51
|
Berg B, Cortazar B, Tseng D, Ozkan H, Feng S, Wei Q, Chan RYL, Burbano J, Farooqui Q, Lewinski M, Di Carlo D, Garner OB, Ozcan A. Cellphone-Based Hand-Held Microplate Reader for Point-of-Care Testing of Enzyme-Linked Immunosorbent Assays. ACS NANO 2015; 9:7857-66. [PMID: 26159546 DOI: 10.1021/acsnano.5b03203] [Citation(s) in RCA: 214] [Impact Index Per Article: 23.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Standard microplate based enzyme-linked immunosorbent assays (ELISA) are widely utilized for various nanomedicine, molecular sensing, and disease screening applications, and this multiwell plate batched analysis dramatically reduces diagnosis costs per patient compared to nonbatched or nonstandard tests. However, their use in resource-limited and field-settings is inhibited by the necessity for relatively large and expensive readout instruments. To mitigate this problem, we created a hand-held and cost-effective cellphone-based colorimetric microplate reader, which uses a 3D-printed opto-mechanical attachment to hold and illuminate a 96-well plate using a light-emitting-diode (LED) array. This LED light is transmitted through each well, and is then collected via 96 individual optical fibers. Captured images of this fiber-bundle are transmitted to our servers through a custom-designed app for processing using a machine learning algorithm, yielding diagnostic results, which are delivered to the user within ∼1 min per 96-well plate, and are visualized using the same app. We successfully tested this mobile platform in a clinical microbiology laboratory using FDA-approved mumps IgG, measles IgG, and herpes simplex virus IgG (HSV-1 and HSV-2) ELISA tests using a total of 567 and 571 patient samples for training and blind testing, respectively, and achieved an accuracy of 99.6%, 98.6%, 99.4%, and 99.4% for mumps, measles, HSV-1, and HSV-2 tests, respectively. This cost-effective and hand-held platform could assist health-care professionals to perform high-throughput disease screening or tracking of vaccination campaigns at the point-of-care, even in resource-poor and field-settings. Also, its intrinsic wireless connectivity can serve epidemiological studies, generating spatiotemporal maps of disease prevalence and immunity.
Collapse
Affiliation(s)
- Brandon Berg
- Electrical Engineering Department, University of California , Los Angeles, California 90095, United States
- Physics and Astronomy Department, University of California , Los Angeles, California 90095, United States
| | - Bingen Cortazar
- Electrical Engineering Department, University of California , Los Angeles, California 90095, United States
| | - Derek Tseng
- Electrical Engineering Department, University of California , Los Angeles, California 90095, United States
- Bioengineering Department, University of California , Los Angeles, California 90095, United States
| | - Haydar Ozkan
- Electrical Engineering Department, University of California , Los Angeles, California 90095, United States
- Bioengineering Department, University of California , Los Angeles, California 90095, United States
- Biomedical Engineering Department, Fatih Sultan Mehmet Vakif University , Istanbul 34445, Turkey
| | - Steve Feng
- Electrical Engineering Department, University of California , Los Angeles, California 90095, United States
| | - Qingshan Wei
- Electrical Engineering Department, University of California , Los Angeles, California 90095, United States
- Bioengineering Department, University of California , Los Angeles, California 90095, United States
| | - Raymond Yan-Lok Chan
- Electrical Engineering Department, University of California , Los Angeles, California 90095, United States
| | - Jordi Burbano
- Electrical Engineering Department, University of California , Los Angeles, California 90095, United States
| | - Qamar Farooqui
- Electrical Engineering Department, University of California , Los Angeles, California 90095, United States
| | - Michael Lewinski
- Bioengineering Department, University of California , Los Angeles, California 90095, United States
- Roche Molecular Systems, Inc. , Pleasanton, California 94588, United States
| | - Dino Di Carlo
- Bioengineering Department, University of California , Los Angeles, California 90095, United States
- California NanoSystems Institute (CNSI), University of California , Los Angeles, California 90095, United States
- Jonsson Comprehensive Cancer Center, University of California , Los Angeles, California 90095, United States
| | - Omai B Garner
- Department of Pathology and Laboratory Medicine, David Geffen School of Medicine, University of California , Los Angeles, California 90095, United States
| | - Aydogan Ozcan
- Electrical Engineering Department, University of California , Los Angeles, California 90095, United States
- Bioengineering Department, University of California , Los Angeles, California 90095, United States
- California NanoSystems Institute (CNSI), University of California , Los Angeles, California 90095, United States
- Department of Surgery, David Geffen School of Medicine, University of California , Los Angeles, California 90095, United States
| |
Collapse
|
52
|
Singh H, Shimojima M, Shiratori T, An LV, Sugamata M, Yang M. Application of 3D Printing Technology in Increasing the Diagnostic Performance of Enzyme-Linked Immunosorbent Assay (ELISA) for Infectious Diseases. SENSORS 2015; 15:16503-15. [PMID: 26184194 PMCID: PMC4541890 DOI: 10.3390/s150716503] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/23/2015] [Revised: 06/24/2015] [Accepted: 07/06/2015] [Indexed: 01/18/2023]
Abstract
Enzyme-linked Immunosorbent Assay (ELISA)-based diagnosis is the mainstay for measuring antibody response in infectious diseases and to support pathogen identification of potential use in infectious disease outbreaks and clinical care of individual patients. The development of laboratory diagnostics using readily available 3D printing technologies provides a timely opportunity for further expansion of this technology into immunodetection systems. Utilizing available 3D printing platforms, a ‘3D well’ was designed and developed to have an increased surface area compared to those of 96-well plates. The ease and rapidity of the development of the 3D well prototype provided an opportunity for its rapid validation through the diagnostic performance of ELISA in infectious disease without modifying current laboratory practices for ELISA. The improved sensitivity of the 3D well of up to 2.25-fold higher compared to the 96-well ELISA provides a potential for the expansion of this technology towards miniaturization and Lab-On-a-Chip platforms to reduce time, volume of reagents and samples needed for such assays in the laboratory diagnosis of infectious and other diseases including applications in other disciplines.
Collapse
Affiliation(s)
- Harpal Singh
- Department of Intelligent Mechanical Systems, Graduate School of System Design, Tokyo Metropolitan University, 6-6 Asahigaoka, Hino, Tokyo 191-0065, Japan.
- Department of Virology 1, National Institute of Infectious Diseases, 4-7-1 Gakuen, Musashimurayama, Tokyo 208-0011, Japan.
| | - Masayuki Shimojima
- Department of Virology 1, National Institute of Infectious Diseases, 4-7-1 Gakuen, Musashimurayama, Tokyo 208-0011, Japan. shimoji-@nih.go.jp
| | - Tomomi Shiratori
- Department of Intelligent Mechanical Systems, Graduate School of System Design, Tokyo Metropolitan University, 6-6 Asahigaoka, Hino, Tokyo 191-0065, Japan.
| | - Le Van An
- Department of Microbiology, Hue University of Medicine and Pharmacy, 6 Ngo Quyen St., Hue 47000, Vietnam.
| | - Masami Sugamata
- Department of Microbiology, Hue University of Medicine and Pharmacy, 6 Ngo Quyen St., Hue 47000, Vietnam.
- Department of Hygiene and Public Health, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 1-1 Minami-Osawa, Hachioji, Tokyo 192-0397, Japan.
| | - Ming Yang
- Department of Intelligent Mechanical Systems, Graduate School of System Design, Tokyo Metropolitan University, 6-6 Asahigaoka, Hino, Tokyo 191-0065, Japan.
| |
Collapse
|
53
|
Guha S, Warsinke A, Tientcheu CM, Schmalz K, Meliani C, Wenger C. Label free sensing of creatinine using a 6 GHz CMOS near-field dielectric immunosensor. Analyst 2015; 140:3019-27. [PMID: 25782697 DOI: 10.1039/c4an02194k] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
In this work we present a CMOS high frequency direct immunosensor operating at 6 GHz (C-band) for label free determination of creatinine. The sensor is fabricated in standard 0.13 μm SiGe:C BiCMOS process. The report also demonstrates the ability to immobilize creatinine molecules on a Si3N4 passivation layer of the standard BiCMOS/CMOS process, therefore, evading any further need of cumbersome post processing of the fabricated sensor chip. The sensor is based on capacitive detection of the amount of non-creatinine bound antibodies binding to an immobilized creatinine layer on the passivated sensor. The chip bound antibody amount in turn corresponds indirectly to the creatinine concentration used in the incubation phase. The determination of creatinine in the concentration range of 0.88-880 μM is successfully demonstrated in this work. A sensitivity of 35 MHz/10 fold increase in creatinine concentration (during incubation) at the centre frequency of 6 GHz is gained by the immunosensor. The results are compared with a standard optical measurement technique and the dynamic range and sensitivity is of the order of the established optical indication technique. The C-band immunosensor chip comprising an area of 0.3 mm(2) reduces the sensing area considerably, therefore, requiring a sample volume as low as 2 μl. The small analyte sample volume and label free approach also reduce the experimental costs in addition to the low fabrication costs offered by the batch fabrication technique of CMOS/BiCMOS process.
Collapse
Affiliation(s)
- S Guha
- IHP, Im Technologie Park 25, 15236, Frankfurt (Oder), Germany.
| | | | | | | | | | | |
Collapse
|
54
|
Relative efficiency of zinc sulfide (ZnS) quantum dots (QDs) based electrochemical and fluorescence immunoassay for the detection of Staphylococcal enterotoxin B (SEB). ACTA ACUST UNITED AC 2015. [PMID: 28626706 PMCID: PMC5466261 DOI: 10.1016/j.btre.2015.02.004] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
In this paper an attempt was made to detect Staphylococcal enterotoxin B (SEB) both by electrochemical and fluorescence immunoassay methods using zinc sulphide (ZnS) QDs. Wet-chemical method was adopted for the preparation of fluorescent ZnS QDs (diameter ∼ 5–10 nm). These QDs were bioconjugated with monoclonal antibodies and then characterized by various method. A detection limit of 0.02 ng mL−1 by fluorescence assay and 1.0 ng mL−1 by electrochemical assay for SEB was achieved. While by sandwich ELISA it is possible to detect 0.24 ng mL−1 only. The sensitivity of all techniques is very good, since the LD50 of SEB is 20 ng kg−1. Electrochemical assay is faster, need low-cost instrument, independent to the size of QDs and found to be one of the best alternative methods as compared to the other existing methods studied herein. The presented method could be expanded to the development of electrochemical and fluorescence biosensors for various agents for field and laboratory use.
Collapse
|
55
|
Abstract
Flow cytometry is used for cell counting and analysis in numerous clinical and environmental applications. However flow cytometry is not used in mHealth mainly because current flow cytometers are large, expensive, power-intensive devices designed to operate in a laboratory. Their design results in a lack of portability and makes them unsuitable for mHealth applications. Another limitation of current technology is the low volumetric throughput rates that are not suitable for rapid detection of rare cells.To address these limitations, we describe here a novel, low-cost, mobile flow cytometer based on wide-field imaging with a webcam for large volume and high throughput fluorescence detection of rare cells as a simulation for circulating tumor cells (CTCs) detection. The mobile flow cytometer uses a commercially available webcam capable of 187 frames per second video capture at a resolution of 320 × 240 pixels. For fluorescence detection, a 1 W 450 nm blue laser is used for excitation of Syto-9 fluorescently stained cells detected at 535 nm. A wide-field flow cell was developed for large volume analysis that allows for the linear velocity of target cells to be lower than in conventional hydrodynamic focusing flow cells typically used in cytometry. The mobile flow cytometer was found to be capable of detecting low concentrations at flow rates of 500 μL/min, suitable for rare cell detection in large volumes. The simplicity and low cost of this device suggests that it may have a potential clinical use for mHealth flow cytometry for resource-poor settings associated with global health.
Collapse
Affiliation(s)
- Joshua Balsam
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD, 20993, USA
| | | | | |
Collapse
|
56
|
Chang CW, Peng CC, Liao WH, Tung YC. Polydimethylsiloxane SlipChip for mammalian cell culture applications. Analyst 2015; 140:7355-65. [DOI: 10.1039/c5an00547g] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
A polydimethylsiloxane (PDMS) SlipChip for in vitro mammalian cell culture applications, including multiple-treatment assays, cell co-culture, and cytokine detection assays.
Collapse
Affiliation(s)
- Chia-Wen Chang
- Research Center for Applied Sciences
- Academia Sinica
- Taipei 11529
- Taiwan
| | - Chien-Chung Peng
- Research Center for Applied Sciences
- Academia Sinica
- Taipei 11529
- Taiwan
| | - Wei-Hao Liao
- Research Center for Applied Sciences
- Academia Sinica
- Taipei 11529
- Taiwan
| | - Yi-Chung Tung
- Research Center for Applied Sciences
- Academia Sinica
- Taipei 11529
- Taiwan
| |
Collapse
|
57
|
Li L, Xia LR, Wang HY, Bi XD. New method for fabricating an α-fetoprotein affinity monolithic polymer array. J Appl Polym Sci 2014. [DOI: 10.1002/app.41792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Li Li
- Institute of Facilities and Equipment in Agriculture; Jiangsu Academy of Agricultural Sciences; Nanjing 210014 China
| | - Li-Ru Xia
- Institute of Facilities and Equipment in Agriculture; Jiangsu Academy of Agricultural Sciences; Nanjing 210014 China
| | - He-Ye Wang
- Institute of Facilities and Equipment in Agriculture; Jiangsu Academy of Agricultural Sciences; Nanjing 210014 China
| | - Xiao-Dong Bi
- Key Laboratory of Analytical Chemistry for Life Science; School of Chemistry and Chemical Engineering; Nanjing University; Nanjing 210093 China
| |
Collapse
|
58
|
Chen A, Wang R, Bever CRS, Xing S, Hammock BD, Pan T. Smartphone-interfaced lab-on-a-chip devices for field-deployable enzyme-linked immunosorbent assay. BIOMICROFLUIDICS 2014; 8:064101. [PMID: 25553178 PMCID: PMC4241779 DOI: 10.1063/1.4901348] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2014] [Accepted: 10/30/2014] [Indexed: 05/09/2023]
Abstract
The emerging technologies on mobile-based diagnosis and bioanalytical detection have enabled powerful laboratory assays such as enzyme-linked immunosorbent assay (ELISA) to be conducted in field-use lab-on-a-chip devices. In this paper, we present a low-cost universal serial bus (USB)-interfaced mobile platform to perform microfluidic ELISA operations in detecting the presence and concentrations of BDE-47 (2,2',4,4'-tetrabromodiphenyl ether), an environmental contaminant found in our food supply with adverse health impact. Our point-of-care diagnostic device utilizes flexible interdigitated carbon black electrodes to convert electric current into a microfluidic pump via gas bubble expansion during electrolytic reaction. The micropump receives power from a mobile phone and transports BDE-47 analytes through the microfluidic device conducting competitive ELISA. Using variable domain of heavy chain antibodies (commonly referred to as single domain antibodies or Nanobodies), the proposed device is sensitive for a BDE-47 concentration range of 10(-3)-10(4 ) μg/l, with a comparable performance to that uses a standard competitive ELISA protocol. It is anticipated that the potential impact in mobile detection of health and environmental contaminants will prove beneficial to our community and low-resource environments.
Collapse
Affiliation(s)
- Arnold Chen
- Department of Biomedical Engineering, University of California , Davis, California 95616, USA
| | - Royal Wang
- Department of Biomedical Engineering, University of California , Davis, California 95616, USA
| | - Candace R S Bever
- Department of Entomology and Nematology, University of California , Davis, California 95616, USA
| | - Siyuan Xing
- Department of Biomedical Engineering, University of California , Davis, California 95616, USA
| | | | - Tingrui Pan
- Department of Biomedical Engineering, University of California , Davis, California 95616, USA
| |
Collapse
|
59
|
Coskun AF, Cetin AE, Galarreta BC, Alvarez DA, Altug H, Ozcan A. Lensfree optofluidic plasmonic sensor for real-time and label-free monitoring of molecular binding events over a wide field-of-view. Sci Rep 2014; 4:6789. [PMID: 25346102 DOI: 10.1038/lsa.2014.3] [Citation(s) in RCA: 159] [Impact Index Per Article: 15.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2014] [Revised: 08/21/2013] [Accepted: 10/06/2014] [Indexed: 05/28/2023] Open
Abstract
We demonstrate a high-throughput biosensing device that utilizes microfluidics based plasmonic microarrays incorporated with dual-color on-chip imaging toward real-time and label-free monitoring of biomolecular interactions over a wide field-of-view of >20 mm(2). Weighing 40 grams with 8.8 cm in height, this biosensor utilizes an opto-electronic imager chip to record the diffraction patterns of plasmonic nanoapertures embedded within microfluidic channels, enabling real-time analyte exchange. This plasmonic chip is simultaneously illuminated by two different light-emitting-diodes that are spectrally located at the right and left sides of the plasmonic resonance mode, yielding two different diffraction patterns for each nanoaperture array. Refractive index changes of the medium surrounding the near-field of the nanostructures, e.g., due to molecular binding events, induce a frequency shift in the plasmonic modes of the nanoaperture array, causing a signal enhancement in one of the diffraction patterns while suppressing the other. Based on ratiometric analysis of these diffraction images acquired at the detector-array, we demonstrate the proof-of-concept of this biosensor by monitoring in real-time biomolecular interactions of protein A/G with immunoglobulin G (IgG) antibody. For high-throughput on-chip fabrication of these biosensors, we also introduce a deep ultra-violet lithography technique to simultaneously pattern thousands of plasmonic arrays in a cost-effective manner.
Collapse
Affiliation(s)
- Ahmet F Coskun
- 1] Departments of Electrical Engineering and Bioengineering, University of California, Los Angeles (UCLA), CA 90095, USA [2] Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA, 91125
| | - Arif E Cetin
- 1] Department of Electrical and Computer Engineering, Boston University, MA 02215, USA [2] Bioengineering Department, Ecole Polytechnique Federale de Lausanne (EPFL), Lausanne CH-1015 Switzerland
| | - Betty C Galarreta
- 1] Department of Electrical and Computer Engineering, Boston University, MA 02215, USA [2] Pontificia Universidad Catolica del Peru, Departamento de Ciencias-Quimica, Avenida Universitaria 1801, Lima 32, Peru
| | | | - Hatice Altug
- 1] Department of Electrical and Computer Engineering, Boston University, MA 02215, USA [2] Bioengineering Department, Ecole Polytechnique Federale de Lausanne (EPFL), Lausanne CH-1015 Switzerland
| | - Aydogan Ozcan
- 1] Departments of Electrical Engineering and Bioengineering, University of California, Los Angeles (UCLA), CA 90095, USA [2] California NanoSystems Institute, University of California, Los Angeles (UCLA), CA 90095, USA
| |
Collapse
|
60
|
Ortega M, Hanrahan G, Arceo M, Gomez FA. Application of a computational neural network to optimize the fluorescence signal from a receptor-ligand interaction on a microfluidic chip. Electrophoresis 2014; 36:393-7. [DOI: 10.1002/elps.201400288] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2014] [Revised: 07/29/2014] [Accepted: 07/30/2014] [Indexed: 12/16/2022]
Affiliation(s)
- Maria Ortega
- Department of Chemistry and Biochemistry; California State University; Los Angeles CA USA
| | - Grady Hanrahan
- Department of Chemistry; California Lutheran University; Thousand Oaks CA USA
- Hugh and Hazel Darling Center for Applied Scientific Computing; California Lutheran University; Thousand Oaks CA USA
| | - Marilyn Arceo
- Department of Chemistry; California Lutheran University; Thousand Oaks CA USA
| | - Frank A. Gomez
- Department of Chemistry and Biochemistry; California State University; Los Angeles CA USA
| |
Collapse
|
61
|
Sharma A, Rao VK, Kamboj DV, Upadhyay S, Shaik M, Shrivastava AR, Jain R. Sensitive detection of staphylococcal enterotoxin B (SEB) using quantum dots by various methods with special emphasis on an electrochemical immunoassay approach. RSC Adv 2014. [DOI: 10.1039/c4ra02563f] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
62
|
Sharma A, Kameswara Rao V, Vrat Kamboj D, Jain R. Electrochemical Immunosensor for Staphylococcal Enterotoxin B (SEB) Based on Platinum Nanoparticles-Modified Electrode Using Hydrogen Evolution Inhibition Approach. ELECTROANAL 2014. [DOI: 10.1002/elan.201400100] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
63
|
Tokel O, Inci F, Demirci U. Advances in plasmonic technologies for point of care applications. Chem Rev 2014; 114:5728-52. [PMID: 24745365 PMCID: PMC4086846 DOI: 10.1021/cr4000623] [Citation(s) in RCA: 224] [Impact Index Per Article: 22.4] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2013] [Indexed: 12/12/2022]
Affiliation(s)
- Onur Tokel
- Demirci
Bio-Acoustic-MEMS in Medicine (BAMM) Laboratory, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical
School, Cambridge, Massachusetts 02139, United States
| | - Fatih Inci
- Demirci
Bio-Acoustic-MEMS in Medicine (BAMM) Laboratory, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical
School, Cambridge, Massachusetts 02139, United States
- Demirci
Bio-Acoustic-MEMS in Medicine (BAMM) Laboratory, Stanford University School of Medicine, Canary Center at Stanford
for Cancer Early Detection, Palo
Alto, California 94304, United States
| | - Utkan Demirci
- Demirci
Bio-Acoustic-MEMS in Medicine (BAMM) Laboratory, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical
School, Cambridge, Massachusetts 02139, United States
- Division of Infectious Diseases, Brigham
and Women’s Hospital, Harvard Medical
School, Boston, Massachusetts 02115, United States
- Harvard-MIT
Health Sciences and Technology, Cambridge, Massachusetts 02139, United States
- Demirci
Bio-Acoustic-MEMS in Medicine (BAMM) Laboratory, Stanford University School of Medicine, Canary Center at Stanford
for Cancer Early Detection, Palo
Alto, California 94304, United States
| |
Collapse
|
64
|
Balsam J, Rasooly R, Bruck HA, Rasooly A. Thousand-fold fluorescent signal amplification for mHealth diagnostics. Biosens Bioelectron 2014; 51:1-7. [PMID: 23928092 PMCID: PMC3795847 DOI: 10.1016/j.bios.2013.06.053] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2013] [Revised: 06/19/2013] [Accepted: 06/26/2013] [Indexed: 01/27/2023]
Abstract
The low sensitivity of Mobile Health (mHealth) optical detectors, such as those found on mobile phones, is a limiting factor for many mHealth clinical applications. To improve sensitivity, we have combined two approaches for optical signal amplification: (1) a computational approach based on an image stacking algorithm to decrease the image noise and enhance weak signals, and (2) an optical signal amplifier utilizing a capillary tube array. These approaches were used in a detection system which includes multi-wavelength LEDs capable of exciting many fluorophores in multiple wavelengths, a mobile phone or a webcam as a detector, and capillary tube array configured with 36 capillary tubes for signal enhancement. The capillary array enables a ~100× increase in signal sensitivity for fluorescein, reducing the limit of detection (LOD) for mobile phones and webcams from 1000 nM to 10nM. Computational image stacking enables another ~10× increase in signal sensitivity, further reducing the LOD for webcam from 10nM to 1 nM. To demonstrate the feasibility of the device for the detection of disease-related biomarkers, adenovirus DNA labeled with SYBR green or fluorescein was analyzed by both our capillary array and a commercial plate reader. The LOD for the capillary array was 5 ug/mL, and that of the plate reader was 1 ug/mL. Similar results were obtained using DNA stained with fluorescein. The combination of the two signal amplification approaches enables a ~1000× increase in LOD for the webcam platform. This brings it into the range of a conventional plate reader while using a smaller sample volume (10 ul) than the plate reader requires (100 ul). This suggests that such a device could be suitable for biosensing applications where up to 10 fold smaller sample sizes are needed. The simple optical configuration for mHealth described in this paper employing the combined capillary and image processing signal amplification is capable of measuring weak fluorescent signals without the need of dedicated laboratories. It has the potential to be used to increase sensitivity of other optically based mHealth technologies, and may increase mHealth's clinical utility, especially for telemedicine and for resource-poor settings and global health applications.
Collapse
Affiliation(s)
- Joshua Balsam
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993, United States; University of Maryland, College Park, MD 20742, United States
| | | | | | | |
Collapse
|
65
|
Song P, Hu R, Tng DJH, Yong KT. Moving towards individualized medicine with microfluidics technology. RSC Adv 2014. [DOI: 10.1039/c3ra45629c] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
|
66
|
Jung W, Han J, Kai J, Lim JY, Sul D, Ahn CH. An innovative sample-to-answer polymer lab-on-a-chip with on-chip reservoirs for the POCT of thyroid stimulating hormone (TSH). LAB ON A CHIP 2013; 13:4653-62. [PMID: 24121997 DOI: 10.1039/c3lc50403d] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
A new sample-to-answer polymer lab-on-a-chip, which can perform immunoassay with minimum user intervention through on-chip reservoirs for reagents and single-channel assay system, has been designed, developed and successfully characterized as a point-of-care testing (POCT) cartridge for the detection of thyroid stimulating hormone (TSH). Test results were obtained within 30 minutes after a sample was dropped into the POCT cartridge. The analyzed results of TSH showed a linear range of up to 55 μIU mL(-1) with the limit of detection (LOD) of 1.9 μIU mL(-1) at the signal-to-noise ratio (SNR) of 3. The reagents stored in the on-chip reservoirs maintained more than 97% of their initial volume for 120 days of storage time while the detection antibody retained its activity above 98% for 120 days. The sample-to-answer polymer lab-on-a-chip developed in this work using the mass-producible and low-cost polymer is well suited for the point-of-care testing of rapid in vitro diagnostics (IVD) of TSH.
Collapse
Affiliation(s)
- Wooseok Jung
- Microsystems and BioMEMS Laboratory, University of Cincinnati, Cincinnati, OH 45221, USA.
| | | | | | | | | | | |
Collapse
|
67
|
Navruz I, Coskun AF, Wong J, Mohammad S, Tseng D, Nagi R, Phillips S, Ozcan A. Smart-phone based computational microscopy using multi-frame contact imaging on a fiber-optic array. LAB ON A CHIP 2013; 13:4015-23. [PMID: 23939637 PMCID: PMC3804724 DOI: 10.1039/c3lc50589h] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
We demonstrate a cellphone based contact microscopy platform, termed Contact Scope, which can image highly dense or connected samples in transmission mode. Weighing approximately 76 grams, this portable and compact microscope is installed on the existing camera unit of a cellphone using an opto-mechanical add-on, where planar samples of interest are placed in contact with the top facet of a tapered fiber-optic array. This glass-based tapered fiber array has ~9 fold higher density of fiber optic cables on its top facet compared to the bottom one and is illuminated by an incoherent light source, e.g., a simple light-emitting-diode (LED). The transmitted light pattern through the object is then sampled by this array of fiber optic cables, delivering a transmission image of the sample onto the other side of the taper, with ~3× magnification in each direction. This magnified image of the object, located at the bottom facet of the fiber array, is then projected onto the CMOS image sensor of the cellphone using two lenses. While keeping the sample and the cellphone camera at a fixed position, the fiber-optic array is then manually rotated with discrete angular increments of e.g., 1-2 degrees. At each angular position of the fiber-optic array, contact images are captured using the cellphone camera, creating a sequence of transmission images for the same sample. These multi-frame images are digitally fused together based on a shift-and-add algorithm through a custom-developed Android application running on the smart-phone, providing the final microscopic image of the sample, visualized through the screen of the phone. This final computation step improves the resolution and also removes spatial artefacts that arise due to non-uniform sampling of the transmission intensity at the fiber optic array surface. We validated the performance of this cellphone based Contact Scope by imaging resolution test charts and blood smears.
Collapse
Affiliation(s)
- Isa Navruz
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA.
| | | | | | | | | | | | | | | |
Collapse
|
68
|
Bruck HA, Yang M, Kostov Y, Rasooly A. Electrical percolation based biosensors. Methods 2013; 63:282-9. [PMID: 24041756 PMCID: PMC3902888 DOI: 10.1016/j.ymeth.2013.08.031] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2013] [Revised: 07/30/2013] [Accepted: 08/28/2013] [Indexed: 01/29/2023] Open
Abstract
A new approach to label free biosensing has been developed based on the principle of "electrical percolation". In electrical percolation, long-range electrical connectivity is formed in randomly oriented and distributed systems of discrete elements. By applying this principle to biological interactions, it is possible to measure biological components both directly and electronically. The main element for electrical percolation biosensor is the biological semiconductor (BSC) which is a multi-layer 3-D carbon nanotube-antibody network. In the BSC, molecular interactions, such as binding of antigens to the antibodies, disrupt the network continuity causing increased resistance of the network. BSCs can be fabricated by immobilizing conducting elements, such as pre-functionalized single-walled carbon nanotubes (SWNTs)-antibody complex, directly onto a substrate, such as a Poly(methyl methacrylate) (PMMA) surface (also known as plexi-glass or Acrylic). BSCs have been demonstrated for direct (label-free) electronic measurements of antibody-antigen binding using SWNTs. If the concentration of the SWNT network is slightly above the electrical percolation threshold, then binding of a specific antigen to the pre-functionalized SWNT dramatically increases the electrical resistance due to changes in the tunneling between the SWNTs. Using anti-staphylococcal enterotoxin B (SEB) IgG as a "gate" and SEB as an "actuator", it was demonstrated that the BSC was able to detect SEB at concentrations of 1 ng/ml. Based on this concept, an automated configuration for BSCs is described here that enables real time continuous detection. The new BSC configuration may permit assembly of multiple sensors on the same chip to create "biological central processing units (CPUs)" with multiple biological elements, capable of processing and sorting out information on multiple analytes simultaneously.
Collapse
Affiliation(s)
- Hugh Alan Bruck
- University of Maryland College Park (UMCP), College Park MD 20742
| | - Minghui Yang
- College of Chemistry and Chemical Engineering, Central South University, Changsha, China, 410083, China
| | | | - Avraham Rasooly
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993
- National Cancer Institute, Rockville, MD 20850
| |
Collapse
|
69
|
Balsam J, Bruck HA, Rasooly A. Capillary Array Waveguide Amplified Fluorescence Detector for mHealth. SENSORS AND ACTUATORS. B, CHEMICAL 2013; 186:711-717. [PMID: 24039345 PMCID: PMC3769705 DOI: 10.1016/j.snb.2013.06.030] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Mobile Health (mHealth) analytical technologies are potentially useful for carrying out modern medical diagnostics in resource-poor settings. Effective mHealth devices for underserved populations need to be simple, low cost, and portable. Although cell phone cameras have been used for biodetection, their sensitivity is a limiting factor because currently it is too low to be effective for many mHealth applications, which depend on detection of weak fluorescent signals. To improve the sensitivity of portable phones, a capillary tube array was developed to amplify fluorescence signals using their waveguide properties. An array configured with 36 capillary tubes was demonstrated to have a ~100X increase in sensitivity, lowering the limit of detection (LOD) of mobile phones from 1000 nM to 10 nM for fluorescein. To confirm that the amplification was due to waveguide behavior, we coated the external surfaces of the capillaries with silver. The silver coating interfered with the waveguide behavior and diminished the fluorescence signal, thereby proving that the waveguide behavior was the main mechanism for enhancing optical sensitivity. The optical configuration described here is novel in several ways. First, the use of capillaries waveguide properties to improve detection of weak florescence signal is new. Second we describe here a three dimensional illumination system, while conventional angular laser waveguide illumination is spot (or line), which is functionally one-dimensional illumination, can illuminate only a single capillary or a single column (when a line generator is used) of capillaries and thus inherently limits the multiplexing capability of detection. The planar illumination demonstrated in this work enables illumination of a two dimensional capillary array (e.g. x columns and y rows of capillaries). In addition, the waveguide light propagation via the capillary wall provides a third dimension for illumination along the axis of the capillaries. Such an array can potentially be used for sensitive analysis of multiple fluorescent detection assays simultaneously. The simple phone based capillary array approach presented in this paper is capable of amplifying weak fluorescent signals thereby improving the sensitivity of optical detectors based on mobile phones. This may allow sensitive biological assays to be measured with low sensitivity detectors and may make mHealth practical for many diagnostics applications, especially in resource-poor and global health settings.
Collapse
Affiliation(s)
- Joshua Balsam
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993 ; University of Maryland, College Park, MD 20742
| | | | | |
Collapse
|
70
|
Hu W, Lu Z, Liu Y, Chen T, Zhou X, Li CM. A portable flow-through fluorescent immunoassay lab-on-a-chip device using ZnO nanorod-decorated glass capillaries. LAB ON A CHIP 2013; 13:1797-1802. [PMID: 23483058 DOI: 10.1039/c3lc41382a] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We report a portable flow-through fluorescent immunoassay lab-on-a-chip device using inexpensive disposable glass capillaries for medical diagnostics. The device is made up of a number of serially connected glass capillaries, of which each interior surface is grown using zinc oxide (ZnO) nanorods, which different probe antibodies are attached to. The ZnO nanorods not only provide a large surface area for high density probe attachment, but also enhance the fluorescent signals to significantly improve the detection signal responses. The glass capillary also allows for convenient flow-through detection. Coupled with a homemade handheld analyzer integrated with an automatic pump system and a fluorescence readout module, a portable immunoassay capillary device enables quantitative detection of multiple biomarkers in 30 min with detection limits of 1-5 ng mL(-1) and wide dynamic ranges for prostate specific antigen (PSA), α-Fetoprotein (AFP) and carcinoembryonic antigen (CEA) in serum. This new conceptual lab-on-a-chip device eliminates the need for expensive micro-fabrication processes, while offering inexpensive and disposable, but replaceable tube-type "microchannels" for multiplexed detection in portable clinical diagnostics.
Collapse
Affiliation(s)
- Weihua Hu
- Institute of Clean Energy & Advanced Materials, Southwest University, Chongqing, P R China
| | | | | | | | | | | |
Collapse
|
71
|
Balsam J, Ossandon M, Bruck HA, Lubensky I, Rasooly A. Low-cost technologies for medical diagnostics in low-resource settings. ACTA ACUST UNITED AC 2013; 7:243-55. [DOI: 10.1517/17530059.2013.767796] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
72
|
Zhu H, Isikman SO, Mudanyali O, Greenbaum A, Ozcan A. Optical imaging techniques for point-of-care diagnostics. LAB ON A CHIP 2013; 13:51-67. [PMID: 23044793 PMCID: PMC3510351 DOI: 10.1039/c2lc40864c] [Citation(s) in RCA: 198] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Improving access to effective and affordable healthcare has long been a global endeavor. In this quest, the development of cost-effective and easy-to-use medical testing equipment that enables rapid and accurate diagnosis is essential to reduce the time and costs associated with healthcare services. To this end, point-of-care (POC) diagnostics plays a crucial role in healthcare delivery in both developed and developing countries by bringing medical testing to patients, or to sites near patients. As the diagnosis of a wide range of diseases, including various types of cancers and many endemics, relies on optical techniques, numerous compact and cost-effective optical imaging platforms have been developed in recent years for use at the POC. Here, we review the state-of-the-art optical imaging techniques that can have a significant impact on global health by facilitating effective and affordable POC diagnostics.
Collapse
Affiliation(s)
- Hongying Zhu
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA
| | - Serhan O. Isikman
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA
| | - Onur Mudanyali
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA
| | - Alon Greenbaum
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA
| | - Aydogan Ozcan
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA
- Bioengineering Department, University of California, Los Angeles, CA, 90095, USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095, USA
| |
Collapse
|
73
|
Abstract
Laminated object manufacturing (LOM) technology using polymer sheets is an easy and affordable method for rapid prototyping of Lab-on-a-Chip (LOC) systems. It has recently been used to fabricate a miniature 96 sample ELISA lab-on-a-chip (ELISA-LOC) by integrating the washing step directly into an ELISA plate. LOM has been shown to be capable of creating complex 3D microfluidics through the assembly of a stack of polymer sheets with features generated by laser micromachining and by bonding the sheets together with adhesive. A six layer ELISA-LOC was fabricated with an acrylic (poly(methyl methacrylate) (PMMA)) core and five polycarbonate layers micromachined by a CO(2) laser with simple microfluidic features including a miniature 96-well sample plate. Immunological assays can be carried out in several configurations (1 × 96 wells, 2 × 48 wells, or 4 × 24 wells). The system includes three main functional elements: (1) a reagent loading fluidics module, (2) an assay and detection wells plate, and (3) a reagent removal fluidics module. The ELISA-LOC system combines several biosensing elements: (1) carbon nanotube (CNT) technology to enhance primary antibody immobilization, (2) sensitive ECL (electrochemiluminescence) detection, and (3) a charge-coupled device (CCD) detector for measuring the light signal generated by ECL. Using a sandwich ELISA assay, the system detected Staphylococcal enterotoxin B (SEB) at concentrations as low as 0.1 ng/ml, a detection level similar to that reported for conventional ELISA. ELISA-LOC can be operated by a syringe and does not require power for operation. This simple point-of-care (POC) system is useful for carrying out various immunological assays and other complex medical assays without the laboratory required for conventional ELISA, and therefore may be more useful for global healthcare delivery.
Collapse
Affiliation(s)
- Avraham Rasooly
- Division of Biology, Office of Science and Engineering, FDA Center for Devices and Radiological Health (CDRH), Silver Spring, MD, USA.
| | | | | |
Collapse
|
74
|
Oliveira KA, Rodrigues de Oliveira C, Antonelli da Silveira L, Tomazelli Coltro WK. Laser-printing of toner-based 96-microzone plates for immunoassays. Analyst 2013; 138:1114-21. [DOI: 10.1039/c2an36532d] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
75
|
Yoon JY, Kim B. Lab-on-a-chip pathogen sensors for food safety. SENSORS (BASEL, SWITZERLAND) 2012; 12:10713-41. [PMID: 23112625 PMCID: PMC3472853 DOI: 10.3390/s120810713] [Citation(s) in RCA: 87] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/09/2012] [Revised: 06/28/2012] [Accepted: 07/04/2012] [Indexed: 02/08/2023]
Abstract
There have been a number of cases of foodborne illness among humans that are caused by pathogens such as Escherichia coli O157:H7, Salmonella typhimurium, etc. The current practices to detect such pathogenic agents are cell culturing, immunoassays, or polymerase chain reactions (PCRs). These methods are essentially laboratory-based methods that are not at all real-time and thus unavailable for early-monitoring of such pathogens. They are also very difficult to implement in the field. Lab-on-a-chip biosensors, however, have a strong potential to be used in the field since they can be miniaturized and automated; they are also potentially fast and very sensitive. These lab-on-a-chip biosensors can detect pathogens in farms, packaging/processing facilities, delivery/distribution systems, and at the consumer level. There are still several issues to be resolved before applying these lab-on-a-chip sensors to field applications, including the pre-treatment of a sample, proper storage of reagents, full integration into a battery-powered system, and demonstration of very high sensitivity, which are addressed in this review article. Several different types of lab-on-a-chip biosensors, including immunoassay- and PCR-based, have been developed and tested for detecting foodborne pathogens. Their assay performance, including detection limit and assay time, are also summarized. Finally, the use of optical fibers or optical waveguide is discussed as a means to improve the portability and sensitivity of lab-on-a-chip pathogen sensors.
Collapse
Affiliation(s)
- Jeong-Yeol Yoon
- Department of Agricultural and Biosystems Engineering, the University of Arizona, Tucson, AZ 85721, USA.
| | | |
Collapse
|
76
|
Zhao X, Dong T, Yang Z, Pires N, Høivik N. Compatible immuno-NASBA LOC device for quantitative detection of waterborne pathogens: design and validation. LAB ON A CHIP 2012; 12:602-612. [PMID: 22146918 DOI: 10.1039/c1lc20836e] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Waterborne pathogens usually pose a global threat to animals and human beings. There has been a growing demand for convenient and sensitive tools to detect the potential emerging pathogens in water. In this study, a lab-on-a-chip (LOC) device based on the real-time immuno-NASBA (immuno-nucleic acid sequence-based amplification) assay was designed, fabricated and verified. The disposable immuno-NASBA chip is modelled on a 96-well ELISA microplate, which contains 43 reaction chambers inside the bionic channel networks. All valves are designed outside the chip and are reusable. The sample and reagent solutions were pushed into each chamber in turn, which was controlled by the valve system. Notably, the immuno-NASBA chip is completely compatible with common microplate readers in a biological laboratory, and can distinguish multiple waterborne pathogens in water samples quantitatively and simultaneously. The performance of the LOC device was demonstrated by detecting the presence of a synthetic peptide, ACTH (adrenocorticotropic hormone) and two common waterborne pathogens, Escherichia coli (E. coli) and rotavirus, in artificial samples. The results indicated that the LOC device has the potential to quantify traces of waterborne pathogens at femtomolar levels with high specificity, although the detection process was still subject to some factors, such as ribonuclease (RNase) contamination and non-specific adsorption. As an ultra-sensitive tool to quantify waterborne pathogens, the LOC device can be used to monitor water quality in the drinking water system. Furthermore, a series of compatible high-throughput LOC devices for monitoring waterborne pathogens could be derived from this prototype with the same design idea, which may render the complicated immuno-NASBA assays convenient to common users without special training.
Collapse
Affiliation(s)
- Xinyan Zhao
- Department of Micro and Nano Systems Technology, Faculty of Engineering and Marine Sciences, Vestfold University College, Tønsberg, Box 2243, N-3103, Norway
| | | | | | | | | |
Collapse
|
77
|
Kovarik ML, Gach PC, Ornoff DM, Wang Y, Balowski J, Farrag L, Allbritton NL. Micro total analysis systems for cell biology and biochemical assays. Anal Chem 2012; 84:516-40. [PMID: 21967743 PMCID: PMC3264799 DOI: 10.1021/ac202611x] [Citation(s) in RCA: 180] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Michelle L. Kovarik
- Department of Chemistry, University of North Carolina, Chapel Hill, North Carolina 27599
| | - Phillip C. Gach
- Department of Chemistry, University of North Carolina, Chapel Hill, North Carolina 27599
| | - Douglas M. Ornoff
- Department of Chemistry, University of North Carolina, Chapel Hill, North Carolina 27599
- Department of Pharmacology, University of North Carolina, Chapel Hill, North Carolina 27599
| | - Yuli Wang
- Department of Chemistry, University of North Carolina, Chapel Hill, North Carolina 27599
| | - Joseph Balowski
- Department of Chemistry, University of North Carolina, Chapel Hill, North Carolina 27599
| | - Lila Farrag
- School of Medicine, University of North Carolina, Chapel Hill, North Carolina 27599
| | - Nancy L. Allbritton
- Department of Chemistry, University of North Carolina, Chapel Hill, North Carolina 27599
- Department of Biomedical Engineering, University of North Carolina, Chapel Hill, NC 27599 and North Carolina State University, Raleigh, NC 27695
| |
Collapse
|
78
|
|
79
|
Balsam J, Ossandon M, Bruck HA, Rasooly A. Modeling and design of micromachined optical Söller collimators for lensless CCD-based fluorometry. Analyst 2012; 137:5011-7. [DOI: 10.1039/c2an35729a] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
80
|
Novo P, Prazeres DMF, Chu V, Conde JP. Microspot-based ELISA in microfluidics: chemiluminescence and colorimetry detection using integrated thin-film hydrogenated amorphous silicon photodiodes. LAB ON A CHIP 2011; 11:4063-71. [PMID: 22012414 DOI: 10.1039/c1lc20362b] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Microfluidic technology has the potential to decrease the time of analysis and the quantity of sample and reactants required in immunoassays, together with the potential of achieving high sensitivity, multiplexing, and portability. A lab-on-a-chip system was developed and optimized using optical and fluorescence microscopy. Primary antibodies are adsorbed onto the walls of a PDMS-based microchannel via microspotting. This probe antibody is then recognised using secondary FITC or HRP labelled antibodies responsible for providing fluorescence or chemiluminescent and colorimetric signals, respectively. The system incorporated a micron-sized thin-film hydrogenated amorphous silicon photodiode microfabricated on a glass substrate. The primary antibody spots in the PDMS-based microfluidic were precisely aligned with the photodiodes for the direct detection of the antibody-antigen molecular recognition reactions using chemiluminescence and colorimetry. The immunoassay takes ~30 min from assay to the integrated detection. The conditions for probe antibody microspotting and for the flow-through ELISA analysis in the microfluidic format with integrated detection were defined using antibody solutions with concentrations in the nM-μM range. Sequential colorimetric or chemiluminescence detection of specific antibody-antigen molecular recognition was quantitatively detected using the photodiode. Primary antibody surface densities down to 0.182 pmol cm(-2) were detected. Multiplex detection using different microspotted primary antibodies was demonstrated.
Collapse
Affiliation(s)
- Pedro Novo
- INESC Microsistemas e Nanotecnologias and IN-Institute of Nanoscience and Nanotechnology, Lisbon, Portugal
| | | | | | | |
Collapse
|
81
|
Zhang Y, Ren L, Tu Q, Wang X, Liu R, Li L, Wang JC, Liu W, Xu J, Wang J. Fabrication of Reversible Poly(dimethylsiloxane) Surfaces via Host–Guest Chemistry and Their Repeated Utilization in Cardiac Biomarker Analysis. Anal Chem 2011; 83:9651-9. [DOI: 10.1021/ac202517x] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Yanrong Zhang
- Colleges of Science and Veterinary Medicine, Northwest A&F University, Yangling, Shaanxi 712100, P. R. China
| | - Li Ren
- Colleges of Science and Veterinary Medicine, Northwest A&F University, Yangling, Shaanxi 712100, P. R. China
| | - Qin Tu
- Colleges of Science and Veterinary Medicine, Northwest A&F University, Yangling, Shaanxi 712100, P. R. China
| | - Xueqin Wang
- Colleges of Science and Veterinary Medicine, Northwest A&F University, Yangling, Shaanxi 712100, P. R. China
| | - Rui Liu
- Colleges of Science and Veterinary Medicine, Northwest A&F University, Yangling, Shaanxi 712100, P. R. China
| | - Li Li
- Colleges of Science and Veterinary Medicine, Northwest A&F University, Yangling, Shaanxi 712100, P. R. China
| | - Jian-Chun Wang
- Colleges of Science and Veterinary Medicine, Northwest A&F University, Yangling, Shaanxi 712100, P. R. China
| | - Wenming Liu
- Colleges of Science and Veterinary Medicine, Northwest A&F University, Yangling, Shaanxi 712100, P. R. China
| | - Juan Xu
- Colleges of Science and Veterinary Medicine, Northwest A&F University, Yangling, Shaanxi 712100, P. R. China
| | - Jinyi Wang
- Colleges of Science and Veterinary Medicine, Northwest A&F University, Yangling, Shaanxi 712100, P. R. China
- Shaanxi Key Laboratory of Molecular Biology for Agriculture, Northwest A&F University, Yangling, Shaanxi 712100, P. R. China
| |
Collapse
|
82
|
Yang M, Sun S, Kostov Y, Rasooly A. An automated point-of-care system for immunodetection of staphylococcal enterotoxin B. Anal Biochem 2011; 416:74-81. [PMID: 21640067 PMCID: PMC3148523 DOI: 10.1016/j.ab.2011.05.014] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2011] [Revised: 04/28/2011] [Accepted: 05/10/2011] [Indexed: 01/19/2023]
Abstract
An automated point-of-care (POC) immunodetection system for immunological detection of staphylococcal enterotoxin B (SEB) was designed, fabricated, and tested. The system combines several elements: (i) enzyme-linked immunosorbent assay-lab-on-a-chip (ELISA-LOC) with fluidics, (ii) a charge-coupled device (CCD) camera detector, (iii) pumps and valves for fluid delivery to the ELISA-LOC, (iv) a computer interface board, and (v) a computer for controlling the fluidics, logging, and data analysis of the CCD data. The ELISA-LOC integrates a simple microfluidic system into a miniature 96-well sample plate, allowing the user to carry out immunological assays without a laboratory. The analyte is measured in a sandwich ELISA assay format combined with a sensitive electrochemiluminescence (ECL) detection method. Using the POC system, SEB, a major foodborne toxin, was detected at concentrations as low as 0.1 ng/ml. This is similar to the reported sensitivity of conventional ELISA. The open platform with simple modular fluid delivery automation design described here is interchangeable between detection systems, and because of its versatility it can also be used to automate many other LOC systems, simplifying LOC development. This new POC system is useful for carrying out various immunological and other complex medical assays without a laboratory and can easily be adapted for high-throughput biological screening in remote and resource-poor areas.
Collapse
Affiliation(s)
- Minghui Yang
- Center for Advanced Sensor Technology, University of Maryland Baltimore County, MD 21250
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Steven Sun
- Center for Advanced Sensor Technology, University of Maryland Baltimore County, MD 21250
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993
| | - Yordan Kostov
- Center for Advanced Sensor Technology, University of Maryland Baltimore County, MD 21250
| | - Avraham Rasooly
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993
- National Cancer Institute, Bethesda, MD 20892
| |
Collapse
|
83
|
Highly sensitive poly[glycidyl methacrylate-co-poly(ethylene glycol) methacrylate] brush-based flow-through microarray immunoassay device. Biomed Microdevices 2011; 13:769-77. [DOI: 10.1007/s10544-011-9547-1] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
84
|
Yang M, Sun S, Kostov Y, Rasooly A. A simple 96 well microfluidic chip combined with visual and densitometry detection for resource-poor point of care testing. SENSORS AND ACTUATORS. B, CHEMICAL 2011; 153:176-181. [PMID: 21503269 PMCID: PMC3077757 DOI: 10.1016/j.snb.2010.10.027] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
There is a well-recognized need for low cost biodetection technologies for resource-poor settings with minimal medical infrastructure. Lab-on-a-chip (LOC) technology has the ability to perform biological assays in such settings. The aim of this work is to develop a low cost, high-throughput detection system for the analysis of 96 samples simultaneously outside the laboratory setting. To achieve this aim, several biosensing elements were combined: a syringe operated ELISA lab-on-a-chip (ELISA-LOC) which integrates fluid delivery system into a miniature 96-well plate; a simplified non-enzymatic reporter and detection approach using a gold nanoparticle-antibody conjugate as a secondary antibody and silver enhancement of the visual signal; and Carbon nanotubes (CNT) to increase primary antibody immobilization and improve assay sensitivity. Combined, these elements obviate the need for an ELISA washer, electrical power for operation and a sophisticated detector. We demonstrate the use of the device for detection of Staphylococcal enterotoxin B, a major foodborne toxin using three modes of detection, visual detection, CCD camera and document scanner. With visual detection or using a document scanner to measure the signal, the limit of detection (LOD) was 0.5ng/ml. In addition to visual detection, for precise quantitation of signal using densitometry and a CCD camera, the LOD was 0.1ng/ml for the CCD analysis and 0.5 ng/ml for the document scanner. The observed sensitivity is in the same range as laboratory-based ELISA testing. The point of care device can analyze 96 samples simultaneously, permitting high throughput diagnostics in the field and in resource poor areas without ready access to laboratory facilities or electricity.
Collapse
Affiliation(s)
- Minghui Yang
- Center for Advanced Sensor Technology, University of Maryland Baltimore County, MD 21250
| | | | | | | |
Collapse
|
85
|
Huang Y, Cai D, Chen P. Micro- and Nanotechnologies for Study of Cell Secretion. Anal Chem 2011; 83:4393-406. [DOI: 10.1021/ac200358b] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Affiliation(s)
- Yinxi Huang
- Division of Bioengineering, School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore 637457
| | - Dong Cai
- Biology Department, Boston College, Boston, Massachusetts 02467, United States
| | - Peng Chen
- Division of Bioengineering, School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore 637457
| |
Collapse
|
86
|
Balsam J, Ossandon M, Kostov Y, Bruck HA, Rasooly A. Lensless CCD-based fluorometer using a micromachined optical Söller collimator. LAB ON A CHIP 2011; 11:941-9. [PMID: 21243150 DOI: 10.1039/c0lc00431f] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
In this paper, we describe a simple charge-coupled device (CCD) based lensless fluorometer with sensitivity in the range of current ELISA plate readers. In our lensfree fluorometer, a multi-wavelength LED light source was used for fluorophore excitation. To collimate the light, we developed a simple optical Söller collimator based on a "stack of pinholes" (a stack of black PMMA with array of pinholes machined with laser) enabling the light to be collimated from the LED through the filters and the assay's microfluidics directly onto the CCD without a lens. The elimination of the lens that is used in almost all other current CCD based detection systems has four major advantages: (1) It simplifies the device design and fabrication while reducing cost. (2) It reduces the distance between the sample and the measuring device (without a lens the distance needed to focus the image on the CCD is reduced and the fluorometer can be more compact). (3) It couples the CCD and the detected surface by using an optical Söller Collimator which allows the use of filters for fluorescence detection. (4) It also uncouples the CCD and the microfluidics to enable the use of interchangeable fluidics while protecting the delicate CCD. The lensless CCD-based fluorometer is capable of detecting 16 samples simultaneously, and was used for in vitro detection of botulinum neurotoxin serotype A (BoNT-A) activity with a FRET assay that measures cleavage of a fluorophore-tagged peptide substrate specific for BoNT-A (SNAP-25) by the toxin light chain (LcA). The limit of detection (LOD) of our lensless fluorometer is 1.25 nM, which is similar to the LOD of a modern ELISA plate reader. Combined with microfluidics, this simple low cost point-of-care (POC) medical diagnostic system may be useful for the performance of many other complex medical diagnostic assays without a laboratory and thus potentially enhancing the accessibility and the quality of health care delivery in underserved populations.
Collapse
Affiliation(s)
- Joshua Balsam
- University of Maryland College Park (UMCP), College Park, MD 20742, USA
| | | | | | | | | |
Collapse
|
87
|
Pereira AT, Novo P, Prazeres DMF, Chu V, Conde JP. Heterogeneous immunoassays in microfluidic format using fluorescence detection with integrated amorphous silicon photodiodes. BIOMICROFLUIDICS 2011; 5:14102. [PMID: 21403847 PMCID: PMC3055902 DOI: 10.1063/1.3553014] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2010] [Accepted: 01/07/2011] [Indexed: 05/09/2023]
Abstract
Miniaturization of immunoassays through microfluidic technology has the potential to decrease the time and the quantity of reactants required for analysis, together with the potential of achieving multiplexing and portability. A lab-on-chip system incorporating a thin-film amorphous silicon (a-Si:H) photodiode microfabricated on a glass substrate with a thin-film amorphous silicon-carbon alloy directly deposited above the photodiode and acting as a fluorescence filter is integrated with a polydimethylsiloxane-based microfluidic network for the direct detection of antibody-antigen molecular recognition reactions using fluorescence. The model immunoassay used consists of primary antibody adsorption to the microchannel walls followed by its recognition by a secondary antibody labeled with a fluorescent quantum-dot tag. The conditions for the flow-through analysis in the microfluidic format were defined and the total assay time was 30 min. Specific molecular recognition was quantitatively detected. The measurements made with the a-Si:H photodiode are consistent with that obtained with a fluorescence microscope and both show a linear dependence on the antibody concentration in the nanomolar-micromolar range.
Collapse
|
88
|
Liu K, Fan ZH. Thermoplastic microfluidic devices and their applications in protein and DNA analysis. Analyst 2011; 136:1288-97. [PMID: 21274478 DOI: 10.1039/c0an00969e] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Microfluidics is a platform technology that has been used for genomics, proteomics, chemical synthesis, environment monitoring, cellular studies, and other applications. The fabrication materials of microfluidic devices have traditionally included silicon and glass, but plastics have gained increasing attention in the past few years. We focus this review on thermoplastic microfluidic devices and their applications in protein and DNA analysis. We outline the device design and fabrication methods, followed by discussion on the strategies of surface treatment. We then concentrate on several significant advancements in applying thermoplastic microfluidic devices to protein separation, immunoassays, and DNA analysis. Comparison among numerous efforts, as well as the discussion on the challenges and innovation associated with detection, is presented.
Collapse
Affiliation(s)
- Ke Liu
- Interdisciplinary Microsystems Group, Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, Florida 32611-6250, USA
| | | |
Collapse
|