51
|
Chen J, Ahn T, Colón-Bernal ID, Kim J, Banaszak Holl MM. The Relationship of Collagen Structural and Compositional Heterogeneity to Tissue Mechanical Properties: A Chemical Perspective. ACS NANO 2017; 11:10665-10671. [PMID: 29112404 DOI: 10.1021/acsnano.7b06826] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Collagen is the primary protein component in mammalian connective tissues. Over the last 20 years, evidence has mounted that collagen matrices exhibit substantial heterogeneity in their hierarchical structures and that this heterogeneity plays important roles in both structure and function. Herein, an overview of studies addressing the nanoscale compositional and structural heterogeneity is provided and connected to work exploring the mechanical implications for a number of tissues.
Collapse
Affiliation(s)
- Junjie Chen
- Department of Chemistry, ‡Macromolecular Science and Engineering, and §Department of Biomedical Engineering, University of Michigan , Ann Arbor, Michigan 48109, United States
| | - Taeyong Ahn
- Department of Chemistry, ‡Macromolecular Science and Engineering, and §Department of Biomedical Engineering, University of Michigan , Ann Arbor, Michigan 48109, United States
| | - Isabel D Colón-Bernal
- Department of Chemistry, ‡Macromolecular Science and Engineering, and §Department of Biomedical Engineering, University of Michigan , Ann Arbor, Michigan 48109, United States
| | - Jinhee Kim
- Department of Chemistry, ‡Macromolecular Science and Engineering, and §Department of Biomedical Engineering, University of Michigan , Ann Arbor, Michigan 48109, United States
| | - Mark M Banaszak Holl
- Department of Chemistry, ‡Macromolecular Science and Engineering, and §Department of Biomedical Engineering, University of Michigan , Ann Arbor, Michigan 48109, United States
| |
Collapse
|
52
|
Modeling the effect of collagen fibril alignment on ligament mechanical behavior. Biomech Model Mechanobiol 2017; 17:543-557. [PMID: 29177933 DOI: 10.1007/s10237-017-0977-4] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2017] [Accepted: 10/30/2017] [Indexed: 01/08/2023]
Abstract
Ligament mechanical behavior is primarily regulated by fibrous networks of type I collagen. Although these fibrous networks are typically highly aligned, healthy and injured ligament can also exhibit disorganized collagen architecture. The objective of this study was to determine whether variations in the collagen fibril network between neighboring ligaments can predict observed differences in mechanical behavior. Ligament specimens from two regions of bovine fetlock joints, which either exhibited highly aligned or disorganized collagen fibril networks, were mechanically tested in uniaxial tension. Confocal microscopy and FiberFit software were used to quantify the collagen fibril dispersion and mean fibril orientation in the mechanically tested specimens. These two structural parameters served as inputs into an established hyperelastic constitutive model that accounts for a continuous distribution of planar fibril orientations. The ability of the model to predict differences in the mechanical behavior between neighboring ligaments was tested by (1) curve fitting the model parameters to the stress response of the ligament with highly aligned fibrils and then (2) using this model to predict the stress response of the ligament with disorganized fibrils by only changing the parameter values for fibril dispersion and mean fibril orientation. This study found that when using parameter values for fibril dispersion and mean fibril orientation based on confocal imaging data, the model strongly predicted the average stress response of ligaments with disorganized fibrils ([Formula: see text]); however, the model only successfully predicted the individual stress response of ligaments with disorganized fibrils in half the specimens tested. Model predictions became worse when parameters for fibril dispersion and mean fibril orientation were not based on confocal imaging data. These findings emphasize the importance of collagen fibril alignment in ligament mechanics and help advance a mechanistic understanding of fibrillar networks in healthy and injured ligament.
Collapse
|
53
|
Buchanan KA, Lakes RS, Vanderby R. Chiral behavior in rat tail tendon fascicles. J Biomech 2017; 64:206-211. [DOI: 10.1016/j.jbiomech.2017.09.034] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2017] [Revised: 09/16/2017] [Accepted: 09/25/2017] [Indexed: 11/28/2022]
|
54
|
Snedeker JG, Foolen J. Tendon injury and repair - A perspective on the basic mechanisms of tendon disease and future clinical therapy. Acta Biomater 2017; 63:18-36. [PMID: 28867648 DOI: 10.1016/j.actbio.2017.08.032] [Citation(s) in RCA: 199] [Impact Index Per Article: 28.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Revised: 08/16/2017] [Accepted: 08/25/2017] [Indexed: 12/16/2022]
Abstract
Tendon is an intricately organized connective tissue that efficiently transfers muscle force to the bony skeleton. Its structure, function, and physiology reflect the extreme, repetitive mechanical stresses that tendon tissues bear. These mechanical demands also lie beneath high clinical rates of tendon disorders, and present daunting challenges for clinical treatment of these ailments. This article aims to provide perspective on the most urgent frontiers of tendon research and therapeutic development. We start by broadly introducing essential elements of current understanding about tendon structure, function, physiology, damage, and repair. We then introduce and describe a novel paradigm explaining tendon disease progression from initial accumulation of damage in the tendon core to eventual vascular recruitment from the surrounding synovial tissues. We conclude with a perspective on the important role that biomaterials will play in translating research discoveries to the patient. STATEMENT OF SIGNIFICANCE Tendon and ligament problems represent the most frequent musculoskeletal complaints for which patients seek medical attention. Current therapeutic options for addressing tendon disorders are often ineffective, and the need for improved understanding of tendon physiology is urgent. This perspective article summarizes essential elements of our current knowledge on tendon structure, function, physiology, damage, and repair. It also describes a novel framework to understand tendon physiology and pathophysiology that may be useful in pushing the field forward.
Collapse
|
55
|
Wardle R, Pullman JA, Haldenby S, Ressel L, Pope M, Clegg PD, Radford A, Stewart JP, Al-Saadi M, Dyer P, Peffers MJ. Identification of Equid herpesvirus 2 in tissue-engineered equine tendon. Wellcome Open Res 2017; 2:60. [PMID: 29152595 PMCID: PMC5664983 DOI: 10.12688/wellcomeopenres.12176.2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/28/2017] [Indexed: 01/03/2023] Open
Abstract
Background: Incidental findings of virus-like particles were identified following electron microscopy of tissue-engineered tendon constructs (TETC) derived from equine tenocytes. We set out to determine the nature of these particles, as there are few studies which identify virus in tendons
per se, and their presence could have implications for tissue-engineering using allogenic grafts. Methods: Virus particles were identified in electron microscopy of TETCs. Virion morphology was used to initially hypothesise the virus identity. Next generation sequencing was implemented to identify the virus. A pan herpesvirus PCR was used to validate the RNASeq findings using an independent platform. Histological analysis and biochemical analysis was undertaken on the TETCs. Results: Morphological features suggested the virus to be either a retrovirus or herpesvirus. Subsequent next generation sequencing mapped reads to Equid herpesvirus 2 (EHV2). Histological examination and biochemical testing for collagen content revealed no significant differences between virally affected TETCs and non-affected TETCs. An independent set of equine superficial digital flexor tendon tissue (n=10) examined using designed primers for specific EHV2 contigs identified at sequencing were negative. These data suggest that EHV is resident in some equine tendon. Conclusions: EHV2 was demonstrated in equine tenocytes for the first time; likely from
in vivo infection. The presence of EHV2 could have implications to both tissue-engineering and tendinopathy.
Collapse
Affiliation(s)
- Roisin Wardle
- Institute of Veterinary Science, University of Liverpool, Leahurst Campus, Chester High Road, Neston, Wirral, UK
| | - Jane A Pullman
- Centre for Genomic Research, Institute of Integrative Biology, University of Liverpool, Biosciences Building, Crown Street, Liverpool, UK
| | - Sam Haldenby
- Centre for Genomic Research, Institute of Integrative Biology, University of Liverpool, Biosciences Building, Crown Street, Liverpool, UK
| | - Lorenzo Ressel
- Institute of Veterinary Science, University of Liverpool, Leahurst Campus, Chester High Road, Neston, Wirral, UK
| | - Marion Pope
- Institute of Veterinary Science, University of Liverpool, Leahurst Campus, Chester High Road, Neston, Wirral, UK
| | - Peter D Clegg
- Institute of Ageing and Chronic Disease, University of Liverpool, William Henry Duncan Building, West Derby Street, Liverpool, UK
| | - Alan Radford
- Institute of Infection and Global Health, Department of Infection Biology, University of Liverpool, West Derby Street, Liverpool , UK
| | - James P Stewart
- Institute of Infection and Global Health, Department of Infection Biology, University of Liverpool, West Derby Street, Liverpool , UK
| | - Mohammed Al-Saadi
- Institute of Infection and Global Health, Department of Infection Biology, University of Liverpool, West Derby Street, Liverpool , UK
| | - Philip Dyer
- Institute of Veterinary Science, University of Liverpool, Leahurst Campus, Chester High Road, Neston, Wirral, UK
| | - Mandy J Peffers
- Institute of Ageing and Chronic Disease, University of Liverpool, William Henry Duncan Building, West Derby Street, Liverpool, UK
| |
Collapse
|
56
|
Szczesny SE, Fetchko KL, Dodge GR, Elliott DM. Evidence that interfibrillar load transfer in tendon is supported by small diameter fibrils and not extrafibrillar tissue components. J Orthop Res 2017; 35:2127-2134. [PMID: 28071819 PMCID: PMC5503823 DOI: 10.1002/jor.23517] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2016] [Accepted: 01/06/2017] [Indexed: 02/06/2023]
Abstract
Collagen fibrils in tendon are believed to be discontinuous and transfer tensile loads through shear forces generated during interfibrillar sliding. However, the structures that transmit these interfibrillar forces are unknown. Various extrafibrillar tissue components (e.g., glycosaminoglycans, collagens XII and XIV) have been suggested to transmit interfibrillar loads by bridging collagen fibrils. Alternatively, collagen fibrils may interact directly through physical fusions and interfibrillar branching. The objective of this study was to test whether extrafibrillar proteins are necessary to transmit load between collagen fibrils or if interfibrillar load transfer is accomplished directly by the fibrils themselves. Trypsin digestions were used to remove a broad spectrum of extrafibrillar proteins and measure their contribution to the multiscale mechanics of rat tail tendon fascicles. Additionally, images obtained from serial block-face scanning electron microscopy were used to determine the three-dimensional fibrillar organization in tendon fascicles and identify any potential interfibrillar interactions. While trypsin successfully removed several extrafibrillar tissue components, there was no change in the macroscale fascicle mechanics or fibril:tissue strain ratio. Furthermore, the imaging data suggested that a network of smaller diameter fibrils (<150 nm) wind around and fuse with their neighboring larger diameter fibrils. These findings demonstrate that interfibrillar load transfer is not supported by extrafibrillar tissue components and support the hypothesis that collagen fibrils are capable of transmitting loads themselves. Conclusively determining how fibrils bear load within tendon is critical for identifying the mechanisms that impair tissue function with degeneration and for restoring tissue properties via cell-mediated regeneration or engineered tissue replacements. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2127-2134, 2017.
Collapse
Affiliation(s)
- Spencer E. Szczesny
- Department of Bioengineering, University of Pennsylvania, 240 Skirkanich Hall, 210 South 33rd St, Philadelphia, PA 19104
| | - Kristen L. Fetchko
- Department of Biomedical Engineering, University of Delaware, 161 Colburn Lab, 150 Academy Street, Newark, DE 19716
| | - George R. Dodge
- Department of Orthopaedic Surgery, University of Pennsylvania, 424 Stemmler Hall, 36 St & Hamilton Walk, Philadelphia, PA 19104,Translational Musculoskeletal Research Center, Corporal Michael J. Crescenz Veterans Affairs Medical Center, 3900 Woodland Ave, Philadelphia, PA 19104
| | - Dawn M. Elliott
- Department of Biomedical Engineering, University of Delaware, 161 Colburn Lab, 150 Academy Street, Newark, DE 19716,Corresponding Author: Dawn M. Elliott, Ph.D., 161 Colburn Lab, 150 Academy Street, Newark, DE 19716, Phone: 302-831-1295,
| |
Collapse
|
57
|
Bordvik DH, Haslerud S, Naterstad IF, Lopes-Martins RAB, Leal Junior ECP, Bjordal JM, Joensen J. Penetration Time Profiles for Two Class 3B Lasers inIn SituHuman Achilles at Rest and Stretched. Photomed Laser Surg 2017; 35:546-554. [DOI: 10.1089/pho.2016.4257] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Affiliation(s)
- Daniel Huseby Bordvik
- NorPhyPain Research Group, Faculty of Health and Social Sciences, Centre for Evidence Based Practice, Bergen University College, Bergen, Norway
- Physiotherapy Research Group, Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway
- Haugesund Rheumatological Hospital, Rehabilitation West A/S, Haugesund, Norway
| | - Sturla Haslerud
- NorPhyPain Research Group, Faculty of Health and Social Sciences, Centre for Evidence Based Practice, Bergen University College, Bergen, Norway
- Physiotherapy Research Group, Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway
| | - Ingvill Fjell Naterstad
- NorPhyPain Research Group, Faculty of Health and Social Sciences, Centre for Evidence Based Practice, Bergen University College, Bergen, Norway
- Physiotherapy Research Group, Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway
| | - Rodrigo Alvaro Brandão Lopes-Martins
- Nucleous of Technological Research—NPT, Post-Graduate Program in Biomedical Engineering, University of Mogi das Cruzes (UMC), Mogi das Cruzes, São Paulo, Brazil
| | | | - Jan Magnus Bjordal
- NorPhyPain Research Group, Faculty of Health and Social Sciences, Centre for Evidence Based Practice, Bergen University College, Bergen, Norway
- Physiotherapy Research Group, Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway
- Department of Occupational Therapy, Physiotherapy and Radiography, Bergen University College, Bergen, Norway
| | - Jon Joensen
- NorPhyPain Research Group, Faculty of Health and Social Sciences, Centre for Evidence Based Practice, Bergen University College, Bergen, Norway
- Physiotherapy Research Group, Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway
- Department of Occupational Therapy, Physiotherapy and Radiography, Bergen University College, Bergen, Norway
| |
Collapse
|
58
|
Wardle R, Pullman JA, Haldenby S, Ressel L, Pope M, Clegg PD, Radford A, Stewart JP, Al-Saadi M, Dyer P, Peffers MJ. Identification of Equid herpesvirus 2 in tissue-engineered equine tendon. Wellcome Open Res 2017. [DOI: 10.12688/wellcomeopenres.12176.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Background:Incidental findings of virus-like particles were identified following electron microscopy of tissue-engineered tendon constructs (TETC) derived from equine tenocytes. We set out to determine the nature of these particles, as there are few studies which identify virus in tendonsper se, and their presence could have implications for tissue-engineering using allogenic grafts.Methods:Virus particles were identified in electron microscopy of TETCs. Virion morphology was used to initially hypothesise the virus identity. Next generation sequencing was implemented to identify the virus. A pan herpesvirus PCR was used to validate the RNASeq findings using an independent platform. Histological analysis and biochemical analysis was undertaken on the TETCs.Results:Morphological features suggested the virus to be either a retrovirus or herpesvirus. Subsequent next generation sequencing mapped reads to Equid herpesvirus 2 (EHV2). Histological examination and biochemical testing for collagen content revealed no significant differences between virally affected TETCs and non-affected TETCs. An independent set of equine superficial digital flexor tendon tissue (n=10) examined using designed primers for specific EHV2 contigs identified at sequencing were negative. These data suggest that EHV is resident in some equine tendon.Conclusions:EHV2 was demonstrated in equine tenocytes for the first time; likely fromin vivoinfection. The presence of EHV2 could have implications to both tissue-engineering and tendinopathy.
Collapse
|
59
|
Affiliation(s)
- Gang Seob Jung
- Laboratory for Atomistic and Molecular Mechanics, Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139
| | - Markus J. Buehler
- Laboratory for Atomistic and Molecular Mechanics, Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139
| |
Collapse
|
60
|
Patel D, Sharma S, Bryant SJ, Screen HRC. Recapitulating the Micromechanical Behavior of Tension and Shear in a Biomimetic Hydrogel for Controlling Tenocyte Response. Adv Healthc Mater 2017; 6. [PMID: 28026126 PMCID: PMC5469035 DOI: 10.1002/adhm.201601095] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2016] [Revised: 11/21/2016] [Indexed: 12/11/2022]
Abstract
A fiber composite system is presented which recapitulates the fiber-composite-like nature of tissues and generates similar modes of shear and tension. The shear/tension ratio can be customized during composite manufacture and incorporates viable cells. The system is a valuable tool for mechanotransduction research, providing a platform with physiologically relevant conditions for investigating cell behavior in different tissue types.
Collapse
Affiliation(s)
- Dharmesh Patel
- School of Engineering and Materials Science; Queen Mary University of London; Mile End Road London E1 4NS UK
| | - Sadhana Sharma
- Department of Chemical and Biological Engineering; University of Colorado Boulder; Boulder CO 80303 USA
| | - Stephanie J. Bryant
- Department of Chemical and Biological Engineering; Material Science and Engineering Program; BioFrontiers Institute; University of Colorado; Boulder CO 80303 USA
| | - Hazel R. C. Screen
- School of Engineering and Materials Science; Queen Mary University of London; Mile End Road London E1 4NS UK
| |
Collapse
|
61
|
Imaging of Scleral Collagen Deformation Using Combined Confocal Raman Microspectroscopy and Polarized Light Microscopy Techniques. PLoS One 2016; 11:e0165520. [PMID: 27806070 PMCID: PMC5091908 DOI: 10.1371/journal.pone.0165520] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2016] [Accepted: 10/13/2016] [Indexed: 11/25/2022] Open
Abstract
This work presents an optospectroscopic characterization technique for soft tissue microstructure using site-matched confocal Raman microspectroscopy and polarized light microscopy. Using the technique, the microstructure of soft tissue samples is directly observed by polarized light microscopy during loading while spatially correlated spectroscopic information is extracted from the same plane, verifying the orientation and arrangement of the collagen fibers. Results show the response and orientation of the collagen fiber arrangement in its native state as well as during tensile and compressive loadings in a porcine sclera model. An example is also given showing how the data can be used with a finite element program to estimate the strain in individual collagen fibers. The measurements demonstrate features that indicate microstructural reorganization and damage of the sclera’s collagen fiber arrangement under loading. The site-matched confocal Raman microspectroscopic characterization of the tissue provides a qualitative measure to relate the change in fibrillar arrangement with possible chemical damage to the collagen microstructure. Tests and analyses presented here can potentially be used to determine the stress-strain behavior, and fiber reorganization of the collagen microstructure in soft tissue during viscoelastic response.
Collapse
|
62
|
Liu R, Li N, Lin Y, Wang M, Peng Y, Lewi K, Wang Q. Glucagon Like Peptide-1 Promotes Adipocyte Differentiation via the Wnt4 Mediated Sequestering of Beta-Catenin. PLoS One 2016; 11:e0160212. [PMID: 27504979 PMCID: PMC4978386 DOI: 10.1371/journal.pone.0160212] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2016] [Accepted: 07/17/2016] [Indexed: 01/22/2023] Open
Abstract
Glucagon-like peptide-1 (GLP-1) plays a role in the regulation of adipogenesis; however, the precise underlying molecular mechanism has not been fully defined. Wnt was recently identified as an important regulator of adipogenesis. This study aimed to investigate the involvement of the Wnt signaling pathway in the effects of GLP-1 on adipocyte differentiation. 3T3-L1 cells were induced to differentiate. The changes in the expression levels of adipogenic transcription factors and Wnts and the phosphorylation level and subcellular localization of β-catenin were quantified after GLP-1 treatment. GLP-1 stimulated adipocyte differentiation and lipid accumulation, which were accompanied by the expression of adipocyte marker genes. The expression of Wnt4 was upregulated in the process of adipocyte differentiation, which was further enhanced by treatment with GLP-1. β-catenin, an important mediator of the Wnt pathway, was immediately dephosphorylated and translocated from cytoplasm to nucleus when differentiation was induced. In the presence of GLP-1, however, β-catenin was redirected to the cell plasma membrane leading to its decreased accumulation in the nucleus. Knockdown of Wnt4 blocked the effect of GLP-1 on the cellular localization of β-catenin and expression level of adipogenic transcription factors. Our findings showed that GLP-1 promoted adipogenesis through the modulation of the Wnt4/β-catenin signaling pathway, suggesting that the GLP-1-Wntβ-catenin system might be a new target for the treatment of metabolic disease.
Collapse
Affiliation(s)
- Rui Liu
- Department of Endocrinology, Huashan Hospital, Fudan University, Shanghai 200040, China
- * E-mail:
| | - Na Li
- Department of Endocrinology, Shanghai First People’s Hospital, Shanghai Jiao TongUniversity, Shanghai 200080, China
| | - Yi Lin
- Department of Endocrinology, Shanghai First People’s Hospital, Shanghai Jiao TongUniversity, Shanghai 200080, China
| | - Mei Wang
- Department of Endocrinology, Shanghai First People’s Hospital, Shanghai Jiao TongUniversity, Shanghai 200080, China
| | - Yongde Peng
- Department of Endocrinology, Shanghai First People’s Hospital, Shanghai Jiao TongUniversity, Shanghai 200080, China
| | - Keidren Lewi
- Division of Endocrinology and Metabolism, Keenan Research Centre for Biomedical Science of St. Michael's Hospital, Departments of Physiology and Medicine, University of Toronto, Toronto, M5B 1W8, Canada
| | - Qinghua Wang
- Department of Endocrinology, Huashan Hospital, Fudan University, Shanghai 200040, China
- Division of Endocrinology and Metabolism, Keenan Research Centre for Biomedical Science of St. Michael's Hospital, Departments of Physiology and Medicine, University of Toronto, Toronto, M5B 1W8, Canada
| |
Collapse
|
63
|
Optical Coherence Tomographic Elastography Reveals Mesoscale Shear Strain Inhomogeneities in the Annulus Fibrosus. Spine (Phila Pa 1976) 2016; 41:E770-E777. [PMID: 26849796 PMCID: PMC4925193 DOI: 10.1097/brs.0000000000001463] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Basic science study using in vitro tissue testing and imaging to characterize local strains in annulus fibrosus (AF) tissue. OBJECTIVE To characterize mesoscale strain inhomogeneities between lamellar and inter-/translamellar (ITL) matrix compartments during tissue shear loading. SUMMARY OF BACKGROUND DATA The intervertebral disc is characterized by significant heterogeneities in tissue structure and plays a critical role in load distribution and force transmission in the spine. In particular, the AF possesses a lamellar architecture interdigitated by a complex network of extracellular matrix components that form a distinct ITL compartment. Currently, there is not a firm understanding of how the lamellar and ITL matrix coordinately support tissue loading. METHODS AF tissue samples were prepared from frozen porcine lumbar spines and mounted onto custom fixtures of a materials testing system that incorporates optical coherence tomography (OCT) imaging to perform tissue elastography. Tissues were subjected to 20 and 40% nominal shear strain, and OCT images were captured and segmented to identify regions of interest corresponding to lamellar and ITL compartments. Images were analyzed using an optical flow algorithm to quantify local shear strains within each compartment. RESULTS Using histology and OCT, we first verified our ability to visualize and discriminate the ITL matrix from the lamellar matrix in porcine AF tissues. Local AF strains in the ITL compartment (22.0 ± 13.8, 31.1 ± 16.9 at 20% and 40% applied shear, respectively) were significantly higher than corresponding strains in the surrounding lamellar compartment (12.1 ± 5.6, 15.3 ± 5.2) for all tissue samples (P < 0.05). CONCLUSION Results from this study demonstrate that the lamellar and ITL compartments of the AF distribute strain unevenly during tissue loading. Specifically, shear strain is significantly higher in the ITL matrix, suggesting that these regions may be more susceptible to tissue damage and more mechanobiologically active. LEVEL OF EVIDENCE N/A.
Collapse
|
64
|
Baldwin SJ, Kreplak L, Lee JM. Characterization via atomic force microscopy of discrete plasticity in collagen fibrils from mechanically overloaded tendons: Nano-scale structural changes mimic rope failure. J Mech Behav Biomed Mater 2016; 60:356-366. [DOI: 10.1016/j.jmbbm.2016.02.004] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2015] [Revised: 01/22/2016] [Accepted: 02/03/2016] [Indexed: 10/22/2022]
|
65
|
Mozdzen LC, Thorpe S, Screen HR, Harley BA. The Effect of Gradations in Mineral Content, Matrix Alignment, and Applied Strain on Human Mesenchymal Stem Cell Morphology within Collagen Biomaterials. Adv Healthc Mater 2016; 5:1731-9. [PMID: 27245787 PMCID: PMC4978129 DOI: 10.1002/adhm.201600181] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2016] [Revised: 04/12/2016] [Indexed: 12/19/2022]
Abstract
The tendon-bone junction is a unique, mechanically dynamic, structurally graded anatomical zone, which transmits tensile loads between tendon and bone. Current surgical repair techniques rely on mechanical fixation and can result in high re-failure rates. A new class of collagen biomaterial that contains discrete mineralized and structurally aligned regions linked by a continuous interface to mimic the graded osteotendinous insertion has been recently described. Here the combined influence of graded biomaterial environment and increasing levels of applied strain (0%-20%) on mesenchymal stem cell (MSC) orientation and alignment have been reported. In osteotendinous scaffolds, which contain opposing gradients of mineral content and structural alignment characteristic of the native osteotendinous interface, MSC nuclear, and actin alignment is initially dictated by the local pore architecture, while applied tensile strain enhances cell alignment in the direction of strain. Comparatively, in layered scaffolds that do not contain any structural alignment cues, MSCs are randomly oriented in the unstrained condition, then become oriented in a direction perpendicular to applied strain. These findings provide an initial understanding of how scaffold architecture can provide significant, potentially competitive, feedback influencing MSC orientation under applied strain, and form the basis for future tissue engineering efforts to regenerate the osteotendinous enthesis.
Collapse
Affiliation(s)
- Laura C. Mozdzen
- 193 Roger Adams Laboratory, 600 S. Mathews St., Urbana, IL, 61801, USA
| | - Stephen Thorpe
- Queen Mary University of London, School of Engineering and Materials Science, Mile End Road, E1 4NS, London, UK
| | - Hazel R. Screen
- Queen Mary University of London, School of Engineering and Materials Science, Mile End Road, E1 4NS, London, UK
| | - Brendan A. Harley
- 110 Roger Adams Laboratory, 600 S. Mathews St, Urbana, IL, 61801, USA,
| |
Collapse
|
66
|
Li Y, Huang G, Li M, Wang L, Elson EL, Lu TJ, Genin GM, Xu F. An approach to quantifying 3D responses of cells to extreme strain. Sci Rep 2016; 6:19550. [PMID: 26887698 PMCID: PMC4757889 DOI: 10.1038/srep19550] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2015] [Accepted: 11/18/2015] [Indexed: 12/25/2022] Open
Abstract
The tissues of hollow organs can routinely stretch up to 2.5 times their length. Although significant pathology can arise if relatively large stretches are sustained, the responses of cells are not known at these levels of sustained strain. A key challenge is presenting cells with a realistic and well-defined three-dimensional (3D) culture environment that can sustain such strains. Here, we describe an in vitro system called microscale, magnetically-actuated synthetic tissues (micro-MASTs) to quantify these responses for cells within a 3D hydrogel matrix. Cellular strain-threshold and saturation behaviors were observed in hydrogel matrix, including strain-dependent proliferation, spreading, polarization, and differentiation, and matrix adhesion retained at strains sufficient for apoptosis. More broadly, the system shows promise for defining and controlling the effects of mechanical environment upon a broad range of cells.
Collapse
Affiliation(s)
- Yuhui Li
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China.,Bioinspired Engineering and Biomechanics Center, Xi'an Jiaotong University, Xi'an 710049, China
| | - Guoyou Huang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China.,Bioinspired Engineering and Biomechanics Center, Xi'an Jiaotong University, Xi'an 710049, China
| | - Moxiao Li
- Bioinspired Engineering and Biomechanics Center, Xi'an Jiaotong University, Xi'an 710049, China
| | - Lin Wang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China.,Bioinspired Engineering and Biomechanics Center, Xi'an Jiaotong University, Xi'an 710049, China.,Department of Biochemistry and Molecular Biophysics, Saint Louis, Missouri 63110, USA
| | - Elliot L Elson
- Bioinspired Engineering and Biomechanics Center, Xi'an Jiaotong University, Xi'an 710049, China.,Department of Biochemistry and Molecular Biophysics, Saint Louis, Missouri 63110, USA.,Department of Mechanical Engineering and Materials Science, Washington University, Saint Louis, Missouri 63130, USA
| | - Tian Jian Lu
- Bioinspired Engineering and Biomechanics Center, Xi'an Jiaotong University, Xi'an 710049, China
| | - Guy M Genin
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China.,Bioinspired Engineering and Biomechanics Center, Xi'an Jiaotong University, Xi'an 710049, China.,Department of Neurological Surgery, Washington University School of Medicine, Saint Louis, Missouri 63110, USA.,Department of Mechanical Engineering and Materials Science, Washington University, Saint Louis, Missouri 63130, USA
| | - Feng Xu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China.,Bioinspired Engineering and Biomechanics Center, Xi'an Jiaotong University, Xi'an 710049, China
| |
Collapse
|
67
|
Jayyosi C, Coret M, Bruyère-Garnier K. Characterizing liver capsule microstructure via in situ bulge test coupled with multiphoton imaging. J Mech Behav Biomed Mater 2016; 54:229-43. [DOI: 10.1016/j.jmbbm.2015.09.031] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2015] [Revised: 09/23/2015] [Accepted: 09/24/2015] [Indexed: 10/22/2022]
|
68
|
Collagen Homeostasis and Metabolism. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2016; 920:11-25. [DOI: 10.1007/978-3-319-33943-6_2] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
69
|
Fang F, Lake SP. Multiscale strain analysis of tendon subjected to shear and compression demonstrates strain attenuation, fiber sliding, and reorganization. J Orthop Res 2015; 33:1704-12. [PMID: 26036894 DOI: 10.1002/jor.22955] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2014] [Accepted: 05/21/2015] [Indexed: 02/04/2023]
Abstract
The manner in which strains are passed down the hierarchical length scales of tendons dictates how cells within the collagen network regulate the tissue response to loading. How tendons deform in different hierarchical levels under shear and compression is unknown. The aims of this study were: (i) to evaluate whether specific regions of bovine deep digital flexor tendons exhibited different strain attenuation from macro to micro length scales, and (ii) to elucidate mechanisms responsible for tendon deformation under shear and compression. Samples from distal and proximal regions of flexor tendons were subjected to three-step incremental stress-relaxation tests. Images of tissue markers, photobleached lines on collagen fibers, and nuclei locations were collected before and after loading. Results showed that strain transfer was attenuated from tissue to local matrix under both shear and compression. Nuclear aspect ratios exhibited smaller changes for distal samples, suggesting that cells are more shielded from deformation in the distal region. Collagen fiber sliding was observed to contribute significantly in response to shear, while uncrimping and fiber reorganization were the predominant mechanisms under compression. This study provides insight into microscale mechanisms responsible for multiscale strain attenuation of tendons under non-tensile macroscale loading.
Collapse
Affiliation(s)
- Fei Fang
- Department of Mechanical Engineering & Materials Science, Washington University, St. Louis, Missouri
| | - Spencer P Lake
- Department of Mechanical Engineering & Materials Science, Washington University, St. Louis, Missouri.,Department of Biomedical Engineering, Washington University, St. Louis, Missouri.,Department of Orthopaedic Surgery, Washington University, St. Louis, Missouri
| |
Collapse
|
70
|
Szczesny SE, Caplan JL, Pedersen P, Elliott DM. Quantification of Interfibrillar Shear Stress in Aligned Soft Collagenous Tissues via Notch Tension Testing. Sci Rep 2015; 5:14649. [PMID: 26469396 PMCID: PMC4606738 DOI: 10.1038/srep14649] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2014] [Accepted: 09/02/2015] [Indexed: 11/29/2022] Open
Abstract
The mechanical function of soft collagenous tissues is largely determined by their hierarchical organization of collagen molecules. While collagen fibrils are believed to be discontinuous and transfer load through shearing of the interfibrillar matrix, interfibrillar shear stresses have never been quantified. Scaling traditional shear testing procedures down to the fibrillar length scale is impractical and would introduce substantial artifacts. Here, through the use of a novel microscopic variation of notch tension testing, we explicitly demonstrate the existence of interfibrillar shear stresses within tendon fascicles and provide the first measurement of their magnitude. Axial stress gradients along the sample length generated by notch tension testing were measured and used to calculate a value of 32 kPa for the interfibrillar shear stress. This estimate is comparable to the interfibrillar shear stress predicted by previous multiscale modeling of tendon fascicles, which supports the hypothesis that fibrils are discontinuous and transmit load through interfibrillar shear. This information regarding the structure-function relationships of tendon and other soft collagenous tissues is necessary to identify potential causes for tissue impairment with degeneration and provide the foundation for developing regenerative repair strategies or engineering biomaterials for tissue replacement.
Collapse
Affiliation(s)
- Spencer E Szczesny
- Department of Bioengineering. University of Pennsylvania, 240 Skirkanich Hall, 210 South 33rd St, Philadelphia, PA 19104
| | - Jeffrey L Caplan
- Delaware Biotechnology Institute, 15 Innovation Way, Suite 117, Newark, DE 19716
| | - Pal Pedersen
- Carl Zeiss Microscopy, One Zeiss Drive, Thornwood, NY 10594
| | - Dawn M Elliott
- Department of Biomedical Engineering, University of Delaware, 161 Colburn Lab, 150 Academy Street, Newark, DE 19716
| |
Collapse
|
71
|
Thorpe CT, Spiesz EM, Chaudhry S, Screen HRC, Clegg PD. Science in brief: recent advances into understanding tendon function and injury risk. Equine Vet J 2015; 47:137-40. [PMID: 25644766 DOI: 10.1111/evj.12346] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Affiliation(s)
- C T Thorpe
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, UK
| | | | | | | | | |
Collapse
|
72
|
Shearer T. A new strain energy function for modelling ligaments and tendons whose fascicles have a helical arrangement of fibrils. J Biomech 2015; 48:3017-25. [DOI: 10.1016/j.jbiomech.2015.07.032] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2015] [Revised: 06/23/2015] [Accepted: 07/27/2015] [Indexed: 10/23/2022]
|
73
|
Kondratko-Mittnacht J, Lakes R, Vanderby R. Shear loads induce cellular damage in tendon fascicles. J Biomech 2015; 48:3299-305. [PMID: 26162546 DOI: 10.1016/j.jbiomech.2015.06.006] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2015] [Revised: 05/26/2015] [Accepted: 06/17/2015] [Indexed: 11/17/2022]
Abstract
Tendon is vital to musculoskeletal function, transferring loads from muscle to bone for joint motion and stability. It is an anisotropic, highly organized, fibrous structure containing primarily type I collagen in addition to tenocytes and other extracellular matrix components contributing to maintenance and function. Tendon is generally loaded via normal stress in a longitudinal direction. However, certain situations, including fiber breakage, enzymatic remodeling, or tendon pathology may introduce various degrees of other loading modalities, such as shear-lag at the fiber level, potentially affecting cellular response and subsequent function. Fascicles from rat tail tendon were dissected and placed in one of three paired groups: intact, single laceration, or double laceration. Each pair had a mechanically tested and control specimen. Single laceration fascicles contained one transverse laceration to mimic a partial tear. Double laceration fascicles had overlapping, longitudinally separated lacerations on opposite sides to cause intra-fascicular shear transfer to be the primary mechanism of loading. Elastic properties of the fascicle, e.g. peak load, steady state load, and stiffness, decreased from intact to single laceration to double laceration groups. Surprisingly, 45% of the intact strength was maintained when shear was the primary internal load transfer mechanism. Cellular viability decreased after mechanical testing in both laceration groups; cell death appeared primarily in a longitudinal plane where high shear load transfer occurred. This cell death extended far from the injury site and may further compromise an already damaged tendon via enzymatic factors and subsequent remodeling associated with cell necrosis.
Collapse
Affiliation(s)
- Jaclyn Kondratko-Mittnacht
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, 53705 WI, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, 53705 WI, USA
| | - Roderic Lakes
- Materials Science Program, University of Wisconsin-Madison, Madison, 53705 WI, USA; Department of Engineering Physics, University of Wisconsin-Madison, Madison, 53705 WI, USA
| | - Ray Vanderby
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, 53705 WI, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, 53705 WI, USA; Materials Science Program, University of Wisconsin-Madison, Madison, 53705 WI, USA.
| |
Collapse
|
74
|
Screen HRC, Berk DE, Kadler KE, Ramirez F, Young MF. Tendon functional extracellular matrix. J Orthop Res 2015; 33:793-9. [PMID: 25640030 PMCID: PMC4507431 DOI: 10.1002/jor.22818] [Citation(s) in RCA: 133] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2014] [Accepted: 12/13/2014] [Indexed: 02/06/2023]
Abstract
This article is one of a series, summarizing views expressed at the Orthopaedic Research Society New Frontiers in Tendon Research Conference. This particular article reviews the three workshops held under the "Functional Extracellular Matrix" stream. The workshops focused on the roles of the tendon extracellular matrix, such as performing the mechanical functions of tendon, creating the local cell environment, and providing cellular cues. Tendon is a complex network of matrix and cells, and its biological functions are influenced by widely varying extrinsic and intrinsic factors such as age, nutrition, exercise levels, and biomechanics. Consequently, tendon adapts dynamically during development, aging, and injury. The workshop discussions identified research directions associated with understanding cell-matrix interactions to be of prime importance for developing novel strategies to target tendon healing or repair.
Collapse
Affiliation(s)
- Hazel R C Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London, E1 4NS, United Kingdom
| | | | | | | | | |
Collapse
|
75
|
Connizzo BK, Freedman BR, Fried JH, Sun M, Birk DE, Soslowsky LJ. Regulatory role of collagen V in establishing mechanical properties of tendons and ligaments is tissue dependent. J Orthop Res 2015; 33:882-8. [PMID: 25876927 PMCID: PMC4417070 DOI: 10.1002/jor.22893] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2014] [Accepted: 03/10/2015] [Indexed: 02/04/2023]
Abstract
Patients with classic (type I) Ehlers-Danlos syndrome (EDS), characterized by heterozygous mutations in the Col5a1 and Col5a2 genes, exhibit connective tissue hyperelasticity and recurrent joint dislocations, indicating a potential regulatory role for collagen V in joint stabilizing soft tissues. This study asked whether the contribution of collagen V to the establishment of mechanical properties is tissue dependent. We mechanically tested four different tissues from wild type and targeted collagen V-null mice: the flexor digitorum longus (FDL) tendon, Achilles tendon (ACH), the anterior cruciate ligament (ACL), and the supraspinatus tendon (SST). Area was significantly reduced in the Col5a1(ΔTen/ΔTen) group in the FDL, ACH, and SST. Maximum load and stiffness were reduced in the Col5a1(ΔTen/ΔTen) group for all tissues. However, insertion site and midsubstance modulus were reduced only for the ACL and SST. This study provides evidence that the regulatory role of collagen V in extracellular matrix assembly is tissue dependent and that joint instability in classic EDS may be caused in part by insufficient mechanical properties of the tendons and ligaments surrounding each joint.
Collapse
Affiliation(s)
- Brianne K. Connizzo
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, 424 Stemmler Hall, 36 and Hamilton Walk, Philadelphia, PA, 19104-6081
| | - Benjamin R. Freedman
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, 424 Stemmler Hall, 36 and Hamilton Walk, Philadelphia, PA, 19104-6081
| | - Joanna H. Fried
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, 424 Stemmler Hall, 36 and Hamilton Walk, Philadelphia, PA, 19104-6081
| | - Mei Sun
- Department of Molecular Pharmacology & Physiology, Morsani College of Medicine, University of South Florida, Tampa, FL 33612
| | - David E. Birk
- Department of Molecular Pharmacology & Physiology, Morsani College of Medicine, University of South Florida, Tampa, FL 33612
| | - Louis J. Soslowsky
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, 424 Stemmler Hall, 36 and Hamilton Walk, Philadelphia, PA, 19104-6081,Correspondence to: Louis J. Soslowsky, 424 Stemmler Hall, 36 and Hamilton Walk, Philadelphia, PA, 19104-6081, T:215-898-8653, F:215-573-2133,
| |
Collapse
|
76
|
Filius A, Thoreson AR, Wang Y, Passe SM, Zhao C, An KN, Amadio PC. The effect of tendon excursion velocity on longitudinal median nerve displacement: differences between carpal tunnel syndrome patients and controls. J Orthop Res 2015; 33:483-7. [PMID: 25640903 PMCID: PMC5168720 DOI: 10.1002/jor.22804] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2014] [Accepted: 12/04/2014] [Indexed: 02/06/2023]
Abstract
The subsynovial connective tissue (SSCT) is a viscoelastic structure connecting the median nerve (MN) and the flexor tendons in the carpal tunnel. Increased strain rates increases stiffness in viscoelastic tissues, and thereby its capacity to transfer shear load. Therefore, tendon excursion velocity may impact the MN displacement. In carpal tunnel syndrome (CTS) the SSCT is fibrotic and may be ruptured, and this may affect MN motion. In this study, ultrasonography was performed on 14 wrists of healthy controls and 25 wrists of CTS patients during controlled finger motions performed at three different velocities. Longitudinal MN and tendon excursion were assessed using a custom speckle tracking algorithm and compared across the three different velocities. CTS patients exhibited significantly less MN motion than controls (p ≤ 0.002). While in general, MN displacement increased with increasing tendon excursion velocity (p ≤ 0.031). These findings are consistent with current knowledge of SSCT mechanics in CTS, in which in some patients the fibrotic SSCT appears to have ruptured from the tendon surface.
Collapse
Affiliation(s)
- Anika Filius
- Biomechanics Laboratory and the Tendon & Soft Tissue Biology Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester Minnesota,,Department of Plastic, Reconstructive and Hand Surgery, and the Department of Rehabilitation Medicine and Physical Therapy, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Andrew R. Thoreson
- Biomechanics Laboratory and the Tendon & Soft Tissue Biology Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester Minnesota
| | - Yuexiang Wang
- Biomechanics Laboratory and the Tendon & Soft Tissue Biology Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester Minnesota
| | - Sandra M. Passe
- Biomechanics Laboratory and the Tendon & Soft Tissue Biology Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester Minnesota
| | - Chunfeng Zhao
- Biomechanics Laboratory and the Tendon & Soft Tissue Biology Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester Minnesota
| | - Kai-Nan An
- Biomechanics Laboratory and the Tendon & Soft Tissue Biology Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester Minnesota
| | - Peter C. Amadio
- Biomechanics Laboratory and the Tendon & Soft Tissue Biology Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester Minnesota
| |
Collapse
|
77
|
Böl M, Ehret AE, Leichsenring K, Ernst M. Tissue-scale anisotropy and compressibility of tendon in semi-confined compression tests. J Biomech 2015; 48:1092-8. [DOI: 10.1016/j.jbiomech.2015.01.024] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2014] [Revised: 01/16/2015] [Accepted: 01/20/2015] [Indexed: 01/22/2023]
|
78
|
The Mechanical, Structural, and Compositional Changes of Tendon Exposed to Elastase. Ann Biomed Eng 2015; 43:2477-86. [PMID: 25808209 DOI: 10.1007/s10439-015-1308-5] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2014] [Accepted: 03/20/2015] [Indexed: 01/24/2023]
Abstract
The mechanical response of tendon is dependent on the interaction of structural molecules that constitute the extracellular matrix. However, little is known about the role of elastic fibers that are present in this structure. Elastase treatments have been used to elucidate the mechanical role of elastic fibers in numerous tissues. Here, we show that a standard elastase treatment affects the mechanical properties of tendon, including the ultimate tensile strength and failure strain. Moreover, elastase-treated specimens exhibit significant structural and compositional changes including crimp undulation and release of glycosaminoglycans. These data demonstrate that a common elastase treatment has a complex digestion profile that influences the structure-function relationship of tendon. Thus, defining the mechanical role of elastic fibers in tendon using this technique is challenging. This introduces new and exciting questions regarding the function of elastic fibers in tendon, which may not be as well understood as previously thought.
Collapse
|
79
|
Wilkie IC, Fassini D, Cullorà E, Barbaglio A, Tricarico S, Sugni M, Del Giacco L, Candia Carnevali MD. Mechanical properties of the compass depressors of the sea-urchin Paracentrotus lividus (Echinodermata, Echinoidea) and the effects of enzymes, neurotransmitters and synthetic tensilin-like protein. PLoS One 2015; 10:e0120339. [PMID: 25786033 PMCID: PMC4365025 DOI: 10.1371/journal.pone.0120339] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2014] [Accepted: 01/22/2015] [Indexed: 01/08/2023] Open
Abstract
The compass depressors (CDs) of the sea-urchin lantern are ligaments consisting mainly of discontinuous collagen fibrils associated with a small population of myocytes. They are mutable collagenous structures, which can change their mechanical properties rapidly and reversibly under nervous control. The aims of this investigation were to characterise the baseline (i.e. unmanipulated) static mechanical properties of the CDs of Paracentrotus lividus by means of creep tests and incremental force-extension tests, and to determine the effects on their mechanical behaviour of a range of agents. Under constant load the CDs exhibited a three-phase creep curve, the mean coefficient of viscosity being 561±365 MPa.s. The stress-strain curve showed toe, linear and yield regions; the mean strain at the toe-linear inflection was 0.86±0.61; the mean Young's modulus was 18.62±10.30 MPa; and the mean tensile strength was 8.14±5.73 MPa. Hyaluronidase from Streptomyces hyalurolyticus had no effect on creep behaviour, whilst chondroitinase ABC prolonged primary creep but had no effect on secondary creep or on any force-extension parameters; it thus appears that neither hyaluronic acid nor sulphated glycosaminoglycans have an interfibrillar load transfer function in the CD. Acetylcholine, the muscarinic agonists arecoline and methacholine, and the nicotinic agonists nicotine and 1-[1-(3,4-dimethyl-phenyl)-ethyl]-piperazine produced an abrupt increase in CD viscosity; the CDs were not differentially sensitive to muscarinic or nicotinic agonists. CDs showed either no, or no consistent, response to adrenaline, L-glutamic acid, 5-hydroxytryptamine and γ-aminobutyric acid. Synthetic echinoid tensilin-like protein had a weak and inconsistent stiffening effect, indicating that, in contrast to holothurian tensilins, the echinoid molecule may not be involved in the regulation of collagenous tissue tensility. We compare in detail the mechanical behaviour of the CD with that of mammalian tendon and highlight its potential as a model system for investigating poorly understood aspects of the ontogeny and phylogeny of vertebrate collagenous tissues.
Collapse
Affiliation(s)
- Iain C. Wilkie
- Department of Life Sciences, Glasgow Caledonian University, Glasgow, Scotland, United Kingdom
| | - Dario Fassini
- Dipartimento di Bioscienze, Università degli Studi di Milano, Milano, Italy
| | - Emanuele Cullorà
- Dipartimento di Bioscienze, Università degli Studi di Milano, Milano, Italy
| | - Alice Barbaglio
- Dipartimento di Bioscienze, Università degli Studi di Milano, Milano, Italy
| | - Serena Tricarico
- Dipartimento di Bioscienze, Università degli Studi di Milano, Milano, Italy
| | - Michela Sugni
- Dipartimento di Bioscienze, Università degli Studi di Milano, Milano, Italy
| | - Luca Del Giacco
- Dipartimento di Bioscienze, Università degli Studi di Milano, Milano, Italy
| | | |
Collapse
|
80
|
CILINGIR AHMETC. EFFECTS OF CULTURE PERIODS AND LOADING ON BIOMECHANICAL PROPERTIES OF SHEEP COLLAGEN FASCICLES. J MECH MED BIOL 2014. [DOI: 10.1142/s0219519414400107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Soft tissues (e.g., tendon, skin, cartilage) change their dimensions and properties in response to applied mechanical stress/strain, which is called remodeling. Experimental studies using tissue cultures were performed to understand the biomechanical properties of collagen fascicles under mechanical loads. Collagen fascicles were dissected from sheep Achilles tendons and loaded under 1, 2, and 3 kg for 2, 4, and 6 days under culture. The mechanical properties of collagen fascicles after being loaded into the culture media were determined using tensile tester, and resultant stress–strain curves, tangent modulus, tensile strength, and strain at failure values were compared with those in a non-loaded and non-cultured control group of fascicles. The tangent modulus and tensile strength of the collagen fascicles increased with the increasing remodeling load after two days of culture. However, these values gradually decreased with the increasing culture period compared with the control group. According to the results obtained in this study, the mechanical properties of collagen fascicles were improved by loading at two days of culture, most likely due to the remodeling of collagen fibers. However, after a period of remodeling, local strains on the collagen fibrils increased, and finally, the collagen fibrils broke down, decreasing the mechanical properties of the tissue.
Collapse
Affiliation(s)
- AHMET C. CILINGIR
- Mechanical Engineering Department, Sakarya University, Esentepe Campus, 54187 Sakarya, Turkey
| |
Collapse
|
81
|
Szczesny SE, Elliott DM. Incorporating plasticity of the interfibrillar matrix in shear lag models is necessary to replicate the multiscale mechanics of tendon fascicles. J Mech Behav Biomed Mater 2014; 40:325-338. [PMID: 25262202 DOI: 10.1016/j.jmbbm.2014.09.005] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2014] [Revised: 08/26/2014] [Accepted: 09/02/2014] [Indexed: 11/18/2022]
Abstract
Despite current knowledge of tendon structure, the fundamental deformation mechanisms underlying tendon mechanics and failure are unknown. We recently showed that a shear lag model, which explicitly assumed plastic interfibrillar load transfer between discontinuous fibrils, could explain the multiscale fascicle mechanics, suggesting that fascicle yielding is due to plastic deformation of the interfibrillar matrix. However, it is unclear whether alternative physical mechanisms, such as elastic interfibrillar deformation or fibril yielding, also contribute to fascicle mechanical behavior. The objective of the current work was to determine if plasticity of the interfibrillar matrix is uniquely capable of explaining the multiscale mechanics of tendon fascicles including the tissue post-yield behavior. This was examined by comparing the predictions of a continuous fibril model and three separate shear lag models incorporating an elastic, plastic, or elastoplastic interfibrillar matrix with multiscale experimental data. The predicted effects of fibril yielding on each of these models were also considered. The results demonstrated that neither the continuous fibril model nor the elastic shear lag model can successfully predict the experimental data, even if fibril yielding is included. Only the plastic or elastoplastic shear lag models were capable of reproducing the multiscale tendon fascicle mechanics. Differences between these two models were small, although the elastoplastic model did improve the fit of the experimental data at low applied tissue strains. These findings suggest that while interfibrillar elasticity contributes to the initial stress response, plastic deformation of the interfibrillar matrix is responsible for tendon fascicle post-yield behavior. This information sheds light on the physical processes underlying tendon failure, which is essential to improve our understanding of tissue pathology and guide the development of successful repair.
Collapse
Affiliation(s)
- Spencer E Szczesny
- Department of Bioengineering, University of Pennsylvania, 240 Skirkanich Hall, 210 South 33rd St, Philadelphia, PA 19104, United States.
| | - Dawn M Elliott
- Department of Biomedical Engineering, University of Delaware, 125 East Delaware Avenue, Newark, DE 19716, United States.
| |
Collapse
|
82
|
Bonner TJ, Newell N, Karunaratne A, Pullen AD, Amis AA, M J Bull A, Masouros SD. Strain-rate sensitivity of the lateral collateral ligament of the knee. J Mech Behav Biomed Mater 2014; 41:261-70. [PMID: 25086777 DOI: 10.1016/j.jmbbm.2014.07.004] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2014] [Revised: 06/28/2014] [Accepted: 07/01/2014] [Indexed: 02/04/2023]
Abstract
The material properties of ligaments are not well characterized at rates of deformation that occur during high-speed injuries. The aim of this study was to measure the material properties of lateral collateral ligament of the porcine stifle joint in a uniaxial tension model through strain rates in the range from 0.01 to 100/s. Failure strain, tensile modulus and failure stress were calculated. Across the range of strain rates, tensile modulus increased from 288 to 905 MPa and failure stress increased from 39.9 to 77.3 MPa. The strain-rate sensitivity of the material properties decreased as deformation rates increased, and reached a limit at approximately 1/s, beyond which there was no further significant change. In addition, time resolved microfocus small angle X-ray scattering was used to measure the effective fibril modulus (stress/fibril strain) and fibril to tissue strain ratio. The nanoscale data suggest that the contribution of the collagen fibrils towards the observed tissue-level deformation of ligaments diminishes as the loading rate increases. These findings help to predict the patterns of limb injuries that occur at different speeds and improve computational models used to assess and develop mitigation technology.
Collapse
Affiliation(s)
- Timothy J Bonner
- The Academic Department of Military Surgery and Trauma, The Royal Centre for Defence Medicine, Birmingham B15 2SQ, UK; Department of Bioengineering, Imperial College London, London SW7 2AZ, UK
| | - Nicolas Newell
- Department of Bioengineering, Imperial College London, London SW7 2AZ, UK
| | - Angelo Karunaratne
- Department of Bioengineering, Imperial College London, London SW7 2AZ, UK
| | - Andy D Pullen
- Department of Civil and Environmental Engineering, Imperial College London, London SW7 2AZ, UK
| | - Andrew A Amis
- Department of Mechanical Engineering, Imperial College London, London SW7 2AZ, UK; Department of Musculoskeletal Surgery, Imperial College London, London W6 8RF, UK
| | - Anthony M J Bull
- Department of Bioengineering, Imperial College London, London SW7 2AZ, UK
| | - Spyros D Masouros
- Department of Bioengineering, Imperial College London, London SW7 2AZ, UK.
| |
Collapse
|
83
|
Shepherd JH, Riley GP, Screen HRC. Early stage fatigue damage occurs in bovine tendon fascicles in the absence of changes in mechanics at either the gross or micro-structural level. J Mech Behav Biomed Mater 2014; 38:163-72. [PMID: 25001495 PMCID: PMC4148183 DOI: 10.1016/j.jmbbm.2014.06.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2014] [Revised: 06/01/2014] [Accepted: 06/04/2014] [Indexed: 12/04/2022]
Abstract
Many tendon injuries are believed to result from repetitive motion or overuse, leading to the accumulation of micro-damage over time. In vitro fatigue loading can be used to characterise damage during repeated use and investigate how this may relate to the aetiology of tendinopathy. This study considered the effect of fatigue loading on fascicles from two functionally distinct bovine tendons: the digital extensor and deep digital flexor. Micro-scale extension mechanisms were investigated in fascicles before or after a period of cyclic creep loading, comparing two different measurement techniques – the displacement of a photo-bleached grid and the use of nuclei as fiducial markers. Whilst visual damage was clearly identified after only 300 cycles of creep loading, these visual changes did not affect either gross fascicle mechanics or fascicle microstructural extension mechanisms over the 900 fatigue cycles investigated. However, significantly greater fibre sliding was measured when observing grid deformation rather than the analysis of nuclei movement. Measurement of microstructural extension with both techniques was localised and this may explain the absence of change in microstructural deformation in response to fatigue loading. Alternatively, the data may demonstrate that fascicles can withstand a degree of matrix disruption with no impact on mechanics. Whilst use of a photo-bleached grid to directly measure the collagen is the best indicator of matrix deformation, nuclei tracking may provide a better measure of the strain perceived directly by the cells. Tendon fascicle gross mechanics and micro-scale deformation investigated after fatigue loading. Fascicles can withstand a degree of matrix disruption without impact on mechanics. More fibre sliding was observed measuring grid deformation than tracking nuclei. Nuclei tracking may better represent the strains experienced by cells than grid deformation.
Collapse
Affiliation(s)
- Jennifer H Shepherd
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary, University of London, Mile End Road, E1 4NS, UK
| | - Graham P Riley
- School of Biological Sciences, University of East Anglia, UK
| | - Hazel R C Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary, University of London, Mile End Road, E1 4NS, UK.
| |
Collapse
|
84
|
Thorpe CT, Riley GP, Birch HL, Clegg PD, Screen HR. Effect of fatigue loading on structure and functional behaviour of fascicles from energy-storing tendons. Acta Biomater 2014; 10:3217-24. [PMID: 24747261 DOI: 10.1016/j.actbio.2014.04.008] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2013] [Revised: 03/07/2014] [Accepted: 04/08/2014] [Indexed: 11/26/2022]
Abstract
Tendons can broadly be categorized according to their function: those that act purely to position the limb and those that have an additional function as energy stores. Energy-storing tendons undergo many cycles of large deformations during locomotion, and so must be able to extend and recoil efficiently, rapidly and repeatedly. Our previous work has shown rotation in response to applied strain in fascicles from energy-storing tendons, indicating the presence of helical substructures which may provide greater elasticity and recovery. In the current study, we assessed how preconditioning and fatigue loading affect the ability of fascicles from the energy-storing equine superficial digital flexor tendon to extend and recoil. We hypothesized that preconditioned samples would exhibit changes in microstructural strain response, but would retain their ability to recover. We further hypothesized that fatigue loading would result in sample damage, causing further alterations in extension mechanisms and a significant reduction in sample recovery. The results broadly support these hypotheses: preconditioned samples showed some alterations in microstructural strain response, but were able to recover following the removal of load. However, fatigue loaded samples showed visual evidence of damage and exhibited further alterations in extension mechanisms, characterized by decreased rotation in response to applied strain. This was accompanied by increased hysteresis and decreased recovery. These results suggest that fatigue loading results in a compromised helix substructure, reducing the ability of energy-storing tendons to recoil. A decreased ability to recoil may lead to an impaired response to further loading, potentially increasing the likelihood of injury.
Collapse
|
85
|
Szczesny SE, Edelstein RS, Elliott DM. DTAF dye concentrations commonly used to measure microscale deformations in biological tissues alter tissue mechanics. PLoS One 2014; 9:e99588. [PMID: 24915570 PMCID: PMC4051763 DOI: 10.1371/journal.pone.0099588] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2014] [Accepted: 05/16/2014] [Indexed: 11/18/2022] Open
Abstract
Identification of the deformation mechanisms and specific components underlying the mechanical function of biological tissues requires mechanical testing at multiple levels within the tissue hierarchical structure. Dichlorotriazinylaminofluorescein (DTAF) is a fluorescent dye that is used to visualize microscale deformations of the extracellular matrix in soft collagenous tissues. However, the DTAF concentrations commonly employed in previous multiscale experiments (≥2000 µg/ml) may alter tissue mechanics. The objective of this study was to determine whether DTAF affects tendon fascicle mechanics and if a concentration threshold exists below which any observed effects are negligible. This information is valuable for guiding the continued use of this fluorescent dye in future experiments and for interpreting the results of previous work. Incremental strain testing demonstrated that high DTAF concentrations (≥100 µg/ml) increase the quasi-static modulus and yield strength of rat tail tendon fascicles while reducing their viscoelastic behavior. Subsequent multiscale testing and modeling suggests that these effects are due to a stiffening of the collagen fibrils and strengthening of the interfibrillar matrix. Despite these changes in tissue behavior, the fundamental deformation mechanisms underlying fascicle mechanics appear to remain intact, which suggests that conclusions from previous multiscale investigations of strain transfer are still valid. The effects of lower DTAF concentrations (≤10 µg/ml) on tendon mechanics were substantially smaller and potentially negligible; nevertheless, no concentration was found that did not at least slightly alter the tissue behavior. Therefore, future studies should either reduce DTAF concentrations as much as possible or use other dyes/techniques for measuring microscale deformations.
Collapse
Affiliation(s)
- Spencer E. Szczesny
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Rachel S. Edelstein
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware, United States of America
| | - Dawn M. Elliott
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware, United States of America
| |
Collapse
|
86
|
Han W, Heo SJ, Driscoll T, Boggs M, Duncan R, Mauck R, Elliott D. Impact of cellular microenvironment and mechanical perturbation on calcium signalling in meniscus fibrochondrocytes. Eur Cell Mater 2014; 27:321-31. [PMID: 24908425 PMCID: PMC4382367 DOI: 10.22203/ecm.v027a23] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Mechanical signals regulate a multitude of cell functions and ultimately govern fibrous tissue growth, maintenance and repair. Such mechanotransduction processes often involve modulation of intracellular calcium concentration ([Ca2+]i). However, most studies interrogate these responses in cells in simplified culture systems, thereby removing potentially important inputs from the native extracellular microenvironment. The objective of this study was to test the hypothesis that the intracellular calcium response of meniscus fibrochondrocytes (MFCs) is dependent on both the microenvironmental context in which this perturbation is applied and on the tensile deformation. Using a custom micro-mechanical tester mounted on a confocal microscope, intracellular calcium activity in MFCs in response to incremental tissue strains (0, 3, 6 and 9 %) was monitored in situ (i.e., in the native tissues) on MFC-seeded aligned scaffolds and MFC-seeded silicone membranes. The [Ca2+]i regulation by MFCs within the native meniscus tissue microenvironment was considerably different from [Ca2+]i regulation by MFCs on either aligned nanofibrous scaffolds or flat silicone membranes. Additionally, increasing levels of tensile deformation resulted in a greater number of responding cells, both in situ and in vitro, while having no effects on temporal characteristics of [Ca2+]i signalling. Collectively, these findings have significant implications for mechanobiology of load-bearing fibrous tissues and their responses to injury and degeneration. In addition, from a tissue engineering perspective, the findings establish cellular benchmarks for maturing engineered constructs, where native tissue-like calcium mechano-regulation may be an important outcome parameter to achieve mechanical functionality comparable to native tissue.
Collapse
Affiliation(s)
- W.M. Han
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA
| | - S-J. Heo
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA,Department of Orthopaedic Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - T.P. Driscoll
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA,Department of Orthopaedic Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - M.E. Boggs
- Department of Biological Sciences, University of Delaware, Newark, DE, USA
| | - R.L. Duncan
- Department of Biological Sciences, University of Delaware, Newark, DE, USA,Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
| | - R.L. Mauck
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA,Department of Orthopaedic Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - D.M. Elliott
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA,Address for correspondence: Dawn M. Elliott, Biomedical Engineering, University of Delaware, 125 E. Delaware Ave., Newark, DE 19716, USA, Telephone Number: 1-302-831-1295,
| |
Collapse
|
87
|
Jayyosi C, Fargier G, Coret M, Bruyère-Garnier K. Photobleaching as a tool to measure the local strain field in fibrous membranes of connective tissues. Acta Biomater 2014; 10:2591-601. [PMID: 24568925 DOI: 10.1016/j.actbio.2014.02.031] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2013] [Revised: 02/10/2014] [Accepted: 02/14/2014] [Indexed: 12/16/2022]
Abstract
Connective tissues are complex structures which contain collagen and elastin fibers. These fiber-based structures have a great influence on material mechanical properties and need to be studied at the microscopic scale. Several microscopy techniques have been developed in order to image such microstructures; among them are two-photon excited fluorescence microscopy and second harmonic generation. These observations have been coupled with mechanical characterization to link microstructural kinematics to macroscopic material parameter evolution. In this study, we present a new approach to measure local strain in soft biological tissues using a side-effect of fluorescence microscopy: photobleaching. Controlling the loss of fluorescence induced by photobleaching, we create a pattern on our sample that we can monitor during mechanical loading. The image analysis allows three-dimensional displacements of the patterns at various loading levels to be computed. Then, local strain distribution is derived using the finite element discretization on a four-node element mesh created from our photobleached pattern. Photobleaching tests on a human liver capsule have revealed that this technique is non-destructive and does not have any impact on mechanical properties. This method is likely to have other applications in biological material studies, considering that all collagen-elastin fiber-based biological tissues possess autofluorescence properties and thus can be photobleached.
Collapse
Affiliation(s)
- C Jayyosi
- Université de Lyon, F-69622 Lyon;IFSTTAR, LBMC, UMR-T9406; Université Lyon 1, France.
| | - G Fargier
- Plateforme IVTV, CNRS, 36 Avenue Guy de Collongue, Bâtiment G8, 69134 Ecully Cedex, France
| | - M Coret
- LUNAM Université, GEM, UMR CNRS 6183, Ecole Centrale de Nantes, Université de Nantes, France
| | - K Bruyère-Garnier
- Université de Lyon, F-69622 Lyon;IFSTTAR, LBMC, UMR-T9406; Université Lyon 1, France
| |
Collapse
|
88
|
Szczesny SE, Elliott DM. Interfibrillar shear stress is the loading mechanism of collagen fibrils in tendon. Acta Biomater 2014; 10:2582-90. [PMID: 24530560 DOI: 10.1016/j.actbio.2014.01.032] [Citation(s) in RCA: 104] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2013] [Revised: 12/04/2013] [Accepted: 01/30/2014] [Indexed: 12/15/2022]
Abstract
Despite the critical role tendons play in transmitting loads throughout the musculoskeletal system, little is known about the microstructural mechanisms underlying their mechanical function. Of particular interest is whether collagen fibrils in tendon fascicles bear load independently or if load is transferred between fibrils through interfibrillar shear forces. We conducted multiscale experimental testing and developed a microstructural shear lag model to explicitly test whether interfibrillar shear load transfer is indeed the fibrillar loading mechanism in tendon. Experimental correlations between fascicle macroscale mechanics and microscale interfibrillar sliding suggest that fibrils are discontinuous and share load. Moreover, for the first time, we demonstrate that a shear lag model can replicate the fascicle macroscale mechanics as well as predict the microscale fibrillar deformations. Since interfibrillar shear stress is the fundamental loading mechanism assumed in the model, this result provides strong evidence that load is transferred between fibrils in tendon and possibly other aligned collagenous tissues. Conclusively establishing this fibrillar loading mechanism and identifying the involved structural components should help develop repair strategies for tissue degeneration and guide the design of tissue engineered replacements.
Collapse
Affiliation(s)
- Spencer E Szczesny
- Department of Bioengineering, University of Pennsylvania, 240 Skirkanich Hall, 210 South 33rd St, Philadelphia, PA 19104, USA
| | - Dawn M Elliott
- Department of Biomedical Engineering, University of Delaware, 125 East Delaware Avenue, Newark, DE 19716, USA.
| |
Collapse
|
89
|
Han WM, Heo SJ, Driscoll TP, Smith LJ, Mauck RL, Elliott DM. Macro- to microscale strain transfer in fibrous tissues is heterogeneous and tissue-specific. Biophys J 2014; 105:807-17. [PMID: 23931328 DOI: 10.1016/j.bpj.2013.06.023] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2013] [Revised: 05/22/2013] [Accepted: 06/05/2013] [Indexed: 01/14/2023] Open
Abstract
Mechanical deformation applied at the joint or tissue level is transmitted through the macroscale extracellular matrix to the microscale local matrix, where it is transduced to cells within these tissues and modulates tissue growth, maintenance, and repair. The objective of this study was to investigate how applied tissue strain is transferred through the local matrix to the cell and nucleus in meniscus, tendon, and the annulus fibrosus, as well as in stem cell-seeded scaffolds engineered to reproduce the organized microstructure of these native tissues. To carry out this study, we developed a custom confocal microscope-mounted tensile testing device and simultaneously monitored strain across multiple length scales. Results showed that mean strain was heterogeneous and significantly attenuated, but coordinated, at the local matrix level in native tissues (35-70% strain attenuation). Conversely, freshly seeded scaffolds exhibited very direct and uniform strain transfer from the tissue to the local matrix level (15-25% strain attenuation). In addition, strain transfer from local matrix to cells and nuclei was dependent on fiber orientation and tissue type. Histological analysis suggested that different domains exist within these fibrous tissues, with most of the tissue being fibrous, characterized by an aligned collagen structure and elongated cells, and other regions being proteoglycan (PG)-rich, characterized by a dense accumulation of PGs and rounder cells. In meniscus, the observed heterogeneity in strain transfer correlated strongly with cellular morphology, where rounder cells located in PG-rich microdomains were shielded from deformation, while elongated cells in fibrous microdomains deformed readily. Collectively, these findings suggest that different tissues utilize distinct strain-attenuating mechanisms according to their unique structure and cellular phenotype, and these differences likely alter the local biologic response of such tissues and constructs in response to mechanical perturbation.
Collapse
Affiliation(s)
- Woojin M Han
- Department of Bioengineering, Perelman School of Medicine, University of Pennsylvania, Philadelphia, USA
| | | | | | | | | | | |
Collapse
|
90
|
Thorpe CT, Riley GP, Birch HL, Clegg PD, Screen HRC. Fascicles from energy-storing tendons show an age-specific response to cyclic fatigue loading. J R Soc Interface 2014; 11:20131058. [PMID: 24402919 DOI: 10.1098/rsif.2013.1058] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Some tendons, such as the human Achilles and equine superficial digital flexor tendon (SDFT), act as energy stores, stretching and recoiling to increase efficiency during locomotion. Our previous observations of rotation in response to applied strain in SDFT fascicles suggest a helical structure, which may provide energy-storing tendons with a greater ability to extend and recoil efficiently. Despite this specialization, energy-storing tendons are prone to age-related tendinopathy. The aim of this study was to assess the effect of cyclic fatigue loading (FL) on the microstructural strain response of SDFT fascicles from young and old horses. The data demonstrate two independent age-related mechanisms of fatigue failure; in young horses, FL caused low levels of matrix damage and decreased rotation. This suggests that loading causes alterations to the helix substructure, which may reduce their ability to recoil and recover. By contrast, fascicles from old horses, in which the helix is already compromised, showed greater evidence of matrix damage and suffer increased fibre sliding after FL, which may partially explain the age-related increase in tendinopathy. Elucidation of helix structure and the precise alterations occurring owing to both ageing and FL will help to develop appropriate preventative and repair strategies for tendinopathy.
Collapse
Affiliation(s)
- Chavaunne T Thorpe
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, , Mile End Road, London E1 4NS, UK
| | | | | | | | | |
Collapse
|
91
|
Filius A, Thoreson AR, Yang TH, Vanhees M, An KN, Zhao C, Amadio PC. The effect of low- and high-velocity tendon excursion on the mechanical properties of human cadaver subsynovial connective tissue. J Orthop Res 2014; 32:123-8. [PMID: 24038298 PMCID: PMC3845004 DOI: 10.1002/jor.22489] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2013] [Accepted: 08/20/2013] [Indexed: 02/04/2023]
Abstract
Fibrosis of the subsynovial connective tissue (SSCT) in the carpal tunnel is the most common histological finding in carpal tunnel syndrome (CTS). Fibrosis may result from damaged SSCT. Previous studies found that with low-velocity (2 mm/s), tendon excursions can irreversibly damage the SSCT. We investigated the effect of tendon excursion velocity in the generation of SSCT damage. Nine human cadaver wrists were used. Three repeated cycles of ramp-stretch testing were performed simulating 40%, 60%, 90%, and 120% of the middle finger flexor tendon superficialis physiological excursion with an excursion velocity of 60 mm/s. Energy and force were calculated and normalized by values obtained in the first cycle for each excursion level. Data were compared with low-velocity excursion data. For high-velocity excursions, a significant drop in the excursion energy ratio was first observed at an excursion level of 60% physiological excursion (p < 0.024) and that for low-velocity excursions was first observed at 90% physiological excursion (p < 0.038). Furthermore, the energy ratio was lower at 60% for high velocities (p ≤ 0.039). Increasing velocity lowers the SSCT damage threshold. This finding may be relevant for understanding the pathogenesis of SSCT fibrosis, such as that accompanying CTS, and a relationship with occupational factors.
Collapse
Affiliation(s)
- Anika Filius
- Biomechanics Laboratory and Tendon and Soft Tissue Biology Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester, MN 55905 USA,Department of Plastic, Reconstructive and Hand Surgery, Erasmus Medical Center, Rotterdam, the Netherlands,Department of Rehabilitation Medicine and Physical Therapy, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Andrew R. Thoreson
- Biomechanics Laboratory and Tendon and Soft Tissue Biology Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester, MN 55905 USA
| | - Tai-Hua Yang
- Biomechanics Laboratory and Tendon and Soft Tissue Biology Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester, MN 55905 USA
| | - Matthias Vanhees
- Biomechanics Laboratory and Tendon and Soft Tissue Biology Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester, MN 55905 USA
| | - Kai-Nan An
- Biomechanics Laboratory and Tendon and Soft Tissue Biology Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester, MN 55905 USA
| | - Chunfeng Zhao
- Biomechanics Laboratory and Tendon and Soft Tissue Biology Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester, MN 55905 USA
| | - Peter C. Amadio
- Biomechanics Laboratory and Tendon and Soft Tissue Biology Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester, MN 55905 USA
| |
Collapse
|
92
|
Smith R, McIlwraith W, Schweitzer R, Kadler K, Cook J, Caterson B, Dakin S, Heinegård D, Screen H, Stover S, Crevier-Denoix N, Clegg P, Collins M, Little C, Frisbie D, Kjaer M, van Weeren R, Werpy N, Denoix JM, Carr A, Goldberg A, Bramlage L, Smith M, Nixon A. Advances in the understanding of tendinopathies: A report on the Second Havemeyer Workshop on equine tendon disease. Equine Vet J 2013; 46:4-9. [DOI: 10.1111/evj.12128] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Affiliation(s)
- R. Smith
- Department of Veterinary Clinical Sciences and Services; The Royal Veterinary College; UK
| | - W. McIlwraith
- Clinical Sciences; Orthopaedic Research Center; Colorado State University; USA
| | - R. Schweitzer
- SOM-Cell and Developmental Biology Department; Oregon Health and Science University; USA
| | - K. Kadler
- Faculty of Life Sciences; University of Manchester; UK
| | - J. Cook
- Department of Physiotherapy; School of Primary Health Care; Monash University; Victoria Australia
| | | | - S. Dakin
- Department of Veterinary Clinical Sciences and Services; The Royal Veterinary College; UK
| | | | - H. Screen
- The School of Engineering and Materials Science; Queen Mary, University of London; UK
| | | | - N. Crevier-Denoix
- Ecole Vétérinaire d'Alfort; UMR INRA-ENVA BPLC (Biomécanique du Cheval); France
| | | | - M. Collins
- Department of Human Biology; UCT/MRC Research Unit for Exercise Science and Sports Medicine (ESSM); South Africa
| | - C. Little
- Raymond Purves Bone and Joint Research Laboratories; Kolling Institute of Medical Research; E25 - Royal North Shore Hospital; University of Sydney; New South Wales Australia
| | - D. Frisbie
- Clinical Sciences; Colorado State University; USA
| | - M. Kjaer
- Department of Clinical Medicine; Section of Orthopaedics and Internal Medicine; Bispejerg Hospital; Denmark
| | - R. van Weeren
- Equine Sciences; Utrecht University; the Netherlands
| | - N. Werpy
- Veterinary Medicine and Surgery; University of Florida; USA
| | | | - A. Carr
- Nuffield Department of Orthopaedics; Rheumatology and Musculoskeletal Sciences; Nuffield Orthopaedic Centre; University of Oxford; UK
| | | | - L. Bramlage
- Rood and Riddle Equine Hospital; Kentucky USA
| | | | - A. Nixon
- Clinical Sciences; Cornell University; New York USA
| |
Collapse
|
93
|
Veres SP, Harrison JM, Lee JM. Cross-link stabilization does not affect the response of collagen molecules, fibrils, or tendons to tensile overload. J Orthop Res 2013; 31:1907-13. [PMID: 24038530 DOI: 10.1002/jor.22460] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2013] [Accepted: 07/15/2013] [Indexed: 02/04/2023]
Abstract
We investigated whether immature allysine-derived cross-links provide mechanically labile linkages by exploring the effects of immature cross-link stabilization at three levels of collagen hierarchy: damaged fibril morphology, whole tendon mechanics, and molecular stability. Tendons from the tails of young adult steers were either treated with sodium borohydride (NaBH₄) to stabilize labile cross-links, exposed only to the buffer used during stabilization treatment, or maintained as untreated controls. One-half of each tendon was then subjected to five cycles of subrupture overload. Morphologic changes to collagen fibrils resulting from overload were investigated using scanning electron microscopy, and changes in the hydrothermal stability of collagen molecules were assessed using hydrothermal isometric tension testing. NaBH4 cross-link stabilization did not affect the response of tendon collagen to tensile overload at any of the three levels of hierarchy studied. Cross-link stabilization did not prevent the characteristic overload-induced mode of fibril damage that we term discrete plasticity. Similarly, stabilization did not alter the mechanical response of whole tendons to overload, and did not prevent an overload-induced thermal destabilization of collagen molecules. Our results indicate that hydrothermally labile cross-links may not be as mechanically labile as was previously thought.
Collapse
Affiliation(s)
- Samuel P Veres
- Division of Engineering, Saint Mary's University, Halifax, Nova Scotia, Canada, B3H 3C3
| | | | | |
Collapse
|
94
|
Shepherd JH, Legerlotz K, Demirci T, Klemt C, Riley GP, Screen HRC. Functionally distinct tendon fascicles exhibit different creep and stress relaxation behaviour. Proc Inst Mech Eng H 2013; 228:49-59. [PMID: 24285289 PMCID: PMC4361498 DOI: 10.1177/0954411913509977] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Most overuse tendinopathies are thought to be associated with repeated microstrain below the failure threshold, analogous to the fatigue failure that affects materials placed under repetitive loading. Investigating the progression of fatigue damage within tendons is therefore of critical importance. There are obvious challenges associated with the sourcing of human tendon samples for in vitro analysis so animal models are regularly adopted. However, data indicates that fatigue life varies significantly between tendons of different species and with different stresses in life. Positional tendons such as rat tail tendon or the bovine digital extensor are commonly applied in in vitro studies of tendon overuse, but there is no evidence to suggest their behaviour is indicative of the types of human tendon particularly prone to overuse injuries. In this study, the fatigue response of the largely positional digital extensor and the more energy storing deep digital flexor tendon of the bovine hoof were compared to the semitendinosus tendon of the human hamstring. Fascicles from each tendon type were subjected to either stress or strain controlled fatigue loading (cyclic creep or cyclic stress relaxation respectively). Gross fascicle mechanics were monitored after cyclic stress relaxation and the mean number of cycles to failure investigated with creep loading. Bovine extensor fascicles demonstrated the poorest fatigue response, while the energy storing human semitendinosus was the most fatigue resistant. Despite the superior fatigue response of the energy storing tendons, confocal imaging suggested a similar degree of damage in all three tendon types; it appears the more energy storing tendons are better able to withstand damage without detriment to mechanics.
Collapse
Affiliation(s)
- Jennifer H Shepherd
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary, University of London, London, UK
| | | | | | | | | | | |
Collapse
|
95
|
Massoud EIE. Healing of subcutaneous tendons: Influence of the mechanical environment at the suture line on the healing process. World J Orthop 2013; 4:229-240. [PMID: 24147258 PMCID: PMC3801242 DOI: 10.5312/wjo.v4.i4.229] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2013] [Accepted: 08/29/2013] [Indexed: 02/06/2023] Open
Abstract
Tendon ruptures remain a significant musculoskeletal injury. Despite advances in surgical techniques and procedures, traditional repair techniques maintain a high incidence of rerupture or tendon elongation. Mechanical loading and biochemical signaling both control tissue healing. This has led some researchers to consider using a technique based on tension regulation at the suture line for obtaining good healing. However, it is unknown how they interact and to what extent mechanics control biochemistry. This review will open the way for understanding the interplay between mechanical loading and the process of tendon healing.
Collapse
|
96
|
Shepherd JH, Screen HRC. Fatigue loading of tendon. Int J Exp Pathol 2013; 94:260-70. [PMID: 23837793 DOI: 10.1111/iep.12037] [Citation(s) in RCA: 61] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2013] [Accepted: 06/12/2013] [Indexed: 12/28/2022] Open
Abstract
Tendon injuries, often called tendinopathies, are debilitating and painful conditions, generally considered to develop as a result of tendon overuse. The aetiology of tendinopathy remains poorly understood, and whilst tendon biopsies have provided some information concerning tendon appearance in late-stage disease, there is still little information concerning the mechanical and cellular events associated with disease initiation and progression. Investigating this in situ is challenging, and numerous models have been developed to investigate how overuse may generate tendon fatigue damage and how this may relate to tendinopathy conditions. This article aims to review these models and our current understanding of tendon fatigue damage. We review the strengths and limitations of different methodologies for characterizing tendon fatigue, considering in vitro methods that adopt both viable and non-viable samples, as well as the range of different in vivo approaches. By comparing data across model systems, we review the current understanding of fatigue damage development. Additionally, we compare these findings with data from tendinopathic tissue biopsies to provide some insights into how these models may relate to the aetiology of tendinopathy. Fatigue-induced damage consistently highlights the same microstructural, biological and mechanical changes to the tendon across all model systems and also correlates well with the findings from tendinopathic biopsy tissue. The multiple testing routes support matrix damage as an important contributor to tendinopathic conditions, but cellular responses to fatigue appear complex and often contradictory.
Collapse
Affiliation(s)
- Jennifer H Shepherd
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary, University of London, London E1 4NS, UK.
| | | |
Collapse
|
97
|
Schmidt H, Galbusera F, Rohlmann A, Shirazi-Adl A. What have we learned from finite element model studies of lumbar intervertebral discs in the past four decades? J Biomech 2013; 46:2342-55. [PMID: 23962527 DOI: 10.1016/j.jbiomech.2013.07.014] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2013] [Revised: 07/05/2013] [Accepted: 07/07/2013] [Indexed: 12/28/2022]
Abstract
Finite element analysis is a powerful tool routinely used to study complex biological systems. For the last four decades, the lumbar intervertebral disc has been the focus of many such investigations. To understand the disc functional biomechanics, a precise knowledge of the disc mechanical, structural and biochemical environments at the microscopic and macroscopic levels is essential. In response to this need, finite element model studies have proven themselves as reliable and robust tools when combined with in vitro and in vivo measurements. This paper aims to review and discuss some salient findings of reported finite element simulations of lumbar intervertebral discs with special focus on their relevance and implications in disc functional biomechanics. Towards this goal, the earlier investigations are presented, discussed and summarized separately in three distinct groups of elastic, multi-phasic transient and transport model studies. The disc overall response as well as the relative role of its constituents are markedly influenced by loading rate, magnitude, combinations/preloads and posture. The nucleus fluid content and pressurizing capacity affect the disc compliance, annulus strains and failure sites/modes. Biodynamics of the disc is affected by not only the excitation characteristics but also preloads, existing mass and nucleus condition. The role of fluid pressurization and collagen fiber stiffening diminish with time during diurnal loading. The endplates permeability influences the time-dependent response of the disc in both loaded and unloaded recovery phases. The transport of solutes is substantially influenced by the disc size, tissue diffusivity and endplates permeability.
Collapse
Affiliation(s)
- Hendrik Schmidt
- Julius Wolff Institut, Charité - Universitätsmedizin Berlin, Berlin, Germany.
| | | | | | | |
Collapse
|
98
|
Helical sub-structures in energy-storing tendons provide a possible mechanism for efficient energy storage and return. Acta Biomater 2013; 9:7948-56. [PMID: 23669621 DOI: 10.1016/j.actbio.2013.05.004] [Citation(s) in RCA: 92] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2013] [Revised: 04/18/2013] [Accepted: 05/02/2013] [Indexed: 12/26/2022]
Abstract
The predominant function of tendons is to position the limb during locomotion. Specific tendons also act as energy stores. Energy-storing (ES) tendons are prone to injury, the incidence of which increases with age. This is likely related to their function; ES tendons are exposed to higher strains and require a greater ability to recoil than positional tendons. The specialized properties of ES tendons are thought to be achieved through structural and compositional differences. However, little is known about structure-function relationships in tendons. This study uses fascicles from the equine superficial digital flexor (SDFT) and common digital extensor (CDET) as examples of ES and positional tendons. We hypothesized that extension and recoil behaviour at the micro-level would differ between tendon types, and would alter with age in the injury-prone SDFT. Supporting this, the results show that extension in the CDET is dominated by fibre sliding. By contrast, greater rotation was observed in the SDFT, suggesting a helical component to fascicles in this tendon. This was accompanied by greater recovery and less hysteresis loss in SDFT samples. In samples from aged SDFTs, the amount of rotation and the ability to recover decreased, while hysteresis loss increased. These findings indicate that fascicles in the ES SDFT may have a helical structure, enabling the more efficient recoil observed. Further, the helix structure appears to alter with ageing; this coincides with a reduction in the ability of SDFT fascicles to recoil. This may affect tendon fatigue resistance and predispose aged tendons to injury.
Collapse
|
99
|
Bosworth LA, Alam N, Wong JK, Downes S. Investigation of 2D and 3D electrospun scaffolds intended for tendon repair. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2013; 24:1605-1614. [PMID: 23504088 DOI: 10.1007/s10856-013-4911-8] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2013] [Accepted: 03/08/2013] [Indexed: 06/01/2023]
Abstract
Two-dimensional (2D) electrospun fibre mats have been investigated as fibrous sheets intended as biomaterials scaffolds for tissue repair. It is recognised that tissues are three-dimensional (3D) structures and that optimisation of the fabrication process should include both 2D and 3D scaffolds. Understanding the relative merits of the architecture of 2D and 3D scaffolds for tendon repair is required. This study investigated three different electrospun scaffolds based on poly(ε-caprolactone) fibres intended for repair of injured tendons, referred to as; 2D random sheet, 2D aligned sheet and 3D bundles. 2D aligned fibres and 3D bundles mimicked the parallel arrangement of collagen fibres in natural tendon and 3D bundles further replicated the tertiary layer of a tendon's hierarchical configuration. 3D bundles demonstrated greatest tensile properties, being significantly stronger and stiffer than 2D aligned and 2D random fibres. All scaffolds supported adhesion and proliferation of tendon fibroblasts. Furthermore, 2D aligned sheets and 3D bundles allowed guidance of the cells into a parallel, longitudinal arrangement, which is similar to tendon cells in the native tissue. With their superior physical properties and ability to better replicate tendon tissue, the 3D electrospun scaffolds warrant greater investigation as synthetic grafts in tendon repair.
Collapse
Affiliation(s)
- L A Bosworth
- School of Materials, Materials Science Centre, The University of Manchester, Grosvenor Street, Manchester M1 7HS, UK.
| | | | | | | |
Collapse
|
100
|
Birch HL, Thorpe CT, Rumian AP. Specialisation of extracellular matrix for function in tendons and ligaments. Muscles Ligaments Tendons J 2013; 3:12-22. [PMID: 23885341 DOI: 10.11138/mltj/2013.3.1.012] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Tendons and ligaments are similar structures in terms of their composition, organisation and mechanical properties. The distinction between them stems from their anatomical location; tendons form a link between muscle and bone while ligaments link bones to bones. A range of overlapping functions can be assigned to tendon and ligaments and each structure has specific mechanical properties which appear to be suited for particular in vivo function. The extracellular matrix in tendon and ligament varies in accordance with function, providing appropriate mechanical properties. The most useful framework in which to consider extracellular matrix differences therefore is that of function rather than anatomical location. In this review we discuss what is known about the relationship between functional requirements, structural properties from molecular to gross level, cellular gene expression and matrix turnover. The relevance of this information is considered by reviewing clinical aspects of tendon and ligament repair and reconstructive procedures.
Collapse
Affiliation(s)
- Helen L Birch
- Institute of Orthopaedics and Musculoskeletal Science, University College London, RNOH, Brockley Hill, Stanmore, U.K
| | | | | |
Collapse
|