1
|
Schnapauff D, Teige F, Hamm B, Dewey M. Comparison between the image quality of multisegment and halfscan reconstructions of non-invasive CT coronary angiography. Br J Radiol 2009; 82:969-75. [PMID: 19505967 DOI: 10.1259/bjr/27290085] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
The purpose of this study was to compare the image quality of multisegment and halfscan reconstructions of multislice computed tomography (MSCT) coronary angiography. 126 patients with suspected coronary artery disease and uninfluenced heart rates were examined by 16-slice CT before they underwent invasive coronary angiography. Multisegment and halfscan reconstructions were performed in all patients, and subjective image quality, overall vessel length, vessel length free of motion artefacts and contrast-to-noise ratios (CNRs) were compared for both techniques. The diagnostic accuracy of both approaches was compared with the results of invasive coronary angiography. Overall image quality scores of multisegment reconstruction were superior to those of halfscan reconstruction (13.3+/-2.1 vs 11.9+/-2.9; p<0.001). Multisegment reconstruction depicted significantly longer overall coronary vessel lengths (p<0.001) and larger vessel proportions free of motion artefacts in three of the four main coronary arteries. CNRs in the left main, left anterior descending and left circumflex coronary arteries were significantly higher when multisegment reconstruction was used (p<0.001). Overall accuracy was higher for multisegment reconstruction compared with halfscan reconstruction (87% vs 62%). In conclusion, multisegment reconstruction significantly improves image quality and diagnostic accuracy of MSCT coronary angiography compared with standard halfscan reconstruction, resulting in vessel lengths depicted free of motion comparable to those of CT performed in patients given beta-blockers to lower heart rates.
Collapse
Affiliation(s)
- D Schnapauff
- Department of Radiology, Charité - Universitätsmedizin Berlin, Freie Universität and Humboldt-Universität zu Berlin, Germany.
| | | | | | | |
Collapse
|
2
|
Dewey M, Teige F, Rutsch W, Schink T, Hamm B. CT coronary angiography: influence of different cardiac reconstruction intervals on image quality and diagnostic accuracy. Eur J Radiol 2007; 67:92-9. [PMID: 17766074 DOI: 10.1016/j.ejrad.2007.07.012] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2007] [Accepted: 07/25/2007] [Indexed: 11/27/2022]
Abstract
PURPOSE To prospectively analyze image quality and diagnostic accuracy of different reconstruction intervals of coronary angiography using multislice computed tomography (MSCT). MATERIALS AND METHODS For each of 47 patients, 10 ECG-gated MSCT reconstructions were generated throughout the RR interval from 0 to 90%, resulting in altogether 470 datasets. These datasets were randomly analyzed for image quality and accuracy and compared with conventional angiography. Statistical comparison of intervals was performed using nonparametric analysis for repeated measurements to account for clustering of arteries within patients. RESULTS Image reconstruction intervals centered at 80, 70, and 40% of the RR interval resulted (in that order) in the best overall image quality for all four main coronary vessels. Eighty percent reconstructions also yielded the highest diagnostic accuracy of all intervals. The combination of the three best intervals (80, 70, and 40%) significantly reduced the nondiagnostic rate as compared with 80% alone (p=0.005). However, the optimal reconstruction interval combination achieved significantly improved specificities and nondiagnostic rates (p<0.05). The optimal combination consisted of 1.7+/-0.9 reconstruction intervals on average. In approximately half of the patients (49%, 23/47) a single reconstruction was optimal. In 18 (38%), 3 (6%), and 3 (6%) patients one, two, and three additional reconstruction intervals were required, respectively, to achieve optimal quality. In 28% of the patients the optimal combination consisted of reconstructions other than the three best intervals (80, 70, and 40%). CONCLUSION Multiple image reconstruction intervals are essential to ensure high image quality and accuracy of CT coronary angiography.
Collapse
Affiliation(s)
- Marc Dewey
- Department of Radiology, Charité Medical School, Humboldt-Universität zu Berlin, Germany.
| | | | | | | | | |
Collapse
|
3
|
Dewey M, Teige F, Laule M, Hamm B. Influence of heart rate on diagnostic accuracy and image quality of 16-slice CT coronary angiography: comparison of multisegment and halfscan reconstruction approaches. Eur Radiol 2007; 17:2829-37. [PMID: 17639410 DOI: 10.1007/s00330-007-0685-z] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2006] [Revised: 04/06/2007] [Accepted: 05/08/2007] [Indexed: 10/23/2022]
Abstract
The lower the heart rate the better image quality in multislice computed tomography (MSCT) coronary angiography. We prospectively assessed the influence of heart rate on per-patient diagnostic accuracy and image quality of MSCT coronary angiography and compared adaptive multisegment and standard halfscan reconstruction. A consecutive cohort of 126 patients scheduled to undergo conventional coronary angiography was examined with 16-slice CT. For all heart rate groups, per-patient diagnostic accuracy was significantly higher for multisegment than halfscan reconstruction with values of 95 vs. 79% (p < 0.05, <65 bpm, 38 patients), 85 vs. 66% (p < 0.05, 65-74 bpm, 47 patients), and 78% vs. 41% (p < 0.001, >74 bpm, 41 patients). Differences in diagnostic accuracy between adjacent heart rate groups were only significant for halfscan reconstruction for the comparison between the 65-74 and >74 bpm group (p < 0.05). The vessel lengths free of motion artifacts were significantly longer with multisegment reconstruction in all heart rate groups and for all coronary arteries (p < 0.005). For noninvasive MSCT coronary angiography, both per-patient diagnostic accuracy and image quality decline with increasing heart rate, and multisegment reconstruction at high heart rates yields similar results as standard halfscan reconstruction at low heart rates.
Collapse
Affiliation(s)
- Marc Dewey
- Department of Radiology, Charité - Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Charitéplatz 1, P.O. Box 10098, 10117, Berlin, Germany.
| | | | | | | |
Collapse
|
4
|
|
5
|
Schönenberger E, Schnapauff D, Teige F, Laule M, Hamm B, Dewey M. Patient acceptance of noninvasive and invasive coronary angiography. PLoS One 2007; 2:e246. [PMID: 17327910 PMCID: PMC1796945 DOI: 10.1371/journal.pone.0000246] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2006] [Accepted: 01/27/2007] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Noninvasive angiography using multislice computed tomography (MSCT) is superior to magnetic resonance imaging (MRI) for detection of coronary stenoses. We compared patient acceptance of these two noninvasive diagnostic tests and invasive conventional coronary angiography (Angio). METHODS AND FINDINGS A total of 111 consecutive patients with suspected coronary artery disease underwent MSCT, MRI, and Angio. Subsequently, patient acceptance of the three tests was evaluated with questionnaires in all patients. The main acceptance variables were preparation and information prior to the test, degree of concern, comfort, degree of helplessness, pain (on visual analog scales), willingness to undergo the test again, and overall satisfaction. Preparation for each test was not rated significantly differently, whereas patients were significantly more concerned about Angio than the two noninvasive tests (p<0.001). No pain during MSCT, MRI, and Angio as assessed on visual analog scales (0 to 100) was reported by 99, 93, and 31 patients, respectively. Among the 82 patients who felt pain during at least one procedure, both CT (0.9+/-4.5) and MRI (5.2+/-16.6) were significantly less painful than Angio (24.6+/-23.4, both p<0.001). MSCT was considered significantly more comfortable (1.49+/-0.64) than MRI (1.75+/-0.81, p<0.001). In both the no-revascularization (55 patients) and the revascularization group (56 patients), the majority of the patients (73 and 71%) would prefer MSCT to MRI and Angio for future imaging of the coronary arteries. None of the patients indicated to be unwilling to undergo MSCT again. The major advantages patients attributed to MSCT were its fast, uncomplicated, noninvasive, and painless nature. CONCLUSIONS Noninvasive coronary angiography with MSCT is considered more comfortable than MRI and both MSCT and MRI are less painful than Angio. Patient preference for MSCT might tip the scales in favor of this test provided that the diagnostic accuracy of MSCT can be shown to be high enough for clinical application.
Collapse
Affiliation(s)
- Eva Schönenberger
- Department of Medicine, Medizinische Hochschule Hannover, Hannover, Germany
| | - Dirk Schnapauff
- Department of Radiology, Charité, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Florian Teige
- Department of Radiology, Charité, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Michael Laule
- Department of Cardiology, Charité, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Bernd Hamm
- Department of Radiology, Charité, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Marc Dewey
- Department of Radiology, Charité, Humboldt-Universität zu Berlin, Berlin, Germany
- * To whom correspondence should be addressed. E-mail:
| |
Collapse
|
6
|
Dewey M, Schnapauff D, Teige F, Hamm B. Non-cardiac findings on coronary computed tomography and magnetic resonance imaging. Eur Radiol 2007; 17:2038-43. [PMID: 17268800 DOI: 10.1007/s00330-006-0570-1] [Citation(s) in RCA: 76] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2006] [Revised: 11/18/2006] [Accepted: 12/21/2006] [Indexed: 01/17/2023]
Abstract
Both multislice computed tomography (CT) and magnetic resonance imaging (MRI) are emerging as methods to detect coronary artery stenoses and assess cardiac function and morphology. Non-cardiac structures are also amenable to assessment by these non-invasive tests. We investigated the rate of significant and insignificant non-cardiac findings using CT and MRI. A total of 108 consecutive patients suspected of having coronary artery disease and without contraindications to CT and MRI were included in this study. Significant non-cardiac findings were defined as findings that required additional clinical or radiological follow-up. CT and MR images were read independently in a blinded fashion. CT yielded five significant non-cardiac findings in five patients (5%). These included a pulmonary embolism, large pleural effusions, sarcoid, a large hiatal hernia, and a pulmonary nodule (>1.0 cm). Two of these significant non-cardiac findings were also seen on MRI (pleural effusions and sarcoid, 2%). Insignificant non-cardiac findings were more frequent than significant findings on both CT (n = 11, 10%) and MRI (n = 7, 6%). Incidental non-cardiac findings on CT and MRI of the coronary arteries are common, which is why images should be analyzed by radiologists to ensure that important findings are not missed and unnecessary follow-up examinations are avoided.
Collapse
Affiliation(s)
- Marc Dewey
- Department of Radiology, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Charitéplatz 1, P.O. Box 10098, 10117 Berlin, Germany.
| | | | | | | |
Collapse
|
7
|
Abstract
RATIONALE AND OBJECTIVES Reliable noninvasive detection of stenoses with multislice computed tomography (MSCT) is feasible. This study's aim was to analyze the agreement, correlation, and reliability of MSCT with conventional coronary angiography as the reference standard for quantification of coronary artery stenoses. MATERIALS AND METHODS A total of 118 significant (at least 50%) coronary artery stenoses with a reference vessel diameter of at least 1.5 mm in 62 patients were analyzed by MSCT using 16 detector rows (Aquilion, Toshiba, Otawara, Japan), multisegment reconstruction, and voxel sizes of 0.35x0.35x0.5 mm. The degree of stenosis on MSCT and quantitative coronary angiography (QCA) was measured by correlating the difference between the reference vessel diameter (average of 2 measurements directly proximal and distal to the stenosis) and the stenotic vessel diameter to the reference vessel diameter. RESULTS Correlation between the percent diameter stenosis determined by MSCT (78.2+/-13.6%) and QCA (76.0+/-14.8%) was significant (P<0.001) but only moderately so (R=0.51). Bland-Altman analysis revealed no systematic under- or overestimation with MSCT but large limits of agreements (+/-27.6%). Also the limits of agreement for interobserver agreement (reliability) of MSCT data were considerably large (+/-24.8%). Among the 27 coronary artery stenoses with a reference diameter of at least 3.5 mm, there was improved correlation (R=0.80) and the limits of agreement between MSCT and QCA were significantly smaller (+/-17.3%, P<0.008). The agreement between MSCT and QCA was not significantly different for stenoses with no calcification or only calcium spots (+/-28.2%) as compared with those with moderate-or-severe calcifications (+/-27.3%; P=0.8). MSCT allowed correct classification of coronary stenoses into low-grade (below 75%) and high-grade stenoses (at least 75%), in 62% (73 of 118). CONCLUSIONS The accuracy and reliability of coronary artery stenosis quantification with MSCT using isotropic voxel sizes and multisegment reconstruction is still too low to recommend routine clinical application because of rather low agreement, correlation, and reliability. Despite these limitations, the current results demonstrate the potential of MSCT for reliable and accurate quantification of coronary artery stenoses in the near future provided that further improvements in spatial and temporal resolution will be achieved.
Collapse
Affiliation(s)
- Marc Dewey
- Department of Radiology, Charité, Medical School, Freie Universität und Humboldt-Universität zu Berlin, Berlin, Germany.
| | | | | | | | | |
Collapse
|
8
|
Dewey M, Schönenberger E, Schnappauf D, Teige F, Laule M, Hamm B. Patientenpräferenz bei der Koronarangiographie: Vergleich von Computertomographie, Magnetresonanztomographie und konventioneller Koronarangiographie. ROFO-FORTSCHR RONTG 2007. [DOI: 10.1055/s-2007-977142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
9
|
Dewey M, Müller M, Eddicks S, Schnapauff D, Teige F, Rutsch W, Borges AC, Hamm B. Evaluation of Global and Regional Left Ventricular Function With 16-Slice Computed Tomography, Biplane Cineventriculography, and Two-Dimensional Transthoracic Echocardiography. J Am Coll Cardiol 2006; 48:2034-44. [PMID: 17112993 DOI: 10.1016/j.jacc.2006.04.104] [Citation(s) in RCA: 117] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2006] [Revised: 03/17/2006] [Accepted: 04/17/2006] [Indexed: 11/28/2022]
Abstract
OBJECTIVES We sought to compare left ventricular (LV) function assessed with multislice computed tomography (MSCT), biplane cineventriculography (CVG), and transthoracic echocardiography (Echo), with magnetic resonance imaging (MRI) as the reference standard. BACKGROUND With the same data as acquired for noninvasive coronary angiography, MSCT enables registration of myocardial function. METHODS A total of 88 patients (64 men and 24 women) underwent MSCT with 16 x 0.5 mm detector collimation, CVG, and MRI, whereas Echo was retrospectively analyzed in a subset of 30 patients. RESULTS Regarding the ejection fraction, the agreement was significantly superior for MSCT than for CVG (+/- 10.2% vs. +/- 16.8%; p < 0.001) and Echo (+/- 11.0% vs. +/- 21.2%; p < 0.001). For the end-diastolic and end-systolic volumes, the limits of agreement with CVG (p < 0.001) and Echo (p < 0.001 and p < 0.02, respectively) were also significantly larger than with MSCT. In comparison with MSCT, CVG significantly overestimated the end-diastolic and end-systolic volumes (p < 0.001). Intraobserver analysis of MSCT yielded limits of agreement for ejection fraction (+/- 4.8%), end-diastolic volume (+/- 15.6 ml) and end-systolic volume (+/- 8.0 ml), and myocardial mass (+/- 18.2 g). The accuracy in identifying patients and myocardial segments with abnormal regional function was significantly higher with MSCT (84% and 95%) than with CVG (63% and 90%; p < 0.002 and p < 0.001), whereas MSCT and Echo were not significantly different in identifying patients with abnormal regional function. CONCLUSIONS Our results indicate that the assessment of global and regional LV function with MSCT is more accurate than with CVG, whereas MSCT is superior to Echo for global function. This suggests that MSCT allows reliable evaluation of global and regional LV function.
Collapse
Affiliation(s)
- Marc Dewey
- Department of Radiology, Charité, Medical School, Humboldt-University, Berlin, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Dewey M, Teige F, Schnapauff D, Laule M, Borges AC, Rutsch W, Hamm B, Taupitz M. Combination of free-breathing and breathhold steady-state free precession magnetic resonance angiography for detection of coronary artery stenoses. J Magn Reson Imaging 2006; 23:674-81. [PMID: 16568418 DOI: 10.1002/jmri.20568] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To analyze the incremental diagnostic value of a combination of two approaches (free-breathing and breathhold) vs. the sole free-breathing approach to coronary magnetic resonance angiography (CMRA) for detection of significant stenoses. MATERIALS AND METHODS Thirty patients were consecutively included in this prospective trial. CMRA was performed on a 1.5-T MR scanner (Magnetom Sonata, Siemens) using a balanced steady-state free precession (SSFP) sequence during free-breathing (2.4 x 0.9 x 0.7 mm3). Breathholding acquisitions (3.0 x 1.5 x 0.7 mm3) were only performed in cases in which the quality of free-breathing CMRA precluded assessment. Patients with contraindications to CMRA, claustrophobia, or nonassessable images were not excluded from the assessment of diagnostic accuracy (intention-to-diagnose design). RESULTS In 60% of all free-breathing coronary acquisitions the image quality was adequate for diagnostic assessment. For the remaining 40% of the cases, breathhold acquisitions were obtained. The sensitivity, specificity, nonassessable rate, and accuracy in identifying main coronary branches with significant stenoses using the combination of both breathing approaches and the free-breathing approach alone were 65% vs. 32%, 73% vs. 53%, 24% vs. 52%, and 71% vs. 46%, respectively (P < 0.001). CONCLUSION In this consecutive cohort of patients, the combination of free-breathing and breathhold CMRA significantly improved diagnostic accuracy. Nevertheless, even this combination did not reach accuracies sufficient for routine clinical application.
Collapse
Affiliation(s)
- Marc Dewey
- Department of Radiology, Charité-Medical School, Free University and Humboldt-University, Berlin, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Dewey M, Teige F, Schnapauff D, Laule M, Borges AC, Wernecke KD, Schink T, Baumann G, Rutsch W, Rogalla P, Taupitz M, Hamm B. Noninvasive detection of coronary artery stenoses with multislice computed tomography or magnetic resonance imaging. Ann Intern Med 2006; 145:407-15. [PMID: 16983128 DOI: 10.7326/0003-4819-145-6-200609190-00004] [Citation(s) in RCA: 120] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Multislice computed tomography (CT) and magnetic resonance imaging (MRI) are the main candidates for noninvasive coronary angiography; however, multislice CT, unlike MRI, exposes patients to radiation and an iodinated intravenous contrast agent. OBJECTIVE To compare the diagnostic accuracy of multislice CT and MRI for noninvasive detection of clinically significant coronary stenoses (> or =50%). DESIGN Prospective intention-to-diagnose study. SETTING Single tertiary referral center, Berlin, Germany. PATIENTS 129 consecutive patients with suspected coronary artery disease. INTERVENTIONS Multislice CT and MRI were both performed within a median of 1 day before conventional coronary angiography, which served as the reference standard. MEASUREMENTS Diagnostic performance of multislice CT and MRI. RESULTS 129 patients completed the study. Altogether, 108 patients with 430 vessels could be examined with both multislice CT and MRI and were used for analysis. In the per-patient analysis, the sensitivity of multislice CT (92% [95% CI, 82% to 96%]) was significantly higher than that of MRI (74% [CI, 61% to 83%]; P = 0.013). The sensitivity for detecting clinically significant stenoses was 82% for multislice CT and 54% for MRI (P < 0.001). Specificity and negative predictive value of multislice CT and MRI in the per-vessel analysis were 90% versus 87% (P = 0.73) and 95% versus 90% (P = 0.032), respectively. The effective radiation dose used with multislice CT (mean, 12.3 mSv [SD, 1.4]) in a consecutive subgroup of 73 patients was not significantly different from that used with diagnostic cardiac catheterization (11.4 mSv [SD, 4.8]) (P = 0.169). Most patients (74%) indicated that they would prefer multislice CT for future diagnostic imaging (P < 0.001). LIMITATIONS This was a single-center study with 129 patients. CONCLUSIONS In patients referred for conventional coronary angiography, multislice CT compares favorably with MRI for noninvasive detection of coronary stenoses.
Collapse
Affiliation(s)
- Marc Dewey
- Department of Radiology, Charité Medical School, Humboldt-Universität, Berlin, Germany.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Dewey M, Müller M, Teige F, Schnapauff D, Schink T, Hamm B, Lembcke A. Multisegment and halfscan reconstruction of 16-slice computed tomography for assessment of regional and global left ventricular myocardial function. Invest Radiol 2006; 41:400-9. [PMID: 16523023 DOI: 10.1097/01.rli.0000201233.42994.9b] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
RATIONALE AND OBJECTIVES We sought to prospectively compare multisegment and halfscan reconstruction of 16-slice computed tomography (CT) for the assessment of regional and global left ventricular myocardial function with magnetic resonance imaging (MRI) as the reference standard. MATERIALS AND METHODS Forty-two patients underwent CT with 16 x 0.5-mm detector collimation. Electrocardiogram-gated reconstructions were generated with multisegment reconstruction (using up to 4 segments correlated with the raw data of up to 4 heartbeats) and standard halfscan reconstruction. Steady-state free-precession cine MRI was acquired within 24 hours. RESULTS More normal myocardial segments were identified correctly with multisegment (95%, 620/656) compared with halfscan reconstruction (88%, 582/656) of CT (P < 0.001). Also, the accuracy (92% [657/714] vs. 87% [620/714]) and rate of nondiagnostic segments (0% vs. 5% [33/714]) were significantly better when using multisegment reconstruction (P < 0.001). The image quality with multisegment reconstruction was significantly superior to that achieved with halfscan reconstruction (P < 0.001). In the assessment of global left ventricular function, multisegment and halfscan reconstruction of CT showed high correlations for all parameters with MRI, whereas Bland-Altman analysis revealed smaller limits of agreement for assessment of myocardial mass with multisegment reconstruction (P = 0.025), but no significant differences between both reconstruction techniques in the measurement of left ventricular volumes as compared with MRI. CONCLUSIONS Multisegment reconstruction of 16-detector row CT improves image quality and assessment of regional wall motion compared with standard halfscan reconstruction.
Collapse
Affiliation(s)
- Marc Dewey
- Department of Radiology, Freie Universität and Humboldt-Universität zu Berlin, Germany.
| | | | | | | | | | | | | |
Collapse
|
13
|
Dewey M, Müller M, Teige F, Hamm B. Evaluation of a semiautomatic software tool for left ventricular function analysis with 16-slice computed tomography. Eur Radiol 2005; 16:25-31. [PMID: 15965660 DOI: 10.1007/s00330-005-2817-7] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2005] [Revised: 05/04/2005] [Accepted: 05/09/2005] [Indexed: 12/20/2022]
Abstract
The purpose of the study was to evaluate a semiautomatic analysis tool for assessing global left ventricular myocardial function with multislice computed tomography (MSCT). We examined 33 patients with MSCT using 16x0.5 mm detector collimation and magnetic resonance imaging (MRI) on a 1.5-T scanner. MSCT data were analyzed using semiautomatic volumetric analysis software (ANET, CSCF-001A, Toshiba). This software tool automatically creates endo- and epicardial contours that can be manually corrected on all short-axis slices at all reconstructed time points within the cardiac cycle, based on a contour-detection and density-threshold algorithm. All global left ventricular function parameters assessed with the semiautomatic MSCT software were highly correlated with the results of MRI. Bland-Altman analysis showed minor systematic overestimation of end-diastolic (10.7 ml) and end-systolic volumes (5.6 ml) and underestimation of ejection fraction (2.1%) with MSCT as compared with MRI. The post-processing time was moderately but significantly longer with the MSCT software (15.9+/-2.8 min) than necessary for MRI (14.0+/-2.5 min, P<0.01), mainly as a result of the longer time required for uploading of the MSCT datasets, which were on average 54 times larger (1.3 GByte). In conclusion, it appears feasible to accurately assess global left ventricular function with MSCT in a reasonable post-processing time using a semiautomatic software tool.
Collapse
Affiliation(s)
- Marc Dewey
- Department of Radiology, Charité, Medical School, Humboldt-Universität zu Berlin, Schumannstr. 20/21, 10117, Berlin, Germany.
| | | | | | | |
Collapse
|
14
|
Dewey M, Teige F, Schnapauff D, Laule M, Rutsch W, Rogalla P, Taupitz M, Hamm B. Nichtinvasive Detektion von Koronararterienstenosen mit Mehrschicht-Computertomographie und Magnetresonanztomographie. ROFO-FORTSCHR RONTG 2005. [DOI: 10.1055/s-2005-867428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|