1
|
Marchesini V, Corlette S, Sheppard S, Davidson A, Tingay D. Evaluation of lung homogeneity in neonates and small infants during general anaesthesia using electrical impedance tomography: a prospective observational study. BJA OPEN 2024; 12:100344. [PMID: 39364288 PMCID: PMC11447312 DOI: 10.1016/j.bjao.2024.100344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2024] [Accepted: 08/28/2024] [Indexed: 10/05/2024]
Abstract
Background Prolonged mechanical ventilation can create heterogeneous ventilation patterns, which increase the risk of lung injury in infants. However, little is understood about the risk of brief exposure to mechanical ventilation during anaesthesia. The aim of this prospective observational study was to describe the regional pattern of lung ventilation during general anaesthesia in healthy neonates and infants, using electrical impedance tomography. Methods Twenty infants (age 3 days to 12 months), without known lung disease and receiving general anaesthesia with endotracheal intubation for supine positioned surgery, were included in the study. Anaesthesia and ventilation management was at the discretion of the treating clinician. Standardised lung imaging using electrical impedance tomography was made at six time points during anaesthesia from induction to post-extubation. At each time point, the gravity-dependent and right-left lung centre of ventilation was calculated. Results Tidal ventilation favoured the dorsal lung regions at induction, with a median (inter-quartile range) centre of ventilation (CoV) of 58.2 (53.9-59.3)%. After intubation, there was a redistribution of ventilation to the ventral lung, with the greatest change occurring early in surgery: CoV of 53.8 (52.3-55.2)%. After extubation, CoV returned to pre-intubation values: 56.5 (54.7-58)%. Across all time points, the pattern of ventilation favoured the right lung. Conclusions General anaesthesia creates heterogenous patterns of ventilation similar to those reported during prolonged mechanical ventilation. This potentially poses a risk for lung injury that may not be recognised clinically. These results suggest the need to better understand the impact of general anaesthesia on the developing lung. Clinical trial registration Australian New Zealand Clinical Trials Registry (ACTRN 12616000818437, 22 June 2016).
Collapse
Affiliation(s)
- Vanessa Marchesini
- Department of Anaesthesia and Pain Management, The Royal Children's Hospital, Parkville, Melbourne, VIC, Australia
- Department of Anaesthesia, Murdoch Children's Research Institute, Parkville, Melbourne, VIC, Australia
| | - Sebastian Corlette
- Department of Anaesthesia and Pain Management, The Royal Children's Hospital, Parkville, Melbourne, VIC, Australia
- Department of Anaesthesia, Murdoch Children's Research Institute, Parkville, Melbourne, VIC, Australia
- Department of Paediatrics, University of Melbourne, Melbourne, VIC, Australia
| | - Suzette Sheppard
- Department of Anaesthesia, Murdoch Children's Research Institute, Parkville, Melbourne, VIC, Australia
| | - Andrew Davidson
- Department of Anaesthesia and Pain Management, The Royal Children's Hospital, Parkville, Melbourne, VIC, Australia
- Department of Anaesthesia, Murdoch Children's Research Institute, Parkville, Melbourne, VIC, Australia
- Department of Paediatrics, University of Melbourne, Melbourne, VIC, Australia
| | - David Tingay
- Department of Paediatrics, University of Melbourne, Melbourne, VIC, Australia
- Department of Neonatology, Royal Children's Hospital, Parkville, Melbourne, VIC, Australia
- Neonatal Research, Murdoch Children's Research Institute, Parkville, VIC, Australia
| |
Collapse
|
2
|
Muñoz J, Cedeño JA, Castañeda GF, Visedo LC. Personalized ventilation adjustment in ARDS: A systematic review and meta-analysis of image, driving pressure, transpulmonary pressure, and mechanical power. Heart Lung 2024; 68:305-315. [PMID: 39214040 DOI: 10.1016/j.hrtlng.2024.08.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 06/28/2024] [Accepted: 08/16/2024] [Indexed: 09/04/2024]
Abstract
BACKGROUND Acute Respiratory Distress Syndrome (ARDS) necessitates personalized treatment strategies due to its heterogeneity, aiming to mitigate Ventilator-Induced Lung Injury (VILI). Advanced monitoring techniques, including imaging, driving pressure, transpulmonary pressure, and mechanical power, present potential avenues for tailored interventions. OBJECTIVE To review some of the most important techniques for achieving greater personalization of mechanical ventilation in ARDS patients as evaluated in randomized clinical trials, by analyzing their effect on three clinically relevant aspects: mortality, ventilator-free days, and gas exchange. METHODS Following PRISMA guidelines, we conducted a systematic review and meta-analysis of Randomized Clinical Trials (RCTs) involving adult ARDS patients undergoing personalized ventilation adjustments. Outcomes were mortality (primary end-point), ventilator-free days, and oxygenation improvement. RESULTS Among 493 identified studies, 13 RCTs (n = 1255) met inclusion criteria. No personalized ventilation strategy demonstrated superior outcomes compared to traditional protocols. Meta-analysis revealed no significant reduction in mortality with image-guided (RR 0.88, 95 % CI 0.70-1.11), driving pressure-guided (RR 0.61, 95 % CI 0.29-1.30), or transpulmonary pressure-guided (RR 0.85, 95 % CI 0.58-1.24) strategies. Ventilator-free days and oxygenation outcomes showed no significant differences. CONCLUSION Our study does not support the superiority of personalized ventilation techniques over traditional protocols in ARDS patients. Further research is needed to standardize ventilation strategies and determine their impact on mechanical ventilation outcomes.
Collapse
Affiliation(s)
- Javier Muñoz
- ICU, Hospital General Universitario Gregorio Marañón, C/ Dr. Esquedo 46, 28009 Madrid, Spain.
| | - Jamil Antonio Cedeño
- ICU, Hospital General Universitario Gregorio Marañón, C/ Dr. Esquedo 46, 28009 Madrid, Spain
| | | | - Lourdes Carmen Visedo
- C. S. San Juan de la Cruz, Pozuelo de Alarcón, C/ San Juan de la Cruz s/n, 28223 Madrid, Spain
| |
Collapse
|
3
|
Rozé H, Bonnardel E, Gallo E, Boisselier C, Khan P, Perrier V, Repusseau B, Brochard L. Inter-lung asymmetrical airway closure cause insufflation delay between lungs in acute hypoxemic respiratory failure. Ann Intensive Care 2024; 14:162. [PMID: 39441425 PMCID: PMC11499510 DOI: 10.1186/s13613-024-01379-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2024] [Accepted: 09/10/2024] [Indexed: 10/25/2024] Open
Abstract
BACKGROUND Electrical Impedance Tomography (EIT) can quantify ventilation in the two lungs and be used to measure the airway opening pressure (AOP) of each lung. Asymmetrical AOPs can cause inter-lung insufflation delay. OBJECTIVES To assess the relation between AOP asymmetry and inter-lung insufflation delay at different PEEP levels. METHODS Patients with acute hypoxemic respiratory failure and airway closure were included. Low-flow pressure-volume curves and EIT signal were recorded during controlled ventilation and for some patients in pressure support ventilation. RESULTS 23 patients were studied, 22 patients had ARDS, 9 patients had asymmetrical airway closure with an AOP of 10 [6-13] cmH20 in the sicker lung (AOPsicker) vs. 5 [3-9, ] cmH20 in the healthier lung. During a low flow inflation, the inter-lung inflation delay was 0 [0-112]ms vs. 1450 [375-2400]ms in patients without or with asymmetrical AOPs, p < 0.0001. This delay was correlated to the difference of AOP between the 2 lungs, Spearman R2 = 0.800, p < 0.0001. During tidal ventilation, median delay was 0 [0-62] ms vs. 150 [50-355] ms in patients without vs. with asymmetry, p = 0.019. Setting PEEP at the crossing point of a decremental EIT-based PEEP trial decreased the inter-lung insufflation delay. During pressure support insufflation delay could still be measured and was reduced by increasing PEEP from 5 to 10 cmH2O in patient with asymmetrical lung injury. CONCLUSION In asymmetrical airway closure, titrating PEEP can minimize inter-lung insufflation delay and can be monitored by EIT. Reducing the delay and reducing ventilation asymmetry is also feasible during pressure support ventilation when low flow inflation curves cannot be performed.
Collapse
Affiliation(s)
- Hadrien Rozé
- Réanimation Polyvalente, Centre Hospitalier Côte Basque, Bayonne, F-64100, France.
- CHU de Bordeaux, Service d'Anesthésie-Réanimation Thoraco-Abdominale, Pessac, F-33600, France.
- Université de Bordeaux, Talence, F-33400, France.
| | - Eline Bonnardel
- CHU de Bordeaux, Service d'Anesthésie-Réanimation Thoraco-Abdominale, Pessac, F-33600, France
| | - Eloise Gallo
- CHU de Bordeaux, Service d'Anesthésie-Réanimation Thoraco-Abdominale, Pessac, F-33600, France
| | - Clément Boisselier
- CHU de Bordeaux, Service d'Anesthésie-Réanimation Thoraco-Abdominale, Pessac, F-33600, France
| | - Pierre Khan
- CHU de Bordeaux, Service d'Anesthésie-Réanimation Thoraco-Abdominale, Pessac, F-33600, France
| | - Virginie Perrier
- CHU de Bordeaux, Service d'Anesthésie-Réanimation Thoraco-Abdominale, Pessac, F-33600, France
| | - Benjamin Repusseau
- CHU de Bordeaux, Service d'Anesthésie-Réanimation Thoraco-Abdominale, Pessac, F-33600, France
| | - Laurent Brochard
- Keenan Research Centre, Li Ka Shing Knowledge Institute, St Michael's Hospital, Toronto, Canada
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada
| |
Collapse
|
4
|
Wisse JJ, Scaramuzzo G, Pellegrini M, Heunks L, Piraino T, Somhorst P, Brochard L, Mauri T, Ista E, Jonkman AH. Clinical implementation of advanced respiratory monitoring with esophageal pressure and electrical impedance tomography: results from an international survey and focus group discussion. Intensive Care Med Exp 2024; 12:93. [PMID: 39432136 PMCID: PMC11493933 DOI: 10.1186/s40635-024-00686-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2024] [Accepted: 10/10/2024] [Indexed: 10/22/2024] Open
Abstract
BACKGROUND Popularity of electrical impedance tomography (EIT) and esophageal pressure (Pes) monitoring in the ICU is increasing, but there is uncertainty regarding their bedside use within a personalized ventilation strategy. We aimed to gather insights about the current experiences and perceived role of these physiological monitoring techniques, and to identify barriers and facilitators/solutions for EIT and Pes implementation. METHODS Qualitative study involving (1) a survey targeted at ICU clinicians with interest in advanced respiratory monitoring and (2) an expert focus group discussion. The survey was shared via international networks and personal communication. An in-person discussion session on barriers, facilitators/solutions for EIT implementation was organized with an international panel of EIT experts as part of a multi-day EIT meeting. Pes was not discussed in-person, but we found the focus group results relevant to Pes as well. This was confirmed by the survey results and four additional Pes experts that were consulted. RESULTS We received 138 survey responses, and 26 experts participated in the in-person discussion. Survey participants had diverse background [physicians (54%), respiratory therapists (19%), clinical researchers (15%), and nurses (6%)] with mostly > 10 year ICU experience. 84% of Pes users and 74% of EIT users rated themselves as competent to expert users. Techniques are currently primarily used during controlled ventilation for individualization of PEEP (EIT and Pes), and for monitoring lung mechanics and lung stress (Pes). EIT and Pes are considered relevant techniques to guide ventilation management and is helpful for educating clinicians; however, 57% of EIT users and 37% of Pes users agreed that further validation is needed. Lack of equipment/materials, evidence-based guidelines, clinical protocols, and/or the time-consuming nature of the measurements are main reasons hampering Pes and EIT application. Identified facilitators/solutions to improve implementation include international guidelines and collaborations between clinicians/researcher and manufacturers, structured courses for training and use, easy and user-friendly devices and standardized analysis pipelines. CONCLUSIONS This study revealed insights on the role and implementation of advanced respiratory monitoring with EIT and Pes. The identified barriers, facilitators and strategies can serve as input for further discussions to promote the development of EIT-guided or Pes-guided personalized ventilation strategies.
Collapse
Affiliation(s)
- Jantine J Wisse
- Adult Intensive Care, Erasmus Medical Center, Dr. Molewaterplein 40, 3015GD, Rotterdam, The Netherlands
- Department of Neonatal and Pediatric Intensive Care, Division of Neonatology, Erasmus Medical Center, Sophia Children's Hospital, Rotterdam, The Netherlands
| | - Gaetano Scaramuzzo
- Department of Translation Medicine, University of Ferrara, Ferrara, Italy
- Department of Emergency, Azienda Ospedaliera Universitaria Sant' Anna, Ferrara, Italy
| | - Mariangela Pellegrini
- Department of Surgical Sciences, Anaesthesiology and Intensive Care Medicine, Uppsala University, Uppsala, Sweden
| | - Leo Heunks
- Department of Intensive Care, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Thomas Piraino
- Department of Anesthesia, McMaster University, Hamilton, ON, Canada
| | - Peter Somhorst
- Adult Intensive Care, Erasmus Medical Center, Dr. Molewaterplein 40, 3015GD, Rotterdam, The Netherlands
| | - Laurent Brochard
- Keenan Centre for Biomedical Research, Li Ka Shing Knowledge Institute and St. Michael's Hospital, Unity Health Toronto, Toronto, ON, Canada
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, ON, Canada
| | - Tommaso Mauri
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Erwin Ista
- Department of Internal Medicine, Division of Nursing Science, Erasmus Medical Center, Rotterdam, The Netherlands
- Department of Neonatal and Pediatric Intensive Care, Division Pediatric Intensive Care, Erasmus Medical Center, Sophia Children's Hospital, Rotterdam, The Netherlands
| | - Annemijn H Jonkman
- Adult Intensive Care, Erasmus Medical Center, Dr. Molewaterplein 40, 3015GD, Rotterdam, The Netherlands.
| |
Collapse
|
5
|
Patel J, Weinberger B, Pulju M, Galanti SG, Kasniya G, Gupta V, Kurepa D. Lung Ultrasound Assessment of Regional Distribution of Pulmonary Edema and Atelectasis in Infants with Evolving Bronchopulmonary Dysplasia. Diagnostics (Basel) 2024; 14:2341. [PMID: 39451663 PMCID: PMC11506572 DOI: 10.3390/diagnostics14202341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2024] [Revised: 10/08/2024] [Accepted: 10/14/2024] [Indexed: 10/26/2024] Open
Abstract
Background: Preterm infants are at risk for bronchopulmonary dysplasia (BPD) due to prolonged respiratory support. Studies have described differences in the regional distribution of lung ventilation (non-dependent (NDL) vs. dependent (DL)). The aim of this study was to use LUS to compare regional distribution of pulmonary edema and atelectasis in infants with evolving BPD. Methods: We prospectively performed LUS in premature infants with evolving BPD. On each side, three lung areas (NDL/anterior, lateral, and DL/posterior) were examined for the presence of pulmonary edema and atelectasis. Pulmonary edema scores were assigned based on the number of B-lines, and atelectasis scores were assigned based on the presence/absence of atelectasis. Results: 38 premature infants were enrolled. The NDL showed more pulmonary edema and atelectasis compared to the DL (p = 0.003, p = 0.049, respectively) and compared to the lateral lung (p =< 0.001, p = 0.004, respectively). There was no difference between the lateral and DL (p = 0.188, p = 0.156, respectively). There was no difference between the right and the left lung (p = 0.223, p = 0.656, respectively). Conclusions: In this cohort of preterm infants with evolving BPD, lung disease was unevenly distributed, with more pulmonary edema and atelectasis in the NDL regions compared to the DL or lateral regions.
Collapse
Affiliation(s)
- Jimikumar Patel
- Division of Newborn Medicine, Department of Pediatrics, University of Mississippi Medical Center, 2500 North State Street, Jackson, MS 39216, USA;
| | - Barry Weinberger
- Division of Neonatal-Perinatal Medicine, Northwell Health, Cohen Children’s Medical Center, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, 269-71 76th Street, New York City, NY 11041, USA; (B.W.); (M.P.); (S.G.G.); (G.K.); (V.G.)
| | - Margaret Pulju
- Division of Neonatal-Perinatal Medicine, Northwell Health, Cohen Children’s Medical Center, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, 269-71 76th Street, New York City, NY 11041, USA; (B.W.); (M.P.); (S.G.G.); (G.K.); (V.G.)
| | - Stephanie G. Galanti
- Division of Neonatal-Perinatal Medicine, Northwell Health, Cohen Children’s Medical Center, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, 269-71 76th Street, New York City, NY 11041, USA; (B.W.); (M.P.); (S.G.G.); (G.K.); (V.G.)
| | - Gangajal Kasniya
- Division of Neonatal-Perinatal Medicine, Northwell Health, Cohen Children’s Medical Center, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, 269-71 76th Street, New York City, NY 11041, USA; (B.W.); (M.P.); (S.G.G.); (G.K.); (V.G.)
| | - Venkata Gupta
- Division of Neonatal-Perinatal Medicine, Northwell Health, Cohen Children’s Medical Center, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, 269-71 76th Street, New York City, NY 11041, USA; (B.W.); (M.P.); (S.G.G.); (G.K.); (V.G.)
| | - Dalibor Kurepa
- Division of Neonatal-Perinatal Medicine, Northwell Health, Cohen Children’s Medical Center, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, 269-71 76th Street, New York City, NY 11041, USA; (B.W.); (M.P.); (S.G.G.); (G.K.); (V.G.)
| |
Collapse
|
6
|
Alvarado-Arriagada F, Fernández-Arroyo B, Rebolledo S, Pino EJ. Development and Validation of a Portable EIT System for Real-Time Respiratory Monitoring. SENSORS (BASEL, SWITZERLAND) 2024; 24:6642. [PMID: 39460122 PMCID: PMC11511497 DOI: 10.3390/s24206642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2024] [Revised: 10/05/2024] [Accepted: 10/13/2024] [Indexed: 10/28/2024]
Abstract
This work contributes to the improvement of novel medical technologies for the prevention and treatment of diseases. Electrical impedance tomography (EIT) has gained attention as a valuable tool for non-invasive monitoring providing real-time insights. The purpose of this work is to develop and validate a novel portable EIT system with a small form factor for respiratory monitoring. The device uses a 16-electrode architecture with adjacent stimulation and measurement patterns, an integrated circuit current source and a single high-speed ADC operating with multiplexers to stimulate and measure across all electrodes. Tests were conducted on 25 healthy subjects who performed a pulmonary function test with a flowmeter while using the EIT device. The results showed a good performance of the device, which was able to recognize all respirations correctly, and from the EIT signals and images, correlations of 96.7% were obtained for instantaneous respiratory rate and 96.1% for tidal volume prediction. These results validate the preliminary technical feasibility of the EIT system and demonstrates its potential as a reliable tool for non-invasive respiratory assessment. The significance of this work lies in its potential to democratize advanced respiratory monitoring technologies, making them accessible to a wider population, including those in remote or underserved areas.
Collapse
Affiliation(s)
| | | | | | - Esteban J. Pino
- Department of Electrical Engineering, Faculty of Engineering, Universidad de Concepcion, 219 Edmundo Larenas, Concepción 4070409, Chile; (F.A.-A.); (B.F.-A.); (S.R.)
| |
Collapse
|
7
|
Francovich JE, Somhorst P, Gommers D, Endeman H, Jonkman AH. Physiological definition for region of interest selection in electrical impedance tomography data: description and validation of a novel method. Physiol Meas 2024; 45:105002. [PMID: 39317238 DOI: 10.1088/1361-6579/ad7f1f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Accepted: 09/24/2024] [Indexed: 09/26/2024]
Abstract
Objective. Geometrical region of interest (ROI) selection in electrical impedance tomography (EIT) monitoring may lack sensitivity to subtle changes in ventilation distribution. Therefore, we demonstrate a new physiological method for ROI definition. This is relevant when using ROIs to compute subsequent EIT-parameters, such as the ventral-to-dorsal ratio during a positive end-expiratory pressure (PEEP) trial.Approach.Our physiological approach divides an EIT image to ensure exactly 50% tidal impedance variation in the ventral and dorsal region. To demonstrate the effects of our new method, EIT measurements during a decremental PEEP trial in 49 mechanically ventilated ICU-patients were used. We compared the center of ventilation (CoV), a robust parameter for changes in ventro-dorsal ventilation distribution, to our physiological ROI selection method and different commonly used ROI selection methods. Moreover, we determined the impact of different ROI selection methods on the PEEP level corresponding to a ventral-to-dorsal ratio closest to 1.Main results.The division line separating the ventral and dorsal ROI was closer to the CoV for our new physiological method for ROI selection compared to geometrical ROI definition. Moreover, the PEEP level corresponding to a ventral-to-dorsal ratio of 1 is strongly influenced by the chosen ROI selection method, which could have a profound clinical impact; the within-subject range of PEEP level was 6.2 cmH2O depending on the chosen ROI selection method.Significance.Our novel physiological method for ROI definition is sensitive to subtle ventilation-induced changes in regional impedance (i.e. due to (de)recruitment) during mechanical ventilation, similar to the CoV.
Collapse
Affiliation(s)
- Juliette E Francovich
- Intensive Care, Erasmus Medical Center, Rotterdam, The Netherlands
- Educational program Technical Medicine, Leiden University Medical Center, Delft University of Technology & Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Peter Somhorst
- Intensive Care, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Diederik Gommers
- Intensive Care, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Henrik Endeman
- Intensive Care, Erasmus Medical Center, Rotterdam, The Netherlands
| | | |
Collapse
|
8
|
Fossali T, Locatelli M, Colombo R, Veronese A, Borghi B, Ballone E, Castelli A, Rech R, Catena E, Ottolina D. Awake pronation with helmet CPAP in early COVID-19 ARDS patients: effects on respiratory effort and distribution of ventilation assessed by EIT. Intern Emerg Med 2024; 19:2025-2034. [PMID: 38532048 DOI: 10.1007/s11739-024-03572-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 02/27/2024] [Indexed: 03/28/2024]
Abstract
Prone positioning with continuous positive airway pressure (CPAP) is widely used for respiratory support in awake patients with COVID-19-associated acute respiratory failure. We aimed to assess the respiratory mechanics and distribution of ventilation in COVID-19-associated ARDS treated by CPAP in awake prone position. We studied 16 awake COVID-19 patients with moderate-to-severe ARDS. The study protocol consisted of a randomized sequence of supine and prone position with imposed positive end-expiratory pressure (PEEP) of 5 and 10 cmH2O delivered by helmet CPAP. Respiratory mechanics and distribution of ventilation were assessed through esophageal pressure (PES) and electrical impedance tomography (EIT). At the end of each 20-min phase, arterial blood gas analysis was performed, and PES swing and EIT tracings were recorded for the calculation of the respiratory mechanics and regional ventilation. The patient's position had no significant effects on respiratory mechanics. EIT analysis did not detect differences among global indices of ventilation. A significant proportion of pixels in the sternal region of interest showed an increase in compliance from the supine to prone position and PaO2/FIO2 increased accordingly. The best improvement of both PaO2/FIO2 and sternal compliance was obtained in the prone position with PEEP 10 cmH2O. In the studied subjects, prone positioning during CPAP treatment raised oxygenation without improvement of "protective" ventilation or global ventilatory inhomogeneity indices. Prone positioning with higher PEEP significantly increased the compliance of sternal regions.
Collapse
Affiliation(s)
- Tommaso Fossali
- Department of Anesthesiology and Intensive Care, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, University of Milan, Via G.B. Grassi, 74, 20157, Milan, Italy
| | - Martina Locatelli
- Department of Anesthesiology and Intensive Care, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, University of Milan, Via G.B. Grassi, 74, 20157, Milan, Italy
| | - Riccardo Colombo
- Department of Anesthesiology and Intensive Care, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, University of Milan, Via G.B. Grassi, 74, 20157, Milan, Italy
| | - Alice Veronese
- Department of Anesthesiology and Intensive Care, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, University of Milan, Via G.B. Grassi, 74, 20157, Milan, Italy
| | - Beatrice Borghi
- Department of Anesthesiology and Intensive Care, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, University of Milan, Via G.B. Grassi, 74, 20157, Milan, Italy
| | - Elisabetta Ballone
- Department of Anesthesiology and Intensive Care, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, University of Milan, Via G.B. Grassi, 74, 20157, Milan, Italy
| | - Antonio Castelli
- Department of Anesthesiology and Intensive Care, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, University of Milan, Via G.B. Grassi, 74, 20157, Milan, Italy
| | - Roberto Rech
- Department of Anesthesiology and Intensive Care, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, University of Milan, Via G.B. Grassi, 74, 20157, Milan, Italy
| | - Emanuele Catena
- Department of Anesthesiology and Intensive Care, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, University of Milan, Via G.B. Grassi, 74, 20157, Milan, Italy
| | - Davide Ottolina
- Department of Anesthesiology and Intensive Care, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, University of Milan, Via G.B. Grassi, 74, 20157, Milan, Italy.
| |
Collapse
|
9
|
Louis B, Cour M, Argaud L, Guérin C. The Impact of PEEP on Ventilation Distribution in ARDS. Respir Care 2024; 69:1231-1238. [PMID: 39013571 PMCID: PMC11469017 DOI: 10.4187/respcare.11569] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/18/2024]
Abstract
BACKGROUND The first aim of this study was to evaluate the capacity of electrical impedance tomography (EIT) to identify the effect of PEEP on regional ventilation distribution and the regional risk of collapse, overdistention, hypoventilation, and pendelluft in mechanically ventilated patients. The second aim was to evaluate the feasibility of EIT for estimating airway opening pressure (AOP). METHODS The EIT signal was recorded both during baseline cyclic ventilation and slow insufflation for one breath for 9 subjects with moderate-to-severe ARDS. From these data, the AOP and volumes insufflated to lung regions with or without the risk of either collapse, overdistention, hypoventilation, or pendelluft were assessed at 3 PEEP levels (5, 10, and 15 cm H2O). PEEP levels were compared by Friedman analysis of variance and the AOP measured by EIT evaluated using an F-test and the Bland and Altman method. RESULTS The volume for which there was no specific risk significantly decreased at the highest PEEP from 55 ± 31% tidal volume (VT) at PEEP 5 or 82 ± 18% VT at PEEP 10 to 10 ± 30% VT at PEEP 15 (P = .038 between PEEP 5 vs PEEP 15; P = .01 between PEEP 10 vs PEEP 15). The volume associated with overdistention significantly increased with increasing PEEP, whereas that associated with atelectrauma significantly decreased. Pendelluft significantly decreased with increasing PEEP: VT of 8.9 ± 18.6%, 3.6 ± 7.0%, and 3.2 ± 7.1% for PEEP 5, PEEP 10, and PEEP 15, respectively. The center of ventilation tended to increase in the dependent direction with higher PEEP. The AOPs assessed by EIT and from the pressure-volume curve were in good agreement (bias 0.48 cm H2O). CONCLUSIONS Our results suggest that EIT could aid clinicians in making personalized and reasoned choices in setting the PEEP for subjects with ARDS.
Collapse
Affiliation(s)
- Bruno Louis
- Institut Mondor de Recherches Biomédicales INSERM-UPEC U955 CNRS EMR7000, Créteil, France.
| | - Martin Cour
- Médecine Intensive-Réanimation, Hôpital Edouard Herriot, Lyon, France
| | - Laurent Argaud
- Médecine Intensive-Réanimation, Hôpital Edouard Herriot, Lyon, France
| | - Claude Guérin
- Institut Mondor de Recherches Biomédicales INSERM-UPEC U955 CNRS EMR7000, Créteil, France; Médecine Intensive-Réanimation, Hôpital Edouard Herriot, Lyon, France; and Université de Lyon, Lyon, France
| |
Collapse
|
10
|
Pellegrini M, Sousa MLA, Dubo S, Menga LS, Hsing V, Post M, Brochard LJ. Impact of airway closure and lung collapse on inhaled nitric oxide effect in acute lung injury: an experimental study. Ann Intensive Care 2024; 14:149. [PMID: 39312044 PMCID: PMC11420414 DOI: 10.1186/s13613-024-01378-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2024] [Accepted: 09/10/2024] [Indexed: 09/26/2024] Open
Abstract
BACKGROUND Efficacy of inhaled therapy such as Nitric Oxide (iNO) during mechanical ventilation may depend on airway patency. We hypothesized that airway closure and lung collapse, countered by positive end-expiratory pressure (PEEP), influence iNO efficacy. This could support the role of an adequate PEEP titration for inhalation therapy. The main aim of this study was to assess the effect of iNO with PEEP set above or below the airway opening pressure (AOP) generated by airway closure, on hemodynamics and gas exchange in swine models of acute respiratory distress syndrome. Fourteen pigs randomly underwent either bilateral or asymmetrical two-hit model of lung injury. Airway closure and lung collapse were measured with electrical impedance tomography as well as ventilation/perfusion ratio (V/Q). After AOP detection, the effect of iNO (10ppm) was studied with PEEP set randomly above or below regional AOP. Respiratory mechanics, hemodynamics, and gas-exchange were recorded. RESULTS All pigs presented airway closure (AOP > 0.5cmH2O) after injury. In bilateral injury, iNO was associated with an improved mean pulmonary pressure from 49 ± 8 to 42 ± 7mmHg; (p = 0.003), and ventilation/perfusion matching, caused by a reduction in pixels with low V/Q and shunt from 16%[IQR:13-19] to 9%[IQR:4-12] (p = 0.03) only at PEEP set above AOP. iNO had no effect on hemodynamics or gas exchange for PEEP below AOP (low V/Q 25%[IQR:16-30] to 23%[IQR:14-27]; p = 0.68). In asymmetrical injury, iNO improved pulmonary hemodynamics and ventilation/perfusion matching independently from the PEEP set. iNO was associated with improved oxygenation in all cases. CONCLUSIONS In an animal model of bilateral lung injury, PEEP level relative to AOP markedly influences iNO efficacy on pulmonary hemodynamics and ventilation/perfusion match, independently of oxygenation.
Collapse
Affiliation(s)
- Mariangela Pellegrini
- Anesthesiology and Intensive Care Medicine, Uppsala University Hospital, Uppsala, Sweden.
- Hedenstierna Laboratory, Department of Surgical Sciences, Uppsala University Hospital, Akademiska sjukhuset, ing 40 2 tr. 751 85, Uppsala, Sweden.
| | - Mayson L A Sousa
- Keenan Centre for Biomedical Research, Critical Care Department, St. Michael's Hospital, Unity Health Toronto, Toronto, Canada
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada
- Translational Medicine Program, Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, Toronto, Canada
| | - Sebastian Dubo
- Keenan Centre for Biomedical Research, Critical Care Department, St. Michael's Hospital, Unity Health Toronto, Toronto, Canada
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada
- Translational Medicine Program, Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, Toronto, Canada
- Department of Physiotherapy, Universidad de Concepción, Concepción, Chile
| | - Luca S Menga
- Keenan Centre for Biomedical Research, Critical Care Department, St. Michael's Hospital, Unity Health Toronto, Toronto, Canada
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada
- Translational Medicine Program, Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, Toronto, Canada
| | - Vanessa Hsing
- Translational Medicine Program, Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, Toronto, Canada
| | - Martin Post
- Translational Medicine Program, Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, Toronto, Canada
- Department of Physiology, University of Toronto, Toronto, Canada
| | - Laurent J Brochard
- Keenan Centre for Biomedical Research, Critical Care Department, St. Michael's Hospital, Unity Health Toronto, Toronto, Canada
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada
| |
Collapse
|
11
|
Chen R, Lovas A, Bakos P, Molnár T, Hawchar F, Benyó B, Zhao Z, Chase JG, Rupitsch SJ, Moeller K. Detection of spontaneous breathing during an apnea test in a patient with suspected brain death using electrical impedance tomography: a case report. BMC Pulm Med 2024; 24:454. [PMID: 39285376 PMCID: PMC11406830 DOI: 10.1186/s12890-024-03283-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2024] [Accepted: 09/10/2024] [Indexed: 09/19/2024] Open
Abstract
INTRODUCTION The apnea test (AT) is a crucial procedure in determining brain death (BD), with detection of spontaneous breathing efforts serving as a key criterion. Numerous national statutes mandate complete disconnection of the patient from the ventilator during the procedure to open the airway directly to the atmosphere. These regulations mandate visual observation as an exclusive option for detecting breathing efforts. However, reliance on visual observation alone can pose challenges in identifying subtle respiratory movements. CASE PRESENTATION This case report presents a 55-year-old morbidly obese male patient with suspected BD due to cerebral hemorrhage undergoing an AT. The AT was performed with continuous electrical impedance tomography (EIT) monitoring. Upon detection of spontaneous breathing movements by both visual observation and EIT, the AT was aborted, and the patient was reconnected to the ventilator. EIT indicated a shift in ventilation distribution from the ventral to the dorsal regions, indicating the presence of spontaneous breathing efforts. EIT results also suggested the patient experienced a slow but transient initial recovery phase, likely due to atelectasis induced by morbid obesity, before returning to a steady state of ventilatory support. CONCLUSION The findings suggest EIT could enhance the sensitivity and accuracy of detecting spontaneous breathing efforts, providing additional insights into the respiratory status of patients during the AT.
Collapse
Affiliation(s)
- Rongqing Chen
- Institute of Technical Medicine, Hochschule Furtwangen, Jakob-Kienzle-Str. 17, Villingen-Schwenningen, 78054, Germany.
- Department of Microsystems Engineering (IMTEK), Faculty of Engineering, University of Freiburg, Georges-Köhler-Allee 101, Freiburg, 79110, Germany.
| | - András Lovas
- Department of Anaesthesiology and Intensive Therapy, Kiskunhalas Semmelweis Hospital, Teaching Hospital of the University of Szeged, Dr. Monszpart László u. 1, Kiskunhalas, 6400, Hungary
| | - Péter Bakos
- Department of Anesthesiology and Intensive Therapy, Csolnoky Ferenc Hospital, Kórház u. 1, Veszprém, 8200, Hungary
- Department of Cardiology, State Hospital for Cardiology, Gyógy tér 2, Balatonfüred, 8230, Hungary
| | - Tamás Molnár
- Department of Anesthesiology and Intensive Therapy, University of Szeged, Semmelweis u. 6, Szeged, 6725, Hungary
| | - Fatime Hawchar
- Department of Anesthesiology and Intensive Therapy, Budapesti Dr. Manninger Jenő Traumatology Center, Fiumei út 17, Budapest, 1080, Hungary
| | - Balázs Benyó
- Department of Control Engineering and Information Technology, Faculty of Electrical Engineering and Information Technology, Budapest University of Technology and Economics, Muegyetem rkp. 3, Budapest, 1111, Hungary
| | - Zhanqi Zhao
- Institute of Technical Medicine, Hochschule Furtwangen, Jakob-Kienzle-Str. 17, Villingen-Schwenningen, 78054, Germany
| | - J Geoffrey Chase
- Department of Mechanical Engineering, University of Canterbury, 69 Creyke Road, Christchurch, 8041, New Zealand
| | - Stefan J Rupitsch
- Department of Microsystems Engineering (IMTEK), Faculty of Engineering, University of Freiburg, Georges-Köhler-Allee 101, Freiburg, 79110, Germany
| | - Knut Moeller
- Institute of Technical Medicine, Hochschule Furtwangen, Jakob-Kienzle-Str. 17, Villingen-Schwenningen, 78054, Germany
| |
Collapse
|
12
|
Tingay DG, Fatmous M, Kenna K, Chapman J, Douglas E, Sett A, Poh QH, Dahm SI, Quach TK, Sourial M, Fang H, Greening DW, Pereira-Fantini PM. Speed of lung inflation at birth influences the initiation of lung injury in preterm lambs. JCI Insight 2024; 9:e181228. [PMID: 39106107 PMCID: PMC11457856 DOI: 10.1172/jci.insight.181228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2024] [Accepted: 07/31/2024] [Indexed: 08/09/2024] Open
Abstract
Gas flow is fundamental for driving tidal ventilation and, thus, the speed of lung motion, but current bias flow settings to support the preterm lung after birth do not have an evidence base. We aimed to determine the role of gas bias flow rates to generate positive pressure ventilation in initiating early lung injury pathways in the preterm lamb. Using slower speeds to inflate the lung during tidal ventilation (gas flow rates 4-6 L/min) did not affect lung mechanics, mechanical power, or gas exchange compared with those currently used in clinical practice (8-10 L/min). Speed of pressure and volume change during inflation were faster with higher flow rates. Lower flow rates resulted in less bronchoalveolar fluid protein, better lung morphology, and fewer detached epithelial cells. Overall, relative to unventilated fetal controls, there was greater protein change using 8-10 L/min, which was associated with enrichment of acute inflammatory and innate responses. Slowing the speed of lung motion by supporting the preterm lung from birth with lower flow rates than in current clinical use resulted in less lung injury without compromising tidal ventilation or gas exchange.
Collapse
Affiliation(s)
- David G. Tingay
- Neonatal Research, Murdoch Children’s Research Institute, Parkville, Australia
- Department of Paediatrics, University of Melbourne, Melbourne, Australia
| | - Monique Fatmous
- Neonatal Research, Murdoch Children’s Research Institute, Parkville, Australia
| | - Kelly Kenna
- Neonatal Research, Murdoch Children’s Research Institute, Parkville, Australia
| | - Jack Chapman
- Neonatal Research, Murdoch Children’s Research Institute, Parkville, Australia
- Department of Paediatrics, University of Melbourne, Melbourne, Australia
| | - Ellen Douglas
- Neonatal Research, Murdoch Children’s Research Institute, Parkville, Australia
| | - Arun Sett
- Neonatal Research, Murdoch Children’s Research Institute, Parkville, Australia
- Newborn Services, Joan Kirner Women’s and Children’s, Sunshine Hospital, Western Health, St Albans, Australia
- Department of Obstetrics and Gynaecology, University of Melbourne, Melbourne, Australia
| | - Qi Hui Poh
- Neonatal Research, Murdoch Children’s Research Institute, Parkville, Australia
| | - Sophia I. Dahm
- Neonatal Research, Murdoch Children’s Research Institute, Parkville, Australia
| | - Tuyen Kim Quach
- Neonatal Research, Murdoch Children’s Research Institute, Parkville, Australia
- Department of Paediatrics, University of Melbourne, Melbourne, Australia
| | - Magdy Sourial
- Neonatal Research, Murdoch Children’s Research Institute, Parkville, Australia
- Translational Research Unit, Murdoch Children’s Research Institute, Parkville, Australia
| | - Haoyun Fang
- Molecular Proteomics, Baker Heart and Diabetes Institute, Melbourne, Australia
- Baker Department of Cardiometabolic Health, The University of Melbourne, Melbourne, Australia
| | - David W. Greening
- Molecular Proteomics, Baker Heart and Diabetes Institute, Melbourne, Australia
- Baker Department of Cardiometabolic Health, The University of Melbourne, Melbourne, Australia
- Baker Department of Cardiovascular Research, Translation and Implementation, La Trobe University, Melbourne, Australia
| | - Prue M. Pereira-Fantini
- Neonatal Research, Murdoch Children’s Research Institute, Parkville, Australia
- Department of Paediatrics, University of Melbourne, Melbourne, Australia
| |
Collapse
|
13
|
Lin Y, Chu J, Qiao W, Yu C, Gao C. Pulmonary benign metastasizing leiomyoma presenting as acute hypoxemic respiratory failure: a case report. BMC Pulm Med 2024; 24:376. [PMID: 39090648 PMCID: PMC11295507 DOI: 10.1186/s12890-024-03189-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Accepted: 07/29/2024] [Indexed: 08/04/2024] Open
Abstract
Pulmonary benign metastasizing leiomyoma is an uncommon condition, predominantly affecting women of childbearing age with a history of uterine smooth muscle tumors and uterine leiomyoma surgery for uterine leiomyoma. The progression of PBML is often unpredictable and depends on the extent of lung involvement. Generally, most patients remain asymptomatic, but a minority may experience coughing, wheezing, or shortness of breath, which are frequently misdiagnosed as pneumonia. consequently, this presents significant challenges in both treatment and nursing care before diagnosis. This paper reports the case of a 35-year-old woman primarily diagnosed with acute hypoxic respiratory failure who was transferred from the emergency room to the intensive care unit. The initial computed tomography scan of the patient's lungs indicated diffuse interstitial pneumonia, but the sequencing of the alveolar lavage fluid pathogen macro did not detect any bacteria, fungi, or viruses. Moreover, the patient remained in a persistent hypoxic state before the definitive diagnosis. Therefore, our focus was on maintaining the airway patency of the patient, using prone ventilation, inhaling nitric oxide, monitoring electrical impedance tomography, and preventing ventilator-associated pneumonia to improve oxygenation, while awaiting immunohistochemical staining of the patient's biopsied lung tissue. This would help us clarify the diagnosis and treat it based on etiology. After meticulous treatment and nursing care, the patient was weaned off the ventilator after 26 days and transferred to the respiratory ward after 40 days. This case study may serve as a reference for clinical practice and assist patients suffering from PBML.
Collapse
Affiliation(s)
- Yan Lin
- Department of General Intensive Care Unit, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Junqing Chu
- Department of General Intensive Care Unit, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Wenbo Qiao
- Department of General Intensive Care Unit, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Chao Yu
- Department of Nursing, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Chunhua Gao
- Department of Nursing, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
| |
Collapse
|
14
|
Rutkove SB, McIlduff CE, Stommel E, Levy S, Smith C, Gutierrez H, Verga S, Samaan S, Yator C, Nanda A, Pastel L, Doussan A, Phipps K, Murphy E, Halter R. Assessing pulmonary function in ALS using electrical impedance tomography. Amyotroph Lateral Scler Frontotemporal Degener 2024; 25:581-588. [PMID: 38576194 PMCID: PMC11269030 DOI: 10.1080/21678421.2024.2334075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Revised: 03/14/2024] [Accepted: 03/18/2024] [Indexed: 04/06/2024]
Abstract
OBJECTIVE We sought to determine whether thoracic electrical impedance tomography (EIT) could characterize pulmonary function in amyotrophic lateral sclerosis (ALS) patients, including those with facial weakness. Thoracic EIT is a noninvasive, technology in which a multi-electrode belt is placed across the chest, producing real-time impedance imaging of the chest during breathing. METHODS We enrolled 32 ALS patients and 32 age- and sex-matched healthy controls (HCs) without underlying lung disease. All participants had EIT measurements performed simultaneously with standard pulmonary function tests (PFTs), including slow and forced vital capacity (SVC and FVC) in upright and supine positions and maximal inspiratory and expiratory pressures (MIPs and MEPs, respectively). Intraclass correlation coefficients (ICCs) were calculated to assess the immediate reproducibility of EIT measurements and Pearson's correlations were used to explore the relationships between EIT and PFT values. RESULTS Data from 30 ALS patients and 27 HCs were analyzed. Immediate upright SVC reproducibility was very high (ICC 0.98). Correlations were generally strongest between EIT and spirometry measures, with R values ranging from 0.64 to 0.82 (p < 0.001) in the ALS cohort. There were less robust correlations between EIT values and both MIPs and MEPs in the ALS patients, with R values ranging from 0.33 to 0.44. There was no significant difference for patients with and without facial weakness. There were no reported adverse events. CONCLUSION EIT-based pulmonary measures hold the promise of providing an alternative approach for lung function assessment in ALS patients. Based on these early results, further development and study of this technology are warranted.
Collapse
Affiliation(s)
- Seward B. Rutkove
- Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Courtney E. McIlduff
- Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Elijah Stommel
- Department of Neurology, Dartmouth-Hitchcock Medical Center, Lebanon, NH, USA
| | - Sean Levy
- Department of Medicine, Division of Pulmonary and Critical Care, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Christy Smith
- Department of Medicine, Division of Pulmonary and Critical Care, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Hilda Gutierrez
- Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Sarah Verga
- Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Soleil Samaan
- Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Chebet Yator
- Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Ajitesh Nanda
- Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Lisa Pastel
- Department of Neurology, Dartmouth-Hitchcock Medical Center, Lebanon, NH, USA
| | - Allaire Doussan
- Thayer School of Engineering, Dartmouth College, Hanover, NH, USA
| | - Kathy Phipps
- Thayer School of Engineering, Dartmouth College, Hanover, NH, USA
| | - Ethan Murphy
- Thayer School of Engineering, Dartmouth College, Hanover, NH, USA
| | - Ryan Halter
- Thayer School of Engineering, Dartmouth College, Hanover, NH, USA
| |
Collapse
|
15
|
Batey N, Henry C, Garg S, Wagner M, Malhotra A, Valstar M, Smith T, Sharkey D. The newborn delivery room of tomorrow: emerging and future technologies. Pediatr Res 2024; 96:586-594. [PMID: 35241791 PMCID: PMC11499259 DOI: 10.1038/s41390-022-01988-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 01/10/2022] [Accepted: 02/01/2022] [Indexed: 11/08/2022]
Abstract
Advances in neonatal care have resulted in improved outcomes for high-risk newborns with technologies playing a significant part although many were developed for the neonatal intensive care unit. The care provided in the delivery room (DR) during the first few minutes of life can impact short- and long-term neonatal outcomes. Increasingly, technologies have a critical role to play in the DR particularly with monitoring and information provision. However, the DR is a unique environment and has major challenges around the period of foetal to neonatal transition that need to be overcome when developing new technologies. This review focuses on current DR technologies as well as those just emerging and further over the horizon. We identify what key opinion leaders in DR care think of current technologies, what the important DR measures are to them, and which technologies might be useful in the future. We link these with key technologies including respiratory function monitors, electoral impedance tomography, videolaryngoscopy, augmented reality, video recording, eye tracking, artificial intelligence, and contactless monitoring. Encouraging funders and industry to address the unique technological challenges of newborn care in the DR will allow the continued improvement of outcomes of high-risk infants from the moment of birth. IMPACT: Technological advances for newborn delivery room care require consideration of the unique environment, the variable patient characteristics, and disease states, as well as human factor challenges. Neonatology as a speciality has embraced technology, allowing its rapid progression and improved outcomes for infants, although innovation in the delivery room often lags behind that in the intensive care unit. Investing in new and emerging technologies can support healthcare providers when optimising care and could improve training, safety, and neonatal outcomes.
Collapse
Affiliation(s)
- Natalie Batey
- Nottingham Neonatal Service, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Caroline Henry
- Nottingham Neonatal Service, Nottingham University Hospitals NHS Trust, Nottingham, UK
- Centre for Perinatal Research, School of Medicine, University of Nottingham, Nottingham, UK
| | - Shalabh Garg
- Department of Neonatal Medicine, James Cook University Hospital, Middlesbrough, UK
| | - Michael Wagner
- Division of Neonatology, Pediatric Intensive Care and Neuropediatrics, Department of Pediatrics, Comprehensive Center for Pediatrics, Medical University of Vienna, Vienna, Austria
| | - Atul Malhotra
- Monash Newborn, Monash Children's Hospital and Department of Paediatrics, Monash University, Melbourne, Australia
| | - Michel Valstar
- School of Computer Science, University of Nottingham, Nottingham, UK
| | - Thomas Smith
- School of Computer Science, University of Nottingham, Nottingham, UK
| | - Don Sharkey
- Nottingham Neonatal Service, Nottingham University Hospitals NHS Trust, Nottingham, UK.
- Centre for Perinatal Research, School of Medicine, University of Nottingham, Nottingham, UK.
| |
Collapse
|
16
|
Lee JH, Kang P, Park JB, Ji SH, Jang YE, Kim EH, Kim JT, Kim HS. Determination of optimal positive end-expiratory pressure using electrical impedance tomography in infants under general anesthesia: Comparison between supine and prone positions. Paediatr Anaesth 2024; 34:758-767. [PMID: 38693633 DOI: 10.1111/pan.14914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 04/04/2024] [Accepted: 04/17/2024] [Indexed: 05/03/2024]
Abstract
AIMS This study determined the optimal positive end-expiratory pressure levels in infants in supine and prone positions under general anesthesia using electrical impedance tomography (EIT). METHODS This prospective observational single-centre study included infants scheduled for surgery in the prone position. An electrical impedance tomography sensor was applied after inducing general anesthesia. The optimal positive end-expiratory pressure in the supine position was determined in a decremental trial based on EIT and compliance. Subsequently, the patient's position was changed to prone. Electrical impedance tomography parameters, including global inhomogeneity index, regional ventilation delay, opening pressure, the centre of ventilation, and pendelluft volume, were continuously obtained up to 1 h after prone positioning. The optimal positive end-expiratory pressure in the prone position was similarly determined. RESULTS Data from 30 infants were analyzed. The mean value of electrical impedance tomography-based optimal positive end-expiratory pressure in the prone position was significantly higher than that in the supine position [10.9 (1.6) cmH2O and 6.1 (0.9) cmH2O, respectively (p < .001)]. Significant differences were observed between electrical impedance tomography- and compliance-based optimal positive end-expiratory pressure. Peak and mean airway, plateau, and driving pressures increased 1 h after prone positioning compared with those in the supine position. In addition, the centre of ventilation for balance in ventilation between the ventral and dorsal regions improved. CONCLUSION The prone position required higher positive end-expiratory pressure than the supine position in mechanically ventilated infants under general anesthesia. EIT is a promising tool to find the optimal positive end-expiratory pressure, which needs to be individualized.
Collapse
Affiliation(s)
- Ji-Hyun Lee
- Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, South Korea
| | - Pyoyoon Kang
- Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, South Korea
| | - Jung-Bin Park
- Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, South Korea
| | - Sang-Hwan Ji
- Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, South Korea
| | - Young-Eun Jang
- Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, South Korea
| | - Eun-Hee Kim
- Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, South Korea
| | - Jin-Tae Kim
- Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, South Korea
| | - Hee-Soo Kim
- Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, South Korea
| |
Collapse
|
17
|
Sarkar S, Yalla B, Khanna P, Baishya M. Is EIT-guided positive end-expiratory pressure titration for optimizing PEEP in ARDS the white elephant in the room? A systematic review with meta-analysis and trial sequential analysis. J Clin Monit Comput 2024; 38:873-883. [PMID: 38619718 DOI: 10.1007/s10877-024-01158-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2024] [Accepted: 03/23/2024] [Indexed: 04/16/2024]
Abstract
Electrical Impedance Tomography (EIT) is a novel real-time lung imaging technology for personalized ventilation adjustments, indicating promising results in animals and humans. The present study aimed to assess its clinical utility for improved ventilation and oxygenation compared to traditional protocols. Comprehensive electronic database screening was done until 30th November, 2023. Randomized controlled trials, controlled clinical trials, comparative cohort studies, and assessments of EIT-guided PEEP titration and conventional methods in adult ARDS patients regarding outcome, ventilatory parameters, and P/F ratio were included. Our search retrieved five controlled cohort studies and two RCTs with 515 patients and overall reduced risk of mortality [RR = 0.68; 95% CI: 0.49 to 0.95; I2 = 0%], better dynamic compliance [MD = 3.46; 95% CI: 1.59 to 5.34; I2 = 0%] with no significant difference in PaO2/FiO2 ratio [MD = 6.5; 95%CI -13.86 to 26.76; I2 = 74%]. The required information size except PaO2/FiO2 was achieved for a power of 95% based on the 50% reduction in risk of mortality, 10% improved compliance as the cumulative Z-score of the said outcomes crossed the alpha spending boundary and did not dip below the inner wedge of futility. EIT-guided individualized PEEP titration is a novel modality; further well-designed studies are needed to substantiate its utility.
Collapse
Affiliation(s)
- Soumya Sarkar
- Department of Anaesthesiology, AIIMS, Kalyani, India
| | - Bharat Yalla
- Department of Anaesthesia, Pain Medicine & Critical Care, AIIMS, Ansari Nagar, New Delhi, 110029, India
| | - Puneet Khanna
- Department of Anaesthesia, Pain Medicine & Critical Care, AIIMS, Ansari Nagar, New Delhi, 110029, India.
| | - Madhurjya Baishya
- Department of Anaesthesia, Pain Medicine & Critical Care, AIIMS, Ansari Nagar, New Delhi, 110029, India
| |
Collapse
|
18
|
Hülkenberg AC, Ngo C, Lau R, Leonhardt S. Separation of ventilation and perfusion of electrical impedance tomography image streams using multi-dimensional ensemble empirical mode decomposition. Physiol Meas 2024; 45:075008. [PMID: 38925138 DOI: 10.1088/1361-6579/ad5c39] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Accepted: 06/26/2024] [Indexed: 06/28/2024]
Abstract
Objective.In the future, thoracic electrical impedance tomography (EIT) monitoring may include continuous and simultaneous tracking of both breathing and heart activity. However, an effective way to decompose an EIT image stream into physiological processes as ventilation-related and cardiac-related signals is missing.Approach.This study analyses the potential ofMulti-dimensional Ensemble Empirical Mode Decompositionby application of theComplete Ensemble Empirical Mode Decomposition with Adaptive Noiseand a novel frequency-based combination criterion for detrending, denoising and source separation of EIT image streams, collected from nine healthy male test subjects with similar age and constitution.Main results.In this paper, a novel approach to estimate the lung, the heart and the perfused regions of an EIT image is proposed, which is based on theRoot Mean Square Errorbetween the index of maximal respiratory and cardiac variation to their surroundings. The summation of the indexes of the respective regions reveals physiologically meaningful time signals, separated into the physiological bandwidths of ventilation and heart activity at rest. Moreover, the respective regions were compared with the relative thorax movement and photoplethysmogram (PPG) signal. In linear regression analysis and in the Bland-Altman plot, the beat-to-beat time course of both the ventilation-related signal and the cardiac-related signal showed a high similarity with the respective reference signal.Significance.Analysis of the data reveals a fair separation of ventilatory and cardiac activity realizing the aimed source separation, with optional detrending and denoising. For all performed analyses, a feasible correlation of 0.587 to 0.905 was found between the cardiac-related signal and the PPG signal.
Collapse
Affiliation(s)
- Alfred Christian Hülkenberg
- Chair for Medical Information Technology, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstr. 20, D-52074 Aachen, Germany
| | - Chuong Ngo
- Chair for Medical Information Technology, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstr. 20, D-52074 Aachen, Germany
| | - Robert Lau
- Chair for Medical Information Technology, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstr. 20, D-52074 Aachen, Germany
| | - Steffen Leonhardt
- Chair for Medical Information Technology, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstr. 20, D-52074 Aachen, Germany
| |
Collapse
|
19
|
Lena E, Comuzzi L, Ajčević M, Tarchini M, Moro E, Baso B, Dal Zilio G, Palmisano S, Roman Pognuz E, Fernández R, Lucangelo U. Lung Volume and Ventilation Distribution After Bariatric Surgery: High-Flow Nasal Cannula Versus CPAP. Respir Care 2024; 69:990-998. [PMID: 38744475 PMCID: PMC11298223 DOI: 10.4187/respcare.11356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
Abstract
BACKGROUND Patients with obesity are at increased risk of postoperative pulmonary complications. CPAP has been used successfully to prevent and treat acute respiratory failure, but in many clinical scenarios, high-flow nasal cannula (HFNC) therapy is emerging as a possible alternative. We aimed to compare HFNC and CPAP in a sequential study measuring their effects on gas exchange, lung volumes, and gas distribution within the lungs measured through electrical impedance tomography (EIT). METHODS We enrolled 15 subjects undergoing laparoscopic bariatric surgery. Postoperatively they underwent the following oxygen therapy protocol (10 min/step): baseline air-entrainment mask, HFNC at increasing (40, 60, 80, and 100 L/min) and decreasing flows (80, 60, and 40 L/min), washout air-entrainment mask and CPAP (10 cm H2O). Primary outcome was the change in end-expiratory lung impedance (ΔEELI) measured by EIT data processing. Secondary outcomes were changes of global inhomogeneity (GI) index and tidal impedance variation (TIV) measured by EIT, arterial oxygenation, carbon dioxide content, pH, respiratory frequency, and subject's comfort. RESULTS Thirteen subjects completed the study. Compared to baseline, ΔEELI was higher during 10 cm H2O CPAP (P = .001) and HFNC 100 L/min (P = .02), as well as during decreasing flows HFNC 80, 60, and 40 L/min (P = .008, .004, and .02, respectively). GI index was lower during HFNC 100 compared to HFNC 60increasing (P = .044), HFNC 60decreasing (P = .02) HFNC 40decreasing (P = .01), and during 10 cm H2O CPAP compared to washout period (P = .01) and HFNC 40decreasing (P = .03). TIV was higher during 10 cm H2O CPAP compared to baseline (P = .008). Compared to baseline, breathing frequency was lower at HFNC 60increasing, HFNC 100, and HFNC 80decreasing (P = .01, .02, and .03, respectively). No differences were detected regarding arterial oxygenation, carbon dioxide content, pH, and subject's comfort. CONCLUSIONS HFNC at a flow of 100 L/min induced postoperative pulmonary recruitment in bariatric subjects, with no significant differences compared to 10 cm H2O CPAP in terms of lung recruitment and ventilation distribution.
Collapse
Affiliation(s)
- Enrico Lena
- Department of Anesthesia and Intensive Care, Cattinara Hospital, ASUGI, Trieste, Italy
| | - Lucia Comuzzi
- Department of Anesthesia and Intensive Care, Cattinara Hospital, ASUGI, Trieste, Italy
| | - Milos Ajčević
- Department of Engineering and Architecture, University of Trieste, Trieste, Italy
| | - Martina Tarchini
- Department of Anesthesia and Intensive Care, Cattinara Hospital, ASUGI, Trieste, Italy
| | - Edoardo Moro
- Department of Anesthesia and Intensive Care, Cattinara Hospital, ASUGI, Trieste, Italy
| | - Beatrice Baso
- Department of Anesthesia and Intensive Care, Cattinara Hospital, ASUGI, Trieste, Italy
| | - Giorgia Dal Zilio
- Department of Anesthesia and Intensive Care, Cattinara Hospital, ASUGI, Trieste, Italy
| | - Silvia Palmisano
- Department of Medical, Surgical and Health Sciences, University of Trieste, Trieste, Italy; and Surgical Clinic Unit, Cattinara Hospital, ASUGI, Trieste, Italy
| | - Erik Roman Pognuz
- Department of Anesthesia and Intensive Care, Cattinara Hospital, ASUGI, Trieste, Italy
| | - Rafael Fernández
- Intensive Care Unit, Althaia Xarxa Assistencial Universitària de Manresa, Manresa, CIBERES, Spain
| | - Umberto Lucangelo
- Department of Anesthesia and Intensive Care, Cattinara Hospital, ASUGI, Trieste, Italy
| |
Collapse
|
20
|
Kaczka DW. Imaging the Lung in ARDS: A Primer. Respir Care 2024; 69:1011-1024. [PMID: 39048146 PMCID: PMC11298232 DOI: 10.4187/respcare.12061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/27/2024]
Abstract
Despite periodic changes in the clinical definition of ARDS, imaging of the lung remains a central component of its diagnostic identification. Several imaging modalities are available to the clinician to establish a diagnosis of the syndrome, monitor its clinical course, or assess the impact of treatment and management strategies. Each imaging modality provides unique insight into ARDS from structural and/or functional perspectives. This review will highlight several methods for lung imaging in ARDS, emphasizing basic operational and physical principles for the respiratory therapist. Advantages and disadvantages of each modality will be discussed in the context of their utility for clinical management and decision-making.
Collapse
Affiliation(s)
- David W Kaczka
- Department of Anesthesia, Department of Radiology, and Roy J Carver Department of Biomedical Engineering, University of Iowa, Iowa City, Iowa
| |
Collapse
|
21
|
Leali M, Marongiu I, Spinelli E, Chiavieri V, Perez J, Panigada M, Grasselli G, Mauri T. Absolute values of regional ventilation-perfusion mismatch in patients with ARDS monitored by electrical impedance tomography and the role of dead space and shunt compensation. Crit Care 2024; 28:241. [PMID: 39010228 PMCID: PMC11251389 DOI: 10.1186/s13054-024-05033-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Accepted: 07/11/2024] [Indexed: 07/17/2024] Open
Abstract
BACKGROUND Assessment of regional ventilation/perfusion (V'/Q) mismatch using electrical impedance tomography (EIT) represents a promising advancement for personalized management of the acute respiratory distress syndrome (ARDS). However, accuracy is still hindered by the need for invasive monitoring to calibrate ventilation and perfusion. Here, we propose a non-invasive correction that uses only EIT data and characterized patients with more pronounced compensation of V'/Q mismatch. METHODS We enrolled twenty-one ARDS patients on controlled mechanical ventilation. Cardiac output was measured invasively, and ventilation and perfusion were assessed by EIT. Relative V'/Q maps by EIT were calibrated to absolute values using the minute ventilation to invasive cardiac output (MV/CO) ratio (V'/Q-ABS), left unadjusted (V'/Q-REL), or corrected by MV/CO ratio derived from EIT data (V'/Q-CORR). The ratio between ventilation to dependent regions and perfusion reaching shunted units ( V D ' /QSHUNT) was calculated as an index of more effective hypoxic pulmonary vasoconstriction. The ratio between perfusion to non-dependent regions and ventilation to dead space units (QND/ V DS ' ) was calculated as an index of hypocapnic pneumoconstriction. RESULTS Our calibration factor correlated with invasive MV/CO (r = 0.65, p < 0.001), showed good accuracy and no apparent bias. Compared to V'/Q-ABS, V'/Q-REL maps overestimated ventilation (p = 0.013) and perfusion (p = 0.002) to low V'/Q units and underestimated ventilation (p = 0.011) and perfusion (p = 0.008) to high V'/Q units. The heterogeneity of ventilation and perfusion reaching different V'/Q compartments was underestimated. V'/Q-CORR maps eliminated all these differences with V'/Q-ABS (p > 0.05). HigherV D ' / Q SHUNT correlated with higher PaO2/FiO2 (r = 0.49, p = 0.025) and lower shunt fraction (ρ = - 0.59, p = 0.005). HigherQ ND / V DS ' correlated with lower PEEP (ρ = - 0.62, p = 0.003) and plateau pressure (ρ = - 0.59, p = 0.005). Lower values of both indexes were associated with less ventilator-free days (p = 0.05 and p = 0.03, respectively). CONCLUSIONS Regional V'/Q maps calibrated with a non-invasive EIT-only method closely approximate the ones obtained with invasive monitoring. Higher efficiency of shunt compensation improves oxygenation while compensation of dead space is less needed at lower airway pressure. Patients with more effective compensation mechanisms could have better outcomes.
Collapse
Affiliation(s)
- Marco Leali
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| | - Ines Marongiu
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Elena Spinelli
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Valentina Chiavieri
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| | - Joaquin Perez
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Mauro Panigada
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Giacomo Grasselli
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Tommaso Mauri
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
| |
Collapse
|
22
|
Cui Z, Liu X, Qu H, Wang H. Technical Principles and Clinical Applications of Electrical Impedance Tomography in Pulmonary Monitoring. SENSORS (BASEL, SWITZERLAND) 2024; 24:4539. [PMID: 39065936 PMCID: PMC11281055 DOI: 10.3390/s24144539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 06/11/2024] [Accepted: 07/10/2024] [Indexed: 07/28/2024]
Abstract
Pulmonary monitoring is crucial for the diagnosis and management of respiratory conditions, especially after the epidemic of coronavirus disease. Electrical impedance tomography (EIT) is an alternative non-radioactive tomographic imaging tool for monitoring pulmonary conditions. This review proffers the current EIT technical principles and applications on pulmonary monitoring, which gives a comprehensive summary of EIT applied on the chest and encourages its extensive usage to clinical physicians. The technical principles involving EIT instrumentations and image reconstruction algorithms are explained in detail, and the conditional selection is recommended based on clinical application scenarios. For applications, specifically, the monitoring of ventilation/perfusion (V/Q) is one of the most developed EIT applications. The matching correlation of V/Q could indicate many pulmonary diseases, e.g., the acute respiratory distress syndrome, pneumothorax, pulmonary embolism, and pulmonary edema. Several recently emerging applications like lung transplantation are also briefly introduced as supplementary applications that have potential and are about to be developed in the future. In addition, the limitations, disadvantages, and developing trends of EIT are discussed, indicating that EIT will still be in a long-term development stage before large-scale clinical applications.
Collapse
Affiliation(s)
- Ziqiang Cui
- School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China; (X.L.); (H.Q.); (H.W.)
| | | | | | | |
Collapse
|
23
|
Frerichs I, Händel C, Becher T, Schädler D. Sex differences in chest electrical impedance tomography findings. Physiol Meas 2024; 45:075005. [PMID: 38959902 DOI: 10.1088/1361-6579/ad5ef7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Accepted: 07/03/2024] [Indexed: 07/05/2024]
Abstract
Objective.Electrical impedance tomography (EIT) has been used to determine regional lung ventilation distribution in humans for decades, however, the effect of biological sex on the findings has hardly ever been examined. The aim of our study was to determine if the spatial distribution of ventilation assessed by EIT during quiet breathing was influenced by biological sex.Approach.219 adults with no known acute or chronic lung disease were examined in sitting position with the EIT electrodes placed around the lower chest (6th intercostal space). EIT data were recorded at 33 images/s during quiet breathing for 60 s. Regional tidal impedance variation was calculated in all EIT image pixels and the spatial distribution of the values was determined using the established EIT measures of centre of ventilation in ventrodorsal (CoVvd) and right-to-left direction (CoVrl), the dorsal and right fraction of ventilation, and ventilation defect score.Main results.After exclusion of one subject due to insufficient electrode contact, 218 data sets were analysed (120 men, 98 women) (age: 53 ± 18 vs 50 ± 16 yr (p= 0.2607), body mass index: 26.4 ± 4.0 vs 26.4 ± 6.6 kg m-2(p= 0.9158), mean ± SD). Highly significant differences in ventilation distribution were identified between men and women between the right and left chest sides (CoVrl: 47.0 ± 2.9 vs 48.8 ± 3.3% of chest diameter (p< 0.0001), right fraction of ventilation: 0.573 ± 0.067 vs 0.539 ± 0.071 (p= 0.0004)) and less significant in the ventrodorsal direction (CoVvd: 55.6 ± 4.2 vs 54.5 ± 3.6% of chest diameter (p= 0.0364), dorsal fraction of ventilation: 0.650 ± 0.121 vs 0.625 ± 0.104 (p= 0.1155)). Ventilation defect score higher than one was found in 42.5% of men but only in 16.6% of women.Significance.Biological sex needs to be considered when EIT findings acquired in upright subjects in a rather caudal examination plane are interpreted. Sex differences in chest anatomy and thoracoabdominal mechanics may explain the results.
Collapse
Affiliation(s)
- I Frerichs
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - C Händel
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - T Becher
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - D Schädler
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre Schleswig-Holstein, Campus Kiel, Kiel, Germany
| |
Collapse
|
24
|
Raisis A, Mosing M, Sacks M, Hosgood G, Schramel J, Blumer S, Böhm SH. Breath-by-breath assessment of acute pulmonary edema using electrical impedance tomography, spirometry and volumetric capnography in a sheep ( Ovis Aries) model. Front Vet Sci 2024; 11:1402748. [PMID: 39051008 PMCID: PMC11267825 DOI: 10.3389/fvets.2024.1402748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Accepted: 05/24/2024] [Indexed: 07/27/2024] Open
Abstract
Background The bedside diagnosis of acute pulmonary edema is challenging. This study evaluated the breath-by-breath information from electrical impedance tomography (EIT), respiratory mechanics and volumetric capnography (VCap) to assess acute pulmonary edema induced by xylazine administration in anesthetized sheep. Objective To determine the ability and efficiency of each monitoring modality in detecting changes in lung function associated with onset of pulmonary edema. Methods Twenty healthy ewes were anesthetized, positioned in sternal (prone) recumbency and instrumented. Synchronized recordings of EIT, spirometry and VCap were performed for 60 s prior to start of injection, during xylazine injection over 60 s (0-60 s) and continuously for 1 min (60-120 s) after the end of injection. After visual assessment of the recorded mean variables, statistical analysis was performed using a mixed effect model for repeated measures with Bonferroni's correction for multiple comparisons, to determine at which breath after start of injection the variable was significantly different from baseline. A significant change over time was defined as an adjusted p < 0.05. All statistics were performed using GraphPad Prism 0.1.0. Results Electrical impedance tomography showed significant changes from baseline in all but two variables. These changes were observed simultaneously during xylazine injection at 48 s and were consistent with development of edema in dependent lung (decreased end-expiratory lung impedance, ventilation in centro-ventral and ventral lung region) and shift of ventilation into non-dependent lung (decreased non-dependent silent spaces and increased center of ventilation ventral to dorsal and increased ventilation in centro-dorsal and dorsal lung region). All changes in lung mechanics also occurred during injection, including decreased dynamic respiratory system compliance and increased peak expiratory flow, peak inspiratory pressure and airway resistance at 48, 54 and 60 s, respectively. Changes in VCap variables were delayed with all occurring after completion of the injection. Conclusion In this model of pulmonary edema, EIT detected significant and rapid change in all assessed variables of lung function with changes in regional ventilation indicative of pulmonary edema. Volumetric capnography complemented the EIT findings, while respiratory mechanics were not specific to lung edema. Thus, EIT offers the most comprehensive method for pulmonary edema evaluation, including the assessment of ventilation distribution, thereby enhancing diagnostic capabilities.
Collapse
Affiliation(s)
- Anthea Raisis
- School of Veterinary Medicine, Murdoch University, Murdoch, WA, Australia
| | - Martina Mosing
- School of Veterinary Medicine, Murdoch University, Murdoch, WA, Australia
- Anaesthesiology and Perioperative Intensive Care, Department for Companion Animals and Horses, University of Veterinary Medicine Vienna, Vienna, Austria
| | - Muriel Sacks
- Department of Veterinary Anaesthesia and Analgesia, School of Veterinary Medicine, Murdoch University, Perth, WA, Australia
| | - Giselle Hosgood
- School of Veterinary Medicine, Murdoch University, Murdoch, WA, Australia
| | - Johannes Schramel
- Anaesthesiology and Perioperative Intensive Care, Department for Companion Animals and Horses, University of Veterinary Medicine Vienna, Vienna, Austria
| | - Sarah Blumer
- School of Veterinary Medicine, Murdoch University, Murdoch, WA, Australia
| | - Stephan H. Böhm
- Department of Anesthesiology, Intensive Care Medicine and Pain Therapy, Rostock University Medical Centre, Rostock, Germany
| |
Collapse
|
25
|
Torsani V, Cardoso PFG, Borges JB, Gomes S, Moriya HT, Cruz AFD, Santiago RRDS, Nagao CK, Fitipaldi MF, Beraldo MDA, Junior MHV, Mlček M, Pego-Fernandes PM, Amato MBP. First real-time imaging of bronchoscopic lung volume reduction by electrical impedance tomography. Respir Res 2024; 25:264. [PMID: 38965590 PMCID: PMC11225379 DOI: 10.1186/s12931-024-02877-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Accepted: 06/11/2024] [Indexed: 07/06/2024] Open
Abstract
BACKGROUND Bronchoscopic lung volume reduction (BLVR) with one-way endobronchial valves (EBV) has better outcomes when the target lobe has poor collateral ventilation, resulting in complete lobe atelectasis. High-inspired oxygen fraction (FIO2) promotes atelectasis through faster gas absorption after airway occlusion, but its application during BLVR with EBV has been poorly understood. We aimed to investigate the real-time effects of FIO2 on regional lung volumes and regional ventilation/perfusion by electrical impedance tomography (EIT) during BLVR with EBV. METHODS Six piglets were submitted to left lower lobe occlusion by a balloon-catheter and EBV valves with FIO2 0.5 and 1.0. Regional end-expiratory lung impedances (EELI) and regional ventilation/perfusion were monitored. Local pocket pressure measurements were obtained (balloon occlusion method). One animal underwent simultaneous acquisitions of computed tomography (CT) and EIT. Regions-of-interest (ROIs) were right and left hemithoraces. RESULTS Following balloon occlusion, a steep decrease in left ROI-EELI with FIO2 1.0 occurred, 3-fold greater than with 0.5 (p < 0.001). Higher FIO2 also enhanced the final volume reduction (ROI-EELI) achieved by each valve (p < 0.01). CT analysis confirmed the denser atelectasis and greater volume reduction achieved by higher FIO2 (1.0) during balloon occlusion or during valve placement. CT and pocket pressure data agreed well with EIT findings, indicating greater strain redistribution with higher FIO2. CONCLUSIONS EIT demonstrated in real-time a faster and more complete volume reduction in the occluded lung regions under high FIO2 (1.0), as compared to 0.5. Immediate changes in the ventilation and perfusion of ipsilateral non-target lung regions were also detected, providing better estimates of the full impact of each valve in place. TRIAL REGISTRATION Not applicable.
Collapse
Affiliation(s)
- Vinicius Torsani
- Divisao de Pneumologia, Instituto do Coracao, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, Brasil
| | - Paulo Francisco Guerreiro Cardoso
- Division of Thoracic Surgery, Thoracic Surgery Research Laboratory (LIM 61), Instituto do Coracao, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, Brasil
| | - João Batista Borges
- Institute of Physiology, First Faculty of Medicine, Charles University, Albertov 5, Prague, 128 00, Czech Republic.
| | - Susimeire Gomes
- Divisao de Pneumologia, Instituto do Coracao, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, Brasil
| | - Henrique Takachi Moriya
- Biomedical Engineering Laboratory, Escola Politecnica da Universidade de Sao Paulo, Sao Paulo, Brasil
| | - Andrea Fonseca da Cruz
- Biomedical Engineering Laboratory, Escola Politecnica da Universidade de Sao Paulo, Sao Paulo, Brasil
| | | | - Cristopher Kengo Nagao
- Division of Thoracic Surgery, Thoracic Surgery Research Laboratory (LIM 61), Instituto do Coracao, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, Brasil
| | - Mariana Fernandes Fitipaldi
- Division of Thoracic Surgery, Thoracic Surgery Research Laboratory (LIM 61), Instituto do Coracao, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, Brasil
| | - Marcelo do Amaral Beraldo
- Divisao de Pneumologia, Instituto do Coracao, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, Brasil
| | - Marcus Henrique Victor Junior
- Divisao de Pneumologia, Instituto do Coracao, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, Brasil
| | - Mikuláš Mlček
- Institute of Physiology, First Faculty of Medicine, Charles University, Albertov 5, Prague, 128 00, Czech Republic
| | - Paulo Manuel Pego-Fernandes
- Division of Thoracic Surgery, Thoracic Surgery Research Laboratory (LIM 61), Instituto do Coracao, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, Brasil
| | - Marcelo Britto Passos Amato
- Divisao de Pneumologia, Instituto do Coracao, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, Brasil
| |
Collapse
|
26
|
Belting C, Rüegger CM, Waldmann AD, Bassler D, Gaertner VD. Rescue nasopharyngeal tube for preterm infants non-responsive to initial ventilation after birth. Pediatr Res 2024; 96:141-147. [PMID: 38273117 PMCID: PMC11257935 DOI: 10.1038/s41390-024-03033-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Revised: 11/29/2023] [Accepted: 12/29/2023] [Indexed: 01/27/2024]
Abstract
BACKGROUND Physiological changes during the insertion of a rescue nasopharyngeal tube (NPT) after birth are unclear. METHODS Observational study of very preterm infants in the delivery room. Data were extracted at predefined timepoints starting with first facemask placement after birth until 5 min after insertion of NPT. End-expiratory lung impedance (EELI), heart rate (HR) and SpO2/FiO2-ratio were analysed over time. Changes during the same time span of NIPPV via facemask and NIPPV via NPT were compared. RESULTS Overall, 1154 inflations in 15 infants were analysed. After NPT insertion, EELI increased significantly [0.33 AU/kg (0.19-0.57), p < 0.001]. Compared with the mask period, changes in EELI were not significantly larger during the NPT period [median difference (IQR) = 0.14 AU/kg (-0.14-0.53); p = 0.12]. Insertion of the NPT was associated with significant improvement in HR [52 (33-96); p = 0.001] and SpO2/FiO2-ratio [161 (69-169); p < 0.001] not observed during the mask period. CONCLUSIONS In very preterm infants non-responsive to initial facemask ventilation after birth, insertion of an NPT resulted in a considerable increase in EELI. This additional gain in lung volume was associated with an immediate improvement in clinical parameters. The use of a NPT may prevent intubation in selected non-responsive infants. IMPACT After birth, a nasopharyngeal tube may be considered as a rescue airway in newborn infants non-responsive to initial positive pressure ventilation via facemask. Although it is widely used among clinicians, its effect on lung volumes and physiological parameters remains unclear. Insertion of a rescue NPT resulted in a considerable increase in lung volume but this was not significantly larger than during facemask ventilation. However, insertion of a rescue NPT was associated with a significant and clinically important improvement in heart rate and oxygenation. This study highlights the importance of individual strategies in preterm resuscitation and introduces the NPT as a valid option.
Collapse
Affiliation(s)
- Carina Belting
- Newborn Research, Department of Neonatology, University Hospital and University of Zürich, Zürich, Switzerland
- Department of Pediatric Intensive Care and Neonatology, Children's Hospital of Eastern Switzerland, St. Gallen, Switzerland
| | - Christoph M Rüegger
- Newborn Research, Department of Neonatology, University Hospital and University of Zürich, Zürich, Switzerland
| | - Andreas D Waldmann
- Department of Anaesthesiology and Intensive Care Medicine, Rostock University Medical Centre, Rostock, Germany
| | - Dirk Bassler
- Newborn Research, Department of Neonatology, University Hospital and University of Zürich, Zürich, Switzerland
| | - Vincent D Gaertner
- Newborn Research, Department of Neonatology, University Hospital and University of Zürich, Zürich, Switzerland.
- Division of Neonatology, Dr von Hauner Children's Hospital, Ludwig-Maximilians-Universität München, Munich, Germany.
| |
Collapse
|
27
|
Chen H, Huang M, Zhou J, Zhang X, Chen S, Liu C, Zhang K, Li Y, Zhang Y, Huang C. Enhancement of Pulmonary Function and Reduction of Complications Through EIT-Guided Yoga Breathing Exercise After Esophagectomy. Med Sci Monit 2024; 30:e942954. [PMID: 38949992 PMCID: PMC11305053 DOI: 10.12659/msm.942954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Accepted: 05/12/2024] [Indexed: 07/03/2024] Open
Abstract
BACKGROUND This study aimed to investigate the impact of EIT-guided yoga breathing training on postoperative pulmonary complications (PPCs) for esophageal cancer patients. MATERIAL AND METHODS Total of 62 patients underwent radical resections of esophageal cancer. Esophageal cancer patients were randomized to the standard care group, or the intervention group receiving an additional complete breathing exercise under the guidance of EIT in AICU. Following extubation after the esophagectomy, pulmonary functions were evaluated by EIT with center of ventilation (CoV), dependent silent spaces (DSS), and non-dependent silent spaces (NSS). RESULTS Sixty-one older esophageal cancer patients (31 in the Control group and 30 in the EIT group) were included in the final analysis. Forty-four patients experienced pulmonary complications after esophagectomy, 27 (87.1%) in the Control group and 17 (36.7%) in the EIT group (RR, 0.42 (95% CI: 0.26, 0.69). The most common pulmonary complication was pleural effusion, with an incidence of 30% in the EIT group and 74.2% in the Control group, with RR of 0.40 (95% CI: 0.23, 0.73). Time for the first pulmonary complication was significantly longer in the EIT group than in the Control group (hazard ratio, HR, 0.43; 95% CI 0.21 to 0.87; P=0.019). Patients in the EIT group had significantly higher scores in CoV, DSS, and NSS than in the Control group. CONCLUSIONS Guided by EIT, the addition of the postoperative breathing exercise to the standardized care during AICU could further improve pulmonary function, and reduce postoperative pulmonary complications after esophagectomy.
Collapse
Affiliation(s)
- Hong Chen
- Department of Anesthesiology and Perioperative Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
- Key Laboratory of Anesthesiology and Perioperative Medicine of Anhui Higher Education Institutes, Anhui Medical University, Hefei, Anhui, PR China
- Scientific Research and Experiment Center, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
| | - Minli Huang
- Department of Anesthesiology and Perioperative Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
- Key Laboratory of Anesthesiology and Perioperative Medicine of Anhui Higher Education Institutes, Anhui Medical University, Hefei, Anhui, PR China
- Scientific Research and Experiment Center, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
| | - Juan Zhou
- Department of Anesthesiology and Perioperative Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
- Key Laboratory of Anesthesiology and Perioperative Medicine of Anhui Higher Education Institutes, Anhui Medical University, Hefei, Anhui, PR China
- Scientific Research and Experiment Center, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
| | - Xiaoyan Zhang
- Department of Anesthesiology and Perioperative Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
- Key Laboratory of Anesthesiology and Perioperative Medicine of Anhui Higher Education Institutes, Anhui Medical University, Hefei, Anhui, PR China
- Scientific Research and Experiment Center, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
| | - Shan Chen
- Department of Anesthesiology and Perioperative Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
- Key Laboratory of Anesthesiology and Perioperative Medicine of Anhui Higher Education Institutes, Anhui Medical University, Hefei, Anhui, PR China
- Scientific Research and Experiment Center, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
| | - Chengxiang Liu
- Department of Anesthesiology and Perioperative Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
- Key Laboratory of Anesthesiology and Perioperative Medicine of Anhui Higher Education Institutes, Anhui Medical University, Hefei, Anhui, PR China
- Scientific Research and Experiment Center, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
| | - Ke Zhang
- Department of Thoracic Surgery, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
| | - Yun Li
- Department of Anesthesiology and Perioperative Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
- Key Laboratory of Anesthesiology and Perioperative Medicine of Anhui Higher Education Institutes, Anhui Medical University, Hefei, Anhui, PR China
- Scientific Research and Experiment Center, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
| | - Ye Zhang
- Department of Anesthesiology and Perioperative Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
- Key Laboratory of Anesthesiology and Perioperative Medicine of Anhui Higher Education Institutes, Anhui Medical University, Hefei, Anhui, PR China
- Scientific Research and Experiment Center, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
| | - Chunxia Huang
- Department of Anesthesiology and Perioperative Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
- Key Laboratory of Anesthesiology and Perioperative Medicine of Anhui Higher Education Institutes, Anhui Medical University, Hefei, Anhui, PR China
- Scientific Research and Experiment Center, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
| |
Collapse
|
28
|
Rub DM, Loft L, Tingay DG, Hodgson K. Moving past the face mask? Nasopharyngeal tube and aeration during preterm resuscitation. Pediatr Res 2024; 96:23-24. [PMID: 38443519 PMCID: PMC11257943 DOI: 10.1038/s41390-024-03127-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Accepted: 02/10/2024] [Indexed: 03/07/2024]
Affiliation(s)
- David M Rub
- Division of Neonatology, Children's Hospital of Philadelphia, Philadelphia, PA, USA
- Department of Pediatrics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Lucy Loft
- Neonatal Research, Murdoch Children's Research Institute, Melbourne, VIC, Australia
- Neonatal Research, Royal Women's Hospital, Melbourne, VIC, Australia
| | - David G Tingay
- Neonatal Research, Murdoch Children's Research Institute, Melbourne, VIC, Australia.
- Neonatal Research, Royal Women's Hospital, Melbourne, VIC, Australia.
- Department of Paediatrics, University of Melbourne, Melbourne, VIC, Australia.
| | - Kate Hodgson
- Neonatal Research, Murdoch Children's Research Institute, Melbourne, VIC, Australia
- Neonatal Research, Royal Women's Hospital, Melbourne, VIC, Australia
- Department of Obstetrics, Gynaecology and Newborn Health, University of Melbourne, Melbourne, VIC, Australia
| |
Collapse
|
29
|
Liu W, Chi Y, Zhao Y, He H, Long Y, Zhao Z. Occurrence of pendelluft during ventilator weaning with T piece correlated with increased mortality in difficult-to-wean patients. J Intensive Care 2024; 12:23. [PMID: 38915067 PMCID: PMC11194869 DOI: 10.1186/s40560-024-00737-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Accepted: 06/14/2024] [Indexed: 06/26/2024] Open
Abstract
BACKGROUND Difficult-to-wean patients, typically identified as those failing the initial spontaneous breathing trial (SBT), face elevated mortality rates. Pendelluft, frequently observed in patients experiencing SBT failure, can be conveniently detected through bedside monitoring with electrical impedance tomography (EIT). This study aimed to explore the impact of pendelluft during SBT on difficult-to-wean patients. METHODS This retrospective observational study included difficult-to-wean patients undergoing spontaneous T piece breathing, during which EIT data were collected. Pendelluft occurrence was defined when its amplitude exceeded 2.5% of global tidal impedance variation. Physiological parameters during SBT were retrospectively retrieved from the EIT Examination Report Form. Other clinical data including mechanical ventilation duration, length of ICU stay, length of hospital stay, and 28-day mortality were retrieved from patient records in the hospital information system for each subject. RESULTS Pendelluft was observed in 72 (70.4%) of the 108 included patients, with 16 (14.8%) experiencing mortality by day 28. The pendelluft group exhibited significantly higher mortality (19.7% vs. 3.1%, p = 0.035), longer median mechanical ventilation duration [9 (5-15) vs. 7 (5-11) days, p = 0.041] and shorter ventilator-free days at day 28 [18 (4-22) vs. 20 (16-23) days, p = 0.043]. The presence of pendellfut was independently associated with increased mortality at day 28 (OR = 10.50, 95% confidence interval 1.21-90.99, p = 0.033). CONCLUSIONS Pendelluft occurred in 70.4% of difficult-to-wean patients undergoing T piece spontaneous breathing. Pendelluft was associated with worse clinical outcomes, including prolonged mechanical ventilation and increased mortality in this population. Our findings underscore the significance of monitoring pendelluft using EIT during SBT for difficult-to-wean patients.
Collapse
Affiliation(s)
- Wanglin Liu
- State Key Laboratory of Complex Severe and Rare Disease, Department of Critical Care Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, 1 Shuaifuyuan, Dongcheng District, Beijing, China
| | - Yi Chi
- State Key Laboratory of Complex Severe and Rare Disease, Department of Critical Care Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, 1 Shuaifuyuan, Dongcheng District, Beijing, China
| | - Yutong Zhao
- State Key Laboratory of Complex Severe and Rare Disease, Department of Critical Care Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, 1 Shuaifuyuan, Dongcheng District, Beijing, China
- Department of Critical Care Medicine, The First Clinical Medical College of Shanxi Medical University, Taiyuan, China
| | - Huaiwu He
- State Key Laboratory of Complex Severe and Rare Disease, Department of Critical Care Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, 1 Shuaifuyuan, Dongcheng District, Beijing, China.
| | - Yun Long
- State Key Laboratory of Complex Severe and Rare Disease, Department of Critical Care Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, 1 Shuaifuyuan, Dongcheng District, Beijing, China.
| | - Zhanqi Zhao
- State Key Laboratory of Complex Severe and Rare Disease, Department of Critical Care Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, 1 Shuaifuyuan, Dongcheng District, Beijing, China.
- School of Biomedical Engineering, Guangzhou Medical University, No. 1 Xinzao Rd. Panyu District, Guangzhou, China.
- Institute of Technical Medicine, Furtwangen University, VS-Schwenningen, Germany.
| |
Collapse
|
30
|
Cappellini I, Campagnola L, Consales G. Electrical Impedance Tomography, Artificial Intelligence, and Variable Ventilation: Transforming Respiratory Monitoring and Treatment in Critical Care. J Pers Med 2024; 14:677. [PMID: 39063931 PMCID: PMC11277617 DOI: 10.3390/jpm14070677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2024] [Revised: 06/19/2024] [Accepted: 06/21/2024] [Indexed: 07/28/2024] Open
Abstract
BACKGROUND Electrical Impedance Tomography (EIT), combined with variable ventilation strategies and Artificial Intelligence (AI), is poised to revolutionize critical care by transitioning from reactive to predictive approaches. This integration aims to enhance patient outcomes through personalized interventions and real-time monitoring. METHODS this narrative review explores the principles and applications of EIT, variable ventilation, and AI in critical care. EIT impedance sensing creates dynamic images of internal physiology, aiding the management of conditions like Acute Respiratory Distress Syndrome (ARDS). Variable ventilation mimics natural breathing variability to improve lung function and minimize ventilator-induced lung injury. AI enhances EIT through advanced image reconstruction techniques, neural networks, and digital twin technology, offering more accurate diagnostics and tailored therapeutic interventions. CONCLUSIONS the confluence of EIT, variable ventilation, and AI represents a significant advancement in critical care, enabling a predictive, personalized approach. EIT provides real-time insights into lung function, guiding precise ventilation adjustments and therapeutic interventions. AI integration enhances EIT diagnostic capabilities, facilitating the development of personalized treatment plans. This synergy fosters interdisciplinary collaborations and sets the stage for innovative research, ultimately improving patient outcomes and advancing the future of critical care.
Collapse
Affiliation(s)
- Iacopo Cappellini
- Department of Critical Care, Section of Anesthesiology and Critical Care, Azienda USL Toscana Centro, Ospedale Santo Stefano, 59100 Prato, Italy; (L.C.); (G.C.)
| | | | | |
Collapse
|
31
|
Sousa MLA, Katira BH, Bouch S, Hsing V, Engelberts D, Amato MBP, Post M, Brochard LJ. Limiting Overdistention or Collapse When Mechanically Ventilating Injured Lungs: A Randomized Study in a Porcine Model. Am J Respir Crit Care Med 2024; 209:1441-1452. [PMID: 38354065 DOI: 10.1164/rccm.202310-1895oc] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Accepted: 02/14/2024] [Indexed: 02/16/2024] Open
Abstract
Rationale: It is unknown whether preventing overdistention or collapse is more important when titrating positive end-expiratory pressure (PEEP) in acute respiratory distress syndrome (ARDS). Objectives: To compare PEEP targeting minimal overdistention or minimal collapse or using a compromise between collapse and overdistention in a randomized trial and to assess the impact on respiratory mechanics, gas exchange, inflammation, and hemodynamics. Methods: In a porcine model of ARDS, lung collapse and overdistention were estimated using electrical impedance tomography during a decremental PEEP titration. Pigs were randomized to three groups and ventilated for 12 hours: PEEP set at ⩽3% of overdistention (low overdistention), ⩽3% of collapse (low collapse), and the crossing point of collapse and overdistention. Measurements and Main Results: Thirty-six pigs (12 per group) were included. Median (interquartile range) values of PEEP were 7 (6-8), 11 (10-11), and 15 (12-16) cm H2O in the three groups (P < 0.001). With low overdistension, 6 (50%) pigs died, whereas survival was 100% in both other groups. Cause of death was hemodynamic in nature, with high transpulmonary vascular gradient and high epinephrine requirements. Compared with the other groups, pigs surviving with low overdistension had worse respiratory mechanics and gas exchange during the entire protocol. Minimal differences existed between crossing-point and low-collapse animals in physiological parameters, but postmortem alveolar density was more homogeneous in the crossing-point group. Inflammatory markers were not significantly different. Conclusions: PEEP to minimize overdistention resulted in high mortality in an animal model of ARDS. Minimizing collapse or choosing a compromise between collapse and overdistention may result in less lung injury, with potential benefits of the compromise approach.
Collapse
Affiliation(s)
- Mayson L A Sousa
- Keenan Centre for Biomedical Research, Critical Care Department, St. Michael's Hospital, Unity Health Toronto, Toronto, Ontario, Canada
- Interdepartmental Division of Critical Care Medicine and
- Translational Medicine Program, Research Institute, Hospital for Sick Children, Toronto, Ontario, Canada
| | - Bhushan H Katira
- Translational Medicine Program, Research Institute, Hospital for Sick Children, Toronto, Ontario, Canada
- Pediatric Critical Care Medicine, Washington University in St. Louis, St. Louis, Missouri
| | - Sheena Bouch
- Translational Medicine Program, Research Institute, Hospital for Sick Children, Toronto, Ontario, Canada
| | - Vanessa Hsing
- Translational Medicine Program, Research Institute, Hospital for Sick Children, Toronto, Ontario, Canada
| | - Doreen Engelberts
- Translational Medicine Program, Research Institute, Hospital for Sick Children, Toronto, Ontario, Canada
| | - Marcelo B P Amato
- Divisão de Pneumologia, Faculdade de Medicina da Universidade de São Paulo, Sao Paulo, Brazil
- Instituto do Coração - InCor, Hospital das Clinicas, Faculade de Medicina da Universidade de São Paulo, São Paulo, Brazil; and
| | - Martin Post
- Department of Physiology, University of Toronto, Toronto, Ontario, Canada
- Translational Medicine Program, Research Institute, Hospital for Sick Children, Toronto, Ontario, Canada
| | - Laurent J Brochard
- Keenan Centre for Biomedical Research, Critical Care Department, St. Michael's Hospital, Unity Health Toronto, Toronto, Ontario, Canada
- Interdepartmental Division of Critical Care Medicine and
| |
Collapse
|
32
|
Wisse JJ, Flinsenberg MJW, Jonkman AH, Goos TG, Gommers D. Respiratory rate monitoring in ICU patients and healthy volunteers using electrical impedance tomography: a validation study. Physiol Meas 2024; 45:055026. [PMID: 38588677 DOI: 10.1088/1361-6579/ad3c0e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Accepted: 04/08/2024] [Indexed: 04/10/2024]
Abstract
Objective. The respiratory rate (RR) is considered one of the most informative vital signals. A well-validated standard for RR measurement in mechanically ventilated patient is capnography; a noninvasive technique for expiratory CO2measurements. Reliable RR measurements in spontaneously breathing patients remains a challenge as continuous mainstream capnography measurements are not available. This study aimed to assess the accuracy of RR measurement using electrical impedance tomography (EIT) in healthy volunteers and intensive care unit (ICU) patients on mechanical ventilation and spontaneously breathing post-extubation. Comparator methods included RR derived from both capnography and bioimpedance electrocardiogram (ECG) measurements.Approach. Twenty healthy volunteers wore an EIT belt and ECG electrodes while breathing through a capnometer within a 10-40 breaths per minute (BPM) range. Nineteen ICU patients underwent similar measurements during pressure support ventilation and spontaneously breathing after extubation from mechanical ventilation. Stable periods with regular breathing and no artefacts were selected, and agreement between measurement methods was assessed using Bland-Altman analysis for repeated measurements.Main result. Bland-Altman analysis revealed a bias less than 0.2 BPM, with tight limits of agreement (LOA) ±1.5 BPM in healthy volunteers and ventilated ICU patients when comparing EIT to capnography. Spontaneously breathing ICU patients had wider LOA (±2.5 BPM) when comparing EIT to ECG bioimpedance, but gold standard comparison was unavailable. RR measurements were stable for 91% of the time for capnography, 68% for EIT, and 64% of the ECG bioimpedance signals. After extubation, the percentage of stable periods decreased to 48% for EIT signals and to 55% for ECG bioimpedance.Significance. In periods of stable breathing, EIT demonstrated excellent RR measurement accuracy in healthy volunteers and ICU patients. However, stability of both EIT and ECG bioimpedance RR measurements declined in spontaneously breathing patients to approximately 50% of the time.
Collapse
Affiliation(s)
- J J Wisse
- Department of Adult Intensive Care, Erasmus Medical Center, Rotterdam, The Netherlands
- Department of Neonatal and Pediatric Intensive Care, Erasmus Medical Center-Sophia Children's Hospital, Rotterdam, The Netherlands
| | - M J W Flinsenberg
- Department of Adult Intensive Care, Erasmus Medical Center, Rotterdam, The Netherlands
- Department of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Delft, The Netherlands
| | - A H Jonkman
- Department of Adult Intensive Care, Erasmus Medical Center, Rotterdam, The Netherlands
| | - T G Goos
- Department of Neonatal and Pediatric Intensive Care, Erasmus Medical Center-Sophia Children's Hospital, Rotterdam, The Netherlands
- Department of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Delft, The Netherlands
| | - D Gommers
- Department of Adult Intensive Care, Erasmus Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
33
|
Iwata H, Yoshida T, Hoshino T, Aiyama Y, Maezawa T, Hashimoto H, Koyama Y, Yamada T, Fujino Y. Electrical Impedance Tomography-based Ventilation Patterns in Patients after Major Surgery. Am J Respir Crit Care Med 2024; 209:1328-1337. [PMID: 38346178 DOI: 10.1164/rccm.202309-1658oc] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Accepted: 02/12/2024] [Indexed: 06/01/2024] Open
Abstract
Rationale: General anesthesia and mechanical ventilation have negative impacts on the respiratory system, causing heterogeneous distribution of lung aeration, but little is known about the ventilation patterns of postoperative patients and their association with clinical outcomes. Objectives: To clarify the phenotypes of ventilation patterns along a gravitational direction after surgery by using electrical impedance tomography (EIT) and to evaluate their association with postoperative pulmonary complications (PPCs) and other relevant clinical outcomes. Methods: Adult postoperative patients at high risk for PPCs, receiving mechanical ventilation on ICU admission (N = 128), were prospectively enrolled between November 18, 2021 and July 18, 2022. PPCs were prospectively scored until hospital discharge, and their association with phenotypes of ventilation patterns was studied. The secondary outcomes were the times to wean from mechanical ventilation and oxygen use and the length of ICU stay. Measurements and Main Results: Three phenotypes of ventilation patterns were revealed by EIT: phenotype 1 (32% [n = 41], a predominance of ventral ventilation), phenotype 2 (41% [n = 52], homogeneous ventilation), and phenotype 3 (27% [n = 35], a predominance of dorsal ventilation). The median PPC score was higher in phenotype 1 and phenotype 3 than in phenotype 2. The median time to wean from mechanical ventilation was longer in phenotype 1 versus phenotype 2. The median duration of ICU stay was longer in phenotype 1 versus phenotype 2. The median time to wean from oxygen use was longer in phenotype 1 and phenotype 3 than in phenotype 2. Conclusions: Inhomogeneous ventilation patterns revealed by EIT on ICU admission were associated with PPCs, delayed weaning from mechanical ventilation and oxygen use, and a longer ICU stay.
Collapse
Affiliation(s)
- Hirofumi Iwata
- Department of Anesthesiology and Intensive Care Medicine, Osaka University Graduate School of Medicine, Suita, Japan; and
| | - Takeshi Yoshida
- Department of Anesthesiology and Intensive Care Medicine, Osaka University Graduate School of Medicine, Suita, Japan; and
| | - Taiki Hoshino
- Department of Anesthesiology and Intensive Care Medicine, Osaka University Graduate School of Medicine, Suita, Japan; and
| | - Yuki Aiyama
- Department of Anesthesiology and Intensive Care Medicine, Osaka University Graduate School of Medicine, Suita, Japan; and
| | - Takashi Maezawa
- Department of Anesthesiology and Intensive Care Medicine, Osaka University Graduate School of Medicine, Suita, Japan; and
| | - Haruka Hashimoto
- Department of Anesthesiology and Intensive Care Medicine, Osaka University Graduate School of Medicine, Suita, Japan; and
| | - Yukiko Koyama
- Department of Anesthesiology and Intensive Care Medicine, Osaka University Graduate School of Medicine, Suita, Japan; and
| | - Tomomi Yamada
- The Department of Medical Innovation Data Coordinating Center, Osaka University Hospital, Suita, Japan
| | - Yuji Fujino
- Department of Anesthesiology and Intensive Care Medicine, Osaka University Graduate School of Medicine, Suita, Japan; and
| |
Collapse
|
34
|
Cabezudo Ballesteros S, Sanabria Carretero P, Reinoso Barbero F. Review of electrical impedance tomography in the pediatric patient. REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION 2024; 71:479-485. [PMID: 38458492 DOI: 10.1016/j.redare.2024.03.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Accepted: 08/28/2023] [Indexed: 03/10/2024]
Abstract
Electrical impedance tomography (EIT) is a new method of monitoring non-invasive mechanical ventilation, at the bedside and useful in critically ill patients. It allows lung monitoring of ventilation and perfusion, obtaining images that provide information on lung function. It is based on the physical principle of impedanciometry or the body's ability to conduct an electrical current. Various studies have shown its usefulness both in adults and in pediatrics in respiratory distress syndrome, pneumonia and atelectasis in addition to pulmonary thromboembolism and pulmonary hypertension by also providing information on pulmonary perfusion, and may be very useful in perioperative medicine; especially in pediatrics avoiding repetitive imaging tests with ionizing radiation.
Collapse
Affiliation(s)
| | - P Sanabria Carretero
- Servicio de Anestesia y Reanimación, Hospital Universitario La Paz, Madrid, Spain
| | - F Reinoso Barbero
- Servicio de Anestesia y Reanimación, Hospital Universitario La Paz, Madrid, Spain
| |
Collapse
|
35
|
Coudroy R, Lejars A, Rodriguez M, Frat JP, Rault C, Arrivé F, Le Pape S, Thille AW. Physiologic Effects of Reconnection to the Ventilator for 1 Hour Following a Successful Spontaneous Breathing Trial. Chest 2024; 165:1406-1414. [PMID: 38295948 DOI: 10.1016/j.chest.2024.01.038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 01/16/2024] [Accepted: 01/20/2024] [Indexed: 03/03/2024] Open
Abstract
BACKGROUND Reconnection to the ventilator for 1 h following a successful spontaneous breathing trial (SBT) may reduce reintubation rates compared with direct extubation. However, the physiologic mechanisms leading to this effect are unclear. RESEARCH QUESTION Does reconnection to the ventilator for 1 h reverse alveolar derecruitment induced by SBT, and is alveolar derecruitment more pronounced with a T-piece than with pressure-support ventilation (PSV)? STUDY DESIGN AND METHODS This is an ancillary study of a randomized clinical trial comparing SBT performed with a T-piece or with PSV. Alveolar recruitment was assessed by using measurement of end-expiratory lung volume (EELV). RESULTS Of the 25 patients analyzed following successful SBT, 11 underwent SBT with a T-piece and 14 with PSV. At the end of the SBT, EELV decreased by -30% (95% CI, -37 to -23) compared with baseline prior to the SBT. This reduction was greater with a T-piece than with PSV: -43% (95% CI, -51 to -35) vs -20% (95% CI, -26 to -13); P < .001. Following reconnection to the ventilator for 1 h, EELV accounted for 96% (95% CI, 92 to 101) of baseline EELV and did not significantly differ from prior to the SBT (P = .104). Following 10 min of reconnection to the ventilator, EELV wasted at the end of the SBT was completely recovered using PSV (P = .574), whereas it remained lower than prior to the SBT using a T-piece (P = .010). INTERPRETATION Significant alveolar derecruitment was observed at the end of an SBT and was markedly more pronounced with a T-piece than with PSV. Reconnection to the ventilator for 1 h allowed complete recovery of alveolar derecruitment. CLINICAL TRIAL REGISTRATION ClinicalTrials.gov; No.: NCT04227639; URL: www. CLINICALTRIALS gov.
Collapse
Affiliation(s)
- Rémi Coudroy
- CHU de Poitiers, Service de Médecine Intensive Réanimation, Poitiers, France; INSERM CIC 1402, IS-ALIVE Research Group, Université de Poitiers, Poitiers, France.
| | - Alice Lejars
- CHU de Poitiers, Service de Médecine Intensive Réanimation, Poitiers, France
| | - Maeva Rodriguez
- CHU de Poitiers, Service de Médecine Intensive Réanimation, Poitiers, France
| | - Jean-Pierre Frat
- CHU de Poitiers, Service de Médecine Intensive Réanimation, Poitiers, France; INSERM CIC 1402, IS-ALIVE Research Group, Université de Poitiers, Poitiers, France
| | - Christophe Rault
- INSERM CIC 1402, IS-ALIVE Research Group, Université de Poitiers, Poitiers, France; CHU de Poitiers, Service d'Explorations Fonctionnelles, de Physiologie Respiratoire et de l'Exercice, Poitiers, France
| | - François Arrivé
- CHU de Poitiers, Service de Médecine Intensive Réanimation, Poitiers, France
| | - Sylvain Le Pape
- CHU de Poitiers, Service de Médecine Intensive Réanimation, Poitiers, France
| | - Arnaud W Thille
- CHU de Poitiers, Service de Médecine Intensive Réanimation, Poitiers, France; INSERM CIC 1402, IS-ALIVE Research Group, Université de Poitiers, Poitiers, France
| |
Collapse
|
36
|
Bello G, Giammatteo V, Bisanti A, Delle Cese L, Rosà T, Menga LS, Montini L, Michi T, Spinazzola G, De Pascale G, Pennisi MA, Ribeiro De Santis Santiago R, Berra L, Antonelli M, Grieco DL. High vs Low PEEP in Patients With ARDS Exhibiting Intense Inspiratory Effort During Assisted Ventilation: A Randomized Crossover Trial. Chest 2024; 165:1392-1405. [PMID: 38295949 DOI: 10.1016/j.chest.2024.01.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 01/21/2024] [Accepted: 01/23/2024] [Indexed: 02/26/2024] Open
Abstract
BACKGROUND Positive end-expiratory pressure (PEEP) can potentially modulate inspiratory effort (ΔPes), which is the major determinant of self-inflicted lung injury. RESEARCH QUESTION Does high PEEP reduce ΔPes in patients with moderate-to-severe ARDS on assisted ventilation? STUDY DESIGN AND METHODS Sixteen patients with Pao2/Fio2 ≤ 200 mm Hg and ΔPes ≥ 10 cm H2O underwent a randomized sequence of four ventilator settings: PEEP = 5 cm H2O or PEEP = 15 cm H2O + synchronous (pressure support ventilation [PSV]) or asynchronous (pressure-controlled intermittent mandatory ventilation [PC-IMV]) inspiratory assistance. ΔPes and respiratory system, lung, and chest wall mechanics were assessed with esophageal manometry and occlusions. PEEP-induced alveolar recruitment and overinflation, lung dynamic strain, and tidal volume distribution were assessed with electrical impedance tomography. RESULTS ΔPes was not systematically different at high vs low PEEP (pressure support ventilation: median, 20 cm H2O; interquartile range (IQR), 15-24 cm H2O vs median, 15 cm H2O; IQR, 13-23 cm H2O; P = .24; pressure-controlled intermittent mandatory ventilation: median, 20; IQR, 18-23 vs median, 19; IQR, 17-25; P = .67, respectively). Similarly, respiratory system and transpulmonary driving pressures, tidal volume, lung/chest wall mechanics, and pendelluft extent were not different between study phases. High PEEP resulted in lower or higher ΔPes, respiratory system driving pressure, and transpulmonary driving pressure according to whether this increased or decreased respiratory system compliance (r = -0.85, P < .001; r = -0.75, P < .001; r = -0.80, P < .001, respectively). PEEP-induced changes in respiratory system compliance were driven by its lung component and were dependent on the extent of PEEP-induced alveolar overinflation (r = -0.66, P = .006). High PEEP caused variable recruitment and systematic redistribution of tidal volume toward dorsal lung regions, thereby reducing dynamic strain in ventral areas (pressure support ventilation: median, 0.49; IQR, 0.37-0.83 vs median, 0.96; IQR, 0.62-1.56; P = .003; pressure-controlled intermittent mandatory ventilation: median, 0.65; IQR, 0.42-1.31 vs median, 1.14; IQR, 0.79-1.52; P = .002). All results were consistent during synchronous and asynchronous inspiratory assistance. INTERPRETATION The impact of high PEEP on ΔPes and lung stress is interindividually variable according to different effects on the respiratory system and lung compliance resulting from alveolar overinflation. High PEEP may help mitigate the risk of self-inflicted lung injury solely if it increases lung/respiratory system compliance. TRIAL REGISTRATION ClinicalTrials.gov; No.: NCT04241874; URL: www. CLINICALTRIALS gov.
Collapse
Affiliation(s)
- Giuseppe Bello
- Department of Emergency, Intensive Care Medicine and Anesthesia, Fondazione Policlinico Universitario A. Gemelli IRCCS; Rome, Italy; Istituto di Anestesiologia e Rianimazione, Università Cattolica del Sacro Cuore Rome, Italy
| | - Valentina Giammatteo
- Department of Emergency, Intensive Care Medicine and Anesthesia, Fondazione Policlinico Universitario A. Gemelli IRCCS; Rome, Italy; Istituto di Anestesiologia e Rianimazione, Università Cattolica del Sacro Cuore Rome, Italy; Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital and Harvard Medical School, Harvard University, Boston, MA
| | - Alessandra Bisanti
- Department of Emergency, Intensive Care Medicine and Anesthesia, Fondazione Policlinico Universitario A. Gemelli IRCCS; Rome, Italy; Istituto di Anestesiologia e Rianimazione, Università Cattolica del Sacro Cuore Rome, Italy
| | - Luca Delle Cese
- Department of Emergency, Intensive Care Medicine and Anesthesia, Fondazione Policlinico Universitario A. Gemelli IRCCS; Rome, Italy; Istituto di Anestesiologia e Rianimazione, Università Cattolica del Sacro Cuore Rome, Italy
| | - Tommaso Rosà
- Department of Emergency, Intensive Care Medicine and Anesthesia, Fondazione Policlinico Universitario A. Gemelli IRCCS; Rome, Italy; Istituto di Anestesiologia e Rianimazione, Università Cattolica del Sacro Cuore Rome, Italy
| | - Luca S Menga
- Department of Emergency, Intensive Care Medicine and Anesthesia, Fondazione Policlinico Universitario A. Gemelli IRCCS; Rome, Italy; Istituto di Anestesiologia e Rianimazione, Università Cattolica del Sacro Cuore Rome, Italy
| | - Luca Montini
- Department of Emergency, Intensive Care Medicine and Anesthesia, Fondazione Policlinico Universitario A. Gemelli IRCCS; Rome, Italy; Istituto di Anestesiologia e Rianimazione, Università Cattolica del Sacro Cuore Rome, Italy
| | - Teresa Michi
- Department of Emergency, Intensive Care Medicine and Anesthesia, Fondazione Policlinico Universitario A. Gemelli IRCCS; Rome, Italy; Istituto di Anestesiologia e Rianimazione, Università Cattolica del Sacro Cuore Rome, Italy
| | - Giorgia Spinazzola
- Department of Emergency, Intensive Care Medicine and Anesthesia, Fondazione Policlinico Universitario A. Gemelli IRCCS; Rome, Italy; Istituto di Anestesiologia e Rianimazione, Università Cattolica del Sacro Cuore Rome, Italy
| | - Gennaro De Pascale
- Department of Emergency, Intensive Care Medicine and Anesthesia, Fondazione Policlinico Universitario A. Gemelli IRCCS; Rome, Italy; Istituto di Anestesiologia e Rianimazione, Università Cattolica del Sacro Cuore Rome, Italy
| | - Mariano Alberto Pennisi
- Department of Emergency, Intensive Care Medicine and Anesthesia, Fondazione Policlinico Universitario A. Gemelli IRCCS; Rome, Italy; Istituto di Anestesiologia e Rianimazione, Università Cattolica del Sacro Cuore Rome, Italy
| | - Roberta Ribeiro De Santis Santiago
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital and Harvard Medical School, Harvard University, Boston, MA
| | - Lorenzo Berra
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital and Harvard Medical School, Harvard University, Boston, MA
| | - Massimo Antonelli
- Department of Emergency, Intensive Care Medicine and Anesthesia, Fondazione Policlinico Universitario A. Gemelli IRCCS; Rome, Italy; Istituto di Anestesiologia e Rianimazione, Università Cattolica del Sacro Cuore Rome, Italy
| | - Domenico Luca Grieco
- Department of Emergency, Intensive Care Medicine and Anesthesia, Fondazione Policlinico Universitario A. Gemelli IRCCS; Rome, Italy; Istituto di Anestesiologia e Rianimazione, Università Cattolica del Sacro Cuore Rome, Italy.
| |
Collapse
|
37
|
Gaulton TG, Xin Y, Victor M, Nova A, Cereda M. Imaging the pulmonary vasculature in acute respiratory distress syndrome. Nitric Oxide 2024; 147:6-12. [PMID: 38588918 PMCID: PMC11253040 DOI: 10.1016/j.niox.2024.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 03/21/2024] [Accepted: 04/03/2024] [Indexed: 04/10/2024]
Abstract
Acute respiratory distress syndrome (ARDS) is characterized by a redistribution of regional lung perfusion that impairs gas exchange. While speculative, experimental evidence suggests that perfusion redistribution may contribute to regional inflammation and modify disease progression. Unfortunately, tools to visualize and quantify lung perfusion in patients with ARDS are lacking. This review explores recent advances in perfusion imaging techniques that aim to understand the pulmonary circulation in ARDS. Dynamic contrast-enhanced computed tomography captures first-pass kinetics of intravenously injected dye during continuous scan acquisitions. Different contrast characteristics and kinetic modeling have improved its topographic measurement of pulmonary perfusion with high spatial and temporal resolution. Dual-energy computed tomography can map the pulmonary blood volume of the whole lung with limited radiation exposure, enabling its application in clinical research. Electrical impedance tomography can obtain serial topographic assessments of perfusion at the bedside in response to treatments such as inhaled nitric oxide and prone position. Ongoing technological improvements and emerging techniques will enhance lung perfusion imaging and aid its incorporation into the care of patients with ARDS.
Collapse
Affiliation(s)
- Timothy G Gaulton
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA; Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School, Boston, MA, USA.
| | - Yi Xin
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA; Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School, Boston, MA, USA
| | - Marcus Victor
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA; Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School, Boston, MA, USA; Electronics Engineering Division, Aeronautics Institute of Technology, Sao Paulo, Brazil
| | - Alice Nova
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA; Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School, Boston, MA, USA
| | - Maurizio Cereda
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA; Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
38
|
Wisse JJ, Somhorst P, Behr J, van Nieuw Amerongen AR, Gommers D, Jonkman AH. Improved filtering methods to suppress cardiovascular contamination in electrical impedance tomography recordings. Physiol Meas 2024; 45:055010. [PMID: 38697210 DOI: 10.1088/1361-6579/ad46e3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Accepted: 05/01/2024] [Indexed: 05/04/2024]
Abstract
Objective.Electrical impedance tomography (EIT) produces clinical useful visualization of the distribution of ventilation inside the lungs. The accuracy of EIT-derived parameters can be compromised by the cardiovascular signal. Removal of these artefacts is challenging due to spectral overlapping of the ventilatory and cardiovascular signal components and their time-varying frequencies. We designed and evaluated advanced filtering techniques and hypothesized that these would outperform traditional low-pass filters.Approach.Three filter techniques were developed and compared against traditional low-pass filtering: multiple digital notch filtering (MDN), empirical mode decomposition (EMD) and the maximal overlap discrete wavelet transform (MODWT). The performance of the filtering techniques was evaluated (1) in the time domain (2) in the frequency domain (3) by visual inspection. We evaluated the performance using simulated contaminated EIT data and data from 15 adult and neonatal intensive care unit patients.Main result.Each filter technique exhibited varying degrees of effectiveness and limitations. Quality measures in the time domain showed the best performance for MDN filtering. The signal to noise ratio was best for DLP, but at the cost of a high relative and removal error. MDN outbalanced the performance resulting in a good SNR with a low relative and removal error. MDN, EMD and MODWT performed similar in the frequency domain and were successful in removing the high frequency components of the data.Significance.Advanced filtering techniques have benefits compared to traditional filters but are not always better. MDN filtering outperformed EMD and MODWT regarding quality measures in the time domain. This study emphasizes the need for careful consideration when choosing a filtering approach, depending on the dataset and the clinical/research question.
Collapse
Affiliation(s)
- Jantine J Wisse
- Department of Adult Intensive Care, Erasmus Medical Centre, Rotterdam, The Netherlands
- Department of Neonatal and Pediatric Intensive Care, Erasmus Medical Centre-Sophia Children's Hospital, Rotterdam, The Netherlands
| | - Peter Somhorst
- Department of Adult Intensive Care, Erasmus Medical Centre, Rotterdam, The Netherlands
| | - Joris Behr
- Department of Adult Intensive Care, Erasmus Medical Centre, Rotterdam, The Netherlands
- Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Delft, The Netherlands
| | - Arthur R van Nieuw Amerongen
- Department of Adult Intensive Care, Erasmus Medical Centre, Rotterdam, The Netherlands
- Department of Neurology, LUMC, Leiden, The Netherlands
| | - Diederik Gommers
- Department of Adult Intensive Care, Erasmus Medical Centre, Rotterdam, The Netherlands
| | - Annemijn H Jonkman
- Department of Adult Intensive Care, Erasmus Medical Centre, Rotterdam, The Netherlands
| |
Collapse
|
39
|
Victor M, Xin Y, Alcala G, Gaulton T, Costa E, Winkler T, Berra L, Amato M, Cereda M. First-Pass Kinetics Model to Estimate Pulmonary Perfusion by Electrical Impedance Tomography During Uninterrupted Breathing. Am J Respir Crit Care Med 2024; 209:1263-1265. [PMID: 38412326 PMCID: PMC11146534 DOI: 10.1164/rccm.202310-1919le] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Accepted: 02/27/2024] [Indexed: 02/29/2024] Open
Affiliation(s)
- Marcus Victor
- Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts
- Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, Massachusetts
- Electronics Engineering Division, Aeronautics Institute of Technology, Sao Paulo, Brazil; and
| | - Yi Xin
- Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts
- Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, Massachusetts
| | - Glasiele Alcala
- Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts
- Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, Massachusetts
| | - Timothy Gaulton
- Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts
- Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, Massachusetts
| | - Eduardo Costa
- Disciplina de Pneumologia, Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, Sao Paulo, Brazil
| | - Tilo Winkler
- Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts
- Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, Massachusetts
| | - Lorenzo Berra
- Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts
- Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, Massachusetts
| | - Marcelo Amato
- Disciplina de Pneumologia, Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, Sao Paulo, Brazil
| | - Maurizio Cereda
- Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts
- Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
40
|
Songsangvorn N, Xu Y, Lu C, Rotstein O, Brochard L, Slutsky AS, Burns KEA, Zhang H. Electrical impedance tomography-guided positive end-expiratory pressure titration in ARDS: a systematic review and meta-analysis. Intensive Care Med 2024; 50:617-631. [PMID: 38512400 PMCID: PMC11078723 DOI: 10.1007/s00134-024-07362-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2023] [Accepted: 02/14/2024] [Indexed: 03/23/2024]
Abstract
PURPOSE Assessing efficacy of electrical impedance tomography (EIT) in optimizing positive end-expiratory pressure (PEEP) for acute respiratory distress syndrome (ARDS) patients to enhance respiratory system mechanics and prevent ventilator-induced lung injury (VILI), compared to traditional methods. METHODS We carried out a systematic review and meta-analysis, spanning literature from January 2012 to May 2023, sourced from Scopus, PubMed, MEDLINE (Ovid), Cochrane, and LILACS, evaluated EIT-guided PEEP strategies in ARDS versus conventional methods. Thirteen studies (3 randomized, 10 non-randomized) involving 623 ARDS patients were analyzed using random-effects models for primary outcomes (respiratory mechanics and mechanical power) and secondary outcomes (PaO2/FiO2 ratio, mortality, stays in intensive care unit (ICU), ventilator-free days). RESULTS EIT-guided PEEP significantly improved lung compliance (n = 941 cases, mean difference (MD) = 4.33, 95% confidence interval (CI) [2.94, 5.71]), reduced mechanical power (n = 148, MD = - 1.99, 95% CI [- 3.51, - 0.47]), and lowered driving pressure (n = 903, MD = - 1.20, 95% CI [- 2.33, - 0.07]) compared to traditional methods. Sensitivity analysis showed consistent positive effect of EIT-guided PEEP on lung compliance in randomized clinical trials vs. non-randomized studies pooled (MD) = 2.43 (95% CI - 0.39 to 5.26), indicating a trend towards improvement. A reduction in mortality rate (259 patients, relative risk (RR) = 0.64, 95% CI [0.45, 0.91]) was associated with modest improvements in compliance and driving pressure in three studies. CONCLUSIONS EIT facilitates real-time, individualized PEEP adjustments, improving respiratory system mechanics. Integration of EIT as a guiding tool in mechanical ventilation holds potential benefits in preventing ventilator-induced lung injury. Larger-scale studies are essential to validate and optimize EIT's clinical utility in ARDS management.
Collapse
Affiliation(s)
- Nickjaree Songsangvorn
- Keenan Research Centre for Biomedical Science and the Li Ka Shing Knowledge Institute, St. Michael's Hospital, Unity Health Toronto, Toronto, ON, Canada
- Department of Critical Care Medicine, Bhumibol Adulyadej Hospital, Bangkok, Thailand
| | - Yonghao Xu
- Keenan Research Centre for Biomedical Science and the Li Ka Shing Knowledge Institute, St. Michael's Hospital, Unity Health Toronto, Toronto, ON, Canada.
- The State Key Laboratory of Respiratory Disease, Guangzhou Institute of Respiratory Disease, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China.
| | - Cong Lu
- Keenan Research Centre for Biomedical Science and the Li Ka Shing Knowledge Institute, St. Michael's Hospital, Unity Health Toronto, Toronto, ON, Canada
| | - Ori Rotstein
- Keenan Research Centre for Biomedical Science and the Li Ka Shing Knowledge Institute, St. Michael's Hospital, Unity Health Toronto, Toronto, ON, Canada
- Department of Surgery, University of Toronto, Toronto, ON, Canada
| | - Laurent Brochard
- Keenan Research Centre for Biomedical Science and the Li Ka Shing Knowledge Institute, St. Michael's Hospital, Unity Health Toronto, Toronto, ON, Canada
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, ON, Canada
| | - Arthur S Slutsky
- Keenan Research Centre for Biomedical Science and the Li Ka Shing Knowledge Institute, St. Michael's Hospital, Unity Health Toronto, Toronto, ON, Canada
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, ON, Canada
| | - Karen E A Burns
- Keenan Research Centre for Biomedical Science and the Li Ka Shing Knowledge Institute, St. Michael's Hospital, Unity Health Toronto, Toronto, ON, Canada
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, ON, Canada
| | - Haibo Zhang
- Keenan Research Centre for Biomedical Science and the Li Ka Shing Knowledge Institute, St. Michael's Hospital, Unity Health Toronto, Toronto, ON, Canada.
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, ON, Canada.
- Department of Physiology, University of Toronto, Toronto, ON, Canada.
- Department of Anesthesiology and Pain Medicine, University of Toronto, Toronto, ON, Canada.
| |
Collapse
|
41
|
Sanchez Giralt JA, Tusman G, Wallin M, Hallback M, Perez Lucendo A, Sanchez Galindo M, Abad Santamaria B, Paz Calzada E, Garcia Garcia P, Rodriguez Huerta D, Canabal Berlanga A, Suarez-Sipmann F. Clinical validation of a capnodynamic method for measuring end-expiratory lung volume in critically ill patients. Crit Care 2024; 28:142. [PMID: 38689313 PMCID: PMC11059761 DOI: 10.1186/s13054-024-04928-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Accepted: 04/21/2024] [Indexed: 05/02/2024] Open
Abstract
RATIONALE End-expiratory lung volume (EELV) is reduced in mechanically ventilated patients, especially in pathologic conditions. The resulting heterogeneous distribution of ventilation increases the risk for ventilation induced lung injury. Clinical measurement of EELV however, remains difficult. OBJECTIVE Validation of a novel continuous capnodynamic method based on expired carbon dioxide (CO2) kinetics for measuring EELV in mechanically ventilated critically-ill patients. METHODS Prospective study of mechanically ventilated patients scheduled for a diagnostic computed tomography exploration. Comparisons were made between absolute and corrected EELVCO2 values, the latter accounting for the amount of CO2 dissolved in lung tissue, with the reference EELV measured by computed tomography (EELVCT). Uncorrected and corrected EELVCO2 was compared with total CT volume (density compartments between - 1000 and 0 Hounsfield units (HU) and functional CT volume, including density compartments of - 1000 to - 200HU eliminating regions of increased shunt. We used comparative statistics including correlations and measurement of accuracy and precision by the Bland Altman method. MEASUREMENTS AND MAIN RESULTS Of the 46 patients included in the final analysis, 25 had a diagnosis of ARDS (24 of which COVID-19). Both EELVCT and EELVCO2 were significantly reduced (39 and 40% respectively) when compared with theoretical values of functional residual capacity (p < 0.0001). Uncorrected EELVCO2 tended to overestimate EELVCT with a correlation r2 0.58; Bias - 285 and limits of agreement (LoA) (+ 513 to - 1083; 95% CI) ml. Agreement improved for the corrected EELVCO2 to a Bias of - 23 and LoA of (+ 763 to - 716; 95% CI) ml. The best agreement of the method was obtained by comparison of corrected EELVCO2 with functional EELVCT with a r2 of 0.59; Bias - 2.75 (+ 755 to - 761; 95% CI) ml. We did not observe major differences in the performance of the method between ARDS (most of them COVID related) and non-ARDS patients. CONCLUSION In this first validation in critically ill patients, the capnodynamic method provided good estimates of both total and functional EELV. Bias improved after correcting EELVCO2 for extra-alveolar CO2 content when compared with CT estimated volume. If confirmed in further validations EELVCO2 may become an attractive monitoring option for continuously monitor EELV in critically ill mechanically ventilated patients. TRIAL REGISTRATION clinicaltrials.gov (NCT04045262).
Collapse
Affiliation(s)
- J A Sanchez Giralt
- Department of Intensive Care, Hospital Universitario de La Princesa, Diego de León 62, 28006, Madrid, Spain
| | - G Tusman
- Department of Anesthesia, Hospital Privado de Comunidad, Mar del Plata, Argentina
| | - M Wallin
- Department of Physiology and Pharmacology (FYFA), C3, Eriksson Lars Group, Karolinska Institute, Stockholm, Sweden
| | | | - A Perez Lucendo
- Department of Intensive Care, Hospital Universitario de La Princesa, Diego de León 62, 28006, Madrid, Spain
| | - M Sanchez Galindo
- Department of Intensive Care, Hospital Universitario de La Princesa, Diego de León 62, 28006, Madrid, Spain
| | - B Abad Santamaria
- Department of Intensive Care, Hospital Universitario de La Princesa, Diego de León 62, 28006, Madrid, Spain
| | - E Paz Calzada
- Deparment of Radiology, Hospital Universitario de la Princesa, Madrid, España
| | - P Garcia Garcia
- Deparment of Radiology, Hospital Universitario de la Princesa, Madrid, España
| | - D Rodriguez Huerta
- Department of Intensive Care, Hospital Universitario de La Princesa, Diego de León 62, 28006, Madrid, Spain
| | - A Canabal Berlanga
- Department of Intensive Care, Hospital Universitario de La Princesa, Diego de León 62, 28006, Madrid, Spain
| | - Fernando Suarez-Sipmann
- Department of Intensive Care, Hospital Universitario de La Princesa, Diego de León 62, 28006, Madrid, Spain.
- CIBER Enfermedades Respiratorias, Instituto de Salud Carlos III, Madrid, Spain.
- Hedenstierna Laboratory, Uppsala University, Uppsala, Sweden.
| |
Collapse
|
42
|
Simonte R, Cammarota G, Vetrugno L, De Robertis E, Longhini F, Spadaro S. Advanced Respiratory Monitoring during Extracorporeal Membrane Oxygenation. J Clin Med 2024; 13:2541. [PMID: 38731069 PMCID: PMC11084162 DOI: 10.3390/jcm13092541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2024] [Revised: 04/16/2024] [Accepted: 04/23/2024] [Indexed: 05/13/2024] Open
Abstract
Advanced respiratory monitoring encompasses a diverse range of mini- or noninvasive tools used to evaluate various aspects of respiratory function in patients experiencing acute respiratory failure, including those requiring extracorporeal membrane oxygenation (ECMO) support. Among these techniques, key modalities include esophageal pressure measurement (including derived pressures), lung and respiratory muscle ultrasounds, electrical impedance tomography, the monitoring of diaphragm electrical activity, and assessment of flow index. These tools play a critical role in assessing essential parameters such as lung recruitment and overdistention, lung aeration and morphology, ventilation/perfusion distribution, inspiratory effort, respiratory drive, respiratory muscle contraction, and patient-ventilator synchrony. In contrast to conventional methods, advanced respiratory monitoring offers a deeper understanding of pathological changes in lung aeration caused by underlying diseases. Moreover, it allows for meticulous tracking of responses to therapeutic interventions, aiding in the development of personalized respiratory support strategies aimed at preserving lung function and respiratory muscle integrity. The integration of advanced respiratory monitoring represents a significant advancement in the clinical management of acute respiratory failure. It serves as a cornerstone in scenarios where treatment strategies rely on tailored approaches, empowering clinicians to make informed decisions about intervention selection and adjustment. By enabling real-time assessment and modification of respiratory support, advanced monitoring not only optimizes care for patients with acute respiratory distress syndrome but also contributes to improved outcomes and enhanced patient safety.
Collapse
Affiliation(s)
- Rachele Simonte
- Department of Medicine and Surgery, Università degli Studi di Perugia, 06100 Perugia, Italy; (R.S.); (E.D.R.)
| | - Gianmaria Cammarota
- Department of Translational Medicine, Università del Piemonte Orientale, 28100 Novara, Italy;
| | - Luigi Vetrugno
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, 66100 Chieti, Italy;
| | - Edoardo De Robertis
- Department of Medicine and Surgery, Università degli Studi di Perugia, 06100 Perugia, Italy; (R.S.); (E.D.R.)
| | - Federico Longhini
- Department of Medical and Surgical Sciences, Università della Magna Graecia, 88100 Catanzaro, Italy
- Anesthesia and Intensive Care Unit, “R. Dulbecco” University Hospital, 88100 Catanzaro, Italy
| | - Savino Spadaro
- Department of Morphology, Surgery and Experimental Medicine, University of Ferrara, 44100 Ferrara, Italy;
| |
Collapse
|
43
|
Wisse JJ, Goos TG, Jonkman AH, Somhorst P, Reiss IKM, Endeman H, Gommers D. Electrical Impedance Tomography as a monitoring tool during weaning from mechanical ventilation: an observational study during the spontaneous breathing trial. Respir Res 2024; 25:179. [PMID: 38664685 PMCID: PMC11044327 DOI: 10.1186/s12931-024-02801-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 04/02/2024] [Indexed: 04/29/2024] Open
Abstract
BACKGROUND Prolonged weaning from mechanical ventilation is associated with poor clinical outcome. Therefore, choosing the right moment for weaning and extubation is essential. Electrical Impedance Tomography (EIT) is a promising innovative lung monitoring technique, but its role in supporting weaning decisions is yet uncertain. We aimed to evaluate physiological trends during a T-piece spontaneous breathing trail (SBT) as measured with EIT and the relation between EIT parameters and SBT success or failure. METHODS This is an observational study in which twenty-four adult patients receiving mechanical ventilation performed an SBT. EIT monitoring was performed around the SBT. Multiple EIT parameters including the end-expiratory lung impedance (EELI), delta Tidal Impedance (ΔZ), Global Inhomogeneity index (GI), Rapid Shallow Breathing Index (RSBIEIT), Respiratory Rate (RREIT) and Minute Ventilation (MVEIT) were computed on a breath-by-breath basis from stable tidal breathing periods. RESULTS EELI values dropped after the start of the SBT (p < 0.001) and did not recover to baseline after restarting mechanical ventilation. The ΔZ dropped (p < 0.001) but restored to baseline within seconds after restarting mechanical ventilation. Five patients failed the SBT, the GI (p = 0.01) and transcutaneous CO2 (p < 0.001) values significantly increased during the SBT in patients who failed the SBT compared to patients with a successful SBT. CONCLUSION EIT has the potential to assess changes in ventilation distribution and quantify the inhomogeneity of the lungs during the SBT. High lung inhomogeneity was found during SBT failure. Insight into physiological trends for the individual patient can be obtained with EIT during weaning from mechanical ventilation, but its role in predicting weaning failure requires further study.
Collapse
Affiliation(s)
- Jantine J Wisse
- Department of Adult Intensive Care, Erasmus Medical Centre, Rotterdam, the Netherlands.
- Department of Neonatal and Pediatric Intensive Care, Erasmus Medical Centre - Sophia Children's Hospital, Rotterdam, The Netherlands.
| | - Tom G Goos
- Department of Neonatal and Pediatric Intensive Care, Erasmus Medical Centre - Sophia Children's Hospital, Rotterdam, The Netherlands
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Delft, The Netherlands
| | - Annemijn H Jonkman
- Department of Adult Intensive Care, Erasmus Medical Centre, Rotterdam, the Netherlands
| | - Peter Somhorst
- Department of Adult Intensive Care, Erasmus Medical Centre, Rotterdam, the Netherlands
| | - Irwin K M Reiss
- Department of Neonatal and Pediatric Intensive Care, Erasmus Medical Centre - Sophia Children's Hospital, Rotterdam, The Netherlands
| | - Henrik Endeman
- Department of Adult Intensive Care, Erasmus Medical Centre, Rotterdam, the Netherlands
| | - Diederik Gommers
- Department of Adult Intensive Care, Erasmus Medical Centre, Rotterdam, the Netherlands
| |
Collapse
|
44
|
Frerichs I, Becher T, Zhao Z. Methodological considerations in personalized methods for PEEP optimization with electrical impedance tomography. Ann Intensive Care 2024; 14:62. [PMID: 38642234 PMCID: PMC11032297 DOI: 10.1186/s13613-024-01288-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Accepted: 04/02/2024] [Indexed: 04/22/2024] Open
Affiliation(s)
- Inéz Frerichs
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center, Schleswig-Holstein, Campus Kiel, Kiel, Germany.
| | - Tobias Becher
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center, Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Zhanqi Zhao
- School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, China
- Department of Critical Care Medicine, Peking Union Medical College Hospital, Beijing, China
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| |
Collapse
|
45
|
Rahtu M, Frerichs I, Pokka T, Becher T, Peltoniemi O, Kallio M. Effect of body position on ventilation distribution in healthy newborn infants: an observational study. Arch Dis Child Fetal Neonatal Ed 2024; 109:322-327. [PMID: 38071525 DOI: 10.1136/archdischild-2023-325967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 11/15/2023] [Indexed: 04/20/2024]
Abstract
OBJECTIVES Newborn infants have unique respiratory physiology compared with older children and adults due to their lungs' structural and functional immaturity and highly compliant chest wall. To date, ventilation distribution has seldom been studied in this age group. This study aims to assess the effect of body position on ventilation distribution in spontaneously breathing healthy neonates. DESIGN Prospective observational study. SETTING Maternity wards of Oulu University Hospital. PATIENTS 20 healthy, spontaneously breathing, newborn infants. INTERVENTIONS Electrical impedance tomography data were recorded with a 32-electrode belt (Sentec AG, Landquart, Switzerland) in six different body positions in random order. Ventilation distribution was retrospectively assessed 10 minutes after each position change. MAIN OUTCOME MEASURES In each position, regional tidal impedance variation (ΔZ) and ventral-to-dorsal and right-to-left centre of ventilation were measured. RESULTS The mean global ΔZ was the largest in supine position and it was smaller in prone and lateral positions. Yet, global ΔZ did not differ in supine positions, ventilation distribution was more directed towards the non-dependent lung region in supine tilted position (p<0.001). In prone, a reduction of global ΔZ was observed (p<0.05) corresponding to an amount of 10% of global tidal variation in supine position. In both lateral positions, tidal ventilation was distributed more to the corresponding non-dependent lung region. CONCLUSIONS Prone or lateral body positioning in healthy spontaneously breathing newborns leads to a redistribution of ventilation to the non-dependent lung regions and at the same time global tidal volume is reduced as compared with supine.
Collapse
Affiliation(s)
- Marika Rahtu
- Department of Pediatrics and Adolescent Medicine and Research Unit of Clinical Medicine, Oulu University Hospital, Oulu, Finland
| | - Inéz Frerichs
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein Campus Kiel, Kiel, Schleswig-Holstein, Germany
| | - Tytti Pokka
- Department of Pediatrics and Adolescent Medicine and Research Unit of Clinical Medicine, Oulu University Hospital, Oulu, Finland
- Research Service Unit, Oulu University Hospital, Oulu, Finland
| | - Tobias Becher
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein Campus Kiel, Kiel, Schleswig-Holstein, Germany
| | - Outi Peltoniemi
- Department of Pediatrics and Adolescent Medicine and Research Unit of Clinical Medicine, Oulu University Hospital, Oulu, Finland
| | - Merja Kallio
- Department of Pediatrics and Adolescent Medicine and Research Unit of Clinical Medicine, Oulu University Hospital, Oulu, Finland
| |
Collapse
|
46
|
Shah NM, Apps C, Kaltsakas G, Madden-Scott S, Suh ES, D'Cruz RF, Arbane G, Patout M, Lhuillier E, Hart N, Murphy PB. The Effect of Pressure Changes During Mechanical Insufflation-Exsufflation on Respiratory and Airway Physiology. Chest 2024; 165:929-941. [PMID: 37844796 DOI: 10.1016/j.chest.2023.10.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 09/30/2023] [Accepted: 10/03/2023] [Indexed: 10/18/2023] Open
Abstract
BACKGROUND Respiratory muscle weakness can impair cough function, leading to lower respiratory tract infections. These infections are an important contributor to morbidity and mortality in patients with neuromuscular disease. Mechanical insufflation-exsufflation (MIE) is used to augment cough function in these patients. Although MIE is widely used, there are few data to advise on the optimal technique. Since the introduction of MIE, the recommended pressures to be delivered have increased. There are concerns regarding the use of higher pressures and their potential to cause lung derecruitment and upper airway closure. RESEARCH QUESTION What is the impact of high-pressure MIE (HP-MIE) on lung recruitment, respiratory drive, upper airway flow, and patient comfort, compared with low-pressure MIE (LP-MIE), in patients with respiratory muscle weakness? STUDY DESIGN AND METHODS Clinically stable patients using domiciliary MIE with respiratory muscle weakness secondary to Duchenne muscle dystrophy, spinal cord injury, or long-term tracheostomy ventilation received LP-MIE (30/-30 cm H2O) and HP-MIE (60/-60 cm H2O) in a random sequence. Lung recruitment, neural respiratory drive, and cough peak expiratory flow were measured throughout, and patients reported comfort and breathlessness following each intervention. RESULTS A total of 29 patients (10 with Duchenne muscle dystrophy, eight with spinal cord injury, and 11 with long-term tracheostomy ventilation) were included in this study. HP-MIE augmented cough peak expiratory flow compared with LP-MIE (mean cough peak expiratory flow HP-MIE 228 ± 81 L/min vs LP-MIE 179 ± 67 L/min; P = .0001) without any significant change in lung recruitment, neural respiratory drive, or patient-reported breathlessness. However, in patients with more pronounced respiratory muscle weakness, HP-MIE resulted in an increased rate of upper airway closure and patient discomfort that may have an impact on clinical efficacy. INTERPRETATION HP-MIE did not lead to lung derecruitment or breathlessness compared with LP-MIE. However, it was poorly tolerated in individuals with advanced respiratory muscle weakness. HP-MIE generates more upper airway closure than LP-MIE, which may be missed if cough peak expiratory flow is used as the sole titration target. CLINICAL TRIAL REGISTRATION ClinicalTrials.gov; No.: NCT02753959; URL: www. CLINICALTRIALS gov.
Collapse
Affiliation(s)
- Neeraj M Shah
- Lane Fox Respiratory Service, St Thomas' Hospital, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; Lane Fox Clinical Respiratory Physiology Centre, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; Centre for Human and Applied Physiological Sciences (CHAPS), King's College London, London, United Kingdom.
| | - Chloe Apps
- Critical Care, St Thomas' Hospital, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; GKT School of Medical Education, King's College London, London, United Kingdom
| | - Georgios Kaltsakas
- Lane Fox Respiratory Service, St Thomas' Hospital, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; Lane Fox Clinical Respiratory Physiology Centre, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; Centre for Human and Applied Physiological Sciences (CHAPS), King's College London, London, United Kingdom
| | - Sophie Madden-Scott
- Lane Fox Respiratory Service, St Thomas' Hospital, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; Critical Care, St Thomas' Hospital, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; Lane Fox Clinical Respiratory Physiology Centre, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Eui-Sik Suh
- Lane Fox Respiratory Service, St Thomas' Hospital, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; Lane Fox Clinical Respiratory Physiology Centre, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; Centre for Human and Applied Physiological Sciences (CHAPS), King's College London, London, United Kingdom
| | - Rebecca F D'Cruz
- Lane Fox Respiratory Service, St Thomas' Hospital, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; Lane Fox Clinical Respiratory Physiology Centre, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; Centre for Human and Applied Physiological Sciences (CHAPS), King's College London, London, United Kingdom
| | - Gill Arbane
- Lane Fox Respiratory Service, St Thomas' Hospital, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; Lane Fox Clinical Respiratory Physiology Centre, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Maxime Patout
- AP-HP, Groupe Hospitalier Universitaire APHP-Sorbonne Université, site Pitié-Salpêtrière, Service des Pathologies du Sommeil (Département R3S), Paris, France; Sorbonne Université, INSERM, UMRS1158 Neurophysiologie Respiratoire Expérimentale et Clinique, Paris, France
| | | | - Nicholas Hart
- Lane Fox Respiratory Service, St Thomas' Hospital, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; Lane Fox Clinical Respiratory Physiology Centre, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; Centre for Human and Applied Physiological Sciences (CHAPS), King's College London, London, United Kingdom
| | - Patrick B Murphy
- Lane Fox Respiratory Service, St Thomas' Hospital, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; Lane Fox Clinical Respiratory Physiology Centre, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; Centre for Human and Applied Physiological Sciences (CHAPS), King's College London, London, United Kingdom
| |
Collapse
|
47
|
Ribeiro BM, Tucci MR, Victor Júnior MH, Melo JR, Gomes S, Nakamura MAM, Morais CCA, Beraldo MA, Lima CAS, Alcala GC, Amato MBP. Influence of Fractional Inspired Oxygen Tension on Lung Perfusion Distribution, Regional Ventilation, and Lung Volume during Mechanical Ventilation of Supine Healthy Swine. Anesthesiology 2024; 140:752-764. [PMID: 38207290 DOI: 10.1097/aln.0000000000004903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2024]
Abstract
BACKGROUND Lower fractional inspired oxygen tension (Fio2) during general anesthesia can reduce lung atelectasis. The objectives are to evaluate the effect of two Fio2 (0.4 and 1) during low positive end-expiratory pressure (PEEP) ventilation over lung perfusion distribution, volume, and regional ventilation. These variables were evaluated at two PEEP levels and unilateral lung atelectasis. METHODS In this exploratory study, 10 healthy female piglets (32.3 ± 3.4 kg) underwent mechanical ventilation in two atelectasis models: (1) bilateral gravitational atelectasis (n = 6), induced by changes in PEEP and Fio2 in three combinations: high PEEP with low Fio2 (Fio2 = 0.4), zero PEEP (PEEP0) with low Fio2 (Fio2 = 0.4), and PEEP0 with high Fio2 (Fio2 = 1); and (2) unilateral atelectasis (n = 6), induced by left bronchial occlusion, with the left lung aerated (Fio2 = 0.21) and low aerated (Fio2 = 1; n = 5 for this step). Measurements were conducted after 10 min in each step, encompassing assessment of respiratory mechanics, oxygenation, and hemodynamics; lung ventilation and perfusion by electrical impedance tomography; and lung aeration and perfusion by computed tomography. RESULTS During bilateral gravitational atelectasis, PEEP reduction increased atelectasis in dorsal regions, decreased respiratory compliance, and distributed lung ventilation to ventral regions with a parallel shift of perfusion to the same areas. With PEEP0, there were no differences between low and high Fio2 in respiratory compliance (23.9 ± 6.5 ml/cm H2O vs. 21.9 ± 5.0; P = 0.441), regional ventilation, and regional perfusion, despite higher lung collapse (18.6 ± 7.6% vs. 32.7 ± 14.5%; P = 0.045) with high Fio2. During unilateral lung atelectasis, the deaerated lung had a lower shunt (19.3 ± 3.6% vs. 25.3 ± 5.5%; P = 0.045) and lower computed tomography perfusion to the left lung (8.8 ± 1.8% vs. 23.8 ± 7.1%; P = 0.007). CONCLUSIONS PEEP0 with low Fio2, compared with high Fio2, did not produce significant changes in respiratory system compliance, regional lung ventilation, and perfusion despite significantly lower lung collapse. After left bronchial occlusion, the shrinkage of the parenchyma with Fio2 = 1 enhanced hypoxic pulmonary vasoconstriction, reducing intrapulmonary shunt and perfusion of the nonventilated areas. EDITOR’S PERSPECTIVE
Collapse
Affiliation(s)
- Bruno M Ribeiro
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Mauro R Tucci
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Marcus H Victor Júnior
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil; Electronics Engineering, Aeronautics Institute of Technology, Sao Jose dos Campos, Brazil
| | - Jose R Melo
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Susimeire Gomes
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Maria A M Nakamura
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Caio C A Morais
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Marcelo A Beraldo
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Cristhiano A S Lima
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Glasiele C Alcala
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Marcelo B P Amato
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| |
Collapse
|
48
|
Lin N, Fan CJ, Li FY, Luo HR, Li YM, Duggal A, Benn BS, Yan T, Pan LL, Lai ZM. Research trends and hotspots in the field of electrical impedance tomography for mechanical ventilation: a bibliometric analysis. J Thorac Dis 2024; 16:2070-2081. [PMID: 38617762 PMCID: PMC11009609 DOI: 10.21037/jtd-24-98] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Accepted: 03/01/2024] [Indexed: 04/16/2024]
Abstract
Background Electrical impedance tomography (EIT) is a relatively recent functional imaging technique that is both noninvasive and radiation free. EIT measures the associated voltage when a weak current is applied to the surface of the human body to determine the distribution of electrical resistance within tissues. We performed a bibliometrics-based review to explore the geographic hotspots of current research and future trends developing in the field of EIT for mechanical ventilation. Methods The Web of Science database was searched from its inception to June 25, 2023. CiteSpace software was used to visualize and analyze the relevant literature and identify the most impactful literature, trends, and hotspots. Results 363 articles describing EIT use in mechanical ventilation were identified. A fluctuating growth in the number of publications was observed from 1998 to 2023. Germany had the highest number of articles (n=154), followed by Italy (n=53) and China (n=52). A cluster analysis of keyword co-occurrence revealed that "titration", "ventilator-related lung injury", and "oxygenation" were the most actively researched terms associated with the use of EIT in mechanically ventilated patients. Conclusions Significant progress has been made in EIT research for mechanical ventilation. EIT research is limited to a small number of countries with a present research focus on the prevention and treatment of ventilator-related lung injury, oxygenation status, and prone ventilation. These topics are expected to remain research hotspots in the future.
Collapse
Affiliation(s)
- Nan Lin
- Department of Anesthesiology, Fujian Medical University Union Hospital, Fuzhou, China
| | - Chong-Jiu Fan
- Department of Anesthesiology, Fujian Medical University Union Hospital, Fuzhou, China
| | - Fu-Yuan Li
- Department of Anesthesiology, Fujian Medical University Union Hospital, Fuzhou, China
| | - Hui-Rong Luo
- Department of Anesthesiology, Fujian Medical University Union Hospital, Fuzhou, China
| | - Yu-Mei Li
- Department of Anesthesiology, Fujian Medical University Union Hospital, Fuzhou, China
| | - Abhijit Duggal
- Department of Critical Care Medicine, Respiratory Institute, Cleveland Clinic Foundation, Cleveland, OH, USA
- Department of Medicine, Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, OH, USA
| | - Bryan S. Benn
- Pulmonary Department, Respiratory Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Ting Yan
- Department of Anesthesiology, Fujian Medical University Union Hospital, Fuzhou, China
| | - Ling-Li Pan
- Department of Anesthesiology, Fujian Medical University Union Hospital, Fuzhou, China
| | - Zhong-Meng Lai
- Department of Anesthesiology, Fujian Medical University Union Hospital, Fuzhou, China
| |
Collapse
|
49
|
Pupier T, Gallo É, Bonnardel E, Boisselier C, Perrier V, Repusseau B, Rozé H. Daily Evolution of Lung Dependent-Area Collapse Between Prone Position Sessions in ARDS Evaluated by Electrical Impedance Tomography. Respir Care 2024; 69:470-473. [PMID: 38471736 PMCID: PMC11108115 DOI: 10.4187/respcare.11292] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/14/2024]
Affiliation(s)
- Thomas Pupier
- Drs Pupier, Gallo, Bonnardel, Boisselier, Perrier, and Repusseau are affiliated with CHU de Bordeaux, Service d'Anesthésie Réanimation Thoraco-Abdominale, F-33600 Pessac, France. Dr Rozé is affiliated with CHU de Bordeaux, Service d'Anesthésie Réanimation Thoraco-Abdominale, F-33600 Pessac, France; Réanimation Polyvalente, Centre Hospitalier Côte Basque, F64100 Bayonne, Centre Hospitalier Côte Basque, F64100 Bayonne, France; Université de Bordeaux, F-33400 Talence, France
| | - Éloïse Gallo
- Drs Pupier, Gallo, Bonnardel, Boisselier, Perrier, and Repusseau are affiliated with CHU de Bordeaux, Service d'Anesthésie Réanimation Thoraco-Abdominale, F-33600 Pessac, France. Dr Rozé is affiliated with CHU de Bordeaux, Service d'Anesthésie Réanimation Thoraco-Abdominale, F-33600 Pessac, France; Réanimation Polyvalente, Centre Hospitalier Côte Basque, F64100 Bayonne, Centre Hospitalier Côte Basque, F64100 Bayonne, France; Université de Bordeaux, F-33400 Talence, France
| | - Eline Bonnardel
- Drs Pupier, Gallo, Bonnardel, Boisselier, Perrier, and Repusseau are affiliated with CHU de Bordeaux, Service d'Anesthésie Réanimation Thoraco-Abdominale, F-33600 Pessac, France. Dr Rozé is affiliated with CHU de Bordeaux, Service d'Anesthésie Réanimation Thoraco-Abdominale, F-33600 Pessac, France; Réanimation Polyvalente, Centre Hospitalier Côte Basque, F64100 Bayonne, Centre Hospitalier Côte Basque, F64100 Bayonne, France; Université de Bordeaux, F-33400 Talence, France
| | - Clément Boisselier
- Drs Pupier, Gallo, Bonnardel, Boisselier, Perrier, and Repusseau are affiliated with CHU de Bordeaux, Service d'Anesthésie Réanimation Thoraco-Abdominale, F-33600 Pessac, France. Dr Rozé is affiliated with CHU de Bordeaux, Service d'Anesthésie Réanimation Thoraco-Abdominale, F-33600 Pessac, France; Réanimation Polyvalente, Centre Hospitalier Côte Basque, F64100 Bayonne, Centre Hospitalier Côte Basque, F64100 Bayonne, France; Université de Bordeaux, F-33400 Talence, France
| | - Virginie Perrier
- Drs Pupier, Gallo, Bonnardel, Boisselier, Perrier, and Repusseau are affiliated with CHU de Bordeaux, Service d'Anesthésie Réanimation Thoraco-Abdominale, F-33600 Pessac, France. Dr Rozé is affiliated with CHU de Bordeaux, Service d'Anesthésie Réanimation Thoraco-Abdominale, F-33600 Pessac, France; Réanimation Polyvalente, Centre Hospitalier Côte Basque, F64100 Bayonne, Centre Hospitalier Côte Basque, F64100 Bayonne, France; Université de Bordeaux, F-33400 Talence, France
| | - Benjamin Repusseau
- Drs Pupier, Gallo, Bonnardel, Boisselier, Perrier, and Repusseau are affiliated with CHU de Bordeaux, Service d'Anesthésie Réanimation Thoraco-Abdominale, F-33600 Pessac, France. Dr Rozé is affiliated with CHU de Bordeaux, Service d'Anesthésie Réanimation Thoraco-Abdominale, F-33600 Pessac, France; Réanimation Polyvalente, Centre Hospitalier Côte Basque, F64100 Bayonne, Centre Hospitalier Côte Basque, F64100 Bayonne, France; Université de Bordeaux, F-33400 Talence, France
| | - Hadrien Rozé
- Drs Pupier, Gallo, Bonnardel, Boisselier, Perrier, and Repusseau are affiliated with CHU de Bordeaux, Service d'Anesthésie Réanimation Thoraco-Abdominale, F-33600 Pessac, France. Dr Rozé is affiliated with CHU de Bordeaux, Service d'Anesthésie Réanimation Thoraco-Abdominale, F-33600 Pessac, France; Réanimation Polyvalente, Centre Hospitalier Côte Basque, F64100 Bayonne, Centre Hospitalier Côte Basque, F64100 Bayonne, France; Université de Bordeaux, F-33400 Talence, France.
| |
Collapse
|
50
|
Yang L, Gao Z, Cao X, Sun S, Wang C, Wang H, Dai J, Liu Y, Qin Y, Dai M, Guo W, Zhang B, Zhao K, Zhao Z. Electrical impedance tomography as a bedside assessment tool for COPD treatment during hospitalization. Front Physiol 2024; 15:1352391. [PMID: 38562620 PMCID: PMC10982416 DOI: 10.3389/fphys.2024.1352391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Accepted: 03/06/2024] [Indexed: 04/04/2024] Open
Abstract
For patients with chronic obstructive pulmonary disease (COPD), the assessment of the treatment efficacy during hospitalization is of importance to the optimization of clinical treatments. Conventional spirometry might not be sensitive enough to capture the regional lung function development. The study aimed to evaluate the feasibility of using electrical impedance tomography (EIT) as an objective bedside evaluation tool for the treatment of acute exacerbation of COPD (AECOPD). Consecutive patients who required hospitalization due to AECOPD were included prospectively. EIT measurements were conducted at the time of admission and before the discharge simultaneously when a forced vital capacity maneuver was conducted. EIT-based heterogeneity measures of regional lung function were calculated based on the impedance changes over time. Surveys for attending doctors and patients were designed to evaluate the ease of use, feasibility, and overall satisfaction level to understand the acceptability of EIT measurements. Patient-reported outcome assessments were conducted. User's acceptance of EIT technology was investigated with a five-dimension survey. A total of 32 patients were included, and 8 patients were excluded due to the FVC maneuver not meeting the ATS criteria. Spirometry-based lung function was improved during hospitalization but not significantly different (FEV1 %pred.: 35.8% ± 6.7% vs. 45.3% ± 8.8% at admission vs. discharge; p = 0.11. FVC %pred.: 67.8% ± 0.4% vs. 82.6% ± 5.0%; p = 0.15. FEV1/FVC: 0.41 ± 0.09 vs. 0.42 ± 0.07, p = 0.71). The symptoms of COPD were significantly improved, but the correlations between the improvement of symptoms and spirometry FEV1 and FEV1/FVC were low (R = 0.1 and -0.01, respectively). The differences in blood gasses and blood tests were insignificant. All but one EIT-based regional lung function parameter were significantly improved after hospitalization. The results highly correlated with the patient-reported outcome assessment (R > 0.6, p < 0.001). The overall acceptability score of EIT measurement for both attending physicians and patients was high (4.1 ± 0.8 for physicians, 4.5 ± 0.5 for patients out of 5). These results demonstrated that it was feasible and acceptable to use EIT as an objective bedside evaluation tool for COPD treatment efficacy.
Collapse
Affiliation(s)
- Lin Yang
- Department of Aerospace Medicine, Air Force Medical University, Xi’an, China
| | - Zhijun Gao
- Department of Aerospace Medicine, Air Force Medical University, Xi’an, China
| | - Xinsheng Cao
- Department of Aerospace Medicine, Air Force Medical University, Xi’an, China
| | - Shuying Sun
- Department of Pulmonary and Critical Care Medicine, 986th Hospital of Air Force, Air Force Medical University, Xi’an, China
| | - Chunchen Wang
- Department of Aerospace Medicine, Air Force Medical University, Xi’an, China
| | - Hang Wang
- Department of Aerospace Medicine, Air Force Medical University, Xi’an, China
| | - Jing Dai
- Department of Aerospace Medicine, Air Force Medical University, Xi’an, China
| | - Yang Liu
- Department of Aerospace Medicine, Air Force Medical University, Xi’an, China
| | - Yilong Qin
- Department of Aerospace Medicine, Air Force Medical University, Xi’an, China
| | - Meng Dai
- Department of Biomedical Engineering, Air Force Medical University, Xi’an, China
| | - Wei Guo
- Department of Pulmonary and Critical Care Medicine, 986th Hospital of Air Force, Air Force Medical University, Xi’an, China
| | - Binghua Zhang
- Department of Pulmonary and Critical Care Medicine, 986th Hospital of Air Force, Air Force Medical University, Xi’an, China
| | - Ke Zhao
- Department of Pulmonary and Critical Care Medicine, 986th Hospital of Air Force, Air Force Medical University, Xi’an, China
| | - Zhanqi Zhao
- School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, China
- Department of Critical Care Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China
| |
Collapse
|