51
|
Roland JT, Gantz BJ, Waltzman SB, Parkinson AJ. Long-term outcomes of cochlear implantation in patients with high-frequency hearing loss. Laryngoscope 2018; 128:1939-1945. [PMID: 29330858 DOI: 10.1002/lary.27073] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2017] [Revised: 10/11/2017] [Accepted: 11/29/2017] [Indexed: 11/07/2022]
Abstract
OBJECTIVE To demonstrate the long-term benefits of implantation in patients with high-frequency sensorineural hearing loss, this report provides 5-year follow-up on a group of implant recipients who were subjects of the Cochlear™ Nucleus® Hybrid™ L24 Implant System pivotal clinical study. METHODS The results of three related clinical studies were compiled to provide outcome data after 1, 3, and 5 years of implant use in a group of subjects who presented with preoperative high-frequency hearing loss and were implanted with a Nucleus Hybrid L24 (Cochlear Ltd., Sydney, Australia) cochlear implant. A subset of the 50 adult subjects (N = 32) who participated in the Hybrid L24 pivotal Investigational Device Exemption (IDE) completed comprehensive evaluations at 12 months postactivation, 3 years postactivation, and then as part of a postapproval study at 5 years postactivation. Testing included audiometric, speech perception, and subjective satisfaction measures. RESULTS Mean unilateral speech perception performance was significantly improved at all postoperative intervals compared to preoperative best-aided results and has remained stable to 5 years postactivation. Ninety-four percent of subjects had measurable hearing, and 72% continued to use electric-acoustic stimulation in the implanted ear after 5 years of implant use. Subjective satisfaction results support objective performance improvements. CONCLUSION Results demonstrate long-term success of patients with high-frequency hearing loss following Hybrid L24 (Cochlear) cochlear implantation. Benefits include speech perception abilities significantly better than those in the preoperative best-aided condition, with additional benefit in those using electric-acoustic stimulation in the implanted ear. LEVEL OF EVIDENCE 2b. Laryngoscope, 1939-1945, 2018.
Collapse
Affiliation(s)
- J Thomas Roland
- Department of Otolaryngology-Head and Neck Surgery, NYU School of Medicine, New York, New York
| | - Bruce J Gantz
- Department of Otolaryngology-Head and Neck Surgery, the University of Iowa, Iowa City, Iowa
| | - Susan B Waltzman
- Department of Otolaryngology-Head and Neck Surgery, NYU School of Medicine, New York, New York
| | | |
Collapse
|
52
|
Abstract
Twenty years ago, cochlear implants (CI) were indicated only in cases of profound hearing loss or complete deafness. While from today's perspective the technology was clumsy and provided patients with only limited speech comprehension in quiet scenarios, successive advances in CI technology and the consequent substantial hearing improvements over time have since then resulted in continuous relaxation of indication criteria toward residual hearing. While achievements in implant and processor electronics have been one key factor for the ever-improving hearing performance, development of electro-acoustic CI systems-together with atraumatic implantation concepts-has led to enormous improvements in patients with low-frequency residual hearing. Manufactures have designed special processors with integrated hearing aid components for this patient group, which are capable of conveying acoustic and electric stimulation. A further milestone in improvement of hearing in challenging listening environments was the adoption of signal enhancement algorithms and assistive listening devices from the hearing aid industry. This article gives an overview of the current state of the art in the abovementioned areas of CI technology.
Collapse
Affiliation(s)
- A Büchner
- Hörzentrum der Medizinischen Hochschule Hannover, Karl-Wiechert-Allee 3, 30625, Hannover, Deutschland.
| | - L Gärtner
- Hörzentrum der Medizinischen Hochschule Hannover, Karl-Wiechert-Allee 3, 30625, Hannover, Deutschland
| |
Collapse
|
53
|
O’Connell BP, Dedmon MM, Haynes DS. Hearing Preservation Cochlear Implantation: a Review of Audiologic Benefits, Surgical Success Rates, and Variables That Impact Success. CURRENT OTORHINOLARYNGOLOGY REPORTS 2017. [DOI: 10.1007/s40136-017-0176-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
54
|
Integration of acoustic and electric hearing is better in the same ear than across ears. Sci Rep 2017; 7:12500. [PMID: 28970567 PMCID: PMC5624923 DOI: 10.1038/s41598-017-12298-3] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2017] [Accepted: 09/06/2017] [Indexed: 11/26/2022] Open
Abstract
Advances in cochlear implant (CI) technology allow for acoustic and electric hearing to be combined within the same ear (electric-acoustic stimulation, or EAS) and/or across ears (bimodal listening). Integration efficiency (IE; the ratio between observed and predicted performance for acoustic-electric hearing) can be used to estimate how well acoustic and electric hearing are combined. The goal of this study was to evaluate factors that affect IE in EAS and bimodal listening. Vowel recognition was measured in normal-hearing subjects listening to simulations of unimodal, EAS, and bimodal listening. The input/output frequency range for acoustic hearing was 0.1–0.6 kHz. For CI simulations, the output frequency range was 1.2–8.0 kHz to simulate a shallow insertion depth and the input frequency range was varied to provide increasing amounts of speech information and tonotopic mismatch. Performance was best when acoustic and electric hearing was combined in the same ear. IE was significantly better for EAS than for bimodal listening; IE was sensitive to tonotopic mismatch for EAS, but not for bimodal listening. These simulation results suggest acoustic and electric hearing may be more effectively and efficiently combined within rather than across ears, and that tonotopic mismatch should be minimized to maximize the benefit of acoustic-electric hearing, especially for EAS.
Collapse
|
55
|
Hearing Preservation During Cochlear Implantation and Electroacoustic Stimulation in Patients With SLC26A4 Mutations. Otol Neurotol 2017; 38:1262-1267. [DOI: 10.1097/mao.0000000000001522] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
56
|
Zanetti D, Nassif N, Redaelli de Zinis LO. Factors affecting residual hearing preservation in cochlear implantation. ACTA OTORHINOLARYNGOLOGICA ITALICA 2017; 35:433-41. [PMID: 26900250 PMCID: PMC4755056 DOI: 10.14639/0392-100x-619] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The likelihood of residual hearing preservation in cochlear implantation (CI) is related to surgical factors such as type of cochleostomy (trans-fenestral vs. promontorial), use of lubricants and protective drugs, and device-related factors such as shape, length and flexibility of the array. We investigated the impact of these factors on the hearing preservation rate in adults and children with conventional audiological indications to CI. Eighty-two children aged 1-9 years and 73 adults (16-79 years) received a CI in the right (59%) or left ear (41%). An anterior-inferior promontorial cochleostomy was performed in 143 ears (92%); a trans-fenestral approach was used in 12 (8%). A perimodiolar electrode was implanted in 144 ears (93%), and a straight electrode in the remaining 11 (7%). Overall, some post-operative hearing was retained in 39% of ears. The rate of preservation was higher at the low than at the high frequencies. When correlated with age, side of implant, implant model and type of cochleostomy, the mean threshold variations did not reach statistical significance for any of these variables. A slight trend in favour of better residual hearing preservation in children vs. adults was seen, especially at lower frequencies.
Collapse
Affiliation(s)
- D Zanetti
- Audiology Department, University of Milano, IRCSS Policlinico "Ca' Granda", Milano, Italy
| | - N Nassif
- Paediatric Otorhinolaryngology Department, University of Brescia, Spedali Civili, Brescia, Italy
| | - L O Redaelli de Zinis
- Paediatric Otorhinolaryngology Department, University of Brescia, Spedali Civili, Brescia, Italy
| |
Collapse
|
57
|
|
58
|
Hybrid cochlear implantation: quality of life, quality of hearing, and working performance compared to patients with conventional unilateral or bilateral cochlear implantation. Eur Arch Otorhinolaryngol 2017; 274:3599-3604. [DOI: 10.1007/s00405-017-4690-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2017] [Accepted: 07/25/2017] [Indexed: 11/27/2022]
|
59
|
Wanna GB, O'Connell BP, Francis DO, Gifford RH, Hunter JB, Holder JT, Bennett ML, Rivas A, Labadie RF, Haynes DS. Predictive factors for short- and long-term hearing preservation in cochlear implantation with conventional-length electrodes. Laryngoscope 2017. [PMID: 28643327 DOI: 10.1002/lary.26714] [Citation(s) in RCA: 67] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVES/HYPOTHESIS The aims of this study were to investigate short- and long-term rates of hearing preservation after cochlear implantation and identify factors that impact hearing preservation. STUDY DESIGN Retrospective review. METHODS Patients undergoing cochlear implantation with conventional-length electrodes and air-conduction thresholds ≤80 dB HL at 250 Hz preoperatively were included. Hearing preservation was defined as air-conduction thresholds ≤80 dB HL at 250 Hz. RESULTS The sample included 196 patients (225 implants). Overall, the rate of short-term hearing preservation was 38% (84/225), with 18% (33/188) of patients preserving hearing long term. Multivariate analysis showed better preoperative hearing was predictive of hearing preservation at short (odds ratio [OR]: 0.93, 95% confidence interval [CI]: 0.91-0.95, P < .001) and long-term follow-up (OR: 0.94, 95% CI: 0.91-0.97, P < .001). Lateral wall electrodes and mid-scala electrodes had 3.4 (95% CI: 1.4-8.6, P = .009) and 5.6-times (95% CI: 1.8-17.3, P = .003) higher odds of hearing preservation than perimodiolar arrays at short-term follow-up, respectively. Long-term data revealed better hearing preservation for lateral wall (OR: 7.6, 95% CI: 1.6-36.1, P = .01), but not mid-scala (OR: 3.1, 95% CI: 0.4-23.1, P = .28), when compared to perimodiolar electrodes. Round window/extended round window (RW/ERW) approaches were associated with higher rates of long-term hearing preservation (21%) than cochleostomy approaches (0%) (P = 0.002) on univariate analysis. CONCLUSIONS Better preoperative residual hearing, lateral wall electrodes, and RW/ERW approaches are predictive of higher rates of long-term functional hearing preservation. LEVEL OF EVIDENCE 4. Laryngoscope, 128:482-489, 2018.
Collapse
Affiliation(s)
- George B Wanna
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Brendan P O'Connell
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - David O Francis
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Rene H Gifford
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Jacob B Hunter
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Jourdan T Holder
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Marc L Bennett
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Alejandro Rivas
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Robert F Labadie
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - David S Haynes
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| |
Collapse
|
60
|
Mirsalehi M, Mohebbi S, Ghajarzadeh M, Lenarz T, Majdani O. Impact of the round window membrane accessibility on hearing preservation in adult cochlear implantation. Eur Arch Otorhinolaryngol 2017; 274:3049-3056. [DOI: 10.1007/s00405-017-4628-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Accepted: 05/30/2017] [Indexed: 10/19/2022]
|
61
|
O'Connell BP, Holder JT, Dwyer RT, Gifford RH, Noble JH, Bennett ML, Rivas A, Wanna GB, Haynes DS, Labadie RF. Intra- and Postoperative Electrocochleography May Be Predictive of Final Electrode Position and Postoperative Hearing Preservation. Front Neurosci 2017; 11:291. [PMID: 28611574 PMCID: PMC5447029 DOI: 10.3389/fnins.2017.00291] [Citation(s) in RCA: 70] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2017] [Accepted: 05/08/2017] [Indexed: 11/13/2022] Open
Abstract
Introduction: The objectives of the current study were to (1) determine the relationship between electrocochleography (ECochG), measured from the cochlear implant (CI) electrode array during and after implantation, and postoperative audiometric thresholds, (2) determine the relationship between ECochG amplitude and electrode scalar location determined by computerized tomography (CT); and (3) determine whether changes in cochlear microphonic (CM) amplitude during electrode insertion were associated with postoperative hearing. Materials and Methods: Eighteen subjects undergoing CI with an Advanced Bionics Mid-Scala device were prospectively studied. ECochG responses were recorded using the implant coupled to a custom signal recording unit. ECochG amplitude collected intraoperatively concurrent with CI insertion and at activation was compared with audiometric thresholds postoperatively. Sixteen patients also underwent postoperative CT to determine scalar location and the relationship to ECochG measures and residual hearing. Results: Mean low-frequency pure tone average (LFPTA) increased following surgery by an average of 28 dB (range 8–50). Threshold elevation was significantly greater for electrodes with scalar dislocation. No correlation was found between intraoperative ECochG and postoperative behavioral thresholds collapsed across frequency; however, mean differences in thresholds measured by intraoperative ECochG and postoperative audiometry were significantly smaller for electrodes inserted completely within scala tympani (ST) vs. those translocating from ST to scala vestibuli. A significant correlation was observed between postoperative ECochG thresholds and behavioral thresholds obtained at activation. Discussion: Postoperative audiometry currently serves as a marker for intracochlear trauma though thresholds are not obtained until device activation or later. When measured at the same time-point postoperatively, low-frequency ECochG thresholds correlated with behavioral thresholds. Intraoperative ECochG thresholds, however, did not correlate significantly with postoperative behavioral thresholds suggesting that changes in cochlear physiology occur between electrode insertion and activation. ECochG may hold clinical utility providing surgeons with feedback regarding insertion trauma due to scalar translocation, which may be predictive of postoperative hearing preservation. Conclusion: CI insertion trauma is generally not evident until postoperative audiometry when loss of residual hearing is confirmed. ECochG has potential to provide estimates of trauma during insertion as well as reliable information regarding degree of hearing preservation.
Collapse
Affiliation(s)
- Brendan P O'Connell
- Department of Otolaryngology, Vanderbilt University Medical CenterNashville, TN, United States
| | - Jourdan T Holder
- Department of Hearing and Speech Sciences, Vanderbilt University Medical CenterNashville, TN, United States
| | - Robert T Dwyer
- Department of Hearing and Speech Sciences, Vanderbilt University Medical CenterNashville, TN, United States
| | - René H Gifford
- Department of Otolaryngology, Vanderbilt University Medical CenterNashville, TN, United States.,Department of Hearing and Speech Sciences, Vanderbilt University Medical CenterNashville, TN, United States
| | - Jack H Noble
- Department of Otolaryngology, Vanderbilt University Medical CenterNashville, TN, United States.,Department of Computer Science and Electrical Engineering, Vanderbilt UniversityNashville, TN, United States
| | - Marc L Bennett
- Department of Otolaryngology, Vanderbilt University Medical CenterNashville, TN, United States
| | - Alejandro Rivas
- Department of Otolaryngology, Vanderbilt University Medical CenterNashville, TN, United States
| | - George B Wanna
- Department of Otolaryngology, Vanderbilt University Medical CenterNashville, TN, United States
| | - David S Haynes
- Department of Otolaryngology, Vanderbilt University Medical CenterNashville, TN, United States
| | - Robert F Labadie
- Department of Otolaryngology, Vanderbilt University Medical CenterNashville, TN, United States.,Department of Computer Science and Electrical Engineering, Vanderbilt UniversityNashville, TN, United States
| |
Collapse
|
62
|
Gantz BJ, Dunn CC, Oleson J, Hansen MR. Acoustic plus electric speech processing: Long-term results. Laryngoscope 2017; 128:473-481. [PMID: 28543270 DOI: 10.1002/lary.26669] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Revised: 03/31/2017] [Accepted: 04/12/2017] [Indexed: 11/09/2022]
Abstract
OBJECTIVE Few studies have investigated the stability of residual hearing and speech perception outcomes in individuals who were implanted with a shorter electrode device. STUDY DESIGN Longitudinal, single-subject design. METHODS Fifty subjects who received a Nucleus Hybrid (Cochlear, Sydney, Australia) short electrode cochlear implant (CI) and had a minimum of 2 years (and up to 15 years) of postoperative longitudinal experience were included in this study. Twenty-three subjects received a Nucleus Hybrid S8 (S8); 14 subjects received a Nucleus Hybrid L24 (L24); and 13 received a Nucleus Hybrid S12 (S12). Audiometric thresholds and consonant-nucleus-consonant (CNC) words were collected pre- and postoperatively for up to 15 years for the S8 subjects and for up to 7 years for the S12 and L24 subjects. AzBio Sentences in multi-talker babble was collected for up to 7 years on the S12 and L24 subjects. RESULTS Longitudinally, 83% of the S8 subjects, 92% of the S12 subjects, and 86% of the L24 subjects maintained a functional hearing pure-tone average (PTA) (125-500 Hz). Predicted change using a piecewise linear mixed model in PTA over time showed a postoperative linear decrease in hearing for each group until 0.5 years, after which the PTA stabilizes and is maintained. The averaged individual data for CNC and AzBio sentences show a significant improvement in scores by 0.25 to 0.5 years postimplantation, after which scores start to reach their maximum. CONCLUSION This long-term study demonstrates that acoustic-electric processing hearing and improvement in speech understanding in quiet and in noise can be accomplished and sustained for many years with a short electrode CI. LEVEL OF EVIDENCE 2C. Laryngoscope, 128:473-481, 2018.
Collapse
Affiliation(s)
- Bruce J Gantz
- Department of Otolaryngology-Head and Neck Surgery, University of Iowa, Iowa City, Iowa, U.S.A
| | - Camille C Dunn
- Department of Otolaryngology-Head and Neck Surgery, University of Iowa, Iowa City, Iowa, U.S.A
| | - Jacob Oleson
- Department of Biostatistics, University of Iowa, Iowa City, Iowa, U.S.A
| | - Marlan R Hansen
- Department of Otolaryngology-Head and Neck Surgery, University of Iowa, Iowa City, Iowa, U.S.A
| |
Collapse
|
63
|
Kim JR, Tejani VD, Abbas PJ, Brown CJ. Intracochlear Recordings of Acoustically and Electrically Evoked Potentials in Nucleus Hybrid L24 Cochlear Implant Users and Their Relationship to Speech Perception. Front Neurosci 2017; 11:216. [PMID: 28469553 PMCID: PMC5395645 DOI: 10.3389/fnins.2017.00216] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2016] [Accepted: 03/30/2017] [Indexed: 11/26/2022] Open
Abstract
The Hybrid cochlear implant (CI) has been developed for individuals with high frequency hearing loss who retain good low frequency hearing. Outcomes have been encouraging but individual variability is high; the health of the cochlea and the auditory nerve may be important factors driving outcomes. Electrically evoked compound action potentials (ECAPs) reflect the response of the auditory nerve to electrical stimulation while electrocochleography (ECochG) reflects the response of the cochlear hair cells and auditory nerve to acoustic stimulation. In this study both ECAPs and ECochG responses were recorded from Nucleus Hybrid L24 CI users. Correlations between these two measures of peripheral auditory function and speech perception are reported. This retrospective study includes data from 25 L24 CI users. ECAPs and ECochG responses were recorded from an intracochlear electrode using stimuli presented at or near maximum acceptable loudness levels. Speech perception was assessed using Consonant-Nucleus-Consonant (CNC) word lists presented in quiet and AzBio sentences presented at a +5 dB signal-to-noise ratio in both the combined acoustic and electric (A+E) and electric (E) alone listening modes. Acoustic gain was calculated by subtracting these two scores. Correlations between these physiologic and speech perception measures were then computed. ECAP amplitudes recorded from the most apical electrode were significantly correlated with CNC scores measured in the E alone (r = 0.56) and A+E conditions (r = 0.64), but not with performance on the AzBio test. ECochG responses recorded using the most apical electrode in the intracochlear array but evoked using a 500 Hz tone burst were not correlated with either the scores on the CNC or AzBio tests. However, ECochG amplitude was correlated with a composite metric relating the additional benefit of acoustic gain in noise relative to quiet conditions (r = 0.67). Both measures can be recorded from Hybrid L24 CI users and both ECAP and ECochG measures may result in more complete characterization of speech perception outcomes than either measure alone.
Collapse
Affiliation(s)
- Jae-Ryong Kim
- Department of Communication Sciences and Disorders, University of IowaIowa City, IA, USA.,Department of Otolaryngology-Head and Neck Surgery, Inje University College of MedicineBusan, South Korea
| | - Viral D Tejani
- Department of Communication Sciences and Disorders, University of IowaIowa City, IA, USA.,Department of Otolaryngology-Head and Neck Surgery, University of Iowa Hospitals and ClinicsIowa City, IA, USA
| | - Paul J Abbas
- Department of Communication Sciences and Disorders, University of IowaIowa City, IA, USA.,Department of Otolaryngology-Head and Neck Surgery, University of Iowa Hospitals and ClinicsIowa City, IA, USA
| | - Carolyn J Brown
- Department of Communication Sciences and Disorders, University of IowaIowa City, IA, USA.,Department of Otolaryngology-Head and Neck Surgery, University of Iowa Hospitals and ClinicsIowa City, IA, USA
| |
Collapse
|
64
|
Schmitt HA, Pich A, Schröder A, Scheper V, Lilli G, Reuter G, Lenarz T. Proteome Analysis of Human Perilymph Using an Intraoperative Sampling Method. J Proteome Res 2017; 16:1911-1923. [DOI: 10.1021/acs.jproteome.6b00986] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Heike A. Schmitt
- Department
of Otolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
- Cluster
of Excellence of the German Research Foundation (DFG; “Deutsche
Forschungsgemeinschaft”) “Hearing4all”, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
| | - Andreas Pich
- Core
Facility Proteomics, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
| | - Anke Schröder
- Core
Facility Proteomics, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
| | - Verena Scheper
- Department
of Otolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
- Cluster
of Excellence of the German Research Foundation (DFG; “Deutsche
Forschungsgemeinschaft”) “Hearing4all”, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
| | - Giorgio Lilli
- Department
of Otolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
- Cluster
of Excellence of the German Research Foundation (DFG; “Deutsche
Forschungsgemeinschaft”) “Hearing4all”, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
| | - Günter Reuter
- Department
of Otolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
- Cluster
of Excellence of the German Research Foundation (DFG; “Deutsche
Forschungsgemeinschaft”) “Hearing4all”, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
| | - Thomas Lenarz
- Department
of Otolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
- Cluster
of Excellence of the German Research Foundation (DFG; “Deutsche
Forschungsgemeinschaft”) “Hearing4all”, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
| |
Collapse
|
65
|
O'Connell BP, Hunter JB, Haynes DS, Holder JT, Dedmon MM, Noble JH, Dawant BM, Wanna GB. Insertion depth impacts speech perception and hearing preservation for lateral wall electrodes. Laryngoscope 2017; 127:2352-2357. [PMID: 28304096 DOI: 10.1002/lary.26467] [Citation(s) in RCA: 122] [Impact Index Per Article: 17.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2016] [Revised: 11/11/2016] [Accepted: 11/22/2016] [Indexed: 11/06/2022]
Abstract
OBJECTIVES 1) Examine angular insertion depths (AID) and scalar location of Med-El (GmbH Innsbruck, Austria) electrodes; and 2) determine the relationship between AID and audiologic outcomes controlling for scalar position. STUDY DESIGN Retrospective review. METHODS Postlingually deafened adults undergoing cochlear implantation with Flex 24, Flex 28, and Standard electrode arrays (Med-El) were identified. Patients with preoperative and postoperative computed tomography scans were included so that electrode location and AID could be determined. Outcome measures were 1) speech perception in the cochlear implant (CI)-only condition, and 2) short-term hearing preservation. RESULTS Forty-eight implants were included; all electrodes (48 of 48) were positioned entirely within the scala tympani. The median AID was 408° (interquartile [IQ] range 373°-449°) for Flex 24, 575° (IQ range 465°-584°) for Flex 28, and 584° (IQ range 368°-643°) for Standard electrodes (Med-El). The mean postoperative CNC score was 43.7% ± 21.9. A positive correlation was observed between greater AID and better CNC performance (r = 0.48, P < 0.001). Excluding patients with postoperative residual hearing, a strong correlation between AID and CNC persisted (r = 0.57, P < 0.001). In patients with preoperative residual hearing, mean low-frequency pure-tone average (PTA) shift was 27 dB ± 14. A correlation between AID and low-frequency PTA shift at activation was noted (r = 0.41, P = 0.04). CONCLUSION Favorable rates of scala tympani insertion (100%) were observed. In the CI-only condition, a direct correlation between greater AID and CNC score was noted regardless of postoperative hearing status. Deeper insertions were, however, associated with worse short-term hearing preservation. When patients without postoperative residual hearing were analyzed independently, the relationship between greater insertion depth and better performance was strengthened. LEVEL OF EVIDENCE 4. Laryngoscope, 127:2352-2357, 2017.
Collapse
Affiliation(s)
- Brendan P O'Connell
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Jacob B Hunter
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - David S Haynes
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Jourdan T Holder
- Department of Hearing and Speech Sciences, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Matt M Dedmon
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Jack H Noble
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Benoit M Dawant
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - George B Wanna
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| |
Collapse
|
66
|
Todt I, Mittmann M, Ernst A, Mittmann P. Comparison of the effects of four different cochlear implant electrodes on intra-cochlear pressure in a model. Acta Otolaryngol 2017; 137:235-241. [PMID: 27661767 DOI: 10.1080/00016489.2016.1232490] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
CONCLUSION Based on this model experiment, a small tip and low volume electrode show lowest intra-cochlear pressure values. Insertional support by a tool minimizes fast pressure changes. Higher electrodes volumes affect slow and fast pressure changes as well. OBJECTIVE Insertion causing low intra-cochlear pressure is assumed to be important for atraumatic cochlear implant surgery to preserve residual hearing. Cochlear implant electrodes differ in terms of parameters like tip size, length, volume, and technique of insertion. The aim of this study was to observe the effect of different cochlear implant electrodes on insertional intra-cochlear pressure in a cochlear model. MATERIALS AND METHODS Cochlear implant electrode insertions were performed in an artificial cochlear model and intra-cochlear pressure changes were recorded in parallel with a micro-pressure sensor positioned in the apical region of the cochlear model to follow the maximum values, temporal changes, maximum amplitude, and frequency of changes in intra-cochlear pressure. Insertions were performed with four different electrodes (Advanced Bionics 1j, Helix, HFMS, and LW23). RESULTS This study found statistically significant differences in the occurrence of initial maximum pressure values correlating with the electrode tip size. The different electrodes and the technique of insertion significantly affected the occurrence of maximum value, amplitude, and frequency of intra-cochlear pressure occurrence.
Collapse
|
67
|
Insertion forces and intracochlear trauma in temporal bone specimens implanted with a straight atraumatic electrode array. Eur Arch Otorhinolaryngol 2017; 274:2131-2140. [PMID: 28238160 DOI: 10.1007/s00405-017-4485-z] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2016] [Accepted: 01/25/2017] [Indexed: 10/20/2022]
Abstract
The aim of the study was to evaluate insertion forces during manual insertion of a straight atraumatic electrode in human temporal bones, and post-implantation histologic evaluation of the samples to determine whether violation of intracochlear structures is related to insertion forces. In order to minimize intracochlear trauma and preserve residual hearing during cochlear implantation, knowledge of the insertion forces is necessary. Ten fresh frozen human temporal bones were prepared with canal wall down mastoidectomy. All samples were mounted on a one-axis force sensor. Insertion of a 16-mm straight atraumatic electrode was performed from different angles to induce "traumatic" insertion. Histologic evaluation was performed in order to evaluate intracochlear trauma. In 4 of 10 samples, dislocation of the electrode into scala vestibuli was observed. The mean insertion force for all 10 procedures was 0.003 ± 0.005 N. Insertion forces measured around the site of dislocation to scala vestibuli in 3 of 4 samples were significantly higher than insertion forces at the same location of the cochleae measured in samples without trauma (p < 0.04). Mean force during the whole insertion process of the straight atraumatic electrode is lower than reported by other studies using longer electrodes. Based on our study, insertion forces leading to basilar membrane trauma may be lower than the previously reported direct rupture forces.
Collapse
|
68
|
Brant JA, Ruckenstein MJ. Electrode selection for hearing preservation in cochlear implantation: A review of the evidence. World J Otorhinolaryngol Head Neck Surg 2016; 2:157-160. [PMID: 29204561 PMCID: PMC5698544 DOI: 10.1016/j.wjorl.2016.08.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2016] [Accepted: 08/10/2016] [Indexed: 11/30/2022] Open
Abstract
Objective To review and assess the ideal length of electrode in cochlear implant patients for hearing preservation. Methods The English language literature was reviewed for studies including hearing preservation and speech understanding for electrodes of different lengths. Results One prospective trial was found, and there were no studies that randomized patients into different length electrodes with an intent to preserve hearing. Eight studies total included multiple length electrodes and contained data regarding hearing preservation. Conclusions Although there is some evidence that indicates that shorter electrodes may improve both short and long-term hearing preservation rates in cochlear implant patients, no study has directly compared implant length on hearing preservation in a similar patient population. A randomized trial of short and standard length electrodes for hearing preservation is warranted. In the interim, utilization of current electrodes measuring 20-25 mm could seem to be a prudent approach when seeking to preserve residual hearing without unduly compromising cochlear coverage.
Collapse
Affiliation(s)
- Jason A Brant
- Department of Otorhinolaryngology-Head and Neck Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Michael J Ruckenstein
- Department of Otorhinolaryngology-Head and Neck Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA 19104, USA
| |
Collapse
|
69
|
Helmstaedter V, Bueltmann E, Lenarz T, Teschner M. Radiologic detectability of the cochlear implant electrode fixation clip using cone beam computed tomography. Cochlear Implants Int 2016; 17:271-275. [DOI: 10.1080/14670100.2016.1248643] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Affiliation(s)
| | - Eva Bueltmann
- Institute of Diagnostic and Interventional Neuroradiology, Hannover Medical School, Germany
| | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School, Germany
| | - Magnus Teschner
- Department of Otolaryngology, Hannover Medical School, Germany
| |
Collapse
|
70
|
Cordero L. IMPLANTE COCLEAR Y AUDICIÓN RESIDUAL. REVISTA MÉDICA CLÍNICA LAS CONDES 2016. [DOI: 10.1016/j.rmclc.2016.11.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
71
|
Hearing Preservation With a Midscalar Electrode Comparison of a Regular and Steroid/Pressure Optimized Surgical Approach in Patients With Residual Hearing. Otol Neurotol 2016; 37:e349-52. [DOI: 10.1097/mao.0000000000001068] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
72
|
Long-term Hearing Preservation Outcomes After Cochlear Implantation for Electric-Acoustic Stimulation. Otol Neurotol 2016; 37:e353-9. [DOI: 10.1097/mao.0000000000001066] [Citation(s) in RCA: 56] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
73
|
The Impact of Electrode Array Length on Hearing Preservation in Cochlear Implantation. Otol Neurotol 2016; 37:1006-15. [DOI: 10.1097/mao.0000000000001110] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
74
|
Scheper V, Leifholz M, von der Leyen H, Keller M, Denkena U, Koch A, Karch A, Miller J, Lenarz T. ACEMg-mediated hearing preservation in cochlear implant patients receiving different electrode lengths (PROHEARING): study protocol for a randomized controlled trial. Trials 2016; 17:394. [PMID: 27502589 PMCID: PMC4977680 DOI: 10.1186/s13063-016-1526-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2015] [Accepted: 07/25/2016] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The indications for a cochlear implant (CI) have been extended to include patients with some residual hearing. Shorter and thinner atraumatic electrodes have been designed to preserve the residual hearing in the implanted ear. However, the insertion of the electrode array into the cochlea, with potential mechanical trauma and the presence of this foreign body inside the cochlea, may lead to free radical formation and reduced blood perfusion of the cochlea which can result in the loss of residual hearing. METHODS/DESIGN In this single-center, randomized, placebo-controlled, double-blind phase II clinical trial the effect of free radical scavengers and a vasodilator on the residual hearing of 140 CI patients will be evaluated. The formulation is composed of β-carotene (vitamin A), ascorbic acid (vitamin C), dl-α-tocopherol acetate (vitamin E) and the vasodilator magnesium (Mg), or ACEMg. Medication is administered twice daily per os for approximately 3 months. The primary measure is based upon the reduction in postoperative low-frequency air-conducted pure-tone thresholds compared to preoperative thresholds in ACEMg-treated patients compared to those of a placebo group. Additionally, the effect of different electrode lengths (20, 24 and 28 mm) is analyzed. Study visits are scheduled 2 days before surgery, at first fitting, which is the adjustment and start of stimulation via CI 4 weeks after surgery and 3, 6, 9 and 12 months after first fitting. The primary endpoint is the air-conduction hearing loss at 500 Hz 3 months after first fitting. Additionally, speech recognition tests, hearing aid benefit in the implanted ear and electrophysiological measurements of implant function are assessed. Since this is a blinded clinical trial and recruitment is still ongoing, data continue to accrue and we cannot yet analyze the outcome of the ACEMg treatment. DISCUSSION There is an unfulfilled need for new strategies to preserve acoustic hearing in CI patients. This study will provide first-in-man data on ACEMg-mediated protection of residual hearing in CI patients. Performing all surgeries and patient follow-up at one study site improves consistency in diagnosis and therapy and less variability in surgery, audiological test techniques and fitting. This approach will allow investigation of the influence of ACEMg on residual hearing in CI patients. TRIAL REGISTRATION The German Bundesinstitut für Arzneimittel und Medizinprodukte (BfArM) application number 4039192, was registered on 6 December 2013 with protocol amendment version 3.0 from 19 August 2014. EudraCT number: 2012-005002-22 .
Collapse
Affiliation(s)
- Verena Scheper
- Department of Otolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany. .,Cluster of Excellence Hearing4all, Hannover and Oldenburg, Germany.
| | - Melanie Leifholz
- Department of Otolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
| | - Heiko von der Leyen
- Hannover Clinical Trial Center, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
| | - Miriam Keller
- Hannover Clinical Trial Center, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
| | - Ute Denkena
- Hannover Clinical Trial Center, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
| | - Armin Koch
- Institute for Biostatistics, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
| | - Annika Karch
- Institute for Biostatistics, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
| | - Josef Miller
- Kresge Hearing Research Institute, University of Michigan, 4605 Medical Science Unit II, Ann Arbor, MI, 48109-5616, USA
| | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.,Cluster of Excellence Hearing4all, Hannover and Oldenburg, Germany
| |
Collapse
|
75
|
Patterns of Long-term Hearing Loss in Hearing Preservation Cochlear Implant Surgery. Otol Neurotol 2016; 37:478-86. [DOI: 10.1097/mao.0000000000001011] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
76
|
Gibson P, Boyd P. Optimal electrode design: Straight versus perimodiolar. Eur Ann Otorhinolaryngol Head Neck Dis 2016; 133 Suppl 1:S63-5. [DOI: 10.1016/j.anorl.2016.04.014] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2016] [Accepted: 04/28/2016] [Indexed: 11/29/2022]
|
77
|
Insertion of Cochlear Implant Electrode Array Using the Underwater Technique for Preserving Residual Hearing. Otol Neurotol 2016; 37:339-44. [DOI: 10.1097/mao.0000000000000989] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
78
|
Hunter JB, Carlson ML, Glasscock ME. The ototronix MAXUM middle ear implant for severe high-frequency sensorineural hearing loss: Preliminary results. Laryngoscope 2016; 126:2124-7. [PMID: 26972428 DOI: 10.1002/lary.25872] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2015] [Revised: 11/05/2015] [Accepted: 12/10/2015] [Indexed: 11/09/2022]
Abstract
OBJECTIVES/HYPOTHESIS To report the preliminary results of the Ototronix MAXUM middle ear implant for treatment of severe high-frequency sensorineural hearing loss. STUDY DESIGN Case series with chart review. METHODS Six consecutive ears with severe high-frequency sensorineural hearing loss (≥75 dB HL at 2, 3, and 4 kHz) and poor aided word recognition performance (≤60% single words) underwent implantation of the MAXUM system at a single, private otologic referral center. Primary outcome measures included frequency-specific functional gain and word recognition score improvement compared to optimally fitted hearing aids. RESULTS Six ears, in four adult patients (two female; median age 67.5 years) were included. The median unaided preoperative high-frequency pure-tone average (HFPTA) (2, 3, and 4 kHz) was 80.0 dB (range, 75.0-85.0 dB), and the median best-aided word recognition score was 48.0% (range, 24%-60%). The median HFPTA functional gain with the MAXUM system was 47.2 dB, a 25.0 dB improvement (range, 16.7-33.3 dB) (P = .03) over optimally fit hearing aids, and the median word recognition score with MAXUM was 81.5%, a 42.0% improvement (range, 20%-48%) (P = .03) with the MAXUM middle ear implant over optimally fitted hearing aids. CONCLUSIONS These preliminary data demonstrate that the MAXUM middle ear implant provides superior functional gain and word recognition scores in quiet for patients with severe high-frequency sensorineural hearing loss compared to optimally fitted hearing aids. Future studies with greater patient numbers and patient reported outcome measures are needed to confirm these promising but preliminary results. LEVEL OF EVIDENCE 4 Laryngoscope, 126:2124-2127, 2016.
Collapse
Affiliation(s)
- Jacob B Hunter
- Otology Group of Vanderbilt University, Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Matthew L Carlson
- Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic School of Medicine, Rochester, Minnesota, U.S.A
| | - Michael E Glasscock
- Otology Group of Vanderbilt University, Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| |
Collapse
|
79
|
Insertion trauma of a cochlear implant electrode array with Nitinol inlay. Eur Arch Otorhinolaryngol 2016; 273:3573-3585. [PMID: 26961519 DOI: 10.1007/s00405-016-3955-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2015] [Accepted: 02/26/2016] [Indexed: 10/22/2022]
Abstract
The integration of a shape memory actuator is a potential mechanism to achieve a consistent perimodiolar position after electrode insertion during cochlear implant surgery. After warming up, and therefore activation of the shape memory effect, the electrode array will change from a straight configuration into a spiral shaped one leading to a final position close to the modiolus. The aim of this study was to investigate whether the integration of an additional thin wire (referred to as an "inlay") made of Nitinol, a well-established shape memory alloy, in a conventional hearing preservation electrode array will affect the insertion behaviour in terms of increased risk of insertion trauma. Six conventional Hybrid-L electrode arrays (Cochlear Ltd., Sydney, Australia) were modified to incorporate a wire inlay made of Nitinol. The diameter of the wires was 100 µm with a tapered tip region. Electrodes were inserted into human temporal bone specimens using a standard surgical approach. After insertion and embedding in epoxy resin, histological sections were prepared to evaluate insertion trauma. Insertion was straightforward and no difficulties were observed. The addition of a shape memory wire, thin but also strong enough to curl the electrode array, does not result in histologically detectable insertion trauma. Atraumatic insertion seems possible.
Collapse
|
80
|
Hunter JB, Gifford RH, Wanna GB, Labadie RF, Bennett ML, Haynes DS, Rivas A. Hearing Preservation Outcomes With a Mid-Scala Electrode in Cochlear Implantation. Otol Neurotol 2016; 37:235-40. [PMID: 26825671 PMCID: PMC7185162 DOI: 10.1097/mao.0000000000000963] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To evaluate hearing preservation (HP) outcomes in adult cochlear implant recipients with a mid-scala electrode. SETTING Tertiary academic center. PATIENTS Adult patients implanted with a mid-scala electrode between May 2013 and July 2015. INTERVENTIONS Cochlear implantation. MAIN OUTCOME MEASURE(S) Age, sex, surgical approach, residual hearing changes post cochlear implantation, HP rates using different published classifications, and speech perception scores. RESULTS Fifty ears for 47 patients (mean age, 58.2 yr; range, 23-86) were implanted with the electrode. Recognizing that not all patients were true HP candidates and/or underwent generally accepted HP surgical techniques, 39 ears had preoperative low-frequency hearing (audiometric threshold ≤ 85dB HL at 250Hz), 24 preserved acoustic hearing postoperatively (75.0%). Patients who had preserved acoustic hearing were implanted via round window (N = 18), extended round window (N = 4), or via cochleostomy (N = 2) approaches. Mean threshold elevation for low-frequency pure-tone average (125, 250, and 500 Hz) was 20.2 dB after surgery. 43.8% of patients had aidable low-frequency hearing at activation, 30.0% at 6-months postoperatively, and 30.8% 1-year postopera tively. Using a formula outlined by Skarzynski and colleagues, at 6-months postoperatively, 15.0% of patients had complete HP, whereas 40.0% had partial HP. At 1-year, these percentages decreased to 0% and 38.5%, respectively. Age, type of approach, and perioperative steroid use were not correlated with HP outcomes at activation and 6-months postoperatively (p > 0.05). CONCLUSION The mid-scala electrode evaluated allows preservation of low-frequency hearing in patients undergoing cochlear implantation at rates and degrees of preservation close to other reports in the cochlear implant literature.
Collapse
Affiliation(s)
- Jacob B Hunter
- The Otology Group of Vanderbilt University, Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | | | | | | | | | | | | |
Collapse
|
81
|
Bento RF, Danieli F, Magalhães ATDM, Gnansia D, Hoen M. Residual Hearing Preservation with the Evo® Cochlear Implant Electrode Array: Preliminary Results. Int Arch Otorhinolaryngol 2016; 20:353-358. [PMID: 27746839 PMCID: PMC5063727 DOI: 10.1055/s-0036-1572530] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2015] [Accepted: 11/15/2015] [Indexed: 10/25/2022] Open
Abstract
Introduction The preservation of residual hearing is currently an important challenge for cochlear implant surgeries. Indeed, if patients exhibit functional hearing after cochlear implantation, they can benefit from the combination of acoustical stimulation, usually in the low-frequencies and electrical stimulation in the high-frequencies. This combined mode of stimulation has proven to be beneficial both in terms of speech perception and of sound quality. Finding the right procedures for conducting soft-surgeries and designing electrode arrays dedicated to hearing preservation is an open issue. Objective The objective of this study is to evaluate the combination of a soft-surgery procedure implicating round-window insertion and the use of dexamethasone and hyaluronic acid during surgery, with the use of a specifically designed straight soft electrode array, on hearing preservation in patients with functional hearing in the low frequencies. Methods This pre-clinical trial was conducted on seven patients with residual hearing in the low frequencies. The surgical method used employed a round window insertion and the use of topical dexamethasone. Results The soft-surgery protocol could be successfully followed in five patients. In this group, the average hearing threshold shift compared with pre-operative values was of 18.7 +/- 16.1 dB HL up to 500 Hz and 15.7 +/- 15.1 up to 1 kHz, demonstrating satisfying levels of hearing preservation. Conclusion We were able to demonstrate the possibility of preserving residual hearing in most of the patients using the EVO electrode. Significant residual hearing preservation levels were was obtained when a soft surgical approach involving round window insertion, dexamethasone and hyaluronic use during the surgery.
Collapse
Affiliation(s)
| | | | | | - Dan Gnansia
- Department of Scientific and Clinical Research, Oticon Medical, Vallauris, France
| | - Michel Hoen
- Department of Scientific and Clinical Research, Oticon Medical, Vallauris, France
| |
Collapse
|
82
|
Abstract
INTRODUCTION Electro-acoustic stimulation (EAS) of the cochlea uses the preserved residual low-frequency hearing for acoustic stimulation in combination with electrical stimulation. The acoustic low-frequency component is amplified and high-frequency hearing is enhanced by a cochlear implant (CI). In this work, the feasibility of EAS by the floating mass transducers (FMTs) firmly attached to the implanted electrode was investigated and the achieved stapes displacement was compared with sound stimulation. METHODS Experiments were performed in eight fresh human temporal bones compliant to the ASTM standard (F2504-5). Four EAS custom-made prototypes (EAS-CMP) were tested, consisting of standard MED-EL CI electrodes with Vibrant Soundbridge (VSB) FMTs or a Bonebridge (BB) FMT tightly molded to the electrode in different orientations. The stapes footplate (SFP) response to EAS-CMP stimulation and sound stimulation was measured using a Laser Doppler Vibrometer (LDV). RESULTS The SFP displacement amplitudes achieved by EAS-CMP stimulation were calculated to 1 VRMS FMT input and were pair-wise statistically compared between prototypes yielding no significant differences at frequencies ≤1 kHz. At frequencies ≤1 kHz stimulation by the BB FMT resulted in a flat and potentially highest SFP displacement amplitude of approximately -40 dB re μm at 1 VRMS input voltage. Estimated equivalent sound pressure levels achieved by the BB FMT prototype were approximately 83-90 eq. dB SPL at frequencies ≤1 kHz. CONCLUSION The feasibility of cochlear stimulation by vibrating electrodes was shown although the achieved output level at frequencies ≤1 kHz was too low for EAS applications.
Collapse
|
83
|
Vila PM, Hullar TE, Buchman CA, Lieu JEC. Is There a Need for Performance Measures for Cochlear Implant Centers? Otolaryngol Head Neck Surg 2015; 153:484-7. [PMID: 25805636 PMCID: PMC9135506 DOI: 10.1177/0194599815575006] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2014] [Accepted: 02/06/2015] [Indexed: 11/15/2022]
Abstract
Performance measures (PMs), or quality indicators, are metrics based on objective data that allow one to assess whether a system achieves a prespecified goal. Given the relatively high level of resource utilization and potential morbidity associated with cochlear implantation (CI), PMs could be used to evaluate quality of care provided by implant centers and, ultimately, optimize care delivery. This article discusses PMs currently in use, how PMs are developed, potential downsides of using PMs, and various examples of PMs that could be used in CI centers.
Collapse
Affiliation(s)
- Peter M Vila
- Department of Otolaryngology-Head & Neck Surgery, Washington University School of Medicine, St Louis, Missouri, USA
| | - Timothy E Hullar
- Department of Otolaryngology-Head & Neck Surgery, Oregon Health and Science University, Portland, Oregon, USA
| | - Craig A Buchman
- Department of Otolaryngology-Head & Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | - Judith E C Lieu
- Department of Otolaryngology-Head & Neck Surgery, Washington University School of Medicine, St Louis, Missouri, USA
| |
Collapse
|
84
|
Individual Optimization of the Insertion of a Preformed Cochlear Implant Electrode Array. Int J Otolaryngol 2015; 2015:724703. [PMID: 26448764 PMCID: PMC4581552 DOI: 10.1155/2015/724703] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2015] [Accepted: 08/06/2015] [Indexed: 11/21/2022] Open
Abstract
Purpose. The aim of this study was to show that individual adjustment of the curling behaviour of a preformed cochlear implant (CI) electrode array to the patient-specific shape of the cochlea can improve the insertion process in terms of reduced risk of insertion trauma. Methods. Geometry and curling behaviour of preformed, commercially available electrode arrays were modelled. Additionally, the anatomy of each small, medium-sized, and large human cochlea was modelled to consider anatomical variations. Finally, using a custom-made simulation tool, three different insertion strategies (conventional Advanced Off-Stylet (AOS) insertion technique, an automated implementation of the AOS technique, and a manually optimized insertion process) were simulated and compared with respect to the risk of insertion-related trauma. The risk of trauma was evaluated using a newly developed “trauma risk” rating scale. Results. Using this simulation-based approach, it was shown that an individually optimized insertion procedure is advantageous compared with the AOS insertion technique. Conclusion. This finding leads to the conclusion that, in general, consideration of the specific curling behaviour of a CI electrode array is beneficial in terms of less traumatic insertion. Therefore, these results highlight an entirely novel aspect of clinical application of preformed perimodiolar electrode arrays in general.
Collapse
|
85
|
Beiter AL, Nel E. The history of Cochlear™ Nucleus ® sound processor upgrades: 30 years and counting. J Otol 2015; 10:108-114. [PMID: 29937792 PMCID: PMC6002568 DOI: 10.1016/j.joto.2015.10.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2015] [Revised: 10/08/2015] [Accepted: 10/13/2015] [Indexed: 11/29/2022] Open
Abstract
To review developments in sound processors over the past 30 years that have resulted in significant improvements in outcomes for Nucleus® recipients.
Collapse
Affiliation(s)
- Anne L Beiter
- Cochlear Limited, 1 University Avenue, Macquarie University, Sydney, NSW 2109, Australia
| | - Esti Nel
- Cochlear Limited, 1 University Avenue, Macquarie University, Sydney, NSW 2109, Australia
| |
Collapse
|
86
|
Braun K, Zenner HP, Friese N, Tropitzsch A. [Differential indication of active middle ear implants]. HNO 2015; 63:402-18. [PMID: 26054730 DOI: 10.1007/s00106-015-0018-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
INTRODUCTION Hearing aids (HA) provide adequate support for many patients with hearing loss, but not all. Around one third of 10.000 patients provided with hearing aids in the Abbreviated Profile of Hearing Aid Benefit felt no actual benefit when using the hearing aid, although they demonstrated the necessary hearing improvement on speech audiometry. Epidemiological data show bad compliance, especially in older people. Only one in three hearing aid owners wears their device regularly. For this subpopulation of patients active middle ear implants (AMEIs) have been used since 1998. In the present review, the current indications for AMEIs are presented. MATERIAL AND METHODS A selective literature search in PubMed, as well as a guideline search at the Arbeitsgemeinschaft der Wissenschaftlichen Fachgesellschaften e. V. (German Association of Scientific Societies), was carried out. RESULTS The present review shows that when there is an adequate indication the hearing capacity of patients can be thoroughly rehabilitated and thus their quality of life improved with the help of AMEIs. Although most commercially available systems have a satisfactory risk profile, increased extrusion rates, malfunctioning and facial paresis have been reported in older implant series. The advantages of AMEIs include increased hearing gain, reduced feedback, increased hearing quality, increased speech discrimination in the presence of background noise, and an absence of occlusion. CONCLUSIONS The audiological indication for AMEIs in primary care is usually controversial, since the functional hearing gain and increase in speech discrimination may be small compared with modern conventional hearing aids. AMEIs thus play a main role in the secondary care of patients who do not have sufficient benefit or who have side effects after having a conventional hearing aid fitted.
Collapse
Affiliation(s)
- K Braun
- Kopf-Hals-Chirurgie, Plastische Operationen, Universitätsklinik für Hals-Nasen-Ohren-Heilkunde, Elfriede-Aulhorn-Str. 5, 72076, Tübingen, Deutschland,
| | | | | | | |
Collapse
|