51
|
Badhe RV, Akinfosile O, Bijukumar D, Barba M, Mathew MT. Systemic toxicity eliciting metal ion levels from metallic implants and orthopedic devices - A mini review. Toxicol Lett 2021; 350:213-224. [PMID: 34252509 DOI: 10.1016/j.toxlet.2021.07.004] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 06/19/2021] [Accepted: 07/07/2021] [Indexed: 12/28/2022]
Abstract
The metal/metal alloy-based implants and prostheses are in use for over a century, and the rejections, revisions, and metal particle-based toxicities were reported concurrently. Complications developed due to metal ions, metal debris, and organo-metallic particles in orthopedic patients have been a growing concern in recent years. It was reported that local and systemic toxicity caused by such released products from the implants is one of the major reasons for implant rejection and revision. Even though the description of environmental metal toxicants and safety limits for their exposure to humans were well established in the literature, an effort was not adequately performed in the case of implant-based metal toxicology. Since the metal ion concentration in serum acts as a possible indicator of the systemic toxicity, this review summarizes the reported human serum safe limits, toxic limits, and concentration range (μg/L, ppb, etc.) for mild to severe symptoms of six (cardiac, hepatic, neuro, nephron, dermal and endocrine) systemic toxicities for twelve most commonly used metallic implants. It also covers the widely used metal ion quantification techniques and systemic toxicity treatments reported.
Collapse
Affiliation(s)
- Ravindra V Badhe
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | - Obakanyin Akinfosile
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | - Divya Bijukumar
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | | | - Mathew T Mathew
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA.
| |
Collapse
|
52
|
Jiao J, Zhang S, Qu X, Yue B. Recent Advances in Research on Antibacterial Metals and Alloys as Implant Materials. Front Cell Infect Microbiol 2021; 11:693939. [PMID: 34277473 PMCID: PMC8283567 DOI: 10.3389/fcimb.2021.693939] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Accepted: 06/21/2021] [Indexed: 11/13/2022] Open
Abstract
Implants are widely used in orthopedic surgery and are gaining attention of late. However, their use is restricted by implant-associated infections (IAI), which represent one of the most serious and dangerous complications of implant surgeries. Various strategies have been developed to prevent and treat IAI, among which the closest to clinical translation is designing metal materials with antibacterial functions by alloying methods based on existing materials, including titanium, cobalt, tantalum, and biodegradable metals. This review first discusses the complex interaction between bacteria, host cells, and materials in IAI and the mechanisms underlying the antibacterial effects of biomedical metals and alloys. Then, their applications for the prevention and treatment of IAI are highlighted. Finally, new insights into their clinical translation are provided. This review also provides suggestions for further development of antibacterial metals and alloys.
Collapse
Affiliation(s)
- Juyang Jiao
- Department of Bone and Joint Surgery, Department of Orthopaedics, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Shutao Zhang
- Department of Bone and Joint Surgery, Department of Orthopaedics, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Xinhua Qu
- Department of Bone and Joint Surgery, Department of Orthopaedics, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Bing Yue
- Department of Bone and Joint Surgery, Department of Orthopaedics, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
53
|
Perino G, De Martino I, Zhang L, Xia Z, Gallo J, Natu S, Langton D, Huber M, Rakow A, Schoon J, Gomez-Barrena E, Krenn V. The contribution of the histopathological examination to the diagnosis of adverse local tissue reactions in arthroplasty. EFORT Open Rev 2021; 6:399-419. [PMID: 34267931 PMCID: PMC8246109 DOI: 10.1302/2058-5241.6.210013] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
The histopathological examination of the periprosthetic soft tissue and bone has contributed to the identification and description of the morphological features of adverse local tissue reactions (ALTR)/adverse reactions to metallic debris (ARMD). The need of a uniform vocabulary for all disciplines involved in the diagnosis and management of ALTR/ARMD and of clarification of the parameters used in the semi-quantitative scoring systems for their classification has been considered a pre-requisite for a meaningful interdisciplinary evaluation. This review of key terms used for ALTR/ARMD has resulted in the following outcomes: (a) pseudotumor is a descriptive term for ALTR/ARMD, classifiable in two main types according to its cellular composition defining its clinical course; (b) the substitution of the term metallosis with presence of metallic wear debris, since it cannot be used as a category of implant failure or histological diagnosis; (c) the term aseptic lymphocytic-dominated vasculitis- associated lesion (ALVAL) should be replaced due to the absence of a vasculitis with ALLTR/ALRMD for lymphocytic-predominant and AMLTR/AMRMD for macrophage-predominant reaction. This review of the histopathological classifications of ALTR/ARMD has resulted in the following outcomes: (a) distinction between cell death and tissue necrosis; (b) the association of corrosion metallic debris with adverse local lymphocytic reaction and tissue necrosis; (c) the importance of cell and particle debris for the viscosity and density of the lubricating synovial fluid; (d) a consensus classification of lymphocytic infiltrate in soft tissue and bone marrow; (e) evaluation of the macrophage infiltrate in soft tissues and bone marrow; (f) classification of macrophage induced osteolysis/aseptic loosening as a delayed type of ALTR/ARMD; (g) macrophage motility and migration as possible driving factor for osteolysis; (h) usefulness of the histopathological examination for the natural history of the adverse reactions, radiological correlation, post-marketing surveillance, and implant registries. The review of key terms used for the description and histopathological classification of ALTR/ARMD has resulted in a comprehensive, new standard for all disciplines involved in their diagnosis, clinical management, and long-term clinical follow-up.
Cite this article: EFORT Open Rev 2021;6:399-419. DOI: 10.1302/2058-5241.6.210013
Collapse
Affiliation(s)
- Giorgio Perino
- Department of Orthopedics and Orthopedic Surgery, University Medicine Greifswald, Greifswald, Germany
| | - Ivan De Martino
- Division of Orthopaedics and Traumatology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
| | - Lingxin Zhang
- Department of Pathology and Laboratory Medicine, Sinai Health System, Toronto, Canada
| | - Zhidao Xia
- Centre for Nanohealth, Swansea University Medical School, Singleton Park, Swansea, UK
| | - Jiri Gallo
- Department of Orthopaedics, Faculty of Medicine and Dentistry, University Hospital, Palacky University Olomouc, Czech Republic
| | - Shonali Natu
- Department of Pathology, University Hospital of North Tees and Hartlepool NHS Foundation Trust, Stockton-on-Tees, UK
| | - David Langton
- Orthopaedic Department, Freeman Hospital, Newcastle upon Tyne, UK
| | - Monika Huber
- Pathologisch-bakteriologisches Institut, Otto Wagner Spital, Wien, Austria
| | - Anastasia Rakow
- Department of Orthopedics and Orthopedic Surgery, University Medicine Greifswald, Greifswald, Germany
| | - Janosch Schoon
- Department of Orthopedics and Orthopedic Surgery, University Medicine Greifswald, Greifswald, Germany
| | - Enrique Gomez-Barrena
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario La Paz-IdiPAZ, Universidad Autónoma de Madrid, Madrid, Spain
| | - Veit Krenn
- MVZ-Zentrum für Histologie, Zytologie und Molekulare Diagnostik-GmbH, Trier, Germany
| |
Collapse
|
54
|
Jenkinson MRJ, Meek RMD, Tate R, MacMillan S, Grant MH, Currie S. Cobalt-induced cardiomyopathy - do circulating cobalt levels matter? Bone Joint Res 2021; 10:340-347. [PMID: 34053230 PMCID: PMC8242681 DOI: 10.1302/2046-3758.106.bjr-2020-0414.r2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Elevated levels of circulating cobalt ions have been linked with a wide range of systemic complications including neurological, endocrine, and cardiovascular symptoms. Case reports of patients with elevated blood cobalt ions have described significant cardiovascular complications including cardiomyopathy. However, correlation between the actual level of circulating cobalt and extent of cardiovascular injury has not previously been performed. This review examines evidence from the literature for a link between elevated blood cobalt levels secondary to metal-on-metal (MoM) hip arthroplasties and cardiomyopathy. Correlation between low, moderate, and high blood cobalt with cardiovascular complications has been considered. Elevated blood cobalt at levels over 250 µg/l have been shown to be a risk factor for developing systemic complications and published case reports document cardiomyopathy, cardiac transplantation, and death in patients with severely elevated blood cobalt ions. However, it is not clear that there is a hard cut-off value and cardiac dysfunction may occur at lower levels. Clinical and laboratory research has found conflicting evidence of cobalt-induced cardiomyopathy in patients with MoM hips. Further work needs to be done to clarify the link between severely elevated blood cobalt ions and cardiomyopathy. Cite this article: Bone Joint Res 2021;10(6):340–347.
Collapse
Affiliation(s)
| | | | - Rothwell Tate
- Strathclyde Institute of Pharmacy and Biomedical Sciences, University of Strathclyde, Glasgow, UK
| | | | - M Helen Grant
- Biomedical Engineering, University of Strathclyde, Glasgow, UK
| | - Susan Currie
- Biomedical Engineering, University of Strathclyde, Glasgow, UK
| |
Collapse
|
55
|
Hu MJ, He JL, Tong XR, Yang WJ, Zhao HH, Li GA, Huang F. Associations between essential microelements exposure and the aggressive clinicopathologic characteristics of papillary thyroid cancer. Biometals 2021; 34:909-921. [PMID: 33961183 DOI: 10.1007/s10534-021-00317-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Accepted: 04/29/2021] [Indexed: 02/06/2023]
Abstract
Aim of this study was to evaluate the association between multiple essential microelements exposure and the aggressive clinicopathologic characteristics of papillary thyroid carcinoma (PTC). The concentrations of 10 essential microelements in urine [cobalt (Co), chromium (Cr), copper (Cu), iron (Fe), manganese (Mn), molybdenum (Mo), selenium (Se), strontium (Sr), zinc (Zn), and iodine (I)] were measured in 608 patients newly diagnosed with PTC, including 154 males and 454 females. Chi square test and Wilcoxon rank sum test were used to compare general characteristics among males and females. Multivariate logistic regression was used to evaluate the associations between essential microelements and PTC clinicopathologic characteristics in single- and multi-microelement models. In this study, we only observed that the frequency of lymph node metastasis in males was higher than in females, and males had higher levels of zinc than females, but males had lower levels of iodine than females. It was found that high levels of Fe were associated with decreased risk of PTC tumor size > 1 cm, capsular invasion, and advanced T stage (T3/4a/4b). High levels of Co and Mo were associated with decreased risk of capsular invasion and lymph node metastasis, respectively. However, high levels of Mn and Sr were associated with increased risk of capsular invasion and multifocality respectively, and both were associated with increased risk of advanced T stage (T3/4a/4b). These findings indicated that certain essential microelements might have potential effects on PTC progression and aggressiveness. Further studies are required to confirm these findings.
Collapse
Affiliation(s)
- Ming-Jun Hu
- Department of Epidemiology and Biostatistics, School of Public Health, Anhui Medical University, Hefei, 230032, Anhui, China
| | - Jia-Liu He
- Department of Epidemiology and Biostatistics, School of Public Health, Anhui Medical University, Hefei, 230032, Anhui, China
| | - Xin-Ran Tong
- Second Department of Clinical Medicine, Anhui Medical University, Hefei, 230032, Anhui, China
| | - Wan-Jun Yang
- Department of Epidemiology and Biostatistics, School of Public Health, Anhui Medical University, Hefei, 230032, Anhui, China
| | - Huan-Huan Zhao
- Department of Epidemiology and Biostatistics, School of Public Health, Anhui Medical University, Hefei, 230032, Anhui, China
| | - Guo-Ao Li
- Department of Epidemiology and Biostatistics, School of Public Health, Anhui Medical University, Hefei, 230032, Anhui, China
| | - Fen Huang
- Department of Epidemiology and Biostatistics, School of Public Health, Anhui Medical University, Hefei, 230032, Anhui, China. .,Laboratory for Environmental Toxicology, Anhui Medical University, Hefei, 230032, Anhui, China.
| |
Collapse
|
56
|
Abstract
» The true incidence of pseudotumors in association with total joint arthroplasty is underestimated. » Pseudotumors occur with metal-on-metal, metal-on-polyethylene, and metal-on-ceramic articulations. » Metal ion levels should not be the only factor in decision-making regarding revision surgery. » Revision surgery is only indicated in symptomatic patients with clinical and radiographic findings and elevated metal ion levels. » Revision to a non-metal articulation is strongly suggested.
Collapse
|
57
|
Torre M, Genova Gaia L, Calevo MG, Wong M, Raso M, Barco S, Di Gaudio F, Cangemi G. Blood metal levels after minimally invasive repair of pectus excavatum. Interact Cardiovasc Thorac Surg 2021; 33:76-81. [PMID: 33686408 DOI: 10.1093/icvts/ivab052] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 12/01/2020] [Accepted: 12/12/2020] [Indexed: 11/14/2022] Open
Abstract
OBJECTIVES Minimally invasive repair of pectus excavatum (MIRPE) is the most popular surgical approach for paediatric patients with pectus excavatum. A substernal stainless still bar is inserted and left in place for 3 years and then removed. Our goal was to investigate blood metal levels after MIRPE and to correlate them with surgical details, such as the numbers of bars and stabilizers and the length of time the bar was in place. METHODS Blood levels of iron, chromium, manganese, molybdenum and nickel were analysed in 130 teenagers (108 boys and 22 girls) who had MIRPE using inductively coupled plasma mass spectrometry. A total of 62 patients were operated on using MIRPE (study group) and 68 patients were evaluated at implant time (control group). Differences between the numbers of bars implanted and the presence or absence of stabilizers were also considered. RESULTS Significant increases in the levels of abnormal chromium were found in patients in the study group compared with the controls (P = 0.02). When we compared the group of patients with 2 or more bars with the group with 1 bar, the percentage of patients with a value above the threshold increased by 29 (P = 0.05). A significant increase in chromium levels was observed in patients with stabilizers (P = 0.03). Above-threshold levels of molybdenum were found in 5.1% of patients in the control group, but the number was not statistically significant (P = 0.09). CONCLUSIONS We demonstrated that stainless steel devices used in MIRPE can elevate blood metal levels in paediatric patients. Moreover, we demonstrated that the use of metal stabilizers is associated with higher metal levels, probably due to increased dispersion.
Collapse
Affiliation(s)
- Michele Torre
- Pediatric Thoracic and Airway Surgery Unit, IRCCS Istituto Giannina Gaslini, Genova, Italy.,Department of Pediatric Surgery, IRCCS Istituto Giannina Gaslini, Genova, Italy
| | - Luca Genova Gaia
- Department of Pediatric Surgery, IRCCS Istituto Giannina Gaslini, Genova, Italy
| | - Maria Grazia Calevo
- Epidemiology and Biostatistics Unit, IRCCS Istituto Giannina Gaslini, Genova, Italy
| | - Michela Wong
- Department of Pediatric Surgery, IRCCS Istituto Giannina Gaslini, Genova, Italy
| | - Maria Raso
- Chromatography and Mass Spectrometry Section, Quality Control and Chemical Risk (CQRC), Department PROMISE, University Palermo, Palermo, Italy
| | - Sebastiano Barco
- Chromatography and Mass Spectrometry Section, Central Laboratory of Analyses, IRCCS Istituto Giannina Gaslini, Genoa, Italy
| | - Francesca Di Gaudio
- Chromatography and Mass Spectrometry Section, Quality Control and Chemical Risk (CQRC), Department PROMISE, University Palermo, Palermo, Italy
| | - Giuliana Cangemi
- Chromatography and Mass Spectrometry Section, Central Laboratory of Analyses, IRCCS Istituto Giannina Gaslini, Genoa, Italy
| |
Collapse
|
58
|
Son JS, Hwang EJ, Kwon LS, Ahn YG, Moon BK, Kim J, Kim DH, Kim SG, Lee SY. Antibacterial Activity of Propolis-Embedded Zeolite Nanocomposites for Implant Application. MATERIALS 2021; 14:ma14051193. [PMID: 33802544 PMCID: PMC7961988 DOI: 10.3390/ma14051193] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 02/19/2021] [Accepted: 02/24/2021] [Indexed: 11/25/2022]
Abstract
This study investigates the potential of propolis-embedded zeolite nanocomposites for dental implant application. Propolis-embedded zeolite nanocomposites were fabricated by complexation of propolis and zeolites. Then, they were pelleted with Poly(L-lactide) (PLA)/poly(ε-caprolactone) (PCL) polymer for the fabrication of a dental implant. The chemical properties of propolis were not changed during the fabrication of propolis-embedded zeolite nanocomposites in attenuated total reflection-fourier transform infra-red (ATR FT-IR) spectroscopy measurements. Propolis was continuously released from propolis-embedded zeolite nanocomposites over one month. PLA/PCL pellets containing propolis-embedded zeolite nanocomposites showed longer sustained release behavior compared to propolis-embedded zeolite nanocomposites. Propolis-embedded zeolite nanocomposite powder showed similar antibacterial activity against C. albicans in an agar plate and formed an inhibition zone as well as chlorohexidine (CHX) powder. Eluted propolis solution from PLA/PCL pellets also maintained antibacterial activity as well as CHX solution. Furthermore, eluted propolis solution from PLA/PCL pellets showed significant antibacterial efficacy against C. albicans, S. mutans and S. sobrinus. Dental implants fabricated from PLA/PCl polymer and propolis-embedded zeolite nanocomposites also have antibacterial efficacy and negligible cytotoxicity against normal cells. We suggest that PLA/PCl pellets containing propolis-embedded zeolite nanocomposites are promising candidates for dental implants.
Collapse
Affiliation(s)
- Jun Sik Son
- IT-Bio Material Research Team, Korea Textile Development Institute, Daegu 41842, Korea;
| | - Eun Ju Hwang
- Smart Medical Convergence Technology Support Center, Chosun University, Gwangju 61012, Korea; (E.J.H.); (Y.-G.A.); (B.-K.M.)
| | - Lee Seong Kwon
- RAPHA BIO Co. Ltd., Wanju-Gun, Jeollabuk-do 55367, Korea;
| | - Yong-Gook Ahn
- Smart Medical Convergence Technology Support Center, Chosun University, Gwangju 61012, Korea; (E.J.H.); (Y.-G.A.); (B.-K.M.)
| | - Byung-Kwon Moon
- Smart Medical Convergence Technology Support Center, Chosun University, Gwangju 61012, Korea; (E.J.H.); (Y.-G.A.); (B.-K.M.)
| | - Jin Kim
- Dental Healthcare & Clinical Trial Center, Chosun University, Gwangju 61452, Korea;
| | - Douk Hoon Kim
- Research Center, Medical Division, Nexturn Co. Ltd., Gyeonggi-do 17086, Korea;
| | - Su Gwan Kim
- Sangmu Su Dental Clinic, Gwangju 61998, Korea
- Correspondence: (S.G.K.); (S.-Y.L.); Tel.: +82-629-737-662 (S.-Y.L.); Fax: +82-629-737-662 (S.-Y.L.)
| | - Sook-Young Lee
- Smart Medical Convergence Technology Support Center, Chosun University, Gwangju 61012, Korea; (E.J.H.); (Y.-G.A.); (B.-K.M.)
- Regional Innovation Center for Dental Science & Engineering, Chosun University, Gwangju 61452, Korea
- Correspondence: (S.G.K.); (S.-Y.L.); Tel.: +82-629-737-662 (S.-Y.L.); Fax: +82-629-737-662 (S.-Y.L.)
| |
Collapse
|
59
|
Course of Metal Ions after a Revision of Malfunctioning Metal-on-Metal Total Hip Prostheses. ACTA ACUST UNITED AC 2021; 57:medicina57020115. [PMID: 33525335 PMCID: PMC7912175 DOI: 10.3390/medicina57020115] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Revised: 01/25/2021] [Accepted: 01/26/2021] [Indexed: 12/16/2022]
Abstract
The present research evaluated the course of cobalt and chromium in the blood and urine after the revision of metal-on-metal with a ceramic-on-polyethylene total hip arthroplasty. Seven patients were enrolled for hip prosthesis revision owing to ascertained damage of the implant. Metals in the blood and urine were evaluated before and after the hip revision. The double measurement before the total hip revision revealed high levels of metal ions (on average, 88.1 µg/L of cobalt in the blood, 399.0 µg/g of creatinine cobalt in the urine, 46.8 µg/L of chromium in the blood, and 129.6 µg/g of creatinine chromium in the urine at the first measurements), with an increasing trend between the first and second dosage. Within a week after the hip revision, the levels of metal ions significantly decreased by approximately half. Four to six months after the operation, the cobalt levels were found near to the reference values, whereas the chromium levels reached 25% of the values measured before the revision. The revision of malfunctioning metal-on-metal implants produced a dramatic decrease of metal ions in biological fluids, although it did not completely rescue the chromium level.
Collapse
|
60
|
Büchner M, Cook RB, Dommann-Scherrer C, Meier C, Dommann A, Wahl P. It's worth cleaning - The examination of the female taper could identify a particular cause of trunnionosis at revision 16 years after total hip arthroplasty. J Mech Behav Biomed Mater 2021; 115:104304. [PMID: 33445103 DOI: 10.1016/j.jmbbm.2020.104304] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2020] [Revised: 11/28/2020] [Accepted: 12/29/2020] [Indexed: 11/18/2022]
Abstract
Adverse reaction to metal debris (ARMD) is an issue in metal-on-metal (MoM) total hip replacements (THR). It mainly affects large-head MoM THR, whereas 28-32 mm MoM pairings are associated with low long-term revision rates. However, the bearing surface is not necessarily the only cause of metal debris. This report documents with advanced analysis of the retrievals a particular cause of trunnionosis in late failure of a small diameter MoM THR and illustrates the importance of cleaning of the taper when seating the head in THR. A 65-year-old patient was revised due to ARMD 16 years after small diameter MoM THR. Debridement and exchange of the inlay and the head had been performed through an anterior approach. While the cup and the outer surface of the head were accessible to direct analysis by an optical coordinate measuring machine, the female taper had to be analysed indirectly by measuring an imprint. Wear from the cup and the head was within expected low ranges. The analysis of the female taper identified bone fragments, which contributed to trunnionosis. Failure due to ARMD after MoM THR is not necessarily caused by the bearing, but can be due to trunnionosis. Bone fragments within the taper contact in this case highlight the importance of meticulous cleaning of the taper before seating the head, to avoid trunnionosis.
Collapse
Affiliation(s)
- Mara Büchner
- Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland
| | - Richard B Cook
- National Centre for Advanced Tribology at Southampton, University of Southampton, Southampton, United Kingdom
| | | | - Christoph Meier
- Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland
| | - Alex Dommann
- EMPA Swiss Federal Laboratories for Material Science and Technology, St. Gallen, Switzerland; ARTORG Centre for Biomedical Engineering Research, University of Berne, Berne, Switzerland
| | - Peter Wahl
- Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland.
| |
Collapse
|
61
|
Sánchez-Dalmau BF, Spencer F, Sánchez-Vela L, Camós-Carreras A, Nogué Xarau S, Fernández-Valencia JA. Visual impairment induced by prosthetic cobaltism. ARCHIVOS DE LA SOCIEDAD ESPAÑOLA DE OFTALMOLOGÍA 2020; 96:316-320. [PMID: 34092285 DOI: 10.1016/j.oftale.2020.06.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Accepted: 06/18/2020] [Indexed: 11/19/2022]
Abstract
The case of a 68-year-old patient with visual loss secondary to prosthetic cobaltism is reported. The degeneration of the metallic hip prosthesis can produce a systemic absorption of cobalt with cardiac, neurological, endocrine, auditory, and visual manifestations. The diagnostic suspicion is confirmed by serum cobalt measurements. Treatment with early surgery and chelating agents can lead to improvement of the visual, and the other disorders.
Collapse
Affiliation(s)
| | - F Spencer
- Institut Clínic d'Oftalmología, Hospital Clínic, Barcelona, Spain
| | - L Sánchez-Vela
- Servicio de Oftalmología, Hospital Universitari Vall d'Hebrón, Barcelona, Spain
| | - A Camós-Carreras
- Institut Clínic d'Oftalmología, Hospital Clínic, Barcelona, Spain
| | - S Nogué Xarau
- Servicio de Toxicología de Urgencias, Hospital Clínic, Barcelona, Spain
| | | |
Collapse
|
62
|
Homma Y, Morikawa T, Ishii S, Baba T, Kaneko K. Bowing-head sign: rare but detectable in pre-catastrophic hip implant failure. Arch Orthop Trauma Surg 2020; 140:2085-2089. [PMID: 32940804 DOI: 10.1007/s00402-020-03609-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2020] [Accepted: 09/09/2020] [Indexed: 11/24/2022]
Abstract
Recently, catastrophic failure (i.e., dissociation between the metal femoral head and stem due to stem neck deformation) after total hip arthroplasty (THA) has been reported. Early detection of this complication is very important, because it is accompanied by an increased cobalt concentration in the body, which might influence systemic conditions such as heart failure and immune system diseases. However, early detection of stem neck deformation is considered as difficult. In most cases in the literatures, the diagnosis was made at the time of acute dissociation. We report a case of early detection of stem neck deformation with the 'Bowing-head sign' before acute dissociation. The patient is a 71-year old woman complained of a clicking sensation in the right hip during regular follow-up after THA with a 32-mm cobalt/chromium head with polyethylene insert for osteoarthritis performed 7 years previously. The plain radiograph showed that the angle between the metal femoral head and the axis of the stem neck was not perpendicular ('Bowing-head sign'). Dynamic evaluation under fluoroscopy showed movement of the stem neck in the metal femoral head with hip abduction and adduction. Laboratory data showed abnormal serum cobalt (6.3 μg/L, normal < 1 μg/L) and chromium (3.8 μg/L, normal < 5 μg/L) levels. Considering those radiographic findings, deformation of the stem neck due to trunnionosis was diagnosed, and elective revision surgery was performed without any complications. Plain radiographs after THA should be assessed with attention to this complication, 'Bowing-head sign' must not be overlooked.
Collapse
Affiliation(s)
- Yasuhiro Homma
- Department of Orthopedic Surgery, Faculty of Medicine, Juntendo University, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan.
| | - Takahiro Morikawa
- Department of Orthopedic Surgery, Faculty of Medicine, Juntendo University, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Seiya Ishii
- Department of Orthopedic Surgery, Faculty of Medicine, Juntendo University, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Tomonori Baba
- Department of Orthopedic Surgery, Faculty of Medicine, Juntendo University, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Kazuo Kaneko
- Department of Orthopedic Surgery, Faculty of Medicine, Juntendo University, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| |
Collapse
|
63
|
Xue R, Wang D, Yang D, Zhang L, Xu X, Liu L, Wu D. Novel Biocompatible Zr-Based Alloy with Low Young's Modulus and Magnetic Susceptibility for Biomedical Implants. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E5130. [PMID: 33202987 PMCID: PMC7696516 DOI: 10.3390/ma13225130] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Revised: 11/10/2020] [Accepted: 11/11/2020] [Indexed: 11/25/2022]
Abstract
The microstructure, mechanical properties, magnetic susceptibility, electrochemical corrosion performance, in vitro cell compatibility and blood consistency of Zr-16Nb-xTi (x = 0, 4, 8, 12 and 16 wt.%) materials were investigated as potential materials for biomedical implants. X-ray diffraction (XRD) and Transmission electron microscopy (TEM) analyses revealed the secondary phase martensite α' formed during the quenching process. The phase composition contained metastable β and martensite α', resulting from Ti addition. These phase constitutions were the main causes of a low Young's modulus and magnetic susceptibility. The in vitro cytocompatibility analysis illustrated that the MG63 cells maintained high activity (from 91% to 97%) after culturing in Zr-16Nb-xTi extraction media for 12 days due to the high internal biocompatibility of Zr, Nb and Ti elements, as well as the optimal corrosion resistance of Zr-16Nb-xTi. On the basis of Inductively coupled plasma optical emission spectrometry (ICP-OES) ion release studies, the concentration of Zr, Nb and Ti was noted to reach the equipment detective limit of 0.001 mg/L, which was much lower than pure Ti. With respect to the corrosion behavior in Hank's solution, Zr-16Nb-16Ti displayed superior properties, possessing the lowest corrosion current density and widest passivation region, attributed to the addition of Ti. The blood compatibility test illustrated that the Zr-16Nb-xTi materials were nonhemolytic, and the platelets maintained a spherical shape, with no aggregation or activation on Zr-16Nb-xTi. Overall, Ti addition has obvious effects on the developed Zr-16Nb-xTi alloys, and Zr-16Nb-4Ti exhibited low magnetic susceptibility, low modulus, good biocompatibility and proper corrosion properties, demonstrating the potential of use as implant biomaterials.
Collapse
Affiliation(s)
- Renhao Xue
- School of Material Science and Engineering, Central South University, Changsha 410083, China; (R.X.); (D.W.); (L.Z.); (X.X.)
- State Key Laboratory of Powder Metallurgy, Central South University, Changsha 410083, China
| | - Dong Wang
- School of Material Science and Engineering, Central South University, Changsha 410083, China; (R.X.); (D.W.); (L.Z.); (X.X.)
- State Key Laboratory of Powder Metallurgy, Central South University, Changsha 410083, China
| | - Dawei Yang
- Centre for Medical Genetics and School of Life Science, Central South University, Changsha 410008, China;
| | - Ligang Zhang
- School of Material Science and Engineering, Central South University, Changsha 410083, China; (R.X.); (D.W.); (L.Z.); (X.X.)
- State Key Laboratory of Powder Metallurgy, Central South University, Changsha 410083, China
| | - Xiaoning Xu
- School of Material Science and Engineering, Central South University, Changsha 410083, China; (R.X.); (D.W.); (L.Z.); (X.X.)
- State Key Laboratory of Powder Metallurgy, Central South University, Changsha 410083, China
| | - Libin Liu
- School of Material Science and Engineering, Central South University, Changsha 410083, China; (R.X.); (D.W.); (L.Z.); (X.X.)
- State Key Laboratory of Powder Metallurgy, Central South University, Changsha 410083, China
| | - Di Wu
- School of Material Science and Engineering, Central South University, Changsha 410083, China; (R.X.); (D.W.); (L.Z.); (X.X.)
- State Key Laboratory of Powder Metallurgy, Central South University, Changsha 410083, China
- School of Metallurgy and Environment, Central South University, Changsha 410083, China
| |
Collapse
|
64
|
Taterra D, Skinningsrud B, Pękala PA, Tomaszewska IM, Marycz K, Radomski MW, Tomaszewski KA. In vitro effects of cobalt and chromium nanoparticles on human platelet function. Nanotoxicology 2020; 15:52-65. [PMID: 33147415 DOI: 10.1080/17435390.2020.1841845] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Nanoparticles (NPs) are released from orthopedic and neurosurgical prostheses and can interact with a number of blood components once in the bloodstream. Potential toxic effects of Co and Cr NPs on blood platelets have not been thoroughly investigated. The aim of this study was to analyze the effect of Co and Cr NPs on platelet function in vitro. The ability of the tested NPs to induce platelet activation and aggregation was measured using light transmission aggregometry, flow cytometry, and quartz crystal balance with dissipation (QCM-D). This was confirmed by transmission electron microscopy (TEM), scanning electron microscopy, and optical and immunofluorescence microscopy. Perfusion of QCM-D sensor crystals with platelet-rich-plasma in the presence of Co 28 nm, CoO 50 nm, Co2O3 50 nm, Co3O4 30-50nm, Cr 35-45nm, Cr2O3 60 nm NPs (0.5-5.0 µg/mL) resulted in significant changes in frequency and dissipation, indicating that these NPs caused platelet microaggregation. Transmission electron microscopy also revealed that Cr NPs led to platelet swelling and lysis. Our study shows that both Co and Cr NPs affect platelet function in vitro with two distinct mechanisms. While Co NPs result in standard platelet aggregation, Cr NPs cause both platelet aggregation and decreased platelet membrane integrity and lysis. Based on these findings, monitoring serum NP levels and platelet-mediated hemostasis can be advised in patients with metal-on-metal Co-Cr prostheses.
Collapse
Affiliation(s)
- Dominik Taterra
- Department of Anatomy, Jagiellonian University Medical College, Krakow, Poland.,International Evidence-Based Anatomy Working Group, Krakow, Poland
| | - Bendik Skinningsrud
- Department of Anatomy, Jagiellonian University Medical College, Krakow, Poland.,International Evidence-Based Anatomy Working Group, Krakow, Poland
| | - Przemysław A Pękala
- Department of Anatomy, Jagiellonian University Medical College, Krakow, Poland.,International Evidence-Based Anatomy Working Group, Krakow, Poland
| | - Iwona M Tomaszewska
- Department of Medical Education, Jagiellonian University Medical College, Krakow, Poland
| | - Krzysztof Marycz
- International Institute of Translational Medicine, Malin, Poland.,Faculty of Biology and Animal Science, Department of Experimental Biology, University of Environmental and Life Sciences Wroclaw, Wroclaw, Poland.,Faculty of Veterinary Medicine, Clinic for Horses - Department for Surgery, Justus-Liebig-University, Gießen, Germany
| | - Marek W Radomski
- Department of Anatomy, Physiology and Pharmacology, College of Medicine, University of Saskatchewan, Saskatoon, Canada
| | - Krzysztof A Tomaszewski
- Department of Anatomy, Jagiellonian University Medical College, Krakow, Poland.,Faculty of Medicine and Health Sciences, Andrzej Frycz Modrzewski Krakow University, Krakow, Poland.,Scanmed St. Raphael Hospital, Krakow, Poland
| |
Collapse
|
65
|
Schoon J, Hesse B, Rakow A, Ort MJ, Lagrange A, Jacobi D, Winter A, Huesker K, Reinke S, Cotte M, Tucoulou R, Marx U, Perka C, Duda GN, Geissler S. Metal-Specific Biomaterial Accumulation in Human Peri-Implant Bone and Bone Marrow. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2020; 7:2000412. [PMID: 33101844 PMCID: PMC7578891 DOI: 10.1002/advs.202000412] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 06/09/2020] [Indexed: 05/13/2023]
Abstract
Metallic implants are frequently used in medicine to support and replace degenerated tissues. Implant loosening due to particle exposure remains a major cause for revision arthroplasty. The exact role of metal debris in sterile peri-implant inflammation is controversial, as it remains unclear whether and how metals chemically alter and potentially accumulate behind an insulating peri-implant membrane, in the adjacent bone and bone marrow (BM). An intensively focused and bright synchrotron X-ray beam allows for spatially resolving the multi-elemental composition of peri-implant tissues from patients undergoing revision surgery. In peri-implant BM, particulate cobalt (Co) is exclusively co-localized with chromium (Cr), non-particulate Cr accumulates in the BM matrix. Particles consisting of Co and Cr contain less Co than bulk alloy, which indicates a pronounced dissolution capacity. Particulate titanium (Ti) is abundant in the BM and analyzed Ti nanoparticles predominantly consist of titanium dioxide in the anatase crystal phase. Co and Cr but not Ti integrate into peri-implant bone trabeculae. The characteristic of Cr to accumulate in the intertrabecular matrix and trabecular bone is reproducible in a human 3D in vitro model. This study illustrates the importance of updating the view on long-term consequences of biomaterial usage and reveals toxicokinetics within highly sensitive organs.
Collapse
Affiliation(s)
- Janosch Schoon
- Julius Wolff InstituteCharité – Universitätsmedizin BerlinBerlin13353Germany
- Berlin Institute of Health Center for Regenerative TherapiesBerlin Institute of HealthBerlin10178Germany
- Berlin‐Brandenburg School for Regenerative TherapiesCharité – Universitätsmedizin BerlinBerlin13353Germany
| | - Bernhard Hesse
- Xploraytion GmbHBerlin10625Germany
- European Synchrotron Radiation FacilityGrenoble38000France
| | - Anastasia Rakow
- Berlin Institute of Health Center for Regenerative TherapiesBerlin Institute of HealthBerlin10178Germany
- Center for Musculoskeletal SurgeryCharité – Universitätsmedizin BerlinBerlin10117Germany
| | - Melanie J. Ort
- Julius Wolff InstituteCharité – Universitätsmedizin BerlinBerlin13353Germany
- Berlin Institute of Health Center for Regenerative TherapiesBerlin Institute of HealthBerlin10178Germany
- Berlin‐Brandenburg School for Regenerative TherapiesCharité – Universitätsmedizin BerlinBerlin13353Germany
| | - Adrien Lagrange
- Xploraytion GmbHBerlin10625Germany
- Department of Materials Science and EngineeringInstitute of Materials Science and TechnologiesTechnische Universität BerlinBerlin10623Germany
| | - Dorit Jacobi
- Julius Wolff InstituteCharité – Universitätsmedizin BerlinBerlin13353Germany
- Berlin Institute of Health Center for Regenerative TherapiesBerlin Institute of HealthBerlin10178Germany
| | | | - Katrin Huesker
- Endocrinology and Immunology DepartmentInstitute for Medical DiagnosticsBerlin12247Germany
| | - Simon Reinke
- Julius Wolff InstituteCharité – Universitätsmedizin BerlinBerlin13353Germany
- Berlin Institute of Health Center for Regenerative TherapiesBerlin Institute of HealthBerlin10178Germany
| | - Marine Cotte
- European Synchrotron Radiation FacilityGrenoble38000France
- CNRSLaboratoire d'archéologie moléculaire et structuraleLAMSSorbonne UniversitéParis75005France
| | - Remi Tucoulou
- European Synchrotron Radiation FacilityGrenoble38000France
| | | | - Carsten Perka
- Berlin Institute of Health Center for Regenerative TherapiesBerlin Institute of HealthBerlin10178Germany
- Berlin‐Brandenburg School for Regenerative TherapiesCharité – Universitätsmedizin BerlinBerlin13353Germany
- Center for Musculoskeletal SurgeryCharité – Universitätsmedizin BerlinBerlin10117Germany
| | - Georg N. Duda
- Julius Wolff InstituteCharité – Universitätsmedizin BerlinBerlin13353Germany
- Berlin Institute of Health Center for Regenerative TherapiesBerlin Institute of HealthBerlin10178Germany
- Berlin‐Brandenburg School for Regenerative TherapiesCharité – Universitätsmedizin BerlinBerlin13353Germany
| | - Sven Geissler
- Julius Wolff InstituteCharité – Universitätsmedizin BerlinBerlin13353Germany
- Berlin Institute of Health Center for Regenerative TherapiesBerlin Institute of HealthBerlin10178Germany
- Berlin‐Brandenburg School for Regenerative TherapiesCharité – Universitätsmedizin BerlinBerlin13353Germany
| |
Collapse
|
66
|
Rakow A, Schoon J. Systemic Effects of Metals Released from Arthroplasty Implants – a Brief Summary. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE 2020; 158:501-507. [DOI: 10.1055/a-1187-1751] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
AbstractIn recent years, increasing concern has been raised regarding potential systemic toxicity of metals released from arthroplasty implants. A lack of valid metal thresholds for human (organ) toxicity and the prospect of multi-decade survival of modern hip and knee replacements pose special challenges. Indeed, evidence of systemic effects of metals released from such implants is largely missing. Systemic cobalt exposure has repeatedly been associated with cardiotoxic and neurotoxic effects, and also with thyroid dysfunction. The toxic potential of chromium is considered less pronounced. Yet, in arthroplasty there is usually a co-exposure to chromium and cobalt which complicates evaluation of element-specific effects. Toxicity of titanium dioxide nanoparticles has been subject to debate among international regulatory authorities. Their wide use in a variety of products in everyday life, such as toothpaste, cosmetics and food colorants, hampers the assessment of an
arthroplasty-induced systemic titanium exposure. To date there is no clear evidence for systemic complications due to titanium dioxide released from arthroplasty implants. Release of further metals such as tantalum, niobium, nickel, vanadium and zirconium from hip and knee replacement implants has been described occasionally, but systemic effects of respective long-term exposure scenarios are unknown. Generally, the characterization of all released metals regarding their chemical and physical specifications is critical for the evaluation of potential systemic risks. Systematic studies investigating the accumulation of metals relevant in arthroplasty in different organs/organ systems and the biological consequences of such accumulations are urgently needed.
Collapse
Affiliation(s)
- Anastasia Rakow
- Center for Musculoskeletal Surgery, Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Berlin, Germany
- Berlin Institute of Health Center for Regenerative Therapies, Berlin, Germany
| | - Janosch Schoon
- Klinik und Poliklinik für Orthopädie und Orthopädische Chirurgie, Universitätsmedizin Greifswald, Germany
- Julius Wolff Institute, Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Berlin, Germany
| |
Collapse
|
67
|
Kumar A, Zaidi SMH, Sahito B, Kumar D, Ali M. A Case Report of Metallosis With a Failed Distal Femur Plate. Cureus 2020; 12:e10361. [PMID: 33062484 PMCID: PMC7549848 DOI: 10.7759/cureus.10361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Metallosis is a very rare condition that poses a diagnostic challenge. Its precise incidence is not known and the condition should be suspected in patients who present with the clinical signs and symptoms discussed below. In particular, physicians and surgeons should pay special attention to whether metal prosthesis has been used for fracture repair or joint function. Here we report the case of a 40-year-old male who presented at an orthopedic surgery outpatient department in a tertiary care hospital with pain in the right distal thigh that had been ongoing for three months and swelling that had been ongoing for two months. According to the patient, he had received an operation for a right-sided distal femur fracture that was fixed with plate at a different hospital one year prior. Despite receiving all the appropriate physical exams and labs, and getting a radiologic workup, the diagnosis was unclear, and ultimately surgical exploration was conducted, which led to the diagnosis of metallosis. Although metallosis is a well-known complication, due to its rarity, physicians and surgeons often forget to keep metallosis as a differential that leads to diagnostic difficulties.
Collapse
Affiliation(s)
- Akshay Kumar
- Internal Medicine, Civil Hospital Karachi, Dow University of Health Sciences, Karachi, PAK
| | | | - Badaruddin Sahito
- Orthopaedic Surgery, Civil Hospital Karachi, Dow University of Health Sciences, Karachi, PAK
| | - Dileep Kumar
- Orthopaedic Surgery, Civil Hospital Karachi, Dow University of Health Sciences, Karachi, PAK
| | - Maratib Ali
- Orthopaedic Surgery, Civil Hospital Karachi, Dow University of Health Sciences, Karachi, PAK
| |
Collapse
|
68
|
Leyssens L, Vinck B, Van Der Straeten C, Dhooge I, Wuyts FL, Maes LK. The ototoxic potential of cobalt from metal-on-metal hip implants: a pilot study on the patient-reported auditory, vestibular, and general neurological outcome. Int J Audiol 2020; 60:44-53. [PMID: 32687006 DOI: 10.1080/14992027.2020.1789922] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
OBJECTIVE This study aimed to systematically investigate the ototoxic potential of cobalt in patients with a metal-on-metal (MoM) hip implant, using objective auditory and vestibular assessments and a questionnaire. The results of the objective evaluation were published previously, whereas the current study focused on the questionnaire outcome and its relationship to the blood cobalt level. Design and study sample: Twenty patients (33-65 years) with a primary MoM hip implant and 20 non-implanted control subjects, matched for age, gender, and noise exposure, received a questionnaire to evaluate the presence of several hearing and balance symptoms (part 1) and general neurological issues (part 2). RESULTS Concerning part 1, the proportion of auditory-related symptoms in general (p = 0.022) and tinnitus (p = 0.047) was significantly higher in the MoM patient group, whereas no group difference was found for hyperacusis, increased listening effort, and decreased speech understanding. Concerning part 2, no significant group differences were detected. Within the MoM patient group, the questionnaire outcome was not significantly different between the low-exposure and high-exposure subgroups according to the blood Co level. CONCLUSIONS In line with our previous study, these results potentially imply Co-induced impairment to the auditory system, despite the lack of a clear dose-response relationship.
Collapse
Affiliation(s)
- Laura Leyssens
- Department of Rehabilitation Sciences, Faculty of Medicine and Health Sciences, University of Ghent, Ghent, Belgium
| | - Bart Vinck
- Department of Rehabilitation Sciences, Faculty of Medicine and Health Sciences, University of Ghent, Ghent, Belgium.,Department of Speech-Language Pathology and Audiology, University of Pretoria, Pretoria, South Africa
| | | | - Ingeborg Dhooge
- Department of Ear Nose Throat, Ghent University Hospital, Ghent, Belgium
| | - Floris L Wuyts
- Lab for Equilibrium Investigations and Aerospace, University of Antwerp, Antwerp, Belgium
| | - Leen K Maes
- Department of Rehabilitation Sciences, Faculty of Medicine and Health Sciences, University of Ghent, Ghent, Belgium
| |
Collapse
|
69
|
Crainic AM, Callisti M, van Veelen A, Michalik A, Milton JA, Palmer MR, Cook RB. A comparative study on the physicochemical characteristics of nanoparticles released in vivo from CoCrMo tapers and cement-stem interfaces of total hip replacements. J Biomed Mater Res B Appl Biomater 2020; 108:3311-3322. [PMID: 32596955 DOI: 10.1002/jbm.b.34667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Revised: 04/24/2020] [Accepted: 05/25/2020] [Indexed: 11/09/2022]
Abstract
The good biocompatibility and corrosion resistance of the bulk CoCrMo alloy has resulted in it being used in the manufacture of implants and load bearing medical devices. These devices, however, can release wear and corrosion products which differ from the composition of the bulk CoCrMo alloy. The physicochemical characteristics of the particles and the associated in vivo reactivity are dictated by the wear mechanisms and electrochemical conditions at the sites of material loss. Debris released from CoCrMo hip bearings, taper junctions, or cement-stem interfaces can, therefore, have different chemical and morphological characteristics, which provide them with different in vivo toxicities. Here, we propose to assess and compare the characteristics of the particles released in vivo from CoCrMo tapers and cement-stem interfaces which have received less attention compared to debris originating from the hip bearings. The study uses state-of-art characterization techniques to provide a detailed understanding of the size, morphology, composition, and chemistry of the particles liberated from the wear and corrosion flakes from revised hip replacements, with an enzymatic treatment. The phase analyses identified Cr2 O3 nanoparticles released from tapers and cement-stem interfaces, whose composition did not vary with origin or particle morphology. The size distributions showed significantly smaller particles were released from the stems, compared to the particles originating from the corresponding tapers. The investigation demonstrates that the tribocorrosive processes occurring at the taper and stem interfaces both result in Cr2 O3 nanoparticle formation.
Collapse
Affiliation(s)
- Alina M Crainic
- National Centre for Advanced Tribology at Southampton (nCATS), University of Southampton, Southampton, UK
| | - Mauro Callisti
- National Centre for Advanced Tribology at Southampton (nCATS), University of Southampton, Southampton, UK.,Department of Materials Science and Metallurgy, Cambridge University, Cambridge, UK
| | - Arjen van Veelen
- Material Science and Technology Division, Material Science and Technology Division, Los Alamos, NM 87545, UK.,Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, CA, 94025
| | - Agnes Michalik
- National Oceanography Centre Southampton (NOCS), University of Southampton, School of Ocean and Earth Science, Southampton, UK
| | - James A Milton
- National Oceanography Centre Southampton (NOCS), University of Southampton, School of Ocean and Earth Science, Southampton, UK
| | - Martin R Palmer
- National Oceanography Centre Southampton (NOCS), University of Southampton, School of Ocean and Earth Science, Southampton, UK
| | - Richard B Cook
- National Centre for Advanced Tribology at Southampton (nCATS), University of Southampton, Southampton, UK
| |
Collapse
|
70
|
Grulli F, Lonati D, Ronchi A, Perotti F, Spinillo A, Locatelli CA. Management of high concentrations of cobalt and chromium in blood due to metal-on-metal hip arthroplasty in a pregnant woman. Clin Toxicol (Phila) 2020; 59:72-73. [DOI: 10.1080/15563650.2020.1757694] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Affiliation(s)
- Francesca Grulli
- Resident physician in Emergency Medicine, University of Pavia, Pavia, Italy
| | - Davide Lonati
- Pavia Poison Control Centre – National Toxicology Information Centre – Clinical and Experimental Lab, Toxicology Unit, Maugeri Clinical and Scientific Institutes IRCCS and University of Pavia, Pavia, Italy
| | - Anna Ronchi
- Pavia Poison Control Centre – National Toxicology Information Centre – Clinical and Experimental Lab, Toxicology Unit, Maugeri Clinical and Scientific Institutes IRCCS and University of Pavia, Pavia, Italy
| | - Francesca Perotti
- Department of Obstetrics and Gynecology, University of Pavia, Pavia, Italy
| | - Arsenio Spinillo
- Department of Obstetrics and Gynecology, University of Pavia, Pavia, Italy
| | - Carlo A. Locatelli
- Pavia Poison Control Centre – National Toxicology Information Centre – Clinical and Experimental Lab, Toxicology Unit, Maugeri Clinical and Scientific Institutes IRCCS and University of Pavia, Pavia, Italy
| |
Collapse
|
71
|
Ferner RE, Aronson JK. Medical Devices: Classification and Analysis of Faults Leading to Harms. Drug Saf 2020; 43:95-102. [PMID: 31691257 DOI: 10.1007/s40264-019-00879-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
INTRODUCTION Harms from medical devices are important, but have been much less well studied than adverse drug reactions. Information provided to device users is of variable quality. OBJECTIVE Our aim was to define "medical device fault" and "adverse effect of a medical device"; to establish whether medical device faults arise in design, manufacture, or use; and to consider ways of mitigating the adverse effects of medical devices. METHODS We analysed 100 consecutive faults reported by the US Food and Drug Administration (FDA) and 50 faults reported by the UK Medicines and Healthcare products Regulatory Agency (MHRA), and classified faults according to the point at which they occurred. RESULTS Nearly 70% of reported faults related to devices that entered the body. Over 70% arose at the design stage, a quarter of the faults were associated with manufacture, and less than 5% were primarily caused by faulty use. CONCLUSION We defined a medical device fault as an unintended failure in the design, manufacture, or use of a medical device that leads to, or has the potential to lead to, harm to the patient, and an adverse effect of a medical device as an unintended and appreciably harmful effect, caused by a medical device, which demonstrates a hazard of the device and may warrant preventive measures, or a change in the mode of use, or withdrawal of the device. Most faults that generate warnings arise from problems at the design stage, some arise at the manufacturing stage, and a few in usage. Careful assessment of the design of safety-critical devices in the light of previous problems may help to prevent repetition of errors. It would be helpful if, in addition to user manuals, manufacturers were required to produce Summaries of Device Characteristics (SDCs, "labels") that contained a systematically presented set of information about a product.
Collapse
Affiliation(s)
- Robin E Ferner
- West Midlands Centre for Adverse Drug Reactions, City Hospital, Birmingham, B18 7QH, UK. .,Institute of Clinical Sciences, University of Birmingham, Birmingham, UK. .,Insitute of Cardiovascular Medicine, University College London, London, UK.
| | - Jeffrey K Aronson
- West Midlands Centre for Adverse Drug Reactions, City Hospital, Birmingham, B18 7QH, UK.,Centre for Evidence Based Medicine, Nuffield Department of Primary Care Health Sciences, Oxford, OX2 6GG, UK
| |
Collapse
|
72
|
Arnaud J, Beauval N, Bost M, Fofou-Callierez MB, El Balkhi S, Garnier R, Lelièvre B, Romain S, Ropert Bouchet M, Sadeg N, Goullé JP. Intérêts d’inclure la détermination d’éléments inorganiques à la nomenclature des actes de biologie médicale. TOXICOLOGIE ANALYTIQUE ET CLINIQUE 2020. [DOI: 10.1016/j.toxac.2019.07.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
73
|
Self-reported systemic complaints in patients with metal-on-metal hip arthroplasty. J Orthop 2020; 18:213-217. [PMID: 32071507 DOI: 10.1016/j.jor.2020.01.032] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Accepted: 01/24/2020] [Indexed: 12/31/2022] Open
Abstract
Introduction An increase in blood serum metal ion levels is seen after implantation of all metal-on-metal (MoM) hip prosthesis. Systemic complaints contributed to raised cobalt ion concentrations in patients with MoM arthroplasty may lead to a variety of symptoms. The aim of this study is to investigate self-reported systemic complaints in association with cobalt ion concentrations in patients with any type of MoM hip prosthesis. Methods A cohort study was conducted. Patients with both unilateral and bilateral, resurfacing and large head metal on metal total hip arthroplasties (LHMoM THA) were included. Cobalt ion concentrations were measured by inductively coupled plasma mass spectrometry. Based on the known cobalt toxicity symptoms of case-reports and toxicology reports a new non-validated questionnaire was developed. Analysis was performed on two groups; a low cobalt ion concentration group and a high cobalt ion concentration group. Results A total of 62 patients were included with a mean age at surgery of 60.8 ± 9.3 years and a mean follow up of 6.3 ± 1.4 years. Mean cobalt ion concentrations were 104 ± 141 nmol/L (9-833). Based on the different thresholds (120-170 or 220 nmol/L) the low cobalt ion concentration group consisted of 44 (71%), 51 (82%) or 55 (89%) subjects respectively. In the 120 nmol/L and 170 nmol/L thresholds a significant difference in age was found. The composite score for OVS increased from 54% to 57%-68% with rising threshold value, a hint at the correlation between ion concentration and symptom prevalence. Discussion Ocular-vestibular symptoms were more common in high cobalt ion concentration groups for the three threshold levels tested and with increasing prevalence for higher threshold values. With regards to proactively inquired, self-reported symptoms the threshold where effects may be present could be lower than values currently applied in clinical follow-up.
Collapse
|
74
|
Garcia MD, Hur M, Chen JJ, Bhatti MT. Cobalt toxic optic neuropathy and retinopathy: Case report and review of the literature. Am J Ophthalmol Case Rep 2020; 17:100606. [PMID: 32025592 PMCID: PMC6997813 DOI: 10.1016/j.ajoc.2020.100606] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Revised: 12/29/2019] [Accepted: 01/03/2020] [Indexed: 01/19/2023] Open
Abstract
Purpose We detail a case of cobalt toxicity with visual and systemic complications, review the pathogenic process for the optic neuropathy and retinopathy, and discuss the controversy of metallic hip prosthesis. Observations A 59-year-old female with a history of multiple left hip arthroplasties presented to our clinic with bilateral visual loss. The year prior, she had failure of the hip implant necessitating revision surgery with placement of a chrome-cobalt head. A few months after surgery, she began experiencing blurred and “white, spotty” vision in both eyes in addition to hypothyroidism, cardiomyopathy and neuropathy. The possibility of the patient's symptoms being due to cobalt toxicity from her hip prosthesis was proposed and she was found to have a serum cobalt level >1000 μg/L (normal 0–0.9 ng/mL). Visual acuity was 20/600 in the right and 20/800 in the left eye. There was bilateral temporal optic disc pallor. Goldmann visual field testing demonstrated bilateral central scotomas, optical coherence tomography (OCT) showed severe ganglion cell layer-inner plexiform layer (GCLIPL) thinning and multifocal electroretinography (mfERG) demonstrated decreased amplitudes in both eyes. She underwent a total hip revision arthroplasty with extensive debridement of “black sludge” found within a pseudocapsule. Four days after surgery, cobalt serum levels had significantly decreased to 378 ng/mL. One month after surgery, she had significant improvement in visual acuity (20/150 right eye, 20/250 left eye), Goldmann visual field testing, and mfERG. OCT showed retinal nerve fiber thinning and persistent GCLIPL thinning in both eyes. Conclusions and Importance Excessive cobalt levels can result in systemic toxicity leading to visual changes, peripheral neuropathy, hearing loss, cognitive deficits, cardiomyopathy and hypothyroidism. In recent years it has become apparent that cobalt toxicity can be associated with metal-on-metal total hip arthroplasty, or the grinding effects of retained ceramic particles from a fractured ceramic head on a cobalt-chromium femoral head prosthesis.
Collapse
Affiliation(s)
- Maria D Garcia
- Department of Ophthalmology, Mayo Clinic College of Medicine, Rochester, MN, USA
| | - Minjun Hur
- Department of Ophthalmology, Mayo Clinic College of Medicine, Rochester, MN, USA
| | - John J Chen
- Department of Ophthalmology, Mayo Clinic College of Medicine, Rochester, MN, USA.,Department of Neurology, Mayo Clinic College of Medicine, Rochester, MN, USA
| | - M Tariq Bhatti
- Department of Ophthalmology, Mayo Clinic College of Medicine, Rochester, MN, USA.,Department of Neurology, Mayo Clinic College of Medicine, Rochester, MN, USA
| |
Collapse
|
75
|
Vennam S, Georgoulas S, Khawaja A, Chua S, Strouthidis NG, Foster PJ. Heavy metal toxicity and the aetiology of glaucoma. Eye (Lond) 2020; 34:129-137. [PMID: 31745328 PMCID: PMC7002597 DOI: 10.1038/s41433-019-0672-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Accepted: 10/06/2019] [Indexed: 11/09/2022] Open
Abstract
Despite recent advances, our understanding of the aetiological mechanisms underlying glaucoma remains incomplete. Heavy metals toxicity has been linked to the development of neurodegenerative diseases and various ocular pathologies. Given the similarities in pathophysiology between glaucoma and some neurodegenerative disorders, it is plausible that heavy metal toxicity may play a role in the development of glaucoma. Heavy metal exposure may be occupational, or through water or dietary contamination. In this report, we review mechanisms for systemic and neurotoxicity for arsenic, cadmium, chromium, cobalt, lead, mercury, and manganese, and weigh the evidence for an association between glaucoma and the accumulation of heavy metals either in ocular tissues or in the central nervous system.
Collapse
Affiliation(s)
- Sarath Vennam
- UCL Institute of Ophthalmology, 11-43 Bath Street, London, EC1V 9E, UK
| | - Stelios Georgoulas
- UCL Institute of Ophthalmology, 11-43 Bath Street, London, EC1V 9E, UK
- Glaucoma Service, Moorfields Eye Hospital, City Road, London, EC1V 2PD, UK
| | - Anthony Khawaja
- UCL Institute of Ophthalmology, 11-43 Bath Street, London, EC1V 9E, UK
- Glaucoma Service, Moorfields Eye Hospital, City Road, London, EC1V 2PD, UK
| | - Sharon Chua
- UCL Institute of Ophthalmology, 11-43 Bath Street, London, EC1V 9E, UK
| | - Nicholas G Strouthidis
- UCL Institute of Ophthalmology, 11-43 Bath Street, London, EC1V 9E, UK
- Glaucoma Service, Moorfields Eye Hospital, City Road, London, EC1V 2PD, UK
| | - Paul J Foster
- UCL Institute of Ophthalmology, 11-43 Bath Street, London, EC1V 9E, UK.
- Glaucoma Service, Moorfields Eye Hospital, City Road, London, EC1V 2PD, UK.
| |
Collapse
|
76
|
Goodman SB, Gallo J, Gibon E, Takagi M. Diagnosis and management of implant debris-associated inflammation. Expert Rev Med Devices 2020; 17:41-56. [PMID: 31810395 PMCID: PMC7254884 DOI: 10.1080/17434440.2020.1702024] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2019] [Accepted: 12/04/2019] [Indexed: 02/07/2023]
Abstract
Introduction: Total joint replacement is one of the most common, safe, and efficacious operations in all of surgery. However, one major long-standing and unresolved issue is the adverse biological reaction to byproducts of wear from the bearing surfaces and modular articulations. These inflammatory reactions are mediated by the innate and adaptive immune systems.Areas covered: We review the etiology and pathophysiology of implant debris-associated inflammation, the clinical presentation and detailed work-up of these cases, and the principles and outcomes of non-operative and operative management. Furthermore, we suggest future strategies for prevention and novel treatments of implant-related adverse biological reactions.Expert opinion: The generation of byproducts from joint replacements is inevitable, due to repetitive loading of the implants. A clear understanding of the relevant biological principles, clinical presentations, investigative measures and treatments for implant-associated inflammatory reactions and periprosthetic osteolysis will help identify and treat patients with this issue earlier and more effectively. Although progressive implant-associated osteolysis is currently a condition that is treated surgically, with further research, it is hoped that non-operative biological interventions could prolong the lifetime of joint replacements that are otherwise functional and still salvageable.
Collapse
Affiliation(s)
- Stuart B. Goodman
- Department of Orthopaedic Surgery, Stanford University, Redwood City, CA, USA
- Department of Bioengineering, Stanford University, Stanford, CA, USA
| | - Jiri Gallo
- Department of Orthopaedics, Palacký University Olomouc, Olomouc, Czech Republic
| | - Emmanuel Gibon
- Department of Orthopaedic Surgery, University of Florida, Gainesville, FL, USA
| | - Michiaki Takagi
- Department of Orthopaedic Surgery, Yamagata University, Yamagata, Japan
| |
Collapse
|
77
|
Kuder M, Gelman A, Zenilman JM. Prevalence of Implanted Medical Devices in Medicine Inpatients. J Patient Saf 2019; 14:153-156. [PMID: 26067750 DOI: 10.1097/pts.0000000000000187] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Implanted medical devices (IMDs) are extremely common, yet they are not systematically documented on hospital admission. Through structured patient interviews, we determined the prevalence of IMDs in hospital inpatients. Using medical record review, we evaluated the sensitivity of the medical record reporting of IMDs on an academic medical inpatient service. Fifty-eight percent of 191 interviewees reported 1 or more IMDs. Participants who reported greater than 1 IMD were older and had more frequent hospitalizations. The most common devices reported were surgical mesh, screws, plates, or wires (n = 47); intravascular stents (n = 25); and prosthetic joint replacements (n = 17). Forty-six patients (24%) reported greater than 1 IMD that had not been recorded in their admission history and physical examination. The prevalence of IMDs in hospitalized patients is high and underestimated in the medical record and may have significant implications for patient care.
Collapse
Affiliation(s)
| | - Amanda Gelman
- University of Colorado School of Medicine, Aurora, CO
| | - Jonathan M Zenilman
- Division of Infectious Diseases, Johns Hopkins University School of Medicine, Baltimore, MD
| |
Collapse
|
78
|
Reich MS, Javidan P, Garg VK, Copp SN. Chronic Systemic Metal Ion Toxicity from Wear on a Revised Cobalt-chromium Trunnion. J Orthop Case Rep 2019; 9:48-51. [PMID: 31534934 PMCID: PMC6727449 DOI: 10.13107/jocr.2250-0685.1366] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Introduction: Metal toxicity secondary to corrosion and wear has been reviewed in the arthroplasty literature with evidence supporting dermatologic, neurologic, and cardiac involvement. This is the first report of a novel case with the occurrence of systemic pathology with only mildly elevated serum cobalt (Co) and chromium (Cr) levels due to trunnion wear in a metal-on-polyethylene articulation. Case Report: A 45-year-old female who had undergone a revision total hip arthroplasty developed concerning dermatologic, neurologic, and cardiac symptoms. Symptoms were initially attributed to an unknown autoimmune etiology. She had mildly elevated cobalt and chromium levels and subsequently underwent a second revision, this time with complete exchange of the cobalt/chromium components. By her 2-month follow-up, she reported partial resolution of symptoms. She continues to improve more than a year postoperatively. Conclusion: Consideration should be given to metal ion toxicity due to trunnion wear in patients with cobalt/chromium femoral components, even with relatively low ion levels.
Collapse
Affiliation(s)
- Michael S Reich
- Department of Orthopaedics, Texas Tech University Health Sciences Center El Paso, 4801 Alberta Ave, El Paso, TX 79905, USA.,Department of Orthopaedic Surgery, Scripps Clinic, 10666 North Torrey Pines Road, MS116, La Jolla, CA 92037, USA
| | - Pooya Javidan
- Department of Orthopaedics, Southern California Permanente Medical Group, 250 Travelodge Dr, El Cajon, CA 92020, USA.,Department of Orthopaedic Surgery, Scripps Clinic, 10666 North Torrey Pines Road, MS116, La Jolla, CA 92037, USA
| | - Vikram K Garg
- Department of Rheumatology and Internal Medicine, Scripps Clinic, 310 Santa Fe Drive, Encinitas, CA 92024, USA
| | - Steven N Copp
- Department of Orthopaedic Surgery, Scripps Clinic, 10666 North Torrey Pines Road, MS116, La Jolla, CA 92037, USA
| |
Collapse
|
79
|
Ort MJ, Geissler S, Rakow A, Schoon J. The Allergic Bone Marrow? The Immuno-Capacity of the Human Bone Marrow in Context of Metal-Associated Hypersensitivity Reactions. Front Immunol 2019; 10:2232. [PMID: 31620137 PMCID: PMC6759684 DOI: 10.3389/fimmu.2019.02232] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2019] [Accepted: 09/03/2019] [Indexed: 12/11/2022] Open
Abstract
Arthroplasty ranks among the greatest achievements of surgical medicine, with total hip replacement termed “the operation of the century.” Despite its wide success, arthroplasty bears risks, such as local reactions to implant derived wear and corrosion products. Prevalence of allergies across Western society increases and along the number of reported hypersensitivity reactions to orthopedic implant materials. In this context the main focus is on delayed hypersensitivity (DTH). This mechanism is mainly attributed to T cells and an overreaction of the adaptive immune system. Arthroplasty implant materials are in direct contact with bone marrow (BM), which is discussed as a secondary lymphoid organ. However, the mechanisms of sensitization toward implant wear remain elusive. Nickel and cobalt ions can form haptens with native peptides to activate immune cell receptors and are therefore common T helper allergens in cutaneous DTH. The rising prevalence of metal-related allergy in the general population and evidence for the immune-modulating function of BM allow for the assumption hypersensitivity reactions could occur in peri-implant BM. There is evidence that pro-inflammatory factors released during DTH reactions enhance osteoclast activity and inhibit osteoblast function, an imbalance characteristic for osteolysis. Even though some mechanisms are understood, hypersensitivity has remained a diagnosis of exclusion. This review aims to summarize current views on the pathomechanism of DTH in arthroplasty with emphasis on BM and discusses recent advances and future directions for basic research and clinical diagnostics.
Collapse
Affiliation(s)
- Melanie J Ort
- Julius Wolff Institute, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany.,Berlin Institute of Health Center for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Berlin, Germany.,Berlin-Brandenburg School for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Sven Geissler
- Julius Wolff Institute, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany.,Berlin Institute of Health Center for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Berlin, Germany.,Berlin-Brandenburg School for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Anastasia Rakow
- Berlin Institute of Health Center for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Berlin, Germany.,Center for Musculoskeletal Surgery, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Janosch Schoon
- Julius Wolff Institute, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany.,Berlin Institute of Health Center for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Berlin, Germany.,Berlin-Brandenburg School for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| |
Collapse
|
80
|
Kaur M, Singh K. Review on titanium and titanium based alloys as biomaterials for orthopaedic applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 102:844-862. [PMID: 31147056 DOI: 10.1016/j.msec.2019.04.064] [Citation(s) in RCA: 398] [Impact Index Per Article: 79.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2018] [Revised: 02/20/2019] [Accepted: 04/20/2019] [Indexed: 02/07/2023]
Abstract
Variety of implant materials have been employed in various disciplines of medical science depending on the requirement of a particular application. Metals, alloys, ceramics, and polymers are the commonly used biomaterials. The main focus of this study is to review the various structural and microstructural properties of titanium and titanium based alloys used as orthopaedic implants. Orthopaedic implants need to possess certain important qualities to ensure their safe and effective use. These properties like the biocompatibility, relevant mechanical properties, high corrosion and wear resistance and osseointegration are summarized in this review. Various attempts to improve upon these properties like different processing routes, surface modifications have also been inculcated in the paper to provide an insight into the extent of research and effort that has been put into developing a highly superior titanium orthopaedic implant.
Collapse
Affiliation(s)
- Manmeet Kaur
- School of Physics and Materials Science, Thapar Institute of Engineering and Technology, Patiala, Punjab 147004, India
| | - K Singh
- School of Physics and Materials Science, Thapar Institute of Engineering and Technology, Patiala, Punjab 147004, India.
| |
Collapse
|
81
|
Sharma S, Sharma RK, Gaur K, Cátala Torres JF, Loza-Rosas SA, Torres A, Saxena M, Julin M, Tinoco AD. Fueling a Hot Debate on the Application of TiO 2 Nanoparticles in Sunscreen. MATERIALS (BASEL, SWITZERLAND) 2019; 12:E2317. [PMID: 31330764 PMCID: PMC6678326 DOI: 10.3390/ma12142317] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2019] [Revised: 07/17/2019] [Accepted: 07/17/2019] [Indexed: 12/20/2022]
Abstract
Titanium is one of the most abundant elements in the earth's crust and while there are many examples of its bioactive properties and use by living organisms, there are few studies that have probed its biochemical reactivity in physiological environments. In the cosmetic industry, TiO2 nanoparticles are widely used. They are often incorporated in sunscreens as inorganic physical sun blockers, taking advantage of their semiconducting property, which facilitates absorbing ultraviolet (UV) radiation. Sunscreens are formulated to protect human skin from the redox activity of the TiO2 nanoparticles (NPs) and are mass-marketed as safe for people and the environment. By closely examining the biological use of TiO2 and the influence of biomolecules on its stability and solubility, we reassess the reactivity of the material in the presence and absence of UV energy. We also consider the alarming impact that TiO2 NP seepage into bodies of water can cause to the environment and aquatic life, and the effect that it can have on human skin and health, in general, especially if it penetrates into the human body and the bloodstream.
Collapse
Affiliation(s)
- Shweta Sharma
- Department of Environmental Sciences, University of Puerto Rico Río Piedras, 17 AVE Universidad STE 1701, San Juan, PR 00925-2537, USA
| | - Rohit K Sharma
- Department of Chemistry, University of Puerto Rico Río Piedras, 17 AVE Universidad STE 1701, San Juan, PR 00925-2537, USA
| | - Kavita Gaur
- Department of Chemistry, University of Puerto Rico Río Piedras, 17 AVE Universidad STE 1701, San Juan, PR 00925-2537, USA
| | - José F Cátala Torres
- Department of Chemistry, University of Puerto Rico Río Piedras, 17 AVE Universidad STE 1701, San Juan, PR 00925-2537, USA
| | - Sergio A Loza-Rosas
- Department of Chemistry, University of Puerto Rico Río Piedras, 17 AVE Universidad STE 1701, San Juan, PR 00925-2537, USA
| | - Anamaris Torres
- Biochemistry & Pharmacology Department, San Juan Bautista School of Medicine, Caguas, PR 00726, USA
| | - Manoj Saxena
- Department of Chemistry, University of Puerto Rico Río Piedras, 17 AVE Universidad STE 1701, San Juan, PR 00925-2537, USA
| | - Mara Julin
- Department of Chemistry, Syracuse University, Syracuse, NY 13244, USA
| | - Arthur D Tinoco
- Department of Chemistry, University of Puerto Rico Río Piedras, 17 AVE Universidad STE 1701, San Juan, PR 00925-2537, USA.
| |
Collapse
|
82
|
Harrison-Brown M, Scholes C, Field C, McQuilty R, Farah SB, Nizam I, Kerr D, Kohan L. Limited penetration of cobalt and chromium ions into the cerebrospinal fluid following metal on metal arthroplasty: a cross-sectional analysis. Clin Toxicol (Phila) 2019; 58:233-240. [PMID: 31298064 DOI: 10.1080/15563650.2019.1636993] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Background: The purpose of this study was to determine the concentration of cobalt (Co) and chromium (Cr) ions in synovial fluid, blood plasma and cerebrospinal fluid (CSF) of patients with metal-on-metal (MoM) implants, and to assess the relationship between implant history and patient characteristics with ion concentrations in CSF.Methods: An observational, non-randomised cross-sectional study was conducted with patients presenting to a single surgeon for treatment of degenerative conditions of the hip and knee. Blood and fluid samples were collected intraoperatively and analysed for proteins and trace elements.Results: Overall, the presence of an implant was associated with significantly higher Co and Cr concentrations in plasma (controls 5-115 nmol/L Co, 5-232 nmol/L Cr; well-functioning implant recipients 5-469 nmol/L Co, 5-608 nmol/L Cr; hip revisions 6-546 nmol/L Co, 5-573 nmol/L Cr), and for Cr concentrations in CSF (controls 5-24 nmol/L; well-functioning implant recipients 6-36 nmol/L, hip revisions 7-32 nmol/L). In absolute terms, <1% of the levels observed in the joint fluid and <15% of plasma metals appeared in the CSF. Multivariable regression models suggested different transfer mechanisms of Co and Cr to the CSF, with the presence of an implant not associated with ion levels.Conclusion: The presence of MoM implants is associated with significantly higher plasma levels of Co and Cr but not CSF levels, and the CSF/plasma ratio appears to be influenced by the plasma concentration in a nonlinear fashion. Co and Cr may be transferred to the CSF by different mechanisms, and their concentrations appears dependent on other factors yet to be identified. Although higher levels of plasma ions are associated with above average CSF metal concentrations, the thresholds for neurotoxicity remain unclear and require further study.
Collapse
Affiliation(s)
| | | | | | - Robert McQuilty
- Department of Chemical Pathology, Royal Prince Alfred Hospital, Sydney, Australia
| | - Sami B Farah
- Joint Orthopaedic Centre, Sydney, Australia.,A. M. Orthopaedics, Sydney, Australia
| | | | | | | |
Collapse
|
83
|
Park CW, Kim JH, Lim SJ, Moon YW, Park YS. A Minimum of 15-Year Results of Cementless Total Hip Arthroplasty Using a 28-mm Metal-On-Metal Articulation. J Arthroplasty 2019; 34:1387-1394. [PMID: 30930158 DOI: 10.1016/j.arth.2019.03.010] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 02/18/2019] [Accepted: 03/04/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND We previously reported unexpected early failures of total hip arthroplasty (THA) utilizing a 28-mm Ultima metal-on-metal (MoM) articulation. However, long-term results of small-diameter MoM THAs still remain unclear. The purpose of this study was to evaluate the clinical and radiographic outcomes of the previously reported cohort at a minimum follow-up of 15 years. METHODS The original cohort consisted of 171 primary THAs (167 patients) using a 28-mm MoM articulation performed between April 2000 and March 2002. Of these, 130 hips (126 patients) were reviewed at an average follow-up of 17.1 (range, 15-18) years. Clinical score, complications, presence of osteolytic lesion, serum metal ion concentrations, and implant survivorships were evaluated. RESULTS The mean Harris Hip Score improved from 44.9 points preoperatively to 90.5 points at the latest follow-up. During the entire period since the original surgery, a total of 5 revisions (3.8%) were associated with adverse reaction to metal debris (ARMD). The last revision surgery for symptomatic ARMD was performed at 6 years postoperatively. The implant survivorships with an end point of revision for aseptic failure and for any reason were 95.4% and 93.8%, respectively. Radiographic osteolytic lesions were detected in 27 hips (20.8%). The average serum metal concentration was 2.50 (range, 0.12-9.86) μg/L for cobalt and 2.81 (range, 0.82-12.3) μg/L for chromium. CONCLUSIONS THA using a 28-mm MoM articulation showed favorable long-term outcomes with a relatively high revision-free survival rate. There was no significant symptomatic ARMD after the last acetabular revision performed at 6 years postoperatively.
Collapse
Affiliation(s)
- Chan-Woo Park
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Joo-Hwan Kim
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Seung-Jae Lim
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Young-Wan Moon
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Youn-Soo Park
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| |
Collapse
|
84
|
Olmedo-Garcia NI, Zagra L. High risk of complications using metal heads after ceramic fracture in total hip arthroplasty. Hip Int 2019; 29:373-378. [PMID: 30501527 DOI: 10.1177/1120700018813978] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND There is some uncertainty about the bearing to be used to substitute a broken ceramic. Using metal components (head or liner) may lead to catastrophic wear of the metal. AIM The purpose of this article is to describe the long-term follow-up result of ceramic fracture replaced with metal-on-polyethylene (MoP). METHODS We report 3 cases of ceramic head fracture after ceramic-on-ceramic (CoC) total hip arthroplasty (THA) in which the broken ceramic was replaced with MoP. RESULTS All cases developed severe complications due to gross wear of the metal head: one developed a pseudotumour after a few months while the other 2 had significant local metallosis and toxic blood metal levels. CONCLUSIONS When there is a fracture of a ceramic component, we advise caution with the use of metal heads, as small ceramic fragments can cause 3rd-body wear with massive metal debris and severe local and general complications.
Collapse
Affiliation(s)
| | - Luigi Zagra
- 2 IRCCS Galeazzi Othopaedic Institute, Milan, Italy
| |
Collapse
|
85
|
Chalmers BP, Mangold DG, Hanssen AD, Pagnano MW, Trousdale RT, Abdel MP. Uniformly low serum cobalt levels after modular dual-mobility total hip arthroplasties with ceramic heads: a prospective study in high-risk patients. Bone Joint J 2019; 101-B:57-61. [PMID: 31146553 DOI: 10.1302/0301-620x.101b6.bjj-2018-1403.r1] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Modular dual-mobility constructs reduce the risk of dislocation after revision total hip arthroplasty (THA). However, questions about metal ions from the cobalt-chromium (CoCr) liner persist, and are particularly germane to patients being revised for adverse local tissue reactions (ALTR) to metal. We determined the early- to mid-term serum Co and Cr levels after modular dual-mobility components were used in revision and complex primary THAs, and specifically included patients revised for ALTR. PATIENTS AND METHODS Serum Co and Cr levels were measured prospectively in 24 patients with a modular dual-mobility construct and a ceramic femoral head. Patients with CoCr heads or contralateral THAs with CoCr heads were excluded. The mean age was 63 years (35 to 83), with 13 patients (54%) being female. The mean follow-up was four years (2 to 7). Indications for modular dual-mobility were prosthetic joint infection treated with two-stage exchange and subsequent reimplantation (n = 8), ALTR revision (n = 7), complex primary THA (n = 7), recurrent instability (n = 1), and periprosthetic femoral fracture (n = 1). The mean preoperative Co and Cr in patients revised for an ALTR were 29.7 μg/l (2 to 146) and 21.5 μg/l (1 to 113), respectively. RESULTS Mean Co and Cr levels were 0.30 μg/l and 0.76 μg/l, respectively, at the most recent follow-up. No patient had a Co level ≥ 1 μg/l. Only one patient had a Cr level ≥ 1 μg/l. That patient's Cr level was 12 μg/l at 57 months after revision THA for ALTR (and decreased ten-fold from a preoperative Cr of 113 μg/l). CONCLUSION At a mean of four years, no patient with a modular dual-mobility construct and ceramic femoral head had elevated Co levels, including seven patients revised specifically for ALTR. While further studies are required, we support the selective use of a modular dual-mobility construct in revision and complex primary THAs for patients at high risk for instability. Cite this article: Bone Joint J 2019;101-B(6 Supple B):57-61.
Collapse
Affiliation(s)
- B P Chalmers
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - D G Mangold
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - A D Hanssen
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - M W Pagnano
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - R T Trousdale
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - M P Abdel
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA
| |
Collapse
|
86
|
Manisty C, Skinner J, Moon JC. Metal-on-metal hips and heart failure - Can we relax? Int J Cardiol 2019; 284:65-66. [PMID: 30224256 DOI: 10.1016/j.ijcard.2018.09.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Revised: 08/22/2018] [Accepted: 09/03/2018] [Indexed: 11/29/2022]
Affiliation(s)
- Charlotte Manisty
- Institute of Cardiovascular Sciences, University College London, UK; Department of Cardiac Imaging, Barts Heart Centre, London, UK.
| | - John Skinner
- Department of Orthopaedics, Royal National Orthopaedic Hospital, Stanmore, UK
| | - James C Moon
- Institute of Cardiovascular Sciences, University College London, UK; Department of Cardiac Imaging, Barts Heart Centre, London, UK
| |
Collapse
|
87
|
Silva ADM, Figueiredo VMGD, Prado RFD, Santanta-Melo GDF, Ankha MDVEA, de Vasconcellos LMR, da Silva Sobrinho AS, Borges ALS, Nogueira Junior L. Diamond-like carbon films over reconstructive TMJ prosthetic materials: Effects in the cytotoxicity, chemical and mechanical properties. J Oral Biol Craniofac Res 2019; 9:201-207. [PMID: 31110936 DOI: 10.1016/j.jobcr.2019.04.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2019] [Accepted: 04/15/2019] [Indexed: 10/27/2022] Open
Abstract
Increasingly more young patients have been submitted to reconstruction of the Temporomandibular Joint (TMJ), so, the prostheses must to present more functional longevity. Objective To evaluate the effect of diamond-like carbon film (DLC) over titanium alloy (Ti6Al4V) and polyethylene (UHWPE) samples, their mechanical and chemical properties and cellular cytotoxicity. Methods Titanium and UHWPE specimens, with 2.5 cm in diameter and 2 mm thickness were coated through plasma enhanced chemical vapor deposition (PECVD) with DLC or DLC doped with silver (DLC-Ag). Scanning electron microscopy (SEM) morphological analysis, Energy-dispersive spectroscopy (EDS) chemical analysis, scratching test, mechanical fatigue test, surface roughness analysis, and cellular cytotoxicity were performed. Data were statistically analyzed using one-way ANOVA (p < 0.05) or two-way ANOVA and multiple comparison Tukey test. Results In the SEM analysis, morphological differences were observed on substrates after DLC deposition. The film chemically modified the substrate surfaces, according to the EDS analysis. The initial critical load failure occurred at 6.1 N for DLC and 9.7 N for the DLC-Ag film. The DLC film deposition over the polyethylene promoted a decrease in the polymer's damaged area after mechanical fatigue cycling. The cytotoxicity analysis demonstrated less biocompatibility in experimental groups, when compared to control, however, increased biocompatibility was observed, at 10 days, in all groups. Conclusion The diamond-like carbon coating enhanced the chemical and mechanical properties from substrates, however modified biological interaction course of the titanium alloy (Ti6Al4V) and polyethylene (UHWPE) samples. Parameters for film deposition remain to be improved in order to obtain best biocompatibility.
Collapse
Affiliation(s)
- Alecsandro de Moura Silva
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology of São José dos Campos, São Paulo State University (UNESP), Sao Jose dos Campos, Brazil
| | - Viviane Maria Gonçalves de Figueiredo
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology of São José dos Campos, São Paulo State University (UNESP), Sao Jose dos Campos, Brazil
| | - Renata Falchete do Prado
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology of São José dos Campos, São Paulo State University (UNESP), Sao Jose dos Campos, Brazil
| | | | | | | | | | - Alexandre Luiz Souto Borges
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology of São José dos Campos, São Paulo State University (UNESP), Sao Jose dos Campos, Brazil
| | - Lafayette Nogueira Junior
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology of São José dos Campos, São Paulo State University (UNESP), Sao Jose dos Campos, Brazil
| |
Collapse
|
88
|
Erickson J, Liu JX, Glickel SZ. Failure of Adjustably Aligned Modular Radial Head Arthroplasty With Head-Neck Dissociation and Metallosis. J Hand Surg Am 2019; 44:253.e1-253.e5. [PMID: 30292711 DOI: 10.1016/j.jhsa.2018.07.016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2017] [Revised: 06/08/2018] [Accepted: 07/25/2018] [Indexed: 02/02/2023]
Abstract
Radial head arthroplasty was introduced in 1941 and the literature supports satisfactory overall midterm patient outcomes and acceptable complication profiles with several models. There are several previously described mechanisms by which radial head complications typically occur. We present the case of a rarely described mechanism of radial head implant failure: elbow synovitis and pain from partial dissociation and metallosis in an adjustably aligned, modular, monopolar, mixed metal, press-fit radial head arthroplasty.
Collapse
Affiliation(s)
- John Erickson
- Department of Orthopaedic Surgery, Division of Hand Surgery, NYU Langone Medical Center Hospital for Joint Diseases, New York, NY
| | - James X Liu
- Department of Orthopaedic Surgery, Division of Hand Surgery, NYU Langone Medical Center Hospital for Joint Diseases, New York, NY.
| | - Steven Z Glickel
- Department of Orthopaedic Surgery, Division of Hand Surgery, NYU Langone Medical Center Hospital for Joint Diseases, New York, NY
| |
Collapse
|
89
|
Chromium-Cobalt Intoxication with Intense Systemic Complications following Total Hip Revision after Per-Operative Ceramic Fracture. Case Rep Orthop 2019; 2019:4209796. [PMID: 30809405 PMCID: PMC6369479 DOI: 10.1155/2019/4209796] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Accepted: 12/23/2018] [Indexed: 11/18/2022] Open
Abstract
Introduction Heavy metal intoxication after arthroplasty is extremely rare but could be lethal. Case Report. We report the case of a 69-year-old woman, who presented intense systemic symptoms of chromium-cobalt intoxication after revision of per-operative fractured ceramic components with metal-on-polyethylene. Systemic toxicity occurred a year after surgery and expressed brutally with mostly central neurological symptoms. Chelation associated with revision surgery allowed rapid regression of all symptoms. Conclusion Revision of fractured ceramic, even per-operatively, should not be done with metal-on-polyethylene components, in order to avoid potentially lethal metal intoxication.
Collapse
|
90
|
Kim H, Seo Y, Youn Y, Lee H, Yang M, Kim C. Determination of Fe2+
and Co2+
by a Multiple-Target Colorimetric Chemosensor with Low Detection Limit in Aqueous Solution. ChemistrySelect 2019. [DOI: 10.1002/slct.201803415] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- Hyunjun Kim
- Nowon Institute of Education for The Gifted at Seoultech; Seoul National Univ. of Sci. and Tech.; Seoul 01810 South Korea
| | - Yujin Seo
- Nowon Institute of Education for The Gifted at Seoultech; Seoul National Univ. of Sci. and Tech.; Seoul 01810 South Korea
| | - Yeojin Youn
- Nowon Institute of Education for The Gifted at Seoultech; Seoul National Univ. of Sci. and Tech.; Seoul 01810 South Korea
| | - Hakyung Lee
- Nowon Institute of Education for The Gifted at Seoultech; Seoul National Univ. of Sci. and Tech.; Seoul 01810 South Korea
| | - Minuk Yang
- Department of Fine Chem.; Seoul National Univ. of Sci. and Tech.; Seoul 01810 South Korea
| | - Cheal Kim
- Nowon Institute of Education for The Gifted at Seoultech; Seoul National Univ. of Sci. and Tech.; Seoul 01810 South Korea
- Department of Fine Chem.; Seoul National Univ. of Sci. and Tech.; Seoul 01810 South Korea
| |
Collapse
|
91
|
Michalek J, Vrablikova A, Darinskas A, Lukac L, Prucha J, Skopalik J, Travnik J, Cibulka M, Dudasova Z. Stromal vascular fraction cell therapy for osteoarthritis in elderly: Multicenter case-control study. J Clin Orthop Trauma 2019; 10:76-80. [PMID: 30705536 PMCID: PMC6349628 DOI: 10.1016/j.jcot.2018.11.010] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2018] [Revised: 11/21/2018] [Accepted: 11/22/2018] [Indexed: 12/13/2022] Open
Affiliation(s)
- Jaroslav Michalek
- Internal Consortium for Cell Therapy and Immunotherapy, Brno, Czech Republic
- Cellthera Clinic, Brno, Czech Republic
- Department of Pediatrics, University Hospital Brno, Brno, Czech Republic
| | | | - Adas Darinskas
- Internal Consortium for Cell Therapy and Immunotherapy, Brno, Czech Republic
- Department of Pharmacology, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | | | - Jaroslav Prucha
- Department of Health Care Disciplines and Population Protection, Faculty of Biomedical Engineering, Czech Technical University in Prague, Prague, Czech Republic
| | - Josef Skopalik
- Cellthera Clinic, Brno, Czech Republic
- Department of Human Pharmacology and Toxicology, Faculty of Pharmacy, University of Veterinary and Pharmaceutical Sciences, Brno, Czech Republic
| | - Jan Travnik
- Cellthera Clinic, Brno, Czech Republic
- Department of Orthopedics, Traumatology Hospital, Brno, Czech Republic
| | | | - Zuzana Dudasova
- Internal Consortium for Cell Therapy and Immunotherapy, Brno, Czech Republic
- Cellthera Clinic, Brno, Czech Republic
| |
Collapse
|
92
|
Manifestations systémiques compliquant une intoxication par les métaux liée à la dégradation d’une prothèse de hanche, étude d’un cas. Rev Med Interne 2018. [DOI: 10.1016/j.revmed.2018.10.190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
93
|
Hall DJ, Pourzal R, Jacobs JJ, Urban RM. Metal wear particles in hematopoietic marrow of the axial skeleton in patients with prior revision for mechanical failure of a hip or knee arthroplasty. J Biomed Mater Res B Appl Biomater 2018; 107:1930-1936. [DOI: 10.1002/jbm.b.34285] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Revised: 10/30/2018] [Accepted: 11/04/2018] [Indexed: 12/27/2022]
Affiliation(s)
- Deborah J. Hall
- Department of Orthopedic SurgeryRush University Medical Center Chicago Illinois
| | - Robin Pourzal
- Department of Orthopedic SurgeryRush University Medical Center Chicago Illinois
| | - Joshua J. Jacobs
- Department of Orthopedic SurgeryRush University Medical Center Chicago Illinois
| | - Robert M. Urban
- Department of Orthopedic SurgeryRush University Medical Center Chicago Illinois
| |
Collapse
|
94
|
D'Angelo F, Tanas D, Gallazzi E, Zagra L. Adverse reaction to metal debris after small-head diameter metal-on-metal total hip arthroplasty: an increasing concern. Hip Int 2018; 28:35-42. [PMID: 30755124 DOI: 10.1177/1120700018812993] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION: Failures due to adverse reaction to metal debris (ARMD) have become an area of common focus among surgeons performing hip replacements. Several authors have reported data on the prevalence of these masses, in both symptomatic and asymptomatic patients after either large-diameter head metal-on-metal (MoM) total hip arthroplasty (THA) or hip resurfacing arthroplasty, with a large variability of rate. To our knowledge, few data are reported on the association of this lesion with the use of small-head diameter MoM. METHODS: 15 hips that were revised for ARMD in small-head MoM THA were included in this study. We focused our attention on the difficulties of diagnosis and treatment and also on the histologic aspects of the harvested pathologic tissue. RESULTS: The histological examination of our cases showed a presence of lymphocytic infiltrate suggesting a delayed hypersensitivity reaction to the metal of type IV (ALVAL), but different from each other in term of the prevalence of the cellular component. Osteolysis and severe soft tissue damage were also observed. Revision resulted in remission of the lesion and successful implant. CONCLUSIONS: Our observation suggests that the evidence of ARMD should be considered even in case of small-head MoM arthroplasty and therefore these patients should be followed scrupulously with 2nd level diagnostic tools such as magnetic resonance imaging with metal artifact reduction sequence (MARS-MRI) and metal ion levels at least once. Further investigations are necessary to establish the real prevalence of this phenomenon in the whole population of small-head MoM THAs.
Collapse
Affiliation(s)
- Fabio D'Angelo
- 1 Department of Biotechnologies and Life Sciences, Division of Orthopaedics and Traumatology, University of Insubria, Italy
| | - Davide Tanas
- 1 Department of Biotechnologies and Life Sciences, Division of Orthopaedics and Traumatology, University of Insubria, Italy
| | - Enrico Gallazzi
- 2 Hip Department, I.R.C.C.S. Galeazzi Orthopaedic Institute, Milan, Italy
| | - Luigi Zagra
- 3 IRCCS Istituto Ortopedico Galeazzi, Hip Department, Milan, Italy
| |
Collapse
|
95
|
Lodge F, Khatun R, Lord R, John A, Fraser A, Yousef Z. Prevalence of subclinical cardiac abnormalities in patients with metal-on-metal hip replacements. Int J Cardiol 2018; 271:274-280. [DOI: 10.1016/j.ijcard.2018.05.047] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Revised: 05/08/2018] [Accepted: 05/15/2018] [Indexed: 10/16/2022]
|
96
|
Singh V, Skipor AK, Selim AA, Jacobs JJ. Chromium and Nickel Concentrations in Subjects with a Stainless Steel Metal-on-Metal Cervical Disc Arthroplasty: Results from a Prospective Longitudinal Study with 7 Years Follow-Up. Int J Spine Surg 2018; 12:460-468. [PMID: 30276106 DOI: 10.14444/5055] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Background Cervical disc arthroplasty (CDA) has emerged as an alternative to anterior cervical discectomy and fusion for degenerative cervical disc disease. The artificial discs provide intervertebral motion using multicomponent articulation and thus tend to generate particulate debris and soluble metal ions. Limited information is available on the long-term metal concentrations and associated systemic adverse events observed in metal-on-metal CDA. Serum chromium (Cr) and nickel (Ni) concentrations were assessed in patients implanted with ball-in-trough stainless steel-based cervical disc through 7 years. Methods A prospective, nonrandomized longitudinal study was conducted that included 25 patients following rigorous exclusion criteria that included no previous permanent metal implants and no professional exposure to metal particles. Blood serum Cr and Ni concentrations were assayed preoperatively and at 3, 6, 12, 24, 36, 60, and 84 months postoperatively using high-resolution inductively coupled plasma-mass spectrometry. Longitudinal statistical comparisons were made using the Friedman test with statistical significance at P < .05. Results Median serum concentrations determined preoperatively and at 3, 6, 12, 24, 36, 60, and 84 months postoperatively were 0.074, 0.106, 0.132, 0.170, 0.172, 0.274, 0.192, and 0.203 ng/mL for Cr and 0.085, 0.178, 0.222, 0.175, 0.205, 0.284, 0.181, and 0.194 ng/mL for Ni. The serum Cr concentrations were statistically higher for all postoperative time periods compared to preoperative concentration (Friedman P <.01), whereas serum Ni concentration was statistically higher at the 84-month postoperative time period than the preoperative concentration (Friedman P <.01) and then the concentration at 3, 12, 24, and 60 months postoperatively (Friedman P < .03). Conclusions The Cr concentrations detected at all postoperative times were statistically higher than preoperative concentrations, whereas Ni concentration was statistically higher than the preoperative concentration only at 84 months.
Collapse
Affiliation(s)
| | - Anastasia K Skipor
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| | | | - Joshua J Jacobs
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| |
Collapse
|
97
|
Sultan AA, Cantrell WA, Khlopas A, Berger RJ, Sodhi N, Molloy RM, Krebs VE, Mont MA. Evidence-Based Management of Trunnionosis in Metal-on-Polyethylene Total Hip Arthroplasty: A Systematic Review. J Arthroplasty 2018; 33:3343-3353. [PMID: 29929829 DOI: 10.1016/j.arth.2018.05.035] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Revised: 05/21/2018] [Accepted: 05/23/2018] [Indexed: 02/01/2023] Open
Abstract
Multiple recent reports have indicated a rising awareness of trunnionosis-related implant failures, accounting for up to 3% of all total hip arthroplasty revisions. Moreover, aseptic loosening and osteolysis from local release of metal debris can be the presenting manifestations, and thus the true incidence of trunnionosis is thought to be underreported. Furthermore, the relatively unclear and multifactorial pathogenesis and the widely variable clinical presentations pose a diagnostic challenge. A consensus regarding the ideal intervention and its timing is also lacking. Because of the relative paucity of reports regarding the diagnosis and management of trunnionosis, we conducted this evidence-based review to evaluate the (1) incidence, (2) pathogenesis, (3) diagnosis, and (4) treatment of trunnionosis in metal-on-polyethylene total hip arthroplasty. We then propose an algorithm for the diagnostic work-up and management of this condition.
Collapse
Affiliation(s)
- Assem A Sultan
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | | | - Anton Khlopas
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - Ryan J Berger
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - Nipun Sodhi
- Department of Orthopaedic Surgery, Lenox Hill Hospital, New York City, NY
| | - Robert M Molloy
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - Viktor E Krebs
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - Michael A Mont
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH; Department of Orthopaedic Surgery, Lenox Hill Hospital, New York City, NY
| |
Collapse
|
98
|
Pisanu F, Doria C, Andreozzi M, Bartoli M, Saderi L, Sotgiu G, Tranquilli Leali P. Pleomorphic clinical spectrum of metallosis in total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2018; 43:85-96. [PMID: 30269183 DOI: 10.1007/s00264-018-4176-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2018] [Accepted: 09/18/2018] [Indexed: 12/22/2022]
Abstract
PURPOSE To summarize the biological effects of metal debris from hip arthroplasties which characterize a polymorphic clinical spectrum of local and remote manifestation. METHODS Retrospective study. Patient, implant, and surgical characteristics were collected, including implant survival, clinical manifestations, cause of arthroplasty revision or implant failure, and peri- and intra-operative complications. The primary endpoint was implant survivorship. Hip revision arthroplasty was decided considering clinical signs and symptoms, abnormal imaging (XR, MR, TC, echotomography, scintigraphy), and blood metal ion level. An ad hoc electronic form was used to collect demographic, epidemiological, and clinical variables. In-between group comparisons of quantitative variables were performed with the Student t test and the Mann-Whitney for parametric and non-parametric variables, respectively. Logistic regression analyses were carried out to assess the relationship between clinical and radiographic characteristics and stem and cup revision. Radiographic measurements of implant positioning validity and reliability were assessed using Krippendorff's alpha reliability coefficient. The statistical software STATA version 15 (StatsCorp, TX) was used to perform statistical computations. RESULTS In this MoM THA series, the most incident cause of implant failure was ARMD in 11 out of 14 (78.6%) patients. All clinical failure manifestations, revision surgery highlights, and intra-operative findings are reported. CONCLUSIONS The local adverse reactions include lesions of different clinical relevance from small asymptomatic soft tissue lesions to dramatic osteolysis, necrosis, effusion, and growing masses which can cause secondary pathological effects. Symptoms of systemic toxicity are rarely described but may have been largely unreported in literature. Despite the extensive literature on the topic, the patient's management is still uncertain and challenging. Every metallic implant (e.g., screws, plates, spinal instrumentations) has a potential local or systemic adverse effect. Organizing a national registry of arthroplasty should be mandatory, in order to collect data about the patients, the surgery, the implanted device (with a careful post-marketing tracking), and the follow-up for all the procedures performed at a national level. The data collected in the registry will allow to analyze the implant survival and to better recognize the undesirable and sometimes unexpected effects of different biomaterials on the whole body.
Collapse
Affiliation(s)
| | - Carlo Doria
- Università degli Studi di Sassari, Sassari, Italy
| | | | | | - Laura Saderi
- Università degli Studi di Sassari, Sassari, Italy
| | | | | |
Collapse
|
99
|
Affiliation(s)
- Philippe Hantson
- Department of Intensive Care, Cliniques St-Luc, Université catholique de Louvain, Brussels, Belgium
- Louvain Centre for Toxicology and Applied Pharmacology, Cliniques St-Luc, Université catholique de Louvain, Brussels, Belgium
| |
Collapse
|
100
|
Stepien KM, Abidin Z, Lee G, Cullen R, Logan P, Pastores GM. Metallosis mimicking a metabolic disorder: a case report. Mol Genet Metab Rep 2018; 17:38-41. [PMID: 30271721 PMCID: PMC6159344 DOI: 10.1016/j.ymgmr.2018.09.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2018] [Revised: 09/17/2018] [Accepted: 09/17/2018] [Indexed: 11/05/2022] Open
Abstract
Metalic prosthesis or occupational exposure are potential sources of systemic cobalt and chromium ion toxicity. The resultant multisystemic clinical presentation can lead to unnecessary investigations before a final etiologic diagnosis is made; with an average delay of a year or more commonly noted. A 58-year old man presented with cardiomyopathy, pericardial effusion, polycytaemia, polyneuropathy, visual impairment, sudden hearing loss and hypothyroidism over a 2-year period post a metal-on-polyethylene hip replacement surgery. Biochemistry test results showed serum lactate of 3.8 mmol/L (0.5–2.2 mmol/L). Urine organic acid screen showed mild increases in excretion of tricarboxylic acid cycle intermediates and 2-ethylhydracryllate; suggestive of primary or secondary mitochondrial dysfunction. There were also slight increases in excretion of 4-hydroxyphenyllactate and 4-hydroxyphenylpyruvate suggestive of liver dysfunction. Acylcarnitine profile showed slight increase in hydroxybutyrylcarnitine and tetradeceneoylcarnitine that may reflect ketosis. In view of his clinical presentation and abnormal metabolic investigations, the initial working diagnosis was mitochondrial disease. Subsequently, patient presented with hip pain, and radiologic and imaging studies revealed high density collections lateral to the right proximal part of the femur, and medial to the right ilium with signal changes suggestive of metallic content. This prompted toxicology screen which revealed elevated plasma cobalt concentration (903.32 μg/L; reference range: 0.1–0.4) and chromium (71.32 μg/L; <0.5). Six months post right hip prosthesis removal the concentrations have declined and was 61.72 μg/L and chromium 23.97 μg/L. Patient felt some improvement symptomatically, without evident deterioration in his vision or hearing. This case emphasises careful consideration of past medical history, in patients presenting with multisystemic disease suggestive of mitochondrial dysfunction, and potential causality related to exposure to toxic agents. In retrospect, the absence of a family history could be viewed as a pertinent negative finding. Not uncommonly, specialist focus on their favored system and may not search for a unifying diagnosis. It is likely further delays in diagnosis would have occurred had the patient not developed hip pains, and ultimately referred to the orthopedic surgeons more familiar with similar cases.
Collapse
Affiliation(s)
- Karolina M Stepien
- Adult Inherited Metabolic Diseases Department, Salford Royal NHS Foundation Trust, Salford, United Kingdom
| | - Zaza Abidin
- National Centre for Inherited Metabolic Diseases, The Mater Misericordiae University Hospital, Dublin, Ireland
| | - Graham Lee
- Clinical Biochemistry and Diagnostic Endocrinology, The Mater Misericordiae University Hospital, Dublin, Ireland
| | - Rachel Cullen
- Clinical Biochemistry and Diagnostic Endocrinology, The Mater Misericordiae University Hospital, Dublin, Ireland
| | - Patricia Logan
- Ophthalmology Department, The Mater Misericordiae University Hospital, Dublin, Ireland
| | - Gregory M Pastores
- National Centre for Inherited Metabolic Diseases, The Mater Misericordiae University Hospital, Dublin, Ireland
| |
Collapse
|