51
|
Fisher DG, Price RJ. Recent Advances in the Use of Focused Ultrasound for Magnetic Resonance Image-Guided Therapeutic Nanoparticle Delivery to the Central Nervous System. Front Pharmacol 2019; 10:1348. [PMID: 31798453 PMCID: PMC6864822 DOI: 10.3389/fphar.2019.01348] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2019] [Accepted: 10/24/2019] [Indexed: 12/12/2022] Open
Abstract
Targeting systemically-administered drugs and genes to specific regions of the central nervous system (CNS) remains a challenge. With applications extending into numerous disorders and cancers, there is an obvious need for approaches that facilitate the delivery of therapeutics across the impervious blood-brain barrier (BBB). Focused ultrasound (FUS) is an emerging treatment method that leverages acoustic energy to oscillate simultaneously administered contrast agent microbubbles. This FUS-mediated technique temporarily disrupts the BBB, allowing ordinarily impenetrable agents to diffuse and/or convect into the CNS. Under magnetic resonance image guidance, FUS and microbubbles enable regional targeting-limiting the large, and potentially toxic, dosage that is often characteristic of systemically-administered therapies. Subsequent to delivery across the BBB, therapeutics face yet another challenge: penetrating the electrostatically-charged, mesh-like brain parenchyma. Non-bioadhesive, encapsulated nanoparticles can help overcome this additional barrier to promote widespread treatment in selected target areas. Furthermore, nanoparticles offer significant advantages over conventional systemically-administered therapeutics. Surface modifications of nanoparticles can be engineered to enhance targeted cellular uptake, and nanoparticle formulations can be tailored to control many pharmacokinetic properties such as rate of drug liberation, distribution, and excretion. For instance, nanoparticles loaded with gene plasmids foster relatively stable transfection, thus obviating the need for multiple, successive treatments. As the formulations and applications of these nanoparticles can vary greatly, this review article provides an overview of FUS coupled with polymeric or lipid-based nanoparticles currently utilized for drug delivery, diagnosis, and assessment of function in the CNS.
Collapse
Affiliation(s)
| | - Richard J. Price
- Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, United States
| |
Collapse
|
52
|
Price RJ, Fisher DG, Suk JS, Hanes J, Ko HS, Kordower JH. Parkinson's disease gene therapy: Will focused ultrasound and nanovectors be the next frontier? Mov Disord 2019; 34:1279-1282. [PMID: 30908781 PMCID: PMC6754296 DOI: 10.1002/mds.27675] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2018] [Revised: 03/07/2019] [Accepted: 03/08/2019] [Indexed: 12/27/2022] Open
Affiliation(s)
- Richard J. Price
- Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA
| | - Delaney G. Fisher
- Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA
| | - Jung Soo Suk
- Center for Nanomedicine at the Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Justin Hanes
- Center for Nanomedicine at the Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Han Seok Ko
- Department of Neurology, Neuroregeneration and Stem Cell Programs, Institute for Cell Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Jeffrey H. Kordower
- Department of Neurological Sciences, Rush University Medical Center, Chicago, Illinois, USA
| |
Collapse
|
53
|
Scanning ultrasound in the absence of blood-brain barrier opening is not sufficient to clear β-amyloid plaques in the APP23 mouse model of Alzheimer's disease. Brain Res Bull 2019; 153:8-14. [PMID: 31400496 DOI: 10.1016/j.brainresbull.2019.08.002] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Revised: 08/01/2019] [Accepted: 08/05/2019] [Indexed: 02/07/2023]
Abstract
A major challenge in treating brain diseases is presented by the blood-brain barrier (BBB) that constitutes an efficient barrier not only for toxins but also a wide range of therapeutic agents. In overcoming this impediment, ultrasound in combination with intravenously injected microbubbles has emerged as a powerful technology that allows for the selective brain uptake of blood-borne factors and therapeutic agents by transient opening of the blood-brain barrier. We have previously shown that ultrasound in combination with microbubbles, but in the absence of a therapeutic agent, can effectively clear protein aggregates such as the hallmark lesions of Alzheimer's disease, amyloid-β (Aβ) plaques and Tau-containing neurofibrillary tangles. We have also demonstrated that the associated memory and motor impairments can be ameliorated or even restored. These studies included a negative sham control that received microbubbles in the absence of ultrasound. However, considering that ultrasound on its own is a pressure wave which has bioeffects, the possibility remained that ultrasound, without microbubbles, would also clear amyloid. We addressed this by performing repeated ultrasound only treatments of one brain hemisphere of Aβ-depositing APP23 mice, using the contralateral hemisphere as the unsonicated control. This was followed by an extensive histological analysis of fibrillar and non-fibrillar amyloid. We found that ultrasound on its own was not sufficient to clear amyloid. This implies that although ultrasound on its own has neuromodulatory effects, exogenously supplied microbubbles are required for the clearance of Aβ deposits.
Collapse
|
54
|
Roovers S, Segers T, Lajoinie G, Deprez J, Versluis M, De Smedt SC, Lentacker I. The Role of Ultrasound-Driven Microbubble Dynamics in Drug Delivery: From Microbubble Fundamentals to Clinical Translation. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2019; 35:10173-10191. [PMID: 30653325 DOI: 10.1021/acs.langmuir.8b03779] [Citation(s) in RCA: 110] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
In the last couple of decades, ultrasound-driven microbubbles have proven excellent candidates for local drug delivery applications. Besides being useful drug carriers, microbubbles have demonstrated the ability to enhance cell and tissue permeability and, as a consequence, drug uptake herein. Notwithstanding the large amount of evidence for their therapeutic efficacy, open issues remain. Because of the vast number of ultrasound- and microbubble-related parameters that can be altered and the variability in different models, the translation from basic research to (pre)clinical studies has been hindered. This review aims at connecting the knowledge gained from fundamental microbubble studies to the therapeutic efficacy seen in in vitro and in vivo studies, with an emphasis on a better understanding of the response of a microbubble upon exposure to ultrasound and its interaction with cells and tissues. More specifically, we address the acoustic settings and microbubble-related parameters (i.e., bubble size and physicochemistry of the bubble shell) that play a key role in microbubble-cell interactions and in the associated therapeutic outcome. Additionally, new techniques that may provide additional control over the treatment, such as monodisperse microbubble formulations, tunable ultrasound scanners, and cavitation detection techniques, are discussed. An in-depth understanding of the aspects presented in this work could eventually lead the way to more efficient and tailored microbubble-assisted ultrasound therapy in the future.
Collapse
Affiliation(s)
- Silke Roovers
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicine, Faculty of Pharmaceutical Sciences , Ghent University , Ottergemsesteenweg 460 , Ghent , Belgium
| | - Tim Segers
- Physics of Fluids Group, MESA+ Institute for Nanotechnology and Technical Medical (TechMed) Center , University of Twente , P.O. Box 217, 7500 AE Enschede , The Netherlands
| | - Guillaume Lajoinie
- Physics of Fluids Group, MESA+ Institute for Nanotechnology and Technical Medical (TechMed) Center , University of Twente , P.O. Box 217, 7500 AE Enschede , The Netherlands
| | - Joke Deprez
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicine, Faculty of Pharmaceutical Sciences , Ghent University , Ottergemsesteenweg 460 , Ghent , Belgium
| | - Michel Versluis
- Physics of Fluids Group, MESA+ Institute for Nanotechnology and Technical Medical (TechMed) Center , University of Twente , P.O. Box 217, 7500 AE Enschede , The Netherlands
| | - Stefaan C De Smedt
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicine, Faculty of Pharmaceutical Sciences , Ghent University , Ottergemsesteenweg 460 , Ghent , Belgium
| | - Ine Lentacker
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicine, Faculty of Pharmaceutical Sciences , Ghent University , Ottergemsesteenweg 460 , Ghent , Belgium
| |
Collapse
|
55
|
Zhang S, Xu T, Cui Z, Shi W, Wu S, Zong Y, Niu G, He X, Wan M. Time and Frequency Characteristics of Cavitation Activity Enhanced by Flowing Phase-Shift Nanodroplets and Lipid-Shelled Microbubbles During Focused Ultrasound Exposures. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:2118-2132. [PMID: 31151732 DOI: 10.1016/j.ultrasmedbio.2019.04.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 04/02/2019] [Accepted: 04/25/2019] [Indexed: 06/09/2023]
Abstract
This study investigated and compared the time and frequency characteristics of cavitation activity between phase-shift nanodroplets (NDs) and lipid-shelled microbubbles (MBs) exposed to focused ultrasound (FUS) under physiologically relevant flow conditions. Root-mean-square (RMS) of broadband noise, spectrograms of the passive cavitation detection signals and inertial cavitation doses (ICDs) were calculated during FUS at varying mean flow velocities and two different peak-rarefactional pressures. At a lower pressure of 0.94 MPa, the mean values of the RMS amplitudes versus time for the NDs showed an upward trend but slowed down as the mean flow velocity increased. For flowing NDs, the rate of growth in RMS amplitudes within 2-5 MHz decreased more obviously than those within 5-8 MHz. At a higher pressure of 1.07 MPa, the increase in RMS amplitudes was accelerated as the mean flow velocity increased from 0 to 10 cm/s and slowed down as the mean flow velocity reached 15 cm/s. The general downward trends of RMS amplitudes for the MBs were retarded as the mean flow velocity increased at both acoustic pressures of 0.94 MPa and 1.07 MPa. At 0.94 MPa, the mean ICD value for the NDs decreased from 57 to 36 as the mean flow velocity increased from 0 to 20 cm/s. At 1.07 MPa, the mean ICD value initially increased from 45 to 57 as the mean flow velocity increased from 0 to 10 cm/s and subsequently decreased to 43 as the mean flow velocity reached 20 cm/s. For the MBs, the mean ICD value increased with increasing mean flow velocity at both acoustic pressures. These results could aid in future investigations of cavitation-enhanced FUS with the flowing phase-shift NDs and encapsulated, gas-filled MBs for various applications.
Collapse
Affiliation(s)
- Siyuan Zhang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Tianqi Xu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Zhiwei Cui
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Wen Shi
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Shan Wu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Yujin Zong
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Gang Niu
- Department of Radiology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Xijing He
- Department of Orthopedics, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, People's Republic of China
| | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China.
| |
Collapse
|
56
|
Hallam KA, Emelianov SY. Toward optimization of blood brain barrier opening induced by laser-activated perfluorocarbon nanodroplets. BIOMEDICAL OPTICS EXPRESS 2019; 10:3139-3151. [PMID: 31360596 PMCID: PMC6640833 DOI: 10.1364/boe.10.003139] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 05/30/2019] [Accepted: 05/30/2019] [Indexed: 05/09/2023]
Abstract
The blood brain barrier (BBB), a component of the brain's natural defense system, is often a roadblock for the monitoring and treatment of neurological disorders. Recently, we introduced a technique to open the blood brain barrier through the use of laser-activated perfluorohexane nanodroplets (PFHnDs), a phase-change nanoagent that undergoes repeated vaporization and recondensation when excited by a pulsed laser. Laser-activated PFHnDs were shown to enable noninvasive and localized opening of the BBB, allowing extravasation of various sized agents into the brain tissue. In this current work, the laser-activated PFHnD-induced BBB opening is further explored. In particular, laser fluence and the number of laser pulses used for the PFHnD-induced BBB opening are examined and evaluated both qualitatively and quantitatively to determine the effect of these parameters on BBB opening. The results of these studies show trends between increased laser fluence and an increased BBB opening as well as between an increased number of laser pulses and an increased BBB opening, however, with limitations on the extent of the BBB opening after a certain number of pulses. Overall, the results of these studies serve as a guideline to choosing suitable laser parameters for safe and effective BBB opening.
Collapse
Affiliation(s)
- Kristina A. Hallam
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, Atlanta, GA, USA
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Stanislav Y. Emelianov
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, Atlanta, GA, USA
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| |
Collapse
|
57
|
Nisbet RM, Götz J. Amyloid-β and Tau in Alzheimer's Disease: Novel Pathomechanisms and Non-Pharmacological Treatment Strategies. J Alzheimers Dis 2019; 64:S517-S527. [PMID: 29562514 DOI: 10.3233/jad-179907] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Accumulation of the peptide amyloid-β (Aβ) and the protein tau in Alzheimer's disease (AD) brains is a gradual process that involves the post-translational modification and assembly of monomeric forms into larger structures that eventually form fibrillar inclusions. This process is thought to both drive and initiate AD. However, why the axonally enriched tau in the course of AD accumulates in the somatodendritic domain is not fully understood. We discuss new data that provide a possible explanation that involves de novo protein synthesis, induced by Aβ and mediated through the kinase Fyn. We further discuss how in a pathological state, tau, being a scaffolding protein, impairs nuclear and mitochondrial functions and reduces action potential generation at the axon initial segment. Pathological tau can further be packaged into exosomes, released by one neuron and taken up by another, contributing to its pathogenicity. We also present our new work that suggests ultrasound as a new treatment modality to clear pathological Aβ and tau. We put this work into perspective, discussing current vaccination strategies and improved brain delivery methods involving antibody engineering and viral approaches. We propose that rather than reducing post-translational modifications of tau, its levels and de novo synthesis need to be reduced. We anticipate a surge in combinatorial strategies, simultaneously targeting multiple pathologies, and an improved drug delivery to the brain facilitated by emerging technologies such as ultrasound.
Collapse
Affiliation(s)
- Rebecca M Nisbet
- Clem Jones Centre for Ageing Dementia Research, Queensland Brain Institute, The University of Queensland, Brisbane (St Lucia Campus), QLD, Australia
| | - Jürgen Götz
- Clem Jones Centre for Ageing Dementia Research, Queensland Brain Institute, The University of Queensland, Brisbane (St Lucia Campus), QLD, Australia
| |
Collapse
|
58
|
Cheng M, Li F, Han T, Yu ACH, Qin P. Effects of ultrasound pulse parameters on cavitation properties of flowing microbubbles under physiologically relevant conditions. ULTRASONICS SONOCHEMISTRY 2019; 52:512-521. [PMID: 30642801 DOI: 10.1016/j.ultsonch.2018.12.031] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2018] [Revised: 12/03/2018] [Accepted: 12/20/2018] [Indexed: 06/09/2023]
Abstract
Acoustic cavitation from ultrasound-driven microbubbles can induce diverse bioeffects that are useful in clinical therapy. However, lack of control over the cavitation activity of flowing microbubbles results in unwanted treatment regions in the targeted tissue, which influences the therapeutic efficacy and bio-safety. The aim of this study is to understand the relationship between the ultrasound pulse parameters and cavitation properties of flowing microbubbles, including the type (and transition between types), threshold, intensity and temporal distribution of cavitation. An in vitro physiological-flow phantom was fabricated, in which the microbubbles had a constant velocity, and were sonicated to a 1-MHz focused transducer at a wide range of peak negative pressures (PNPs) (0.10-1.28 MPa), pulse repetition frequencies (PRFs) (1-200 Hz) and pulse lengths (PLs) (10-400 μs). The signals from the flowing bubbles were passively detected by another 7.5-MHz plane transducer. From detailed time- and frequency-domain analysis, we found 1). The occurrence of stable cavitation (SC) and inertial cavitation (IC) depended on PNP and PL when the PRF was below a critical value (PRF threshold) that related to the fluid velocity and PNP full width at half maximum diameter of the transducer. 2) Below the PRF threshold, the PL had no influence on the temporal distribution of SC intensity; however, above the PRF threshold, the SC properties depended on the PL because of acoustically-driven diffusion. Specifically, at shorter PLs, the SC intensity had a uniform temporal distribution and was independent of the PRF; at longer PLs, the SC intensity correlated negatively with the PRF. 3) Below the PRF threshold, the IC properties were independent of the PRF. Increasing the PRF above the PRF threshold caused the IC intensity to decrease with a non-uniform temporal distribution. These results indicate that the fluid velocity and a pulsed acoustic field influence the number and properties of the replenished bubbles into the targeted region, resulting in the change of cavitation properties. In future therapeutic applications, the physiological fluid conditions must be taken into consideration to design reasonable pulse parameters and achieve desirable cavitation properties.
Collapse
Affiliation(s)
- Mouwen Cheng
- Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Fan Li
- Department of Medical Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Tao Han
- Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Alfred C H Yu
- Department of Electrical and Computer Engineering, University of Waterloo, Waterloo, ON, Canada
| | - Peng Qin
- Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China.
| |
Collapse
|
59
|
Wear KA. Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part I: Spatiotemporal Transfer Function and Graphical Guide. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:318-339. [PMID: 30530326 PMCID: PMC6935508 DOI: 10.1109/tuffc.2018.2886067] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
The spatiotemporal transfer function for a needle or reflectance-based fiber-optic hydrophone is modeled as separable into the product of two filters corresponding to frequency-dependent sensitivity and spatial averaging. The separable hydrophone transfer function model is verified numerically by comparison to a more general rigid piston spatiotemporal response model that does not assume separability. Spatial averaging effects are characterized by frequency-dependent "effective" sensitive element diameter, which can be more than double the geometrical sensitive element diameter. The transfer function is tested in simulation using a nonlinear focused pressure wave model based on Gaussian harmonic radial pressure distributions. The pressure wave model is validated by comparing to experimental hydrophone scans of nonlinear beams produced by three source transducers. An analytic form for the spatial averaging filter, applicable to Gaussian harmonic beams, is derived. A second analytic form for the spatial averaging filter, applicable to quadratic harmonic beams, is derived by extending the spatial averaging correction recommended by IEC 62127-1 Annex E to nonlinear signals with multiple harmonics. Both forms are applicable to all hydrophones (not just needle and fiber-optic hydrophones). Simulation analysis performed for a wide variety of transducer geometries indicates that the Gaussian spatial averaging filter formula is more accurate than the quadratic formula over a wider range of harmonics. Additional experimental validation is provided in Part II. Readers who are uninterested in hydrophone theory may skip the theoretical and experimental sections of this paper and proceed to the graphical guide for practical information to inform and support selection of hydrophone sensitive element size (but might be well advised to read the Introduction).
Collapse
|
60
|
Hartman RK, Hallam KA, Donnelly EM, Emelianov SY. Photoacoustic imaging of gold nanorods in the brain delivered via microbubble-assisted focused ultrasound: a tool for in vivo molecular neuroimaging. LASER PHYSICS LETTERS 2019; 16:025603. [PMID: 30800031 PMCID: PMC6380671 DOI: 10.1088/1612-202x/aaf89e] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The protective barriers of the CNS present challenges during the treatment and monitoring of diseases. In particular, the blood brain barrier is a major hindrance to the delivery of imaging contrast agents and therapeutics to the brain. In this work, we use gas microbubble-assisted focused ultrasound to transiently open the blood brain barrier and locally deliver silica coated gold nanorods across the barrier. This particular nanoagent possesses a strong optical absorption which enables in vivo and ex vivo visualization of the delivered particles using ultrasound-guided photoacoustic imaging. The results of these studies demonstrate the potential of ultrasound-guided photoacoustics to image contrast agents delivered via microbubble-assisted focused ultrasound for longitudinal diagnostic imaging and for therapeutic monitoring of neurological diseases.
Collapse
Affiliation(s)
- Robin K. Hartman
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Kristina A. Hallam
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, Atlanta, GA, USA
| | - Eleanor M. Donnelly
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Stanislav Y. Emelianov
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, Atlanta, GA, USA
| |
Collapse
|
61
|
Wear KA, Liu Y. Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part II: Experimental Validation of Spatial Averaging Model. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:340-347. [PMID: 30530327 PMCID: PMC6935506 DOI: 10.1109/tuffc.2018.2886071] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Acoustic pressure can be measured with a hydrophone. Hydrophone measurements can underestimate incident acoustic pressure due to spatial averaging effects across the hydrophone sensitive element. The spatial averaging filter for a nonlinear focused beam is a low-pass filter that decreases monotonically from 1 to 0 as frequency increases from 0 to infinity. Experiments were performed to test an analytic model for the spatial averaging filter. Nonlinear pressure tone bursts were generated by three source transducers with driving frequencies ranging from 2.5 to 6 MHz, diameters ranging from 19 to 64 mm, and focal lengths ranging from 38 to 89 mm. The nonlinear pressure fields were measured using four needle hydrophones with nominal geometrical sensitive element diameters of 200, 400, 600, and [Formula: see text]. The average root-mean-square difference between theoretical and experimental spatial averaging filters was 5.8% ± 2.6%.
Collapse
|
62
|
Zhang J, Zheng ZC, Ke G. Time-domain simulation of ultrasound propagation with fractional Laplacians for lossy-medium biological tissues with complicated geometries. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 145:589. [PMID: 30710970 DOI: 10.1121/1.5087826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Accepted: 01/03/2019] [Indexed: 06/09/2023]
Abstract
Simulations of ultrasound wave propagation inside biological tissues have a wide range of practical applications. In previous studies, wave propagation equations in lossy biological media are solved either with convolutions, which consume a large amount of memory, or with pseudo-spectral methods, which cannot handle complicated geometries effectively. The approach described in the paper employed a fractional central difference method (FCD), combined with the immersed boundary (IB) method for the finite-difference, time-domain simulation. The FCD method can solve the fractional Laplace terms in Chen and Holm's lossy-medium equations directly in the physical domain without integral transforms. It also works naturally with the IB method, which enables a simple Cartesian-type grid mesh to be used to solve problems with complicated geometries. The numerical results agree very well with the analytical solutions for frequency power-law attenuation lossy media.
Collapse
Affiliation(s)
- Junjian Zhang
- Department of Aerospace Engineering, University of Kansas, Lawrence, Kansas 66045, USA
| | | | - Guoyi Ke
- Department of Mathematics and Physical Sciences, Louisiana State University of Alexandria, Alexandria, Louisiana 71302, USA
| |
Collapse
|
63
|
Zhang Y, Liao C, Qu H, Huang S, Jiang H, Zhou H, Abrams E, Habte FG, Yuan L, Bertram EH, Lee KS, Pauly KB, Buckmaster PS, Wintermark M. Testing Different Combinations of Acoustic Pressure and Doses of Quinolinic Acid for Induction of Focal Neuron Loss in Mice Using Transcranial Low-Intensity Focused Ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:129-136. [PMID: 30309748 PMCID: PMC6289648 DOI: 10.1016/j.ultrasmedbio.2018.08.023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Revised: 08/21/2018] [Accepted: 08/28/2018] [Indexed: 05/31/2023]
Abstract
The goal of this study was to test different combinations of acoustic pressure and doses of quinolinic acid (QA) for producing a focal neuronal lesion in the murine hippocampus without causing unwanted damage to adjacent brain structures. Sixty male CD-1 mice were divided into 12 groups that underwent magnetic resonance-guided focused ultrasound at high (0.67 MPa), medium (0.5 MPa) and low (0.33 MPa) acoustic peak negative pressures and received QA at high (0.012 mmol), medium (0.006 mmol) and low (0.003 mmol) dosages. Neuronal loss occurred only when magnetic resonance-guided focused ultrasound with adequate acoustic power (0.67 or 0.5 MPa) was combined with QA. The animals subjected to the highest acoustic power had larger lesions than those treated with medium acoustic power, but two mice had evidence of bleeding. When the intermediate acoustic power was used, medium and high dosages of QA produced lesions larger than those produced by the low dosage.
Collapse
Affiliation(s)
- Yanrong Zhang
- Department of Ultrasound, Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science and Technology, China; Neuroradiology Section, Department of Radiology, Stanford University, Stanford, California, USA
| | - Chengde Liao
- Neuroradiology Section, Department of Radiology, Stanford University, Stanford, California, USA; Department of Radiology, Third Affiliated Hospital of Kunming Medical University, Tumor Hospital of Yunnan Province, Kunming, Yunnan, China
| | - Haibo Qu
- Neuroradiology Section, Department of Radiology, Stanford University, Stanford, California, USA; Department of Medical Imaging, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Siqin Huang
- Neuroradiology Section, Department of Radiology, Stanford University, Stanford, California, USA; Traditional Chinese Medicine College, Chongqing Medical University, Chongqing, China
| | - Hong Jiang
- Neuroradiology Section, Department of Radiology, Stanford University, Stanford, California, USA; Department of Neurology, Peking University of People's Hospital, Beijing, China
| | - Haiyan Zhou
- Neuroradiology Section, Department of Radiology, Stanford University, Stanford, California, USA; The Acupuncture and Tuina School/Third Teaching Hospital, Chengdu University of Traditional Chinese Medicine, Chengdu, Sichuan, China
| | - Emily Abrams
- Department of Comparative Medicine, Stanford University, Stanford, California, USA
| | - Frezghi G Habte
- Department of Radiology, Molecular Imaging Program, Stanford University, Stanford, California, USA
| | - Li Yuan
- Department of Ultrasound, Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science and Technology, China
| | - Edward H Bertram
- Department of Neurology, University of Virginia, Charlottesville, Virginia, USA
| | - Kevin S Lee
- Departments of Neuroscience and Neurosurgery and Center for Brain Immunology and Glia, University of Virginia, Charlottesville, Virginia, USA
| | - Kim Butts Pauly
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Paul S Buckmaster
- Department of Comparative Medicine, Stanford University, Stanford, California, USA
| | - Max Wintermark
- Neuroradiology Section, Department of Radiology, Stanford University, Stanford, California, USA.
| |
Collapse
|
64
|
Niu J, Xie J, Guo K, Zhang X, Xia F, Zhao X, Song L, Zhuge D, Li X, Zhao Y, Huang Z. Efficient treatment of Parkinson's disease using ultrasonography-guided rhFGF20 proteoliposomes. Drug Deliv 2018; 25:1560-1569. [PMID: 30043675 PMCID: PMC6060384 DOI: 10.1080/10717544.2018.1482972] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Fibroblast growth factor-20 (FGF20) is a paracrine member of the FGF family that is preferentially expressed in the substantia nigra pars compacta (SNpc). Previous studies have demonstrated that FGF20 enhances the survival of dopaminergic neurons suggesting the potential use of FGF20 to treat Parkinson’s disease (PD). However, the reduced solubility of the bacterial recombinant human FGF20 (rhFGF20) and the absence of efficient strategies to transport rhFGF20 across the blood–brain barrier (BBB) have halted its clinical application. In the present study, we have examined the efficiency of fuzing a small ubiquitin-related modifier (SUMO) to rhFGF20 to enhance its soluble expression and further investigated the efficacy of FUS-guided, rhFGF20-liposome transport across the BBB. We also examined the bioavailability and behavioral improvement in a 6-hydroxydopamine-lesioned rat model of PD following 2 weeks’ FUS-liposomal combinatorial treatment. Our results showed that, in contrast with rhFGF20 or LIP-FGF20, the FUS-LIP-rhFGF20 treatment could significantly improve the apomorphine-induced rotations by protecting against the loss of dopaminergic neurons in the SNpc. Our Results suggest that our combinatorial method would help overcome key challenges that hinder the currently available methods for the use of rhFGF20 in PD treatment.
Collapse
Affiliation(s)
- Jianlou Niu
- a School of Pharmaceutical Sciences & Center for Structural Biology , Wenzhou Medical University , Wenzhou , Zhejiang , China
| | - Junjun Xie
- a School of Pharmaceutical Sciences & Center for Structural Biology , Wenzhou Medical University , Wenzhou , Zhejiang , China
| | - Kaiwen Guo
- a School of Pharmaceutical Sciences & Center for Structural Biology , Wenzhou Medical University , Wenzhou , Zhejiang , China
| | - Xiaomin Zhang
- a School of Pharmaceutical Sciences & Center for Structural Biology , Wenzhou Medical University , Wenzhou , Zhejiang , China
| | - Feng Xia
- a School of Pharmaceutical Sciences & Center for Structural Biology , Wenzhou Medical University , Wenzhou , Zhejiang , China
| | - Xinyu Zhao
- a School of Pharmaceutical Sciences & Center for Structural Biology , Wenzhou Medical University , Wenzhou , Zhejiang , China
| | - Lintao Song
- a School of Pharmaceutical Sciences & Center for Structural Biology , Wenzhou Medical University , Wenzhou , Zhejiang , China
| | - Deli Zhuge
- a School of Pharmaceutical Sciences & Center for Structural Biology , Wenzhou Medical University , Wenzhou , Zhejiang , China
| | - Xiaokun Li
- a School of Pharmaceutical Sciences & Center for Structural Biology , Wenzhou Medical University , Wenzhou , Zhejiang , China
| | - Yingzheng Zhao
- a School of Pharmaceutical Sciences & Center for Structural Biology , Wenzhou Medical University , Wenzhou , Zhejiang , China
| | - Zhifeng Huang
- a School of Pharmaceutical Sciences & Center for Structural Biology , Wenzhou Medical University , Wenzhou , Zhejiang , China
| |
Collapse
|
65
|
Wear KA, Baker C, Miloro P. Directivity and Frequency-Dependent Effective Sensitive Element Size of Needle Hydrophones: Predictions From Four Theoretical Forms Compared With Measurements. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:1781-1788. [PMID: 30010557 PMCID: PMC6175646 DOI: 10.1109/tuffc.2018.2855967] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Directivity is a hydrophone specification that describes response as a function of angle of incidence. The goal of this study was to compare, in the context of needle hydrophones, the commonly used rigid baffle model for hydrophone directivity to three alternative models: soft baffle, unbaffled (UB), and rigid piston (RP). Directivity measurements were performed at 1, 2, 3, 4, 6, 8, and 10 MHz from ±7° in two orthogonal planes for two ceramic and two polymer needle hydrophones with nominal geometrical sensitive element diameters of 200, 400, 600, and 1000 . Effective hydrophone sensitive element radius was estimated by least-squares fitting the four models to directivity measurement data using the sensitive element radius (a) as an adjustable parameter. For > 4 (where and = wavelength), the RP model outperformed the other three models. For , the average error in estimated sensitive element radius was 7% [95% confidence interval (CI): 3%-12%] for the RP model while the lowest average error by the other three models was 46% (95% CI: 38%-54%) for the UB model.
Collapse
Affiliation(s)
- Keith A. Wear
- U.S. Food and Drug Administration, Silver Spring, MD, 20993 ()
| | | | - Piero Miloro
- National Physical Laboratory, Teddington, U.K.. ()
| |
Collapse
|
66
|
Zhang J, Lin X, Zhou H, Chen Y, Xiao S, Jiao J, Zhao Y, Di Z. Electroacupuncture: a new approach to open the blood-brain barrier in rats recovering from middle cerebral artery occlusion. Acupunct Med 2018; 36:377-385. [PMID: 29903719 PMCID: PMC6287560 DOI: 10.1136/acupmed-2017-011496] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/16/2018] [Indexed: 12/25/2022]
Abstract
Objective To examine for an opening effect on the blood–brain barrier (BBB) in intact rats and rats with experimental ischaemia-reperfusion (I/R) during the recovery period after various electroacupuncture (EA) treatments with different time courses, and to determine whether there is a time-dependent effect. An additional objective was to determine whether this method could induce the penetration of nerve growth factor (NGF) through the BBB. Methods A middle cerebral artery occlusion (MCAO) model was first established. We chose different stimulation time courses and observed the effects of EA treatment (100 Hz frequency; 2 mA intensity) at GV20 and GV26 on the BBB in rats recovering from MCAO 3 weeks after modelling. The rats were injected with 2% Evans blue (EB) saline. The brain water content was measured using a wet/dry weighing method. The degree of penetration of EB was detected using spectrophotometry and laser confocal microscopy. The rats were then injected with NGF, and the concentration of NGF in the brain tissues was measured using ELISA. Results The increase in the BBB permeability was most notable following the 8 min EA stimulation (P<0.05), which may be advantageous for the targeted delivery of drugs (such as NGF) into the brain. Additionally, this effect did not appear to cause brain oedema (P>0.05) in healthy or MCAO rats. Conclusions EA treatment for a certain stimulation time at GV20 and GV26 in MCAO rats can increase BBB permeability.
Collapse
Affiliation(s)
- Jiangsong Zhang
- The Third Clinical Medical College, Zhejiang Chinese Medical University, Department of Neurobiology and Acupuncture Research, Hangzhou, China
| | - Xianming Lin
- The Third Clinical Medical College, Zhejiang Chinese Medical University, Department of Neurobiology and Acupuncture Research, Hangzhou, China
| | - Hui Zhou
- The Third Clinical Medical College, Zhejiang Chinese Medical University, Department of Neurobiology and Acupuncture Research, Hangzhou, China
| | - Yuanyuan Chen
- The Third Clinical Medical College, Zhejiang Chinese Medical University, Department of Neurobiology and Acupuncture Research, Hangzhou, China
| | - Shuangkai Xiao
- The Third Clinical Medical College, Zhejiang Chinese Medical University, Department of Neurobiology and Acupuncture Research, Hangzhou, China
| | - Junyue Jiao
- The Third Clinical Medical College, Zhejiang Chinese Medical University, Department of Neurobiology and Acupuncture Research, Hangzhou, China
| | - Yibin Zhao
- The Third Clinical Medical College, Zhejiang Chinese Medical University, Department of Neurobiology and Acupuncture Research, Hangzhou, China
| | - Zhong Di
- The Third Clinical Medical College, Zhejiang Chinese Medical University, Department of Neurobiology and Acupuncture Research, Hangzhou, China
| |
Collapse
|
67
|
Munoz F, Aurup C, Konofagou EE, Ferrera VP. Modulation of Brain Function and Behavior by Focused Ultrasound. Curr Behav Neurosci Rep 2018; 5:153-164. [PMID: 30393592 PMCID: PMC6208352 DOI: 10.1007/s40473-018-0156-7] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
PURPOSE OF REVIEW The past decade has seen rapid growth in the application of focused ultrasound (FUS) as a tool for basic neuroscience research and potential treatment of brain disorders. Here, we review recent developments in our understanding of how FUS can alter brain activity, perception and behavior when applied to the central nervous system, either alone or in combination with circulating agents. RECENT FINDINGS Focused ultrasound in the central nervous system can directly excite or inhibit neuronal activity, as well as affect perception and behavior. Combining FUS with intravenous microbubbles to open the blood-brain barrier also affects neural activity and behavior, and the effects may be more sustained than FUS alone. Opening the BBB also allows delivery of drugs that do not cross the intact BBB including viral vectors for gene delivery. SUMMARY While further research is needed to elucidate the biophysical mechanisms, focused ultrasound, alone or in combination with other factors, is rapidly maturing as an effective technology for altering brain activity. Future challenges include refining control over targeting specificity, the volume of affected tissue, cell-type specificity (excitatory or inhibitory), and the duration of neural and behavioral effects.
Collapse
Affiliation(s)
- Fabian Munoz
- Department of Neuroscience, Columbia University, New York, NY, 10027 USA
- Zuckerman Mind Brain Behavior Institute, Columbia University, New York, NY, 10027 USA
- Kavli Institute for Brain Science, Columbia University, New York, NY, 10027 USA
| | - Christian Aurup
- Department of Biomedical Engineering, Columbia University, New York, NY, 10027 USA
| | - Elisa E Konofagou
- Department of Biomedical Engineering, Columbia University, New York, NY, 10027 USA
- Department of Radiology, Columbia University, New York, NY, 10027 USA
| | - Vincent P Ferrera
- Department of Neuroscience, Columbia University, New York, NY, 10027 USA
- Zuckerman Mind Brain Behavior Institute, Columbia University, New York, NY, 10027 USA
- Kavli Institute for Brain Science, Columbia University, New York, NY, 10027 USA
- Department of Psychiatry, Columbia University, New York, NY, 10027 USA
| |
Collapse
|
68
|
Gorick CM, Sheybani ND, Curley CT, Price RJ. Listening in on the Microbubble Crowd: Advanced Acoustic Monitoring for Improved Control of Blood-Brain Barrier Opening with Focused Ultrasound. Theranostics 2018; 8:2988-2991. [PMID: 29897053 PMCID: PMC5996352 DOI: 10.7150/thno.26025] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2018] [Accepted: 03/12/2018] [Indexed: 01/21/2023] Open
Abstract
Non-invasive drug and gene delivery to the brain to treat central nervous system pathologies has long been inhibited by the blood-brain barrier. The activation of microbubbles with focused ultrasound has emerged as a promising non-invasive approach to circumvent this obstacle, by transiently disrupting the blood-brain barrier and permitting passage of systemically administered therapeutics into the tissue. Clinical trials are underway to evaluate the safety of this technique; however, concerns remain regarding the potential for the treatment to induce sterile inflammation or petechiae. In this issue of Theranostics, Jones et al.[1] address these concerns through the development of an advanced three-dimensional imaging system for monitoring acoustic emissions from oscillating microbubbles. When subharmonic emissions are detected with this system, focused ultrasound pressure is reduced by 50% for the remainder of the treatment. This serves to transiently open the blood-brain barrier without generating adverse effects. While the ideal configuration of the transducer array for treatment and monitoring still presents an area for further optimization, the approach indicates that the acoustic signature of microbubble behavior within the skull can be used to ensure safe and effective blood-brain barrier opening using focused ultrasound.
Collapse
Affiliation(s)
| | | | | | - Richard J. Price
- Department of Biomedical Engineering, University of Virginia, Charlottesville, VA
| |
Collapse
|
69
|
Pelekanos M, Leinenga G, Odabaee M, Odabaee M, Saifzadeh S, Steck R, Götz J. Establishing sheep as an experimental species to validate ultrasound-mediated blood-brain barrier opening for potential therapeutic interventions. Am J Cancer Res 2018; 8:2583-2602. [PMID: 29721100 PMCID: PMC5928910 DOI: 10.7150/thno.22852] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Accepted: 03/02/2018] [Indexed: 11/14/2022] Open
Abstract
Rationale: Treating diseases of the brain such as Alzheimer's disease (AD) is challenging as the blood-brain barrier (BBB) effectively restricts access of a large number of potentially useful drugs. A potential solution to this problem is presented by therapeutic ultrasound, a novel treatment modality that can achieve transient BBB opening in species including rodents, facilitated by biologically inert microbubbles that are routinely used in a clinical setting for contrast enhancement. However, in translating rodent studies to the human brain, the presence of a thick cancellous skull that both absorbs and distorts ultrasound presents a challenge. A larger animal model that is more similar to humans is therefore required in order to establish a suitable protocol and to test devices. Here we investigated whether sheep provide such a model. Methods: In a stepwise manner, we used a total of 12 sheep to establish a sonication protocol using a spherically focused transducer. This was assisted by ex vivo simulations based on CT scans to establish suitable sonication parameters. BBB opening was assessed by Evans blue staining and a range of histological tests. Results: Here we demonstrate noninvasive microbubble-mediated BBB opening through the intact sheep skull. Our non-recovery protocol allowed for BBB opening at the base of the brain, and in areas relevant for AD, including the cortex and hippocampus. Linear time-shift invariant analysis and finite element analysis simulations were used to optimize the position of the transducer and to predict the acoustic pressure and location of the focus. Conclusion: Our study establishes sheep as a novel animal model for ultrasound-mediated BBB opening and highlights opportunities and challenges in using this model. Moreover, as sheep develop an AD-like pathology with aging, they represent a large animal model that could potentially complement the use of non-human primates.
Collapse
|
70
|
Sonodynamic therapy (SDT): a novel strategy for cancer nanotheranostics. SCIENCE CHINA-LIFE SCIENCES 2018; 61:415-426. [PMID: 29666990 DOI: 10.1007/s11427-017-9262-x] [Citation(s) in RCA: 147] [Impact Index Per Article: 24.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Accepted: 12/15/2017] [Indexed: 12/14/2022]
Abstract
Sonodynamic therapy (SDT) is a promising non-invasive therapeutic modality. Compared to photo-inspired therapy, SDT provides many opportunities and benefits, including deeper tissue penetration, high precision, less side effects, and good patient compliance. Thanks to the facile engineerable nature of nanotechnology, nanoparticles-based sonosensitizers exhibit predominant advantages, such as increased SDT efficacy, binding avidity, and targeting specificity. This review aims to summarize the possible mechanisms of SDT, which can be expected to provide the theoretical basis for SDT development in the future. We also extensively discuss nanoparticle-assisted sonosensitizers to enhance the outcome of SDT. Additionally, we focus on the potential strategy of combinational SDT with other therapeutic modalities and discuss the limitations and challenges of SDT toward clinical applications.
Collapse
|
71
|
D'Arrigo JS. Targeting Early Dementia: Using Lipid Cubic Phase Nanocarriers to Cross the Blood⁻Brain Barrier. Biomimetics (Basel) 2018; 3:E4. [PMID: 31105226 PMCID: PMC6352688 DOI: 10.3390/biomimetics3010004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Revised: 02/21/2018] [Accepted: 03/06/2018] [Indexed: 12/14/2022] Open
Abstract
Over the past decades, a frequent co-morbidity of cerebrovascular pathology and Alzheimer's disease has been observed. Numerous published studies indicate that the preservation of a healthy cerebrovascular endothelium can be an important therapeutic target. By incorporating the appropriate drug(s) into biomimetic (lipid cubic phase) nanocarriers, one obtains a multitasking combination therapeutic, which targets certain cell surface scavenger receptors, mainly class B type I (i.e., SR-BI), and crosses the blood⁻brain barrier. This targeting allows for various cell types related to Alzheimer's to be simultaneously searched out for localized drug treatment in vivo.
Collapse
|
72
|
Image-Guided Focused-Ultrasound CNS Molecular Delivery: An Implementation via Dynamic Contrast-Enhanced Magnetic-Resonance Imaging. Sci Rep 2018. [PMID: 29515222 PMCID: PMC5841286 DOI: 10.1038/s41598-018-22571-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
Focused ultrasound (FUS) exposure with microbubbles can transiently open the blood-brain barrier (BBB) to deliver therapeutic molecules into CNS tissues. However, delivered molecular distribution/concentration at the target need to be controlled. Dynamic Contrast-Enhanced Magnetic-Resonance Imaging (DCE-MRI) is a well-established protocol for monitoring the pharmacokinetic/pharmacodynamic behavior of FUS-BBB opening. This study investigates the feasibility of using DCE-MRI to estimate molecular CNS penetration under various exposure conditions and molecule sizes. In the 1st stage, a relationship among the imaging index Ktrans, exposure level and molecular size was calibrated and established. In the 2nd stage, various exposure levels and distinct molecules were applied to evaluate the estimated molecular concentration discrepancy with the quantified ones. High correlation (r2 = 0.9684) between Ktrans and transcranial mechanical index (MI) implies Ktrans can serve as an in vivo imaging index to mirror FUS-BBB opening scale. When testing various molecules with the size ranging 1–149 kDa, an overall correlation of r2 = 0.9915 between quantified and predicted concentrations was reached, suggesting the established model can provide reasonably accurate estimation. Our work demonstrates the feasibility of estimating molecular penetration through FUS-BBB opening via DCE-MRI and may facilitate development of FUS-induced BBB opening in brain drug delivery.
Collapse
|
73
|
Peruzzi G, Sinibaldi G, Silvani G, Ruocco G, Casciola CM. Perspectives on cavitation enhanced endothelial layer permeability. Colloids Surf B Biointerfaces 2018; 168:83-93. [PMID: 29486912 DOI: 10.1016/j.colsurfb.2018.02.027] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2017] [Revised: 02/06/2018] [Accepted: 02/11/2018] [Indexed: 12/20/2022]
Abstract
Traditional drug delivery systems, where pharmaceutical agents are conveyed to the target tissue through the blood circulation, suffer of poor therapeutic efficiency and limited selectivity largely due to the low permeability of the highly specialised biological interface represented by the endothelial layer. Examples concern cancer therapeutics or degenerative disorders where drug delivery is inhibited by the blood-brain barrier (BBB). Microbubbles injected into the bloodstream undergo volume oscillations under localised ultrasound irradiation and possibly collapse near the site of interest, with no effect on the rest of the endothelium. The resulting mechanical action induces a transient increase of the inter-cellular spaces and facilitates drug extravasation. This approach, already pursed in in vivo animal models, is extremely expensive and time-consuming. On the other hand in vitro studies using different kinds of microfluidic networks are firmly established in the pharmaceutical industry for drug delivery testing. The combination of the in vitro approach with ultrasound used to control microbubbles oscillations is expected to provide crucial information for developing cavitation enhanced drug delivery protocols and for screening the properties of the biological interface in presence of healthy or diseased tissues. Purpose of the present review is providing the state of the art in this rapidly growing field where cavitation is exploited as a viable technology to transiently modify the permeability of the biological interface. After describing current in vivo studies, particular emphasis will be placed on illustrating characteristics of micro-devices, biological functionalisation, properties of the artificial endothelium and ultrasound irradiation techniques.
Collapse
Affiliation(s)
- Giovanna Peruzzi
- Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Rome, Italy
| | - Giorgia Sinibaldi
- Department of Mechanical and Aerospace Engineering, Sapienza University of Rome, Italy
| | - Giulia Silvani
- Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Rome, Italy; Department of Mechanical and Aerospace Engineering, Sapienza University of Rome, Italy
| | - Giancarlo Ruocco
- Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Rome, Italy; Department of Physics, Sapienza University of Rome, Italy.
| | - Carlo Massimo Casciola
- Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Rome, Italy; Department of Mechanical and Aerospace Engineering, Sapienza University of Rome, Italy
| |
Collapse
|
74
|
Leinenga G, Götz J. Safety and Efficacy of Scanning Ultrasound Treatment of Aged APP23 Mice. Front Neurosci 2018; 12:55. [PMID: 29467614 PMCID: PMC5808306 DOI: 10.3389/fnins.2018.00055] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2017] [Accepted: 01/23/2018] [Indexed: 01/11/2023] Open
Abstract
Deposition of amyloid-β (Aβ) peptide leads to amyloid plaques that together with tau deposits characterize the brains of patients with Alzheimer's disease (AD). In modeling this pathology, transgenic animals such as the APP23 strain, that expresses a mutant form of the amyloid precursor protein found in familial cases of AD, have been instrumental. In previous studies, we have shown that repeated treatments with ultrasound in a scanning mode (termed scanning ultrasound or SUS) were effective in removing Aβ and restoring memory functions, without the need for a therapeutic agent such as an Aβ antibody. Considering that age is the most important risk factor for AD, we extended this study in which the mice were only 12 months old at the time of treatment by assessing a cohort of 2 year-old mice. Interestingly, at this age, APP23 mice are characterized by cerebral amyloid angiopathy (CAA) and the presence of occasional microbleeds. We found that SUS in aged mice that have been exposed to four SUS sessions that were spread out over 8 weeks and analyzed 4 weeks later did not show evidence of increased CAA or microbleeds. Furthermore, amyloid was reduced as assessed by methoxy-XO4 fluorescence. In addition, plaque-associated microglia were more numerous in SUS treated mice. Together this adds to the notion that SUS may be a treatment modality for human neurodegenerative diseases.
Collapse
Affiliation(s)
- Gerhard Leinenga
- Clem Jones Centre for Ageing Dementia Research, Queensland Brain Institute, University of Queensland, Brisbane, QLD, Australia
| | - Jürgen Götz
- Clem Jones Centre for Ageing Dementia Research, Queensland Brain Institute, University of Queensland, Brisbane, QLD, Australia
| |
Collapse
|
75
|
Wu SY, Fix SM, Arena CB, Chen CC, Zheng W, Olumolade OO, Papadopoulou V, Novell A, Dayton PA, Konofagou EE. Focused ultrasound-facilitated brain drug delivery using optimized nanodroplets: vaporization efficiency dictates large molecular delivery. Phys Med Biol 2018; 63:035002. [PMID: 29260735 DOI: 10.1088/1361-6560/aaa30d] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Focused ultrasound with nanodroplets could facilitate localized drug delivery after vaporization with potentially improved in vivo stability, drug payload, and minimal interference outside of the focal zone compared with microbubbles. While the feasibility of blood-brain barrier (BBB) opening using nanodroplets has been previously reported, characterization of the associated delivery has not been achieved. It was hypothesized that the outcome of drug delivery was associated with the droplet's sensitivity to acoustic energy, and can be modulated with the boiling point of the liquid core. Therefore, in this study, octafluoropropane (OFP) and decafluorobutane (DFB) nanodroplets were used both in vitro for assessing their relative vaporization efficiency with high-speed microscopy, and in vivo for delivering molecules with a size relevant to proteins (40 kDa dextran) to the murine brain. It was found that at low pressures (300-450 kPa), OFP droplets vaporized into a greater number of microbubbles compared to DFB droplets at higher pressures (750-900 kPa) in the in vitro study. In the in vivo study, successful delivery was achieved with OFP droplets at 300 kPa and 450 kPa without evidence of cavitation damage using ¼ dosage, compared to DFB droplets at 900 kPa where histology indicated tissue damage due to inertial cavitation. In conclusion, the vaporization efficiency of nanodroplets positively impacted the amount of molecules delivered to the brain. The OFP droplets due to the higher vaporization efficiency served as better acoustic agents to deliver large molecules efficiently to the brain compared with the DFB droplets.
Collapse
Affiliation(s)
- Shih-Ying Wu
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, United States of America
| | | | | | | | | | | | | | | | | | | |
Collapse
|
76
|
Qin P, Han T, Yu ACH, Xu L. Mechanistic understanding the bioeffects of ultrasound-driven microbubbles to enhance macromolecule delivery. J Control Release 2018; 272:169-181. [PMID: 29305924 DOI: 10.1016/j.jconrel.2018.01.001] [Citation(s) in RCA: 110] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2017] [Revised: 01/02/2018] [Accepted: 01/03/2018] [Indexed: 12/17/2022]
Abstract
Ultrasound-driven microbubbles can trigger reversible membrane perforation (sonoporation), open interendothelial junctions and stimulate endocytosis, thereby providing a temporary and reversible time-window for the delivery of macromolecules across biological membranes and endothelial barriers. This time-window is related not only to cavitation events, but also to biological regulatory mechanisms. Mechanistic understanding of the interaction between cavitation events and cells and tissues, as well as the subsequent cellular and molecular responses will lead to new design strategies with improved efficacy and minimized side effects. Recent important progress on the spatiotemporal characteristics of sonoporation, cavitation-induced interendothelial gap and endocytosis, and the spatiotemporal bioeffects and the preliminary biological mechanisms in cavitation-enhanced permeability, has been made. On the basis of the summary of this research progress, this Review outlines the underlying bioeffects and the related biological regulatory mechanisms involved in cavitation-enhanced permeability; provides a critical commentary on the future tasks and directions in this field, including developing a standardized methodology to reveal mechanism-based bioeffects in depth, and designing biology-based treatment strategies to improve efficacy and safety. Such mechanistic understanding the bioeffects that contribute to cavitation-enhanced delivery will accelerate the translation of this approach to the clinic.
Collapse
Affiliation(s)
- Peng Qin
- Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China.
| | - Tao Han
- Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Alfred C H Yu
- Department of Electrical and Computer Engineering, University of Waterloo, Waterloo, ON, Canada
| | - Lin Xu
- National Key Laboratory of Plant Molecular Genetics, CAS Center for Excellence in Molecular Plant Sciences, Institute of Plant Physiology and Ecology, Shanghai Institutes for Biological Sciences, Chinese Academy of Sciences, Shanghai, China
| |
Collapse
|
77
|
Fu BM. Transport Across the Blood-Brain Barrier. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2018; 1097:235-259. [PMID: 30315549 DOI: 10.1007/978-3-319-96445-4_13] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
The blood-brain barrier (BBB) is a dynamic barrier essential for maintaining the microenvironment of the brain. Although the special anatomical features of the BBB determine its protective role for the central nervous system (CNS) from blood-borne neurotoxins, however, the BBB extremely limits the therapeutic efficacy of drugs into the CNS, which greatly hinders the treatment of major brain diseases. This chapter summarized the unique structures of the BBB; described a variety of in vivo and in vitro experimental methods for determining the transport properties of the BBB and the permeability of the BBB to water, ions, and solutes including nutrients, therapeutic agents, and drug carriers; and presented recently developed mathematical models which quantitatively correlate the anatomical structures of the BBB with its barrier functions. Recent findings for modulation of the BBB permeability by chemical and physical stimuli were described. Finally, drug delivery strategies through specific trans-BBB routes were discussed.
Collapse
Affiliation(s)
- Bingmei M Fu
- Department of Biomedical Engineering, The City College of the City University of New York, New York, NY, USA.
| |
Collapse
|
78
|
Nanotherapy for Alzheimer's disease and vascular dementia: Targeting senile endothelium. Adv Colloid Interface Sci 2018; 251:44-54. [PMID: 29274774 DOI: 10.1016/j.cis.2017.12.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2017] [Revised: 12/01/2017] [Accepted: 12/02/2017] [Indexed: 12/12/2022]
Abstract
Due to the complexity of Alzheimer's disease, multiple cellular types need to be targeted simultaneously in order for a given therapy to demonstrate any major effectiveness. Ultrasound-sensitive coated microbubbles (in a targeted lipid nanoemulsion) are available. Versatile small molecule drug(s) targeting multiple pathways of Alzheimer's disease pathogenesis are known. By incorporating such drug(s) into the targeted "lipid-coated microbubble" [LCM]/"nanoparticle-derived" [ND] (or LCM/ND) nanoemulsion type, one obtains a multitasking combination therapeutic for translational medicine. This multitasking therapeutic targets cell-surface scavenger receptors (mainly class B type I), or SR-BI, making possible for various Alzheimer's-related cell types to be simultaneously searched out for localized drug treatment in vivo. Besides targeting cell-surface SR-BI, the proposed LCM/ND-nanoemulsion combination therapeutic(s) include a characteristic lipid-coated microbubble [LCM] subpopulation (i.e., a stable LCM suspension); such film-stabilized microbubbles are well known to substantially reduce the acoustic power levels needed for accomplishing temporary noninvasive (transcranial) ultrasound treatment, or sonoporation, if additionally desired for the Alzheimer's patient.
Collapse
|
79
|
Alzheimer’s Disease, Brain Injury, and C.N.S. Nanotherapy in Humans: Sonoporation Augmenting Drug Targeting. Med Sci (Basel) 2017. [PMCID: PMC5753658 DOI: 10.3390/medsci5040029] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Owing to the complexity of neurodegenerative diseases, multiple cellular types need to be targeted simultaneously in order for a given therapy to demonstrate any major effectiveness. Ultrasound-sensitive coated microbubbles (in a targeted nanoemulsion) are available. Versatile small-molecule drug(s) targeting multiple pathways of Alzheimer’s disease pathogenesis are known. By incorporating such drug(s) into the targeted lipid-coated microbubble/nanoparticle-derived (LCM/ND) lipid nanoemulsion type, one obtains a multitasking combination therapeutic for translational medicine. This multitasking therapeutic targets cell-surface scavenger receptors (mainly scavenger receptor class B type I (SR-BI)), making it possible for various Alzheimer’s-related cell types to be simultaneously sought for localized drug treatment in vivo. Besides targeting cell-surface SR-BI, the proposed LCM/ND-nanoemulsion combination therapeutic(s) include a characteristic lipid-coated microbubble (LCM) subpopulation (i.e., a stable LCM suspension); such LCM substantially reduce the acoustic power levels needed for accomplishing temporary noninvasive (transcranial) ultrasound treatment, or sonoporation, if additionally desired for the Alzheimer’s patient.
Collapse
|
80
|
Lazarus C, Pouliopoulos AN, Tinguely M, Garbin V, Choi JJ. Clustering dynamics of microbubbles exposed to low-pressure 1-MHz ultrasound. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2017; 142:3135. [PMID: 29195473 DOI: 10.1121/1.5010170] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Ultrasound-driven microbubbles have been used in therapeutic applications to deliver drugs across capillaries and into cells or to dissolve blood clots. Yet the performance and safety of these applications have been difficult to control. Microbubbles exposed to ultrasound not only volumetrically oscillate, but also move due to acoustic radiation, or Bjerknes, forces. The purpose of this work was to understand the extent to which microbubbles moved and clustered due to secondary Bjerknes forces. A microbubble population was exposed to a 1-MHz ultrasound pulse with a peak-rarefactional pressure of 50-100 kPa and a pulse length of 20 ms. Microbubbles exposed to low-pressure therapeutic ultrasound were observed to cluster at clustering rates of 0.01-0.02 microbubbles per duration (in ms) per initial average inter-bubble distance (in μm), resulting in 1 to 3 clustered microbubbles per initial average inter-bubble distance (in μm). Higher pressures caused faster clustering rates and a larger number of clustered microbubbles. Experimental data revealed clustering time scales, cluster localizations, and cluster sizes that were in reasonable agreement with simulations using a time-averaged model at low pressures. This study demonstrates that clustering of microbubbles occurs within a few milliseconds and is likely to influence the distribution of stimuli produced in therapeutic applications.
Collapse
Affiliation(s)
- Carole Lazarus
- Bioengineering Department, Imperial College London, London SW7 2BP, United Kingdom
| | | | - Marc Tinguely
- Chemical Engineering Department, Imperial College London, London SW7 2AZ, United Kingdom
| | - Valeria Garbin
- Chemical Engineering Department, Imperial College London, London SW7 2AZ, United Kingdom
| | - James J Choi
- Bioengineering Department, Imperial College London, London SW7 2BP, United Kingdom
| |
Collapse
|
81
|
Fishman PS. Thalamotomy for essential tremor: FDA approval brings brain treatment with FUS to the clinic. J Ther Ultrasound 2017; 5:19. [PMID: 28717511 PMCID: PMC5508673 DOI: 10.1186/s40349-017-0096-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2016] [Accepted: 04/14/2017] [Indexed: 12/05/2022] Open
Affiliation(s)
- Paul S Fishman
- Department of Neurology, University of Maryland School of Medicine, Baltimore, MD 21201 USA
| |
Collapse
|
82
|
Fishman PS, Frenkel V. Treatment of Movement Disorders With Focused Ultrasound. J Cent Nerv Syst Dis 2017; 9:1179573517705670. [PMID: 28615985 PMCID: PMC5462491 DOI: 10.1177/1179573517705670] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2016] [Accepted: 03/28/2017] [Indexed: 11/29/2022] Open
Abstract
Although the use of ultrasound as a potential therapeutic modality in the brain has been under study for several decades, relatively few neuroscientists or neurologists are familiar with this technology. Stereotactic brain lesioning had been widely used as a treatment for medically refractory patients with essential tremor (ET), Parkinson disease (PD), and dystonia but has been largely replaced by deep brain stimulation (DBS) surgery, with advantages both in safety and efficacy. However, DBS is associated with complications including intracerebral hemorrhage, infection, and hardware malfunction. The occurrence of these complications has spurred interest in less invasive stereotactic brain lesioning methods including magnetic resonance imaging–guided high intensity–focused ultrasound (FUS) surgery. Engineering advances now allow sound waves to be targeted noninvasively through the skull to a brain target. High intensities of sonic energy can create a coagulation lesion similar to that of older radiofrequency stereotactic methods, but without opening the skull, recent Food and Drug Administration approval of unilateral thalamotomy for treatment of ET. Clinical studies of stereotactic FUS for aspects of PD are underway. Moderate intensity, pulsed FUS has also demonstrated the potential to safely open the blood-brain barrier for localized delivery of therapeutics including proteins, genes, and cell-based therapy for PD and related disorders. The goal of this review is to provide basic and clinical neuroscientists with a level of understanding to interact with medical physicists, biomedical engineers, and radiologists to accelerate the application of this powerful technology to brain disease
Collapse
Affiliation(s)
- Paul S Fishman
- Department of Neurology, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Victor Frenkel
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, MD, USA
| |
Collapse
|
83
|
Fishman PS, Frenkel V. Focused Ultrasound: An Emerging Therapeutic Modality for Neurologic Disease. Neurotherapeutics 2017; 14:393-404. [PMID: 28244011 PMCID: PMC5398988 DOI: 10.1007/s13311-017-0515-1] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Therapeutic ultrasound is only beginning to be applied to neurologic conditions, but the potential of this modality for a wide spectrum of brain applications is high. Engineering advances now allow sound waves to be targeted through the skull to a brain region selected with real time magnetic resonance imaging and thermography, using a commercial array of focused emitters. High intensities of sonic energy can create a coagulation lesion similar to that of older radiofrequency stereotactic methods, but without opening the skull. This has led to the recent Food and Drug Administration approval of focused ultrasound (FUS) thalamotomy for unilateral treatment of essential tremor. Clinical studies of stereotactic FUS for aspects of Parkinson's disease, chronic pain, and refractory psychiatric indications are underway, with promising results. Moderate-intensity FUS has the potential to safely open the blood-brain barrier for localized delivery of therapeutics, while low levels of sonic energy can be used as a form of neuromodulation.
Collapse
Affiliation(s)
- Paul S Fishman
- Department of Neurology, University of Maryland School of Medicine, Baltimore, MD, 21201, USA.
| | - Victor Frenkel
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, MD, 21201, USA
| |
Collapse
|
84
|
Timbie KF, Afzal U, Date A, Zhang C, Song J, Wilson Miller G, Suk JS, Hanes J, Price RJ. MR image-guided delivery of cisplatin-loaded brain-penetrating nanoparticles to invasive glioma with focused ultrasound. J Control Release 2017; 263:120-131. [PMID: 28288892 DOI: 10.1016/j.jconrel.2017.03.017] [Citation(s) in RCA: 65] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2016] [Revised: 02/21/2017] [Accepted: 03/08/2017] [Indexed: 12/24/2022]
Abstract
Systemically administered chemotherapeutic drugs are often ineffective in the treatment of invasive brain tumors due to poor therapeutic index. Within gliomas, despite the presence of heterogeneously leaky microvessels, dense extracellular matrix and high interstitial pressure generate a "blood-tumor barrier" (BTB), which inhibits drug delivery and distribution. Meanwhile, beyond the contrast MRI-enhancing edge of the tumor, invasive cancer cells are protected by the intact blood-brain barrier (BBB). Here, we tested whether brain-penetrating nanoparticles (BPN) that possess dense surface coatings of polyethylene glycol (PEG) and are loaded with cisplatin (CDDP) could be delivered across both the blood-tumor and blood-brain barriers with MR image-guided focused ultrasound (MRgFUS), and whether this treatment could control glioma growth and invasiveness. To this end, we first established that MRgFUS is capable of significantly enhancing the delivery of ~60nm fluorescent tracer BPN across the blood-tumor barrier in both the 9L (6-fold improvement) gliosarcoma and invasive F98 (28-fold improvement) glioma models. Importantly, BPN delivery across the intact BBB, just beyond the tumor edge, was also markedly increased in both tumor models. We then showed that a CDDP loaded BPN formulation (CDDP-BPN), composed of a blend of polyaspartic acid (PAA) and heavily PEGylated polyaspartic acid (PAA-PEG), was highly stable, provided extended drug release, and was effective against F98 cells in vitro. These CDDP-BPN were delivered from the systemic circulation into orthotopic F98 gliomas using MRgFUS, where they elicited a significant reduction in tumor invasiveness and growth, as well as improved animal survival. We conclude that this therapy may offer a powerful new approach for the treatment invasive gliomas, particularly for preventing and controlling recurrence.
Collapse
Affiliation(s)
- Kelsie F Timbie
- Department of Biomedical Engineering, University of Virginia, 415 Lane Road Building MR5, Charlottesville, VA 22908, United States
| | - Umara Afzal
- Department of Ophthalmology, The Johns Hopkins University School of Medicine, 600 N. Wolfe Street, Baltimore, MD 21287, United States; Center for Nanomedicine, The Johns Hopkins University School of Medicine, 600 N. Wolfe Street, Baltimore, MD 21287, United States; Department of Biochemistry, PMAS-Arid Agriculture University, Shamsabad, Muree Road, Rawalpindi, Pakistan
| | - Abhijit Date
- Department of Ophthalmology, The Johns Hopkins University School of Medicine, 600 N. Wolfe Street, Baltimore, MD 21287, United States; Center for Nanomedicine, The Johns Hopkins University School of Medicine, 600 N. Wolfe Street, Baltimore, MD 21287, United States
| | - Clark Zhang
- Department of Ophthalmology, The Johns Hopkins University School of Medicine, 600 N. Wolfe Street, Baltimore, MD 21287, United States; Center for Nanomedicine, The Johns Hopkins University School of Medicine, 600 N. Wolfe Street, Baltimore, MD 21287, United States
| | - Ji Song
- Department of Biomedical Engineering, University of Virginia, 415 Lane Road Building MR5, Charlottesville, VA 22908, United States
| | - G Wilson Miller
- Department of Radiology and Medical Imaging, University of Virginia, 480 Ray C Hunt Drive, Charlottesville, VA 22908, United States
| | - Jung Soo Suk
- Department of Ophthalmology, The Johns Hopkins University School of Medicine, 600 N. Wolfe Street, Baltimore, MD 21287, United States; Center for Nanomedicine, The Johns Hopkins University School of Medicine, 600 N. Wolfe Street, Baltimore, MD 21287, United States
| | - Justin Hanes
- Department of Ophthalmology, The Johns Hopkins University School of Medicine, 600 N. Wolfe Street, Baltimore, MD 21287, United States; Center for Nanomedicine, The Johns Hopkins University School of Medicine, 600 N. Wolfe Street, Baltimore, MD 21287, United States
| | - Richard J Price
- Department of Biomedical Engineering, University of Virginia, 415 Lane Road Building MR5, Charlottesville, VA 22908, United States.
| |
Collapse
|
85
|
Luan L, Wei X, Zhao Z, Siegel JJ, Potnis O, Tuppen CA, Lin S, Kazmi S, Fowler RA, Holloway S, Dunn AK, Chitwood RA, Xie C. Ultraflexible nanoelectronic probes form reliable, glial scar-free neural integration. SCIENCE ADVANCES 2017; 3:e1601966. [PMID: 28246640 PMCID: PMC5310823 DOI: 10.1126/sciadv.1601966] [Citation(s) in RCA: 299] [Impact Index Per Article: 42.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2016] [Accepted: 01/10/2017] [Indexed: 05/19/2023]
Abstract
Implanted brain electrodes construct the only means to electrically interface with individual neurons in vivo, but their recording efficacy and biocompatibility pose limitations on scientific and clinical applications. We showed that nanoelectronic thread (NET) electrodes with subcellular dimensions, ultraflexibility, and cellular surgical footprints form reliable, glial scar-free neural integration. We demonstrated that NET electrodes reliably detected and tracked individual units for months; their impedance, noise level, single-unit recording yield, and the signal amplitude remained stable during long-term implantation. In vivo two-photon imaging and postmortem histological analysis revealed seamless, subcellular integration of NET probes with the local cellular and vasculature networks, featuring fully recovered capillaries with an intact blood-brain barrier and complete absence of chronic neuronal degradation and glial scar.
Collapse
Affiliation(s)
- Lan Luan
- Department of Physics, the University of Texas at Austin, Austin, TX 78712–1192, USA
| | - Xiaoling Wei
- Department of Biomedical Engineering, the University of Texas at Austin, Austin, TX 78712–1192, USA
| | - Zhengtuo Zhao
- Department of Biomedical Engineering, the University of Texas at Austin, Austin, TX 78712–1192, USA
| | - Jennifer J. Siegel
- Center for Learning and Memory, Institute for Neuroscience, the University of Texas at Austin, Austin, TX 78712–1192, USA
| | - Ojas Potnis
- Department of Biomedical Engineering, the University of Texas at Austin, Austin, TX 78712–1192, USA
| | - Catherine A Tuppen
- Department of Biomedical Engineering, the University of Texas at Austin, Austin, TX 78712–1192, USA
| | - Shengqing Lin
- Department of Biomedical Engineering, the University of Texas at Austin, Austin, TX 78712–1192, USA
| | - Shams Kazmi
- Department of Biomedical Engineering, the University of Texas at Austin, Austin, TX 78712–1192, USA
| | - Robert A. Fowler
- Department of Biomedical Engineering, the University of Texas at Austin, Austin, TX 78712–1192, USA
| | - Stewart Holloway
- Department of Biomedical Engineering, the University of Texas at Austin, Austin, TX 78712–1192, USA
| | - Andrew K. Dunn
- Department of Biomedical Engineering, the University of Texas at Austin, Austin, TX 78712–1192, USA
| | - Raymond A. Chitwood
- Center for Learning and Memory, Institute for Neuroscience, the University of Texas at Austin, Austin, TX 78712–1192, USA
| | - Chong Xie
- Department of Biomedical Engineering, the University of Texas at Austin, Austin, TX 78712–1192, USA
- Corresponding author.
| |
Collapse
|
86
|
Aryal M, Fischer K, Gentile C, Gitto S, Zhang YZ, McDannold N. Effects on P-Glycoprotein Expression after Blood-Brain Barrier Disruption Using Focused Ultrasound and Microbubbles. PLoS One 2017; 12:e0166061. [PMID: 28045902 PMCID: PMC5207445 DOI: 10.1371/journal.pone.0166061] [Citation(s) in RCA: 99] [Impact Index Per Article: 14.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2016] [Accepted: 10/21/2016] [Indexed: 12/31/2022] Open
Abstract
Many blood-borne substances attempting to pass through the luminal membrane of brain endothelial cells are acted upon by a variety of metabolizing enzymes or are actively expelled back into the capillary lumen by embedded efflux transporters, such as Permeability-glycoprotein (Pgp). Overexpression of this protein has also been linked to multidrug resistance in cancer cells. Previous studies have shown that focused ultrasound (FUS), when combined with a microbubble agent, has ability to temporarily disrupt blood-brain barrier (BBBD). In this work, we investigated whether modulation of Pgp expression is part of the FUS-induced effects. We found that ultrasound can temporarily suppress Pgp expression. When BBBD was produced at 0.55 MPa, Pgp was suppressed up to 48 hours and restored by 72 hours. At 0.81 MPa, suppression can last 72 hours or longer. These findings support the idea that microbubble-enhanced FUS disrupts the functional components of the BBB through suppression of drug efflux.
Collapse
Affiliation(s)
- Muna Aryal
- Department of Radiology, Brigham & Women’s Hospital, Harvard Medical School, Boston, United States of America
| | - Krisztina Fischer
- Department of Radiology, Brigham & Women’s Hospital, Harvard Medical School, Boston, United States of America
| | - Caroline Gentile
- Department of Radiology, Brigham & Women’s Hospital, Harvard Medical School, Boston, United States of America
- Department of Neurobiology, Harvard College, Cambridge, United States of America
| | | | - Yong-Zhi Zhang
- Department of Radiology, Brigham & Women’s Hospital, Harvard Medical School, Boston, United States of America
| | - Nathan McDannold
- Department of Radiology, Brigham & Women’s Hospital, Harvard Medical School, Boston, United States of America
| |
Collapse
|
87
|
Kovacs ZI, Kim S, Jikaria N, Qureshi F, Milo B, Lewis BK, Bresler M, Burks SR, Frank JA. Disrupting the blood-brain barrier by focused ultrasound induces sterile inflammation. Proc Natl Acad Sci U S A 2017; 114:E75-E84. [PMID: 27994152 PMCID: PMC5224365 DOI: 10.1073/pnas.1614777114] [Citation(s) in RCA: 276] [Impact Index Per Article: 39.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
MRI-guided pulsed focused ultrasound (pFUS) combined with systemic infusion of ultrasound contrast agent microbubbles (MB) causes localized blood-brain barrier (BBB) disruption that is currently being advocated for increasing drug or gene delivery in neurological diseases. The mechanical acoustic cavitation effects of opening the BBB by low-intensity pFUS+MB, as evidenced by contrast-enhanced MRI, resulted in an immediate damage-associated molecular pattern (DAMP) response including elevations in heat-shock protein 70, IL-1, IL-18, and TNFα indicative of a sterile inflammatory response (SIR) in the parenchyma. Concurrent with DAMP presentation, significant elevations in proinflammatory, antiinflammatory, and trophic factors along with neurotrophic and neurogenesis factors were detected; these elevations lasted 24 h. Transcriptomic analysis of sonicated brain supported the proteomic findings and indicated that the SIR was facilitated through the induction of the NFκB pathway. Histological evaluation demonstrated increased albumin in the parenchyma that cleared by 24 h along with TUNEL+ neurons, activated astrocytes, microglia, and increased cell adhesion molecules in the vasculature. Infusion of fluorescent beads 3 d before pFUS+MB revealed the infiltration of CD68+ macrophages at 6 d postsonication, as is consistent with an innate immune response. pFUS+MB is being considered as part of a noninvasive adjuvant treatment for malignancy or neurodegenerative diseases. These results demonstrate that pFUS+MB induces an SIR compatible with ischemia or mild traumatic brain injury. Further investigation will be required before this approach can be widely implemented in clinical trials.
Collapse
Affiliation(s)
- Zsofia I Kovacs
- Frank Laboratory, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892;
| | - Saejeong Kim
- Frank Laboratory, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892
| | - Neekita Jikaria
- Frank Laboratory, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892
| | - Farhan Qureshi
- Frank Laboratory, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892
| | - Blerta Milo
- Frank Laboratory, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892
| | - Bobbi K Lewis
- Frank Laboratory, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892
| | - Michele Bresler
- Frank Laboratory, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892
| | - Scott R Burks
- Frank Laboratory, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892
| | - Joseph A Frank
- Frank Laboratory, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892;
- National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD 20892
| |
Collapse
|
88
|
Song KH, Fan AC, Hinkle JJ, Newman J, Borden MA, Harvey BK. Microbubble gas volume: A unifying dose parameter in blood-brain barrier opening by focused ultrasound. Am J Cancer Res 2017; 7:144-152. [PMID: 28042323 PMCID: PMC5196892 DOI: 10.7150/thno.15987] [Citation(s) in RCA: 73] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2016] [Accepted: 08/18/2016] [Indexed: 11/05/2022] Open
Abstract
Focused ultrasound with microbubbles is being developed to transiently, locally and noninvasively open the blood-brain barrier (BBB) for improved pharmaceutical delivery. Prior work has demonstrated that, for a given concentration dose, microbubble size affects both the intravascular circulation persistence and extent of BBB opening. When matched to gas volume dose, however, the circulation half-life was found to be independent of microbubble size. In order to determine whether this holds true for BBB opening as well, we independently measured the effects of microbubble size (2 vs. 6 µm diameter) and concentration, covering a range of overlapping gas volume doses (1-40 µL/kg). We first demonstrated precise targeting and a linear dose-response of Evans Blue dye extravasation to the rat striatum for a set of constant microbubble and ultrasound parameters. We found that dye extravasation increased linearly with gas volume dose, with data points from both microbubble sizes collapsing to a single line. A linear trend was observed for both the initial sonication (R2=0.90) and a second sonication on the contralateral side (R2=0.68). Based on these results, we conclude that microbubble gas volume dose, not size, determines the extent of BBB opening by focused ultrasound (1 MHz, ~0.5 MPa at the focus). This result may simplify planning for focused ultrasound treatments by constraining the protocol to a single microbubble parameter - gas volume dose - which gives equivalent results for varying size distributions. Finally, using optimal parameters determined for Evan Blue, we demonstrated gene delivery and expression using a viral vector, dsAAV1-CMV-EGFP, one week after BBB disruption, which allowed us to qualitatively evaluate neuronal health.
Collapse
|
89
|
Mulvana H, Browning RJ, Luan Y, de Jong N, Tang MX, Eckersley RJ, Stride E. Characterization of Contrast Agent Microbubbles for Ultrasound Imaging and Therapy Research. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:232-251. [PMID: 27810805 DOI: 10.1109/tuffc.2016.2613991] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
The high efficiency with which gas microbubbles can scatter ultrasound compared with the surrounding blood pool or tissues has led to their widespread employment as contrast agents in ultrasound imaging. In recent years, their applications have been extended to include super-resolution imaging and the stimulation of localized bio-effects for therapy. The growing exploitation of contrast agents in ultrasound and in particular these recent developments have amplified the need to characterize and fully understand microbubble behavior. The aim in doing so is to more fully exploit their utility for both diagnostic imaging and potential future therapeutic applications. This paper presents the key characteristics of microbubbles that determine their efficacy in diagnostic and therapeutic applications and the corresponding techniques for their measurement. In each case, we have presented information regarding the methods available and their respective strengths and limitations, with the aim of presenting information relevant to the selection of appropriate characterization methods. First, we examine methods for determining the physical properties of microbubble suspensions and then techniques for acoustic characterization of both suspensions and single microbubbles. The next section covers characterization of microbubbles as therapeutic agents, including as drug carriers for which detailed understanding of their surface characteristics and drug loading capacity is required. Finally, we discuss the attempts that have been made to allow comparison across the methods employed by various groups to characterize and describe their microbubble suspensions and promote wider discussion and comparison of microbubble behavior.
Collapse
|
90
|
Hatch RJ, Leinenga G, Götz J. Scanning Ultrasound (SUS) Causes No Changes to Neuronal Excitability and Prevents Age-Related Reductions in Hippocampal CA1 Dendritic Structure in Wild-Type Mice. PLoS One 2016; 11:e0164278. [PMID: 27727310 PMCID: PMC5058555 DOI: 10.1371/journal.pone.0164278] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2016] [Accepted: 09/22/2016] [Indexed: 01/09/2023] Open
Abstract
Scanning ultrasound (SUS) is a noninvasive approach that has recently been shown to ameliorate histopathological changes and restore memory functions in an Alzheimer's disease mouse model. Although no overt neuronal damage was reported, the short- and long-term effects of SUS on neuronal excitability and dendritic tree morphology had not been investigated. To address this, we performed patch-clamp recordings from hippocampal CA1 pyramidal neurons in wild-type mice 2 and 24 hours after a single SUS treatment, and one week and 3 months after six weekly SUS treatments, including sham treatments as controls. In both treatment regimes, no changes in CA1 neuronal excitability were observed in SUS-treated neurons when compared to sham-treated neurons at any time-point. For the multiple treatment groups, we also determined the dendritic morphology and spine densities of the neurons from which we had recorded. The apical trees of sham-treated neurons were reduced at the 3 month time-point when compared to one week; however, surprisingly, no longitudinal change was detected in the apical dendritic trees of SUS-treated neurons. In contrast, the length and complexity of the basal dendritic trees were not affected by SUS treatment at either time-point. The apical dendritic spine densities were reduced, independent of the treatment group, at 3 months compared to one week. Collectively, these data suggest that ultrasound can be employed to prevent an age-associated loss of dendritic structure without impairing neuronal excitability.
Collapse
Affiliation(s)
- Robert John Hatch
- Clem Jones Centre for Ageing Dementia Research, Queensland Brain Institute, The University of Queensland, St Lucia Campus, Brisbane, QLD 4072, Australia
| | - Gerhard Leinenga
- Clem Jones Centre for Ageing Dementia Research, Queensland Brain Institute, The University of Queensland, St Lucia Campus, Brisbane, QLD 4072, Australia
| | - Jürgen Götz
- Clem Jones Centre for Ageing Dementia Research, Queensland Brain Institute, The University of Queensland, St Lucia Campus, Brisbane, QLD 4072, Australia
- * E-mail:
| |
Collapse
|
91
|
Pouliopoulos AN, Li C, Tinguely M, Garbin V, Tang MX, Choi JJ. Rapid short-pulse sequences enhance the spatiotemporal uniformity of acoustically driven microbubble activity during flow conditions. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 140:2469. [PMID: 27794288 DOI: 10.1121/1.4964271] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Despite the promise of microbubble-mediated focused ultrasound therapies, in vivo findings have revealed over-treated and under-treated regions distributed throughout the focal volume. This poor distribution cannot be improved by conventional pulse shapes and sequences, due to their limited ability to control acoustic cavitation dynamics within the ultrasonic focus. This paper describes the design of a rapid short-pulse (RaSP) sequence which is comprised of short pulses separated by μs off-time intervals. Improved acoustic cavitation distribution was based on the hypothesis that microbubbles can freely move during the pulse off-times. Flowing SonoVue® microbubbles (flow velocity: 10 mm/s) were sonicated with a 0.5 MHz focused ultrasound transducer using RaSP sequences (peak-rarefactional pressures: 146-900 kPa, pulse repetition frequency: 1.25 kHz, and pulse lengths: 5-50 cycles). The distribution of cavitation activity was evaluated using passive acoustic mapping. RaSP sequences generated uniform distributions within the focus in contrast to long pulses (50 000 cycles) that produced non-uniform distributions. Fast microbubble destruction occurred for long pulses, whereas microbubble activity was sustained for longer durations for shorter pulses. High-speed microscopy revealed increased mobility in the direction of flow during RaSP sonication. In conclusion, RaSP sequences produced spatiotemporally uniform cavitation distributions and could result in efficient therapies by spreading cavitation throughout the treatment area.
Collapse
Affiliation(s)
| | - Caiqin Li
- Bioengineering Department, Imperial College London, London, SW7 2BP, United Kingdom
| | - Marc Tinguely
- Chemical Engineering Department, Imperial College London, London SW7 2AZ, United Kingdom
| | - Valeria Garbin
- Chemical Engineering Department, Imperial College London, London SW7 2AZ, United Kingdom
| | - Meng-Xing Tang
- Bioengineering Department, Imperial College London, London SW7 2BP, United Kingdom
| | - James J Choi
- Bioengineering Department, Imperial College London, London SW7 2BP, United Kingdom
| |
Collapse
|
92
|
Focused Ultrasound-Induced Blood-Brain Barrier Opening: Association with Mechanical Index and Cavitation Index Analyzed by Dynamic Contrast-Enhanced Magnetic-Resonance Imaging. Sci Rep 2016; 6:33264. [PMID: 27630037 PMCID: PMC5024096 DOI: 10.1038/srep33264] [Citation(s) in RCA: 77] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2016] [Accepted: 08/22/2016] [Indexed: 01/07/2023] Open
Abstract
Focused ultrasound (FUS) with microbubbles can temporally open the blood-brain barrier (BBB), and the cavitation activities of microbubbles play a key role in the BBB-opening process. Previous attempts used contrast-enhanced magnetic resonance imaging (CE-MRI) to correlate the mechanical index (MI) with the scale of BBB-opening, but MI only partially gauged acoustic activities, and CE-MRI did not fully explore correlations of pharmacodynamic/pharmacokinetic behaviors. Recently, the cavitation index (CI) has been derived to serve as an indicator of microbubble-ultrasound stable cavitation, and may also serve as a valid indicator to gauge the level of FUS-induced BBB opening. This study investigates the feasibility of gauging FUS-induced BBB opened level via the two indexes, MI and CI, through dynamic contrast-enhanced (DCE)-MRI analysis as well as passive cavitation detection (PCD) analysis. Pharmacodynamic/pharmacokinetic parameters derived from DCE-MRI were characterized to identify the scale of FUS-induced BBB opening. Our results demonstrated that DCE-MRI can successfully access pharmacodynamic/pharmacokinetic BBB-opened behavior, and was highly correlated both with MI and CI, implying the feasibility in using these two indices to gauge the scale of FUS-induced BBB opening. The proposed finding may facilitate the design toward using focused ultrasound as a safe and reliable noninvasive CNS drug delivery.
Collapse
|
93
|
Hynynen K, Jones RM. Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy. Phys Med Biol 2016; 61:R206-48. [PMID: 27494561 PMCID: PMC5022373 DOI: 10.1088/0031-9155/61/17/r206] [Citation(s) in RCA: 78] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Focused ultrasound offers a non-invasive way of depositing acoustic energy deep into the body, which can be harnessed for a broad spectrum of therapeutic purposes, including tissue ablation, the targeting of therapeutic agents, and stem cell delivery. Phased array transducers enable electronic control over the beam geometry and direction, and can be tailored to provide optimal energy deposition patterns for a given therapeutic application. Their use in combination with modern medical imaging for therapy guidance allows precise targeting, online monitoring, and post-treatment evaluation of the ultrasound-mediated bioeffects. In the past there have been some technical obstacles hindering the construction of large aperture, high-power, densely-populated phased arrays and, as a result, they have not been fully exploited for therapy delivery to date. However, recent research has made the construction of such arrays feasible, and it is expected that their continued development will both greatly improve the safety and efficacy of existing ultrasound therapies as well as enable treatments that are not currently possible with existing technology. This review will summarize the basic principles, current statures, and future potential of image-guided ultrasound phased arrays for therapy.
Collapse
Affiliation(s)
- Kullervo Hynynen
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada. Department of Medical Biophysics, University of Toronto, Toronto, Canada. Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Canada
| | | |
Collapse
|
94
|
Unilateral Opening of Rat Blood-Brain Barrier Assisted by Diagnostic Ultrasound Targeted Microbubbles Destruction. BIOMED RESEARCH INTERNATIONAL 2016; 2016:4759750. [PMID: 27579317 PMCID: PMC4989062 DOI: 10.1155/2016/4759750] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/29/2016] [Revised: 05/31/2016] [Accepted: 06/08/2016] [Indexed: 12/23/2022]
Abstract
Objective. Blood-brain barrier (BBB) is a key obstacle that prevents the medication from blood to the brain. Microbubble-enhanced cavitation by focused ultrasound can open the BBB and proves to be valuable in the brain drug delivery. The study aimed to explore the feasibility, efficacy, and safety of unilateral opening of BBB using diagnostic ultrasound targeted microbubbles destruction in rats. Methods. A transtemporal bone irradiation of diagnostic ultrasound and intravenous injection of lipid-coated microbubbles were performed at unilateral hemisphere. Pathological changes were monitored. Evans Blue extravasation grades, extraction from brain tissue, and fluorescence optical density were quantified. Lanthanum nitrate was traced by transmission electron microscopy. Results. After diagnostic ultrasound mediated microbubbles destruction, Evans Blue extravasation and fluorescence integrated optical density were significantly higher in the irradiated hemisphere than the contralateral side (all p < 0.01). Erythrocytes extravasations were demonstrated in the ultrasound-exposed hemisphere (4 ± 1, grade 2) while being invisible in the control side. Lanthanum nitrate tracers leaked through interendothelial cleft and spread to the nerve fiber existed in the irradiation side. Conclusions. Transtemporal bone irradiation under DUS mediated microbubble destruction provides us with a more accessible, safer, and higher selective BBB opening approach in rats, which is advantageous in brain targeted drugs delivery.
Collapse
|
95
|
Pouliopoulos AN, Choi JJ. Superharmonic microbubble Doppler effect in ultrasound therapy. Phys Med Biol 2016; 61:6154-71. [PMID: 27469394 PMCID: PMC5390953 DOI: 10.1088/0031-9155/61/16/6154] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Revised: 05/24/2016] [Accepted: 06/14/2016] [Indexed: 12/23/2022]
Abstract
The introduction of microbubbles in focused ultrasound therapies has enabled a diverse range of non-invasive technologies: sonoporation to deliver drugs into cells, sonothrombolysis to dissolve blood clots, and blood-brain barrier opening to deliver drugs into the brain. Current methods for passively monitoring the microbubble dynamics responsible for these therapeutic effects can identify the cavitation position by passive acoustic mapping and cavitation mode by spectral analysis. Here, we introduce a new feature that can be monitored: microbubble effective velocity. Previous studies have shown that echoes from short imaging pulses had a Doppler shift that was produced by the movement of microbubbles. Therapeutic pulses are longer (>1 000 cycles) and thus produce a larger alteration of microbubble distribution due to primary and secondary acoustic radiation force effects which cannot be monitored using pulse-echo techniques. In our experiments, we captured and analyzed the Doppler shift during long therapeutic pulses using a passive cavitation detector. A population of microbubbles (5 × 10(4)-5 × 10(7) microbubbles ml(-1)) was embedded in a vessel (inner diameter: 4 mm) and sonicated using a 0.5 MHz focused ultrasound transducer (peak-rarefactional pressure: 75-366 kPa, pulse length: 50 000 cycles or 100 ms) within a water tank. Microbubble acoustic emissions were captured with a coaxially aligned 7.5 MHz passive cavitation detector and spectrally analyzed to measure the Doppler shift for multiple harmonics above the 10th harmonic (i.e. superharmonics). A Doppler shift was observed on the order of tens of kHz with respect to the primary superharmonic peak and is due to the axial movement of the microbubbles. The position, amplitude and width of the Doppler peaks depended on the acoustic pressure and the microbubble concentration. Higher pressures increased the effective velocity of the microbubbles up to 3 m s(-1), prior to the onset of broadband emissions, which is an indicator for high magnitude inertial cavitation. Although the microbubble redistribution was shown to persist for the entire sonication period in dense populations, it was constrained to the first few milliseconds in lower concentrations. In conclusion, superharmonic microbubble Doppler effects can provide a quantitative measure of effective velocities of a sonicated microbubble population and could be used for monitoring ultrasound therapy in real-time.
Collapse
Affiliation(s)
- Antonios N Pouliopoulos
- Noninvasive Surgery and Biopsy laboratory, Bioengineering Department, Imperial College London, London SW7 2AZ, UK
| | - James J Choi
- Noninvasive Surgery and Biopsy laboratory, Bioengineering Department, Imperial College London, London SW7 2AZ, UK
| |
Collapse
|
96
|
Abstract
Ultrasonic waves can be non-invasively steered and focused into mm-scale regions across the human body and brain, and their application in generating controlled artificial modulation of neuronal activity could therefore potentially have profound implications for neural science and engineering. Ultrasonic neuro-modulation phenomena were experimentally observed and studied for nearly a century, with recent discoveries on direct neural excitation and suppression sparking a new wave of investigations in models ranging from rodents to humans. In this paper we review the physics, engineering and scientific aspects of ultrasonic fields, their control in both space and time, and their effect on neuronal activity, including a survey of both the field's foundational history and of recent findings. We describe key constraints encountered in this field, as well as key engineering systems developed to surmount them. In closing, the state of the art is discussed, with an emphasis on emerging research and clinical directions.
Collapse
Affiliation(s)
- Omer Naor
- Department of Biomedical Engineering, The Technion-Israel Institute of Technology Haifa 32000, Israel. The Edmond and Lily Safra Center for Brain Sciences (ELSC), The Hebrew University of Jerusalem, Jerusalem 91220, Israel
| | | | | |
Collapse
|
97
|
Abstract
Like cardiovascular disease and cancer, neurological disorders present an increasing challenge for an ageing population. Whereas nonpharmacological procedures are routine for eliminating cancer tissue or opening a blocked artery, the focus in neurological disease remains on pharmacological interventions. Setbacks in clinical trials and the obstacle of access to the brain for drug delivery and surgery have highlighted the potential for therapeutic use of ultrasound in neurological diseases, and the technology has proved useful for inducing focused lesions, clearing protein aggregates, facilitating drug uptake, and modulating neuronal function. In this Review, we discuss milestones in the development of therapeutic ultrasound, from the first steps in the 1950s to recent improvements in technology. We provide an overview of the principles of diagnostic and therapeutic ultrasound, for surgery and transient opening of the blood-brain barrier, and its application in clinical trials of stroke, Parkinson disease and chronic pain. We discuss the promising outcomes of safety and feasibility studies in preclinical models, including rodents, pigs and macaques, and efficacy studies in models of Alzheimer disease. We also consider the challenges faced on the road to clinical translation.
Collapse
|
98
|
Yu FTH, Chen X, Wang J, Qin B, Villanueva FS. Low Intensity Ultrasound Mediated Liposomal Doxorubicin Delivery Using Polymer Microbubbles. Mol Pharm 2015; 13:55-64. [PMID: 26567985 DOI: 10.1021/acs.molpharmaceut.5b00421] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Cardiotoxicity is the major dose-limiting factor in the chemotherapeutic use of doxorubicin (Dox). A delivery vehicle that can be triggered to release its payload in the tumoral microvasculature but not in healthy tissue would help improve the therapeutic window of the drug. Delivery strategies combining liposomal encapsulated Dox (LDox), microbubbles (MBs), and ultrasound (US) have been shown to improve therapeutic efficacy of LDox, but much remains to be known about the mechanisms and the US conditions that maximize cytotoxicity using this approach. In this study, we compared different US pulses in terms of drug release and acute toxicity. Drug uptake and proliferation rates using low-intensity US were measured in squamous cell carcinoma cells exposed to LDox conjugated to or coinjected with polymer MBs. The aims of this study were: (1) to compare the effects of low- and high-pressure US on Dox release kinetics; (2) to evaluate whether conjugating the liposome to the MB surface (DoxLPX) is an important factor for drug release and cytotoxicity; and (3) to determine which US parameters most inhibit cell proliferation and whether this inhibition is mediated by drug release or the MB/US interaction with cells. Low-pressure US (170 kPa) at high duty cycle (stable cavitation) released up to ∼ 70% of the encapsulated Dox from the DoxLPX, thus improving Dox bioavailability and cellular uptake and leading to a significant reduction in cell proliferation at 48 h. Flow cytometry showed that US generating stable oscillations of DoxLPX significantly increased cellular Dox uptake at 4 h after US exposure compared to LDox. Drug uptake was correlated with cytotoxicity at 48 h. Our results demonstrate that Dox-containing liposomes conjugated to polymer MBs can be triggered to release ∼ 70% of their payload using noninertial US. Following release, Dox became bioavailable to the cells and induced significantly higher cytotoxicity compared to nonreleased encapsulated drug. Our findings show promise for targeted drug delivery using this theranostic delivery platform at low US intensities.
Collapse
Affiliation(s)
- Francois T H Yu
- Center for Ultrasound Molecular Imaging and Therapeutics, University of Pittsburgh , Pittsburgh, Pennsylvania 15213, United States
| | - Xucai Chen
- Center for Ultrasound Molecular Imaging and Therapeutics, University of Pittsburgh , Pittsburgh, Pennsylvania 15213, United States
| | - Jianjun Wang
- Center for Ultrasound Molecular Imaging and Therapeutics, University of Pittsburgh , Pittsburgh, Pennsylvania 15213, United States
| | - Bin Qin
- Center for Ultrasound Molecular Imaging and Therapeutics, University of Pittsburgh , Pittsburgh, Pennsylvania 15213, United States
| | - Flordeliza S Villanueva
- Center for Ultrasound Molecular Imaging and Therapeutics, University of Pittsburgh , Pittsburgh, Pennsylvania 15213, United States
| |
Collapse
|
99
|
Leinenga G, Götz J. Scanning ultrasound removes amyloid-β and restores memory in an Alzheimer's disease mouse model. Sci Transl Med 2015; 7:278ra33. [PMID: 25761889 DOI: 10.1126/scitranslmed.aaa2512] [Citation(s) in RCA: 339] [Impact Index Per Article: 37.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Amyloid-β (Aβ) peptide has been implicated in the pathogenesis of Alzheimer's disease (AD). We present a nonpharmacological approach for removing Aβ and restoring memory function in a mouse model of AD in which Aβ is deposited in the brain. We used repeated scanning ultrasound (SUS) treatments of the mouse brain to remove Aβ, without the need for any additional therapeutic agent such as anti-Aβ antibody. Spinning disk confocal microscopy and high-resolution three-dimensional reconstruction revealed extensive internalization of Aβ into the lysosomes of activated microglia in mouse brains subjected to SUS, with no concomitant increase observed in the number of microglia. Plaque burden was reduced in SUS-treated AD mice compared to sham-treated animals, and cleared plaques were observed in 75% of SUS-treated mice. Treated AD mice also displayed improved performance on three memory tasks: the Y-maze, the novel object recognition test, and the active place avoidance task. Our findings suggest that repeated SUS is useful for removing Aβ in the mouse brain without causing overt damage, and should be explored further as a noninvasive method with therapeutic potential in AD.
Collapse
Affiliation(s)
- Gerhard Leinenga
- Clem Jones Centre for Ageing Dementia Research, Queensland Brain Institute, The University of Queensland, St Lucia Campus, Brisbane, Queensland 4072, Australia
| | - Jürgen Götz
- Clem Jones Centre for Ageing Dementia Research, Queensland Brain Institute, The University of Queensland, St Lucia Campus, Brisbane, Queensland 4072, Australia.
| |
Collapse
|
100
|
In-vivo imaging of blood–brain barrier permeability using positron emission tomography with 2-amino-[3-11C]isobutyric acid. Nucl Med Commun 2015; 36:1239-48. [DOI: 10.1097/mnm.0000000000000385] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|