51
|
Chinnadayyala SR, Cho S. Porous Platinum Black-Coated Minimally Invasive Microneedles for Non-Enzymatic Continuous Glucose Monitoring in Interstitial Fluid. NANOMATERIALS 2020; 11:nano11010037. [PMID: 33375593 PMCID: PMC7824010 DOI: 10.3390/nano11010037] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 12/20/2020] [Accepted: 12/21/2020] [Indexed: 01/03/2023]
Abstract
Individuals with diabetes can benefit considerably from continuous blood glucose monitoring. To address this challenge, a proof-of-concept was performed for continuous glucose monitoring (CGM) based on an enzymeless porous nanomaterial (pNM)-modified microneedle electrode array (MNEA). The pNM sensing layer was electrochemically deposited on MNs by applying a fixed negative current of -2.5 mA cm-2 for 400 s. The pNM-modified MNEA was packed using a biocompatible Nafion ionomer. The fabricated MNEAs were 600 × 100 × 150 µm in height, width, and thickness, respectively. The surfaces of the modified MNs were characterized by scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). The fabricated MNEAs showed a wide dynamic range (1-30 mM) in phosphate-buffered saline (PBS) and in artificial interstitial fluid (ISF), with good sensitivities (PBS: 1.792 ± 0.25 µA mM-1 cm-2, ISF: 0.957 ± 0.14 µA mM-1 cm-2) and low detection limits (PBS: 7.2 µM, ISF: 22 µM). The sensor also showed high stability (loss of 3.5% at the end of 16 days), selectivity, and reproducibility (Relative standard deviations (RSD) of 1.64% and 0.70% for intra- and inter-assay, respectively) and a good response time (2 s) with great glucose recovery rates in ISF (98.7-102%).
Collapse
Affiliation(s)
- Somasekhar R. Chinnadayyala
- Department of Electronic Engineering, Gachon University, 1342 Seongnamdaero, Seongnam-si, Gyeonggi-do 13120, Korea;
| | - Sungbo Cho
- Department of Electronic Engineering, Gachon University, 1342 Seongnamdaero, Seongnam-si, Gyeonggi-do 13120, Korea;
- Department of Health Science and Technology, GAIHST, Gachon University, Incheon 21999, Korea
- Correspondence: ; Tel.: +82-(31)-750-5321
| |
Collapse
|
52
|
Xiao W, Zhi D, Pan Q, Liang Y, Zhou F, Chen Z. A ratiometric bilirubin sensor based on a fluorescent gold nanocluster film with dual emissions. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:5691-5698. [PMID: 33205788 DOI: 10.1039/d0ay01781g] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Bilirubin originates from hemoglobin metabolism and is an important biomarker for liver function. A ratiometric film sensor based on gold nanoclusters (AuNCs) was fabricated for highly sensitive determination of free bilirubin (fBR). Using bovine serum albumin (BSA) as a template, AuNCs that can emit blue and red fluorescence were prepared by the hydrothermal method at different pH values. Two kinds of AuNCs were incorporated into a single film by the layer-by-layer assembly (LBL) technique. The obtained thin-film showed dual fluorescence peaks excited at 372 nm, corresponding to the blue (443 nm) and red (622 nm) emissions of AuNCs respectively. When fBR interacted with the film, both fluorescence peaks were quenched at different degrees. A ratiometric method for fBR detection was established based on the fluorescence intensity ratio of the two emissions. The linear calibration curve for fBR lay in the concentration range of 0.01-2.00 μmol L-1 with a detection limit of 8.90 ± 0.34 nmol L-1 (S/N = 3). The film sensor showed a quick and sensitive response to fBR and could detect fBR in real samples with satisfactory results.
Collapse
Affiliation(s)
- Wenxiang Xiao
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China.
| | | | | | | | | | | |
Collapse
|
53
|
Designing of a stable and selective glucose biosensor by glucose oxidase immobilization on glassy carbon electrode sensitive to H2O2 via nanofiber interface. J APPL ELECTROCHEM 2020. [DOI: 10.1007/s10800-020-01502-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
54
|
Assaifan AK, Al Habis N, Ahmad I, Alshehri NA, Alharbi HF. Scaling-up medical technologies using flexographic printing. Talanta 2020; 219:121236. [PMID: 32887127 DOI: 10.1016/j.talanta.2020.121236] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Revised: 05/31/2020] [Accepted: 05/31/2020] [Indexed: 11/17/2022]
Abstract
Medical technologies, such as point-of-care devices and biological and chemical assays which rely on functional materials deposited on top of substrates, are in great demand due to an increase in the prevalence of diseases worldwide. A significant number of these medical technologies are still in their infancy with respect to commercialization because of the high cost, material and complexity of the conventionally available fabrication techniques. As a result, medical technologies, in broad terms, require low cost and mass production fabrication methods in order to overcome the commercialization challenges. Recently, researchers have explored the flexographic printing technique which is widely employed for food packaging and newspaper production. This technique has proved cost-effective, facile, rapid and industrially compatible fabrication technique of functional materials for various applications. In this review, we provide an account of the attempts of flexographic printing made to scale up functional materials on surfaces for biomedical applications. Firstly, we offer justification for demanding high-throughput fabrication techniques. We then present the facile working principle of the flexographic printing and its use in different medical applications, for example chronic disease monitoring devices, colorimetric sensors, electrochemical sensors, assays and drugs. Finally, we discuss challenges of the fabrication technique. The main purpose of this review is to give insights into the usefulness of flexographic printing to the health care industry.
Collapse
Affiliation(s)
| | - Nuha Al Habis
- Center of Excellence for Research in Engineering Materials, King Saud University, Riyadh, Saudi Arabia.
| | - Iftikhar Ahmad
- Center of Excellence for Research in Engineering Materials, King Saud University, Riyadh, Saudi Arabia
| | - Naif Ahmed Alshehri
- College of Science Physics Department at Albaha University, Albaha, Saudi Arabia
| | - Hamad F Alharbi
- Mechanical Engineering Department, King Saud University, Riyadh, Saudi Arabia; Center of Excellence for Research in Engineering Materials, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
55
|
Kaushik S, Thungon PD, Goswami P. Silk Fibroin: An Emerging Biocompatible Material for Application of Enzymes and Whole Cells in Bioelectronics and Bioanalytical Sciences. ACS Biomater Sci Eng 2020; 6:4337-4355. [PMID: 33455178 DOI: 10.1021/acsbiomaterials.9b01971] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Enzymes and whole cells serve as the active biological entities in a myriad of applications including bioprocesses, bioanalytics, and bioelectronics. Conserving the natural activity of these functional biological entities during their prolonged use is one of the major goals for validating their practical applications. Silk fibroin (SF) has emerged as a biocompatible material to interface with enzymes as well as whole cells. These biomaterials can be tailored both physically and chemically to create excellent scaffolds of different forms such as fibers, films, and powder for immobilization and stabilization of enzymes. The secondary structures of the SF-protein can be attuned to generate hydrophobic/hydrophilic pockets suitable to create the biocompatible microenvironments. The fibrous nature of the SF protein with a dominant hydrophobic property may also serve as an excellent support for promoting cellular adhesion and growth. This review compiles and discusses the recent literature on the application of SF as a biocompatible material at the interface of enzymes and cells in various fields, including the emerging area of bioelectronics and bioanalytical sciences.
Collapse
Affiliation(s)
- Sharbani Kaushik
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43201, United States
| | - Phurpa Dema Thungon
- Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
| | - Pranab Goswami
- Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
| |
Collapse
|
56
|
Akpe V, Kim TH, Brown CL, Cock IE. Circulating tumour cells: a broad perspective. J R Soc Interface 2020; 17:20200065. [PMCID: PMC7423436 DOI: 10.1098/rsif.2020.0065] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Accepted: 07/09/2020] [Indexed: 08/13/2023] Open
Abstract
Circulating tumour cells (CTCs) have recently been identified as valuable biomarkers for diagnostic and prognostic evaluations, as well for monitoring therapeutic responses to treatments. CTCs are rare cells which may be present as one CTC surrounded by approximately 1 million white blood cells and 1 billion red blood cells per millilitre of peripheral blood. Despite the various challenges in CTC detection, considerable progress in detection methods have been documented in recent times, particularly for methodologies incorporating nanomaterial-based platforms and/or integrated microfluidics. Herein, we summarize the importance of CTCs as biological markers for tumour detection, highlight their mechanism of cellular invasion and discuss the various challenges associated with CTC research, including vulnerability, heterogeneity, phenotypicity and size differences. In addition, we describe nanomaterial agents used for electrochemistry and surface plasmon resonance applications, which have recently been used to selectively capture cancer cells and amplify signals for CTC detection. The intrinsic properties of nanomaterials have also recently been exploited to achieve photothermal destruction of cancer cells. This review describes recent advancements and future perspectives in the CTC field.
Collapse
Affiliation(s)
- Victor Akpe
- School of Environment and Science, Griffith University, Nathan Campus, Queensland 4111, Australia
- Environmental Futures Research Institute, Griffith University, Nathan Campus, Queensland 4111, Australia
| | - Tak H. Kim
- School of Environment and Science, Griffith University, Nathan Campus, Queensland 4111, Australia
- Environmental Futures Research Institute, Griffith University, Nathan Campus, Queensland 4111, Australia
| | - Christopher L. Brown
- School of Environment and Science, Griffith University, Nathan Campus, Queensland 4111, Australia
- Environmental Futures Research Institute, Griffith University, Nathan Campus, Queensland 4111, Australia
| | - Ian E. Cock
- School of Environment and Science, Griffith University, Nathan Campus, Queensland 4111, Australia
- Environmental Futures Research Institute, Griffith University, Nathan Campus, Queensland 4111, Australia
| |
Collapse
|
57
|
Akpe V, Shiddiky MJA, Kim TH, Brown CL, Yamauchi Y, Cock IE. Cancer biomarker profiling using nanozyme containing iron oxide loaded with gold particles. J R Soc Interface 2020; 17:20200180. [PMID: 32574540 DOI: 10.1098/rsif.2020.0180] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Nanozymes are nanomaterials with intrinsic magnetism and superparamagnetic properties. In the presence of an external magnet, nanozyme particles aggregate and redisperse without a foreign attraction. We evaluated the performances of nanozyme by changing the biosensing platforms and substituting other biological variants for a complete cancer assay detection. We investigated the expression of morphological variants in the transmission of signals using an electrochemical method. The signal responses, including signal enhancement with the nanozyme (Au-Fe2O3), showed a wide capturing range (greater than 80%, from 102 to 105 cells ml-1 in phosphate-buffered saline buffer, pH 7.4). The platform showed a fast response time within a dynamic range of 10-105 cells ml-1 for the investigated T47D cancer cell line. We also obtained higher responses for anti-HER2 (human epidermal receptor 2)/streptavidin interface as the biosensing electrode in the presence of T47D cancer cells. The positive assay produced a sixfold increase in current output compared to the negative target or negative biological variant. We calculated the limit of detection at 0.4 U ml-1, and of quantitation at 4 U ml-1 (units per millilitre). However, blood volume amounts in clinical settings may constrain diagnosis and increase detection limit value significantly.
Collapse
Affiliation(s)
- Victor Akpe
- School of Environment and Science, Griffith University, Nathan Campus, Queensland 4111, Australia.,Environmental Futures Research Institute, Griffith University, Nathan Campus, Queensland 4111, Australia
| | - Muhammad J A Shiddiky
- School of Environment and Science, Griffith University, Nathan Campus, Queensland 4111, Australia.,Queensland Micro and Nanotechnology Centre, Griffith University, Nathan Campus, Queensland 4111, Australia
| | - Tak H Kim
- School of Environment and Science, Griffith University, Nathan Campus, Queensland 4111, Australia.,Environmental Futures Research Institute, Griffith University, Nathan Campus, Queensland 4111, Australia
| | - Christopher L Brown
- School of Environment and Science, Griffith University, Nathan Campus, Queensland 4111, Australia.,Environmental Futures Research Institute, Griffith University, Nathan Campus, Queensland 4111, Australia
| | - Yusuke Yamauchi
- School of Chemical Engineering and Australian Institute for Bioengineering and Nanotechnology (AIBN), University of Queensland, Brisbane, Queensland 4072, Australia
| | - Ian E Cock
- School of Environment and Science, Griffith University, Nathan Campus, Queensland 4111, Australia.,Environmental Futures Research Institute, Griffith University, Nathan Campus, Queensland 4111, Australia
| |
Collapse
|
58
|
Bollella P, Katz E. Enzyme-Based Biosensors: Tackling Electron Transfer Issues. SENSORS (BASEL, SWITZERLAND) 2020; 20:E3517. [PMID: 32575916 PMCID: PMC7349488 DOI: 10.3390/s20123517] [Citation(s) in RCA: 70] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Revised: 06/18/2020] [Accepted: 06/19/2020] [Indexed: 12/25/2022]
Abstract
This review summarizes the fundamentals of the phenomenon of electron transfer (ET) reactions occurring in redox enzymes that were widely employed for the development of electroanalytical devices, like biosensors, and enzymatic fuel cells (EFCs). A brief introduction on the ET observed in proteins/enzymes and its paradigms (e.g., classification of ET mechanisms, maximal distance at which is observed direct electron transfer, etc.) are given. Moreover, the theoretical aspects related to direct electron transfer (DET) are resumed as a guideline for newcomers to the field. Snapshots on the ET theory formulated by Rudolph A. Marcus and on the mathematical model used to calculate the ET rate constant formulated by Laviron are provided. Particular attention is devoted to the case of glucose oxidase (GOx) that has been erroneously classified as an enzyme able to transfer electrons directly. Thereafter, all tools available to investigate ET issues are reported addressing the discussions toward the development of new methodology to tackle ET issues. In conclusion, the trends toward upcoming practical applications are suggested as well as some directions in fundamental studies of bioelectrochemistry.
Collapse
Affiliation(s)
- Paolo Bollella
- Department of Chemistry and Biomolecular Science, Clarkson University, Potsdam, New York, NY 13699-5810, USA;
| | | |
Collapse
|
59
|
Othman AM, Wollenberger U. Amperometric biosensor based on coupling aminated laccase to functionalized carbon nanotubes for phenolics detection. Int J Biol Macromol 2020; 153:855-864. [DOI: 10.1016/j.ijbiomac.2020.03.049] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Revised: 02/29/2020] [Accepted: 03/08/2020] [Indexed: 01/21/2023]
|
60
|
Elewi AS, Al-Shammaree SAW, AL Sammarraie AKM. Hydrogen peroxide biosensor based on hemoglobin-modified gold nanoparticles–screen printed carbon electrode. SENSING AND BIO-SENSING RESEARCH 2020. [DOI: 10.1016/j.sbsr.2020.100340] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
61
|
Real-time glucose monitoring system containing enzymatic sensor and enzymatic reference electrodes. Biosens Bioelectron 2020; 164:112338. [PMID: 32553347 DOI: 10.1016/j.bios.2020.112338] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Revised: 05/15/2020] [Accepted: 05/28/2020] [Indexed: 01/31/2023]
Abstract
Every electrochemical biosensor uses two or three electrode setup, which involves sensing electrode for a specific reaction, metal/salt reference electrode (i.e., Ag/AgCl or Hg/Hg2Cl2) for the control of the potential and, is some cases, counter electrode for the compensation of the current. This setup has significant flaws related to metal/salt reference electrodes: they are bulky and difficult to miniaturize, leak electrolyte to the medium, lose the ability to define the electrochemical potential precisely in time, consequently, have to be updated or replaced. This causes problems when the biosensor cannot be easily replaced (e.g., implanted electronics). Here we present a fully enzymatic real-time glucose monitoring system capable of referencing its own electrochemical potential. Using sensing electrode composed of wired glucose dehydrogenase and enzymatic reference electrode composed of wired laccase we have created a stable and accurate electrode system, which measured fluxes in concentration of glucose in a physiological range (3-8 mM), and demonstrated performance of the designed system in undiluted human serum. In addition, our designed enzymatic reference electrode is universal and may be applied for other biosensors, thus open possibilities for the new generation of implantable devices for healthcare monitoring.
Collapse
|
62
|
Kucherenko IS, Soldatkin OO, Dzyadevych SV, Soldatkin AP. Electrochemical biosensors based on multienzyme systems: Main groups, advantages and limitations - A review. Anal Chim Acta 2020; 1111:114-131. [PMID: 32312388 DOI: 10.1016/j.aca.2020.03.034] [Citation(s) in RCA: 59] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2019] [Revised: 03/14/2020] [Accepted: 03/16/2020] [Indexed: 12/13/2022]
Abstract
In the review, the principles and main purposes of using multienzyme systems in electrochemical biosensors are analyzed. Coupling several enzymes allows an extension of the spectrum of detectable substances, an increase in the biosensor sensitivity (in some cases, by several orders of magnitude), and an improvement of the biosensor selectivity, as showed on the examples of amperometric, potentiometric, and conductometric biosensors. The biosensors based on cascade, cyclic and competitive enzyme systems are described alongside principles of function, advantages, disadvantages and practical use for real sample analyses in various application areas (food production and quality control, clinical diagnostics, environmental monitoring). The complications and restrictions regarding the development of multienzyme biosensors are evaluated. The recommendations on the reasonability of elaboration of novel multienzyme biosensors are given.
Collapse
Affiliation(s)
- I S Kucherenko
- Department of Biomolecular Electronics, Institute of Molecular Biology and Genetics of the National Academy of Sciences of Ukraine, Zabolotnogo Street 150, 03148, Kyiv, Ukraine.
| | - O O Soldatkin
- Department of Biomolecular Electronics, Institute of Molecular Biology and Genetics of the National Academy of Sciences of Ukraine, Zabolotnogo Street 150, 03148, Kyiv, Ukraine; Institute of High Technologies, Taras Shevchenko National University of Kyiv, Volodymyrska Street 64, 01003, Kyiv, Ukraine
| | - S V Dzyadevych
- Department of Biomolecular Electronics, Institute of Molecular Biology and Genetics of the National Academy of Sciences of Ukraine, Zabolotnogo Street 150, 03148, Kyiv, Ukraine; Institute of High Technologies, Taras Shevchenko National University of Kyiv, Volodymyrska Street 64, 01003, Kyiv, Ukraine
| | - A P Soldatkin
- Department of Biomolecular Electronics, Institute of Molecular Biology and Genetics of the National Academy of Sciences of Ukraine, Zabolotnogo Street 150, 03148, Kyiv, Ukraine; Institute of High Technologies, Taras Shevchenko National University of Kyiv, Volodymyrska Street 64, 01003, Kyiv, Ukraine
| |
Collapse
|
63
|
Xu S, Liu Y, Zhao W, Wu Q, Chen Y, Huang X, Sun Z, Zhu Y, Liu X. Hierarchical 0D-2D bio-composite film based on enzyme-loaded polymeric nanoparticles decorating graphene nanosheets as a high-performance bio-sensing platform. Biosens Bioelectron 2020; 156:112134. [PMID: 32275578 DOI: 10.1016/j.bios.2020.112134] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2019] [Revised: 02/19/2020] [Accepted: 03/03/2020] [Indexed: 11/18/2022]
Abstract
Herein, we developed a hierarchical bio-composite sensing film by facile one-step electro-deposition of 0D enzyme-polymer nanoparticles (NPs) with 2D graphene oxide nanosheets as conductive supports and nanofillers, based on which an effective and robust enzymatic biosensor platform was constructed. Horseradish peroxidase (HRP) as a model enzyme was co-assembled with a photo-cross-linkable polypeptide of 2-hydroxyethyl methacrylate modified poly(γ-glutamic acid) (γ-PGA-HEMA), generating hybrid HRP@γ-PGA-HEMA nanoparticles (HRP@PGH NPs). Then HRP@PGH NPs and graphene oxide nanosheets (GO NSs) were simultaneously electrodeposited onto the electrode surface, obtaining a hierarchical 0D-2D bio-composite film. After subsequent electrochemical reduction of GO NSs into graphene nanosheets (GNSs) and following photo-cross-linking, the resultant nanostructured HRP@PGH/GNSs sensing film was successfully applied to construct an enzymatic biosensor for hydrogen peroxide (H2O2). The biosensor exerted high sensitivity, fast response, and good stability for H2O2 sensing. Satisfactory results were also demonstrated for its practical application in human serum samples, suggesting a promising application potential in biomedical diagnostics. The one-step generated 0D-2D bio-composite sensing film demonstrates synergetic effects from both the soft nanoparticles and hard conductive nanosheets, which would enlighten the innovative construction of composite nanomaterials and nanoarchitectonics for bio-sensing systems.
Collapse
Affiliation(s)
- Sheng Xu
- Key Laboratory of Synthetic and Biological Colloids, Ministry of Education, School of Chemical and Material Engineering, Jiangnan University, Wuxi, 214122, Jiangsu Province, PR China; School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, United States
| | - Yayuan Liu
- Key Laboratory of Synthetic and Biological Colloids, Ministry of Education, School of Chemical and Material Engineering, Jiangnan University, Wuxi, 214122, Jiangsu Province, PR China
| | - Wei Zhao
- Key Laboratory of Synthetic and Biological Colloids, Ministry of Education, School of Chemical and Material Engineering, Jiangnan University, Wuxi, 214122, Jiangsu Province, PR China
| | - Qian Wu
- Key Laboratory of Synthetic and Biological Colloids, Ministry of Education, School of Chemical and Material Engineering, Jiangnan University, Wuxi, 214122, Jiangsu Province, PR China
| | - Yanru Chen
- Key Laboratory of Synthetic and Biological Colloids, Ministry of Education, School of Chemical and Material Engineering, Jiangnan University, Wuxi, 214122, Jiangsu Province, PR China
| | - Xuewen Huang
- Key Laboratory of Synthetic and Biological Colloids, Ministry of Education, School of Chemical and Material Engineering, Jiangnan University, Wuxi, 214122, Jiangsu Province, PR China
| | - Zhijian Sun
- School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, United States
| | - Ye Zhu
- Key Laboratory of Synthetic and Biological Colloids, Ministry of Education, School of Chemical and Material Engineering, Jiangnan University, Wuxi, 214122, Jiangsu Province, PR China.
| | - Xiaoya Liu
- Key Laboratory of Synthetic and Biological Colloids, Ministry of Education, School of Chemical and Material Engineering, Jiangnan University, Wuxi, 214122, Jiangsu Province, PR China.
| |
Collapse
|
64
|
Rawal R, Kharangarh PR, Dawra S, Tomar M, Gupta V, Pundir C. A comprehensive review of bilirubin determination methods with special emphasis on biosensors. Process Biochem 2020. [DOI: 10.1016/j.procbio.2019.10.034] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
65
|
Barbosa C, Silveira CM, Silva D, Brissos V, Hildebrandt P, Martins LO, Todorovic S. Immobilized dye-decolorizing peroxidase (DyP) and directed evolution variants for hydrogen peroxide biosensing. Biosens Bioelectron 2020; 153:112055. [PMID: 32056659 DOI: 10.1016/j.bios.2020.112055] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Revised: 01/24/2020] [Accepted: 01/26/2020] [Indexed: 02/07/2023]
Abstract
Immobilized dye-decolorizing peroxidase from Pseudomonas putida MET94 (PpDyP) and three variants generated by directed evolution (DE) are studied aiming at the design of a biosensor for H2O2 detection. Structural properties of the enzymes in solution and immobilized state are addressed by resonance Raman (RR) and surface enhanced RR (SERR) spectroscopy, and the electrocatalytic properties are analyzed by electrochemistry. The wild-type (wt) and 29E4 variant (with E188K and H125Y mutations) represent excellent candidates for development of H2O2 biosensors, since they exhibit a good dynamic response range (1-200 μM H2O2), short response times (2 s) and a superior sensitivity (1.3-1.4 A⋅M-1⋅cm-2) for H2O2, as well as selectivity and long term stability. In contrast to the solution state, 6E10 (with E188K, A142V and H125Y mutations) and 25F6 (with E188K, A142V, H125Y and G129D mutations) variants display much lower activity and are inhibited by high concentrations of H2O2 upon adsorption on an electrode. In terms of sensitivity, the bioelectrodes employing wt PpDyP and 29E4 variant outperform HRP based counterparts reported in the literature by 1-4 orders of magnitude. We propose the development of wt or 29E4 PpDyP based biosensor as a valuable alternative to devices that rely on peroxidases.
Collapse
Affiliation(s)
- Catarina Barbosa
- Instituto de Tecnologia Química e Biológica António Xavier, Universidade NOVA de Lisboa, Av. da República, 2780-157, Oeiras, Portugal
| | - Célia M Silveira
- Instituto de Tecnologia Química e Biológica António Xavier, Universidade NOVA de Lisboa, Av. da República, 2780-157, Oeiras, Portugal
| | - Diogo Silva
- Instituto de Tecnologia Química e Biológica António Xavier, Universidade NOVA de Lisboa, Av. da República, 2780-157, Oeiras, Portugal
| | - Vânia Brissos
- Instituto de Tecnologia Química e Biológica António Xavier, Universidade NOVA de Lisboa, Av. da República, 2780-157, Oeiras, Portugal
| | - Peter Hildebrandt
- Technische Universität Berlin, Inbstitut für Chemie, Sekr. PC14, Straße des 17. Juni 135, D-10623, Berlin, Germany
| | - Lígia O Martins
- Instituto de Tecnologia Química e Biológica António Xavier, Universidade NOVA de Lisboa, Av. da República, 2780-157, Oeiras, Portugal
| | - Smilja Todorovic
- Instituto de Tecnologia Química e Biológica António Xavier, Universidade NOVA de Lisboa, Av. da República, 2780-157, Oeiras, Portugal.
| |
Collapse
|
66
|
Saravanan N, Senthil Kumar A. Molecular wiring of glucose oxidase enzyme with Mn polypyridine complex on MWCNT modified electrode surface and its bio-electrocatalytic oxidation and glucose sensing. Methods Enzymol 2020; 630:249-262. [PMID: 31931988 DOI: 10.1016/bs.mie.2019.10.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
Abstract
A simple method for molecular wiring of glucose oxidase (GOx) enzyme with a low cost Mn polypyridine complex, Mn(phen)2Cl2, carboxylic acid functionalized multiwalled carbon nanotube (f-MWCNT) and Nafion (Nf), which is useful for glucose oxidation and sensing application in pH 7 phosphate buffer solution, has been demonstrated. In the typical preparation, f-MWCNT, Mn(phen)2Cl2, Nafion and GOx solution/suspension were successfully drop-casted as layer-by-layer on a cleaned glassy carbon electrode and potential cycled using cylic voltametric (CV) technique. In this preparation procedure, the Mn(phen)2Cl2 complex is in-situ converted as a dimer complex, Mn2(phen)2(O)(Cl2). A cooperative interaction based on π-π, covalent, ionic, hydrophilic and hydrophobic are operated in the bioelectrode for molecular wiring and electron-transfer shutting reaction. The modified electrode is designated as GCE/f-MWCNT@Mn2(phen)2(O)(Cl2)-Nf@GOx. CV response of the bioelectrode showed a defined redox peak current signal at an apparent standard electrode potential, E°'=0.55V vs Ag/AgCl. Upon exposure of glucose, the modified electrode showed a current linearity in a range, 0-6mM with a current sensitivity value, 349.4μAmM-1cm-2 by CV and a current linearity in a window, 50-550μM with a current sensitivity, 316.8μAmM-1cm-2 at applied biased potential, 0.65V vs Ag/AgCl by amperometric i-t methods. Obtained glucose oxidation current sensitivity values are relatively higher than Os-complex based transducer systems.
Collapse
Affiliation(s)
- Natarajan Saravanan
- Nano and Bioelectrochemistry Research Laboratory, Department of Chemistry, School of Advanced Sciences, Vellore Institute of Technology, Vellore, India
| | - Annamalai Senthil Kumar
- Nano and Bioelectrochemistry Research Laboratory, Department of Chemistry, School of Advanced Sciences, Vellore Institute of Technology, Vellore, India; Carbon Dioxide Research and Green Technology Centre, Vellore Institute of Technology, Vellore, India.
| |
Collapse
|
67
|
Alagappan M, Immanuel S, Sivasubramanian R, Kandaswamy A. Development of cholesterol biosensor using Au nanoparticles decorated f-MWCNT covered with polypyrrole network. ARAB J CHEM 2020. [DOI: 10.1016/j.arabjc.2018.02.018] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
|
68
|
Abstract
In vivo electrochemical sensing based on implantable microelectrodes is a strong driving force of analytical neurochemistry in brain. The complex and dynamic neurochemical network sets stringent standards of in vivo electrochemical sensors including high spatiotemporal resolution, selectivity, sensitivity, and minimized disturbance on brain function. Although advanced materials and novel technologies have promoted the development of in vivo electrochemical sensors drastically, gaps with the goals still exist. This Review mainly focuses on recent attempts on the key issues of in vivo electrochemical sensors including selectivity, tissue response and sensing reliability, and compatibility with electrophysiological techniques. In vivo electrochemical methods with bare carbon fiber electrodes, of which the selectivity is achieved either with electrochemical techniques such as fast-scan cyclic voltammetry and differential pulse voltammetry or based on the physiological nature will not be reviewed. Following the elaboration of each issue involved in in vivo electrochemical sensors, possible solutions supported by the latest methodological progress will be discussed, aiming to provide inspiring and practical instructions for future research.
Collapse
Affiliation(s)
- Cong Xu
- Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Fei Wu
- Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Ping Yu
- Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Lanqun Mao
- Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
69
|
López Marzo AM, Mayorga-Martinez CC, Pumera M. 3D-printed graphene direct electron transfer enzyme biosensors. Biosens Bioelectron 2019; 151:111980. [PMID: 31999587 DOI: 10.1016/j.bios.2019.111980] [Citation(s) in RCA: 72] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 12/17/2019] [Accepted: 12/19/2019] [Indexed: 01/26/2023]
Abstract
Three-dimensional (3D) printing technology offers attractive possibilities for many fields. In electrochemistry, 3D printing technology has been used to fabricate customized 3D-printed electrodes as a platform to develop bio/sensing, energy generation and storage devices. Here, we use a 3D-printed graphene/polylactic (PLA) electrode made by additive manufacturing technology and immobilize horseradish peroxidase (HRP) to create a direct electron transfer enzyme-based biosensors for hydrogen peroxide detection. Gold nanoparticles are included in the system to confirm and facilitate heterogeneous electron transfer. This work opens a new direction for the fabrication of third-generation electrochemical biosensors using 3D printing technology, with implications for applications in the environmental and biomedical fields.
Collapse
Affiliation(s)
- Adaris M López Marzo
- Center for Advanced Functional Nanorobots, Department of Inorganic Chemistry, University of Chemistry and Technology Prague, Technická 5, 166 28, Prague 6, Czech Republic
| | - Carmen C Mayorga-Martinez
- Center for Advanced Functional Nanorobots, Department of Inorganic Chemistry, University of Chemistry and Technology Prague, Technická 5, 166 28, Prague 6, Czech Republic
| | - Martin Pumera
- Center for Advanced Functional Nanorobots, Department of Inorganic Chemistry, University of Chemistry and Technology Prague, Technická 5, 166 28, Prague 6, Czech Republic; Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, South Korea; Department of Medical Research, China Medical University Hospital, China Medical University, No. 91 Hsueh-Shih Road, Taichung, Taiwan; Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, Brno, CZ-616 00, Czech Republic.
| |
Collapse
|
70
|
Nanocatalysts Containing Direct Electron Transfer-Capable Oxidoreductases: Recent Advances and Applications. Catalysts 2019. [DOI: 10.3390/catal10010009] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Direct electron transfer (DET)-capable oxidoreductases are enzymes that have the ability to transfer/receive electrons directly to/from solid surfaces or nanomaterials, bypassing the need for an additional electron mediator. More than 100 enzymes are known to be capable of working in DET conditions; however, to this day, DET-capable enzymes have been mainly used in designing biofuel cells and biosensors. The rapid advance in (semi) conductive nanomaterial development provided new possibilities to create enzyme-nanoparticle catalysts utilizing properties of DET-capable enzymes and demonstrating catalytic processes never observed before. Briefly, such nanocatalysts combine several cathodic and anodic catalysis performing oxidoreductases into a single nanoparticle surface. Hereby, to the best of our knowledge, we present the first review concerning such nanocatalytic systems involving DET-capable oxidoreductases. We outlook the contemporary applications of DET-capable enzymes, present a principle of operation of nanocatalysts based on DET-capable oxidoreductases, provide a review of state-of-the-art (nano) catalytic systems that have been demonstrated using DET-capable oxidoreductases, and highlight common strategies and challenges that are usually associated with those type catalytic systems. Finally, we end this paper with the concluding discussion, where we present future perspectives and possible research directions.
Collapse
|
71
|
Scaling up Photoelectrocatalytic Reactors: A TiO2 Nanotube-Coated Disc Compound Reactor Effectively Degrades Acetaminophen. WATER 2019. [DOI: 10.3390/w11122522] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Multiple discs coated with hierarchically-organized TiO2 anatase nanotubes served as photoelectrodes in a novel annular photoelectrocatalytic reactor. Electrochemical characterization showed light irradiation enhanced the current response due to photogeneration of charge carriers. The pharmaceutical acetaminophen was used as a representative water micropollutant. The photoelectrocatalysis pseudo-first-order rate constant for acetaminophen was seven orders of magnitude greater than electrocatalytic treatment. Compared against photocatalysis alone, our photoelectrocatalytic reactor at <8 V reduced by two fold, the electric energy per order (EEO; kWh m−3 order−1 for 90% pollutant degradation). Applying a cell potential higher than 8 V detrimentally increased EEO. Acetaminophen was degraded across a range of initial concentrations, but absorbance at higher concentration diminished photon transport, resulting in higher EEO. Extended photoelectrocatalytic reactor operation degraded acetaminophen, which was accompanied by 53% mineralization based upon total organic carbon measurements. This proof of concept for our photoelectrocatalytic reactor demonstrated a strategy to increase photo-active surface area in annular reactors.
Collapse
|
72
|
Tonello S, Stradolini F, Abate G, Uberti D, Serpelloni M, Carrara S, Sardini E. Electrochemical detection of different p53 conformations by using nanostructured surfaces. Sci Rep 2019; 9:17347. [PMID: 31758050 PMCID: PMC6874615 DOI: 10.1038/s41598-019-53994-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2019] [Accepted: 11/07/2019] [Indexed: 11/09/2022] Open
Abstract
Protein electrochemistry represents a powerful technique for investigating the function and structure of proteins. Currently available biochemical assays provide limited information related to the conformational state of proteins and high costs. This work provides novel insights into the electrochemical investigation of the metalloprotein p53 and its redox products using label-free direct electrochemistry and label-based antibody-specific approaches. First, the redox activities of different p53 redox products were qualitatively investigated on carbon-based electrodes. Then, focusing on the open p53 isoform (denatured p53), a quantitative analysis was performed, comparing the performances of different bulk and nanostructured materials (carbon and platinum). Overall, four different p53 products could be successfully discriminated, from wild type to denatured. Label-free analysis suggested a single electron exchange with electron transfer rate constants on the order of 1 s-1. Label-based analysis showed decreasing affinity of pAb240 towards denatured, oxidized and nitrated p53. Furthermore, platinum nanostructured electrodes showed the highest enhancement of the limit of detection in the quantitative analysis (100 ng/ml). Overall, the obtained results represent a first step towards the implementation of highly requested complex integrated devices for clinical practices, with the aim to go beyond simple protein quantification.
Collapse
Affiliation(s)
- Sarah Tonello
- Department of Information Engineering, University of Brescia, Brescia, Italy.
| | | | - Giulia Abate
- Department of Molecular and Translational Medicine, University of Brescia, Brescia, Italy
| | - Daniela Uberti
- Department of Molecular and Translational Medicine, University of Brescia, Brescia, Italy
| | - Mauro Serpelloni
- Department of Information Engineering, University of Brescia, Brescia, Italy
| | - Sandro Carrara
- Integrated Systems Laboratory (LSI), EPFL, Lausanne, Switzerland
| | - Emilio Sardini
- Department of Information Engineering, University of Brescia, Brescia, Italy
| |
Collapse
|
73
|
Zhang D, Chen X, Ma W, Yang T, Li D, Dai B, Zhang Y. Direct electrochemistry of glucose oxidase based on one step electrodeposition of reduced graphene oxide incorporating polymerized l-lysine and its application in glucose sensing. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 104:109880. [DOI: 10.1016/j.msec.2019.109880] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Revised: 01/22/2019] [Accepted: 06/10/2019] [Indexed: 10/26/2022]
|
74
|
Xie H, Luo G, Niu Y, Weng W, Zhao Y, Ling Z, Ruan C, Li G, Sun W. Synthesis and utilization of Co 3O 4 doped carbon nanofiber for fabrication of hemoglobin-based electrochemical sensor. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 107:110209. [PMID: 31761232 DOI: 10.1016/j.msec.2019.110209] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2019] [Revised: 09/02/2019] [Accepted: 09/15/2019] [Indexed: 12/25/2022]
Abstract
In this paper cobalt oxide (Co3O4) nanoparticles were mixed with polyacrylonitrile to prepare Co3O4 doped carbon nanofiber (CNF) composite by electrospinning and carbonization, which was further used to modify on carbon ionic liquid electrode (CILE). Hemoglobin (Hb) was immobilized on Co3O4-CNF/CILE surface with Nafion acted as the protective film to fabricate an electrochemical biosensor (Nafion/Hb/Co3O4-CNF/CILE). Electrochemical behavior of Hb on the electrode was investigated with a pair of quasi-reversible redox peak appeared on cyclic voltammogram and electrochemical parameters were calculated. Moreover, this biosensor had good analytical capabilities for electrocatalytic reduction of different substrates including trichloroacetic acid, potassium bromate and sodium nitrite with wider detection range from 40.0 to 260.0 mmol L-1, 0.1 to 48.0 mmol L-1 and 1.0 to 12.0 mmol L-1 by cyclic voltammetry, respectively. The proposed method showed excellent anti-interferences ability with good selectivity and was successful used for quantitative detection of real samples, which displayed the potential applications to develop into a new analytical device.
Collapse
Affiliation(s)
- Hui Xie
- Key Laboratory of Laser Technology and Optoelectronic Functional Materials of Hainan Province, College of Chemistry and Chemical Engineering, Hainan Normal University, Haikou, 571158, PR China
| | - Guiling Luo
- Key Laboratory of Laser Technology and Optoelectronic Functional Materials of Hainan Province, College of Chemistry and Chemical Engineering, Hainan Normal University, Haikou, 571158, PR China
| | - Yanyan Niu
- Key Laboratory of Laser Technology and Optoelectronic Functional Materials of Hainan Province, College of Chemistry and Chemical Engineering, Hainan Normal University, Haikou, 571158, PR China
| | - Wenju Weng
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science of Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Yixing Zhao
- Key Laboratory of Laser Technology and Optoelectronic Functional Materials of Hainan Province, College of Chemistry and Chemical Engineering, Hainan Normal University, Haikou, 571158, PR China
| | - Zhiqiang Ling
- Key Laboratory of Laser Technology and Optoelectronic Functional Materials of Hainan Province, College of Chemistry and Chemical Engineering, Hainan Normal University, Haikou, 571158, PR China
| | - Chengxiang Ruan
- Jiangxi Key Laboratory of Surface Engineering, Jiangxi Science and Technology Normal University, Nanchang, 330013, PR China
| | - Guangjiu Li
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science of Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Wei Sun
- Key Laboratory of Laser Technology and Optoelectronic Functional Materials of Hainan Province, College of Chemistry and Chemical Engineering, Hainan Normal University, Haikou, 571158, PR China.
| |
Collapse
|
75
|
Dhanjai, Balla P, Sinha A, Wu L, Lu X, Tan D, Chen J. Co3O4 nanoparticles supported mesoporous carbon framework interface for glucose biosensing. Talanta 2019; 203:112-121. [DOI: 10.1016/j.talanta.2019.05.056] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Revised: 05/04/2019] [Accepted: 05/12/2019] [Indexed: 01/24/2023]
|
76
|
Morlighem JÉRL, Radis-Baptista G. The Place for Enzymes and Biologically Active Peptides from Marine Organisms for Application in Industrial and Pharmaceutical Biotechnology. Curr Protein Pept Sci 2019; 20:334-355. [PMID: 30255754 DOI: 10.2174/1389203719666180926121722] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2018] [Revised: 09/10/2018] [Accepted: 09/15/2018] [Indexed: 01/07/2023]
Abstract
Since the beginning of written history, diverse texts have reported the use of enzymatic preparations in food processing and have described the medicinal properties of crude and fractionated venoms to treat various diseases and injuries. With the biochemical characterization of enzymes from distinct sources and bioactive polypeptides from animal venoms, the last sixty years have testified the advent of industrial enzymology and protein therapeutics, which are currently applicable in a wide variety of industrial processes, household products, and pharmaceuticals. Bioprospecting of novel biocatalysts and bioactive peptides is propelled by their unsurpassed properties that are applicable for current and future green industrial processes, biotechnology, and biomedicine. The demand for both novel enzymes with desired characteristics and novel peptides that lead to drug development, has experienced a steady increase in response to the expanding global market for industrial enzymes and peptidebased drugs. Moreover, although largely unexplored, oceans and marine realms, with their unique ecosystems inhabited by a large variety of species, including a considerable number of venomous animals, are recognized as untapped reservoirs of molecules and macromolecules (enzymes and bioactive venom-derived peptides) that can potentially be converted into highly valuable biopharmaceutical products. In this review, we have focused on enzymes and animal venom (poly)peptides that are presently in biotechnological use, and considering the state of prospection of marine resources, on the discovery of useful industrial biocatalysts and drug leads with novel structures exhibiting selectivity and improved performance.
Collapse
Affiliation(s)
- Jean-Étienne R L Morlighem
- Institute for Marine Sciences, Federal University of Ceara, Av da Abolicao 3207. Fortaleza/CE. 60165081, Brazil
| | - Gandhi Radis-Baptista
- Institute for Marine Sciences, Federal University of Ceara, Av da Abolicao 3207. Fortaleza/CE. 60165081, Brazil
| |
Collapse
|
77
|
|
78
|
Ruzgas T, Larpant N, Shafaat A, Sotres J. Wireless, Battery‐Less Biosensors Based on Direct Electron Transfer Reactions. ChemElectroChem 2019. [DOI: 10.1002/celc.201901015] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Tautgirdas Ruzgas
- Department of Biomedical Science Faculty of Health and SocietyMalmö University 205 06 Malmö Sweden
- Biofilms – Research Center for BiointerfacesMalmö University 205 06 Malmö Sweden
| | - Nutcha Larpant
- Graduate Program in Clinical Biochemistry and Molecular Medicine Faculty of Allied Health SciencesChulalongkorn University Patumwan Bangkok 10330 Thailand
| | - Atefeh Shafaat
- Department of Biomedical Science Faculty of Health and SocietyMalmö University 205 06 Malmö Sweden
- Biofilms – Research Center for BiointerfacesMalmö University 205 06 Malmö Sweden
| | - Javier Sotres
- Department of Biomedical Science Faculty of Health and SocietyMalmö University 205 06 Malmö Sweden
- Biofilms – Research Center for BiointerfacesMalmö University 205 06 Malmö Sweden
| |
Collapse
|
79
|
Koh M, Cho HY, Yu C, Choi S, Lee KB, Schultz PG. Site-Specific Incorporation of a Dithiolane Containing Amino Acid into Proteins. Bioconjug Chem 2019; 30:2102-2105. [PMID: 31319026 DOI: 10.1021/acs.bioconjchem.9b00413] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
We have genetically encoded a dithiolane containing amino acid (dtF) in Escherichia coli (E. coli) using a polyspecific aminoacyl-tRNA synthetase (aaRS)/amber suppressor tRNA pair. To demonstrate the utility of dtF for bioapplications, we synthesized gold nanoparticle (AuNP) constructs with a mutant superfolder green fluorescent protein (sfGFP) [sfGFP-AuNP] as a model for the protein-metal conjugation. The resulting sfGFP-AuNP constructs show directional homogeneity and enhanced chemical durability compared to their cysteine analogues toward excess environmental 1,4-dithiothreitol (DTT).
Collapse
Affiliation(s)
- Minseob Koh
- Department of Chemistry and Skaggs Institute for Chemical Biology , The Scripps Research Institute , 10550 N. Torrey Pines Road , La Jolla , California 92037 , United States
| | - Hyeon-Yeol Cho
- Department of Chemistry and Chemical Biology , Rutgers, The State University of New Jersey , Piscataway , New Jersey 08854 , United States
| | - Chenguang Yu
- Department of Chemistry and Skaggs Institute for Chemical Biology , The Scripps Research Institute , 10550 N. Torrey Pines Road , La Jolla , California 92037 , United States
| | - Seihyun Choi
- Department of Chemistry and Skaggs Institute for Chemical Biology , The Scripps Research Institute , 10550 N. Torrey Pines Road , La Jolla , California 92037 , United States
| | - Ki-Bum Lee
- Department of Chemistry and Chemical Biology , Rutgers, The State University of New Jersey , Piscataway , New Jersey 08854 , United States.,Department of Life and Nanopharmaceutical Science, College of Pharmacy , Kyung Hee University , Seoul 02447 , Republic of Korea
| | - Peter G Schultz
- Department of Chemistry and Skaggs Institute for Chemical Biology , The Scripps Research Institute , 10550 N. Torrey Pines Road , La Jolla , California 92037 , United States
| |
Collapse
|
80
|
Wang H, Teng F, Zhang L, Zhang Q, Zhang H, Pei T, Li S, Xia L. Meso-Cellular Silicate Foam-Modified Reduced Graphene Oxide with a Sandwich Structure for Enzymatic Immobilization and Bioelectrocatalysis. ACS APPLIED MATERIALS & INTERFACES 2019; 11:29522-29535. [PMID: 31347823 DOI: 10.1021/acsami.9b08569] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
An integrated composite of meso-cellular silicate foam (MCF)-modified reduced graphene oxide (MCF@rGO) was designed and synthesized based on polyethylene oxide-polypropylene oxide-polyethylene oxide (P123)-modified rGO (P123-rGO). As the polymeric template for the fabrication of mesoporous silicates, modified P123 greatly improved the affinity between the nanosheet and the in situ formed MCFs, resulting in the formation of thin layers of MCFs on both sides of rGO. Therefore, the MCFs@rGO formed exhibited a unique sandwich structure with an inner skeleton of rGO and two outer layers of MCFs. The outer modification by MCFs, with the presence of large mesopores, not only shifted the surface property of rGO from hydrophobic to hydrophilic but also offered immobilized enzymes a favorable microenvironment to maintain their bioactivity. Meanwhile, the inner skeleton of rGO compensated for the weak conductivity of MCFs, providing a pathway for the direct electron transfer (DET) of various redox enzymes or proteins, such as hemoglobin (Hb), horseradish peroxidase, glucose oxidase (GOD), and cholesterol oxidase. It was found that the DET signal obtained from Hb-MCFs@rGO/glassy carbon electrode (GCE) was much larger than the sum of the signals from two components-based modified electrodes of Hb-P123-rGO/GCE and Hb-MCFs/GCE. A similar improvement in DET signal was also observed using GOD-MCFs@rGO/GCE. The significant enhancement of DET signals for both protein electrodes can be ascribed to the synergistic effects generated from the integration of the two components, one of which enhances biocompatibility and the other enhances conductivity. The bioelectrocatalytic performance of Hb and GOD electrodes was further investigated. As for Hb-MCFs@rGO/GCE, the GOD electrode displayed excellent analytical performance for the detection of hydrogen peroxide (H2O2), including a good sensitivity of 0.25 μA μmol-1 L cm-2, a low detection limit of 63.6 nmol L-1 based on S/N = 3, and a low apparent Michaelis-Menten constant (KMapp) of 49.05 μmol L-1. GOD-MCFs@rGO/GCE also exhibited good analytical performance for the detection of glucose, with a wide linear range of 0.25-8.0 mmol L-1. In addition, blood glucose detection in samples of human serum was successfully achieved using GOD-MCFs@rGO/GCE with a low quantification limit.
Collapse
Affiliation(s)
- Huiting Wang
- College of Chemistry , Liaoning University , Shenyang 110036 , China
| | - Fei Teng
- College of Chemistry , Liaoning University , Shenyang 110036 , China
| | - Ling Zhang
- College of Chemistry and Chemical Engineering , Shenyang Normal University , Shenyang 110034 , China
- Key Laboratory of Functional Inorganic Material Chemistry, Ministry of Education of the People's Republic of China , Heilongjiang University , Harbin 150080 , China
| | - Qian Zhang
- College of Chemistry , Liaoning University , Shenyang 110036 , China
- Key Laboratory of Functional Inorganic Material Chemistry, Ministry of Education of the People's Republic of China , Heilongjiang University , Harbin 150080 , China
| | - Hairan Zhang
- College of Chemistry , Liaoning University , Shenyang 110036 , China
| | - Tingting Pei
- College of Chemistry , Liaoning University , Shenyang 110036 , China
| | - Shun Li
- College of Chemistry , Liaoning University , Shenyang 110036 , China
| | - Lixin Xia
- College of Chemistry , Liaoning University , Shenyang 110036 , China
| |
Collapse
|
81
|
Reginald SS, Lee YS, Lee H, Jang N, Chang IS. Electrocatalytic and Biosensing Properties of Aerobic Carbon Monoxide Dehydrogenase from
Hydrogenophaga Pseudoflava
Immobilized on Au Electrode towards Carbon Monoxide Oxidation. ELECTROANAL 2019. [DOI: 10.1002/elan.201800666] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Stacy Simai Reginald
- School of Earth Sciences and Environmental EngineeringGwangju Institute of Science and Technology (GIST) 123 Cheomdan-gwagiro, Bukgu Gwangju 61005 Republic of Korea
| | - Yoo Seok Lee
- School of Earth Sciences and Environmental EngineeringGwangju Institute of Science and Technology (GIST) 123 Cheomdan-gwagiro, Bukgu Gwangju 61005 Republic of Korea
| | - Hyeryeong Lee
- School of Earth Sciences and Environmental EngineeringGwangju Institute of Science and Technology (GIST) 123 Cheomdan-gwagiro, Bukgu Gwangju 61005 Republic of Korea
| | - Nulee Jang
- School of Earth Sciences and Environmental EngineeringGwangju Institute of Science and Technology (GIST) 123 Cheomdan-gwagiro, Bukgu Gwangju 61005 Republic of Korea
| | - In Seop Chang
- School of Earth Sciences and Environmental EngineeringGwangju Institute of Science and Technology (GIST) 123 Cheomdan-gwagiro, Bukgu Gwangju 61005 Republic of Korea
| |
Collapse
|
82
|
Schmitz LM, Rosenthal K, Lütz S. Enzyme-Based Electrobiotechnological Synthesis. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2019; 167:87-134. [PMID: 29134460 DOI: 10.1007/10_2017_33] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Oxidoreductases are enzymes with a high potential for organic synthesis, as their selectivity often exceeds comparable chemical syntheses. The biochemical cofactors of these enzymes need regeneration during synthesis. Several regeneration methods are available but the electrochemical approach offers an efficient and quasi mass-free method for providing the required redox equivalents. Electron transfer systems involving direct regeneration of natural and artificial cofactors, indirect electrochemical regeneration via a mediator, and indirect electroenzymatic cofactor regeneration via enzyme and mediator have been investigated. This chapter gives an overview of electroenzymatic syntheses with oxidoreductases, structured by the enzyme subclass and their usage of cofactors for electron relay. Particular attention is given to the productivity of electroenzymatic biotransformation processes. Because most electroenzymatic syntheses suffer from low productivity, we discuss reaction engineering concepts to overcome the main limiting factors, with a focus on media conductivity optimization, approaches to prevent enzyme inactivation, and the application of advanced cell designs. Graphical Abstract.
Collapse
Affiliation(s)
- Lisa Marie Schmitz
- Department of Biochemical and Chemical Engineering, TU Dortmund University, Dortmund, Germany
| | - Katrin Rosenthal
- Department of Biochemical and Chemical Engineering, TU Dortmund University, Dortmund, Germany
| | - Stephan Lütz
- Department of Biochemical and Chemical Engineering, TU Dortmund University, Dortmund, Germany.
| |
Collapse
|
83
|
A simple and flexible enzymatic glucose biosensor using chitosan entrapped mesoporous carbon nanocomposite. Microchem J 2019. [DOI: 10.1016/j.microc.2019.03.083] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
84
|
Facile one-step fabrication of glucose oxidase loaded polymeric nanoparticles decorating MWCNTs for constructing glucose biosensing platform: Structure matters. Biosens Bioelectron 2019; 135:153-159. [PMID: 31005767 DOI: 10.1016/j.bios.2019.04.017] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Revised: 03/26/2019] [Accepted: 04/09/2019] [Indexed: 11/21/2022]
Abstract
A novel and robust enzymatic biosensing platform with high sensitivity is developed based on facile one-step assembled bio-nanocomposites with enzymes-loaded polymeric nanoparticles decorating multi-walled carbon nanotubes (MWCNTs). An amphiphilic copolymer PAVE containing photo-cross-linkable coumarin segments and carboxylic groups was co-assembled with MWCNTs in aqueous solution while encapsulating the model enzyme namely glucose oxidase (GOx) simultaneously, generating necklace-like bio-nanocomposites (GOx@PAVE-CNTs) with GOx-loading polymeric nanoparticles as nanobeads and MWCNTs as conducting micron-string. Then the GOx@PAVE-CNTs bio-nanocomposites were electro-deposited onto electrode surface and a robust biosensing complex film with porous network structure was formed after following photo-cross-linking. Consequently, an enzymatic glucose biosensor was successfully constructed. The biosensor exhibited ultrafast response (<3 s) to glucose with a considerably wide linear range (1.0 μM ∼ 5 mM) and a low detection limit (0.36 μM) for glucose detection. High sensitivity and selectivity of the biosensor toward glucose were also well demonstrated. Furthermore, the biosensor showed exceptionally good stability and reproducibility. More importantly, the glucose biosensor was practically used for glucose detection from human urine and serum samples with satisfactory results. As a proof-of-concept strategy, this facile and effective strategy for biosensor fabrication is of considerable interest because of its versatility to be generalized to many other enzymatic biosensor systems, exhibiting promising and practical potential in bio-medical and life health applications.
Collapse
|
85
|
Research Progress on Conducting Polymer-Based Biomedical Applications. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9061070] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Conducting polymers (CPs) have attracted significant attention in a variety of research fields, particularly in biomedical engineering, because of the ease in controlling their morphology, their high chemical and environmental stability, and their biocompatibility, as well as their unique optical and electrical properties. In particular, the electrical properties of CPs can be simply tuned over the full range from insulator to metal via a doping process, such as chemical, electrochemical, charge injection, and photo-doping. Over the past few decades, remarkable progress has been made in biomedical research including biosensors, tissue engineering, artificial muscles, and drug delivery, as CPs have been utilized as a key component in these fields. In this article, we review CPs from the perspective of biomedical engineering. Specifically, representative biomedical applications of CPs are briefly summarized: biosensors, tissue engineering, artificial muscles, and drug delivery. The motivation for use of and the main function of CPs in these fields above are discussed. Finally, we highlight the technical and scientific challenges regarding electrical conductivity, biodegradability, hydrophilicity, and the loading capacity of biomolecules that are faced by CPs for future work. This is followed by several strategies to overcome these drawbacks.
Collapse
|
86
|
Pundir CS, Yadav N, Chhillar AK. Occurrence, synthesis, toxicity and detection methods for acrylamide determination in processed foods with special reference to biosensors: A review. Trends Food Sci Technol 2019. [DOI: 10.1016/j.tifs.2019.01.003] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
87
|
Nguyen HH, Lee SH, Lee UJ, Fermin CD, Kim M. Immobilized Enzymes in Biosensor Applications. MATERIALS (BASEL, SWITZERLAND) 2019; 12:E121. [PMID: 30609693 PMCID: PMC6337536 DOI: 10.3390/ma12010121] [Citation(s) in RCA: 219] [Impact Index Per Article: 36.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/22/2018] [Revised: 12/15/2018] [Accepted: 12/24/2018] [Indexed: 11/17/2022]
Abstract
Enzyme-based biosensing devices have been extensively developed over the last few decades, and have proven to be innovative techniques in the qualitative and quantitative analysis of a variety of target substrates over a wide range of applications. Distinct advantages that enzyme-based biosensors provide, such as high sensitivity and specificity, portability, cost-effectiveness, and the possibilities for miniaturization and point-of-care diagnostic testing make them more and more attractive for research focused on clinical analysis, food safety control, or disease monitoring purposes. Therefore, this review article investigates the operating principle of enzymatic biosensors utilizing electrochemical, optical, thermistor, and piezoelectric measurement techniques and their applications in the literature, as well as approaches in improving the use of enzymes for biosensors.
Collapse
Affiliation(s)
- Hoang Hiep Nguyen
- BioNanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), 125 Gwahangno, Yuseong-Gu, Daejeon 34141, Korea.
- Department of Nanobiotechnology, KRIBB School of Biotechnology, Korea University of Science and Technology (UST), 217 Gajeongno, Yuseong-Gu, Daejeon 34113, Korea.
| | - Sun Hyeok Lee
- BioNanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), 125 Gwahangno, Yuseong-Gu, Daejeon 34141, Korea.
- Department of Nanobiotechnology, KRIBB School of Biotechnology, Korea University of Science and Technology (UST), 217 Gajeongno, Yuseong-Gu, Daejeon 34113, Korea.
| | - Ui Jin Lee
- BioNanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), 125 Gwahangno, Yuseong-Gu, Daejeon 34141, Korea.
- Department of Biochemistry, College of Natural Sciences, Chungnam National University, 99 Daehangno, Yuseong-Gu, Daejeon 34134, Korea.
| | - Cesar D Fermin
- Department of Biology, College of Arts & Sciences, Tuskegee University, Tuskegee, AL 36830, USA.
| | - Moonil Kim
- BioNanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), 125 Gwahangno, Yuseong-Gu, Daejeon 34141, Korea.
- Department of Nanobiotechnology, KRIBB School of Biotechnology, Korea University of Science and Technology (UST), 217 Gajeongno, Yuseong-Gu, Daejeon 34113, Korea.
- Department of Biology, College of Arts & Sciences, Tuskegee University, Tuskegee, AL 36830, USA.
| |
Collapse
|
88
|
Parnianchi F, Nazari M, Maleki J, Mohebi M. Combination of graphene and graphene oxide with metal and metal oxide nanoparticles in fabrication of electrochemical enzymatic biosensors. INTERNATIONAL NANO LETTERS 2018. [DOI: 10.1007/s40089-018-0253-3] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
89
|
Takimoto D, Tsujimura S. Oxygen Reduction Reaction Activity and Stability of Electrochemically Deposited Bilirubin Oxidase. CHEM LETT 2018. [DOI: 10.1246/cl.180597] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Daisuke Takimoto
- Division of Materials Science, Faculty of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
- Center for Energy and Environmental of Science, Shinshu University, 3-15-1 Tokida, Ueda, Nagano 386-8567, Japan
| | - Seiya Tsujimura
- Division of Materials Science, Faculty of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| |
Collapse
|
90
|
Ngashangva L, Bachu V, Goswami P. Development of new methods for determination of bilirubin. J Pharm Biomed Anal 2018; 162:272-285. [PMID: 30273817 DOI: 10.1016/j.jpba.2018.09.034] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2018] [Revised: 09/11/2018] [Accepted: 09/16/2018] [Indexed: 02/06/2023]
Abstract
The ever-increasing demand for a sensitive, rapid and reliable method for determination of serum bilirubin level has been inciting the interest of the researchers to develop new methods for both laboratory set up and point of care applications. These efforts embrace measurement of different forms of bilirubin, such as, unconjugated (free and albumin bound) bilirubin, conjugated (direct) bilirubin, and total (both conjugated and unconjugated) bilirubin in the serum that may provide critical information useful for diagnosis of many diseases and metabolic disorders. Herein, an effort has been made to provide a broad overview on the subject starting from the conventional spectroscopy based analytical methods widely practiced in the laboratory setup along with the sophisticated instrument based sensitive methods suitable for determination of different forms of bilirubin to various portable low cost systems applicable in point of care (POC) settings. In all these discussions emphasis is given on the novel methods and techniques bearing potential to measure the bilirubin level in biological samples reliably with less technical complexity and cost. We expect that this review will serve as a ready reference for the researchers and clinical professionals working on the subject and allied fields.
Collapse
Affiliation(s)
- Lightson Ngashangva
- Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati, Assam, 781039, India
| | - Vinay Bachu
- Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati, Assam, 781039, India
| | - Pranab Goswami
- Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati, Assam, 781039, India.
| |
Collapse
|
91
|
Yamaguchi H, Tatsumi M, Takahashi K, Tagami U, Sugiki M, Kashiwagi T, Kameya M, Okazaki S, Mizukoshi T, Asano Y. Protein engineering for improving the thermostability of tryptophan oxidase and insights from structural analysis. J Biochem 2018; 164:359-367. [DOI: 10.1093/jb/mvy065] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2018] [Accepted: 07/23/2018] [Indexed: 11/15/2022] Open
Affiliation(s)
- Hiroki Yamaguchi
- Fundamental Technology Labs., Institute for Innovation, Ajinomoto Co., Inc., Kawasaki, Japan
| | - Moemi Tatsumi
- Fundamental Technology Labs., Institute for Innovation, Ajinomoto Co., Inc., Kawasaki, Japan
| | - Kazutoshi Takahashi
- Fundamental Technology Labs., Institute for Innovation, Ajinomoto Co., Inc., Kawasaki, Japan
| | - Uno Tagami
- Fundamental Technology Labs., Institute for Innovation, Ajinomoto Co., Inc., Kawasaki, Japan
| | - Masayuki Sugiki
- Fundamental Technology Labs., Institute for Innovation, Ajinomoto Co., Inc., Kawasaki, Japan
| | - Tatsuki Kashiwagi
- Fundamental Technology Labs., Institute for Innovation, Ajinomoto Co., Inc., Kawasaki, Japan
| | - Masafumi Kameya
- Biotechnology Research Center and Department of Biotechnology, Toyama Prefectural University, Imizu, Japan
- Asano Active Enzyme Molecule Project, ERATO, JST, 5180 Kurokawa, Imizu, Toyama, Japan
- Department of Biotechnology, The University of Tokyo, Yayoi 1-1-1, Bunkyo-ku, Tokyo, Japan
| | - Seiji Okazaki
- Biotechnology Research Center and Department of Biotechnology, Toyama Prefectural University, Imizu, Japan
- Asano Active Enzyme Molecule Project, ERATO, JST, 5180 Kurokawa, Imizu, Toyama, Japan
| | - Toshimi Mizukoshi
- Fundamental Technology Labs., Institute for Innovation, Ajinomoto Co., Inc., Kawasaki, Japan
| | - Yasuhisa Asano
- Biotechnology Research Center and Department of Biotechnology, Toyama Prefectural University, Imizu, Japan
- Asano Active Enzyme Molecule Project, ERATO, JST, 5180 Kurokawa, Imizu, Toyama, Japan
| |
Collapse
|
92
|
Enhanced direct electron transfer of redox protein based on multiporous SnO2 nanofiber-carbon nanotube nanocomposite and its application in biosensing. Int J Biol Macromol 2018; 114:1071-1076. [DOI: 10.1016/j.ijbiomac.2018.03.184] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Revised: 03/30/2018] [Accepted: 03/31/2018] [Indexed: 11/18/2022]
|
93
|
Eguílaz M, Villalonga R, Rivas G. Electrochemical biointerfaces based on carbon nanotubes-mesoporous silica hybrid material: Bioelectrocatalysis of hemoglobin and biosensing applications. Biosens Bioelectron 2018; 111:144-151. [DOI: 10.1016/j.bios.2018.04.004] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Revised: 03/29/2018] [Accepted: 04/03/2018] [Indexed: 01/06/2023]
|
94
|
There is no evidence to support literature claims of direct electron transfer (DET) for native glucose oxidase (GOx) at carbon nanotubes or graphene. J Electroanal Chem (Lausanne) 2018. [DOI: 10.1016/j.jelechem.2017.06.021] [Citation(s) in RCA: 111] [Impact Index Per Article: 15.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
95
|
Development of a glucose sensor employing quick and easy modification method with mediator for altering electron acceptor preference. Bioelectrochemistry 2018; 121:185-190. [DOI: 10.1016/j.bioelechem.2018.02.001] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2017] [Revised: 02/05/2018] [Accepted: 02/07/2018] [Indexed: 11/19/2022]
|
96
|
Mathematical model for the electrochemical impedance response of a continuous glucose monitor. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2018.04.103] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
97
|
Monteiro T, Almeida MG. Electrochemical Enzyme Biosensors Revisited: Old Solutions for New Problems. Crit Rev Anal Chem 2018; 49:44-66. [PMID: 29757683 DOI: 10.1080/10408347.2018.1461552] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
Worldwide legislation is driving the development of novel and highly efficient analytical tools for assessing the composition of every material that interacts with Consumers or Nature. The biosensor technology is one of the most active R&D domains of Analytical Sciences focused on the challenge of taking analytical chemistry to the field. Electrochemical biosensors based on redox enzymes, in particular, are highly appealing due to their usual quick response, high selectivity and sensitivity, low cost and portable dimensions. This review paper aims to provide an overview of the most important advances made in the field since the proposal of the first biosensor, the well-known hand-held glucose meter. The first section addresses the current needs and challenges for novel analytical tools, followed by a brief description of the different components and configurations of biosensing devices, and the fundamentals of enzyme kinetics and amperometry. The following sections emphasize on enzyme-based amperometric biosensors and the different stages of their development.
Collapse
Affiliation(s)
- Tiago Monteiro
- a UCIBIO-REQUIMTE, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa , Caparica , Portugal
| | | |
Collapse
|
98
|
Dong S, Peng L, Wei W, Huang T. Three MOF-Templated Carbon Nanocomposites for Potential Platforms of Enzyme Immobilization with Improved Electrochemical Performance. ACS APPLIED MATERIALS & INTERFACES 2018; 10:14665-14672. [PMID: 29620852 DOI: 10.1021/acsami.8b00702] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
An efficient and facile metal-organic framework (MOF)-template strategy for preparing carbon nanocomposites has been developed. First of all, a series of metal ions, including Fe3+, Zr4+, and La3+, were respectively connected with 2-aminoterephthalate (H2ATA) to form three metal-organic frameworks (MOFs) and then three novel MOF-derived materials were obtained by annealing them at 550 °C under N2 atmosphere. The morphologies and microstructure results showed that they still retained the original structure of MOFs and formed carbon-supported metal oxide hybrid nanomaterials. Interestingly, it was found that La-MOF-NH2 and its derived materials were first reported, which had wool-ball-like structure formed by many streaky-shaped particles intertwining each other. Furthermore, these MOF-derived materials were all successfully used as effective immobilization matrixes of acetylcholinesterase (AChE) to construct biosensors for the detection of methyl parathion. Especially, [La-MOF-NH2]N2 with wool-ball-like structure not only provided more active sites of multicontents to increase AChE immobilization amount but also facilitated the accessibility of electron transfer and shorten their diffusion length on the surface of electrode. Under optimal conditions, the biosensor based on [La-MOF-NH2]N2 displayed the widest linear range of 1.0 × 10-13-5.0 × 10-9 g mL-1 and the lowest detection limit of 5.8 × 10-14 g mL-1 in three biosensors. This study illustrates the feasibility and the potential of a series of MOF-derived materials for biosensors with improved electrochemical performance.
Collapse
Affiliation(s)
| | - Lei Peng
- Institute of Environmental and Food Safety , Wuhan Academy of Agricultural Science and Technology , Wuhan 430207 , People's Republic of China
| | | | | |
Collapse
|
99
|
Hooda V, Gahlaut A, Gothwal A, Hooda V. Recent trends and perspectives in enzyme based biosensor development for the screening of triglycerides: a comprehensive review. ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY 2018; 46:626-635. [DOI: 10.1080/21691401.2018.1465946] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Affiliation(s)
- Vinita Hooda
- Centre for Biotechnology, Maharshi Dayanand University, Rohtak, Haryana, India
| | | | - Ashish Gothwal
- Centre for Biotechnology, Maharshi Dayanand University, Rohtak, Haryana, India
| | - Vikas Hooda
- Centre for Biotechnology, Maharshi Dayanand University, Rohtak, Haryana, India
| |
Collapse
|
100
|
Bollella P, Gorton L, Antiochia R. Direct Electron Transfer of Dehydrogenases for Development of 3rd Generation Biosensors and Enzymatic Fuel Cells. SENSORS (BASEL, SWITZERLAND) 2018; 18:E1319. [PMID: 29695133 PMCID: PMC5982196 DOI: 10.3390/s18051319] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/07/2018] [Revised: 04/16/2018] [Accepted: 04/19/2018] [Indexed: 01/04/2023]
Abstract
Dehydrogenase based bioelectrocatalysis has been increasingly exploited in recent years in order to develop new bioelectrochemical devices, such as biosensors and biofuel cells, with improved performances. In some cases, dehydrogeases are able to directly exchange electrons with an appropriately designed electrode surface, without the need for an added redox mediator, allowing bioelectrocatalysis based on a direct electron transfer process. In this review we briefly describe the electron transfer mechanism of dehydrogenase enzymes and some of the characteristics required for bioelectrocatalysis reactions via a direct electron transfer mechanism. Special attention is given to cellobiose dehydrogenase and fructose dehydrogenase, which showed efficient direct electron transfer reactions. An overview of the most recent biosensors and biofuel cells based on the two dehydrogenases will be presented. The various strategies to prepare modified electrodes in order to improve the electron transfer properties of the device will be carefully investigated and all analytical parameters will be presented, discussed and compared.
Collapse
Affiliation(s)
- Paolo Bollella
- Department of Chemistry and Drug Technologies, Sapienza University of Rome P.le Aldo Moro 5, 00185 Rome, Italy.
| | - Lo Gorton
- Department of Biochemistry and Structural Biology, Lund University, P.O. Box 124, 221 00 Lund, Sweden.
| | - Riccarda Antiochia
- Department of Chemistry and Drug Technologies, Sapienza University of Rome P.le Aldo Moro 5, 00185 Rome, Italy.
| |
Collapse
|