51
|
A Comprehensive Review on the Corrosion Pathways of Titanium Dental Implants and Their Biological Adverse Effects. METALS 2020. [DOI: 10.3390/met10091272] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The main aim of this work was to perform a comprehensive review of findings reported by previous studies on the corrosion of titanium dental implants and consequent clinical detrimental effects to the patients. Most studies were performed by in vitro electrochemical tests and complemented with microscopic techniques to evaluate the corrosion behavior of the protective passive oxide film layer, namely TiO2. Results revealed that bacterial accumulation, dietary, inflammation, infection, and therapeutic solutions decrease the pH of the oral environment leading to the corrosion of titanium. Some therapeutic products used as mouthwash negatively affect the corrosion behavior of the titanium oxide film and promote changes on the implant surface. In addition, toothpaste and bleaching agents, can amplify the chemical reactivity of titanium since fluor ions interacting with the titanium oxide film. Furthermore, the number of in vivo studies is limited although corrosion signs have been found in retrieved implants. Histological evaluation revealed titanium macro- and micro-scale particles on the peri-implant tissues. As a consequence, progressive damage of the dental implants and the evolution of inflammatory reactions depend on the size, chemical composition, and concentration of submicron- and nanoparticles in the surrounding tissues and internalized by the cells. In fact, the damage of the implant surfaces results in the loss of material that compromises the implant surfaces, implant-abutment connections, and the interaction with soft tissues. The corrosion can be an initial trigger point for the development of biological or mechanical failures in dental implants.
Collapse
|
52
|
Fretwurst T, Müller J, Larsson L, Bronsert P, Hazard D, Castilho RM, Kohal R, Nelson K, Iglhaut G. Immunohistological composition of peri-implantitis affected tissue around ceramic implants-A pilot study. J Periodontol 2020; 92:571-579. [PMID: 32839977 DOI: 10.1002/jper.20-0169] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2020] [Revised: 06/30/2020] [Accepted: 07/10/2020] [Indexed: 12/26/2022]
Abstract
BACKGROUND Aim of the pilot study was the histologic classification of the inflamed peri-implant soft tissue around ceramic implants (CI) in comparison with titanium implants (TI). METHODS Peri-implant tissue were retrieved from 15 patients (aged 34 to 88 years, seven males/eight females) with severe peri-implantitis (eight CI, seven TI). The peri-implant soft tissue samples were retrieved from the sites during scheduled removal of the implant and prepared for immunohistochemical analysis. Monoclonal antibodies (targeting CD3, CD20, CD138, and CD68) were used to identify T- and B-cells, plasma cells and macrophages. Quantitative assessment was performed by one histologically trained investigator. Linear mixed regression models were used. RESULTS A similar numerical distribution of the cell population was found in peri-implantitis around CI compared with TI. CD3 (TI, 17% to 85% versus CI, 20% to 70% of total cell number) and CD138 (TI, 1% to 73% versus CI, 12% to 69% of total cell number) were predominantly expressed. Notably, patient-individual differences of numerical cell distribution were detected. Co-localization of B- and T-lymphocytes was observed. CONCLUSIONS Peri-implantitis around CI in comparison with TI seems to have a similar histological appearance. Differences in cellular composition of peri-implantitis lesions might also depend on the patient's specific immune status and not only on the material used.
Collapse
Affiliation(s)
- Tobias Fretwurst
- Department of Oral and Craniomaxillofacial Surgery, Translational Implantology, Center for Dental Medicine, University Medical Center, Freiburg, Baden-Württemberg, Germany
| | - Janina Müller
- Department of Oral and Craniomaxillofacial Surgery, Translational Implantology, Center for Dental Medicine, University Medical Center, Freiburg, Baden-Württemberg, Germany
| | - Lena Larsson
- Department of Periodontology, Institute of Odontology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Peter Bronsert
- Institute of Surgical Pathology, University Medical Center, Freiburg, Germany, Tumorbank Comprehensive Cancer Center Freiburg, Medical Center- University of Freiburg, Freiburg, Germany, Faculty of Medicine, University of Freiburg, Freiburg, Baden-Württemberg, Germany
| | - Derek Hazard
- Institute of Medical Biometry and Statistics, Faculty of Medicine and Medical Center, University of Freiburg, Freiburg, Baden-Württemberg, Germany
| | - Rogerio M Castilho
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Michigan, USA.,Laboratory of Epithelial Biology, Department of Periodontics and Oral Medicine, University of Michigan School, Ann Arbor, Michigan, USA
| | - Ralf Kohal
- Department of Prosthetic Dentistry, Center for Dental Medicine, University Medical Center Freiburg, Freiburg, Baden-Württemberg, Germany
| | - Katja Nelson
- Department of Oral and Craniomaxillofacial Surgery, Translational Implantology, Center for Dental Medicine, University Medical Center, Freiburg, Baden-Württemberg, Germany
| | - Gerhard Iglhaut
- Department of Oral and Craniomaxillofacial Surgery, Translational Implantology, Center for Dental Medicine, University Medical Center, Freiburg, Baden-Württemberg, Germany
| |
Collapse
|
53
|
Kotsakis GA, Black R, Kum J, Berbel L, Sadr A, Karoussis I, Simopoulou M, Daubert D. Effect of implant cleaning on titanium particle dissolution and cytocompatibility. J Periodontol 2020; 92:580-591. [PMID: 32846000 DOI: 10.1002/jper.20-0186] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Revised: 07/13/2020] [Accepted: 07/18/2020] [Indexed: 11/07/2022]
Abstract
BACKGROUND Peri-implantitis treatments are mainly based on protocols for teeth but have not shown favorable outcomes for implants. The potential role of titanium dissolution products in peri-implantitis necessitate the consideration of material properties in devising treatment protocols. We assessed implant cleaning interventions on (1) bacterial removal from Ti-bound biofilms, (2) Ti surface alterations and related Ti particle dissolution, and (3) cytocompatibility. METHODS Acid-etched Ti discs were inoculated with human peri-implant plaque biofilms and mechanical antimicrobial interventions were applied on the Ti-bound biofilms for 30 seconds each: (1) rotary nylon brush; (2) Ti brush; (3) water-jet on high and (4) low, and compared to sterile, untreated and Chlorhexidine-treated controls. We assessed colony forming units (CFU) counts, biofilm removal, surface changes via scanning electron microscopy (SEM) and atomic force microscopy (AFM), and Ti dissolution via light microscopy and Inductively-coupled Mass Spectrometry (ICP-MS). Biological effects of Ti particles and surfaces changes were assessed using NIH/3T3 fibroblasts and MG-63 osteoblastic cell lines, respectively. RESULTS Sequencing revealed that the human biofilm model supported a diverse biofilm including known peri-implant pathogens. WJ and Nylon brush were most effective in reducing CFU counts (P < 0.01 versus control), whereas Chlorhexidine was least effective; biofilm imaging results were confirmatory. Ti brushes led to visible streaks on the treated surfaces, reduced corrosion resistance and increased Ti dissolution over 30 days of material aging as compared to controls, which increase was amplified in the presence of bacteria (all P-val < 0.05). Ti particles exerted cytotoxic effects against fibroblasts, whereas surfaces altered by Ti brushes exhibited reduced osteoconductivity versus controls (P < 0.05). CONCLUSIONS Present findings support that mechanical treatment strategies selected for implant biofilm removal may lead to Ti dissolution. Ti dissolution should become an important consideration in the clinical selection of peri-implantitis treatments and a necessary criterion for the regulatory approval of instruments for implant hygiene.
Collapse
Affiliation(s)
| | | | - Jason Kum
- Private Practice, Indianapolis, Indiana, USA
| | - Larissa Berbel
- Nuclear and Energy Research Institute-IPEN, University of São Paulo, São Paulo, Brazil
| | - Ali Sadr
- Comprehensive Dentistry, University of Washington, Seattle, Washington, USA
| | - Ioannis Karoussis
- Periodontics, National and Kapodistrian University of Athens, Athens, Greece
| | - Mara Simopoulou
- Experimental Physiology, National and Kapodistrian University of Athens, Athens, Greece
| | - Diane Daubert
- Periodontics, University of Washington, Seattle, Washington, USA
| |
Collapse
|
54
|
Abstract
Osseointegrated dental implants are a revolutionary tool in the armament of reconstructive dentistry, employed to replace missing teeth and restore masticatory, occlusal, and esthetic functions. Like natural teeth, the orally exposed part of dental implants offers a pristine nonshedding surface for salivary pellicle-mediated microbial adhesion and biofilm formation. In early colonization stages, these bacterial communities closely resemble those of healthy periodontal sites, with lower diversity. Because the peri-implant tissues are more susceptible to endogenous oral infections, understanding of the ecological triggers that underpin the microbial pathogenesis of peri-implantitis is central to developing improved prevention, diagnosis, and therapeutic strategies. The advent of next-generation sequencing (NGS) technologies, notably applied to 16S ribosomal RNA gene amplicons, has enabled the comprehensive taxonomic characterization of peri-implant bacterial communities in health and disease, revealing a differentially abundant microbiota between these 2 states, or with periodontitis. With that, the peri-implant niche is highlighted as a distinct ecosystem that shapes its individual resident microbial community. Shifts from health to disease include an increase in diversity and a gradual depletion of commensals, along with an enrichment of classical and emerging periodontal pathogens. Metatranscriptomic profiling revealed similarities in the virulence characteristics of microbial communities from peri-implantitis and periodontitis, nonetheless with some distinctive pathways and interbacterial networks. Deeper functional assessment of the physiology and virulence of the well-characterized microbial communities of the peri-implant niche will elucidate further the etiopathogenic mechanisms and drivers of the disease.
Collapse
Affiliation(s)
- G N Belibasakis
- Division of Oral Diseases, Department of Dental Medicine, Karolinska Institute, Huddinge, Sweden
| | - D Manoil
- Division of Oral Diseases, Department of Dental Medicine, Karolinska Institute, Huddinge, Sweden
| |
Collapse
|
55
|
Demonstration of a SiC Protective Coating for Titanium Implants. MATERIALS 2020; 13:ma13153321. [PMID: 32722625 PMCID: PMC7435394 DOI: 10.3390/ma13153321] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 07/16/2020] [Accepted: 07/23/2020] [Indexed: 12/02/2022]
Abstract
To mitigate the corrosion of titanium implants and improve implant longevity, we investigated the capability to coat titanium implants with SiC and determined if the coating could remain intact after simulated implant placement. Titanium disks and titanium implants were coated with SiC using plasma-enhanced chemical vapor deposition (PECVD) and were examined for interface quality, chemical composition, and coating robustness. SiC-coated titanium implants were torqued into a Poly(methyl methacrylate) (PMMA) block to simulate clinical implant placement followed by energy dispersive spectroscopy to determine if the coating remained intact. After torquing, the atomic concentration of the detectable elements (silicon, carbon, oxygen, titanium, and aluminum) remained relatively unchanged, with the variation staying within the detection limits of the Energy Dispersive Spectroscopy (EDS) tool. In conclusion, plasma-enhanced chemical vapor deposited SiC was shown to conformably coat titanium implant surfaces and remain intact after torquing the coated implants into a material with a similar hardness to human bone mass.
Collapse
|
56
|
Salivary Levels of Titanium, Nickel, Vanadium, and Arsenic in Patients Treated with Dental Implants: A Case-Control Study. J Clin Med 2020; 9:jcm9051264. [PMID: 32349296 PMCID: PMC7288178 DOI: 10.3390/jcm9051264] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2020] [Revised: 04/19/2020] [Accepted: 04/23/2020] [Indexed: 12/12/2022] Open
Abstract
Background: Recent articles have hypothesized a possible correlation between dental implants dissolution products and peri-implantitis. The null hypothesis tested in this case-control study was that there would be no differences in salivary concentrations of titanium (Ti), vanadium (V), nickel (Ni) and arsenic (As) ions among patients with dental implants, healthy (Group A) or affected by peri-implantitis (Group B), compared to subjects without implants and/or metallic prosthetic restorations (Group C). Methods: Inductively coupled plasma mass spectrometry was used to analyze saliva samples. One-way repeated-measure analysis of variance (ANOVA) was used to identify statistically significant differences in the salivary level of Ti, V, Ni and As between the three groups. Results: A total of 100 patients were enrolled in the study (42 males and 58 females), distributed in three groups: 50 patients in Group C, 26 patients in Group B and 24 patients Group B. In our study, concentrations of metallic ions were higher in Group A and B, compared to the control group, with the exception of vanadium. However, there were no statistically significant differences (p > 0.05) for metallic ions concentrations between Group A and Group B. Conclusions: Based on our results, there are no differences in titanium or other metals concentrations in saliva of patients with healthy or diseased implants.
Collapse
|
57
|
Xu LN, Yu XY, Chen WQ, Zhang SM, Qiu J. Biocorrosion of pure and SLA titanium surfaces in the presence of Porphyromonas gingivalis and its effects on osteoblast behavior. RSC Adv 2020; 10:8198-8206. [PMID: 35497867 PMCID: PMC9049922 DOI: 10.1039/d0ra00154f] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2020] [Accepted: 02/20/2020] [Indexed: 01/25/2023] Open
Abstract
Objective: The study aims to investigate the biocorrosion behavior of Porphyromonas gingivalis on pure and SLA titanium surfaces and its effects on surface characteristics and osteoblast behavior. Methods: Pure and SLA titanium specimens were immersed in culture medium with P. gingivalis and incubated for 7 days. P. gingivalis colonization on the pure and SLA titanium surfaces was observed by scanning electron microscopy (SEM). The pure and SLA titanium surface characteristics were analyzed via X-ray photoelectron spectroscopy (XPS), surface roughness and surface wettability. The corrosion behaviors of pure and SLA titanium specimens were evaluated by electrochemical corrosion test. The osteoblast behavior of MC3T3-E1 cells on the pure and SLA titanium surfaces after P. gingivalis colonization was investigated by cell adhesion and western blot assays. Results: P. gingivalis colonized on the pure and SLA titanium surfaces was observed by SEM. The XPS analysis demonstrated reductions in the relative levels of titanium and oxygen and obvious reductions of dominant titanium dioxide (TiO2) on both titanium surfaces after immersing the metal in P. gingivalis culture. In addition, their roughness and wettability were changed. Correspondingly, the electrochemical corrosion test results revealed significant decreases in the corrosion resistance and increases in the corrosion rate of the pure and SLA titanium specimens after immersion in P. gingivalis culture. The results of the in vitro study showed that the pre-corroded pure and SLA titanium surfaces by P. gingivalis exhibited lower osteocompatibility and down-regulated the adhesion, spreading and osteogenic differentiation abilities of MC3T3-E1 cells. Conclusions: P. gingivalis was able to colonize on the pure and SLA titanium surfaces and weaken their surface properties, especially a decrease in the protective TiO2 film, which induced the biocorrosion and further negatively affected the osteoblast behavior. The study demonstrated that P. gingivalis could colonize on pure and SLA titanium surfaces and weaken their surface properties, especially the protective TiO2 film, which induced the biocorrosion and further negatively affected osteoblast behavior.![]()
Collapse
Affiliation(s)
- Li-na Xu
- Department of Oral Implantology
- Affiliated Hospital of Stomatology
- Nanjing Medical University
- Nanjing
- PR China
| | - Xiao-yu Yu
- Department of Oral Implantology
- Affiliated Hospital of Stomatology
- Nanjing Medical University
- Nanjing
- PR China
| | - Wan-qing Chen
- Department of Oral Implantology
- Affiliated Hospital of Stomatology
- Nanjing Medical University
- Nanjing
- PR China
| | - Song-mei Zhang
- Department of General Dentistry
- Eastman Institute for Oral Health
- University of Rochester
- Rochester
- USA
| | - Jing Qiu
- Department of Oral Implantology
- Affiliated Hospital of Stomatology
- Nanjing Medical University
- Nanjing
- PR China
| |
Collapse
|
58
|
Al Otaibi A, Sherif ESM, Al-Rifaiy MQ, Zinelis S, Al Jabbari YS. Corrosion resistance of coupled sandblasted, large-grit, acid-etched (SLA) and anodized Ti implant surfaces in synthetic saliva. Clin Exp Dent Res 2019; 5:452-459. [PMID: 31687177 PMCID: PMC6820584 DOI: 10.1002/cre2.198] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Revised: 02/16/2019] [Accepted: 02/18/2019] [Indexed: 11/17/2022] Open
Abstract
Purpose The purpose of this study was to investigate the corrosion resistance of galvanically coupled SLA and anodized implant surfaces with a Co‐Cr alloy. Materials and Methods Three groups were included in this study. The first (SLA) was composed of SLA implants (Institut Straumann, Basel, Switzerland), the second (ANO) of NobelReplace® (Nobel Biocare, Göteborg, Sweden), and the third (MIX) of both implant systems combined. All groups were assembled with a single Co‐Cr superstructure. Electrochemical testing included open‐circuit potential, electrochemical impedance spectroscopy, cyclic potentiodynamic polarization, and chronoamperometric current‐time measurements. The quantitative results (EOCP, ECORR, ICORR, EPROT, RP, and ICA) were statistically analyzed by one‐way ANOVA and Tukey's post‐hoc multiple comparison test (α = 0.05) Results All the aforementioned parameters showed statistically significant differences apart from ECORR and EPROT. The evaluation of qualitative and quantitative results showed that although SLA had higher corrosion resistance compared with ANO, it had less resistance to pitting corrosion. This means that SLA showed increased resistance to uniform corrosion but less resistance if pitting corrosion was initiated. In all cases, MIX showed intermediate behavior. Conclusion The corrosion resistance of implant‐retained superstructures is dependent on the electrochemical properties of the implants involved, and thus different degrees of intraoral corrosion resistance among different implant systems are anticipated.
Collapse
Affiliation(s)
- Ala'a Al Otaibi
- Dental Biomaterials Research and Development Chair, College of Dentistry King Saud University Riyadh Saudi Arabia.,Department of Prosthetic Dental Science, College of Dentistry King Saud University Riyadh Saudi Arabia
| | - El-Sayed M Sherif
- Dental Biomaterials Research and Development Chair, College of Dentistry King Saud University Riyadh Saudi Arabia.,Center of Excellence for Research in Engineering Materials (CEREM) King Saud University Riyadh Saudi Arabia.,Electrochemistry and Corrosion Laboratory, Department of Physical Chemistry National Research Centre (NRC) Cairo Egypt
| | - Mohammed Q Al-Rifaiy
- Dental Biomaterials Research and Development Chair, College of Dentistry King Saud University Riyadh Saudi Arabia.,Department of Prosthetic Dental Science, College of Dentistry King Saud University Riyadh Saudi Arabia
| | - Spiros Zinelis
- Department of Biomaterials, School of Dentistry National and Kapodistrian University of Athens Athens Greece.,Dental Biomaterials Research and Development Chair, College of Dentistry King Saud University Riyadh Saudi Arabia
| | - Youssef S Al Jabbari
- Dental Biomaterials Research and Development Chair, College of Dentistry King Saud University Riyadh Saudi Arabia.,Department of Prosthetic Dental Science, College of Dentistry King Saud University Riyadh Saudi Arabia
| |
Collapse
|
59
|
Nano-scale modification of titanium implant surfaces to enhance osseointegration. Acta Biomater 2019; 94:112-131. [PMID: 31128320 DOI: 10.1016/j.actbio.2019.05.045] [Citation(s) in RCA: 232] [Impact Index Per Article: 46.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Revised: 05/15/2019] [Accepted: 05/19/2019] [Indexed: 12/16/2022]
Abstract
The main aim of this review study was to report the state of art on the nano-scale technological advancements of titanium implant surfaces to enhance the osseointegration process. Several methods of surface modification are chronologically described bridging ordinary methods (e.g. grit blasting and etching) and advanced physicochemical approaches such as 3D-laser texturing and biomimetic modification. Functionalization procedures by using proteins, peptides, and bioactive ceramics have provided an enhancement in wettability and bioactivity of implant surfaces. Furthermore, recent findings have revealed a combined beneficial effect of micro- and nano-scale modification and biomimetic functionalization of titanium surfaces. However, some technological developments of implant surfaces are not commercially available yet due to costs and a lack of clinical validation for such recent surfaces. Further in vitro and in vivo studies are required to endorse the use of enhanced biomimetic implant surfaces. STATEMENT OF SIGNIFICANCE: Grit-blasting followed by acid-etching is currently used for titanium implant modifications, although recent technological biomimetic physicochemical methods have revealed enhanced osteoconductive and anti-microbial outcomes. An improvement in wettability and bioactivity of titanium implant surfaces has been accomplished by combining micro and nano-scale modification and functionalization with protein, peptides, and bioactive compounds. Such morphological and chemical modification of the titanium surfaces induce the migration and differentiation of osteogenic cells followed by an enhancement of the mineral matrix formation that accelerate the osseointegration process. Additionally, the incorporation of bioactive molecules into the nanostructured surfaces is a promising strategy to avoid early and late implant failures induced by the biofilm accumulation.
Collapse
|
60
|
Metal Nanoparticles Released from Dental Implant Surfaces: Potential Contribution to Chronic Inflammation and Peri-Implant Bone Loss. MATERIALS 2019; 12:ma12122036. [PMID: 31242601 PMCID: PMC6630980 DOI: 10.3390/ma12122036] [Citation(s) in RCA: 86] [Impact Index Per Article: 17.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/29/2019] [Revised: 06/18/2019] [Accepted: 06/20/2019] [Indexed: 02/06/2023]
Abstract
Peri-implantitis is an inflammatory disease affecting tissues surrounding dental implants. Although it represents a common complication of dental implant treatments, the underlying mechanisms have not yet been fully described. The aim of this study is to identify the role of titanium nanoparticles released form the implants on the chronic inflammation and bone lysis in the surrounding tissue. We analyzed the in vitro effect of titanium (Ti) particle exposure on mesenchymal stem cells (MSCs) and fibroblasts (FU), evaluating cell proliferation by MTT test and the generation of reactive oxygen species (ROS). Subsequently, in vivo analysis of peri-implant Ti particle distribution, histological, and molecular analyses were performed. Ti particles led to a time-dependent decrease in cell viability and increase in ROS production in both MSCs and FU. Tissue analyses revealed presence of oxidative stress, high extracellular and intracellular Ti levels and imbalanced bone turnover. High expression of ZFP467 and the presence of adipose-like tissue suggested dysregulation of the MSC population; alterations in vessel morphology were identified. The results suggest that Ti particles may induce the production of high ROS levels, recruiting abnormal quantity of neutrophils able to produce high level of metalloproteinase. This induces the degradation of collagen fibers. These events may influence MSC commitment, with an imbalance of bone regeneration.
Collapse
|
61
|
Effect of Titanium Particles on the Voltage-Gated Potassium Channel Currents in Trigeminal Root Ganglion Neurons. IMPLANT DENT 2019; 28:54-61. [PMID: 30507652 DOI: 10.1097/id.0000000000000848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
PURPOSE Titanium (Ti) is the key material used in dental implants because of its excellent biocompatibility. But wear and corrosion Ti particles had been widely reported to induce inflammation and promote bone absorption. However, little information is known about the damage of Ti particles on neurons. MATERIALS AND METHODS Trigeminal root ganglion (TRG) neurons were exposed to Ti particles (<5 μm). The electrophysiological properties of 2 main subtypes of voltage-gated potassium channels (VGPCs) (KA and KV) were examined by whole-cell patch-clamp techniques. RESULT With the presence of 0.25 mg/mL Ti particles, amplitudes of IK, A and IK, V were both obviously inhibited. For IK, A, the activation V1/2 shifted to the depolarizing direction with an increased k value, whereas the inactivation V1/2 showed obvious hyperdepolarizing shifts. For IK, V, 0.5 mg/mL Ti particles produced a depolarizing shift of activation V1/2 with a slower activation rate. No significant changes of its inactivation kinetics were found. CONCLUSION Titanium (Ti) particles might alter the electrophysiological properties of VGPCs on TRG neurons, which are likely to further influence the excitability of neurons.
Collapse
|
62
|
Corne P, De March P, Cleymand F, Geringer J. Fretting-corrosion behavior on dental implant connection in human saliva. J Mech Behav Biomed Mater 2019; 94:86-92. [DOI: 10.1016/j.jmbbm.2019.02.025] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Revised: 02/20/2019] [Accepted: 02/21/2019] [Indexed: 01/01/2023]
|
63
|
Enhanced corrosion resistance of zinc-containing nanowires-modified titanium surface under exposure to oxidizing microenvironment. J Nanobiotechnology 2019; 17:55. [PMID: 30992009 PMCID: PMC6466780 DOI: 10.1186/s12951-019-0488-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Accepted: 04/09/2019] [Indexed: 12/19/2022] Open
Abstract
Titanium (Ti) and its alloys as bio-implants have excellent biocompatibilities and osteogenic properties after modification of chemical composition and topography via various methods. The corrosion resistance of these modified materials is of great importance for changing oral system, while few researches have reported this point. Recently, oxidative corrosion induced by cellular metabolites has been well concerned. In this study, we explored the corrosion behaviors of four common materials (commercially pure Ti, cp-Ti; Sandblasting and acid etching-modified Ti, Ti-SLA; nanowires-modified Ti, Ti-NW; and zinc-containing nanowires-modified Ti, Ti-NW-Zn) with excellent biocompatibilities and osteogenic capacities under the macrophages induced-oxidizing microenvironment. The results showed that the materials immersed into a high oxidizing environment were more vulnerable to corrode. Meanwhile, different surfaces also showed various corrosion susceptibilities under oxidizing condition. Samples embed with zinc element exhibited more excellent corrosion resistance compared with other three surfaces exposure to excessive H2O2. Besides, we found that zinc-decorated Ti surfaces inhibited the adhesion and proliferation of macrophages on its surface and induced the M2 states of macrophages to better healing and tissue reconstruction. Most importantly, zinc-decorated Ti surfaces markedly increased the expressions of antioxidant enzyme relative genes in macrophages. It improved the oxidation microenvironment around the materials and further protected their properties. In summary, our results demonstrated that Ti-NW-Zn surfaces not only provided excellent corrosion resistance properties, but also inhibited the adhesion of macrophages. These aspects were necessary for maintaining osseointegration capacity and enhancing the corrosion resistance of Ti in numerous medical applications, particularly in dentistry.
Collapse
|
64
|
Bianchini MA, Galarraga-Vinueza ME, Apaza-Bedoya K, De Souza JM, Magini R, Schwarz F. Two to six-year disease resolution and marginal bone stability rates of a modified resective-implantoplasty therapy in 32 peri-implantitis cases. Clin Implant Dent Relat Res 2019; 21:758-765. [PMID: 30985073 DOI: 10.1111/cid.12773] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Revised: 03/20/2019] [Accepted: 03/26/2019] [Indexed: 12/29/2022]
Abstract
BACKGROUND Different nonsurgical, antibacterial, surgical, and regenerative approaches to treat peri-implantitis have been proposed, but there is no an actual "gold" standard treatment showing the most favorable results to counteract peri-implantitis effects. PURPOSE To evaluate radiographically and clinically the disease resolution and peri-implant marginal bone stability rates of peri-implantitis cases treated through a combined resective-implantoplasty therapy in a moderate to long-term period. MATERIALS AND METHODS Records of patients diagnosed with peri-implantitis and treated through the same protocol applying a combined resective-implantoplasty therapy with minimum 2-year follow-up were screened. Eligible patients were contacted and asked to undergo clinical and radiologic examination. Progressive marginal bone loss, bleeding on probing, suppuration, implant mobility, and implant fracture were considered to establish the disease resolution rate and peri-implant bone stability of the treated implants. RESULTS Twenty-three patients with 32 treated implants fulfilled the inclusion criteria. Over the 2 to 6-year follow-up, (mean time: 3.4 ± 1.5 years), the disease resolution rate was 83% (patient level) and 87% (implant level). Four implants (13%) were lost or removed due to continuous MBL and osseointegration failure. At follow-up, peri-implant marginal bone remained stable with no further bone loss in 87% of the treated implants. BOP was absent in 89.3% (implant level), suppuration was resolved in all cases, and no pain or implant fracture was reported. CONCLUSION Implantoplasty treated cases showed high disease resolution rate and peri-implant marginal bone stability. This surgical antibiofilm strategy can counteract peri-implantitis progression providing an adequate environment for implant function and longevity over a moderate to long-term period.
Collapse
Affiliation(s)
- Marco A Bianchini
- Post-Graduate Program in Implant Dentistry (PPGO), Federal University of Santa Catarina (UFSC), Florianópolis, South Carolina, Brazil
| | - Maria E Galarraga-Vinueza
- Post-Graduate Program in Implant Dentistry (PPGO), Federal University of Santa Catarina (UFSC), Florianópolis, South Carolina, Brazil.,Department of Oral Surgery and Implantology, Carolinum, Johann Wolfgang Goethe-University Frankfurt, Frankfurt, Germany
| | - Karin Apaza-Bedoya
- Post-Graduate Program in Implant Dentistry (PPGO), Federal University of Santa Catarina (UFSC), Florianópolis, South Carolina, Brazil
| | - Jose M De Souza
- Post-Graduate Program in Implant Dentistry (PPGO), Federal University of Santa Catarina (UFSC), Florianópolis, South Carolina, Brazil
| | - Ricardo Magini
- Post-Graduate Program in Implant Dentistry (PPGO), Federal University of Santa Catarina (UFSC), Florianópolis, South Carolina, Brazil
| | - Frank Schwarz
- Department of Oral Surgery and Implantology, Carolinum, Johann Wolfgang Goethe-University Frankfurt, Frankfurt, Germany
| |
Collapse
|
65
|
Monje A, Insua A, Wang HL. Understanding Peri-Implantitis as a Plaque-Associated and Site-Specific Entity: On the Local Predisposing Factors. J Clin Med 2019; 8:E279. [PMID: 30823574 PMCID: PMC6406659 DOI: 10.3390/jcm8020279] [Citation(s) in RCA: 55] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Revised: 02/20/2019] [Accepted: 02/21/2019] [Indexed: 12/22/2022] Open
Abstract
The prevalence of implant biological complications has grown enormously over the last decade, in concordance with the impact of biofilm and its byproducts upon disease development. Deleterious habits and systemic conditions have been regarded as risk factors for peri-implantitis. However, little is known about the influence of local confounders upon the onset and progression of the disease. The present narrative review therefore describes the emerging local predisposing factors that place dental implants/patients at risk of developing peri-implantitis. A review is also made of the triggering factors capable of inducing peri-implantitis and of the accelerating factors capable of interfering with the progression of the disease.
Collapse
Affiliation(s)
- Alberto Monje
- Department of Periodontology, Universitat Internacional de Catalunya, 08195 Barcelona, Spain.
- Division of Periodontics, CICOM Periodoncia, 06011 Badajoz, Badajoz, Spain Santiago de Compostela, Spain.
| | - Angel Insua
- Division of Periodontics, CICOM Periodoncia, 06011 Badajoz, Badajoz, Spain Santiago de Compostela, Spain.
| | - Hom-Lay Wang
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI 48109, USA.
| |
Collapse
|
66
|
Donovan TE, Marzola R, Murphy KR, Cagna DR, Eichmiller F, McKee JR, Metz JE, Albouy JP, Troeltzsch M. Annual review of selected scientific literature: A report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 2018; 120:816-878. [DOI: 10.1016/j.prosdent.2018.09.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2018] [Accepted: 09/24/2018] [Indexed: 02/08/2023]
|
67
|
Peñarrieta-Juanito G, Sordi MB, Henriques B, Dotto MER, Teughels W, Silva FS, Magini RS, Souza JCM. Surface damage of dental implant systems and ions release after exposure to fluoride and hydrogen peroxide. J Periodontal Res 2018; 54:46-52. [PMID: 30368813 DOI: 10.1111/jre.12603] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2018] [Revised: 07/20/2018] [Accepted: 08/02/2018] [Indexed: 01/16/2023]
Abstract
OBJECTIVE The aim of this study was to evaluate surface changes on dental implant systems and ions release after immersion in fluoride and hydrogen peroxide. METHODS Ten implant-abutment assemblies were embedded in acrylic resin and cross-sectioned along the implant vertical axis. Samples were wet ground and polished. Delimited areas of groups of samples were immersed in 1.23% sodium fluoride gel (F) or in 35% hydrogen peroxide (HP) for 16 min. Gels (n = 3) were collected from the implant surfaces and analyzed by inductively coupled plasma mass spectrometry (ICP-MS), to detect the concentration of metallic ions released from the implant systems. Selected areas of the abutment and implant (n = 15) were analyzed by atomic force microscopy (AFM) and scanning electron microscopy (SEM). RESULTS SEM images revealed surface topographic changes on implant-abutment joints after immersion in fluoride. Implants showed excessive oxidation within loss of material, while abutment surfaces revealed intergranular corrosion after immersion in fluoride. ICP-MS results revealed a high concentration of Ti, Al, V ions in fluoride after contact with the implant systems. Localized corrosion of implant systems could not be detected by SEM after immersion in hydrogen peroxide although the profilometry showed increase in roughness. ICP-MS showed the release of metallic ions in hydrogen peroxide medium after contact with dental implants. CONCLUSION Therapeutical substances such as fluorides and hydrogen peroxide can promote the degradation of titanium-based dental implant and abutments leading to the release of toxic ions.
Collapse
Affiliation(s)
- Gabriella Peñarrieta-Juanito
- Postgraduate Program in Dentistry (PPGO), Department of Dentistry, Division of Implant Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| | - Mariane B Sordi
- Postgraduate Program in Dentistry (PPGO), Department of Dentistry, Division of Implant Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| | - Bruno Henriques
- Laboratory of Ceramic and Composite Materials (CERMAT), Department of Mechanical Engineering (EMC), Federal University of Santa Catarina (UFSC), Florianópolis, Brazil.,Center for Microelectromechanical Systems (CMEMS-UMINHO), University of Minho, Guimarães, Portugal
| | - Marta E R Dotto
- Department of Physics, Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| | - Wim Teughels
- Department of Oral Health Sciences, University Hospitals Leuven, Katholieke Universiteit Leuven, Leuven, Belgium
| | - Filipe S Silva
- Center for Microelectromechanical Systems (CMEMS-UMINHO), University of Minho, Guimarães, Portugal
| | - Ricardo S Magini
- Postgraduate Program in Dentistry (PPGO), Department of Dentistry, Division of Implant Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| | - Júlio C M Souza
- Center for Microelectromechanical Systems (CMEMS-UMINHO), University of Minho, Guimarães, Portugal
| |
Collapse
|
68
|
Pessanha-Andrade M, Sordi MB, Henriques B, Silva FS, Teughels W, Souza JCM. Custom-made root-analogue zirconia implants: A scoping review on mechanical and biological benefits. J Biomed Mater Res B Appl Biomater 2018; 106:2888-2900. [PMID: 30070423 DOI: 10.1002/jbm.b.34147] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2018] [Revised: 03/18/2018] [Accepted: 04/09/2018] [Indexed: 12/26/2022]
Abstract
The aim of this study was to conduct a literature review on the potential benefits of custom-made root-analogue zirconia implants. A PubMed and ScienceDirect bibliographical search was carried out from 1969 to 2017. The increased interest in zirconia-based dental structures linked to aesthetic and biological outcomes have been reported in literature. Recent technological advances have focused on novel strategies for modification of zirconia-based surfaces to accelerate osseointegration. However, only a few studies revealed mechanical and biological benefits of custom-made root-analogue zirconia implants and therefore further studies should investigate the influence of different design and surface modification on the performance of such implants. Custom-made root-analogue zirconia implants have become a viable alternative to overcome limitations concerning stress distribution, aesthetics, and peri-implantitis induced by biofilms. However, further in vitro and in vivo studies on surface-bone interactions and mechanical behavior of zirconia should be evaluated to reduce clinical issues regarding mechanical failures and late peri-implant bone loss. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 2888-2900, 2018.
Collapse
Affiliation(s)
- Miguel Pessanha-Andrade
- Division of Oral Implantology, School of Dentistry, Universidade Fernando Pessoa (UFP), Porto, Portugal
| | - Mariane B Sordi
- Post-graduate Program in Dentistry (PPGO), Universidade Federal de Santa Catarina (UFSC), Florianópolis, Brazil
| | - Bruno Henriques
- Center for Microelectromechanical Systems (CMEMS-UMinho), University of Minho, Campus Azurém, Guimarães, Portugal
| | - Filipe S Silva
- Center for Microelectromechanical Systems (CMEMS-UMinho), University of Minho, Campus Azurém, Guimarães, Portugal
| | - Wim Teughels
- Department of Oral Health Sciences, University Hospitals Leuven, Katholieke Universiteit Leuven, Leuven, Belgium
| | - Júlio C M Souza
- Center for Microelectromechanical Systems (CMEMS-UMinho), University of Minho, Campus Azurém, Guimarães, Portugal
| |
Collapse
|
69
|
Abstract
PURPOSE OF REVIEW Recently, significant progress has been made in the research related to regenerative medicine. At the same time, biomedical implants in orthopedics and dentistry are facing many challenges and posing clinical concerns. The purpose of this chapter is to provide an overview of the clinical applications of current regenerative strategies to the fields of dentistry and orthopedic surgery. The main research question in this review is: What are the major advancement strategies in regenerative medicine that can be used for implant research? RECENT FINDINGS The implant surfaces can be modified through patient-specific stem cells and plasma coatings, which may provide methods to improve osseointegration and sustainability of the implant. Overall understanding from the review suggesting that the outcome from the studies could lead to identify optimum solutions for many concerns in biomedical implants and even in drug developments as a long-term solution to orthopedic and dental patients.
Collapse
Affiliation(s)
- Divya Rani Bijukumar
- Regenerative Medicine and Disability Research (RMDR) Lab, Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, 1601 Parkview Avenue, Rockford, IL,, 61007, USA
| | - Clay McGeehan
- Regenerative Medicine and Disability Research (RMDR) Lab, Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, 1601 Parkview Avenue, Rockford, IL,, 61007, USA
| | - Mathew T Mathew
- Regenerative Medicine and Disability Research (RMDR) Lab, Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, 1601 Parkview Avenue, Rockford, IL,, 61007, USA.
| |
Collapse
|
70
|
Mystkowska J, Niemirowicz-Laskowska K, Łysik D, Tokajuk G, Dąbrowski JR, Bucki R. The Role of Oral Cavity Biofilm on Metallic Biomaterial Surface Destruction-Corrosion and Friction Aspects. Int J Mol Sci 2018; 19:E743. [PMID: 29509686 PMCID: PMC5877604 DOI: 10.3390/ijms19030743] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Revised: 02/23/2018] [Accepted: 03/03/2018] [Indexed: 12/14/2022] Open
Abstract
Metallic biomaterials in the oral cavity are exposed to many factors such as saliva, bacterial microflora, food, temperature fluctuations, and mechanical forces. Extreme conditions present in the oral cavity affect biomaterial exploitation and significantly reduce its biofunctionality, limiting the time of exploitation stability. We mainly refer to friction, corrosion, and biocorrosion processes. Saliva plays an important role and is responsible for lubrication and biofilm formation as a transporter of nutrients for microorganisms. The presence of metallic elements in the oral cavity may lead to the formation of electro-galvanic cells and, as a result, may induce corrosion. Transitional microorganisms such as sulfate-reducing bacteria may also be present among the metabolic microflora in the oral cavity, which can induce biological corrosion. Microorganisms that form a biofilm locally change the conditions on the surface of biomaterials and contribute to the intensification of the biocorrosion processes. These processes may enhance allergy to metals, inflammation, or cancer development. On the other hand, the presence of saliva and biofilm may significantly reduce friction and wear on enamel as well as on biomaterials. This work summarizes data on the influence of saliva and oral biofilms on the destruction of metallic biomaterials.
Collapse
Affiliation(s)
- Joanna Mystkowska
- Department of Materials Engineering and Production, Faculty of Mechanical Engineering, Bialystok University of Technology, Wiejska 45C, 15-351 Bialystok, Poland.
| | - Katarzyna Niemirowicz-Laskowska
- Department of Microbiological and Nanobiomedical Engineering, Medical University of Bialystok, Mickiewicza 2C, 15-222 Bialystok, Poland.
| | - Dawid Łysik
- Department of Materials Engineering and Production, Faculty of Mechanical Engineering, Bialystok University of Technology, Wiejska 45C, 15-351 Bialystok, Poland.
| | - Grażyna Tokajuk
- Department of Integrated Dentistry, Medical University of Bialystok, M. Sklodowskiej-Curie 24a, 15-276 Bialystok, Poland.
| | - Jan R Dąbrowski
- Department of Materials Engineering and Production, Faculty of Mechanical Engineering, Bialystok University of Technology, Wiejska 45C, 15-351 Bialystok, Poland.
| | - Robert Bucki
- Department of Microbiological and Nanobiomedical Engineering, Medical University of Bialystok, Mickiewicza 2C, 15-222 Bialystok, Poland.
| |
Collapse
|
71
|
Fretwurst T, Nelson K, Tarnow DP, Wang HL, Giannobile WV. Is Metal Particle Release Associated with Peri-implant Bone Destruction? An Emerging Concept. J Dent Res 2017; 97:259-265. [PMID: 29130804 DOI: 10.1177/0022034517740560] [Citation(s) in RCA: 109] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Peri-implant diseases affecting the surrounding structures of endosseous dental implants include peri-implant mucositis and peri-implantitis. The prevalence of peri-implantitis ranges between 15% and 20% after 10 y, highlighting the major challenge in clinical practice in the rehabilitation of dental implant patients. The widespread nature of peri-implant bone loss poses difficulties in the management of biological complications affecting the long-term success of osseointegrated implant reconstructions. Metal and titanium particles have been detected in peri-implant supporting tissues. However, it remains unclear what mechanisms could be responsible for the elicitation of particle and ion release and whether these released implant-associated materials have a local and/or systemic impact on the peri-implant soft and hard tissues. Metal particle release as a potential etiologic factor has been intensively studied in the field of orthopedics and is known to provoke aseptic loosening around arthroplasties and is associated with implant failures. In dental medicine, emerging information about metal/titanium particle release suggests that the potential impact of biomaterials at the abutment or bone interfaces may have an influence on the pathogenesis of peri-implant bone loss. This mini-review highlights current evidence of metal particle release around dental implants and future areas for research.
Collapse
Affiliation(s)
- T Fretwurst
- 1 Department of Periodontics and Oral Medicine, School of Dentistry, University of Michigan, Ann Arbor, MI, USA.,2 Department of Oral and Craniomaxillofacial Surgery, Center for Dental Medicine, University Medical Center Freiburg, Freiburg, Germany
| | - K Nelson
- 2 Department of Oral and Craniomaxillofacial Surgery, Center for Dental Medicine, University Medical Center Freiburg, Freiburg, Germany
| | - D P Tarnow
- 3 College of Dental Medicine, Columbia University, New York, NY, USA
| | - H-L Wang
- 1 Department of Periodontics and Oral Medicine, School of Dentistry, University of Michigan, Ann Arbor, MI, USA
| | - W V Giannobile
- 1 Department of Periodontics and Oral Medicine, School of Dentistry, University of Michigan, Ann Arbor, MI, USA.,4 Department of Biomedical Engineering, College of Engineering, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|