Zaidi H, Alavi A, Naqa IE. Novel Quantitative PET Techniques for Clinical Decision Support in Oncology. Semin Nucl Med 2018; 48:548-564. [PMID: 30322481 DOI: 10.1053/j.semnuclmed.2018.07.003] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Quantitative image analysis has deep roots in the usage of positron emission tomography (PET) in clinical and research settings to address a wide variety of diseases. It has been extensively employed to assess molecular and physiological biomarkers in vivo in healthy and disease states, in oncology, cardiology, neurology, and psychiatry. Quantitative PET allows relating the time-varying activity concentration in tissues/organs of interest and the basic functional parameters governing the biological processes being studied. Yet, quantitative PET is challenged by a number of degrading physical factors related to the physics of PET imaging, the limitations of the instrumentation used, and the physiological status of the patient. Moreover, there is no consensus on the most reliable and robust image-derived PET metric(s) that can be used with confidence in clinical oncology owing to the discrepancies between the conclusions reported in the literature. There is also increasing interest in the use of artificial intelligence based techniques, particularly machine learning and deep learning techniques in a variety of applications to extract quantitative features (radiomics) from PET including image segmentation and outcome prediction in clinical oncology. These novel techniques are revolutionizing clinical practice and are now offering unique capabilities to the clinical molecular imaging community and biomedical researchers at large. In this report, we summarize recent developments and future tendencies in quantitative PET imaging and present example applications in clinical decision support to illustrate its potential in the context of clinical oncology.
Collapse
Affiliation(s)
- Habib Zaidi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland; Geneva Neuroscience Centre, University of Geneva, Geneva, Switzerland; Department of Nuclear Medicine and Molecular Imaging, University of Groningen, Groningen, the Netherlands; Department of Nuclear Medicine, University of Southern Denmark, Odense, Denmark.
| | - Abass Alavi
- Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA
| | - Issam El Naqa
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| |
Collapse
|
52
|
Zuo Y, Qi J, Wang G. Relative Patlak plot for dynamic PET parametric imaging without the need for early-time input function. Phys Med Biol 2018; 63:165004. [PMID: 30020080 DOI: 10.1088/1361-6560/aad444] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The Patlak graphical method is widely used in parametric imaging for modeling irreversible radiotracer kinetics in dynamic PET. The net influx rate of radiotracer can be determined from the slope of the Patlak plot. The implementation of the standard Patlak method requires the knowledge of full-time input function from the injection time until the scan end time, which presents a challenge for use in the clinic. This paper proposes a new relative Patlak plot method that does not require early-time input function and therefore can be more efficient for parametric imaging. Theoretical analysis proves that the effect of early-time input function is a constant scaling factor on the Patlak slope estimation. Thus, the parametric image of the slope of the relative Patlak plot is related to the parametric image of standard Patlak slope by a global scaling factor. This theoretical finding has been further demonstrated by computer simulation and real patient data. The study indicates that parametric imaging of the relative Patlak slope can be used as a substitute of parametric imaging of standard Patlak slope for tasks that do not require absolute quantification, such as lesion detection and tumor volume segmentation.
Collapse
Affiliation(s)
- Yang Zuo
- Department of Radiology, University of California at Davis, Sacramento, CA 95817, United States of America
| | | | | |
Collapse
|
53
|
Wang G, Corwin MT, Olson KA, Badawi RD, Sarkar S. Dynamic PET of human liver inflammation: impact of kinetic modeling with optimization-derived dual-blood input function. Phys Med Biol 2018; 63:155004. [PMID: 29847315 PMCID: PMC6105275 DOI: 10.1088/1361-6560/aac8cb] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
The hallmark of nonalcoholic steatohepatitis is hepatocellular inflammation and injury in the setting of hepatic steatosis. Recent work has indicated that dynamic 18F-FDG PET with kinetic modeling has the potential to assess hepatic inflammation noninvasively, while static FDG-PET is less promising. Because the liver has dual blood supplies, kinetic modeling of dynamic liver PET data is challenging in human studies. This paper aims to identify the optimal dual-input kinetic modeling approach for dynamic FDG-PET of human liver inflammation. Fourteen patients with nonalcoholic fatty liver disease were included. Each patient underwent 1 h dynamic FDG-PET/CT scan and had liver biopsy within six weeks. Three models were tested for kinetic analysis: the traditional two-tissue compartmental model with an image-derived single-blood input function (SBIF), a model with population-based dual-blood input function (DBIF), and a new model with optimization-derived DBIF through a joint estimation framework. The three models were compared using Akaike information criterion (AIC), F test and histopathologic inflammation score. Results showed that the optimization-derived DBIF model improved liver time activity curve fitting and achieved lower AIC values and higher F values than the SBIF and population-based DBIF models in all patients. The optimization-derived model significantly increased FDG K1 estimates by 101% and 27% as compared with traditional SBIF and population-based DBIF. K1 by the optimization-derived model was significantly associated with histopathologic grades of liver inflammation while the other two models did not provide a statistical significance. In conclusion, modeling of DBIF is critical for dynamic liver FDG-PET kinetic analysis in human studies. The optimization-derived DBIF model is more appropriate than SBIF and population-based DBIF for dynamic FDG-PET of liver inflammation.
Collapse
Affiliation(s)
- Guobao Wang
- Department of Radiology, University of California at Davis, Sacramento CA 95817, USA
| | - Michael T. Corwin
- Department of Radiology, University of California at Davis, Sacramento CA 95817, USA
| | - Kristin A. Olson
- Department of Pathology and Laboratory Medicine, University of California at Davis, Sacramento CA 95817, USA
| | - Ramsey D. Badawi
- Department of Radiology, University of California at Davis, Sacramento CA 95817, USA
| | - Souvik Sarkar
- Department of Internal Medicine, University of California at Davis, Sacramento CA 95817, USA
| |
Collapse
|
54
|
Zhuang M, Karakatsanis NA, Dierckx RAJO, Zaidi H. Quantitative Analysis of Heterogeneous [18F]FDG Static (SUV) vs. Patlak (Ki) Whole-body PET Imaging Using Different Segmentation Methods: a Simulation Study. Mol Imaging Biol 2018; 21:317-327. [DOI: 10.1007/s11307-018-1241-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
55
|
Ralli GP, Chappell MA, McGowan DR, Sharma RA, Higgins GS, Fenwick JD. 4D-PET reconstruction using a spline-residue model with spatial and temporal roughness penalties. Phys Med Biol 2018; 63:095013. [PMID: 29616663 PMCID: PMC5983307 DOI: 10.1088/1361-6560/aabb62] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
4D reconstruction of dynamic positron emission tomography (dPET) data can improve the signal-to-noise ratio in reconstructed image sequences by fitting smooth temporal functions to the voxel time-activity-curves (TACs) during the reconstruction, though the optimal choice of function remains an open question. We propose a spline-residue model, which describes TACs as weighted sums of convolutions of the arterial input function with cubic B-spline basis functions. Convolution with the input function constrains the spline-residue model at early time-points, potentially enhancing noise suppression in early time-frames, while still allowing a wide range of TAC descriptions over the entire imaged time-course, thus limiting bias. Spline-residue based 4D-reconstruction is compared to that of a conventional (non-4D) maximum a posteriori (MAP) algorithm, and to 4D-reconstructions based on adaptive-knot cubic B-splines, the spectral model and an irreversible two-tissue compartment ('2C3K') model. 4D reconstructions were carried out using a nested-MAP algorithm including spatial and temporal roughness penalties. The algorithms were tested using Monte-Carlo simulated scanner data, generated for a digital thoracic phantom with uptake kinetics based on a dynamic [18F]-Fluromisonidazole scan of a non-small cell lung cancer patient. For every algorithm, parametric maps were calculated by fitting each voxel TAC within a sub-region of the reconstructed images with the 2C3K model. Compared to conventional MAP reconstruction, spline-residue-based 4D reconstruction achieved >50% improvements for five of the eight combinations of the four kinetics parameters for which parametric maps were created with the bias and noise measures used to analyse them, and produced better results for 5/8 combinations than any of the other reconstruction algorithms studied, while spectral model-based 4D reconstruction produced the best results for 2/8. 2C3K model-based 4D reconstruction generated the most biased parametric maps. Inclusion of a temporal roughness penalty function improved the performance of 4D reconstruction based on the cubic B-spline, spectral and spline-residue models.
Collapse
Affiliation(s)
- George P Ralli
- Department of Oncology, University of Oxford, Old Road Campus Research Building, Roosevelt Drive, Oxford OX3 7DQ, United Kingdom
| | - Michael A Chappell
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building, Roosevelt Drive, Oxford OX3 7DQ, United Kingdom
| | - Daniel R McGowan
- Department of Oncology, University of Oxford, Old Road Campus Research Building, Roosevelt Drive, Oxford OX3 7DQ, United Kingdom
- Radiation Physics and Protection, Oxford University Hospitals NHS Foundation Trust, Churchill Hospital, Oxford OX3 7LE, United Kingdom
| | - Ricky A Sharma
- NIHR University College London Hospitals Biomedical Research Centre, UCL Cancer Institute, University College London, 72 Huntley Street, London WC1E 6DD, United Kingdom
| | - Geoff S Higgins
- Department of Oncology, University of Oxford, Old Road Campus Research Building, Roosevelt Drive, Oxford OX3 7DQ, United Kingdom
| | - John D Fenwick
- Institute of Translational Medicine, University of Liverpool, UCD Block, Royal Liverpool University Hospital, Daulby Street, Liverpool L69 3GA, United Kingdom
| |
Collapse
|
56
|
Gong K, Cheng-Liao J, Wang G, Chen KT, Catana C, Qi J. Direct Patlak Reconstruction From Dynamic PET Data Using the Kernel Method With MRI Information Based on Structural Similarity. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:955-965. [PMID: 29610074 PMCID: PMC5933939 DOI: 10.1109/tmi.2017.2776324] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Positron emission tomography (PET) is a functional imaging modality widely used in oncology, cardiology, and neuroscience. It is highly sensitive, but suffers from relatively poor spatial resolution, as compared with anatomical imaging modalities, such as magnetic resonance imaging (MRI). With the recent development of combined PET/MR systems, we can improve the PET image quality by incorporating MR information into image reconstruction. Previously, kernel learning has been successfully embedded into static and dynamic PET image reconstruction using either PET temporal or MRI information. Here, we combine both PET temporal and MRI information adaptively to improve the quality of direct Patlak reconstruction. We examined different approaches to combine the PET and MRI information in kernel learning to address the issue of potential mismatches between MRI and PET signals. Computer simulations and hybrid real-patient data acquired on a simultaneous PET/MR scanner were used to evaluate the proposed methods. Results show that the method that combines PET temporal information and MRI spatial information adaptively based on the structure similarity index has the best performance in terms of noise reduction and resolution improvement.
Collapse
|
57
|
Germino M, Carson RE. Cardiac-gated parametric images from 82 Rb PET from dynamic frames and direct 4D reconstruction. Med Phys 2017; 45:639-654. [PMID: 29205378 DOI: 10.1002/mp.12710] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2017] [Revised: 11/07/2017] [Accepted: 11/07/2017] [Indexed: 12/23/2022] Open
Abstract
PURPOSE Cardiac perfusion PET data can be reconstructed as a dynamic sequence and kinetic modeling performed to quantify myocardial blood flow, or reconstructed as static gated images to quantify function. Parametric images from dynamic PET are conventionally not gated, to allow use of all events with lower noise. An alternative method for dynamic PET is to incorporate the kinetic model into the reconstruction algorithm itself, bypassing the generation of a time series of emission images and directly producing parametric images. So-called "direct reconstruction" can produce parametric images with lower noise than the conventional method because the noise distribution is more easily modeled in projection space than in image space. In this work, we develop direct reconstruction of cardiac-gated parametric images for 82 Rb PET with an extension of the Parametric Motion compensation OSEM List mode Algorithm for Resolution-recovery reconstruction for the one tissue model (PMOLAR-1T). METHODS PMOLAR-1T was extended to accommodate model terms to account for spillover from the left and right ventricles into the myocardium. The algorithm was evaluated on a 4D simulated 82 Rb dataset, including a perfusion defect, as well as a human 82 Rb list mode acquisition. The simulated list mode was subsampled into replicates, each with counts comparable to one gate of a gated acquisition. Parametric images were produced by the indirect (separate reconstructions and modeling) and direct methods for each of eight low-count and eight normal-count replicates of the simulated data, and each of eight cardiac gates for the human data. For the direct method, two initialization schemes were tested: uniform initialization, and initialization with the filtered iteration 1 result of the indirect method. For the human dataset, event-by-event respiratory motion compensation was included. The indirect and direct methods were compared for the simulated dataset in terms of bias and coefficient of variation as a function of iteration. RESULTS Convergence of direct reconstruction was slow with uniform initialization; lower bias was achieved in fewer iterations by initializing with the filtered indirect iteration 1 images. For most parameters and regions evaluated, the direct method achieved the same or lower absolute bias at matched iteration as the indirect method, with 23%-65% lower noise. Additionally, the direct method gave better contrast between the perfusion defect and surrounding normal tissue than the indirect method. Gated parametric images from the human dataset had comparable relative performance of indirect and direct, in terms of mean parameter values per iteration. Changes in myocardial wall thickness and blood pool size across gates were readily visible in the gated parametric images, with higher contrast between myocardium and left ventricle blood pool in parametric images than gated SUV images. CONCLUSIONS Direct reconstruction can produce parametric images with less noise than the indirect method, opening the potential utility of gated parametric imaging for perfusion PET.
Collapse
Affiliation(s)
- Mary Germino
- Department of Biomedical Engineering, Yale University, P. O. Box 208048, New Haven, CT, 06520-8048, USA
| | - Richard E Carson
- Department of Biomedical Engineering, Yale University, P. O. Box 208048, New Haven, CT, 06520-8048, USA.,Department of Radiology and Biomedical Imaging, Yale University School of Medicine, P. O. Box 208048, New Haven, CT, 06520-8048, USA
| |
Collapse
|
58
|
Zaidi H, Karakatsanis N. Towards enhanced PET quantification in clinical oncology. Br J Radiol 2017; 91:20170508. [PMID: 29164924 DOI: 10.1259/bjr.20170508] [Citation(s) in RCA: 75] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Positron emission tomography (PET) has, since its inception, established itself as the imaging modality of choice for the in vivo quantitative assessment of molecular targets in a wide range of biochemical processes underlying tumour physiology. PET image quantification enables to ascertain a direct link between the time-varying activity concentration in organs/tissues and the fundamental parameters portraying the biological processes at the cellular level being assessed. However, the quantitative potential of PET may be affected by a number of factors related to physical effects, hardware and software system specifications, tracer kinetics, motion, scan protocol design and limitations in current image-derived PET metrics. Given the relatively large number of PET metrics reported in the literature, the selection of the best metric for fulfilling a specific task in a particular application is still a matter of debate. Quantitative PET has advanced elegantly during the last two decades and is now reaching the maturity required for clinical exploitation, particularly in oncology where it has the capability to open many avenues for clinical diagnosis, assessment of response to treatment and therapy planning. Therefore, the preservation and further enhancement of the quantitative features of PET imaging is crucial to ensure that the full clinical value of PET imaging modality is utilized in clinical oncology. Recent advancements in PET technology and methodology have paved the way for faster PET acquisitions of enhanced sensitivity to support the clinical translation of highly quantitative four-dimensional (4D) parametric imaging methods in clinical oncology. In this report, we provide an overview of recent advances and future trends in quantitative PET imaging in the context of clinical oncology. The pros/cons of the various image-derived PET metrics will be discussed and the promise of novel methodologies will be highlighted.
Collapse
Affiliation(s)
- Habib Zaidi
- 1 Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital , Geneva , Switzerland.,2 Department of Nuclear Medicine and Molecular Imaging, University of Groningen , Groningen , Netherlands.,3 Geneva Neuroscience Centre, University of Geneva , Geneva , Switzerland.,4 Department of Nuclear Medicine, Universityof Southern Denmark , Odense , Denmark
| | - Nicolas Karakatsanis
- 5 Division of Radiopharmaceutical Sciences, Department of Radiology, Weill Cornell Medical College of Cornell Univercity , New york, NY , USA.,6 Department of Radiology, Translational and Molecular Imaging Institute, ICAHN School of Medicine at Mount Sinai , New york, NY , USA
| |
Collapse
|
59
|
Karakatsanis NA, Tsoumpas C, Zaidi H. Quantitative PET image reconstruction employing nested expectation-maximization deconvolution for motion compensation. Comput Med Imaging Graph 2017; 60:11-21. [DOI: 10.1016/j.compmedimag.2016.11.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2016] [Revised: 09/13/2016] [Accepted: 11/11/2016] [Indexed: 12/20/2022]
|
60
|
Petibon Y, Rakvongthai Y, Fakhri GE, Ouyang J. Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies. Phys Med Biol 2017; 62:3539-3565. [PMID: 28379843 PMCID: PMC5739089 DOI: 10.1088/1361-6560/aa6394] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Dynamic PET myocardial perfusion imaging (MPI) used in conjunction with tracer kinetic modeling enables the quantification of absolute myocardial blood flow (MBF). However, MBF maps computed using the traditional indirect method (i.e. post-reconstruction voxel-wise fitting of kinetic model to PET time-activity-curves-TACs) suffer from poor signal-to-noise ratio (SNR). Direct reconstruction of kinetic parameters from raw PET projection data has been shown to offer parametric images with higher SNR compared to the indirect method. The aim of this study was to extend and evaluate the performance of a direct parametric reconstruction method using in vivo dynamic PET MPI data for the purpose of quantifying MBF. Dynamic PET MPI studies were performed on two healthy pigs using a Siemens Biograph mMR scanner. List-mode PET data for each animal were acquired following a bolus injection of ~7-8 mCi of 18F-flurpiridaz, a myocardial perfusion agent. Fully-3D dynamic PET sinograms were obtained by sorting the coincidence events into 16 temporal frames covering ~5 min after radiotracer administration. Additionally, eight independent noise realizations of both scans-each containing 1/8th of the total number of events-were generated from the original list-mode data. Dynamic sinograms were then used to compute parametric maps using the conventional indirect method and the proposed direct method. For both methods, a one-tissue compartment model accounting for spillover from the left and right ventricle blood-pools was used to describe the kinetics of 18F-flurpiridaz. An image-derived arterial input function obtained from a TAC taken in the left ventricle cavity was used for tracer kinetic analysis. For the indirect method, frame-by-frame images were estimated using two fully-3D reconstruction techniques: the standard ordered subset expectation maximization (OSEM) reconstruction algorithm on one side, and the one-step late maximum a posteriori (OSL-MAP) algorithm on the other side, which incorporates a quadratic penalty function. The parametric images were then calculated using voxel-wise weighted least-square fitting of the reconstructed myocardial PET TACs. For the direct method, parametric images were estimated directly from the dynamic PET sinograms using a maximum a posteriori (MAP) parametric reconstruction algorithm which optimizes an objective function comprised of the Poisson log-likelihood term, the kinetic model and a quadratic penalty function. Maximization of the objective function with respect to each set of parameters was achieved using a preconditioned conjugate gradient algorithm with a specifically developed pre-conditioner. The performance of the direct method was evaluated by comparing voxel- and segment-wise estimates of [Formula: see text], the tracer transport rate (ml · min-1 · ml-1), to those obtained using the indirect method applied to both OSEM and OSL-MAP dynamic reconstructions. The proposed direct reconstruction method produced [Formula: see text] maps with visibly lower noise than the indirect method based on OSEM and OSL-MAP reconstructions. At normal count levels, the direct method was shown to outperform the indirect method based on OSL-MAP in the sense that at matched level of bias, reduced regional noise levels were obtained. At lower count levels, the direct method produced [Formula: see text] estimates with significantly lower standard deviation across noise realizations than the indirect method based on OSL-MAP at matched bias level. In all cases, the direct method yielded lower noise and standard deviation than the indirect method based on OSEM. Overall, the proposed direct reconstruction offered a better bias-variance tradeoff than the indirect method applied to either OSEM and OSL-MAP. Direct parametric reconstruction as applied to in vivo dynamic PET MPI data is therefore a promising method for producing MBF maps with lower variance.
Collapse
Affiliation(s)
- Yoann Petibon
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, USA
- Department of Radiology, Harvard Medical School, Boston, USA
| | - Yothin Rakvongthai
- Division of Nuclear Medicine, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| | - Georges El Fakhri
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, USA
- Department of Radiology, Harvard Medical School, Boston, USA
| | - Jinsong Ouyang
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, USA
- Department of Radiology, Harvard Medical School, Boston, USA
| |
Collapse
|
61
|
Karpetas GE, Michail CM, Fountos GP, Kalyvas NI, Valais IG, Kandarakis IS, Panayiotakis GS. Detective quantum efficiency (DQE) in PET scanners: A simulation study. Appl Radiat Isot 2017; 125:154-162. [PMID: 28437735 DOI: 10.1016/j.apradiso.2017.04.018] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2016] [Revised: 03/26/2017] [Accepted: 04/10/2017] [Indexed: 11/18/2022]
Abstract
The aim of the present study is to introduce the detective quantum efficiency (DQE) for the image quality assessment of positron emission tomography (PET) scanners. For this purpose, a thin layer chromatography (TLC) plane source was simulated using a previously validated, scanner and source geometry, Monte Carlo (MC) model. The model was developed with the Geant4 application for tomographic emission (GATE) MC package and reconstructed images obtained with the software for tomographic image reconstruction (STIR), with cluster computing. The GE Discovery ST PET scanner was simulated by using a previously validated code. A plane source consisting of a TLC plate, was simulated by a layer of silica gel on aluminum (Al) foil substrate, immersed in 18F-FDG bath solution (1MBq). Image quality was assessed in terms of the modulation transfer function (MTF) and the normalized noise power spectrum (NNPS) in order to obtain the detective quantum efficiency (DQE). MTF curves were estimated from transverse reconstructed images of the plane source, whereas the NNPS data were estimated from the corresponding coronal images. Images were reconstructed by the maximum likelihood estimation ordered subsets maximum a posteriori one step late (MLE)-OS-MAP-OSL algorithm, by using various subsets 1-21) and iterations 1-20). MTF values were found to increase up to the 12th iteration whereas remain almost constant thereafter. However, the range of the increase in the MTF is limited as the number of subsets increases. The noise levels were found to increase with the corresponding increase of both the number of iterations and subsets. The maximum NNPS value (0.517mm2) was observed for the 420 MLEM-equivalent iterations reconstructed image at 0cycles/mm. Finally DQE values were found to increase for spatial frequencies up to 0.038cycles/mm and to decrease thereafter with the corresponding increase in both number of iterations and subsets. The maximum DQE value (0.48 at 0.038cycles/mm) was obtained for the 8 MLEM-equivalent iterations image. The simulated PET evaluation method based on the TLC plane source can be useful in the quality control and in the further development of PET and SPECT scanners though GATE simulations.
Collapse
Affiliation(s)
- George E Karpetas
- Department of Medical Physics, Faculty of Medicine, University of Patras, 265 00 Patras, Greece
| | - Christos M Michail
- Radiation Physics, Materials Technology and Biomedical Imaging Laboratory, Department of Biomedical Engineering, Technological Educational Institute of Athens, Egaleo 122 10, Athens, Greece
| | - George P Fountos
- Radiation Physics, Materials Technology and Biomedical Imaging Laboratory, Department of Biomedical Engineering, Technological Educational Institute of Athens, Egaleo 122 10, Athens, Greece.
| | - Nektarios I Kalyvas
- Radiation Physics, Materials Technology and Biomedical Imaging Laboratory, Department of Biomedical Engineering, Technological Educational Institute of Athens, Egaleo 122 10, Athens, Greece
| | - Ioannis G Valais
- Radiation Physics, Materials Technology and Biomedical Imaging Laboratory, Department of Biomedical Engineering, Technological Educational Institute of Athens, Egaleo 122 10, Athens, Greece
| | - Ioannis S Kandarakis
- Radiation Physics, Materials Technology and Biomedical Imaging Laboratory, Department of Biomedical Engineering, Technological Educational Institute of Athens, Egaleo 122 10, Athens, Greece
| | - George S Panayiotakis
- Department of Medical Physics, Faculty of Medicine, University of Patras, 265 00 Patras, Greece
| |
Collapse
|