• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4619809)   Today's Articles (2938)   Subscriber (49404)
For: Devic S, Seuntjens J, Sham E, Podgorsak EB, Schmidtlein CR, Kirov AS, Soares CG. Precise radiochromic film dosimetry using a flat-bed document scanner. Med Phys 2005;32:2245-2253. [PMID: 16121579 DOI: 10.1118/1.1929253] [Citation(s) in RCA: 441] [Impact Index Per Article: 23.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2004] [Revised: 04/19/2005] [Accepted: 04/20/2005] [Indexed: 11/07/2022]  Open
Number Cited by Other Article(s)
101
A new facility for proton radiobiology at the Trento proton therapy centre: Design and implementation. Phys Med 2019;58:99-106. [DOI: 10.1016/j.ejmp.2019.02.001] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2018] [Revised: 02/04/2019] [Accepted: 02/05/2019] [Indexed: 01/26/2023]  Open
102
Rohani SA, Mahdavi SR, Mostaar A, Ueltzhöffer S, Mohammadi R, Geraily G. Physical and Dosimetric Aspect of Euromechanics Add-on Multileaf Collimator on Varian Clinac 2100 C/D. J Biomed Phys Eng 2019;9:29-36. [PMID: 30881932 PMCID: PMC6409378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2018] [Accepted: 11/20/2018] [Indexed: 06/09/2023]
103
Quality assurance of volumetric-modulated arc therapy head and neck cancer treatment using PRESAGE® dosimeter. JOURNAL OF RADIOTHERAPY IN PRACTICE 2018. [DOI: 10.1017/s146039691800016x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
104
Falahati F, Nickfarjam A, Shabani M. A Feasibility Study of IMRT of Lung Cancer Using Gafchromic EBT3 Film. J Biomed Phys Eng 2018;8:347-356. [PMID: 30568924 PMCID: PMC6280119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2017] [Accepted: 11/26/2017] [Indexed: 06/09/2023]
105
Volotskova O, Fang X, Keidar M, Chandarana H, Das IJ. Microstructure changes in radiochromic films due to magnetic field and radiation. Med Phys 2018;46:293-301. [PMID: 30341911 DOI: 10.1002/mp.13248] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2018] [Revised: 10/01/2018] [Accepted: 10/05/2018] [Indexed: 11/10/2022]  Open
106
Guardiola C, Prezado Y, Roulin C, Bergs JW. Effect of X-ray minibeam radiation therapy on clonogenic survival of glioma cells. Clin Transl Radiat Oncol 2018;13:7-13. [PMID: 30211325 PMCID: PMC6134191 DOI: 10.1016/j.ctro.2018.07.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2018] [Revised: 07/26/2018] [Accepted: 07/31/2018] [Indexed: 01/02/2023]  Open
107
Hill R, Healy B, Butler D, Odgers D, Gill S, Lye J, Gorjiara T, Pope D, Hill B. Australasian recommendations for quality assurance in kilovoltage radiation therapy from the Kilovoltage Dosimetry Working Group of the Australasian College of Physical Scientists and Engineers in Medicine. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2018;41:781-808. [DOI: 10.1007/s13246-018-0692-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
108
Tagiling N, Ab Rashid R, Azhan SNA, Dollah N, Geso M, Rahman WN. Effect of scanning parameters on dose-response of radiochromic films irradiated with photon and electron beams. Heliyon 2018;4:e00864. [PMID: 30364574 PMCID: PMC6197593 DOI: 10.1016/j.heliyon.2018.e00864] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Revised: 08/11/2018] [Accepted: 10/11/2018] [Indexed: 12/04/2022]  Open
109
Ade N, du Plessis F. Electron beam dose perturbations caused by diode detectors used for in vivo dosimetry: Gafchromic film dose measurements in a realistic pelvic prosthesis phantom. Radiat Phys Chem Oxf Engl 1993 2018. [DOI: 10.1016/j.radphyschem.2018.06.043] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
110
Ade N, Oderinde O, du Plessis F. Monte Carlo dose in a prosthesis phantom based on exact geometry vs streak artefact contaminated CT data as benchmarked against Gafchromic film measurements. Phys Med 2018;54:94-102. [DOI: 10.1016/j.ejmp.2018.09.124] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2018] [Revised: 09/10/2018] [Accepted: 09/28/2018] [Indexed: 11/26/2022]  Open
111
Liu PZY, Nguyen DT, Feain I, O'Brien R, Keall PJ, Booth JT. Technical Note: Real-time image-guided adaptive radiotherapy of a rigid target for a prototype fixed beam radiotherapy system. Med Phys 2018;45:4660-4666. [DOI: 10.1002/mp.13143] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Revised: 08/15/2018] [Accepted: 08/15/2018] [Indexed: 12/29/2022]  Open
112
Famulari G, Renaud MA, Poole CM, Evans MDC, Seuntjens J, Enger SA. RapidBrachyMCTPS: a Monte Carlo-based treatment planning system for brachytherapy applications. ACTA ACUST UNITED AC 2018;63:175007. [DOI: 10.1088/1361-6560/aad97a] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
113
Osman AFI, Jalbout W. Correction factors for diode and diamond detectors in the measurement of small field output factors, using film dosimetry as reference. Biomed Phys Eng Express 2018;4. [DOI: 10.1088/2057-1976/aad5a5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Accepted: 07/25/2018] [Indexed: 11/12/2022]
114
Marants R, Vandervoort E, Cygler JE. Evaluation of the 4D RADPOS dosimetry system for dose and position quality assurance of CyberKnife. Med Phys 2018;45:4030-4044. [PMID: 30043980 DOI: 10.1002/mp.13102] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2018] [Revised: 07/09/2018] [Accepted: 07/10/2018] [Indexed: 02/28/2024]  Open
115
Alhakeem E, Zavgorodni S. Output and ($k_{{{Q}_{{\rm clin},}}{{Q}_{{\rm msr}}}}^{{{\,f}_{{\rm clin},}}{{f}_{{\rm msr}}}}$ ) correction factors measured and calculated in very small circular fields for microDiamond and EFD-3G detectors. ACTA ACUST UNITED AC 2018;63:155002. [DOI: 10.1088/1361-6560/aacfb2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
116
Stewart JMP, Stapleton S, Chaudary N, Lindsay PE, Jaffray DA. Spatial frequency performance limitations of radiation dose optimization and beam positioning. Phys Med Biol 2018;63:125006. [PMID: 29762137 DOI: 10.1088/1361-6560/aac501] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
117
Impact of dose engine algorithm in pencil beam scanning proton therapy for breast cancer. Phys Med 2018;50:7-12. [DOI: 10.1016/j.ejmp.2018.05.018] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2018] [Revised: 05/04/2018] [Accepted: 05/17/2018] [Indexed: 11/19/2022]  Open
118
León‐Marroquín EY, Lárraga‐Gutiérrez JM, Herrera‐González JA, Camacho‐López MA, Villarreal Barajas JE, García‐Garduño OA. Investigation of EBT3 radiochromic film's response to humidity. J Appl Clin Med Phys 2018;19:283-290. [PMID: 29707904 PMCID: PMC5978557 DOI: 10.1002/acm2.12337] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Revised: 01/10/2018] [Accepted: 03/20/2018] [Indexed: 11/18/2022]  Open
119
Comparison of dose response functions for EBT3 model GafChromic™ film dosimetry system. Phys Med 2018;49:112-118. [DOI: 10.1016/j.ejmp.2018.05.014] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Revised: 05/10/2018] [Accepted: 05/11/2018] [Indexed: 11/24/2022]  Open
120
Mourya A, Aggarwal LM, Mandal A, Shahi UP, Ram C, Asthana AK, Pradhan S. An inexpensive method of small photon field dosimetry with EBT3 radiochromic film. HEALTH AND TECHNOLOGY 2018. [DOI: 10.1007/s12553-018-0233-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
121
Monaco and film dosimetry of 3D CRT, IMRT and VMAT cases in a realistic pelvic prosthetic phantom. Radiat Phys Chem Oxf Engl 1993 2018. [DOI: 10.1016/j.radphyschem.2017.11.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
122
Khachonkham S, Dreindl R, Heilemann G, Lechner W, Fuchs H, Palmans H, Georg D, Kuess P. Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams. ACTA ACUST UNITED AC 2018;63:065007. [DOI: 10.1088/1361-6560/aab1ee] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
123
Influence of Backscatter Radiation on Cranial Bone Fixation Devices. J Craniofac Surg 2018;29:1094-1096. [PMID: 29498970 DOI: 10.1097/scs.0000000000004392] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
124
Lárraga-Gutiérrez JM, García-Garduño OA, Treviño-Palacios C, Herrera-González JA. Evaluation of a LED-based flatbed document scanner for radiochromic film dosimetry in transmission mode. Phys Med 2018;47:86-91. [DOI: 10.1016/j.ejmp.2018.02.010] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2017] [Revised: 01/28/2018] [Accepted: 02/13/2018] [Indexed: 10/17/2022]  Open
125
Dąbrowski R, Drozdyk I, Kukołowicz P. High accuracy dosimetry with small pieces of Gafchromic films. Rep Pract Oncol Radiother 2018;23:114-120. [PMID: 29681774 PMCID: PMC5908271 DOI: 10.1016/j.rpor.2018.01.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2017] [Accepted: 01/21/2018] [Indexed: 11/26/2022]  Open
126
Prasetio H, Wölfelschneider J, Ziegler M, Serpa M, Witulla B, Bert C. Dose calculation and verification of the Vero gimbal tracking treatment delivery. Phys Med Biol 2018;63:035043. [PMID: 29311415 DOI: 10.1088/1361-6560/aaa617] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
127
Accuracy and efficiency of published film dosimetry techniques using a flat-bed scanner and EBT3 film. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2018;41:117-128. [DOI: 10.1007/s13246-018-0620-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2017] [Accepted: 01/14/2018] [Indexed: 11/26/2022]
128
Aldelaijan S, Tomic N, Papaconstadopoulos P, Schneider J, Seuntjens J, Shih S, Lewis D, Devic S. Technical Note: Response time evolution of XR-QA2 GafChromic™ film models. Med Phys 2017;45:488-492. [DOI: 10.1002/mp.12689] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2017] [Revised: 09/25/2017] [Accepted: 11/10/2017] [Indexed: 11/07/2022]  Open
129
Dosimetric characterisation of anthropomorphic PRESAGE® dosimeter and EBT2 film for partial breast radiotherapy. JOURNAL OF RADIOTHERAPY IN PRACTICE 2017. [DOI: 10.1017/s1460396917000450] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
130
Experimental verification of dose enhancement effects in a lung phantom from inline magnetic fields. Radiother Oncol 2017;125:433-438. [DOI: 10.1016/j.radonc.2017.09.012] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Revised: 09/14/2017] [Accepted: 09/15/2017] [Indexed: 11/18/2022]
131
Liang LH, Tomic N, Vuong T, Aldelaijan S, Bekerat H, DeBlois F, Seuntjens J, Devic S. Physics aspects of the Papillon technique-Five decades later. Brachytherapy 2017;17:234-243. [PMID: 29102741 DOI: 10.1016/j.brachy.2017.09.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2017] [Revised: 09/26/2017] [Accepted: 09/26/2017] [Indexed: 12/15/2022]
132
Prajapati S, Cox B, Swader R, Petry G, Eliceiri KW, Jeraj R, Mackie TR. Design of an Open-Source Binary Micromultileaf Collimator for a Small Animal Microradiotherapy System. J Med Device 2017. [DOI: 10.1115/1.4038017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]  Open
133
Measurement of the influence of titanium hip prosthesis on therapeutic electron beam dose distributions in a novel pelvic phantom. Phys Med 2017;42:99-107. [DOI: 10.1016/j.ejmp.2017.09.118] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Revised: 08/24/2017] [Accepted: 09/07/2017] [Indexed: 11/17/2022]  Open
134
Cirrone GAP, Cuttone G, Raffaele L, Salamone V, Avitabile T, Privitera G, Spatola C, Amico AG, Larosa G, Leanza R, Margarone D, Milluzzo G, Patti V, Petringa G, Romano F, Russo A, Russo A, Sabini MG, Schillaci F, Scuderi V, Valastro LM. Clinical and Research Activities at the CATANA Facility of INFN-LNS: From the Conventional Hadrontherapy to the Laser-Driven Approach. Front Oncol 2017;7:223. [PMID: 28971066 PMCID: PMC5609572 DOI: 10.3389/fonc.2017.00223] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2016] [Accepted: 09/01/2017] [Indexed: 01/16/2023]  Open
135
Dose comparison between TG-43–based calculations and radiochromic film measurements of the Freiburg flap applicator used for high-dose-rate brachytherapy treatments of skin lesions. Brachytherapy 2017;16:1065-1072. [DOI: 10.1016/j.brachy.2017.06.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2017] [Revised: 06/24/2017] [Accepted: 06/26/2017] [Indexed: 11/19/2022]
136
Ade N, du Plessis FCP. Dose comparison between Gafchromic film, XiO, and Monaco treatment planning systems in a novel pelvic phantom that contains a titanium hip prosthesis. J Appl Clin Med Phys 2017;18:162-173. [PMID: 28741892 PMCID: PMC5874810 DOI: 10.1002/acm2.12141] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2016] [Revised: 06/05/2017] [Accepted: 06/09/2017] [Indexed: 11/29/2022]  Open
137
Martínez-Rovira I, González W, Brons S, Prezado Y. Carbon and oxygen minibeam radiation therapy: An experimental dosimetric evaluation. Med Phys 2017;44:4223-4229. [PMID: 28556241 DOI: 10.1002/mp.12383] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2016] [Revised: 05/03/2017] [Accepted: 05/21/2017] [Indexed: 11/06/2022]  Open
138
Isa NM, Baharin R, Majid RA, Rahman WAWA. Optical properties of conjugated polymer: review of its change mechanism for ionizing radiation sensor. POLYM ADVAN TECHNOL 2017. [DOI: 10.1002/pat.4067] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
139
Analysis of Gafchromic EBT3 film calibration irradiated with gamma rays from different systems: Gamma Knife and Cobalt-60 unit. Med Dosim 2017;42:159-168. [PMID: 28527605 DOI: 10.1016/j.meddos.2017.01.003] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2015] [Revised: 11/19/2016] [Accepted: 01/29/2017] [Indexed: 11/20/2022]
140
Callens MB, Crijns W, Depuydt T, Haustermans K, Maes F, D’Agostino E, Wevers M, Pfeiffer H, Van Den Abeele K. Modeling the dose dependence of the vis-absorption spectrum of EBT3 GafChromic™ films. Med Phys 2017;44:2532-2543. [DOI: 10.1002/mp.12246] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2016] [Revised: 02/16/2017] [Accepted: 03/14/2017] [Indexed: 11/10/2022]  Open
141
Commissioning of applicator-guided stereotactic body radiation therapy boost with high-dose-rate brachytherapy for advanced cervical cancer using radiochromic film dosimetry. Brachytherapy 2017;16:893-902. [PMID: 28457741 DOI: 10.1016/j.brachy.2017.03.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2016] [Revised: 02/21/2017] [Accepted: 03/21/2017] [Indexed: 11/21/2022]
142
Hsiao MC, Jiang SH. A Characterization Study of GafChromic EBT Film as a Two-Dimensional Dosimeter. NUCL TECHNOL 2017. [DOI: 10.13182/nt09-a9124] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
143
A study of four radiochromic films currently used for (2D) radiation dosimetry. Radiat Phys Chem Oxf Engl 1993 2017. [DOI: 10.1016/j.radphyschem.2016.12.006] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
144
Molazadeh M, Zeinali A, Robatjazi M, Shirazi A, Geraily G. Dosimetric characteristics of LinaTech DMLC H multi leaf collimator: Monte Carlo simulation and experimental study. J Appl Clin Med Phys 2017;18:113-124. [PMID: 28300380 PMCID: PMC5689964 DOI: 10.1002/acm2.12055] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2016] [Revised: 01/08/2017] [Accepted: 01/10/2017] [Indexed: 11/09/2022]  Open
145
Felix MC, Glatting G, Giordano FA, Brockmann MA, Wenz F, Fleckenstein J. Collimator optimization for small animal radiation therapy at a micro-CT. Z Med Phys 2017;27:56-64. [DOI: 10.1016/j.zemedi.2016.05.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2015] [Revised: 05/22/2016] [Accepted: 05/25/2016] [Indexed: 11/16/2022]
146
Sridharan V, Seawright JW, Antonawich FJ, Garnett M, Cao M, Singh P, Boerma M. Late Administration of a Palladium Lipoic Acid Complex (POLY-MVA) Modifies Cardiac Mitochondria but Not Functional or Structural Manifestations of Radiation-Induced Heart Disease in a Rat Model. Radiat Res 2017;187:361-366. [PMID: 28231026 DOI: 10.1667/rr14643.1] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
147
Borowicz DM, Malicki J, Mytsin G, Shipulin K. Dose distribution at the Bragg peak: Dose measurements using EBT and RTQA gafchromic film set at two positions to the central beam axis. Med Phys 2017;44:1538-1544. [PMID: 28196271 DOI: 10.1002/mp.12159] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Revised: 01/23/2017] [Accepted: 02/05/2017] [Indexed: 11/08/2022]  Open
148
Jaccard M, Petersson K, Buchillier T, Germond JF, Durán MT, Vozenin MC, Bourhis J, Bochud FO, Bailat C. High dose-per-pulse electron beam dosimetry: Usability and dose-rate independence of EBT3 Gafchromic films. Med Phys 2017;44:725-735. [PMID: 28019660 DOI: 10.1002/mp.12066] [Citation(s) in RCA: 96] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2016] [Revised: 12/02/2016] [Accepted: 12/07/2016] [Indexed: 11/09/2022]  Open
149
Cusumano D, Fumagalli ML, Ghielmetti F, Rossi L, Grossi G, Lanzarotti R, Fariselli L, De Martin E. Sum signal dosimetry: A new approach for high dose quality assurance with Gafchromic EBT3. J Appl Clin Med Phys 2017;18:181-190. [PMID: 28300373 PMCID: PMC5689947 DOI: 10.1002/acm2.12045] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2016] [Revised: 11/17/2016] [Accepted: 11/24/2016] [Indexed: 11/23/2022]  Open
150
Sakamoto Y, Koike N, Takei H, Ohno M, Miwa T, Yoshida K, Shigematsu N, Kishi K. Influence of backscatter radiation on cranial reconstruction implants. Br J Radiol 2017;90:20150537. [PMID: 27925774 PMCID: PMC5685122 DOI: 10.1259/bjr.20150537] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2015] [Revised: 11/27/2016] [Accepted: 11/30/2016] [Indexed: 11/05/2022]  Open
PrevPage 3 of 9 1234589Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA