51
|
Wang H, Wan Y, Tam KF, Ling S, Bai Y, Deng Y, Liu Y, Zhang H, Cheung WH, Qin L, Cheng JCY, Leung KS, Li Y. Resistive vibration exercise retards bone loss in weight-bearing skeletons during 60 days bed rest. Osteoporos Int 2012; 23:2169-78. [PMID: 22159820 DOI: 10.1007/s00198-011-1839-z] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2011] [Accepted: 10/31/2011] [Indexed: 11/30/2022]
Abstract
UNLABELLED Countermeasures are desirable to retard bone loss during long-term space flight. We evaluated the effect of an intervention protocol on bed rest-induced bone loss. INTRODUCTION We developed a resistive vibration exercise (RVE) platform to test if an intervention RVE protocol would be effective to protect bed rest-induced bone loss. METHODS Fourteen male subjects were assigned randomly to either the RVE group (n = 7) that performed daily supervised resistive vibration exercise or to the no any exercise control (CON) group (n = 7). Both dual-energy X-ray absorptiometry and peripheral quantitative computed tomography were used to monitor changes in bone mineral density. RESULTS RVE significantly prevented bone loss at multiple skeletal sites, including calcaneus, distal tibia, hip, and lumbar spine (L2-L4). The ratio of urinary calcium and creatinine was found higher after starting bed rest in CON group while no significant changes were observed in RVE group. No significant temporal change was found for osteocalcin-N during and after bed rest in CON group. However, a significant increase was shown after bed rest in RVE group. In both groups, the urinary concentration of bone resorption markers, such as C-telopeptide of type I collagen (CTX-I) and deoxypyridinoline (DPD), were significantly elevated after bed rest. In the CON group, no significant temporal effect was found for hydroxyproline (HOP), CTX-I, and DPD during bed rest and the serum concentration of HOP and TGF-β significantly increased about 52.04% and 24.03%, respectively only after bed rest. However, all these markers tended to decrease in the RVE group. CONCLUSIONS Our results might imply that the intervention of RVE retarded bone loss induced by simulated microgravity in humans that was mainly attributed to its anabolic effects.
Collapse
Affiliation(s)
- H Wang
- State Key Lab of Space Medicine Fundamentals and Application, China Astronaut Research and Training Center, Beijing, People's Republic of China
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
52
|
Abdulameer SA, Syed Sulaiman SA, Hassali MAA, Subramaniam K, Sahib MN. Is there a link between osteoporosis and type 1 diabetes? Findings from a systematic review of the literature. Diabetol Int 2012. [DOI: 10.1007/s13340-012-0083-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
53
|
Shaw CN, Hofmann CL, Petraglia MD, Stock JT, Gottschall JS. Neandertal humeri may reflect adaptation to scraping tasks, but not spear thrusting. PLoS One 2012; 7:e40349. [PMID: 22815742 PMCID: PMC3399840 DOI: 10.1371/journal.pone.0040349] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2012] [Accepted: 06/04/2012] [Indexed: 11/23/2022] Open
Abstract
Unique compared with recent and prehistoric Homo sapiens, Neandertal humeri are characterised by a pronounced right-dominant bilateral strength asymmetry and an anteroposteriorly strengthened diaphyseal shape. Remodeling in response to asymmetric forces imposed during regular underhanded spear thrusting is the most influential explanatory hypothesis. The core tenet of the “Spear Thrusting Hypothesis”, that underhand thrusting requires greater muscle activity on the right side of the body compared to the left, remains untested. It is unclear whether alternative subsistence behaviours, such as hide processing, might better explain this morphology. To test this, electromyography was used to measure muscle activity at the primary movers of the humerus (pectoralis major (PM), anterior (AD) and posterior deltoid (PD)) during three distinct spear-thrusting tasks and four separate scraping tasks. Contrary to predictions, maximum muscle activity (MAX) and total muscle activity (TOT) were significantly higher (all values, p<.05) at the left (non-dominant) AD, PD and PM compared to the right side of the body during spear thrusting tasks. Thus, the muscle activity required during underhanded spearing tasks does not lend itself to explaining the pronounced right dominant strength asymmetry found in Neandertal humeri. In contrast, during the performance of all three unimanual scraping tasks, right side MAX and TOT were significantly greater at the AD (all values, p<.01) and PM (all values, p<.02) compared to the left. The consistency of the results provides evidence that scraping activities, such as hide preparation, may be a key behaviour in determining the unusual pattern of Neandertal arm morphology. Overall, these results yield important insight into the Neandertal behavioural repertoire that aided survival throughout Pleistocene Eurasia.
Collapse
Affiliation(s)
- Colin N Shaw
- PAVE Research Group, Department of Archaeology & Anthropology, University of Cambridge, Cambridge, United Kingdom.
| | | | | | | | | |
Collapse
|
54
|
Trabecular bone response to mechanical loading in ovariectomized Sprague-Dawley rats depends on baseline bone quantity. J Biomech 2012; 45:2046-9. [DOI: 10.1016/j.jbiomech.2012.05.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2011] [Revised: 05/09/2012] [Accepted: 05/13/2012] [Indexed: 11/21/2022]
|
55
|
Manske SL, Good CA, Zernicke RF, Boyd SK. High-frequency, low-magnitude vibration does not prevent bone loss resulting from muscle disuse in mice following botulinum toxin injection. PLoS One 2012; 7:e36486. [PMID: 22590551 PMCID: PMC3349718 DOI: 10.1371/journal.pone.0036486] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2011] [Accepted: 04/09/2012] [Indexed: 11/18/2022] Open
Abstract
High-frequency, low-magnitude vibration enhances bone formation ostensibly by mimicking normal postural muscle activity. We tested this hypothesis by examining whether daily exposure to low-magnitude vibration (VIB) would maintain bone in a muscle disuse model with botulinum toxin type A (BTX). Female 16–18 wk old BALB/c mice (N = 36) were assigned to BTX-VIB, BTX-SHAM, VIB, or SHAM. BTX mice were injected with BTX (20 µL; 1 U/100 g body mass) into the left hindlimb posterior musculature. All mice were anaesthetized for 20 min/d, 5 d/wk, for 3 wk, and the left leg mounted to a holder. Through the holder, VIB mice received 45 Hz, ±0.6 g sinusoidal acceleration without weight bearing. SHAM mice received no vibration. At baseline and 3 wk, muscle cross-sectional area (MCSA) and tibial bone properties (epiphysis, metaphysis and diaphysis) were assessed by in vivo micro-CT. Bone volume fraction in the metaphysis decreased 12±9% and 7±6% in BTX-VIB and BTX-SHAM, but increased in the VIB and SHAM. There were no differences in dynamic histomorphometry outcomes between BTX-VIB and BTX nor between VIB and SHAM. Thus, vibration did not prevent bone loss induced by a rapid decline in muscle activity nor produce an anabolic effect in normal mice. The daily loading duration was shorter than would be expected from postural muscle activity, and may have been insufficient to prevent bone loss. Based on the approach used in this study, vibration does not prevent bone loss in the absence of muscle activity induced by BTX.
Collapse
MESH Headings
- Animals
- Bone Diseases, Metabolic/chemically induced
- Bone Diseases, Metabolic/pathology
- Bone Diseases, Metabolic/physiopathology
- Bone Diseases, Metabolic/therapy
- Botulinum Toxins, Type A/adverse effects
- Botulinum Toxins, Type A/pharmacology
- Female
- Mice
- Mice, Inbred BALB C
- Muscle, Skeletal/metabolism
- Muscle, Skeletal/pathology
- Muscle, Skeletal/physiopathology
- Muscular Disorders, Atrophic/chemically induced
- Muscular Disorders, Atrophic/pathology
- Muscular Disorders, Atrophic/physiopathology
- Muscular Disorders, Atrophic/therapy
- Neurotoxins/adverse effects
- Neurotoxins/pharmacology
- Physical Therapy Modalities
- Tibia/pathology
- Tibia/physiopathology
- Vibration
Collapse
Affiliation(s)
- Sarah L. Manske
- Faculty of Kinesiology, University of Calgary, Calgary, Canada
- Schulich School of Engineering, University of Calgary, Calgary, Canada
| | - Craig A. Good
- Schulich School of Engineering, University of Calgary, Calgary, Canada
| | - Ronald F. Zernicke
- Faculty of Kinesiology, University of Calgary, Calgary, Canada
- Faculty of Medicine, University of Calgary, Calgary, Canada
- Departments of Orthopaedic Surgery and Biomedical Engineering and School of Kinesiology, University of Michigan, Ann Arbor, Michigan, United States of America
- * E-mail:
| | - Steven K. Boyd
- Schulich School of Engineering, University of Calgary, Calgary, Canada
| |
Collapse
|
56
|
Thompson WR, Rubin CT, Rubin J. Mechanical regulation of signaling pathways in bone. Gene 2012; 503:179-93. [PMID: 22575727 DOI: 10.1016/j.gene.2012.04.076] [Citation(s) in RCA: 287] [Impact Index Per Article: 22.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2012] [Revised: 03/20/2012] [Accepted: 04/22/2012] [Indexed: 12/21/2022]
Abstract
A wide range of cell types depend on mechanically induced signals to enable appropriate physiological responses. The skeleton is particularly dependent on mechanical information to guide the resident cell population towards adaptation, maintenance and repair. Research at the organ, tissue, cell and molecular levels has improved our understanding of how the skeleton can recognize the functional environment, and how these challenges are translated into cellular information that can site-specifically alter phenotype. This review first considers those cells within the skeleton that are responsive to mechanical signals, including osteoblasts, osteoclasts, osteocytes and osteoprogenitors. This is discussed in light of a range of experimental approaches that can vary parameters such as strain, fluid shear stress, and pressure. The identity of mechanoreceptor candidates is approached, with consideration of integrins, pericellular tethers, focal adhesions, ion channels, cadherins, connexins, and the plasma membrane including caveolar and non-caveolar lipid rafts and their influence on integral signaling protein interactions. Several mechanically regulated intracellular signaling cascades are detailed including activation of kinases (Akt, MAPK, FAK), β-catenin, GTPases, and calcium signaling events. While the interaction of bone cells with their mechanical environment is complex, an understanding of mechanical regulation of bone signaling is crucial to understanding bone physiology, the etiology of diseases such as osteoporosis, and to the development of interventions to improve bone strength.
Collapse
Affiliation(s)
- William R Thompson
- Department of Medicine, University of North Carolina, Chapel Hill, NC 27599, USA.
| | | | | |
Collapse
|
57
|
Wallace IJ, Tommasini SM, Judex S, Garland T, Demes B. Genetic variations and physical activity as determinants of limb bone morphology: An experimental approach using a mouse model. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY 2012; 148:24-35. [DOI: 10.1002/ajpa.22028] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2011] [Accepted: 01/03/2012] [Indexed: 01/16/2023]
|
58
|
Mandibular corpus bone strains during mastication in goats (Capra hircus): A comparison of ingestive and rumination chewing. Arch Oral Biol 2011; 56:960-71. [DOI: 10.1016/j.archoralbio.2011.02.014] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2010] [Revised: 02/10/2011] [Accepted: 02/11/2011] [Indexed: 11/20/2022]
|
59
|
Shaw CN. Is ‘hand preference’ coded in the hominin skeleton? An in-vivo study of bilateral morphological variation. J Hum Evol 2011; 61:480-7. [DOI: 10.1016/j.jhevol.2011.06.004] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2010] [Revised: 01/23/2011] [Accepted: 06/24/2011] [Indexed: 11/25/2022]
|
60
|
Halldin A, Jimbo R, Johansson CB, Wennerberg A, Jacobsson M, Albrektsson T, Hansson S. The effect of static bone strain on implant stability and bone remodeling. Bone 2011; 49:783-9. [PMID: 21782050 DOI: 10.1016/j.bone.2011.07.003] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2011] [Revised: 06/15/2011] [Accepted: 07/04/2011] [Indexed: 10/18/2022]
Abstract
Bone remodeling is a process involving both dynamic and static bone strain. Although there exist numerous studies on the effect of dynamic strain on implant stability and bone remodeling, the effect of static strain has yet to be clarified. Hence, for this purpose, the effect of static bone strain on implant stability and bone remodeling was investigated in rabbits. Based on Finite Element (FE) simulation two different test implants, with a diametrical increase of 0.15 mm (group A) and 0.05 mm (group B) creating static strains in the bone of 0.045 and 0.015 respectively, were inserted in the femur (group A) and the proximal tibia metaphysis (groups A and B respectively) of 14 rabbits to observe the biological response. Both groups were compared to control implants, with no diametrical increase (group C), which were placed in the opposite leg. At the time of surgery, the insertion torque (ITQ) was measured to represent the initial stability. The rabbits were euthanized after 24 days and the removal torque (RTQ) was measured to analyze the effect on implant stability and bone remodeling. The mean ITQ value was significantly higher for both groups A and B compared to group C regardless of the bone type. The RTQ value was significantly higher in tibia for groups A and B compared to group C while group A placed in femur presented no significant difference compared to group C. The results suggest that increased static strain in the bone not only creates higher implant stability at the time of insertion, but also generates increased implant stability throughout the observation period.
Collapse
Affiliation(s)
- Anders Halldin
- Department of Prosthodontics, Faculty of Odontology, Malmö University, Malmö, Sweden.
| | | | | | | | | | | | | |
Collapse
|
61
|
Al Nazer R, Lanovaz J, Kawalilak C, Johnston JD, Kontulainen S. Direct in vivo strain measurements in human bone-a systematic literature review. J Biomech 2011; 45:27-40. [PMID: 21889149 DOI: 10.1016/j.jbiomech.2011.08.004] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2011] [Revised: 08/08/2011] [Accepted: 08/09/2011] [Indexed: 11/26/2022]
Abstract
Bone strain is the governing stimuli for the remodeling process necessary in the maintenance of bone's structure and mechanical strength. Strain gages are the gold standard and workhorses of human bone experimental strain analysis in vivo. The objective of this systematic literature review is to provide an overview for direct in vivo human bone strain measurement studies and place the strain results within context of current theories of bone remodeling (i.e. mechanostat theory). We employed a standardized search strategy without imposing any time restriction to find English language studies indexed in PubMed and Web of Science databases that measured human bone strain in vivo. Twenty-four studies met our final inclusion criteria. Seven human bones were subjected to strain measurements in vivo including medial tibia, second metatarsal, calcaneus, proximal femur, distal radius, lamina of vertebra and dental alveolar. Peak strain magnitude recorded was 9096 με on the medial tibia during basketball rebounding and the peak strain rate magnitude was -85,500 με/s recorded at the distal radius during forward fall from standing, landing on extended hands. The tibia was the most exposed site for in vivo strain measurements due to accessibility and being a common pathologic site of stress fracture in the lower extremity. This systematic review revealed that most of the strains measured in vivo in different bones were generally within the physiological loading zone defined by the mechanostat theory, which implies stimulation of functional adaptation necessary to maintain bone mechanical integrity.
Collapse
Affiliation(s)
- R Al Nazer
- College of Kinesiology, [corrected] University of Saskatchewan, Canada.
| | | | | | | | | |
Collapse
|
62
|
Buehring B, Belavý DL, Michaelis I, Gast U, Felsenberg D, Rittweger J. Changes in lower extremity muscle function after 56 days of bed rest. J Appl Physiol (1985) 2011; 111:87-94. [DOI: 10.1152/japplphysiol.01294.2010] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Preservation of muscle function, known to decline in microgravity and simulation (bed rest), is important for successful spaceflight missions. Hence, there is great interest in developing interventions to prevent muscle-function loss. In this study, 20 males underwent 56 days of bed rest. Ten volunteers were randomized to do resistive vibration exercise (RVE). The other 10 served as controls. RVE consisted of muscle contractions against resistance and concurrent whole-body vibration. Main outcome parameters were maximal isometric plantar-flexion force (IPFF), electromyography (EMG)/force ratio, as well as jumping power and height. Measurements were obtained before and after bed rest, including a morning and evening assessment on the first day of recovery from bed rest. IPFF (−17.1%), jumping peak power (−24.1%), and height (−28.5%) declined ( P < 0.05) in the control group. There was a trend to EMG/force ratio decrease (−20%; P = 0.051). RVE preserved IPFF and mitigated the decline of countermovement jump performance (peak power −12.2%; height −14.2%). In both groups, IPFF was reduced between the two measurements of the first day of reambulation. This study indicates that bed rest and countermeasure exercises differentially affect the various functions of skeletal muscle. Moreover, the time course during recovery needs to be considered more thoroughly in future studies, as IPFF declined not only with bed rest but also within the first day of reambulation. RVE was effective in maintaining IPFF but only mitigated the decline in jumping performance. More research is needed to develop countermeasures that maintain muscle strength as well as other muscle functions including power.
Collapse
Affiliation(s)
- B. Buehring
- Center for Muscle and Bone Research, Charité Universitätsmedizin Berlin, Free and Humboldt Universities, Berlin, Germany
- Cleveland Clinic, Cleveland, Ohio
| | - D. L. Belavý
- Center for Muscle and Bone Research, Charité Universitätsmedizin Berlin, Free and Humboldt Universities, Berlin, Germany
| | - I. Michaelis
- Center for Muscle and Bone Research, Charité Universitätsmedizin Berlin, Free and Humboldt Universities, Berlin, Germany
| | - U. Gast
- Center for Muscle and Bone Research, Charité Universitätsmedizin Berlin, Free and Humboldt Universities, Berlin, Germany
| | - D. Felsenberg
- Center for Muscle and Bone Research, Charité Universitätsmedizin Berlin, Free and Humboldt Universities, Berlin, Germany
| | - J. Rittweger
- Institute for Biomedical Research into Human Movement and Health, Manchester Metropolitan University, United Kingdom; and
- Institute of Aerospace Medicine, German Aerospace Center (DLR), Cologne, Germany
| |
Collapse
|
63
|
Abstract
In the masticatory system, activities of muscles are the main source of force. The daily activity of the jaw muscle is a measure of the total daily loading of the tissues involved. This article gives an overview on the recent assessments of the physiology and ontogeny of the daily use of the jaw muscles. Variations in the characteristics of daily activity could be linked to differences in the types of fibers composing the muscles as well as to the properties of the underlying bone, although these relationships are not absolute. Experimental decrease of the hardness of foods eaten by rats and rabbits showed a significant decrease in the number of daily bursts of feeding. These reductions in daily muscular activity were accompanied by higher mineralization of bone and by a transition toward "faster" fiber types in the muscles. It was revealed in rabbits that the characteristics of the daily activities of muscles (total duration of activity, number and lengths of bursts) were not altered during the transition from suckling to chewing and remained largely unaffected during further postnatal development. These results suggest that, despite large anatomical and functional changes, the average daily load on the jaw muscles by the masticatory system appears to be established before chewing develops and remains largely unchanged all the way through development. Whenever the daily muscular activity changes, this seems to have a significant effect on the properties of the tissues involved.
Collapse
Affiliation(s)
- Geerling E J Langenbach
- Department of Functional Anatomy, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and VU University Amsterdam, Research Institute MOVE, Gustav Mahlerlaan, LA, Netherlands.
| |
Collapse
|
64
|
Ferreri SL, Talish R, Trandafir T, Qin YX. Mitigation of bone loss with ultrasound induced dynamic mechanical signals in an OVX induced rat model of osteopenia. Bone 2011; 48:1095-102. [PMID: 21241838 PMCID: PMC3078942 DOI: 10.1016/j.bone.2011.01.002] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2010] [Revised: 12/18/2010] [Accepted: 01/04/2011] [Indexed: 10/18/2022]
Abstract
This study tests the hypothesis that an ultrasound generated dynamic mechanical signal can attenuate bone loss in an estrogen deficient model of osteopenia. Eighty-four 16-week-old Sprague-Dawley rats were divided into six groups: baseline control, age-matched control, ovariectomy (OVX) control, OVX+5mW/cm(2) ultrasound (US), OVX+30mW/cm(2) US and OVX+100mW/cm(2) US. Low intensity pulsed ultrasound (LIPUS) was delivered transdermally at the L4/L5 vertebrae, using gel-coupled plane wave US transducers. The signal, characterized by 200μs pulses of 1.5MHz sine waves repeating at 1kHz with spatial-averaged temporal-averaged (SATA) intensities of 5, 30 or 100mW/cm(2), was applied 20 min/day, 5 days/week for 4 weeks. OVX treatment reduced bone volume fraction 40% and compromised microstructure at 4 weeks. LIPUS treatment, however, significantly increased BV/TV (+33%) compared to OVX controls for the 100mW/cm(2) treated group. SMI and Tb.N showed significant improvements compared with OVX for the 100mW/cm(2) treated group and Tb.Th was significantly improved in the 30 and 100mW/cm(2) treated groups. Improvements in bone's microstructural characteristics with 100mW/cm(2) US treatment translated into improved load bearing characteristics, including a significant 42% increase in apparent level elastic modulus compared to OVX controls. Significant improvement of trabecular mechanical strength was also observed in the treated animals, e.g., principal compressive stress (represent bone's ability to resist loads) was significantly higher compared to OVX controls. Histomorphometric analysis also showed that treatment with 100mW/cm(2) US resulted in a 76% improvement in MS/BS. In addition, measures of bone quantity and quality at the femoral metaphysis suggest that LIPUS is site specific. This study indicates that localized ultrasound treatment, delivered at specific intensities, has beneficial effects on intact bone and may represent a novel intervention for bone loss.
Collapse
Affiliation(s)
- Suzanne L. Ferreri
- Orthopaedic Bioengineering Research Lab, Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York 11794
| | | | | | - Yi-Xian Qin
- Orthopaedic Bioengineering Research Lab, Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York 11794
| |
Collapse
|
65
|
Kasturi GC, Adler RA. Osteoporosis: nonpharmacologic management. PM R 2011; 3:562-72. [PMID: 21478069 DOI: 10.1016/j.pmrj.2010.12.014] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2010] [Revised: 12/10/2010] [Accepted: 12/17/2010] [Indexed: 01/01/2023]
Abstract
Osteoporosis is a chronic disorder of the skeleton causing increased bone fragility and fractures. In the second of our 3-part series, we discuss the beneficial effects of nonpharmacologic agents in the management of osteoporosis. We review the evidence supporting the use of exercise, whole-body vibration, hip protectors, low-intensity pulsed ultrasound, bracing, and vertebral augmentation procedures. The mechanism of action, precautions, and expected outcomes are discussed. Nonpharmacologic management of osteoporosis blends in very well with an overall exercise prescription. The nonpharmacologic interventions discussed are readily available and easy to implement. The use of such techniques demonstrates the important role of the physiatrist in the management of osteoporosis.
Collapse
Affiliation(s)
- Gopi C Kasturi
- Department of Neurology/Rehabilitation, VA Central California Health Care System, 2615 E Clinton Ave, Fresno, CA 93703, USA.
| | | |
Collapse
|
66
|
Case N, Sen B, Thomas JA, Styner M, Xie Z, Jacobs CR, Rubin J. Steady and oscillatory fluid flows produce a similar osteogenic phenotype. Calcif Tissue Int 2011; 88:189-97. [PMID: 21165611 PMCID: PMC3588160 DOI: 10.1007/s00223-010-9448-y] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2010] [Accepted: 11/16/2010] [Indexed: 02/04/2023]
Abstract
Mechanical loading induces positive changes in the skeleton due to direct effects on bone cells, which may include regulation of transcription factors that support osteoblast differentiation and function. Flow effects on osteoblast transcription factors have generally been evaluated after short exposures. In this work, we assayed flow effects on osteogenic genes at early and late time points in a preosteoblast (CIMC-4) cell line and evaluated both steady and oscillatory flows. Four hours of steady unidirectional flow decreased the level of RANKL mRNA 53 ± 7% below that of nonflowed cells, but increases in Runx2 and osterix mRNA (44 ± 22% and 129 ± 12%, respectively) were significant only after 12-19 h of continuous flow. Late flow effects on RANKL and osterix were also induced by an intermittent flow-rest protocol (four cycles of 1 h on/1 h off + overnight rest). Four hours of oscillatory flow decreased RANKL mRNA at this early time point (63 ± 2%) but did not alter either osterix or Runx2. When oscillatory flow was delivered using the intermittent flow-rest protocol, Runx2 and osterix mRNA increased significantly (85 ± 19% and 161 ± 22%, respectively). Both β-catenin and ERK1/2, known to be involved in RANKL regulation, were rapidly activated by steady flow. Inhibition of flow-activated ERK1/2 prevented the increase in osterix mRNA but not Runx2; Runx2 phosphorylation was increased by flow, an effect which likely contributes to osterix induction. This work shows that both steady and oscillatory fluid flows can support enhancement of an osteogenic phenotype.
Collapse
Affiliation(s)
- N Case
- Department of Medicine, University of North Carolina, Chapel Hill, 27599, USA.
| | | | | | | | | | | | | |
Collapse
|
67
|
Kotiya AA, Bayly PV, Silva MJ. Short-term low-strain vibration enhances chemo-transport yet does not stimulate osteogenic gene expression or cortical bone formation in adult mice. Bone 2011; 48:468-75. [PMID: 20937421 PMCID: PMC3039102 DOI: 10.1016/j.bone.2010.10.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/08/2010] [Revised: 09/20/2010] [Accepted: 10/04/2010] [Indexed: 11/19/2022]
Abstract
Development of low-magnitude mechanical stimulation (LMMS) based treatment strategies for a variety of orthopaedic issues requires better understanding of mechano-transduction and bone adaptation. Our overall goal was to study the tissue and molecular level changes in cortical bone in response to low-strain vibration (LSV: 70 Hz, 0.5 g, 300 με) and compare these to changes in response to a known anabolic stimulus: high-strain compression (HSC: rest inserted loading, 1000 με). Adult (6-7 months) C57BL/6 mice were used for the study and non-invasive axial compression of the tibia was used as a loading model. We first studied bone adaptation at the tibial mid-diaphysis, using dynamic histomorphometry, in response to daily loading of 15 min LSV or 60 cycles HSC for 5 consecutive days. We found that bone formation rate and mineral apposition rate were significantly increased in response to HSC but not LSV. The second aim was to compare chemo-transport in response to 5 min of LSV versus 5 min (30 cycles) of HSC. Chemo-transport increased significantly in response to both loading stimuli, particularly in the medial and the lateral quadrants of the cross section. Finally, we evaluated the expression of genes related to mechano-responsiveness, osteoblast differentiation, and matrix mineralization in tibias subjected to 15 min LSV or 60 cycles HSC for 1 day (4-h time point) or 4 consecutive days (4-day time point). The expression level of most of the genes remained unchanged in response to LSV at both time points. In contrast, the expression level of all the genes changed significantly in response to HSC at the 4-h time point. We conclude that short-term, low-strain vibration results in increased chemo-transport, yet does not stimulate an increase in mechano-responsive or osteogenic gene expression, and cortical bone formation in tibias of adult mice.
Collapse
Affiliation(s)
- Akhilesh A Kotiya
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA.
| | | | | |
Collapse
|
68
|
Sen B, Xie Z, Case N, Styner M, Rubin CT, Rubin J. Mechanical signal influence on mesenchymal stem cell fate is enhanced by incorporation of refractory periods into the loading regimen. J Biomech 2011; 44:593-9. [PMID: 21130997 PMCID: PMC3042527 DOI: 10.1016/j.jbiomech.2010.11.022] [Citation(s) in RCA: 120] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2010] [Revised: 11/09/2010] [Accepted: 11/13/2010] [Indexed: 12/19/2022]
Abstract
Mechanical signals of both low and high intensity are inhibitory to fat and anabolic to bone in vivo, and have been shown to directly affect mesenchymal stem cell pools from which fat and bone precursors emerge. To identify an idealized mechanical regimen which can regulate MSC fate, low intensity vibration (LIV; <10 microstrain, 90 Hz) and high magnitude strain (HMS; 20,000 microstrain, 0.17 Hz) were examined in MSC undergoing adipogenesis. Two x twenty minute bouts of either LIV or HMS suppressed adipogenesis when there was at least a 1h refractory period between bouts; this effect was enhanced when the rest period was extended to 3h. Mechanical efficacy to inhibit adipogenesis increased with additional loading bouts if a refractory period was incorporated. Mechanical suppression of adipogenesis with LIV involved inhibition of GSK3β with subsequent activation of β-catenin as has been shown for HMS. These data indicate that mechanical biasing of MSC lineage selection is more dependent on event scheduling than on load magnitude or duration. As such, a full day of rest should not be required to "reset" the mechanical responsiveness of MSCs, and suggests that incorporating several brief mechanical challenges within a 24h period may improve salutary endpoints in vivo. That two diverse mechanical inputs are enhanced by repetition after a refractory period suggests that rapid cellular adaptation can be targeted.
Collapse
Affiliation(s)
- Buer Sen
- Department of Medicine, University of North Carolina, Chapel Hill, NC, 27599
| | - Zhihui Xie
- Department of Medicine, University of North Carolina, Chapel Hill, NC, 27599
| | - Natasha Case
- Department of Medicine, University of North Carolina, Chapel Hill, NC, 27599
| | - Maya Styner
- Department of Medicine, University of North Carolina, Chapel Hill, NC, 27599
| | - Clinton T Rubin
- Department of Biomedical Engineering, State University of New York, Stony Brook, NY, 11794
| | - Janet Rubin
- Department of Medicine, University of North Carolina, Chapel Hill, NC, 27599
| |
Collapse
|
69
|
Lam H, Hu M, Qin YX. Alteration of contraction-to-rest ratio to optimize trabecular bone adaptation induced by dynamic muscle stimulation. Bone 2011; 48:399-405. [PMID: 20850577 PMCID: PMC3021645 DOI: 10.1016/j.bone.2010.09.018] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2010] [Revised: 09/01/2010] [Accepted: 09/13/2010] [Indexed: 10/19/2022]
Abstract
Disuse osteopenia has shown to decrease bone mineral density and compromise bone's integrity, i.e., in aging population and long-term functional disuse. The degree of attenuation of trabecular bone loss and deterioration of its microarchitecture is closely dependent on the mechanical loading parameters within the regimen. Dynamic muscle stimulation as a preventive countermeasure for disuse osteopenia has been shown to be effective. The objective of this study is to determine whether the contraction-to-rest ratio is a crucial parameter to affect the skeletal adaptive responses under a functional disuse environment. Fifty-six skeletally matured Sprague-Dawley rats were divided into seven groups for the 4-week experiment: baseline control, age-matched control, hindlimb suspended (HLS), and HLS plus muscle stimulation with a contraction-to-rest ratio of 1/4, 2/8, 4/6, and 2/28 s. Muscle stimulation was carried out for total of 10 min/day, 5 days/week, for 4 weeks. Trabecular bone in the distal femurs was analyzed with microcomputed tomography and histomorphometry. HLS alone for 4-week resulted in a 25-45% trabecular bone loss in the distal femur. Dynamic muscle stimulation, applied at 50 Hz frequency, with a 2/8 s contraction-to-rest ratio demonstrated significant attenuation of trabecular bone loss against the 4-week disuse, with up to +74% in bone volume fraction, +164% in connectivity, +20% in trabecular number, and -18% in spacing (p<0.05). Stimulation with 1/4 and 4/6 also showed similar effects but with lesser percentage differences when comparing to the HLS animals. Similarly, histomorphometric analysis showed partial enhancement in mineralizing surface and mineral apposition rate. The results suggested the potentials of dynamic muscle stimulation in regulating skeletal adaptive responses and illustrated the effects of optimized contraction-to-rest in mitigation of bone loss, in which 2/8 s has shown maximal adaptive response among all tested ratios.
Collapse
Affiliation(s)
- Hoyan Lam
- Orthopeadic Bioengineering Research Laboratory, Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794-5281
| | - Minyi Hu
- Orthopeadic Bioengineering Research Laboratory, Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794-5281
| | - Yi-Xian Qin
- Orthopeadic Bioengineering Research Laboratory, Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794-5281
| |
Collapse
|
70
|
Bergmann P, Body JJ, Boonen S, Boutsen Y, Devogelaer JP, Goemaere S, Kaufman J, Reginster JY, Rozenberg S. Loading and skeletal development and maintenance. J Osteoporos 2010; 2011:786752. [PMID: 21209784 PMCID: PMC3010667 DOI: 10.4061/2011/786752] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2010] [Accepted: 11/06/2010] [Indexed: 12/12/2022] Open
Abstract
Mechanical loading is a major regulator of bone mass and geometry. The osteocytes network is considered the main sensor of loads, through the shear stress generated by strain induced fluid flow in the lacuno-canalicular system. Intracellular transduction implies several kinases and phosphorylation of the estrogen receptor. Several extra-cellular mediators, among which NO and prostaglandins are transducing the signal to the effector cells. Disuse results in osteocytes apoptosis and rapid imbalanced bone resorption, leading to severe osteoporosis. Exercising during growth increases peak bone mass, and could be beneficial with regards to osteoporosis later in life, but the gain could be lost if training is abandoned. Exercise programs in adults and seniors have barely significant effects on bone mass and geometry at least at short term. There are few data on a possible additive effect of exercise and drugs in osteoporosis treatment, but disuse could decrease drugs action. Exercise programs proposed for bone health are tedious and compliance is usually low. The most practical advice for patients is to walk a minimum of 30 to 60 minutes per day. Other exercises like swimming or cycling have less effect on bone, but could reduce fracture risk indirectly by maintaining muscle mass and force.
Collapse
Affiliation(s)
- P. Bergmann
- Department of Nuclear Medicine, Laboratory of Clinical Chemistry and Experimental Medicine, CHU Brugmann, Université Libre de Bruxelles, 4 Pl. Van Gehuchten, 1020 Brussels, Belgium,*P. Bergmann:
| | - J. J. Body
- Department of Medicine, CHU Brugmann, Université Libre de Bruxelles, 1020 Brussels, Belgium
| | - S. Boonen
- Division of Gerontology and Geriatrics, Center for Musculoskeletal Research, Department of Experimental Medicine, Catholic Leuven University, 3000 Leuven, Belgium
| | - Y. Boutsen
- Department of Rheumatology, Mont-Godinne University Hospital, Université Catholique de Louvain, 1200 Brussels, Belgium
| | - J. P. Devogelaer
- Rheumatology Unit, Saint-Luc University Hospital, Université Catholique de Louvain, 1200 Brussels, Belgium
| | - S. Goemaere
- Unit for Osteoporosis and Metabolic Bone Diseases, Ghent University Hospital, 9000 Ghent, Belgium
| | - J. Kaufman
- Unit for Osteoporosis and Metabolic Bone Diseases, Ghent University Hospital, 9000 Ghent, Belgium
| | - J. Y. Reginster
- Department of Public Health Sciences, University of Liège, 4000 Liège, Belgium
| | - S. Rozenberg
- Department of Gynaecology-Obstetrics, Free University of Brussels, 1090 Brussels, Belgium
| |
Collapse
|
71
|
Dumas V, Ducharne B, Perrier A, Fournier C, Guignandon A, Thomas M, Peyroche S, Guyomar D, Vico L, Rattner A. Extracellular matrix produced by osteoblasts cultured under low-magnitude, high-frequency stimulation is favourable to osteogenic differentiation of mesenchymal stem cells. Calcif Tissue Int 2010; 87:351-64. [PMID: 20582583 DOI: 10.1007/s00223-010-9394-8] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2009] [Accepted: 06/07/2010] [Indexed: 01/28/2023]
Abstract
The effects of low-magnitude, high-frequency (LMHF) mechanical stimulation on osteoblastic cells are poorly understood. We have developed a system that generates very small (15-40 με), high-frequency (400 Hz, sine) deformations on osteoblast cultures (MC3T3-E1). We investigated the effects of these LMHF stimulations mainly on extracellular matrix (ECM) synthesis. The functional properties of this ECM after decellularization were evaluated on C3H10T1/2 mesenchymal stem cells (MSCs). LMHF stimulations were applied 20 min once daily for 1, 3, or 7 days in MC3T3-E1 culture (1, 3, or 7 dLMHF). Cell number and viability were not affected after 3 or 7 dLMHF. Osteoblast response to LMHF was assessed by an increase in nitric oxide secretion, alteration of the cytoskeleton, and focal contacts. mRNA expression for fibronectin, osteopontin, bone sialoprotein, and type I collagen in LMHF cultures were 1.8-, 1.6-, 1.5-, and 1.7-fold higher than controls, respectively (P < 0.05). In terms of protein, osteopontin levels were increased after 3 dLMHF and ECM organization was altered as shown by fibronectin topology after 7 dLMHF. After decellularization, 7 dLMHF-ECM or control ECM was reseeded with MSCs. Seven dLMHF-ECM improved early events such as cell attachment (2 h) and focal contact adhesion (6 h) and, later (16 h), modified MSC morphological parameters. After 5 days in multipotential medium, gene-expression changes indicated that 7 dLMHF-ECM promoted the expression of osteoblast markers at the expense of adipogenic marker. LMHF stimulations of osteoblasts are therefore efficient and sufficient to generate osteogenic matrix.
Collapse
|
72
|
Devkota AC, Weinhold PS. Prostaglandin E(2), collagenase, and cell death responses depend on cyclical load magnitude in an explant model of tendinopathy. Connect Tissue Res 2010; 51:306-13. [PMID: 20175712 DOI: 10.3109/03008200903318261] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Tendinopathy is a significant clinical problem that can result from repetitive activity. While the precise etiology of this condition remains unclear, the cellular response to cyclical loading is believed to have a contributory role to the pathology of tendinopathy. This study examined the short-term biochemical response of avian flexor digitorum profundus tendon to repetitive cyclic loadings of varying magnitude. An in vitro tendon explant model was utilized to apply four levels of haversine tensile stress (peak stress of 0, 3, 12, and 18 MPa) at 1.0 Hz, 8 hr/day for 3 days. The 12 and 18 MPa levels were known to cause significant mechanical damage based on previous work. Tissue media was recovered and analyzed for prostaglandin E(2) (PGE(2)), lactate dehydrogenase (LDH, measure of cell death), and collagenase levels. Tissue samples were recovered and analyzed for cell viability, total collagen, and sulfated glycosaminoglycan content. Collagenase, LDH, and PGE(2) levels were found to be influenced by loading magnitude (p < 0.05) with higher levels being present at higher load magnitudes. Varying cyclical load magnitude caused minimal compositional changes as collagen content and glycosaminoglycan did not change. These results indicate that elevated cyclical mechanical loading of tendon quickly results in altered biochemical tissue responses indicative of tissue injury. More sustained cyclical loading over time may be required for these initial responses to induce more dramatic tissue changes as observed in clinical tendinopathy.
Collapse
Affiliation(s)
- Aaditya C Devkota
- Department of Orthopaedics, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599-7546, USA
| | | |
Collapse
|
73
|
Ahola R, Korpelainen R, Vainionpää A, Jämsä T. Daily impact score in long-term acceleration measurements of exercise. J Biomech 2010; 43:1960-4. [DOI: 10.1016/j.jbiomech.2010.03.021] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2009] [Revised: 03/02/2010] [Accepted: 03/10/2010] [Indexed: 10/19/2022]
|
74
|
Abstract
Aging and a sedentary lifestyle conspire to reduce bone quantity and quality, decrease muscle mass and strength, and undermine postural stability, culminating in an elevated risk of skeletal fracture. Concurrently, a marked reduction in the available bone-marrow-derived population of mesenchymal stem cells (MSCs) jeopardizes the regenerative potential that is critical to recovery from musculoskeletal injury and disease. A potential way to combat the deterioration involves harnessing the sensitivity of bone to mechanical signals, which is crucial in defining, maintaining and recovering bone mass. To effectively utilize mechanical signals in the clinic as a non-drug-based intervention for osteoporosis, it is essential to identify the components of the mechanical challenge that are critical to the anabolic process. Large, intense challenges to the skeleton are generally presumed to be the most osteogenic, but brief exposure to mechanical signals of high frequency and extremely low intensity, several orders of magnitude below those that arise during strenuous activity, have been shown to provide a significant anabolic stimulus to bone. Along with positively influencing osteoblast and osteocyte activity, these low-magnitude mechanical signals bias MSC differentiation towards osteoblastogenesis and away from adipogenesis. Mechanical targeting of the bone marrow stem-cell pool might, therefore, represent a novel, drug-free means of slowing the age-related decline of the musculoskeletal system.
Collapse
|
75
|
Lam H, Brink P, Qin YX. Skeletal nutrient vascular adaptation induced by external oscillatory intramedullary fluid pressure intervention. J Orthop Surg Res 2010; 5:18. [PMID: 20222973 PMCID: PMC2845561 DOI: 10.1186/1749-799x-5-18] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2009] [Accepted: 03/11/2010] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Interstitial fluid flow induced by loading has demonstrated to be an important mediator for regulating bone mass and morphology. It is shown that the fluid movement generated by the intramedullary pressure (ImP) provides a source for pressure gradient in bone. Such dynamic ImP may alter the blood flow within nutrient vessel adjacent to bone and directly connected to the marrow cavity, further initiating nutrient vessel adaptation. It is hypothesized that oscillatory ImP can mediate the blood flow in the skeletal nutrient vessels and trigger vasculature remodeling. The objective of this study was then to evaluate the vasculature remodeling induced by dynamic ImP stimulation as a function of ImP frequency. METHODS Using an avian model, dynamics physiological fluid ImP (70 mmHg, peak-peak) was applied in the marrow cavity of the left ulna at either 3 Hz or 30 Hz, 10 minutes/day, 5 days/week for 3 or 4 weeks. The histomorphometric measurements of the principal nutrient arteries were done to quantify the arterial wall area, lumen area, wall thickness, and smooth muscle cell layer numbers for comparison. RESULTS The preliminary results indicated that the acute cyclic ImP stimuli can significantly enlarge the nutrient arterial wall area up to 50%, wall thickness up to 20%, and smooth muscle cell layer numbers up to 37%. In addition, 3-week of acute stimulation was sufficient to alter the arterial structural properties, i.e., increase of arterial wall area, whereas 4-week of loading showed only minimal changes regardless of the loading frequency. CONCLUSIONS These data indicate a potential mechanism in the interrelationship between vasculature adaptation and applied ImP alteration. Acute ImP could possibly initiate the remodeling in the bone nutrient vasculature, which may ultimately alter blood supply to bone.
Collapse
Affiliation(s)
- Hoyan Lam
- Department of Biomedical Engineering, Stony Brook University, Bioengineering Building Stony Brook, NY 11794, USA
| | | | | |
Collapse
|
76
|
Blecha L, Rakotomanana L, Razafimahery F, Terrier A, Pioletti D. Mechanical interaction between cells and fluid for bone tissue engineering scaffold: Modulation of the interfacial shear stress. J Biomech 2010; 43:933-7. [DOI: 10.1016/j.jbiomech.2009.11.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2009] [Revised: 09/14/2009] [Accepted: 11/01/2009] [Indexed: 11/15/2022]
|
77
|
Lynch MA, Brodt MD, Silva MJ. Skeletal effects of whole-body vibration in adult and aged mice. J Orthop Res 2010; 28:241-7. [PMID: 19658155 PMCID: PMC2929696 DOI: 10.1002/jor.20965] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2009] [Accepted: 06/22/2009] [Indexed: 02/04/2023]
Abstract
Low-amplitude, whole-body vibration (WBV) may be anabolic for bone. Animal studies of WBV have not evaluated skeletal effects in aged animals. We exposed 75 male BALB/c mice (7 month/young-adult; 22 month/aged) to 5 weeks of daily WBV (15 min/day, 5 day/wk; 90 Hz sine wave) at acceleration amplitudes of 0 (sham), 0.3, or 1.0 g. Whole-body bone mineral content (BMC) increased with time in 7 month (p < 0.001) but not 22 month (p = 0.34) mice, independent of WBV (p = 0.60). In 7 month mice, lower-leg BMC increased with time in 0.3 and 1.0 g groups (p < 0.005) but not in the sham group (p = 0.09), indicating a positive WBV effect. In 22 month mice, there were no changes with time in lower-leg BMC (p = 0.11). WBV did not affect tibial trabecular or cortical bone structure (by microCT), dynamic indices of trabecular or cortical bone formation, trabecular osteoclast surface, or the mass of the reproductive fat pad (p > 0.05). Each of these outcomes was diminished in 7 month versus 22 month animals (p < 0.05). In summary, 5 weeks of daily exposure to low-amplitude WBV had no skeletal effects in aged male mice. The potential of WBV to enhance bone mass in age-related osteoporosis is not supported in this preclinical study.
Collapse
Affiliation(s)
- Michelle A. Lynch
- Departments of Orthopaedic Surgery, Washington University, St. Louis, Missouri
| | - Michael D. Brodt
- Departments of Orthopaedic Surgery, Washington University, St. Louis, Missouri
| | - Matthew J. Silva
- Departments of Orthopaedic Surgery, Washington University, St. Louis, Missouri
- Biomedical Engineering, Washington University, St. Louis, Missouri
| |
Collapse
|
78
|
Chen JC, Beaupré GS, Carter DR. An approach to quantifying bone overloading and hypertrophy with applications to multiple experimental studies. Bone 2010; 46:322-9. [PMID: 19800044 DOI: 10.1016/j.bone.2009.09.030] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2009] [Revised: 08/23/2009] [Accepted: 09/23/2009] [Indexed: 10/20/2022]
Abstract
Many studies have investigated mechanically induced bone formation in mice and rats by applying loads to the long bones, and measuring changes in periosteal cortical bone apposition rates. However, the results are difficult to compare among each other because the loading schemes are generally different. The purpose of the present study was to develop a theoretical framework for evaluating the mechanical stimulus based on the bone daily strain stimulus, which is a function of loading cycles and bone strains. The daily strain stimulus would act as a single unifying parameter for directly comparing data from existing in vivo experiments, and is applied here to twenty previous rat and mouse studies. To calculate the daily strain stimulus, we determined the periosteal daily strain stimulus necessary for bone maintenance (xi(peri,0)) and the strain-cycle weighting exponent (m). In the first approach, we applied data from Rubin and Lanyon's bone maintenance studies. We calculated xi(peri,0) to be 2793 microstrain/day, and m to be 4.5. In the second approach, we used Fritton et al. 's strain gage recordings to calculate xi(peri,0) to be 1496 microstrain/day, and used an m value of 11.88, equal to human bone compressive fatigue properties. Fatigue data provided physiological relevance, and was useful for applying an established remodeling theory to in vivo studies. For both approaches, xi(peri,0) was below the fracture level. We then analyzed the applied strains, cycles, and periosteal bone apposition rates from the previous studies. The range of daily strain stimuli calculated using the first approach was much larger than the range using the second approach (2793-17312 microstrain/day compared to 1496-7681 microstrain/day). None of the studies applied a daily strain stimulus above the complete fatigue failure level, but some studies applied loading that could result in major fatigue microdamage. Bone apposition rates generally increased with increasing daily strain stimulus, which was consistent with previous theoretical models. The results suggest that the daily strain stimulus may be a reasonable first approximation for predicting bone apposition rates in a consistent manner. The use of the daily strain stimulus may be helpful for improving the design of future bone loading studies.
Collapse
Affiliation(s)
- J C Chen
- Bone & Joint Rehabilitation R&D Center, VA Palo Alto Health Care System, Palo Alto, CA, USA.
| | | | | |
Collapse
|
79
|
Brouwers JEM, van Rietbergen B, Ito K, Huiskes R. Effects of vibration treatment on tibial bone of ovariectomized rats analyzed by in vivo micro-CT. J Orthop Res 2010; 28:62-9. [PMID: 19603534 DOI: 10.1002/jor.20951] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Daily low-amplitude, high-frequency whole-body vibration (WBV) treatment can increase bone formation rates and bone volume in rodents. Its effects vary, however, with vibration characteristics and study design, and effects on 3D bone microstructure of ovariectomized animals over time have not been documented. Our goal was to determine the effects of WBV on tibial bone of ovariectomized, mature rats over time using an in vivo micro-CT scanner. Adult rats were divided into: ovariectomy (OVX) (n = 8), SHAM-OVX (n = 8), OVX and WBV treatment (n = 7). Eight weeks after OVX, rats in the vibration group were placed on a vibrating platform for 20 min at 0.3 g and 90 Hertz. This was done 5 days a week for six weeks, twice a day. Zero, 8, 10, 12 and 14 weeks after OVX, in vivo micro-CT scans were made (vivaCT 40, Scanco Medical AG) of the proximal and diaphyseal tibia. After sacrifice, all tibiae were dissected and tested in three-point bending. In the metaphysis between 8 to 12 weeks after OVX, WBV treatment did not alter structural parameters compared to the OVX group and both groups continued to show deterioration of bone structure. In the epiphysis, structural parameters were not altered. WBV also did not affect cortical bone and its bending properties. To summarize, no substantial effects of 6 weeks of low-magnitude, high-frequency vibration treatment on tibial bone microstructure and strength in ovariectomized rats were found.
Collapse
Affiliation(s)
- Julienne E M Brouwers
- Department of Biomedical Engineering, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | | | | | | |
Collapse
|
80
|
de Jong WC, Koolstra JH, Korfage JAM, van Ruijven LJ, Langenbach GEJ. The daily habitual in vivo strain history of a non-weight-bearing bone. Bone 2010; 46:196-202. [PMID: 19857616 DOI: 10.1016/j.bone.2009.10.026] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2009] [Revised: 10/14/2009] [Accepted: 10/19/2009] [Indexed: 11/27/2022]
Abstract
Daily mechanical loading strongly influences the architecture and composition of bone tissue. Throughout the day, the amplitudes, rates, frequencies, and the dispersion over time of these loads vary. Nevertheless, most experimental and descriptive studies on the aforementioned relationship consider only cyclic loading and, in addition, focus on weight-bearing bones. A more complete assessment of the daily loading of bone might lead to a better understanding of the natural everyday stimulus for bone maintenance or adaptive responses. In the present study, we measured the daily habitual strain history of the non-weight-bearing mandible bone in the rabbit. Long-term continuous strain recordings were made using an implantable telemetry device able to read out bone-bonded strain gauges. The lateral surface of the rabbit mandibular corpus was chosen as the bone surface of interest. During the recordings, which lasted up to 33 h, the rabbits (N=7) were able to move unrestrictedly in their cages, performing their habitual behaviours. Analysis of the recordings revealed that the measured bone surface was subjected to 2.9 (+/-1.4)x10(3) strain events per hour of which 1.8 (+/-1.0)x10(3) had amplitudes < or =10 microstrains (muvarepsilon). Larger strain amplitudes occurred less often and principal strains fell within the range of -517 (+/-118) muvarepsilon to 298 (+/-81) muvarepsilon. Strain rates never exceeded 10,000 muvarepsilon/s and only 8.9% (+/-7.2%) of the habitual strain rates were higher than 1000 muvarepsilon/s. Strain frequency spectra displayed clear peaks at 4-5 and 9 Hz. The wirelessly recorded daily strain history of the rabbit mandible featured peak strain amplitudes resembling those of other mammalian mandibles, but much smaller than those found in many long-bone strain measurements.
Collapse
Affiliation(s)
- W C de Jong
- Department of Functional Anatomy, Academic Centre for Dentistry Amsterdam (ACTA), Research Institute MOVE, University of Amsterdam and VU University Amsterdam, Meibergdreef 15, 1105 AZ Amsterdam, The Netherlands.
| | | | | | | | | |
Collapse
|
81
|
Lin D, Li Q, Li W, Swain M. Dental implant induced bone remodeling and associated algorithms. J Mech Behav Biomed Mater 2009; 2:410-32. [DOI: 10.1016/j.jmbbm.2008.11.007] [Citation(s) in RCA: 113] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2007] [Revised: 11/28/2008] [Accepted: 11/30/2008] [Indexed: 11/30/2022]
|
82
|
Roberts MD, Santner TJ, Hart RT. Local bone formation due to combined mechanical loading and intermittent hPTH-(1-34) treatment and its correlation to mechanical signal distributions. J Biomech 2009; 42:2431-8. [PMID: 19782988 DOI: 10.1016/j.jbiomech.2009.08.030] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2004] [Revised: 08/10/2009] [Accepted: 08/19/2009] [Indexed: 11/16/2022]
Abstract
We evaluated the local response of cortical bone in the rat tibia due to combined treatment with synthetic parathyroid hormone, hPTH-(1-34), and mechanical stimulation by four-point bending. Forty-eight female retired breeder Sprague-Dawley rats were divided into six groups. Mechanically stimulated animals included the following groups: (1) Bend+PTH, (2) Sham+PTH, (3) Bend+Vehicle, (4) Sham+Vehicle. Non-mechanically stimulated animals included a (5) Control group that received neither loading nor injections, and a (6) PTH group that received only hPTH-(1-34) injections. The right limbs of mechanically loaded animals were exposed to a peak force of 50 N for 36 cycles at 2 Hz, three days per week for four weeks, and PTH-treated animals received injections equivalent to 50 microg/kg BW. Fluorochrome labeling was used to measure local formation at 12 sectors about the endocortical periphery. The distributions of endocortical bone formation were compared to the local formation differences between treatment groups and to a variety of potential mechanical stimuli signals. Results indicated that hPTH-(1-34) exerted a potent anabolic effect with near-uniform formation about the endocortical surface, and that localized formation peaks due to bending were further augmented in the presence of hPTH-(1-34) treatment. Correlation of formation patterns to mechanical signal distributions highlighted several candidate signals including the mid-principal stress, the dilatational strain, and the radial gradient of the local radial strain.
Collapse
Affiliation(s)
- M D Roberts
- Department of Biomedical Engineering, Tulane University, New Orleans, LA, USA
| | | | | |
Collapse
|
83
|
Shaw CN, Stock JT. Intensity, repetitiveness, and directionality of habitual adolescent mobility patterns influence the tibial diaphysis morphology of athletes. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY 2009; 140:149-59. [DOI: 10.1002/ajpa.21064] [Citation(s) in RCA: 156] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
84
|
Abstract
OBJECTIVES Response of the skeleton to application and removal of specific mechanical signals is discussed. Anabolic effects of high-frequency, low-magnitude vibrations, a mechanical intervention with a favorable safety profile, as well as the modulation of bone loss by genetic and epigenetic factors during disuse are highlighted. METHODS Review. RESULTS Bone responds to a great variety of mechanical signals and both high- and low-magnitude stimuli can be sensed by the skeleton. The ability of physical signals to influence bone morphology is strongly dependent on the signal's magnitude, frequency, and duration. Loading protocols at high signal frequencies (vibrations) allow a dramatic reduction in the magnitude of the signal. In the axial skeleton, these signals can be anabolic and anti-catabolic and increase the structural strength of the tissue. They further have shown potential in maxillofacial applications to accelerate the regeneration of bone within defects. Bone's sensitivity to the application and removal of mechanical signals is heavily under the control of the genome. Bone loss modulated by the removal of weight-bearing from the skeleton is profoundly influenced by factors such as genetics, gender, and baseline morphology. CONCLUSIONS Adaptation of bone to functional challenges is complex but it is clear that more is not necessarily better and that even very low-magnitude mechanical signals can be anabolic. The development of effective biomechanical interventions in areas such as orthodontics, craniofacial repair, or osteoporosis will require the identification of the specific components of bone's mechanical environment that are anabolic, catabolic, or anti-catabolic.
Collapse
Affiliation(s)
- S Judex
- Department of Biomedical Engineering, State University of New York at Stony Brook, Stony Brook, NY 11794-2580, USA
| | | | | |
Collapse
|
85
|
Demes B, Carlson KJ. Locomotor variation and bending regimes of capuchin limb bones. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY 2009; 139:558-71. [DOI: 10.1002/ajpa.21020] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
86
|
Sriram D, Jones A, Alatli-Burt I, Darendeliler MA. Effects of mechanical stimuli on adaptive remodeling of condylar cartilage. J Dent Res 2009; 88:466-70. [PMID: 19493892 DOI: 10.1177/0022034509336616] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Trabecular bone has been shown to be responsive to low-magnitude, high-frequency mechanical stimuli. This study aimed to assess the effects of these stimuli on condylar cartilage and its endochondral bone. Forty female 12-week-old C3H mice were divided into 3 groups: baseline control (killed at day 0), sham (killed at day 28 without exposure to mechanical stimuli), and experimental (killed following 28 days of exposure to mechanical stimuli). The experimental group was subjected to mechanical vibration of 30 Hz, for 20 minutes per day, 5 days per week, for 28 days. The specimens were analyzed by micro-computed tomography. The experimental group demonstrated a significant decrease in the volume of condylar cartilage and also a significant increase in bone histomorphometric parameters. The results suggest that the low-magnitude, high-frequency mechanical stimuli enhance adaptive remodeling of condylar cartilage, evidenced by the advent of endochondral bone replacing the hypertrophic cartilage.
Collapse
Affiliation(s)
- D Sriram
- Discipline of Orthodontics, Faculty of Dentistry, Sydney Dental Hospital, The University of Sydney, 2 Chalmers Street, Surry Hills, NSW 2010, Australia
| | | | | | | |
Collapse
|
87
|
Leung KS, Shi HF, Cheung WH, Qin L, Ng WK, Tam KF, Tang N. Low-magnitude high-frequency vibration accelerates callus formation, mineralization, and fracture healing in rats. J Orthop Res 2009; 27:458-65. [PMID: 18924140 DOI: 10.1002/jor.20753] [Citation(s) in RCA: 84] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Fracture healing is a biological regenerative process that follows a well-orchestrated sequence. Most healing is uneventful and enhancement of normal fracture healing is not commonly done, although it is clinically important in the recovery and regain of functions after fracture. This study investigated the osteogenic effect of low-magnitude high-frequency vibration (LMHFV, 35 Hz, 0.3 g) on the enhancement of fracture healing in rats with closed femoral shaft fracture by comparing with sham-treated control. Assessments with plain radiography, micro-CT as well as histomorphometry showed that the amount of callus was significantly larger (p = 0.001 for callus area, 2 weeks posttreatment); the remodeling of the callus into mature bone was significantly faster (p = 0.039, 4 weeks posttreatment) in the treatment group. The mechanical strength of the healed fracture in the treatment group at 4 weeks was significantly greater (p < 0.001). The results showed the acceleration of callus formation, mineralization, and fracture healing in the treatment group. It is concluded that LMHFV enhances healing in the closed femoral shaft fracture in rats. The potential clinical advantages shall be confirmed in the subsequent clinical trials.
Collapse
Affiliation(s)
- Kwok Sui Leung
- Department of Orthopaedics and Traumatology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, People's Republic of China.
| | | | | | | | | | | | | |
Collapse
|
88
|
Luu YK, Pessin JE, Judex S, Rubin J, Rubin CT. Mechanical Signals As a Non-Invasive Means to Influence Mesenchymal Stem Cell Fate, Promoting Bone and Suppressing the Fat Phenotype. ACTA ACUST UNITED AC 2009; 6:132-149. [PMID: 22241295 DOI: 10.1138/20090371] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Pluripotent mesenchymal stem cells (MSCs) are considered ideal therapeutic targets in regenerative medicine, as they hold the capacity to differentiate into higher order connective tissues. The potential to harness MSCs for disease treatment and acceleration of repair will ultimately depend on an improved understanding of how physical and/or chemical signals regulate their activity, and the ability of exogenous stimuli to enhance MSC proliferation and define MSC fate. Recent appreciation that bone marrow osteoprogenitors are inversely proportional to adipocyte precursors suggests that their shared progenitor, the MSC, will commit to one lineage at the cost of the other. This interrelationship may contribute to the phenotype of sedentary subjects who have more fat and less bone, while conversely, to the outcome of exercise being less fat and more bone. Mechanical biasing of MSC lineage selection suggests that physical signals may influence the quantity of both fat and bone through developmental, as well as metabolic or adaptive pathways. Considered with the recent finding that low magnitude mechanical signals (LMMS) suppress the development of subcutaneous and visceral fat without elevating energy expenditure, this indicates that MSCs are ideally positioned as mechanosensitive elements central to musculoskeletal adaptation, but that the signals needn't be large to be influential. The biasing of MSC differentiation by mechanical signals represents a unique means by which adiposity can be inhibited while simultaneously promoting a better skeleton, and may provide the basis for a safe, non-invasive, non-pharmacologic strategy to prevent both obesity and osteoporosis, yet uniquely - without targeting the resident fat or bone cell.
Collapse
Affiliation(s)
- Yen K Luu
- Diabetes Research Center, Department of Medicine, Division of Endocrinology, Albert Einstein College of Medicine, Bronx, NY, USA
| | | | | | | | | |
Collapse
|
89
|
Mavroeidi A, Stewart AD, Reid DM, Macdonald HM. Physical activity and dietary calcium interactions in bone mass in Scottish postmenopausal women. Osteoporos Int 2009; 20:409-16. [PMID: 18633668 DOI: 10.1007/s00198-008-0681-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2008] [Accepted: 05/29/2008] [Indexed: 10/21/2022]
Abstract
UNLABELLED In this population-based cohort of 1,254 older Scottish women we found significant interactions between the mechanical component of self-reported habitual physical activity (PA) and dietary calcium (Ca) in BMD, independent of other risk factors. At low and/or medium Ca intakes BMD was higher amongst the most active people. INTRODUCTION Although there is general agreement that increased activity (PA) and dietary calcium (Ca) consumption may help maintain bone mass in later life and prevent fractures, the amount required remains uncertain. METHODS In 2001-2003, 1,847 postmenopausal women (mean +/- SD age: 69.3 +/- 5.5 years) underwent bone mineral density (BMD) measurement and, in 2004, 68.7% (n = 1,254) completed a bone-specific Physical Activity Questionnaire (bsPAQ) and a food frequency questionnaire. The bsPAQ measures the metabolic and mechanical components of PA. Interactions of PA and Ca in BMD were examined using ANCOVA. RESULTS Significant interactions were identified in the BMD of the lumbar spine (LS), right hip (RH) and left hip (LH), after adjustment for confounders, between tertiles of PA classified according to the mechanical component and tertiles of energy-adjusted Ca intake (ANCOVA p = 0.006, p = 0.004 and p = 0.013 respectively). For example, at medium Ca intakes LH BMD was higher by 7.8% in the highest tertile of PA compared with the lowest tertile of PA. CONCLUSIONS These data suggest that health promotion campaigns to increase PA would be most effective in populations with a low/medium calcium intake.
Collapse
Affiliation(s)
- A Mavroeidi
- School of Medical Sciences, University of Aberdeen, Aberdeen, UK.
| | | | | | | |
Collapse
|
90
|
Hanson AD, Marvel SW, Bernacki SH, Banes AJ, van Aalst J, Loboa EG. Osteogenic effects of rest inserted and continuous cyclic tensile strain on hASC lines with disparate osteodifferentiation capabilities. Ann Biomed Eng 2009; 37:955-65. [PMID: 19229619 DOI: 10.1007/s10439-009-9648-7] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2008] [Accepted: 02/04/2009] [Indexed: 01/22/2023]
Abstract
We investigated the effects of two types of cyclic tensile strain, continuous and rest inserted, on osteogenic differentiation of human adipose-derived adult stem cells (hASCs). The influence of these mechanical strains was tested on two hASC lines having different mineral deposition potential, with one cell line depositing approximately nine times as much calcium as the other hASC line after 14 days of culture in osteogenic medium on tissue culture plastic. Results showed that both continuous (10% strain, 1 Hz) and rest inserted cyclic tensile strain (10% strain, 1 Hz, 10 s rest after each cycle) regimens increased the amount and rate of calcium deposition for both high and low calcium depositing hASC lines as compared to unstrained controls. The response was similar for both types of tensile strain for a given cell line, however, cyclic tensile strain had a much stronger osteogenic effect on the high calcium depositing hASC line, suggesting that mechanical loading has a greater effect on cell lines that already have an innate ability to produce bone as compared to cell lines that do not. This is the first study to investigate the osteodifferentiation effects of cyclic tensile strain on hASCs and the first to show that both continuous (10%, 1 Hz) and rest inserted (10%, 1 Hz, 10 s rest) cyclic tensile strain accelerate hASC osteodifferentiation and increase calcium accretion.
Collapse
Affiliation(s)
- Ariel D Hanson
- Joint Department of Biomedical Engineering, North Carolina State University and UNC-Chapel Hill, 2142 Burlington Laboratories, Campus Box 7115, Raleigh, NC 27695-7115, USA
| | | | | | | | | | | |
Collapse
|
91
|
Qin YX, Lam H. Intramedullary pressure and matrix strain induced by oscillatory skeletal muscle stimulation and its potential in adaptation. J Biomech 2009; 42:140-5. [PMID: 19081096 PMCID: PMC2975034 DOI: 10.1016/j.jbiomech.2008.10.018] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2008] [Revised: 09/04/2008] [Accepted: 10/13/2008] [Indexed: 11/15/2022]
Abstract
Intramedullary pressure (ImP) and low-level bone strain induced by oscillatory muscle stimulation (MS) has the potential to mitigate bone loss induced by disuse osteopenia, i.e., hindlimb suspension (HLS). To test this hypothesis, we evaluated (a) MS-induced ImP and bone strain as function of stimulation frequency and (b) the adaptive responses to functional disuse, and disuse plus 1 and 20 Hz stimulation in vivo. Femoral ImP and bone strain generated by MS were measured in the frequencies of 1-100 Hz in four rats. Forty retired breeder rats were used for the in vivo HLS study. The quadriceps muscle was stimulated at frequencies of 1 and 20 Hz, 10 min/d for four weeks. The metaphyseal trabecular bone quantity and microstructure at the distal femur were evaluated using microCT, while bone formation indices were analyzed using histomorphometric technique. Oscillatory MS generated a maximum ImP of 45+/-9 mmHg at 20 Hz and produced a maximum matrix strain of 128+/-19 microepsilon at 10 Hz. Our analyses from the in vivo study showed that MS at 20 Hz was able to attenuate trabecular bone loss and partially maintain the microstructure induced by HLS. Conversely, there was no evidence of an adaptive effect of stimulation at 1 Hz on disused skeleton. The results suggested that oscillatory MS regulates fluid dynamics and mechanical strain in bone, which serves as a critical mediator of adaptation. These results clearly demonstrated the ability of MS in attenuating bone loss from the disuse osteopenia, which may hold potential in mitigating skeletal degradation imposed by conditions of disuse, and may serve as a biomechanical intervention in clinic application.
Collapse
Affiliation(s)
- Yi-Xian Qin
- Department of Biomedical Engineering, State University of New York at Stony Brook, 350 Psychology-A Building, Stony Brook, NY 11794-2580, USA.
| | | |
Collapse
|
92
|
Lam H, Qin YX. The effects of frequency-dependent dynamic muscle stimulation on inhibition of trabecular bone loss in a disuse model. Bone 2008; 43:1093-100. [PMID: 18757047 PMCID: PMC2642608 DOI: 10.1016/j.bone.2008.07.253] [Citation(s) in RCA: 70] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2008] [Revised: 07/24/2008] [Accepted: 07/30/2008] [Indexed: 10/21/2022]
Abstract
Clinical electrical muscle stimulation has been shown to alleviate muscle atrophy resulting from functional disuse, yet little is known about its effect on the skeleton. The objective of this study is to evaluate the potential of dynamic muscle stimulation on disused trabecular bone, and to investigate the importance of optimized stimulation frequency in the loading regimen. Fifty-six skeletally mature Sprague-Dawley rats were divided into seven groups for the 4-week experiment: baseline control, age-matched control, hindlimb suspended (HLS), and HLS with muscle stimulation at 1 Hz, 20 Hz, 50 Hz, and 100 Hz. Muscle stimulation was carried out for 10 min per day for 5 days per week, total of 4 weeks. The metaphyseal and epiphyseal trabecular regions of the distal femurs were analyzed with microcomputed tomography and histomorphometry methods. HLS alone for 4-week resulted in a significant amount of trabecular bone loss and structural deterioration. Muscle contraction at 1 Hz was not sufficient to inhibit trabecular bone loss and resulted in similar amount of loss to that of HLS alone. Bone quantity and structure were significantly improved by applying muscle stimulation at mid-frequency (20 Hz and 50 Hz). Dynamic stimulation at 50 Hz demonstrated the greatest preventive effect on the skeleton against functional disused alone animals (up to +147% in bone volume fraction, +38% in trabecular number and -36% in trabecular separation). Histomorphometric analysis showed that the stimulation, regardless of its frequency, did not have an effect on the bone formation indices, such as mineral apposition rate and bone formation rate. Overall, the data demonstrated the potentials of frequency-dependent dynamic muscle contraction in regulating skeletal adaptive responses under disuse conditions. Dynamic muscle stimulation, with a specific regimen, may be beneficial to future orthopedic research in developing a countermeasure for disuse osteopenia and osteoporosis.
Collapse
Affiliation(s)
- Hoyan Lam
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794-2580
| | - Yi-Xian Qin
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794-2580
| |
Collapse
|
93
|
Kecskemethy HH, Herman D, May R, Paul K, Bachrach SJ, Henderson RC. Quantifying weight bearing while in passive standers and a comparison of standers. Dev Med Child Neurol 2008; 50:520-3. [PMID: 18611202 DOI: 10.1111/j.1469-8749.2008.03021.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Mechanical loading plays an important role in skeletal health, and this is a major reason standing devices are widely used with non-ambulatory persons. However, little is known about the true axial loading that occurs while in a stander, or the factors which may impact loading. The purpose of this study was to quantify weight borne while in a stander, and to directly compare different standers. Load measuring footplate adaptors were designed and fabricated specifically for this study. Weight bearing loads in 20 non-ambulatory persons with quadriplegic cerebral palsy aged 6 to 21 years (median 14 y) were continuously monitored during routine 30-minute standing sessions. Fourteen participants were female, six were male; one was Gross Motor Function Classification System (GMFCS) Level IV, and 19 were GMFCS Level V. Each participant was monitored on four to six occasions over an 8-week period, two to three times in each of two different standers (total 108 standing sessions). Weight bearing loads ranged widely from 37 to 101% of body weight. The difference between standers was as much as 29% body weight. There is wide variance in the actual weight borne while in passive standers. The type of stander utilized is one factor which can significantly affect the amount of weight borne.
Collapse
Affiliation(s)
- Heidi H Kecskemethy
- Nemours Biomedical Research, Nemours/AI duPont Hospital for Children, Wilmington, DE, U.S.A
| | | | | | | | | | | |
Collapse
|
94
|
Ozcivici E, Garman R, Judex S. High-frequency oscillatory motions enhance the simulated mechanical properties of non-weight bearing trabecular bone. J Biomech 2007; 40:3404-11. [PMID: 17655852 DOI: 10.1016/j.jbiomech.2007.05.015] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2007] [Revised: 04/17/2007] [Accepted: 05/15/2007] [Indexed: 11/17/2022]
Abstract
Extremely low-level oscillatory accelerations, applied without constraint, can increase bone formation. Here, we tested the hypothesis that high-frequency oscillations, applied in the absence of functional weight bearing, can be sensed by trabecular bone to produce a structure that is more efficient in sustaining applied loads. The left leg of anesthetized adult female mice (n=18) was subjected to high-frequency oscillations at 45 Hz, 0.6g for 20 min/day, 5 days/week for 3 weeks, while the contralateral leg served as an internal control. To remove the potential interference of the habitual strain environment with the imposed physical signal, the hindlimbs of these mice were chronically unloaded. In vivo microCT scans of the proximal metaphyseal region of the tibia were transformed into finite element meshes to evaluate trabecular and cortical mechanical properties. Simulated longitudinal compression tests showed that the short applications of high-frequency oscillations were sensed primarily by trabecular bone. At the end of the experimental period, apparent trabecular stiffness of the oscillated bones was 38% (p<0.001) greater than that of non-weight bearing controls. Simulated uniaxial loads applied to trabecular bone induced 21%, 52%, and 131% greater (p<0.05) median, peak compressive, and peak tensile longitudinal stresses in control than in stimulated bones. Non-weight bearing control bones were also characterized by greater transverse normal and shear stresses (77% and 54%, respectively, p<0.001) as well as 35% greater (p=0.03) longitudinal shear stresses. Compared to normal age-matched controls (n=18), oscillations were able to attenuate, but not fully prevent, the decline in trabecular mechanical properties associated with the removal of weight bearing. These data indicate not only that bone cells can sense low-level, high-frequency oscillatory accelerations, but also that they can orchestrate a structural response that produces a stiffer trabecular structure that may be less prone to fracture.
Collapse
Affiliation(s)
- Engin Ozcivici
- Department of Biomedical Engineering, Psychology A Building, 3rd Floor, State University of New York at Stony Brook, Stony Brook, NY 11794-2580, USA
| | | | | |
Collapse
|
95
|
Muir P, Sample SJ, Barrett JG, McCarthy J, Vanderby R, Markel MD, Prokuski LJ, Kalscheur VL. Effect of fatigue loading and associated matrix microdamage on bone blood flow and interstitial fluid flow. Bone 2007; 40:948-56. [PMID: 17234467 DOI: 10.1016/j.bone.2006.11.012] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2006] [Revised: 10/28/2006] [Accepted: 11/09/2006] [Indexed: 10/23/2022]
Abstract
Functional adaptation of bone to cyclic fatigue involves a complex physiological response that is targeted to sites of microdamage. The mechanisms that regulate this process are not understood, although lacunocanalicular interstitial fluid flow is likely important. We investigated the effect of a single period of cyclic fatigue on bone blood flow and interstitial fluid flow. The ulnae of 69 rats were subjected to cyclic fatigue unilaterally using an initial peak strain of -6000 muepsilon until 40% loss of stiffness developed. Groups of rats (n=23 per group) were euthanized immediately after loading, at 5 days, and at 14 days. The contralateral ulna served as a treatment control, and a baseline control group (n=23) that was not loaded was also included. After euthanasia, localization of intravascular gold microspheres within the ulna (n=7 rats/group) and tissue distribution of procion red tracer were quantified (n=8 rats/group). Microcracking, modeling, and remodeling (Cr.S.Dn, microm/mm(2), Ne.Wo.B.T.Ar, mm(2), and Rs.N/T.Ar, #/mm(2) respectively) were also quantified histologically (n=8 rats/group). Cyclic fatigue loading induced hyperemia of the loaded ulna, which peaked at 5 days after loading. There was an associated overall decrease in procion tracer uptake in both the loaded and contralateral control ulnae. Tracer uptake was also decreased in the periosteal region, when compared with the endosteal region of the cortex. Pooling of tracer was seen in microdamaged bone typically adjacent to an intracortical stress fracture at all time points after fatigue loading; in adjacent bone tracer uptake was decreased. New bone formation was similar at 5 days and at 14 days, whereas formation of resorption spaces was increased at 14 days. These data suggest that a short period of cyclic fatigue induces bone hyperemia and associated decreased lacunocanalicular interstitial fluid flow, which persists over the time period in which osteoclasts are recruited to sites of microdamage for targeted remodeling. Matrix damage and development of stress fracture also interfere with normal centrifugal fluid flow through the cortex. Changes in interstitial fluid flow in the contralateral ulna suggest that functional adaptation to unilateral fatigue loading may include a more generalized neurovascular response.
Collapse
Affiliation(s)
- Peter Muir
- Comparative Orthopaedic Research Laboratory, School of Veterinary Medicine, 2015 Linden Drive, Madison, WI 53706, USA.
| | | | | | | | | | | | | | | |
Collapse
|
96
|
Srinivasan S, Ausk BJ, Poliachik SL, Warner SE, Richardson TS, Gross TS. Rest-inserted loading rapidly amplifies the response of bone to small increases in strain and load cycles. J Appl Physiol (1985) 2007; 102:1945-52. [PMID: 17255366 DOI: 10.1152/japplphysiol.00507.2006] [Citation(s) in RCA: 69] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
We hypothesized that a 10-s rest interval (at zero load) inserted between each load cycle would increase the osteogenic effects of mechanical loading near previously identified thresholds for strain magnitude and cycle numbers. We tested our hypothesis by subjecting the right tibiae of female C57BL/6J mice (16 wk, n = 70) to exogenous mechanical loading within a peri-threshold physiological range of strain magnitudes and load cycle numbers using a noninvasive murine tibia loading device. Bone responses to mechanical loading were determined via dynamic histomorphometry. More specifically, we contrasted bone formation induced by cyclic vs. rest-inserted loading (10-s rest at zero load inserted between each load cycle) by first varying peak strains (1,000, 1,250, or 1,600 micro epsilon) at fixed cycle numbers (50 cycles/day, 3 days/wk for 3 wk) and then varying cycle numbers (10, 50, or 250 cycles/day) at a fixed strain magnitude (1,250 micro epsilon). Within the range of strain magnitudes tested, the slope of periosteal bone formation rate (p.BFR/BS) with increasing strain magnitudes was significantly increased by rest-inserted compared with cyclical loading. Within the range of load cycles tested, the slope of p.BFR/BS with increasing load cycles of rest-inserted loading was also significantly increased by rest-inserted compared with cyclical loading. In sum, the data of this study indicate that inserting a 10-s rest interval between each load cycle amplifies bone's response to mechanical loading, even within a peri-threshold range of strain magnitudes and cycle numbers.
Collapse
Affiliation(s)
- Sundar Srinivasan
- Dept. of Orthopaedics, University of Washington, Seattle, WA 98104-2499, USA.
| | | | | | | | | | | |
Collapse
|
97
|
Abstract
PURPOSE Children who are nonambulatory are placed into standers with the goal of providing benefits from weight-bearing. The purpose of this study was to quantify weight-bearing loads by children with cerebral palsy while in standers. METHODS Electronic load-measuring footplates were fabricated specifically for this study. Weight-bearing loads were continuously measured in 19 children who were nonambulatory during routine 30-minute standing sessions (3-6 sessions/child, total 110 sessions). RESULTS Weight-bearing ranged widely (23%-102%) with a mean of 68% of body weight. There was some variation over the course of a session and between different sessions, but more variance was noted between subjects. CONCLUSIONS Actual weight borne in a stander is quite variable, and in some instances only a fraction of actual body weight. Further studies are required to delineate relevant factors and identify ways to maximize weight-bearing loads while in a stander.
Collapse
|
98
|
Zernicke R, MacKay C, Lorincz C. Mechanisms of bone remodeling during weight-bearing exercise. Appl Physiol Nutr Metab 2006; 31:655-60. [PMID: 17213879 DOI: 10.1139/h06-051] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Exercise-induced mechanical loading can have potent effects on skeletal form and health. Both intrinsic and extrinsic factors contribute to bone structure and function. Mechanical simuli (e.g., strain magnitude, frequency, rate, and gradients, as well as fluid flow and shear stress) have potent influences on bone-cell cytoskeleton and associated signalling pathways. Although the immature skeleton may be more able to benefit from exercise, a skeletally mature population can also benefit from exercise programs aimed at increasing the functional loads to which the skeleton is exposed. The definitive explanation of mechanical-loading and (or) bone-cell mechanotransductive phenomena, however, remains elusive. Here, we briefly review the structural and anatomical foundation for bone adaptation, focusing on mechanical loading effects on bone, linked to the roles of integrins, cytoskeleton, membrane channels, and auto- and paracrine factors in bone modeling and remodeling.
Collapse
Affiliation(s)
- Ronald Zernicke
- Faculty of Kinesiology, University of Calgary, 2500 University Drive NW, Calgary, AB T2N 1N4, Canada.
| | | | | |
Collapse
|
99
|
Judex S, Lei X, Han D, Rubin C. Low-magnitude mechanical signals that stimulate bone formation in the ovariectomized rat are dependent on the applied frequency but not on the strain magnitude. J Biomech 2006; 40:1333-9. [PMID: 16814792 DOI: 10.1016/j.jbiomech.2006.05.014] [Citation(s) in RCA: 193] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2005] [Accepted: 05/15/2006] [Indexed: 10/24/2022]
Abstract
There is growing evidence that extremely small mechanical signals, if applied at a sufficiently high frequency, can serve as anabolic signals to bone tissue. To determine if the responsiveness of bone to low-magnitude, high-frequency parameters is modulated by endocrine imbalance, ovariectomized (OVX) Sprague-Dawley rats were subjected to whole body vibrations (WBV, 0.15 g) at 45 Hz (n=6) or 90 Hz (n=6) for 10 min/day, and compared to OVX age-matched controls (n=6). Five additional rats were used, in vivo, to establish the induced bone surface strain magnitudes (and strain rates). Following a 28 d protocol, bone formation rates in the metaphysis of the proximal tibia were 159% greater in 90 Hz rats when compared to age-matched controls, but 45 Hz rats were not significantly different from controls. Bone morphology of 90 Hz rats indicated significantly greater trabecular bone volume (22% and 25%) and thicker trabeculae (11% and 12%) over either controls or 45 Hz rats in the epiphysis of the distal femur, respectively. Despite the enhanced sensitivity of the skeleton towards the 90 Hz signal, the strain magnitudes and strain rates induced by this frequency were significantly lower than during 45 Hz vibration, suggesting that factors other than matrix strain are driving the anabolic response. Ideally, such mechanical signals represent a non-pharmacologic means of controlling bone mass and morphology in spite of systemic pressures for bone resorption.
Collapse
Affiliation(s)
- Stefan Judex
- Department of Biomedical Engineering, State University of New York at Stony Brook, Stony Brook, NY, USA.
| | | | | | | |
Collapse
|
100
|
Rubin J, Rubin C, Jacobs CR. Molecular pathways mediating mechanical signaling in bone. Gene 2006; 367:1-16. [PMID: 16361069 PMCID: PMC3687520 DOI: 10.1016/j.gene.2005.10.028] [Citation(s) in RCA: 309] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2005] [Accepted: 10/03/2005] [Indexed: 12/26/2022]
Abstract
Bone tissue has the capacity to adapt to its functional environment such that its morphology is "optimized" for the mechanical demand. The adaptive nature of the skeleton poses an interesting set of biological questions (e.g., how does bone sense mechanical signals, what cells are the sensing system, what are the mechanical signals that drive the system, what receptors are responsible for transducing the mechanical signal, what are the molecular responses to the mechanical stimuli). Studies of the characteristics of the mechanical environment at the cellular level, the forces that bone cells recognize, and the integrated cellular responses are providing new information at an accelerating speed. This review first considers the mechanical factors that are generated by loading in the skeleton, including strain, stress and pressure. Mechanosensitive cells placed to recognize these forces in the skeleton, osteoblasts, osteoclasts, osteocytes and cells of the vasculature are reviewed. The identity of the mechanoreceptor(s) is approached, with consideration of ion channels, integrins, connexins, the lipid membrane including caveolar and non-caveolar lipid rafts and the possibility that altering cell shape at the membrane or cytoskeleton alters integral signaling protein associations. The distal intracellular signaling systems on-line after the mechanoreceptor is activated are reviewed, including those emanating from G-proteins (e.g., intracellular calcium shifts), MAPKs, and nitric oxide. The ability to harness mechanical signals to improve bone health through devices and exercise is broached. Increased appreciation of the importance of the mechanical environment in regulating and determining the structural efficacy of the skeleton makes this an exciting time for further exploration of this area.
Collapse
Affiliation(s)
- Janet Rubin
- Department of Medicine, VAMC and Emory University School of Medicine, Atlanta GA, VAMC-151, 1670 Clairmont Rd, Decatur, GA 30033, USA.
| | | | | |
Collapse
|