51
|
García C, Pérez F, Contreras C, Figueroa D, Barriga A, López-Rivera A, Araneda OF, Contreras HR. Saxitoxins and okadaic acid group: accumulation and distribution in invertebrate marine vectors from Southern Chile. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2015; 32:984-1002. [PMID: 25769036 DOI: 10.1080/19440049.2015.1028107] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Harmful algae blooms (HABs) are the main source of marine toxins in the aquatic environment surrounding the austral fjords in Chile. Huichas Island (Aysén) has an history of HABs spanning more than 30 years, but there is limited investigation of the bioaccumulation of marine toxins in the bivalves and gastropods from the Region of Aysén. In this study, bivalves (Mytilus chilenses, Choromytilus chorus, Aulacomya ater, Gari solida, Tagelus dombeii and Venus antiqua) and carnivorous gastropods (Argobuccinum ranelliformes and Concholepas concholepas) were collected from 28 sites. Researchers analysed the accumulation of STX-group toxins using a LC with a derivatisation post column (LC-PCOX), while lipophilic toxins (OA-group, azapiracids, pectenotoxins and yessotoxins) were analysed using LC-MS/MS with electrospray ionisation (+/-) in visceral (hepatopancreas) and non-visceral tissues (mantle, adductor muscle, gills and foot). Levels of STX-group and OA-group toxins varied among individuals from the same site. Among all tissue samples, the highest concentrations of STX-group toxins were noted in the hepatopancreas in V. antiqua (95 ± 0.1 μg STX-eq 100 g(-1)), T. dombeii (148 ± 1.4 μg STX-eq 100 g(-1)) and G. solida (3232 ± 5.2 μg STX-eq 100 g(-1); p < 0.05); in the adductor muscle in M. chilensis (2495 ± 6.4 μg STX-eq 100 g(-1); p < 0.05) and in the foot in C. concholepas (81 ± 0.7 μg STX-eq 100 g(-1)) and T. dombeii (114 ± 1.2 μg STX-eq 100 g(-1)). The highest variability of toxins was detected in G. solida, where high levels of carbamate derivatives were identified (GTXs, neoSTX and STX). In addition to the detected hydrophilic toxins, OA-group toxins were detected (OA and DTX-1) with an average ratio of ≈1:1. The highest levels of OA-group toxins were in the foot of C. concholepas, with levels of 400.3 ± 3.6 μg OA eq kg(-1) (p < 0.05) and with a toxic profile composed of 90% OA. A wide range of OA-group toxins was detected in M. chilensis with a toxicity < 80 μg OA eq kg(-1), but with 74% of those toxins detected in the adductor muscle. In all evaluated species, there was no detection of lipophilic toxins associated with biotransformation in molluscs and carnivorous gastropods. In addition, the STX-group and OA-group toxin concentrations in shellfish was not associated with the presence of HAB. The ranking of toxin concentration in the tissues of most species was: digestive glands > mantle > adductor muscle for the STX-group toxins and foot > digestive gland for the OA-group toxins. These results gave a better understanding of the variability and compartmentalisation of STX-group and OA-group toxins in different bivalve and gastropod species from the south of Chile, and the analyses determined that tissues could play an important role in the biotransformation of STX-group toxins and the retention of OA-group toxins.
Collapse
Affiliation(s)
- Carlos García
- a Marine Toxins Laboratory, Physiology and Biophysics Program, Institute of Biomedical Sciences, Faculty of Medicine , Universidad de Chile , Santiago , Chile
| | | | | | | | | | | | | | | |
Collapse
|
52
|
Leendert V, Van Langenhove H, Demeestere K. Trends in liquid chromatography coupled to high-resolution mass spectrometry for multi-residue analysis of organic micropollutants in aquatic environments. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.01.010] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
53
|
Rúbies A, Muñoz E, Gibert D, Cortés-Francisco N, Granados M, Caixach J, Centrich F. New method for the analysis of lipophilic marine biotoxins in fresh and canned bivalves by liquid chromatography coupled to high resolution mass spectrometry: A quick, easy, cheap, efficient, rugged, safe approach. J Chromatogr A 2015; 1386:62-73. [DOI: 10.1016/j.chroma.2015.01.088] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2014] [Revised: 01/27/2015] [Accepted: 01/30/2015] [Indexed: 12/01/2022]
|
54
|
Kokkotou K, Ioannou E, Nomikou M, Pitterl F, Vonaparti A, Siapi E, Zervou M, Roussis V. An integrated approach using UHPLC-PDA-HRMS and 2D HSQC NMR for the metabolic profiling of the red alga Laurencia: dereplication and tracing of natural products. PHYTOCHEMISTRY 2014; 108:208-219. [PMID: 25457502 DOI: 10.1016/j.phytochem.2014.10.007] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2014] [Revised: 10/04/2014] [Accepted: 10/08/2014] [Indexed: 06/04/2023]
Abstract
The global metabolic profile of Laurencia crude red algal extracts was addressed by applying high-throughput analytical techniques, namely UHPLC–PDA–HRMS and 2D HSQC NMR. An integrated platform including software tools and databases, such as Xcalibur, ToxID, ACD/Labs and MarinLit, has been developed to mine the complex analytical data towards the accelerated identification of known metabolites and the detection of new natural products at the early stages of phytochemical analysis. In parallel, a searchable ‘in-house’ Laurencia-focused NMR database incorporating chemical structures, NMR spectroscopic data and reported biological activities has been generated. The screening strategy has been developed as a tool to prioritize the crude extracts to be further subjected to phytochemical analysis by tracing the presence of new natural products among the pool of known compounds. The successful application of this integrated methodology in the crude extract of Laurencia chondrioides led to the rapid detection of two new C15 bromoallene acetogenins (1 and 2), which were subsequently isolated and characterized.
Collapse
|
55
|
McNamee SE, Elliott CT, Greer B, Lochhead M, Campbell K. Development of a planar waveguide microarray for the monitoring and early detection of five harmful algal toxins in water and cultures. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:13340-9. [PMID: 25361072 DOI: 10.1021/es504172j] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
A novel multiplex microarray has been developed for the detection of five groups of harmful algal and cyanobacterial toxins found in marine, brackish, and freshwater environments including domoic acid (DA), okadaic acid (OA, and analogues), saxitoxin (STX, and analogues), cylindrospermopsin (CYN) and microcystins (MC, and analogues). The sensitivity and specificity were determined and feasibility to be used as a screening tool investigated. Results for algal/cyanobacterial cultures (n = 12) and seawater samples (n = 33) were compared to conventional analytical methods, such as high performance liquid chromatography (HPLC) and liquid chromatography tandem mass spectrometry (LC-MS/MS). Detection limits for the 15 min assay were 0.37, 0.44, 0.05, 0.08, and 0.40 ng/mL for DA, OA, STX, CYN, and MC, respectively. The correlation of data obtained from the microarray compared to conventional analysis for the 12 cultures was r(2) = 0.83. Analysis of seawater samples showed that 82, 82, 70, 82, and 12% of samples were positive (>IC20) compared to 67, 55, 36, 0, and 0% for DA, OA, STX, CYN, and MC, respectively, for conventional analytical methods. The discrepancies in results can be attributed to the enhanced sensitivity and cross-reactivity profiles of the antibodies in the MBio microarray. The feasibility of the microarray as a rapid, easy to use, and highly sensitive screening tool has been illustrated for the five-plex detection of biotoxins. The research demonstrates an early warning screening assay to support national monitoring agencies by providing a faster and more accurate means of identifying and quantifying harmful toxins in water samples.
Collapse
Affiliation(s)
- Sara E McNamee
- Institute for Global Food Security, School of Biological Sciences, Queen's University , Stranmillis Road, Belfast BT9 5AG, United Kingdom
| | | | | | | | | |
Collapse
|
56
|
Li X, Li Z, Chen J, Shi Q, Zhang R, Wang S, Wang X. Detection, occurrence and monthly variations of typical lipophilic marine toxins associated with diarrhetic shellfish poisoning in the coastal seawater of Qingdao City, China. CHEMOSPHERE 2014; 111:560-567. [PMID: 24997966 DOI: 10.1016/j.chemosphere.2014.05.006] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2013] [Revised: 03/06/2014] [Accepted: 05/02/2014] [Indexed: 06/03/2023]
Abstract
In recent years, related research has mainly examined lipophilic marine toxins (LMTs) in contaminated bivalves or toxic algae, whereas the levels of LMTs in seawater remain largely unexplored. Okadaic acid (OA), yessotoxin (YTX), and pectenotoxin-2 (PTX2) are three typical LMTs produced by certain marine algae that are closely linked to diarrhetic shellfish poisoning. In this study, a new method of solid phase extraction combined with liquid chromatography - electrospray ionization ion trap tandem mass spectrometry was developed to determine the presence of OA, YTX, and PTX2 in seawater simultaneously. Satisfactory sensitivity, repeatability (RSD<25.00%) and recovery (56.25-70.18%) of the method were achieved. Then, the method was applied to determine the amounts of the three toxins in the coastal seawater. OA and PTX2 were detected in all the seawater samples collected from eight locations along the coastline of Qingdao City, China on October 23, 2012, with concentration ranges of OA 4.24-9.64ngL(-1) and PTX2 0.42-0.74ngL(-1). Monthly concentrations of OA and PTX2 in the seawater of four locations were determined over the course of a year, with concentration ranges of OA 1.41-89.52ngL(-1) and PTX2 below detectable limit to 1.70ngL(-1). The peak values of OA and PTX2 in coastal seawater were observed in August and July, respectively. Our results suggest that follow-up research on the fate modeling and risk assessment of LMTs in coastal seawater should be implemented.
Collapse
Affiliation(s)
- Xin Li
- Research Center for Marine Ecology, The First Institute of Oceanography, State Oceanic Administration, Qingdao 266061, China
| | - Zhaoyong Li
- Research Center for Marine Ecology, The First Institute of Oceanography, State Oceanic Administration, Qingdao 266061, China
| | - Junhui Chen
- Research Center for Marine Ecology, The First Institute of Oceanography, State Oceanic Administration, Qingdao 266061, China.
| | - Qian Shi
- Research Center for Marine Ecology, The First Institute of Oceanography, State Oceanic Administration, Qingdao 266061, China; College of Chemistry and Chemical Engineering, Ocean University of China, Qingdao 266100, China
| | - Rutan Zhang
- Research Center for Marine Ecology, The First Institute of Oceanography, State Oceanic Administration, Qingdao 266061, China
| | - Shuai Wang
- Research Center for Marine Ecology, The First Institute of Oceanography, State Oceanic Administration, Qingdao 266061, China; College of Chemistry and Chemical Engineering, Ocean University of China, Qingdao 266100, China
| | - Xiaoru Wang
- Research Center for Marine Ecology, The First Institute of Oceanography, State Oceanic Administration, Qingdao 266061, China; College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| |
Collapse
|
57
|
García-Altares M, Casanova A, Bane V, Diogène J, Furey A, de la Iglesia P. Confirmation of pinnatoxins and spirolides in shellfish and passive samplers from Catalonia (Spain) by liquid chromatography coupled with triple quadrupole and high-resolution hybrid tandem mass spectrometry. Mar Drugs 2014; 12:3706-32. [PMID: 24960460 PMCID: PMC4071598 DOI: 10.3390/md12063706] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2014] [Revised: 05/13/2014] [Accepted: 05/19/2014] [Indexed: 12/04/2022] Open
Abstract
Cyclic imines are lipophilic marine toxins that bioaccumulate in seafood. Their structure comprises a cyclic-imino moiety, responsible for acute neurotoxicity in mice. Cyclic imines have not been linked yet to human poisonings and are not regulated in Europe, although the European Food Safety Authority requires more data to perform a conclusive risk assessment for consumers. This work presents the first detection of pinnatoxin G (PnTX-G) in Spain and 13-desmethyl spirolide C (SPX-1) in shellfish from Catalonia (Spain, NW Mediterranean Sea). Cyclic imines were found at low concentrations (2 to 60 µg/kg) in 13 samples of mussels and oysters (22 samples analyzed). Pinnatoxin G has been also detected in 17 seawater samples (out of 34) using solid phase adsorption toxin tracking devices (0.3 to 0.9 µg/kg-resin). Pinnatoxin G and SPX-1 were confirmed with both low and high resolution (<2 ppm) mass spectrometry by comparison of the response with that from reference standards. For other analogs without reference standards, we applied a strategy combining low resolution MS with a triple quadrupole mass analyzer for a fast and reliable screening, and high resolution MS LTQ Orbitrap® for unambiguous confirmation. The advantages and limitations of using high resolution MS without reference standards were discussed.
Collapse
Affiliation(s)
- María García-Altares
- Institute of Agrifood Research and Technology (IRTA), Poble Nou Road, km. 5.5, Sant Carles de la Ràpita 43540, Spain.
| | - Alexis Casanova
- Institute of Agrifood Research and Technology (IRTA), Poble Nou Road, km. 5.5, Sant Carles de la Ràpita 43540, Spain.
| | - Vaishali Bane
- Mass Spectrometry Research Centre (MSRC) and PROTEOBIO Research Group, Department of Chemistry, Cork Institute of Technology, Bishopstown, Cork, Ireland.
| | - Jorge Diogène
- Institute of Agrifood Research and Technology (IRTA), Poble Nou Road, km. 5.5, Sant Carles de la Ràpita 43540, Spain.
| | - Ambrose Furey
- Mass Spectrometry Research Centre (MSRC) and PROTEOBIO Research Group, Department of Chemistry, Cork Institute of Technology, Bishopstown, Cork, Ireland.
| | - Pablo de la Iglesia
- Institute of Agrifood Research and Technology (IRTA), Poble Nou Road, km. 5.5, Sant Carles de la Ràpita 43540, Spain.
| |
Collapse
|
58
|
Orellana G, Vanden Bussche J, Van Meulebroek L, Vandegehuchte M, Janssen C, Vanhaecke L. Validation of a confirmatory method for lipophilic marine toxins in shellfish using UHPLC-HR-Orbitrap MS. Anal Bioanal Chem 2014; 406:5303-12. [PMID: 24939136 DOI: 10.1007/s00216-014-7958-6] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2014] [Revised: 05/15/2014] [Accepted: 06/06/2014] [Indexed: 11/25/2022]
Abstract
Lipophilic marine toxins are produced by harmful microalgae and can accumulate in edible filter feeders such as shellfish, leading to an introduction of toxins into the human food chain, causing different poisoning effects. During the last years, analytical methods, based on liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), have been consolidated by interlaboratory validations. However, the main drawback of LC-MS/MS methods remains the limited number of compounds that can be analyzed in a single run. Due to the targeted nature of these methods, only known toxins, previously considered during method optimization, will be detected. Therefore in this study, a method based on ultra-high-performance liquid chromatography coupled to high-resolution Orbitrap mass spectrometry (UHPLC-HR-Orbitrap MS) was developed. Its quantitative performance was evaluated for confirmatory analysis of regulated lipophilic marine toxins in shellfish flesh according to Commission Decision 2002/657/EC. Okadaic acid (OA), dinophysistoxin-1 (DTX-1), pectenotoxin-2 (PTX-2), azaspiracid-1 (AZA-1), yessotoxin (YTX), and 13-desmethyl spirolide C (SPX-1) were quantified using matrix-matched calibration curves (MMS). For all compounds, the reproducibility ranged from 2.9 to 4.9 %, repeatability from 2.9 to 4.9 %, and recoveries from 82.9 to 113 % at the three different spiked levels. In addition, confirmatory identification of the compounds was effectively performed by the presence of a second diagnostic ion ((13)C). In conclusion, UHPLC-HR-Orbitrap MS permitted more accurate and faster detection of the target toxins than previously described LC-MS/MS methods. Furthermore, HRMS allows to retrospectively screen for many analogues and metabolites using its full-scan capabilities but also untargeted screening through the use of metabolomics software.
Collapse
Affiliation(s)
- Gabriel Orellana
- Faculty of Veterinary Medicine, Department of Veterinary Public Health and Food Safety, Laboratory of Chemical Analysis, Ghent University, Salisburylaan 133, 9820, Merelbeke, Belgium
| | | | | | | | | | | |
Collapse
|
59
|
Fang L, Yao X, Wang L, Li J. Solid-Phase Extraction-Based Ultra-Sensitive Detection of Four Lipophilic Marine Biotoxins in Bivalves by High-Performance Liquid Chromatography-Tandem Mass Spectrometry. J Chromatogr Sci 2014; 53:373-9. [DOI: 10.1093/chromsci/bmu054] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
60
|
Determination of lipophilic marine toxins in mussels. Quantification and confirmation criteria using high resolution mass spectrometry. J Chromatogr A 2013; 1328:16-25. [PMID: 24444801 DOI: 10.1016/j.chroma.2013.12.071] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2013] [Revised: 12/19/2013] [Accepted: 12/23/2013] [Indexed: 11/22/2022]
Abstract
A multitoxin method has been developed for quantification and confirmation of lipophilic marine biotoxins in mussels by liquid chromatography coupled to high resolution mass spectrometry (HRMS), using an Orbitrap-Exactive HCD mass spectrometer. Okadaic acid (OA), yessotoxin, azaspiracid-1, gymnodimine, 13-desmethyl spirolide C, pectenotoxin-2 and Brevetoxin B were analyzed as representative compounds of each lipophilic toxin group. HRMS identification and confirmation criteria were established. Fragment and isotope ions and ion ratios were studied and evaluated for confirmation purpose. In depth characterization of full scan and fragmentation spectrum of the main toxins were carried out. Accuracy (trueness and precision), linearity, calibration curve check, limit of quantification (LOQ) and specificity were the parameters established for the method validation. The validation was performed at 0.5 times the current European Union permitted levels. The method performed very well for the parameters investigated. The trueness, expressed as recovery, ranged from 80% to 94%, the precision, expressed as intralaboratory reproducibility, ranged from 5% to 22% and the LOQs range from 0.9 to 4.8pg on column. Uncertainty of the method was also estimated for OA, using a certified reference material. A top-down approach considering two main contributions: those arising from the trueness studies and those coming from the precision's determination, was used. An overall expanded uncertainty of 38% was obtained.
Collapse
|
61
|
Castro-Puyana M, Herrero M. Metabolomics approaches based on mass spectrometry for food safety, quality and traceability. Trends Analyt Chem 2013. [DOI: 10.1016/j.trac.2013.05.016] [Citation(s) in RCA: 70] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
62
|
McNamee SE, Elliott CT, Delahaut P, Campbell K. Multiplex biotoxin surface plasmon resonance method for marine biotoxins in algal and seawater samples. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2013; 20:6794-807. [PMID: 23250726 DOI: 10.1007/s11356-012-1329-7] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2012] [Accepted: 11/12/2012] [Indexed: 05/15/2023]
Abstract
A multiplex surface plasmon resonance (SPR) biosensor method for the detection of paralytic shellfish poisoning (PSP) toxins, okadaic acid (and analogues) and domoic acid was developed. This method was compared to enzyme-linked immunosorbent assay (ELISA) methods. Seawater samples (n=256) from around Europe were collected by the consortia of an EU project MIcroarrays for the Detection of Toxic Algae (MIDTAL) and evaluated using each method. A simple sample preparation procedure was developed which involved lysing and releasing the toxins from the algal cells with glass beads followed by centrifugation and filtering the extract before testing for marine biotoxins by both multi-SPR and ELISA. Method detection limits based on IC20 values for PSP, okadaic acid and domoic acid toxins were 0.82, 0.36 and 1.66 ng/ml, respectively, for the prototype multiplex SPR biosensor. Evaluation by SPR for seawater samples has shown that 47, 59 and 61 % of total seawater samples tested positive (result greater than the IC20) for PSP, okadaic acid (and analogues) and domoic acid toxins, respectively. Toxic samples were received mainly from Spain and Ireland. This work has demonstrated the potential of multiplex analysis for marine biotoxins in algal and seawater samples with results available for 24 samples within a 7 h period for three groups of key marine biotoxins. Multiplex immunological methods could therefore be used as early warning monitoring tools for a variety of marine biotoxins in seawater samples.
Collapse
Affiliation(s)
- Sara E McNamee
- Institute for Global Food Security, School of Biological Sciences, Queen's University, Stranmillis Road, Belfast, BT9 5AG, UK,
| | | | | | | |
Collapse
|
63
|
Zamorano R, Marín M, Cabrera F, Figueroa D, Contreras C, Barriga A, Lagos N, García C. Determination of the variability of both hydrophilic and lipophilic toxins in endemic wild bivalves and carnivorous gastropods from the Southern part of Chile. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2013; 30:1660-77. [DOI: 10.1080/19440049.2013.805438] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
64
|
Prego-Faraldo MV, Valdiglesias V, Méndez J, Eirín-López JM. Okadaic acid meet and greet: an insight into detection methods, response strategies and genotoxic effects in marine invertebrates. Mar Drugs 2013; 11:2829-45. [PMID: 23939476 PMCID: PMC3766868 DOI: 10.3390/md11082829] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2013] [Revised: 07/30/2013] [Accepted: 08/01/2013] [Indexed: 12/24/2022] Open
Abstract
Harmful Algal Blooms (HABs) constitute one of the most important sources of contamination in the oceans, producing high concentrations of potentially harmful biotoxins that are accumulated across the food chains. One such biotoxin, Okadaic Acid (OA), is produced by marine dinoflagellates and subsequently accumulated within the tissues of filtering marine organisms feeding on HABs, rapidly spreading to their predators in the food chain and eventually reaching human consumers causing Diarrhetic Shellfish Poisoning (DSP) syndrome. While numerous studies have thoroughly evaluated the effects of OA in mammals, the attention drawn to marine organisms in this regard has been scarce, even though they constitute primary targets for this biotoxin. With this in mind, the present work aimed to provide a timely and comprehensive insight into the current literature on the effect of OA in marine invertebrates, along with the strategies developed by these organisms to respond to its toxic effect together with the most important methods and techniques used for OA detection and evaluation.
Collapse
Affiliation(s)
- María Verónica Prego-Faraldo
- XENOMAR Group, Department of Cellular and Molecular Biology, University of A Coruna, E15071 A Coruña, Spain; E-Mails: (M.V.P.-F.); (J.M.)
| | - Vanessa Valdiglesias
- Toxicology Unit, Department of Psychobiology, University of A Coruña, E15071 A Coruña, Spain; E-Mail:
| | - Josefina Méndez
- XENOMAR Group, Department of Cellular and Molecular Biology, University of A Coruna, E15071 A Coruña, Spain; E-Mails: (M.V.P.-F.); (J.M.)
| | - José M. Eirín-López
- XENOMAR Group, Department of Cellular and Molecular Biology, University of A Coruna, E15071 A Coruña, Spain; E-Mails: (M.V.P.-F.); (J.M.)
- Chromatin Structure and Evolution (CHROMEVOL) Group, Department of Biological Sciences, Florida International University, North Miami, FL 33181, USA
- Author to whom correspondence should be addressed; E-Mail: ; Tel.: +34-981-167-000; Fax: +34-981-167-065
| |
Collapse
|
65
|
Rapid Screening and Identification of Paralytic Shellfish Poisoning Toxins in Red Tide Algae Using Hydrophilic Interaction Liquid Chromatography-High Resolution Mass Spectrometry with an Accurate-Mass Database. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2013. [DOI: 10.1016/s1872-2040(13)60739-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
66
|
Coupling ultra high-pressure liquid chromatography with mass spectrometry: Constraints and possible applications. J Chromatogr A 2013; 1292:2-18. [PMID: 23062879 DOI: 10.1016/j.chroma.2012.09.061] [Citation(s) in RCA: 105] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2012] [Revised: 09/19/2012] [Accepted: 09/20/2012] [Indexed: 01/10/2023]
|
67
|
Liu Q, Zhou B, Wang X, Ke Y, Jin Y, Yin L, Liang X. Establishment of a search library about benzylisoquinoline alkaloids based on selective separation on the binaphthyl column and standard analysis on C18 column. J Sep Sci 2012; 35:3317-25. [DOI: 10.1002/jssc.201200605] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2012] [Revised: 08/07/2012] [Accepted: 08/12/2012] [Indexed: 01/04/2023]
Affiliation(s)
- Qiaoxia Liu
- Engineering Research Center of Pharmaceutical Process Chemistry; Ministry of Education; School of Pharmacy; East China University of Science and Technology; Shanghai China
| | - Binbin Zhou
- Engineering Research Center of Pharmaceutical Process Chemistry; Ministry of Education; School of Pharmacy; East China University of Science and Technology; Shanghai China
| | - Xinliang Wang
- Engineering Research Center of Pharmaceutical Process Chemistry; Ministry of Education; School of Pharmacy; East China University of Science and Technology; Shanghai China
| | - Yanxiong Ke
- Engineering Research Center of Pharmaceutical Process Chemistry; Ministry of Education; School of Pharmacy; East China University of Science and Technology; Shanghai China
| | - Yu Jin
- Engineering Research Center of Pharmaceutical Process Chemistry; Ministry of Education; School of Pharmacy; East China University of Science and Technology; Shanghai China
| | - Lihui Yin
- National Institutes for Food and Drug Control (NIFDC); Beijing China
| | - Xinmiao Liang
- Engineering Research Center of Pharmaceutical Process Chemistry; Ministry of Education; School of Pharmacy; East China University of Science and Technology; Shanghai China
| |
Collapse
|
68
|
Carey B, Fidalgo Sáez MJ, Hamilton B, O'Halloran J, van Pelt FNAM, James KJ. Elucidation of the mass fragmentation pathways of the polyether marine toxins, dinophysistoxins, and identification of isomer discrimination processes. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2012; 26:1793-1802. [PMID: 22777781 DOI: 10.1002/rcm.6278] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
RATIONALE Most of the liquid chromatography/mass spectrometry (LC/MS) methods that have been developed for the analysis of Diarrhetic Shellfish Poisoning (DSP) toxins in shellfish and algae samples have been unable to differentiate the isomers okadaic acid (OA) and dinophysistoxin-2 (DTX2), unless separated by chromatography. Since there are many bioconversion products of these compounds it is imperative to determine characteristic product ions, which can provide unequivocal identification of OA and DTX2 and their analogs. METHODS Using electrospray ionization, the fragmentation processes for two types of precursor ions, [M+Na](+) and [M-H](-), of the polyether marine toxins, dinophysistoxins (DTXs), were studied using a hybrid linear ion trap Orbitrap mass spectrometer which provided high mass accuracy data in combination with multiple tandem mass (MS(n)) spectra. Three structurally related toxins were compared; okadaic acid (OA), dinophysistoxin-2 (DTX2) and dinophysistoxin-1 (DTX1). A quick multiple reaction monitoring (MRM) LC/MS/MS method was developed utilizing the characteristic precursor/product ion mass transitions. RESULTS Comparison of the high-resolution product ion, [M-H](-), spectra of these toxins featured dominant signals that resulted from two six-centered rearrangements and previously proposed fragmentation pathways for the ion of m/z 321 and 293 have been corrected and identified. By contrast, the [M+Na](+) product ion spectra only revealed distinctive ions for the isomers, OA (m/z 595, 443 and 151) and DTX2 (m/z 581, 429 and 165). To illustrate the benefits of this study, a mass selective LC/MS/MS method was developed in which the isomers OA and DTX2 co-eluted but were distinguished using the mass transitions, m/z 827/595, 827/443 (OA) and m/z 827/581, 827/429 (DTX2). CONCLUSIONS Comparison of OA, DTX2 and DTX1 led to the correction of proposed negative ion mode fragmentation pathways. Through extensive study and comparison of the [M+Na](+) product ion spectra, distinctive product ions were identified which allowed for these compounds to be identified and distinguished without separation for the first time.
Collapse
Affiliation(s)
- Bébhine Carey
- Environmental Research Institute, University College Cork, Lee Road, Cork, Ireland
| | | | | | | | | | | |
Collapse
|
69
|
Mol HGJ, Zomer P, de Koning M. Qualitative aspects and validation of a screening method for pesticides in vegetables and fruits based on liquid chromatography coupled to full scan high resolution (Orbitrap) mass spectrometry. Anal Bioanal Chem 2012; 403:2891-908. [PMID: 22664752 PMCID: PMC3380251 DOI: 10.1007/s00216-012-6100-x] [Citation(s) in RCA: 86] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2012] [Revised: 04/30/2012] [Accepted: 05/03/2012] [Indexed: 10/31/2022]
Abstract
The analytical capabilities of liquid chromatography with single-stage high-resolution mass spectrometry have been investigated with emphasis on qualitative aspects related to selective detection during screening and to identification. The study involved 21 different vegetable and fruit commodities, a screening database of 556 pesticides for evaluation of false positives, and a test set of 130 pesticides spiked to the commodities at 0.01, 0.05, and 0.20 mg/kg for evaluation of false negatives. The final method involved a QuEChERS-based sample preparation (without dSPE clean up) and full scan acquisition using alternating scan events without/with fragmentation, at a resolving power of 50,000. Analyte detection was based on extraction of the exact mass (±5 ppm) of the major adduct ion at the database retention time ±30 s and the presence of a second diagnostic ion. Various options for the additional ion were investigated and compared (other adduct ions, M + 1 or M + 2 isotopes, fragments). The two-ion approach for selective detection of the pesticides in the full scan data was compared with two alternative approaches based on response thresholds. Using the two-ion approach, the number of false positives out of 11,676 pesticide/commodity combinations targeted was 36 (0.3 %). The percentage of false negatives, assessed for 2,730 pesticide/commodity combinations, was 13 %, 3 %, and 1 % at the 0.01-, 0.05-, and 0.20-mg/kg level, respectively (slightly higher with fully automated detection). Following the SANCO/12495/2011 protocol for validation of screening methods, the screening detection limit was determined for 130 pesticides and found to be 0.01, 0.05, and ≥0.20 mg/kg for 86, 30, and 14 pesticides, respectively. For the detected pesticides in the spiked samples, the ability for unambiguous identification according to EU criteria was evaluated. A proposal for adaption of the criteria was made.
Collapse
Affiliation(s)
- Hans G J Mol
- RIKILT Institute of Food Safety, Wageningen University and Research Centre, The Netherlands.
| | | | | |
Collapse
|
70
|
Garcia C, Rodriguez-Unda N, Contreras C, Barriga A, Lagos N. Lipophilic toxin profiles detected in farmed and benthic mussels populations from the most relevant production zones in Southern Chile. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2012; 29:1011-20. [DOI: 10.1080/19440049.2012.662704] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Affiliation(s)
- Carlos Garcia
- a Laboratorio Bioquímica de Membrana , Programa de Fisiología y Biofísica, Facultad de Medicina, Universidad de Chile , Santiago , Chile
| | - Nelson Rodriguez-Unda
- a Laboratorio Bioquímica de Membrana , Programa de Fisiología y Biofísica, Facultad de Medicina, Universidad de Chile , Santiago , Chile
| | - Cristóbal Contreras
- a Laboratorio Bioquímica de Membrana , Programa de Fisiología y Biofísica, Facultad de Medicina, Universidad de Chile , Santiago , Chile
| | - Andrés Barriga
- b CEPEDEQ , Facultad de Ciencias Químicas y Farmaceúticas, Universidad de Chile , Santiago , Chile
| | - Néstor Lagos
- a Laboratorio Bioquímica de Membrana , Programa de Fisiología y Biofísica, Facultad de Medicina, Universidad de Chile , Santiago , Chile
| |
Collapse
|
71
|
Hurtaud-Pessel D, Jagadeshwar-Reddy T, Verdon E. Development of a new screening method for the detection of antibiotic residues in muscle tissues using liquid chromatography and high resolution mass spectrometry with a LC-LTQ-Orbitrap instrument. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2012; 28:1340-51. [PMID: 22007888 DOI: 10.1080/19440049.2011.605772] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
A liquid chromatography-high resolution mass spectrometry (LC-HRMS) method was developed for screening meat for a wide range of antibiotics used in veterinary medicine. Full-scan mode under high resolution mass spectral conditions using an LTQ-Orbitrap mass spectrometer with resolving power 60,000 full width at half maximum (FWHM) was applied for analysis of the samples. Samples were prepared using two extraction protocols prior to LC-HRMS analysis. The scope of the method focuses on screening the following main families of antibacterial veterinary drugs: penicillins, cephalosporins, sulfonamides, macrolides, tetracyclines, aminoglucosides and quinolones. Compounds were successfully identified in spiked samples from their accurate mass and LC retention times from the acquired full-scan chromatogram. Automated data processing using ToxId software allowed rapid treatment of the data. Analyses of muscle tissues from real samples collected from antibiotic-treated animals was carried out using the above methodology and antibiotic residues were identified unambiguously. Further analysis of the data for real samples allowed the identification of the targeted antibiotic residues but also non-targeted compounds, such as some of their metabolites.
Collapse
Affiliation(s)
- D Hurtaud-Pessel
- ANSES, French Agency for Food, Environmental and Occupational Health Safety, Laboratory of Fougeres, Javené, Fougères, France.
| | | | | |
Collapse
|
72
|
Milman BL, Zhurkovich IK. Towards a full reference library of MS(n) spectra. II: A perspective from the library of pesticide spectra extracted from the literature/Internet. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2011; 25:3697-3705. [PMID: 22468332 DOI: 10.1002/rcm.5279] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
To gain perspective on building full transferable libraries of MS(n) spectra from their diverse/numerous collections, a new library was built from 1723 MS(>1) spectra (mainly MS² spectra) of 490 pesticides and related compounds. Spectra acquired on different types of tandem instruments in various experimental conditions were extracted from 168 literature articles and Internet sites. Testing of the library was based on searches where 'unknown' and reference spectra originated from different sources (mainly from different laboratories) were cross-compared. The NIST 05 MS² library was added to the reference spectra. The library searches were performed with all the test spectra or were divided into different subsamples containing (a) various numbers of replicate spectra of test compounds or (b) spectra acquired from different instrument types. Thus, the dependence of true/false search (identification) result rates on different factors was explored. The percentage of 1st rank correct identifications (true positives) for the only 'unknown' mass spectrum and two and more reference spectra and matching precursor ion m/z values was 89%. For qualified matches, above the cut-off match factor, that rate decreased to 80%. The corresponding rates based on the best match for two and more 'unknown' and reference spectral replicates were 89-94%. For quadrupole instruments, the rates were even higher: 91-95% (one 'unknown' spectrum) and 90-100% (two and more such spectra). This study shows that MS² spectral libraries generated from the numerous literature/Internet sources are not less efficient for the goal of identification of unknown compounds including pesticides than very common EI-MS¹ libraries and are almost as efficient as the most productive from current MS² spectral databases. Such libraries may be used as individual reference databases or supplements to large experimental spectral collections covering many groups of abundant compounds and different types of tandem mass spectrometers.
Collapse
Affiliation(s)
- Boris L Milman
- D.I. Mendeleyev Institute for Metrology, Saint Petersburg, Russia.
| | | |
Collapse
|
73
|
Kaufmann A. The current role of high-resolution mass spectrometry in food analysis. Anal Bioanal Chem 2011; 403:1233-49. [PMID: 22179491 DOI: 10.1007/s00216-011-5629-4] [Citation(s) in RCA: 151] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2011] [Revised: 11/28/2011] [Accepted: 11/29/2011] [Indexed: 11/26/2022]
Abstract
High-resolution mass spectrometry (HRMS), which is used for residue analysis in food, has gained wider acceptance in the last few years. This development is due to the availability of more rugged, sensitive, and selective instrumentation. The benefits provided by HRMS over classical unit-mass-resolution tandem mass spectrometry are considerable. These benefits include the collection of full-scan spectra, which provides greater insight into the composition of a sample. Consequently, the analyst has the freedom to measure compounds without previous compound-specific tuning, the possibility of retrospective data analysis, and the capability of performing structural elucidations of unknown or suspected compounds. HRMS strongly competes with classical tandem mass spectrometry in the field of quantitative multiresidue methods (e.g., pesticides and veterinary drugs). It is one of the most promising tools when moving towards nontargeted approaches. Certain hardware and software issues still have to be addressed by the instrument manufacturers for it to dislodge tandem mass spectrometry from its position as the standard trace analysis tool.
Collapse
|
74
|
Zhang JL, Kubanek J, Hay ME, Aalbersberg W, Ye WC, Jiang RW. Rapid identification of triterpenoid sulfates and hydroxy fatty acids including two new constituents from Tydemania expeditionis by liquid chromatography-mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2011; 46:908-16. [PMID: 21915955 PMCID: PMC3205076 DOI: 10.1002/jms.1969] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Tydemania expeditionis Weber-van Bosse (Udoteaceae) is a weakly calcified green alga. In the present paper, liquid chromatography coupled with photodiode array detection and electrospray mass spectrometry was developed to identify the fingerprint components. A total of four triterpenoid sulfates and three hydroxy fatty acids in the ethyl acetate fraction of the crude extract were structurally characterized on the basis of retention time, online UV spectrum, and mass fragmentation pattern. Furthermore, a detailed liquid chromatography-mass spectrometry analysis revealed two new hydroxy fatty acids, which were then prepared and characterized by extensive nuclear magnetic resonance (NMR) analyses. The proposed method provides a scientific and technical platform for the rapid identification of triterpenoid sulfates and hydroxy fatty acids in similar marine algae and terrestrial plants.
Collapse
Affiliation(s)
- Jian-Long Zhang
- Guangdong Province Key Laboratory of Pharmacodynamic Constituents of Traditional Chinese Medicine and New Drugs Research, College of Pharmacy, Jinan University, Guangzhou, China
| | - Julia Kubanek
- School of Biology and School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332
| | - Mark E. Hay
- School of Biology and School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332
| | | | - Wen-Cai Ye
- Guangdong Province Key Laboratory of Pharmacodynamic Constituents of Traditional Chinese Medicine and New Drugs Research, College of Pharmacy, Jinan University, Guangzhou, China
| | - Ren-Wang Jiang
- Guangdong Province Key Laboratory of Pharmacodynamic Constituents of Traditional Chinese Medicine and New Drugs Research, College of Pharmacy, Jinan University, Guangzhou, China
- Corresponding authors: Ren-Wang Jiang: (8620) 85221016, Fax: (8620) 85221559,
| |
Collapse
|
75
|
Otero P, Alfonso A, Alfonso C, Rodríguez P, Vieytes MR, Botana LM. Effect of uncontrolled factors in a validated liquid chromatography-tandem mass spectrometry method question its use as a reference method for marine toxins: major causes for concern. Anal Chem 2011; 83:5903-11. [PMID: 21651235 DOI: 10.1021/ac200732m] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Chromatographic techniques coupled to mass spectrometry is the method of choice to replace the mouse bioassay (MBA) to detect marine toxins. This paper evaluates the influence of different parameters such as toxin solvents, mass spectrometric detection method, mobile-phase-solvent brands and equipment on okadaic acid (OA), dinophysistoxin-1 (DTX-1), and dinophysistoxin-2 (DTX-2) quantification. In addition, the study compares the results obtained when a toxin is quantified against its own calibration curve and with the calibration curve of the other analogues. The experiments were performed by liquid chromatography (LC) and ultraperformance liquid chromatography (UPLC) with tandem mass spectrometry detection (MS/MS). Three acetonitrile brands and two toxin solvents were employed, and three mass spectrometry detection methods were checked. One method that contains the transitions for azaspiracid-1 (AZA-1), azaspiracid-2 (AZA-2), azaspiracid-3(AZA-3), gimnodimine (GYM), 13-desmethyl spirolide C (SPX-1), pectenotoxin-2 (PTX-2), OA, DTX-1, DTX-2, yessotoxin (YTX), homoYTX, and 45-OH-YTX was compared in both instruments. This method operated in simultaneous positive and negative ionization mode. The other two mass methods operated only in negative ionization mode, one contains transitions to detect DTX-1, OA DTX-2, YTX, homoYTX, and 45-OH-YTX and the other only the transitions for the toxins under study OA, DTX-1, and DTX-2. With dependence on the equipment and mobile phase used, the amount of toxin quantified can be overestimated or underestimated, up to 44% for OA, 46% for DTX-1, and 48% for DTX-2. In addition, when a toxin was quantified using the calibration curve of the other analogues, the toxin amount obtained is different. The maximum variability was obtained when DTX-2 was quantified using either OA or a DTX-1 calibration curve. In this case, the overestimation was up to 88% using the OA calibration curve and up to 204% using the DTX-1 calibration curve. In summary, the correct quantification of DSP toxins by MS detection depends on multiple factors. Since these factors are not taken into account in a validated protocol, these results question the convenience of having MS/MS as a reference method for protecting consumers of marine toxins, moreover if toxicity of each group is considered independently and total toxicity is not summed anymore as it is in the MBA.
Collapse
Affiliation(s)
- Paz Otero
- Departamento de Farmacología, Facultad de Veterinaria, Universidad de Santiago de Compostela, Lugo, Spain
| | | | | | | | | | | |
Collapse
|