51
|
Mochalski P, Unterkofler K, Španěl P, Smith D, Amann A. Product ion distributions for the reactions of NO(+) with some physiologically significant volatile organosulfur and organoselenium compounds obtained using a selective reagent ionization time-of-flight mass spectrometer. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2014; 28:1683-1690. [PMID: 24975248 PMCID: PMC4142009 DOI: 10.1002/rcm.6947] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/04/2014] [Revised: 05/09/2014] [Accepted: 05/13/2014] [Indexed: 06/03/2023]
Abstract
RATIONALE The reactions of NO(+) with volatile organic compounds (VOCs) in Selective Reagent Ionization Time-of-Flight Mass Spectrometry (SRI-TOF-MS) reactors are relatively poorly known, inhibiting their use for trace gas analysis. The rationale for this product ion distribution study was to identify the major product ions of the reactions of NO(+) ions with 13 organosulfur compounds and 2 organoselenium compounds in an SRI-TOF-MS instrument and thus to prepare the way for their analysis in exhaled breath, in skin emanations and in the headspace of urine, blood and cell and bacterial cultures. METHODS Product ion distributions have been investigated by a SRI-TOF-MS instrument at an E/N in the drift tube reactor of 130 Td for both dry air and humid air (4.9% absolute humidity) used as the matrix gas. The investigated species were five monosulfides (dimethyl sulfide, ethyl methyl sulfide, methyl propyl sulfide, allyl methyl sulfide and methyl 5-methyl-2-furyl sulfide), dimethyl disulfide, dimethyl trisulfide, thiophene, 2-methylthiophene, 3-methylthiophene, methanethiol, allyl isothiocyanate, dimethyl sulfoxide, and two selenium compounds - dimethyl selenide and dimethyl diselenide. RESULTS Charge transfer was seen to be the dominant reaction mechanism in all reactions under study forming the M(+) cations. For methanethiol and allyl isothiocyanate significant fractions were also observed of the stable adduct ions NO(+) M, formed by ion-molecule association, and [M-H](+) ions, formed by hydride ion transfer. Several other minor product channels are seen for most reactions indicating that the nascent excited intermediate (NOM)(+) * adduct ions partially fragment along other channels, most commonly by the elimination of neutral CH3 , CH4 and/or C2 H4 species that are probably bound to an NO molecule. Humidity had little effect on the product ion distributions. CONCLUSIONS The findings of this study are of particular importance for data interpretation in studies of volatile organosulfur and volatile organoselenium compounds employing SRI-TOF-MS in the NO(+) mode.
Collapse
Affiliation(s)
- Paweł Mochalski
- Breath Research Institute of the University of InnsbruckRathausplatz 4, A-6850, Dornbirn, Austria
| | - Karl Unterkofler
- Breath Research Institute of the University of InnsbruckRathausplatz 4, A-6850, Dornbirn, Austria
- Vorarlberg University of Applied SciencesHochschulstr. 1, A-6850, Dornbirn, Austria
| | - Patrik Španěl
- J. Heyrovský Institute of Physical Chemistry, Academy of Sciences of the Czech RepublicDolejškova 3, 18223, Prague 8, Czech Republic
| | - David Smith
- Institute for Science and Technology in Medicine, Medical School, Keele UniversityThornburrow Drive, Hartshill, Stoke-on-Trent, ST4 7QB, UK
| | - Anton Amann
- Breath Research Institute of the University of InnsbruckRathausplatz 4, A-6850, Dornbirn, Austria
- Univ.-Clinic for Anesthesia and Intensive Care, Innsbruck Medical UniversityAnichstr, 35, A-6020, Innsbruck, Austria
| |
Collapse
|
52
|
Lourenço C, Turner C. Breath analysis in disease diagnosis: methodological considerations and applications. Metabolites 2014; 4:465-98. [PMID: 24957037 PMCID: PMC4101517 DOI: 10.3390/metabo4020465] [Citation(s) in RCA: 141] [Impact Index Per Article: 14.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2014] [Revised: 06/02/2014] [Accepted: 06/09/2014] [Indexed: 02/07/2023] Open
Abstract
Breath analysis is a promising field with great potential for non-invasive diagnosis of a number of disease states. Analysis of the concentrations of volatile organic compounds (VOCs) in breath with an acceptable accuracy are assessed by means of using analytical techniques with high sensitivity, accuracy, precision, low response time, and low detection limit, which are desirable characteristics for the detection of VOCs in human breath. "Breath fingerprinting", indicative of a specific clinical status, relies on the use of multivariate statistics methods with powerful in-built algorithms. The need for standardisation of sample collection and analysis is the main issue concerning breath analysis, blocking the introduction of breath tests into clinical practice. This review describes recent scientific developments in basic research and clinical applications, namely issues concerning sampling and biochemistry, highlighting the diagnostic potential of breath analysis for disease diagnosis. Several considerations that need to be taken into account in breath analysis are documented here, including the growing need for metabolomics to deal with breath profiles.
Collapse
Affiliation(s)
- Célia Lourenço
- Department of Life, Health & Chemical Sciences, Chemistry and Analytical Sciences, The Open University, Walton Hall, Milton Keynes, MK7 6AA, UK.
| | - Claire Turner
- Department of Life, Health & Chemical Sciences, Chemistry and Analytical Sciences, The Open University, Walton Hall, Milton Keynes, MK7 6AA, UK.
| |
Collapse
|
53
|
Amann A, Costello BDL, Miekisch W, Schubert J, Buszewski B, Pleil J, Ratcliffe N, Risby T. The human volatilome: volatile organic compounds (VOCs) in exhaled breath, skin emanations, urine, feces and saliva. J Breath Res 2014; 8:034001. [PMID: 24946087 DOI: 10.1088/1752-7155/8/3/034001] [Citation(s) in RCA: 361] [Impact Index Per Article: 36.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Breath analysis is a young field of research with its roots in antiquity. Antoine Lavoisier discovered carbon dioxide in exhaled breath during the period 1777-1783, Wilhelm (Vilém) Petters discovered acetone in breath in 1857 and Johannes Müller reported the first quantitative measurements of acetone in 1898. A recent review reported 1765 volatile compounds appearing in exhaled breath, skin emanations, urine, saliva, human breast milk, blood and feces. For a large number of compounds, real-time analysis of exhaled breath or skin emanations has been performed, e.g., during exertion of effort on a stationary bicycle or during sleep. Volatile compounds in exhaled breath, which record historical exposure, are called the 'exposome'. Changes in biogenic volatile organic compound concentrations can be used to mirror metabolic or (patho)physiological processes in the whole body or blood concentrations of drugs (e.g. propofol) in clinical settings-even during artificial ventilation or during surgery. Also compounds released by bacterial strains like Pseudomonas aeruginosa or Streptococcus pneumonia could be very interesting. Methyl methacrylate (CAS 80-62-6), for example, was observed in the headspace of Streptococcus pneumonia in concentrations up to 1420 ppb. Fecal volatiles have been implicated in differentiating certain infectious bowel diseases such as Clostridium difficile, Campylobacter, Salmonella and Cholera. They have also been used to differentiate other non-infectious conditions such as irritable bowel syndrome and inflammatory bowel disease. In addition, alterations in urine volatiles have been used to detect urinary tract infections, bladder, prostate and other cancers. Peroxidation of lipids and other biomolecules by reactive oxygen species produce volatile compounds like ethane and 1-pentane. Noninvasive detection and therapeutic monitoring of oxidative stress would be highly desirable in autoimmunological, neurological, inflammatory diseases and cancer, but also during surgery and in intensive care units. The investigation of cell cultures opens up new possibilities for elucidation of the biochemical background of volatile compounds. In future studies, combined investigations of a particular compound with regard to human matrices such as breath, urine, saliva and cell culture investigations will lead to novel scientific progress in the field.
Collapse
Affiliation(s)
- Anton Amann
- Univ-Clinic for Anesthesia and Intensive Care, Innsbruck Medical University, Anichstr, 35, A-6020 Innsbruck, Austria. Breath Research Institute of the University of Innsbruck, Rathausplatz 4, A-6850 Dornbirn, Austria
| | | | | | | | | | | | | | | |
Collapse
|
54
|
Biesterbos JWH, Beckmann G, Anzion RBM, Ragas AMJ, Russel FGM, Scheepers PTJ. Sensitive Method for Quantification of Octamethylcyclotetrasiloxane (D4) and Decamethylcyclopentasiloxane (D5) in End-Exhaled Air by Thermal Desorption Gas Chromatography Mass Spectrometry. Anal Chem 2014; 86:5794-9. [DOI: 10.1021/ac5004695] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Affiliation(s)
| | | | | | - Ad M. J. Ragas
- Department
of Environmental Science, Institute for Wetland and Water Research, Radboud University Nijmegen, P.O. Box 9010, 6500 GL Nijmegen, The Netherlands
| | | | | |
Collapse
|
55
|
Mochalski P, Unterkofler K, Španěl P, Smith D, Amann A. Product ion distributions for the reactions of NO + with some physiologically significant aldehydes obtained using a SRI-TOF-MS instrument. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 2014; 363:23-31. [PMID: 25844049 PMCID: PMC4375723 DOI: 10.1016/j.ijms.2014.02.016] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2014] [Accepted: 02/23/2014] [Indexed: 05/07/2023]
Abstract
Product ion distributions for the reactions of NO+ with 22 aldehydes involved in human physiology have been determined under the prevailing conditions of a selective reagent ionization time of flight mass spectrometry (SRI-TOF-MS) at an E/N in the flow/drift tube reactor of 130 Td. The chosen aldehydes were fourteen alkanals (the C2-C11 n-alkanals, 2-methyl propanal, 2-methyl butanal, 3-methyl butanal, and 2-ethyl hexanal), six alkenals (2-propenal, 2-methyl 2-propenal, 2-butenal, 3-methyl 2-butenal, 2-methyl 2-butenal, and 2-undecenal), benzaldehyde, and furfural. The product ion fragmentations patterns were determined for both dry air and humid air (3.5% absolute humidity) used as the matrix buffer/carrier gas in the drift tube of the SRI-TOF-MS instrument. Hydride ion transfer was seen to be a common ionization mechanism in all these aldehydes, thus generating (M-H)+ ions. Small fractions of the adduct ion, NO+M, were also seen for some of the unsaturated alkenals, in particular 2-undecenal, and heterocyclic furfural for which the major reactive channel was non-dissociative charge transfer generating the M+ parent ion. Almost all of the reactions resulted in partial fragmentation of the aldehyde molecules generating hydrocarbon ions; specifically, the alkanal reactions resulted in multiple product ions, whereas, the alkenals reactions produced only two or three product ions, dissociation of the nascent excited product ion occurring preferentially at the 2-position. The findings of this study are of particular importance for data interpretation in studies of aldehydes reactions employing SRI-TOF-MS in the NO+ mode.
Collapse
Affiliation(s)
- Paweł Mochalski
- Breath Research Institute of the University of Innsbruck, Rathausplatz 4, A-6850 Dornbirn, Austria
- Corresponding author. Tel.: +43 512 503 24636; fax: +43 512 504 6724636.
| | - Karl Unterkofler
- Breath Research Institute of the University of Innsbruck, Rathausplatz 4, A-6850 Dornbirn, Austria
- Vorarlberg University of Applied Sciences, Hochschulstr. 1, A-6850 Dornbirn, Austria
| | - Patrik Španěl
- J. Heyrovský Institut of Physical Chemistry, Academy of Sciences of the Czech Republic, Dolejškova 3, 18223 Prague 8, Czech Republic
| | - David Smith
- Institute for Science and Technology in Medicine, Medical School, Keele University, Thornburrow Drive, Hartshill, Stoke-on-Trent ST4 7QB, UK
| | - Anton Amann
- Breath Research Institute of the University of Innsbruck, Rathausplatz 4, A-6850 Dornbirn, Austria
- Univ.-Clinic for Anesthesia and Intensive Care, Innsbruck Medical University, Anichstr 35, A-6020 Innsbruck, Austria
- Corresponding author at: Breath Research Institute of the University of Innsbruck, Rathausplatz 4, A-6850 Dornbirn, Austria. Tel.: +43 512 503 24636; fax: +43 512 504 6724636.
| |
Collapse
|
56
|
Mochalski P, Unterkofler K, Hinterhuber H, Amann A. Monitoring of selected skin-borne volatile markers of entrapped humans by selective reagent ionization time of flight mass spectrometry in NO+ mode. Anal Chem 2014; 86:3915-23. [PMID: 24611620 PMCID: PMC4004195 DOI: 10.1021/ac404242q] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Selective reagent ionization time-of-flight mass spectrometry with NO(+) as the reagent ion (SRI-TOF-MS (NO(+))) was applied for near real-time monitoring of selected skin-borne constituents which are potential markers of human presence. The experimental protocol involved a group of 10 healthy volunteers enclosed in a body plethysmography chamber mimicking the entrapment environment. A total of 12 preselected omnipresent in human scent volatiles were quantitatively monitored. Among them there were six aldehydes (n-propanal, n-hexanal, n-heptanal, n-octanal, n-nonanal, and 2 methyl 2-propenal), four ketones (acetone, 2-butanone, 3-buten-2-one, and 6-methyl-5-hepten-2-one), one hydrocarbon (2-methyl 2-pentene), and one terpene (DL-limonene). The observed median emission rates ranged from 0.28 to 44.8 nmol × person(-1) × min(-1) (16-1530 fmol × cm(-2) × min(-1)). Within the compounds under study, ketones in general and acetone in particular exhibited the highest abundances. The findings of this study provide invaluable information about formation and evolution of a human-specific chemical fingerprint, which could be used for the early location of entrapped victims during urban search and rescue operations (USaR).
Collapse
Affiliation(s)
- Paweł Mochalski
- Breath Research Institute, University of Innsbruck , Rathausplatz 4, A-6850 Dornbirn, Austria
| | | | | | | |
Collapse
|
57
|
Smith D, Španěl P, Herbig J, Beauchamp J. Mass spectrometry for real-time quantitative breath analysis. J Breath Res 2014; 8:027101. [PMID: 24682047 DOI: 10.1088/1752-7155/8/2/027101] [Citation(s) in RCA: 117] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
58
|
Amann A, Mochalski P, Ruzsanyi V, Broza YY, Haick H. Assessment of the exhalation kinetics of volatile cancer biomarkers based on their physicochemical properties. J Breath Res 2014; 8:016003. [PMID: 24566039 DOI: 10.1088/1752-7155/8/1/016003] [Citation(s) in RCA: 73] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
The current review provides an assessment of the exhalation kinetics of volatile organic compounds (VOCs) that have been linked with cancer. Towards this end, we evaluate various physicochemical properties, such as 'breath:air' and 'blood:fat' partition coefficients, of 112 VOCs that have been suggested over the past decade as potential markers of cancer. With these data, we show that the cancer VOC concentrations in the blood and in the fat span over 12 and 8 orders of magnitude, respectively, in order to provide a specific counterpart concentration in the exhaled breath (e.g., 1 ppb). This finding suggests that these 112 different compounds have different storage compartments in the body and that their exhalation kinetics depends on one or a combination of the following factors: (i) the VOC concentrations in different parts of the body; (ii) the VOC synthesis and metabolism rates; (iii) the partition coefficients between tissue(s), blood and air; and (iv) the VOCs' diffusion constants. Based on this analysis, we discuss how this knowledge allows modeling and simulating the behavior of a specific VOC under different sampling protocols (with and without exertion of effort). We end this review by a brief discussion on the potential role of these scenarios in screening and therapeutic monitoring of cancer.
Collapse
Affiliation(s)
- Anton Amann
- Breath Research Institute, Leopold-Franzens University of Innsbruck, 6850 Dornbirn, Austria. Department of Anesthesiology and Critical Care Medicine, Innsbruck Medical University, 6020 Innsbruck, Austria
| | | | | | | | | |
Collapse
|
59
|
Eckel SP, Baumbach J, Hauschild AC. On the importance of statistics in breath analysis--hope or curse? J Breath Res 2014; 8:012001. [PMID: 24565974 DOI: 10.1088/1752-7155/8/1/012001] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Sandrah P Eckel
- Division of Biostatistics, Department of Preventive Medicine, University of Southern California, Los Angeles, CA, USA
| | | | | |
Collapse
|
60
|
Fu XA, Li M, Knipp RJ, Nantz MH, Bousamra M. Noninvasive detection of lung cancer using exhaled breath. Cancer Med 2014; 3:174-81. [PMID: 24402867 PMCID: PMC3930402 DOI: 10.1002/cam4.162] [Citation(s) in RCA: 92] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2013] [Revised: 09/27/2013] [Accepted: 10/11/2013] [Indexed: 12/11/2022] Open
Abstract
Early detection of lung cancer is a key factor for increasing the survival rates of lung cancer patients. The analysis of exhaled breath is promising as a noninvasive diagnostic tool for diagnosis of lung cancer. We demonstrate the quantitative analysis of carbonyl volatile organic compounds (VOCs) and identification of lung cancer VOC markers in exhaled breath using unique silicon microreactor technology. The microreactor consists of thousands of micropillars coated with an ammonium aminooxy salt for capture of carbonyl VOCs in exhaled breath by means of oximation reactions. Captured aminooxy-VOC adducts are analyzed by nanoelectrospray Fourier transform-ion cyclotron resonance (FT-ICR) mass spectrometry (MS). The concentrations of 2-butanone, 2-hydroxyacetaldehyde, 3-hydroxy-2-butanone, and 4-hydroxyhexenal (4-HHE) in the exhaled breath of lung cancer patients (n = 97) were significantly higher than in the exhaled breath of healthy smoker and nonsmoker controls (n = 88) and patients with benign pulmonary nodules (n = 32). The concentration of 2-butanone in exhaled breath of patients (n = 51) with stages II though IV non-small cell lung cancer (NSCLC) was significantly higher than in exhaled breath of patients with stage I (n = 34). The carbonyl VOC profile in exhaled breath determined using this new silicon microreactor technology provides for the noninvasive detection of lung cancer.
Collapse
Affiliation(s)
- Xiao-An Fu
- Department of Chemical Engineering, University of LouisvilleLouisville, Kentucky, 40208
| | - Mingxiao Li
- Department of Chemical Engineering, University of LouisvilleLouisville, Kentucky, 40208
| | - Ralph J Knipp
- Department of Chemistry, University of LouisvilleLouisville, Kentucky, 40208
| | - Michael H Nantz
- Department of Chemistry, University of LouisvilleLouisville, Kentucky, 40208
| | - Michael Bousamra
- Department of Surgery, University of LouisvilleLouisville, Kentucky, 40208
- James Graham Brown Cancer Center, University of LouisvilleLouisville, Kentucky, 40208
| |
Collapse
|
61
|
Haick H, Broza YY, Mochalski P, Ruzsanyi V, Amann A. Assessment, origin, and implementation of breath volatile cancer markers. Chem Soc Rev 2013; 43:1423-49. [PMID: 24305596 DOI: 10.1039/c3cs60329f] [Citation(s) in RCA: 351] [Impact Index Per Article: 31.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
A new non-invasive and potentially inexpensive frontier in the diagnosis of cancer relies on the detection of volatile organic compounds (VOCs) in exhaled breath samples. Breath can be sampled and analyzed in real-time, leading to fascinating and cost-effective clinical diagnostic procedures. Nevertheless, breath analysis is a very young field of research and faces challenges, mainly because the biochemical mechanisms behind the cancer-related VOCs are largely unknown. In this review, we present a list of 115 validated cancer-related VOCs published in the literature during the past decade, and classify them with respect to their "fat-to-blood" and "blood-to-air" partition coefficients. These partition coefficients provide an estimation of the relative concentrations of VOCs in alveolar breath, in blood and in the fat compartments of the human body. Additionally, we try to clarify controversial issues concerning possible experimental malpractice in the field, and propose ways to translate the basic science results as well as the mechanistic understanding to tools (sensors) that could serve as point-of-care diagnostics of cancer. We end this review with a conclusion and a future perspective.
Collapse
Affiliation(s)
- Hossam Haick
- The Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion - Israel Institute of Technology, Haifa 3200003, Israel.
| | | | | | | | | |
Collapse
|
62
|
Abstract
Breath analysis is an attractive non-invasive method for diagnosis and therapeutic monitoring. It uses endogenously produced compounds and metabolites of isotopically labeled precursors. In order to make such tests clinically useful, it is important to have relatively small portable instruments detecting volatile compounds within short time. A particularly promising analytical technique is ion mobility spectrometry (IMS) coupled to a multi capillary column (MCC). This paper focuses on demonstrating the suitability of breath analysis for pharmacokinetic applications using MCC-IMS with respect to practicability and reproducibility testing the model substrate eucalyptol. Validation of the MCC-IMS measurements were performed using proton transfer reaction mass spectrometry (PTR-MS) and resulted in an excellent correspondence of the time-dependent concentrations presented by the two different analytical techniques. Moreover, the good accordance in variance of kinetic parameters with repeated measures, and the determined inter-subject differences indicate the eligibility of the analysis method.
Collapse
Affiliation(s)
- V Ruzsanyi
- Breath Research Institute of the Austrian Academy of Sciences, Rathausplatz 4, A-6850 Dornbirn, Austria. Department of Anesthesia and Intensive Care, Innsbruck Medical University, Anichstr. 35, A-6020 Innsbruck, Austria
| |
Collapse
|
63
|
Mochalski P, King J, Unterkofler K, Amann A. Stability of selected volatile breath constituents in Tedlar, Kynar and Flexfilm sampling bags. Analyst 2013; 138:1405-18. [PMID: 23323261 DOI: 10.1039/c2an36193k] [Citation(s) in RCA: 76] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
The stability of 41 selected breath constituents in three types of polymer sampling bags, Tedlar, Kynar, and Flexfilm, was investigated using solid phase microextraction and gas chromatography mass spectrometry. The tested molecular species belong to different chemical classes (hydrocarbons, ketones, aldehydes, aromatics, sulphurs, esters, terpenes, etc.) and exhibit close-to-breath low ppb levels (3-12 ppb) with the exception of isoprene, acetone and acetonitrile (106 ppb, 760 ppb, 42 ppb respectively). Stability tests comprised the background emission of contaminants, recovery from dry samples, recovery from humid samples (RH 80% at 37 °C), influence of the bag's filling degree, and reusability. Findings yield evidence of the superiority of Tedlar bags over remaining polymers in terms of background emission, species stability (up to 7 days for dry samples), and reusability. Recoveries of species under study suffered from the presence of high amounts of water (losses up to 10%). However, only heavier volatiles, with molecular masses higher than 90, exhibited more pronounced losses (20-40%). The sample size (the degree of bag filling) was found to be one of the most important factors affecting the sample integrity. To sum up, it is recommended to store breath samples in pre-conditioned Tedlar bags up to 6 hours at the maximum possible filling volume. Among the remaining films, Kynar can be considered as an alternative to Tedlar; however, higher losses of compounds should be expected even within the first hours of storage. Due to the high background emission Flexfilm is not suitable for sampling and storage of samples for analyses aiming at volatiles at a low ppb level.
Collapse
Affiliation(s)
- Paweł Mochalski
- Breath Research Institute, Austrian Academy of Sciences, Rathausplatz 4, A-6850 Dornbirn, Austria.
| | | | | | | |
Collapse
|
64
|
Trefz P, Schmidt M, Oertel P, Obermeier J, Brock B, Kamysek S, Dunkl J, Zimmermann R, Schubert JK, Miekisch W. Continuous Real Time Breath Gas Monitoring in the Clinical Environment by Proton-Transfer-Reaction-Time-of-Flight-Mass Spectrometry. Anal Chem 2013; 85:10321-9. [DOI: 10.1021/ac402298v] [Citation(s) in RCA: 100] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Affiliation(s)
- Phillip Trefz
- Department of Anaesthesia
and Intensive Care, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany
| | - Markus Schmidt
- Department of Anaesthesia
and Intensive Care, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany
| | - Peter Oertel
- Department of Anaesthesia
and Intensive Care, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany
| | - Juliane Obermeier
- Department of Anaesthesia
and Intensive Care, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany
| | - Beate Brock
- Department of Anaesthesia
and Intensive Care, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany
| | - Svend Kamysek
- Department of Anaesthesia
and Intensive Care, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany
| | - Jürgen Dunkl
- Ionicon Analytik GmbH, Eduard-Bodem-Gasse 3, A-6020 Innsbruck, Austria
| | - Ralf Zimmermann
- Joint Mass Spectrometry
Centre, Chair of Analytical Chemistry, University of Rostock, Dr. Lorenz Weg
1, 18059 Rostock, Germany and Joint Mass Spectrometry Centre, Cooperation Group “Comprehensive
Molecular Analytics”, Helmholtz Zentrum München, D-85764 Neuherberg, Germany
| | - Jochen K. Schubert
- Department of Anaesthesia
and Intensive Care, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany
| | - Wolfram Miekisch
- Department of Anaesthesia
and Intensive Care, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany
| |
Collapse
|
65
|
Righettoni M, Schmid A, Amann A, Pratsinis SE. Correlations between blood glucose and breath components from portable gas sensors and PTR-TOF-MS. J Breath Res 2013; 7:037110. [DOI: 10.1088/1752-7155/7/3/037110] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
66
|
Wang Z, Wang C. Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements. J Breath Res 2013; 7:037109. [DOI: 10.1088/1752-7155/7/3/037109] [Citation(s) in RCA: 164] [Impact Index Per Article: 14.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
67
|
Mochalski P, Rudnicka J, Agapiou A, Statheropoulos M, Amann A, Buszewski B. Near real-time VOCs analysis using an aspiration ion mobility spectrometer. J Breath Res 2013; 7:026002. [DOI: 10.1088/1752-7155/7/2/026002] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
68
|
Schmidt FM, Vaittinen O, Metsälä M, Lehto M, Forsblom C, Groop PH, Halonen L. Ammonia in breath and emitted from skin. J Breath Res 2013; 7:017109. [PMID: 23445955 DOI: 10.1088/1752-7155/7/1/017109] [Citation(s) in RCA: 70] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Ammonia concentrations in exhaled breath (eNH3) and skin gas of 20 healthy subjects were measured on-line with a commercial cavity ring-down spectrometer and compared to saliva pH and plasma ammonium ion (NH(+)4), urea and creatinine concentrations. Special attention was given to mouth, nose and skin sampling procedures and the accurate quantification of ammonia in humid gas samples. The obtained median concentrations were 688 parts per billion by volume (ppbv) for mouth-eNH3, 34 ppbv for nose-eNH3, and 21 ppbv for both mouth- and nose-eNH3 after an acidic mouth wash (MW). The median ammonia emission rate from the lower forearm was 0.3 ng cm(-2) min(-1). Statistically significant (p < 0.05) correlations between the breath, skin and plasma ammonia/ammonium concentrations were not found. However, mouth-eNH3 strongly (p < 0.001) correlated with saliva pH. This dependence was also observed in detailed measurements of the diurnal variation and the response of eNH3 to the acidic MW. It is concluded that eNH3 as such does not reflect plasma but saliva and airway mucus NH(+)4 concentrations and is affected by saliva and airway mucus pH. After normalization with saliva pH using the Henderson-Hasselbalch equation, mouth-eNH3 correlated with plasma NH(+)4, which points to saliva and plasma NH(+)4 being linked via hydrolysis of salivary urea.
Collapse
Affiliation(s)
- F M Schmidt
- Laboratory of Physical Chemistry, Department of Chemistry, University of Helsinki, Finland.
| | | | | | | | | | | | | |
Collapse
|
69
|
Abstract
Highly blood soluble gases exchange with the bronchial circulation in the airways. On inhalation, air absorbs highly soluble gases from the airway mucosa and equilibrates with the blood before reaching the alveoli. Highly soluble gas partial pressure is identical throughout all alveoli. At the end of exhalation the partial pressure of a highly soluble gas decreases from the alveolar level in the terminal bronchioles to the end-exhaled partial pressure at the mouth. A mathematical model simulated the airway exchange of four gases (methyl isobutyl ketone, acetone, ethanol, and propylene glycol monomethyl ether) that have high water and blood solubility. The impact of solubility on the relative distribution of airway exchange was studied. We conclude that an increase in water solubility shifts the distribution of gas exchange toward the mouth. Of the four gases studied, ethanol had the greatest decrease in partial pressure from the alveolus to the mouth at end exhalation. Single exhalation breath tests are inappropriate for estimating alveolar levels of highly soluble gases, particularly for ethanol.
Collapse
Affiliation(s)
- Michael P Hlastala
- Division of Pulmonary and Critical Care Medicine, University of Washington, Seattle, Washington 98195, USA.
| | | | | |
Collapse
|
70
|
Halbritter S, Fedrigo M, Höllriegl V, Szymczak W, Maier JM, Ziegler AG, Hummel M. Human breath gas analysis in the screening of gestational diabetes mellitus. Diabetes Technol Ther 2012; 14:917-25. [PMID: 22775148 PMCID: PMC3459034 DOI: 10.1089/dia.2012.0076] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
BACKGROUND We present a pilot study on the feasibility of the application and advantages of online, noninvasive breath gas analysis (BGA) by proton transfer reaction quadrupole mass spectrometry for the screening of gestational diabetes mellitus (GDM) in 52 pregnant women by means of an oral glucose tolerance test (OGTT). SUBJECTS AND METHODS We collected and identified samples of end-tidal breath gas from patients during OGTT. Time evolution parameters of challenge-responsive volatile organic compounds (VOCs) in human breath gas were estimated. Multivariate analysis of variance and permutation analysis were used to assess feasibility of BGA as a diagnostic tool for GDM. RESULTS Standard OGTT diagnosis identified pregnant women as having GDM (n = 8), impaired glucose tolerance (n = 12), and normal glucose tolerance (n = 32); a part of this latter group was further subdivided into a "marginal" group (n = 9) because of a marginal high 1-h or 2-h OGTT value. We observed that OGTT diagnosis (four metabolic groups) could be mapped into breath gas data. The time evolution of oxidation products of glucose and lipids, acetone metabolites, and thiols in breath gas after a glucose challenge was correlated with GDM diagnosis (P = 0.035). Furthermore, basal (fasting) values of dimethyl sulfide and values of methanol in breath gas were inversely correlated with phenotype characteristics such as homeostasis model assessment of insulin resistance index (R = -0.538; P = 0.0002, P(corrected) = 0.0034) and pregestational body mass index (R = -0.433; P = 0.0013, P(corrected) = 0.022). CONCLUSIONS Noninvasive BGA in challenge response studies was successfully applied to GDM diagnosis and offered an insight into metabolic pathways involved. We propose a new approach to the identification of diagnosis thresholds for GDM screening.
Collapse
Affiliation(s)
- Susanne Halbritter
- Research Unit Medical Radiation Physics and Diagnostics, Helmholtz Center Munich, Neuherberg, Germany
| | - Mattia Fedrigo
- Research Unit Medical Radiation Physics and Diagnostics, Helmholtz Center Munich, Neuherberg, Germany
| | - Vera Höllriegl
- Research Unit Medical Radiation Physics and Diagnostics, Helmholtz Center Munich, Neuherberg, Germany
| | - Wilfried Szymczak
- Research Unit Medical Radiation Physics and Diagnostics, Helmholtz Center Munich, Neuherberg, Germany
| | - Joerg M. Maier
- Institute of Diabetes Research, Helmholtz Center Munich, Munich, Germany
- Diabetes Research Group, Hospital Rechts der Isar, Technical University of Munich, Munich, Germany
- Diabetes Research Group e.V., Munich-Neuherberg, Germany
| | - Anette-Gabriele Ziegler
- Institute of Diabetes Research, Helmholtz Center Munich, Munich, Germany
- Diabetes Research Group, Hospital Rechts der Isar, Technical University of Munich, Munich, Germany
- Diabetes Research Group e.V., Munich-Neuherberg, Germany
| | - Michael Hummel
- Diabetes Research Group e.V., Munich-Neuherberg, Germany
| |
Collapse
|
71
|
Hakim M, Broza YY, Barash O, Peled N, Phillips M, Amann A, Haick H. Volatile organic compounds of lung cancer and possible biochemical pathways. Chem Rev 2012; 112:5949-66. [PMID: 22991938 DOI: 10.1021/cr300174a] [Citation(s) in RCA: 485] [Impact Index Per Article: 40.4] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Meggie Hakim
- The Department of Chemical Engineering, Technion-Israel Institute of Technology, Haifa, Israel
| | | | | | | | | | | | | |
Collapse
|
72
|
Luque de Castro M, Fernández-Peralbo M. Analytical methods based on exhaled breath for early detection of lung cancer. Trends Analyt Chem 2012. [DOI: 10.1016/j.trac.2012.03.018] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
73
|
Buszewski B, Rudnicka J, Ligor T, Walczak M, Jezierski T, Amann A. Analytical and unconventional methods of cancer detection using odor. Trends Analyt Chem 2012. [DOI: 10.1016/j.trac.2012.03.019] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
74
|
Prabhakar A, Iglesias RA, Shan X, Xian X, Zhang L, Tsow F, Forzani ES, Tao N. Online sample conditioning for portable breath analyzers. Anal Chem 2012; 84:7172-8. [PMID: 22812638 DOI: 10.1021/ac301542j] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Various innovative chemical sensors have been developed in recent years to sense dangerous substances in air and trace biomarkers in breath. However, in order to solve real world problems, the sensors must be equipped with efficient sample conditioning that can, e.g., control the humidity, which is discussed much less in the literature. To meet the demand, a miniaturized mouthpiece was developed for personal breath analyzers. A key function of the mouthpiece is to condition the humidity in real breath samples without changing the analyte concentrations and introducing substantial backpressure, which is achieved with optimized packing of desiccant particles. Numerical simulations were carried out to determine the performance of the mouthpiece in terms of various controllable parameters, such as the size, density, and geometry of the packing. Mouthpieces with different configurations were built and tested, and the experimental data validated the simulation findings. A mouthpiece with optimized performance reducing relative humidity from 95% (27,000 ppmV) to 29% (8000 ppmV) whereas retaining 92% nitric oxide (50 ppbV to 46 ppbV) was built and integrated into a hand-held exhaled nitric oxide sensor, and the performance of exhaled nitric oxide measurement was in good agreement with the gold standard chemiluminescence technique. Acetone, carbon dioxide, oxygen, and ammonia samples were also measured after passing through the desiccant mouthpiece using commercial sensors to examine wide applicability of this breath conditioning approach.
Collapse
Affiliation(s)
- Amlendu Prabhakar
- Center for Bioelectronics & Biosensors, Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
| | | | | | | | | | | | | | | |
Collapse
|
75
|
Minh TDC, Blake DR, Galassetti PR. The clinical potential of exhaled breath analysis for diabetes mellitus. Diabetes Res Clin Pract 2012; 97:195-205. [PMID: 22410396 PMCID: PMC3384765 DOI: 10.1016/j.diabres.2012.02.006] [Citation(s) in RCA: 85] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/06/2011] [Revised: 02/02/2012] [Accepted: 02/12/2012] [Indexed: 01/15/2023]
Abstract
Various compounds in present human breath have long been loosely associated with pathological states (including acetone smell in uncontrolled diabetes). Only recently, however, the precise measurement of exhaled volatile organic compounds (VOCs) and aerosolized particles was made possible at extremely low concentrations by advances in several analytical methodologies, described in detail in the international literature and each suitable for specific subsets of exhaled compounds. Exhaled gases may be generated endogenously (in the pulmonary tract, blood, or peripheral tissues), as metabolic by-products of human cells or colonizing micro-organisms, or may be inhaled as atmospheric pollutants; growing evidence indicates that several of these molecules have distinct cell-to-cell signaling functions. Independent of origin and physiological role, exhaled VOCs are attractive candidates as biomarkers of cellular activity/metabolism, and could be incorporated in future non-invasive clinical testing devices. Indeed, several recent studies reported altered exhaled gas profiles in dysmetabolic conditions and relatively accurate predictions of glucose concentrations, at least in controlled experimental conditions, for healthy and diabetic subjects over a broad range of glycemic values. Optimization of this methodology and validation in large-scale trials under a wider range of conditions is needed to determine its true potential to transition into practical clinical use.
Collapse
Affiliation(s)
- Timothy Do Chau Minh
- Department of Pharmacology, University of California, Irvine, Irvine, CA 92697-1385, United States.
| | | | | |
Collapse
|
76
|
Tan BK, Davies SJ, Spaněl P, Smith D. Injection of deuterated water into the pulmonary/alveolar circulation; measurement of HDO in exhaled breath and implications to breath analysis. J Breath Res 2012; 6:036005. [PMID: 22824740 DOI: 10.1088/1752-7155/6/3/036005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The results of experiments are described in which a known quantity of sterile deuterated water is injected directly into the pulmonary circulation via the right internal jugular vein of several haemodialysis patients and the deuterium to hydrogen ratio, D/H, in the exhaled lung water was measured using the flowing afterglow mass spectrometry technique. The breath D/H abundance was measured in sequential breath exhalations before and after the injection, providing data that are sufficiently detailed to follow the production and loss rate of D/H in the exhaled breath. Thus, in principle, considering isotope dilution the volume of water in the lungs and pulmonary circulation can be derived. However, it is seen that the maximum abundance that the breath D/H reached was much lower than anticipated by considering the likely volume of blood/water in the pulmonary circulation and so it is deduced that either 'leakage' of the injected deuterated water rapidly occurs from the pulmonary to the systemic circulation and/or isotope exchange of deuterium with hydrogen along the bronchial tree efficiently occurs, thus reducing the D/H in the exhaled breath. This latter phenomenon has important implications to breath analysis in which it is often assumed that so-called alveolar breath concentrations of metabolites reflect blood/systemic levels. Detailed consideration of the breath D/H abundances when the deuterium is equilibrated amongst the total body water, TBW, of the patients, which occurs about 40 min after injection of the deuterated water, allows the TBW of the patients to be estimated.
Collapse
Affiliation(s)
- Boon K Tan
- Institute for Science and Technology in Medicine, Keele University, Thornburrow Drive, Hartshill, Stoke on Trent ST4 7QB, UK
| | | | | | | |
Collapse
|
77
|
Breath acetone monitoring by portable Si:WO3 gas sensors. Anal Chim Acta 2012; 738:69-75. [PMID: 22790702 DOI: 10.1016/j.aca.2012.06.002] [Citation(s) in RCA: 119] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Revised: 05/28/2012] [Accepted: 06/03/2012] [Indexed: 11/22/2022]
Abstract
Breath analysis has the potential for early stage detection and monitoring of illnesses to drastically reduce the corresponding medical diagnostic costs and improve the quality of life of patients suffering from chronic illnesses. In particular, the detection of acetone in the human breath is promising for non-invasive diagnosis and painless monitoring of diabetes (no finger pricking). Here, a portable acetone sensor consisting of flame-deposited and in situ annealed, Si-doped epsilon-WO(3) nanostructured films was developed. The chamber volume was miniaturized while reaction-limited and transport-limited gas flow rates were identified and sensing temperatures were optimized resulting in a low detection limit of acetone (∼20ppb) with short response (10-15s) and recovery times (35-70s). Furthermore, the sensor signal (response) was robust against variations of the exhaled breath flow rate facilitating application of these sensors at realistic relative humidities (80-90%) as in the human breath. The acetone content in the breath of test persons was monitored continuously and compared to that of state-of-the-art proton transfer reaction mass spectrometry (PTR-MS). Such portable devices can accurately track breath acetone concentration to become an alternative to more elaborate breath analysis techniques.
Collapse
|
78
|
King J, Mochalski P, Unterkofler K, Teschl G, Klieber M, Stein M, Amann A, Baumann M. Breath isoprene: muscle dystrophy patients support the concept of a pool of isoprene in the periphery of the human body. Biochem Biophys Res Commun 2012; 423:526-30. [PMID: 22683640 DOI: 10.1016/j.bbrc.2012.05.159] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2012] [Accepted: 05/30/2012] [Indexed: 01/18/2023]
Abstract
Breath isoprene accounts for most of the hydrocarbon removal via exhalation and is thought to serve as a non-invasive indicator for assaying several metabolic effects in the human body. The primary objective of this paper is to introduce a novel working hypothesis with respect to the endogenous source of this compound in humans: the idea that muscle tissue acts as an extrahepatic production site of substantial amounts of isoprene. This new perspective has its roots in quantitative modeling studies of breath isoprene dynamics under exercise conditions and is further investigated here by presenting pilot data from a small cohort of late stage Duchenne muscle dystrophy patients (median age 21, 4 male, 1 female). For these prototypic test subjects isoprene concentrations in end-tidal breath and peripheral venous blood range between 0.09-0.47 and 0.11-0.72 nmol/l, respectively, amounting to a reduction by a factor of 8 and more as compared to established nominal levels in normal healthy adults. While it remains unclear whether isoprene can be ascribed a direct physiological mechanism of action, some indications are given as to why isoprene production might have evolved in muscle.
Collapse
Affiliation(s)
- J King
- Breath Research Institute, Austrian Academy of Sciences, Rathausplatz 4, A-6850 Dornbirn, Austria
| | | | | | | | | | | | | | | |
Collapse
|
79
|
King J, Kupferthaler A, Frauscher B, Hackner H, Unterkofler K, Teschl G, Hinterhuber H, Amann A, Högl B. Measurement of endogenous acetone and isoprene in exhaled breath during sleep. Physiol Meas 2012; 33:413-28. [PMID: 22370046 DOI: 10.1088/0967-3334/33/3/413] [Citation(s) in RCA: 106] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
This explorative study aims at characterizing the breath behavior of two prototypic volatile organic compounds, acetone and isoprene, during normal human sleep and to possibly relate changes in the respective concentration time courses to the underlying sleep architecture. For this purpose, six normal healthy volunteers (two females, four males, age 20-29 years) were monitored over two consecutive nights (the first one being an adaption night) by combining real-time proton-transfer-reaction mass spectrometry measurements from end-tidal exhalation segments with laboratory-based polysomnographic data. Breath acetone concentrations increased overnight in all measurements, with an average relative change by a factor of up to 4 (median 2.5). Nighttime concentration maxima were usually recorded 2-3 h before lights on. For breath isoprene, a nocturnal increase in baseline concentrations of about 74% was observed, with individual changes ranging from 36-110%. Isoprene profiles exhibited pronounced concentration peaks, which were highly specific for leg movements as scored by tibial electromyography. Furthermore, relative to a linear trend, baseline isoprene concentrations decreased during the transition from the NREM to the REM phase of a complete sleep cycle.
Collapse
Affiliation(s)
- Julian King
- Breath Research Institute, Austrian Academy of Sciences, Rathausplatz 4, A-6850 Dornbirn, Austria
| | | | | | | | | | | | | | | | | |
Collapse
|
80
|
King J, Unterkofler K, Teschl G, Teschl S, Mochalski P, Koç H, Hinterhuber H, Amann A. A modeling-based evaluation of isothermal rebreathing for breath gas analyses of highly soluble volatile organic compounds. J Breath Res 2012; 6:016005. [DOI: 10.1088/1752-7155/6/1/016005] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
81
|
Mochalski P, King J, Kupferthaler A, Unterkofler K, Hinterhuber H, Amann A. Measurement of isoprene solubility in water, human blood and plasma by multiple headspace extraction gas chromatography coupled with solid phase microextraction. J Breath Res 2011; 5:046010. [DOI: 10.1088/1752-7155/5/4/046010] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|