51
|
Untargeted Exometabolomics Provides a Powerful Approach to Investigate Biogeochemical Hotspots with Vegetation and Polygon Type in Arctic Tundra Soils. SOIL SYSTEMS 2021. [DOI: 10.3390/soilsystems5010010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Rising temperatures in the Arctic have led to the thawing of tundra soils, which is rapidly changing terrain, hydrology, and plant and microbial communities, causing hotspots of biogeochemical activity across the landscape. Despite this, little is known about how nutrient-rich low molecular weight dissolved organic matter (LMW DOM) varies within and across tundra ecosystems. Using a high-resolution nano-liquid chromatography-mass spectrometry (LC/MS) approach, we characterized the composition and availability of LMW DOM from high-centered polygons (HCP) and low-centered polygons (LCP) with Eriophorum angustifolium or Carex aquatilis as the dominant vegetation. Over 3000 unique features (i.e., discrete mass/charge ions) were detected; 521 were identified as differentially abundant between polygonal types and 217 were putatively annotated using high mass accuracy MS data. While polygon type was a strong predictor of LMW DOM composition and availability, vegetation and soil depth were also important drivers. Extensive evidence was found for enhanced microbial processing at the LCP sites, which were dominated by Carex plant species. We detected significant differences between polygon types with varying aboveground landscape features or properties, and hotspots of biogeochemical activity, indicating LMW DOM, as quantified by untargeted exometabolomics, provides a window into the dynamic complex interactions between landscape topography, vegetation, and organic matter cycling in Arctic polygonal tundra soils.
Collapse
|
52
|
Mishra A, Chhonker YS, Bisen AC, Prasad YD, Tulsankar SL, Chandasana H, Dey T, Verma SK, Bala V, Kanojiya S, Ghatak S, Bhatta RS. Rapid and Simultaneous Analysis of Multiple Classes of Antimicrobial Drugs by Liquid Chromatography-Tandem Mass Spectrometry and Its Application to Routine Biomedical, Food, and Soil Analyses. ACS OMEGA 2020; 5:31584-31597. [PMID: 33344811 PMCID: PMC7745213 DOI: 10.1021/acsomega.0c03863] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Accepted: 11/20/2020] [Indexed: 06/12/2023]
Abstract
Antimicrobial agents (AMAs) are widely exploited nowadays to meet the high demand for animal-derived food. It has a significant impact on the food chain whose end consumers are human beings. The burden of AMAs on humans comes from either meat or crops cultivated on soil containing high residual antibiotics, which are responsible for the global crisis of antibiotic resistance. Thus, the objective of this study was to design a selective and sensitive liquid chromatography-mass spectrometry (LC-MS)/MS-based simultaneous bioanalytical method for estimation of twenty AMAs in human plasma, raw meat, and soil samples. The selective extraction of all analytes from the above matrices was performed by the solid-phase extraction clean-up method to overcome the interferences. Analytes were separated on a Waters Symmetry Shield C18 (150 × 4.6 mm2, 5 μm) column, using an isocratic solvent system of methanol-0.5% formic acid (80:20, v/v) with 0.75 mL/min flow rate. The average extraction recoveries for all analytes in plasma were ranged from 42.0 to 94.0% with relative standard deviations (RSDs) below ±15%. All of the validation parameters are in accordance with the United State Food and Drug Administration (USFDA) guidelines. Moreover, the method was also valid for a broad plasma concentration range and can be proposed as an excellent method for routine pharmacokinetic studies, therapeutic drug monitoring, clinical analysis, and detection and quantitation of AMA remnants in raw meat as a standard quality control test for human consumption.
Collapse
Affiliation(s)
- Anjali Mishra
- Pharmaceutics
& Pharmacokinetics Division, CSIR-Central
Drug Research Institute, Lucknow 226031, India
- Academy
of Scientific & Innovative Research (AcSIR), Anusandhan Bhawan, Rafi Marg, New Delhi 110 001, India
| | - Yashpal Singh Chhonker
- Pharmaceutics
& Pharmacokinetics Division, CSIR-Central
Drug Research Institute, Lucknow 226031, India
| | - Amol Chhatrapati Bisen
- Pharmaceutics
& Pharmacokinetics Division, CSIR-Central
Drug Research Institute, Lucknow 226031, India
| | - Yarra Durga Prasad
- Pharmaceutics
& Pharmacokinetics Division, CSIR-Central
Drug Research Institute, Lucknow 226031, India
| | - Sachin Laxman Tulsankar
- Pharmaceutics
& Pharmacokinetics Division, CSIR-Central
Drug Research Institute, Lucknow 226031, India
- Academy
of Scientific & Innovative Research (AcSIR), Anusandhan Bhawan, Rafi Marg, New Delhi 110 001, India
| | - Hardik Chandasana
- Pharmaceutics
& Pharmacokinetics Division, CSIR-Central
Drug Research Institute, Lucknow 226031, India
- Academy
of Scientific & Innovative Research (AcSIR), Anusandhan Bhawan, Rafi Marg, New Delhi 110 001, India
| | - Tushar Dey
- Division
of Animal Health, ICAR Research Complex
for North Eastern Hill Region, Meghalaya 793103, India
| | - Sarvesh Kumar Verma
- Pharmaceutics
& Pharmacokinetics Division, CSIR-Central
Drug Research Institute, Lucknow 226031, India
- Jawaharlal
Nehru University, New Delhi 110001, India
| | - Veenu Bala
- Academy
of Scientific & Innovative Research (AcSIR), Anusandhan Bhawan, Rafi Marg, New Delhi 110 001, India
- Medicinal
& Process Chemistry Division, CSIR-Central
Drug Research Institute, Lucknow 226031, India
| | - Sanjeev Kanojiya
- Sophisticated
Analytical Instruments Facility, CSIR-Central
Drug Research Institute, Lucknow 226031, India
| | - Sandeep Ghatak
- Division
of Animal Health, ICAR Research Complex
for North Eastern Hill Region, Meghalaya 793103, India
| | - Rabi Sankar Bhatta
- Pharmaceutics
& Pharmacokinetics Division, CSIR-Central
Drug Research Institute, Lucknow 226031, India
| |
Collapse
|
53
|
Vaudreuil MA, Vo Duy S, Munoz G, Furtos A, Sauvé S. A framework for the analysis of polar anticancer drugs in wastewater: On-line extraction coupled to HILIC or reverse phase LC-MS/MS. Talanta 2020; 220:121407. [DOI: 10.1016/j.talanta.2020.121407] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 07/10/2020] [Accepted: 07/11/2020] [Indexed: 12/16/2022]
|
54
|
Miyamoto K, Mizuno H, Sugiyama E, Toyo'oka T, Todoroki K. Machine learning guided prediction of liquid chromatography-mass spectrometry ionization efficiency for genotoxic impurities in pharmaceutical products. J Pharm Biomed Anal 2020; 194:113781. [PMID: 33280999 DOI: 10.1016/j.jpba.2020.113781] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 11/14/2020] [Accepted: 11/16/2020] [Indexed: 10/23/2022]
Abstract
The limitation and control of genotoxic impurities (GTIs) has continued to receive attention from pharmaceutical companies and authorities for several decades. Because GTIs have the ability to damage deoxyribonucleic acid (DNA) and the potential to cause cancer, low-level quantitation is required to protect patients. A quick and easy method of determining the liquid chromatography-mass spectrometry (LC/MS) conditions for high-sensitivity analysis of GTIs may prospectively accelerate pharmaceutical development. In this study, a quantitative structure-property relationship (QSPR) model was developed for predicting the ionization efficiency of compounds using liquid-chromatography-mass spectrometry (LC/MS) parameters and molecular descriptors. Before implementing the QSPR prediction model, linear regression analysis was performed to model the relationship between the ionization efficiency and the LC/MS parameters for each compound. Comparison of the predicted peak areas with the experimentally observed peak areas showed good agreement based on the coefficient of determination (R2 > 0.96). The machine learning-based QSPR approach begins with computation of the molecular descriptors expressing the physicochemical properties of a compound, followed by a genetic algorithm-based feature selection. Linear and nonlinear regression were performed, and support vector machine (SVM) was selected as the best machine learning algorithm for the prediction. The SVM algorithm was developed and optimized using 1031 experimental data points for nine compounds, including well-known GTIs. Validation of the model by comparison of the predicted and observed relative ionization efficiencies (RIE) showed a high coefficient of determination (R2 = 0.96) and low root mean squared error value (RMSE = 0.118). Finally, this established prediction model was applied to hydrophilic interaction liquid chromatography coupled with MS for a new compound in new mobile phase compositions and new MS parameter settings. The RMSE of the predicted versus observed RIE was 0.203. This prediction accuracy was sufficient to determine the starting point of the LC/MS method development. The methodology demonstrated in this study can be used to determine the LC/MS conditions for high sensitivity analysis of GTIs.
Collapse
Affiliation(s)
- Kohei Miyamoto
- Analytical Research Laboratories, Astellas Pharma Inc., 180 Ozumi, Yaizu, Shizuoka 425-0072, Japan; Department of Analytical and Bioanalytical Chemistry, School of Pharmaceutical Sciences, University of Shizuoka, Shizuoka, Japan.
| | - Hajime Mizuno
- Department of Analytical and Bioanalytical Chemistry, School of Pharmaceutical Sciences, University of Shizuoka, Shizuoka, Japan
| | - Eiji Sugiyama
- Department of Analytical and Bioanalytical Chemistry, School of Pharmaceutical Sciences, University of Shizuoka, Shizuoka, Japan
| | - Toshimasa Toyo'oka
- Department of Analytical and Bioanalytical Chemistry, School of Pharmaceutical Sciences, University of Shizuoka, Shizuoka, Japan
| | - Kenichiro Todoroki
- Department of Analytical and Bioanalytical Chemistry, School of Pharmaceutical Sciences, University of Shizuoka, Shizuoka, Japan.
| |
Collapse
|
55
|
Jørgenrud B, Skadberg E, de Carvalho Ponce J, Furuhaugen H, Berg T. Determination of the alcohol biomarker phosphatidylethanol 16:0/18:1 and 33 compounds from eight different drug classes in whole blood by LC-MS/MS. J Pharmacol Toxicol Methods 2020; 107:106939. [PMID: 33257303 DOI: 10.1016/j.vascn.2020.106939] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 09/28/2020] [Accepted: 09/29/2020] [Indexed: 10/23/2022]
Abstract
INTRODUCTION Most bioanalytical LC-MS/MS methods are developed for determination of single drugs or classes of drugs, but a multi-compound LC-MS/MS method that can replace several methods could reduce both analysis time and costs. The aim of this study was to develop a high-throughput LC-MS/MS method for determination of the alcohol biomarker phosphatidylethanol 16:0/18:1 (PEth 16:0/18:1) and 33 other compounds from eight different drug classes in whole blood. METHODS Whole-blood samples were prepared by 96-well supported liquid extraction (SLE). Chromatographic separations were performed on a biphenyl core shell column with a mobile phase consisting of 10 mM ammonium formate, pH 3.1 and methanol. Each extract was analyzed twice by LC-MS/MS, injecting 0.4 μL and 2 μL, in order to obtain narrow and symmetrical peaks and good sensitivity for all compounds. Stable isotope-labeled internal standards were used for 31 of the 34 compounds. RESULTS A 96-well SLE reversed phase LC-MS/MS method for determination of PEth 16:0/18:1 and 33 other compounds from eight different drug classes was developed and validated. By using an organic solvent mixture of isopropanol/ methyl tert-butyl ether (1:5, v:v), all compounds, including the polar and ampholytic compounds pregabalin, gabapentin and benzoylecgonine, was extracted by 96-well SLE. DISCUSSION/CONCLUSION For the first time an LC-MS/MS method for the determination of alcohol biomarker PEth 16:0/18:1 and drugs and metabolites from several different drug classes was developed and validated. The developed LC-MS/MS method can be used for high-throughput analyses and sensitive determinations of the 34 compounds in whole blood.
Collapse
Affiliation(s)
- Benedicte Jørgenrud
- Section of Drug Abuse Research, Department of Forensic Sciences, Division of Laboratory Medicine, Oslo University Hospital, P.O. Box 4950 Nydalen, N-0424 Oslo, Norway
| | - Eline Skadberg
- Section of Drug Abuse Research, Department of Forensic Sciences, Division of Laboratory Medicine, Oslo University Hospital, P.O. Box 4950 Nydalen, N-0424 Oslo, Norway
| | - Julio de Carvalho Ponce
- Department of Preventive Medicine, School of Medicine, University of Sao Paulo, Av Dr. Arnaldo, 455, Brazil
| | - Håvard Furuhaugen
- Section of Drug Abuse Research, Department of Forensic Sciences, Division of Laboratory Medicine, Oslo University Hospital, P.O. Box 4950 Nydalen, N-0424 Oslo, Norway
| | - Thomas Berg
- Section of Drug Abuse Research, Department of Forensic Sciences, Division of Laboratory Medicine, Oslo University Hospital, P.O. Box 4950 Nydalen, N-0424 Oslo, Norway.
| |
Collapse
|
56
|
Petrarca MH, Braga PADC, Reyes FGR, Bragotto APA. Hydrophilic interaction liquid chromatography coupled to quadrupole time-of-flight mass spectrometry as a potential combination for the determination of sulfonamide residues in complex infant formula matrices. J Chromatogr A 2020; 1633:461606. [PMID: 33128969 DOI: 10.1016/j.chroma.2020.461606] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 09/30/2020] [Accepted: 10/04/2020] [Indexed: 10/23/2022]
Abstract
An accurate, sensitive and selective analytical method is proposed for sulfonamide residues analysis in infant formulas based on hydrophilic interaction liquid chromatography (HILIC) and quadrupole time-of-flight mass spectrometry in full scan mode. The sample preparation approach involves low-temperature lipid precipitation followed by dispersive solid-phase extraction with PSA and C18 sorbents, which was successfully optimized using Plackett-Burman design. In order to achieve high analytical sensitivity, the influence of HILIC conditions on sulfonamide ionization was investigated, such as the mobile phase composition, buffer concentration, and sample diluent for injection. The method performance characteristics, including linearity (range 5-120 µg kg-1), reliable limits of quantification (between 5 and 20 µg kg-1), recovery (72.9-109.2%) and precision (coefficient of variation values ≤ 19.8%) under repeatability and within-laboratory reproducibility conditions, were in accordance with the Codex Alimentarius Commission CAC/GL 71-2009 for quantitative analytical methods for veterinary drug residues in foods. Moreover, adequate identification of the compounds was provided with accurate mass measurement of both precursor and fragment ions in one single run. Finally, the developed method was applied to thirty-five powdered milk-based infant formula samples available in the Brazilian market.
Collapse
Affiliation(s)
- Mateus Henrique Petrarca
- Department of Food Science, School of Food Engineering, University of Campinas (UNICAMP), Rua Monteiro Lobato, 80, 13083-862, Campinas, SP, Brazil.
| | - Patrícia Aparecida de Campos Braga
- Department of Food Science, School of Food Engineering, University of Campinas (UNICAMP), Rua Monteiro Lobato, 80, 13083-862, Campinas, SP, Brazil
| | - Felix Guillermo Reyes Reyes
- Department of Food Science, School of Food Engineering, University of Campinas (UNICAMP), Rua Monteiro Lobato, 80, 13083-862, Campinas, SP, Brazil
| | - Adriana Pavesi Arisseto Bragotto
- Department of Food Science, School of Food Engineering, University of Campinas (UNICAMP), Rua Monteiro Lobato, 80, 13083-862, Campinas, SP, Brazil
| |
Collapse
|
57
|
Uçaktürk E, Başaran AA, Demirel AH. Effect of the Mobile Phase Compositions on the Confirmation Analysis of Some Prohibited Substances in Sport by LC–ESI–MS/MS. Chromatographia 2020. [DOI: 10.1007/s10337-020-03957-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
58
|
Hebra T, Eparvier V, Touboul D. Atmospheric pressure photoionization versus electrospray for the dereplication of highly conjugated natural products using molecular networks. J Chromatogr A 2020; 1630:461533. [PMID: 32950817 DOI: 10.1016/j.chroma.2020.461533] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 09/01/2020] [Accepted: 09/08/2020] [Indexed: 12/30/2022]
Abstract
Natural products are sources of inspiration and reservoir of high valuable molecules. Recently, analytical tools based on liquid chromatography coupled to tandem mass spectrometry to generate molecular network became widely employed for dereplication. This strategy greatly accelerates the identification of known and structural hypothesis of unknown. Despite the availability of different ionization sources, alternatives to classical electrospray ionization (ESI), such as atmospheric pressure chemical ionization (APCI) or photoionization (APPI), have been neglected. In particular, APPI has been described for its ionization efficiency on non-polar molecules bearing no acid or basic groups. For that reason, we investigated APPI potential to generate molecular network and compare it to ESI on several criteria that are generation of ion species, sensitivity and signal-to-noise ratio (SNR) for different extracts rich in highly conjugated natural products. We first optimized APPI experimental conditions on crude extract from a fungus, Penicillium sclerotiorum, producing polyketones belonging to the azaphilone family. Then we compared APPI and ESI on different fractions of the fungus and on two plant extracts, French Guyanese Swartzia panacoco (Aubl.) R.S. Cowan (arial parts) and Indian Cassia auriculata L. (leaves) containing phenolic compounds, such as flavonoids. While ESI generated more ion species and displayed a better sensitivity, APPI generated only protonated adduct and better SNR. Comparing ESI and APPI generated species on molecular network reveal that both strategies overlap for the majority of protonated ions.
Collapse
Affiliation(s)
- Teo Hebra
- Université Paris-Saclay, CNRS, Institut de Chimie des Substances Naturelles, UPR 2301, 91198, Gif-sur-Yvette, France
| | - Véronique Eparvier
- Université Paris-Saclay, CNRS, Institut de Chimie des Substances Naturelles, UPR 2301, 91198, Gif-sur-Yvette, France
| | - David Touboul
- Université Paris-Saclay, CNRS, Institut de Chimie des Substances Naturelles, UPR 2301, 91198, Gif-sur-Yvette, France.
| |
Collapse
|
59
|
Sobolevsky T, Ahrens B. High-throughput liquid chromatography tandem mass spectrometry assay as initial testing procedure for analysis of total urinary fraction. Drug Test Anal 2020; 13:283-298. [PMID: 32852861 DOI: 10.1002/dta.2917] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Revised: 08/16/2020] [Accepted: 08/17/2020] [Indexed: 12/14/2022]
Abstract
In the recent years, a lot of effort was put into the development of multiclass initial testing procedures (ITP) to streamline analytical workflow in antidoping laboratories. Here, a high-throughput assay based on liquid chromatography-triple quadrupole mass spectrometry suitable for use as initial testing procedure covering multiple classes of compounds prohibited in sports is described. Employing a 96-well plate packed with 10 mg of weak cation exchange polymeric sorbent, up to 94 urine samples and their associated positive and negative controls can be processed in less than 3 h with minimal labor. The assay requires a 0.5-ml urine aliquot, which is subjected to enzymatic hydrolysis followed by solid phase extraction, evaporation, and reconstitution in a 96-well collection plate. With a 10-min run time, more than 100 analytes can be detected using electrospray ionization with polarity switching. The assay can be run nearly 24/7 with minimal downtime for instrument maintenance while detecting picogram amounts for the majority of analytes. Having analyzed approximately 28,000 samples, nearly 400 adverse analytical findings were found of which only one tenth were at or above 50% of the minimum required performance level established by the World Anti-Doping Agency. Compounds most often identified were stanozolol, GW1516, ostarine, LGD4033, and clomiphene, with median estimated concentrations in the range of 0.02-0.09 ng/ml (either as parent drug or a metabolite). Our data demonstrate the importance of using a highly sensitive ITP to ensure efficient antidoping testing.
Collapse
Affiliation(s)
- Tim Sobolevsky
- UCLA Olympic Analytical Laboratory, Department of Pathology & Laboratory Medicine, David Geffen School of Medicine, Los Angeles, California, USA
| | - Brian Ahrens
- UCLA Olympic Analytical Laboratory, Department of Pathology & Laboratory Medicine, David Geffen School of Medicine, Los Angeles, California, USA
| |
Collapse
|
60
|
Woźniczka M, Sutradhar M, Pombeiro AJL, Świątek M, Pająk M, Gądek-Sobczyńska J, Chmiela M, Gonciarz W, Pasternak B, Kufelnicki A. Equilibria in Aqueous Cobalt(II)-Reduced Schiff Base N-(2-hydroxybenzyl)alanine System: Chemical Characterization, Kinetic Analysis, Antimicrobial and Cytotoxic Properties. Molecules 2020; 25:molecules25153462. [PMID: 32751474 PMCID: PMC7436002 DOI: 10.3390/molecules25153462] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 07/27/2020] [Accepted: 07/28/2020] [Indexed: 11/16/2022] Open
Abstract
The present study describes the coordination properties of a reduced Schiff base, N-(2-hydroxybenzyl)alanine, towards cobalt(II) using potentiometric as well as spectroscopic (UV-Vis and ESI-MS) methods. The results indicate the formation of six mononuclear complexes showing high stability in aqueous solution. Coordination occurs in the {O−phenolic,N,O−carboxyl} and {N,O−carboxyl} chelation modes, depending on the degree of ligand deprotonation. Examination of the complexation equilibria at pH ca 7, which is important from a biological point of view, allowed to identify two species: [CoL] and [CoL2H]−. The kinetic analysis showed a structural change of those cobalt(II) complexes from octahedral to tetrahedral in accordance with a first-order time relationship. The antimicrobial properties of N-(2-hydroxybenzyl)alanine, cobalt(II) nitrate and of the Co(II) – ligand complexes were determined against Gram-positive bacteria (Enterococcus faecalis, Staphylococcus aureus, Staphylococcus epidermidis), Gram-negative bacteria (Pseudomonas aeruginosa, Escherichia coli, Helicobacter pylori) and a fungal strain (Candida). The results indicate that the complexes are more active for more strains than the ligand alone. Nevertheless, the complexes induce a higher decrease in the metabolic activity of cells but without damage to nuclei. Tetrahedral structures show stronger anti-cellular toxicity than octahedral complexes, which is most likely due to the higher accessibility of the cobalt(II) center.
Collapse
Affiliation(s)
- Magdalena Woźniczka
- Department of Physical and Biocoordination Chemistry, Faculty of Pharmacy, Medical University of Lodz, Muszyńskiego 1, 90-151 Lodz, Poland; (M.Ś.); (M.P.); (J.G.-S.); (A.K.)
- Correspondence:
| | - Manas Sutradhar
- Centro de Química Estrutural, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal; (M.S.); (A.J.L.P.)
| | - Armando J. L. Pombeiro
- Centro de Química Estrutural, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal; (M.S.); (A.J.L.P.)
| | - Mirosława Świątek
- Department of Physical and Biocoordination Chemistry, Faculty of Pharmacy, Medical University of Lodz, Muszyńskiego 1, 90-151 Lodz, Poland; (M.Ś.); (M.P.); (J.G.-S.); (A.K.)
| | - Marek Pająk
- Department of Physical and Biocoordination Chemistry, Faculty of Pharmacy, Medical University of Lodz, Muszyńskiego 1, 90-151 Lodz, Poland; (M.Ś.); (M.P.); (J.G.-S.); (A.K.)
| | - Joanna Gądek-Sobczyńska
- Department of Physical and Biocoordination Chemistry, Faculty of Pharmacy, Medical University of Lodz, Muszyńskiego 1, 90-151 Lodz, Poland; (M.Ś.); (M.P.); (J.G.-S.); (A.K.)
| | - Magdalena Chmiela
- Department of Immunology and Infectious Biology, Institute of Microbiology, Biotechnology and Immunology, Faculty of Biology and Environmental Protection, University of Lodz, Banacha 12/16, 90-237 Lodz, Poland; (M.C.); (W.G.)
| | - Weronika Gonciarz
- Department of Immunology and Infectious Biology, Institute of Microbiology, Biotechnology and Immunology, Faculty of Biology and Environmental Protection, University of Lodz, Banacha 12/16, 90-237 Lodz, Poland; (M.C.); (W.G.)
| | - Beata Pasternak
- Department of Organic Chemistry, Faculty of Chemistry, University of Lodz, Tamka 12, 91-403 Lodz, Poland;
| | - Aleksander Kufelnicki
- Department of Physical and Biocoordination Chemistry, Faculty of Pharmacy, Medical University of Lodz, Muszyńskiego 1, 90-151 Lodz, Poland; (M.Ś.); (M.P.); (J.G.-S.); (A.K.)
| |
Collapse
|
61
|
Gachumi G, Purves RW, Hopf C, El-Aneed A. Fast Quantification Without Conventional Chromatography, The Growing Power of Mass Spectrometry. Anal Chem 2020; 92:8628-8637. [PMID: 32510944 DOI: 10.1021/acs.analchem.0c00877] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Mass spectrometry (MS) in hyphenated techniques is widely accepted as the gold standard quantitative tool in life sciences. However, MS possesses intrinsic analytical capabilities that allow it to be a stand-alone quantitative technique, particularly with current technological advancements. MS has a great potential for simplifying quantitative analysis without the need for tedious chromatographic separation. Its selectivity relies on multistage MS analysis (MSn), including tandem mass spectrometry (MS/MS), as well as the ever-growing advancements of high-resolution MS instruments. This perspective describes various analytical platforms that utilize MS as a stand-alone quantitative technique, namely, flow injection analysis (FIA), matrix assisted laser desorption ionization (MALDI), including MALDI-MS imaging and ion mobility, particularly high-field asymmetric waveform ion mobility spectrometry (FAIMS). When MS alone is not capable of providing reliable quantitative data, instead of conventional liquid chromatography (LC)-MS, the use of a guard column (i.e., fast chromatography) may be sufficient for quantification. Although the omission of chromatographic separation simplifies the analytical process, extra procedures may be needed during sample preparation and clean-up to address the issue of matrix effects. The discussion of this manuscript focuses on key parameters underlying the uniqueness of each technique for its application in quantitative analysis without the need for a chromatographic separation. In addition, the potential for each analytical strategy and its challenges are discussed as well as improvements needed to render them as mainstream quantitative analytical tools. Overcoming the hurdles for fully validating a quantitative method will allow MS alone to eventually become an indispensable quantitative tool for clinical and toxicological studies.
Collapse
Affiliation(s)
- George Gachumi
- College of Pharmacy and Nutrition, University of Saskatchewan, 107 Wiggins Road, Saskatoon, Saskatchewan Canada, S7N 5E5
| | - Randy W Purves
- College of Pharmacy and Nutrition, University of Saskatchewan, 107 Wiggins Road, Saskatoon, Saskatchewan Canada, S7N 5E5.,Centre for Veterinary Drug Residues, Canadian Food Inspection Agency, 116 Veterinary Rd, Saskatoon, Saskatchewan Canada, S7N 2R3
| | - Carsten Hopf
- Center for Mass Spectrometry and Optical Spectroscopy (CeMOS), Mannheim University of Applied Sciences, Paul-Wittsack-Strasse 10, 68163 Mannheim, Germany
| | - Anas El-Aneed
- College of Pharmacy and Nutrition, University of Saskatchewan, 107 Wiggins Road, Saskatoon, Saskatchewan Canada, S7N 5E5
| |
Collapse
|
62
|
Long F, Zhang M, Yuan J, Du J, Ma A, Pan J. A simple, versatile, and automated pulse-diffusion-focusing strategy for sensitive milliliter-level-injection HILIC-MS/MS analysis of hydrophilic toxins. JOURNAL OF HAZARDOUS MATERIALS 2020; 392:122318. [PMID: 32092652 DOI: 10.1016/j.jhazmat.2020.122318] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Revised: 01/16/2020] [Accepted: 02/14/2020] [Indexed: 06/10/2023]
Abstract
The measurement of trace hydrophilic toxins in complex aqueous-rich matrices is a daunting challenge. To address this analytical bottleneck, pulse diffusion focusing (PDF), a novel sample injection technique for hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-MS/MS), was developed. Theoretical and experimental investigations of the mechanism and key parameters revealed that the pulse-injection approach, assisted by solvent diffusion, efficiently solved the volume overload problem. This milliliter-level-injection HILIC-MS/MS technique was reported for the first time herein, and provided a significant enhancement in sensitivity compared to the conventional injection method, in addition to being an efficient approach to address the solvent incompatibility of off-line sample preparation and HILIC. The automated PDF-HILIC-MS/MS system was obtained by slightly modifying a commercial LC-MS/MS instrument in an easy and economical manner. The efficiency of the system was demonstrated through the detection of trace tetrodotoxin contents in plasma and urine samples. Low limits of detection (i.e., 0.65 and 2.2 ng·mL-1) were obtained using the simplified sample preparation method. The recoveries were in the range 91-113.3 % with intra-day and inter-day precisions of ≤9.6 %. Further experimental results proved the method to be versatile for various hydrophilic toxins.
Collapse
Affiliation(s)
- Fei Long
- Department of Hygiene Detection Center, School of Public Health, Southern Medical University (Guangdong Provincial Key Laboratory of Tropical Disease Research), Guangzhou, Guangdong, China
| | - Mei Zhang
- Department of Hygiene Detection Center, School of Public Health, Southern Medical University (Guangdong Provincial Key Laboratory of Tropical Disease Research), Guangzhou, Guangdong, China
| | - Jiahao Yuan
- Department of Hygiene Detection Center, School of Public Health, Southern Medical University (Guangdong Provincial Key Laboratory of Tropical Disease Research), Guangzhou, Guangdong, China
| | - Juan Du
- Department of Hygiene Detection Center, School of Public Health, Southern Medical University (Guangdong Provincial Key Laboratory of Tropical Disease Research), Guangzhou, Guangdong, China
| | - Ande Ma
- Department of Hygiene Detection Center, School of Public Health, Southern Medical University (Guangdong Provincial Key Laboratory of Tropical Disease Research), Guangzhou, Guangdong, China.
| | - Jialiang Pan
- Department of Hygiene Detection Center, School of Public Health, Southern Medical University (Guangdong Provincial Key Laboratory of Tropical Disease Research), Guangzhou, Guangdong, China.
| |
Collapse
|
63
|
Gornischeff A, Kruve A, Rebane R. Characterization of wines with liquid chromatography electrospray ionization mass spectrometry: Quantification of amino acids via ionization efficiency values. J Chromatogr A 2020; 1620:461012. [PMID: 32276856 DOI: 10.1016/j.chroma.2020.461012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 03/04/2020] [Accepted: 03/05/2020] [Indexed: 11/29/2022]
Abstract
Quantification of analysis results for the suspect and non-targeted screening is essential for obtaining meaningful insight from the measurements. Ionization efficiency predictions is a possible approach to enable quantitation without standard substances. This is, however, especially challenging for the analysis carried out by combining the full scan mode either with fragmentation experiments in data-dependent or data-independent acquisition mode. Here we investigate the correlation of ionization efficiency values measured in full scan mode with the response factors measured in multiple reaction monitoring (MRM) mode for derivatized amino acids. We observe good correlation (R2 of 0.80) for 6-Aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) derivatized amino acids. This encourages the use of the measured ionization efficiency values to estimate amino acid concentrations in different beverages. We apply the measured ionization efficiency values for estimating the concentration of amino acids for measurements done both in full scan as well as in MRM mode in wines and beers. We show that the calculated concentrations are in very good correlation with measured values (R2 of 0.71 to 1.00). The method possesses average trueness of 70.5% and shows an insignificant matrix effect.
Collapse
Affiliation(s)
- Artur Gornischeff
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411 Tartu, Estonia
| | - Anneli Kruve
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411 Tartu, Estonia; Department of Environmental Science and Analytical Chemistry, Stockholm University, Svante Arrhenius väg 16, 106 91 Stockholm, Sweden.
| | - Riin Rebane
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411 Tartu, Estonia
| |
Collapse
|
64
|
Salvador A, Carrière R, Ayciriex S, Margoum C, Leblanc Y, Lemoine J. Scout-multiple reaction monitoring: A liquid chromatography tandem mass spectrometry approach for multi-residue pesticide analysis without time scheduling. J Chromatogr A 2020; 1621:461046. [DOI: 10.1016/j.chroma.2020.461046] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Revised: 01/15/2020] [Accepted: 03/12/2020] [Indexed: 11/24/2022]
|
65
|
Strmeň T, Vrkoslav V, Bosáková Z, Cvačka J. Atmospheric pressure chemical ionization mass spectrometry at low flow rates: Importance of ion source housing. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34:e8722. [PMID: 31912928 DOI: 10.1002/rcm.8722] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 12/01/2019] [Accepted: 01/06/2020] [Indexed: 06/10/2023]
Abstract
RATIONALE Hyphenation of atmospheric pressure chemical ionization (APCI) mass spectrometry with capillary and micro high-performance liquid chromatography (HPLC) is attractive for many applications, but reliable ion sources dedicated to these conditions are still missing. There are a number of aspects to consider when designing such an ion source, including the susceptibility of the ionization processes to ambient conditions. Here we discuss the importance of ion source housing for APCI at low flow rates. METHODS Selected compounds dissolved in various solvents were used to study ionization reactions at 10 μL/min flow rate. APCI spectra were generated using the Ion Max-S source (Thermo Fisher Scientific) operated with or without the ion source housing. RESULTS The APCI spectra of most compounds measured in the open and enclosed ion sources were markedly different. The differences were explained by water and oxygen molecules that entered the plasma region of the open ion source. Water tended to suppress charge transfer processes while oxygen diminished electron capture reactions and prevented the formation of acetonitrile-related radical cations useful for localizing double bonds in lipids. The effects associated with the ion source housing were significantly less important for compounds that are easy to protonate or deprotonate. CONCLUSIONS The use of ion source housing prevented alternative ionization channels leading to unwanted or unexpected ions. Compared with the conventional flow rate mode (1 mL/min), the effects of ambient air components were significantly higher at 10 μL/min, emphasizing the need for ion source housing in APCI sources dedicated to low flow rates.
Collapse
Affiliation(s)
- Timotej Strmeň
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, CZ-166 10, Prague 6, Czech Republic
- Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 43, Prague 2, Czech Republic
| | - Vladimír Vrkoslav
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, CZ-166 10, Prague 6, Czech Republic
| | - Zuzana Bosáková
- Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 43, Prague 2, Czech Republic
| | - Josef Cvačka
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, CZ-166 10, Prague 6, Czech Republic
- Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 43, Prague 2, Czech Republic
| |
Collapse
|
66
|
Simultaneous Analysis of Fenthion and Its Five Metabolites in Produce Using Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry. Molecules 2020; 25:molecules25081938. [PMID: 32331373 PMCID: PMC7221716 DOI: 10.3390/molecules25081938] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Revised: 04/17/2020] [Accepted: 04/20/2020] [Indexed: 11/16/2022] Open
Abstract
A simultaneous analytical method for the organophosphorus insecticide fenthion and its five metabolites (fenthion oxon, fenthion oxon sulfoxide, fenthion oxon sulfone, fenthion sulfoxide, and fenthion sulfone) was developed based on ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Five matrices (brown rice, chili pepper, orange, potato, and soybean) were selected to validate the method. The target compounds were analyzed using positive electrospray ionization in the multiple reaction monitoring mode. For the best sensitivity in regard to the detector response, water and methanol containing formic acid (0.1%) were selected as the mobile phase. The optimum extraction efficiency was obtained through a citrate-buffered QuEChERS (quick, easy, cheap, effective, rugged, and safe) method. Recovery tests were carried out at three spiking levels (n = 3). At all fortification levels, the accuracy and precision results were between 70% and 120% with a relative standard deviation of ≤15%. The limit of quantitation was 0.01 mg/kg, and the correlation coefficients (r2) of the matrix-matched calibration curves were >0.99. Significant signal suppression in the detector responses were observed for all matrices, suggesting that a compensation method, such as matrix-matched calibration, is required to provide accurate quantitative results. The applicability of the presented method was confirmed for the simultaneous analysis of fenthion and its metabolites in various crops.
Collapse
|
67
|
Application of hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry for the retention and sensitivity studies of antisense oligonucleotides. J Chromatogr A 2020; 1622:461100. [PMID: 32359780 DOI: 10.1016/j.chroma.2020.461100] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Revised: 03/30/2020] [Accepted: 03/31/2020] [Indexed: 11/20/2022]
Abstract
The aim of the present investigation was application of hydrophilic interaction liquid chromatography as an alternative chromatographic approach for the study of antisense oligonucleotides. The influence of several mobile phases, differing with the salt type, their concentration and pH value on the retention and the separation of antisense oligonucleotides has been examined for this purpose. Four different stationary phases were also applied including unmodified silica, silica modified with the use of sulfobetaine groups, polyhydroxy and aminopropyl groups. Such wide range of tested conditions has been useful in better understanding of the retention mechanism of tested compounds. The results obtained during this investigation indicated that greater retention, greater peaks symmetry, as well as more effective separation of oligonucleotides, were obtained for the zwitterionic stationary phase. Moreover, the optimization of tandem mass spectrometry parameters with the use of Central Composite Design was performed and different mobile phases were tested to choose that one, which provided the greatest antisense oligonucleotides peak areas in Multiple Reaction Monitoring mode and consequently, the greatest possible sensitivity. Hydrophilic interaction liquid chromatography was compared with the ion pair chromatography, commonly used in the analysis of oligonucleotides. Both techniques were compared in terms of selectivity of separation as well as the sensitivity of their determination. Obtained results proved that ion pair chromatography provided better results in terms of separation efficiency and peak areas in Multiple Reaction Monitoring for tested conditions. However, these results do not preclude application of hydrophilic interaction liquid chromatography as an alternative chromatographic approach for the oligonucleotides analysis especially when a mobile phase without ion pair reagents is required.
Collapse
|
68
|
Härdelin L, Bernin D, Börjesson M, Ström A, Larsson A. Altered Thermal and Mechanical Properties of Spruce Galactoglucomannan Films Modified with an Etherification Reaction. Biomacromolecules 2020; 21:1832-1840. [PMID: 32068390 DOI: 10.1021/acs.biomac.9b01730] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Native hemicellulose lacks many of the properties that make fossil fuel-based polymers excellent for use in today's industrial products and processes. The mechanical and thermal properties of the hemicellulose can, however, be modified, and its processability increased. We functionalized galactoglucomannan to lower its glass transition temperature (Tg) and thereby increase its processability. The functionalization was achieved through an etherification reaction with butyl glycidyl ether used at three molar ratios. Films were produced, and their mechanical and thermal properties were evaluated. Thermogravimetric analysis showed that increased substitution increased the degradation temperature and decreased the water content in the sample, implying increased hydrophobicity upon modification. Dynamic mechanical analysis indicated that butyl glycidyl ether functionalization alters the thermal properties of the modified films both in the absolute values of Tg and in the strength of the films. The etherification reaction resulted in a more ductile material than the unmodified galactoglucomannan (GGM).
Collapse
Affiliation(s)
- Linda Härdelin
- Department of Chemistry and Chemical Engineering, Chalmers University of Technology, SE-41296 Gothenburg, Sweden
| | - Diana Bernin
- Department of Chemistry and Chemical Engineering, Chalmers University of Technology, SE-41296 Gothenburg, Sweden
| | - Mikaela Börjesson
- Department of Chemistry and Chemical Engineering, Chalmers University of Technology, SE-41296 Gothenburg, Sweden
| | - Anna Ström
- Department of Chemistry and Chemical Engineering, Chalmers University of Technology, SE-41296 Gothenburg, Sweden
| | - Anette Larsson
- Department of Chemistry and Chemical Engineering, Chalmers University of Technology, SE-41296 Gothenburg, Sweden
| |
Collapse
|
69
|
Petrov AP, Sherman LM, Camden JP, Dovichi NJ. Database of free solution mobilities for 276 metabolites. Talanta 2020; 209:120545. [PMID: 31892063 PMCID: PMC6956853 DOI: 10.1016/j.talanta.2019.120545] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2019] [Revised: 11/01/2019] [Accepted: 11/07/2019] [Indexed: 11/23/2022]
Abstract
Although databases are available that provide mass spectra and chromatographic retention information for small-molecule metabolites, no publicly available database provides electrophoretic mobility for common metabolites. As a result, most compounds found in electrophoretic-based metabolic studies are unidentified and simply annotated as "features". To begin to address this issue, we analyzed 460 metabolites from a commercial library using capillary zone electrophoresis coupled with electrospray mass spectrometry. To speed analysis, a sequential injection method was used wherein six compounds were analyzed per run. An uncoated fused silica capillary was used for the analysis at 20 °C with a 0.5% (v/v) formic acid and 5% (v/v) methanol background electrolyte. A Prince autosampler was used for sample injection and the capillary was coupled to an ion trap mass spectrometer using an electrokinetically-pumped nanospray interface. We generated mobility values for 276 metabolites from the library (60% success rate) with an average standard deviation of 0.01 × 10-8 m2V-1s-1. As expected, cationic and anionic compounds were well resolved from neutral compounds. Neutral compounds co-migrated with electro-osmotic flow. Most of the compounds that were not detected were neutral and presumably suffered from adsorption to the capillary wall or poor ionization efficiency.
Collapse
Affiliation(s)
- Alexander P Petrov
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, 46556-5670, USA
| | - Lindy M Sherman
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, 46556-5670, USA
| | - Jon P Camden
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, 46556-5670, USA
| | - Norman J Dovichi
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, 46556-5670, USA.
| |
Collapse
|
70
|
Sacdal R, Madriaga J, Espino MP. Overview of the analysis, occurrence and ecological effects of hormones in lake waters in Asia. ENVIRONMENTAL RESEARCH 2020; 182:109091. [PMID: 31927242 DOI: 10.1016/j.envres.2019.109091] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2019] [Revised: 11/15/2019] [Accepted: 12/25/2019] [Indexed: 06/10/2023]
Abstract
Hormones are natural and synthetic compounds that are now being detected in the aquatic environment. Many lakes in Asia are important water sources that may be affected by these emerging contaminants. Lakes are drains and reservoirs of watersheds that are altered by changing land use and environmental conditions. While there are several studies on the detection of hormones in lakes, these studies were mostly done in China. Limited information is available on the presence of these contaminants in the lakes in other Asian countries. Hormones in the lake water come from discharge waters in urban areas, farm runoffs, and effluents of wastewater and sewage treatment plants. Hormones contamination in water has been shown to affect the reproduction and growth of certain aquatic organisms. In this review, a background on the chemical nature and physiological functions of hormones is provided and the existing knowledge on the occurrence and ecological impacts of hormones in lakes is described. The available analytical methods for sampling, analyte extraction and instrumental analysis are outlined. This overview provides insights on the current conditions of lakes that may be impacted by hormones contamination. Understanding the levels and possible ecological consequences will address the issues on these emerging contaminants especially in the Asian environment. This will elicit discussions on improving guidelines on wastewater discharges and will drive future research directions.
Collapse
Affiliation(s)
- Rosselle Sacdal
- Institute of Chemistry, University of the Philippines Diliman, Quezon City, 1101, Philippines
| | - Jonalyn Madriaga
- Institute of Chemistry, University of the Philippines Diliman, Quezon City, 1101, Philippines
| | - Maria Pythias Espino
- Institute of Chemistry, University of the Philippines Diliman, Quezon City, 1101, Philippines.
| |
Collapse
|
71
|
Wang Q, Shimizu K, Maehata K, Pan Y, Sakurai K, Hikida T, Fukada Y, Takao T. Lithium ion adduction enables UPLC-MS/MS-based analysis of multi-class 3-hydroxyl group-containing keto-steroids. J Lipid Res 2020; 61:570-579. [PMID: 32102801 DOI: 10.1194/jlr.d119000588] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 02/20/2020] [Indexed: 01/13/2023] Open
Abstract
Steroids that contain a 3-hydroxyl group (3-OH steroids) are widely distributed in nature. During analysis with ESI-MS, they easily become dehydrated while in the protonated form, resulting in the production of several precursor ions and leading to low sensitivity of detection. To address this analytical challenge, here, we developed a method for the quantitation of 3-OH steroids by LC-MS/MS coupled with post-column addition of lithium (Li) ions to the mobile phase. The Li ion has a high affinity for the keto group of steroids, stabilizing their structures during ionization and permitting detection of analytes exclusively as the lithiated form. This not only improved the intensities of the precursor ions, but also promoted the formation of typical lithiated fragment ions. This improvement made the quantitation by multiple reaction monitoring more sensitive and reliable, as evidenced by 1.53-188 times enhanced detection sensitivity of 13 steroids that contained at least one keto and two hydroxyl groups or one keto and one 5-olefinic double bond, among 16 different 3-OH steroids. We deployed our newly developed method for profiling steroids in mouse brain tissue and identified six steroids in one tissue sample. Among these, 16-hydroxyestrone, tetrahydrocorticosterone, and 17α-hydroxypregnenolone were detected for the first time in the mouse brain. In summary, the method described here enables the detection of lithiated steroids by LC-MS/MS, including three 3-OH steroids not previously reported in the mouse brain. We anticipate that this new method may allow the determination of 3-OH steroids in different brain regions.
Collapse
Affiliation(s)
- Qiuyi Wang
- Institute for Protein Research, Osaka University, Osaka 565-0871, Japan
| | - Kimiko Shimizu
- Department of Biological Sciences, School of Science, University of Tokyo, Tokyo 113-0033, Japan
| | - Kanako Maehata
- Department of Biological Sciences, School of Science, University of Tokyo, Tokyo 113-0033, Japan
| | - Yue Pan
- Institute for Protein Research, Osaka University, Osaka 565-0871, Japan
| | - Koki Sakurai
- Institute for Protein Research, Osaka University, Osaka 565-0871, Japan
| | - Takatoshi Hikida
- Institute for Protein Research, Osaka University, Osaka 565-0871, Japan
| | - Yoshitaka Fukada
- Department of Biological Sciences, School of Science, University of Tokyo, Tokyo 113-0033, Japan
| | - Toshifumi Takao
- Institute for Protein Research, Osaka University, Osaka 565-0871, Japan
| |
Collapse
|
72
|
Chen Z, Gao Y, Zhong D. Technologies to improve the sensitivity of existing chromatographic methods used for bioanalytical studies. Biomed Chromatogr 2020; 34:e4798. [PMID: 31994210 DOI: 10.1002/bmc.4798] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Revised: 01/10/2020] [Accepted: 01/24/2020] [Indexed: 12/16/2022]
Abstract
Chromatographic method has long been recognized as the most widely used separation method in bioanalytical research. However, the relatively low sensitivity of existing chromatographic methods remains a significant challenge, as the requirements for experimental procedures become more demanding. This review discusses the main causes for the low sensitivity of chromatographic methods and aims to introduce different technologies for enhancing their sensitivity in the following aspects: (i) different pretreatment methods for improving clean-up efficiency and recovery; (ii) derivatization step for altering the chromatographic behavior of analytes and enhancing MS ionization efficiency; (iii) optimal LC-MS conditions and appropriate separation mechanism; and (iv) applications of other chromatographic methods, including miniaturized LC, 2D-LC, 2D-GC, and supercritical fluid chromatography. Altogether, this review is devoted to summarizing the recent technologies reported in the literature and providing new strategies for the detection of bioanalytes.
Collapse
Affiliation(s)
- Zhendong Chen
- State Key Laboratory of Drug Research, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai, China.,University of Chinese Academy of Sciences, Beijing, China
| | - Yuxiong Gao
- State Key Laboratory of Drug Research, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai, China.,University of Chinese Academy of Sciences, Beijing, China
| | - Dafang Zhong
- State Key Laboratory of Drug Research, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai, China.,University of Chinese Academy of Sciences, Beijing, China
| |
Collapse
|
73
|
Kafeenah HIS, Osman R, Bakar NKA. Effect of Mobile Phase pH on the Electrospray Ionization Efficiency and Qualitative Analysis of Pharmaceuticals in ESI + LC-MS/MS. J Chromatogr Sci 2020; 57:847-854. [PMID: 31512731 DOI: 10.1093/chromsci/bmz061] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Revised: 05/31/2019] [Accepted: 07/01/2019] [Indexed: 11/12/2022]
Abstract
The effect of mobile phase pH on positive ionization process and retention time of nine pharmaceuticals on ultra-performance liquid chromatography-electrospray-tandem mass spectrometry (LC-MS/MS) was discussed. The effective use of high and low mobile phase pH in LC-MS/MS qualitative analyses method was also evaluated by comparing the instrument detection limit, quantification limit, precision, linearity and signal to noise (S/N) under low and high mobile phase pH. In this work, six mobile phase pH that ranged between pH 2 and pH 10 were used to evaluate the effect of the mobile phase pH changes on the ionization process in electrospray ionization. Results revealed that high mobile phase pH ionized more pharmaceuticals molecules and gave a higher signal than low mobile phase pH in positive ionization mode. The results proved that ammonium ion was better as a proton donor in high pH mobile phase than the hydronium ion in acidic mobile phase. The results revealed that the qualitative LC-MS/MS analyses method by using high mobile phase pH has better performance for most analytes in terms of sensitivity, precision, linearity and S/N than the low mobile phase pH.
Collapse
Affiliation(s)
- Husam I S Kafeenah
- Department of Chemistry, Faculty of Science, University of Malaya, 50603 Kuala Lumpur, Malaysia
| | - Rozita Osman
- Faculty of Applied Sciences, Universiti Teknologi MARA, 40450 Shah Alam, Selangor, Malaysia
| | - N K A Bakar
- Department of Chemistry, Faculty of Science, University of Malaya, 50603 Kuala Lumpur, Malaysia
| |
Collapse
|
74
|
Xu JD, Xu MZ, Zhou SS, Kong M, Shen H, Mao Q, Zhu H, Chan G, Liu LF, Zhang QW, Li SL. Effects of chromatographic conditions and mass spectrometric parameters on the ionization and fragmentation of triterpene saponins of Ilex asprella in liquid chromatography-mass spectrometry analysis. J Chromatogr A 2019; 1608:460418. [PMID: 31420179 DOI: 10.1016/j.chroma.2019.460418] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Revised: 07/24/2019] [Accepted: 08/02/2019] [Indexed: 02/06/2023]
Abstract
High performance liquid chromatography coupled with quadrupole-time-of-flight mass spectrometry (HPLC-QTOF-MS) is widely used to qualitatively characterize the chemical profiles of herbal medicines, in which the generated adducts and fragments are crucial for confirming molecular ion (deprotonated/protonated ion) and deducing structure of detected components. However, how chromatographic and mass spectrometric (LC-MS) conditions/parameters affect the quantity and intensity of adducts and fragments of detected components is scarcely concerned. In present study, three types of triterpene saponins from the root of Ilex asprella (RIA) were selected as a case study to systematically investigate the effects of LC/MS conditions/parameters on their ionization and fragmentation, so as to obtain higher intensity (higher detection sensitivity) and quantity (rich information) of adducts and fragments for the characterization of components in RIA. It was found that for LC conditions, methanol as organic phase was more benefit for generating more adducts with higher intensity; formic acid as a modifier suppressed the formation of [M-2H]2-, thus promoted the generation of other types of adducts at lower concentration but inhibited the generation when the concentration exceeded 0.1%. MS parameters affect scarcely the quantity but mainly intensity of adducts, cone voltage, source temperature and desolvation gas flow have relatively higher impacts when compared with other parameters. Collision energy affected both quantity and intensity of fragments. MS parameters at the medium value largely increased the quantity and intensity of adducts and fragments. Three-types of triterpene saponins presented structurally specific ionization and fragmentation due to their amounts of acidic substitutes. A total of 55 components were detected and definitely or tentatively identified in RIA under the optimized LC-MS conditions, among which 35 triterpene saponins were firstly discovered. This is the first report that proposes and validates a systematic approach for assessing the effects of LC/MS conditions/parameters on the ionization and fragmentation of analytes, which could be helpful for the optimization of LC-MS conditions for effective chemical profiling analysis of herbal medicines.
Collapse
Affiliation(s)
- Jin-Di Xu
- Department of Pharmaceutical Analysis, Hospital of Integrated Traditional Chinese and Western Medicine Affiliated to Nanjing University of Chinese Medicine, Nanjing, Jiangsu, People's Republic of China
| | - Ming-Zhe Xu
- Department of Metabolomics, Jiangsu Province Academy of Traditional Chinese Medicine and Jiangsu Branch of China Academy of Chinese Medical Sciences, Nanjing, Jiangsu, People's Republic of China; State Key Laboratory of Natural Medicines, Department of Chinese Medicines Analysis, China Pharmaceutical University, Nanjing 210009, PR China
| | - Shan-Shan Zhou
- Department of Pharmaceutical Analysis, Hospital of Integrated Traditional Chinese and Western Medicine Affiliated to Nanjing University of Chinese Medicine, Nanjing, Jiangsu, People's Republic of China
| | - Ming Kong
- Department of Metabolomics, Jiangsu Province Academy of Traditional Chinese Medicine and Jiangsu Branch of China Academy of Chinese Medical Sciences, Nanjing, Jiangsu, People's Republic of China
| | - Hong Shen
- Department of Metabolomics, Jiangsu Province Academy of Traditional Chinese Medicine and Jiangsu Branch of China Academy of Chinese Medical Sciences, Nanjing, Jiangsu, People's Republic of China
| | - Qian Mao
- Department of Pharmaceutical Analysis, Hospital of Integrated Traditional Chinese and Western Medicine Affiliated to Nanjing University of Chinese Medicine, Nanjing, Jiangsu, People's Republic of China
| | - He Zhu
- Department of Metabolomics, Jiangsu Province Academy of Traditional Chinese Medicine and Jiangsu Branch of China Academy of Chinese Medical Sciences, Nanjing, Jiangsu, People's Republic of China
| | - Ging Chan
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macao
| | - Li-Fang Liu
- State Key Laboratory of Natural Medicines, Department of Chinese Medicines Analysis, China Pharmaceutical University, Nanjing 210009, PR China.
| | - Qing-Wen Zhang
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macao.
| | - Song-Lin Li
- Department of Pharmaceutical Analysis, Hospital of Integrated Traditional Chinese and Western Medicine Affiliated to Nanjing University of Chinese Medicine, Nanjing, Jiangsu, People's Republic of China; Department of Metabolomics, Jiangsu Province Academy of Traditional Chinese Medicine and Jiangsu Branch of China Academy of Chinese Medical Sciences, Nanjing, Jiangsu, People's Republic of China.
| |
Collapse
|
75
|
Trang HK, Marcus RK. Application of polydopamine‐coated nylon capillary‐channeled polymer fibers as a stationary phase for mass spectrometric phosphopeptide analysis. Electrophoresis 2019; 41:215-224. [DOI: 10.1002/elps.201900392] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 11/21/2019] [Accepted: 11/25/2019] [Indexed: 12/13/2022]
Affiliation(s)
- Hung K. Trang
- Clemson University Department of Chemistry Biosystems Research Complex Clemson SC USA
| | - R. Kenneth Marcus
- Clemson University Department of Chemistry Biosystems Research Complex Clemson SC USA
| |
Collapse
|
76
|
Rebane R, Kruve A, Liigand J, Liigand P, Gornischeff A, Leito I. Ionization efficiency ladders as tools for choosing ionization mode and solvent in liquid chromatography/mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2019; 33:1834-1843. [PMID: 31381213 DOI: 10.1002/rcm.8545] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 07/26/2019] [Accepted: 07/29/2019] [Indexed: 06/10/2023]
Abstract
RATIONALE The choice of mobile phase components and optimal ion source, mainly electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI), is a crucial part in liquid chromatography/mass spectrometry (LC/MS) method development to achieve higher sensitivity and lower detection limits. In this study we demonstrate how to rigorously solve these questions by using ionization efficiency scales. METHODS Four ionization efficiency scales are used: recorded with both APCI and ESI sources and using both methanol- and acetonitrile-containing mobile phases. Each scale contains altogether more than 50 compounds. In addition, measurements with a chromatographic column were also performed. RESULTS We observed a correlation between calibration graph slopes under LC conditions and logIE values in ESI (but not APCI) thereby validating the use of logIE values for choosing the ion source. Most of the studied compounds preferred ESI as an ion source and methanol as mobile organic phase. APCI remains the ion source of choice for polycyclic aromatic hydrocarbons. For APCI, both acetonitrile and methanol provide similar ionization efficiencies with few exceptions. CONCLUSIONS Overall the results of this work give a concise guideline for practitioners in choosing an ion source for LC/MS analysis on the basis of the chemical nature of the analytes.
Collapse
Affiliation(s)
- Riin Rebane
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Anneli Kruve
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Jaanus Liigand
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Piia Liigand
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Artur Gornischeff
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Ivo Leito
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| |
Collapse
|
77
|
Optimization of microflow LC-MS/MS and its utility in quantitative discovery bioanalysis. Bioanalysis 2019; 11:1117-1127. [PMID: 31251100 DOI: 10.4155/bio-2019-0076] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Aim: The sensitivity advantage of microflow LC (μFLC)-MS/MS is potentially impactful for challenging compounds not detectable by conventional flow LC-MS/MS in drug discovery bioanalysis. Relatively new to μFLC technology, discovery bioanalytical scientists would benefit from an effective strategy for method development and optimization. Results: A systematic μFLC-MS/MS method optimization approach was developed in this study. With optimized conditions, μFLC-MS/MS demonstrated an improved sensitivity compared with conventional LC-MS/MS analysis, ranging from 6× to 49× (by peak area) depending on the compounds, with acceptable analytical performance and robustness. The optimized conditions demonstrated universal applicability to various compounds of diverse properties. Conclusion: The systematic method optimization strategy, and the general applicability of the optimized conditions could facilitate the routine utilization of μFLC in quantitative discovery bioanalysis.
Collapse
|
78
|
Schirinzi GF, Llorca M, Seró R, Moyano E, Barceló D, Abad E, Farré M. Trace analysis of polystyrene microplastics in natural waters. CHEMOSPHERE 2019; 236:124321. [PMID: 31319300 DOI: 10.1016/j.chemosphere.2019.07.052] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Revised: 07/04/2019] [Accepted: 07/06/2019] [Indexed: 05/22/2023]
Abstract
The development of quantitative and qualitative analytical methods to assess micro-plastics (MPLs) and nano-plastics (NPLs) content in the environment is a central issue for realistic risk assessment studies. However, the quantitative analysis continues being a critical issue, in particular for MPLs from 100 μm down to the nano-sized range in complex environmental samples. This paper evaluates the potential of mass spectrometry for the analysis of MPLs and NPLs. The performance of different techniques including matrix-assisted laser desorption ionisation (MALDI) coupled to time-of-flight mass spectrometry (TOF-MS), liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS), and the ambient ionisation approaches as desorption electrospray ionisation (DESI) and direct analysis real-time (DART), were assessed for the study of polystyrene (PS) MPLs and NPLs in natural waters. A method based on LC-HRMS, equipped with an atmospheric pressure photoionisation source (APPI), operated in negative conditions for the quantitative analysis of PS MPLs and NPLs in natural waters, was developed. The chromatographic separation was achieved using an advanced polymer chromatographic (APC) column using toluene isocratic as the mobile phase. The optimal analytical method showed an instrumental limit of detection (ILOD) of 20 pg and methods limits of detection and quantification around 30 pg L-1 and 100 pg L-1, respectively. And, recoveries of 60 and 70% in samples from rivers and the marine coast, respectively. The performance of the new method was proved by the analysis of fortified samples and natural seawater samples.
Collapse
Affiliation(s)
- Gabriella F Schirinzi
- Institute of Environmental Assessment and Water Research, IDAEA-CSIC, Barcelona, Catalonia, Spain
| | - Marta Llorca
- Institute of Environmental Assessment and Water Research, IDAEA-CSIC, Barcelona, Catalonia, Spain
| | - Raquel Seró
- University of Barcelona, Barcelona Catalonia, Spain
| | | | - Damià Barceló
- Institute of Environmental Assessment and Water Research, IDAEA-CSIC, Barcelona, Catalonia, Spain; Catalan Institute for Water Research, ICRA, Girona, Catalonia, Spain
| | - Esteban Abad
- Institute of Environmental Assessment and Water Research, IDAEA-CSIC, Barcelona, Catalonia, Spain
| | - Marinella Farré
- Institute of Environmental Assessment and Water Research, IDAEA-CSIC, Barcelona, Catalonia, Spain.
| |
Collapse
|
79
|
A rational strategy based on experimental designs to optimize parameters of a liquid chromatography-mass spectrometry analysis of complex matrices. Talanta 2019; 205:120063. [DOI: 10.1016/j.talanta.2019.06.063] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Revised: 06/13/2019] [Accepted: 06/16/2019] [Indexed: 12/21/2022]
|
80
|
Murcia-Morales M, Cutillas V, Fernández-Alba AR. Supercritical Fluid Chromatography and Gas Chromatography Coupled to Tandem Mass Spectrometry for the Analysis of Pyrethroids in Vegetable Matrices: A Comparative Study. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2019; 67:12626-12632. [PMID: 31062971 DOI: 10.1021/acs.jafc.9b00732] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
This study describes a comprehensive comparison between supercritical fluid chromatography (SFC) and gas chromatography (GC) coupled to mass spectrometry for the analysis of pyrethroids in vegetable matrices. The ionization process used was electrospray ionization (ESI) in SFC and electron ionization in GC. In general, liquid chromatography coupled to mass spectrometry with ESI sources provides poor results for pyrethroid detection, as described in previous literature. A total of 14 pyrethroids were selected, together with 6 representative matrices. The differences in chromatographic separation and ionization process were assessed. Similar results were obtained in terms of sensitivity (limits of quantification close to 2 μg/kg, injecting the same amount of sample), matrix effect, and linearity. A total of 17 real samples were analyzed by both systems, obtaining similar results. These data suggest that SFC offers a suitable alternative to GC in the analysis of pyrethroids and allows for their inclusion in a wider multiresidue method.
Collapse
Affiliation(s)
- María Murcia-Morales
- Agrifood Campus of International Excellence (ceiA3), European Union Reference Laboratory for Pesticide Residues in Fruit and Vegetables, Department of Hydrogeology and Analytical Chemistry , University of Almería , Carretera Sacramento s/n , La Cañada de San Urbano, 04120 Almería , Spain
| | - Víctor Cutillas
- Agrifood Campus of International Excellence (ceiA3), European Union Reference Laboratory for Pesticide Residues in Fruit and Vegetables, Department of Hydrogeology and Analytical Chemistry , University of Almería , Carretera Sacramento s/n , La Cañada de San Urbano, 04120 Almería , Spain
| | - Amadeo R Fernández-Alba
- Agrifood Campus of International Excellence (ceiA3), European Union Reference Laboratory for Pesticide Residues in Fruit and Vegetables, Department of Hydrogeology and Analytical Chemistry , University of Almería , Carretera Sacramento s/n , La Cañada de San Urbano, 04120 Almería , Spain
| |
Collapse
|
81
|
da Silva LAL, Sandjo LP, Misturini A, Caramori GF, Biavatti MW. ESI-QTof-MS characterization of hirsutinolide and glaucolide sesquiterpene lactones: Fragmentation mechanisms and differentiation based on Na + /H + adducts interactions in complex mixture. JOURNAL OF MASS SPECTROMETRY : JMS 2019; 54:915-932. [PMID: 31476247 DOI: 10.1002/jms.4433] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 08/09/2019] [Accepted: 08/26/2019] [Indexed: 06/10/2023]
Abstract
Sesquiterpene lactones (SL) have been reported with various biological effects. Among the described SL skeletons, hirsutinolide and glaucolide have not been extensively studied by mass spectrometry (MS), especially how to distinguish them in organic matrices. Thus, this paper reports (1) a strategy of their differentiation based on MS behavior during the ionization and (2) a proposal of the fragmentation pattern for both SL-subtypes. ESI(+)-HRMS data of four isolated SL (hirsutinolides 1 and 3; glaucolides 2 and 4) were recorded by direct and UPLC water-sample combined injections. These analyses revealed that hirsutinolides and glaucolides formed [M+Na]+ ion during the operation of the direct MS injection, and ([M+Na]+ and [M+H-H2 O]+ ) and [M+H]+ ions were respectively observed for hirsutinolides and glaucolides during the operation of combined UPLC water and sample MS injection. Computational simulations showed that the complex hirsutinolide (1)-Na+ formed with a lower preparation energy compared with the complex glaucolide (2)-Na+ . However, despite their different behavior during the ionization process, ESI(+)-HRMS/MS analyses of 1-4 gave similar fragmentation patterns at m/z 277, 259, 241, and 231 that can be used as diagnostic ions for both skeletons. Moreover, the differentiation strategy based on the nature of the complex SL-adducts and their MS/MS fragmentation pattern were successfully applied for the chemical characterization of the extract from Vernonanthura tweedieana using UPLC-ESI-HRMS/MS. Among the characterized metabolites, SL with hirsutinolide and glaucolide skeletons showed the aforementioned diagnostic fragments and an ionization behavior that was similar to those observed during the water-sample combined injection.
Collapse
Affiliation(s)
- Layzon A L da Silva
- Department of Pharmaceutical Sciences, Universidade Federal de Santa Catarina, Campus Universitário-Trindade, Florianópolis, Florianópolis, SC, CEP, 88040-970, Brazil
| | - Louis P Sandjo
- Department of Pharmaceutical Sciences, Universidade Federal de Santa Catarina, Campus Universitário-Trindade, Florianópolis, Florianópolis, SC, CEP, 88040-970, Brazil
| | - Alechania Misturini
- Department of Chemistry, Universidade Federal de Santa Catarina, Campus Universitário-Trindade, Florianópolis, Florianópolis, SC, CEP, 88040-900, Brazil
| | - Giovanni F Caramori
- Department of Chemistry, Universidade Federal de Santa Catarina, Campus Universitário-Trindade, Florianópolis, Florianópolis, SC, CEP, 88040-900, Brazil
| | - Maique W Biavatti
- Department of Pharmaceutical Sciences, Universidade Federal de Santa Catarina, Campus Universitário-Trindade, Florianópolis, Florianópolis, SC, CEP, 88040-970, Brazil
| |
Collapse
|
82
|
Direct and indirect quantification of phosphate metabolites of nucleoside analogs in biological samples. J Pharm Biomed Anal 2019; 178:112902. [PMID: 31610397 DOI: 10.1016/j.jpba.2019.112902] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Revised: 08/22/2019] [Accepted: 09/29/2019] [Indexed: 12/19/2022]
Abstract
Nucleoside reverse transcriptase inhibitors (NRTIs) are prodrugs that require intracellular phosphorylation to active triphosphate nucleotide metabolites (NMs) for their pharmacological activity. However, monitoring these pharmacologically active NMs is challenging due to their instability, high hydrophilicity, and their low concentrations in blood and tissues. Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) is the gold standard technique for the quantification of NRTIs and their phosphorylated NMs. In this review, an overview of the publications describing the quantitative analysis of intracellular and total tissue concentration of NMs is presented. The focus of this review is the comparison of the different approaches and challenges associated with sample collection, tissue homogenization, cell lysis, cell counting, analyte extraction, sample storage conditions, and LC-MS analysis. Quantification methods of NMs via LC-MS can be categorized into direct and indirect methods. In the direct LC-MS methods, chromatographic retention of the NMs is accomplished by ion-exchange (IEX), ion-pairing (IP), hydrophilic interaction (HILIC), porous graphitic carbon (PGC) chromatography, or capillary electrophoresis (CE). In indirect methods, parent nucleosides are 1st generated from the dephosphorylation of NMs during sample preparation and are then quantified by reverse phase LC-MS as surrogates for their corresponding NMs. Both approaches have advantages and disadvantages associated with them, which are discussed in this review.
Collapse
|
83
|
Quantitative analysis of cholesterol oxidation products and desmosterol in parenteral liposomal pharmaceutical formulations. Int J Pharm 2019; 569:118576. [DOI: 10.1016/j.ijpharm.2019.118576] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Revised: 07/22/2019] [Accepted: 07/25/2019] [Indexed: 11/19/2022]
|
84
|
Yan Y, Xing T, Wang S, Daly TJ, Li N. Coupling Mixed-Mode Size Exclusion Chromatography with Native Mass Spectrometry for Sensitive Detection and Quantitation of Homodimer Impurities in Bispecific IgG. Anal Chem 2019; 91:11417-11424. [DOI: 10.1021/acs.analchem.9b02793] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Affiliation(s)
- Yuetian Yan
- Analytical Chemistry Group, Regeneron Pharmaceuticals Inc., 777 Old Saw Mill River Road, Tarrytown, New York 10591-6707, United States
| | - Tao Xing
- Analytical Chemistry Group, Regeneron Pharmaceuticals Inc., 777 Old Saw Mill River Road, Tarrytown, New York 10591-6707, United States
| | - Shunhai Wang
- Analytical Chemistry Group, Regeneron Pharmaceuticals Inc., 777 Old Saw Mill River Road, Tarrytown, New York 10591-6707, United States
| | - Thomas J. Daly
- Analytical Chemistry Group, Regeneron Pharmaceuticals Inc., 777 Old Saw Mill River Road, Tarrytown, New York 10591-6707, United States
| | - Ning Li
- Analytical Chemistry Group, Regeneron Pharmaceuticals Inc., 777 Old Saw Mill River Road, Tarrytown, New York 10591-6707, United States
| |
Collapse
|
85
|
Zebrowska A, Skowronek A, Wojakowska A, Widlak P, Pietrowska M. Metabolome of Exosomes: Focus on Vesicles Released by Cancer Cells and Present in Human Body Fluids. Int J Mol Sci 2019; 20:ijms20143461. [PMID: 31337156 PMCID: PMC6678201 DOI: 10.3390/ijms20143461] [Citation(s) in RCA: 59] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Revised: 07/10/2019] [Accepted: 07/11/2019] [Indexed: 02/07/2023] Open
Abstract
Exosomes and other classes of extracellular vesicles (EVs) have gained interest due to their role in cell-to-cell communication. Knowledge of the molecular content of EVs may provide important information on features of parental cells and mechanisms of cross-talk between cells. To study functions of EVs it is essential to know their composition, that includes proteins, nucleic acids, and other classes biomolecules. The metabolome, set of molecules the most directly related to the cell phenotype, is the least researched component of EVs. However, the metabolome of EVs circulating in human blood and other bio-fluids is of particular interest because of its potential diagnostic value in cancer and other health conditions. On the other hand, the metabolome of EVs released to culture media in controlled conditions in vitro could shed light on important aspects of communication between cells in model systems. This paper summarizes the most common approaches implemented in EV metabolomics and integrates currently available data on the composition of the metabolome of EVs obtained in different models with particular focus on human body fluids and cancer cells.
Collapse
Affiliation(s)
- Aneta Zebrowska
- Maria Sklodowska-Curie Institute-Oncology Center, Gliwice Branch, 44-100 Gliwice, Poland
| | - Agata Skowronek
- Maria Sklodowska-Curie Institute-Oncology Center, Gliwice Branch, 44-100 Gliwice, Poland
| | - Anna Wojakowska
- Institute of Bioorganic Chemistry, Polish Academy of Sciences, 44-100 Poznan, Poland
| | - Piotr Widlak
- Maria Sklodowska-Curie Institute-Oncology Center, Gliwice Branch, 44-100 Gliwice, Poland
| | - Monika Pietrowska
- Maria Sklodowska-Curie Institute-Oncology Center, Gliwice Branch, 44-100 Gliwice, Poland.
| |
Collapse
|
86
|
Scotti G, Nilsson SM, Matilainen VP, Haapala M, Boije af Gennäs G, Yli-Kauhaluoma J, Salminen A, Kotiaho T. Simple 3D printed stainless steel microreactors for online mass spectrometric analysis. Heliyon 2019; 5:e02002. [PMID: 31312730 PMCID: PMC6609794 DOI: 10.1016/j.heliyon.2019.e02002] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2018] [Revised: 04/10/2019] [Accepted: 06/20/2019] [Indexed: 12/03/2022] Open
Abstract
A simple flow chemistry microreactor with an electrospray ionization tip for real time mass spectrometric reaction monitoring is introduced. The microreactor was fabricated by a laser-based additive manufacturing technique from acid-resistant stainless steel 316L. The functionality of the microreactor was investigated by using an inverse electron demand Diels-Alder and subsequent retro Diels-Alder reaction for testing. Challenges and problems encountered are discussed and improvements proposed. Adsorption of reagents to the rough stainless steel channel walls, short length of the reaction channel, and making a proper ESI tip present challenges, but the microreactor is potentially useful as a disposable device.
Collapse
Affiliation(s)
- Gianmario Scotti
- Drug Research Program, Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, P.O. Box 56 (Viikinkaari 5 E), FI-00014, University of Helsinki, Finland
| | - Sofia M.E. Nilsson
- Drug Research Program, Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, P.O. Box 56 (Viikinkaari 5 E), FI-00014, University of Helsinki, Finland
| | - Ville-Pekka Matilainen
- Laser Processing Research Group, Lappeenranta University of Technology, Tuotantokatu 2, FI-53850, Lappeenranta, Finland
| | - Markus Haapala
- Drug Research Program, Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, P.O. Box 56 (Viikinkaari 5 E), FI-00014, University of Helsinki, Finland
| | - Gustav Boije af Gennäs
- Drug Research Program, Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, P.O. Box 56 (Viikinkaari 5 E), FI-00014, University of Helsinki, Finland
| | - Jari Yli-Kauhaluoma
- Drug Research Program, Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, P.O. Box 56 (Viikinkaari 5 E), FI-00014, University of Helsinki, Finland
| | - Antti Salminen
- Laser Processing Research Group, Lappeenranta University of Technology, Tuotantokatu 2, FI-53850, Lappeenranta, Finland
| | - Tapio Kotiaho
- Drug Research Program, Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, P.O. Box 56 (Viikinkaari 5 E), FI-00014, University of Helsinki, Finland
- Department of Chemistry, Faculty of Science, P.O. Box 55 (A.I. Virtasen aukio 1), FI-00014, University of Helsinki, Finland
| |
Collapse
|
87
|
Striesow J, Lackmann JW, Ni Z, Wenske S, Weltmann KD, Fedorova M, von Woedtke T, Wende K. Oxidative modification of skin lipids by cold atmospheric plasma (CAP): A standardizable approach using RP-LC/MS 2 and DI-ESI/MS 2. Chem Phys Lipids 2019; 226:104786. [PMID: 31229410 DOI: 10.1016/j.chemphyslip.2019.104786] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Revised: 06/12/2019] [Accepted: 06/13/2019] [Indexed: 12/18/2022]
Abstract
Cold atmospheric plasma (CAP) is an emerging source for the locally defined delivery of reactive species, and its clinical potential has been identified in the control of inflammatory processes, such as acute and chronic wounds, or cancerous lesions. Lipids, due to their localization and chemical structure as ideal targets for oxidative species, are relevant modifiers of physiological processes. Human forehead lipids collected on a target were treated by an argon plasma jet and immediately analyzed by direct-infusion high-resolution tandem mass spectrometry (DI-MS2) or liquid chromatography-tandem MS (RP-LC/MS2). Subsequent data analysis was performed by LipidHunter (University of Leipzig), LipidXplorer (Max Planck Institute of Molecular Cell Biology and Genetics, Dresden), and LipidSearch (Thermo Scientific). With either MS method, all major lipid classes of sebum lipids were detected. Significant differences regarding triacylglycerols (predominantly identified in RP-LC/MS2) and ceramides (predominantly identified in DI-MS2) indicate experimental- or approach-inherent distinctions. A CAP-driven oxidation of triacyclglycerols, ceramides, and cholesteryl esters was detected such as truncations and hydroperoxylations, but at a significantly lower extent than expected. Scavenging of reactive species due to naturally present antioxidants in the samples and the absence of a liquid interphase to allow reactive species deposition by the CAP will have contributed to the limited amount of oxidation products observed. In addition, limitations of the software's capability of identifying unexpected oxidized lipids potentially led to an underestimation of the CAP impact on skin lipids, indicating a need for further software development. With respect to the clinical application of CAP, the result indicates that intact skin with its sebum/epidermal lipid overlay is well protected and that moderate treatment will yield limited (if any) functional consequences in the dermal tissue.
Collapse
Affiliation(s)
- Johanna Striesow
- ZIK Plasmatis, Leibniz Institute for Plasma Science and Technology (INP Greifswald), Felix-Hausdorff-Straße 2, 17489 Greifswald, Germany
| | - Jan-Wilm Lackmann
- ZIK Plasmatis, Leibniz Institute for Plasma Science and Technology (INP Greifswald), Felix-Hausdorff-Straße 2, 17489 Greifswald, Germany
| | - Zhixu Ni
- Center for Biotechnology and Biomedicine, University of Leipzig, Deutscher Platz 5, 04103 Leipzig, Germany; Institute of Bioanalytical Chemistry, Faculty of Chemistry and Mineralogy, University of Leipzig, Germany
| | - Sebastian Wenske
- ZIK Plasmatis, Leibniz Institute for Plasma Science and Technology (INP Greifswald), Felix-Hausdorff-Straße 2, 17489 Greifswald, Germany
| | - Klaus-Dieter Weltmann
- Leibniz Institute for Plasma Science and Technology (INP Greifswald), Felix-Hausdorff-Straße 2, 17489 Greifswald, Germany
| | - Maria Fedorova
- Center for Biotechnology and Biomedicine, University of Leipzig, Deutscher Platz 5, 04103 Leipzig, Germany; Institute of Bioanalytical Chemistry, Faculty of Chemistry and Mineralogy, University of Leipzig, Germany
| | - Thomas von Woedtke
- Leibniz Institute for Plasma Science and Technology (INP Greifswald), Felix-Hausdorff-Straße 2, 17489 Greifswald, Germany; Greifswald University Medicine, Fleischmannstraße 8, 17475 Greifswald, Germany
| | - Kristian Wende
- ZIK Plasmatis, Leibniz Institute for Plasma Science and Technology (INP Greifswald), Felix-Hausdorff-Straße 2, 17489 Greifswald, Germany.
| |
Collapse
|
88
|
Strategies and analytical workflows to extend the dynamic range in quantitative LC–MS/MS analysis. Bioanalysis 2019; 11:1189-1206. [DOI: 10.4155/bio-2018-0309] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Aim: To evaluate alternative analytical strategies to extend the dynamic range in quantitative LC–MS/MS. Methods & results: Two approaches based on prior or no prior knowledge of expected exposure levels were evaluated. These approaches make use of two analytical strategies, which include the use of more than one injection volume or dilution of sample extract with solvents or solvent mixtures. A total of 16 compounds with varying logP values were classified into polar and nonpolar groups and used in this evaluation. From the two analytical strategies, three workflows were derived. Conclusion: All three workflows were successfully evaluated and resulted in good accuracy (80–120%) for all the compound groups.
Collapse
|
89
|
Cutillas V, Murcia-Morales M, Gómez-Ramos MDM, Taha SM, Fernández-Alba AR. Supercritical fluid chromatography coupled to tandem mass spectrometry for the analysis of pesticide residues in dried spices. Benefits and drawbacks. Anal Chim Acta 2019; 1059:124-135. [DOI: 10.1016/j.aca.2019.01.010] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2018] [Revised: 12/05/2018] [Accepted: 01/07/2019] [Indexed: 12/13/2022]
|
90
|
Liigand P, Kaupmees K, Kruve A. Influence of the amino acid composition on the ionization efficiencies of small peptides. JOURNAL OF MASS SPECTROMETRY : JMS 2019; 54:481-487. [PMID: 30849787 DOI: 10.1002/jms.4348] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Revised: 02/27/2019] [Accepted: 02/28/2019] [Indexed: 05/19/2023]
Abstract
Electrospray ionization is widely used to generate gas phase ions from a variety of molecules ranging from small ions to large proteins, while the ionization mechanism is claimed to depend on the size of the molecule. For small molecules, the ionization efficiency, the amount of gas phase ions produced in the electrospray process, depends on the properties of the compound. Here, we show that the amino acid composition also influences the ionization efficiency of the oligopeptide. Additionally, we show that the ionization efficiencies of oligopeptides consisting of more than five amino acid residues are very similar to one another, and assuming equal ionization efficiencies is feasible. Therefore, accurate ionization efficiency predictions are needed mainly for small oligopeptides. For these oligopeptides, the amino acid composition can be used to estimate the ionization efficiency in an easy to use manner.
Collapse
Affiliation(s)
- Piia Liigand
- Institute of Chemistry, Faculty of Science and Technology, University of Tartu, Tartu, Estonia
| | - Karl Kaupmees
- Institute of Chemistry, Faculty of Science and Technology, University of Tartu, Tartu, Estonia
| | - Anneli Kruve
- Institute of Chemistry, Faculty of Science and Technology, University of Tartu, Tartu, Estonia
- Institut für Chemie und Biochemie, Freie Universität Berlin, Berlin, Germany
| |
Collapse
|
91
|
Yang W, Wang S, Zhang G, Wu S, Chen T, Wang Q, Wei M, Cheng W, Gao Y, Li Y, Ye Z. LC-electrolyte switch in a contiguous time segments to analyze multi-components: Simultaneous determination of phenolic acids and iridoids in rat plasma after inhalation administration of Reduning aerosol. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1120:104-112. [PMID: 31078127 DOI: 10.1016/j.jchromb.2019.05.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Revised: 04/29/2019] [Accepted: 05/02/2019] [Indexed: 11/29/2022]
Abstract
The optimization of electrolytes, kinds and concentrations, in mobile phase for multiple constituents analyzing using high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS) was usually compromised to ensure good LC separation of partial components. However, the compromised electrolytes could lead to ionization suppression of some of the analytes. To solve the compromise of electrolytes within various components, taking phenolic acids and iridoids as a case, we used electrolyte switch in contiguous running time segments of UPLC-ESI-MS/MS to ensure chromatographic separation of chlorogenic acid, neochlorogenic acid and cryptochlorogenic acid and improve the response of geniposide. Then the method was applied for pharmacokinetic study of the four components in rat after inhaling Reduning aerosol for the first time. The complete separation of the three chlorogenic acid isomers was achieved and the LLOQs of neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid, and geniposide were 1, 1, 3, and 0.2 ng/mL, respectively. In conclusion, we developed a sensitive and time-saving LC-MS/MS method for the quantitative analysis of chlorogenic acid, neochlorogenic acid, cryptochlorogenic acid, and geniposide in rat plasma, and this method appears to be useful for pharmacokinetic studies of Reduning aerosol. The method provided a sight to alleviate compromise of electrolytes in mobile phase for HPLC-ESI-MS in analyzing multi-components.
Collapse
Affiliation(s)
- Wei Yang
- Center for DMPK Research of Herbal Medicines, Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing 100700, China
| | - Shuyao Wang
- Center for DMPK Research of Herbal Medicines, Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing 100700, China
| | - Guangping Zhang
- Research Center for Atomized Inhalation Agents of Institute of Chinese Materia Medica, China Academy of Chinese Medical Science, Beijing 100700, China
| | - Siyang Wu
- Center for DMPK Research of Herbal Medicines, Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing 100700, China
| | - Tengfei Chen
- Research Center for Atomized Inhalation Agents of Institute of Chinese Materia Medica, China Academy of Chinese Medical Science, Beijing 100700, China
| | - Qiutao Wang
- No. 1 Senior High School, Qingdao West Coast New Area, Shandong, China
| | - Mengmeng Wei
- Center for DMPK Research of Herbal Medicines, Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing 100700, China
| | - Wenhao Cheng
- School of Chinese Pharmacy, Beijing University of Chinese Medicine, Beijing 100102, China
| | - Yang Gao
- Center for DMPK Research of Herbal Medicines, Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing 100700, China
| | - Yingfei Li
- Center for DMPK Research of Herbal Medicines, Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing 100700, China.
| | - Zuguang Ye
- Research Center for Atomized Inhalation Agents of Institute of Chinese Materia Medica, China Academy of Chinese Medical Science, Beijing 100700, China.
| |
Collapse
|
92
|
Dubrovskii Y, Murashko E, Chuprina O, Beltyukov P, Radilov A, Solovyev N, Babakov V. Mass spectrometry based proteomic approach for the screening of butyrylcholinesterase adduct formation with organophosphates. Talanta 2019; 197:374-382. [DOI: 10.1016/j.talanta.2019.01.059] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2018] [Revised: 01/13/2019] [Accepted: 01/15/2019] [Indexed: 11/29/2022]
|
93
|
Erngren I, Haglöf J, Engskog MKR, Nestor M, Hedeland M, Arvidsson T, Pettersson C. Adduct formation in electrospray ionisation-mass spectrometry with hydrophilic interaction liquid chromatography is strongly affected by the inorganic ion concentration of the samples. J Chromatogr A 2019; 1600:174-182. [PMID: 31047661 DOI: 10.1016/j.chroma.2019.04.049] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Revised: 04/15/2019] [Accepted: 04/17/2019] [Indexed: 12/14/2022]
Abstract
Hydrophilic interaction liquid chromatography (HILIC)/ electrospray ionisation-mass spectrometry (ESI-MS) has gained interest for the analysis of polar analytes in bioanalytical applications in recent years. However, ESI-MS is prone to adduct formation of analytes. In contrast to reversed phase chromatography, small inorganic ions have retention in HILIC, i.e. analytes and inorganic ions may co-elute, which could influence the adduct formation. In the present paper, it was demonstrated that the co-elution of sodium ions or potassium ions and analytes in HILIC/ESI-MS affect the adduct formation and that different concentrations of sodium ions and potassium ions in biological samples could have an impact on the quantitative response of the respective adducts as well as the quantitative response of the protonated adduct. The co-elution also lead to cluster formation of analytes and sodium formate or potassium formate, causing extremely complicated spectra. In analytical applications using HILIC/ESI-MS where internal standards are rarely used or not properly matched, great care needs to be taken to ensure minimal variation of inorganic ion concentration between samples. Moreover, the use of alkali metal ion adducts as quantitative target ions in relative quantitative applications should be made with caution if proper internal standards are not used.
Collapse
Affiliation(s)
- Ida Erngren
- Department of Medicinal Chemistry, Uppsala University, Uppsala, Sweden.
| | - Jakob Haglöf
- Department of Medicinal Chemistry, Uppsala University, Uppsala, Sweden
| | | | - Marika Nestor
- Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden
| | - Mikael Hedeland
- Department of Medicinal Chemistry, Uppsala University, Uppsala, Sweden; National Veterinary Institute (SVA), Department of Chemistry, Environment and Feed Hygiene, Uppsala, Sweden
| | - Torbjörn Arvidsson
- Department of Medicinal Chemistry, Uppsala University, Uppsala, Sweden; Medical Product Agency, Uppsala, Sweden
| | - Curt Pettersson
- Department of Medicinal Chemistry, Uppsala University, Uppsala, Sweden
| |
Collapse
|
94
|
Chung H, Tajiri S, Hyoguchi M, Koyanagi R, Shimura A, Takata F, Dohgu S, Matsui T. Analysis of Catecholamine and Their Metabolites in Mice Brain by Liquid Chromatography-Mass Spectrometry Using Sulfonated Mixed-mode Copolymer Column. ANAL SCI 2019; 35:433-439. [PMID: 30584183 DOI: 10.2116/analsci.18p494] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
In this study, a simultaneous assay for catecholamines and their metabolites in the brain was established using liquid chromatography-mass spectrometry (LC-MS). To achieve complete separation, a cation-exchange/reversed-phase mixed-mode copolymer resin column containing 0.81 wt% sulfo groups was used for the simultaneous LC-MS assay. The analyzed catecholamines were dopamine (DA), norepinephrine (NE), and epinephrine (E), while the metabolites lacking amino groups were 3,4-dihydroxyphenylacetic acid (DOPAC), homovanillic acid (HVA), and 3-methoxy-4-hydroxyphenylglycol (MHPG). The metabolites were separated and detected using LC-MS, on columns with and without sulfo groups. However, we could not achieve adequate separation of catecholamines on both columns using a gradient elution of 0 - 50 (v/v)% methanol containing 0.1 (v/v)% formic acid (FA). When volatile ion-pairing reagents were added to the mobile phase, they improved the retention and detection of catecholamines on the sulfonated mixed-mode column. Under optimized elution conditions, which involved a linear gradient elution of water containing 0.1 (v/v)% FA to 50 (v/v)% acetonitrile in 50 mM ammonium formate at 40°C and a 0.20 mL/min rate, all six target molecules were simultaneously detected within 25 min, when using negative mode LC-MS on a sulfonated mixed-mode column. The limits of detection (LODs) for DA, NE, E, DOPCA, HVA, and MHPG were determined to be 20.7, 12.6, 74.6, 1110, 18.7, and 3196 nM, respectively. Moreover, the established LC-MS assay allowed the detection of endogenous DA, NE, and HVA, in normal mouse brain samples at concentrations higher than 20, 9, and 4 pmol/mg, respectively.
Collapse
Affiliation(s)
- Hsuan Chung
- Department of Bioscience and Biotechnology, Faculty of Agriculture, Graduate School of Kyushu University
| | - Satoshi Tajiri
- Department of Bioscience and Biotechnology, Faculty of Agriculture, Graduate School of Kyushu University
| | - Mai Hyoguchi
- Department of Bioscience and Biotechnology, Faculty of Agriculture, Graduate School of Kyushu University
| | - Riho Koyanagi
- Department of Bioscience and Biotechnology, Faculty of Agriculture, Graduate School of Kyushu University
| | - Akihiro Shimura
- Separation Materials Laboratory, Kurosaki R & D Center, Mitsubishi Chemical Co
| | - Fuyuko Takata
- Department of Pharmaceutical Care and Health Sciences, Faculty of Pharmaceutical Sciences, Fukuoka University
| | - Shinya Dohgu
- Department of Pharmaceutical Care and Health Sciences, Faculty of Pharmaceutical Sciences, Fukuoka University
| | - Toshiro Matsui
- Department of Bioscience and Biotechnology, Faculty of Agriculture, Graduate School of Kyushu University
| |
Collapse
|
95
|
Ladd MP, Giannone RJ, Abraham PE, Wullschleger SD, Hettich RL. Evaluation of an untargeted nano-liquid chromatography-mass spectrometry approach to expand coverage of low molecular weight dissolved organic matter in Arctic soil. Sci Rep 2019; 9:5810. [PMID: 30967565 PMCID: PMC6456581 DOI: 10.1038/s41598-019-42118-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2018] [Accepted: 03/14/2019] [Indexed: 11/17/2022] Open
Abstract
Characterizing low molecular weight (LMW) dissolved organic matter (DOM) in soils and evaluating the availability of this labile pool is critical to understanding the underlying mechanisms that control carbon storage or release across terrestrial systems. However, due to wide-ranging physicochemical diversity, characterizing this complex mixture of small molecules and how it varies across space remains an analytical challenge. Here, we evaluate an untargeted approach to detect qualitative and relative-quantitative variations in LMW DOM with depth using water extracts from a soil core from the Alaskan Arctic, a unique system that contains nearly half the Earth's terrestrial carbon and is rapidly warming due to climate change. We combined reversed-phase and hydrophilic interaction liquid chromatography, and nano-electrospray ionization coupled with high-resolution tandem mass spectrometry in positive- and negative-ionization mode. The optimized conditions were sensitive, robust, highly complementary, and enabled detection and putative annotations of a wide range of compounds (e.g. amino acids, plant/microbial metabolites, sugars, lipids, peptides). Furthermore, multivariate statistical analyses revealed subtle but consistent and significant variations with depth. Thus, this platform is useful not only for characterizing LMW DOM, but also for quantifying relative variations in LMW DOM availability across space, revealing hotspots of biogeochemical activity for further evaluation.
Collapse
Affiliation(s)
- Mallory P Ladd
- Bredesen Center for Interdisciplinary Research & Graduate Education, University of Tennessee, Knoxville, TN, 37996, USA
- Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN, 37830, USA
| | - Richard J Giannone
- Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN, 37830, USA
| | - Paul E Abraham
- Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN, 37830, USA
| | - Stan D Wullschleger
- Bredesen Center for Interdisciplinary Research & Graduate Education, University of Tennessee, Knoxville, TN, 37996, USA
- Environmental Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN, 37830, USA
| | - Robert L Hettich
- Bredesen Center for Interdisciplinary Research & Graduate Education, University of Tennessee, Knoxville, TN, 37996, USA.
- Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN, 37830, USA.
| |
Collapse
|
96
|
Xie J, Zheng Y, Liu X, Dong F, Xu J, Wu X, Ji M, Zheng Y. Human health safety studies of a new insecticide: Dissipation kinetics and dietary risk assessment of afidopyropen and one of its metabolites in cucumber and nectarine. Regul Toxicol Pharmacol 2019; 103:150-157. [DOI: 10.1016/j.yrtph.2019.01.025] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2018] [Revised: 01/10/2019] [Accepted: 01/16/2019] [Indexed: 12/11/2022]
|
97
|
Development of a screening and confirmatory method for the analysis of polar endogenous compounds in saliva based on a liquid chromatographic-tandem mass spectrometric system. J Chromatogr A 2019; 1590:88-95. [DOI: 10.1016/j.chroma.2019.01.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Revised: 12/10/2018] [Accepted: 01/01/2019] [Indexed: 02/06/2023]
|
98
|
Medina S, Collado-González J, Ferreres F, Londoño-Londoño J, Jiménez-Cartagena C, Guy A, Durand T, Galano JM, Gil-Izquierdo Á. Potential of Physalis peruviana calyces as a low-cost valuable resource of phytoprostanes and phenolic compounds. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE 2019; 99:2194-2204. [PMID: 30315579 DOI: 10.1002/jsfa.9413] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2017] [Revised: 09/11/2018] [Accepted: 10/06/2018] [Indexed: 06/08/2023]
Abstract
BACKGROUND In Colombia, agro-industrial residues represent an enormous economic and environmental problem, which could be reduced if different techniques for the addition of value to such residues were implemented by this industrial sector. One of the fruits with the highest export rates is Physalis peruviana (goldenberry); however, this fruit is generally marketed without its calyx, generating a large amount of residues. To develop a strategy to add value to these residues, it is essential to know their chemical composition. RESULTS In the present work, phytoprostanes (PhytoPs) - new active oxylipins - have been detected for the first time in Physalis peruviana calyces by ultra-high performance liquid chromatography triple quadrupole tandem mass spectrometry (UHPLC-QqQ-MS/MS), F1t -phytoprostanes and D1t -phytoprostanes being the predominant and minor classes, respectively. In addition, we were able to characterize the phenolic compounds profile of this matrix using LC-IT-DAD-MS/MS, describing six phenolic derivatives for the first time therein. CONCLUSIONS This study increases our knowledge of the chemical composition of the calyces of this fruit and thereby supports the recycling of this class of residue. Consequently, goldenberry calyces could be used as phytotherapeutic, nutraceutic, or cosmetic ingredients for the development of diverse natural products. © 2018 Society of Chemical Industry.
Collapse
Affiliation(s)
- Sonia Medina
- Research Group on Quality, Safety and Bioactivity of Plant Foods, Department of Food Science and Technology, CEBAS (CSIC), Murcia, Spain
- Faculty of Engineering, Food Engineering Program, Corporación Universitaria Lasallista, Caldas, Colombia
| | - Jacinta Collado-González
- Research Group on Quality, Safety and Bioactivity of Plant Foods, Department of Food Science and Technology, CEBAS (CSIC), Murcia, Spain
| | - Federico Ferreres
- Research Group on Quality, Safety and Bioactivity of Plant Foods, Department of Food Science and Technology, CEBAS (CSIC), Murcia, Spain
| | - Julián Londoño-Londoño
- Faculty of Engineering, Food Engineering Program, Corporación Universitaria Lasallista, Caldas, Colombia
| | - Claudio Jiménez-Cartagena
- Faculty of Engineering, Food Engineering Program, Corporación Universitaria Lasallista, Caldas, Colombia
| | - Alexandre Guy
- Institut des Biomolécules Max Mousseron, UMR 5247 CNRS-University of Montpellier - ENSCM, Montpellier, France
| | - Thierry Durand
- Institut des Biomolécules Max Mousseron, UMR 5247 CNRS-University of Montpellier - ENSCM, Montpellier, France
| | - Jean-Marie Galano
- Institut des Biomolécules Max Mousseron, UMR 5247 CNRS-University of Montpellier - ENSCM, Montpellier, France
| | - Ángel Gil-Izquierdo
- Research Group on Quality, Safety and Bioactivity of Plant Foods, Department of Food Science and Technology, CEBAS (CSIC), Murcia, Spain
| |
Collapse
|
99
|
Son CE, Choi SS. Influence of smear matrix types on detection behaviors and efficiencies of polycyclic aromatic hydrocarbons using ion mobility spectrometry. CHEMOSPHERE 2019; 218:368-375. [PMID: 30476768 DOI: 10.1016/j.chemosphere.2018.11.116] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Revised: 11/02/2018] [Accepted: 11/17/2018] [Indexed: 06/09/2023]
Abstract
Influence of smear matrix types on detection behaviors and efficiencies of polycyclic aromatic hydrocarbons (PAHs) with different molecular weights in ion mobility spectrometry (IMS) were investigated. Various smear matrices of stainless steel mesh (SM), cellulose paper (CP), and cotton fabric (CF) were employed. Anisole was used as the solvent and IMS analysis was performed without evaporation step of the solvent to apply charge transfer reactions between PAH molecules and the molecular ions of solvent. Shapes of reactant ion peaks (RIPs) were varied according to the smear matrix types. At the beginning of the sample inlet, intensity of RIPs of air and moisture notably decreased due to the lots of solvent vapor. The SM with good gas permeability showed relatively strong RIPs of air and moisture, whereas the CP with no gas permeability showed weak ones. Detection times and efficiencies of PAH ions were varied according to the smear matrix types as well as the kinds of PAHs. PAHs were on the whole detected well in 1-3 s after the sample inlet. Detection limits of PAHs measured using the SM were slightly better than those measured using the CP, while those measured using the CP were much better than those measured using the CF. The experimental results could be explained by structures of the smear matrices and evaporation behaviors of the PAH solutions.
Collapse
Affiliation(s)
- Chae Eun Son
- Department of Chemistry, Sejong University, 209 Neungdong-ro, Gwangjin-gu, Seoul 05006, Republic of Korea
| | - Sung-Seen Choi
- Department of Chemistry, Sejong University, 209 Neungdong-ro, Gwangjin-gu, Seoul 05006, Republic of Korea.
| |
Collapse
|
100
|
Liigand J, de Vries R, Cuyckens F. Optimization of flow splitting and make-up flow conditions in liquid chromatography/electrospray ionization mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2019; 33:314-322. [PMID: 30440111 DOI: 10.1002/rcm.8352] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Revised: 11/09/2018] [Accepted: 11/09/2018] [Indexed: 06/09/2023]
Abstract
RATIONALE In liquid chromatography/mass spectrometry (LC/MS) the LC flow is often split prior to the mass spectrometer, for instance, when collecting fractions of the separated sample for other purposes or when less sensitive parallel detection is applied. The aim of this study is to optimize the actual split ratio and make-up flow composition. METHODS Different types of splitters were evaluated in combination with a make-up flow. A home-made 1/10 T-piece splitter and commercial 1/10, 1/100 and 1/250 splitters were evaluated by continuous and accurate measurements of the actual split ratio throughout the LC gradient. The make-up flow composition was optimized for maximum electrospray ionization (ESI)-MS sensitivity in the positive mode using ESI efficiency measurements. RESULTS Altogether 22 different solvent conditions were tested on 20 pharmaceutical compounds with a wide variety of functional groups and physicochemical properties (molecular weight, logP, and pKa ). Methanol/10 mM formic acid in water (90/10) provided on average the best results. CONCLUSIONS Methanol/10 mM formic acid in water (90/10) proved to be the best make-up flow composition in relation to the average sensitivity obtained. Stronger acidic conditions using oxalic acid or higher formic acid concentrations had a clear positive effect on the sensitivity of compounds with low ionization efficiency. The tested split ratios were relatively stable over the main part of the gradient but showed some variation at very low and very high organic conditions. Differences were larger with methanol compared with acetonitrile containing solvent compositions and when applied without a column or with very long connecting tubing.
Collapse
Affiliation(s)
- Jaanus Liigand
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Ronald de Vries
- Discovery Sciences, Janssen Research and Development, Turnhoutseweg 30, B-2340, Beerse, Belgium
| | - Filip Cuyckens
- Discovery Sciences, Janssen Research and Development, Turnhoutseweg 30, B-2340, Beerse, Belgium
| |
Collapse
|