51
|
Hu JB, Chen SY, Wu JT, Chen YC, Urban PL. Automated system for extraction and instantaneous analysis of millimeter-sized samples. RSC Adv 2014. [DOI: 10.1039/c3ra48023b] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
|
52
|
A high-throughput microdialysis–parallel solid phase extraction–inductively coupled plasma mass spectrometry hyphenated system for continuous monitoring of extracellular metal ions in living rat brain. J Chromatogr A 2014; 1326:73-9. [DOI: 10.1016/j.chroma.2013.12.047] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2013] [Revised: 12/06/2013] [Accepted: 12/14/2013] [Indexed: 02/08/2023]
|
53
|
Nie J, Kennedy RT. Capillary liquid chromatography fraction collection and postcolumn reaction using segmented flow microfluidics. J Sep Sci 2013; 36:3471-7. [PMID: 24039151 PMCID: PMC5641422 DOI: 10.1002/jssc.201300725] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2013] [Revised: 08/07/2013] [Accepted: 08/18/2013] [Indexed: 11/08/2022]
Abstract
A challenge for capillary LC (cLC) is fraction collection and the manipulation of fractions from microscale columns. An emerging approach is the use of segmented flow or droplet technology to perform such tasks. In this work, a fraction collection and postcolumn reaction system based on segmented flow was developed for the gradient cLC of proteins. In the system, column effluent and immiscible oil are pumped into separate arms of a tee resulting in regular fractions of effluent segmented by oil. Fractions were generated at 1 Hz corresponding to 5 nL volumes. The fraction collection rate was high enough to generate over 30 fractions per peak and preserve chromatographic resolution achieved for a five-protein test mixture. The resulting fractions could be stored and subsequently derivatized for fluorescence detection by pumping them into a second tee where naphthalene dicarboxyaldehyde, a fluorogenic reagent, was pumped into a second arm and added to each fraction. Proteins were derivatized within the droplets enabling postcolumn fluorescence detection of the proteins. The experiments demonstrate that fraction collection from cLC by segmented flow can be extended to proteins. Further, they illustrate a potential workflow for protein analysis based on postcolumn derivatization for fluorescence detection.
Collapse
Affiliation(s)
- Jing Nie
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109
| | - Robert T. Kennedy
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109
- Department of Pharmacology, University of Michigan, Ann Arbor, Michigan 48109
| |
Collapse
|
54
|
Kennedy RT. Emerging trends in in vivo neurochemical monitoring by microdialysis. Curr Opin Chem Biol 2013; 17:860-7. [PMID: 23856056 DOI: 10.1016/j.cbpa.2013.06.012] [Citation(s) in RCA: 86] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2013] [Accepted: 06/11/2013] [Indexed: 12/31/2022]
Abstract
Mapping chemical dynamics in the brain of live subjects is a challenging but highly rewarding goal because it allows neurotransmitter fluctuations to be related to behavior, drug effects, and disease states. A popular method for such measurements is microdialysis sampling coupled to analytical measurements. This method has become well-established for monitoring low molecular weight neurotransmitters, metabolites, and drugs, especially in pharmacological and pharmacokinetic studies. Recent technological developments which improve the temporal and spatial resolution of the methods will enable it to be used for studying behavior and small brain nuclei. Better assays allow monitoring more neurotransmitters simultaneously. Extension to analysis of aggregating proteins like amyloid β is proving extremely useful for uncovering the roles of these molecules and how they contribute to neurodegenerative diseases.
Collapse
Affiliation(s)
- Robert T Kennedy
- Departments of Chemistry and Pharmacology, University of Michigan, Ann Arbor, MI, United States.
| |
Collapse
|
55
|
Rupert AE, Ou Y, Sandberg M, Weber SG. Electroosmotic push-pull perfusion: description and application to qualitative analysis of the hydrolysis of exogenous galanin in organotypic hippocampal slice cultures. ACS Chem Neurosci 2013; 4:838-48. [PMID: 23614879 DOI: 10.1021/cn400082d] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
We demonstrate here a method that perfuses a small region of an organotypic hippocampal culture with a solution containing an enzyme substrate, a neuropeptide. Perfusate containing hydrolysis products is continually collected and subsequently analyzed for the products of the enzymatic degradation of the peptide substrate. The driving force for perfusion is an electric field. The fused silica capillaries used as "push" and "pull" or "source" and "collection" capillaries have a ζ-potential that is negative and greater in magnitude than the tissue's ζ-potential. Thus, depending on the magnitudes of particular dimensions, the electroosmotic flow in the capillaries augments the fluid velocity in the tissue. The flow rate is not directly measured; however, we determine it using a finite-element approach. We have determined the collection efficiency of the system using an all d-amino acid internal standard. The flow rates are low, in the nL/min range, and adjustable by controlling the current or voltage in the system. The collection efficiency of the d-amino acid peptide internal standard is variable, increasing with increased current and thus electroosmotic flow rate. The collection efficiency can be rationalized in the context of a Peclet number. Electroosmotic push-pull perfusion of the neuropeptide galanin (gal1-29) through the extracellular space of an organotypic hippocampal culture results in its hydrolysis by ectopeptidase reactions occurring in the extracellular space. The products of hydrolysis were identified by MALDI-MS. Experiments at two levels of current (8-12 μA and 19-40 μA) show that the probability of seeing hydrolysis products (apparently from aminopeptidases) is greater in the Cornu Ammonis area 3 (CA3) than in the Cornu Ammonis area 1 (CA1) in the higher current experiments. In the lower current experiments, shorter peptide products of aminopeptidases (gal13-29 to gal20-19) are seen with greater frequency in CA3 than in CA1 but there is no statistically significant difference for longer peptides (gal3-29 to gal12-29).
Collapse
Affiliation(s)
- Amy E. Rupert
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania
15260, United States
| | - Y. Ou
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania
15260, United States
| | - M. Sandberg
- Department
of Medical Biochemistry and Cell Biology, Gothenburg University, Gothenburg, S 405 30 Sweden
| | - S. G. Weber
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania
15260, United States
| |
Collapse
|
56
|
Rupert AE, Ou Y, Sandberg M, Weber SG. Assessment of tissue viability following electroosmotic push-pull perfusion from organotypic hippocampal slice cultures. ACS Chem Neurosci 2013; 4:849-57. [PMID: 23639590 PMCID: PMC3656745 DOI: 10.1021/cn4000814] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
We have developed a novel sampling technique that allows both introduction and removal of fluid from the extracellular space of living tissue. This method is based on the fluidics of push-pull perfusion but flow is driven by electroosmosis. We have applied this method to organotypic hippocampal cultures. A source capillary is inserted into the tissue and a collection capillary is in contact with the tissue surface through a thin layer of fluid. A voltage is applied across the proximal ends of source and collection capillary. In the applied field, fluid will move from source, into the tissue, and then be collected. In this process, damage to cells may occur. To understand better what sampling conditions influence damage most, we tested various sampling geometries and applied voltages, quantifying damage 16-24 h later using propidium iodide as a cell death marker. We found that damage correlates with both voltage drop and power dissipated in the tissue, but that voltage drop is a better indicator of damage when comparing models in which capillary arrangement and length are different.
Collapse
Affiliation(s)
- Amy E Rupert
- Department of Chemistry, University of Pittsburgh, Pittsburgh, PA 15260, United States
| | | | | | | |
Collapse
|
57
|
Croushore CA, Sweedler JV. Microfluidic systems for studying neurotransmitters and neurotransmission. LAB ON A CHIP 2013; 13:1666-76. [PMID: 23474943 PMCID: PMC3632338 DOI: 10.1039/c3lc41334a] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Neurotransmitters and neuromodulators are molecules within the nervous system that play key roles in cell-to-cell communication. Upon stimulation, neurons release these signaling molecules, which then act at local or distant locations to elicit a physiological response. Ranging from small molecules, such as diatomic gases and amino acids, to larger peptides, these chemical messengers are involved in many functional processes including growth, reproduction, memory and behavior. Understanding signaling molecules and the conditions that govern their release in healthy or damaged networks promises to deliver insights into neural network formation and function. Microfluidic devices can provide optimal cell culture conditions, reduced volume systems, and precise control over the chemical and physical nature of the extracellular environment, making them well-suited for studying neurotransmission and other forms of cell-to-cell signaling. Here we review selected microfluidic approaches that are suitable for monitoring cell-to-cell signaling molecules. We highlight devices that improve in vivo sample collection as well as compartmentalized devices designed to isolate individual neurons or co-cultures in vitro, including a focus on systems used for studying neural injury and regeneration, and devices that allow selective chemical stimulations and the characterization of released molecules.
Collapse
Affiliation(s)
- Callie A. Croushore
- Department of Chemistry and the Beckman Institute for Advanced Science
and Technology, University of Illinois at Urbana-Champaign, Urbana IL 61801,
USA
| | - Jonathan V. Sweedler
- Department of Chemistry and the Beckman Institute for Advanced Science
and Technology, University of Illinois at Urbana-Champaign, Urbana IL 61801,
USA
| |
Collapse
|
58
|
Lee WH, Slaney TR, Hower RW, Kennedy RT. Microfabricated sampling probes for in vivo monitoring of neurotransmitters. Anal Chem 2013; 85:3828-31. [PMID: 23547793 PMCID: PMC3642770 DOI: 10.1021/ac400579x] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Microfabricated fluidic systems have emerged as a powerful approach for chemical analysis. Relatively unexplored is the use of microfabrication to create sampling probes. We have developed a sampling probe microfabricated in Si by bulk micromachining and lithography. The probe is 70 μm wide by 85 μm thick by 11 mm long and incorporates two buried channels that are 20 μm in diameter. The tip of the probe has two 20 μm holes where fluid is ejected or collected for sampling. Utility of the probe was demonstrated by sampling from the brain of live rats. For sampling, artificial cerebral spinal fluid was infused in through one channel at 50 nL/min while sample was withdrawn at the same flow rate from the other channel. Analysis of resulting fractions collected every 20 min from the striatum of rats by liquid chromatography with mass spectrometry demonstrated reliable detection of 17 neurotransmitters and metabolites. The small probe dimensions suggest it is less perturbing to tissue and can be used to sample smaller brain nuclei than larger sampling devices, such as microdialysis probes. This sampling probe may have other applications such as sampling from cells in culture. The use of microfabrication may also enable incorporation of electrodes for electrochemical or electrophysiological recording and other channels that enable more complex sample preparation on the device.
Collapse
Affiliation(s)
- Woong Hee Lee
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109
| | - Thomas R. Slaney
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109
| | - Robert W. Hower
- Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI 48109
| | - Robert T. Kennedy
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109
- Department of Pharmacology, University of Michigan, Ann Arbor, MI 48109
| |
Collapse
|
59
|
|
60
|
Slaney TR, Mabrouk OS, Porter-Stransky KA, Aragona BJ, Kennedy RT. Chemical gradients within brain extracellular space measured using low flow push-pull perfusion sampling in vivo. ACS Chem Neurosci 2013; 4:321-9. [PMID: 23421683 DOI: 10.1021/cn300158p] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
Abstract
Although populations of neurons are known to vary on the micrometer scale, little is known about whether basal concentrations of neurotransmitters also vary on this scale. We used low-flow push-pull perfusion to test if such chemical gradients exist between several small brain nuclei. A miniaturized polyimide-encased push-pull probe was developed and used to measure basal neurotransmitter spatial gradients within brain of live animals with 0.004 mm(3) resolution. We simultaneously measured dopamine (DA), norepinephrine, serotonin (5-HT), glutamate, γ-aminobutyric acid (GABA), aspartate (Asp), glycine (Gly), acetylcholine (ACh), and several neurotransmitter metabolites. Significant differences in basal concentrations between midbrain regions as little as 200 μm apart were observed. For example, dopamine in the ventral tegmental area (VTA) was 4.8 ± 1.5 nM but in the red nucleus was 0.5 ± 0.2 nM. Regions of high glutamate concentration and variability were found within the VTA of some individuals, suggesting hot spots of glutamatergic activity. Measurements were also made within the nucleus accumbens core and shell. Differences were not observed in dopamine and 5-HT in the core and shell; but their metabolites homovanillic acid (460 ± 60 nM and 130 ± 60 nM respectively) and 5-hydroxyindoleacetic acid (720 ± 200 nM and 220 ± 50 nM respectively) did differ significantly, suggesting differences in dopamine and 5-HT activity in these brain regions. Maintenance of these gradients depends upon a variety of mechanisms. Such gradients likely underlie highly localized effects of drugs and control of behavior that have been found using other techniques.
Collapse
Affiliation(s)
- Thomas R. Slaney
- Department of Chemistry, University of Michigan, 930 N. University Ave. Ann
Arbor, Michigan 48109, United States
| | - Omar S. Mabrouk
- Department of Chemistry, University of Michigan, 930 N. University Ave. Ann
Arbor, Michigan 48109, United States
| | - Kirsten A. Porter-Stransky
- Department of Psychology, University of Michigan, 530 Church St., Ann Arbor,
Michigan 48109, United States
| | - Brandon J. Aragona
- Department of Psychology, University of Michigan, 530 Church St., Ann Arbor,
Michigan 48109, United States
| | - Robert T. Kennedy
- Department of Chemistry, University of Michigan, 930 N. University Ave. Ann
Arbor, Michigan 48109, United States
| |
Collapse
|
61
|
|
62
|
Sun S, Slaney TR, Kennedy RT. Label free screening of enzyme inhibitors at femtomole scale using segmented flow electrospray ionization mass spectrometry. Anal Chem 2012; 84:5794-800. [PMID: 22656268 DOI: 10.1021/ac3011389] [Citation(s) in RCA: 72] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Droplet-based microfluidics is an attractive platform for screening and optimizing chemical reactions. Using this approach, it is possible to reliably manipulate nanoliter volume samples and perform operations such as reagent addition with high precision, automation, and throughput. Most studies using droplet microfluidics have relied on optical techniques to detect the reaction; however, this requires engineering color or fluorescence change into the reaction being studied. In this work, we couple electrospray ionization mass spectrometry (ESI-MS) to nanoliter scale segmented flow reactions to enable direct (label-free) analysis of reaction products. The system is applied to a screen of inhibitors for cathepsin B. In this approach, solutions of test compounds (including three known inhibitors) are arranged as an array of nanoliter droplets in a tube segmented by perfluorodecalin. The samples are pumped through a series of tees to add enzyme, substrate (peptides), and quenchant. The resulting reaction mixtures are then infused into a metal-coated, fused silica ESI emitter for MS analysis. The system has potential for high-throughput as reagent addition steps are performed at 0.7 s per sample and ESI-MS at up to 1.2 s per sample. Carryover is inconsequential in the ESI emitter and between 2 and 9% per reagent addition depending on the tee utilized. The assay was reliable with a Z-factor of ~0.8. The method required 0.8 pmol of test compound, 1.6 pmol of substrate, and 5 fmol of enzyme per reaction. Segmented flow ESI-MS allows direct, label free screening of reactions at good throughput and ultralow sample consumption.
Collapse
Affiliation(s)
- Shuwen Sun
- University of Michigan, Department of Chemistry, Ann Arbor, Michigan 48109, United States
| | | | | |
Collapse
|
63
|
Li X, Zhao L, Chen Z, Lin Y, Yu P, Mao L. Continuous Electrochemical Monitoring of Extracellular Lactate Production from Neonatal Rat Cardiomyocytes following Myocardial Hypoxia. Anal Chem 2012; 84:5285-91. [DOI: 10.1021/ac300354z] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Xianchan Li
- Beijing National
Laboratory for Molecular Sciences,
Key Laboratory of Analytical Chemistry for Living Biosystems, Institute
of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100190, China
| | - Lingzhi Zhao
- Beijing National
Laboratory for Molecular Sciences,
Key Laboratory of Analytical Chemistry for Living Biosystems, Institute
of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100190, China
| | - Zhenling Chen
- Beijing National
Laboratory for Molecular Sciences,
Key Laboratory of Analytical Chemistry for Living Biosystems, Institute
of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100190, China
| | - Yuqing Lin
- Beijing National
Laboratory for Molecular Sciences,
Key Laboratory of Analytical Chemistry for Living Biosystems, Institute
of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100190, China
| | - Ping Yu
- Beijing National
Laboratory for Molecular Sciences,
Key Laboratory of Analytical Chemistry for Living Biosystems, Institute
of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100190, China
| | - Lanqun Mao
- Beijing National
Laboratory for Molecular Sciences,
Key Laboratory of Analytical Chemistry for Living Biosystems, Institute
of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100190, China
| |
Collapse
|
64
|
Song P, Hershey ND, Mabrouk OS, Slaney TR, Kennedy RT. Mass spectrometry "sensor" for in vivo acetylcholine monitoring. Anal Chem 2012; 84:4659-64. [PMID: 22616788 DOI: 10.1021/ac301203m] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Developing sensors for in vivo chemical monitoring is a daunting challenge. An alternative approach is to couple sampling methods with online analytical techniques; however, such approaches are generally hampered by lower temporal resolution and slow analysis. In this work, microdialysis sampling was coupled with segmented flow electrospray ionization mass spectrometry (ESI-MS) to perform in vivo chemical monitoring. The use of segmented flow to prevent Taylor dispersion of collected zones and rapid analysis with direct ESI-MS allowed 5 s temporal resolution to be achieved. The MS "sensor" was applied to monitor acetylcholine in the brain of live rats. The detection limit of 5 nM was sufficient to monitor basal acetylcholine as well as dynamic changes elicited by microinjection of neostigmine, an inhibitor of acetylcholinesterase, that evoked rapid increases in acetycholine and tetrodotoxin, a blocker of Na(+) channels, that lowered the acetylcholine concentration. The versatility of the sensor was demonstrated by simultaneously monitoring metabolites and infused drugs.
Collapse
Affiliation(s)
- Peng Song
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| | | | | | | | | |
Collapse
|
65
|
Li PH, Ting H, Chen YC, Urban PL. Recording temporal characteristics of convection currents by continuous and segmented-flow sampling. RSC Adv 2012. [DOI: 10.1039/c2ra21695g] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
|