51
|
Lin Y, Zhu N, Yu P, Su L, Mao L. Physiologically relevant online electrochemical method for continuous and simultaneous monitoring of striatum glucose and lactate following global cerebral ischemia/reperfusion. Anal Chem 2010; 81:2067-74. [PMID: 19281258 DOI: 10.1021/ac801946s] [Citation(s) in RCA: 101] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
This study demonstrates a new electroanalytical method with a high physiological relevance for simultaneous online monitoring of glucose and lactate in the striatum of the rat brain following global cerebral ischemia/reperfusion. The online analytical method is based on the efficient integration of in vivo microdialysis sampling with an online selective electrochemical detection with the electrochemical biosensors with dehydrogenases, i.e., glucose and lactate dehydrogenases, as recognition elements. The dehydrogenase-based electrochemical biosensors are developed onto the dual split-disk plastic carbon film (SPCF) electrodes with methylene green (MG) adsorbed onto single-walled carbon nanotubes (SWNTs) as the electrocatalyst for the oxidation of dihydronicotiamide adenine dinucleotide (NADH) at a low potential of 0.0 V (vs Ag/AgCl). Artificial cerebrospinal fluid (aCSF) containing NAD(+) is externally perfused from a second pump and online mixed with the brain microdialysates to minimize the variation of pH that occurred following the cerebral ischemia/reperfusion and to supply NAD(+) cofactor and O(2) for the enzymatic reactions of dehydrogenases and ascorbate oxidase, respectively. As a result, the developed online electroanalytical method exhibits a high selectivity against the electrochemically active species endogenously existing in the cerebral systems and a high tolerance against the variation of pH and O(2) following cerebral ischemia/reperfusion. This property, along with the good linearity and a high stability toward glucose and lactate as well as little cross-talk between two biosensors, substantially makes this method possible for the continuous, simultaneous, and online monitoring of glucose and lactate in the rat brain following global cerebral ischemia/reperfusion. This study establishes a new and effective platform for the investigation of the energy metabolism in physiological and pathological processes.
Collapse
Affiliation(s)
- Yuqing Lin
- Beijing National Laboratory for Molecular Sciences, Institute of Chemistry, The Chinese Academy of Sciences, Beijing 100190, China
| | | | | | | | | |
Collapse
|
52
|
Zeiger SLH, McKenzie JR, Stankowski JN, Martin JA, Cliffel DE, McLaughlin B. Neuron specific metabolic adaptations following multi-day exposures to oxygen glucose deprivation. Biochim Biophys Acta Mol Basis Dis 2010; 1802:1095-104. [PMID: 20656023 DOI: 10.1016/j.bbadis.2010.07.013] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2010] [Revised: 07/13/2010] [Accepted: 07/19/2010] [Indexed: 12/22/2022]
Abstract
Prior exposure to sub toxic insults can induce a powerful endogenous neuroprotective program known as ischemic preconditioning. Current models typically rely on a single stress episode to induce neuroprotection whereas the clinical reality is that patients may experience multiple transient ischemic attacks (TIAs) prior to suffering a stroke. We sought to develop a neuron-enriched preconditioning model using multiple oxygen glucose deprivation (OGD) episodes to assess the endogenous protective mechanisms neurons implement at the metabolic and cellular level. We found that neurons exposed to a five minute period of glucose deprivation recovered oxygen utilization and lactate production using novel microphysiometry techniques. Using the non-toxic and energetically favorable five minute exposure, we developed a preconditioning paradigm where neurons are exposed to this brief OGD for three consecutive days. These cells experienced a 45% greater survival following an otherwise lethal event and exhibited a longer lasting window of protection in comparison to our previous in vitro preconditioning model using a single stress. As in other models, preconditioned cells exhibited mild caspase activation, an increase in oxidized proteins and a requirement for reactive oxygen species for neuroprotection. Heat shock protein 70 was upregulated during preconditioning, yet the majority of this protein was released extracellularly. We believe coupling this neuron-enriched multi-day model with microphysiometry will allow us to assess neuronal specific real-time metabolic adaptations necessary for preconditioning.
Collapse
|
53
|
Ges IA, Baudenbacher F. Enzyme-coated microelectrodes to monitor lactate production in a nanoliter microfluidic cell culture device. Biosens Bioelectron 2010; 26:828-33. [PMID: 20566279 DOI: 10.1016/j.bios.2010.05.030] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2010] [Revised: 05/07/2010] [Accepted: 05/24/2010] [Indexed: 01/09/2023]
Abstract
Monitoring the degree of anaerobic respiration of cells in high density microscale culture systems is an enabling key technology and essential for cell-based biosensors. We have fabricated and incorporated miniature amperometric lactate sensing electrodes with working areas from 3 to 5×10(-2) mm2 into a microfluidic-based microscale cell culture system to measure the lactate production rate of fibroblasts in nanoliter volumes. Planar thin film platinum electrode arrays on glass substrates were spin coated with lactate oxidase and a protective Nafion layer. The lactate electrodes had a high enzymatic activity described by a Michaelis-Menten constant of 2.6±0.1 mM, a linear response in the range 0.01-2.5 mM and a sensitivity of 7.3×10(-2) mA/mM cm2. A replica-molded polydimethylsiloxane (PDMS) microfluidic device with nanoliter sensing volumes was aligned and sealed to a glass substrate with the sensing electrodes. We trapped fibroblasts in the cell culture volume and measured the lactate production rate using a stop-flow protocol. The average lactate production rate was 0.011±0.0049 mM/min. The lactate production was suppressed with the addition of 2-deoxy-D-glucose, which binds to hexokinase. The blocking of hexokinase prevents the generation of pyruvate, the intermittent substrate required for lactate production even in the presence of glucose.
Collapse
Affiliation(s)
- Igor A Ges
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, VU Station B 351631, Nashville, TN 37235-1631, USA
| | | |
Collapse
|
54
|
The effects of cholera toxin on cellular energy metabolism. Toxins (Basel) 2010; 2:632-48. [PMID: 22069603 PMCID: PMC3153216 DOI: 10.3390/toxins2040632] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2010] [Revised: 03/31/2010] [Accepted: 04/06/2010] [Indexed: 11/27/2022] Open
Abstract
Multianalyte microphysiometry, a real-time instrument for simultaneous measurement of metabolic analytes in a microfluidic environment, was used to explore the effects of cholera toxin (CTx). Upon exposure of CTx to PC-12 cells, anaerobic respiration was triggered, measured as increases in acid and lactate production and a decrease in the oxygen uptake. We believe the responses observed are due to a CTx-induced activation of adenylate cyclase, increasing cAMP production and resulting in a switch to anaerobic respiration. Inhibitors (H-89, brefeldin A) and stimulators (forskolin) of cAMP were employed to modulate the CTx-induced cAMP responses. The results of this study show the utility of multianalyte microphysiometry to quantitatively determine the dynamic metabolic effects of toxins and affected pathways.
Collapse
|
55
|
Evaluation of quantum dots applied as switchable layer in a light-controlled electrochemical sensor. Anal Bioanal Chem 2009; 396:1095-103. [DOI: 10.1007/s00216-009-3347-y] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2009] [Revised: 11/15/2009] [Accepted: 11/24/2009] [Indexed: 10/20/2022]
|
56
|
Ges IA, Baudenbacher F. Enzyme electrodes to monitor glucose consumption of single cardiac myocytes in sub-nanoliter volumes. Biosens Bioelectron 2009; 25:1019-24. [PMID: 19833499 DOI: 10.1016/j.bios.2009.09.018] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2009] [Revised: 09/09/2009] [Accepted: 09/11/2009] [Indexed: 01/25/2023]
Abstract
Monitoring the metabolic activity of cells in automated culture systems is one of the key features of micro-total-analysis-systems. We have developed a microfluidic device that allows us to trap single cardiac myocytes (SCMs) in sub-nanoliter volumes and incorporate amperometric glucose-sensing electrodes with working areas of 0.002 mm(2) to measure the glucose consumption of SCM. The miniaturized planar glucose electrodes were fabricated by spin coating platinum electrodes on glass substrates with a glutaraldehyde/enzyme solution and a protective Nafion membrane. The glucose electrodes demonstrate a high enzymatic activity characterized by an apparent Michaelis-Menten constant of 7.52+/-0.18 mM and a sensitivity of approximately 33.8 and approximately 13.2 mA/Mcm(2) at glucose concentration from 0-6 to 6-20 mM in Tyrode's solution, respectively. The response time of the glucose electrodes was between 5 and 15s, and the sensitivity of the electrodes did not degrade over a period of 8 weeks. A replica molded polydimethylsiloxane microfluidic device with a sub-nanoliter sensing volume was sealed to the glass substrate and aligned with the glucose microelectrodes. SCM can be trapped in the sensing volume above the glucose electrodes to measure the glucose consumption over time. The average glucose consumption of SCM was 0.211+/-0.097 mM/min (n=7) in Tyrode's solution with 5 mM of glucose.
Collapse
Affiliation(s)
- Igor A Ges
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235-1631, USA
| | | |
Collapse
|
57
|
Douglas ES, Hsiao SC, Onoe H, Bertozzi CR, Francis MB, Mathies RA. DNA-barcode directed capture and electrochemical metabolic analysis of single mammalian cells on a microelectrode array. LAB ON A CHIP 2009; 9:2010-5. [PMID: 19568668 PMCID: PMC2892333 DOI: 10.1039/b821690h] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
A microdevice is developed for DNA-barcode directed capture of single cells on an array of pH-sensitive microelectrodes for metabolic analysis. Cells are modified with membrane-bound single-stranded DNA, and specific single-cell capture is directed by the complementary strand bound in the sensor area of the iridium oxide pH microelectrodes within a microfluidic channel. This bifunctional microelectrode array is demonstrated for the pH monitoring and differentiation of primary T cells and Jurkat T lymphoma cells. Single Jurkat cells exhibited an extracellular acidification rate of 11 milli-pH min(-1), while primary T cells exhibited only 2 milli-pH min(-1). This system can be used to capture non-adherent cells specifically and to discriminate between visually similar healthy and cancerous cells in a heterogeneous ensemble based on their altered metabolic properties.
Collapse
Affiliation(s)
- Erik S Douglas
- UCSF/UC Berkeley Joint Graduate Group in Bioengineering, University of California, Berkeley, California 94720, USA.
| | | | | | | | | | | |
Collapse
|
58
|
Metabolic discrimination of select list agents by monitoring cellular responses in a multianalyte microphysiometer. SENSORS 2009; 9:2117-33. [PMID: 22574003 PMCID: PMC3345856 DOI: 10.3390/s90302117] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/07/2009] [Revised: 03/15/2009] [Accepted: 03/17/2009] [Indexed: 11/23/2022]
Abstract
Harnessing the potential of cells as complex biosensors promises the potential to create sensitive and selective detectors for discrimination of biodefense agents. Here we present toxin detection and suggest discrimination using cells in a multianalyte microphysiometer (MMP) that is capable of simultaneously measuring flux changes in four extracellular analytes (acidification rate, glucose uptake, oxygen uptake, and lactate production) in real-time. Differential short-term cellular responses were observed between botulinum neurotoxin A and ricin toxin with neuroblastoma cells, alamethicin and anthrax protective antigen with RAW macrophages, and cholera toxin, muscarine, 2,4-dinitro-phenol, and NaF with CHO cells. These results and the post exposure dynamics and metabolic recovery observed in each case suggest the usefulness of cell-based detectors to discriminate between specific analytes and classes of compounds in a complex matrix, and furthermore to make metabolic inferences on the cellular effects of the agents. This may be particularly valuable for classifying unknown toxins.
Collapse
|
59
|
Development of high throughput optical sensor array for on-line pH monitoring in micro-scale cell culture environment. Biomed Microdevices 2008; 11:265-73. [DOI: 10.1007/s10544-008-9233-0] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
60
|
Urbanski JP, Johnson MT, Craig DD, Potter DL, Gardner DK, Thorsen T. Noninvasive metabolic profiling using microfluidics for analysis of single preimplantation embryos. Anal Chem 2008; 80:6500-7. [PMID: 18661953 PMCID: PMC2990473 DOI: 10.1021/ac8010473] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Noninvasive analysis of metabolism at the single cell level will have many applications in evaluating cellular physiology. One clinically relevant application would be to determine the metabolic activities of embryos produced through assisted reproduction. There is increasing evidence that embryos with greater developmental capacity have distinct metabolic profiles. One of the standard techniques for evaluating embryonic metabolism has been to evaluate consumption and production of several key energetic substrates (glucose, pyruvate, and lactate) using microfluorometric enzymatic assays. These assays are performed manually using constriction pipets, which greatly limits the utility of this system. Through multilayer soft-lithography, we have designed a microfluidic device that can perform these assays in an automated fashion. Following manual loading of samples and enzyme cocktail reagents, this system performs sample and enzyme cocktail aliquotting, mixing of reagents, data acquisition, and data analysis without operator intervention. Optimization of design and operating regimens has resulted in the ability to perform serial measurements of glucose, pyruvate, and lactate in triplicate with submicroliter sample volumes within 5 min. The current architecture allows for automated analysis of 10 samples and intermittent calibration over a 3 h period. Standard curves generated for each metabolite have correlation coefficients that routinely exceed 0.99. With the use of a standard epifluorescent microscope and CCD camera, linearity is obtained with metabolite concentrations in the low micromolar range (low femtomoles of total analyte). This system is inherently flexible, being easily adapted for any NAD(P)H-based assay and scaled up in terms of sample ports. Open source JAVA-based software allows for simple alterations in routine algorithms. Furthermore, this device can be used as a standalone device in which media samples are loaded or be integrated into microfluidic culture systems for in line, real time metabolic evaluation. With the improved throughput and flexibility of this system, many barriers to evaluating metabolism of embryos and single cells are eliminated. As a proof of principle, metabolic activities of single murine embryos were evaluated using this device.
Collapse
Affiliation(s)
- John Paul Urbanski
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| | - Mark T. Johnson
- Fertility Laboratories of Colorado, Englewood, CO, 80110 USA
| | - David D. Craig
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| | - David L. Potter
- Fertility Laboratories of Colorado, Englewood, CO, 80110 USA
| | | | - Todd Thorsen
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| |
Collapse
|
61
|
Ciobanu M, Taylor DE, Wilburn JP, Cliffel DE. Glucose and lactate biosensors for scanning electrochemical microscopy imaging of single live cells. Anal Chem 2008; 80:2717-27. [PMID: 18345647 PMCID: PMC2836715 DOI: 10.1021/ac7021184] [Citation(s) in RCA: 65] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
We have developed glucose and lactate ultramicroelectrode (UME) biosensors based on glucose oxidase and lactate oxidase (with enzymes immobilized onto Pt UMEs by either electropolymerization or casting) for scanning electrochemical microscopy (SECM) and have determined their sensitivity to glucose and lactate, respectively. The results of our evaluations reveal different advantages for sensors constructed by each method: improved sensitivity and shorter manufacturing time for hand-casting, and increased reproducibility for electropolymerization. We have acquired amperometric approach curves (ACs) for each type of manufactured biosensor UME, and these ACs can be used as a means of positioning the UME above a substrate at a known distance. We have used the glucose biosensor UMEs to record profiles of glucose uptake above individual fibroblasts. Likewise, we have employed the lactate biosensor UMEs for recording the lactate production above single cancer cells with the SECM. We also show that oxygen respiration profiles for single cancer cells do not mimic cell topography, but are rather more convoluted, with a higher respiration activity observed at the points where the cell touches the Petri dish. These UME biosensors, along with the application of others already described in the literature, could prove to be powerful tools for mapping metabolic analytes, such as glucose, lactate, and oxygen, in single cancer cells.
Collapse
Affiliation(s)
- Madalina Ciobanu
- Department of Chemistry, Vanderbilt University, Nashville, TN 37235
| | - Dale E. Taylor
- Department of Chemistry and Life Science, United States Military Academy, West Point, NY 10996
| | | | - David E. Cliffel
- Department of Chemistry, Vanderbilt University, Nashville, TN 37235
| |
Collapse
|
62
|
Spegel C, Heiskanen A, Skjolding L, Emnéus J. Chip Based Electroanalytical Systems for Cell Analysis. ELECTROANAL 2008. [DOI: 10.1002/elan.200704130] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
63
|
Snider RM, Ciobanu M, Rue AE, Cliffel DE. A multiwalled carbon nanotube/dihydropyran composite film electrode for insulin detection in a microphysiometer chamber. Anal Chim Acta 2008; 609:44-52. [PMID: 18243872 PMCID: PMC2358927 DOI: 10.1016/j.aca.2007.12.032] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2007] [Revised: 12/18/2007] [Accepted: 12/19/2007] [Indexed: 12/26/2022]
Abstract
We have developed a multiwalled carbon nanotube/dihydropyran (MWCNT/DHP) composite sensor for the electrochemical detection of insulin in a microfluidic device. This sensor has been employed for physiological measurements of secreted insulin from pancreatic islets in a Cytosensor previously modified to be a multianalyte microphysiometer (MAMP). When compared with other established electrochemical insulin sensors, the MWCNT/DHP composite film sensor presented improved resistance to fluidic shear forces, while achieving enhanced electrode kinetics. In addition, the preparation of the composite film is straightforward and facile with a self-polymerizing monomer, DHP, used to add mechanical stability to the film. The sensor film was able to detect insulin concentrations as low as 1muM in the MAMP during calibration experiments. The MWCNT/DHP composite sensor has been successfully used for the direct detection of insulin secreted by islets in the microphysiometer.
Collapse
Affiliation(s)
- Rachel M. Snider
- Department of Chemistry, Vanderbilt University, Nashville, TN 37235-1822
| | - Madalina Ciobanu
- Department of Chemistry, Vanderbilt University, Nashville, TN 37235-1822
| | - Amy E. Rue
- Department of Chemistry, Vanderbilt University, Nashville, TN 37235-1822
| | - David E. Cliffel
- Department of Chemistry, Vanderbilt University, Nashville, TN 37235-1822
| |
Collapse
|
64
|
Surface modification of a perfluorinated ionomer using a glow discharge deposition method to control protein adsorption. Biomaterials 2007; 29:1356-66. [PMID: 18155292 DOI: 10.1016/j.biomaterials.2007.11.035] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2007] [Accepted: 11/24/2007] [Indexed: 11/23/2022]
Abstract
Nafion is the membrane material preferred for in situ glucose sensors. Unfortunately, surface properties of Nafion promote random protein adsorption and eventual foreign body encapsulation thus leading to loss of glucose signal over time. Here we detail surface modifications made by RF plasma deposition to Nafion with the intent to prevent random protein adsorption while providing enough functional sites (hydroxyl groups) to bind a biologically active peptide known to induce cellular adhesion (YRGDS). Nafion surfaces were modified by RF plasma polymerizing five different combinations of (1) tetraethylene glycol dimethyl ether (tetraglyme) and (2) 2-hydroxyethyl methacrylate (HEMA): pure tetraglyme, 2.5% HEMA with 97.5% tetraglyme, 5% HEMA with 95% tetraglyme, 10% HEMA with 90% tetraglyme, and pure HEMA. Resultant surfaces were characterized by XPS (low and high resolution), dynamic contact angle, and atomic force microscopy. Protein adsorption and retention was determined and correlated to surface layer composition. The ability to bind a cell adhesion peptide was also determined and correlated well with surface layer composition.
Collapse
|
65
|
Ceriotti L, Kob A, Drechsler S, Ponti J, Thedinga E, Colpo P, Ehret R, Rossi F. Online monitoring of BALB/3T3 metabolism and adhesion with multiparametric chip-based system. Anal Biochem 2007; 371:92-104. [PMID: 17709091 DOI: 10.1016/j.ab.2007.07.014] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2007] [Revised: 07/06/2007] [Accepted: 07/11/2007] [Indexed: 10/23/2022]
Abstract
A multiparametric chip-based system was employed to measure cell adhesion, metabolism, and response to metal compounds previously classified as cytotoxic in immortalized mouse fibroblasts (BALB/3T3 cell line). The system measures in parallel, online, and in label-free conditions the extracellular acidification rates (with pH-sensitive field effect transistors [ISFETs]), the cellular oxygen consumption (with amperometric electrode structures [Clark-type sensors]), and cell adhesion (with impedimetric interdigitated electrode structures [IDESs]). The experimental protocol was optimized to monitor metabolism and adhesion of the BALB/3T3 cell line. A total of 70,000 cells and a bicarbonate buffer-free running low-glucose Dulbecco's modified Eagle's medium (DMEM) containing 10% fetal clone serum III and 1mM Hepes were selected to maintain cells in good conditions on the chip during the measurements performed under perfusion conditions. Cells were exposed to sodium arsenite, cadmium chloride, and cis-platinum at concentrations ranging from 1 to 100 microM. The kinetics of cell response to these compounds was analyzed and suggests that the Clark-type sensors can be more sensitive than IDESs and ISFETs in detecting the presence of high chemical concentration when short exposure times (i.e., 2h) are considered. The cytotoxicity data obtained from the online measurements of acidification, respiration, and adhesion at 24h compare well, in terms of half-inhibition concentration values (IC(50)), with the ones obtained using 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) test and colony-forming efficiency (CFE) assay. The results show a good sensitivity of the system combined with the advantages of the online and label-free detection methods that allow following cell status before, during, and after the treatment in the same experiment.
Collapse
Affiliation(s)
- L Ceriotti
- Nanotechnology and Molecular Imaging Unit, Institute for Health and Consumer Protection, Joint Research Centre, I-21020 Ispra, Italy
| | | | | | | | | | | | | | | |
Collapse
|
66
|
Lin Y, Liu K, Yu P, Xiang L, Li X, Mao L. A Facile Electrochemical Method for Simultaneous and On-Line Measurements of Glucose and Lactate in Brain Microdialysate with Prussian Blue as the Electrocatalyst for Reduction of Hydrogen Peroxide. Anal Chem 2007; 79:9577-83. [DOI: 10.1021/ac070966u] [Citation(s) in RCA: 103] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Yuqing Lin
- Beijing National Laboratory for Molecular Sciences, Institute of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100080, China, and Graduate School of the CAS, Beijing 100039, China
| | - Kun Liu
- Beijing National Laboratory for Molecular Sciences, Institute of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100080, China, and Graduate School of the CAS, Beijing 100039, China
| | - Ping Yu
- Beijing National Laboratory for Molecular Sciences, Institute of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100080, China, and Graduate School of the CAS, Beijing 100039, China
| | - Ling Xiang
- Beijing National Laboratory for Molecular Sciences, Institute of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100080, China, and Graduate School of the CAS, Beijing 100039, China
| | - Xianchan Li
- Beijing National Laboratory for Molecular Sciences, Institute of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100080, China, and Graduate School of the CAS, Beijing 100039, China
| | - Lanqun Mao
- Beijing National Laboratory for Molecular Sciences, Institute of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100080, China, and Graduate School of the CAS, Beijing 100039, China
| |
Collapse
|
67
|
Abstract
Systems biology, possibly the latest sub-discipline of biology, has arisen as a result of the shockwave of genomic and proteomic data that has appeared in the past few years. However, despite ubiquitous initiatives that carry this label, there is no precise definition of systems biology other than the implication of a new, all-encompassing, multidisciplinary endeavor. Here we propose that systems biology is more than the integration of biology with methods of the physical and computational sciences, and also more than the expansion of the single-pathway approach to embracing genome-scale networks. It is the discipline that specifically addresses the fundamental properties of the complexity that living systems represent. To facilitate the discussion, we dissect and project the multifaceted systems complexity of living organisms into five dimensions: (1) molecular complexity; (2) structural complexity; (3) temporal complexity; (4) abstraction and emergence; and (5) algorithmic complexity. This "five-dimensional space" may provide a framework for comparing, classifying, and complementing the vast diversity of existing systems biology programs and their goals, and will also give a glimpse of the magnitude of the scientific problems associated with unraveling the ultimate mysteries of life.
Collapse
Affiliation(s)
- S Huang
- Harvard Medical School, Department of Surgery and Vascular Biology Program, Karp 11-212, Children's Hospital, 300 Longwood Avenue, Boston, 02115 MA, USA.
| | | |
Collapse
|
68
|
Chapter 5 Light-addressable potentiometric sensors (LAPS): recent trends and applications. ACTA ACUST UNITED AC 2007. [DOI: 10.1016/s0166-526x(06)49005-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
69
|
Mestres P, Morguet A, Schmidt W, Kob A, Thedinga E. A New Method to Assess Drug Sensitivity on Breast Tumor Acute Slices Preparation. Ann N Y Acad Sci 2006; 1091:460-9. [PMID: 17341636 DOI: 10.1196/annals.1378.088] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A method for assessing tumor drug sensitivity is described that is based on preparation of tissue slices and use of silicon chips equipped with electrochemical sensors (multisensor array). The tumor slices (200-300 microM thick) are prepared after surgery and incubated in a medium for recovery after slicing. The advantage, compared to other preparations, is that the original three-dimensional structure is retained. Multisensor arrays measure: (a) pericellular acidification (anaerobic metabolism) and (b) oxygen consumption (respiration). The innovative aspect is that such measurements can be made online, as opposed to using a large battery of endpoint tests on cell vitality and proliferation. Electron microscopy of slices serves to determine cell density and structure and induction of apoptosis/necrosis. Slices of more than 200 breast tumors were used. Metabolic activity was inhibited by sodium fluoride, which reduces glycolysis, and potassium cyanide, which inhibits respiration. These changes are thus reflected in the curves of acidification and oxygen consumption. In other experiments the cytostatic Taxol, an anticytoskeletal agent, was used showing dose and time-dependent effects on acidification and oxygen consumption. In conclusion, the method presented here, is able to provide information on drug sensitivity of a tumor, which aids in designing individualized therapy and is used for drug screening.
Collapse
Affiliation(s)
- Pedro Mestres
- Department of Anatomy and Cell Biology, University Hospital, Building 61, University of Saarland, D-66421 Homburg/Saar, Germany.
| | | | | | | | | |
Collapse
|
70
|
Wikswo JP, Prokop A, Baudenbacher F, Cliffel D, Csukas B, Velkovsky M. Engineering challenges of BioNEMS: the integration of microfluidics, micro- and nanodevices, models and external control for systems biology. ACTA ACUST UNITED AC 2006; 153:81-101. [PMID: 16948492 DOI: 10.1049/ip-nbt:20050045] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Systems biology, i.e. quantitative, postgenomic, postproteomic, dynamic, multiscale physiology, addresses in an integrative, quantitative manner the shockwave of genetic and proteomic information using computer models that may eventually have 10(6) dynamic variables with non-linear interactions. Historically, single biological measurements are made over minutes, suggesting the challenge of specifying 10(6) model parameters. Except for fluorescence and micro-electrode recordings, most cellular measurements have inadequate bandwidth to discern the time course of critical intracellular biochemical events. Micro-array expression profiles of thousands of genes cannot determine quantitative dynamic cellular signalling and metabolic variables. Major gaps must be bridged between the computational vision and experimental reality. The analysis of cellular signalling dynamics and control requires, first, micro- and nano-instruments that measure simultaneously multiple extracellular and intracellular variables with sufficient bandwidth; secondly, the ability to open existing internal control and signalling loops; thirdly, external BioMEMS micro-actuators that provide high bandwidth feedback and externally addressable intracellular nano-actuators; and, fourthly, real-time, closed-loop, single-cell control algorithms. The unravelling of the nested and coupled nature of cellular control loops requires simultaneous recording of multiple single-cell signatures. Externally controlled nano-actuators, needed to effect changes in the biochemical, mechanical and electrical environment both outside and inside the cell, will provide a major impetus for nanoscience.
Collapse
Affiliation(s)
- J P Wikswo
- Vanderbilt Institute for Integrative Biosystems Research & Education, Nashville, TN 37235, USA.
| | | | | | | | | | | |
Collapse
|
71
|
Leegsma-Vogt G, Venema K, Brouwer N, Gramsbergen JB, Copray S, Korf J. Quantitative on-line monitoring of cellular glucose and lactate metabolism in vitro with slow perfusion. Anal Chem 2006; 76:5431-5. [PMID: 15362903 DOI: 10.1021/ac040057u] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
An on-line in vitro perfusion technique is described that allows the continuous quantification of cellular glucose metabolism in vitro. Using biosensor technology, we measure glucose and lactate metabolism at a minute-to-minute time resolution for periods up to several days. The application of our perfusion-detection technique for in vitro monitoring is demonstrated in a wide variety of cells, including primary neuronal and astroglia cultures, yeast cells, and human lymphocytes. The method shows that variations in oxygen delivery or exposure to a noncompetitive pseudosubstrate (here 2-deoxyglucose) affects normal glucose metabolism. The innovative advantage of the present system is that, in contrast to other devices including a recently described system, metabolism per cell can be quantified. The potential of in vitro on-line monitoring is discussed for application in studying normal and abnormal metabolism, toxic and nontoxic drug effects, and human tissue biopsies.
Collapse
Affiliation(s)
- Gea Leegsma-Vogt
- Department of Psychiatry, Section Biological Psychiatry, University of Groningen, Groningen, The Netherlands
| | | | | | | | | | | |
Collapse
|
72
|
Eklund SE, Snider RM, Wikswo J, Baudenbacher F, Prokop A, Cliffel DE. Multianalyte microphysiometry as a tool in metabolomics and systems biology. J Electroanal Chem (Lausanne) 2006. [DOI: 10.1016/j.jelechem.2005.11.024] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
73
|
Wilson GS, Gifford R. Biosensors for real-time in vivo measurements. Biosens Bioelectron 2005; 20:2388-403. [PMID: 15854814 DOI: 10.1016/j.bios.2004.12.003] [Citation(s) in RCA: 363] [Impact Index Per Article: 19.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2004] [Revised: 11/01/2004] [Accepted: 12/02/2004] [Indexed: 11/29/2022]
Abstract
The current status of sensors capable of continuous measurement of analytes in biological media is reviewed. This review containing 173 references deals with devices whose use in single cells, tissue slices, animal models and humans has been demonstrated. In addition to sensors specific for glucose, lactate, glutamate, pyruvate, choline and acetylcholine, insights obtained from monitoring nitric oxide, Na(+), K(+), Ca(2+), and dopamine are presented. Performance criteria for sensor performance are described as is the subject of biosensor calibration. Biocompatibility issues are dealt with in some detail as is the status of continuous blood glucose monitoring in humans.
Collapse
Affiliation(s)
- George S Wilson
- Department of Chemistry, University of Kansas, Malott Hall, Lawrence, KS 66045, USA.
| | | |
Collapse
|