neurosurgery, McGill University, Montréal, Québec, Canada
- Analytical Neurophysiology Lab, Department of Neurology, Duke University School of Medicine, Durham, North Carolina, USA
| | - Jean Gotman
- Montreal Neurological Institute, Department of Neurology and Neurosurgery, McGill University, Montréal, Québec, Canada
| | - Christophe Grova
- Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Montréal, Québec, Canada
- Montreal Neurological Institute, Department of Neurology and Neurosurgery, McGill University, Montréal, Québec, Canada
- Physnum Team, Centre De Recherches Mathématiques, Montréal, Québec, Canada
- Multimodal Functional Imaging Lab, Department of Physics and Concordia School of Health, Concordia University, Montréal, Québec, Canada
| |
Collapse
|
2
|
Ye S, Bagić A, He B. Disentanglement of Resting State Brain Networks for Localizing Epileptogenic Zone in Focal Epilepsy. Brain Topogr 2024; 37:152-168. [PMID: 38112884 PMCID: PMC10771380 DOI: 10.1007/s10548-023-01025-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 11/20/2023] [Indexed: 12/21/2023]
Abstract
The objective of this study is to extract pathological brain networks from interictal period of E/MEG recordings to localize epileptic foci for presurgical evaluation. We proposed here a resting state E/MEG analysis framework, to disentangle brain functional networks represented by neural oscillations. By using an Embedded Hidden Markov Model, we constructed a state space for resting state recordings consisting of brain states with different spatiotemporal patterns. Functional connectivity analysis along with graph theory was applied on the extracted brain states to quantify the network features of the extracted brain states, based on which the source location of pathological states is determined. The method is evaluated by computer simulations and our simulation results revealed the proposed framework can extract brain states with high accuracy regarding both spatial and temporal profiles. We further evaluated the framework as compared with intracranial EEG defined seizure onset zone in 10 patients with drug-resistant focal epilepsy who underwent MEG recordings and were seizure free after surgical resection. The real patient data analysis showed very good localization results using the extracted pathological brain states in 6/10 patients, with localization error of about 15 mm as compared to the seizure onset zone. We show that the pathological brain networks can be disentangled from the resting-state electromagnetic recording and could be identified based on the connectivity features. The framework can serve as a useful tool in extracting brain functional networks from noninvasive resting state electromagnetic recordings, and promises to offer an alternative to aid presurgical evaluation guiding intracranial EEG electrodes implantation.
Collapse
Affiliation(s)
- Shuai Ye
- Department of Biomedical Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213, USA
| | - Anto Bagić
- Department of Neurology, University of Pittsburgh Comprehensive Epilepsy Center (UPCEC), University of Pittsburgh Medical School, Pittsburgh, PA, USA
| | - Bin He
- Department of Biomedical Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213, USA.
| |
Collapse
|
3
|
Horrillo-Maysonnial A, Avigdor T, Abdallah C, Mansilla D, Thomas J, von Ellenrieder N, Royer J, Bernhardt B, Grova C, Gotman J, Frauscher B. Targeted density electrode placement achieves high concordance with traditional high-density EEG for electrical source imaging in epilepsy. Clin Neurophysiol 2023; 156:262-271. [PMID: 37704552 DOI: 10.1016/j.clinph.2023.08.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 07/27/2023] [Accepted: 08/12/2023] [Indexed: 09/15/2023]
Abstract
OBJECTIVE High-density (HD) electroencephalography (EEG) is increasingly used in presurgical epilepsy evaluation, but it is demanding in time and resources. To overcome these issues, we compared EEG source imaging (ESI) solutions with a targeted density and HD-EEG montage. METHODS HD-EEGs from patients undergoing presurgical evaluation were analyzed. A low-density recording was created by selecting the 25 electrodes of a standard montage from the 83 electrodes of the HD-EEG and adding 8-11 electrodes around the electrode with the highest amplitude interictal epileptiform discharges. The ESI solution from this "targeted" montage was compared to that from the HD-EEG using the distance between peak vertices, sublobar concordance and a qualitative similarity measure. RESULTS Fifty-eight foci of forty-three patients were included. The median distance between the peak vertices of the two montages was 13.2 mm, irrespective of focus' location. Tangential generators (n = 5/58) showed a higher distance than radial generators (p = 0.04). We found sublobar concordance in 54/58 of the foci (93%). Map similarity, assessed by an epileptologist, had a median score of 4/5. CONCLUSIONS ESI solutions obtained from a targeted density montage show high concordance with those calculated from HD-EEG. SIGNIFICANCE Requiring significantly fewer electrodes, targeted density EEG allows obtaining similar ESI solutions as traditional HD-EEG montage.
Collapse
Affiliation(s)
- A Horrillo-Maysonnial
- Clinical Neurophysiology Section, Clínica Universidad de Navarra, Pamplona, Spain; IdiSNA, Instituto de Investigación Sanitaria de Navarra, Pamplona, Spain; Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada
| | - T Avigdor
- Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Canada.
| | - C Abdallah
- Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Canada.
| | - D Mansilla
- Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada.
| | - J Thomas
- Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada.
| | - N von Ellenrieder
- Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada.
| | - J Royer
- Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Multimodal Imaging and Connectome Analysis Laboratory, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada.
| | - B Bernhardt
- Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Multimodal Imaging and Connectome Analysis Laboratory, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada.
| | - C Grova
- Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Canada; Multimodal Functional Imaging Lab, PERFORM Center, Department of Physics, Concordia University, Montreal, QC, Canada.
| | - J Gotman
- Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada.
| | - B Frauscher
- Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Department of Neurology, Duke University Medical Center, Durham, NC, United States; Department of Biomedical Engineering, Duke Pratt School of Engineering, Durham, NC, United States.
| |
Collapse
|
4
|
Anand A, Magnotti JF, Smith DN, Gadot R, Najera RA, Hegazy MIR, Gavvala JR, Shofty B, Sheth SA. Predictive value of magnetoencephalography in guiding the intracranial implant strategy for intractable epilepsy. J Neurosurg 2022; 137:1237-1247. [PMID: 35303696 DOI: 10.3171/2022.1.jns212943] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Accepted: 01/31/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Magnetoencephalography (MEG) is a useful component of the presurgical evaluation of patients with epilepsy. Due to its high spatiotemporal resolution, MEG often provides additional information to the clinician when forming hypotheses about the epileptogenic zone (EZ). Because of the increasing utilization of stereo-electroencephalography (sEEG), MEG clusters are used to guide sEEG electrode targeting with increasing frequency. However, there are no predefined features of an MEG cluster that predict ictal activity. This study aims to determine which MEG cluster characteristics are predictive of the EZ. METHODS The authors retrospectively analyzed all patients who had an MEG study (2017-2021) and underwent subsequent sEEG evaluation. MEG dipoles and sEEG electrodes were reconstructed in the same coordinate space to calculate overlap among individual contacts on electrodes and MEG clusters. MEG cluster features-including number of dipoles, proximity, angle, density, magnitude, confidence parameters, and brain region-were used to predict ictal activity in sEEG. Logistic regression was used to identify important cluster features and to train a binary classifier to predict ictal activity. RESULTS Across 40 included patients, 196 electrodes (42.2%) sampled MEG clusters. Electrodes that sampled MEG clusters had higher rates of ictal and interictal activity than those that did not sample MEG clusters (ictal 68.4% vs 39.8%, p < 0.001; interictal 71.9% vs 44.6%, p < 0.001). Logistic regression revealed that the number of dipoles (odds ratio [OR] 1.09, 95% confidence interval [CI] 1.04-1.14, t = 3.43) and confidence volume (OR 0.02, 95% CI 0.00-0.86, t = -2.032) were predictive of ictal activity. This model was predictive of ictal activity with 77.3% accuracy (sensitivity = 80%, specificity = 74%, C-statistic = 0.81). Using only the number of dipoles had a predictive accuracy of 75%, whereas a threshold between 14 and 17 dipoles in a cluster detected ictal activity with 75.9%-85.2% sensitivity. CONCLUSIONS MEG clusters with approximately 14 or more dipoles are strong predictors of ictal activity and may be useful in the preoperative planning of sEEG implantation.
Collapse
Affiliation(s)
| | - John F Magnotti
- 2Department of Neurosurgery, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania
| | | | | | | | | | - Jay R Gavvala
- 3Neurology, Baylor College of Medicine, Houston, Texas; and
| | | | | |
Collapse
|
5
|
Xie M, Wang X, Qiao J, Zhou J, Guan Y, Liu C, Zhao M, Li T, Luan G. The long-term surgical outcomes of low-grade epilepsy-associated neuroepithelial tumors. Epilepsia Open 2022; 7:697-709. [PMID: 36081402 PMCID: PMC9712488 DOI: 10.1002/epi4.12648] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 09/05/2022] [Indexed: 12/30/2022] Open
Abstract
OBJECTIVE This study aimed to evaluate the surgical outcomes and relevant prognostic factors in patients with low-grade epilepsy-associated neuroepithelial tumors (LEAT) and, especially, to develop a scoring system to predict postoperative seizure outcomes. METHODS The clinical data of patients who underwent epilepsy surgery for LEAT were retrospectively studied. The surgical outcomes of seizure and neurological statuses in patients were evaluated using Engel classification and modified Rankin Scale (mRS) scoring, respectively. A scoring system of seizure outcomes was constructed based on the weight of the β-coefficient estimate of each predictor in the final multivariate predicting model of seizure outcomes. RESULTS Of the 287 patients (106 female) enrolled, the median age was 19 years at surgery and 10 years at seizure onset, with a median duration of epilepsy of 60 months. Among 258 patients who were followed up for at least 12 months, 215 (83.3%) patients had a favorable seizure outcome (Engel class I) after surgery, and 43 (16.7%) patients had an unfavorable seizure outcome; longer duration of epilepsy, discordant magnetoencephalography (MEG) findings, and acute postoperative seizures were significantly included in the scoring system to predict unfavorable seizure outcomes, and in the scoring system, accumulated scoring of 0-19 scores was recorded, which were finally grouped into three risk levels: low risk (risk < 30%), medium risk (30% ≤ risk < 70%), and high risk (risk ≥ 70%). In addition, favorable neurological outcomes (mRS score 0-1) were recorded in 187 (72.5%) patients, while unfavorable neurological outcomes were recorded in 71 (27.5%) patients, which were significantly related to poor seizure control, older age at surgery, and longer duration of epilepsy and hospitalization time. SIGNIFICANCE The long-term surgical outcomes of LEAT after surgery were satisfactory. A scoring system for predicting unfavorable seizure outcomes with different risk levels was developed, which could partly guide clinical treatments of LEAT.
Collapse
Affiliation(s)
- Ming‐Guo Xie
- Department of Neurosurgery, Epilepsy Center, Sanbo Brain HospitalCapital Medical UniversityBeijingChina,Beijing Key Laboratory of Epilepsy, Sanbo Brain HospitalCapital Medical UniversityBeijingChina
| | - Xiong‐Fei Wang
- Department of Neurosurgery, Epilepsy Center, Sanbo Brain HospitalCapital Medical UniversityBeijingChina,Beijing Key Laboratory of Epilepsy, Sanbo Brain HospitalCapital Medical UniversityBeijingChina
| | - Jiao Qiao
- Department of Neurosurgery, Epilepsy Center, Sanbo Brain HospitalCapital Medical UniversityBeijingChina,Beijing Key Laboratory of Epilepsy, Sanbo Brain HospitalCapital Medical UniversityBeijingChina
| | - Jian Zhou
- Department of Neurosurgery, Epilepsy Center, Sanbo Brain HospitalCapital Medical UniversityBeijingChina,Beijing Key Laboratory of Epilepsy, Sanbo Brain HospitalCapital Medical UniversityBeijingChina
| | - Yu‐Guang Guan
- Department of Neurosurgery, Epilepsy Center, Sanbo Brain HospitalCapital Medical UniversityBeijingChina,Beijing Key Laboratory of Epilepsy, Sanbo Brain HospitalCapital Medical UniversityBeijingChina
| | - Chang‐Qing Liu
- Department of Neurosurgery, Epilepsy Center, Sanbo Brain HospitalCapital Medical UniversityBeijingChina,Beijing Key Laboratory of Epilepsy, Sanbo Brain HospitalCapital Medical UniversityBeijingChina
| | - Meng Zhao
- Department of Neurosurgery, Epilepsy Center, Sanbo Brain HospitalCapital Medical UniversityBeijingChina,Beijing Key Laboratory of Epilepsy, Sanbo Brain HospitalCapital Medical UniversityBeijingChina
| | - Tian‐Fu Li
- Beijing Key Laboratory of Epilepsy, Sanbo Brain HospitalCapital Medical UniversityBeijingChina,Beijing Institute for Brain DisordersCapital Medical UniversityBeijingChina,Department of Neurology, Epilepsy Center, Sanbo Brain HospitalCapital Medical UniversityBeijingChina
| | - Guo‐Ming Luan
- Department of Neurosurgery, Epilepsy Center, Sanbo Brain HospitalCapital Medical UniversityBeijingChina,Beijing Key Laboratory of Epilepsy, Sanbo Brain HospitalCapital Medical UniversityBeijingChina,Beijing Institute for Brain DisordersCapital Medical UniversityBeijingChina
| |
Collapse
|
6
|
Ricci L, Matarrese M, Peters JM, Tamilia E, Madsen JR, Pearl PL, Papadelis C. Virtual implantation using conventional scalp EEG delineates seizure onset and predicts surgical outcome in children with epilepsy. Clin Neurophysiol 2022; 139:49-57. [PMID: 35526353 PMCID: PMC10026594 DOI: 10.1016/j.clinph.2022.04.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Revised: 04/04/2022] [Accepted: 04/08/2022] [Indexed: 11/16/2022]
Abstract
OBJECTIVE Delineation of the seizure onset zone (SOZ) is required in children with drug resistant epilepsy (DRE) undergoing neurosurgery. Intracranial EEG (icEEG) serves as gold standard but has limitations. Here, we examine the utility of virtual implantation with electrical source imaging (ESI) on ictal scalp EEG for mapping the SOZ and predict surgical outcome. METHODS We retrospectively analyzed EEG data from 35 children with DRE who underwent surgery and dichotomized into seizure-free (SF) and non-seizure-free (NSF). We estimated virtual sensors (VSs) at brain locations that matched icEEG implantation and compared ictal patterns at VSs vs icEEG. We calculated the agreement between VSs SOZ and clinically defined SOZ and built receiver operating characteristic (ROC) curves to test whether it predicted outcome. RESULTS Twenty-one patients were SF after surgery. Moderate agreement between virtual and icEEG patterns was observed (kappa = 0.45, p < 0.001). Virtual SOZ agreement with clinically defined SOZ was higher in SF vs NSF patients (66.6% vs 41.6%, p = 0.01). Anatomical concordance of virtual SOZ with clinically defined SOZ predicted outcome (AUC = 0.73; 95% CI: 0.57-0.89; sensitivity = 66.7%; specificity = 78.6%; accuracy = 71.4%). CONCLUSIONS Virtual implantation on ictal scalp EEG can approximate the SOZ and predict outcome. SIGNIFICANCE SOZ mapping with VSs may contribute to tailoring icEEG implantation and predict outcome.
Collapse
Affiliation(s)
- Lorenzo Ricci
- Unit of Neurology, Neurophysiology, Neurobiology, Department of Medicine, University Campus Bio-Medico of Rome, Rome, Italy
| | - Margherita Matarrese
- Unit of Non-Linear Physics and Mathematical Modelling, Engineering Department, University Campus Bio-Medico of Rome, Rome, Italy; Jane and John Justin Neurosciences Center, Cook Children's Health Care System, Fort Worth, TX, USA; Department of Bioengineering, University of Texas at Arlington, Arlington, TX, USA
| | - Jurriaan M Peters
- Division of Epilepsy and Clinical Neurophysiology, Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Eleonora Tamilia
- Division of Newborn Medicine, Department of Medicine, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Joseph R Madsen
- Division of Epilepsy Surgery, Department of Neurosurgery, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Phillip L Pearl
- Division of Epilepsy and Clinical Neurophysiology, Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Christos Papadelis
- Jane and John Justin Neurosciences Center, Cook Children's Health Care System, Fort Worth, TX, USA; Department of Bioengineering, University of Texas at Arlington, Arlington, TX, USA; School of Medicine, Texas Christian University, Fort Worth, TX, USA.
| |
Collapse
|
7
|
Abdallah C, Hedrich T, Koupparis A, Afnan J, Hall JA, Gotman J, Dubeau F, von Ellenrieder N, Frauscher B, Kobayashi E, Grova C. Clinical Yield of Electromagnetic Source Imaging and Hemodynamic Responses in Epilepsy: Validation With Intracerebral Data. Neurology 2022; 98:e2499-e2511. [PMID: 35473762 PMCID: PMC9231837 DOI: 10.1212/wnl.0000000000200337] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2021] [Accepted: 02/21/2022] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND AND OBJECTIVES Accurate delineation of the seizure-onset zone (SOZ) in focal drug-resistant epilepsy often requires stereo-EEG (SEEG) recordings. Our aims were to propose a truly objective and quantitative comparison between EEG/magnetoencephalography (MEG) source imaging (EMSI), EEG/fMRI responses for similar spikes with primary irritative zone (PIZ) and SOZ defined by SEEG and to evaluate the value of EMSI and EEG/fMRI to predict postsurgical outcome. METHODS We identified patients with drug-resistant epilepsy who underwent EEG/MEG, EEG/fMRI, and subsequent SEEG at the Epilepsy Service from the Montreal Neurological Institute and Hospital. We quantified multimodal concordance within the SEEG channel space as spatial overlap with PIZ/SOZ and distances to the spike-onset, spike maximum amplitude and seizure core intracerebral channels by applying a new methodology consisting of converting EMSI results into SEEG electrical potentials (EMSIe-SEEG) and projecting the most significant fMRI response on the SEEG channels (fMRIp-SEEG). Spatial overlaps with PIZ/SOZ (AUCPIZ, AUCSOZ) were assessed by using the area under the receiver operating characteristic curve (AUC). Here, AUC represents the probability that a randomly picked active contact exhibited higher amplitude when located inside the spatial reference than outside. RESULTS Seventeen patients were included. Mean spatial overlaps with the PIZ and SOZ were 0.71 and 0.65 for EMSIe-SEEG and 0.57 and 0.62 for fMRIp-SEEG. Good EMSIe-SEEG spatial overlap with the PIZ was associated with smaller distance from the maximum EMSIe-SEEG contact to the spike maximum amplitude channel (median distance 14 mm). Conversely, good fMRIp-SEEG spatial overlap with the SOZ was associated with smaller distances from the maximum fMRIp-SEEG contact to the spike-onset and seizure core channels (median distances 10 and 5 mm, respectively). Surgical outcomes were correctly predicted by EEG/MEG in 12 of 15 (80%) patients and EEG/fMRI in 6 of 11(54%) patients. DISCUSSION With the use of a unique quantitative approach estimating EMSI and fMRI results in the reference SEEG channel space, EEG/MEG and EEG/fMRI accurately localized the SOZ and the PIZ. Precisely, EEG/MEG more accurately localized the PIZ, whereas EEG/fMRI was more sensitive to the SOZ. Both neuroimaging techniques provide complementary localization that can help guide SEEG implantation and select good candidates for surgery.
Collapse
Affiliation(s)
- Chifaou Abdallah
- From the Multimodal Functional Imaging Lab (C.A., T.H., J.A., C.G.), Biomedical Engineering Department, Montreal Neurological Institute and Hospital (C.A., A.K., J.A., J.A.H., J.G., F.D., N.v.E., B.F., E.K., C.G.), Neurology and Neurosurgery Department, and Analytical Neurophysiology Lab (T.H., B.F.), McGill University; and Multimodal Functional Imaging Lab (C.G.), PERFORM Centre, Department of Physics, Concordia University, Montreal, Quebec, Canada.
| | - Tanguy Hedrich
- From the Multimodal Functional Imaging Lab (C.A., T.H., J.A., C.G.), Biomedical Engineering Department, Montreal Neurological Institute and Hospital (C.A., A.K., J.A., J.A.H., J.G., F.D., N.v.E., B.F., E.K., C.G.), Neurology and Neurosurgery Department, and Analytical Neurophysiology Lab (T.H., B.F.), McGill University; and Multimodal Functional Imaging Lab (C.G.), PERFORM Centre, Department of Physics, Concordia University, Montreal, Quebec, Canada
| | - Andreas Koupparis
- From the Multimodal Functional Imaging Lab (C.A., T.H., J.A., C.G.), Biomedical Engineering Department, Montreal Neurological Institute and Hospital (C.A., A.K., J.A., J.A.H., J.G., F.D., N.v.E., B.F., E.K., C.G.), Neurology and Neurosurgery Department, and Analytical Neurophysiology Lab (T.H., B.F.), McGill University; and Multimodal Functional Imaging Lab (C.G.), PERFORM Centre, Department of Physics, Concordia University, Montreal, Quebec, Canada
| | - Jawata Afnan
- From the Multimodal Functional Imaging Lab (C.A., T.H., J.A., C.G.), Biomedical Engineering Department, Montreal Neurological Institute and Hospital (C.A., A.K., J.A., J.A.H., J.G., F.D., N.v.E., B.F., E.K., C.G.), Neurology and Neurosurgery Department, and Analytical Neurophysiology Lab (T.H., B.F.), McGill University; and Multimodal Functional Imaging Lab (C.G.), PERFORM Centre, Department of Physics, Concordia University, Montreal, Quebec, Canada
| | - Jeffrey Alan Hall
- From the Multimodal Functional Imaging Lab (C.A., T.H., J.A., C.G.), Biomedical Engineering Department, Montreal Neurological Institute and Hospital (C.A., A.K., J.A., J.A.H., J.G., F.D., N.v.E., B.F., E.K., C.G.), Neurology and Neurosurgery Department, and Analytical Neurophysiology Lab (T.H., B.F.), McGill University; and Multimodal Functional Imaging Lab (C.G.), PERFORM Centre, Department of Physics, Concordia University, Montreal, Quebec, Canada
| | - Jean Gotman
- From the Multimodal Functional Imaging Lab (C.A., T.H., J.A., C.G.), Biomedical Engineering Department, Montreal Neurological Institute and Hospital (C.A., A.K., J.A., J.A.H., J.G., F.D., N.v.E., B.F., E.K., C.G.), Neurology and Neurosurgery Department, and Analytical Neurophysiology Lab (T.H., B.F.), McGill University; and Multimodal Functional Imaging Lab (C.G.), PERFORM Centre, Department of Physics, Concordia University, Montreal, Quebec, Canada
| | - Francois Dubeau
- From the Multimodal Functional Imaging Lab (C.A., T.H., J.A., C.G.), Biomedical Engineering Department, Montreal Neurological Institute and Hospital (C.A., A.K., J.A., J.A.H., J.G., F.D., N.v.E., B.F., E.K., C.G.), Neurology and Neurosurgery Department, and Analytical Neurophysiology Lab (T.H., B.F.), McGill University; and Multimodal Functional Imaging Lab (C.G.), PERFORM Centre, Department of Physics, Concordia University, Montreal, Quebec, Canada
| | - Nicolas von Ellenrieder
- From the Multimodal Functional Imaging Lab (C.A., T.H., J.A., C.G.), Biomedical Engineering Department, Montreal Neurological Institute and Hospital (C.A., A.K., J.A., J.A.H., J.G., F.D., N.v.E., B.F., E.K., C.G.), Neurology and Neurosurgery Department, and Analytical Neurophysiology Lab (T.H., B.F.), McGill University; and Multimodal Functional Imaging Lab (C.G.), PERFORM Centre, Department of Physics, Concordia University, Montreal, Quebec, Canada
| | - Birgit Frauscher
- From the Multimodal Functional Imaging Lab (C.A., T.H., J.A., C.G.), Biomedical Engineering Department, Montreal Neurological Institute and Hospital (C.A., A.K., J.A., J.A.H., J.G., F.D., N.v.E., B.F., E.K., C.G.), Neurology and Neurosurgery Department, and Analytical Neurophysiology Lab (T.H., B.F.), McGill University; and Multimodal Functional Imaging Lab (C.G.), PERFORM Centre, Department of Physics, Concordia University, Montreal, Quebec, Canada
| | - Eliane Kobayashi
- From the Multimodal Functional Imaging Lab (C.A., T.H., J.A., C.G.), Biomedical Engineering Department, Montreal Neurological Institute and Hospital (C.A., A.K., J.A., J.A.H., J.G., F.D., N.v.E., B.F., E.K., C.G.), Neurology and Neurosurgery Department, and Analytical Neurophysiology Lab (T.H., B.F.), McGill University; and Multimodal Functional Imaging Lab (C.G.), PERFORM Centre, Department of Physics, Concordia University, Montreal, Quebec, Canada
| | - Christophe Grova
- From the Multimodal Functional Imaging Lab (C.A., T.H., J.A., C.G.), Biomedical Engineering Department, Montreal Neurological Institute and Hospital (C.A., A.K., J.A., J.A.H., J.G., F.D., N.v.E., B.F., E.K., C.G.), Neurology and Neurosurgery Department, and Analytical Neurophysiology Lab (T.H., B.F.), McGill University; and Multimodal Functional Imaging Lab (C.G.), PERFORM Centre, Department of Physics, Concordia University, Montreal, Quebec, Canada
| |
Collapse
|
8
|
Zhang C, Liu W, Zhang J, Zhang X, Huang P, Sun B, Zhan S, Cao C. Utility of magnetoencephalography combined with stereo-electroencephalography in resective epilepsy surgery: a 2-year follow-up. Seizure 2022; 97:94-101. [DOI: 10.1016/j.seizure.2022.03.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 03/14/2022] [Accepted: 03/16/2022] [Indexed: 11/25/2022] Open
|
9
|
High-resolution electric source imaging for presurgical evaluation of tuberous sclerosis complex patients. Clin Neurophysiol 2021; 133:126-134. [PMID: 34844043 DOI: 10.1016/j.clinph.2021.09.020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 08/26/2021] [Accepted: 09/18/2021] [Indexed: 11/22/2022]
Abstract
OBJECTIVE We retrospectively assessed the localizing value of patient-history-based semiology (PHS), video-based semiology (VS), long-term monitoring video electroencephalography (LTM-VEEG) and interictal high resolution electric source imaging (HR-ESI) in the presurgical workup of patients with tuberous sclerosis complex (TSC). METHODS Data from 24 consecutive TSC surgical candidates who underwent both HR-ESI and LTM-VEEG was retrospectively collected. PHS and VS were analyzed to hypothesize the symptomatogenic zone localization. LTM-VEEG and HR-ESI localization results were extracted from the diagnostic reports. Localizing value was compared between modalities, taken the resected/disconnected area of surgical patients in consideration. HR-ESI's impact on the epileptogenic zone hypothesis and surgical workup was evaluated. RESULTS Semiology, interictal EEG, ictal EEG and HR-ESI were localizing in 25%, 54%, 63% and 79% of patients. Inter-modality concordance ranged between 33-89%. In good surgical outcome patients, PHS, VS, interictal EEG, ictal EEG and HR-ESI showed concordance with resected area in 1/9 (11%), 0/9 (0%), 4/9 (44%), 3/9 (33%) and 6/9 patients (67%). HR-ESI positively impacts clinical management in 50% of patients. CONCLUSIONS In presurgical evaluation of TSC patients, semiology often has limited localizing value. Presurgical work-up benefits from HR-ESI. SIGNIFICANCE Our findings may advice future presurgical epilepsy workup of TSC patients with the ultimate aim to improve outcome.
Collapse
|
10
|
Jiang X, Ye S, Sohrabpour A, Bagić A, He B. Imaging the extent and location of spatiotemporally distributed epileptiform sources from MEG measurements. Neuroimage Clin 2021; 33:102903. [PMID: 34864288 PMCID: PMC8648830 DOI: 10.1016/j.nicl.2021.102903] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 11/26/2021] [Accepted: 11/27/2021] [Indexed: 11/23/2022]
Abstract
Non-invasive MEG/EEG source imaging provides valuable information about the epileptogenic brain areas which can be used to aid presurgical planning in focal epilepsy patients suffering from drug-resistant seizures. However, the source extent estimation for electrophysiological source imaging remains to be a challenge and is usually largely dependent on subjective choice. Our recently developed algorithm, fast spatiotemporal iteratively reweighted edge sparsity minimization (FAST-IRES) strategy, has been shown to objectively estimate extended sources from EEG recording, while it has not been applied to MEG recordings. In this work, through extensive numerical experiments and real data analysis in a group of focal drug-resistant epilepsy patients' interictal spikes, we demonstrated the ability of FAST-IRES algorithm to image the location and extent of underlying epilepsy sources from MEG measurements. Our results indicate the merits of FAST-IRES in imaging the location and extent of epilepsy sources for pre-surgical evaluation from MEG measurements.
Collapse
Affiliation(s)
- Xiyuan Jiang
- Department of Biomedical Engineering, Carnegie Mellon University, USA
| | - Shuai Ye
- Department of Biomedical Engineering, Carnegie Mellon University, USA
| | - Abbas Sohrabpour
- Department of Biomedical Engineering, Carnegie Mellon University, USA
| | - Anto Bagić
- University of Pittsburgh Comprehensive Epilepsy Center (UPCEC), University of Pittsburgh Medical School, USA
| | - Bin He
- Department of Biomedical Engineering, Carnegie Mellon University, USA.
| |
Collapse
|
11
|
Laohathai C, Ebersole JS, Mosher JC, Bagić AI, Sumida A, Von Allmen G, Funke ME. Practical Fundamentals of Clinical MEG Interpretation in Epilepsy. Front Neurol 2021; 12:722986. [PMID: 34721261 PMCID: PMC8551575 DOI: 10.3389/fneur.2021.722986] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Accepted: 09/06/2021] [Indexed: 11/29/2022] Open
Abstract
Magnetoencephalography (MEG) is a neurophysiologic test that offers a functional localization of epileptic sources in patients considered for epilepsy surgery. The understanding of clinical MEG concepts, and the interpretation of these clinical studies, are very involving processes that demand both clinical and procedural expertise. One of the major obstacles in acquiring necessary proficiency is the scarcity of fundamental clinical literature. To fill this knowledge gap, this review aims to explain the basic practical concepts of clinical MEG relevant to epilepsy with an emphasis on single equivalent dipole (sECD), which is one the most clinically validated and ubiquitously used source localization method, and illustrate and explain the regional topology and source dynamics relevant for clinical interpretation of MEG-EEG.
Collapse
Affiliation(s)
- Christopher Laohathai
- Division of Child Neurology, Department of Pediatrics, McGovern Medical School at UTHealth, Houston, TX, United States
- Department of Neurology, Saint Louis University, Saint Louis, MO, United States
| | - John S. Ebersole
- Northeast Regional Epilepsy Group, Atlantic Health Neuroscience Institute, Summit, NJ, United States
| | - John C. Mosher
- Department of Neurology, McGovern Medical School at UTHealth, Houston, TX, United States
| | - Anto I. Bagić
- University of Pittsburgh Comprehensive Epilepsy Center (UPCEC), Department of Neurology, University of Pittsburgh Medical Center, Pittsburg, PA, United States
| | - Ai Sumida
- Department of Neurology, McGovern Medical School at UTHealth, Houston, TX, United States
| | - Gretchen Von Allmen
- Division of Child Neurology, Department of Pediatrics, McGovern Medical School at UTHealth, Houston, TX, United States
| | - Michael E. Funke
- Division of Child Neurology, Department of Pediatrics, McGovern Medical School at UTHealth, Houston, TX, United States
| |
Collapse
|
12
|
Ricci L, Tamilia E, Alhilani M, Alter A, Scott Perry Μ, Madsen JR, Peters JM, Pearl PL, Papadelis C. Source imaging of seizure onset predicts surgical outcome in pediatric epilepsy. Clin Neurophysiol 2021; 132:1622-1635. [PMID: 34034087 PMCID: PMC8202024 DOI: 10.1016/j.clinph.2021.03.043] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Revised: 02/08/2021] [Accepted: 03/04/2021] [Indexed: 12/20/2022]
Abstract
Objective: To assess whether ictal electric source imaging (ESI) on low-density scalp EEG can approximate the seizure onset zone (SOZ) location and predict surgical outcome in children with refractory epilepsy undergoing surgery. Methods: We examined 35 children with refractory epilepsy. We dichotomized surgical outcome into seizure- and non-seizure-free. We identified ictal onsets recorded with scalp and intracranial EEG and localized them using equivalent current dipoles and standardized low-resolution magnetic tomography (sLORETA). We estimated the localization accuracy of scalp EEG as distance of scalp dipoles from intracranial dipoles. We also calculated the distances of scalp dipoles from resection, as well as their resection percentage and compared between seizure-free and non-seizure-free patients. We built receiver operating characteristic curves to test whether resection percentage predicted outcome. Results: Resection distance was lower in seizure-free patients for both dipoles (p = 0.006) and sLORETA (p = 0.04). Resection percentage predicted outcome with a sensitivity of 57.1% (95% CI, 34–78.2%), a specificity of 85.7% (95% CI, 57.2–98.2%) and an accuracy of 68.6% (95% CI, 50.7–83.5%) (p = 0.01). Conclusion: Ictal ESI performed on low-density scalp EEG can delineate the SOZ and predict outcome. Significance: Such an application may increase the number of children who are referred for epilepsy surgery and improve their outcome.
Collapse
Affiliation(s)
- Lorenzo Ricci
- Laboratory of Children's Brain Dynamics, Division of Newborn Medicine, Department of Medicine, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA; Unit of Neurology, Neurophysiology, Neurobiology, Department of Medicine, University Campus Bio-Medico of Rome, Rome, Italy
| | - Eleonora Tamilia
- Laboratory of Children's Brain Dynamics, Division of Newborn Medicine, Department of Medicine, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Michel Alhilani
- Laboratory of Children's Brain Dynamics, Division of Newborn Medicine, Department of Medicine, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA; The Hillingdon Hospital NHS Foundation Trust, London, UK
| | - Aliza Alter
- Division of Epilepsy and Clinical Neurophysiology, Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Μ Scott Perry
- Jane and John Justin Neurosciences Center, Cook Children's Health Care System, Fort Worth, TX, USA
| | - Joseph R Madsen
- Division of Epilepsy Surgery, Department of Neurosurgery, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Jurriaan M Peters
- Division of Epilepsy and Clinical Neurophysiology, Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Phillip L Pearl
- Division of Epilepsy and Clinical Neurophysiology, Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Christos Papadelis
- Laboratory of Children's Brain Dynamics, Division of Newborn Medicine, Department of Medicine, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA; Jane and John Justin Neurosciences Center, Cook Children's Health Care System, Fort Worth, TX, USA; School of Medicine, Texas Christian University and University of North Texas Health Science Center, Fort Worth, TX, USA; Department of Bioengineering, University of Texas at Arlington, Arlington, TX, USA.
| |
Collapse
|
13
|
Bagić AI, Funke ME, Kirsch HE, Tenney JR, Zillgitt AJ, Burgess RC. The 10 Common Evidence-Supported Indications for MEG in Epilepsy Surgery: An Illustrated Compendium. J Clin Neurophysiol 2021; 37:483-497. [PMID: 33165222 DOI: 10.1097/wnp.0000000000000726] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Unfamiliarity with the indications for and benefits of magnetoencephalography (MEG) persists, even in the epilepsy community, and hinders its acceptance to clinical practice, despite the evidence. The wide treatment gap for patients with drug-resistant epilepsy and immense underutilization of epilepsy surgery had similar effects. Thus, educating referring physicians (epileptologists, neurologists, and neurosurgeons) both about the value of epilepsy surgery and about the potential benefits of MEG can achieve synergy and greatly improve the process of selecting surgical candidates. As a practical step toward a comprehensive educational process to benefit potential MEG users, current MEG referrers, and newcomers to MEG, the authors have elected to provide an illustrated guide to 10 everyday situations where MEG can help in the evaluation of people with drug-resistant epilepsy. They are as follows: (1) lacking or imprecise hypothesis regarding a seizure onset; (2) negative MRI with a mesial temporal onset suspected; (3) multiple lesions on MRI; (4) large lesion on MRI; (5) diagnostic or therapeutic reoperation; (6) ambiguous EEG findings suggestive of "bilateral" or "generalized" pattern; (7) intrasylvian onset suspected; (8) interhemispheric onset suspected; (9) insular onset suspected; and (10) negative (i.e., spikeless) EEG. Only their practical implementation and furtherance of personal and collective education will lead to the potentially impactful synergy of the two-MEG and epilepsy surgery. Thus, while fulfilling our mission as physicians, we must not forget that ignoring the wealth of evidence about the vast underutilization of epilepsy surgery - and about the usefulness and value of MEG in selecting surgical candidates - is far from benign neglect.
Collapse
Affiliation(s)
- Anto I Bagić
- University of Pittsburgh Comprehensive Epilepsy Center (UPCEC), Department of Neurology, University of Pittsburgh Medical Center (UPMC), Pittsburgh, Pennsylvania, U.S.A
| | - Michael E Funke
- MEG Center, McGovern Medical School, UT Houston, Houston, Texas, U.S.A
| | - Heidi E Kirsch
- UCSF Biomagnetic Imaging Laboratory, UCSF, San Francisco, California, U.S.A
| | - Jeffrey R Tenney
- MEG Center, Cincinnati Children's Hospital Medical Center , Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, Ohio, U.S.A
| | - Andrew J Zillgitt
- Department of Neurology, Beaumont Health Adult Comprehensive Epilepsy Center, Neurosicence Center, Royal Oak, Michigan, U.S.A.; and
| | - Richard C Burgess
- Magnetoencephalography Laboratory, Cleveland Clinic Epilepsy Center, Cleveland, Ohio, U.S.A
| |
Collapse
|
14
|
Abstract
Noise sources in magnetoencephalography (MEG) include: (1) interference from outside the shielded room, (2) other people and devices inside the shielded room, (3) physiologic or nonphysiologic sources inside the patient, (4) activity from inside the head that is unrelated to the signal of interest, (5) intrinsic sensor and recording electronics noise, and (6) artifacts from other apparatus used during recording such as evoked response stimulators. There are other factors which corrupt MEG recording and interpretation and should also be considered "artifacts": (7) inadequate positioning of the patient, (8) changes in the head position during the recording, (9) incorrect co-registration, (10) spurious signals introduced during postprocessing, and (11) errors in fitting. The major means whereby magnetic interference can be reduced or eliminated are by recording inside a magnetically shielded room, using gradiometers that measure differential magnetic fields, real-time active compensation using reference sensors, and postprocessing with advanced spatio-temporal filters. Many of the artifacts that plague MEG are also seen in EEG, so an experienced electroencephalographer will have the advantage of being able to transfer his knowledge about artifacts to MEG. However, many of the procedures and software used during acquisition and analysis may themselves contribute artifact or distortion that must be recognized or prevented. In summary, MEG artifacts are not worse than EEG artifacts, but many are different, and-as with EEG-must be attended to.
Collapse
|
15
|
The Value of Source Localization for Clinical Magnetoencephalography: Beyond the Equivalent Current Dipole. J Clin Neurophysiol 2020; 37:537-544. [DOI: 10.1097/wnp.0000000000000487] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
16
|
Ye S, Yang L, Lu Y, Kucewicz MT, Brinkmann B, Nelson C, Sohrabpour A, Worrell GA, He B. Contribution of Ictal Source Imaging for Localizing Seizure Onset Zone in Patients With Focal Epilepsy. Neurology 2020; 96:e366-e375. [PMID: 33097598 DOI: 10.1212/wnl.0000000000011109] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Accepted: 09/01/2020] [Indexed: 11/15/2022] Open
Abstract
OBJECTIVE To determine whether seizure onset zone (SOZ) can be localized accurately prior to surgical planning in patients with focal epilepsy, we performed noninvasive EEG recordings and source localization analyses on 39 patients. METHODS In 39 patients with focal epilepsy, we recorded and extracted 138 seizures and 1,325 interictal epileptic discharges using high-density EEG. We investigated a novel approach for directly imaging sources of seizures and interictal spikes from high-density EEG recordings, and rigorously validated it for noninvasive localization of SOZ determined from intracranial EEG findings and surgical resection volume. Conventional source imaging analyses were also performed for comparison. RESULTS Ictal source imaging showed a concordance rate of 95% when compared to intracranial EEG or resection results. The average distance from estimation to seizure onset (intracranial) electrodes is 1.35 cm in patients with concordant results, and 0.74 cm to surgical resection boundary in patients with successful surgery. About 41% of the patients were found to have multiple types of interictal activities; coincidentally, a lower concordance rate and a significantly worse performance in localizing SOZ were observed in these patients. CONCLUSION Noninvasive ictal source imaging with high-density EEG recording can provide highly concordant results with clinical decisions obtained by invasive monitoring or confirmed by resective surgery. By means of direct seizure imaging using high-density scalp EEG recordings, the added value of ictal source imaging is particularly high in patients with complex interictal activity patterns, who may represent the most challenging cases with poor prognosis.
Collapse
Affiliation(s)
- Shuai Ye
- From the Department of Biomedical Engineering (S.Y., A.S., B.H.), Carnegie Mellon University, Pittsburgh, PA; Department of Biomedical Engineering (L.Y., Y.L.), University of Minnesota, Minneapolis; Mayo Clinic (M.T.K., B.B., C.N., G.A.W.), Rochester, MN
| | - Lin Yang
- From the Department of Biomedical Engineering (S.Y., A.S., B.H.), Carnegie Mellon University, Pittsburgh, PA; Department of Biomedical Engineering (L.Y., Y.L.), University of Minnesota, Minneapolis; Mayo Clinic (M.T.K., B.B., C.N., G.A.W.), Rochester, MN
| | - Yunfeng Lu
- From the Department of Biomedical Engineering (S.Y., A.S., B.H.), Carnegie Mellon University, Pittsburgh, PA; Department of Biomedical Engineering (L.Y., Y.L.), University of Minnesota, Minneapolis; Mayo Clinic (M.T.K., B.B., C.N., G.A.W.), Rochester, MN
| | - Michal T Kucewicz
- From the Department of Biomedical Engineering (S.Y., A.S., B.H.), Carnegie Mellon University, Pittsburgh, PA; Department of Biomedical Engineering (L.Y., Y.L.), University of Minnesota, Minneapolis; Mayo Clinic (M.T.K., B.B., C.N., G.A.W.), Rochester, MN
| | - Benjamin Brinkmann
- From the Department of Biomedical Engineering (S.Y., A.S., B.H.), Carnegie Mellon University, Pittsburgh, PA; Department of Biomedical Engineering (L.Y., Y.L.), University of Minnesota, Minneapolis; Mayo Clinic (M.T.K., B.B., C.N., G.A.W.), Rochester, MN
| | - Cindy Nelson
- From the Department of Biomedical Engineering (S.Y., A.S., B.H.), Carnegie Mellon University, Pittsburgh, PA; Department of Biomedical Engineering (L.Y., Y.L.), University of Minnesota, Minneapolis; Mayo Clinic (M.T.K., B.B., C.N., G.A.W.), Rochester, MN
| | - Abbas Sohrabpour
- From the Department of Biomedical Engineering (S.Y., A.S., B.H.), Carnegie Mellon University, Pittsburgh, PA; Department of Biomedical Engineering (L.Y., Y.L.), University of Minnesota, Minneapolis; Mayo Clinic (M.T.K., B.B., C.N., G.A.W.), Rochester, MN
| | - Gregory A Worrell
- From the Department of Biomedical Engineering (S.Y., A.S., B.H.), Carnegie Mellon University, Pittsburgh, PA; Department of Biomedical Engineering (L.Y., Y.L.), University of Minnesota, Minneapolis; Mayo Clinic (M.T.K., B.B., C.N., G.A.W.), Rochester, MN
| | - Bin He
- From the Department of Biomedical Engineering (S.Y., A.S., B.H.), Carnegie Mellon University, Pittsburgh, PA; Department of Biomedical Engineering (L.Y., Y.L.), University of Minnesota, Minneapolis; Mayo Clinic (M.T.K., B.B., C.N., G.A.W.), Rochester, MN.
| |
Collapse
|
17
|
Zheng L, Sheng J, Cen Z, Teng P, Wang J, Wang Q, Lee RR, Luan G, Huang M, Gao JH. Enhanced Fast-VESTAL for Magnetoencephalography Source Imaging: From Theory to Clinical Application in Epilepsy. IEEE Trans Biomed Eng 2020; 68:793-806. [PMID: 32790623 DOI: 10.1109/tbme.2020.3016468] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
A novel magnetoencephalography source imaging approach called Fast Vector-based Spatio-Temporal Analysis (Fast-VESTAL) has been successfully applied in creating source images from evoked and resting-state data from both healthy subjects and individuals with neurological and/or psychiatric disorders, but its reconstructed source images may show false-positive activations, especially under low signal-to-noise ratio conditions. Here, to effectively reduce false-positive artifacts, we introduced an enhanced Fast-VESTAL (eFast-VESTAL) approach that adopts generalized second-order cone programming. We compared the spatiotemporal characteristics of the eFast-VESTAL approach to those of the popular distributed source approaches (e.g., the minimum L2-norm/ mixed-norm methods) using computer simulations and auditory experiments. More importantly, we applied eFast-VESTAL to the presurgical evaluation of epilepsy. Our results demonstrated that eFast-VESTAL exhibited a lower dipole localization error and/or a higher correlation coefficient (CC) between the estimated source time series and ground truth under various conditions of source waveforms. Experimentally, eFast-VESTAL displayed more focal activation maps and a higher CC between the raw and predicted sensor data in response to auditory stimulation. Notably, eFast-VESTAL was the most accurate method for noninvasively detecting the epileptic zones determined using more invasive stereo-electroencephalography in the comparison.
Collapse
|
18
|
Pellegrino G, Xu M, Alkuwaiti A, Porras-Bettancourt M, Abbas G, Lina JM, Grova C, Kobayashi E. Effects of Independent Component Analysis on Magnetoencephalography Source Localization in Pre-surgical Frontal Lobe Epilepsy Patients. Front Neurol 2020; 11:479. [PMID: 32582009 PMCID: PMC7280485 DOI: 10.3389/fneur.2020.00479] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Accepted: 05/01/2020] [Indexed: 01/18/2023] Open
Abstract
Objective: Magnetoencephalography source imaging (MSI) of interictal epileptiform discharges (IED) is a useful presurgical tool in the evaluation of drug-resistant frontal lobe epilepsy (FLE) patients. Yet, failures in MSI can arise related to artifacts and to interference of background activity. Independent component analysis (ICA) is a popular denoising procedure but its clinical application remains challenging, as the selection of multiple independent components (IC) is controversial, operator dependent, and time consuming. We evaluated whether selecting only one IC of interest based on its similarity with the average IED field improves MSI in FLE. Methods: MSI was performed with the equivalent current dipole (ECD) technique and two distributed magnetic source imaging (dMSI) approaches: minimum norm estimate (MNE) and coherent Maximum Entropy on the Mean (cMEM). MSI accuracy was evaluated under three conditions: (1) ICA of continuous data (Cont_ICA), (2) ICA at the time of IED (IED_ICA), and (3) without ICA (No_ICA). Localization performance was quantitatively measured as actual distance of the source maximum in relation to the focus (Dmin), and spatial dispersion (SD) for dMSI. Results: After ICA, ECD Dmin did not change significantly (p > 0.200). For both dMSI techniques, ICA application worsened the source localization accuracy. We observed a worsening of both MNE Dmin (p < 0.05, consistently) and MNE SD (p < 0.001, consistently) for both ICA approaches. A similar behaviour was observed for cMEM, for which, however, Cont_ICA seemed less detrimental. Conclusion: We demonstrated that a simplified ICA approach selecting one IC of interest in combination with distributed magnetic source imaging can be detrimental. More complex approaches may provide better results but would be rather difficult to apply in real-world clinical setting. In a broader perspective, caution should be taken in applying ICA for source localization of interictal activity. To ensure optimal and useful results, effort should focus on acquiring good quality data, minimizing artifacts, and determining optimal candidacy for MEG, rather than counting on data cleaning techniques.
Collapse
Affiliation(s)
- Giovanni Pellegrino
- Neurology and Neurosurgery Department, Montreal Neurological Institute, McGill University, Montreal, QC, Canada
| | - Min Xu
- Neurology and Neurosurgery Department, Montreal Neurological Institute, McGill University, Montreal, QC, Canada.,Department of Geriatrics, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Abdulla Alkuwaiti
- Neurology and Neurosurgery Department, Montreal Neurological Institute, McGill University, Montreal, QC, Canada
| | - Manuel Porras-Bettancourt
- Neurology and Neurosurgery Department, Montreal Neurological Institute, McGill University, Montreal, QC, Canada
| | - Ghada Abbas
- Neurology and Neurosurgery Department, Montreal Neurological Institute, McGill University, Montreal, QC, Canada
| | - Jean-Marc Lina
- Multimodal Functional Imaging Laboratory, Biomedical Engineering Department, McGill University, Montreal, QC, Canada.,Département de Génie Électrique, École de Technologie Supérieure, Montreal, QC, Canada.,Centre de Recherches Mathematiques, Univeristé de Montréal, Montreal, QC, Canada
| | - Christophe Grova
- Neurology and Neurosurgery Department, Montreal Neurological Institute, McGill University, Montreal, QC, Canada.,Multimodal Functional Imaging Laboratory, Biomedical Engineering Department, McGill University, Montreal, QC, Canada.,Département de Génie Électrique, École de Technologie Supérieure, Montreal, QC, Canada.,Physics Department and PERFORM Centre, Concordia University, Montreal, QC, Canada
| | - Eliane Kobayashi
- Neurology and Neurosurgery Department, Montreal Neurological Institute, McGill University, Montreal, QC, Canada
| |
Collapse
|
19
|
Pellegrino G, Hedrich T, Porras-Bettancourt M, Lina JM, Aydin Ü, Hall J, Grova C, Kobayashi E. Accuracy and spatial properties of distributed magnetic source imaging techniques in the investigation of focal epilepsy patients. Hum Brain Mapp 2020; 41:3019-3033. [PMID: 32386115 PMCID: PMC7336148 DOI: 10.1002/hbm.24994] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Revised: 02/18/2020] [Accepted: 03/11/2020] [Indexed: 02/03/2023] Open
Abstract
Source localization of interictal epileptiform discharges (IEDs) is clinically useful in the presurgical workup of epilepsy patients. We aimed to compare the performance of four different distributed magnetic source imaging (dMSI) approaches: Minimum norm estimate (MNE), dynamic statistical parametric mapping (dSPM), standardized low-resolution electromagnetic tomography (sLORETA), and coherent maximum entropy on the mean (cMEM). We also evaluated whether a simple average of maps obtained from multiple inverse solutions (Ave) can improve localization accuracy. We analyzed dMSI of 206 IEDs derived from magnetoencephalography recordings in 28 focal epilepsy patients who had a well-defined focus determined through intracranial EEG (iEEG), epileptogenic MRI lesions or surgical resection. dMSI accuracy and spatial properties were quantitatively estimated as: (a) distance from the epilepsy focus, (b) reproducibility, (c) spatial dispersion (SD), (d) map extension, and (e) effect of thresholding on map properties. Clinical performance was excellent for all methods (median distance from the focus MNE = 2.4 mm; sLORETA = 3.5 mm; cMEM = 3.5 mm; dSPM = 6.8 mm, Ave = 0 mm). Ave showed the lowest distance between the map maximum and epilepsy focus (Dmin lower than cMEM, MNE, and dSPM, p = .021, p = .008, p < .001, respectively). cMEM showed the best spatial features, with lowest SD outside the focus (SD lower than all other methods, p < .001 consistently) and high contrast between the generator and surrounding regions. The average map Ave provided the best localization accuracy, whereas cMEM exhibited the lowest amount of spurious distant activity. dMSI techniques have the potential to significantly improve identification of iEEG targets and to guide surgical planning, especially when multiple methods are combined.
Collapse
Affiliation(s)
- Giovanni Pellegrino
- Department of Neurology and Neurosurgery, Montreal Neurological Institute, McGill University, Montreal, Quebec, Canada.,IRCCS Fondazione San Camillo Hospital, Venice, Italy.,Department of Multimodal Functional Imaging Lab, Biomedical Engineering, McGill University, Montreal, Quebec, Canada
| | - Tanguy Hedrich
- Department of Multimodal Functional Imaging Lab, Biomedical Engineering, McGill University, Montreal, Quebec, Canada
| | - Manuel Porras-Bettancourt
- Department of Neurology and Neurosurgery, Montreal Neurological Institute, McGill University, Montreal, Quebec, Canada
| | - Jean-Marc Lina
- Departement de Genie Electrique, Ecole de Technologie Superieure, Montreal, Quebec, Canada.,Centre de Recherches Mathematiques, Montréal, Quebec, Canada
| | - Ümit Aydin
- Physics Department and PERFORM Centre, Concordia University, Montreal, Quebec, Canada
| | - Jeffery Hall
- Department of Neurology and Neurosurgery, Montreal Neurological Institute, McGill University, Montreal, Quebec, Canada
| | - Christophe Grova
- Department of Neurology and Neurosurgery, Montreal Neurological Institute, McGill University, Montreal, Quebec, Canada.,Department of Multimodal Functional Imaging Lab, Biomedical Engineering, McGill University, Montreal, Quebec, Canada.,Centre de Recherches Mathematiques, Montréal, Quebec, Canada.,Physics Department and PERFORM Centre, Concordia University, Montreal, Quebec, Canada
| | - Eliane Kobayashi
- Department of Neurology and Neurosurgery, Montreal Neurological Institute, McGill University, Montreal, Quebec, Canada
| |
Collapse
|
20
|
Plummer C, Vogrin SJ, Woods WP, Murphy MA, Cook MJ, Liley DTJ. Interictal and ictal source localization for epilepsy surgery using high-density EEG with MEG: a prospective long-term study. Brain 2019; 142:932-951. [PMID: 30805596 PMCID: PMC6459284 DOI: 10.1093/brain/awz015] [Citation(s) in RCA: 81] [Impact Index Per Article: 16.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2018] [Revised: 10/07/2018] [Accepted: 12/05/2018] [Indexed: 11/17/2022] Open
Abstract
Drug-resistant focal epilepsy is a major clinical problem and surgery is under-used. Better non-invasive techniques for epileptogenic zone localization are needed when MRI shows no lesion or an extensive lesion. The problem is interictal and ictal localization before propagation from the epileptogenic zone. High-density EEG (HDEEG) and magnetoencephalography (MEG) offer millisecond-order temporal resolution to address this but co-acquisition is challenging, ictal MEG studies are rare, long-term prospective studies are lacking, and fundamental questions remain. Should HDEEG-MEG discharges be assessed independently [electroencephalographic source localization (ESL), magnetoencephalographic source localization (MSL)] or combined (EMSL) for source localization? Which phase of the discharge best characterizes the epileptogenic zone (defined by intracranial EEG and surgical resection relative to outcome)? Does this differ for interictal and ictal discharges? Does MEG detect mesial temporal lobe discharges? Thirteen patients (10 non-lesional, three extensive-lesional) underwent synchronized HDEEG-MEG (72–94 channel EEG, 306-sensor MEG). Source localization (standardized low-resolution tomographic analysis with MRI patient-individualized boundary-element method) was applied to averaged interictal epileptiform discharges (IED) and ictal discharges at three phases: ‘early-phase’ (first latency 90% explained variance), ‘mid-phase’ (first of 50% rising-phase, 50% mean global field power), ‘late-phase’ (negative peak). ‘Earliest-solution’ was the first of the three early-phase solutions (ESL, MSL, EMSL). Prospective follow-up was 3–21 (median 12) months before surgery, 14–39 (median 21) months after surgery. IEDs (n = 1474) were recorded, seen in: HDEEG only, 626 (42%); MEG only, 232 (16%); and both 616 (42%). Thirty-three seizures were captured, seen in: HDEEG only, seven (21%); MEG only, one (3%); and both 25 (76%). Intracranial EEG was done in nine patients. Engel scores were I (9/13, 69%), II (2/13,15%), and III (2/13). MEG detected baso-mesial temporal lobe epileptogenic zone sources. Epileptogenic zone OR [odds ratio(s)] were significantly higher for earliest-solution versus early-phase IED-surgical resection and earliest-solution versus all mid-phase and late-phase solutions. ESL outperformed EMSL for ictal-surgical resection [OR 3.54, 95% confidence interval (CI) 1.09–11.55, P = 0.036]. MSL outperformed EMSL for IED-intracranial EEG (OR 4.67, 95% CI 1.19–18.34, P = 0.027). ESL outperformed MSL for ictal-surgical resection (OR 3.73, 95% CI 1.16–12.03, P = 0.028) but was outperformed by MSL for IED-intracranial EEG (OR 0.18, 95% CI 0.05–0.73, P = 0.017). Thus, (i) HDEEG and MEG source solutions more accurately localize the epileptogenic zone at the earliest resolvable phase of interictal and ictal discharges, not mid-phase (as is common practice) or late peak-phase (when signal-to-noise ratios are maximal); (ii) from empirical observation of the differential timing of HDEEG and MEG discharges and based on the superiority of ESL plus MSL over either modality alone and over EMSL, concurrent HDEEG-MEG signals should be assessed independently, not combined; (iii) baso-mesial temporal lobe sources are detectable by MEG; and (iv) MEG is not ‘more accurate’ than HDEEG—emphasis is best placed on the earliest signal (whether HDEEG or MEG) amenable to source localization. Our findings challenge current practice and our reliance on invasive monitoring in these patients.
Collapse
Affiliation(s)
- Chris Plummer
- Department of Neurology, St Vincent's Hospital, Fitzroy, Australia.,School of Health Sciences, Swinburne University of Technology, Hawthorn, Australia.,Department of Medicine, University of Melbourne, Parkville, Australia
| | - Simon J Vogrin
- Department of Neurology, St Vincent's Hospital, Fitzroy, Australia.,School of Health Sciences, Swinburne University of Technology, Hawthorn, Australia.,Department of Medicine, University of Melbourne, Parkville, Australia
| | - William P Woods
- School of Health Sciences, Swinburne University of Technology, Hawthorn, Australia
| | - Michael A Murphy
- Department of Neurology, St Vincent's Hospital, Fitzroy, Australia.,Department of Medicine, University of Melbourne, Parkville, Australia
| | - Mark J Cook
- Department of Neurology, St Vincent's Hospital, Fitzroy, Australia.,Department of Medicine, University of Melbourne, Parkville, Australia.,Graeme Clark Institute of Biomedical Engineering, University of Melbourne, Parkville, Australia
| | - David T J Liley
- School of Health Sciences, Swinburne University of Technology, Hawthorn, Australia.,Department of Medicine, University of Melbourne, Parkville, Australia.,Centre for Human Psychopharmacology, Swinburne University of Technology, Hawthorn, Australia
| |
Collapse
|
21
|
Baumgartner C, Koren JP, Britto-Arias M, Zoche L, Pirker S. Presurgical epilepsy evaluation and epilepsy surgery. F1000Res 2019; 8. [PMID: 31700611 PMCID: PMC6820825 DOI: 10.12688/f1000research.17714.1] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 10/14/2019] [Indexed: 12/21/2022] Open
Abstract
With a prevalence of 0.8 to 1.2%, epilepsy represents one of the most frequent chronic neurological disorders; 30 to 40% of patients suffer from drug-resistant epilepsy (that is, seizures cannot be controlled adequately with antiepileptic drugs). Epilepsy surgery represents a valuable treatment option for 10 to 50% of these patients. Epilepsy surgery aims to control seizures by resection of the epileptogenic tissue while avoiding neuropsychological and other neurological deficits by sparing essential brain areas. The most common histopathological findings in epilepsy surgery specimens are hippocampal sclerosis in adults and focal cortical dysplasia in children. Whereas presurgical evaluations and surgeries in patients with mesial temporal sclerosis and benign tumors recently decreased in most centers, non-lesional patients, patients requiring intracranial recordings, and neocortical resections increased. Recent developments in neurophysiological techniques (high-density electroencephalography [EEG], magnetoencephalography, electrical and magnetic source imaging, EEG-functional magnetic resonance imaging [EEG-fMRI], and recording of pathological high-frequency oscillations), structural magnetic resonance imaging (MRI) (ultra-high-field imaging at 7 Tesla, novel imaging acquisition protocols, and advanced image analysis [post-processing] techniques), functional imaging (positron emission tomography and single-photon emission computed tomography co-registered to MRI), and fMRI significantly improved non-invasive presurgical evaluation and have opened the option of epilepsy surgery to patients previously not considered surgical candidates. Technical improvements of resective surgery techniques facilitate successful and safe operations in highly delicate brain areas like the perisylvian area in operculoinsular epilepsy. Novel less-invasive surgical techniques include stereotactic radiosurgery, MR-guided laser interstitial thermal therapy, and stereotactic intracerebral EEG-guided radiofrequency thermocoagulation.
Collapse
Affiliation(s)
- Christoph Baumgartner
- Department of Neurology, General Hospital Hietzing with Neurological Center Rosenhügel, Vienna, Austria.,Karl Landsteiner Institute for Clinical Epilepsy Research and Cognitive Neurology, Vienna, Austria.,Medical Faculty, Sigmund Freud University, Vienna, Austria
| | - Johannes P Koren
- Department of Neurology, General Hospital Hietzing with Neurological Center Rosenhügel, Vienna, Austria.,Karl Landsteiner Institute for Clinical Epilepsy Research and Cognitive Neurology, Vienna, Austria
| | - Martha Britto-Arias
- Department of Neurology, General Hospital Hietzing with Neurological Center Rosenhügel, Vienna, Austria.,Karl Landsteiner Institute for Clinical Epilepsy Research and Cognitive Neurology, Vienna, Austria
| | - Lea Zoche
- Department of Neurology, General Hospital Hietzing with Neurological Center Rosenhügel, Vienna, Austria.,Karl Landsteiner Institute for Clinical Epilepsy Research and Cognitive Neurology, Vienna, Austria
| | - Susanne Pirker
- Department of Neurology, General Hospital Hietzing with Neurological Center Rosenhügel, Vienna, Austria.,Karl Landsteiner Institute for Clinical Epilepsy Research and Cognitive Neurology, Vienna, Austria
| |
Collapse
|
22
|
Mouthaan BE, Rados M, Boon P, Carrette E, Diehl B, Jung J, Kimiskidis V, Kobulashvili T, Kuchukhidze G, Larsson PG, Leitinger M, Ryvlin P, Rugg-Gunn F, Seeck M, Vulliémoz S, Huiskamp G, Leijten FSS, Van Eijsden P, Trinka E, Braun KPJ. Diagnostic accuracy of interictal source imaging in presurgical epilepsy evaluation: A systematic review from the E-PILEPSY consortium. Clin Neurophysiol 2019; 130:845-855. [PMID: 30824202 DOI: 10.1016/j.clinph.2018.12.016] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2018] [Revised: 11/16/2018] [Accepted: 12/20/2018] [Indexed: 10/27/2022]
Abstract
OBJECTIVE Interictal high resolution (HR-) electric source imaging (ESI) and magnetic source imaging (MSI) are non-invasive tools to aid epileptogenic zone localization in epilepsy surgery candidates. We carried out a systematic review on the diagnostic accuracy and quality of evidence of these modalities. METHODS Embase, Pubmed and the Cochrane database were searched on 13 February 2017. Diagnostic accuracy studies taking post-surgical seizure outcome as reference standard were selected. Quality appraisal was based on the QUADAS-2 framework. RESULTS Eleven studies were included: eight MSI (n = 267), three HR-ESI (n = 127) studies. None was free from bias. This mostly involved: selection of operated patients only, interference of source imaging with surgical decision, and exclusion of indeterminate results. Summary sensitivity and specificity estimates were 82% (95% CI: 75-88%) and 53% (95% CI: 37-68%) for overall source imaging, with no statistical difference between MSI and HR-ESI. Specificity is higher when partially concordant results were included as non-concordant (p < 0.05). Inclusion of indeterminate test results as non-concordant lowered sensitivity (p < 0.05). CONCLUSIONS Source imaging has a relatively high sensitivity but low specificity for identification of the epileptogenic zone. SIGNIFICANCE We need higher quality studies allowing unbiased test evaluation to determine the added value and diagnostic accuracy of source imaging in the presurgical workup of refractory focal epilepsy.
Collapse
Affiliation(s)
- Brian E Mouthaan
- Department of (Child) Neurology and Neurosurgery, Brain Center Rudolf Magnus, University Medical Center Utrecht, PO Box 85090, 3508 AB Utrecht, The Netherlands
| | - Matea Rados
- Department of (Child) Neurology and Neurosurgery, Brain Center Rudolf Magnus, University Medical Center Utrecht, PO Box 85090, 3508 AB Utrecht, The Netherlands
| | - Paul Boon
- Reference Center for Refractory Epilepsy, Department of Neurology, Ghent University Hospital, Belgium
| | - Evelien Carrette
- Reference Center for Refractory Epilepsy, Department of Neurology, Ghent University Hospital, Belgium
| | - Beate Diehl
- National Hospital for Neurology and Neurosurgery, University College London Hospitals, London, United Kingdom; Department of Clinical and Experimental Epilepsy, University College, London, UK
| | - Julien Jung
- Department of Functional Neurology and Epileptology, Institute of Epilepsies (IDEE), Hospices Civils de Lyon, Lyon, France
| | - Vasilios Kimiskidis
- Laboratory of Clinical Neurophysiology, Medical School, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece
| | - Teia Kobulashvili
- Department of Neurology, Christian-Doppler University Hospital, Paracelsus Medical University, and Centre for Cognitive Neuroscience, Salzburg, Austria
| | - Giorgi Kuchukhidze
- Department of Neurology, Christian-Doppler University Hospital, Paracelsus Medical University, and Centre for Cognitive Neuroscience, Salzburg, Austria
| | - Pål G Larsson
- Department of Neurosurgery, Clinic of Surgery and Neuroscience, Oslo University Hospital, Norway
| | - Markus Leitinger
- Department of Neurology, Christian-Doppler University Hospital, Paracelsus Medical University, and Centre for Cognitive Neuroscience, Salzburg, Austria
| | - Philippe Ryvlin
- Department of Clinical Neurosciences, Lausanne University Hospital, Lausanne, Switzerland
| | - Fergus Rugg-Gunn
- National Hospital for Neurology and Neurosurgery, University College London Hospitals, London, United Kingdom; Department of Clinical and Experimental Epilepsy, University College, London, UK
| | - Margitta Seeck
- EEG and Epilepsy Unit, Department of Clinical Neurosciences, University Hospital of Geneva, Switzerland
| | - Serge Vulliémoz
- EEG and Epilepsy Unit, Department of Clinical Neurosciences, University Hospital of Geneva, Switzerland
| | - Geertjan Huiskamp
- Department of (Child) Neurology and Neurosurgery, Brain Center Rudolf Magnus, University Medical Center Utrecht, PO Box 85090, 3508 AB Utrecht, The Netherlands
| | - Frans S S Leijten
- Department of (Child) Neurology and Neurosurgery, Brain Center Rudolf Magnus, University Medical Center Utrecht, PO Box 85090, 3508 AB Utrecht, The Netherlands
| | - Pieter Van Eijsden
- Department of (Child) Neurology and Neurosurgery, Brain Center Rudolf Magnus, University Medical Center Utrecht, PO Box 85090, 3508 AB Utrecht, The Netherlands
| | - Eugen Trinka
- Department of Neurology, Christian-Doppler University Hospital, Paracelsus Medical University, and Centre for Cognitive Neuroscience, Salzburg, Austria; Institute of Public Health, Medical Decision Making and HTA, UMIT, Private University for Health Sciences, Medical Informatics and Technology, Hall in Tyrol, Austria
| | - Kees P J Braun
- Department of (Child) Neurology and Neurosurgery, Brain Center Rudolf Magnus, University Medical Center Utrecht, PO Box 85090, 3508 AB Utrecht, The Netherlands.
| | | |
Collapse
|
23
|
Magnetoencephalographic Mapping of Epileptic Spike Population Using Distributed Source Analysis: Comparison With Intracranial Electroencephalographic Spikes. J Clin Neurophysiol 2018; 35:339-345. [PMID: 29746391 DOI: 10.1097/wnp.0000000000000476] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
INTRODUCTION This study evaluates magnetoencephalographic (MEG) spike population as compared with intracranial electroencephalographic (IEEG) spikes using a quantitative method based on distributed source analysis. METHODS We retrospectively studied eight patients with medically intractable epilepsy who had an MEG and subsequent IEEG monitoring. Fifty MEG spikes were analyzed in each patient using minimum norm estimate. For individual spikes, each vertex in the source space was considered activated when its source amplitude at the peak latency was higher than a threshold, which was set at 50% of the maximum amplitude over all vertices. We mapped the total count of activation at each vertex. We also analyzed 50 IEEG spikes in the same manner over the intracranial electrodes and created the activation count map. The location of the electrodes was obtained in the MEG source space by coregistering postimplantation computed tomography to MRI. We estimated the MEG- and IEEG-active regions associated with the spike populations using the vertices/electrodes with a count over 25. RESULTS The activation count maps of MEG spikes demonstrated the localization associated with the spike population by variable count values at each vertex. The MEG-active region overlapped with 65 to 85% of the IEEG-active region in our patient group. CONCLUSIONS Mapping the MEG spike population is valid for demonstrating the trend of spikes clustering in patients with epilepsy. In addition, comparison of MEG and IEEG spikes quantitatively may be informative for understanding their relationship.
Collapse
|
24
|
The role of magnetoencephalography in the presurgical evaluation of patients with MRI-negative operculo-insular epilepsy. Seizure 2018; 61:104-110. [DOI: 10.1016/j.seizure.2018.07.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2018] [Revised: 06/30/2018] [Accepted: 07/08/2018] [Indexed: 10/28/2022] Open
|
25
|
Chowdhury RA, Pellegrino G, Aydin Ü, Lina JM, Dubeau F, Kobayashi E, Grova C. Reproducibility of EEG-MEG fusion source analysis of interictal spikes: Relevance in presurgical evaluation of epilepsy. Hum Brain Mapp 2017; 39:880-901. [PMID: 29164737 DOI: 10.1002/hbm.23889] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Revised: 11/03/2017] [Accepted: 11/07/2017] [Indexed: 11/06/2022] Open
Abstract
Fusion of electroencephalography (EEG) and magnetoencephalography (MEG) data using maximum entropy on the mean method (MEM-fusion) takes advantage of the complementarities between EEG and MEG to improve localization accuracy. Simulation studies demonstrated MEM-fusion to be robust especially in noisy conditions such as single spike source localizations (SSSL). Our objective was to assess the reliability of SSSL using MEM-fusion on clinical data. We proposed to cluster SSSL results to find the most reliable and consistent source map from the reconstructed sources, the so-called consensus map. Thirty-four types of interictal epileptic discharges (IEDs) were analyzed from 26 patients with well-defined epileptogenic focus. SSSLs were performed on EEG, MEG, and fusion data and consensus maps were estimated using hierarchical clustering. Qualitative (spike-to-spike reproducibility rate, SSR) and quantitative (localization error and spatial dispersion) assessments were performed using the epileptogenic focus as clinical reference. Fusion SSSL provided significantly better results than EEG or MEG alone. Fusion found at least one cluster concordant with the clinical reference in all cases. This concordant cluster was always the one involving the highest number of spikes. Fusion yielded highest reproducibility (SSR EEG = 55%, MEG = 71%, fusion = 90%) and lowest localization error. Also, using only few channels from either modality (21EEG + 272MEG or 54EEG + 25MEG) was sufficient to reach accurate fusion. MEM-fusion with consensus map approach provides an objective way of finding the most reliable and concordant generators of IEDs. We, therefore, suggest the pertinence of SSSL using MEM-fusion as a valuable clinical tool for presurgical evaluation of epilepsy.
Collapse
Affiliation(s)
- Rasheda Arman Chowdhury
- Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Montreal, Québec, Canada
| | | | - Ümit Aydin
- Multimodal Functional Imaging Lab, Department of Physics and PERFORM Centre, Concordia University, Montreal, Québec, Canada
| | - Jean-Marc Lina
- Ecole de Technologie Supérieure, Montréal, Québec, Canada.,Centre de Recherches Mathématiques, Université de Montréal, Montréal, Québec, Canada
| | - François Dubeau
- Neurology and Neurosurgery Department, Montreal Neurological Institute, McGill University, Montreal, Québec, Canada
| | - Eliane Kobayashi
- Neurology and Neurosurgery Department, Montreal Neurological Institute, McGill University, Montreal, Québec, Canada
| | - Christophe Grova
- Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Montreal, Québec, Canada.,Centre de Recherches Mathématiques, Université de Montréal, Montréal, Québec, Canada.,Neurology and Neurosurgery Department, Montreal Neurological Institute, McGill University, Montreal, Québec, Canada.,Multimodal Functional Imaging Lab, Department of Physics and PERFORM Centre, Concordia University, Montreal, Québec, Canada
| |
Collapse
|
26
|
Rossi Sebastiano D, Visani E, Duran D, Freri E, Panzica F, Chiapparini L, Ragona F, Granata T, Franceschetti S. Epileptic spikes in Rasmussen's encephalitis: Migratory pattern and short-term evolution. A MEG study. Clin Neurophysiol 2017; 128:1898-1905. [PMID: 28826020 DOI: 10.1016/j.clinph.2017.07.401] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2017] [Revised: 07/12/2017] [Accepted: 07/15/2017] [Indexed: 11/25/2022]
Abstract
OBJECTIVE We aimed this study at identifying cortical areas involved in the generation of interictal spikes in Rasmussen's Encephalitis (RE) patients using magnetoencephalography (MEG), at comparing spike localization with the degree of cortical atrophy detected by MRI, and at identifying short-term changes during the follow-up. METHODS Five patients with RE underwent two MEG and magnetic resonance imaging (MRI) (six months interval). The sources of visually detected spikes were estimated using equivalent current dipoles technique; these were then superimposed on individual MRI and clustered; the locations of the clusters were related to the MRI stage of cortical atrophy. RESULTS All patients showed spikes and clusters located in different cortical areas in both recordings; the locations had a limited correspondence with cortical atrophy. The second recordings showed changes in the localisation of spikes and clusters, and confirmed the dissimilarities with neuroradiological abnormalities. CONCLUSIONS The presence of clusters of spikes of variable localisation suggests that RE progresses in a multifocal and fluctuating manner. The cortical areas most involved in epileptogenesis did not completely coincide with the most atrophic areas. SIGNIFICANCE MEG can contribute to evaluating multifocal hemispheric spikes in RE and to better understand the time course of epileptogenic process.
Collapse
Affiliation(s)
| | - Elisa Visani
- Neurophysiopathology Department and Epilepsy Centre, IRCCS Foundation, Milan, Italy
| | - Dunja Duran
- Neurophysiopathology Department and Epilepsy Centre, IRCCS Foundation, Milan, Italy
| | - Elena Freri
- Department of Pediatric Neuroscience, Carlo Besta Neurological Institute, IRCCS Foundation, Milan, Italy
| | - Ferruccio Panzica
- Neurophysiopathology Department and Epilepsy Centre, IRCCS Foundation, Milan, Italy
| | - Luisa Chiapparini
- Neuroradiology Department, Carlo Besta Neurological Institute, IRCCS Foundation, Milan, Italy
| | - Francesca Ragona
- Department of Pediatric Neuroscience, Carlo Besta Neurological Institute, IRCCS Foundation, Milan, Italy
| | - Tiziana Granata
- Department of Pediatric Neuroscience, Carlo Besta Neurological Institute, IRCCS Foundation, Milan, Italy
| | | |
Collapse
|
27
|
Abdallah C, Maillard LG, Rikir E, Jonas J, Thiriaux A, Gavaret M, Bartolomei F, Colnat-Coulbois S, Vignal JP, Koessler L. Localizing value of electrical source imaging: Frontal lobe, malformations of cortical development and negative MRI related epilepsies are the best candidates. NEUROIMAGE-CLINICAL 2017; 16:319-329. [PMID: 28856095 PMCID: PMC5565782 DOI: 10.1016/j.nicl.2017.08.009] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2016] [Revised: 07/24/2017] [Accepted: 08/07/2017] [Indexed: 11/29/2022]
Abstract
OBJECTIVE We aimed to prospectively assess the anatomical concordance of electric source localizations of interictal discharges with the epileptogenic zone (EZ) estimated by stereo-electroencephalography (SEEG) according to different subgroups: the type of epilepsy, the presence of a structural MRI lesion, the aetiology and the depth of the EZ. METHODS In a prospective multicentric observational study, we enrolled 85 consecutive patients undergoing pre-surgical SEEG investigation for focal drug-resistant epilepsy. Electric source imaging (ESI) was performed before SEEG. Source localizations were obtained from dipolar and distributed source methods. Anatomical concordance between ESI and EZ was defined according to 36 predefined sublobar regions. ESI was interpreted blinded to- and subsequently compared with SEEG estimated EZ. RESULTS 74 patients were finally analyzed. 38 patients had temporal and 36 extra-temporal lobe epilepsy. MRI was positive in 52. 41 patients had malformation of cortical development (MCD), 33 had another or an unknown aetiology. EZ was medial in 27, lateral in 13, and medio-lateral in 34. In the overall cohort, ESI completely or partly localized the EZ in 85%: full concordance in 13 cases and partial concordance in 50 cases. The rate of ESI full concordance with EZ was significantly higher in (i) frontal lobe epilepsy (46%; p = 0.05), (ii) cases of negative MRI (36%; p = 0.01) and (iii) MCD (27%; p = 0.03). The rate of ESI full concordance with EZ was not statistically different according to the depth of the EZ. SIGNIFICANCE We prospectively demonstrated that ESI more accurately estimated the EZ in subgroups of patients who are often the most difficult cases in epilepsy surgery: frontal lobe epilepsy, negative MRI and the presence of MCD.
Collapse
Affiliation(s)
- Chifaou Abdallah
- Neurology Department, University Hospital of Nancy, Nancy, France
| | - Louis G Maillard
- Neurology Department, University Hospital of Nancy, Nancy, France.,CRAN, UMR 7039, Lorraine University, Vandœuvre-les-Nancy Cedex, France.,CNRS, CRAN, UMR 7039, Vandœuvre-les-Nancy Cedex, France.,Medical Faculty, Lorraine University, Nancy, France
| | - Estelle Rikir
- Neurology Department, University Hospital of Sart-Tilman, Liege, Belgium.,Medical Faculty, Liege University, Liege, Belgium
| | - Jacques Jonas
- Neurology Department, University Hospital of Nancy, Nancy, France.,CRAN, UMR 7039, Lorraine University, Vandœuvre-les-Nancy Cedex, France.,CNRS, CRAN, UMR 7039, Vandœuvre-les-Nancy Cedex, France
| | - Anne Thiriaux
- Neurology department, University Hospital of Reims, Reims, France
| | - Martine Gavaret
- Clinical Neurophysiology Department, AP-HM, University Hospital la Timone, Marseille, France.,INSERM UMR 1106, Institut de Neurosciences des Systemes, Marseille, France.,Medical Faculty, Aix-Marseille University, Marseille, France
| | - Fabrice Bartolomei
- Clinical Neurophysiology Department, AP-HM, University Hospital la Timone, Marseille, France.,INSERM UMR 1106, Institut de Neurosciences des Systemes, Marseille, France.,Medical Faculty, Aix-Marseille University, Marseille, France
| | - Sophie Colnat-Coulbois
- Medical Faculty, Lorraine University, Nancy, France.,Neurosurgery Department, University Hospital of Nancy, Nancy, France
| | - Jean-Pierre Vignal
- Neurology Department, University Hospital of Nancy, Nancy, France.,CRAN, UMR 7039, Lorraine University, Vandœuvre-les-Nancy Cedex, France.,CNRS, CRAN, UMR 7039, Vandœuvre-les-Nancy Cedex, France
| | - Laurent Koessler
- Neurology Department, University Hospital of Nancy, Nancy, France.,CRAN, UMR 7039, Lorraine University, Vandœuvre-les-Nancy Cedex, France.,CNRS, CRAN, UMR 7039, Vandœuvre-les-Nancy Cedex, France
| |
Collapse
|
28
|
Wang Q, Teng P, Luan G. Magnetoencephalography in Preoperative Epileptic Foci Localization: Enlightenment from Cognitive Studies. Front Comput Neurosci 2017; 11:58. [PMID: 28701945 PMCID: PMC5487414 DOI: 10.3389/fncom.2017.00058] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Accepted: 06/12/2017] [Indexed: 02/02/2023] Open
Abstract
Over 30% epileptic patients are refractory to medication, who are amenable to neurosurgical treatment. Non-invasive brain imaging technologies including video-electroencephalogram (EEG), magnetic resonance imaging (MRI), and magnetoencephalography (MEG) are widely used in presurgical assessment of epileptic patients. This review mainly discussed the current development of clinical MEG imaging as a diagnose approach, and its correlations with the golden standard intracranial electroencephalogram (iEEG). More importantly, this review discussed the possible applications of functional networks in preoperative epileptic foci localization in future studies.
Collapse
Affiliation(s)
- Qian Wang
- Beijing Key Laboratory of Epilepsy, Sanbo Brain Hospital, Capital Medical UniversityBeijing, China.,Department of Neurosurgery, Epilepsy Center, Sanbo Brain Hospital, Capital Medical UniversityBeijing, China
| | - Pengfei Teng
- Department of Neurosurgery, Epilepsy Center, Sanbo Brain Hospital, Capital Medical UniversityBeijing, China
| | - Guoming Luan
- Beijing Key Laboratory of Epilepsy, Sanbo Brain Hospital, Capital Medical UniversityBeijing, China.,Department of Neurosurgery, Epilepsy Center, Sanbo Brain Hospital, Capital Medical UniversityBeijing, China.,Beijing Institute for Brain Disorders, Capital Medical UniversityBeijing, China
| |
Collapse
|
29
|
The relationship between morphological lesion, magnetic source imaging, and intracranial stereo-electroencephalography in focal cortical dysplasia. NEUROIMAGE-CLINICAL 2017; 15:71-79. [PMID: 28491494 PMCID: PMC5412109 DOI: 10.1016/j.nicl.2017.04.018] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/05/2017] [Revised: 04/14/2017] [Accepted: 04/18/2017] [Indexed: 02/08/2023]
Abstract
Magnetoencephalography (MEG) is a useful non-invasive technique for presurgical evaluation of focal cortical dysplasia patients. We aimed at clarifying the precise spatial relationship between the spiking volume determined with MEG, the seizure onset zone and the lesional volume in patients with focal cortical dysplasia. We studied the spatial relationships between the MEG spiking volume determined with a recent analysis pipeline, the seizure-onset zone location determined with a quantitative index calculated from intracranial EEG signals (‘Epileptogenicity Index’) and the lesional volume delineated on brain MRI in 11 patients with Focal Cortical Dysplasia explored with Stereo-electroencephalography (SEEG). A significant correlation between the MEG spiking activity and the Epileptogenicity Index was found in 8/11 patients. 7/8 patients were operated upon and had good surgical outcome. For three patients, no correlation between Epileptogenicity Index and spiking activity was observed; only one of those three patients had good surgical outcome. The lesion was at least partially overlapping with the seizure-onset zone in 8/9 patients with a lesion clearly identifiable by MRI. However, 57% of the SEEG epileptogenic contacts were located outside of the lesional volume. Lastly 44% of the highly epileptogenic SEEG contacts were located within the spiking volume and 22% of them were located exclusively in the spiking volume and not in the lesion. For 7/9 patients with a lesion, < 50% of epileptogenic SEEG contacts were included within the lesion: for 5/7 patients MEG provided an added value for targeting the epileptogenic region through intracranial electrodes, while for two of seven patients MEG detected only a few extralesional epileptogenic contacts. Our study suggests that modeling of the spiking volume with MEG is a promising tool to localize non-invasively the seizure-onset zone in patients with focal cortical dysplasia. Combined with brain MRI, MEG modeling of the spiking volume contributes to delineate the spatial extent of the seizure-onset zone. This study investigates the relationship between the seizure focus, the lesion and the MEG spikes in Focal Cortical Dysplasia (FCD). The lesion, the seizure-onset zone and the MEG spiking volumes in FCD patients are largely co-extensive brain regions. MEG is helpful to disclose epileptogenic areas remote from the lesion. MEG is complementary to MRI to estimate the full extent of the SOZ in patients with FCD.
Collapse
|
30
|
Ducis K, Guan J, Karsy M, Bollo RJ. Preoperative evaluation and surgical decision-making in pediatric epilepsy surgery. Transl Pediatr 2016; 5:169-179. [PMID: 27709099 PMCID: PMC5035764 DOI: 10.21037/tp.2016.06.02] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
Epilepsy is a common disease in the pediatric population, and the majority of cases are controlled with medications and lifestyle modification. For the children whose seizures are pharmacoresistant, continued epileptic activity can have a severely detrimental impact on cognitive development. Early referral of children with drug-resistant seizures to a pediatric epilepsy surgery center for evaluation is critical to achieving optimal patient outcomes. There are several components to a thorough presurgical evaluation, including a detailed medical history and physical examination, noninvasive testing including electroencephalogram, magnetic resonance imaging (MRI) of the brain, and often metabolic imaging. When necessary, invasive diagnostic testing using intracranial monitoring can be used. The identification of an epileptic focus may allow resection or disconnection from normal brain structures, with the ultimate goal of complete seizure remission. Additional operative measures can decrease seizure frequency and/or intensity if a clear epileptic focus cannot be identified. In this review, we will discuss the nuances of presurgical evaluation and decision-making in the management of children with drug-resistant epilepsy (DRE).
Collapse
Affiliation(s)
- Katrina Ducis
- Department of Neurosurgery, University of Vermont School of Medicine, Burlington, VT, USA; ; Department of Neurosurgery, University of Utah School of Medicine, Salt Lake City, UT, USA
| | - Jian Guan
- Department of Neurosurgery, University of Utah School of Medicine, Salt Lake City, UT, USA
| | - Michael Karsy
- Department of Neurosurgery, University of Utah School of Medicine, Salt Lake City, UT, USA
| | - Robert J Bollo
- Department of Neurosurgery, University of Utah School of Medicine, Salt Lake City, UT, USA; ; Division of Pediatric Neurosurgery, Primary Children's Hospital, Salt Lake City, UT, USA
| |
Collapse
|
31
|
Nakajima M, Widjaja E, Baba S, Sato Y, Yoshida R, Tabei M, Okazaki A, Sakuma S, Holowka SA, Ochi A, Snead OC, Rutka JT, Drake JM, Shiraishi H, Doesburg S, Otsubo H. Remote MEG dipoles in focal cortical dysplasia at bottom of sulcus. Epilepsia 2016; 57:1169-78. [DOI: 10.1111/epi.13399] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/04/2016] [Indexed: 12/20/2022]
Affiliation(s)
- Midori Nakajima
- Division of Neurology; The Hospital for Sick Children; Toronto Ontario Canada
- Department of Pediatrics; Graduate School of Medicine; Hokkaido University; Sapporo Japan
| | - Elysa Widjaja
- Diagnostic Imaging; The Hospital for Sick Children; Toronto Ontario Canada
| | - Shiro Baba
- Division of Neurology; The Hospital for Sick Children; Toronto Ontario Canada
| | - Yosuke Sato
- Division of Neurology; The Hospital for Sick Children; Toronto Ontario Canada
| | - Ryuhei Yoshida
- Division of Neurology; The Hospital for Sick Children; Toronto Ontario Canada
| | - Maya Tabei
- Division of Neurology; The Hospital for Sick Children; Toronto Ontario Canada
| | - Ayaka Okazaki
- Division of Neurology; The Hospital for Sick Children; Toronto Ontario Canada
| | - Satoru Sakuma
- Division of Neurology; The Hospital for Sick Children; Toronto Ontario Canada
| | | | - Ayako Ochi
- Division of Neurology; The Hospital for Sick Children; Toronto Ontario Canada
| | - O. Carter Snead
- Division of Neurology; The Hospital for Sick Children; Toronto Ontario Canada
| | - James T. Rutka
- Division of Neurosurgery; The Hospital for Sick Children; Toronto Ontario Canada
| | - James M. Drake
- Division of Neurosurgery; The Hospital for Sick Children; Toronto Ontario Canada
| | - Hideaki Shiraishi
- Department of Pediatrics; Graduate School of Medicine; Hokkaido University; Sapporo Japan
| | - Sam Doesburg
- Department of Biomedical Physiology and Kinesiology; Simon Fraser University; Burnaby British Columbia Canada
| | - Hiroshi Otsubo
- Division of Neurology; The Hospital for Sick Children; Toronto Ontario Canada
| |
Collapse
|
32
|
Ahmed R, Rutka JT. The role of MEG in pre-surgical evaluation of epilepsy: current use and future directions. Expert Rev Neurother 2016; 16:795-801. [DOI: 10.1080/14737175.2016.1181544] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Raheel Ahmed
- Division of Neurosurgery, The Hospital for Sick Children, Toronto, Canada
| | - James T. Rutka
- Division of Neurosurgery, The Hospital for Sick Children, Toronto, Canada
| |
Collapse
|
33
|
Pellegrino G, Hedrich T, Chowdhury R, Hall JA, Lina JM, Dubeau F, Kobayashi E, Grova C. Source localization of the seizure onset zone from ictal EEG/MEG data. Hum Brain Mapp 2016; 37:2528-46. [PMID: 27059157 DOI: 10.1002/hbm.23191] [Citation(s) in RCA: 70] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2015] [Revised: 03/07/2016] [Accepted: 03/10/2016] [Indexed: 11/08/2022] Open
Abstract
INTRODUCTION Surgical treatment of drug-resistant epilepsy relies on the identification of the seizure onset zone (SOZ) and often requires intracranial EEG (iEEG). We have developed a new approach for non-invasive magnetic and electric source imaging of the SOZ (MSI-SOZ and ESI-SOZ) from ictal magnetoencephalography (MEG) and EEG recordings, using wavelet-based Maximum Entropy on the Mean (wMEM) method. We compared the performance of MSI-SOZ and ESI-SOZ with interictal spike source localization (MSI-spikes and ESI-spikes) and clinical localization of the SOZ (i.e., based on iEEG or lesion topography, denoted as clinical-SOZ). METHODS A total of 46 MEG or EEG seizures from 13 patients were analyzed. wMEM was applied around seizure onset, centered on the frequency band showing the strongest power change. Principal component analysis applied to spatiotemporal reconstructed wMEM sources (0.4-1 s around seizure onset) identified the main spatial pattern of ictal oscillations. Qualitative sublobar concordance and quantitative measures of distance and spatial overlaps were estimated to compare MSI/ESI-SOZ with MSI/ESI-Spikes and clinical-SOZ. RESULTS MSI/ESI-SOZ were concordant with clinical-SOZ in 81% of seizures (MSI 90%, ESI 64%). MSI-SOZ was more accurate and identified sources closer to the clinical-SOZ (P = 0.012) and to MSI-Spikes (P = 0.040) as compared with ESI-SOZ. MSI/ESI-SOZ and MSI/ESI-Spikes did not differ in terms of concordance and distance from the clinical-SOZ. CONCLUSIONS wMEM allows non-invasive localization of the SOZ from ictal MEG and EEG. MSI-SOZ performs better than ESI-SOZ. MSI/ESI-SOZ can provide important additional information to MSI/ESI-Spikes during presurgical evaluation. Hum Brain Mapp 37:2528-2546, 2016. © 2016 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Giovanni Pellegrino
- Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Montreal, Québec, Canada.,Neurology and Neurosurgery Department, Montreal Neurological Institute, McGill University, Montreal, Québec, Canada
| | - Tanguy Hedrich
- Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Montreal, Québec, Canada
| | - Rasheda Chowdhury
- Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Montreal, Québec, Canada
| | - Jeffery A Hall
- Neurology and Neurosurgery Department, Montreal Neurological Institute, McGill University, Montreal, Québec, Canada
| | - Jean-Marc Lina
- Département de Génie Electrique, École de Technologie Supérieure, Montreal, Québec, Canada.,Centre De Recherches En Mathématiques, Montreal, Québec, Canada.,Centre D'etudes Avancées En Médecine Du Sommeil, Centre De Recherche De L'hôpital Sacré-Coeur De Montréal, Montreal, Québec, Canada
| | - Francois Dubeau
- Neurology and Neurosurgery Department, Montreal Neurological Institute, McGill University, Montreal, Québec, Canada
| | - Eliane Kobayashi
- Neurology and Neurosurgery Department, Montreal Neurological Institute, McGill University, Montreal, Québec, Canada
| | - Christophe Grova
- Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Montreal, Québec, Canada.,Neurology and Neurosurgery Department, Montreal Neurological Institute, McGill University, Montreal, Québec, Canada.,Centre De Recherches En Mathématiques, Montreal, Québec, Canada.,Physics Department and PERFORM Centre, Concordia University, Montreal, Québec, Canada
| |
Collapse
|
34
|
Grova C, Aiguabella M, Zelmann R, Lina JM, Hall JA, Kobayashi E. Intracranial EEG potentials estimated from MEG sources: A new approach to correlate MEG and iEEG data in epilepsy. Hum Brain Mapp 2016; 37:1661-83. [PMID: 26931511 DOI: 10.1002/hbm.23127] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2015] [Revised: 12/18/2015] [Accepted: 01/17/2016] [Indexed: 01/19/2023] Open
Abstract
Detection of epileptic spikes in MagnetoEncephaloGraphy (MEG) requires synchronized neuronal activity over a minimum of 4cm2. We previously validated the Maximum Entropy on the Mean (MEM) as a source localization able to recover the spatial extent of the epileptic spike generators. The purpose of this study was to evaluate quantitatively, using intracranial EEG (iEEG), the spatial extent recovered from MEG sources by estimating iEEG potentials generated by these MEG sources. We evaluated five patients with focal epilepsy who had a pre-operative MEG acquisition and iEEG with MRI-compatible electrodes. Individual MEG epileptic spikes were localized along the cortical surface segmented from a pre-operative MRI, which was co-registered with the MRI obtained with iEEG electrodes in place for identification of iEEG contacts. An iEEG forward model estimated the influence of every dipolar source of the cortical surface on each iEEG contact. This iEEG forward model was applied to MEG sources to estimate iEEG potentials that would have been generated by these sources. MEG-estimated iEEG potentials were compared with measured iEEG potentials using four source localization methods: two variants of MEM and two standard methods equivalent to minimum norm and LORETA estimates. Our results demonstrated an excellent MEG/iEEG correspondence in the presumed focus for four out of five patients. In one patient, the deep generator identified in iEEG could not be localized in MEG. MEG-estimated iEEG potentials is a promising method to evaluate which MEG sources could be retrieved and validated with iEEG data, providing accurate results especially when applied to MEM localizations. Hum Brain Mapp 37:1661-1683, 2016. © 2016 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Christophe Grova
- Montreal Neurological Institute, Department of Neurology and Neurosurgery, McGill University, Montreal, Québec, Canada.,Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Montreal, Québec, Canada.,Physics Department and PERFORM Centre, Concordia University, Montreal, Québec, Canada.,Centre De Recherches En Mathématiques, Montreal, Québec, Canada
| | - Maria Aiguabella
- Montreal Neurological Institute, Department of Neurology and Neurosurgery, McGill University, Montreal, Québec, Canada
| | - Rina Zelmann
- Montreal Neurological Institute, Department of Neurology and Neurosurgery, McGill University, Montreal, Québec, Canada
| | - Jean-Marc Lina
- Centre De Recherches En Mathématiques, Montreal, Québec, Canada.,Electrical Engineering Department, Ecole De Technologie Supérieure, Montreal, Québec, Canada.,Centre D'etudes Avancées En Médecine Du Sommeil, Centre De Recherche De L'hôpital Sacré-Coeur De Montréal, Montreal, Québec, Canada
| | - Jeffery A Hall
- Montreal Neurological Institute, Department of Neurology and Neurosurgery, McGill University, Montreal, Québec, Canada
| | - Eliane Kobayashi
- Montreal Neurological Institute, Department of Neurology and Neurosurgery, McGill University, Montreal, Québec, Canada
| |
Collapse
|
35
|
Hamandi K, Routley BC, Koelewijn L, Singh KD. Non-invasive brain mapping in epilepsy: Applications from magnetoencephalography. J Neurosci Methods 2015; 260:283-91. [PMID: 26642968 DOI: 10.1016/j.jneumeth.2015.11.012] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2015] [Revised: 11/17/2015] [Accepted: 11/18/2015] [Indexed: 01/11/2023]
Abstract
BACKGROUND Non-invasive in vivo neurophysiological recordings with EEG/MEG are key to the diagnosis, classification, and further understanding of epilepsy. Historically the emphasis of these recordings has been the localisation of the putative sources of epileptic discharges. More recent developments see new techniques studying oscillatory dynamics, connectivity and network properties. NEW METHOD New analysis strategies for whole head MEG include the development of spatial filters or beamformers for source localisation, time-frequency analysis for cortical dynamics and graph theory applications for connectivity. RESULTS The idea of epilepsy as a network disorder is not new, and new applications of structural and functional brain imaging show differences in cortical and subcortical networks in patients with epilepsy compared to controls. Concepts of 'focal' and 'generalised' are challenged by evidence of focal onsets in generalised epileptic discharges, and widespread network changes in focal epilepsy. Spectral analyses can show differences in induced cortical response profiles, particularly in photosensitive epilepsy. COMPARISON WITH EXISTING METHOD This review focuses on the application of MEG in the study of epilepsy, starting with a brief historical perspective, followed by novel applications of source localisation, time-frequency and connectivity analyses. CONCLUSION Novel MEG analyses approaches show altered cortical dynamics and widespread network alterations in focal and generalised epilepsies, and identification of regional network abnormalities may have a role in epilepsy surgery evaluation.
Collapse
Affiliation(s)
- Khalid Hamandi
- The Alan Richens Welsh Epilepsy Centre, University Hospital of Wales, Cardiff CF5 6LR, United Kingdom.
| | - Bethany C Routley
- Cardiff University Brain Research Imaging Centre, School of Psychology, Cardiff University, Cardiff CF10 3AT, United Kingdom
| | - Loes Koelewijn
- Cardiff University Brain Research Imaging Centre, School of Psychology, Cardiff University, Cardiff CF10 3AT, United Kingdom
| | - Krish D Singh
- Cardiff University Brain Research Imaging Centre, School of Psychology, Cardiff University, Cardiff CF10 3AT, United Kingdom
| |
Collapse
|
36
|
Zhu H, Zhu J, Bao FS, Liu H, Zhu X, Wu T, Yang L, Zou Y, Zhang R, Zheng G. Statistical parametric mapping for analyzing interictal magnetoencephalography in patients with left frontal lobe epilepsy. Seizure 2015; 34:38-43. [PMID: 26707266 DOI: 10.1016/j.seizure.2015.11.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2015] [Revised: 11/11/2015] [Accepted: 11/13/2015] [Indexed: 10/22/2022] Open
Abstract
PURPOSE Frontal lobe epilepsy is a common epileptic disorder and is characterized by recurring seizures that arise in the frontal lobes. The purpose of this study is to identify the epileptogenic regions and other abnormal regions in patients with left frontal lobe epilepsy (LFLE) based on the magnetoencephalogram (MEG), and to understand the effects of clinical variables on brain activities in patients with LFLE. METHOD Fifteen patients with LFLE (23.20 ± 8.68 years, 6 female and 9 male) and 16 healthy controls (23.13 ± 7.66 years, 6 female and 10 male) were included in resting-stage MEG examinations. Epileptogenic regions of LFLE patients were confirmed by surgery. Regional brain activations were quantified using statistical parametric mapping (SPM). The correlation between the activations of the abnormal brain regions and the clinical seizure parameters were computed for LFLE patients. RESULTS Brain activations of LFLE patients were significantly elevated in left superior/middle/inferior frontal gyri, postcentral gyrus, inferior temporal gyrus, insula, parahippocampal gyrus and amygdala, including the epileptogenic regions. Remarkable decreased activations were found mainly in the left parietal gyrus and precuneus. There is a positive correlation between the duration of the epilepsy (in month) and activations of the abnormal regions, while no relation was found between age of seizure onset (year), seizure frequency and the regions of the abnormal activity of the epileptic patients. CONCLUSION Our findings suggest that the aberrant brain activities of LFLE patients were not restricted to the epileptogenic zones. Long duration of epilepsy might induce further functional damage in patients with LFLE.
Collapse
Affiliation(s)
- Haitao Zhu
- Department of Neurosurgery, Nanjing Brain Hospital Affiliated to Nanjing Medical University, Nanjing 210029, Jiangsu, China
| | - Jinlong Zhu
- Department of Neurosurgery, Nanjing Brain Hospital Affiliated to Nanjing Medical University, Nanjing 210029, Jiangsu, China
| | - Forrest Sheng Bao
- Department of Electrical and Computer Engineering, University of Akron, Akron, OH, USA
| | - Hongyi Liu
- Department of Neurosurgery, Nanjing Brain Hospital Affiliated to Nanjing Medical University, Nanjing 210029, Jiangsu, China
| | - Xuchuang Zhu
- Department of Neurosurgery, Nanjing Brain Hospital Affiliated to Nanjing Medical University, Nanjing 210029, Jiangsu, China
| | - Ting Wu
- MEG Center, Nanjing Brain Hospital Affiliated to Nanjing Medical University, Nanjing 210029, Jiangsu, China
| | - Lu Yang
- MEG Center, Nanjing Brain Hospital Affiliated to Nanjing Medical University, Nanjing 210029, Jiangsu, China
| | - Yuanjie Zou
- Department of Neurosurgery, Nanjing Brain Hospital Affiliated to Nanjing Medical University, Nanjing 210029, Jiangsu, China
| | - Rui Zhang
- Department of Neurosurgery, Nanjing Brain Hospital Affiliated to Nanjing Medical University, Nanjing 210029, Jiangsu, China.
| | - Gang Zheng
- Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing 210002, Jiangsu, China; College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, Jiangsu, China.
| |
Collapse
|
37
|
Hu Y, Mi X, Xu X, Fang W, Zeng K, Yang M, Li C, Wang S, Li M, Wang X. The Brain Activity in Brodmann Area 17: A Potential Bio-Marker to Predict Patient Responses to Antiepileptic Drugs. PLoS One 2015; 10:e0139819. [PMID: 26439500 PMCID: PMC4595505 DOI: 10.1371/journal.pone.0139819] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2014] [Accepted: 07/28/2015] [Indexed: 12/29/2022] Open
Abstract
In this study, we aimed to predict newly diagnosed patient responses to antiepileptic drugs (AEDs) using resting-state functional magnetic resonance imaging tools to explore changes in spontaneous brain activity. We recruited 21 newly diagnosed epileptic patients, 8 drug-resistant (DR) patients, 11 well-healed (WH) patients, and 13 healthy controls. After a 12-month follow-up, 11 newly diagnosed epileptic patients who showed a poor response to AEDs were placed into the seizures uncontrolled (SUC) group, while 10 patients were enrolled in the seizure-controlled (SC) group. By calculating the amplitude of fractional low-frequency fluctuations (fALFF) of blood oxygen level-dependent signals to measure brain activity during rest, we found that the SUC patients showed increased activity in the bilateral occipital lobe, particularly in the cuneus and lingual gyrus compared with the SC group and healthy controls. Interestingly, DR patients also showed increased activity in the identical cuneus and lingual gyrus regions, which comprise Brodmann's area 17 (BA17), compared with the SUC patients; however, these abnormalities were not observed in SC and WH patients. The receiver operating characteristic (ROC) curves indicated that the fALFF value of BA17 could differentiate SUC patients from SC patients and healthy controls with sufficient sensitivity and specificity prior to the administration of medication. Functional connectivity analysis was subsequently performed to evaluate the difference in connectivity between BA17 and other brain regions in the SUC, SC and control groups. Regions nearby the cuneus and lingual gyrus were found positive connectivity increased changes or positive connectivity changes with BA17 in the SUC patients, while remarkably negative connectivity increased changes or positive connectivity decreased changes were found in the SC patients. Additionally, default mode network (DMN) regions showed negative connectivity increased changes or negative changes with BA17 in the SUC patients. The abnormal increased in BA17 activity may be a key point that plays a substantial role in facilitating seizure onset.
Collapse
Affiliation(s)
- Yida Hu
- Department of Neurology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, People’s Republic of China
| | - Xiujuan Mi
- Department of Neurology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, People’s Republic of China
| | - Xin Xu
- Department of Neurology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, People’s Republic of China
| | - Weidong Fang
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, People’s Republic of China
| | - Kebin Zeng
- Department of Neurology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, People’s Republic of China
| | - Mingming Yang
- Department of Pediatrics, Chongqing City Hospital of Traditional Chinese Medicine, Chongqing, People’s Republic of China
| | - Chenyu Li
- Department of Neurology, Chongqing City Hospital of Traditional Chinese Medicine, Chongqing, People’s Republic of China
| | - Shasha Wang
- The Nursing Department, Chongqing Three Gorges Central Hospital, Chongqing, People’s Republic of China
| | - Minghui Li
- The Nursing Department, First Hospital of Shanxi Medical University, Taiyuan, People’s Republic of China
| | - Xuefeng Wang
- Department of Neurology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, People’s Republic of China
- * E-mail:
| |
Collapse
|
38
|
Stylianou P, Hoffmann C, Blat I, Harnof S. Neuroimaging for patient selection for medial temporal lobe epilepsy surgery: Part 1 Structural neuroimaging. J Clin Neurosci 2015; 23:14-22. [PMID: 26362835 DOI: 10.1016/j.jocn.2015.04.019] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2015] [Revised: 03/27/2015] [Accepted: 04/05/2015] [Indexed: 11/19/2022]
Abstract
The objective of part one of this review is to present the structural neuroimaging techniques that are currently used to evaluate patients with temporal lobe epilepsy (TLE), and to discuss their potential to define patient eligibility for medial temporal lobe surgery. A PubMed query, using Medline and Embase, and subsequent review, was performed for all English language studies published after 1990, reporting neuroimaging methods for the evaluation of patients with TLE. The extracted data included demographic variables, population and study design, imaging methods, gold standard methods, imaging findings, surgical outcomes and conclusions. Overall, 56 papers were reviewed, including a total of 1517 patients. This review highlights the following structural neuroimaging techniques: MRI, diffusion-weighted imaging, tractography, electroencephalography and magnetoencephalography. The developments in neuroimaging during the last decades have led to remarkable improvements in surgical precision, postsurgical outcome, prognosis, and the rate of seizure control in patients with TLE. The use of multiple imaging methods provides improved outcomes, and further improvements will be possible with future studies of larger patient cohorts.
Collapse
Affiliation(s)
- Petros Stylianou
- Department of Neurosurgery, The Chaim Sheba Medical Center, Nissim Aloni 16, Tel Aviv-Yafo 62919, Israel.
| | - Chen Hoffmann
- Department of Radiology, The Chaim Sheba Medical Center, Tel Hashomer, Israel
| | - Ilan Blat
- Department of Neurology, The Chaim Sheba Medical Center, Tel Hashomer, Israel
| | - Sagi Harnof
- Department of Neurosurgery, The Chaim Sheba Medical Center, Nissim Aloni 16, Tel Aviv-Yafo 62919, Israel
| |
Collapse
|
39
|
Ictal Magnetic Source Imaging in Presurgical Assessment. Brain Topogr 2015; 29:182-92. [PMID: 26264375 DOI: 10.1007/s10548-015-0445-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2014] [Accepted: 08/06/2015] [Indexed: 10/23/2022]
Abstract
Ictal MEG recordings constitute rare data. The objective of this study was to evaluate ictal magnetic source localization (MSI), using two algorithms: linearly constrained minimum variance (LCMV), a beamforming technique and equivalent current dipole (ECD). Ictal MSI was studied in six patients. Three of them were undergoing post-operative re-evaluation. For all patients, results were validated by the stereoelectroencephalographic (SEEG) definition of the epileptogenic zone (EZ). EZ was quantified using the epileptogenicity index (EI) method, which accounts for both the propensity of a brain area to generate rapid discharges and the time for this area to become involved in the seizure. EI values range from 0 (no epileptogenicity) to 1 (maximal epileptogenicity). Levels of concordance between ictal MSI and EZ were determined as follows: A: ictal MSI localized the site whose value EI = 1, B: MSI localized a part of the EZ (not corresponding to the maximal value of EI = 1), C: a region could be identified on ictal MSI but not on SEEG, D: a region could be identified on SEEG but not on MSI, E: different regions were localized on MSI and SEEG. Ictal MEG pattern consisted of rhythmic activities between 10 and 20 Hz for all patients. For LCMV (first maxima), levels of concordance were A (two cases), B (two cases) and E (two cases). For ECD fitted on each time point separately (location characterized by the best goodness-of-fit value), levels of concordance were A (one case), B (one case), D (three cases) and E (one case). For ECD calculated for the whole time window, levels of concordance were A (two cases) and D (four cases). Source localization methods performed on rhythmic patterns can localize the EZ as validated by SEEG. In terms of concordance, LCMV was superior to ECD. In some cases, LCMV allows extraction of several maxima that could reflect ictal dynamics. In a medial temporal lobe epilepsy case, ictal MSI indicated an area of delayed propagation and was non-contributory to the presurgical assessment.
Collapse
|
40
|
Kharkar S, Knowlton R. Magnetoencephalography in the presurgical evaluation of epilepsy. Epilepsy Behav 2015; 46:19-26. [PMID: 25555504 DOI: 10.1016/j.yebeh.2014.11.029] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2014] [Revised: 11/24/2014] [Accepted: 11/27/2014] [Indexed: 11/27/2022]
Abstract
Magnetoencephalography (MEG) is an important tool in the presurgical evaluation of patients with medically refractory epilepsy. The appropriate utilization and interpretation of MEG studies can increase the proportion of patients who may be able to further pursue surgical evaluation, refine surgical planning, and potentially increase the probability of seizure freedom after surgery. The aim of this paper is to provide the reader with a comprehensive but accessible guide to MEG, with particular emphasis on acquiring a working knowledge of MEG analysis, identifying patient groups that are most likely to benefit, and clarifying the limitations of this technology.
Collapse
Affiliation(s)
| | - Robert Knowlton
- Department of Neurology, University of California at San Francisco, USA; Department of Radiology, University of California at San Francisco, USA; Department of Neurological Surgery, University of California at San Francisco, USA
| |
Collapse
|
41
|
Englot DJ, Nagarajan SS, Imber BS, Raygor KP, Honma SM, Mizuiri D, Mantle M, Knowlton RC, Kirsch HE, Chang EF. Epileptogenic zone localization using magnetoencephalography predicts seizure freedom in epilepsy surgery. Epilepsia 2015; 56:949-58. [PMID: 25921215 DOI: 10.1111/epi.13002] [Citation(s) in RCA: 98] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/18/2015] [Indexed: 12/01/2022]
Abstract
OBJECTIVE The efficacy of epilepsy surgery depends critically upon successful localization of the epileptogenic zone. Magnetoencephalography (MEG) enables noninvasive detection of interictal spike activity in epilepsy, which can then be localized in three dimensions using magnetic source imaging (MSI) techniques. However, the clinical value of MEG in the presurgical epilepsy evaluation is not fully understood, as studies to date are limited by either a lack of long-term seizure outcomes or small sample size. METHODS We performed a retrospective cohort study of patients with focal epilepsy who received MEG for interictal spike mapping followed by surgical resection at our institution. RESULTS We studied 132 surgical patients, with mean postoperative follow-up of 3.6 years (minimum 1 year). Dipole source modeling was successful in 103 patients (78%), whereas no interictal spikes were seen in others. Among patients with successful dipole modeling, MEG findings were concordant with and specific to the following: (1) the region of resection in 66% of patients, (2) invasive electrocorticography (ECoG) findings in 67% of individuals, and (3) the magnetic resonance imaging (MRI) abnormality in 74% of cases. MEG showed discordant lateralization in ~5% of cases. After surgery, 70% of all patients achieved seizure freedom (Engel class I outcome). Whereas 85% of patients with concordant and specific MEG findings became seizure-free, this outcome was achieved by only 37% of individuals with MEG findings that were nonspecific to or discordant with the region of resection (χ(2) = 26.4, p < 0.001). MEG reliability was comparable in patients with or without localized scalp electroencephalography (EEG), and overall, localizing MEG findings predicted seizure freedom with an odds ratio of 5.11 (95% confidence interval [CI] 2.23-11.8). SIGNIFICANCE MEG is a valuable tool for noninvasive interictal spike mapping in epilepsy surgery, including patients with nonlocalized findings receiving long-term EEG monitoring, and localization of the epileptogenic zone using MEG is associated with improved seizure outcomes.
Collapse
Affiliation(s)
- Dario J Englot
- UCSF Comprehensive Epilepsy Center, University of California, San Francisco, San Francisco, California, U.S.A.,Department of Neurological Surgery, University of California, San Francisco, San Francisco, California, U.S.A.,Biomagnetic Imaging Lab, Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, U.S.A
| | - Srikantan S Nagarajan
- UCSF Comprehensive Epilepsy Center, University of California, San Francisco, San Francisco, California, U.S.A.,Biomagnetic Imaging Lab, Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, U.S.A
| | - Brandon S Imber
- UCSF Comprehensive Epilepsy Center, University of California, San Francisco, San Francisco, California, U.S.A.,Department of Neurological Surgery, University of California, San Francisco, San Francisco, California, U.S.A
| | - Kunal P Raygor
- UCSF Comprehensive Epilepsy Center, University of California, San Francisco, San Francisco, California, U.S.A.,Department of Neurological Surgery, University of California, San Francisco, San Francisco, California, U.S.A
| | - Susanne M Honma
- Biomagnetic Imaging Lab, Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, U.S.A
| | - Danielle Mizuiri
- Biomagnetic Imaging Lab, Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, U.S.A
| | - Mary Mantle
- UCSF Comprehensive Epilepsy Center, University of California, San Francisco, San Francisco, California, U.S.A.,Biomagnetic Imaging Lab, Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, U.S.A
| | - Robert C Knowlton
- UCSF Comprehensive Epilepsy Center, University of California, San Francisco, San Francisco, California, U.S.A.,Biomagnetic Imaging Lab, Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, U.S.A.,Department of Neurology, University of California, San Francisco, San Francisco, California, U.S.A
| | - Heidi E Kirsch
- UCSF Comprehensive Epilepsy Center, University of California, San Francisco, San Francisco, California, U.S.A.,Biomagnetic Imaging Lab, Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, U.S.A.,Department of Neurology, University of California, San Francisco, San Francisco, California, U.S.A
| | - Edward F Chang
- UCSF Comprehensive Epilepsy Center, University of California, San Francisco, San Francisco, California, U.S.A.,Department of Neurological Surgery, University of California, San Francisco, San Francisco, California, U.S.A.,Biomagnetic Imaging Lab, Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, U.S.A
| |
Collapse
|
42
|
Stapleton-Kotloski JR, Kotloski RJ, Boggs JA, Popli G, O'Donovan CA, Couture DE, Cornell C, Godwin DW. Localization of interictal epileptiform activity using magnetoencephalography with synthetic aperture magnetometry in patients with a vagus nerve stimulator. Front Neurol 2014; 5:244. [PMID: 25505894 PMCID: PMC4245924 DOI: 10.3389/fneur.2014.00244] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2014] [Accepted: 11/11/2014] [Indexed: 11/13/2022] Open
Abstract
Magnetoencephalography (MEG) provides useful and non-redundant information in the evaluation of patients with epilepsy, and in particular, during the pre-surgical evaluation of pharmaco-resistant epilepsy. Vagus nerve stimulation (VNS) is a common treatment for pharmaco-resistant epilepsy. However, interpretation of MEG recordings from patients with a VNS is challenging due to the severe magnetic artifacts produced by the VNS. We used synthetic aperture magnetometry (g2) [SAM(g2)], an adaptive beamformer that maps the excessive kurtosis, to map interictal spikes to the coregistered MRI image, despite the presence of contaminating VNS artifact. We present a series of eight patients with a VNS who underwent MEG recording. Localization of interictal epileptiform activity by SAM(g2) is compared to invasive electrophysiologic monitoring and other localizing approaches. While the raw MEG recordings were uninterpretable, analysis of the recordings with SAM(g2) identified foci of peak kurtosis and source signal activity that was unaffected by the VNS artifact. SAM(g2) analysis of MEG recordings in patients with a VNS produces interpretable results and expands the use of MEG for the pre-surgical evaluation of epilepsy.
Collapse
Affiliation(s)
| | - Robert J Kotloski
- Department of Neurology, William S. Middleton Memorial Veterans Hospital , Madison, WI , USA ; Department of Neurology, University of Wisconsin School of Medicine and Public Health , Madison, WI , USA
| | - Jane A Boggs
- Department of Neurology, Wake Forest University School of Medicine , Winston-Salem, NC , USA
| | - Gautam Popli
- Department of Neurology, Wake Forest University School of Medicine , Winston-Salem, NC , USA
| | - Cormac A O'Donovan
- Department of Neurology, Wake Forest University School of Medicine , Winston-Salem, NC , USA
| | - Daniel E Couture
- Department of Neurosurgery, Wake Forest University School of Medicine , Winston-Salem, NC , USA
| | - Cassandra Cornell
- Department of Neurology, Wake Forest University School of Medicine , Winston-Salem, NC , USA
| | - Dwayne W Godwin
- Department of Neurology, Wake Forest University School of Medicine , Winston-Salem, NC , USA ; Department of Neurobiology and Anatomy, Wake Forest University School of Medicine , Winston-Salem, NC , USA
| |
Collapse
|
43
|
|
44
|
Almubarak S, Alexopoulos A, Von-Podewils F, Wang ZI, Kakisaka Y, Mosher JC, Bulacio J, González-Martínez J, Bingaman W, Burgess RC. The correlation of magnetoencephalography to intracranial EEG in localizing the epileptogenic zone: A study of the surgical resection outcome. Epilepsy Res 2014; 108:1581-90. [DOI: 10.1016/j.eplepsyres.2014.08.016] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2014] [Revised: 07/20/2014] [Accepted: 08/21/2014] [Indexed: 11/27/2022]
|
45
|
Magnetic Source Imaging in Posterior Cortex Epilepsies. Brain Topogr 2014; 28:162-71. [DOI: 10.1007/s10548-014-0412-4] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2014] [Accepted: 10/20/2014] [Indexed: 11/27/2022]
|
46
|
Comparison of magnetic source estimation to intracranial EEG, resection area, and seizure outcome. Epilepsia 2014; 55:1854-63. [DOI: 10.1111/epi.12822] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/02/2014] [Indexed: 11/26/2022]
|
47
|
Wavelet-Based Localization of Oscillatory Sources From Magnetoencephalography Data. IEEE Trans Biomed Eng 2014; 61:2350-64. [DOI: 10.1109/tbme.2012.2189883] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
48
|
Xiang J, Luo Q, Kotecha R, Korman A, Zhang F, Luo H, Fujiwara H, Hemasilpin N, Rose DF. Accumulated source imaging of brain activity with both low and high-frequency neuromagnetic signals. Front Neuroinform 2014; 8:57. [PMID: 24904402 PMCID: PMC4033602 DOI: 10.3389/fninf.2014.00057] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2013] [Accepted: 05/02/2014] [Indexed: 11/27/2022] Open
Abstract
Recent studies have revealed the importance of high-frequency brain signals (>70 Hz). One challenge of high-frequency signal analysis is that the size of time-frequency representation of high-frequency brain signals could be larger than 1 terabytes (TB), which is beyond the upper limits of a typical computer workstation's memory (<196 GB). The aim of the present study is to develop a new method to provide greater sensitivity in detecting high-frequency magnetoencephalography (MEG) signals in a single automated and versatile interface, rather than the more traditional, time-intensive visual inspection methods, which may take up to several days. To address the aim, we developed a new method, accumulated source imaging, defined as the volumetric summation of source activity over a period of time. This method analyzes signals in both low- (1~70 Hz) and high-frequency (70~200 Hz) ranges at source levels. To extract meaningful information from MEG signals at sensor space, the signals were decomposed to channel-cross-channel matrix (CxC) representing the spatiotemporal patterns of every possible sensor-pair. A new algorithm was developed and tested by calculating the optimal CxC and source location-orientation weights for volumetric source imaging, thereby minimizing multi-source interference and reducing computational cost. The new method was implemented in C/C++ and tested with MEG data recorded from clinical epilepsy patients. The results of experimental data demonstrated that accumulated source imaging could effectively summarize and visualize MEG recordings within 12.7 h by using approximately 10 GB of computer memory. In contrast to the conventional method of visually identifying multi-frequency epileptic activities that traditionally took 2–3 days and used 1–2 TB storage, the new approach can quantify epileptic abnormalities in both low- and high-frequency ranges at source levels, using much less time and computer memory.
Collapse
Affiliation(s)
- Jing Xiang
- Division of Neurology, MEG Center, Cincinnati Children's Hospital Medical Center Cincinnati, OH, USA
| | - Qian Luo
- Department of Neurosurgery, Saint Louis University St. Louis, MO, USA
| | - Rupesh Kotecha
- Division of Neurology, MEG Center, Cincinnati Children's Hospital Medical Center Cincinnati, OH, USA ; Cleveland Clinic Foundation, Department of Radiation Oncology Cleveland, OH, USA
| | - Abraham Korman
- Division of Neurology, MEG Center, Cincinnati Children's Hospital Medical Center Cincinnati, OH, USA
| | - Fawen Zhang
- Department of Communication Sciences and Disorders, University of Cincinnati Cincinnati, OH, USA
| | - Huan Luo
- State Key Laboratory of Brain and Cognitive Science, Institute of Biophysics, Chinese Academy of Sciences Beijing, China
| | - Hisako Fujiwara
- Division of Neurology, MEG Center, Cincinnati Children's Hospital Medical Center Cincinnati, OH, USA
| | - Nat Hemasilpin
- Division of Neurology, MEG Center, Cincinnati Children's Hospital Medical Center Cincinnati, OH, USA
| | - Douglas F Rose
- Division of Neurology, MEG Center, Cincinnati Children's Hospital Medical Center Cincinnati, OH, USA
| |
Collapse
|
49
|
Can we increase the yield of FDG-PET in the preoperative work-up for epilepsy surgery? Epilepsy Res 2014; 108:1095-105. [PMID: 24893829 DOI: 10.1016/j.eplepsyres.2014.04.011] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2013] [Revised: 04/15/2014] [Accepted: 04/27/2014] [Indexed: 11/21/2022]
Abstract
PURPOSE [(18)F] Fluorodeoxyglucose Positron Emission Tomography (FDG-PET) is a semi-invasive, interictal method of localization of hypometabolic epileptic foci. FDG-PET can be useful in the clinical work-up prior to epilepsy surgery, especially in equivocal cases. We investigated whether we could increase the yield of presurgical FDG-PET in patients with difficult epilepsy requiring chronic subdural electrocorticography (ECoG). METHODS We retrospectively studied patients with refractory focal epilepsy in whom there was uncertainty about the focus localization and who underwent FDG-PET and ECoG. Two experts (epileptologist and nuclear medicine radiologist) together systematically re-assessed the scans visually (PETRE), blinded to their initial reports. Scans were also re-analyzed by comparing them to a normal control dataset with Statistical Parametric Mapping (SPM), using a liberal (PETSPM1), and strict (PETSPM2) statistical threshold. Regions with hypometabolism and regions containing the seizure onset zone (SOZ) in ECoG were marked as positive anatomical regions (PARs). We compared the concordance of these PARs for the different PET re-assessments. We calculated the sensitivity, specificity and accuracy of the PET results for the SOZ. The added value of the re-assessments was evaluated with emphasis on scans initially reported as negative. RESULTS 41 Patients (63% extra-temporal) were included. PETRE identified the SOZ best, with a sensitivity of 62% and specificity of 93%. PETSPM1 had a sensitivity of 62% and specificity 69%, for PETSPM2 this was 35% and 85% respectively. The overlap between PETRE vs. PETSPM1 and vs. PETSPM2 was 71% and 37%. Visual re-assessment and PETSPM1 identified the SOZ in four out of five scans that were initially reported as negative. CONCLUSIONS Pre-surgical re-assessment of PET scans is worthwhile in epilepsy patients who undergo ECoG, especially when results were reported as negative before. Visual re-assessment itself has a higher combined specificity, sensitivity and accuracy than SPM analysis alone. SPM analysis could be used as a guide for visual (re-)assessment, because of its high sensitivity.
Collapse
|
50
|
Pittau F, Grouiller F, Spinelli L, Seeck M, Michel CM, Vulliemoz S. The role of functional neuroimaging in pre-surgical epilepsy evaluation. Front Neurol 2014. [PMID: 24715886 DOI: 10.3389/fneur.2014.00031.] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
The prevalence of epilepsy is about 1% and one-third of cases do not respond to medical treatment. In an eligible subset of patients with drug-resistant epilepsy, surgical resection of the epileptogenic zone is the only treatment that can possibly cure the disease. Non-invasive techniques provide information for the localization of the epileptic focus in the majority of cases, whereas in others invasive procedures are required. In the last years, non-invasive neuroimaging techniques, such as simultaneous recording of functional magnetic resonance imaging and electroencephalogram (EEG-fMRI), positron emission tomography (PET), single photon emission computed tomography (SPECT), electric and magnetic source imaging (MSI, ESI), spectroscopy (MRS), have proved their usefulness in defining the epileptic focus. The combination of these functional techniques can yield complementary information and their concordance is crucial for guiding clinical decision, namely the planning of invasive EEG recordings or respective surgery. The aim of this review is to present these non-invasive neuroimaging techniques, their potential combination, and their role in the pre-surgical evaluation of patients with pharmaco-resistant epilepsy.
Collapse
Affiliation(s)
- Francesca Pittau
- Presurgical Epilepsy Evaluation Unit, Neurology Department, University Hospital of Geneva , Geneva , Switzerland
| | - Frédéric Grouiller
- Department of Radiology and Medical Informatics, University Hospital of Geneva , Geneva , Switzerland
| | - Laurent Spinelli
- Presurgical Epilepsy Evaluation Unit, Neurology Department, University Hospital of Geneva , Geneva , Switzerland
| | - Margitta Seeck
- Presurgical Epilepsy Evaluation Unit, Neurology Department, University Hospital of Geneva , Geneva , Switzerland
| | - Christoph M Michel
- Functional Brain Mapping Laboratory, Department of Fundamental Neurosciences, University of Geneva , Geneva , Switzerland
| | - Serge Vulliemoz
- Presurgical Epilepsy Evaluation Unit, Neurology Department, University Hospital of Geneva , Geneva , Switzerland
| |
Collapse
|