51
|
Bamberg F, Abbara S, Schlett CL, Cury RC, Truong QA, Rogers IS, Nagurney JT, Brady TJ, Hoffmann U. Predictors of image quality of coronary computed tomography in the acute care setting of patients with chest pain. Eur J Radiol 2009; 74:182-8. [PMID: 19346094 DOI: 10.1016/j.ejrad.2009.03.001] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2008] [Revised: 02/26/2009] [Accepted: 03/03/2009] [Indexed: 11/17/2022]
Abstract
OBJECTIVE We aimed to determine predictors of image quality in consecutive patients who underwent coronary computed tomography (CT) for the evaluation of acute chest pain. METHOD AND MATERIALS We prospectively enrolled patients who presented with chest pain to the emergency department. All subjects underwent contrast-enhanced 64-slice coronary multi-detector CT. Two experienced readers determined overall image quality on a per-patient basis and the prevalence and characteristics of non-evaluable coronary segments on a per-segment basis. RESULTS Among 378 subjects (143 women, age: 52.9+/-11.8 years), 345 (91%) had acceptable overall image quality, while 33 (9%) had poor image quality or were unreadable. In adjusted analysis, patients with diabetes, hypertension and a higher heart rate during the scan were more likely to have exams graded as poor or unreadable (odds ratio [OR]: 2.94, p=0.02; OR: 2.62, p=0.03; OR: 1.43, p=0.02; respectively). Of 6253 coronary segments, 257 (4%) were non-evaluable, most due to severe calcification in combination with motion (35%). The presence of non-evaluable coronary segments was associated with age (OR: 1.08 annually, 95%-confidence interval [CI]: 1.05-1.12, p<0.001), baseline heart rate (OR: 1.35 per 10 beats/min, 95%-CI: 1.11-1.67, p=0.003), diabetes, hypertension, and history of coronary artery disease (OR: 4.43, 95%-CI: 1.93-10.17, p<0.001; OR: 2.27, 95-CI: 1.01-4.73, p=0.03; OR: 5.12, 95%-CI: 2.0-13.06, p<0.001; respectively). CONCLUSION Coronary CT permits acceptable image quality in more than 90% of patients with chest pain. Patients with multiple risk factors are more likely to have impaired image quality or non-evaluable coronary segments. These patients may require careful patient preparation and optimization of CT scanning protocols.
Collapse
Affiliation(s)
- Fabian Bamberg
- Cardiac MR PET CT Program, Department of Radiology and Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, United States
| | | | | | | | | | | | | | | | | |
Collapse
|
52
|
Image Quality in a Low Radiation Exposure Protocol for Retrospectively ECG-Gated Coronary CT Angiography. AJR Am J Roentgenol 2009; 192:1045-50. [DOI: 10.2214/ajr.08.1025] [Citation(s) in RCA: 107] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
53
|
Dikkers R, Greuter M, Kristanto W, van Ooijen P, Sijens P, Willems T, Oudkerk M. Assessment of image quality of 64-row Dual Source versus Single Source CT coronary angiography on heart rate: A phantom study. Eur J Radiol 2009; 70:61-8. [DOI: 10.1016/j.ejrad.2008.01.011] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2007] [Revised: 01/11/2008] [Accepted: 01/14/2008] [Indexed: 10/22/2022]
|
54
|
[Dual-source CT coronary angiography: image quality and optimal reconstruction interval]. RADIOLOGIA 2009; 51:376-84. [PMID: 19282012 DOI: 10.1016/j.rx.2008.11.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2008] [Accepted: 06/12/2008] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To evaluate the effect of average heart rate on the quality of images of the coronary arteries and to determine the optimal reconstruction interval in nonselected patients undergoing DSCT coronary imaging. MATERIALS AND METHODS We studied 28 consecutive subjects (26 men, 2 women; mean age 60+/-12 years) undergoing contrast-enhanced DSCT (Somatom Definition, Siemens) coronary angiography. Data sets were reconstructed in 5% steps from 30% to 80% of the R-R interval. Two blinded independent readers assessed the image quality of the whole coronary tree and of each coronary artery using a four-point scale (1: impossible to evaluate, 4: excellent quality). RESULTS Mean heart rate during scanning was 73.1+/-14.8 bpm (range, 49-107 bpm). In the best reconstruction interval, excellent diagnostic image quality (score 4) was achieved for 98.8% (83/84) of coronary arteries. Very good interobserver agreement was observed for image quality rating (kappa=0.77) and for selection of the optimal reconstruction interval (kappa=0.86). Mean image quality score for the whole coronary tree was 2.84+/-0.31. No significant correlation was found between the average heart rate and the mean quality scores (r=0.108). No significant differences were found in the quality of images of the coronary arteries in systolic and diastolic reconstructions in each patient. CONCLUSIONS DSCT makes it possible to obtain excellent coronary angiograms independent of the heart rate. Reconstructions can be obtained in either the diastolic or systolic phase without significant differences in image quality, even at high heart rates.
Collapse
|
55
|
Meta-analysis of 40- and 64-MDCT angiography for assessing coronary artery stenosis. AJR Am J Roentgenol 2009; 191:1667-75. [PMID: 19020234 DOI: 10.2214/ajr.07.4022] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of our study was to assess the diagnostic performance of thin-slice (< or = 0.625 mm) MDCT coronary angiography compared with invasive coronary angiography for the detection of significant (> or = 50%) stenosis. MATERIALS AND METHODS Twenty-two articles on 40- and 64-MDCT coronary angiography were included. Sensitivity and specificity were calculated on a per-patient and per-segment basis; in addition, proximal versus distal segments were evaluated. The effect of nonevaluable patients, nonevaluable segments, and disease prevalence on diagnostic performance was assessed. RESULTS Pooled sensitivity on a patient level was 97.7% ([95% CI] 96.2-98.7%) and specificity 91.0% (88.5-93.1%). Pooled sensitivity on a segmental level was 90.8% (89.0-92.4%) and specificity 95.7% (95.2-96.1%); for proximal segments, respectively, 94.2% (92.3-95.7%) and 94.1% (93.4-94.8%), and for distal segments 84.8% (81.1-88.0%) and 96.9% (96.4-97.4%). If nonevaluable MDCT investigations were included, the per-patient specificity was reduced from 91.0% to 89.1% (p > 0.05) when allocating excluded patients as having significant coronary artery stenosis, and the sensitivity was reduced from 97.7% to 96.2% (p > 0.05) when allocating excluded patients as not having significant stenosis. The per-patient prevalence of coronary artery stenosis had no significant influence on the sensitivity for detecting significant stenosis. CONCLUSION Forty- and 64-MDCT provide good-to-excellent performance in detecting or ruling out significant coronary artery stenosis, with better results for proximal than for distal coronary artery segments.
Collapse
|
56
|
Abstract
OBJECTIVE The aim of this study was to assess three different phase-selection methods for obtaining optimal CT coronary artery image quality. MATERIALS AND METHODS ECG-gated CT coronary angiography scans of 40 patients (23 men, 17 women; mean age, 56 years) were retrieved. The patient group was composed of 20 consecutive patients with heart rates < or = 65 beats per minute (bpm) and 20 consecutive patients with heart rates > 65 bpm. Three phase-selection methods were evaluated: fixed phase selection, manual phase selection, and automated phase selection. Two scoring systems were used to evaluate diagnostic quality: scoring of axial images on a 5-point scale and scoring of multiplanar reconstructions (MPRs) on a forced-choice 3-point preference scale. Differences were tested by Wilcoxon's signed rank test for the entire patient group and the two subgroups including patients with heart rates < or = 65 bpm and those with heart rates > 65 bpm. RESULTS Axial image evaluation of the entire patient group showed statistically significant superior image quality for the manual phase-selection method compared with the predefined phase-selection method and no statistically significant differences were found for the other comparisons. Analysis at heart rates < or = 65 bpm showed no significant differences between phase-selection methods. Analysis at heart rates > 65 bpm showed the best results for the automated phase-selection method, and image quality was significantly better for the automated and manual phase-selection methods than for the predefined phase-selection method. CONCLUSION The automated phase-selection method accurately detects the optimal diagnostic phase for CT coronary artery evaluation and has the potential to reduce operator time needed for image reconstruction.
Collapse
|
57
|
Herzog BA, Husmann L, Burkhard N, Valenta I, Gaemperli O, Tatsugami F, Wyss CA, Landmesser U, Kaufmann PA. Low-dose CT coronary angiography using prospective ECG-triggering: impact of mean heart rate and heart rate variability on image quality. Acad Radiol 2009; 16:15-21. [PMID: 19064207 DOI: 10.1016/j.acra.2008.06.010] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2008] [Revised: 06/11/2008] [Accepted: 06/12/2008] [Indexed: 11/18/2022]
Abstract
RATIONALE AND OBJECTIVES The aim of this study was to evaluate the effect of mean heart rate (HR) and HR variability on image quality in low-dose computed tomographic coronary angiography (CTCA) using prospective electrocardiographic (ECG) triggering. MATERIALS AND METHODS One hundred thirty-six consecutive patients were scheduled for low-dose CTCA using prospective ECG triggering. The image quality of all coronary segments was rated on a 5-point scale by two independent readers (scores of 1-3 were considered diagnostic, and scores of 4 and 5 were considered nondiagnostic). Intravenous beta blockers were administered targeting HR < 65 beats/min before scanning, but not if HR increased during scanning. RESULTS After the exclusion of seven patients because of arrhythmia (n = 4) or mean HRs > 65 beats/min despite using beta blockers (n = 3), 129 patients underwent computed tomographic scanning. The estimated mean effective radiation dose was 2.2 +/- 0.7 mSv (range, 1.1-3.5). The mean HR during scanning was 58.4 +/- 6.6 beats/min (range, 44.2-80.1), with a variability of 1.6 +/- 1.0 beats/min (range, 0.2-5.3). Mean HR (r = 0.49, P < .001) but not mean HR variability (r = 0.14) was related to image quality. Nondiagnostic image quality on CTCA was found in 5% of the coronary segments in 21 of 129 patients. However, on receiver-operating characteristic analysis, a cutoff HR of 62 beats/min was determined, below which nondiagnostic segments were significantly less frequent (2% vs 14%, P < .001). CONCLUSION Prospective triggering allows low-dose CTCA but requires a low HR. Because a low HR offers a prolonged diastole, widening the optimal phase for scanning, HR variability seems to have a negligible impact on image quality.
Collapse
Affiliation(s)
- Bernhard A Herzog
- Cardiovascular Center, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland
| | | | | | | | | | | | | | | | | |
Collapse
|
58
|
Nagao M, Matsuoka H, Kawakami H, Higashino H, Mochizuki T, Ohshita A, Kohno T, Shigemi S. Detection of Myocardial Ischemia Using 64-Slice MDCT. Circ J 2009; 73:905-11. [PMID: 19325193 DOI: 10.1253/circj.cj-08-0940] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Michinobu Nagao
- Department of Radiology, Ehime University Graduate School of Medicine
| | | | - Hideo Kawakami
- Departments of Cardiology, Prefectural Ehime Imabari Hospital
| | - Hiroshi Higashino
- Department of Radiology, Ehime University Graduate School of Medicine
| | | | - Akira Ohshita
- Departments of Cardiology, Prefectural Ehime Imabari Hospital
| | - Tamami Kohno
- Departments of Cardiology, Prefectural Ehime Imabari Hospital
| | - Susumu Shigemi
- Departments of Cardiology, Prefectural Ehime Imabari Hospital
| |
Collapse
|
59
|
Rieber J, Sheth TN, Mooyaart EAQ, Shapiro MD, Butler J, Ferencik M, Brady TJ, Klauss V, Hoffmann U. Assessment of the presence and extent of coronary collateralization by coronary computed tomographic angiography in patients with total occlusions. Int J Cardiovasc Imaging 2008; 25:331-7. [DOI: 10.1007/s10554-008-9384-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2008] [Accepted: 10/24/2008] [Indexed: 10/21/2022]
|
60
|
Herzog BA, Husmann L, Burkhard N, Gaemperli O, Valenta I, Tatsugami F, Wyss CA, Landmesser U, Kaufmann PA. Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience. Eur Heart J 2008; 29:3037-42. [PMID: 18996954 DOI: 10.1093/eurheartj/ehn485] [Citation(s) in RCA: 111] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
AIMS To evaluate the accuracy of low-dose computed tomography coronary angiography (CTCA) using prospective ECG-triggering for the assessment of coronary artery disease (CAD). METHODS AND RESULTS A total of 30 patients (19 males, 11 females, mean age 58.8 +/- 9.9 years) underwent low-dose CTCA and invasive coronary angiography (CA) [median 2 days (0, 41)]. Before CT scanning, intravenous beta-blocker was administered in 18 of 30 patients as heart rate (HR) was >65 b.p.m., achieving a mean HR of 55.7 +/- 7.9 b.p.m. CAD was defined as coronary artery narrowing > or =50%, using CA as standard of reference. The estimated mean effective radiation dose was 2.1 +/- 0.7 mSv (range: 1.0-3.3), yielding 96.0% (383/399) of evaluable segments. On an intention-to-diagnose-base, all non-evaluative segments were included in the analysis. Vessels with a non-evaluative segment and no further finding were censored as false positive. Patient-based analysis revealed sensitivity, specificity, positive predictive value, and negative predictive value of 100, 83.3, 90.0, and 100%, respectively. The respective values per vessel were 100, 88.9, 85.7, and 100%, respectively. CONCLUSION Prospective ECG-triggering allows low-dose CTCA and provides high diagnostic accuracy in the assessment of CAD in patients with stable sinus rhythm and a low heart rate.
Collapse
Affiliation(s)
- Bernhard A Herzog
- Cardiovascular Center, Raemistrasse 100, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland
| | | | | | | | | | | | | | | | | |
Collapse
|
61
|
Burgstahler C, Reimann A, Brodoefel H, Daferner U, Herberts T, Tsiflikas I, Thomas C, Drosch T, Schroeder S, Heuschmid M. Quantitative parameters to compare image quality of non-invasive coronary angiography with 16-slice, 64-slice and dual-source computed tomography. Eur Radiol 2008; 19:584-90. [PMID: 18953544 DOI: 10.1007/s00330-008-1201-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2008] [Revised: 09/11/2008] [Accepted: 09/21/2008] [Indexed: 11/25/2022]
|
62
|
Heffernan EJ, Dodd JD, Malone DE. Cardiac Multidetector CT: Technical and Diagnostic Evaluation with Evidence-based Practice Techniques. Radiology 2008; 248:366-77. [DOI: 10.1148/radiol.2482070356] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
63
|
Dual-source CT coronary imaging in heart transplant recipients: image quality and optimal reconstruction interval. Eur Radiol 2008; 18:1791-9. [DOI: 10.1007/s00330-008-0957-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2007] [Revised: 02/15/2008] [Accepted: 02/25/2008] [Indexed: 11/27/2022]
|
64
|
Leschka S, Stolzmann P, Schmid FT, Scheffel H, Stinn B, Marincek B, Alkadhi H, Wildermuth S. Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose. Eur Radiol 2008; 18:1809-17. [PMID: 18392829 DOI: 10.1007/s00330-008-0966-1] [Citation(s) in RCA: 218] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2007] [Revised: 02/04/2008] [Accepted: 03/05/2008] [Indexed: 12/20/2022]
Abstract
The purpose of this study was to investigate the effect of low kilovoltage dual-source computed tomography coronary angiography (CTCA) on qualitative and quantitative image quality parameters and radiation dose. Dual-source CTCA with retrospective ECG gating was performed in 80 consecutive patients of normal weight. Forty were examined with a standard protocol (120 kV/330mAs), 20 were examined at 100 kV/330mAs, and 20 at 100 kV/220mAs. Two blinded observers independently assessed image quality of each coronary segment and measured the image parameters noise, attenuation, and contrast-to-noise ratio (CNR). The effective radiation dose was calculated using CT dose volume index and the dose-length product. Diagnostic image quality was obtained in 99% of all coronary segments (1,127/1,140) without significant differences among the protocols. Image noise, attenuation, and CNR were significantly higher for 100 kV/330mAs (26 +/- 3 HU, 549 +/- 62 HU, 25.5 +/- 3.2; each P < 0.01) and 100 kV/220mAs (27 +/- 2 HU, 560 +/- 43 HU, 25.0 +/- 2.2; each P < 0.01) when compared to the 120-kV protocol (21 +/- 2 HU, 317 +/- 28 HU, 20.6 +/- 1.7). There was no significant difference between the two 100-kV protocols. Estimated effective radiation dose of the 120-kV protocol (8.9 +/- 1.2 mSv) was significantly higher than the 100 kV/330mAs (6.7 +/- 0.8 mSv, P < 0.01) or 100 kV/220mAs (4.4 +/- 0.6 mSv, P < 0.001) protocols. Dual-source CTCA with 100 kV is feasible in patients of normal weight, results in a diagnostic image quality with a higher CNR, and at the same time significantly reduces the radiation dose.
Collapse
Affiliation(s)
- Sebastian Leschka
- Institute of Radiology, Kantonsspital St. Gallen, St. Gallen, Switzerland
| | | | | | | | | | | | | | | |
Collapse
|
65
|
Brodoefel H, Reimann A, Burgstahler C, Schumacher F, Herberts T, Tsiflikas I, Schroeder S, Claussen CD, Kopp AF, Heuschmid M. Noninvasive coronary angiography using 64-slice spiral computed tomography in an unselected patient collective: Effect of heart rate, heart rate variability and coronary calcifications on image quality and diagnostic accuracy. Eur J Radiol 2008; 66:134-41. [PMID: 17600648 DOI: 10.1016/j.ejrad.2007.05.013] [Citation(s) in RCA: 75] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2006] [Revised: 05/14/2007] [Accepted: 05/16/2007] [Indexed: 11/28/2022]
Abstract
OBJECTIVE The aim of this study was to assess the impact of heart rate, heart rate variability and calcification on image quality and diagnostic accuracy in an unselected patient collective. SUBJECTS AND METHODS One hundred and two consecutive patients with known or suspected coronary artery disease underwent both 64-MSCT and invasive coronary angiography. Image quality (IQ) was assessed by independent observers using a 4-point scale from excellent (1) to non-diagnostic (4). Accuracy of MSCT regarding detection or exclusion of significant stenosis (>50%) was evaluated on a per segment basis in a modified AHA 13-segment model. Effects of heart rate, heart rate variability, calcification and body mass index (BMI) on IQ and accuracy were evaluated by multivariate regression. IQ and accuracy were further analysed in subgroups of significant predictor variables and simple regression performed to calculate thresholds for adequate IQ. RESULTS Mean heart rate was 68.2+/-13.3 bpm, mean heart rate variability 11.5+/-16.0 beats per CT-examination (bpct) and median Agatston score 226.5. Average IQ score was 2+/-0.6 whilst diagnostic quality was obtained in 89% of segments. Overall sensitivity, specificity, PPV or NPV was 91.2%, 99.2%, 95.3% or 98.3%. According to multivariate regression, overall IQ was significantly related to heart rate and calcification (P=0.0038; P<0.0001). The effect of heart rate variability was limited to IQ of RCA segments (P=0.018); BMI was not related to IQ (P=0.52). Calcification was the only predictor variable with significant effect on the number of non-diagnostic segments (P<0.0001). In a multivariate regression, calcification was also the single factor with impact on diagnostic accuracy (P=0.0049). CONCLUSION Whilst heart rate, heart rate variability and calcification all show an inverse correlation to IQ, severe calcium burden remains the single factor with translation of such effect into decrease of diagnostic accuracy.
Collapse
Affiliation(s)
- H Brodoefel
- Department of Diagnostic Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str. 3, 72076 Tübingen, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
66
|
Moloo J, Shapiro MD, Abbara S. Cardiac Computed Tomography: Technique and Optimization of Protocols. Semin Roentgenol 2008; 43:90-9. [DOI: 10.1053/j.ro.2008.01.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
67
|
Brodoefel H, Burgstahler C, Tsiflikas I, Reimann A, Schroeder S, Claussen CD, Heuschmid M, Kopp AF. Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy. Radiology 2008; 247:346-55. [PMID: 18372455 DOI: 10.1148/radiol.2472070906] [Citation(s) in RCA: 180] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
PURPOSE To prospectively evaluate the effect of heart rate, heart rate variability, and calcification on dual-source computed tomography (CT) image quality and to prospectively assess diagnostic accuracy of dual-source CT for coronary artery stenosis, by using invasive coronary angiography as the reference standard. MATERIALS AND METHODS This study had local Ethics Committee approval; all patients gave informed consent. Patients who underwent bypass surgery were excluded; patients with coronary artery stent-grafts were included. One hundred patients (20 women, 80 men; mean age, 62 years +/- 10 [standard deviation]) known to have or suspected of having coronary artery disease underwent dual-source CT and invasive coronary angiography. Image quality was assessed. Accuracy of dual-source CT in depiction or exclusion of significant stenosis (>or=50%) was evaluated on a per-segment and per-patient basis. Effects of heart rate, heart rate variability, and calcification on image quality and accuracy were analyzed by using multivariate regression and were analyzed between subgroups of predictor variables. Simple regression was performed to calculate thresholds for adequate image quality. RESULTS Mean heart rate was 64.9 beats per minute +/- 13.2, mean variability was 23.6 beats per CT examination +/- 36.2, and mean Agatston score was 786.5 +/- 965.9. Diagnostic image quality was obtained in 90.2% of segments. Sensitivity, specificity, and positive and negative predictive values for the presence of significant stenosis were, respectively, 91.1%, 92.0%, 75.4%, and 97.5% by segment and 100%, 81.5%, 93.6%, and 100% by patient. Image quality was significantly related to heart rate variability (P = .015) and calcification (P < .001); the number of nondiagnostic segments was significantly affected by calcification only. Calcification was the single factor with significant impact on diagnostic accuracy (P = .001). CONCLUSION While dual-source CT resulted in heart-rate independent image quality, image quality remained prone to heart rate variability and calcification.
Collapse
Affiliation(s)
- Harald Brodoefel
- Department of Diagnostic Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str 3, 72076 Tübingen, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
68
|
Dewey M, Rutsch W, Hamm B. Is there a gender difference in noninvasive coronary imaging? Multislice computed tomography for noninvasive detection of coronary stenoses. BMC Cardiovasc Disord 2008; 8:2. [PMID: 18230167 PMCID: PMC2268658 DOI: 10.1186/1471-2261-8-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2007] [Accepted: 01/29/2008] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND Multislice computed tomography (MSCT) coronary angiography is the foremost alternative to invasive coronary angiography. METHODS We sought to compare the diagnostic accuracy of MSCT in female and male patients with suspected coronary disease. Altogether 50 women and 95 men underwent MSCT with 0.5 mm detector collimation. Coronary artery stenoses of at least 50% on conventional coronary angiography were considered significant. RESULTS The coronary vessel diameters of all four main coronary artery branches were significantly larger in men than in women. The diagnostic accuracy of MSCT in identifying patients with coronary artery disease was significantly lower for women (72%) compared with men (89%, p < 0.05). Also sensitivity (70% vs. 95%), positive predictive value (64% vs. 93%), and the rate of nondiagnostic examinations (14% vs. 4%, all: p < 0.05) were significantly worse for women. The effective radiation dose of MSCT coronary angiography was significantly higher in the examination of women (13.7 +/- 1.2 mSv) than of men (11.7 +/- 0.9 mSv, p < 0.001), mainly as a result of the fact that the radiosensitive female breast (contributing 24.5% of the dose in women) is in the x-ray path. CONCLUSION Noninvasive coronary angiography with MSCT might be less accurate and sensitive for women than men. Also, women are exposed to a significantly higher effective radiation dose than men.
Collapse
Affiliation(s)
- Marc Dewey
- Department of Radiology, Charité, Medical School, Humboldt-Universität zu Berlin, Germany
| | - Wolfgang Rutsch
- Department of Cardiology, Charité, Medical School, Humboldt-Universität zu Berlin, Germany
| | - Bernd Hamm
- Department of Radiology, Charité, Medical School, Humboldt-Universität zu Berlin, Germany
| |
Collapse
|
69
|
Greil GF, Boettger T, Germann S, Klumpp B, Baltes C, Kozerke S, Bialkowski A, Urschitz MS, Miller S, Wolf I, Meinzer HP, Sieverding L. Quantitative assessment of ventricular function using three-dimensional SSFP magnetic resonance angiography. J Magn Reson Imaging 2007; 26:288-95. [PMID: 17654727 DOI: 10.1002/jmri.20967] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
PURPOSE To evaluate three-dimensional (3D), free-breathing, steady-state free precession (SSFP) magnetic resonance angiography (MRA) for volumetric assessment of ventricular function. MATERIALS AND METHODS In 18 subjects (mean age = 21.5 years) 3D datasets of the heart and great vessels were acquired using an ECG-triggered, free-breathing SSFP technique with a T2-preparation prepulse. Data were acquired during end-systole (ES) and end-diastole (ED) for assessment of stroke volumes (SVs). Through-plane flow measurements of the great arteries were performed as well as 2D-cine SSFP imaging for comparison. For image analysis of the 3D SSFP datasets a simplex mesh model was used. Papillary muscles were excluded from ventricular volumes using thresholds. Intra- and interobserver variability (Bland-Altman analysis) and correlations (Pearson's coefficient) between volumetric and flow measurements were assessed. RESULTS ES and ED datasets were acquired successfully in all subjects. The best correlation was observed between flow vs. 3D SSFP SV for the LV (r = 0.85, mean difference = -1.0 mL) and the RV (r = 0.89, mean difference = -2.2 mL) with high intra- (LV: r = 0.93; RV: r = 0.94) and interobserver (LV: r = 0.91; RV: r = 0.93) reproducibility. CONCLUSION 3D SSFP datasets combined with semiautomatic segmentation algorithms allow highly accurate and reproducible assessment of left (LV) and right ventricular (RV) SVs in free-breathing subjects.
Collapse
Affiliation(s)
- Gerald F Greil
- Department of Pediatric Cardiology, Children's Hospital, University of Tuebingen, Tuebingen, Germany.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
70
|
Dewey M, Teige F, Rutsch W, Schink T, Hamm B. CT coronary angiography: influence of different cardiac reconstruction intervals on image quality and diagnostic accuracy. Eur J Radiol 2007; 67:92-9. [PMID: 17766074 DOI: 10.1016/j.ejrad.2007.07.012] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2007] [Accepted: 07/25/2007] [Indexed: 11/27/2022]
Abstract
PURPOSE To prospectively analyze image quality and diagnostic accuracy of different reconstruction intervals of coronary angiography using multislice computed tomography (MSCT). MATERIALS AND METHODS For each of 47 patients, 10 ECG-gated MSCT reconstructions were generated throughout the RR interval from 0 to 90%, resulting in altogether 470 datasets. These datasets were randomly analyzed for image quality and accuracy and compared with conventional angiography. Statistical comparison of intervals was performed using nonparametric analysis for repeated measurements to account for clustering of arteries within patients. RESULTS Image reconstruction intervals centered at 80, 70, and 40% of the RR interval resulted (in that order) in the best overall image quality for all four main coronary vessels. Eighty percent reconstructions also yielded the highest diagnostic accuracy of all intervals. The combination of the three best intervals (80, 70, and 40%) significantly reduced the nondiagnostic rate as compared with 80% alone (p=0.005). However, the optimal reconstruction interval combination achieved significantly improved specificities and nondiagnostic rates (p<0.05). The optimal combination consisted of 1.7+/-0.9 reconstruction intervals on average. In approximately half of the patients (49%, 23/47) a single reconstruction was optimal. In 18 (38%), 3 (6%), and 3 (6%) patients one, two, and three additional reconstruction intervals were required, respectively, to achieve optimal quality. In 28% of the patients the optimal combination consisted of reconstructions other than the three best intervals (80, 70, and 40%). CONCLUSION Multiple image reconstruction intervals are essential to ensure high image quality and accuracy of CT coronary angiography.
Collapse
Affiliation(s)
- Marc Dewey
- Department of Radiology, Charité Medical School, Humboldt-Universität zu Berlin, Germany.
| | | | | | | | | |
Collapse
|
71
|
Onuma Y, Tanabe K, Chihara R, Yamamoto H, Miura Y, Kigawa I, Fukuda S, Miyairi T, Nakajima H, Hara K. Evaluation of coronary artery bypass grafts and native coronary arteries using 64-slice multidetector computed tomography. Am Heart J 2007; 154:519-26. [PMID: 17719300 DOI: 10.1016/j.ahj.2007.04.054] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2006] [Accepted: 04/29/2007] [Indexed: 12/01/2022]
Abstract
BACKGROUND The conventional use of 16-slice multidetector computed tomography (MDCT) remains somewhat limited for evaluating stenoses in vein graft distal anastomotic sites and in coronary arteries. We investigated the diagnostic accuracy of 64-slice MDCT for assessment of both grafts and coronary arteries in patients with coronary artery bypass grafts. METHOD The study group included 54 consecutive patients. One patient had to be excluded from the study because of arrhythmia. The remaining 53 patients with coronary artery bypass grafts underwent both 64-slice MDCT angiography and invasive coronary angiography. The MDCTs were analyzed for presence of significant stenosis (>50%) or occlusion in grafts and coronary arteries. The results were compared with those of invasive coronary angiography. RESULTS Overall, 138 of 146 (94.5%) grafts including distal anastomoses were evaluable with MDCT. Evaluability of arterial grafts, venous grafts, distal runoff arteries, and nongrafted arteries was 90.3%, 98.6%, 84.0%, and 97.3%, respectively. After censoring nonevaluable grafts or arteries and considering them to be positive, the sensitivity to detect significant stenosis or occlusion in arterial grafts was 100% and specificity was 91.4%. In venous graft, sensitivity was 100% and specificity was 98.1%. In distal runoff arteries, sensitivity to detect significant stenoses was 83.3% and specificity was 80.2%. In nongrafted arteries, sensitivity was 100% and specificity was 87.5%. CONCLUSIONS Sixty-four-slice MDCT showed improved ability to assess bypass grafts and coronary arteries. However, there were still difficulties in assessment of distal runoff arteries in which relatively low diagnostic accuracy was observed that might limit clinical implementation of MDCT.
Collapse
Affiliation(s)
- Yoshinobu Onuma
- Division of Cardiology, Mitsui Memorial Hospital, Tokyo, Japan
| | | | | | | | | | | | | | | | | | | |
Collapse
|
72
|
Kroft LJM, de Roos A, Geleijns J. Artifacts in ECG-Synchronized MDCT Coronary Angiography. AJR Am J Roentgenol 2007; 189:581-91. [PMID: 17715104 DOI: 10.2214/ajr.07.2138] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
OBJECTIVE In MDCT coronary angiography, image artifacts are the major cause of false-positive and false-negative interpretations regarding the presence of coronary artery stenoses. Hence, it is important that observers reporting these investigations are aware of the potential presence of image artifacts and that these artifacts are recognized. CONCLUSION The article explores the technical causes for various artifacts in MDCT coronary angiography imaging and clinical examples are given.
Collapse
Affiliation(s)
- L J M Kroft
- Department of Radiology, C2S, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.
| | | | | |
Collapse
|
73
|
Busch S, Nikolaou K, Johnson T, Rist C, Knez A, Reiser M, Becker C. [Quantification of coronary artery stenoses: comparison of 64-slice and dual source CT angiography with cardiac catheterization]. Radiologe 2007; 47:295-300. [PMID: 17287946 DOI: 10.1007/s00117-007-1476-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
BACKGROUND Until now stenoses of the coronary arteries have been evaluated visually with CT angiography. Therefore, the results were highly dependent on subjective factors inherent in the examiner. New software tools for semiquantitative analysis (CT-QCA, quantitative coronary assessment) might be adequate to improve the diagnostic accuracy und reproducibility. MATERIAL AND METHODS CTAs of 20 patients were analyzed. Ten patients each were evaluated using 64-slice CT (64SCT) and dual source CT (DSCT) (Somatom Sensation 64 and Somatom Definition, Siemens Medical Solutions, Forchheim), respectively. Two radiologists independently evaluated the data visually and with the help of a software tool (Syngo Circulation, Siemens Medical Solutions, Forchheim). The results of the quantitative assessment of the invasive heart catheterization served as the reference standard. Sensitivity and specificity as well as the correlation coefficient, the systematic error, and the interobserver agreement (kappa) were determined. RESULTS In each of both patient groups 12 stenoses were detected. For the detection of stenoses >75%, sensitivity and specificity for the visual evaluation using the 64SCT were 100% and 90%, and with the CT-QCA both were 100%. For the DSCT sensitivity and specificity were 100% for both the visual and semiautomated evaluation. The Bland-Altman plot of the results of the 64SCT showed an overestimation of 3.3% (+/-62.7%/56.2%) compared to the heart catheterization. The results of the DSCT exhibited an overestimation of 6.2% (+/-33.1%/19.8%). The interobserver agreement of the CT-QCA and the visual evaluation showed a kappa value of 0.75 and for DSCT of 1.0. CONCLUSION The results showed a good correlation of grading stenosis between the software-assisted evaluation and the results of the coronary catheter angiography. The promising results of the DSCT are due to a superior temporal resolution compared to the 64SCT. Confirmation of these data by trials in larger patient collectives is warranted.
Collapse
Affiliation(s)
- Stephanie Busch
- Institut für Klinische Radiologie, Klinikum Grosshadern der Ludwig-Maximilians-Universität München, Marchioninistr. 15, 81377, München, Deutschland.
| | | | | | | | | | | | | |
Collapse
|
74
|
Leschka S, Scheffel H, Desbiolles L, Plass A, Gaemperli O, Valenta I, Husmann L, Flohr TG, Genoni M, Marincek B, Kaufmann PA, Alkadhi H. Image Quality and Reconstruction Intervals of Dual-Source CT Coronary Angiography. Invest Radiol 2007; 42:543-9. [PMID: 17620936 DOI: 10.1097/rli.0b013e31803b93cf] [Citation(s) in RCA: 126] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate reconstruction intervals and image quality in dual-source computed tomography (DSCT) coronary angiography for optimal placement of the ECG-pulsing window. MATERIALS AND METHODS DSCT coronary angiography was performed in 60 patients. Thirteen datasets were reconstructed in 5% increments from 20-80%. Two readers independently assessed image quality of each segment in each percentage-interval, using scores ranging from 1 (no motion artifacts) to 4 (nonevaluable). RESULTS Mean heart rate (HR) was 69.0 +/- 18.9 beats per minute (bpm) (range, 35-117 bpm). Diagnostic image quality (scores 1-3) was found in 97.8% of all segments (763 of 780). The 70% RR-interval provided best image quality in all patients and all HRs. The narrowest reconstruction window providing diagnostic image quality was 60-70% for HR <60 bpm, 60-80% for 60-70 bpm, 55-80% for 70-80 bpm, and 30-80% for HR >80 bpm. CONCLUSIONS DSCT coronary angiography provides best image quality for various HRs at 70%. The ECG-pulsing window can be adapted according to the HR while maintaining diagnostic image quality.
Collapse
Affiliation(s)
- Sebastian Leschka
- Institute of Diagnostic Radiology, University Hospital Zurich, Zurich, Switzerland
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
75
|
Greil GF, Seeger A, Miller S, Claussen CD, Hofbeck M, Botnar RM, Sieverding L. Coronary magnetic resonance angiography and vessel wall imaging in children with Kawasaki disease. Pediatr Radiol 2007; 37:666-73. [PMID: 17541574 DOI: 10.1007/s00247-007-0498-x] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2006] [Revised: 03/16/2007] [Accepted: 03/19/2007] [Indexed: 02/07/2023]
Abstract
BACKGROUND In patients with Kawasaki disease (KD) serial evaluation of the distribution and size of coronary artery aneurysms (CAA) is necessary for risk stratification and therapeutic management. OBJECTIVE To apply whole-heart coronary MR angiography (CMRA) and black-blood coronary vessel wall imaging in children with KD. MATERIALS AND METHODS Six children (mean age 4.6 years, range 2.5-7.8 years) with KD underwent CMRA using a free-breathing, T2-prepared, three-dimensional steady-state free-precession (3D-SSFP), whole-heart approach with navigator gating and tracking. Vessel walls were imaged with an ECG-triggered and navigator-gated double inversion recovery (DIR) black-blood segmented turbo spin-echo sequence. RESULTS There was complete agreement between CMRA and conventional angiography (n=6) in the detection of CAA (n=15). Excellent agreement was found between the two techniques in determining the maximal diameter (mean difference 0.2+/-0.7 mm), length (mean difference 0.1+/-0.8 mm) and distance from the ostium (mean difference -0.8+/-2.1 mm) of the CAAs. In all subjects with a CAA, abnormally thickened vessel walls were found (2.5+/-0.5 mm). CONCLUSIONS CMRA accurately defines CAA in free-breathing sedated children with KD using the whole-heart approach and detects abnormally thickened vessel walls. This technique may reduce the need for serial X-ray coronary angiography, and improve risk stratification and monitoring of therapy.
Collapse
Affiliation(s)
- Gerald F Greil
- Department of Pediatric Cardiology, Children's Hospital, University of Tuebingen, Hoppe Seyler Strasse 1, 72076 Tuebingen, Germany.
| | | | | | | | | | | | | |
Collapse
|
76
|
Langheinrich AC, Michniewicz A, Sedding DG, Lai B, Jorgensen SM, Bohle RM, Ritman EL. Quantitative X-ray imaging of intraplaque hemorrhage in aortas of apoE(-/-)/LDL(-/-) double knockout mice. Invest Radiol 2007; 42:263-73. [PMID: 17414521 DOI: 10.1097/01.rli.0000258085.87952.ea] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVES To determine if hemorrhage into an arterial wall can be detected in CT images by virtue of the iron content. MATERIALS AND METHODS Aortas from male apoE(-/-)/LDL(-/-) mice (n = 31) were infused in situ with contrast agent, for micro-CT scanning and histology. Roentgen-opacities within the aortic walls were identified by histology and micro-x-ray fluorescence to be iron or calcium. Dual-energy scanning was performed at 2 energy levels using synchrotron-based micro-CT [(2 microm)(3) voxels, 16 and 20 keV] and 64-slice CT (0.4 x 0.4 x 0.6 mm voxels, 80 and 120 kVp). RESULTS Opacities were identified as hemorrhage-related clusters of multiple punctate deposits, containing both Fe (0.48 x 10(-12) g/voxel) and Ca (3.18 x 10(-2) g/voxel), or as isolated confluent accumulations of exclusively calcium. Subtraction of the dual-energy CT scans discriminated iron from calcium deposits. CONCLUSION Detection and quantification of iron deposits in hemorrhaged atherosclerotic lesions is feasible by dual-energy CT imaging.
Collapse
Affiliation(s)
- Alexander C Langheinrich
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota 55905, USA
| | | | | | | | | | | | | |
Collapse
|
77
|
Effects of non-ionic iodinated contrast media on patient heart rate and pressures during intra-cardiac or intra-arterial injection. Int J Cardiol 2007; 118:389-96. [DOI: 10.1016/j.ijcard.2006.12.011] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2006] [Revised: 11/28/2006] [Accepted: 12/11/2006] [Indexed: 11/18/2022]
|
78
|
|
79
|
Rubinshtein R, Halon DA, Gaspar T, Jaffe R, Karkabi B, Flugelman MY, Kogan A, Shapira R, Peled N, Lewis BS. Usefulness of 64-slice cardiac computed tomographic angiography for diagnosing acute coronary syndromes and predicting clinical outcome in emergency department patients with chest pain of uncertain origin. Circulation 2007; 115:1762-8. [PMID: 17372178 DOI: 10.1161/circulationaha.106.618389] [Citation(s) in RCA: 243] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
BACKGROUND Multidetector computed tomography (MDCT) has high diagnostic value for detecting or excluding coronary artery stenosis. We examined performance characteristics of MDCT for diagnosing or excluding an acute coronary syndrome in patients presenting to the emergency department (ED) with possible ischemic chest pain and examined relation to clinical outcome during a 15-month follow-up period. METHODS AND RESULTS We prospectively studied 58 patients (56+/-10 years of age, 36% female) with chest pain possibly ischemic in origin and no new ECG changes or elevated biomarkers. The patients underwent 64-slice contrast-enhanced MDCT, which showed normal coronary vessels (no or trivial atheroma) in 15 patients, nonobstructive plaque in 20 (MDCT-negative patients), and obstructive coronary disease (> or = 50% luminal narrowing) in 23 (MDCT-positive group). By further investigation (new elevation of cardiac biomarkers, abnormal myocardial perfusion scintigraphy and/or invasive angiography), acute coronary syndrome was diagnosed in 20 of the 23 MDCT-positive patients (ED MDCT sensitivity 100% [20/20], specificity 92% [35/38], positive predictive value 87% [20/23], negative predictive value 100% [35/35]). During a 15-month follow-up period, no deaths or myocardial infarctions occurred in the 35 patients discharged from the ED after initial triage and MDCT findings. One patient underwent late percutaneous coronary intervention (late major adverse cardiovascular events rate, 2.8%). Overall, ED MDCT sensitivity for predicting major adverse cardiovascular events (death, myocardial infarction, or revascularization) during hospitalization and follow-up was 92% (12/13), specificity was 76% (34/45), positive predictive value was 52% (12/23), and negative predictive value was 97% (34/35). CONCLUSIONS We found that 64-slice cardiac MDCT is a potentially valuable diagnostic tool in ED patients with chest pain of uncertain origin, providing early direct noninvasive visualization of coronary anatomy. ED MDCT had high positive predictive value for diagnosing acute coronary syndrome, whereas a negative MDCT study predicted a low rate of major adverse cardiovascular events and favorable outcome during follow-up.
Collapse
Affiliation(s)
- Ronen Rubinshtein
- Department of Cardiovascular Medicine, Lady Davis Carmel Medical Center and the Ruth and Bruce Rappaport School of Medicine, Technion-Israel Institute of Technology, Haifa, Israel
| | | | | | | | | | | | | | | | | | | |
Collapse
|
80
|
Groen JM, Greuter MJW, van Ooijen PMA, Oudkerk M. A new approach to the assessment of lumen visibility of coronary artery stent at various heart rates using 64-slice MDCT. Eur Radiol 2007; 17:1879-84. [PMID: 17429648 PMCID: PMC1914269 DOI: 10.1007/s00330-006-0568-8] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2006] [Revised: 11/09/2006] [Accepted: 12/21/2006] [Indexed: 11/30/2022]
Abstract
Coronary artery stent lumen visibility was assessed as a function of cardiac movement and temporal resolution with an automated objective method using an anthropomorphic moving heart phantom. Nine different coronary stents filled with contrast fluid and surrounded by fat were scanned using 64-slice multi-detector computed tomography (MDCT) at 50–100 beats/min with the moving heart phantom. Image quality was assessed by measuring in-stent CT attenuation and by a dedicated tool in the longitudinal and axial plane. Images were scored by CT attenuation and lumen visibility and compared with theoretical scoring to analyse the effect of multi-segment reconstruction (MSR). An average increase in CT attenuation of 144 ± 59 HU and average diminished lumen visibility of 29 ± 12% was observed at higher heart rates in both planes. A negative correlation between image quality and heart rate was non-significant for the majority of measurements (P > 0.06). No improvement of image quality was observed in using MSR. In conclusion, in-stent CT attenuation increases and lumen visibility decreases at increasing heart rate. Results obtained with the automated tool show similar behaviour compared with attenuation measurements. Cardiac movement during data acquisition causes approximately twice as much blurring compared with the influence of temporal resolution on image quality.
Collapse
Affiliation(s)
- J. M. Groen
- Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30001, 9700 RB Groningen, The Netherlands
| | - M. J. W. Greuter
- Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30001, 9700 RB Groningen, The Netherlands
| | - P. M. A. van Ooijen
- Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30001, 9700 RB Groningen, The Netherlands
| | - M. Oudkerk
- Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30001, 9700 RB Groningen, The Netherlands
| |
Collapse
|
81
|
Wu YW, Tadamura E, Yamamuro M, Kanao S, Nakayama K, Togashi K. Evaluation of three-dimensional navigator-gated whole heart MR coronary angiography: The importance of systolic imaging in subjects with high heart rates. Eur J Radiol 2007; 61:91-6. [PMID: 16987631 DOI: 10.1016/j.ejrad.2006.08.013] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2006] [Revised: 08/04/2006] [Accepted: 08/04/2006] [Indexed: 10/24/2022]
Abstract
PURPOSE To evaluate the influence of heart rate (HR) on magnetic resonance coronary angiography (MRCA) image quality in diastolic and systolic phases. MATERIALS AND METHODS Twenty-seven healthy volunteers (9 men; 33+/-9 years, HR 53-110 bpm), were evaluated with the electrocardiography and three-dimensional navigator-gating MRCA in a 1.5-T MR scanner (Avanto, Siemens) in diastolic and systolic phases (steady-state free precession; TR/TE/flip angle=3.2 ms/1.6 ms/90 degrees). The timing of scanning was individually adapted to the cardiac rest periods obtained in the prescanning, by visually identifying when the movement of right coronary artery was minimized during diastole and systole. Images of two phases were side-by-side compared on a four-point scale (from 1=poor to 4=excellent visibility; score of 3 or 4 as diagnostic). RESULTS Of 13 subjects with HR < or =65 bpm (low HR group, mean 59.8+/-4.9 bpm, range 53-65), the image quality scores were significantly better than that with higher heart rates (73.9+/-9.0 bpm, range 68-110) in diastolic MRCA. The image quality was significantly improved during systole in high HR group. Overall, 91.3% of low HR group had MRCA image of diagnostic quality acquired at diastole, while 88.3% of high HR group had diagnostic images at systole by segmental analysis (p=NS). CONCLUSIONS MRCA at systole offered superior quality in patients with high heart rates.
Collapse
Affiliation(s)
- Yen-Wen Wu
- Department of Diagnostic Imaging, Kyoto University Graduate School of Medicine, 54 Shogoinkawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| | | | | | | | | | | |
Collapse
|
82
|
Busch S, Johnson TRC, Nikolaou K, von Ziegler F, Knez A, Reiser MF, Becker CR. Visual and automatic grading of coronary artery stenoses with 64-slice CT angiography in reference to invasive angiography. Eur Radiol 2006; 17:1445-51. [PMID: 17180326 DOI: 10.1007/s00330-006-0512-y] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2006] [Revised: 08/25/2006] [Accepted: 10/16/2006] [Indexed: 01/21/2023]
Abstract
The aim of this study was to assess the performance of a software tool for quantitative coronary artery analysis of computed tomography coronary angiography (CT-QCA) in comparison with invasive coronary angiography with quantitative analysis (CAG-QCA) as standard of reference. Two radiologists reviewed the CT angiography data sets (Siemens Sensation 64) of 25 patients, grading coronary artery stenoses visually and with a software tool (Circulation, Siemens). Twenty-three data sets with sufficient image quality were included in the final analysis. CAG revealed a total of 30 wall irregularities and 28 stenoses, of which 17 were graded as moderate and nine as hemodynamically significant. CT-QCA showed a better agreement to CAG-QCA, with a systematic overestimation of the degree of stenosis of 6.1% and limits of agreement of +36.1% and -23.9; the correlation coefficient was 0.82 (p < 0.0001). Using CT-QCA, sensitivity, specificity, and positive and negative predictive value were 89%, 100%, 89%, and 100%, respectively, for significant area stenoses greater than 75%. The positive predictive value for the visual assessment amounted to 53%. Interobserver variability between CT-QCA and visual assessment showed a kappa value of 0.72. In conclusion, software-supported CT-QCA makes it possible to quantify significant coronary artery stenoses automatically, with good agreement to CAG-QCA.
Collapse
Affiliation(s)
- Stephanie Busch
- Department of Clinical Radiology, University of Munich, Marchioninistr. 15, 81377 Munich, Germany.
| | | | | | | | | | | | | |
Collapse
|
83
|
Gregory SA, Ferencik M, Achenbach S, Yeh RW, Hoffmann U, Inglessis I, Cury RC, Nieman K, McNulty IA, Laffan JA, Pomerantsev EV, Brady TJ, Semigran MJ, Jang IK. Comparison of sixty-four-slice multidetector computed tomographic coronary angiography to coronary angiography with intravascular ultrasound for the detection of transplant vasculopathy. Am J Cardiol 2006; 98:877-84. [PMID: 16996866 DOI: 10.1016/j.amjcard.2006.04.027] [Citation(s) in RCA: 74] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2006] [Revised: 04/20/2006] [Accepted: 04/20/2006] [Indexed: 11/25/2022]
Abstract
Coronary allograft vasculopathy (CAV) is the most important limitation to long-term survival in adult heart transplant recipients and is difficult to detect without intravascular ultrasound (IVUS). We systematically evaluated the image quality of 64-slice multidetector computed tomographic (MDCT) coronary angiography in heart transplant recipients and tested the hypothesis that this modality is comparable to invasive coronary angiography with IVUS for the detection of CAV. Heart transplant recipients (n = 20) underwent invasive coronary angiography with IVUS and MDCT coronary angiography with a 64-slice scanner. Images were systematically analyzed for image quality and the presence of CAV. In addition, multidetector computed tomography and quantitative coronary angiography were used to measure lumen diameters at prespecified locations. Image quality analysis showed that, despite high mean heart rates (77 +/- 7 beats/min) and body mass index (29.5 +/- 5.3 kg/m(2)), 83% of coronary segments were graded as of excellent or good image quality. On average, 95 +/- 9% of the overall visualized length of the coronary arteries was imaged without motion artifacts, and the mean contrast-to-noise ratio was 11.3 +/- 4.6. Compared with IVUS, multidetector computed tomography had a sensitivity of 70%, specificity of 92%, positive predictive value of 89%, and negative predictive value of 77% for the detection of CAV. MDCT vessel diameter measurements correlated well with those obtained from quantitative coronary angiography (R(2) = 0.89). In conclusion, 64-slice multidetector computed tomography provides good to excellent image quality in heart transplant recipients and has moderate to excellent test characteristics for the detection of CAV. Further, MDCT measurements of lumen diameters correlated well with quantitative coronary angiography.
Collapse
Affiliation(s)
- Shawn A Gregory
- Cardiology Division, Department of Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|