1
|
Leclerc A, Deboeuf L, Elia A, Aboubakr O, Planet M, Bedioui A, Rault F, Faisant M, Roux A, Simboli GA, Moiraghi A, Gaberel T, Pallud J, Emery E, Zanello M. Safety and efficacy of frameless stereotactic robot-assisted intraparenchymal brain lesion biopsies versus image-guided biopsies: a bicentric comparative study. Acta Neurochir (Wien) 2024; 166:67. [PMID: 38319393 DOI: 10.1007/s00701-024-05912-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Accepted: 11/06/2023] [Indexed: 02/07/2024]
Abstract
PURPOSE User-friendly robotic assistance and image-guided tools have been developed in the past decades for intraparenchymal brain lesion biopsy. These two methods are gradually becoming well accepted and are performed at the discretion of the neurosurgical teams. However, only a few data comparing their effectiveness and safety are available. METHODS Population-based parallel cohorts were followed from two French university hospitals with different surgical methods and defined geographical catchment regions (September 2019 to September 2022). In center A, frameless robot-assisted stereotactic intraparenchymal brain lesion biopsies were performed, while image-guided intraparenchymal brain lesion biopsies were performed in center B. Pre-and postoperative clinical, radiological, and histomolecular features were retrospectively collected and compared. RESULTS Two hundred fifty patients were included: 131 frameless robot-assisted stereotactic intraparenchymal brain lesion biopsies in center A and 119 image-guided biopsies in center B. The clinical, radiological, and histomolecular features were comparable between the two groups. The diagnostic yield (96.2% and 95.8% respectively; p = 1.000) and the overall postoperative complications rates (13% and 14%, respectively; p = 0.880) did not differ between the two groups. The mean duration of the surgical procedure was longer in the robot-assisted group (61.9 ± 25.3 min, range 23-150) than in the image-guided group (47.4 ± 11.8 min, range 25-81, p < 0.001). In the subgroup of patients with anticoagulant and/or antiplatelet therapy administered preoperatively, the intracerebral hemorrhage > 10 mm on postoperative CT scan was higher in the image-guided group (36.8%) than in the robot-assisted group (5%, p < 0.001). CONCLUSION In our bicentric comparative study, robot-assisted stereotactic and image-guided biopsies have two main differences (shorter time but more frequent postoperative hematoma for image-guided biopsies); however, both techniques are demonstrated to be safe and efficient.
Collapse
Affiliation(s)
- Arthur Leclerc
- Department of Neurosurgery, Caen University Hospital, Caen, France
- UNICAEN, ISTCT/CERVOxy Group, UMR6030, GIP CYCERON, Normandy University, Caen, France
| | - Louise Deboeuf
- Service de Neurochirurgie, GHU Paris Psychiatrie et Neurosciences, Hôpital Sainte-Anne, 1, rue Cabanis, 75674, F-75014, Paris Cedex 14, France
| | - Angela Elia
- Service de Neurochirurgie, GHU Paris Psychiatrie et Neurosciences, Hôpital Sainte-Anne, 1, rue Cabanis, 75674, F-75014, Paris Cedex 14, France
- Institute of Psychiatry and Neuroscience of Paris (IPNP), INSERM U1266, IMA-BRAIN, Université Paris Cité, 75014, Paris, France
| | - Oumaima Aboubakr
- Service de Neurochirurgie, GHU Paris Psychiatrie et Neurosciences, Hôpital Sainte-Anne, 1, rue Cabanis, 75674, F-75014, Paris Cedex 14, France
| | - Martin Planet
- Service de Neurochirurgie, GHU Paris Psychiatrie et Neurosciences, Hôpital Sainte-Anne, 1, rue Cabanis, 75674, F-75014, Paris Cedex 14, France
| | - Aziz Bedioui
- Service de Neurochirurgie, GHU Paris Psychiatrie et Neurosciences, Hôpital Sainte-Anne, 1, rue Cabanis, 75674, F-75014, Paris Cedex 14, France
| | - Fréderick Rault
- Department of Neurosurgery, Caen University Hospital, Caen, France
| | - Maxime Faisant
- Department of Anatomopathology, Caen University Hospital, Caen, France
| | - Alexandre Roux
- Service de Neurochirurgie, GHU Paris Psychiatrie et Neurosciences, Hôpital Sainte-Anne, 1, rue Cabanis, 75674, F-75014, Paris Cedex 14, France
- Institute of Psychiatry and Neuroscience of Paris (IPNP), INSERM U1266, IMA-BRAIN, Université Paris Cité, 75014, Paris, France
| | - Giorgia Antonia Simboli
- Service de Neurochirurgie, GHU Paris Psychiatrie et Neurosciences, Hôpital Sainte-Anne, 1, rue Cabanis, 75674, F-75014, Paris Cedex 14, France
- Institute of Psychiatry and Neuroscience of Paris (IPNP), INSERM U1266, IMA-BRAIN, Université Paris Cité, 75014, Paris, France
| | - Alessandro Moiraghi
- Service de Neurochirurgie, GHU Paris Psychiatrie et Neurosciences, Hôpital Sainte-Anne, 1, rue Cabanis, 75674, F-75014, Paris Cedex 14, France
- Institute of Psychiatry and Neuroscience of Paris (IPNP), INSERM U1266, IMA-BRAIN, Université Paris Cité, 75014, Paris, France
| | - Thomas Gaberel
- Department of Neurosurgery, Caen University Hospital, Caen, France
- UNICAEN, INSERM, U1237, PhIND "Physiopathology and Imaging of Neurological Disorders," Institut Blood and Brain @ Caen-Normandie, Normandie University, Cyceron, Caen, France
| | - Johan Pallud
- Service de Neurochirurgie, GHU Paris Psychiatrie et Neurosciences, Hôpital Sainte-Anne, 1, rue Cabanis, 75674, F-75014, Paris Cedex 14, France
- Institute of Psychiatry and Neuroscience of Paris (IPNP), INSERM U1266, IMA-BRAIN, Université Paris Cité, 75014, Paris, France
| | - Evelyne Emery
- Department of Neurosurgery, Caen University Hospital, Caen, France
- UNICAEN, INSERM, U1237, PhIND "Physiopathology and Imaging of Neurological Disorders," Institut Blood and Brain @ Caen-Normandie, Normandie University, Cyceron, Caen, France
| | - Marc Zanello
- Service de Neurochirurgie, GHU Paris Psychiatrie et Neurosciences, Hôpital Sainte-Anne, 1, rue Cabanis, 75674, F-75014, Paris Cedex 14, France.
- Institute of Psychiatry and Neuroscience of Paris (IPNP), INSERM U1266, IMA-BRAIN, Université Paris Cité, 75014, Paris, France.
| |
Collapse
|
2
|
van Baarsen KM, Woodley DEA, Slot KM, Woerdeman PA, Han KS, Hoving EW. Robotic alignment system Cirq (Brainlab) for navigated brain tumor biopsies in children. Childs Nerv Syst 2024; 40:99-108. [PMID: 37436473 DOI: 10.1007/s00381-023-06060-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Accepted: 06/28/2023] [Indexed: 07/13/2023]
Abstract
INTRODUCTION The Cirq robotic alignment system (Brainlab, Munich, Germany) is a manually adjustable electronic arm with a robotic alignment module on its distal end, enabling the neurosurgeon to automatically and accurately align surgical instruments to a preoperatively planned trajectory. In this study, we share our first experiences and results using Cirq for intracranial tumor biopsy in children. METHODS From May 2021 until October 2022, all consecutive patients that underwent a brain tumor biopsy using Cirq were included and compared to a historical cohort of patients biopsied with the non-robotic system Varioguide (Brainlab, Munich, Germany). Patient-related data, tumor-related data, and surgery-related data were collected. Registration accuracy was calculated for different patient-to-image registration methods. Pre- and postoperative images were fused, and entry error, target error, and angulation error were calculated. RESULTS Thirty-seven patients, aged 1-19 years, were included (14 with Cirq and 23 with Varioguide). An integrated histopathological and molecular diagnosis was acquired in all cases. Patient-to-image registration was significantly more accurate when based on bone screw fiducials combined with intraoperative CT, as compared to surface matching or skin fiducials. The target error (Euclidian distance) was 5.3 mm for Cirq as compared to 8.3 mm for Varioguide, but this was not statistically significant. Entry error and angulation error were also not significantly different between both groups. CONCLUSION Intracranial biopsy with the Cirq robotic system is feasible and safe, and its accuracy does not differ from the Varioguide system.
Collapse
Affiliation(s)
- Kirsten M van Baarsen
- Department of Neuro-Oncology, Princess Máxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS, Utrecht, The Netherlands.
- Department of Pediatric Neurosurgery, Utrecht University Medical Center/Wilhelmina Children's Hospital, Utrecht, The Netherlands.
| | - Darwin E A Woodley
- Department of Neuro-Oncology, Princess Máxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS, Utrecht, The Netherlands
- Department of Pediatric Neurosurgery, Utrecht University Medical Center/Wilhelmina Children's Hospital, Utrecht, The Netherlands
| | - K Mariam Slot
- Department of Neurosurgery, Amsterdam University Medical Centers, Amsterdam, The Netherlands
| | - Peter A Woerdeman
- Department of Neuro-Oncology, Princess Máxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS, Utrecht, The Netherlands
- Department of Pediatric Neurosurgery, Utrecht University Medical Center/Wilhelmina Children's Hospital, Utrecht, The Netherlands
| | - Kuo S Han
- Department of Neuro-Oncology, Princess Máxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS, Utrecht, The Netherlands
- Department of Pediatric Neurosurgery, Utrecht University Medical Center/Wilhelmina Children's Hospital, Utrecht, The Netherlands
| | - Eelco W Hoving
- Department of Neuro-Oncology, Princess Máxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS, Utrecht, The Netherlands
- Department of Pediatric Neurosurgery, Utrecht University Medical Center/Wilhelmina Children's Hospital, Utrecht, The Netherlands
| |
Collapse
|
3
|
Kreatsoulas DC, Vignolles-Jeong J, Ambreen Y, Damante M, Akhter A, Lonser RR, Elder JB. Surgical Characteristics of Intracranial Biopsy Using a Frameless Stereotactic Robotic Platform: A Single-Center Experience. Oper Neurosurg (Hagerstown) 2023:01787389-990000000-00966. [PMID: 37976149 DOI: 10.1227/ons.0000000000000999] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 10/04/2023] [Indexed: 11/19/2023] Open
Abstract
BACKGROUND AND OBJECTIVES Cranial robotics are a burgeoning field of neurosurgery. To date, all cranial robotic systems described have been computerized, arm-based instruments that take up significant space in the operating room. The Medtronic Stealth Autoguide robot has a smaller operating room footprint and offers multiaxial, frame-based surgical targeting. The authors set out to define the surgical characteristics of a novel robotic platform for brain biopsy in a large patient cohort. METHODS Patients who underwent stereotactic biopsy using the Stealth Autoguide cranial robotic platform from July 2020 to March 2023 were included in this study. Clinical, surgical, and histological data were collected and analyzed. RESULTS Ninety-six consecutive patients (50 female, 46 male) were included. The mean age at biopsy was 53.7 ± 18.0 years. The mean target depth was 68.2 ± 15.3 mm. The biopsy diagnostic tissue acquisition rate was 100%. The mean time from incision to biopsy tissue acquisition was 15.4 ± 9.9 minutes. Target lesions were located throughout the brain: in the frontal lobe (n = 32, 33.3%), parietal lobe (n = 21, 21.9%), temporal lobe (n = 22, 22.9%), deep brain nuclei/thalamus (n = 13, 13.5%), cerebellum (n = 7, 7.3%), and brainstem (n = 1, 1.0%). Most cases were gliomas (n = 75, 78.2%). Patients were discharged home on postoperative day 0 or 1 in 62.5% of cases. A total of 7 patients developed postoperative complications (7.2%). CONCLUSION This cranial robotic platform can be used for efficient, safe, and accurate cranial biopsies that allow for reliable diagnosis of intracranial pathology in a minimally invasive setting.
Collapse
Affiliation(s)
- Daniel C Kreatsoulas
- Department of Neurological Surgery, The Ohio State University Wexner Medical Center, The Ohio State University, Columbus, Ohio, USA
| | - Joshua Vignolles-Jeong
- The Ohio State University College of Medicine, The Ohio State University, Columbus, Ohio, USA
| | - Yamenah Ambreen
- The Ohio State University College of Medicine, The Ohio State University, Columbus, Ohio, USA
| | - Mark Damante
- Department of Neurological Surgery, The Ohio State University Wexner Medical Center, The Ohio State University, Columbus, Ohio, USA
| | - Asad Akhter
- Department of Neurological Surgery, The Ohio State University Wexner Medical Center, The Ohio State University, Columbus, Ohio, USA
| | - Russell R Lonser
- Department of Neurological Surgery, The Ohio State University Wexner Medical Center, The Ohio State University, Columbus, Ohio, USA
| | - J Bradley Elder
- Department of Neurological Surgery, The Ohio State University Wexner Medical Center, The Ohio State University, Columbus, Ohio, USA
| |
Collapse
|
4
|
A Comparison of the Safety, Efficacy, and Accuracy of Frame-Based versus Remebot Robot-Assisted Stereotactic Systems for Biopsy of Brainstem Tumors. Brain Sci 2023; 13:brainsci13020362. [PMID: 36831906 PMCID: PMC9954386 DOI: 10.3390/brainsci13020362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 02/06/2023] [Accepted: 02/16/2023] [Indexed: 02/22/2023] Open
Abstract
BACKGROUND Brainstem tumors are rare and extremely heterogeneous and present significant challenges in surgical treatment. Thus, biopsies often set the foundation for the diagnosis of brainstem tumors. Multimodal, image-guided, robot-assisted frameless stereotactic biopsies are increasingly popular in neurosurgery centers. This study aimed to compare the safety, efficacy, and duration of the Remebot robot-assisted (Remebot) frameless brainstem tumor biopsy versus those of frame-based stereotactic biopsy. METHOD A retrospective analysis of 33 patients with brainstem tumors who underwent stereotactic brainstem biopsies in the department of neurosurgery from January 2016 to January 2021 was conducted. The patients were divided into two groups: the Remebot group (n = 22) and the frame-based group (n = 11). The clinical characteristics, trajectory strategy, duration of procedure, diagnostic yielding, histopathological diagnosis, and postoperative complications were retrospectively analyzed and compared between the groups. RESULTS More pediatric patients performed Remebot frameless brainstem tumor biopsy than frame-based biopsy, with a mean age of 17.3 ± 18.7 vs. 32.8 ± 17.1 (p = 0.027). The diagnostic yield had no significant difference in the two groups, with the diagnostic yield of frame-based biopsy and Remebot frameless brain biopsy being 90.9% and 95.5%, respectively. The time of the total process was 124.5 min for the frame-based biopsy and 84.7 min for the Remebot frameless brain biopsy (p < 0.001). There were no significant differences with respect to the occurrence of complication or the duration of the operation between the two groups. CONCLUSION Remebot frameless stereotactic brainstem biopsy is as safe and efficacious as frame-based stereotactic biopsy. However, Remebot frameless biopsy can reduce the total duration of the procedure and has better application in young pediatric patients. Remebot frameless stereotactic biopsies can be a better option towards the safe and efficient treatment of brainstem tumors.
Collapse
|
5
|
Dong FY, Zhan Q, Shao ZK, Gu Q, Gao XT, Zhou B, Li L, Ma YW, Wang XF, Liang YC. Clinical study on the treatment of primary trigeminal neuralgia by robot-assisted percutaneous balloon compression. Front Surg 2022; 9:1007818. [DOI: 10.3389/fsurg.2022.1007818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Accepted: 08/23/2022] [Indexed: 11/13/2022] Open
Abstract
BackgroundC-arm-guided percutaneous puncture balloon compression alone has risk factors of puncture failure, complications, and poor prognosis. Robot-assisted PBC can effectively increase the one-time puncture success rate and improve the safety of the procedure. However, evidence on the superiority of robot-assisted PBC over C-arm-guided PBC alone remains relatively limited.MethodsRetrospective analysis The clinical data of 60 patients with trigeminal neuralgia aged 60 years or older in the Department of Neurosurgery of the Fourth Hospital of Harbin Medical University from January 2021 to October 2021. There were 29 males and 31 females, and the patients’ ages ranged from 60 to 79 years, with an average of 71.63 ± 5.12 years. Two groups were divided according to the surgical method, the C-arm guidance-only group (30 cases, n = 30) and the robot-assisted group (30 cases, n = 30). The success rate of first puncture, total operation time, number of “pear-shaped” balloons, number of C-arm x-ray scans, and immediate postoperative relief rate were recorded in both groups, and follow-up was performed to evaluate the postoperative results and complications. The overall evaluation of postoperative results and complications was performed.ResultsIntraoperative balloon compression was successfully completed in all 60 patients, and the first puncture success rate was higher in the robot-assisted group than in the simple C-arm group, with a significant difference between the two groups (P < 0.001). In terms of intraoperative balloon morphology, the number of “pear-shaped” balloons was higher in the PBC than in the C-arm-only PBC group, with a significant difference between the two groups (P < 0.005). The degree of immediate postoperative remission in the robotic group was 0 VAS score, which was not statistically significant in both groups (P > 0.05). By the final follow-up, the mean VAS score of the robot-assisted group was lower than that of the simple C-arm group, and both were statistically significant (P < 0.05); complications of masticatory muscle weakness or abnormal facial sensation occurred in both groups after surgery, but the number of cases in the robot-assisted group was less than that of the simple C-arm group.ConclusionRobot-assisted PBC is better than PBC with a C-arm x-ray machine in terms of first puncture success rate, number of intraoperative balloon “pear-shaped” cases, number of C-arm x-ray scans and short-term efficacy.
Collapse
|
6
|
Minchev G, Wurzer A, Ptacek W, Kronreif G, Micko A, Dorfer C, Wolfsberger S. Development of a miniaturized robotic guidance device for stereotactic neurosurgery. J Neurosurg 2022; 137:479-488. [PMID: 34920429 DOI: 10.3171/2021.9.jns21794] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Accepted: 09/07/2021] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Consistently high accuracy and a straightforward use of stereotactic guidance systems are crucial for precise stereotactic targeting and a short procedural duration. Although robotic guidance systems are widely used, currently available systems do not fully meet the requirements for a stereotactic guidance system that combines the advantages of frameless surgery and robotic technology. The authors developed and optimized a small-scale yet highly accurate guidance system that can be seamlessly integrated into an existing operating room (OR) setup due to its design. The aim of this clinical study is to outline the development of this miniature robotic guidance system and present the authors' clinical experience. METHODS After extensive preclinical testing of the robotic stereotactic guidance system, adaptations were implemented for robot fixation, software usability, navigation integration, and end-effector application. Development of the robotic system was then advanced in a clinical series of 150 patients between 2013 and 2019, including 111 needle biopsies, 13 catheter placements, and 26 stereoelectroencephalography (SEEG) electrode placements. During the clinical trial, constant modifications were implemented to meet the setup requirements, technical specifications, and workflow for each indication. For each application, specific setup, workflow, and median procedural accuracy were evaluated. RESULTS Application of the miniature robotic system was feasible in 149 of 150 cases. The setup in each procedure was successfully implemented without adding significant OR time. The workflow was seamlessly integrated into the preexisting procedure. In the course of the study, procedural accuracy was improved. For the biopsy procedure, the real target error (RTE) was reduced from a mean of 1.8 ± 1.03 mm to 1.6 ± 0.82 mm at entry (p = 0.05), and from 1.7 ± 1.12 mm to 1.6 ± 0.72 mm at target (p = 0.04). For the SEEG procedures, the RTE was reduced from a mean of 1.43 ± 0.78 mm in the first half of the procedures to 1.12 ± 0.52 mm (p = 0.002) at entry in the second half, and from 1.82 ± 1.13 mm to 1.57 ± 0.98 mm (p = 0.069) at target, respectively. No healing complications or infections were observed in any case. CONCLUSIONS The miniature robotic guidance device was able to prove its versatility and seamless integration into preexisting workflow by successful application in 149 stereotactic procedures. According to these data, the robot could significantly improve accuracy without adding time expenditure.
Collapse
Affiliation(s)
- Georgi Minchev
- 1Department of Neurosurgery, Medical University Vienna; and
| | - Ayguel Wurzer
- 1Department of Neurosurgery, Medical University Vienna; and
| | - Wolfgang Ptacek
- 2Austrian Center for Medical Innovation and Technology (ACMIT), Wiener Neustadt, Austria
| | - Gernot Kronreif
- 2Austrian Center for Medical Innovation and Technology (ACMIT), Wiener Neustadt, Austria
| | | | | | | |
Collapse
|
7
|
Hu Y, Cai P, Zhang H, Adilijiang A, Peng J, Li Y, Che S, Lan F, Liu C. A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy. Front Neurol 2022; 13:928070. [PMID: 35923834 PMCID: PMC9339900 DOI: 10.3389/fneur.2022.928070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 06/22/2022] [Indexed: 11/13/2022] Open
Abstract
Introduction Frame-based stereotactic biopsy is well-established to play an essential role in neurosurgery. In recent years, different robotic devices have been introduced in neurosurgery centers. This study aimed to compare the SINO surgical robot-assisted frameless brain biopsy with standard frame-based stereotactic biopsy in terms of efficacy, accuracy and complications. Methods A retrospective analysis was performed on 151 consecutive patients who underwent stereotactic biopsy at Chongqing Sanbo Jiangling Hospital between August 2017 and December 2021. All patients were divided into the frame-based group (n = 47) and the SINO surgical robot-assisted group (n = 104). The data collected included clinical characteristics, diagnostic yield, operation times, accuracy, and postoperative complications. Results There was no significant difference in diagnostic yield between the frame-based group and the SINO surgical robot-assisted group (95.74 vs. 98.08%, p > 0.05). The mean operation time in the SINO surgical robot-assisted group was significantly shorter than in the frame-based group (29.36 ± 13.64 vs. 50.57 ± 41.08 min). The entry point error in the frame-based group was significantly higher than in the robot-assisted group [1.33 ± 0.40 mm (0.47–2.30) vs. 0.92 ± 0.27 mm (0.35–1.65), P < 0.001]. The target point error in the frame-based group was also significantly higher than in the robot-assisted group [1.63 ± 0.41 mm (0.74–2.65) vs. 1.10 ± 0.30 mm (0.69–2.03), P < 0.001]. Finally, there was no significant difference in postoperative complications between the two groups. Conclusion Robot-assisted brain biopsy becomes an increasingly mainstream tool in the neurosurgical procedure. The SINO surgical robot-assisted platform is as efficient, accurate and safe as standard frame-based stereotactic biopsy and provides a reasonable alternative to stereotactic biopsy in neurosurgery.
Collapse
Affiliation(s)
- Yue Hu
- Department of Neurosurgery, Sanbo Brain Hospital, Capital Medical University, Beijing, China
| | - Pu Cai
- Department of Neurosurgery, Chongqing Sanbo Jiangling Hospital, Chongqing, China
| | - Huawei Zhang
- Department of Neurosurgery, Sanbo Brain Hospital, Capital Medical University, Beijing, China
| | | | - Jun Peng
- Department of Neurosurgery, Chongqing Sanbo Jiangling Hospital, Chongqing, China
| | - Yun Li
- Department of Neurosurgery, Chongqing Sanbo Jiangling Hospital, Chongqing, China
| | - Shanli Che
- Department of Neurosurgery, Chongqing Sanbo Jiangling Hospital, Chongqing, China
| | - Fei Lan
- Department of Neurosurgery, Chongqing Sanbo Jiangling Hospital, Chongqing, China
| | - Changqing Liu
- Department of Neurosurgery, Sanbo Brain Hospital, Capital Medical University, Beijing, China
- Department of Neurosurgery, Chongqing Sanbo Jiangling Hospital, Chongqing, China
- Center of Epilepsy, Beijing Institute for Brain Disorders, Beijing, China
- *Correspondence: Changqing Liu
| |
Collapse
|
8
|
Katzendobler S, Do A, Weller J, Dorostkar MM, Albert NL, Forbrig R, Niyazi M, Egensperger R, Thon N, Tonn JC, Quach S. Diagnostic Yield and Complication Rate of Stereotactic Biopsies in Precision Medicine of Gliomas. Front Neurol 2022; 13:822362. [PMID: 35432168 PMCID: PMC9005817 DOI: 10.3389/fneur.2022.822362] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Accepted: 02/23/2022] [Indexed: 12/27/2022] Open
Abstract
BackgroundAn integrated diagnosis consisting of histology and molecular markers is the basis of the current WHO classification system of gliomas. In patients with suspected newly diagnosed or recurrent glioma, stereotactic biopsy is an alternative in cases in which microsurgical resection is deemed to not be safely feasible or indicated. In this retrospective study, we aimed to analyze both the diagnostic yield and the safety of a standardized biopsy technique.Material and MethodsThe institutional database was screened for frame-based biopsy procedures (January 2016 until March 2021). Only patients with a suspected diagnosis of glioma based on imaging were included. All tumors were classified according to the current WHO grading system. The clinical parameters, procedural complications, histology, and molecular signature of the tissues obtained were assessed.ResultsBetween January 2016 and March 2021, 1,214 patients underwent a stereotactic biopsy: 617 (50.8%) for a newly diagnosed lesion and 597 (49.2%) for a suspected recurrence. The median age was 56.9 years (range 5 months−94.4 years). Magnetic resonance imaging (MRI)-guidance was used in 99.3% of cases and additional positron emission tomography (PET)-guidance in 34.3% of cases. In total, stereotactic serial biopsy provided an integrated diagnosis in 96.3% of all procedures. The most frequent diagnoses were isocitrate dehydrogenase (IDH) wildtype glioblastoma (n = 596; 49.2%), oligodendroglioma grade 2 (n = 109; 9%), astrocytoma grade 3 (n = 108; 8.9%), oligodendroglioma grade 3 (n = 76; 6.3%), and astrocytoma grade 2 (n = 66; 5.4%). A detailed determination was successful for IDH 1/2 mutation in 99.4% of cases, for 1p/19q codeletion in 97.4% of cases, for TERT mutation in 98.9% of cases, and for MGMT promoter methylation in 99.1% of cases. Next-generation sequencing was evaluable in 64/67 (95.5%) of cases and DNA methylome analysis in 41/44 (93.2%) of cases. Thirteen (1.1%) cases showed glial tumors that could not be further specified. Seventy-three tumors were different non-glioma entities, e.g., of infectious or inflammatory nature. Seventy-five out of 597 suspected recurrences turned out to be post-therapeutic changes only. The rate of post-procedural complications with clinical symptoms of the Common Terminology Criteria for Adverse Events (CTCAE) grade 3 or higher was 1.2% in overall patients and 2.6% in the subgroup of brainstem biopsies. There was no fatal outcome in the entire series.ConclusionImage-guided stereotactic serial biopsy enables obtaining reliable histopathological and molecular diagnoses with a very low complication rate even in tumors with critical localization. Thus, in patients not undergoing microsurgical resection, this is a valuable tool for precision medicine of patients with glioma.
Collapse
Affiliation(s)
- Sophie Katzendobler
- Department of Neurosurgery, University Hospital, LMU Munich, Munich, Germany
| | - Anna Do
- Department of Neurosurgery, University Hospital, LMU Munich, Munich, Germany
| | - Jonathan Weller
- Department of Neurosurgery, University Hospital, LMU Munich, Munich, Germany
| | - Mario M. Dorostkar
- Center for Neuropathology and Prion Research, LMU Munich, Munich, Germany
| | - Nathalie L. Albert
- Department of Nuclear Medicine, University Hospital, LMU Munich, Munich, Germany
- German Cancer Consortium (DKTK), Partner Site Munich, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Robert Forbrig
- Institute of Neuroradiology, University Hospital, LMU Munich, Munich, Germany
| | - Maximilian Niyazi
- German Cancer Consortium (DKTK), Partner Site Munich, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Rupert Egensperger
- Center for Neuropathology and Prion Research, LMU Munich, Munich, Germany
| | - Niklas Thon
- Department of Neurosurgery, University Hospital, LMU Munich, Munich, Germany
| | - Joerg Christian Tonn
- Department of Neurosurgery, University Hospital, LMU Munich, Munich, Germany
- German Cancer Consortium (DKTK), Partner Site Munich, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Stefanie Quach
- Department of Neurosurgery, University Hospital, LMU Munich, Munich, Germany
- *Correspondence: Stefanie Quach
| |
Collapse
|
9
|
Mallereau CH, Chibbaro S, Ganau M, Benmekhbi M, Cebula H, Dannhoff G, Santin MDN, Ollivier I, Chaussemy D, Hugo Coca A, Proust F, Todeschi J. Pushing the boundaries of accuracy and reliability during stereotactic procedures: A prospective study on 526 biopsies comparing the frameless robotic and Image-Guided Surgery systems. J Clin Neurosci 2021; 95:203-212. [PMID: 34933231 DOI: 10.1016/j.jocn.2021.11.034] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Revised: 11/10/2021] [Accepted: 11/27/2021] [Indexed: 01/13/2023]
Abstract
INTRODUCTION A 12-year long, prospective, single center study was conducted, comparing two frameless systems for brain biopsies: ROSA robotic-assisted stereotaxy and BrainLab Varioguide image-guided stereotaxy (Image Guided Surgery, IGS). METHOD All consecutive adult and pediatric patients undergoing frameless brain biopsies were included. Successfully achieving diagnosis was the primary endpoint, analysis of all periprocedural complications was the secondary endpoint, and the tertiary endpoint was the length of the procedure, with the aim of assessing of the learning curve for each operator over time. The results for the ROSA robot and the Varioguide system were compared and benchmarked to data from the literature. RESULTS We performed 526 on 516 patients, 314 with the ROSA robot (Group A) and 212 with the IGS Varioguide (Group B). Histological diagnosis was achieved in 97.4% of cases in Group A, versus 93.3% in Group B (p < 0.05). No statistically significant difference was found for secondary and tertiary endpoints. The complication rate appeared similar between the 2 frameless systems, with a hemorrhagic complications rate of 3.5% in Group A and 4.7% in Group B. Permanent neurological deterioration was only recorded in 0.8% of cases from Group B. Mortality was recorded in 0.3% in Group A and 0.4% in Group B. CONCLUSION This study provides evidence to confirm that robotic surgery lives up to its promises of increased safety, accuracy, and reliability.
Collapse
Affiliation(s)
| | - Salvatore Chibbaro
- Department of Neurosurgery, Strasbourg University Hospital, Strasbourg, France
| | - Mario Ganau
- Department of Neurosurgery, Strasbourg University Hospital, Strasbourg, France
| | - Mustapha Benmekhbi
- Department of Neurosurgery, Strasbourg University Hospital, Strasbourg, France
| | - Helene Cebula
- Department of Neurosurgery, Strasbourg University Hospital, Strasbourg, France
| | - Guillaume Dannhoff
- Department of Neurosurgery, Strasbourg University Hospital, Strasbourg, France
| | | | - Irène Ollivier
- Department of Neurosurgery, Strasbourg University Hospital, Strasbourg, France
| | - Dominique Chaussemy
- Department of Neurosurgery, Strasbourg University Hospital, Strasbourg, France
| | - Andres Hugo Coca
- Department of Neurosurgery, Strasbourg University Hospital, Strasbourg, France
| | - François Proust
- Department of Neurosurgery, Strasbourg University Hospital, Strasbourg, France
| | - Julien Todeschi
- Department of Neurosurgery, Strasbourg University Hospital, Strasbourg, France
| |
Collapse
|
10
|
Koizumi S, Shiraishi Y, Makita I, Kadowaki M, Sameshima T, Kurozumi K. A novel technique for fence-post tube placement in glioma using the robot-guided frameless neuronavigation technique under exoscope surgery: patient series. JOURNAL OF NEUROSURGERY: CASE LESSONS 2021; 2:CASE21466. [PMID: 35855488 PMCID: PMC9281438 DOI: 10.3171/case21466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Accepted: 10/22/2021] [Indexed: 11/18/2022]
Abstract
BACKGROUND Robotic technology is increasingly used in neurosurgery. The authors reported a new technique for fence-post tube placement using robot-guided frameless stereotaxic technology with neuronavigation in patients with glioma. OBSERVATIONS Surgery was performed using the StealthStation S8 linked to the Stealth Autoguide cranial robotic guidance platform and a high-resolution three-dimensional (3D) surgical microscope. A surgical plan was created to determine the removal area using fence-post tube placement at the tumor and normal brain tissue boundary. Using this surgical plan, the robotic system allowed quick and accurate fence-post tube positioning, automatic alignment of the needle insertion and measurement positions in the brain, and quick and accurate puncture needle insertion into the brain tumor. Use of a ventricular drainage tube for the outer needle cylinder allowed placement of the puncture needle in a single operation. Furthermore, use of a high-resolution 3D exoscope allowed the surgeon to simultaneously view the surgical field image and the navigation screen with minimal line-of-sight movement, which improved operative safety. The position memory function of the 3D exoscope allowed easy switching between the exoscope and the microscope and optimal field of view adjustment. LESSONS Fence-post tube placement using robot-guided frameless stereotaxic technology, neuronavigation, and an exoscope allows precise glioma resection.
Collapse
Affiliation(s)
- Shinichiro Koizumi
- Department of Neurosurgery, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| | - Yuki Shiraishi
- Department of Neurosurgery, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| | - Ippei Makita
- Department of Neurosurgery, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| | - Makoto Kadowaki
- Department of Neurosurgery, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| | - Tetsuro Sameshima
- Department of Neurosurgery, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| | - Kazuhiko Kurozumi
- Department of Neurosurgery, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| |
Collapse
|
11
|
Reassessing the Role of Brain Tumor Biopsy in the Era of Advanced Surgical, Molecular, and Imaging Techniques-A Single-Center Experience with Long-Term Follow-Up. J Pers Med 2021; 11:jpm11090909. [PMID: 34575685 PMCID: PMC8472374 DOI: 10.3390/jpm11090909] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Revised: 09/06/2021] [Accepted: 09/09/2021] [Indexed: 01/11/2023] Open
Abstract
Brain biopsy is the gold standard in order to establish the diagnosis of unresectable brain tumors. Few studies have investigated the long-term outcomes of biopsy patients. The aim of this single-institution-based study was to assess the concordance between radiological and histopathological diagnoses, and the long-term patient outcome. Ninety-three patients who underwent brain biopsy in the last 5 years were analyzed. We included patients treated with stereotactically guided needle, open, and neuroendoscopic biopsies. Most patients (86%) received needle biopsy. Gliomas and primary brain lymphomas comprised 88.2% of cases. The diagnostic yield was 95.7%. Serious complication and death rates were 3.2% and 2.1%, respectively. The concordance rate between radiological and histological diagnoses was 93%. Notably, the positive predictive value of radiological diagnosis of lymphoma was 100%. Biopsy allowed specific treatment in 72% of cases. Disease-related neurological worsening was the main reason that precluded adjuvant treatment. Adjuvant treatment, in turn, was the strongest prognostic factor, since the median overall survival was 11 months with vs. 2 months without treatment (p = 0.0002). Finally, advanced molecular evaluations can be obtained on glioma biopsy specimens to provide integrated diagnoses and individually tailored treatments. We conclude that, despite the huge advances in imaging techniques, biopsy is required when an adjuvant treatment is recommended, particularly in gliomas.
Collapse
|
12
|
Liu HG, Liu YY, Zhang H, Meng FG, Zhang K, Zhu GY, Chen YC, Liu DF, Zhang JG, Yang AC. A Bulk Retrospective Study of Robot-Assisted Stereotactic Biopsies of Intracranial Lesions Guided by Videometric Tracker. Front Neurol 2021; 12:682733. [PMID: 34421791 PMCID: PMC8371178 DOI: 10.3389/fneur.2021.682733] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Accepted: 06/30/2021] [Indexed: 11/13/2022] Open
Abstract
Background: Biopsies play an important role in the diagnosis of intracranial lesions, and robot-assisted procedures are increasingly common in neurosurgery centers. This research investigates the diagnoses, complications, and technology yield of 700 robotic frameless intracranial stereotactic biopsies conducted with the Remebot system. Method: This research considered 700 robotic biopsies performed between 2016 and 2020 by surgeons from the Department of Functional Neurosurgery in Beijing's Tiantan Hospital. The data collected included histological diagnoses, postoperative complications, operation times, and the accuracy of robotic manipulation. Results: Among the 700 surgeries, the positive rate of the biopsies was 98.2%. The most common histological diagnoses were gliomas, which accounted for 62.7% of cases (439/700), followed by lymphoma and germinoma, which accounted for 18.7% (131/700) and 7.6% (53/700). Bleeding was found in 14 patients (2%) by post-operation computed tomography scans. A total of 29 (4.14%) patients had clinical impairments after the operation, and 9 (1.29%) experienced epilepsy during the operation. The post-biopsy mortality rate was 0.43%. Operation time-from marking the cranial point to suturing the skin-was 16.78 ± 3.31 min (range 12-26 min). The target error was 1.13 ± 0.30 mm, and the entry point error was 0.99 ± 0.24 mm. Conclusion: A robot-assisted frameless intracranial stereotactic biopsy guided by a videometric tracker is an efficient, safe, and accurate method for biopsies.
Collapse
Affiliation(s)
- Huan-Guang Liu
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Yu-Ye Liu
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Hua Zhang
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Fan-Gang Meng
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.,Department of Functional Neurosurgery, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
| | - Kai Zhang
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Guan-Yu Zhu
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Ying-Chuan Chen
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - De-Feng Liu
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Jian-Guo Zhang
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.,Department of Functional Neurosurgery, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China.,Key Laboratory of Computational Neuroscience and Brain-Inspired Intelligence (Fudan University), Ministry of Education, Beijing, China
| | - An-Chao Yang
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
13
|
Rubino F, Eichberg DG, Cordeiro JG, Di L, Eliahu K, Shah AH, Luther EM, Lu VM, Komotar RJ, Ivan ME. Robotic guidance platform for laser interstitial thermal ablation and stereotactic needle biopsies: a single center experience. J Robot Surg 2021; 16:549-557. [PMID: 34258748 PMCID: PMC8276839 DOI: 10.1007/s11701-021-01278-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 07/04/2021] [Indexed: 11/28/2022]
Abstract
While laser ablation has become an increasingly important tool in the neurosurgical oncologist's armamentarium, deep seated lesions, and those located near critical structures require utmost accuracy during stereotactic laser catheter placement. Robotic devices have evolved significantly over the past two decades becoming an accurate and safe tool for stereotactic neurosurgery. Here, we present our single center experience with the MedTech ROSA ONE Brain robot for robotic guidance in laser interstitial thermal therapy (LITT) and stereotactic biopsies. We retrospectively analyzed the first 70 consecutive patients treated with ROSA device at a single academic medical center. Forty-three patients received needle biopsy immediately followed by LITT with the catheter placed with robotic guidance and 27 received stereotactic needle biopsy alone. All the procedures were performed frameless with skull bone fiducials for registration. We report data regarding intraoperative details, mortality and morbidity, diagnostic yield and lesion characteristics on MRI. Also, we describe the surgical workflow for both procedures. The mean age was 60.3 ± 15 years. The diagnostic yield was positive in 98.5% (n = 69). Sixty-three biopsies (90%) were supratentorial and seven (10%) were infratentorial. Gliomas represented 54.3% of the patients (n = 38). There were two postoperative deaths (2.8%). No permanent morbidity related to surgery were observed. We did not find intraoperative technical problems with the device. There was no need to reposition the needle after the initial placement. Stereotactic robotic guided placement of laser ablation catheters and biopsy needles is safe, accurate, and can be implemented into a neurosurgical workflow.
Collapse
Affiliation(s)
- Franco Rubino
- Department of Neurological Surgery, University of Miami Miller School of Medicine, Lois Pope Life Center, 1095 NW 14th Terrace (D4-6), Miami, FL, 33146, USA.
| | - Daniel G Eichberg
- Department of Neurological Surgery, University of Miami Miller School of Medicine, Lois Pope Life Center, 1095 NW 14th Terrace (D4-6), Miami, FL, 33146, USA
| | - Joacir G Cordeiro
- Department of Neurological Surgery, University of Miami Miller School of Medicine, Lois Pope Life Center, 1095 NW 14th Terrace (D4-6), Miami, FL, 33146, USA
| | - Long Di
- Department of Neurological Surgery, University of Miami Miller School of Medicine, Lois Pope Life Center, 1095 NW 14th Terrace (D4-6), Miami, FL, 33146, USA
| | - Karen Eliahu
- Department of Neurological Surgery, University of Miami Miller School of Medicine, Lois Pope Life Center, 1095 NW 14th Terrace (D4-6), Miami, FL, 33146, USA
| | - Ashish H Shah
- Department of Neurological Surgery, University of Miami Miller School of Medicine, Lois Pope Life Center, 1095 NW 14th Terrace (D4-6), Miami, FL, 33146, USA
| | - Evan M Luther
- Department of Neurological Surgery, University of Miami Miller School of Medicine, Lois Pope Life Center, 1095 NW 14th Terrace (D4-6), Miami, FL, 33146, USA
| | - Victor M Lu
- Department of Neurological Surgery, University of Miami Miller School of Medicine, Lois Pope Life Center, 1095 NW 14th Terrace (D4-6), Miami, FL, 33146, USA
| | - Ricardo J Komotar
- Department of Neurological Surgery, University of Miami Miller School of Medicine, Lois Pope Life Center, 1095 NW 14th Terrace (D4-6), Miami, FL, 33146, USA.,Sylvester Comprehensive Cancer Center, Miami, FL, 33146, USA
| | - Michael E Ivan
- Department of Neurological Surgery, University of Miami Miller School of Medicine, Lois Pope Life Center, 1095 NW 14th Terrace (D4-6), Miami, FL, 33146, USA.,Sylvester Comprehensive Cancer Center, Miami, FL, 33146, USA
| |
Collapse
|
14
|
Machetanz K, Grimm F, Wang S, Bender B, Tatagiba M, Gharabaghi A, Naros G. Patient-to-robot registration: The fate of robot-assisted stereotaxy. Int J Med Robot 2021; 17:e2288. [PMID: 34036749 DOI: 10.1002/rcs.2288] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2021] [Revised: 05/22/2021] [Accepted: 05/22/2021] [Indexed: 11/06/2022]
Abstract
BACKGROUND Robot-assisted stereotaxy (RAS) promises higher stereotactic accuracy (SA) and time efficiency (TE) than frame-based stereotaxy. However, both aspects are attributed to the problem of patient-to-robot registration. OBJECTIVE To examine different registration techniques regarding their SA and TE. METHODS This study enrolled 57 patients undergoing RAS with bone fiducial registration (BFR) or laser surface registration (LSR). SA was measured by the entry point error (EPE). Additionally, predictors of SA (registration error [RegE], distance-to-registration plane [DTC]) and TE (imaging, skin-to-skin) were assessed. RESULTS The mean SA was 1.0 ± 0.8 mm. BFR increased SA by reducing RegE and DTC. In LSR, EPE depended on DTC (face and forehead) with highest accuracy for DTC ≤100 mm. CT-based LSR exerted a higher SA than MR-based LSR. In BFR, TE was confined by the additional imaging. CONCLUSION Every registration technique counteracts one of the promises of RAS. New solutions are needed to increase the acceptance of RAS in neurosurgery.
Collapse
Affiliation(s)
- Kathrin Machetanz
- Department of Neurosurgery and Neurotechnology, Neurosurgical Clinic, Eberhard Karls University, Tuebingen, Germany.,Department of Neurosurgery and Neurotechnology, Institute for Neuromodulation and Neurotechnology, Eberhard Karls University, Tuebingen, Germany
| | - Florian Grimm
- Department of Neurosurgery and Neurotechnology, Neurosurgical Clinic, Eberhard Karls University, Tuebingen, Germany.,Department of Neurosurgery and Neurotechnology, Institute for Neuromodulation and Neurotechnology, Eberhard Karls University, Tuebingen, Germany
| | - Sophie Wang
- Department of Neurosurgery and Neurotechnology, Neurosurgical Clinic, Eberhard Karls University, Tuebingen, Germany
| | - Benjamin Bender
- Department of Neuroradiology, Eberhard Karls University, Tuebingen, Germany
| | - Marcos Tatagiba
- Department of Neurosurgery and Neurotechnology, Neurosurgical Clinic, Eberhard Karls University, Tuebingen, Germany
| | - Alireza Gharabaghi
- Department of Neurosurgery and Neurotechnology, Institute for Neuromodulation and Neurotechnology, Eberhard Karls University, Tuebingen, Germany
| | - Georgios Naros
- Department of Neurosurgery and Neurotechnology, Neurosurgical Clinic, Eberhard Karls University, Tuebingen, Germany.,Department of Neurosurgery and Neurotechnology, Institute for Neuromodulation and Neurotechnology, Eberhard Karls University, Tuebingen, Germany
| |
Collapse
|
15
|
Rotim K, Splavski B, Vrban F. THE SAFETY AND EFFICACY OF ROBOT-ASSISTED STEREOTACTIC BIOPSY FOR BRAIN GLIOMA: EARLIEST INSTITUTIONAL EXPERIENCES AND EVALUATION OF LITERATURE. Acta Clin Croat 2021; 60:296-303. [PMID: 34744281 PMCID: PMC8564848 DOI: 10.20471/acc.2021.60.02.17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2021] [Accepted: 05/27/2021] [Indexed: 11/24/2022] Open
Abstract
Robot-assisted brain tumor biopsy is becoming one of the most important innovative technologies in neurosurgical practice. The idea behind its engagement is to advance the safety and efficacy of the biopsy procedure, which is much in demand when planning the management of endocranial tumor pathology. Herein, we provide our earliest institutional experiences in utilizing this mesmerizing technology. Cranial robotic device was employed for stereotactic robot-assisted brain glioma biopsy in three consecutive patients from our series: an anaplastic isocitrate dehydrogenase (IDH) negative astrocytoma (WHO grade III) located in the right trigone region of the periventricular white matter; a low grade diffuse astrocytoma (WHO grade II) of bilateral thalamic region spreading into the right mesencephalic area; and an IDH-wildtype glioblastoma (WHO grade IV) of the right frontal lobe producing a contralateral midline shifting. Robot-assisted tumor biopsy was successfully performed to get tissue samples for histopathologic and immunohistochemical analysis. The adjacent tissue iatrogenic damage of the eloquent cortical areas was minimal, while the immediate postoperative recovery was satisfactory in all patients. In conclusion, considering the preliminary results of our early experiences, robot-assisted tumor biopsy was proven to be a feasible and accurate procedure when surgery for brain glioma was not an option. It may increase safety and precision, without expanding surgical time, being similarly effective when compared to standard stereotactic and manual biopsy. Using this method to provide accurate sampling for histopathologic and immunohistochemical analysis is a safe and easy way to determine management strategies and outcome of different types of brain glioma.
Collapse
Affiliation(s)
| | - Bruno Splavski
- 1Department of Neurosurgery, Sestre milosrdnice University Hospital Centre, Zagreb, Croatia; 2Josip Juraj Strossmayer University of Osijek, Faculty of Medicine, Osijek, Croatia; 3University of Applied Health Sciences, Zagreb, Croatia; 4Josip Juraj Strossmayer University of Osijek, Faculty of Dental Medicine and Health, Osijek, Croatia
| | - Filip Vrban
- 1Department of Neurosurgery, Sestre milosrdnice University Hospital Centre, Zagreb, Croatia; 2Josip Juraj Strossmayer University of Osijek, Faculty of Medicine, Osijek, Croatia; 3University of Applied Health Sciences, Zagreb, Croatia; 4Josip Juraj Strossmayer University of Osijek, Faculty of Dental Medicine and Health, Osijek, Croatia
| |
Collapse
|
16
|
Le Fèvre C, Constans JM, Chambrelant I, Antoni D, Bund C, Leroy-Freschini B, Schott R, Cebula H, Noël G. Pseudoprogression versus true progression in glioblastoma patients: A multiapproach literature review. Part 2 - Radiological features and metric markers. Crit Rev Oncol Hematol 2021; 159:103230. [PMID: 33515701 DOI: 10.1016/j.critrevonc.2021.103230] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 01/10/2021] [Accepted: 01/16/2021] [Indexed: 12/28/2022] Open
Abstract
After chemoradiotherapy for glioblastoma, pseudoprogression can occur and must be distinguished from true progression to correctly manage glioblastoma treatment and follow-up. Conventional treatment response assessment is evaluated via conventional MRI (contrast-enhanced T1-weighted and T2/FLAIR), which is unreliable. The emergence of advanced MRI techniques, MR spectroscopy, and PET tracers has improved pseudoprogression diagnostic accuracy. This review presents a literature review of the different imaging techniques and potential imaging biomarkers to differentiate pseudoprogression from true progression.
Collapse
Affiliation(s)
- Clara Le Fèvre
- Department of Radiotherapy, ICANS, Institut Cancérologie Strasbourg Europe, 17 rue Albert Calmette, 67200, Strasbourg Cedex, France.
| | - Jean-Marc Constans
- Department of Radiology, Amiens-Picardie University Hospital, 1 rond-point du Professeur Christian Cabrol, 80054, Amiens Cedex 1, France.
| | - Isabelle Chambrelant
- Department of Radiotherapy, ICANS, Institut Cancérologie Strasbourg Europe, 17 rue Albert Calmette, 67200, Strasbourg Cedex, France.
| | - Delphine Antoni
- Department of Radiotherapy, ICANS, Institut Cancérologie Strasbourg Europe, 17 rue Albert Calmette, 67200, Strasbourg Cedex, France.
| | - Caroline Bund
- Department of Nuclear Medicine, ICANS, Institut Cancérologie Strasbourg Europe, 17 rue Albert Calmette, 67200, Strasbourg Cedex, France.
| | - Benjamin Leroy-Freschini
- Department of Nuclear Medicine, ICANS, Institut Cancérologie Strasbourg Europe, 17 rue Albert Calmette, 67200, Strasbourg Cedex, France.
| | - Roland Schott
- Departement of Medical Oncology, ICANS, Institut Cancérologie Strasbourg Europe, 17 rue Albert Calmette, 67200, Strasbourg Cedex, France.
| | - Hélène Cebula
- Departement of Neurosurgery, Hautepierre University Hospital, 1, avenue Molière, 67200, Strasbourg, France.
| | - Georges Noël
- Department of Radiotherapy, ICANS, Institut Cancérologie Strasbourg Europe, 17 rue Albert Calmette, 67200, Strasbourg Cedex, France.
| |
Collapse
|
17
|
Machetanz K, Grimm F, Schuhmann M, Tatagiba M, Gharabaghi A, Naros G. Time Efficiency in Stereotactic Robot-Assisted Surgery: An Appraisal of the Surgical Procedure and Surgeon's Learning Curve. Stereotact Funct Neurosurg 2020; 99:25-33. [PMID: 33017833 DOI: 10.1159/000510107] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Accepted: 07/11/2020] [Indexed: 11/19/2022]
Abstract
BACKGROUND Frame-based stereotactic procedures are still the gold standard in neurosurgery. However, there is an increasing interest in robot-assisted technologies. Introducing these increasingly complex tools in the clinical setting raises the question about the time efficiency of the system and the essential learning curve of the surgeon. METHODS This retrospective study enrolled a consecutive series of patients undergoing a robot-assisted procedure after first system installation at one institution. All procedures were performed by the same neurosurgeon to capture the learning curve. The objective read-out were the surgical procedure time (SPT), the skin-to-skin time, and the intraoperative registration time (IRT) after laser surface registration (LSR), bone fiducial registration (BFR), and skin fiducial registration (SFR), as well as the quality of the registration (as measured by the fiducial registration error [FRE]). The time measures were compared to those for a patient group undergoing classic frame-based stereotaxy. RESULTS In the first 7 months, we performed 31 robot-assisted surgeries (26 biopsies, 3 stereotactic electroencephalography [SEEG] implantations, and 2 endoscopic procedures). The SPT was depending on the actual type of surgery (biopsies: 85.0 ± 36.1 min; SEEG: 154.9 ± 75.9 min; endoscopy: 105.5 ± 1.1 min; p = 0.036). For the robot-assisted biopsies, there was a significant reduction in SPT within the evaluation period, reaching the level of frame-based surgeries (58.1 ± 17.9 min; p < 0.001). The IRT was depending on the applied registration method (LSR: 16.7 ± 2.3 min; BFR: 3.5 ± 1.1 min; SFR: 3.5 ± 1.6 min; p < 0.001). In contrast to BFR and SFR, there was a significant reduction in LSR time during that period (p = 0.038). The FRE differed between the applied registration methods (LSR: 0.60 ± 0.17 mm; BFR: 0.42 ± 0.15 mm; SFR: 2.17 ± 0.78 mm; p < 0.001). There was a significant improvement in LSR quality during the evaluation period (p = 0.035). CONCLUSION Introducing stereotactic, robot-assisted surgery in an established clinical setting initially necessitates a prolonged intraoperative preparation time. However, there is a steep learning curve during the first cases, reaching the time level of classic frame-based stereotaxy. Thus, a stereotactic robot can be integrated into daily routine within a decent period of time, thereby expanding the neurosurgeons' armamentarium, especially for procedures with multiple trajectories.
Collapse
Affiliation(s)
- Kathrin Machetanz
- Department of Neurosurgery, Eberhardt Karls University of Tübingen, Tübingen, Germany.,Division of Functional and Restorative Neurosurgery, Department of Neurosurgery, Eberhard Karls University of Tübingen, Tübingen, Germany
| | - Florian Grimm
- Department of Neurosurgery, Eberhardt Karls University of Tübingen, Tübingen, Germany.,Division of Functional and Restorative Neurosurgery, Department of Neurosurgery, Eberhard Karls University of Tübingen, Tübingen, Germany
| | - Martin Schuhmann
- Department of Neurosurgery, Eberhardt Karls University of Tübingen, Tübingen, Germany
| | - Marcos Tatagiba
- Department of Neurosurgery, Eberhardt Karls University of Tübingen, Tübingen, Germany
| | - Alireza Gharabaghi
- Department of Neurosurgery, Eberhardt Karls University of Tübingen, Tübingen, Germany.,Division of Functional and Restorative Neurosurgery, Department of Neurosurgery, Eberhard Karls University of Tübingen, Tübingen, Germany
| | - Georgios Naros
- Department of Neurosurgery, Eberhardt Karls University of Tübingen, Tübingen, Germany, .,Division of Functional and Restorative Neurosurgery, Department of Neurosurgery, Eberhard Karls University of Tübingen, Tübingen, Germany,
| |
Collapse
|
18
|
Wu S, Wang J, Gao P, Liu W, Hu F, Jiang W, Lei T, Shu K. A comparison of the efficacy, safety, and duration of frame-based and Remebot robot-assisted frameless stereotactic biopsy. Br J Neurosurg 2020; 35:319-323. [PMID: 32940070 DOI: 10.1080/02688697.2020.1812519] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVE The aim of this study was to compare the efficacy, safety, and duration of Remebot robot-assisted frameless brain biopsy with those of standard frame-based stereotactic biopsy. PATIENTS AND METHODS A retrospective analysis of 66 patients undergoing stereotactic brain biopsy in our department from January 2015 to January 2019 was performed. We divided the patients into two groups: the frame-based group (n = 35) and the Remebot robot group (n = 31). Data on clinical characteristics, total procedure length, overall discomfort, diagnostic yield, complications, and postoperative length of hospital stay were retrospectively reviewed and compared between these two groups. RESULTS No significant difference in diagnostic yield was detected in the two groups, with frame-based biopsy having a diagnostic yield of 91.4% and Remebot robot-assisted frameless brain biopsy having a diagnostic yield of 93.5%. The duration of the total procedure was 116.5 min for the frame-based biopsy and 80.1 min for the Remebot robot-assisted frameless brain biopsy (p < 0.001). There were no statistically significant differences in complication rate or postoperative duration of hospitalization between the two groups. The overall patient discomfort in the frame-based group was significantly greater than that in the Remebot robot group (visual analog scale score 2.7 ± 1.2 versus 1.5 ± 0.7, p = 0.001). CONCLUSIONS Remebot robot-assisted frameless brain biopsy was as efficacious and safe as standard stereotactic frame-based biopsy. However, frameless biopsy can alleviate the suffering of the patient and reduce the total duration of the procedure. Remebot robot-assisted frameless brain biopsy is easy to use and better accepted by patients than frame-based biopsy.
Collapse
Affiliation(s)
- Shiqiang Wu
- Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Junwen Wang
- Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Pan Gao
- Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Weihua Liu
- Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Feng Hu
- Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Wei Jiang
- Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Ting Lei
- Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Kai Shu
- Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| |
Collapse
|
19
|
Optimal Design of Adaptive Robust Control for the Delta Robot with Uncertainty: Fuzzy Set-Based Approach. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10103472] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
An optimal control design for the uncertain Delta robot is proposed in the paper. The uncertain factors of the Delta robot include the unknown dynamic parameters, the residual vibration disturbances and the nonlinear joints friction, which are (possibly fast) time-varying and bounded. A fuzzy set theoretic approach is creatively used to describe the system uncertainty. With the fuzzily depicted uncertainty, an adaptive robust control, based on the fuzzy dynamic model, is established. It designs an adaptation mechanism, consisting of the leakage term and the dead-zone, to estimate the uncertainty information. An optimal design is constructed for the Delta robot and solved by minimizing a fuzzy set-based performance index. Unlike the traditional fuzzy control methods (if-then rules-based), the proposed control scheme is deterministic and fuzzily optimized. It is proven that the global solution in the closed form for this optimal design always exists and is unique. This research provides the Delta parallel robot a novel optimal control to guarantee the system performance regardless of the uncertainty. The effectiveness of the proposed control is illustrated by a series of simulation experiments. The results reveal that the further applications in other robots are feasible.
Collapse
|
20
|
Minchev G, Kronreif G, Ptacek W, Kettenbach J, Micko A, Wurzer A, Maschke S, Wolfsberger S. Frameless Stereotactic Brain Biopsies: Comparison of Minimally Invasive Robot-Guided and Manual Arm-Based Technique. Oper Neurosurg (Hagerstown) 2020; 19:292-301. [DOI: 10.1093/ons/opaa123] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2019] [Accepted: 03/17/2020] [Indexed: 11/14/2022] Open
Abstract
Abstract
BACKGROUND
Most brain biopsies are still performed with the aid of a navigation-guided mechanical arm. Due to the manual trajectory alignment without rigid skull contact, frameless aiming devices are prone to considerably lower accuracy.
OBJECTIVE
To compare a novel minimally invasive robot-guided biopsy technique with rigid skull fixation to a standard frameless manual arm biopsy procedure.
METHODS
Accuracy, procedural duration, diagnostic yield, complication rate, and cosmetic result were retrospectively assessed in 40 consecutive cases of frameless stereotactic biopsies and compared between a minimally invasive robotic technique using the iSYS1 guidance device (iSYS Medizintechnik GmbH) (robot-guided group [ROB], n = 20) and a manual arm-based technique (group MAN, n = 20).
RESULTS
Application of the robotic technique resulted in significantly higher accuracy at entry point (group ROB median 1.5 mm [0.4-3.2 mm] vs manual arm-based group (MAN) 2.2 mm [0.2-5.2 mm], P = .019) and at target point (group ROB 1.5 mm [0.4-2.8 mm] vs group MAN 2.8 mm [1.4-4.9 mm], P = .001), without increasing incision to suture time (group ROB 30.0 min [20-45 min vs group MAN 32.5 min [range 20-60 min], P = .09) and significantly shorter skin incision length (group ROB 16.3 mm [12.7-23.4 mm] vs group MAN 24.2 mm [18.0-37.0 mm], P = .008).
CONCLUSION
According to our data, the proposed technique of minimally invasive robot-guided brain biopsies can improve accuracy without increasing operating time while being equally safe and effective compared to a standard frameless arm-based manual biopsy technique.
Collapse
Affiliation(s)
- Georgi Minchev
- Department of Neurosurgery, Medical University of Vienna, Austria
| | - Gernot Kronreif
- Austrian Center for Medical Innovation and Technology (ACMIT), Wiener Neustadt, Austria
| | - Wolfgang Ptacek
- Austrian Center for Medical Innovation and Technology (ACMIT), Wiener Neustadt, Austria
| | - Joachim Kettenbach
- Institute of Diagnostic, Interventional Radiology and Nuclear Medicine, Landesklinikum Wiener Neustadt, Wiener Neustadt, Austria
| | - Alexander Micko
- Department of Neurosurgery, Medical University of Vienna, Austria
| | - Ayguel Wurzer
- Department of Neurosurgery, Medical University of Vienna, Austria
| | - Svenja Maschke
- Department of Neurosurgery, Medical University of Vienna, Austria
| | | |
Collapse
|
21
|
Ye M, Li W, Chan DTM, Chiu PWY, Li Z. A Semi-Autonomous Stereotactic Brain Biopsy Robot With Enhanced Safety. IEEE Robot Autom Lett 2020. [DOI: 10.1109/lra.2020.2967732] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
22
|
Giamouriadis A, Perera D, Safdar A, Vergani F, Bhangoo R, Gullan R, Ashkan K. Safety and accuracy of frameless electromagnetic-navigated (AXIEM TM)-guided brain lesion biopsies: a large single-unit study. Acta Neurochir (Wien) 2019; 161:2587-2593. [PMID: 31642996 DOI: 10.1007/s00701-019-04093-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Accepted: 10/01/2019] [Indexed: 11/29/2022]
Abstract
BACKGROUND Brain biopsies are required to establish a definitive histological diagnosis for brain lesions that have been identified on imaging in order to guide further treatment for patients. OBJECTIVE Various navigation systems are in use but little up to date evidence is available regarding the safety and accuracy of a frameless, electromagnetic technique to target brain lesions. METHODS Data was collected retrospectively on all patients that had brain biopsies at our institution from 01/01/2010 to 31/12/2017. Operation notes, neuropathology reports, and clinical notes on electronic patient record were used to determine whether biopsy of adequate identifiable abnormal tissue was achieved, whether a definitive diagnosis was established, any adverse events occurred, and if a repeat biopsy was carried out. RESULTS Three hundred seventy-one AxiEM (Medtronic, Minneapolis, USA)-guided brain tumor biopsies were performed in this 8-year period. Three hundred forty-nine (94.07%) procedures provided definitive tissue diagnosis, 22 (5.93%) were non diagnostic; in 6 cases (1.62%), repeat biopsy was performed and adverse events which caused clinical compromise were observed in 4 patients (1.08%). CONCLUSIONS The AxiEM is a fast, effective, and safe frameless and pinless neuronavigational system. It offers a high degree of accuracy required for the establishment of a definitive diagnosis, permitting optimal further treatment, and thus improving patient outcomes.
Collapse
Affiliation(s)
| | | | | | - Francesco Vergani
- Department of Neurosurgery, King's College Hospital NHS Foundation Trust, London, UK
| | - Ranjeev Bhangoo
- Department of Neurosurgery, King's College Hospital NHS Foundation Trust, London, UK
| | - Richard Gullan
- Department of Neurosurgery, King's College Hospital NHS Foundation Trust, London, UK
| | - Keyoumars Ashkan
- Department of Neurosurgery, King's College Hospital NHS Foundation Trust, London, UK
| |
Collapse
|
23
|
Fomenko A, Serletis D. Robotic Stereotaxy in Cranial Neurosurgery: A Qualitative Systematic Review. Neurosurgery 2019; 83:642-650. [PMID: 29253265 DOI: 10.1093/neuros/nyx576] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2017] [Accepted: 11/01/2017] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Modern-day stereotactic techniques have evolved to tackle the neurosurgical challenge of accurately and reproducibly accessing specific brain targets. Neurosurgical advances have been made in synergy with sophisticated technological developments and engineering innovations such as automated robotic platforms. Robotic systems offer a unique combination of dexterity, durability, indefatigability, and precision. OBJECTIVE To perform a systematic review of robotic integration for cranial stereotactic guidance in neurosurgery. Specifically, we comprehensively analyze the strengths and weaknesses of a spectrum of robotic technologies, past and present, including details pertaining to each system's kinematic specifications and targeting accuracy profiles. METHODS Eligible articles on human clinical applications of cranial robotic-guided stereotactic systems between 1985 and 2017 were extracted from several electronic databases, with a focus on stereotactic biopsy procedures, stereoelectroencephalography, and deep brain stimulation electrode insertion. RESULTS Cranial robotic stereotactic systems feature serial or parallel architectures with 4 to 7 degrees of freedom, and frame-based or frameless registration. Indications for robotic assistance are diversifying, and include stereotactic biopsy, deep brain stimulation and stereoelectroencephalography electrode placement, ventriculostomy, and ablation procedures. Complication rates are low, and mainly consist of hemorrhage. Newer systems benefit from increasing targeting accuracy, intraoperative imaging ability, improved safety profiles, and reduced operating times. CONCLUSION We highlight emerging future directions pertaining to the integration of robotic technologies into future neurosurgical procedures. Notably, a trend toward miniaturization, cost-effectiveness, frameless registration, and increasing safety and accuracy characterize successful stereotactic robotic technologies.
Collapse
Affiliation(s)
- Anton Fomenko
- Manitoba Neurosurgery Laboratory, Children's Hospital Research Institute of Manitoba, Winnipeg, Manitoba, Canada.,Section of Neurosurgery, Health Sciences Centre, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Demitre Serletis
- Manitoba Neurosurgery Laboratory, Children's Hospital Research Institute of Manitoba, Winnipeg, Manitoba, Canada.,Section of Neurosurgery, Health Sciences Centre, University of Manitoba, Winnipeg, Manitoba, Canada
| |
Collapse
|
24
|
Chen Y, Zhu G, Shi L, Liu D, Zhang X, Liu Y, Yuan T, Du T, Zhang J. Establishment of a novel mesial temporal lobe epilepsy rhesus monkey model via intra-hippocampal and intra-amygdala kainic acid injection assisted by neurosurgical robot system. Brain Res Bull 2019; 149:32-41. [DOI: 10.1016/j.brainresbull.2019.04.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2019] [Revised: 03/26/2019] [Accepted: 04/02/2019] [Indexed: 01/11/2023]
|
25
|
Sciortino T, Fernandes B, Conti Nibali M, Gay LG, Rossi M, Lopci E, Colombo AE, Elefante MG, Pessina F, Bello L, Riva M. Frameless stereotactic biopsy for precision neurosurgery: diagnostic value, safety, and accuracy. Acta Neurochir (Wien) 2019; 161:967-974. [PMID: 30895395 DOI: 10.1007/s00701-019-03873-w] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2018] [Accepted: 03/06/2019] [Indexed: 11/25/2022]
Abstract
BACKGROUND Stereotactic biopsy is consistently employed to characterize cerebral lesions in patients who are not suitable for microsurgical resection. In the past years, technical improvement and neuroimaging advancements contributed to increase the diagnostic yield, the safety, and the application of this procedure. Currently, in addition to histological diagnosis, the molecular analysis is considered essential in the diagnostic process to properly select therapeutic and prognostic algorithms in a personalized approach. The present study reports our experience with frameless stereotactic brain biopsy in this molecular era. METHODS One hundred forty consecutive patients treated from January 2013 to September 2018 were analyzed. Biopsies were performed using the Brainlab Varioguide® frameless stereotactic system. Patients' clinical and demographic data, the time of occupation of the operating room, the surgical time, the morbidity, and the diagnostic yield in providing a histological and molecular diagnosis were recorded and evaluated. RESULTS The overall diagnostic yield was 93.6% with nine procedures resulting non-diagnostic. Among 110 patients with glioma, the IDH-1 mutational status was characterized in 108 cases (98.2%), resulting wild-type in all subjects but 3; MGMT methylation was characterized in 96 cases (87.3%), resulting present in 60 patients, and 1p/19q codeletion was founded in 6 of the 20 cases of grade II-III gliomas analyzed. All the specimens were apt for molecular analysis when performed. Bleeding requiring surgical drainage occurred in 2.1% of the cases; 8 (5.7%) asymptomatic hemorrhages requiring no treatment were observed. No biopsy-related mortality was recorded. Median length of hospital stay was 5 days (IQR 4-8) with mean surgical time of 60.77 min (± 23.12) and 137.44 ± 24.1 min of total occupation time of the operative room. CONCLUSIONS Stereotactic frameless biopsy is a safe, feasible, and fast procedure to obtain a histological and molecular diagnosis.
Collapse
Affiliation(s)
- Tommaso Sciortino
- Università degli Studi di Milano, Milan, Italy
- Unit of Oncological Neurosurgery, Humanitas Clinical and Research Center - IRCCS, Rozzano (MI), Italy
| | - Bethania Fernandes
- Unit of Pathology, Humanitas Clinical and Research Center - IRCCS, Rozzano (MI), Italy
| | - Marco Conti Nibali
- Università degli Studi di Milano, Milan, Italy
- Unit of Oncological Neurosurgery, Humanitas Clinical and Research Center - IRCCS, Rozzano (MI), Italy
| | - Lorenzo G Gay
- Università degli Studi di Milano, Milan, Italy
- Unit of Oncological Neurosurgery, Humanitas Clinical and Research Center - IRCCS, Rozzano (MI), Italy
| | - Marco Rossi
- Università degli Studi di Milano, Milan, Italy
- Unit of Oncological Neurosurgery, Humanitas Clinical and Research Center - IRCCS, Rozzano (MI), Italy
| | - Egesta Lopci
- Unit of Nuclear Medicine, Humanitas Clinical and Research Center - IRCCS, Rozzano (MI), Italy
| | - Anna E Colombo
- Unit of Pathology, Humanitas Clinical and Research Center - IRCCS, Rozzano (MI), Italy
| | - Maria G Elefante
- Unit of Pathology, Humanitas Clinical and Research Center - IRCCS, Rozzano (MI), Italy
| | - Federico Pessina
- Unit of Oncological Neurosurgery, Humanitas Clinical and Research Center - IRCCS, Rozzano (MI), Italy
- Department of Biomedical Sciences, Humanitas University, Rozzano (MI), Italy
| | - Lorenzo Bello
- Unit of Oncological Neurosurgery, Humanitas Clinical and Research Center - IRCCS, Rozzano (MI), Italy
- Department of Oncology and Hemato-Oncology, Università degli Studi di Milano, Milan, Italy
| | - Marco Riva
- Unit of Oncological Neurosurgery, Humanitas Clinical and Research Center - IRCCS, Rozzano (MI), Italy.
- Department of Medical Biotechnology and Translational Medicine, Università degli Studi di Milano, Milan, Italy.
| |
Collapse
|
26
|
Zhu G, Chen Y, Du T, Liu D, Zhang X, Liu Y, Yuan T, Shi L, Zhang J. The Accuracy and Feasibility of Robotic Assisted Lead Implantation in Nonhuman Primates. Neuromodulation 2019; 22:441-450. [DOI: 10.1111/ner.12951] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 02/14/2019] [Accepted: 02/27/2019] [Indexed: 11/30/2022]
Affiliation(s)
- Guan‐Yu Zhu
- Department of Neurosurgery Beijing Tiantan Hospital, Capital Medical University Beijing China
| | - Ying‐Chuan Chen
- Department of Neurosurgery Beijing Tiantan Hospital, Capital Medical University Beijing China
| | - Ting‐Ting Du
- Department of Functional Neurosurgery Beijing Neurosurgical Institute, Capital Medical University Beijing China
| | - De‐Feng Liu
- Department of Neurosurgery Beijing Tiantan Hospital, Capital Medical University Beijing China
| | - Xin Zhang
- Department of Functional Neurosurgery Beijing Neurosurgical Institute, Capital Medical University Beijing China
| | - Yu‐Ye Liu
- Department of Neurosurgery Beijing Tiantan Hospital, Capital Medical University Beijing China
| | - Tian‐Shuo Yuan
- Department of Neurosurgery Beijing Tiantan Hospital, Capital Medical University Beijing China
| | - Lin Shi
- Department of Neurosurgery Beijing Tiantan Hospital, Capital Medical University Beijing China
| | - Jian‐Guo Zhang
- Department of Neurosurgery Beijing Tiantan Hospital, Capital Medical University Beijing China
- Department of Functional Neurosurgery Beijing Neurosurgical Institute, Capital Medical University Beijing China
- Beijing Key Laboratory of Neurostimulation Beijing China
| |
Collapse
|
27
|
Stereotactic brain biopsy: evaluation of robot-assisted procedure in 60 patients. Acta Neurochir (Wien) 2019; 161:545-552. [PMID: 30675655 DOI: 10.1007/s00701-019-03808-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2018] [Accepted: 01/12/2019] [Indexed: 10/27/2022]
Abstract
BACKGROUND Frameless stereotactic biopsies, particularly robot-assisted procedures are increasing in neurosurgery centers. Results of these procedures should be at least equal to or greater than frame-based reference procedure. Evaluate robot-assisted technology is necessary in particular, when a team has chosen to switch from one to another method. OBJECTIVE The objective of our prospective work was (i) to evaluate the success rate of contributive robotic-assisted biopsy in 60 patients, to report the morbidity and mortality associated with the procedure and (ii) to compare it with literature data. METHODS We performed a prospective and descriptive study including 60 consecutive patients having had robotic-assisted stereotactic biopsy at the Rouen University Hospital, France. All patients had presurgical imaging before the procedure included Magnetic Resonance Imaging merged with Computed Tomography scan acquisition. Registration was mostly performed with a touch-free laser (57/60). A control Computed Tomography scan was always realized at day 0 or day 1 after surgery. Data collected were success rate, bleeding, clinical worsening, infection, and mortality. RESULTS All the biopsies were considered as contributive and lead to the final diagnosis. In 41/60 patients (68%), the lesion was glial. Six in 60 patients (10%) had visible bleeding without clinical worsening related, 5/60 patients (8.5%) showed clinical impairment following surgery, which was permanent in 2 patients, and 1/60 patient presented generalized seizures. We did not report any infection and mortality. CONCLUSION Robot-assisted frameless surgery is efficient and provides a reasonable alternative to frame-based procedure. The operating time can be reduced, without increasing morbidity and mortality rates.
Collapse
|
28
|
Desroches J, Lemoine É, Pinto M, Marple E, Urmey K, Diaz R, Guiot MC, Wilson BC, Petrecca K, Leblond F. Development and first in-human use of a Raman spectroscopy guidance system integrated with a brain biopsy needle. JOURNAL OF BIOPHOTONICS 2019; 12:e201800396. [PMID: 30636032 DOI: 10.1002/jbio.201800396] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2018] [Revised: 12/10/2018] [Accepted: 01/09/2019] [Indexed: 05/22/2023]
Abstract
Navigation-guided brain biopsies are the standard of care for diagnosis of several brain pathologies. However, imprecise targeting and tissue heterogeneity often hinder obtaining high-quality tissue samples, resulting in poor diagnostic yield. We report the development and first clinical testing of a navigation-guided fiberoptic Raman probe that allows surgeons to interrogate brain tissue in situ at the tip of the biopsy needle prior to tissue removal. The 900 μm diameter probe can detect high spectral quality Raman signals in both the fingerprint and high wavenumber spectral regions with minimal disruption to the neurosurgical workflow. The probe was tested in three brain tumor patients, and the acquired spectra in both normal brain and tumor tissue demonstrated the expected spectral features, indicating the quality of the data. As a proof-of-concept, we also demonstrate the consistency of the acquired Raman signal with different systems and experimental settings. Additional clinical development is planned to further evaluate the performance of the system and develop a statistical model for real-time tissue classification during the biopsy procedure.
Collapse
Affiliation(s)
- Joannie Desroches
- Department of Engineering Physics, Polytechnique Montreal, Montreal, Québec, Canada
- Laboratory of Radiological Optics, Centre de Recherche du Centre Hospitalier de l'Université de Montréal, Montreal, Québec, Canada
| | - Émile Lemoine
- Department of Engineering Physics, Polytechnique Montreal, Montreal, Québec, Canada
- Laboratory of Radiological Optics, Centre de Recherche du Centre Hospitalier de l'Université de Montréal, Montreal, Québec, Canada
| | - Michael Pinto
- Department of Engineering Physics, Polytechnique Montreal, Montreal, Québec, Canada
| | - Eric Marple
- Research and development, EMVision LLC, Loxahatchee, Florida
| | - Kirk Urmey
- Research and development, EMVision LLC, Loxahatchee, Florida
| | - Roberto Diaz
- Brain Tumour Research Centre, Montreal Neurological Institute and Hospital, Department of Neurology and Neurosurgery, McGill University, Montreal, Québec, Canada
| | - Marie-Christine Guiot
- Division of Neuropathology, Department of Pathology, Montreal Neurological Institute and Hospital, McGill University, Montreal, Québec, Canada
| | - Brian C Wilson
- Laser Biophysics group, Princess Margaret Cancer Centre-University Health Network/University of Toronto, Toronto, Ontario, Canada
| | - Kevin Petrecca
- Brain Tumour Research Centre, Montreal Neurological Institute and Hospital, Department of Neurology and Neurosurgery, McGill University, Montreal, Québec, Canada
| | - Frédéric Leblond
- Department of Engineering Physics, Polytechnique Montreal, Montreal, Québec, Canada
- Laboratory of Radiological Optics, Centre de Recherche du Centre Hospitalier de l'Université de Montréal, Montreal, Québec, Canada
| |
Collapse
|
29
|
Legnani FG, Franzini A, Mattei L, Saladino A, Casali C, Prada F, Perin A, Cojazzi V, Saini M, Kronreif G, Wolfsberger S, DiMeco F. Image-Guided Biopsy of Intracranial Lesions with a Small Robotic Device (iSYS1): A Prospective, Exploratory Pilot Study. Oper Neurosurg (Hagerstown) 2019; 17:403-412. [DOI: 10.1093/ons/opy411] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Accepted: 01/04/2019] [Indexed: 11/13/2022] Open
Abstract
Abstract
BACKGROUND
Robotic technologies have been used in the neurosurgical operating rooms for the last 30 yr. They have been adopted for several stereotactic applications and, particularly, image-guided biopsy of intracranial lesions which are not amenable for open surgical resection.
OBJECTIVE
To assess feasibility, safety, accuracy, and diagnostic yield of robot-assisted frameless stereotactic brain biopsy with a recently introduced miniaturized device (iSYS1; Interventional Systems Medizintechnik GmbH, Kitzbühel, Austria), fixed to the Mayfield headholder by a jointed arm.
METHODS
Clinical and surgical data of all patients undergoing frameless stereotactic biopsies using the iSYS1 robotized system from October 2016 to December 2017 have been prospectively collected and analyzed. Facial surface registration has been adopted for optical neuronavigation.
RESULTS
Thirty-nine patients were included in the study. Neither mortality nor morbidity related to the surgical procedure performed with the robot was recorded. Diagnostic tissue samples were obtained in 38 out of 39 procedures (diagnostic yield per procedure was 97.4%). All patients received a definitive histological diagnosis. Mean target error was 1.06 mm (median 1 mm, range 0.1-4 mm).
CONCLUSION
The frameless robotic iSYS1-assisted biopsy technique was determined to be feasible, safe, and accurate procedure; moreover, the diagnostic yield was high. The surface matching registration method with computed tomography as the reference image set did not negatively affect the accuracy of the procedure.
Collapse
Affiliation(s)
- Federico G Legnani
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico C. Besta, Università degli Studi, Milan, Italy
| | - Andrea Franzini
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico C. Besta, Università degli Studi, Milan, Italy
| | - Luca Mattei
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico C. Besta, Università degli Studi, Milan, Italy
| | - Andrea Saladino
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico C. Besta, Università degli Studi, Milan, Italy
| | - Cecilia Casali
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico C. Besta, Università degli Studi, Milan, Italy
| | - Francesco Prada
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico C. Besta, Università degli Studi, Milan, Italy
- Department of Neurological Surgery, University of Virginia Health Science Center, Charlottesville, Virginia
| | - Alessandro Perin
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico C. Besta, Università degli Studi, Milan, Italy
| | - Vittoria Cojazzi
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico C. Besta, Università degli Studi, Milan, Italy
| | - Marco Saini
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico C. Besta, Università degli Studi, Milan, Italy
| | - Gernot Kronreif
- Austrian Center for Medical Innovation and Technology, ACMIT Gmbh, Wiener Neustadt, Austria
| | - Stefan Wolfsberger
- Department of Neurosurgery, Medical University of Vienna, Vienna, Austria
| | - Francesco DiMeco
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico C. Besta, Università degli Studi, Milan, Italy
- Department of Neurosurgery, Johns Hopkins University, Baltimore, Maryland
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| |
Collapse
|
30
|
Dawes W, Marcus HJ, Tisdall M, Aquilina K. Robot-assisted stereotactic brainstem biopsy in children: prospective cohort study. J Robot Surg 2018; 13:575-579. [PMID: 30523502 PMCID: PMC6647535 DOI: 10.1007/s11701-018-0899-x] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Accepted: 11/28/2018] [Indexed: 11/28/2022]
Abstract
Tumours located within the brainstem comprise approximately a tenth of all paediatric brain tumours. Surgical biopsy of these tumours is technically challenging and has historically been associated with considerable risk. To this end, robot-assisted surgery theoretically allows for increased accuracy and precision. In this study we report our experience using the Neuromate robot (Renishaw, Gloucestershire, UK) to perform robot-assisted stereotactic biopsy in children with tumours located within the brainstem. An uncontrolled prospective cohort study was performed (phase II) according to the IDEAL model for safe surgical innovation. All cases were recorded on a prospectively maintained database. The database was searched over a 2-year period between the 1st December 2015 and the 31st November 2017 to identify all children with brainstem tumours that underwent robot-assisted stereotactic brain biopsy. When accessible, the post-operative MRI scans and pre-operative plans were compared to assess the target point localisation error (TPLE). Adverse events were recorded prospectively according to whether they resulted in increased hospital stay, caused neurological injury, or lead to death. In all, 11 consecutive children were identified with brain tumours located within the brainstem. In 10/11 cases specimens were diagnostic; in the remaining case a further biopsy was successful. The most frequent pathology was DIPG (7/15). Seven patients underwent an early post-operative volumetric MRI; the calculated median TPLE was 2.7 mm (range 0.5-4.2 mm). There were no surgical complications noted. Robot-assisted stereotactic biopsy in children appears to be feasible and safe. Research databases and comparative studies are warranted to further assess the technique.
Collapse
Affiliation(s)
- William Dawes
- Department of Neurosurgery, Great Ormond Street Hospital, London, UK
| | - Hani J Marcus
- Department of Neurosurgery, Great Ormond Street Hospital, London, UK. .,Wellcome EPSRC Centre for Interventional and Surgical Sciences, University College London, 8.02 Malet Place Building, Gower Street, London, WC1E 6BT, UK.
| | - Martin Tisdall
- Department of Neurosurgery, Great Ormond Street Hospital, London, UK
| | - Kristian Aquilina
- Department of Neurosurgery, Great Ormond Street Hospital, London, UK
| |
Collapse
|
31
|
The role of frameless stereotactic biopsy in contemporary neuro-oncology: molecular specifications and diagnostic yield in biopsied glioma patients. J Neurooncol 2018; 141:183-194. [DOI: 10.1007/s11060-018-03024-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Accepted: 10/03/2018] [Indexed: 12/31/2022]
|
32
|
Ilgın C, Topuzoğlu A. Extracellular Vesicles in Psychiatry Research in the Context of RDoC Criteria. Psychiatry Investig 2018; 15:1011-1018. [PMID: 30380817 PMCID: PMC6259002 DOI: 10.30773/pi.2018.09.17] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Revised: 09/06/2018] [Accepted: 09/17/2018] [Indexed: 12/18/2022] Open
Abstract
The analysis of extracellular vesicles has been accelerated because of the technological advancements in omics methods in recent decades. Extracellular vesicles provide multifaceted information regarding the functional status of the cells. This information would be critical in case of central nervous system cells, which are confined in a relatively sealed biological compartment. This obstacle is more dramatic in psychiatric disorders since their diagnosis primarily depend on the symptoms and signs of the patients. In this paper, we reviewed this rapidly advancing field by discussing definition of extracellular vesicles, their biogenesis and potential use as clinical biomarkers. Then we focused on their potential use in psychiatric disorders in the context of diagnosis and treatment of these disorders. Finally, we tried to combine the RDoC (Research Domain Criteria) with the use of extracellular vesicles in psychiatry research and practice. This review may offer new insights in both basic and translational research focusing on psychiatric disorders.
Collapse
Affiliation(s)
- Can Ilgın
- Department of Public Health, Marmara University School of Medicine, Istanbul, Turkey
| | - Ahmet Topuzoğlu
- Department of Public Health, Marmara University School of Medicine, Istanbul, Turkey
| |
Collapse
|
33
|
Nuzzi R, Brusasco L. State of the art of robotic surgery related to vision: brain and eye applications of newly available devices. Eye Brain 2018; 10:13-24. [PMID: 29440943 PMCID: PMC5798758 DOI: 10.2147/eb.s148644] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Background Robot-assisted surgery has revolutionized many surgical subspecialties, mainly where procedures have to be performed in confined, difficult to visualize spaces. Despite advances in general surgery and neurosurgery, in vivo application of robotics to ocular surgery is still in its infancy, owing to the particular complexities of microsurgery. The use of robotic assistance and feedback guidance on surgical maneuvers could improve the technical performance of expert surgeons during the initial phase of the learning curve. Evidence acquisition We analyzed the advantages and disadvantages of surgical robots, as well as the present applications and future outlook of robotics in neurosurgery in brain areas related to vision and ophthalmology. Discussion Limitations to robotic assistance remain, that need to be overcome before it can be more widely applied in ocular surgery. Conclusion There is heightened interest in studies documenting computerized systems that filter out hand tremor and optimize speed of movement, control of force, and direction and range of movement. Further research is still needed to validate robot-assisted procedures.
Collapse
Affiliation(s)
- Raffaele Nuzzi
- Department of Surgical Sciences, Eye Clinic, University of Torino, Turin, Italy
| | - Luca Brusasco
- Department of Surgical Sciences, Eye Clinic, University of Torino, Turin, Italy
| |
Collapse
|
34
|
Marcus HJ, Vakharia VN, Ourselin S, Duncan J, Tisdall M, Aquilina K. Robot-assisted stereotactic brain biopsy: systematic review and bibliometric analysis. Childs Nerv Syst 2018; 34:1299-1309. [PMID: 29744625 PMCID: PMC5996011 DOI: 10.1007/s00381-018-3821-y] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2018] [Accepted: 05/02/2018] [Indexed: 12/21/2022]
Abstract
INTRODUCTION Stereotactic brain biopsy represents one of the earliest applications of surgical robotics. The aim of the present systematic review and bibliometric analysis was to evaluate the literature supporting robot-assisted brain biopsy and the extent to which the scientific community has accepted the technique. METHODS The Cochrane and PubMed databases were searched over a 30-year period between 1st of January 1988 and 31st of December 2017. Titles and abstracts were screened to identify publications that met the following criteria: (1) featured patients with brain pathology, (2) undergoing stereotactic brain biopsy, (3) reporting robot-assisted surgery, and (4) outcome data were provided. The reference lists of selected studies were also sought, and expert opinion sought to identify further eligible publications. Selected manuscripts were then reviewed, and data extracted on effectiveness and safety. The status of scientific community acceptance was determined using a progressive scholarly acceptance analysis. RESULTS All identified studies were non-randomised, including 1 retrospective cohort study and 14 case series or reports. The diagnostic biopsy rate varied from 75 to 100%, and the average target accuracy varied from 0.9 to 4.5 mm. Use of the robot was aborted in two operations owing to geometric inaccessibility and an error in image registration but no associated adverse events were reported. A compounding progressive scholarly acceptance analysis suggested a trend towards acceptance of the technique by the scientific community. CONCLUSIONS In conclusion, robot-assisted stereotactic brain biopsy is an increasingly mainstream tool in the neurosurgical armamentarium. Further evaluation should proceed along the IDEAL framework with research databases and comparative trials.
Collapse
Affiliation(s)
- Hani J Marcus
- Department of Neurosurgery, Great Ormond Street Hospital, London, UK.
- Wellcome EPSRC Centre for Interventional and Surgical Sciences, University College London, 8.02 Malet Place Building, Gower Street, London, WC1E 6BT, UK.
| | - Vejay N Vakharia
- Wellcome EPSRC Centre for Interventional and Surgical Sciences, University College London, 8.02 Malet Place Building, Gower Street, London, WC1E 6BT, UK
- UCL Institute of Neurology, National Hospital for Neurology and Neurosurgery, Queen Square, London, WC1N 3BG, UK
| | - Sebastien Ourselin
- Wellcome EPSRC Centre for Interventional and Surgical Sciences, University College London, 8.02 Malet Place Building, Gower Street, London, WC1E 6BT, UK
| | - John Duncan
- Wellcome EPSRC Centre for Interventional and Surgical Sciences, University College London, 8.02 Malet Place Building, Gower Street, London, WC1E 6BT, UK
- UCL Institute of Neurology, National Hospital for Neurology and Neurosurgery, Queen Square, London, WC1N 3BG, UK
| | - Martin Tisdall
- Department of Neurosurgery, Great Ormond Street Hospital, London, UK
| | - Kristian Aquilina
- Department of Neurosurgery, Great Ormond Street Hospital, London, UK
| |
Collapse
|
35
|
Dlaka D, Švaco M, Chudy D, Jerbić B, Šekoranja B, Šuligoj F, Vidaković J, Almahariq F, Romić D. Brain biopsy performed with the RONNA G3 system: a case study on using a novel robotic navigation device for stereotactic neurosurgery. Int J Med Robot 2017; 14. [PMID: 29232764 DOI: 10.1002/rcs.1884] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2017] [Revised: 11/09/2017] [Accepted: 11/16/2017] [Indexed: 11/10/2022]
Abstract
BACKGROUND Robotic neuronavigation is becoming an important tool for neurosurgeons. We present a case study of a frameless stereotactic biopsy guided by the RONNA G3 robotic neuronavigation system. METHODS A 45 year-old patient with a history of vertigo, nausea and vomiting was diagnosed with multiple periventricular lesions. Neurological status was unremarkable. A frameless robotic biopsy of a brain lesion was performed. RESULTS Three tissue samples were obtained. There were no intraoperative or postoperative complications. Histological analysis showed a B-cell lymphoma. After merging the preoperative CT scan with the postoperative MRI and CT scans, the measured error between the planned and the postoperatively measured entry point was 2.24 mm and the measured error between the planned and postoperatively measured target point was 2.33 mm. CONCLUSIONS The RONNA G3 robotic system was used to navigate a Sedan brain biopsy needle to take tissue samples and could be a safe and precise tool for brain biopsy.
Collapse
Affiliation(s)
- Domagoj Dlaka
- Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia
| | - Marko Švaco
- Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia
| | - Darko Chudy
- Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia
| | - Bojan Jerbić
- Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia
| | - Bojan Šekoranja
- Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia
| | - Filip Šuligoj
- Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia
| | - Josip Vidaković
- Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia
| | - Fadi Almahariq
- Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia
| | - Dominik Romić
- Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia
| |
Collapse
|
36
|
Meng F, Zhai F, Zeng B, Ding H, Wang G. An automatic markerless registration method for neurosurgical robotics based on an optical camera. Int J Comput Assist Radiol Surg 2017; 13:253-265. [DOI: 10.1007/s11548-017-1675-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2017] [Accepted: 10/11/2017] [Indexed: 10/18/2022]
|
37
|
Lehocky CA, Fellows-Mayle W, Engh JA, Riviere CN. Tip Design for Safety of Steerable Needles for Robot-Controlled Brain Insertion. ROBOTIC SURGERY : RESEARCH AND REVIEWS 2017; 4:107-114. [PMID: 29170740 PMCID: PMC5695876 DOI: 10.2147/rsrr.s141085] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Background Current practice in neurosurgical needle insertion is limited by the straight trajectories inherent with rigid probes. One technique allowing curvilinear trajectories involves flexible bevel-tipped needles, which bend during insertion due to their asymmetry. In the brain, safety will require avoidance of the sharp tips often used in laboratory studies, in favor of a more rounded profile. Steering performance, on the other hand, requires maximal asymmetry. Design of safe bevel-tipped brain needles thus involves management of this tradeoff by adjusting needle gauge, bevel angle, and fillet (or tip) radius to arrive at a design that is suitably asymmetrical while producing strain, strain rate, and stress below the levels that would damage brain tissue. Methods Designs with a variety of values of needle radius, bevel angle, and fillet radius were evaluated in finite-element simulations of simultaneous insertion and rotation. Brain tissue was modeled as a hyperelastic, linear viscoelastic material. Based on the literature available, safety thresholds of 0.19 strain, 10 s-1 strain rate, and 120 kPa stress were used. Safe values of needle radius, bevel angle, and fillet radius were selected, along with an appropriate velocity envelope for safe operation. The resulting needle was fabricated and compared with a Sedan side-cutting brain biopsy needle in a study in the porcine model in vivo (N=3). Results The prototype needle selected was 1.66 mm in diameter, with bevel angle of 10° and fillet radius of 0.25 mm. Upon examination of postoperative CT and histological images, no differences in tissue trauma or hemorrhage were noted between the prototype needle and the Sedan needle. Conclusions The study indicates a general design technique for safe bevel-tipped brain needles based on comparison with relevant damage thresholds for strain, strain rate, and stress. The full potential of the technique awaits the determination of more exact safety thresholds.
Collapse
Affiliation(s)
- Craig A Lehocky
- Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA
| | - Wendy Fellows-Mayle
- Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Johnathan A Engh
- Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Cameron N Riviere
- The Robotics Institute, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
38
|
De Benedictis A, Trezza A, Carai A, Genovese E, Procaccini E, Messina R, Randi F, Cossu S, Esposito G, Palma P, Amante P, Rizzi M, Marras CE. Robot-assisted procedures in pediatric neurosurgery. Neurosurg Focus 2017; 42:E7. [DOI: 10.3171/2017.2.focus16579] [Citation(s) in RCA: 104] [Impact Index Per Article: 14.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVEDuring the last 3 decades, robotic technology has rapidly spread across several surgical fields due to the continuous evolution of its versatility, stability, dexterity, and haptic properties. Neurosurgery pioneered the development of robotics, with the aim of improving the quality of several procedures requiring a high degree of accuracy and safety. Moreover, robot-guided approaches are of special interest in pediatric patients, who often have altered anatomy and challenging relationships between the diseased and eloquent structures. Nevertheless, the use of robots has been rarely reported in children. In this work, the authors describe their experience using the ROSA device (Robotized Stereotactic Assistant) in the neurosurgical management of a pediatric population.METHODSBetween 2011 and 2016, 116 children underwent ROSA-assisted procedures for a variety of diseases (epilepsy, brain tumors, intra- or extraventricular and tumor cysts, obstructive hydrocephalus, and movement and behavioral disorders). Each patient received accurate preoperative planning of optimal trajectories, intraoperative frameless registration, surgical treatment using specific instruments held by the robotic arm, and postoperative CT or MR imaging.RESULTSThe authors performed 128 consecutive surgeries, including implantation of 386 electrodes for stereo-electroencephalography (36 procedures), neuroendoscopy (42 procedures), stereotactic biopsy (26 procedures), pallidotomy (12 procedures), shunt placement (6 procedures), deep brain stimulation procedures (3 procedures), and stereotactic cyst aspiration (3 procedures). For each procedure, the authors analyzed and discussed accuracy, timing, and complications.CONCLUSIONSTo the best their knowledge, the authors present the largest reported series of pediatric neurosurgical cases assisted by robotic support. The ROSA system provided improved safety and feasibility of minimally invasive approaches, thus optimizing the surgical result, while minimizing postoperative morbidity.
Collapse
Affiliation(s)
| | - Andrea Trezza
- 1Department of Neuroscience and Neurosurgical Unit and
- 2Neurosurgery, Department of Surgery and Translational Medicine, Milan Center for Neuroscience, University of Milano-Bicocca, San Gerardo Hospital, Monza
| | - Andrea Carai
- 1Department of Neuroscience and Neurosurgical Unit and
| | - Elisabetta Genovese
- 3Enterprise Risk Management, Medical Physics Department, Bambino Gesù Children’s Hospital, IRCCS, Rome
| | | | | | - Franco Randi
- 1Department of Neuroscience and Neurosurgical Unit and
| | - Silvia Cossu
- 1Department of Neuroscience and Neurosurgical Unit and
| | | | - Paolo Palma
- 1Department of Neuroscience and Neurosurgical Unit and
| | | | - Michele Rizzi
- 4“Claudio Munari” Center for Epilepsy Surgery, Niguarda Hospital, Milan; and
- 5Department of Neuroscience, University of Parma, Italy
| | | |
Collapse
|
39
|
Bradac O, Steklacova A, Nebrenska K, Vrana J, de Lacy P, Benes V. Accuracy of VarioGuide Frameless Stereotactic System Against Frame-Based Stereotaxy: Prospective, Randomized, Single-Center Study. World Neurosurg 2017; 104:831-840. [PMID: 28454992 DOI: 10.1016/j.wneu.2017.04.104] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2016] [Revised: 04/14/2017] [Accepted: 04/17/2017] [Indexed: 10/19/2022]
Abstract
INTRODUCTION Frameless stereotactic brain biopsy systems are widely used today. VarioGuide (VG) is a relatively novel frameless system. Its accuracy was studied in a laboratory setting but has not yet been studied in the clinical setting. The purpose of this study was to determine its accuracy and diagnostic yield and to compare this with frame-based (FB) stereotaxy. MATERIAL AND METHODS Overall, 53 patients (33 males and 20 females, 60 ± 15 years old) were enrolled into this prospective, randomized, single-center study. Twenty-six patients were randomized into the FB group and 27 patients into the VG group. Real trajectory was pointed on intraoperative magnetic resonance. The distance of the targets and angle deviation between the planned and real trajectories were computed. The overall discomfort of the patient was subjectively assessed by the visual analog scale score. RESULTS The median lesion volume was 5 mL (interquartile range [IQR]: 2-16 mL) (FB) and 16 mL (IQR: 2-27 mL) (VG), P = 0.133. The mean distance of the targets was 2.7 ± 1.1 mm (FB) and 2.9 ± 1.3 mm (VG), P = 0.456. Mean angle deviation was 2.6 ± 1.3 deg (FB) and 3.5 ± 2.1 deg (VG), P = 0.074. Diagnostic yield was 93% (25/27) in VG and 96% (25/26) in FB, P = 1.000. Mean operating time was 47 ± 26 minutes (FB) and 59 ± 31 minutes (VG), P = 0.140. One minor bleeding was encountered in the VG group. Overall patient discomfort was significantly higher in the FB group (visual analog scale score 2.5 ± 2.1 vs. 1.2 ± 0.6, P = 0,004). CONCLUSIONS The VG system proved to be comparable in terms of the trajectory accuracy, rate of complications and diagnostic yield compared with the "gold standard" represented by the traditional FB stereotaxy for patients undergoing brain biopsy. VG is also better accepted by patients.
Collapse
Affiliation(s)
- Ondrej Bradac
- Department of Neurosurgery and Neurooncology, Military University Hospital and First Medical Faculty, Charles University, Prague, The Czech Republic.
| | - Anna Steklacova
- Department of Neurosurgery and Neurooncology, Military University Hospital and First Medical Faculty, Charles University, Prague, The Czech Republic
| | - Katerina Nebrenska
- Department of Neurosurgery and Neurooncology, Military University Hospital and First Medical Faculty, Charles University, Prague, The Czech Republic
| | - Jiri Vrana
- Department of Neuroradiology, Military University Hospital, Prague, The Czech Republic
| | - Patricia de Lacy
- Department of Neurosurgery, Royal Hallamshire Hospital, Sheffield, United Kingdom
| | - Vladimir Benes
- Department of Neurosurgery and Neurooncology, Military University Hospital and First Medical Faculty, Charles University, Prague, The Czech Republic
| |
Collapse
|
40
|
Minchev G, Kronreif G, Martínez-Moreno M, Dorfer C, Micko A, Mert A, Kiesel B, Widhalm G, Knosp E, Wolfsberger S. A novel miniature robotic guidance device for stereotactic neurosurgical interventions: preliminary experience with the iSYS1 robot. J Neurosurg 2017; 126:985-996. [DOI: 10.3171/2016.1.jns152005] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE
Robotic devices have recently been introduced in stereotactic neurosurgery in order to overcome the limitations of frame-based and frameless techniques in terms of accuracy and safety. The aim of this study is to evaluate the feasibility and accuracy of the novel, miniature, iSYS1 robotic guidance device in stereotactic neurosurgery.
METHODS
A preclinical phantom trial was conducted to compare the accuracy and duration of needle positioning between the robotic and manual technique in 162 cadaver biopsies. Second, 25 consecutive cases of tumor biopsies and intracranial catheter placements were performed with robotic guidance to evaluate the feasibility, accuracy, and duration of system setup and application in a clinical setting.
RESULTS
The preclinical phantom trial revealed a mean target error of 0.6 mm (range 0.1–0.9 mm) for robotic guidance versus 1.2 mm (range 0.1–2.6 mm) for manual positioning of the biopsy needle (p < 0.001). The mean duration was 2.6 minutes (range 1.3–5.5 minutes) with robotic guidance versus 3.7 minutes (range 2.0–10.5 minutes) with manual positioning (p < 0.001). Clinical application of the iSYS1 robotic guidance device was feasible in all but 1 case. The median real target error was 1.3 mm (range 0.2–2.6 mm) at entry and 0.9 mm (range 0.0–3.1 mm) at the target point. The median setup and instrument positioning times were 11.8 minutes (range 4.2–26.7 minutes) and 4.9 minutes (range 3.1–14.0 minutes), respectively.
CONCLUSIONS
According to the preclinical data, application of the iSYS1 robot can significantly improve accuracy and reduce instrument positioning time. During clinical application, the robot proved its high accuracy, short setup time, and short instrument positioning time, as well as demonstrating a short learning curve.
Collapse
Affiliation(s)
- Georgi Minchev
- 1Department of Neurosurgery, Medical University of Vienna, Vienna; and
| | - Gernot Kronreif
- 2Austrian Center of Medical Innovation and Technology, Wiener Neustadt, Austria
| | | | - Christian Dorfer
- 1Department of Neurosurgery, Medical University of Vienna, Vienna; and
| | - Alexander Micko
- 1Department of Neurosurgery, Medical University of Vienna, Vienna; and
| | - Aygül Mert
- 1Department of Neurosurgery, Medical University of Vienna, Vienna; and
| | - Barbara Kiesel
- 1Department of Neurosurgery, Medical University of Vienna, Vienna; and
| | - Georg Widhalm
- 1Department of Neurosurgery, Medical University of Vienna, Vienna; and
| | - Engelbert Knosp
- 1Department of Neurosurgery, Medical University of Vienna, Vienna; and
| | | |
Collapse
|
41
|
Diffuse intrinsic pontine gliomas in children: Interest of robotic frameless assisted biopsy. A technical note. Neurochirurgie 2016; 62:327-331. [DOI: 10.1016/j.neuchi.2016.07.005] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2015] [Revised: 07/03/2016] [Accepted: 07/17/2016] [Indexed: 11/20/2022]
|
42
|
Chan AY, Tran DKT, Gill AS, Hsu FPK, Vadera S. Stereotactic robot-assisted MRI-guided laser thermal ablation of radiation necrosis in the posterior cranial fossa: technical note. Neurosurg Focus 2016; 41:E5. [DOI: 10.3171/2016.4.focus1622] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Laser interstitial thermal therapy (LITT) is a minimally invasive procedure used to treat a variety of intracranial lesions. Utilization of robotic assistance with stereotactic procedures has gained attention due to potential for advantages over conventional techniques. The authors report the first case in which robot-assisted MRI-guided LITT was used to treat radiation necrosis in the posterior fossa, specifically within the cerebellar peduncle. The use of a stereotactic robot allowed the surgeon to perform LITT using a trajectory that would be extremely difficult with conventional arc-based techniques.
A 60-year-old man presented with facial weakness and brainstem symptoms consistent with radiation necrosis. He had a history of anaplastic astrocytoma that was treated with CyberKnife radiosurgery 1 year prior to presentation, and he did well for 11 months until his symptoms recurred. The location and form of the lesion precluded excision but made the patient a suitable candidate for LITT. The location and configuration of the lesion required a trajectory for LITT that was too low for arc-based stereotactic navigation, and thus the ROSA robot (Medtech) was used. Using preoperative MRI acquisitions, the lesion in the posterior fossa was targeted. Bone fiducials were used to improve accuracy in registration, and the authors obtained an intraoperative CT image that was then fused with the MR image by the ROSA robot. They placed the laser applicator and then ablated the lesion under real-time MR thermometry. There were no complications, and the patient tolerated the procedure well. Postoperative 2-month MRI showed complete resolution of the lesion, and the patient had some improvement in symptoms.
Collapse
Affiliation(s)
- Alvin Y. Chan
- 2Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Diem Kieu T. Tran
- 1Department of Neurological Surgery, University of California, Irvine, California; and
| | - Amandip S. Gill
- 1Department of Neurological Surgery, University of California, Irvine, California; and
| | - Frank P. K. Hsu
- 1Department of Neurological Surgery, University of California, Irvine, California; and
| | - Sumeet Vadera
- 1Department of Neurological Surgery, University of California, Irvine, California; and
| |
Collapse
|
43
|
Experimental new automatic tools for robotic stereotactic neurosurgery: towards “no hands” procedure of leads implantation into a brain target. J Neural Transm (Vienna) 2016; 123:737-750. [DOI: 10.1007/s00702-016-1575-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2016] [Accepted: 05/10/2016] [Indexed: 11/30/2022]
|
44
|
Ragel BT, Ryken TC, Kalkanis SN, Ziu M, Cahill D, Olson JJ. The role of biopsy in the management of patients with presumed diffuse low grade glioma: A systematic review and evidence-based clinical practice guideline. J Neurooncol 2015; 125:481-501. [PMID: 26530259 DOI: 10.1007/s11060-015-1866-2] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2015] [Accepted: 07/27/2015] [Indexed: 10/22/2022]
Abstract
QUESTION What is the optimal role of biopsy in the initial management of presumptive low-grade glioma in adults? TARGET POPULATION Adult patients with imaging suggestive of a low-grade glioma. RECOMMENDATIONS LEVEL III Stereotactic biopsy is recommended when definitive surgical resection is limited by lesions that are deep-seated, not resectable, and/or located within eloquent cortex, or in patients unable to undergo craniotomy due to medical co-morbidities to obtain the critical tissue diagnosis needed for targeted treatment planning for patients with low-grade gliomas. QUESTION What is the best technique for brain biopsy? TARGET POPULATION Adult patients with imaging suggestive of a low-grade glioma. RECOMMENDATIONS LEVEL III Frameless and frame-based stereotactic brain biopsy for low-grade gliomas are recommended based on clinical circumstances as they provide similar diagnostic yield, diagnostic accuracy, morbidity, and mortality. It is recommended the surgeon consider advanced imaging techniques (e.g., perfusion, spectroscopy, metabolic studies) to target specific regions of interest to potentially improve diagnostic accuracy.
Collapse
Affiliation(s)
- Brian T Ragel
- Rebound Orthopedics and Neurosurgery, 200 NE Mother Joseph Place, Suite 210, Vancouver, WA, 98664, USA.
| | - Timothy C Ryken
- Department of Neurosurgery, University of Kansas Medical Center, Kansas City, KS, USA
| | - Steven N Kalkanis
- Department of Neurosurgery, Henry Ford Health System, Detroit, MI, USA
| | - Mateo Ziu
- Department of Neurosurgery, Seton Brain and Spine Institute, Austin, TX, USA
| | | | - Jeffrey J Olson
- Department of Neurosurgery, Emory University School of Medicine, Atlanta, GA, USA
| |
Collapse
|
45
|
Contemporary frameless intracranial biopsy techniques: Might variation in safety and efficacy be expected? Acta Neurochir (Wien) 2015; 157:2011-6; discussion 2016. [PMID: 26315461 PMCID: PMC4604498 DOI: 10.1007/s00701-015-2543-0] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2015] [Accepted: 08/07/2015] [Indexed: 11/10/2022]
Abstract
Background Frameless stereotactic neuronavigation has proven to be a feasible technology to acquire brain biopsies with good accuracy and little morbidity and mortality. New systems are constantly introduced into the neurosurgical armamentarium, although few studies have actually evaluated and compared the diagnostic yield, morbidity, and mortality of various manufacturer’s frameless neuronavigation systems. The present study reports our experience with brain biopsy procedures performed using both the Medtronic Stealth TreonTM Vertek® and BrainLAB® Varioguide frameless stereotactic brain biopsy systems. Patients and methods All 247 consecutive biopsies from January 2008 until May 2013 were evaluated retrospectively. One hundred two biopsies each were performed using the Medtronic (2008–2009) and BrainLAB® system (2011–2013), respectively. The year 2010 was considered a transition year, in which 43 biopsies were performed with either system. Patient demographics, perioperative characteristics, and histological diagnosis were reviewed, and a comparison was made between the two brain biopsy systems. Results The overall diagnostic yield was 94.6 %, i.e., 11 biopsies were nondiagnostic, 5 (4.9 %) with the Medtronic and 6 (5.9 %) with the BrainLAB® system. No differences besides the operating time (108 vs 120 min) were found between the two biopsy methods. On average, 6.6 tissue samples were taken with either technique. Peri- and postoperative complications were seen in 5.3 % and 12.9 %, consisting of three symptomatic hemorrhages (1.2 %). Biopsy-related mortality occurred in 0.8 % of all biopsies. Conclusions Regarding diagnostic yield, complication rate, and biopsy-related mortality, there seems to be no difference between the frameless biopsy technique from Medtronic and BrainLAB®. In contemporary time, the neurosurgeon has many tools to choose from, all with a relatively fast learning curve and ever improving feasibility. Thus, the issue of choice involves not the results, but the familiarity, end-user friendliness, and overall comfort when operating the system.
Collapse
|
46
|
30 Years of Neurosurgical Robots: Review and Trends for Manipulators and Associated Navigational Systems. Ann Biomed Eng 2015; 44:836-46. [DOI: 10.1007/s10439-015-1475-4] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2015] [Accepted: 09/24/2015] [Indexed: 10/22/2022]
|
47
|
Grimm F, Naros G, Gutenberg A, Keric N, Giese A, Gharabaghi A. Blurring the boundaries between frame-based and frameless stereotaxy: feasibility study for brain biopsies performed with the use of a head-mounted robot. J Neurosurg 2015; 123:737-42. [PMID: 26067616 DOI: 10.3171/2014.12.jns141781] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT Frame-based stereotactic interventions are considered the gold standard for brain biopsies, but they have limitations with regard to flexibility and patient comfort because of the bulky head ring attached to the patient. Frameless image guidance systems that use scalp fiducial markers offer more flexibility and patient comfort but provide less stability and accuracy during drilling and biopsy needle positioning. Head-mounted robot-guided biopsies could provide the advantages of these 2 techniques without the downsides. The goal of this study was to evaluate the feasibility and safety of a robotic guidance device, affixed to the patient's skull through a small mounting platform, for use in brain biopsy procedures. METHODS This was a retrospective study of 37 consecutive patients who presented with supratentorial lesions and underwent brain biopsy procedures in which a surgical guidance robot was used to determine clinical outcomes and technical procedural operability. RESULTS The portable head-mounted device was well tolerated by the patients and enabled stable drilling and needle positioning during surgery. Flexible adjustments of predefined paths and selection of new trajectories were successfully performed intraoperatively without the need for manual settings and fixations. The patients experienced no permanent deficits or infections after surgery. CONCLUSIONS The head-mounted robot-guided approach presented here combines the stability of a bone-mounted set-up with the flexibility and tolerability of frameless systems. By reducing human interference (i.e., manual parameter settings, calibrations, and adjustments), this technology might be particularly useful in neurosurgical interventions that necessitate multiple trajectories.
Collapse
Affiliation(s)
- Florian Grimm
- Division of Functional and Restorative Neurosurgery, Department of Neurosurgery, Eberhard Karls University, Tuebingen; and
| | - Georgios Naros
- Division of Functional and Restorative Neurosurgery, Department of Neurosurgery, Eberhard Karls University, Tuebingen; and
| | - Angelika Gutenberg
- Department of Neurosurgery, Johannes Gutenberg University, Mainz, Germany
| | - Naureen Keric
- Department of Neurosurgery, Johannes Gutenberg University, Mainz, Germany
| | - Alf Giese
- Department of Neurosurgery, Johannes Gutenberg University, Mainz, Germany
| | - Alireza Gharabaghi
- Division of Functional and Restorative Neurosurgery, Department of Neurosurgery, Eberhard Karls University, Tuebingen; and
| |
Collapse
|
48
|
Iijima K, Hirato M, Miyagishima T, Horiguchi K, Sugawara K, Hirato J, Yokoo H, Yoshimoto Y. Microrecording and image-guided stereotactic biopsy of deep-seated brain tumors. J Neurosurg 2015; 123:978-88. [PMID: 25816085 DOI: 10.3171/2014.10.jns14963] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT Image-guided stereotactic brain tumor biopsy cannot easily obtain samples of small deep-seated tumor or selectively sample the most viable region of malignant tumor. Image-guided stereotactic biopsy in combination with depth microrecording was evaluated to solve such problems. METHODS Operative records, MRI findings, and pathological specimens were evaluated in 12 patients with small deep-seated brain tumor, in which image-guided stereotactic biopsy was performed with the aid of depth microrecording. The tumors were located in the caudate nucleus (1 patient), thalamus (7 patients), midbrain (2 patients), and cortex (2 patients). Surgery was performed with a frameless stereotactic system in 3 patients and with a frame-based stereotactic system in 9 patients. Microrecording was performed to study the electrical activities along the trajectory in the deep brain structures and the tumor. The correlations were studied between the electrophysiological, MRI, and pathological findings. Thirty-two patients with surface or large brain tumor were also studied, in whom image-guided stereotactic biopsy without microrecording was performed. RESULTS The diagnostic yield in the group with microrecording was 100% (low-grade glioma 4, high-grade glioma 4, diffuse large B-cell lymphoma 3, and germinoma 1), which was comparable to 93.8% in the group without microrecording. The postoperative complication rate was as low as that of the conventional image-guided method without using microelectrode recording, and the mortality rate was 0%, although the target lesions were small and deep-seated in all cases. Depth microrecording revealed disappearance of neural activity in the tumor regardless of the tumor type. Neural activity began to decrease from 6.3 ± 4.5 mm (mean ± SD) above the point of complete disappearance along the trajectory. Burst discharges were observed in 6 of the 12 cases, from 3 ± 1.4 mm above the point of decrease of neural activity. Injury discharges were often found at 0.5-1 mm along the trajectory between the area of decreased and disappeared neural activity. Close correlations between electrophysiological, MRI, and histological findings could be found in some cases. CONCLUSIONS Image-guided stereotactic biopsy performed using depth microrecording was safe, it provided accurate positional information in real time, and it could distinguish the tumor from brain structures during surgery. Moreover, this technique has potential for studying the epileptogenicity of the brain tumor.
Collapse
Affiliation(s)
| | | | | | | | | | - Junko Hirato
- Clinical Department of Pathology, Gunma University Hospital, Maebashi, Gunma, Japan
| | - Hideaki Yokoo
- Human Pathology, Gunma University Graduate School of Medicine; and
| | | |
Collapse
|
49
|
Lefranc M, Capel C, Pruvot-Occean AS, Fichten A, Desenclos C, Toussaint P, Le Gars D, Peltier J. Frameless robotic stereotactic biopsies: a consecutive series of 100 cases. J Neurosurg 2015; 122:342-52. [DOI: 10.3171/2014.9.jns14107] [Citation(s) in RCA: 88] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
OBJECT
Stereotactic biopsy procedures are an everyday part of neurosurgery. The procedure provides an accurate histological diagnosis with the least possible morbidity. Robotic stereotactic biopsy needs to be an accurate, safe, frameless, and rapid technique. This article reports the clinical results of a series of 100 frameless robotic biopsies using a Medtech ROSA device.
METHODS
The authors retrospectively analyzed their first 100 frameless stereotactic biopsies performed with the robotic ROSA device: 84 biopsies were performed by frameless robotic surface registration, 7 were performed by robotic bone fiducial marker registration, and 9 were performed by scalp fiducial marker registration. Intraoperative flat-panel CT scanning was performed concomitantly in 25 cases. The operative details of the robotic biopsies, the diagnostic yield, and mortality and morbidity data observed in this series are reported.
RESULTS
A histological diagnosis was established in 97 patients. No deaths or permanent morbidity related to surgery were observed. Six patients experienced transient neurological worsening. Six cases of bleeding within the lesion or along the biopsy trajectory were observed on postoperative CT scans but were associated with transient clinical symptoms in only 2 cases. Stereotactic surgery was performed with patients in the supine position in 93 cases and in the prone position in 7 cases. The use of fiducial markers was reserved for posterior fossa biopsy via a transcerebellar approach, via an occipital approach, or for pediatric biopsy.
CONCLUSIONS
ROSA frameless stereotactic biopsies appear to be accurate and safe robotized frameless procedures.
Collapse
|
50
|
Faria C, Erlhagen W, Rito M, De Momi E, Ferrigno G, Bicho E. Review of Robotic Technology for Stereotactic Neurosurgery. IEEE Rev Biomed Eng 2015; 8:125-37. [DOI: 10.1109/rbme.2015.2428305] [Citation(s) in RCA: 57] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|