51
|
Wong ML, Wong JL, Vapniarsky N, Griffiths LG. In vivo xenogeneic scaffold fate is determined by residual antigenicity and extracellular matrix preservation. Biomaterials 2016; 92:1-12. [PMID: 27031928 DOI: 10.1016/j.biomaterials.2016.03.024] [Citation(s) in RCA: 82] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2015] [Revised: 03/15/2016] [Accepted: 03/16/2016] [Indexed: 01/08/2023]
Abstract
The immunological potential of animal-derived tissues and organs is the critical hurdle to increasing their clinical implementation. Glutaraldehyde-fixation cross-links proteins in xenogeneic tissues (e.g., bovine pericardium) to delay immune rejection, but also compromises the regenerative potential of the resultant biomaterial. Unfixed xenogeneic biomaterials in which xenoantigenicity has been ameliorated and native extracellular matrix (ECM) architecture has been maintained have the potential to overcome limitations of current clinically utilized glutaraldehyde-fixed biomaterials. The objective of this work was to determine how residual antigenicity and ECM architecture preservation modulate recipient immune and regenerative responses towards unfixed bovine pericardium (BP) ECM scaffolds. Disruption of ECM architecture during scaffold generation, with either SDS-decellularization or glutaraldehyde-fixation, stimulated recipient foreign body response and resultant fibrotic encapsulation following leporine subpannicular implantation. Conversely, BP scaffolds subjected to stepwise removal of hydrophilic and lipophilic antigens using amidosulfobetaine-14 (ASB-14) maintained native ECM architecture and thereby avoided fibrotic encapsulation. Removal of hydrophilic and lipophilic antigens significantly decreased local and systemic graft-specific, adaptive immune responses and subsequent calcification of BP scaffolds compared to scaffolds undergoing hydrophile removal only. Critically, removal of antigenic components and preservation of ECM architecture with ASB-14 promoted full-thickness recipient non-immune cellular repopulation of the BP scaffold. Further, unlike clinically utilized fixed BP, ASB-14-treated scaffolds fostered rapid intimal and medial vessel wall regeneration in a porcine carotid patch angioplasty model. This work highlights the importance of residual antigenicity and ECM architecture preservation in modulating recipient immune and regenerative responses towards xenogeneic biomaterial generation.
Collapse
Affiliation(s)
- Maelene L Wong
- Department of Veterinary Medicine and Epidemiology, University of California, Davis, One Shields Ave., Davis, CA 95616, USA; Department of Biomedical Engineering, University of California, Davis, One Shields Ave., Davis, CA 95616, USA
| | - Janelle L Wong
- Department of Veterinary Medicine and Epidemiology, University of California, Davis, One Shields Ave., Davis, CA 95616, USA
| | - Natalia Vapniarsky
- Department of Biomedical Engineering, University of California, Davis, One Shields Ave., Davis, CA 95616, USA
| | - Leigh G Griffiths
- Department of Veterinary Medicine and Epidemiology, University of California, Davis, One Shields Ave., Davis, CA 95616, USA.
| |
Collapse
|
52
|
Kehl D, Weber B, Hoerstrup SP. Bioengineered living cardiac and venous valve replacements: current status and future prospects. Cardiovasc Pathol 2016; 25:300-305. [PMID: 27167776 DOI: 10.1016/j.carpath.2016.03.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Revised: 02/19/2016] [Accepted: 03/08/2016] [Indexed: 12/13/2022] Open
Abstract
Valvular heart disease remains to be a major cause of death worldwide with increasing prevalence, mortality, and morbidity. Current heart valve replacements are associated with several limitations due to their nonviable nature. In this regard, heart valve tissue engineering has shown to represent a promising concept in order to overcome these limitations and replace diseased cardiac valves with living, autologous constructs. These bioengineered valves hold potential for in situ remodeling, growth, and repair throughout the patient's lifetime without the risk of thromboembolic complications and adverse immune responses. For the fabrication of tissue-engineered heart valves, several concepts have been established, the "classical" in vitro tissue engineering approach, the in situ tissue engineering approach, and alternative approaches including three-dimensional printing and electrospinning. Besides first attempts have been conducted in order to produce a tissue-engineered venous valve for the treatment of deep venous valve insufficiency. Here we review basic principals and current scientific status of valvular tissue engineering, including a critical discussion and outlook for the future.
Collapse
Affiliation(s)
- Debora Kehl
- Institute for Regenerative Medicine, University of Zurich Center for Therapy Development/Good Manufacturing Practice, Moussonstrasse 13, CH-8044 Zurich, Switzerland
| | - Benedikt Weber
- Institute for Regenerative Medicine, University of Zurich Center for Therapy Development/Good Manufacturing Practice, Moussonstrasse 13, CH-8044 Zurich, Switzerland
| | - Simon Philipp Hoerstrup
- Institute for Regenerative Medicine, University of Zurich Center for Therapy Development/Good Manufacturing Practice, Moussonstrasse 13, CH-8044 Zurich, Switzerland.
| |
Collapse
|
53
|
Kajbafzadeh AM, Ahmadi Tafti SH, Mokhber-Dezfooli MR, Khorramirouz R, Sabetkish S, Sabetkish N, Rabbani S, Tavana H, Mohseni MJ. Aortic valve conduit implantation in the descending thoracic aorta in a sheep model: The outcomes of pre-seeded scaffold. Int J Surg 2016; 28:97-105. [PMID: 26923632 DOI: 10.1016/j.ijsu.2016.02.061] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2015] [Revised: 01/31/2016] [Accepted: 02/12/2016] [Indexed: 11/18/2022]
Abstract
BACKGROUND We evaluated the outcomes of implanting pre-seeded decellularized aortic valve conduit (AVC) with bone marrow-derived mesenchymal stem cells (MSCs) in a sheep model. METHODS Eight sheep AVCs were obtained under sterile conditions and decellularized by using detergent-based methods. Decellularized AVCs were seeded with autologous bone marrow-derived MSCs in a dynamic bioreactor system. Pre-seeded AVCs were implanted in the descending thoracic aorta in a sheep model. In all sheep, a decellularized pericardial patch was also anastomosed to the proximal part in order to reduce the incidence of rupture. Pathological evaluations, echocardiography, multislice computed tomography (CT), and CT angiography were performed for the evaluation of implanted AVCs. RESULTS The longest survival period was 19 months in pre-seeded animals with complete recellularization at the long-term follow-up. Immunohistochemical staining for desmin, smooth muscle actin, and cytokeratin was significantly positive in the pre-seeded samples and reached near normal ranges. CT angiography revealed no intimal tearing after 18 months of follow-up. CONCLUSION Pre-seeded AVCs with bone marrow-derived MSCs may have satisfactory results in postoperative cell seeding capabilities with promising functional potentiality. This modality may be beneficial and may provide a new era of biological grafts in cardiovascular surgery.
Collapse
Affiliation(s)
- Abdol-Mohammad Kajbafzadeh
- Pediatric Urology Research Center, Section of Tissue Engineering and Stem Cells Therapy, Tehran University of Medical Sciences, Tehran, Islamic Republic of Iran.
| | | | - Mohammad-Reza Mokhber-Dezfooli
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Tehran University of Medical Sciences, Tehran, Islamic Republic of Iran
| | - Reza Khorramirouz
- Pediatric Urology Research Center, Section of Tissue Engineering and Stem Cells Therapy, Tehran University of Medical Sciences, Tehran, Islamic Republic of Iran
| | - Shabnam Sabetkish
- Pediatric Urology Research Center, Section of Tissue Engineering and Stem Cells Therapy, Tehran University of Medical Sciences, Tehran, Islamic Republic of Iran
| | - Nastaran Sabetkish
- Pediatric Urology Research Center, Section of Tissue Engineering and Stem Cells Therapy, Tehran University of Medical Sciences, Tehran, Islamic Republic of Iran
| | - Shahram Rabbani
- Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Islamic Republic of Iran
| | - Hamid Tavana
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Tehran University of Medical Sciences, Tehran, Islamic Republic of Iran
| | - Mohammad Javad Mohseni
- Pediatric Urology Research Center, Section of Tissue Engineering and Stem Cells Therapy, Tehran University of Medical Sciences, Tehran, Islamic Republic of Iran
| |
Collapse
|
54
|
Bioprinting a cardiac valve. Biotechnol Adv 2015; 33:1503-21. [DOI: 10.1016/j.biotechadv.2015.07.006] [Citation(s) in RCA: 97] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2015] [Revised: 06/30/2015] [Accepted: 07/27/2015] [Indexed: 12/13/2022]
|
55
|
Schmack B, Szabó G, Karck M, Weymann A. Tissue-Engineering von Atrioventrikularklappen. ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE 2015. [DOI: 10.1007/s00398-015-0028-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
56
|
Rath S, Salinas M, Villegas AG, Ramaswamy S. Differentiation and Distribution of Marrow Stem Cells in Flex-Flow Environments Demonstrate Support of the Valvular Phenotype. PLoS One 2015; 10:e0141802. [PMID: 26536240 PMCID: PMC4633293 DOI: 10.1371/journal.pone.0141802] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2015] [Accepted: 10/13/2015] [Indexed: 11/18/2022] Open
Abstract
For treatment of critical heart valve diseases, prosthetic valves perform fairly well in most adults; however, for pediatric patients, there is the added requirement that the replacement valve grows with the child, thus extremely limiting current treatment options. Tissue engineered heart valves (TEHV), such as those derived from autologous bone marrow stem cells (BMSCs), have the potential to recapitulate native valve architecture and accommodate somatic growth. However, a fundamental pre-cursor in promoting directed integration with native tissues rather than random, uncontrolled growth requires an understanding of BMSC mechanobiological responses to valve-relevant mechanical environments. Here, we report on the responses of human BMSC-seeded polymer constructs to the valve-relevant stress states of: (i) steady flow alone, (ii) cyclic flexure alone, and (iii) the combination of cyclic flexure and steady flow (flex-flow). BMSCs were seeded onto a PGA: PLLA polymer scaffold and cultured in static culture for 8 days. Subsequently, the aforementioned mechanical conditions, (groups consisting of steady flow alone-850ml/min, cyclic flexure alone-1 Hz, and flex-flow-850ml/min and 1 Hz) were applied for an additional two weeks. We found samples from the flex-flow group exhibited a valve-like distribution of cells that expressed endothelial (preference to the surfaces) and myofibroblast (preference to the intermediate region) phenotypes. We interpret that this was likely due to the presence of both appreciable fluid-induced shear stress magnitudes and oscillatory shear stresses, which were concomitantly imparted onto the samples. These results indicate that flex-flow mechanical environments support directed in vitro differentiation of BMSCs uniquely towards a heart valve phenotype, as evident by cellular distribution and expression of specific gene markers. A priori guidance of BMSC-derived, engineered tissue growth under flex-flow conditions may serve to subsequently promote controlled, engineered to native tissue integration processes in vivo necessary for successful long-term valve remodeling.
Collapse
Affiliation(s)
- Sasmita Rath
- Department of Biomedical Engineering, Florida International University, Miami, FL, 33174, United States of America
| | - Manuel Salinas
- Department of Biomedical Engineering, Florida International University, Miami, FL, 33174, United States of America
| | - Ana G. Villegas
- Department of Biomedical Engineering, Florida International University, Miami, FL, 33174, United States of America
| | - Sharan Ramaswamy
- Department of Biomedical Engineering, Florida International University, Miami, FL, 33174, United States of America
| |
Collapse
|
57
|
Shieh SJ, Cheng TC. Regeneration and repair of human digits and limbs: fact and fiction. ACTA ACUST UNITED AC 2015; 2:149-68. [PMID: 27499873 PMCID: PMC4857729 DOI: 10.1002/reg2.41] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2015] [Revised: 08/08/2015] [Accepted: 08/10/2015] [Indexed: 12/15/2022]
Abstract
A variety of digit and limb repair and reconstruction methods have been used in different clinical settings, but regeneration remains an item on every plastic surgeon's "wish list." Although surgical salvage techniques are continually being improved, unreplantable digits and limbs are still abundant. We comprehensively review the structural and functional salvage methods in clinical practice, from the peeling injuries of small distal fingertips to multisegmented amputated limbs, and the developmental and tissue engineering approaches for regenerating human digits and limbs in the laboratory. Although surgical techniques have forged ahead, there are still situations in which digits and limbs are unreplantable. Advances in the field are delineated, and the regeneration processes of salamander limbs, lizard tails, and mouse digits and each component of tissue engineering approaches for digit- and limb-building are discussed. Although the current technology is promising, there are many challenges in human digit and limb regeneration. We hope this review inspires research on the critical gap between clinical and basic science, and leads to more sophisticated digit and limb loss rescue and regeneration innovations.
Collapse
Affiliation(s)
- Shyh-Jou Shieh
- Division of Plastic and Reconstructive Surgery, Department of Surgery, National Cheng Kung University Hospital, College of Medicine National Cheng Kung University Tainan Taiwan; International Research Center for Wound Repair and Regeneration (iWRR) National Cheng Kung University Tainan Taiwan
| | - Tsun-Chih Cheng
- Division of Plastic and Reconstructive Surgery, Department of Surgery, National Cheng Kung University Hospital, College of Medicine National Cheng Kung University Tainan Taiwan
| |
Collapse
|
58
|
Abstract
Heart disease, including valve pathologies, is the leading cause of death worldwide. Despite the progress made thanks to improving transplantation techniques, a perfect valve substitute has not yet been developed: once a diseased valve is replaced with current technologies, the newly implanted valve still needs to be changed some time in the future. This situation is particularly dramatic in the case of children and young adults, because of the necessity of valve growth during the patient's life. Our review focuses on the current status of heart valve (HV) therapy and the challenges that must be solved in the development of new approaches based on tissue engineering. Scientists and physicians have proposed tissue-engineered heart valves (TEHVs) as the most promising solution for HV replacement, especially given that they can help to avoid thrombosis, structural deterioration and xenoinfections. Lastly, TEHVs might also serve as a model for studying human valve development and pathologies.
Collapse
|
59
|
Avolio E, Caputo M, Madeddu P. Stem cell therapy and tissue engineering for correction of congenital heart disease. Front Cell Dev Biol 2015; 3:39. [PMID: 26176009 PMCID: PMC4485350 DOI: 10.3389/fcell.2015.00039] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2015] [Accepted: 06/10/2015] [Indexed: 01/08/2023] Open
Abstract
This review article reports on the new field of stem cell therapy and tissue engineering and its potential on the management of congenital heart disease. To date, stem cell therapy has mainly focused on treatment of ischemic heart disease and heart failure, with initial indication of safety and mild-to-moderate efficacy. Preclinical studies and initial clinical trials suggest that the approach could be uniquely suited for the correction of congenital defects of the heart. The basic concept is to create living material made by cellularized grafts that, once implanted into the heart, grows and remodels in parallel with the recipient organ. This would make a substantial improvement in current clinical management, which often requires repeated surgical corrections for failure of implanted grafts. Different types of stem cells have been considered and the identification of specific cardiac stem cells within the heterogeneous population of mesenchymal and stromal cells offers opportunities for de novo cardiomyogenesis. In addition, endothelial cells and vascular progenitors, including cells with pericyte characteristics, may be necessary to generate efficiently perfused grafts. The implementation of current surgical grafts by stem cell engineering could address the unmet clinical needs of patients with congenital heart defects.
Collapse
Affiliation(s)
- Elisa Avolio
- Division of Experimental Cardiovascular Medicine, School of Clinical Sciences, Bristol Heart Institute, University of Bristol Bristol, UK
| | - Massimo Caputo
- Congenital Heart Surgery, School of Clinical Sciences, Bristol Heart Institute, University of Bristol Bristol, UK
| | - Paolo Madeddu
- Division of Experimental Cardiovascular Medicine, School of Clinical Sciences, Bristol Heart Institute, University of Bristol Bristol, UK
| |
Collapse
|
60
|
Cheung DY, Duan B, Butcher JT. Current progress in tissue engineering of heart valves: multiscale problems, multiscale solutions. Expert Opin Biol Ther 2015; 15:1155-72. [PMID: 26027436 DOI: 10.1517/14712598.2015.1051527] [Citation(s) in RCA: 99] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
INTRODUCTION Heart valve disease is an increasingly prevalent and clinically serious condition. There are no clinically effective biological diagnostics or treatment strategies. The only recourse available is replacement with a prosthetic valve, but the inability of these devices to grow or respond biologically to their environments necessitates multiple resizing surgeries and life-long coagulation treatment, especially in children. Tissue engineering has a unique opportunity to impact heart valve disease by providing a living valve conduit, capable of growth and biological integration. AREAS COVERED This review will cover current tissue engineering strategies in fabricating heart valves and their progress towards the clinic, including molded scaffolds using naturally derived or synthetic polymers, decellularization, electrospinning, 3D bioprinting, hybrid techniques, and in vivo engineering. EXPERT OPINION Whereas much progress has been made to create functional living heart valves, a clinically viable product is not yet realized. The next leap in engineered living heart valves will require a deeper understanding of how the natural multi-scale structural and biological heterogeneity of the tissue ensures its efficient function. Related, improved fabrication strategies must be developed that can replicate this de novo complexity, which is likely instructive for appropriate cell differentiation and remodeling whether seeded with autologous stem cells in vitro or endogenously recruited cells.
Collapse
Affiliation(s)
- Daniel Y Cheung
- Cornell University, Department of Biomedical Engineering , Ithaca, NY , USA
| | | | | |
Collapse
|
61
|
Abstract
The use of bioprosthetic valves fabricated from fixed heterograft tissue (porcine aortic valves or bovine pericardium) in heart valve replacement surgery is limited because of calcification-related failures. The mechanism of calcification of bioprosthetic valves is quite complex and has a variety of determinants, including host factors, tissue fixation conditions, and mechanical effects. Currently, there is no effective therapy to prevent calcification in clinical settings. This article reviews a variety of anticalcification strategies that are under investigation either in advanced animal models or in clinical trials. Bisphosphonates, such as ethan hydroxybisphosphonate (EHBP), inhibit calcium phosphate crystal formation. However, because of their systemic toxicity, they are used as either tissue treatments or polymeric site-specific delivery systems. Detergent treatment, such as sodium dodecyl sulfate (SDS), extracts almost all phospholipids from bioprosthetic heart valve cuspal tissue. Procedures, such as amino oleic acid pretreatment, inhibit calcium uptake. Polyurethane trileaflet valves, investigated as alternatives to bioprosthetic or mechanical valve prostheses, undergo intrinsic and thrombus-related calcification and degradation. Calcification- and thrombus-resistant polyurethanes synthesized in our laboratory by covalent linking of EHBP or heparin (either in bulk or on surface) by unique polyepoxidation chemistry are attractive candidates for further research. Tissue-engineered heart valves may have an important place in the future.
Collapse
|
62
|
Duan B, Hockaday LA, Das S, Xu C, Butcher JT. Comparison of Mesenchymal Stem Cell Source Differentiation Toward Human Pediatric Aortic Valve Interstitial Cells within 3D Engineered Matrices. Tissue Eng Part C Methods 2015; 21:795-807. [PMID: 25594437 DOI: 10.1089/ten.tec.2014.0589] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
Living tissue-engineered heart valves (TEHV) would be a major benefit for children who require a replacement with the capacity for growth and biological integration. A persistent challenge for TEHV is accessible human cell source(s) that can mimic native valve cell phenotypes and matrix remodeling characteristics that are essential for long-term function. Mesenchymal stem cells derived from bone marrow (BMMSC) or adipose tissue (ADMSC) are intriguing cell sources for TEHV, but they have not been compared with pediatric human aortic valve interstitial cells (pHAVIC) in relevant 3D environments. In this study, we compared the spontaneous and induced multipotency of ADMSC and BMMSC with that of pHAVIC using different induction media within three-dimensional (3D) bioactive hybrid hydrogels with material modulus comparable to that of aortic heart valve leaflets. pHAVIC possessed some multi-lineage differentiation capacity in response to induction media, but limited to the earliest stages and much less potent than either ADMSC or BMMSC. ADMSC expressed cell phenotype markers more similar to pHAVIC when conditioned in basic fibroblast growth factor (bFGF) containing HAVIC growth medium, while BMMSC generally expressed similar extracellular matrix remodeling characteristics to pHAVIC. Finally, we covalently attached bFGF to PEG monoacrylate linkers and further covalently immobilized in the 3D hybrid hydrogels. Immobilized bFGF upregulated vimentin expression and promoted the fibroblastic differentiation of pHAVIC, ADMSC, and BMMSC. These findings suggest that stem cells retain a heightened capacity for osteogenic differentiation in 3D culture, but can be shifted toward fibroblast differentiation through matrix tethering of bFGF. Such a strategy is likely important for utilizing stem cell sources in heart valve tissue engineering applications.
Collapse
Affiliation(s)
- Bin Duan
- 1 Department of Biomedical Engineering, Cornell University , Ithaca, New York
| | - Laura A Hockaday
- 1 Department of Biomedical Engineering, Cornell University , Ithaca, New York
| | - Shoshana Das
- 2 Department of Biological and Environmental Engineering, Cornell University , Ithaca, New York
| | - Charlie Xu
- 2 Department of Biological and Environmental Engineering, Cornell University , Ithaca, New York
| | - Jonathan T Butcher
- 1 Department of Biomedical Engineering, Cornell University , Ithaca, New York
| |
Collapse
|
63
|
A review of: Application of synthetic scaffold in tissue engineering heart valves. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 48:556-65. [DOI: 10.1016/j.msec.2014.12.016] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2014] [Revised: 08/26/2014] [Accepted: 12/05/2014] [Indexed: 01/28/2023]
|
64
|
Jana S, Tranquillo RT, Lerman A. Cells for tissue engineering of cardiac valves. J Tissue Eng Regen Med 2015; 10:804-824. [DOI: 10.1002/term.2010] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2014] [Revised: 12/15/2014] [Accepted: 01/12/2015] [Indexed: 12/20/2022]
Affiliation(s)
- Soumen Jana
- Division of Cardiovascular Diseases; Mayo Clinic; Rochester MN USA
| | - Robert T. Tranquillo
- Department of Biomedical Engineering; University of Minnesota; Minneapolis MN USA
| | - Amir Lerman
- Division of Cardiovascular Diseases; Mayo Clinic; Rochester MN USA
| |
Collapse
|
65
|
Smit FE, Dohmen PM. Cardiovascular tissue engineering: where we come from and where are we now? Med Sci Monit Basic Res 2015; 21:1-3. [PMID: 25623227 PMCID: PMC4316861 DOI: 10.12659/msmbr.893546] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Tissue engineering was introduced by Vacanti and Langer in the 80’s, exploring the potential of this new technology starting with the well-known “human ear on the mouse back”. The goal is to create a substitute which supplies an individual therapy for patients with regeneration, remodeling and growth potential. The growth potential of these subjects is of special interest in congenital cardiac surgery, avoiding repeated interventions and surgery. Initial applications of tissue engineered created substitutes were relatively simple cardiovascular grafts seeded initially by end-differentiated autologous endothelial cells. Important data were collected from these initial clinical autologous endothelial cell seeded grafts in peripheral and coronary vessel disease. After these initial successfully implantation bone marrow cell were used to seed patches and pulmonary conduits were implanted in patients. Driven by the positive results of tissue engineered material implanted under low pressure circumstances, first tissue engineered patches were implanted in the systemic circulation followed by the implantation of tissue engineered aortic heart valves. Tissue engineering is an extreme dynamic technology with continuously modifications and improvements to optimize clinical products. New technologies are unified and so this has also be done with tissue engineering and new application features, so called transcatheter valve intervention. First studies are initiated to apply tissue engineered heart valves with this new transcatheter delivery system less invasive. Simultaneously studies have been started on tissue engineering of so-called whole organs since organ transplantation is restricted due to donor shortage and tissue engineering could overcome this problem. Initial studies of whole heart engineering in the rat model are promising and larger size models are initiated.
Collapse
Affiliation(s)
- Francis E Smit
- Department of Cardiothoracic Surgery, University of the Free State, Bloemfontein, South Africa
| | - Pascal M Dohmen
- Department of Cardiothoracic Surgery, University of the Free State, Bloemfontein, South Africa
| |
Collapse
|
66
|
Moreira R, Velz T, Alves N, Gesche VN, Malischewski A, Schmitz-Rode T, Frese J, Jockenhoevel S, Mela P. Tissue-engineered heart valve with a tubular leaflet design for minimally invasive transcatheter implantation. Tissue Eng Part C Methods 2014; 21:530-40. [PMID: 25380414 DOI: 10.1089/ten.tec.2014.0214] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
Transcatheter aortic valve implantation of (nonviable) bioprosthetic valves has been proven a valid alternative to conventional surgical implantation in patients at high or prohibitive mortality risk. In this study we present the in vitro proof-of-principle of a newly developed tissue-engineered heart valve for minimally invasive implantation, with the ultimate aim of adding the unique advantages of a living tissue with regeneration capabilities to the continuously developing transcatheter technologies. The tube-in-stent is a fibrin-based tissue-engineered valve with a tubular leaflet design. It consists of a tubular construct sewn into a self-expandable nitinol stent at three commissural attachment points and along a circumferential line so that it forms three coaptating leaflets by collapsing under diastolic back pressure. The tubular constructs were molded with fibrin and human umbilical vein cells. After 3 weeks of conditioning in a bioreactor, the valves were fully functional with unobstructed opening (systolic phase) and complete closure (diastolic phase). Tissue analysis showed a homogeneous cell distribution throughout the valve's thickness and deposition of collagen types I and III oriented along the longitudinal direction. Immunohistochemical staining against CD31 and scanning electron microscopy revealed a confluent endothelial cell layer on the surface of the valves. After harvesting, the valves underwent crimping for 20 min to simulate the catheter-based delivery. This procedure did not affect the valvular functionality in terms of orifice area during systole and complete closure during diastole. No influence on the extracellular matrix organization, as assessed by immunohistochemistry, nor on the mechanical properties was observed. These results show the potential of combining tissue engineering and minimally invasive implantation technology to obtain a living heart valve with a simple and robust tubular design for transcatheter delivery. The effect of the in vivo remodeling on the functionality of the tube-in-stent valve remains to be tested.
Collapse
Affiliation(s)
- Ricardo Moreira
- 1Department of Tissue Engineering and Textile Implants, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Thaddaeus Velz
- 1Department of Tissue Engineering and Textile Implants, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Nuno Alves
- 1Department of Tissue Engineering and Textile Implants, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | | | - Axel Malischewski
- 1Department of Tissue Engineering and Textile Implants, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Thomas Schmitz-Rode
- 1Department of Tissue Engineering and Textile Implants, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Julia Frese
- 1Department of Tissue Engineering and Textile Implants, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Stefan Jockenhoevel
- 1Department of Tissue Engineering and Textile Implants, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany.,2Institut für Textiltechnik, RWTH Aachen University, Aachen, Germany
| | - Petra Mela
- 1Department of Tissue Engineering and Textile Implants, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
67
|
Emerging Trends in Heart Valve Engineering: Part I. Solutions for Future. Ann Biomed Eng 2014; 43:833-43. [DOI: 10.1007/s10439-014-1209-z] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2014] [Accepted: 12/02/2014] [Indexed: 10/24/2022]
|
68
|
MacGrogan D, Luxán G, Driessen-Mol A, Bouten C, Baaijens F, de la Pompa JL. How to make a heart valve: from embryonic development to bioengineering of living valve substitutes. Cold Spring Harb Perspect Med 2014; 4:a013912. [PMID: 25368013 DOI: 10.1101/cshperspect.a013912] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Cardiac valve disease is a significant cause of ill health and death worldwide, and valve replacement remains one of the most common cardiac interventions in high-income economies. Despite major advances in surgical treatment, long-term therapy remains inadequate because none of the current valve substitutes have the potential for remodeling, regeneration, and growth of native structures. Valve development is coordinated by a complex interplay of signaling pathways and environmental cues that cause disease when perturbed. Cardiac valves develop from endocardial cushions that become populated by valve precursor mesenchyme formed by an epithelial-mesenchymal transition (EMT). The mesenchymal precursors, subsequently, undergo directed growth, characterized by cellular compartmentalization and layering of a structured extracellular matrix (ECM). Knowledge gained from research into the development of cardiac valves is driving exploration into valve biomechanics and tissue engineering directed at creating novel valve substitutes endowed with native form and function.
Collapse
Affiliation(s)
- Donal MacGrogan
- Program of Cardiovascular Developmental Biology, Department of Cardiovascular Development and Repair, Centro Nacional de Investigaciones Cardiovasculares (CNIC), 28029 Madrid, Spain
| | - Guillermo Luxán
- Program of Cardiovascular Developmental Biology, Department of Cardiovascular Development and Repair, Centro Nacional de Investigaciones Cardiovasculares (CNIC), 28029 Madrid, Spain
| | - Anita Driessen-Mol
- Biomedical Engineering/Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands
| | - Carlijn Bouten
- Biomedical Engineering/Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands
| | - Frank Baaijens
- Biomedical Engineering/Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands
| | - José Luis de la Pompa
- Program of Cardiovascular Developmental Biology, Department of Cardiovascular Development and Repair, Centro Nacional de Investigaciones Cardiovasculares (CNIC), 28029 Madrid, Spain
| |
Collapse
|
69
|
Khorramirouz R, Sabetkish S, Akbarzadeh A, Muhammadnejad A, Heidari R, Kajbafzadeh AM. Effect of three decellularisation protocols on the mechanical behaviour and structural properties of sheep aortic valve conduits. Adv Med Sci 2014; 59:299-307. [PMID: 25260036 DOI: 10.1016/j.advms.2014.08.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2014] [Revised: 08/09/2014] [Accepted: 08/13/2014] [Indexed: 11/16/2022]
Abstract
PURPOSE To determine the best method for decellularisation of aortic valve conduits (AVCs) that efficiently removes the cells while preserving the extracellular matrix (ECM) by examining the valvular and conduit sections separately. MATERIAL/METHODS Sheep AVCs were decellularised by using three different protocols: detergent-based (1% SDS+1% SDC), detergent and enzyme-based (Triton+EDTA+RNase and DNase), and enzyme-based (Trypsin+RNase and DNase) methods. The efficacy of the decellularisation methods to completely remove the cells while preserving the ECM was evaluated by histological evaluation, scanning electron microscopy (SEM), hydroxyproline analysis, tensile test, and DAPI staining. RESULTS The detergent-based method completely removed the cells and left the ECM and collagen content in the valve and conduit sections relatively well preserved. The detergent and enzyme-based protocol did not completely remove the cells, but left the collagen content in both sections well preserved. ECM deterioration was observed in the aortic valves (AVs), but the ultrastructure of the conduits was well preserved, with no media distortion. The enzyme-based protocol removed the cells relatively well; however, mild structural distortion and poor collagen content was observed in the AVs. Incomplete cell removal (better than that observed with the detergent and enzyme-based protocol), poor collagen preservation, and mild structural distortion were observed in conduits treated with the enzyme-based method. CONCLUSIONS The results suggested that the detergent-based methods are the most effective protocols for cell removal and ECM preservation of AVCs. The AVCs treated with this detergent-based method may be excellent scaffolds for recellularisation.
Collapse
Affiliation(s)
- Reza Khorramirouz
- Pediatric Urology Research Center, Section of Tissue Engineering and Stem Cells Therapy, Children's Hospital Medical Center, Tehran University of Medical Sciences, Tehran, Iran
| | - Shabnam Sabetkish
- Pediatric Urology Research Center, Section of Tissue Engineering and Stem Cells Therapy, Children's Hospital Medical Center, Tehran University of Medical Sciences, Tehran, Iran
| | - Aram Akbarzadeh
- Pediatric Urology Research Center, Section of Tissue Engineering and Stem Cells Therapy, Children's Hospital Medical Center, Tehran University of Medical Sciences, Tehran, Iran
| | - Ahad Muhammadnejad
- Cancer Research Center, Iranian Cancer Institute, Department of Pathology, Tehran University of Medical Sciences, Tehran, Iran
| | - Reza Heidari
- Pediatric Urology Research Center, Section of Tissue Engineering and Stem Cells Therapy, Children's Hospital Medical Center, Tehran University of Medical Sciences, Tehran, Iran
| | - Abdol-Mohammad Kajbafzadeh
- Pediatric Urology Research Center, Section of Tissue Engineering and Stem Cells Therapy, Children's Hospital Medical Center, Tehran University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
70
|
Dubé J, Bourget JM, Gauvin R, Lafrance H, Roberge CJ, Auger FA, Germain L. Progress in developing a living human tissue-engineered tri-leaflet heart valve assembled from tissue produced by the self-assembly approach. Acta Biomater 2014; 10:3563-70. [PMID: 24813743 DOI: 10.1016/j.actbio.2014.04.033] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2013] [Revised: 04/17/2014] [Accepted: 04/28/2014] [Indexed: 11/15/2022]
Abstract
The aortic heart valve is constantly subjected to pulsatile flow and pressure gradients which, associated with cardiovascular risk factors and abnormal hemodynamics (i.e. altered wall shear stress), can cause stenosis and calcification of the leaflets and result in valve malfunction and impaired circulation. Available options for valve replacement include homograft, allogenic or xenogenic graft as well as the implantation of a mechanical valve. A tissue-engineered heart valve containing living autologous cells would represent an alternative option, particularly for pediatric patients, but still needs to be developed. The present study was designed to demonstrate the feasibility of using a living tissue sheet produced by the self-assembly method, to replace the bovine pericardium currently used for the reconstruction of a stented human heart valve. In this study, human fibroblasts were cultured in the presence of sodium ascorbate to produce tissue sheets. These sheets were superimposed to create a thick construct. Tissue pieces were cut from these constructs and assembled together on a stent, based on techniques used for commercially available replacement valves. Histology and transmission electron microscopy analysis showed that the fibroblasts were embedded in a dense extracellular matrix produced in vitro. The mechanical properties measured were consistent with the fact that the engineered tissue was resistant and could be cut, sutured and assembled on a wire frame typically used in bioprosthetic valve assembly. After a culture period in vitro, the construct was cohesive and did not disrupt or disassemble. The tissue engineered heart valve was stimulated in a pulsatile flow bioreactor and was able to sustain multiple duty cycles. This prototype of a tissue-engineered heart valve containing cells embedded in their own extracellular matrix and sewn on a wire frame has the potential to be strong enough to support physiological stress. The next step will be to test this valve extensively in a bioreactor and at a later date, in a large animal model in order to assess in vivo patency of the graft.
Collapse
Affiliation(s)
- Jean Dubé
- Centre d'organogénèse expérimentale de l'Université Laval/LOEX, Centre de recherche FRQS du Centre hospitalier universitaire (CHU) de Québec, 1401, 18(eme) rue, G1J 1Z4 Québec, QC, Canada; Département de Chirurgie, Faculté de Médecine, Université Laval, 1050 Avenue de la Médecine, G1V 0A6 Québec, QC, Canada
| | - Jean-Michel Bourget
- Centre d'organogénèse expérimentale de l'Université Laval/LOEX, Centre de recherche FRQS du Centre hospitalier universitaire (CHU) de Québec, 1401, 18(eme) rue, G1J 1Z4 Québec, QC, Canada; Département de Chirurgie, Faculté de Médecine, Université Laval, 1050 Avenue de la Médecine, G1V 0A6 Québec, QC, Canada
| | - Robert Gauvin
- Centre d'organogénèse expérimentale de l'Université Laval/LOEX, Centre de recherche FRQS du Centre hospitalier universitaire (CHU) de Québec, 1401, 18(eme) rue, G1J 1Z4 Québec, QC, Canada; Département de Chirurgie, Faculté de Médecine, Université Laval, 1050 Avenue de la Médecine, G1V 0A6 Québec, QC, Canada
| | - Hugues Lafrance
- Edwards Lifesciences LLC, One Edwards Way, Irvine, CA 92614, USA
| | - Charles J Roberge
- Centre d'organogénèse expérimentale de l'Université Laval/LOEX, Centre de recherche FRQS du Centre hospitalier universitaire (CHU) de Québec, 1401, 18(eme) rue, G1J 1Z4 Québec, QC, Canada; Département de Chirurgie, Faculté de Médecine, Université Laval, 1050 Avenue de la Médecine, G1V 0A6 Québec, QC, Canada
| | - François A Auger
- Centre d'organogénèse expérimentale de l'Université Laval/LOEX, Centre de recherche FRQS du Centre hospitalier universitaire (CHU) de Québec, 1401, 18(eme) rue, G1J 1Z4 Québec, QC, Canada; Département de Chirurgie, Faculté de Médecine, Université Laval, 1050 Avenue de la Médecine, G1V 0A6 Québec, QC, Canada
| | - Lucie Germain
- Centre d'organogénèse expérimentale de l'Université Laval/LOEX, Centre de recherche FRQS du Centre hospitalier universitaire (CHU) de Québec, 1401, 18(eme) rue, G1J 1Z4 Québec, QC, Canada; Département de Chirurgie, Faculté de Médecine, Université Laval, 1050 Avenue de la Médecine, G1V 0A6 Québec, QC, Canada.
| |
Collapse
|
71
|
Lee YU, Yi T, James I, Tara S, Stuber AJ, Shah KV, Lee AY, Sugiura T, Hibino N, Shinoka T, Breuer CK. Transplantation of pulmonary valve using a mouse model of heterotopic heart transplantation. J Vis Exp 2014. [PMID: 25079013 DOI: 10.3791/51695] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Tissue engineered heart valves, especially decellularized valves, are starting to gain momentum in clinical use of reconstructive surgery with mixed results. However, the cellular and molecular mechanisms of the neotissue development, valve thickening, and stenosis development are not researched extensively. To answer the above questions, we developed a murine heterotopic heart valve transplantation model. A heart valve was harvested from a valve donor mouse and transplanted to a heart donor mouse. The heart with a new valve was transplanted heterotopically to a recipient mouse. The transplanted heart showed its own heartbeat, independent of the recipient's heartbeat. The blood flow was quantified using a high frequency ultrasound system with a pulsed wave Doppler. The flow through the implanted pulmonary valve showed forward flow with minimal regurgitation and the peak flow was close to 100 mm/sec. This murine model of heart valve transplantation is highly versatile, so it can be modified and adapted to provide different hemodynamic environments and/or can be used with various transgenic mice to study neotissue development in a tissue engineered heart valve.
Collapse
Affiliation(s)
- Yong-Ung Lee
- Tissue Engineering Program and Surgical Research, Nationwide Children's Hospital;
| | - Tai Yi
- Tissue Engineering Program and Surgical Research, Nationwide Children's Hospital
| | - Iyore James
- Tissue Engineering Program and Surgical Research, Nationwide Children's Hospital
| | - Shuhei Tara
- Tissue Engineering Program and Surgical Research, Nationwide Children's Hospital
| | - Alexander J Stuber
- Tissue Engineering Program and Surgical Research, Nationwide Children's Hospital
| | - Kejal V Shah
- Tissue Engineering Program and Surgical Research, Nationwide Children's Hospital
| | - Avione Y Lee
- Tissue Engineering Program and Surgical Research, Nationwide Children's Hospital
| | - Tadahisa Sugiura
- Tissue Engineering Program and Surgical Research, Nationwide Children's Hospital
| | | | - Toshiharu Shinoka
- Tissue Engineering Program and Surgical Research, Nationwide Children's Hospital
| | - Christopher K Breuer
- Tissue Engineering Program and Surgical Research, Nationwide Children's Hospital; Pediatric Surgery, Nationwide Children's Hospital
| |
Collapse
|
72
|
Jana S, Tefft BJ, Spoon DB, Simari RD. Scaffolds for tissue engineering of cardiac valves. Acta Biomater 2014; 10:2877-93. [PMID: 24675108 DOI: 10.1016/j.actbio.2014.03.014] [Citation(s) in RCA: 94] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2013] [Revised: 02/25/2014] [Accepted: 03/12/2014] [Indexed: 01/09/2023]
Abstract
Tissue engineered heart valves offer a promising alternative for the replacement of diseased heart valves avoiding the limitations faced with currently available bioprosthetic and mechanical heart valves. In the paradigm of tissue engineering, a three-dimensional platform - the so-called scaffold - is essential for cell proliferation, growth and differentiation, as well as the ultimate generation of a functional tissue. A foundation for success in heart valve tissue engineering is a recapitulation of the complex design and diverse mechanical properties of a native valve. This article reviews technological details of the scaffolds that have been applied to date in heart valve tissue engineering research.
Collapse
Affiliation(s)
- S Jana
- Division of Cardiovascular Diseases, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA
| | - B J Tefft
- Division of Cardiovascular Diseases, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA
| | - D B Spoon
- Division of Cardiovascular Diseases, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA
| | - R D Simari
- Division of Cardiovascular Diseases, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA.
| |
Collapse
|
73
|
Masoumi N, Annabi N, Assmann A, Larson BL, Hjortnaes J, Alemdar N, Kharaziha M, Manning KB, Mayer JE, Khademhosseini A. Tri-layered elastomeric scaffolds for engineering heart valve leaflets. Biomaterials 2014; 35:7774-85. [PMID: 24947233 DOI: 10.1016/j.biomaterials.2014.04.039] [Citation(s) in RCA: 111] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2014] [Accepted: 04/14/2014] [Indexed: 12/12/2022]
Abstract
Tissue engineered heart valves (TEHVs) that can grow and remodel have the potential to serve as permanent replacements of the current non-viable prosthetic valves particularly for pediatric patients. A major challenge in designing functional TEHVs is to mimic both structural and anisotropic mechanical characteristics of the native valve leaflets. To establish a more biomimetic model of TEHV, we fabricated tri-layered scaffolds by combining electrospinning and microfabrication techniques. These constructs were fabricated by assembling microfabricated poly(glycerol sebacate) (PGS) and fibrous PGS/poly(caprolactone) (PCL) electrospun sheets to develop elastic scaffolds with tunable anisotropic mechanical properties similar to the mechanical characteristics of the native heart valves. The engineered scaffolds supported the growth of valvular interstitial cells (VICs) and mesenchymal stem cells (MSCs) within the 3D structure and promoted the deposition of heart valve extracellular matrix (ECM). MSCs were also organized and aligned along the anisotropic axes of the engineered tri-layered scaffolds. In addition, the fabricated constructs opened and closed properly in an ex vivo model of porcine heart valve leaflet tissue replacement. The engineered tri-layered scaffolds have the potential for successful translation towards TEHV replacements.
Collapse
Affiliation(s)
- Nafiseh Masoumi
- Biomaterials Innovation Research Center, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, 65 Landsdowne Street, Cambridge, MA 02139, USA; Department of Cardiac Surgery, Boston Children's Hospital and Harvard Medical School, 300 Longwood Avenue, Boston, MA 02115, USA; Department of Bioengineering, The Pennsylvania State University, 205 Hallowell Building, State College, PA 16802, USA; Harvard-MIT Division of Health Sciences and Technology and The David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, 500 Main Street, Cambridge, MA 02139, USA
| | - Nasim Annabi
- Biomaterials Innovation Research Center, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, 65 Landsdowne Street, Cambridge, MA 02139, USA; Wyss Institute for Biologically Inspired Engineering, Harvard University, 3 Blackfan Circle, Boston, MA 02115, USA
| | - Alexander Assmann
- Biomaterials Innovation Research Center, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, 65 Landsdowne Street, Cambridge, MA 02139, USA; Wyss Institute for Biologically Inspired Engineering, Harvard University, 3 Blackfan Circle, Boston, MA 02115, USA; Department of Cardiovascular Surgery and Research Group for Experimental Surgery, Heinrich Heine University, Medical Faculty, Moorenstr. 5, Dusseldorf 40225, Germany
| | - Benjamin L Larson
- Harvard-MIT Division of Health Sciences and Technology and The David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, 500 Main Street, Cambridge, MA 02139, USA
| | - Jesper Hjortnaes
- Biomaterials Innovation Research Center, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, 65 Landsdowne Street, Cambridge, MA 02139, USA; Department of Cardiothoracic Surgery, University Medical Center Utrecht, Heidelberglaan 100, Utrecht, Netherlands
| | - Neslihan Alemdar
- Biomaterials Innovation Research Center, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, 65 Landsdowne Street, Cambridge, MA 02139, USA
| | - Mahshid Kharaziha
- Biomaterials Innovation Research Center, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, 65 Landsdowne Street, Cambridge, MA 02139, USA
| | - Keefe B Manning
- Department of Bioengineering, The Pennsylvania State University, 205 Hallowell Building, State College, PA 16802, USA
| | - John E Mayer
- Department of Cardiac Surgery, Boston Children's Hospital and Harvard Medical School, 300 Longwood Avenue, Boston, MA 02115, USA.
| | - Ali Khademhosseini
- Biomaterials Innovation Research Center, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, 65 Landsdowne Street, Cambridge, MA 02139, USA; Wyss Institute for Biologically Inspired Engineering, Harvard University, 3 Blackfan Circle, Boston, MA 02115, USA; Department of Physics, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21569, Saudi Arabia.
| |
Collapse
|
74
|
Masoumi N, Howell MC, Johnson KL, Niesslein MJ, Gerber G, Engelmayr GC. Design and testing of a cyclic stretch and flexure bioreactor for evaluating engineered heart valve tissues based on poly(glycerol sebacate) scaffolds. Proc Inst Mech Eng H 2014; 228:576-586. [PMID: 24898445 DOI: 10.1177/0954411914534837] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Cyclic flexure and stretch are essential to the function of semilunar heart valves and have demonstrated utility in mechanically conditioning tissue-engineered heart valves. In this study, a cyclic stretch and flexure bioreactor was designed and tested in the context of the bioresorbable elastomer poly(glycerol sebacate). Solid poly(glycerol sebacate) membranes were subjected to cyclic stretch, and micromolded poly(glycerol sebacate) scaffolds seeded with porcine aortic valvular interstitial cells were subjected to cyclic stretch and flexure. The results demonstrated significant effects of cyclic stretch on poly(glycerol sebacate) mechanical properties, including significant decreases in effective stiffness versus controls. In valvular interstitial cell-seeded scaffolds, cyclic stretch elicited significant increases in DNA and collagen content that paralleled maintenance of effective stiffness. This work provides a basis for investigating the roles of mechanical loading in the formation of tissue-engineered heart valves based on elastomeric scaffolds.
Collapse
Affiliation(s)
- Nafiseh Masoumi
- Department of Bioengineering, The Pennsylvania State University, University Park, PA, USA
| | - M Christian Howell
- Department of Bioengineering, The Pennsylvania State University, University Park, PA, USA
| | - Katherine L Johnson
- Department of Bioengineering, The Pennsylvania State University, University Park, PA, USA
| | - Matthew J Niesslein
- Department of Bioengineering, The Pennsylvania State University, University Park, PA, USA
| | - Gene Gerber
- Department of Bioengineering, The Pennsylvania State University, University Park, PA, USA
| | - George C Engelmayr
- Department of Bioengineering, The Pennsylvania State University, University Park, PA, USA
| |
Collapse
|
75
|
Wong ML, Griffiths LG. Immunogenicity in xenogeneic scaffold generation: antigen removal vs. decellularization. Acta Biomater 2014; 10:1806-16. [PMID: 24486910 DOI: 10.1016/j.actbio.2014.01.028] [Citation(s) in RCA: 183] [Impact Index Per Article: 16.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2013] [Revised: 12/15/2013] [Accepted: 01/23/2014] [Indexed: 12/11/2022]
Abstract
Decades of research have been undertaken towards the goal of tissue engineering using xenogeneic scaffolds. The primary advantages associated with use of xenogeneic tissue-derived scaffolds for in vitro development of replacement tissues and organs stem from the inherent extracellular matrix (ECM) composition and architecture. Native ECM possesses appropriate mechanical properties for physiological function of the biomaterial and signals for cell binding, growth and differentiation. Additionally, xenogeneic tissue is readily available. However, translation of xenogeneic scaffold-derived engineered tissues or organs into clinical therapies requires xenoantigenicity of the material to be adequately addressed prior to implantation. Failure to achieve this goal will result in a graft-specific host immune rejection response, jeopardizing in vivo survival of the resultant scaffold, tissue or organ. This review explores (i) the appropriateness of scaffold acellularity as an outcome measure for assessing reduction of the immunological barriers to the use of xenogeneic scaffolds for tissue engineering applications and (ii) the need for tissue engineers to strive for antigen removal during xenogeneic scaffold generation.
Collapse
Affiliation(s)
- Maelene L Wong
- Department of Veterinary Medicine: Medicine and Epidemiology, University of California, Davis, One Shields Ave., Davis, CA 95616, USA; Department of Biomedical Engineering, University of California, Davis, One Shields Ave., Davis, CA 95616, USA
| | - Leigh G Griffiths
- Department of Veterinary Medicine: Medicine and Epidemiology, University of California, Davis, One Shields Ave., Davis, CA 95616, USA.
| |
Collapse
|
76
|
Regenerative implants for cardiovascular tissue engineering. Transl Res 2014; 163:321-41. [PMID: 24589506 DOI: 10.1016/j.trsl.2014.01.014] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2013] [Revised: 01/27/2014] [Accepted: 01/27/2014] [Indexed: 01/22/2023]
Abstract
A fundamental problem that affects the field of cardiovascular surgery is the paucity of autologous tissue available for surgical reconstructive procedures. Although the best results are obtained when an individual's own tissues are used for surgical repair, this is often not possible as a result of pathology of autologous tissues or lack of a compatible replacement source from the body. The use of prosthetics is a popular solution to overcome shortage of autologous tissue, but implantation of these devices comes with an array of additional problems and complications related to biocompatibility. Transplantation offers another option that is widely used but complicated by problems related to rejection and donor organ scarcity. The field of tissue engineering represents a promising new option for replacement surgical procedures. Throughout the years, intensive interdisciplinary, translational research into cardiovascular regenerative implants has been undertaken in an effort to improve surgical outcome and better quality of life for patients with cardiovascular defects. Vascular, valvular, and heart tissue repair are the focus of these efforts. Implants for these neotissues can be divided into 2 groups: biologic and synthetic. These materials are used to facilitate the delivery of cells or drugs to diseased, damaged, or absent tissue. Furthermore, they can function as a tissue-forming device used to enhance the body's own repair mechanisms. Various preclinical studies and clinical trials using these advances have shown that tissue-engineered materials are a viable option for surgical repair, but require refinement if they are going to reach their clinical potential. With the growth and accomplishments this field has already achieved, meeting those goals in the future should be attainable.
Collapse
|
77
|
Weber M, Heta E, Moreira R, Gesche VN, Schermer T, Frese J, Jockenhoevel S, Mela P. Tissue-engineered fibrin-based heart valve with a tubular leaflet design. Tissue Eng Part C Methods 2014; 20:265-75. [PMID: 23829551 PMCID: PMC3968886 DOI: 10.1089/ten.tec.2013.0258] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2013] [Accepted: 06/26/2013] [Indexed: 11/12/2022] Open
Abstract
The general approach in heart valve tissue engineering is to mimic the shape of the native valve in the attempt to recreate the natural haemodynamics. In this article, we report the fabrication of the first tissue-engineered heart valve (TEHV) based on a tubular leaflet design, where the function of the leaflets of semilunar heart valves is performed by a simple tubular construct sutured along a circumferential line at the root and at three single points at the sinotubular junction. The tubular design is a recent development in pericardial (nonviable) bioprostheses, which has attracted interest because of the simplicity of the construction and the reliability of the implantation technique. Here we push the potential of the concept further from the fabrication and material point of view to realize the tube-in-tube valve: an autologous, living HV with remodelling and growing capability, physiological haemocompatibility, simple to construct and fast to implant. We developed two different fabrication/conditioning procedures and produced fibrin-based constructs embedding cells from the ovine umbilical cord artery according to the two different approaches. Tissue formation was confirmed by histology and immunohistology. The design of the tube-in-tube foresees the possibility of using a textile coscaffold (here demonstrated with a warp-knitted mesh) to achieve enhanced mechanical properties in vision of implantation in the aortic position. The tube-in-tube represents an attractive alternative to the conventional design of TEHVs aiming at reproducing the valvular geometry.
Collapse
Affiliation(s)
- Miriam Weber
- Department of Tissue Engineering and Textile Implants, Institute of Applied Medical Engineering, Helmholtz Institute of the RWTH Aachen University, Aachen, Germany
| | - Eriona Heta
- Department of Tissue Engineering and Textile Implants, Institute of Applied Medical Engineering, Helmholtz Institute of the RWTH Aachen University, Aachen, Germany
| | - Ricardo Moreira
- Department of Tissue Engineering and Textile Implants, Institute of Applied Medical Engineering, Helmholtz Institute of the RWTH Aachen University, Aachen, Germany
| | | | - Thomas Schermer
- Department of Tissue Engineering and Textile Implants, Institute of Applied Medical Engineering, Helmholtz Institute of the RWTH Aachen University, Aachen, Germany
| | - Julia Frese
- Department of Tissue Engineering and Textile Implants, Institute of Applied Medical Engineering, Helmholtz Institute of the RWTH Aachen University, Aachen, Germany
| | - Stefan Jockenhoevel
- Department of Tissue Engineering and Textile Implants, Institute of Applied Medical Engineering, Helmholtz Institute of the RWTH Aachen University, Aachen, Germany
- Institut für Textiltechnik, RWTH Aachen University, Aachen, Germany
| | - Petra Mela
- Department of Tissue Engineering and Textile Implants, Institute of Applied Medical Engineering, Helmholtz Institute of the RWTH Aachen University, Aachen, Germany
| |
Collapse
|
78
|
Mol A, Smits AIPM, Bouten CVC, Baaijens FPT. Tissue engineering of heart valves: advances and current challenges. Expert Rev Med Devices 2014; 6:259-75. [DOI: 10.1586/erd.09.12] [Citation(s) in RCA: 115] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
79
|
Kwon HS, Jung SG, Kim HY, Parker SA, Batt CA, Kim YR. A multi-functional polyhydroxybutyrate nanoparticle for theranostic applications. J Mater Chem B 2014; 2:3965-3971. [DOI: 10.1039/c4tb00304g] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
One-step enzymatic synthesis of theranostic PHB nanoparticles using PHA synthase fused with A33scFv and GFP.
Collapse
Affiliation(s)
- Hee-Su Kwon
- Institute of Life Sciences and Resources & Department of Food Science and Biotechnology
- College of Life Sciences
- Kyung Hee University
- Yongin, Republic of Korea
| | - Sung-Geun Jung
- Institute of Life Sciences and Resources & Department of Food Science and Biotechnology
- College of Life Sciences
- Kyung Hee University
- Yongin, Republic of Korea
| | - Hae-Yeong Kim
- Institute of Life Sciences and Resources & Department of Food Science and Biotechnology
- College of Life Sciences
- Kyung Hee University
- Yongin, Republic of Korea
| | | | - Carl A. Batt
- Graduate field of Biomedical Engineering
- Cornell University
- Ithaca, USA
- Department of Food Science
- Cornell University
| | - Young-Rok Kim
- Institute of Life Sciences and Resources & Department of Food Science and Biotechnology
- College of Life Sciences
- Kyung Hee University
- Yongin, Republic of Korea
| |
Collapse
|
80
|
Transcatheter implantation of homologous "off-the-shelf" tissue-engineered heart valves with self-repair capacity: long-term functionality and rapid in vivo remodeling in sheep. J Am Coll Cardiol 2013; 63:1320-1329. [PMID: 24361320 DOI: 10.1016/j.jacc.2013.09.082] [Citation(s) in RCA: 141] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2013] [Revised: 09/12/2013] [Accepted: 09/19/2013] [Indexed: 10/25/2022]
Abstract
OBJECTIVES This study sought to evaluate long-term in vivo functionality, host cell repopulation, and remodeling of "off-the-shelf" tissue engineered transcatheter homologous heart valves. BACKGROUND Transcatheter valve implantation has emerged as a valid alternative to conventional surgery, in particular for elderly high-risk patients. However, currently used bioprosthetic transcatheter valves are prone to progressive dysfunctional degeneration, limiting their use in younger patients. To overcome these limitations, the concept of tissue engineered heart valves with self-repair capacity has been introduced as next-generation technology. METHODS In vivo functionality, host cell repopulation, and matrix remodeling of homologous transcatheter tissue-engineered heart valves (TEHVs) was evaluated up to 24 weeks as pulmonary valve replacements (transapical access) in sheep (n = 12). As a control, tissue composition and structure were analyzed in identical not implanted TEHVs (n = 5). RESULTS Transcatheter implantation was successful in all animals. Valve functionality was excellent displaying sufficient leaflet motion and coaptation with only minor paravalvular leakage in some animals. Mild central regurgitation was detected after 8 weeks, increasing to moderate after 24 weeks, correlating to a compromised leaflet coaptation. Mean and peak transvalvular pressure gradients were 4.4 ± 1.6 mm Hg and 9.7 ± 3.0 mm Hg, respectively. Significant matrix remodeling was observed in the entire valve and corresponded with the rate of host cell repopulation. CONCLUSIONS For the first time, the feasibility and long-term functionality of transcatheter-based homologous off-the-shelf tissue engineered heart valves are demonstrated in a relevant pre-clinical model. Such engineered heart valves may represent an interesting alternative to current prostheses because of their rapid cellular repopulation, tissue remodeling, and therewith self-repair capacity. The concept of homologous off-the-shelf tissue engineered heart valves may therefore substantially simplify previous tissue engineering concepts toward clinical translation.
Collapse
|
81
|
Jia H, Caputo M, Ghorbel MT. Stem cells in vascular graft tissue engineering for congenital heart surgery. Interv Cardiol 2013. [DOI: 10.2217/ica.13.77] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
82
|
Cai J, Huang H, Zhou Y, Mei Y, Shao J, Wang Y. A new type of aortic valved stent with good stability and no influence on coronary artery. J Cardiothorac Surg 2013; 8:210. [PMID: 24219844 PMCID: PMC3842839 DOI: 10.1186/1749-8090-8-210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2013] [Accepted: 10/28/2013] [Indexed: 11/27/2022] Open
Abstract
Background To evaluated the feasibility and safety of new aortic valved stents in transcatheter aortic valve implantation (TAVI) using retrograde approach by in vitro testing and animal implantation. Materials and Methods The fluid passing test, expanding and releasing tests, static and releasing tests in tube were performed for new valved stents. Transvalvular pressure gradient, effective orifice area, pre-implantation and post-implantation regurgitant volume for the new stents were detected. Then, the new stents were implanted in six pigs using retrograde approach. These pigs were euthanized 12 h after the implantation for anatomic evaluation. Results In vitro tests showed that the closure of the new stents leaflets were effective, and stents could be released through catheter, then expanded completely and fixed fast in the tube. The coronary artery flow rates did not changed significantly after implantation (P > 0.05), while aortic regurgitant volumes were obviously reduced (P < 0.05). No significant difference in the transvalvular pressure gradient and effective orifice area of the new stents implanted within or above the valve leaflets was found (P > 0.05). In vivo experiments indicated that TAVI was successfully performed in six pigs using retrograde approach. However, one pig was died 10 h after the implantation since the stent was not expanded completely. The leaflets in stents were opening well and no valvular regurgitation was observed in the other five pigs. And thrombosis was not found. Discussion and Conclusion The new type of aortic valved stent designed in this study was characterized with good stability and could avoid the impact caused by valve leaflets on the coronary artery.
Collapse
Affiliation(s)
| | | | | | | | | | - Yongwu Wang
- Department of Thoracic and Cardiovascular Surgery, Tongji Hospital of Tongji University, Xincun Road 389, Shanghai 200065, China.
| |
Collapse
|
83
|
Martinez C, Henao A, Rodriguez JE, Padgett KR, Ramaswamy S. Monitoring Steady Flow Effects on Cell Distribution in Engineered Valve Tissues by Magnetic Resonance Imaging. Mol Imaging 2013. [DOI: 10.2310/7290.2013.00063] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Affiliation(s)
- Catalina Martinez
- From the Tissue Engineering Mechanics, Imaging and Materials Laboratory, Department of Biomedical Engineering, College of Engineering and Computing, Florida International University, and Interdisciplinary Stem Cell Institute and Department of Radiation Oncology, Miller School of Medicine, University of Miami, Miami, FL
| | - Angela Henao
- From the Tissue Engineering Mechanics, Imaging and Materials Laboratory, Department of Biomedical Engineering, College of Engineering and Computing, Florida International University, and Interdisciplinary Stem Cell Institute and Department of Radiation Oncology, Miller School of Medicine, University of Miami, Miami, FL
| | - Jose E. Rodriguez
- From the Tissue Engineering Mechanics, Imaging and Materials Laboratory, Department of Biomedical Engineering, College of Engineering and Computing, Florida International University, and Interdisciplinary Stem Cell Institute and Department of Radiation Oncology, Miller School of Medicine, University of Miami, Miami, FL
| | - Kyle R. Padgett
- From the Tissue Engineering Mechanics, Imaging and Materials Laboratory, Department of Biomedical Engineering, College of Engineering and Computing, Florida International University, and Interdisciplinary Stem Cell Institute and Department of Radiation Oncology, Miller School of Medicine, University of Miami, Miami, FL
| | - Sharan Ramaswamy
- From the Tissue Engineering Mechanics, Imaging and Materials Laboratory, Department of Biomedical Engineering, College of Engineering and Computing, Florida International University, and Interdisciplinary Stem Cell Institute and Department of Radiation Oncology, Miller School of Medicine, University of Miami, Miami, FL
| |
Collapse
|
84
|
Huang HYS, Huang S. Real-time strain mapping via biaxial stretching in heart valve tissues. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2013; 2012:6653-6. [PMID: 23367455 DOI: 10.1109/embc.2012.6347520] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Previous studies show that the collagen fiber architecture is key to the heart valves tissue mechanical property. We report a real-time strain mapping approach that provides displacement vectors and principal strain directions during the mechanical characterization of heart valve tissues. The strain maps reported in the current study allows an individual to quickly identify the approximate strain imposed on a location of the sample. The result shows that when samples are biaxially stretched under 18% strain, less anisotropy is observed in both aortic and pulmonary valve leaflet samples. Moreover, when samples are stretched from 28% to 35%, pulmonary valves leaflet samples exhibits a stronger anisotropic effect than aortic valve. Therefore, a higher degree of straightening is required for collagen fibers to be fully aligned. This work provides an easy approach to quantify mechanical properties with the corresponding strain maps of heart valve tissues and potentially facilitates the developments of tissue engineering heart valves.
Collapse
Affiliation(s)
- Hsiao-Ying Shadow Huang
- Department of Mechanical Engineering, North Carolina State University, Raleigh, NC 27695, USA.
| | | |
Collapse
|
85
|
Bouten CVC, Driessen-Mol A, Baaijens FPT. In situ heart valve tissue engineering: simple devices, smart materials, complex knowledge. Expert Rev Med Devices 2013; 9:453-5. [PMID: 23116070 DOI: 10.1586/erd.12.43] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
86
|
Tubular heart valves from decellularized engineered tissue. Ann Biomed Eng 2013; 41:2645-54. [PMID: 23897047 DOI: 10.1007/s10439-013-0872-9] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2013] [Accepted: 07/17/2013] [Indexed: 02/03/2023]
Abstract
A novel tissue-engineered heart valve (TEHV) was fabricated from a decellularized tissue tube mounted on a frame with three struts, which upon back-pressure cause the tube to collapse into three coapting "leaflets." The tissue was completely biological, fabricated from ovine fibroblasts dispersed within a fibrin gel, compacted into a circumferentially aligned tube on a mandrel, and matured using a bioreactor system that applied cyclic distension. Following decellularization, the resulting tissue possessed tensile mechanical properties, mechanical anisotropy, and collagen content that were comparable to native pulmonary valve leaflets. When mounted on a custom frame and tested within a pulse duplicator system, the tubular TEHV displayed excellent function under both aortic and pulmonary conditions, with minimal regurgitant fractions and transvalvular pressure gradients at peak systole, as well as well as effective orifice areas exceeding those of current commercially available valve replacements. Short-term fatigue testing of one million cycles with pulmonary pressure gradients was conducted without significant change in mechanical properties and no observable macroscopic tissue deterioration. This study presents an attractive potential alternative to current tissue valve replacements due to its avoidance of chemical fixation and utilization of a tissue conducive to recellularization by host cell infiltration.
Collapse
|
87
|
Abstract
The surgical repair of complex congenital heart defects frequently requires additional tissue in various forms, such as patches, conduits, and valves. These devices often require replacement over a patient's lifetime because of degeneration, calcification, or lack of growth. The main new technologies in congenital cardiac surgery aim at, on the one hand, avoiding such reoperations and, on the other hand, improving long-term outcomes of devices used to repair or replace diseased structural malformations. These technologies are: 1) new patches: CorMatrix® patches made of decellularized porcine small intestinal submucosa extracellular matrix; 2) new devices: the Melody® valve (for percutaneous pulmonary valve implantation) and tissue-engineered valved conduits (either decellularized scaffolds or polymeric scaffolds); and 3) new emerging fields, such as antenatal corrective cardiac surgery or robotically assisted congenital cardiac surgical procedures. These new technologies for structural malformation surgery are still in their infancy but certainly present great promise for the future. But the translation of these emerging technologies to routine health care and public health policy will also largely depend on economic considerations, value judgments, and political factors.
Collapse
Affiliation(s)
- David Kalfa
- Pediatric Cardiac Surgery, Columbia University, Morgan Stanley Children's Hospital of New York-Presbyterian, New York, USA
| | | |
Collapse
|
88
|
Boloori_Zadeh P, Corbett SC, Nayeb-Hashemi H. Effects of fluid flow shear rate and surface roughness on the calcification of polymeric heart valve leaflet. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2013; 33:2770-5. [DOI: 10.1016/j.msec.2013.02.042] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2012] [Revised: 02/01/2013] [Accepted: 02/23/2013] [Indexed: 10/27/2022]
|
89
|
Buber J, Bergersen L, Lock JE, Gauvreau K, Esch JJ, Landzberg MJ, Valente AM, Sandora TJ, Marshall AC. Bloodstream infections occurring in patients with percutaneously implanted bioprosthetic pulmonary valve: a single-center experience. Circ Cardiovasc Interv 2013; 6:301-10. [PMID: 23756696 DOI: 10.1161/circinterventions.112.000348] [Citation(s) in RCA: 80] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Percutaneous pulmonary valve implantation using a stent-based bioprosthetic valve provides an alternative to surgery in select patients. Systemic infections in Melody valve-implanted patients with and without identified valve involvement have been reported, yet the incidence is unknown, and risk factors remain unidentified. METHODS AND RESULTS Between 2007 and 2012, a total of 147 consecutive patients with congenital heart disease underwent Melody percutaneous pulmonary valve implantation at our institution. Demographic and clinical variables were collected at baseline and at follow-up and analyzed as predictors. The occurrence of bloodstream infection (BSI), defined as a bacterial infection treated with ≥4 weeks of antibiotics, served as our primary outcome. The mean age at implantation for the study population was 21.5±11 years, and tetralogy of Fallot was the cardiac condition in 59%. During a median follow-up of 19 months, 14 patients experienced BSI (9.5%; 95% confidence interval, 5.3%-15%). Of these, 4 (2.7%) patients had Melody valve endocarditis. Two patients died during the event, neither of whom had known valve involvement. The median procedure to infection time was 15 months (range, 1-56). In univariate analysis, male sex, previous endocarditis, in situ stents in the right ventricular outflow tract, and presence of outflow tract irregularities at the implant site were associated with BSI occurrence. CONCLUSIONS In this cohort, 9.5% of patients who underwent Melody percutaneous pulmonary valve implantation experienced subsequent BSI, occurring 1 to 56 months after implant, and 2.7% of patients had prosthetic endocarditis. Our findings suggest that patient and nonvalve anatomic factors may be associated with BSI after percutaneous pulmonary valve implantation.
Collapse
Affiliation(s)
- Jonathan Buber
- Department of Cardiology and the Division of Infectious Diseases, Departments of Medicine and Laboratory Medicine, Boston Children's Hospital, Boston, MA 02115, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
90
|
Spoon DB, Tefft BJ, Lerman A, Simari RD. Challenges of biological valve development. Interv Cardiol 2013. [DOI: 10.2217/ica.13.21] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
91
|
Masoumi N, Johnson KL, Howell MC, Engelmayr GC. Valvular interstitial cell seeded poly(glycerol sebacate) scaffolds: toward a biomimetic in vitro model for heart valve tissue engineering. Acta Biomater 2013; 9:5974-88. [PMID: 23295404 DOI: 10.1016/j.actbio.2013.01.001] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2012] [Revised: 11/24/2012] [Accepted: 01/01/2013] [Indexed: 01/01/2023]
Abstract
Tissue engineered replacement heart valves may be capable of overcoming the lack of growth potential intrinsic to current non-viable prosthetics, and thus could potentially serve as permanent replacements in the surgical repair of pediatric valvular lesions. However, the evaluation of candidate combinations of cells and scaffolds lacks a biomimetic in vitro model with broadly tunable, anisotropic and elastomeric structural-mechanical properties. Toward establishing such an in vitro model, in the current study, porcine aortic and pulmonary valvular interstitial cells (i.e. biomimetic cells) were cultivated on anisotropic, micromolded poly(glycerol sebacate) scaffolds (i.e. biomimetic scaffolds). Following 14 and 28 days of static culture, cell-seeded scaffolds and unseeded controls were assessed for their mechanical properties, and cell-seeded scaffolds were further characterized by confocal fluorescence and scanning electron microscopy, and by collagen and DNA assays. Poly(glycerol sebacate) micromolding yielded scaffolds with anisotropic stiffnesses resembling those of native valvular tissues in the low stress-strain ranges characteristic of physiologic valvular function. Scaffold anisotropy was largely retained upon cultivation with valvular interstitial cells; while the mechanical properties of unseeded scaffolds progressively diminished, cell-seeded scaffolds either retained or exceeded initial mechanical properties. Retention of mechanical properties in cell-seeded scaffolds paralleled the accretion of collagen, which increased significantly from 14 to 28 days. This study demonstrates that valvular interstitial cells can be cultivated on anisotropic poly(glycerol sebacate) scaffolds to yield biomimetic in vitro models with which clinically relevant cells and future scaffold designs can be evaluated.
Collapse
|
92
|
|
93
|
Mauri A, Zeisberger SM, Hoerstrup SP, Mazza E. Analysis of the Uniaxial and Multiaxial Mechanical Response of a Tissue-Engineered Vascular Graft. Tissue Eng Part A 2013; 19:583-92. [DOI: 10.1089/ten.tea.2012.0075] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Arabella Mauri
- Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Steffen M. Zeisberger
- Swiss Center for Regenerative Medicine (SCRM), University Hospital Zurich and University of Zurich, Zurich, Switzerland
- Department of Surgical Research and Clinic for Cardiovascular Surgery, University Hospital Zurich, Zurich, Switzerland
| | - Simon P. Hoerstrup
- Swiss Center for Regenerative Medicine (SCRM), University Hospital Zurich and University of Zurich, Zurich, Switzerland
- Department of Surgical Research and Clinic for Cardiovascular Surgery, University Hospital Zurich, Zurich, Switzerland
| | - Edoardo Mazza
- Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
- Swiss Federal Laboratories for Materials Science and Technology, EMPA, Duebendorf, Switzerland
| |
Collapse
|
94
|
Fan R, Bayoumi AS, Chen P, Hobson CM, Wagner WR, Mayer JE, Sacks MS. Optimal elastomeric scaffold leaflet shape for pulmonary heart valve leaflet replacement. J Biomech 2013; 46:662-9. [PMID: 23294966 DOI: 10.1016/j.jbiomech.2012.11.046] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2012] [Revised: 11/23/2012] [Accepted: 11/25/2012] [Indexed: 11/30/2022]
Abstract
Surgical replacement of the pulmonary valve (PV) is a common treatment option for congenital pulmonary valve defects. Engineered tissue approaches to develop novel PV replacements are intrinsically complex, and will require methodical approaches for their development. Single leaflet replacement utilizing an ovine model is an attractive approach in that candidate materials can be evaluated under valve level stresses in blood contact without the confounding effects of a particular valve design. In the present study an approach for optimal leaflet shape design based on finite element (FE) simulation of a mechanically anisotropic, elastomeric scaffold for PV replacement is presented. The scaffold was modeled as an orthotropic hyperelastic material using a generalized Fung-type constitutive model. The optimal shape of the fully loaded PV replacement leaflet was systematically determined by minimizing the difference between the deformed shape obtained from FE simulation and an ex-vivo microCT scan of a native ovine PV leaflet. Effects of material anisotropy, dimensional changes of PV root, and fiber orientation on the resulting leaflet deformation were investigated. In-situ validation demonstrated that the approach could guide the design of the leaflet shape for PV replacement surgery.
Collapse
Affiliation(s)
- Rong Fan
- Department of Biomedical Engineering and the Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX, United States
| | | | | | | | | | | | | |
Collapse
|
95
|
Huang HYS, Balhouse BN, Huang S. Application of simple biomechanical and biochemical tests to heart valve leaflets: implications for heart valve characterization and tissue engineering. Proc Inst Mech Eng H 2013. [PMID: 23185957 DOI: 10.1177/0954411912455004] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
A simple biomechanical test with real-time displacement and strain mapping is reported, which provides displacement vectors and principal strain directions during the mechanical characterization of heart valve tissues. The maps reported in the current study allow us to quickly identify the approximate strain imposed on a location in the samples. The biomechanical results show that the aortic valves exhibit stronger anisotropic mechanical behavior than that of the pulmonary valves before 18% strain equibiaxial stretching. In contrast, the pulmonary valves exhibit stronger anisotropic mechanical behavior than aortic valves beyond 28% strain equibiaxial stretching. Simple biochemical tests are also conducted. Collagens are extracted at different time points (24, 48, 72, and 120 h) at different locations in the samples. The results show that extraction time plays an important role in determining collagen concentration, in which a minimum of 72 h of extraction is required to obtain saturated collagen concentration. This work provides an easy approach for quantifying biomechanical and biochemical properties of semilunar heart valve tissues, and potentially facilitates the development of tissue engineered heart valves.
Collapse
Affiliation(s)
- Hsiao-Ying S Huang
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, USA.
| | | | | |
Collapse
|
96
|
Hoch E, Hirth T, Tovar GEM, Borchers K. Chemical tailoring of gelatin to adjust its chemical and physical properties for functional bioprinting. J Mater Chem B 2013; 1:5675-5685. [DOI: 10.1039/c3tb20745e] [Citation(s) in RCA: 155] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
97
|
Ciubotaru A, Cebotari S, Tudorache I, Beckmann E, Hilfiker A, Haverich A. Biological heart valves. ACTA ACUST UNITED AC 2013; 58:389-97. [DOI: 10.1515/bmt-2012-0148] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2012] [Accepted: 05/13/2013] [Indexed: 11/15/2022]
|
98
|
Steinhoff G, Strauer BE. Heart. Regen Med 2013. [DOI: 10.1007/978-94-007-5690-8_36] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
99
|
Alavi SH, Liu WF, Kheradvar A. Inflammatory Response Assessment of a Hybrid Tissue-Engineered Heart Valve Leaflet. Ann Biomed Eng 2012; 41:316-26. [DOI: 10.1007/s10439-012-0664-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2012] [Accepted: 09/22/2012] [Indexed: 12/25/2022]
|
100
|
Masoumi N, Jean A, Zugates JT, Johnson KL, Engelmayr GC. Laser microfabricated poly(glycerol sebacate) scaffolds for heart valve tissue engineering. J Biomed Mater Res A 2012; 101:104-14. [PMID: 22826211 DOI: 10.1002/jbm.a.34305] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2011] [Revised: 05/01/2012] [Accepted: 05/22/2012] [Indexed: 02/04/2023]
Abstract
Microfabricated poly(glycerol sebacate) (PGS) scaffolds may be applicable to tissue engineering heart valve leaflets by virtue of their controllable microstructure, stiffness, and elasticity. In this study, PGS scaffolds were computationally designed and microfabricated by laser ablation to match the anisotropy and peak tangent moduli of native bovine aortic heart valve leaflets. Finite element simulations predicted PGS curing conditions, scaffold pore shape, and strut width capable of matching the scaffold effective stiffnesses to the leaflet peak tangent moduli. On the basis of simulation predicted effective stiffnesses of 1.041 and 0.208 MPa for the scaffold preferred (PD) and orthogonal, cross-preferred (XD) material directions, scaffolds with diamond-shaped pores were microfabricated by laser ablation of PGS cured 12 h at 160°C. Effective stiffnesses measured for the scaffold PD (0.83 ± 0.13 MPa) and XD (0.21 ± 0.03 MPa) were similar to both predicted values and peak tangent moduli measured for bovine aortic valve leaflets in the circumferential (1.00 ± 0.16 MPa) and radial (0.26 ± 0.03 MPa) directions. Scaffolds cultivated with fibroblasts for 3 weeks accumulated collagen (736 ± 193 μg/g wet weight) and DNA (17 ± 4 μg/g wet weight). This study provides a basis for the computational design of biomimetic microfabricated PGS scaffolds for tissue-engineered heart valves.
Collapse
Affiliation(s)
- Nafiseh Masoumi
- Department of Bioengineering, The Pennsylvania State University, University Park, Pennsylvania 16802, USA
| | | | | | | | | |
Collapse
|