51
|
Zhang H, Li H, Cong Q, Zhang Z, Du A, Wang Y. Effect of proximal box elevation on fracture resistance and microleakage of premolars restored with ceramic endocrowns. PLoS One 2021; 16:e0252269. [PMID: 34038489 PMCID: PMC8153463 DOI: 10.1371/journal.pone.0252269] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Accepted: 05/13/2021] [Indexed: 11/19/2022] Open
Abstract
Background Restoration of endodontically treated premolar is in high risk for biomechanical failure, and often presents with subgingival margins. Proximal box elevation (PBE) has been used to relocate subgingival cavity outlines. Objective To evaluate the influence of PBE on fracture resistance and gingival microleakage of premolars with endodontic access cavities following ceramic endocrown. Methods Eighty sound maxillary premolars with standardized Class II cavities on mesial surfaces were randomly assigned to four groups (n = 20 in each group). Groups E1, E2 and E3, with proximal margins located in dentin/cementum, 2 mm below the cemento-enamel junction (CEJ), simulated subgingival location. Group E4 (supragingival group), with proximal margins located in enamel, 1 mm above the CEJ, was used as the positive control. For margin elevation of the proximal cavities, bulk-fill Smart Dentin Replacement (SDR), a visible light cured resin composite, was applied in group E1, and conventional resin composite (3M Z350 XT, a light-activated composite) was placed in group E2. Group E3 was only treated with a ceramic crown and served as the negative control. In all groups, computer-aided design (CAD) ceramic endocrowns were adhesively inserted, and fracture resistance, failure mode and microleakage were evaluated. Results A higher fracture resistance value was observed in PBE groups E1 and E2, regardless of the materials used (P = 0.038, and 0.010, respectively, vs E3), and fracture resistance in group E1 was higher than that in group E2. In teeth without PBE, the percentage of catastrophic failures reached 70%. Compared to group E3, a lower frequency distribution of microleakage was detected in supragingival group E4 (P = 0.031). No increased percentage of microleakage was observed in groups treated with PBE. Conclusion For endodontically treated maxillary premolars restored with ceramic endocrowns, PBE increases fracture resistance but not microleakage.
Collapse
Affiliation(s)
- Hong Zhang
- Hospital of Stomatology, Jilin University, Changchun, P.R China
| | - He Li
- Hospital of Stomatology, Jilin University, Changchun, P.R China
| | - Qian Cong
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, P.R China
| | - Zhimin Zhang
- Hospital of Stomatology, Jilin University, Changchun, P.R China
- * E-mail:
| | - Aobo Du
- Hospital of Stomatology, Jilin University, Changchun, P.R China
| | - Ying Wang
- Hospital of Stomatology, Jilin University, Changchun, P.R China
| |
Collapse
|
52
|
Albelasy E, Hamama HH, Tsoi JKH, Mahmoud SH. Influence of material type, thickness and storage on fracture resistance of CAD/CAM occlusal veneers. J Mech Behav Biomed Mater 2021; 119:104485. [PMID: 33812289 DOI: 10.1016/j.jmbbm.2021.104485] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Revised: 03/09/2021] [Accepted: 03/15/2021] [Indexed: 11/16/2022]
Abstract
OBJECTIVES The present study aimed to evaluate the effect of restoration thickness, CAD/CAM material, and 6 months of artificial saliva storage on the fracture resistance of occlusal veneers. MATERIALS AND METHODS A total of 84 intact maxillary molars were sectioned 4.0 mm occlusal to the cementoenamel junction to expose the dentine. The teeth were assigned into 3 main groups according to the type of restorative material (e.max CAD, Vita Enamic, and Lava Ultimate). In each group, the teeth were allocated into 2 subgroups (n = 14) according to restoration thickness (1.0 and 1.5 mm). The veneers were adhesively bonded using dual-cure self-adhesive luting agent. A total of 42 specimens comprising half the tested subgroups were stored in distilled water for 24-h before the test. The remaining half was stored in artificial saliva at 37 ± 1 °C in an incubator for 6 months. All specimens (n = 84) were subjected to 5000 thermal cycles between 5 and 55 °C ± 2 before the fracture resistance test. The maximum force at fracture was recorded in Newton. Failure mode was analyzed using a stereomicroscope. The results were analyzed using a parametric Three-way ANOVA test. RESULTS The results of the Three-way ANOVA test revealed that material type and restoration thickness significantly affected fracture resistance values (p < 0.5), while 6 months of storage in artificial saliva had no significant effect on mean fracture resistance values (p˃0.5). The most common failure patterns in CAD/CAM resin composite and polymer-infiltrated ceramics were scores I and score II. For glass ceramic groups, score IV and III were more dominant. CONCLUSIONS All the tested CAD/CAM restorations in both thicknesses exhibited fracture resistance values exceeding normal and parafunctional bite forces. Polymer-infiltrated ceramics and CAD/CAM resin composite veneers showed more favorable fracture patterns.
Collapse
Affiliation(s)
- Eman Albelasy
- Operative Dentistry Department, Faculty of Dentistry, Mansoura University, Egypt
| | - Hamdi H Hamama
- Operative Dentistry Department, Faculty of Dentistry, Mansoura University, Egypt.
| | - James K H Tsoi
- Dental Material Science, Division of Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong, China
| | - Salah H Mahmoud
- Operative Dentistry Department, Faculty of Dentistry, Mansoura University, Egypt
| |
Collapse
|
53
|
Albelasy EH, Hamama HH, Tsoi JK, Mahmoud SH. Fracture resistance of CAD/CAM occlusal veneers: A systematic review of laboratory studies. J Mech Behav Biomed Mater 2020; 110:103948. [DOI: 10.1016/j.jmbbm.2020.103948] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 06/18/2020] [Accepted: 06/21/2020] [Indexed: 11/27/2022]
|
54
|
Sağlam G, Cengiz S, Karacaer Ö. Marginal adaptation and fracture strength of endocrowns manufactured with different restorative materials: SEM and mechanical evaluation. Microsc Res Tech 2020; 84:284-290. [PMID: 32915479 DOI: 10.1002/jemt.23586] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 08/06/2020] [Accepted: 08/17/2020] [Indexed: 11/08/2022]
Abstract
Endocrowns were manufactured using different restorative materials to evaluate the marginal adaptation and fracture strength. Fifty endodontically treated mandibular first molar teeth were divided into five groups (n = 10). Endocrowns were obtained from lithium disilicate glass ceramic ingots by heat-press technique (Group e.max Press: GEP), and from feldspathic blocks (Group Cerec: GC), polymer infiltrated ceramic network blocks (Group Enamic: GE), lithium disilicate glass ceramic blocks (Group e.max CAD: GEC), and zirconia-reinforced glass ceramic blocks (Group Suprinity: GS) by CAD/CAM technique. After thermocycling, marginal adaptation was evaluated under scanning electron microscope at ×200 magnification. The specimens' fracture strengths were tested in universal test machine, and fracture types were evaluated. Statistical analyses were performed with Kruskal-Wallis test. The highest marginal gap value was found in GEP, but no significant differences were determined among the other four groups (p > .05). Significant differences were observed among the groups in terms of fracture strength (p = .019). The fracture strength values of GEC were significantly higher than GE, GC, and GS (p < .05). Values were not significantly different between the GEC and GEP groups (p > .05). CAD/CAM endocrowns showed better marginal adaptation than heat-pressed endocrowns. Clinically acceptable marginal gaps were seen in both endocrown types. Both CAD/CAM and heat-pressed lithium disilicate glass ceramic endocrowns showed higher fracture strength.
Collapse
Affiliation(s)
- Gaye Sağlam
- Department of Prosthodontics, Faculty of Dentistry, Zonguldak Bülent Ecevit University, Zonguldak, Turkey
| | - Seda Cengiz
- Department of Prosthodontics, Faculty of Dentistry, Zonguldak Bülent Ecevit University, Zonguldak, Turkey
| | - Özgül Karacaer
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara, Turkey
| |
Collapse
|
55
|
Elashmawy Y, Elshahawy W, Seddik M, Aboushelib M. Influence of fatigue loading on fracture resistance of endodontically treated teeth restored with endocrowns. J Prosthodont Res 2020; 65:78-85. [PMID: 32938873 DOI: 10.2186/jpr.jpor_2019_485] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE This in vitro study aimed to evaluate the influence of fatigue loading on fracture resistance of endodontically treated molars restored with endocrowns using different machinable blocks. METHODS Endodontically treated mandibular first molars were prepared using a standardized method. Specimens were divided into 4 groups (n = 10).Anatomically shaped endocrowns groups were manufactured using VITA ENAMIC (VE) and KATANA Zirconia (KZ). Layered endocrowns groups were manufactured using IPS e.max CAD (EM) and BioHPP (BH). Half of the specimens of each group were subjected to fracture resistance test, while the other half were subjected to thermocycling and chewing simulation. After fatigue loading, specimens were loaded until failure. Specimens were examined using stereomicroscopy. Data were analyzed using ANOVA analysis of variance and Bonferroni post hoc test (α=0.05). RESULTS KZ group had the highest initial fracture resistance value (1810.20± 119.56 N) and BH had the lowest value (579.50± 76.15 N). The reduction of fracture resistance after fatigue loading was significant for KZ group (1588.30±216.25 N) and BH group (502.60±11.53 N) and non-significant to VE group (1101.70±77.05 N) and EM group (1112.10±74.12 N). Failure modes of KZ and EM groups showed high percentage of non-restorable fractures, while VE and BH groups showed high percentage of restorable fractures. CONCLUSIONS Within the limitations of this study, the following can be concluded: Poly infiltrated ceramics should be considered as a proper material to be used as an endocrown material because of its ability to be restorable if failure occurred.
Collapse
Affiliation(s)
- Yasmin Elashmawy
- Department of Fixed Prosthodontics, University of Tanta Faculty of dentistry, Tanta
| | - Waleed Elshahawy
- Department of Fixed Prosthodontics, University of Tanta Faculty of dentistry, Tanta
| | - Mohamed Seddik
- Department of Fixed Prosthodontics, University of Tanta Faculty of dentistry, Tanta
| | - Moustafa Aboushelib
- Department of Dental Materials, University of Alexandria Faculty of dentistry, Alexandria
| |
Collapse
|
56
|
Hassouneh L, Jum’ah AA, Ferrari M, Wood DJ. Post-fatigue fracture resistance of premolar teeth restored with endocrowns: An in vitro investigation. J Dent 2020; 100:103426. [DOI: 10.1016/j.jdent.2020.103426] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 06/30/2020] [Accepted: 07/02/2020] [Indexed: 11/16/2022] Open
|
57
|
Lin J, Lin Z, Zheng Z. Effect of different restorative crown design and materials on stress distribution in endodontically treated molars: a finite element analysis study. BMC Oral Health 2020; 20:226. [PMID: 32811484 PMCID: PMC7437004 DOI: 10.1186/s12903-020-01214-3] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Accepted: 08/10/2020] [Indexed: 11/23/2022] Open
Abstract
Background The purposes of this simulation study were to evaluate the stresses in the roots of endodontically treated molars with extensive coronal tissue loss which were restored by endocrowns (all-in-one core and crown) and traditional crowns with post-cores, during masticatory simulation using finite element analysis. Methods A mesio-distal cross-section of a lower right first molar was digitized and used to create 2-dimensional models of the teeth and supporting tissue; different crown designs, viz., endocrown with 2 mm occlusal clearance, endocrown with 4 mm occlusal clearance and post-core crown; different crown materials, viz., zirconia (Zr) and lithia-disilicate reinforced glass ceramic (LDRGC), and different post and core materials, viz., glass fiber (GF), stainless steel (SS) and metal cast (MC). An axial load of 600 N was applied to the central fossa of occlusal surface. Results The stress distributions were similar between Zr and LDRGC for periodontal ligament and alveolar bone. The root canal inner wall maximum principal stresses of SS post (70.8 MPa) and MC post (71.4 MPa) were higher than that of GF post (36.0 MPa) and endocrown (2.4 MPa). Conclusion The endocrowns reduced stress concentration for the root canal inner wall in comparison with the conventional post-core crown. Molars restored with endocrowns are less prone to root fracture than those with posts.
Collapse
Affiliation(s)
- Jie Lin
- Fujian Key Laboratory of Oral Diseases, School and Hospital of Stomatology, Fujian Medical University, 246 Yangqiao Zhong Road, Fuzhou, Fujian, 350002, People's Republic of China.,Department of Crown and Bridge, School of Life Dentistry at Tokyo, The Nippon Dental University, 1-9-20 Fujimi, Chiyoda-ku, Tokyo, 102-8159, Japan
| | - Zhenxiang Lin
- Department of Stomatology, Hospital of Fujian Provincial Authorities, 68 Guping Road, Fuzhou, Fujian, 350001, People's Republic of China
| | - Zhiqiang Zheng
- Fujian Key Laboratory of Oral Diseases, School and Hospital of Stomatology, Fujian Medical University, 246 Yangqiao Zhong Road, Fuzhou, Fujian, 350002, People's Republic of China.
| |
Collapse
|
58
|
Biomechanical behavior of endocrown restorations with different CAD-CAM materials: A 3D finite element and in vitro analysis. J Prosthet Dent 2020; 125:890-899. [PMID: 32471627 DOI: 10.1016/j.prosdent.2020.03.009] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2019] [Revised: 03/01/2020] [Accepted: 03/02/2020] [Indexed: 11/21/2022]
Abstract
STATEMENT OF PROBLEM The performance of endocrowns fabricated with different types of computer-aided design and computer-aided manufacturing (CAD-CAM) materials is unclear. PURPOSE The purpose of this finite element analysis (FEA) and in vitro study was to compare and evaluate the stress distribution, failure probability, and fracture resistance of endodontically treated teeth restored with endocrowns from CAD-CAM milling blocks including ceramic, polymer-infiltrated ceramic (PICN), and composite resin. MATERIAL AND METHODS An endodontically treated first mandibular molar restored with an endocrown was modeled by using a CAD software program and imported into an FEA software program. The model was duplicated and received restorations made from CAD-CAM blocks: Vita Suprinity (VS), IPS e.max CAD (EMX), Vita Enamic (VE), Lava Ultimate (LU), and Grandio blocs (GR). Stress distributions under axial and oblique loading were analyzed. The Weibull function was combined with the FEA results to predict long-term failure probability. The mechanical failure behavior of endocrowns manufactured with these materials was tested by using a universal testing machine. Load-to-failure was recorded, and fractured specimens were subjected to fractography. The data were analyzed by 1-way ANOVA and the post hoc Tukey test (α=.05). RESULTS The models of GR and LU exhibited a more even stress distribution. The Weibull analysis revealed that 5 models performed in a similar manner under normal occlusal forces, while LU and VE models achieved the highest probabilities during clenching. The fracture loads of GR (3808 ±607 N) were significantly higher than those of other materials (P<.05). More favorable failure modes were observed in the GR and VE groups. Fractography showed a greater probability of compression curls and arrest lines in the endocrowns of VE, LU, and GR groups. CONCLUSIONS When restoring endodontically treated teeth, endocrown fabricated with composite resin exhibited a more uniform stress distribution and higher fracture resistance. More evidence from long-term clinical studies is needed to verify this effect.
Collapse
|
59
|
Dejak B, Młotkowski A. A comparison of mvM stress of inlays, onlays and endocrowns made from various materials and their bonding with molars in a computer simulation of mastication - FEA. Dent Mater 2020; 36:854-864. [PMID: 32473834 DOI: 10.1016/j.dental.2020.04.007] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2020] [Accepted: 04/14/2020] [Indexed: 12/13/2022]
Abstract
OBJECTIVES The purpose of the study was to compare the mvM stresses occurring in inlays, onlays and endocrowns made from different materials and their bonding with molars in a computer simulation of mastication. METHODS The study was conducted using the finite elements method with contact elements. Sixteen 3D first molar models were created of a intact tooth - T; a tooth with a ceramic inlay - IN; a tooth with an onlay - ON; and a tooth with an endocrown - EN. The restorations were made of: Comp - resin nanoceramic; Hc - hybrid ceramic; Le - leucite ceramic; Dlit - lithium disilicate; and Zr - zirconia. Computer simulations of mastication were performed. The equivalent stresses according to the modified von Mises criterion (mvM) were calculated in model materials and contact stresses at the interface cement-dental tissue around the examined restorations. RESULTS The highest equivalent mvM stresses were concentrated in buccal margins of inlays. The mvM stresses recorded in onlays were 1.6-5 times lower than those found in inlays, while in endocrowns they were 2.3-6.5 times lower. Around the onlays and endocrowns, in tooth structures and luting cement, mvM stresses were significantly lower compared to teeth restored with inlays. The tensile and shear contact stresses between inlays and teeth were several times lower than under another restorations. The highest stresses (58.5MPa) occurred in the zirconia inlay. The stresses observed in the enamel of a tooth restored with an INZr inlay were half those noted in INComp, and a third of those observed in cement. Tensile contact stresses at the interface between the INZr inlay and dental tissue were 4.5 times lower than in the INComp, and the shear stresses were more than 7 times lower. SIGNIFICANCE The highest values and unfavorable of stress levels occurred in teeth restored with inlays. Cavities MOD in molars should be reconstructed with cusp-covering restorations. The endocrown in molars should withstand physiological loading. The higher the modulus of elasticity of the restoration material, the higher the stresses in the restorations, while the lower stresses were observed in the tooth structures, luting cement and at the interface between the restoration and the dental tissue. Ceramic restorations should provide better protection and marginal seal of the reconstructed tooth than composite ones.
Collapse
Affiliation(s)
- Beata Dejak
- Department of Prosthetic Dentistry, Medical University of Łódź, Łódź, Poland.
| | - Andrzej Młotkowski
- Department of Strength of Materials and Structures, Technical University of Łódź, Łódź, Poland
| |
Collapse
|
60
|
Influence of Occlusal Thickness and Radicular Extension on the Fracture Resistance of Premolar Endocrowns from Different All-Ceramic Materials. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10082696] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Endocrowns are primarily recommended in a molar region with a standardized preparation design. The aim of the study was to evaluate the effect of different occlusal preparation depths, pulp chamber-radicular extension, and all-ceramic materials on the fracture resistance of premolar endocrowns. Ninety human premolar teeth were root canal treated, randomly divided into three main groups according to all-ceramic material used for fabrication as Lithium Disilicate (LD) ceramic, Polymer infiltrated ceramic (PIC) and High translucency zirconia (HTZ). They were further subdivided into three subgroups (n = 10) according to preparation design of 2 mm occlusal reduction, 4.5 mm occlusal reduction and 4.5 mm occlusal reduction with 2 mm radicular extension. The endocrowns from respective restorative materials were fabricated, surface conditioned, and cemented with self-adhesive resin cement. All samples were thermocycled for 5000 cycles and subjected to compressive static load at 45° angluation with the cross-head speed of 0.5 mm/minute until the fracture. The mean fracture resistance of LD ceramic at 2 mm, 4.5 mm thickness and radicular extension was 62.55 MPa, 45.80 MPa, 74.27 MPa respectively. The corresponding values for the PIC and HTZ ceramics were 26.30 MPa, 21.65 MPa, 25.66 Mpa and 23.47 MPa, 27.30 MPa, 37.29 MPa respectively. The LD ceramic and greater extension inside the pulp chamber had higher fracture resistance.
Collapse
|
61
|
Endocrowns: A systematic review. J Prosthet Dent 2020; 123:411-418.e9. [DOI: 10.1016/j.prosdent.2019.04.009] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Revised: 04/14/2019] [Accepted: 04/15/2019] [Indexed: 11/18/2022]
|
62
|
Turkistani AA, Dimashkieh M, Rayyan M. Fracture resistance of teeth restored with endocrowns: An in vitro study. J ESTHET RESTOR DENT 2019; 32:389-394. [PMID: 31743558 DOI: 10.1111/jerd.12549] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Accepted: 10/27/2019] [Indexed: 11/30/2022]
Abstract
OBJECTIVE The objective of this study is to evaluate the fracture resistance and failure mode of endodontically treated teeth restored with lithium disilicate endocrowns of different crown thicknesses. MATERIALS AND METHODS A total of 30 endodontically treated permanent mandibular first molars were sectioned horizontally 2 mm above the highest point of the cemento-enamel junction. The specimens were divided into three groups, and each group was restored with lithium disilicate (IPS e-max press) endocrowns of different crown thicknesses (3, 4.5, and 6 mm, respectively). After cementation, specimens were stored in room temperature for 72 hours, followed by subjecting them to compressive strength testing until failure. The fracture loads and the failure mode were recorded. Statistically analysis was performed using one-way analysis of variance. RESULTS A statistically significant difference was found in the fracture resistance between the three groups with the highest fracture resistance in the 3 mm group, followed by the 4.5 mm group, and the least in the 6 mm group (P < .05). Most of the failures were accompanied with tooth fracture (90% in 3 mm group, 100% in 4.5 mm group, and 80% in 6 mm group). CONCLUSIONS Increasing the crown thickness of the endocrowns reduced the fracture resistance of restored teeth. Minimum fracture loads for all teeth restored with endocrowns were significantly higher than the maximum occlusal forces reported in the literature. CLINICAL SIGNIFICANCE Fracture resistance and mode of failure of lithium disilicate (IPS e-max press) endocrowns varies widely between crown thicknesses. Clinicians should be cautious with crown thickness for endocrown restorations.
Collapse
Affiliation(s)
| | | | - Mohammed Rayyan
- Prosthodontic Department, Riyadh Elm University, Riyadh, Saudi Arabia
| |
Collapse
|
63
|
Tribst JPM, Dal Piva AMDO, Madruga CFL, Valera MC, Bresciani E, Bottino MA, de Melo RM. The impact of restorative material and ceramic thickness on CAD\CAM endocrowns. J Clin Exp Dent 2019; 11:e969-e977. [PMID: 31700569 PMCID: PMC6825739 DOI: 10.4317/jced.56002] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Accepted: 09/09/2019] [Indexed: 12/01/2022] Open
Abstract
Background Endocrown restorations as a conservative approach to restore endodontically treated teeth still need in vitro investigation under fatigue and made in different materials. This study evaluated the effect of restorative material and restoration thickness on the maximum fracture load of endocrowns subjected to cyclic loading. Material and Methods Sixty (60) third molar teeth received an endocrown preparation with three different heights of remaining dental tissue (1.5, 3.0 or 4.5 mm). A leucite-based ceramic (LEU) and a lithium disilicate (LD) based ceramic were selected to manufacture the CAD/CAM endocrown restorations, totaling 6 groups (n=10). The specimens were subjected to fatigue loading (200N, 2 x 106 cycles, water) and then to the single load to failure test (1 mm/min crosshead speed). Data were analyzed by using two-way ANOVA and Tukey tests (p< 0.05). Results All endocrowns survived the fatigue test. The thickness did not influence the restoration’s fracture load (p=0.548) instead the restorative material (p=0.003). LD showed higher mean values (1714.43 N)A than LEU (1313.47 N)B. Conclusions Endocrowns manufactured with CAD/CAM lithium disilicate blocks showed superior fracture load than the leucite-based blocks after mechanical fatigue. Nevertheless, both materials presented acceptable survival and fracture load as long as the material’s minimum thickness and the enamel adhesion are respected. Key words:Endocrown, CAD/CAM, Endodontically treated teeth, Failure load, Minimal intervention dentistry.
Collapse
Affiliation(s)
- João-Paulo-Mendes Tribst
- DDs, MSc, PhD Student in Prosthodontics, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil
| | - Amanda-Maria-de Oliveira Dal Piva
- DDs, MSc, PhD Student in Prosthodontics, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil
| | - Camila-Ferreira-Leite Madruga
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, n° 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil
| | - Marcia-Carneiro Valera
- Department of Restorative Dentistry, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, n° 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil
| | - Eduardo Bresciani
- Department of Restorative Dentistry, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, n° 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil
| | - Marco-Antonio Bottino
- DDs, MSc, PhD, Professor, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil
| | - Renata-Marques de Melo
- DDs, MSc, PhD, Researcher III, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil
| |
Collapse
|
64
|
Zhai XY, Zhang JY, Zhang SK, Jiang CJ, Qiu XX. [Finite-element analysis of mandibular first molar with two marginal designs of endocrown for the repair of different defects]. HUA XI KOU QIANG YI XUE ZA ZHI = HUAXI KOUQIANG YIXUE ZAZHI = WEST CHINA JOURNAL OF STOMATOLOGY 2019; 37:480-484. [PMID: 31721493 PMCID: PMC7030409 DOI: 10.7518/hxkq.2019.05.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 03/30/2019] [Revised: 06/21/2019] [Indexed: 11/21/2022]
Abstract
OBJECTIVE This study aimed to evaluate the stress distribution of the mandibular first molar with different thicknesses and heights of the axial wall restored by the endocrown with two marginal designs and thus provide a theoretical basis for selecting clinical preparation through the finite-element method. METHODS Two marginal endocrowns of the mandibular first molar with different axial-wall thicknesses (t=1, 2, 3 mm) and heights (h=2, 3, 4 mm) were established. Group A was the butt-joint design, whereas group B was the shoulder-surrounded design. After applying vertical and oblique loads , the size and distribution of the maximum principal stress and equivalent stress of residual tooth tissue were recorded. RESULTS The maximum principal stress and equivalent stress distribution of residual tooth tissue were similar among different models. Group A showed a lower maximum principal stress and equivalent stress than group B at the same thickness and height under vertical load. Meanwhile, under oblique load, the maximum principal stress values of groups A and B decreased with increased thickness at constant height. Group A showed lower equivalent stress than group B at the same thickness and height of 2 and
3 mm. However, when the height was 4 mm, the trend was reversed. CONCLUSIONS In mastication, when bearing the vertical force, the retention of the butt-joint marginal endocrown preferred to the shoulder-surrounded one. Given the higher axial wall of the shoulder-surrounded marginal endocrown, it showed better ability to bear the oblique force than the butt-joint one.
Collapse
Affiliation(s)
- Xiao-Yang Zhai
- Dept. of Prosthodontics, The First Affiliated Hospital of Zhengzhou University, Stomatological College of Zhengzhou University, Zhengzhou 450052, China
| | - Jing-Ya Zhang
- Dept. of Prosthodontics, The First Affiliated Hospital of Zhengzhou University, Stomatological College of Zhengzhou University, Zhengzhou 450052, China
| | - San-Ke Zhang
- Dept. of Prosthodontics, The First Affiliated Hospital of Zhengzhou University, Stomatological College of Zhengzhou University, Zhengzhou 450052, China
| | - Chuan-Jing Jiang
- Dept. of Prosthodontics, The First Affiliated Hospital of Zhengzhou University, Stomatological College of Zhengzhou University, Zhengzhou 450052, China
| | - Xiao-Xia Qiu
- Dept. of Prosthodontics, The First Affiliated Hospital of Zhengzhou University, Stomatological College of Zhengzhou University, Zhengzhou 450052, China
| |
Collapse
|
65
|
Seddik T, Derelioglu S. Effect of Endocrowns on Fracture Strength and Microleakage of Endodontically Treated Primary Molar Teeth. JOURNAL OF ADVANCED ORAL RESEARCH 2019. [DOI: 10.1177/2320206819861223] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Objectives: Optimal restoration of endodontically treated teeth is very important for the durability of the endodontic treatment. The focus of this study was to evaluate the fracture strength and microleakage of composite endocrowns compared with Class II composite restorations in endodontically treated primary molar teeth. Materials and Methods: 48 extracted second primary molars were divided into 2 groups. Group 1 (control): teeth with Class II and endodontic access cavities restored with G-aenial composite; group 2: endocrown restorations with G-aenial composite. After completing restorative procedures, teeth were subjected to thermal cycling (500 cycles). Compressive loading was applied to half of the samples, although the other half were immersed in 0.5% basic fucsin solution for 24 h, sectioned, and examined for dye penetration under stereomicroscope. Data were subjected to statistical analysis by the Mann-Whitney U test (α = 0.05). Results: The fracture strength of endocrowns (1741 ± 379.35 N) was significantly higher than that of the control group (1126.5 ± 405.39 N) ( P < .05). No statistical difference was found in microleakage between the 2 groups ( P > .05). Conclusion: Endocrown preparation increases the fracture strength of the final composite restoration when used in primary molar teeth. Composite endocrown restorations can be a practical and an esthetic option for restoring endodontically treated primary molar teeth.
Collapse
Affiliation(s)
- Tarek Seddik
- Department of Pedodontics, Faculty of Dentistry, Atatürk University, Erzurum, Turkey
| | - Sera Derelioglu
- Department of Pedodontics, Faculty of Dentistry, Atatürk University, Erzurum, Turkey
| |
Collapse
|
66
|
Evaluation of Fracture Resistance and Microleakage of Endocrowns with Different Intracoronal Depths and Restorative Materials Luted with Various Resin Cements. MATERIALS 2019; 12:ma12162528. [PMID: 31398883 PMCID: PMC6720342 DOI: 10.3390/ma12162528] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2019] [Revised: 07/28/2019] [Accepted: 08/06/2019] [Indexed: 11/18/2022]
Abstract
The aim of this study was to determine the effect of restoration design on the fracture resistance of different computer-aided design/computer-aided manufacturing (CAD/CAM) ceramics and investigate the marginal leakage of endocrowns according to different types of cement. In total, 96 extracted mandibular first premolars were used for fabrication of endocrowns; 48 of the endocrowns were divided into 6 groups (n = 8) according to intracoronal cavity depth (2 and 3 mm) and CAD/CAM ceramics (lithium disilicate IPS e.max-CAD, zirconia-reinforced glass-ceramic Vita Suprinity, and poly-ether-ether-ketone (PEEK)). Teeth were subjected to a fracture resistance test with a universal test machine following thermo-cycling. Failure modes were determined by stereomicroscope after the load test. The rest of the endocrowns (n = 48) were produced by Vita Suprinity ceramic and divided into 6 groups (n = 8) according to the cement used (Panavia V5, Relyx Ultimate, and GC cement) with intracoronal cavity depths of 2 and 3 mm. Microleakage tests were performed using methylene blue with stereomicroscope after thermo-cycling. Numerical data for both fracture resistance and microleakage tests were obtained and evaluated by three-way ANOVA. PEEK endocrowns had higher fracture resistance compared to lithium disilicate and Vita Suprinity. Panavia V5 cement had the lowest degree of microleakage, while GC cement had the highest. Different intracoronal cavity depths had no correlation with fracture resistance and microleakage.
Collapse
|
67
|
Sun J, Ruan W, He J, Lin X, Ci B, Yin S, Yan W. Clinical efficacy of different marginal forms of endocrowns: study protocol for a randomized controlled trial. Trials 2019; 20:454. [PMID: 31340845 PMCID: PMC6657076 DOI: 10.1186/s13063-019-3530-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2018] [Accepted: 06/17/2019] [Indexed: 11/23/2022] Open
Abstract
Background After root canal treatment, most tooth defects need to be restored. Onlay restoration is widely used to restore dental defects. Endocrown is a new type of onlay; however, dentists have yet to obtain a full understanding of the clinical effects of marginal forms of endocrowns. Here, we present a multicenter protocol to compare the clinical efficacy of two marginal forms (flat and 90-degree shoulder) for tooth restoration. The efficacy will be evaluated by marginal fit, marginal discoloration, and integrity of restoration. Methods The proposed flat and 90-degree shoulder marginal endocrown assessment trial is an open-label, parallel-group, multicenter randomized controlled trial involving two hospitals. A total of 200 patients will be included in this trial, and the following patient inclusion criteria will be applied: good oral hygiene habits, no periodontal diseases, receipt of standard root canal treatment, and need for endocrown restoration. Patients will be enrolled after providing signed informed consent and will be divided into two groups (flat and 90-degree shoulder endocrown) in accordance with a random number table. Treatment allocation will be balanced (1:1). Endocrowns will be cemented by dual-cured luting composite. Clinical evaluations will be performed at baseline and at 24 months after treatment in accordance with modified US Public Health Service criteria by two independent evaluators. The primary outcome will be marginal fit; secondary outcome measures will include debonding, marginal discoloration, and integrity of restoration. All acquired data will be analyzed by an independent statistician. Wilcoxon one-sample tests will be used for intra-group comparisons, and Wilcoxon two-sample tests will be used for inter-group comparisons. The Bonferroni method will be used to correct for multiple comparisons, and hierarchical logistic regression will be applied to determine central effects. Discussion The results of this trial will provide a clinical basis for clinicians to restore teeth by endocrowns and to improve long-term restoration for patients. Trial registration ClinicalTrials.gov identifier: NCT03398395. Registered on 12 January 2018. Electronic supplementary material The online version of this article (10.1186/s13063-019-3530-1) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Jieli Sun
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Rd, Guangzhou, 510515, China
| | - Wenhao Ruan
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Rd, Guangzhou, 510515, China
| | - Jiahui He
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Rd, Guangzhou, 510515, China
| | - Xiaoyu Lin
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Rd, Guangzhou, 510515, China
| | - Bowen Ci
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Rd, Guangzhou, 510515, China
| | - Siye Yin
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Rd, Guangzhou, 510515, China
| | - Wenjuan Yan
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Rd, Guangzhou, 510515, China.
| |
Collapse
|
68
|
El Ghoul W, Özcan M, Silwadi M, Salameh Z. Fracture resistance and failure modes of endocrowns manufactured with different CAD/CAM materials under axial and lateral loading. J ESTHET RESTOR DENT 2019; 31:378-387. [DOI: 10.1111/jerd.12486] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2018] [Revised: 01/28/2019] [Accepted: 04/09/2019] [Indexed: 01/10/2023]
Affiliation(s)
- Wiam El Ghoul
- Lebanese UniversityFaculty of Dental Medicine, Department of Prosthodontics Beirut Lebanon
| | - Mutlu Özcan
- University of ZurichCenter for Dental and Oral Medicine, Division of Dental Biomaterials Zurich Switzerland
| | - Munir Silwadi
- Lebanese UniversityFaculty of Dental Medicine, Department of Prosthodontics Beirut Lebanon
| | - Ziad Salameh
- Lebanese UniversityFaculty of Dental Medicine, Department of Prosthodontics Beirut Lebanon
| |
Collapse
|
69
|
El Ghoul WA, Özcan M, Ounsi H, Tohme H, Salameh Z. Effect of different CAD-CAM materials on the marginal and internal adaptation of endocrown restorations: An in vitro study. J Prosthet Dent 2019; 123:128-134. [PMID: 31027958 DOI: 10.1016/j.prosdent.2018.10.024] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2018] [Revised: 10/12/2018] [Accepted: 10/12/2018] [Indexed: 11/19/2022]
Abstract
STATEMENT OF PROBLEM Recent resin-based and ceramic-based computer-aided design and computer-aided manufacturing (CAD-CAM) materials have been used to restore endodontically treated teeth. Adaptation of the restoration is important for clinical success, but studies evaluating the effect of these materials on the adaptation of endocrowns are lacking. PURPOSE The purpose of this in vitro study was to evaluate the effect of resin-based and ceramic-based materials on the marginal and internal adaptation of endocrowns. MATERIAL AND METHODS Forty mandibular molars were divided into 4 groups (n=10); each group was restored with a different CAD-CAM material: group C: hybrid nanoceramic (Cerasmart; GC Corp), group T: fiber-composite material (Trilor; Bioloren Srl), group E: lithium disilicate glass-ceramic (IPS e.max CAD; Ivoclar Vivadent AG), and group V: zirconia-reinforced lithium silicate glass-ceramic (Vita Suprinity; VITA Zahnfabrik GmbH). A digital scan was made with an intraoral digital scanner (TRIOS 3; 3Shape A/S), and endocrowns were milled with a 5-axis milling machine (Coritec 250i; imes-icore GmbH). The replica technique and a stereomicroscope (×70) were used to measure the marginal and internal adaptation of the endocrowns at 32 points. All data were statistically analyzed using 1-way ANOVA and the Tukey honestly significant difference test (α=.05). RESULTS Statistical tests showed significant differences among the tested groups (P<.001). The resin-based groups displayed larger discrepancies than the ceramic-based groups. The resin-based groups showed a mean marginal gap larger than the mean internal gap C (P=.009), T (P<.001), whereas the ceramic-based groups showed similar gaps, V (P=.396), E (P=.936). The largest gap was observed at the pulpal floor (P<.001). CONCLUSIONS All materials had clinically acceptable internal and marginal gaps (≤150 μm), except for the marginal gap of the Trilor group.
Collapse
Affiliation(s)
- Wiam A El Ghoul
- Chief of clinical services, Department of Prosthodontics, School of Dentistry, Lebanese University, Beirut, Lebanon.
| | - Mutlu Özcan
- Professor, Department of Dental Materials, School of Dentistry, University of Zurich, Zurich, Switzerland
| | - Hani Ounsi
- Professor, Department of Endodontics, School of Dentistry, Lebanese University, Beirut, Lebanon
| | - Hani Tohme
- Department of Prosthodontics, School of Dentistry, Saint Joseph University, Beirut, Lebanon
| | - Ziad Salameh
- Professor, Department of Research, Department of Prosthodontics, School of Dentistry, Lebanese University, Beirut, Lebanon
| |
Collapse
|
70
|
Tzimas K, Tsiafitsa M, Gerasimou P, Tsitrou E. Endocrown restorations for extensively damaged posterior teeth: clinical performance of three cases. Restor Dent Endod 2018; 43:e38. [PMID: 30483462 PMCID: PMC6237728 DOI: 10.5395/rde.2018.43.e38] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2018] [Accepted: 07/09/2018] [Indexed: 11/11/2022] Open
Abstract
The restoration of endodontically treated teeth (ETT) with more than one cusp missing and thin remaining walls is challenging for the general practitioner. The use of posts combined with full coverage restorations is a well-established approach, yet not following the minimal invasive principles of adhesive dentistry. Endocrowns are indirect monoblock restorations that use the pulp chamber of the ETT for retention. In this study the fabrication of 4 endocrowns and their clinical performance will be discussed. Two clinical cases include computer-aided design/computer-aided manufacturing manufactured molar endocrowns (one feldspathic ceramic and one hybrid composite-ceramic restoration) and the other two are dental laboratory manufactured resin composite premolar endocrown restorations. The modified United States Public Health Service criteria were used to assess the clinical behavior of the restorations at different follow up periods. Endocrown restorations present a satisfactory clinical alternative, either by the use of resin composite or glass ceramic and hybrid materials. Specific guidelines with minimal alterations should be followed for an endocrown restoration to be successful. Due to limited evidence regarding the long term evaluation of this restorative technique, a careful selection of cases should be applied.
Collapse
Affiliation(s)
- Konstantinos Tzimas
- Department of Operative Dentistry, School of Dentistry, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Maria Tsiafitsa
- Department of Operative Dentistry, School of Dentistry, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Paris Gerasimou
- Department of Operative Dentistry, School of Dentistry, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Effrosyni Tsitrou
- Department of Operative Dentistry, School of Dentistry, Aristotle University of Thessaloniki, Thessaloniki, Greece
| |
Collapse
|
71
|
da Fonseca GF, de Andrade GS, Dal Piva AMDO, Tribst JPM, Borges ALS. Computer-aided design finite element modeling of different approaches to rehabilitate endodontically treated teeth. J Indian Prosthodont Soc 2018; 18:329-335. [PMID: 30449961 PMCID: PMC6180740 DOI: 10.4103/jips.jips_168_18] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Accepted: 08/01/2018] [Indexed: 11/18/2022] Open
Abstract
Background: Carious lesions and dental fractures cause weakening in the dental structure. In these situations, endodontic treatment and prosthetic rehabilitation using an intraradicular post are indicated. However, the postspace preparation of the root canal further weakens the dental remnant, especially if there is no ferrule present. This study aimed to evaluate the stress distribution in endodontically treated upper premolars treated with different rehabilitation approaches. Materials and Methods: An endodontically treated first upper premolar was modeled for finite element analysis. Three different approaches were carried out on this model: rehabilitation with fiberglass post (FCP), endocrown (ECW), or buildup. The models were exported in STEP format to the analysis software (ANSYS 17.2, ANSYS Inc., Houston, TX, USA). The solids were considered isotropic, homogeneous, and linearly elastic. A mechanical, structural static analysis was used as the criterion of maximum principal stress to show regions under tensile stress to evaluate the stress distribution in the restoration, cementation line, and root. A load of 400 N (90°) was applied to the lingual triangular ridge. The values of maximum principal stress in MPa were evaluated through colorimetric graphs. Results: Similar stress concentration was observed for all groups. However, the ECW group presented higher values in the restoration/cement interface and root dentin. Conclusions: All the treatment modalities had favorable mechanical behavior to support the masticatory loads; nevertheless, the ECW group presented a higher risk of detachment failure.
Collapse
Affiliation(s)
- Gabriela Fernandes da Fonseca
- Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos/SP, Brazil
| | - Guilherme Schmitt de Andrade
- Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos/SP, Brazil
| | - Amanda Maria de Oliveira Dal Piva
- Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos/SP, Brazil
| | - João Paulo Mendes Tribst
- Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos/SP, Brazil
| | - Alexandre Luiz Souto Borges
- Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos/SP, Brazil
| |
Collapse
|
72
|
Fracture load of CAD/CAM-fabricated and 3D-printed composite crowns as a function of material thickness. Clin Oral Investig 2018; 23:2777-2784. [DOI: 10.1007/s00784-018-2717-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Accepted: 10/17/2018] [Indexed: 10/28/2022]
|
73
|
Endocrown restorations: Influence of dental remnant and restorative material on stress distribution. Dent Mater 2018; 34:1466-1473. [DOI: 10.1016/j.dental.2018.06.012] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2017] [Revised: 05/08/2018] [Accepted: 06/07/2018] [Indexed: 11/17/2022]
|
74
|
Krance A, DuVall N, Brewster J, Roberts H. Fracture resistance of all-ceramic crowns based on different preparation designs for restoring endodontically treated molars. J ESTHET RESTOR DENT 2018; 31:72-79. [PMID: 30144367 DOI: 10.1111/jerd.12410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2018] [Revised: 04/27/2018] [Accepted: 06/11/2018] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To evaluate endodontically treated molar fracture resistance restored with CAD/CAM lithium disilicate (LDS) crowns with different amalgam core preparation design. MATERIALS AND METHODS Eighty-four recently extracted mandibular third molars were divided into seven groups (n = 12) and embedded in autopolymerizing resin. Coronal tooth structure was removed, pulp chamber exposed, and pulpal remnants removed. One group received LDS endocrowns, while three groups received amalgam cores with 2, 1, and 0 dentin axial wall heights (AWH). Three additional groups were likewise restored using an amalgam adhesive. Scanned preparations were restored with LDS crowns luted with a self-adhesive luting cement. After 24 hours, specimens were loaded to failure with results analyzed with Welch's Test/REGW Range Test at a 95% level of confidence (α = 0.05). RESULTS The 1 mm-AWH amalgam core group had the highest failure load and was similar to the 2 mm-AWH amalgam, 2 mm-AWH bonded amalgam, and the 1 mm-AWH bonded amalgam core groups. The endocrowns had lower failure load than the 1 mm and 2 mm AWH amalgam groups but was similar to other groups. CONCLUSIONS Adhesively luted LDS crowns with amalgam core preparations overall displayed similar failure load, as endocrown restorations. However, crowns based on amalgam cores demonstrated favorable failure modes. CLINICAL SIGNIFICANCE The results of this in vitro test suggests that when suitable tooth structure and sufficient interact restorative space exists, endodontically treated molars restored with lithium disilicate complete crowns based on preparations with amalgam core foundations containing 1 mm and 2 mm of dentin axial wall height could serve as a suitable restorative option that may provide more recoverable failure modes than endocrown restorations.
Collapse
Affiliation(s)
- Aaron Krance
- Dental Flight Commander, Dover Air Force Base, Delaware
| | | | - John Brewster
- Graduate Dental Research, USAF Postgraduate Dental School, Keesler, AFB, Mississippi
| | - Howard Roberts
- Division of Restorative Dentistry, University of Kentucky College of Dentistry, Lexington, Kentucky
| |
Collapse
|
75
|
Taha D, Spintzyk S, Sabet A, Wahsh M, Salah T. Assessment of marginal adaptation and fracture resistance of endocrown restorations utilizing different machinable blocks subjected to thermomechanical aging. J ESTHET RESTOR DENT 2018; 30:319-328. [PMID: 30113129 DOI: 10.1111/jerd.12396] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 04/22/2018] [Accepted: 05/13/2018] [Indexed: 11/30/2022]
Abstract
OBJECTIVE This in vitro study was conducted to assess the marginal adaptation and fracture resistance of computer aided design/computer aided manufacturer (CAD-CAM) fabricated endocrowns restoring endodontically treated molars using different machinable blocks with thermomechanical loading protocols. MATERIALS AND METHODS Devitalized mandibular molars were prepared in a standardized way and divided into 4 groups (n = 10) to receive CAD/CAM fabricated endocrowns using four materials (Lithium disilicate ceramics, polymer infiltrated ceramics, zirconia-reinforced lithium silicate ceramics and resin nanoceramics. Marginal gaps (µm) were measured using stereomicroscope before cementation and after cementation. After thermomechanical aging, marginal gap measurements were repeated, and then fracture resistance test was performed. Two-way analysis of variance (ANOVA) and Tukey HSD multiple comparisons were used to assess the effect of material on the marginal gap before, after cementation, and after thermomechanical aging. One Way ANOVA was used to assess the effect of material on the fracture resistance. RESULTS The difference between marginal gaps values of the tested materials was statistically insignificant but with significant increase after cementation and after thermomechanical aging. Cerasmart endocrowns showed the highest mean fracture load value (1508.5 ± 421.7N) with statistically significant difference than Vita Enamic endocrowns and Celtra Duo. CONCLUSION The tested materials showed marginal vertical gap readings within the limits of clinically acceptable standards. Resin nanoceramics and lithium disilicate showed the highest values of fracture resistance followed by polymer infiltrated ceramics favoring their use for endocrown restorations. CLINICAL SIGNIFICANCE The mechanical behavior of ceramic materials varies with the variation of their structure and mechanical properties. Accordingly, further investigation is always needed to explore the biomechanical behavior of recent materials when used as endocrowns before clinical trials.
Collapse
Affiliation(s)
- Doaa Taha
- Section Medical Materials science & technology, University Hospital Tübingen, Tübingen, Germany.,Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Sebastian Spintzyk
- Section Medical Materials Science & Technology, University Hospital Tübingen, Germany
| | - Ahmed Sabet
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Marwa Wahsh
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Tarek Salah
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| |
Collapse
|
76
|
Dartora NR, de Conto Ferreira MB, Moris ICM, Brazão EH, Spazin AO, Sousa-Neto MD, Silva-Sousa YT, Gomes EA. Effect of Intracoronal Depth of Teeth Restored with Endocrowns on Fracture Resistance: In Vitro and 3-dimensional Finite Element Analysis. J Endod 2018; 44:1179-1185. [DOI: 10.1016/j.joen.2018.04.008] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2017] [Revised: 03/28/2018] [Accepted: 04/08/2018] [Indexed: 11/16/2022]
|
77
|
Hayes A, Duvall N, Wajdowicz M, Roberts H. Effect of Endocrown Pulp Chamber Extension Depth on Molar Fracture Resistance. Oper Dent 2018; 42:327-334. [PMID: 28467258 DOI: 10.2341/16-097-l] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
PURPOSE The purpose of this study was to evaluate the effect of endocrown pulp chamber extension on mandibular molar fracture resistance. METHODS AND MATERIALS A total of 36 recently extracted mandibular third molars of approximate equal size were sectioned at the facial lingual height of contour followed by endodontic access into the pulp chamber. The specimens were then randomly divided into three groups (n=12) and pulpal and root canal contents removed. Pulp chamber floors were established at 2, 3, and 4 mm from the occlusal table using a three-step etch-and-rinse adhesive and a flowable resin composite. The prepared specimens were then embedded in auto-polymerizing denture base resin with surface area available for adhesive bonding determined using a digital recording microscope. Specimens were restored using a standardized template with a chairside computer-aided design/computer-aided manufacturing unit with the endocrown milled from a lithium disilicate glass-ceramic material. Restoration parameters of occlusal table anatomy and thickness were standardized with the only parameter difference being the pulp chamber extension depth. The endocrown restorations were luted with a self-adhesive resin luting agent and tested to failure after 24 hours on a universal testing machine, with force applied to the facial cusps at a 45° angle to the long axis of the tooth. The failure load was converted into stress for each specimen using the available surface area for bonding. Mean failure load and stress among the three groups was first subjected to the Shapiro-Wilk and Bartlett tests and then analyzed with an analysis of variance with the Tukey post hoc test at a 95% confidence level (p=0.05). RESULTS The 2- and 4-mm chamber extension groups demonstrated the highest fracture resistance stress, with the 3-mm group similar to the 2-mm group. The 3- and 4-mm chamber extension group specimens demonstrated nearly universal catastrophic tooth fracture, whereas half the 2-mm chamber extension group displayed nonrestorable root fractures. CONCLUSIONS Under the conditions of this study, mandibular molars restored with the endocrown technique with 2- and 4-mm pulp chamber extensions displayed greater tooth fracture resistance force as well as stress. All groups demonstrated a high number of catastrophic fractures, but these results may not be clinically significant because the fracture force results are higher than normal reported values of masticatory function.
Collapse
|
78
|
Kanat-Ertürk B, Saridağ S, Köseler E, Helvacioğlu-Yiğit D, Avcu E, Yildiran-Avcu Y. Fracture strengths of endocrown restorations fabricated with different preparation depths and CAD/CAM materials. Dent Mater J 2018; 37:256-265. [PMID: 29311428 DOI: 10.4012/dmj.2017-035] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The objectives of this study were to compare the fracture strength of endocrown restorations fabricated with different preparation depth and various CAD/CAM ceramics, and to assess the fracture types. Endodontically treated 100 extracted human permanent maxillary centrals were divided into two preparation depth groups as short (S: 3-mm-deep) and long (L: 6-mm-deep), then five ceramic subgroups, namely: feldspathic-ceramic (Vita Mark II-VM2), lithium-disilicate glass-ceramic (IPS e.max CAD-E.max), resin-ceramic (LAVA Ultimate-LU), polymer infiltrated ceramic (Vita Enamic-VE) and monoblock zirconia (inCoris TZI-TZI) (n=10/subgroup). The endocrowns were fabricated by CAD/CAM and were cemented with resin cement (RelyX U200). The teeth were thermally cycled (5,000cycles) and fracture tests were performed at 45º angle to the teeth. The data were statistically analyzed (Kruskal-Wallis, Mann Whitney U), failure modes were evaluated with stereomicroscopy. Zirconia group provided the statistically highest fracture strength, but also exhibited non-repairable failures. Preparation depth has an effect on the fracture strength only for feldspathic ceramic.
Collapse
Affiliation(s)
| | - Serkan Saridağ
- Department of Prosthodontics, Kocaeli University, Faculty of Dentistry
| | - Ege Köseler
- Department of Prosthodontics, Kocaeli University, Faculty of Dentistry
| | | | - Egemen Avcu
- Department of Machine and Metal Technologies, Kocaeli University, Ford Otosan İhsaniye Automotive Vocational School
| | | |
Collapse
|
79
|
Skalskyi V, Makeev V, Stankevych O, Pavlychko R. Features of fracture of prosthetic tooth-endocrown constructions by means of acoustic emission analysis. Dent Mater 2018; 34:e46-e55. [DOI: 10.1016/j.dental.2018.01.023] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2017] [Revised: 12/07/2017] [Accepted: 01/16/2018] [Indexed: 11/30/2022]
|
80
|
Subaşı MG, Alp G. Repair bond strengths of non-aged and aged resin nanoceramics. J Adv Prosthodont 2017; 9:364-370. [PMID: 29142644 PMCID: PMC5673613 DOI: 10.4047/jap.2017.9.5.364] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2016] [Revised: 06/07/2017] [Accepted: 07/04/2017] [Indexed: 11/23/2022] Open
Abstract
PURPOSE To explore the influence of different surface conditionings on surface changes and the influence of surface treatments and aging on the bond strengths of composites to non-aged and aged resin nanoceramics. MATERIALS AND METHODS Rectangular-shaped non-aged and aged (5000 thermocycles) resin nanoceramic specimens (Lava Ultimate) (n=63, each) were divided into 3 groups according to surface treatments (untreated, air abrasion, or silica coating) (n=21). The surface roughness was measured and scanning electron microscopy was used to examine one specimen from each group. Afterwards, the specimens were repaired with a composite resin (Filtek Z550) and half were sent for aging (5000 thermocycles, n=10, each). Shear bond strengths and failure types were evaluated. Roughness and bond strength were investigated by two- and three-way analysis of variance, respectively. The correlation between the roughness and bond strength was investigated by Pearson's correlation test. RESULTS Surface-treated samples had higher roughness compared with the untreated specimens (P=.000). For the non-aged resin nanoceramic groups, aging was a significant factor for bond strength; for the aged resin nanoceramic groups, surface treatment and aging were significant factors. The failures were mostly adhesive after thermal cycling, except in the non-aged untreated group and the aged air-abraded group, which had mostly mixed failures. Roughness and bond strength were positively correlated (P=.003). CONCLUSION Surface treatment is not required for the repair of non-aged resin nanoceramic; for the repair of aged resin nanoceramic restorations, air abrasion is recommended.
Collapse
Affiliation(s)
- Meryem Gülce Subaşı
- Department of Prosthodontics, Faculty of Dentistry, Istanbul Aydın University, Istanbul, Turkey
| | - Gülce Alp
- Department of Prosthodontics, Faculty of Dentistry, Okan University, Istanbul, Turkey
| |
Collapse
|
81
|
Einhorn M, DuVall N, Wajdowicz M, Brewster J, Roberts H. Preparation Ferrule Design Effect on Endocrown Failure Resistance. J Prosthodont 2017; 28:e237-e242. [DOI: 10.1111/jopr.12671] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/18/2017] [Indexed: 11/30/2022] Open
Affiliation(s)
| | | | - Michael Wajdowicz
- Graduate Dental Research; USAF Postgraduate School Keesler Air Force Base; MS
| | - John Brewster
- Graduate Dental Research; USAF Postgraduate School Keesler Air Force Base; MS
| | - Howard Roberts
- Graduate Dental Research; USAF Postgraduate School Keesler Air Force Base; MS
| |
Collapse
|
82
|
Dejak B, Młotkowski A. Strength comparison of anterior teeth restored with ceramic endocrowns vs custom-made post and cores. J Prosthodont Res 2017; 62:171-176. [PMID: 28886951 DOI: 10.1016/j.jpor.2017.08.005] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Revised: 07/28/2017] [Accepted: 08/16/2017] [Indexed: 10/18/2022]
Abstract
PURPOSE The aim of the study was to compare strength of the anterior teeth restored with ceramic endocrowns versus custom-made post and core. METHODS The investigation used the finite element analysis. Three 3-D models of maxillary central incisor were created: model A-tooth restored with metal post and core with ceramic crown; model B-tooth with leucite ceramic endocrown; model C-tooth with lithium disilicate ceramic endocrown. Each model was subjected to a 100N force applied at a distance of 5mm from the incisal edge, at the angle of 130° to the long axis of the tooth. The modified von Mises failure criterion was used to evaluate the strength of the dentin, ceramic and resin cement, and Huber-Mises-Hencky failure criterion for cast alloy. Contact stresses in the cement-tissue adhesive interface were calculated. RESULTS The lowest stresses occurred in the anterior tooth restored with custom post and core (model A). The mvM stress of 47.5MPa concentrated in leucite ceramic endocrown (model B) and its value was close to the tensile strength of this material. The maximal mvM stresses in the lithium disilicate ceramic endocrown (model C) were 4 times lower than tensile strength of this material. In all cases contact stresses in the adhesive interface under restorations did not exceed the resin cement bond strength to dentin. CONCLUSIONS Leucite ceramic endocrowns in incisors may fracture during physiological loading. Endocrowns made of lithium disilicate ceramic are resistant to failure. Posts and prosthetic crowns are still recommended for anterior teeth restorations.
Collapse
Affiliation(s)
- Beata Dejak
- Department of Prosthetic Dentistry, Medical University of Lodz, Lodz, Poland.
| | - Andrzej Młotkowski
- Department of Strength of Materials and Structures, Technical University of Lodz, Lodz, Poland
| |
Collapse
|
83
|
El-Damanhoury HM, Gaintantzopoulou MD. Self-etching ceramic primer versus hydrofluoric acid etching: Etching efficacy and bonding performance. J Prosthodont Res 2017; 62:75-83. [PMID: 28651905 DOI: 10.1016/j.jpor.2017.06.002] [Citation(s) in RCA: 84] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2016] [Revised: 05/31/2017] [Accepted: 06/05/2017] [Indexed: 11/28/2022]
Abstract
AIM This study assessed the effect of pretreatment of hybrid and glass ceramics using a self-etching primer on the shear bond strength (SBS) and surface topography, in comparison to pretreatment with hydrofluoric acid and silane. METHODS 40 rectangular discs from each ceramic material (IPS e.max CAD;EM, Vita Mark II;VM, Vita Enamic;VE), were equally divided (n=10) and assigned to one of four surface pretreatment methods; etching with 4.8% hydrofluoric acid followed by Monobond plus (HFMP), Monobond etch & prime (Ivoclar Vivadent) (MEP), No treatment (NT) as negative control and Monobond plus (Ivoclar Vivadent) with no etching (MP) as positive control. SBS of resin cement (Multilink-N, Ivoclar Vivadent) to ceramic surfaces was tested following a standard protocol. Surface roughness was evaluated using an Atomic force microscope (AFM). Surface topography and elemental analysis were analyzed using SEM/EDX. Data were analyzed with two-way analysis of variance (ANOVA) and post-hoc Bonferroni test at a significance level of α=0.05. RESULTS Pretreatment with HFMP resulted in higher SBS and increased surface roughness in comparison to MEP and MP. Regardless the method of surface pretreatment, the mean SBS values of EM ceramic was significantly higher (p<0.05) than those recorded for VM and VE, except when VE was treated with MEP, where the difference was statistically insignificant. Traces of fluoride ion were detected when MEP was used with VE and VM. CONCLUSION Under limited conditions, using MEP resulted in comparable SBS results to HFMP; meanwhile HFMP remains the gold standard for pretreatment of glass ceramics for resin-luting cementation.
Collapse
Affiliation(s)
- Hatem M El-Damanhoury
- Department of Preventive and Restorative Dentistry, College of Dental Medicine, University of Sharjah, Sharjah, United Arab Emirates; Department of Operative Dentistry, Faculty of Dentistry, Suez Canal University, Ismailia, Egypt.
| | - Maria D Gaintantzopoulou
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Greece
| |
Collapse
|
84
|
Biomechanical behavior of endodontically treated premolars using different preparation designs and CAD/CAM materials. J Dent 2017; 59:54-61. [PMID: 28214537 DOI: 10.1016/j.jdent.2017.02.007] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2016] [Revised: 02/07/2017] [Accepted: 02/13/2017] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVES To evaluate the effect of restoration design ('2.5-mm deep endocrown', '5-mm deep endocrown' or '5-mm deep post&crown') and CAD/CAM material type (composite or lithium disilicate glass-ceramic) on the load-to-failure of endodontically treated premolars in absence of any ferrule. METHODS The crowns of 48 single-rooted premolars were cut and the roots were endodontically treated. Teeth were randomly divided into six groups (n=8); teeth in each group were restored using one of the two tested materials with standardized CAD/CAM fabricated endocrowns (with either 2.5-mm or 5-mm deep intra-radicular extension) or conventional crowns (5-mm deep post&crown). After cementation using luting composite, the specimens were immersed in distilled water and subjected to 1,200,000 chewing cycles with a load of 50N applied parallel to the long axis of the tooth (0°). After cyclic loading, a compressive load was applied at 45° to the tooth's long axis using a universal testing machine until failure. Load-to-failure was recorded (N) and the specimens were examined under a stereomicroscope with 3.5x magnification to determine the mode of failure. RESULTS All specimens survived the 1,200,000 chewing cycles. A significant interaction between restoration design and CAD/CAM material was found using two-way ANOVA. In the '2.5-mm deep endocrown' groups, the composite achieved a significantly higher load-to-failure than the lithium disilicate glass-ceramic, while no differences between materials were found in the '5-mm deep endocrown' and '5-mm deep post&crown' groups. More unfavorable failures (root fractures) were observed for higher load-to-failure values. CONCLUSIONS Only following a '2.5-mm deep endocrown' design, composite appeared more favorable than lithium disilicate glass-ceramic as crown material; this may be explained by their difference in elastic modulus. CLINICAL SIGNIFICANCE Shallow endocrown preparations on premolars present less surface for adhesive luting and a difference in crown material becomes apparent in terms of load-to-failure. The use of a more flexible composite crown material appeared then a better option.
Collapse
|
85
|
Zoidis P, Bakiri E, Polyzois G. Using modified polyetheretherketone (PEEK) as an alternative material for endocrown restorations: A short-term clinical report. J Prosthet Dent 2017; 117:335-339. [DOI: 10.1016/j.prosdent.2016.08.009] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2016] [Revised: 08/08/2016] [Accepted: 08/12/2016] [Indexed: 11/30/2022]
|
86
|
BANKOĞLU GÜNGÖR M, TURHAN BAL B, YILMAZ H, AYDIN C, KARAKOCA NEMLİ S. Fracture strength of CAD/CAM fabricated lithium disilicate and resin nano ceramic restorations used for endodontically treated teeth. Dent Mater J 2017; 36:135-141. [DOI: 10.4012/dmj.2016-017] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
| | - Bilge TURHAN BAL
- Department of Prosthodontics, Faculty of Dentistry, Gazi University
| | - Handan YILMAZ
- Department of Prosthodontics, Faculty of Dentistry, Gazi University
| | - Cemal AYDIN
- Department of Prosthodontics, Faculty of Dentistry, Gazi University
| | | |
Collapse
|
87
|
Sagsoz O, Demirci T, Demirci G, Sagsoz NP, Yildiz M. The effects of different polishing techniques on the staining resistance of CAD/CAM resin-ceramics. J Adv Prosthodont 2016; 8:417-422. [PMID: 28018558 PMCID: PMC5179479 DOI: 10.4047/jap.2016.8.6.417] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2016] [Revised: 07/26/2016] [Accepted: 10/14/2016] [Indexed: 11/17/2022] Open
Abstract
PURPOSE The purposes of this study were to evaluate the staining resistance of CAD/CAM resin-ceramics polished with different techniques and to determine the effectiveness of the polishing techniques on resin-ceramics, comparing it with that of a glazed glass-ceramic. MATERIALS AND METHODS Four different CAD/CAM ceramics (feldspathic ceramic: C-CEREC Blocs, (SIRONA) and three resin-ceramics: L-Lava Ultimate, (3M ESPE), E-Enamic, (VITA) and CS-CeraSmart, (GC)) and one light cure composite resin: ME-Clearfil Majesty Esthetic (Kuraray) were used. Only C samples were glazed (gl). Other restorations were divided into four groups according to the polishing technique: nonpolished control group (c), a group polished with light cure liquid polish (Biscover LV BISCO) (bb), a group polished with ceramic polishing kit (Diapol, EVE) (cd), and a group polished with composite polishing kit (Clearfil Twist Dia, Kuraray) (kc). Glazed C samples and the polished samples were further divided into four subgroups and immersed into different solutions: distilled water, tea, coffee, and fermented black carrot juice. Eight samples (8 × 8 × 1 mm) were prepared for each subgroup. According to CIELab system, four color measurements were made: before immersion, immersion after 1 day, after 1 week, and after 1 month. Data were analyzed with repeated measures of ANOVA (α=.05). RESULTS The highest staining resistance was found in gl samples. There was no difference among gl, kc and cd (P>.05). Staining resistance of gl was significantly higher than that of bb (P<.05). Staining resistances of E and CS were significantly higher than those of L and ME (P<.05). CONCLUSION Ceramic and composite polishing kits can be used for resin ceramics as a counterpart of glazing procedure used for full ceramic materials. Liquid polish has limited indications for resin ceramics.
Collapse
Affiliation(s)
- Omer Sagsoz
- Department of Restorative Treatment, Faculty of Dentistry, Ataturk University, Erzurum, Turkey
| | - Tevfik Demirci
- Department of Pediatric Dentistry, Faculty of Dentistry, Ataturk University, Erzurum, Turkey
| | - Gamze Demirci
- Department of Restorative Treatment, Faculty of Dentistry, Ataturk University, Erzurum, Turkey
| | - Nurdan Polat Sagsoz
- Department of Dental Prosthetic Technologies, Health Services Vocational School, Ataturk University, Erzurum, Turkey
| | - Mehmet Yildiz
- Department of Restorative Treatment, Faculty of Dentistry, Ataturk University, Erzurum, Turkey
| |
Collapse
|
88
|
Gaintantzopoulou MD, El-Damanhoury HM. Effect of Preparation Depth on the Marginal and Internal Adaptation of Computer-aided Design/Computer-assisted Manufacture Endocrowns. Oper Dent 2016; 41:607-616. [DOI: 10.2341/15-146-l] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
The aim of the study was to evaluate the effect of preparation depth and intraradicular extension on the marginal and internal adaptation of computer-aided design/computer-assisted manufacture (CAD/CAM) endocrown restorations. Standardized preparations were made in resin endodontic tooth models (Nissin Dental), with an intracoronal preparation depth of 2 mm (group H2), with extra 1- (group H3) or 2-mm (group H4) intraradicular extensions in the root canals (n=12). Vita Enamic polymer-infiltrated ceramic-network material endocrowns were fabricated using the CEREC AC CAD/CAM system and were seated on the prepared teeth. Specimens were evaluated by microtomography. Horizontal and vertical tomographic sections were recorded and reconstructed by using the CTSkan software (TView v1.1, Skyscan).The surface/void volume (S/V) in the region of interest was calculated. Marginal gap (MG), absolute marginal discrepancy (MD), and internal marginal gap were measured at various measuring locations and calculated in microscale (μm). Marginal and internal discrepancy data (μm) were analyzed with nonparametric Kruskal-Wallis analysis of variance by ranks with Dunn's post hoc, whereas S/V data were analyzed by one-way analysis of variance and Bonferroni multiple comparisons (α=0.05). Significant differences were found in MG, MD, and internal gap width values between the groups, with H2 showing the lowest values from all groups. S/V calculations presented significant differences between H2 and the other two groups (H3 and H4) tested, with H2 again showing the lowest values. Increasing the intraradicular extension of endocrown restorations increased the marginal and internal gap of endocrown restorations.
Collapse
Affiliation(s)
- MD Gaintantzopoulou
- Marianna D Gaintantzopoulou, DDS, MSD, PhD, assistant professor, Department of Preventive and Restorative Dentistry, College of Dental Medicine, University of Sharjah, Sharjah, United Arab Emirates
| | - HM El-Damanhoury
- Hatem M El-Damanhoury, BDS, MDS, PhD, assistant professor, Department of Preventive and Restorative Dentistry, College of Dental Medicine, University of Sharjah, Sharjah, United Arab Emirates; and Department of Operative Dentistry, Faculty of Dentistry, Suez Canal University, Ismailia, Egypt
| |
Collapse
|
89
|
Influence of remaining tooth structure and restorative material type on stress distribution in endodontically treated maxillary premolars: A finite element analysis. J Prosthet Dent 2016; 117:646-655. [PMID: 27881319 DOI: 10.1016/j.prosdent.2016.08.023] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2016] [Revised: 08/06/2016] [Accepted: 08/08/2016] [Indexed: 10/20/2022]
Abstract
STATEMENT OF PROBLEM How tooth preparation and material type affect the stress distribution of endodontically treated teeth restored with endocrowns remains unclear. PURPOSE The purpose of this finite element (FE) study was to determine the influence of the quantity of remaining dental tissues and material type on stress distribution in endodontically treated maxillary premolars using 3-dimensional FE analysis. MATERIAL AND METHODS Five 3-dimensional FE models were constructed on the basis of the restorative methods used and the quantity of preserved tooth tissues: a sound maxillary premolar, an endodontically treated maxillary premolar restored with composite resin, and endodontically treated maxillary premolars restored with endocrowns with thicknesses of 1.0 mm, 2.0 mm, and 3.0 mm. The following endocrown materials were used: Paradigm MZ100, IPS Empress, IPS e.max CAD, and In-Ceram Zirconia. Stress distributions were analyzed under vertical and oblique loads. RESULTS As the quantity of preserved dental tissues increased, the von Mises stress in dentin decreased, and the peak von Mises strain value of the cement layer increased. When the elastic modulus of the endocrown material increased, the von Mises stress in endocrown and dentin increased, and the peak von Mises strain value of the cement layer decreased. CONCLUSIONS Although the conservative preparation of teeth for endocrowns is likely to protect the residual tooth structure, it may cause future cohesive bonding failure. An increase in the elastic modulus of the material may benefit the durability of bonding between the endocrown and the abutment tooth; however, it may cause fracture of the residual tooth structure.
Collapse
|
90
|
Endocrown restorations: A systematic review and meta-analysis. J Dent 2016; 52:8-14. [DOI: 10.1016/j.jdent.2016.07.005] [Citation(s) in RCA: 80] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2016] [Revised: 07/07/2016] [Accepted: 07/11/2016] [Indexed: 11/21/2022] Open
|
91
|
Edge chipping resistance and flexural strength of polymer infiltrated ceramic network and resin nanoceramic restorative materials. J Prosthet Dent 2016; 116:397-403. [PMID: 27157600 DOI: 10.1016/j.prosdent.2016.02.014] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2015] [Revised: 02/19/2016] [Accepted: 02/22/2016] [Indexed: 11/23/2022]
Abstract
STATEMENT OF PROBLEM Two novel restorative materials, a polymer infiltrated ceramic network (PICN) and a resin nanoceramic (RNC), for computer-assisted design and computer-assisted manufacturing (CAD-CAM) applications have recently become commercially available. Little independent evidence regarding their mechanical properties exists to facilitate material selection. PURPOSE The purpose of this in vitro study was to measure the edge chipping resistance and flexural strength of the PICN and RNC materials and compare them with 2 commonly used feldspathic ceramic (FC) and leucite reinforced glass-ceramic (LRGC) CAD-CAM materials that share the same clinical indications. MATERIAL AND METHODS PICN, RNC, FC, and LRGC material specimens were obtained by sectioning commercially available CAD-CAM blocks. Edge chipping test specimens (n=20/material) were adhesively attached to a resin substrate before testing. Edge chips were produced using a 120-degree, sharp, conical diamond indenter mounted on a universal testing machine and positioned 0.1 to 0.7 mm horizontally from the specimen's edge. The chipping force was plotted against distance to the edge, and the data were fitted to linear and quadratic equations. One-way ANOVA determined intergroup differences (α=.05) in edge chipping toughness. Beam specimens (n=22/material) were tested for determining flexural strength using a 3-point bend test. Weibull statistics determined intergroup differences (α=.05). Flexural modulus and work of fracture were also calculated, and 1-way ANOVA determined intergroup differences (α=.05) RESULTS: Significant (P<.05) differences were found among the 4 CAD-CAM materials for the 4 mechanical properties. Specifically, the material rankings were edge chipping toughness: RNC>LRGC=FC>PICN; flexural strength: RNC=LRGC>PICN>FC; flexural modulus: RNC<PICN<LRGC<FC; and work of fracture: RNC>LRGC=PICN>FC. CONCLUSIONS The RNC material demonstrated superior performance for the mechanical properties tested compared with the other 3 materials.
Collapse
|
92
|
Acar O, Yilmaz B, Altintas SH, Chandrasekaran I, Johnston WM. Color stainability of CAD/CAM and nanocomposite resin materials. J Prosthet Dent 2016; 115:71-5. [DOI: 10.1016/j.prosdent.2015.06.014] [Citation(s) in RCA: 119] [Impact Index Per Article: 14.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2015] [Revised: 06/21/2015] [Accepted: 06/26/2015] [Indexed: 10/23/2022]
|
93
|
Lawson NC, Burgess JO. Gloss and Stain Resistance of Ceramic-Polymer CAD/CAM Restorative Blocks. J ESTHET RESTOR DENT 2015; 28 Suppl 1:S40-5. [DOI: 10.1111/jerd.12166] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Nathaniel C. Lawson
- Department of Biomaterials; School of Dentistry, Clinical and Community Sciences; University of Alabama at Birmingham; 1919 7th Avenue South Birmingham AL 35205 USA
| | - John O. Burgess
- Department of Biomaterials; School of Dentistry, Clinical and Community Sciences; University of Alabama at Birmingham; 1919 7th Avenue South Birmingham AL 35205 USA
| |
Collapse
|
94
|
Sevimli G, Cengiz S, Oruc MS. Endocrowns: review. J Istanb Univ Fac Dent 2015; 49:57-63. [PMID: 28955538 PMCID: PMC5573486 DOI: 10.17096/jiufd.71363] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2013] [Accepted: 12/02/2014] [Indexed: 11/22/2022] Open
Abstract
The ideal restoration of endodontically treated
teeth (ETT) has been widely and controversially
discussed in the literature. Prevention of healthy
dental structure is essential to help mechanical
stabilization of tooth-restoration integrity, increase
the amount of suitable surfaces for adhesion and
thus positively affect the long-term success. ETT are
affected by a higher risk of biomechanical failure than
vital teeth. With the development of adhesive systems,
the need for post-core restorations is also reduced.
Especially for restoration of excessively damaged
ETT, endocrowns have been used as an alternative to
the conventional post-core and fixed partial dentures.
Compared to conventional methods, good aesthetics,
better mechanical performance, and less cost and
clinic time are the advantages of endocrowns.
Collapse
Affiliation(s)
- Gaye Sevimli
- Department of Prosthodontics, Faculty of Dentistry, Bulent Ecevit University, Turkey
| | - Seda Cengiz
- Department of Prosthodontics, Faculty of Dentistry, Bulent Ecevit University, Turkey
| | - M Selcuk Oruc
- Department of Prosthodontics, Faculty of Dentistry, Bulent Ecevit University, Turkey
| |
Collapse
|