1
|
Altmann C, Burlacu NA, Preuss T, Hlousek A, Eddicks S. Prevalence of elevated lipoprotein(a) in cardiac rehabilitation patients - results from a large-scale multicentre registry in Germany. Clin Res Cardiol 2024:10.1007/s00392-024-02427-0. [PMID: 38619576 DOI: 10.1007/s00392-024-02427-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Accepted: 02/27/2024] [Indexed: 04/16/2024]
Abstract
BACKGROUND Lipoprotein(a) (Lp(a)) is an independent risk factor for myocardial infarction and aortic valve stenosis. European guidelines recommend assessing it at least once in a lifetime, particularly in premature atherosclerotic heart disease. METHODS A non-interventional registry was conducted at MEDIAN rehabilitation facilities in Germany to assess the frequency of Lp(a) testing in referring acute care hospitals and the prevalence of elevated Lp(a) levels in aortic valve stenosis or premature myocardial infarction. All consecutive patients referred after coronary intervention or aortic valve surgery were included in four cohorts: aortic valve intervention (cohort 1), current/previous myocardial infarction at < 60 years of age (cohorts 2a/2b), and myocardial infarction at ≥ 60 years of age (control). RESULTS The analysis included 3393 patient records (cohort 1, n = 1063; cohort 2a, n = 1351; cohort 2b, n = 381; control, n = 598). Lp(a) had been determined at the referring hospital in 0.19% (cohort 1), 4.96% (cohort 2a), 2.36% (cohort 2b), and 2.01% (control) of patients. Lp(a) levels were > 50 mg/dL or > 125 nmol/L in 28.79% (cohort 1), 29.90% (cohort 2a), and 36.48% (cohort 2b; p < 0.001) compared to 24.25% (control). Family history of premature cardiovascular disease was reported in 13.45% (cohort 1), 38.56% (cohort 2a), and 32.81% (cohort 2b) compared to 17.89% (control; p < 0.05 for each comparison). CONCLUSIONS Lp(a) had been rarely assessed in acute management of aortic valve stenosis or premature myocardial infarction despite expanding scientific evidence and guideline recommendation. Given the above-average incidence of elevated Lp(a) levels, awareness for Lp(a) has to increase substantially to better identify and manage high-risk patients.
Collapse
Affiliation(s)
- Christoph Altmann
- Department for Cardiology, MEDIAN Rehabilitation-Centre Bad Gottleuba, Königstr. 39, 01816, Bad Gottleuba-Berggießhübel, Germany.
| | - Nelu-Adrian Burlacu
- Department for Cardiology, MEDIAN Rehabilitation-Centre Bernkastel-Kues, Bernkastel-Kues, Germany
| | - Thomas Preuss
- Department for Research & Innovation, MEDIAN Headquarters, Berlin, Germany
| | - Annett Hlousek
- Department for Cardiology, MEDIAN Rehabilitation-Centre Bad Gottleuba, Königstr. 39, 01816, Bad Gottleuba-Berggießhübel, Germany
| | - Stephan Eddicks
- Department for Cardiology, MEDIAN Rehabilitation-Centre Bernkastel-Kues, Bernkastel-Kues, Germany
| |
Collapse
|
2
|
Abstract
A model of hemoperfused slaughterhouse pighearts is described providing a wide range of applications which leads to a reduction in animal experiments. The size of a pigheart, heart rate, coronary perfusion, metabolism, etc. are more comparable to conditions in patients than those in hearts of small laboratory animals. Global heart function can be assessed either by measuring stroke volume, ejection fraction, Emaxetc. in the working model or by measuring intraventricular pressure with balloon catheters in the isovolumetric model. Regional cardiac function can be measured by sonomicrometry and ischemic and non-ischemic areas can be compared. Local metabolic changes are measurable as well with microdialysis. Cardiac function can be kept on any given functional level by infusion of norepinephrine in spite of the fact that functional parameters are lower without adrenergic drive in vitro than in vivo. Stable heart function can be maintained for several hours with only 500 to 1000 ml of blood because the blood is permanently regenerated by a special dialysis system. This model can be applied in many research projects dealing with reperfusion injuries, inotropic, antiarrhythmic or arrhythmogenic effects of certain drugs, immunological rejection, evaluation of imaging systems (NMR, echocardiography etc.) or cardiac assist devices.
Collapse
Affiliation(s)
| | | | | | - I. Ast
- Mediport Biotechnik GmbH, Berlin - Germany
| | | | | |
Collapse
|
3
|
Knebel F, Eddicks S, Schimke I, Bierbaum M, Schattke S, Beling M, Raab V, Baumann G, Borges AC. Myocardial tissue Doppler echocardiography and N-terminal B-type natriuretic peptide (NT-proBNP) in diastolic and systolic heart failure. Cardiovasc Ultrasound 2008; 6:45. [PMID: 18778476 PMCID: PMC2542999 DOI: 10.1186/1476-7120-6-45] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2008] [Accepted: 09/08/2008] [Indexed: 03/12/2023] Open
Abstract
Background The aim of this prospective study was to assess the diagnostic value of NT-proBNP and the concordance with Tissue Doppler Echocardiography (including strain and longitudinal displacement) in diastolic and systolic heart failure. Methods and results 137 consecutive clinically stable patients were included (42 healthy controls, 43 with diastolic heart failure, 52 with systolic heart failure). In diastolic heart failure, basal septal strain was reduced (-24.8 ± 8.1% vs. controls. -18.5 ± 5.3%, p < 0.0001). In all patients with preserved systolic function, septal basal longitudinal displacement was impaired in patients with increased left-ventricular filling pressures (E/E' < 8: 13.5 mm ± 3.3 mm vs. E/E' > 15: 8.5 mm ± 2.3 mm, p = 0.001) parallel to NT-proBNP elevation (E/E' < 8: 45.8 pg/ml, IQR: 172.5 pg/ml vs. E/E' > 15: 402.0 pg/ml, IQR: 1337.2 pg/ml; p = 0.0007). In ROC analysis, NT-proBNP could detect patients with reduced left ventricular systolic function (LVEF ≥ 55%) with a good diagnostic accuracy. However, the diagnostic accuracy of NT-proBNP to detect diastolic dysfunction was lower. Conclusion Subtle changes of longitudinal myocardial function begin in diastolic heart failure and are further increased in systolic heart failure. In patients with preserved LV function, a complex approach with the integration of multiple parameters including Tissue Doppler echocardiography and NT-proBNP is necessary to classify patients.
Collapse
Affiliation(s)
- Fabian Knebel
- Universitätsmedizin Berlin, Medical Clinic for Cardiology and Angiology, Charité Campus Mitte, Charitéplatz 1, Berlin, Germany.
| | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Knebel F, Schattke S, Bondke H, Eddicks S, Grohmann A, Baumann G, Borges AC. Circumferential 2D-strain imaging for the prediction of long term response to cardiac resynchronization therapy. Cardiovasc Ultrasound 2008; 6:28. [PMID: 18538011 PMCID: PMC2435102 DOI: 10.1186/1476-7120-6-28] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2008] [Accepted: 06/06/2008] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Cardiac Resynchronization Therapy (CRT) leads to hemodynamic and clinical improvement in heart failure patients. The established methods to evaluate myocardial asynchrony analyze longitudinal and radial myocardial function. This study evaluates the new method of circumferential 2D-strain imaging in the prediction of the long-term response to CRT. METHODS AND RESULTS 38 heart failure patients (NYHA II-III, QRS > 120 ms, LVEF < 0.35) received CRT and echocardiographic evaluation with a mean follow-up of 9.4 months. 18 (47.4%) of the patients were hemodynamic responders to long-term CRT. In the responder group, the maximum delay in the circumferential 2D-strain in the basal segments decreased (246 +/- 94 to 123 +/- 92 ms, p < 0.001). In the non-responder group there was no significant change (pre CRT: 195 +/- 86, post CRT 135 +/- 136 ms, p = 0.84). This was paralleled by a reduction of the maximum delay in the radial and longitudinal 2D strain in the basal segments. In ROC analysis, the baseline delay of circumferential 2D strain (AUC 0.66 (+/- 0.14)) does not predict a long-term response to CRT (p = 0.37). CONCLUSION There is a significant decrease in the circumferential 2D-strain derived delays after CRT, indicating that resynchronization induces improvement in all three dimensions of myocardial contraction. However, the resulting predictive values of 2D strain delays are not superior to longitudinal and radial 2D-strain or TDI delays.
Collapse
Affiliation(s)
- Fabian Knebel
- Universitätsmedizin Berlin, Medical Clinic for Cardiology and Angiology, Charité Campus Mitte, Charitéplatz 1, 10098 Berlin, Germany.
| | | | | | | | | | | | | |
Collapse
|
5
|
Grohmann A, Elgeti T, Eddicks S, Knebel F, Rutsch W, Melzer C, Baumann G, Borges AC. Interventricular septum hematoma during cineventriculography. Cardiovasc Ultrasound 2008; 6:4. [PMID: 18199315 PMCID: PMC2257924 DOI: 10.1186/1476-7120-6-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2007] [Accepted: 01/16/2008] [Indexed: 12/20/2022] Open
Abstract
Background Intraseptal hematoma and subsequent myocardial infarction due to accidental contrast agent deposition complicating diagnostic cineventriculography is a previously undescribed complication of angiography. Case presentation A 61 year old man was admitted at intensive care unit because of unstable angina pectoris 1 hour after coronary angiography. Transthoracic contrast echocardiography showed a non-perfused area in the middle of interventricular septum with an increase of thickening up to 26 mm. Review of cineventriculography revealed contrast enhancement in the interventricular septum after contrast medium injection and a dislocation of the pigtail catheter tip. Follow up by echocardiography and MRI showed, that intramural hematoma has resolved after 6 weeks. After 8 weeks successful stent implantation in LAD was performed and after 6 month the patient had a normal LV-function without ischemic signs or septal thickening demonstrated by stressechocardiography. Conclusion A safe and mobile position of the pigtail catheter during ventriculography in the middle of the LV cavity should be ensured to avoid this potentially life-threatening complication. For assessment and absolute measurement of intramural hematoma contrast-enhanced echocardiography is more feasible than MRI and makes interchangeable results.
Collapse
Affiliation(s)
- Andrea Grohmann
- Department of Cardiology and Angiology, Charite Campus Mitte, Universitätsmedizin Berlin, Berlin, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Hartmann J, Knebel F, Eddicks S, Beling M, Grohmann A, Panda A, Jacobi CA, Müller JM, Wernecke KD, Baumann G, Borges AC. Noninvasive monitoring of myocardial function after surgical and cytostatic therapy in a peritoneal metastasis rat model: assessment with tissue Doppler and non-Doppler 2D strain echocardiography. Cardiovasc Ultrasound 2007; 5:23. [PMID: 17626632 PMCID: PMC1965460 DOI: 10.1186/1476-7120-5-23] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2007] [Accepted: 07/12/2007] [Indexed: 11/20/2022] Open
Abstract
Objective We sought to evaluate the impact of different antineoplastic treatment methods on systolic and diastolic myocardial function, and the feasibility estimation of regional deformation parameters with non-Doppler 2D echocardiography in rats. Background The optimal method for quantitative assessment of global and regional ventricular function in rats and the impact of complex oncological multimodal therapy on left- and right-ventricular function in rats remains unclear. Methods 90 rats after subperitoneal implantation of syngenetic colonic carcinoma cells underwent different onclogical treatment methods and were diveded into one control group and five treatment groups (with 15 rats in each group): group 1 = control group (without operation and without medication), group 2 = operation group without additional therapy, group 3 = combination of operation and photodynamic therapy, group 4 = operation in combination with hyperthermic intraoperative peritoneal chemotherapy with mitomycine, and group 5 = operation in combination with hyperthermic intraoperative peritoneal chemotherapy with gemcitabine, group 6 = operation in combination with taurolidin i.p. instillation. Echocardiographic examination with estimation of wall thickness, diameters, left ventricular fractional shortening, ejection fraction, early and late diastolic transmitral and myocardial velocities, radial and circumferential strain were performed 3–4 days after therapy. Results There was an increase of LVEDD and LVESD in all groups after the follow-up period (P = 0.0037). Other LV dimensions, FS and EF as well as diastolic mitral filling parameters measured by echocardiography were not significantly affected by the different treatments. Values for right ventricular dimensions and function remained unchanged, whereas circumferential 2D strain of the inferior wall was slightly, but significantly reduced under the treatment (-18.1 ± 2.5 before and -16.2 ± 2.9 % after treatment; P = 0.001) without differences between the single treatment groups. Conclusion It is feasible to assess dimensions, global function, and regional contractility with echocardiography in rats under different oncological therapy. The deformation was decreased under overall treatment without influence by one specific therapy. Therefore, deformation assessment with non-Doppler 2D strain echocardiography is more sensitive than conventional echocardiography for assessing myocardial dysfunction in rats under oncological treatment.
Collapse
Affiliation(s)
- Jens Hartmann
- Klinik für Allgemein-, Visceral-, Gefäß- und Thoraxchirurgie Charité Campus Mitte, Berlin, Germany
| | - Fabian Knebel
- Medizinische Klinik mit Schwerpunkt Kardiologie und Angiologie, Charité Campus Mitte, Berlin, Germany
| | - Stephan Eddicks
- Medizinische Klinik mit Schwerpunkt Kardiologie und Angiologie, Charité Campus Mitte, Berlin, Germany
| | - Mark Beling
- Medizinische Klinik mit Schwerpunkt Kardiologie und Angiologie, Charité Campus Mitte, Berlin, Germany
| | - Andrea Grohmann
- Medizinische Klinik mit Schwerpunkt Kardiologie und Angiologie, Charité Campus Mitte, Berlin, Germany
| | | | - Christoph A Jacobi
- Klinik für Allgemein-, Visceral-, Gefäß- und Thoraxchirurgie Charité Campus Mitte, Berlin, Germany
| | - Joachim M Müller
- Klinik für Allgemein-, Visceral-, Gefäß- und Thoraxchirurgie Charité Campus Mitte, Berlin, Germany
| | | | - Gert Baumann
- Medizinische Klinik mit Schwerpunkt Kardiologie und Angiologie, Charité Campus Mitte, Berlin, Germany
| | - Adrian C Borges
- Medizinische Klinik mit Schwerpunkt Kardiologie und Angiologie, Charité Campus Mitte, Berlin, Germany
| |
Collapse
|
7
|
Knebel F, Schattke S, Bondke H, Walde T, Eddicks S, Reibis R, Baumann G, Borges AC. Evaluation of Longitudinal and Radial Two-dimensional Strain Imaging Versus Doppler Tissue Echocardiography in Predicting Long-term Response to Cardiac Resynchronization Therapy. J Am Soc Echocardiogr 2007; 20:335-41. [DOI: 10.1016/j.echo.2006.09.007] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2006] [Indexed: 10/23/2022]
|
8
|
Mueller A, Fietze I, Voelker R, Eddicks S, Glos M, Baumann G, Theres H. Screening for sleep-related breathing disorders by transthoracic impedance recording integrated into a Holter ECG system. J Sleep Res 2007; 15:455-62. [PMID: 17118103 DOI: 10.1111/j.1365-2869.2006.00554.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
In patients with arrhythmias, coincidence with sleep-related breathing disorders (SRBD) is high and of clinical relevance. Electrocardiogram-derived (ECG) parameters have been developed for SRBD screening, but it has proved necessary to exclude patients with frequent arrhythmias. Holter-based screening tools, easy to use, are therefore warranted. The goal of our study was to evaluate the diagnostic accuracy, with respect to SRBD detection, of transthoracic impedance recording (TTIR) integrated into a Holter System. Our investigation consisted of 2 phases. In phase 1 we compared the performance of TTIR to that of in-hospital polysomnography (PSG) in 56 patients (46 male, mean age 57). In phase 2 we compared TTIR to results from an ambulatory polygraphy (PG) system in 180 patients (143 male, mean age 56). We scored apnea and hypopnea from P(S)G, and derived a respiratory-disturbance index (P(S)G-RDI). TTIR was analyzed semi-automatically. Reduction of the impedance amplitude by more than 50% over 10 s was scored as apnea/hypopnea, with consequent calculation of TTIR-RDI. In phase 1, 20 out of 56 patients revealed a PSG-RDI > 10 h(-1). TTIR-RDI in 19 patients from this group was >10 h(-1) (sensitivity 95%, specificity 97.2%, positive predictive value 95%, negative predictive value 97.2%, interclass correlation coefficient 0.98). In phase 2, 46 of 180 patients revealed a PSG-RDI > 10 h(-1). TTIR-RDI in 37 out of this group was >10 h(-1) (sensitivity 80.4%, specificity 92.5%, positive predictive value 78.7%, negative predictive value 93.2%, interclass correlation coefficient 0.92). TTIR integrated into a Holter ECG system and tested in a large patient cohort demonstrates acceptable high accuracy in detection of SRBD. Arrhythmia analysis and screening for SRBD can be performed in a single-step approch.
Collapse
Affiliation(s)
- Andreas Mueller
- Charité University Medical Centre, Medical Division, Department for Cardiology and Angiology, Berlin, Germany.
| | | | | | | | | | | | | |
Collapse
|
9
|
Eddicks S, Maier-Hauff K, Schenk M, Müller A, Baumann G, Theres H. Thoracic spinal cord stimulation improves functional status and relieves symptoms in patients with refractory angina pectoris: the first placebo-controlled randomised study. Heart 2007; 93:585-90. [PMID: 17237126 PMCID: PMC1955532 DOI: 10.1136/hrt.2006.100784] [Citation(s) in RCA: 100] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
BACKGROUND Spinal cord stimulation (SCS) is an alternative treatment option for refractory angina. Controlled trials demonstrate symptom relief and improvement in functional status. Since patients experience retrosternal prickling during active SCS, there is no option for blinding patients to active treatment or for placebo control. OBJECTIVE To examine the therapeutic effects of subthreshold SCS in patients with refractory angina in a placebo-controlled study. METHODS 12 responders to treatment who had already been treated with SCS for refractory angina were enrolled. Patients were randomised into four consecutive treatment arms, each for 4 weeks, with various stimulation timing and output parameters: 3 x 2 h/day (phase A) and 24 h/day with conventional output (phase B); 3 x 2 h/day with a subthreshold output (phase C); and 24 h/day with 0.1 V output, which served as control (phase D). Functional status, quality of life, Canadian Cardiovascular Society classification and nitrate usage were assessed at the end of each 4-week period. RESULTS In phase D, patients showed a significant reduction in walking distance compared with phases A and C. Canadian Cardiovascular Society classification worsened in phase D compared with phases A-C. Frequency of angina attacks and the visual analogue scale were significantly worse in phase D than in phases A-C. In three patients, it was necessary to prematurely terminate phase D owing to intolerable angina attacks. CONCLUSIONS In this first placebo-controlled trial to apply SCS in patients with refractory angina, improvement in functional status and symptoms was revealed in phases with conventional or subthreshold stimulation, in comparison to a low-output (placebo) phase.
Collapse
Affiliation(s)
- Stephan Eddicks
- Charité-Universitätsmedizin Berlin, Campus Charité Mitte, Medizinische Klinik mit Schwerpunkt Kardiologie, Angiologie und Pulmologie, Berlin, Germany
| | | | | | | | | | | |
Collapse
|
10
|
Melzer C, Lembcke A, Ziemer S, Eddicks S, Witte J, Baumann G, Borges AC. Pacemaker-Induced Superior Vena Cava Syndrome: Clinical Evaluation of Long-Term Follow-Up. Pacing Clin Electro 2006; 29:1346-51. [PMID: 17201841 DOI: 10.1111/j.1540-8159.2006.00546.x] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Pacemaker-induced superior vena cava (SVC) syndrome is a rare but serious complication of permanent pacemaker implantation. Because of its rarity, little is known about the long-term prognoses of such patients. METHODS Five patients, mean age 62 +/- 11.4 years, with pacemaker-induced SVC syndrome for more than 10 years were investigated. The clinical evaluation included: exercise testing, thrombophilia lab tests, and a chest CT. RESULTS Two of the patients manifested complications of SVC syndrome which included thoracoabdominal subcutaneous collaterals. One of these patients simultaneously developed an increase in the pacing threshold which required the implantation of epicardial leads. Three of the five patients had normal age-adjusted VO(2) AT und VO(2) max. Four of the patients were both heterozygous for a polymorphism of PAI-1 and were homozygous for a polymorphism of t-PA. One of these patients also was heterozygous for a polymorphism of factor V and glycoprotein IIb/IIIa. The chest CTs revealed extensive and varying collateral circulation patterns in all of the patients. CONCLUSIONS The development of pacemaker-induced SVC syndrome is the result of various predisposing factors including thrombophilia. Many patients retain normal age-adjusted cardiopulmonary capacity and demonstrate stable clinical findings on the long-term as the result of the development of extensive collateral vessel systems. The most serious complication was the combination of SVC syndrome and the simultaneous malfunctioning of one of the leads requiring implantation of a new lead.
Collapse
Affiliation(s)
- Christoph Melzer
- Department of Internal Medicine, Clinic for Cardiology and Angiology, Charité University Medical Center, Berlin, Germany.
| | | | | | | | | | | | | |
Collapse
|
11
|
Dewey M, Müller M, Eddicks S, Schnapauff D, Teige F, Rutsch W, Borges AC, Hamm B. Evaluation of Global and Regional Left Ventricular Function With 16-Slice Computed Tomography, Biplane Cineventriculography, and Two-Dimensional Transthoracic Echocardiography. J Am Coll Cardiol 2006; 48:2034-44. [PMID: 17112993 DOI: 10.1016/j.jacc.2006.04.104] [Citation(s) in RCA: 117] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2006] [Revised: 03/17/2006] [Accepted: 04/17/2006] [Indexed: 11/28/2022]
Abstract
OBJECTIVES We sought to compare left ventricular (LV) function assessed with multislice computed tomography (MSCT), biplane cineventriculography (CVG), and transthoracic echocardiography (Echo), with magnetic resonance imaging (MRI) as the reference standard. BACKGROUND With the same data as acquired for noninvasive coronary angiography, MSCT enables registration of myocardial function. METHODS A total of 88 patients (64 men and 24 women) underwent MSCT with 16 x 0.5 mm detector collimation, CVG, and MRI, whereas Echo was retrospectively analyzed in a subset of 30 patients. RESULTS Regarding the ejection fraction, the agreement was significantly superior for MSCT than for CVG (+/- 10.2% vs. +/- 16.8%; p < 0.001) and Echo (+/- 11.0% vs. +/- 21.2%; p < 0.001). For the end-diastolic and end-systolic volumes, the limits of agreement with CVG (p < 0.001) and Echo (p < 0.001 and p < 0.02, respectively) were also significantly larger than with MSCT. In comparison with MSCT, CVG significantly overestimated the end-diastolic and end-systolic volumes (p < 0.001). Intraobserver analysis of MSCT yielded limits of agreement for ejection fraction (+/- 4.8%), end-diastolic volume (+/- 15.6 ml) and end-systolic volume (+/- 8.0 ml), and myocardial mass (+/- 18.2 g). The accuracy in identifying patients and myocardial segments with abnormal regional function was significantly higher with MSCT (84% and 95%) than with CVG (63% and 90%; p < 0.002 and p < 0.001), whereas MSCT and Echo were not significantly different in identifying patients with abnormal regional function. CONCLUSIONS Our results indicate that the assessment of global and regional LV function with MSCT is more accurate than with CVG, whereas MSCT is superior to Echo for global function. This suggests that MSCT allows reliable evaluation of global and regional LV function.
Collapse
Affiliation(s)
- Marc Dewey
- Department of Radiology, Charité, Medical School, Humboldt-University, Berlin, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Eddicks S, Kivelitz D, Breitwieser C, Knebel F, Theres H, Baumann G, Borges AC. Right ventricular metastasis caused by a renal cell carcinoma (Grawitz tumor): case report. J Am Soc Echocardiogr 2006; 19:1073.e11-5. [PMID: 16880109 DOI: 10.1016/j.echo.2006.04.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2006] [Indexed: 11/24/2022]
Affiliation(s)
- Stephan Eddicks
- Department of Cardiology, Angiology, and Pneumology, Charité Campus Mitte, Universitätsmedizin Berlin, Berlin, Germany.
| | | | | | | | | | | | | |
Collapse
|
13
|
Borges AC, Knebel F, Eddicks S, Panda A, Schattke S, Witt C, Baumann G. Right ventricular function assessed by two-dimensional strain and tissue Doppler echocardiography in patients with pulmonary arterial hypertension and effect of vasodilator therapy. Am J Cardiol 2006; 98:530-4. [PMID: 16893711 DOI: 10.1016/j.amjcard.2006.02.060] [Citation(s) in RCA: 105] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2005] [Revised: 02/16/2006] [Accepted: 02/16/2006] [Indexed: 11/26/2022]
Abstract
Two-dimensional strain echocardiography is a new method for the assessment of regional contractility. Thirty-seven patients with pulmonary arterial hypertension (mean age 56.4 +/- 11 years) and 38 normal subjects (mean age 58.3 +/- 12 years) underwent 2-dimensional echocardiography and tissue Doppler echocardiographic evaluation of right ventricular (RV) global function and regional contractility. Patients with pulmonary arterial hypertension additionally underwent 6-minute walking distance tests and right-sided cardiac catheterization before and after (8 +/- 3 months) vasodilator therapy. Moderate or severe RV dysfunction was present in all patients (2-dimensional strain of the basal segment of the RV free wall: -8.8 +/- 4.1% systolic longitudinal deformation) compared with normal subjects (-24.3 +/- 4.7% systolic longitudinal deformation, p < 0.001) and was improved with vasodilator therapy after 6 to 11 months (-13.3 +/- 6.2% systolic longitudinal deformation, p < 0.001).
Collapse
|
14
|
Thomas KH, Probst M, Kruell M, Krug L, Eddicks S, Suttorp N, Rosseau S. Paratial anomalous pulmonary venous connection in a patient with cardiac failure and sepsis. Intensive Care Med 2006; 32:948-9. [PMID: 16572326 DOI: 10.1007/s00134-006-0168-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/16/2006] [Indexed: 11/24/2022]
|
15
|
Borges AC, Knebel F, Eddicks S, Bondke HJ, Baumann G. [Echocardiographic evaluation to select patients for cardiac resynchronization therapy]. Herzschrittmacherther Elektrophysiol 2006; 17 Suppl 1:I63-72. [PMID: 16598624 DOI: 10.1007/s00399-006-1110-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Wide QRS complex and asynchronous myocardial contraction in heart failure are associated with poor prognosis. Resynchronization can be achieved by biventricular pacing (BVP), which leads to hemodynamic and clinical improvement and reverse remodeling, and may improve survival. However, there is a substantial subset of patients with wide QRS complexes in the electrocardiogram who does not improve despite BVP, and there are findings which suggest that resynchronization therapy may be also beneficial for heart failure patients with normal QRS duration. QRS width predicts the benefit of BVP only with limitation and only correlates weakly with echocardiographically determined myocardial asynchrony. Determination of asynchrony by tissue Doppler echocardiography seems to be the best predictor for improvement after BVP, although no consensus on the optimal method to assess asynchrony has yet been achieved. To date, most studies evaluating tissue Doppler echo in BVP were performed retrospectively and only one prospective study with patient selection for BVP according to echocardiography and electrocardiography criteria of asynchrony has been published. These new echocardiographic tools will help to prospectively select patients for BVP, help to guide implantation and to optimize device programming.
Collapse
Affiliation(s)
- A C Borges
- Medizinische Klinik der Charité, Charité Campus Mitte-Universitätsmedizin Berlin, Schumannstr. 20-21, 10117 Berlin.
| | | | | | | | | |
Collapse
|
16
|
|
17
|
Jochmann N, Kiecker F, Borges AC, Hofmann MA, Eddicks S, Sterry W, Baumann G, Trefzer U. Long-term therapy of interferon-alpha induced pulmonary arterial hypertension with different PDE-5 inhibitors: a case report. Cardiovasc Ultrasound 2005; 3:26. [PMID: 16138923 PMCID: PMC1208925 DOI: 10.1186/1476-7120-3-26] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2005] [Accepted: 09/02/2005] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Interferon alpha2 is widely used in hepatitis and high-risk melanoma. Interferon-induced pulmonary arterial hypertension as a side effect is rare. CASE PRESENTATION We describe a melanoma patient who developed severe pulmonary arterial hypertension 30 months after initiation of adjuvant interferon alpha2b therapy. Discontinuation of interferon did not improve pulmonary arterial hypertension. This patient could be treated successfully with phosphodiesterase-5 inhibitor therapy. CONCLUSION This is only the 5th case of interferon-induced pulmonary arterial hypertension and the first documented case where pulmonary arterial hypertension was not reversible after termination of interferon alpha2 therapy. If interferon alpha2 treated patients develop respiratory symptoms, pulmonary arterial hypertension should be considered in the differential diagnosis. For these patients phosphodiesterase-5 inhibitors, e.g. sildenafil or vardenafil, could be an effective therapeutic approach.
Collapse
Affiliation(s)
- Nicoline Jochmann
- Department of Cardiology, Charité – Universitätsmedizin Berlin, Campus Mitte, Berlin, Germany, Schumannstrasse 20/21, 10117 Berlin, Germany
| | - Felix Kiecker
- Department of Dermatology and Allergy, Skin Cancer Centre, Charité – Universitätsmedizin Berlin, Schumannstrasse 20/21, 10117 Berlin, Germany
| | - Adrian C Borges
- Department of Cardiology, Charité – Universitätsmedizin Berlin, Campus Mitte, Berlin, Germany, Schumannstrasse 20/21, 10117 Berlin, Germany
| | - Maja A Hofmann
- Department of Dermatology and Allergy, Skin Cancer Centre, Charité – Universitätsmedizin Berlin, Schumannstrasse 20/21, 10117 Berlin, Germany
| | - Stephan Eddicks
- Department of Cardiology, Charité – Universitätsmedizin Berlin, Campus Mitte, Berlin, Germany, Schumannstrasse 20/21, 10117 Berlin, Germany
| | - Wolfram Sterry
- Department of Dermatology and Allergy, Skin Cancer Centre, Charité – Universitätsmedizin Berlin, Schumannstrasse 20/21, 10117 Berlin, Germany
| | - Gert Baumann
- Department of Cardiology, Charité – Universitätsmedizin Berlin, Campus Mitte, Berlin, Germany, Schumannstrasse 20/21, 10117 Berlin, Germany
| | - Uwe Trefzer
- Department of Dermatology and Allergy, Skin Cancer Centre, Charité – Universitätsmedizin Berlin, Schumannstrasse 20/21, 10117 Berlin, Germany
| |
Collapse
|
18
|
Knebel F, Schimke I, Eddicks S, Walde T, Ziebig R, Schattke S, Baumann G, Borges AC. Does contrast echocardiography induce increases in markers of myocardial necrosis, inflammation and oxidative stress suggesting myocardial injury? Cardiovasc Ultrasound 2005; 3:21. [PMID: 16107209 PMCID: PMC1208924 DOI: 10.1186/1476-7120-3-21] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2005] [Accepted: 08/17/2005] [Indexed: 11/29/2022] Open
Abstract
Background Contrast echocardiography is a precise tool for the non-invasive assessment of myocardial function and perfusion. Side effects of contrast echocardiography resulting from contrast-agent induced myocardial micro-lesions have been found in animals. The goal of this study is to measure markers of myocardial necrosis, inflammation and oxidative stress in humans to evaluate potential side-effects of contrast echocardiography. Methods 20 patients who underwent contrast echocardiography with Optison as the contrast medium were investigated. To evaluate myocardial micro-necrosis, inflammation and oxidative stress, cardiac troponin I (cTnI), tumor necrosis factor-α (TNF-α), interleukin (IL)-6, -8 and thiobarbituric acid reactive substances (TBARS) were measured at baseline and at 2, 4, 8 and 24 hours after contrast echocardiography. Results At baseline, 50% of the patients had cTnI and TBARS values outside the reference range. TNF-α, IL-6, IL-8 levels were within the reference range. Patients with cTnI above the RR clustered to significantly higher levels of TNF-α and IL-6. After contrast echocardiography, no statistically significant increase of cTnI, cytokines and TBARS was found. However, for nearly 50% of the patients, the intra-individual cTnI kinetics crossed the critical difference (threefold of methodical variation) which indicates a marker increase. This was neither predicted by the baseline levels of the cytokines nor the markers of oxidative stress. Conclusion There are no clinically relevant increases in serum markers for micro-necrosis, inflammation and oxidative stress in humans after contrast echocardiography. Future studies have to address whether cTnI increase in some patients represent a subset with increased risk for side effects after contrast echocardiography.
Collapse
Affiliation(s)
- Fabian Knebel
- Universitätsmedizin Berlin, Medical Clinic for Cardiology, Angiology, Pulmology, Charité Campus Mitte, Germany
| | - Ingolf Schimke
- Universitätsmedizin Berlin, Medical Clinic for Cardiology, Angiology, Pulmology, Charité Campus Mitte, Germany
| | - Stephan Eddicks
- Universitätsmedizin Berlin, Medical Clinic for Cardiology, Angiology, Pulmology, Charité Campus Mitte, Germany
| | - Torsten Walde
- Paritätisches Krankenhaus Lichtenberg, Fanningerstraße 32, 10365 Berlin, Lichtenberg, Germany
| | - Reinhard Ziebig
- Universitätsmedizin Berlin, Institute for Laboratory Medicine and Pathobiochemistry, Charité Campus Mitte, Germany
| | - Sebastian Schattke
- Universitätsmedizin Berlin, Medical Clinic for Cardiology, Angiology, Pulmology, Charité Campus Mitte, Germany
| | - Gert Baumann
- Universitätsmedizin Berlin, Medical Clinic for Cardiology, Angiology, Pulmology, Charité Campus Mitte, Germany
| | - Adrian Constantin Borges
- Universitätsmedizin Berlin, Medical Clinic for Cardiology, Angiology, Pulmology, Charité Campus Mitte, Germany
| |
Collapse
|
19
|
Knebel F, Gliech V, Walde T, Eddicks S, Konertz W, Baumann G, Borges AC. High concordance of invasive and echocardiographic mean pressure gradients in patients with a mechanical aortic valve prosthesis. J Heart Valve Dis 2005; 14:332-7. [PMID: 15974527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
BACKGROUND AND AIM OF THE STUDY Conflicting data exist regarding the accuracy of echocardiographic Doppler gradients compared to invasive pressure gradients in the hemodynamic assessment of patients with prosthetic aortic valves. The study aim was to determine the correlation between these measurements for mechanical single- and double-leaflet aortic valve prostheses in vivo. METHODS Forty-four patients with an aortic valve prosthesis were included in this prospective study. Transthoracic echocardiography was performed immediately before the invasive measurements. Left ventricular pressure measurements were achieved by either atrial transseptal puncture and antegrade, transmitral left ventricular catheterization or--in the case of mitral valve replacement--direct left ventricular puncture. RESULTS Comparison of echocardiographic and invasive mean pressure gradients of all examined aortic prosthetic valves revealed a Pearson correlation r = 0.59 (p < 0.001). The mean pressure gradient was overestimated by 7.4 mmHg with echocardiography. Classifying patients into clinically relevant categories (mild, moderate, severely increased pressure gradient) resulted in a kappa value of 0.72 and an agreement of 86.4%. There was no relevant difference between single- and double-leaflet valves. CONCLUSION A high concordance was found between echocardiographic and invasive mean pressure gradients in vivo. Invasive measurements of the prosthetic valve gradients therefore seem to be indicated only in patients with contradictory echocardiographic and clinical findings.
Collapse
Affiliation(s)
- Fabian Knebel
- Charité University Medicine Berlin, Campus Mitte, Department of Cardiology, Berlin, Germany.
| | | | | | | | | | | | | |
Collapse
|
20
|
Knebel F, Reibis RK, Bondke HJ, Witte J, Walde T, Eddicks S, Baumann G, Borges AC. Tissue Doppler echocardiography and biventricular pacing in heart failure: patient selection, procedural guidance, follow-up, quantification of success. Cardiovasc Ultrasound 2004; 2:17. [PMID: 15369591 PMCID: PMC521694 DOI: 10.1186/1476-7120-2-17] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2004] [Accepted: 09/15/2004] [Indexed: 01/26/2023] Open
Abstract
Asynchronous myocardial contraction in heart failure is associated with poor prognosis. Resynchronization can be achieved by biventricular pacing (BVP), which leads to clinical improvement and reverse remodeling. However, there is a substantial subset of patients with wide QRS complexes in the electrocardiogram that does not improve despite BVP. QRS width does not predict benefit of BVP and only correlates weakly with echocardiographically determined myocardial asynchrony. Determination of asynchrony by Tissue Doppler echocardiography seems to be the best predictor for improvement after BVP, although no consensus on the optimal method to assess asynchrony has been achieved yet. Our own preliminary results show the usefulness of Tissue Doppler Imaging and Tissue Synchronization Imaging to document acute and sustained improvement after BVP. To date, all studies evaluating Tissue Doppler in BVP were performed retrospectively and no prospective studies with patient selection for BVP according to echocardiographic criteria of asynchrony were published yet. We believe that these new echocardiographic tools will help to prospectively select patients for BVP, help to guide implantation and to optimize device programming.
Collapse
Affiliation(s)
- Fabian Knebel
- Charité Campus Mitte – University Medicine Berlin, Medical Clinic for Cardiology, Angiology, Pneumology, 10098 Berlin, Germany
| | - Rona Katharina Reibis
- Klinik am See, Department of Cardiology, Rehabilitation Center of Cardiovascular Diseases, Seebad 84, 15562 Rüdersdorf (Berlin), Germany
| | - Hans-Jürgen Bondke
- Charité Campus Mitte – University Medicine Berlin, Medical Clinic for Cardiology, Angiology, Pneumology, 10098 Berlin, Germany
| | - Joachim Witte
- Charité Campus Mitte – University Medicine Berlin, Medical Clinic for Cardiology, Angiology, Pneumology, 10098 Berlin, Germany
| | - Torsten Walde
- Charité Campus Mitte – University Medicine Berlin, Medical Clinic for Cardiology, Angiology, Pneumology, 10098 Berlin, Germany
| | - Stephan Eddicks
- Charité Campus Mitte – University Medicine Berlin, Medical Clinic for Cardiology, Angiology, Pneumology, 10098 Berlin, Germany
| | - Gert Baumann
- Charité Campus Mitte – University Medicine Berlin, Medical Clinic for Cardiology, Angiology, Pneumology, 10098 Berlin, Germany
| | - Adrian Constantin Borges
- Charité Campus Mitte – University Medicine Berlin, Medical Clinic for Cardiology, Angiology, Pneumology, 10098 Berlin, Germany
| |
Collapse
|
21
|
Knebel F, Gliech V, Walde T, Panda A, Sanad W, Eddicks S, Baumann G, Borges AC. Percutaneous closure of interatrial communications in adults - prospective embolism prevention study with two- and three-dimensional echocardiography. Cardiovasc Ultrasound 2004; 2:5. [PMID: 15151699 PMCID: PMC441405 DOI: 10.1186/1476-7120-2-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2004] [Accepted: 05/19/2004] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Patients with interatrial communications after paradoxical embolic events are at risk for recurrent thromboembolism. We hypothesized that transcatheter closure of the defects would result in long-term prevention of systemic embolism and performed clinical and echocardiographic follow-up. METHODS We included 161 patients (mean age 46.8 +/- 11 years, 83 females) with patent foramen ovale or atrial septal defect and at least one documented paradoxical systemic thrombembolic event and/or a large atrial shunting. RESULTS The implantation procedure was successfully performed without major complications in all patients and minor complications in 2.5%. Two and / or three dimensional echocardiography was performed before and after 4 weeks and 12 months using a multiplane transoesophageal probe. After 4 weeks and 6 months two patients had minimal shunting. These residual defects were closed with a second device implantation without shunting after further 4 weeks. During a follow-up of 324.3 patient years (range, 13 to 19 months), recurrent embolic events occurred in only 1 patient (0.6%). CONCLUSION After primary paradoxical systemic embolism, results of transcatheter occlusion of the interatrial communications are dependent on the closure device system and can prevent further secondary embolic events for up to 1 year after the percutaneous closure. Three dimensional echocardiography provides dynamic features of the defects and the post closure status and may lead to an improved understanding and diagnosis of the interatrial defect.
Collapse
Affiliation(s)
- Fabian Knebel
- Medical Clinic for Cardiology, Angiology, Pulmology, Charité Campus Mitte, Berlin, Germany
| | - Volker Gliech
- Medical Clinic for Cardiology, Angiology, Pulmology, Charité Campus Mitte, Berlin, Germany
| | - Torsten Walde
- Medical Clinic for Cardiology, Angiology, Pulmology, Charité Campus Mitte, Berlin, Germany
| | - Alexander Panda
- Medical Clinic for Cardiology, Angiology, Pulmology, Charité Campus Mitte, Berlin, Germany
| | - Wasiem Sanad
- Medical Clinic for Cardiology, Angiology, Pulmology, Charité Campus Mitte, Berlin, Germany
| | - Stephan Eddicks
- Medical Clinic for Cardiology, Angiology, Pulmology, Charité Campus Mitte, Berlin, Germany
| | - Gert Baumann
- Medical Clinic for Cardiology, Angiology, Pulmology, Charité Campus Mitte, Berlin, Germany
| | - Adrian C Borges
- Medical Clinic for Cardiology, Angiology, Pulmology, Charité Campus Mitte, Berlin, Germany
| |
Collapse
|
22
|
Modersohn D, Eddicks S, Ast I, Holinski S, Konertz W. Influence of transmyocardial laser revascularization (TMLR) on regional cardiac function and metabolism in an isolated hemoperfused working pig heart. Int J Artif Organs 2002; 25:1074-81. [PMID: 12487395 DOI: 10.1177/039139880202501106] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The mechanism of an indirect revascularization in ischemic myocardium by transmyocardial laser revascularization (TMLR) is not yet fully understood. An improvement of clinical symptoms caused by TMLR is reported in many clinical trials with patients in which a direct revascularization is not possible. An increase of myocardial perfusion through laser channels is doubtful, because the myocardial pressure in the wall is higher than in the cavum. Therefore we measured the local cardiac function (intramyocardial pressure, wall thickness, pressure-length curves) and acute metabolic changes (tissue lactate content, tissue pO2) in ischemic and nonischemic regions before and after TMLR in isolated hemoperfused pig hearts. An isolated heart was chosen because it enabled us to separate coronary flow from flow through ventricular channels. The ischemia was induced by coronary occlusion or microembolization (eight hearts each). It should be noted that microembolization leads to conditions which are more comparable with those found in patients selected for TMLR. In the isolated working heart, the coronary perfusion can be controlled independently from perfusion through the ventricular cavum. Under the ischemic conditions mentioned above, we observed that the intramyocardial pressure in the ischemic region decreased below the left ventricular pressure, so one premise for indirect perfusion was met. TMLR after microembolization led to a significant improvement of regional cardiac work and the tissue oxygen pressure. These acute effects demonstrate the possibility of functional and metabolic amelioration by TMLR after ischemia induced by microembolization in an isolated hemoperfused pig heart.
Collapse
Affiliation(s)
- D Modersohn
- Clinic for Cardiovascular Surgery, Charité, Humboldt-University, Berlin, Germany.
| | | | | | | | | |
Collapse
|
23
|
Modersohn D, Eddicks S, Grosse-Siestrup C, Ast I, Holinski S, Konertz W. Isolated hemoperfused heart model of slaughterhouse pigs. Int J Artif Organs 2001; 24:215-21. [PMID: 11394703] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/20/2023]
Abstract
A model of hemoperfused slaughterhouse pighearts is described providing a wide range of applications which leads to a reduction in animal experiments. The size of a pigheart, heart rate, coronary perfusion, metabolism, etc. are more comparable to conditions in patients than those in hearts of small laboratory animals. Global heart function can be assessed either by measuring stroke volume, ejection fraction, Emax etc. in the working model or by measuring intraventricular pressure with balloon catheters in the isovolumetric model. Regional cardiac function can be measured by sonomicrometry and ischemic and non-ischemic areas can be compared. Local metabolic changes are measurable as well with microdialysis. Cardiac function can be kept on any given functional level by infusion of norepinephrine in spite of the fact that functional parameters are lower without adrenergic drive in vitro than in vivo. Stable heart function can be maintained for several hours with only 500 to 1000 ml of blood because the blood is permanently regenerated by a special dialysis system. This model can be applied in many research projects dealing with reperfusion injuries, inotropic, antiarrhythmic or arrhythmogenic effects of certain drugs, immunological rejection, evaluation of imaging systems (NMR, echocardiography etc.) or cardiac assist devices.
Collapse
Affiliation(s)
- D Modersohn
- Klinik für Kardiovaskuläre Chirurgie, Charité, Humboldt-Univerisät Berlin, Germany.
| | | | | | | | | | | |
Collapse
|