101
|
Single cell electrophysiological alterations under dynamic loading at ultrasonic frequencies. BRAIN MULTIPHYSICS 2021. [DOI: 10.1016/j.brain.2021.100031] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
|
102
|
Estrada H, Ozbek A, Robin J, Shoham S, Razansky D. Spherical Array System for High-Precision Transcranial Ultrasound Stimulation and Optoacoustic Imaging in Rodents. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:107-115. [PMID: 32406833 PMCID: PMC7952015 DOI: 10.1109/tuffc.2020.2994877] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Ultrasound can be delivered transcranially to ablate brain tissue, open the blood-brain barrier, or affect neural activity. Transcranial focused ultrasound in small rodents is typically done with low-frequency single-element transducers, which results in unspecific targeting and impedes the concurrent use of fast neuroimaging methods. In this article, we devised a wide-angle spherical array bidirectional interface for high-resolution parallelized optoacoustic imaging and transcranial ultrasound (POTUS) delivery in the same target regions. The system operates between 3 and 9 MHz, allowing to generate and steer focal spots with widths down to [Formula: see text] across a field of view covering the entire mouse brain, while the same array is used to capture high-resolution 3-D optoacoustic data in real time. We showcase the system's versatile beam-forming capacities as well as volumetric optoacoustic imaging capabilities and discuss its potential to noninvasively monitor brain activity and various effects of ultrasound emission.
Collapse
|
103
|
Pang N, Huang X, Zhou H, Xia X, Liu X, Wang Y, Meng W, Bian T, Meng L, Xu L, Niu L. Transcranial Ultrasound Stimulation of Hypothalamus in Aging Mice. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:29-37. [PMID: 31985418 DOI: 10.1109/tuffc.2020.2968479] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The hypothalamus plays an important role in the control of aging. Transcranial ultrasound stimulation (TUS) has been reported as a noninvasive method of neuromodulation. However, the effect of TUS of the hypothalamus on aging remains unclear. Therefore, the aim of this study is to verify whether TUS of the hypothalamus could affect the behaviors of aging mice and the expression level of apoptosis factors and inflammatory cytokines. TUS was delivered to the hypothalamus of mice ( n = 44 ) for 14 days (15 min/day) at a fundamental frequency of 1 MHz, pulse repetition frequency of 1 kHz (US1) or 10 Hz (US2), duty cycle of 10%, and acoustic pressure of 0.13 MPa. The effect of TUS on aging was evaluated by the behavioral tests or Western blotting in different stages. The behavioral results showed that mice in the US2 group improved their movement and learning. In addition, there was a significant improvement in the grip strength after TUS in the second behavioral tests (Sham: 0.0351 ± 0.0020 N/g; US1: 0.0340 ± 0.0023 N/g; US2: 0.0425 ± 0.0029 N/g, p = 0.034 ). Furthermore, the level of inflammation (TNF- α : Sham: 0.69 ± 0.084; US1: 0.39 ± 0.054; US2: 0.49 ± 0.1, p = 0.021 ) and apoptosis (Bax: Sham: 0.47 ± 0.049; US1: 0.42 ± 0.054; US2: 0.18 ± 0.055, p = 0.001 ) was significantly reduced after TUS in this stage. We did not see a long-lasting effect of TUS in the third behavioral tests. In addition, we found that TUS is safe according to hematoxylin and eosin (HE) staining. In conclusion, TUS could effectively modulate the hypothalamus, which may provide a new method for controlling aging.
Collapse
|
104
|
Fomenko A, Chen KHS, Nankoo JF, Saravanamuttu J, Wang Y, El-Baba M, Xia X, Seerala SS, Hynynen K, Lozano AM, Chen R. Systematic examination of low-intensity ultrasound parameters on human motor cortex excitability and behavior. eLife 2020; 9:e54497. [PMID: 33236981 PMCID: PMC7728443 DOI: 10.7554/elife.54497] [Citation(s) in RCA: 69] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Accepted: 11/24/2020] [Indexed: 12/23/2022] Open
Abstract
Low-intensity transcranial ultrasound (TUS) can non-invasively modulate human neural activity. We investigated how different fundamental sonication parameters influence the effects of TUS on the motor cortex (M1) of 16 healthy subjects by probing cortico-cortical excitability and behavior. A low-intensity 500 kHz TUS transducer was coupled to a transcranial magnetic stimulation (TMS) coil. TMS was delivered 10 ms before the end of TUS to the left M1 hotspot of the first dorsal interosseous muscle. Varying acoustic parameters (pulse repetition frequency, duty cycle, and sonication duration) on motor-evoked potential amplitude were examined. Paired-pulse measures of cortical inhibition and facilitation, and performance on a visuomotor task was also assessed. TUS safely suppressed TMS-elicited motor cortical activity, with longer sonication durations and shorter duty cycles when delivered in a blocked paradigm. TUS increased GABAA-mediated short-interval intracortical inhibition and decreased reaction time on visuomotor task but not when controlled with TUS at near-somatosensory threshold intensity.
Collapse
Affiliation(s)
- Anton Fomenko
- Krembil Research Institute, University Health NetworkTorontoCanada
| | - Kai-Hsiang Stanley Chen
- Krembil Research Institute, University Health NetworkTorontoCanada
- Department of Neurology, National Taiwan University Hospital Hsin-Chu BranchHsin-ChuTaiwan
| | | | | | - Yanqiu Wang
- Krembil Research Institute, University Health NetworkTorontoCanada
| | - Mazen El-Baba
- Krembil Research Institute, University Health NetworkTorontoCanada
| | - Xue Xia
- Division of Neurology, Department of Medicine, University of TorontoTorontoCanada
| | | | | | - Andres M Lozano
- Krembil Research Institute, University Health NetworkTorontoCanada
- Division of Neurosurgery, Department of Surgery, Toronto Western Hospital, University of TorontoTorontoCanada
| | - Robert Chen
- Krembil Research Institute, University Health NetworkTorontoCanada
- Division of Neurology, Department of Medicine, University of TorontoTorontoCanada
| |
Collapse
|
105
|
Lee SA, Kamimura HAS, Burgess MT, Konofagou EE. Displacement Imaging for Focused Ultrasound Peripheral Nerve Neuromodulation. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:3391-3402. [PMID: 32406828 PMCID: PMC7717066 DOI: 10.1109/tmi.2020.2992498] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Focused ultrasound (FUS) is an emerging technique for neuromodulation due to its noninvasive application and high depth penetration. Recent studies have reported success in modulation of brain circuits, peripheral nerves, ion channels, and organ structures. In particular, neuromodulation of peripheral nerves and the underlying mechanisms remain comparatively unexplored in vivo. Lack of methodologies for FUS targeting and monitoring impede further research in in vivo studies. Thus, we developed a method that non-invasively measures nerve engagement, via tissue displacement, during FUS neuromodulation of in vivo nerves using simultaneous high frame-rate ultrasound imaging. Using this system, we can validate, in real-time, FUS targeting of the nerve and characterize subsequent compound muscle action potentials (CMAPs) elicited from sciatic nerve activation in mice using 0.5 to 5 ms pulse durations and 22 - 28 MPa peak positive stimulus pressures at 4 MHz. Interestingly, successful motor excitation from FUS neuromodulation required a minimum interframe nerve displacement of 18 μm without any displacement incurred at the skin or muscle levels. Moreover, CMAPs detected in mice monotonically increased with interframe nerve displacements within the range of 18 to 300 μm . Thus, correlation between nerve displacement and motor activation constitutes strong evidence FUS neuromodulation is driven by a mechanical effect given that tissue deflection is a result of highly focused acoustic radiation force.
Collapse
|
106
|
Zhang J, Zhou H, Yang J, Jia J, Niu L, Sun Z, Shi D, Meng L, Qiu W, Wang X, Zheng H, Wang G. Low-intensity pulsed ultrasound ameliorates depression-like behaviors in a rat model of chronic unpredictable stress. CNS Neurosci Ther 2020; 27:233-243. [PMID: 33112507 PMCID: PMC7816209 DOI: 10.1111/cns.13463] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2020] [Revised: 09/05/2020] [Accepted: 09/24/2020] [Indexed: 12/28/2022] Open
Abstract
Introduction There is an unmet need for better nonpharmaceutical treatments for depression. Low‐intensity pulsed ultrasound (LIPUS) is a novel type of neuromodulation that could be helpful for depressed patients. Objective The goal of this study was to investigate the feasibility and potential mechanisms of LIPUS in the treatment of depression. Methods Chronic unpredictable stress (CUS) was used to generate rats with depression‐like features that were treated with four weeks of LIPUS stimulation of the ventromedial prefrontal cortex. Depression‐like behaviors were assessed with the sucrose preference, forced swim, and open field tests. BDNF/mTORC1 signaling was examined by Western blot to investigate this potential molecular mechanism. The safety of LIPUS was evaluated using hematoxylin‐eosin and Nissl staining. Results Four weeks of LIPUS stimulation significantly increased sucrose preference and reduced forced swim immobility time in CUS rats. LIPUS also partially reversed the molecular effects of CUS that included decreased levels of BDNF, phosphorylated tyrosine receptor kinase B (TrkB), extracellular signal‐regulated kinase (ERK), mammalian target of rapamycin complex 1 (mTORC1), and S6 kinase (S6K). Moreover, histological staining revealed no gross tissue damage. Conclusions Chronic LIPUS stimulation can effectively and safely improve depression‐like behaviors in CUS rats. The underlying mechanisms may be related to enhancement of BDNF/ERK/mTORC1 signaling pathways in the prefrontal cortex (PFC). LIPUS is a promising noninvasive neuromodulation tool that merits further study as a potential treatment for depression.
Collapse
Affiliation(s)
- Jinniu Zhang
- The National Clinical Research Center for Mental Disorders & Beijing Key Laboratory of Mental Disorders, Beijing Anding Hospital, Capital Medical University, Beijing, China
| | - Hui Zhou
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Jian Yang
- The National Clinical Research Center for Mental Disorders & Beijing Key Laboratory of Mental Disorders, Beijing Anding Hospital, Capital Medical University, Beijing, China.,Key Laboratory for the Neurodegenerative Disorders of the Chinese Ministry of Education, Department of Physiology, Capital Medical University, Beijing, China
| | - Jun Jia
- Advanced Innovation Center for Human Brain Protection, Capital Medical University, Beijing, China
| | - Lili Niu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Zuoli Sun
- The National Clinical Research Center for Mental Disorders & Beijing Key Laboratory of Mental Disorders, Beijing Anding Hospital, Capital Medical University, Beijing, China
| | - Dandan Shi
- The National Clinical Research Center for Mental Disorders & Beijing Key Laboratory of Mental Disorders, Beijing Anding Hospital, Capital Medical University, Beijing, China
| | - Long Meng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Weibao Qiu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Xiaomin Wang
- Advanced Innovation Center for Human Brain Protection, Capital Medical University, Beijing, China
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Gang Wang
- The National Clinical Research Center for Mental Disorders & Beijing Key Laboratory of Mental Disorders, Beijing Anding Hospital, Capital Medical University, Beijing, China.,Key Laboratory for the Neurodegenerative Disorders of the Chinese Ministry of Education, Department of Physiology, Capital Medical University, Beijing, China
| |
Collapse
|
107
|
Rabut C, Yoo S, Hurt RC, Jin Z, Li H, Guo H, Ling B, Shapiro MG. Ultrasound Technologies for Imaging and Modulating Neural Activity. Neuron 2020; 108:93-110. [PMID: 33058769 PMCID: PMC7577369 DOI: 10.1016/j.neuron.2020.09.003] [Citation(s) in RCA: 111] [Impact Index Per Article: 27.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 08/25/2020] [Accepted: 09/01/2020] [Indexed: 02/06/2023]
Abstract
Visualizing and perturbing neural activity on a brain-wide scale in model animals and humans is a major goal of neuroscience technology development. Established electrical and optical techniques typically break down at this scale due to inherent physical limitations. In contrast, ultrasound readily permeates the brain, and in some cases the skull, and interacts with tissue with a fundamental resolution on the order of 100 μm and 1 ms. This basic ability has motivated major efforts to harness ultrasound as a modality for large-scale brain imaging and modulation. These efforts have resulted in already-useful neuroscience tools, including high-resolution hemodynamic functional imaging, focused ultrasound neuromodulation, and local drug delivery. Furthermore, recent breakthroughs promise to connect ultrasound to neurons at the genetic level for biomolecular imaging and sonogenetic control. In this article, we review the state of the art and ongoing developments in ultrasonic neurotechnology, building from fundamental principles to current utility, open questions, and future potential.
Collapse
Affiliation(s)
- Claire Rabut
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Sangjin Yoo
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Robert C Hurt
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Zhiyang Jin
- Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA
| | - Hongyi Li
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Hongsun Guo
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Bill Ling
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Mikhail G Shapiro
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA, USA.
| |
Collapse
|
108
|
Tarnaud T, Joseph W, Schoeters R, Martens L, Tanghe E. SECONIC: Towards multi-compartmental models for ultrasonic brain stimulation by intramembrane cavitation. J Neural Eng 2020; 17:056010. [PMID: 33043898 DOI: 10.1088/1741-2552/abb73d] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
OBJECTIVE To design a computationally efficient model for ultrasonic neuromodulation (UNMOD) of morphologically realistic multi-compartmental neurons based on intramembrane cavitation. APPROACH A Spatially Extended Neuronal Intramembrane Cavitation model that accurately predicts observed fast Charge Oscillations (SECONIC) is designed. A regular spiking cortical Hodgkin-Huxley type nanoscale neuron model of the bilayer sonophore and surrounding proteins is used. The accuracy and computational efficiency of SECONIC is compared with the Neuronal Intramembrane Cavitation Excitation (NICE) and multiScale Optimized model of Neuronal Intramembrane Cavitation (SONIC). MAIN RESULTS Membrane charge redistribution between different compartments should be taken into account via fourier series analysis in an accurate multi-compartmental UNMOD-model. Approximating charge and voltage traces with the harmonic term and first two overtones results in reasonable goodness-of-fit, except for high ultrasonic pressure (adjusted R-squared ≥0.61). Taking into account the first eight overtones results in a very good fourier series fit (adjusted R-squared ≥0.96) up to 600 kPa. Next, the dependency of effective voltage and rate parameters on charge oscillations is investigated. The two-tone SECONIC-model is one to two orders of magnitude faster than the NICE-model and demonstrates accurate results for ultrasonic pressure up to 100 kPa. SIGNIFICANCE Up to now, the underlying mechanism of UNMOD is not well understood. Here, the extension of the bilayer sonophore model to spatially extended neurons via the design of a multi-compartmental UNMOD-model, will result in more detailed predictions that can be used to validate or falsify this tentative mechanism. Furthermore, a multi-compartmental model for UNMOD is required for neural engineering studies that couple finite difference time domain simulations with neuronal models. Here, we propose the SECONIC-model, extending the SONIC-model by taking into account charge redistribution between compartments.
Collapse
Affiliation(s)
- Thomas Tarnaud
- Department of Information Technology (INTEC-WAVES/IMEC), Ghent University/IMEC, Technologypark 126, 9052 Zwijnaarde, Belgium. Author to whom any correspondence should be addressed
| | | | | | | | | |
Collapse
|
109
|
Manuel TJ, Kusunose J, Zhan X, Lv X, Kang E, Yang A, Xiang Z, Caskey CF. Ultrasound neuromodulation depends on pulse repetition frequency and can modulate inhibitory effects of TTX. Sci Rep 2020; 10:15347. [PMID: 32948791 PMCID: PMC7501284 DOI: 10.1038/s41598-020-72189-y] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Accepted: 08/18/2020] [Indexed: 12/24/2022] Open
Abstract
Ultrasound is gaining traction as a neuromodulation method due to its ability to remotely and non-invasively modulate neuronal activity with millimeter precision. However, there is little consensus about optimal ultrasound parameters required to elicit neuromodulation and how specific parameters drive mechanisms that underlie ultrasound neuromodulation. We address these questions in this work by performing a study to determine effective ultrasound parameters in a transgenic mouse brain slice model that enables calcium imaging as a quantitative readout of neuronal activity for ultrasound neuromodulation. We report that (1) calcium signaling increases with the application of ultrasound; (2) the neuronal response rate to ultrasound is dependent on pulse repetition frequency (PRF); and (3) ultrasound can reversibly alter the inhibitory effects of tetrodotoxin (TTX) in pharmacological studies. This study offers mechanistic insight into the PRF dependence of ultrasound neuromodulation and the nature of ultrasound/ion channel interaction.
Collapse
Affiliation(s)
- Thomas J Manuel
- Vanderbilt University Institute of Imaging Science, Nashville, TN, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Jiro Kusunose
- Vanderbilt University Institute of Imaging Science, Nashville, TN, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Xiaoyan Zhan
- Department of Pharmacology, Vanderbilt University, Nashville, TN, USA
- Vanderbilt Center for Neuroscience Drug Discovery, Vanderbilt University, Nashville, TN, USA
| | - Xiaohui Lv
- Department of Pharmacology, Vanderbilt University, Nashville, TN, USA
- Vanderbilt Center for Neuroscience Drug Discovery, Vanderbilt University, Nashville, TN, USA
| | - Ellison Kang
- Department of Pharmacology, Vanderbilt University, Nashville, TN, USA
- Vanderbilt Center for Neuroscience Drug Discovery, Vanderbilt University, Nashville, TN, USA
| | - Aaron Yang
- Department of Pharmacology, Vanderbilt University, Nashville, TN, USA
- Vanderbilt Center for Neuroscience Drug Discovery, Vanderbilt University, Nashville, TN, USA
| | - Zixiu Xiang
- Department of Pharmacology, Vanderbilt University, Nashville, TN, USA.
- Vanderbilt Center for Neuroscience Drug Discovery, Vanderbilt University, Nashville, TN, USA.
| | - Charles F Caskey
- Vanderbilt University Institute of Imaging Science, Nashville, TN, USA.
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA.
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA.
| |
Collapse
|
110
|
Yu K, Niu X, He B. Neuromodulation Management of Chronic Neuropathic Pain in The Central Nervous system. ADVANCED FUNCTIONAL MATERIALS 2020; 30:1908999. [PMID: 34335132 PMCID: PMC8323399 DOI: 10.1002/adfm.201908999] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Indexed: 05/05/2023]
Abstract
Neuromodulation is becoming one of the clinical tools for treating chronic neuropathic pain by transmitting controlled physical energy to the pre-identified neural targets in the central nervous system. Its nature of drug-free, non-addictive and improved targeting have attracted increasing attention among neuroscience research and clinical practices. This article provides a brief overview of the neuropathic pain and pharmacological routines for treatment, summarizes both the invasive and non-invasive neuromodulation modalities for pain management, and highlights an emerging brain stimulation technology, transcranial focused ultrasound (tFUS) with a focus on ultrasound transducer devices and the achieved neuromodulation effects and applications on pain management. Practical considerations of spatial guidance for tFUS are discussed for clinical applications. The safety of transcranial ultrasound neuromodulation and its future prospectives on pain management are also discussed.
Collapse
Affiliation(s)
| | | | - Bin He
- Department of Biomedical Engineering, Carnegie Mellon University
| |
Collapse
|
111
|
Todd N, McDannold N, Borsook D. Targeted manipulation of pain neural networks: The potential of focused ultrasound for treatment of chronic pain. Neurosci Biobehav Rev 2020; 115:238-250. [PMID: 32534900 PMCID: PMC7483565 DOI: 10.1016/j.neubiorev.2020.06.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Revised: 04/24/2020] [Accepted: 06/04/2020] [Indexed: 12/29/2022]
Abstract
Focused ultrasound (FUS) is a promising technology for facilitating treatment of brain diseases including chronic pain. Focused ultrasound is a unique modality for delivering therapeutic levels of energy into the body, including the central nervous system (CNS). It is non-invasive and can target spatially localized effects through the intact skull to cortical or subcortical regions of the brain. FUS can achieve three different mechanisms of action in the brain that are relevant for chronic pain treatment: (1) localized thermal ablation of neural tissue; (2) localized and transient disruption of the blood-brain barrier for targeted drug delivery to CNS structures; and (3) inhibition or stimulation of neuronal activity in targeted regions. This review provides an in-depth look at the technology of FUS with emphasis placed on applications to CNS-based treatments of chronic pain. While still in the early stages of clinical translation and with some technical challenges remaining, we suggest that FUS has great potential as a novel approach for manipulating CNS networks involved in pain treatment.
Collapse
Affiliation(s)
- Nick Todd
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, United States; Center for Pain and the Brain, 1 Autumn Street, Boston Children's Hospital, Boston, MA, 02115, United States.
| | - Nathan McDannold
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, United States
| | - David Borsook
- Center for Pain and the Brain, 1 Autumn Street, Boston Children's Hospital, Boston, MA, 02115, United States; Department of Anesthesia, Perioperative, and Pain Medicine, Boston Children's Hospital, Harvard Medical School, Boston, MA, 02115, United States
| |
Collapse
|
112
|
Wang S, Meng W, Ren Z, Li B, Zhu T, Chen H, Wang Z, He B, Zhao D, Jiang H. Ultrasonic Neuromodulation and Sonogenetics: A New Era for Neural Modulation. Front Physiol 2020; 11:787. [PMID: 32765294 PMCID: PMC7378787 DOI: 10.3389/fphys.2020.00787] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Accepted: 06/15/2020] [Indexed: 12/19/2022] Open
Abstract
Non-invasive ultrasonic neural modulation (UNM), a non-invasive technique with enhanced spatial focus compared to conventional electrical neural modulation, has attracted much attention in recent decades and might become the mainstream regimen for neurological disorders. However, as ultrasonic bioeffects and its adjustments are still unclear, it remains difficult to be extensively applied for therapeutic purpose, much less in the setting of human skull. Hence to comprehensively understand the way ultrasound exerts bioeffects, we explored UNM from a basic perspective by illustrating the parameter settings and the underlying mechanisms. In addition, although the spatial resolution and precision of UNM are considerable, UNM is relatively non-specific to tissue or cell type and shows very low specificity at the molecular level. Surprisingly, Ibsen et al. (2015) first proposed the concept of sonogenetics, which combined UNM and mechanosensitive (MS) channel protein. This emerging approach is a valuable improvement, as it may markedly increase the precision and spatial resolution of UNM. It seemed to be an inspiring tool with high accuracy and specificity, however, little information about sonogenetics is currently available. Thus, in order to provide an overview of sonogenetics and prompt the researches on UNM, we summarized the potential mechanisms from a molecular level.
Collapse
Affiliation(s)
- Songyun Wang
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Weilun Meng
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China.,Medical Department, Nanjing Medical University, Nanjing, China
| | - Zhongyuan Ren
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China.,Medical Department, Soochow University Medical College, Suzhou, China
| | - Binxun Li
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Tongjian Zhu
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Hui Chen
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Zhen Wang
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Bo He
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Dongdong Zhao
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China
| | - Hong Jiang
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, China
| |
Collapse
|
113
|
Xu T, Lu X, Peng D, Wang G, Chen C, Liu W, Wu W, Mason TJ. Ultrasonic stimulation of the brain to enhance the release of dopamine - A potential novel treatment for Parkinson's disease. ULTRASONICS SONOCHEMISTRY 2020; 63:104955. [PMID: 31945561 DOI: 10.1016/j.ultsonch.2019.104955] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Revised: 12/15/2019] [Accepted: 12/30/2019] [Indexed: 05/14/2023]
Abstract
Parkinson's disease (PD) is characterized by the decrease of dopamine (DA) production and release in the substantia nigra and striatum regions of the brain. Transcranial ultrasound has been exploited recently for neuromodulation of the brain in a number of fields. We have stimulated DA release in PC12 cells using low-intensity continuous ultrasound (0.1 W/cm2 - 0.3 W/cm2, 1 MHz), 12 h after exposure at 0.2 W/cm2, 40 s, the amount of DA content eventually increased 78.5% (p = 0.004). After 10-day ultrasonic treatment (0.3 W/cm2, 5 min/d), the DA content in the striatum of PD mice model restored to 81.07% of the control (vs 43.42% in the untreated PD mice model). In addition to this the locomotion activity was restored to the normal level after treatment. We suggest that the low intensity ultrasound-induced DA release can be attributed to a combination of neuron regeneration and improved membrane permeability produced by the mechanical force of ultrasound. Our study indicates that the application of transcranial ultrasound applied below FDA limits, could provide a candidate for relatively safe and noninvasive PD therapy through an amplification of DA levels and the stimulation of dopaminergic neuron regeneration without contrast agents.
Collapse
Affiliation(s)
- Tian Xu
- Key Laboratory of Environment Medicine and Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China; School of Nursing, Taihu University of Wuxi, Wuxi 214000, China
| | - Xiaoxiao Lu
- Key Laboratory of Environment Medicine and Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China
| | - Danhong Peng
- Key Laboratory of Environment Medicine and Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China
| | - Gongdao Wang
- Key Laboratory of Environment Medicine and Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China
| | - Chen Chen
- Key Laboratory of Environment Medicine and Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China
| | - Wen Liu
- Key Laboratory of Environment Medicine and Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China
| | - Wei Wu
- Key Laboratory of Environment Medicine and Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China.
| | - Timothy J Mason
- Centre for Research in the Built and Natural Environment, Coventry CV1 5FB, UK.
| |
Collapse
|
114
|
Lin Z, Meng L, Zou J, Zhou W, Huang X, Xue S, Bian T, Yuan T, Niu L, Guo Y, Zheng H. Non-invasive ultrasonic neuromodulation of neuronal excitability for treatment of epilepsy. Theranostics 2020; 10:5514-5526. [PMID: 32373225 PMCID: PMC7196311 DOI: 10.7150/thno.40520] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2019] [Accepted: 01/10/2020] [Indexed: 12/19/2022] Open
Abstract
Non-invasive low-intensity pulsed ultrasound has been employed for direct neuro-modulation. However, its range and effectiveness for different neurological disorders have not been fully elucidated. Methods: We used multiple approaches of electrophysiology, immunohistochemistry, and behavioral tests as potential epilepsy treatments in non-human primate model of epilepsy and human epileptic tissues. Low-intensity pulsed ultrasound with a frequency of 750 kHz and acoustic pressure of 0.35 MPa (the spatial peak pulse average intensity, ISPPA = 2.02 W/cm2) were delivered to the epileptogenic foci in five penicillin-induced epileptic monkey models. An ultrasound neuro-modulation system with a frequency of 28 MHz and acoustic pressure of 0.13 MPa (ISPPA = 465 mW/cm2) compatible with patch-clamp systems was used to stimulate the brain slices prepared from fifteen patients with epilepsy. Results: After 30 min of low-intensity pulsed ultrasound treatment, total seizure count for 16 hours (sham group: 107.7 ± 1.2, ultrasound group: 66.0 ± 7.9, P < 0.01) and seizure frequency per hour (sham group: 15.6 ± 1.2, ultrasound group: 9.6 ± 1.5, P < 0.05) were significantly reduced. The therapeutic efficacy and underlying potential mechanism of low-intensity pulsed ultrasound treatment were studied in biopsy specimens from epileptic patients in vitro. Ultrasound stimulation could inhibit epileptiform activities with an efficiency exceeding 65%, potentially due to adjusting the balance of excitatory-inhibitory (E/I) synaptic inputs by the increased activity of local inhibitory neurons. Conclusion: Herein, we demonstrated for the first time that low-intensity pulsed ultrasound improves electrophysiological activities and behavioral outcomes in a non-human primate model of epilepsy and suppresses epileptiform activities of neurons from human epileptic slices. The study provides evidence for the potential clinical use of non-invasive low-intensity pulsed ultrasound stimulation for epilepsy treatment.
Collapse
|
115
|
Legon W, Adams S, Bansal P, Patel PD, Hobbs L, Ai L, Mueller JK, Meekins G, Gillick BT. A retrospective qualitative report of symptoms and safety from transcranial focused ultrasound for neuromodulation in humans. Sci Rep 2020; 10:5573. [PMID: 32221350 PMCID: PMC7101402 DOI: 10.1038/s41598-020-62265-8] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2019] [Accepted: 03/04/2020] [Indexed: 02/08/2023] Open
Abstract
Low intensity transcranial focused ultrasound (LIFU) is a promising method of non-invasive neuromodulation that uses mechanical energy to affect neuronal excitability. LIFU confers high spatial resolution and adjustable focal lengths for precise neuromodulation of discrete regions in the human brain. Before the full potential of low intensity ultrasound for research and clinical application can be investigated, data on the safety of this technique is indicated. Here, we provide an evaluation of the safety of LIFU for human neuromodulation through participant report and neurological assessment with a comparison of symptomology to other forms of non-invasive brain stimulation. Participants (N = 120) that were enrolled in one of seven human ultrasound neuromodulation studies in one laboratory at the University of Minnesota (2015–2017) were queried to complete a follow-up Participant Report of Symptoms questionnaire assessing their self-reported experience and tolerance to participation in LIFU research (Isppa 11.56–17.12 W/cm2) and the perceived relation of symptoms to LIFU. A total of 64/120 participant (53%) responded to follow-up requests to complete the Participant Report of Symptoms questionnaire. None of the participants experienced serious adverse effects. From the post-hoc assessment of safety using the questionnaire, 7/64 reported mild to moderate symptoms, that were perceived as ‘possibly’ or ‘probably’ related to participation in LIFU experiments. These reports included neck pain, problems with attention, muscle twitches and anxiety. The most common unrelated symptoms included sleepiness and neck pain. There were initial transient reports of mild neck pain, scalp tingling and headache that were extinguished upon follow-up. No new symptoms were reported upon follow up out to 1 month. The profile and incidence of symptoms looks to be similar to other forms of non-invasive brain stimulation.
Collapse
Affiliation(s)
- Wynn Legon
- Division of Physical Therapy and Rehabilitation Science, Department of Rehabilitation Medicine, School of Medicine, University of Minnesota, MN, Minneapolis, USA. .,Department of Neurological Surgery, School of Medicine, University of Virginia, VA, Charlottesville, USA.
| | - Sarah Adams
- Department of Neurological Surgery, School of Medicine, University of Virginia, VA, Charlottesville, USA
| | - Priya Bansal
- Division of Physical Therapy and Rehabilitation Science, Department of Rehabilitation Medicine, School of Medicine, University of Minnesota, MN, Minneapolis, USA
| | - Parantap D Patel
- School of Medicine, University of Virginia, VA, Charlottesville, USA
| | - Landon Hobbs
- School of Medicine, University of Virginia, VA, Charlottesville, USA
| | - Leo Ai
- Division of Physical Therapy and Rehabilitation Science, Department of Rehabilitation Medicine, School of Medicine, University of Minnesota, MN, Minneapolis, USA
| | - Jerel K Mueller
- Division of Physical Therapy and Rehabilitation Science, Department of Rehabilitation Medicine, School of Medicine, University of Minnesota, MN, Minneapolis, USA
| | - Gregg Meekins
- Department of Neurology, School of Medicine, University of Minnesota, MN, Minneapolis, USA
| | - Bernadette T Gillick
- Division of Physical Therapy and Rehabilitation Science, Department of Rehabilitation Medicine, School of Medicine, University of Minnesota, MN, Minneapolis, USA
| |
Collapse
|
116
|
Optoacoustic brain stimulation at submillimeter spatial precision. Nat Commun 2020; 11:881. [PMID: 32060282 PMCID: PMC7021819 DOI: 10.1038/s41467-020-14706-1] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Accepted: 01/17/2020] [Indexed: 02/08/2023] Open
Abstract
Low-intensity ultrasound is an emerging modality for neuromodulation. Yet, transcranial neuromodulation using low-frequency piezo-based transducers offers poor spatial confinement of excitation volume, often bigger than a few millimeters in diameter. In addition, the bulky size limits their implementation in a wearable setting and prevents integration with other experimental modalities. Here, we report spatially confined optoacoustic neural stimulation through a miniaturized Fiber-Optoacoustic Converter (FOC). The FOC has a diameter of 600 μm and generates omnidirectional ultrasound wave locally at the fiber tip through the optoacoustic effect. We show that the acoustic wave generated by FOC can directly activate individual cultured neurons and generate intracellular Ca2+ transients. The FOC activates neurons within a radius of 500 μm around the fiber tip, delivering superior spatial resolution over conventional piezo-based low-frequency transducers. Finally, we demonstrate direct and spatially confined neural stimulation of mouse brain and modulation of motor activity in vivo. Low-intensity ultrasound can be used for neuromodulation in vivo, but it has poor spatial confinement and can result in unwanted cochlear pathway activation. Here the authors use the optoacoustic effect to generate spatially confined ultrasound waves to activate neurons within a 500 μm radius in the mouse brain.
Collapse
|
117
|
Yuan Y, Wang Z, Liu M, Shoham S. Cortical hemodynamic responses induced by low-intensity transcranial ultrasound stimulation of mouse cortex. Neuroimage 2020; 211:116597. [PMID: 32018004 DOI: 10.1016/j.neuroimage.2020.116597] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Revised: 12/28/2019] [Accepted: 01/31/2020] [Indexed: 10/25/2022] Open
Abstract
Ultrasound-mediated neuromodulation is emerging as a key technology for targeted noninvasive brain stimulation, but key insights into its effects and dose-response characteristics are still missing. The purpose of this study is to systematically evaluate the effect of low-intensity transcranial ultrasound stimulation (TUS) on complementary aspects of cerebral hemodynamic. We simultaneously record the EMG signal, local field potential (LFP) and cortical blood flow (CBF) using electrophysiological recording and laser speckle contrast imaging under ultrasound stimulation to simultaneously monitor motor responses, neural activities and hemodynamic changes during the application of low-intensity TUS in mouse motor cortex, using excitation pulses which caused whisker and tail movement. Our experimental results demonstrate interdependent TUS-induced motor, neural activity and hemodynamic responses that peak approximately 0.55s, 1.05s and 2.5s after TUS onset, respectively, and show a linear coupling relationship between their respective varying response amplitudes to repeated stimuli. We also found monotonic dose-response parametric relations of the CBF peak value increase as a function of stimulation intensity and duration, while stimulus duty-cycle had only a weak effect on peak responses. These findings demonstrate that TUS induces a change in cortical hemodynamics and LSCI provide a high temporal resolution view of these changes.
Collapse
Affiliation(s)
- Yi Yuan
- Institute of Electrical Engineering, Yanshan University, Qinhuangdao, 066004, China; Departments of Ophthalmology, Departments of Neuroscience and Physiology, NYU Langone Health, New York, 10016, USA.
| | - Zhijie Wang
- Institute of Electrical Engineering, Yanshan University, Qinhuangdao, 066004, China
| | - Mengyang Liu
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, 1090, Austria
| | - Shy Shoham
- Departments of Ophthalmology, Departments of Neuroscience and Physiology, NYU Langone Health, New York, 10016, USA.
| |
Collapse
|
118
|
Baek H, Sariev A, Kim MJ, Lee H, Kim J, Kim H. A neuroprotective brain stimulation for vulnerable cerebellar Purkinje cell after ischemic stroke: a study with low-intensity focused ultrasound. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2019; 2018:4744-4747. [PMID: 30441409 DOI: 10.1109/embc.2018.8513138] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The role of established contralateral cerebrocerebellar connections on cerebellar injury during stroke has been increasingly revealed in recent years. An extensive number of studies have investigated alteration in inter-hemispheric correlation in order to find brain regions whose responses are specific to restore functional loss and enhance adaptive neural plasticity after stroke. Although, several non-invasive brain stimulation studies have proven their efficacy in the treatment of stroke recovery, finding more effective brain regions that responsible for stroke rehabilitation as well as optimizing neural stimulation protocol are the main goals of further investigations. In this study, the lateral cerebellar nucleus (LCN) was exposed to Low-Intensity Focused Ultrasound (LIFU) to reduce the cerebellar damage resulting from crossed cerebellar diaschisis (CCD) phenomenon after cerebral ischemia. A mouse brain ischemia was induced by middle cerebral artery occlusion (MCAO). A level of decrease in Purkinje cell (PC) number and a quantity of myeloperoxidase (MPO) positive neutrophils in the cerebral cortex were compared between stroke and stroke+LIFU groups after MCAO. In stroke+LIFU group, the increased ipsilateral water content due to tissue swelling was observed, showing an attenuation of brain edema. Prominently, the reduction of the neuroimmune reactivity at the infarct core and the peri-infarct regions, and the increased rate of survival among PCs clearly demonstrated primary evidence of neuroprotective effect induced by LIFU-mediated cerebellar modulation.
Collapse
|
119
|
Yoon K, Lee W, Lee JE, Xu L, Croce P, Foley L, Yoo SS. Effects of sonication parameters on transcranial focused ultrasound brain stimulation in an ovine model. PLoS One 2019; 14:e0224311. [PMID: 31648261 PMCID: PMC6812789 DOI: 10.1371/journal.pone.0224311] [Citation(s) in RCA: 69] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Accepted: 10/10/2019] [Indexed: 01/01/2023] Open
Abstract
Low-intensity focused ultrasound (FUS) has significant potential as a non-invasive brain stimulation modality and novel technique for functional brain mapping, particularly with its advantage of greater spatial selectivity and depth penetration compared to existing non-invasive brain stimulation techniques. As previous studies, primarily carried out in small animals, have demonstrated that sonication parameters affect the stimulation efficiency, further investigation in large animals is necessary to translate this technique into clinical practice. In the present study, we examined the effects of sonication parameters on the transient modification of excitability of cortical and thalamic areas in an ovine model. Guided by anatomical and functional neuroimaging data specific to each animal, 250 kHz FUS was transcranially applied to the primary sensorimotor area associated with the right hind limb and its thalamic projection in sheep (n = 10) across multiple sessions using various combinations of sonication parameters. The degree of effect from FUS was assessed through electrophysiological responses, through analysis of electromyogram and electroencephalographic somatosensory evoked potentials for evaluation of excitatory and suppressive effects, respectively. We found that the modulatory effects were transient and reversible, with specific sonication parameters outperforming others in modulating regional brain activity. Magnetic resonance imaging and histological analysis conducted at different time points after the final sonication session, as well as behavioral observations, showed that repeated exposure to FUS did not damage the underlying brain tissue. Our results suggest that FUS-mediated, non-invasive, region-specific bimodal neuromodulation can be safely achieved in an ovine model, indicating its potential for translation into human studies.
Collapse
Affiliation(s)
- Kyungho Yoon
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Wonhye Lee
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Ji Eun Lee
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Linda Xu
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Phillip Croce
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Lori Foley
- Translational Discovery Laboratory, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| |
Collapse
|
120
|
Burks SR, Lorsung RM, Nagle ME, Tu TW, Frank JA. Focused ultrasound activates voltage-gated calcium channels through depolarizing TRPC1 sodium currents in kidney and skeletal muscle. Theranostics 2019; 9:5517-5531. [PMID: 31534500 PMCID: PMC6735402 DOI: 10.7150/thno.33876] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Accepted: 05/09/2019] [Indexed: 12/26/2022] Open
Abstract
Pulsed focused ultrasound (pFUS) technology is being developed for clinical neuro/immune modulation and regenerative medicine. Biological signal transduction of pFUS forces can require mechanosensitive or voltage-gated plasma membrane ion channels. Previous studies suggested pFUS is capable of activating either channel type, but their mechanistic relationship remains ambiguous. We demonstrated pFUS bioeffects increased mesenchymal stem cell tropism (MSC) by altering molecular microenvironments through cyclooxygenase-2 (COX2)-dependent pathways. This study explored specific relationships between mechanosensitive and voltage-gated Ca2+ channels (VGCC) to initiate pFUS bioeffects that increase stem cell tropism. Methods: Murine kidneys and hamstring were given pFUS (1.15 or 1.125 MHz; 4MPa peak rarefactional pressure) under ultrasound or magnetic resonance imaging guidance. Cavitation and tissue displacement were measure by hydrophone and ultrasound radiofrequency data, respectively. Elastic modeling was performed from displacement measurements. COX2 expression and MSC tropism were evaluated in the presence of pharmacological ion channel inhibitors or in transient-receptor-potential-channel-1 (TRPC1)-deficient mice. Immunohistochemistry and co-immunoprecipitation examined physical channel relationships. Fluorescent ionophore imaging of cultured C2C12 muscle cells or TCMK1 kidney cells probed physiological interactions. Results: pFUS induced tissue deformations resulting in kPa-scale forces suggesting mechanical activation of pFUS-induced bioeffects. Inhibiting VGCC or TRPC1 in vivo blocked pFUS-induced COX2 upregulation and MSC tropism to kidneys and muscle. A TRPC1/VGCC complex was observed in plasma membranes. VGCC or TRPC1 suppression blocked pFUS-induced Ca2+ transients in TCMK1 and C2C12 cells. Additionally, Ca2+ transients were blocked by reducing transmembrane Na+ potentials and observed Na+ transients were diminished by genetic TRPC1 suppression. Conclusion: This study suggests that pFUS acoustic radiation forces mechanically activate a Na+-containing TRPC1 current upstream of VGCC rather than directly opening VGCC. The electrogenic function of TRPC1 provides potential mechanistic insight into other pFUS techniques for physiological modulation and optimization strategies for clinical implementation.
Collapse
|
121
|
Radiation Force as a Physical Mechanism for Ultrasonic Neurostimulation of the Ex Vivo Retina. J Neurosci 2019; 39:6251-6264. [PMID: 31196935 DOI: 10.1523/jneurosci.2394-18.2019] [Citation(s) in RCA: 69] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Revised: 05/23/2019] [Accepted: 05/30/2019] [Indexed: 12/23/2022] Open
Abstract
Focused ultrasound has been shown to be effective at stimulating neurons in many animal models, both in vivo and ex vivo Ultrasonic neuromodulation is the only noninvasive method of stimulation that could reach deep in the brain with high spatial-temporal resolution, and thus has potential for use in clinical applications and basic studies of the nervous system. Understanding the physical mechanism by which energy in a high acoustic frequency wave is delivered to stimulate neurons will be important to optimize this technology. We imaged the isolated salamander retina of either sex during ultrasonic stimuli that drive ganglion cell activity and observed micron scale displacements, consistent with radiation force, the nonlinear delivery of momentum by a propagating wave. We recorded ganglion cell spiking activity and changed the acoustic carrier frequency across a broad range (0.5-43 MHz), finding that increased stimulation occurs at higher acoustic frequencies, ruling out cavitation as an alternative possible mechanism. A quantitative radiation force model can explain retinal responses and could potentially explain previous in vivo results in the mouse, suggesting a new hypothesis to be tested in vivo Finally, we found that neural activity was strongly modulated by the distance between the transducer and the electrode array showing the influence of standing waves on the response. We conclude that radiation force is the dominant physical mechanism underlying ultrasonic neurostimulation in the ex vivo retina and propose that the control of standing waves is a new potential method to modulate these effects.SIGNIFICANCE STATEMENT Ultrasonic neurostimulation is a promising noninvasive technology that has potential for both basic research and clinical applications. The mechanisms of ultrasonic neurostimulation are unknown, making it difficult to optimize in any given application. We studied the physical mechanism by which ultrasound is converted into an effective energy form to cause neurostimulation in the retina and find that ultrasound acts via radiation force leading to a mechanical displacement of tissue. We further show that standing waves have a strong modulatory effect on activity. Our quantitative model by which ultrasound generates radiation force and leads to neural activity will be important in optimizing ultrasonic neurostimulation across a wide range of applications.
Collapse
|
122
|
Feng B, Chen L, Ilham SJ. A review on ultrasonic neuromodulation of the peripheral nervous system: enhanced or suppressed activities? APPLIED SCIENCES-BASEL 2019; 9. [PMID: 34113463 PMCID: PMC8188893 DOI: 10.3390/app9081637] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Ultrasonic (US) neuromodulation has emerged as a promising therapeutic means by delivering focused energy deep into the tissue. Low-intensity ultrasound (US) directly activates and/or inhibits neurons in the central nervous system (CNS). US neuromodulation of the peripheral nervous system (PNS) is less developed and rarely used clinically. Literature on the neuromodulatory effects of US on the PNS is controversy with some documenting enhanced neural activities, some showing suppressed activities, and others reporting mixed effects. US, with different range of intensity and strength, is likely to generate distinct physical effects in the stimulated neuronal tissues, which underlies different experimental outcomes in the literature. In this review, we summarize all the major reports that documented the effects of US on peripheral nerve endings, axons, and/or somata in the dorsal root ganglion. In particular, we thoroughly discuss the potential impacts by the following key parameters to the study outcomes of PNS neuromodulation by the US: frequency, pulse repetition frequency, duty cycle, intensity, metrics for peripheral neural activities, and type of biological preparations used in the studies. Potential mechanisms of peripheral US neuromodulation are summarized to provide a plausible interpretation to the seemly contradictory effects of enhanced and suppressed neural activities from US neuromodulation.
Collapse
Affiliation(s)
- Bin Feng
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
- Correspondence: ; Tel.: (001-860-486-6435)
| | - Longtu Chen
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
| | - Sheikh J. Ilham
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
| |
Collapse
|
123
|
Lemaire T, Neufeld E, Kuster N, Micera S. Understanding ultrasound neuromodulation using a computationally efficient and interpretable model of intramembrane cavitation. J Neural Eng 2019; 16:046007. [PMID: 30952150 DOI: 10.1088/1741-2552/ab1685] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
OBJECTIVE Low-intensity focused ultrasound stimulation (LIFUS) emerges as an attracting technology for noninvasive modulation of neural circuits, yet the underlying action mechanisms remain unclear. The neuronal intramembrane cavitation excitation (NICE) model suggests that LIFUS excites neurons through a complex interplay between microsecond-scale mechanical oscillations of so-called sonophores in the plasma membrane and the development of a millisecond-scale electrical response. This model predicts cell-type-specific responses that correlate indirectly with experimental data, but it is computationally expensive and difficult to interpret, which hinders its potential validation. Here, we introduce a multi-scale optimized neuronal intramembrane cavitation (SONIC) model to achieve fast, accurate simulations and confer interpretability in terms of effective electrical response. APPROACH The NICE system is recast in terms of smoothly evolving differential variables affected by cycle averaged internal variables that are a function of sonophore size and charge density, stimulus frequency and pressure amplitude. Problem separation allows to precompute lookup tables for these functions, which are interpolated at runtime to compute coarse-grained, electrophysiologically interpretable and spatially distributed predictions of neural responses. MAIN RESULTS The SONIC model accelerates computation by more than three orders of magnitude, accurately captures millisecond-scale electrical responses of various cortical and thalamic neurons and offers an increased interpretability to the effects of ultrasonic stimuli in terms of effective membrane dynamics. Using this model, we explain how different spiking behaviors can be achieved in cortical neurons by varying LIFUS parameters, and interpret predictions of spike amplitude and firing rate in light of the effective electrical system. We demonstrate the substantial influence of sonophore size on excitation thresholds, and use a nanoscale spatially extended SONIC model to suggest that partial sonophore membrane coverage has a limited impact on neuronal excitability. SIGNIFICANCE By providing an electrophysiologically interpretable description, the SONIC model clarifies cell-type-specific LIFUS neuromodulation according to the intramembrane cavitation hypothesis.
Collapse
Affiliation(s)
- Théo Lemaire
- Translational Neural Engineering Laboratory, Center for Neuroprosthetics and Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | | | | | | |
Collapse
|
124
|
Li G, Qiu W, Zhang Z, Jiang Q, Su M, Cai R, Li Y, Cai F, Deng Z, Xu D, Zhang H, Zheng H. Noninvasive Ultrasonic Neuromodulation in Freely Moving Mice. IEEE Trans Biomed Eng 2019; 66:217-224. [DOI: 10.1109/tbme.2018.2821201] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
125
|
Sharabi S, Daniels D, Last D, Guez D, Zivli Z, Castel D, Levy Y, Volovick A, Grinfeld J, Rachmilevich I, Amar T, Mardor Y, Harnof S. Non-thermal focused ultrasound induced reversible reduction of essential tremor in a rat model. Brain Stimul 2019; 12:1-8. [DOI: 10.1016/j.brs.2018.08.014] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2017] [Revised: 08/12/2018] [Accepted: 08/22/2018] [Indexed: 12/18/2022] Open
|
126
|
Lin JW, Yu F, Müller WS, Ehnholm G, Okada Y. Focused ultrasound transiently increases membrane conductance in isolated crayfish axon. J Neurophysiol 2018; 121:480-489. [PMID: 30565960 DOI: 10.1152/jn.00541.2018] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
We report a novel phenomenon produced by focused ultrasound (US) that may be important for understanding its effects on cell membranes. When a US burst (2.1 MHz, 1-mm focal diameter, 0.1-1 MPa) was focused on a motor axon of the crayfish neuromuscular junction, it consistently produced a fast hyperpolarization, which was followed or superseded by subthreshold depolarizations or action potentials in a stochastic manner. The depolarization persisted in the presence of voltage-gated channel blockers [1 µM TTX ( INa), 50 µM ZD7288 ( Ih), and 200 µM 4-aminopyridine ( IK)] and typically started shortly after the onset of a 5-ms US burst, with a mean latency of 3.35 ± 0.53 ms (SE). The duration and amplitude of depolarizations averaged 2.13 ± 0.87 s and 10.1 ± 2.09 mV, with a maximum of 200 s and 60 mV, respectively. The US-induced depolarization was always associated with a decrease in membrane resistance. By measuring membrane potential and resistance during the US-induced depolarization, the reversal potential of US-induced conductance ( gus) was estimated to be -8.4 ± 2.3 mV, suggesting a nonselective conductance. The increase in gus was 10-100 times larger than the leak conductance; thus it could significantly influence neuronal activity. This change in conductance may be due to stimulation of mechanoreceptors. Alternatively, US may perturb the lateral motion of phospholipids and produce nanopores, which then increase gus. These results may be important for understanding mechanisms underlying US-mediated modulation of neuronal activity and brain function. NEW & NOTEWORTHY We report a specific increase in membrane conductance produced by ultrasound (US) on neuronal membrane. When a 5-ms US tone burst was focused on a crayfish motor axon, it stochastically triggered either depolarization or a spike train. The depolarization was up to 60 mV in amplitude and 200 s in duration and therefore could significantly influence neuronal activity. Depolarization was still evoked by US burst in the presence of Na+ and Ca2+ channel blockers and had a reversal potential of -8.4 ± 2.3 mV, suggesting a nonselective permeability. US can be applied noninvasively in the form of a focused beam to deep brain areas through the skull and has been shown to modulate brain activity. Understanding the depolarization reported here should be helpful for improving the use of US for noninvasive modulation and stimulation in brain-related disease.
Collapse
Affiliation(s)
- Jen-Wei Lin
- Department of Biology, Boston University , Boston, Massachusetts
| | - Feiyuan Yu
- Department of Biology, Boston University , Boston, Massachusetts
| | - Wolfgang S Müller
- Division of Newborn Medicine, Department of Medicine, Boston Children's Hospital and Harvard Medical School , Boston, Massachusetts
| | - Gösta Ehnholm
- Department of Neuroscience and Biomedical Engineering, Aalto University, Aalto, Finland
| | - Yoshio Okada
- Division of Newborn Medicine, Department of Medicine, Boston Children's Hospital and Harvard Medical School , Boston, Massachusetts
| |
Collapse
|
127
|
Yuan Y, Wang X, Yan J, Li X. The effect of anesthetic dose on the motor response induced by low-intensity pulsed ultrasound stimulation. BMC Neurosci 2018; 19:78. [PMID: 30509160 PMCID: PMC6278113 DOI: 10.1186/s12868-018-0476-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2018] [Accepted: 11/22/2018] [Indexed: 01/21/2023] Open
Abstract
Background Low-intensity pulsed ultrasound stimulation (LIPUS) has been proven to be a noninvasive method with high spatial resolution and deep penetration. Previous studies have qualitatively demonstrated that the electromyographic response caused by LIPUS in the mouse motor cortex is affected by the anesthetic state of the mice. However, the quantitative relationship between motor response and anesthetic dose remains unclear. Results Experimental results show that the success rate decreases stepwise as the isoflurane concentration/mouse weight ratio increases (ratios: [0.004%/g, 0.01%/g], success rate: ~ 90%; [0.012%/g, 0.014%/g], ~ 40%; [0.016%/g, 0.018%/g], ~ 7%; 0.024%/g, 0). The latency and duration of EMG increase significantly when the ratio is more than 0.016%/g. Compared with that at ratios from 0.004 to 0.016%/g, normalized EMG amplitude decreases significantly at ratios of 0.018%/g and 0.020%/g. Conclusions Quantitative calculations indicate that the anesthetic dose has a significant regulatory effect on the motor response of mice during LIPUS. Our results have guiding significance for the selection of the anesthetic dose for LIPUS in mouse motor cortex experiments.
Collapse
Affiliation(s)
- Yi Yuan
- Institute of Electrical Engineering, Yanshan University, Qinhuangdao, 066004, China.
| | - Xingran Wang
- Institute of Electrical Engineering, Yanshan University, Qinhuangdao, 066004, China
| | - Jiaqing Yan
- College of Electrical and Control Engineering, North China University of Technology, Beijing, 10041, China
| | - Xiaoli Li
- State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Beijing, 100875, China.
| |
Collapse
|
128
|
Ai L, Bansal P, Mueller JK, Legon W. Effects of transcranial focused ultrasound on human primary motor cortex using 7T fMRI: a pilot study. BMC Neurosci 2018; 19:56. [PMID: 30217150 PMCID: PMC6137744 DOI: 10.1186/s12868-018-0456-6] [Citation(s) in RCA: 84] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Accepted: 08/31/2018] [Indexed: 01/28/2023] Open
Abstract
BACKGROUND Transcranial focused ultrasound (tFUS) is a new non-invasive neuromodulation technique that uses mechanical energy to modulate neuronal excitability with high spatial precision. tFUS has been shown to be capable of modulating EEG brain activity in humans that is spatially restricted, and here, we use 7T MRI to extend these findings. We test the effect of tFUS on 7T BOLD fMRI signals from individual finger representations in the human primary motor cortex (M1) and connected cortical motor regions. Participants (N = 5) performed a cued finger tapping task in a 7T MRI scanner with their thumb, index, and middle fingers to produce a BOLD signal for individual M1 finger representations during either tFUS or sham neuromodulation to the thumb representation. RESULTS Results demonstrated a statistically significant increase in activation volume of the M1 thumb representation for the tFUS condition as compared to sham. No differences in percent BOLD changes were found. This effect was spatially confined as the index and middle finger M1 finger representations did not show similar significant changes in either percent change or activation volume. No effects were seen during tFUS to M1 in the supplementary motor area or the dorsal premotor cortex. CONCLUSIONS Single element tFUS can be paired with high field MRI that does not induce significant artifact. tFUS increases activation volumes of the targeted finger representation that is spatially restricted within M1 but does not extend to functionally connected motor regions. Trial registration ClinicalTrials.gov NCT03634631 08/14/18.
Collapse
Affiliation(s)
- Leo Ai
- Division of Physical Therapy and Division of Rehabilitation Science, Department of Rehabilitation Medicine, Medical School, University of Minnesota, 426 Church St. SE Rm 361, Minneapolis, MN 55455 USA
| | - Priya Bansal
- Division of Physical Therapy and Division of Rehabilitation Science, Department of Rehabilitation Medicine, Medical School, University of Minnesota, 426 Church St. SE Rm 361, Minneapolis, MN 55455 USA
| | - Jerel K. Mueller
- Division of Physical Therapy and Division of Rehabilitation Science, Department of Rehabilitation Medicine, Medical School, University of Minnesota, 426 Church St. SE Rm 361, Minneapolis, MN 55455 USA
| | - Wynn Legon
- Division of Physical Therapy and Division of Rehabilitation Science, Department of Rehabilitation Medicine, Medical School, University of Minnesota, 426 Church St. SE Rm 361, Minneapolis, MN 55455 USA
- Department of Neurological Surgery, School of Medicine, University of Virginia, 409 Lane Rd. Rm 1031, Charlottesville, VA 22901 USA
| |
Collapse
|
129
|
Tarnaud T, Joseph W, Martens L, Tanghe E. Computational Modeling of Ultrasonic Subthalamic Nucleus Stimulation. IEEE Trans Biomed Eng 2018; 66:1155-1164. [PMID: 30188811 DOI: 10.1109/tbme.2018.2869042] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE To explore the potential of ultrasonic modulation of plateau-potential generating subthalamic nucleus neurons (STN), by modeling their interaction with continuous and pulsed ultrasonic waves. METHODS A computational model for ultrasonic stimulation of the STN is created by combining the Otsuka-model with the bilayer sonophore model. The neuronal response to continuous and pulsed ultrasonic waves is computed in parallel for a range of frequencies, duty cycles, pulse repetition frequencies, and intensities. RESULTS Ultrasonic intensity in continuous-wave stimulation determines the firing pattern of the STN. Three observed spiking modes in order of increasing intensity are low frequency spiking, high frequency spiking with significant spike-frequency and spike-amplitude adaptation, and a silenced mode. Continuous-wave stimulation has little capability to manipulate the saturated spiking rate in the high frequency spiking mode. In contrast, STN firing rates induced by pulsed ultrasound insonication will saturate to the pulse repetition frequency with short latencies, for sufficiently large intensity and repetition frequency. CONCLUSION Computational results show that the activity of plateau-potential generating STN can be modulated by selection of the stimulus parameters. Low intensities result in repetitive firing, while higher intensities silence the STN. Pulsed ultrasonic stimulation results in a shorter saturation latency and is able to modulate spiking rates. SIGNIFICANCE Stimulation or suppresion of the STN is important in the treatment of Parkinson's disease, e.g., in deep brain stimulation. This explorative study on ultrasonic modulation of the STN, could be a step in the direction of minimally invasive alternatives to conventional deep brain stimulation.
Collapse
|
130
|
Low-intensity ultrasound neuromodulation: An overview of mechanisms and emerging human applications. Brain Stimul 2018; 11:1209-1217. [PMID: 30166265 DOI: 10.1016/j.brs.2018.08.013] [Citation(s) in RCA: 152] [Impact Index Per Article: 25.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2018] [Revised: 07/26/2018] [Accepted: 08/19/2018] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND There is an emerging need for noninvasive neuromodulation techniques to improve patient outcomes while minimizing adverse events and morbidity. Low-intensity focused ultrasound (LIFUS) is gaining traction as a non-surgical experimental approach of modulating brain activity. Several LIFUS sonication parameters have been found to potentiate neural firing, suppress cortical and epileptic discharges, and alter behavior when delivered to cortical and subcortical mammalian brain regions. OBJECTIVE This review introduces the elements of an effective sonication protocol and summarizes key preclinical studies on LIFUS as a neuromodulation modality. The state of the art in human ultrasound neuromodulation is then comprehensively summarized, and current hypotheses regarding the underlying mechanism of action on neural activity are presented. METHODS Peer-reviewed literature on human ultrasound neuromodulation was obtained by searching several electronic databases. The abstracts of all reports were read and publications which examined low-intensity transcranial ultrasound applied to human subjects were selected for review. RESULTS LIFUS can noninvasively influence human brain activity by suppressing cortical evoked potentials, influencing cortical oscillatory dynamics, and altering outcomes of sensory/motor tasks compared to sham sonication. Proposed mechanisms include cavitation, direct effects on neural ion channels, and plasma membrane deformation. CONCLUSIONS Though optimal sonication paradigms and transcranial delivery methods are still being established, future applications may include non-invasive human brain mapping experiments, and nonsurgical treatments for functional neurological disorders.
Collapse
|
131
|
Legon W, Bansal P, Tyshynsky R, Ai L, Mueller JK. Transcranial focused ultrasound neuromodulation of the human primary motor cortex. Sci Rep 2018; 8:10007. [PMID: 29968768 PMCID: PMC6030101 DOI: 10.1038/s41598-018-28320-1] [Citation(s) in RCA: 179] [Impact Index Per Article: 29.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Accepted: 06/19/2018] [Indexed: 12/17/2022] Open
Abstract
Transcranial focused ultrasound is an emerging form of non-invasive neuromodulation that uses acoustic energy to affect neuronal excitability. The effect of ultrasound on human motor cortical excitability and behavior is currently unknown. We apply ultrasound to the primary motor cortex in humans using a novel simultaneous transcranial ultrasound and magnetic stimulation paradigm that allows for concurrent and concentric ultrasound stimulation with transcranial magnetic stimulation (TMS). This allows for non-invasive inspection of the effect of ultrasound on motor neuronal excitability using the motor evoked potential (MEP). We test the effect of ultrasound on single pulse MEP recruitment curves and paired pulse protocols including short interval intracortical inhibition (SICI) and intracortical facilitation (ICF). In addition, we test the effect of ultrasound to motor cortex on a stimulus response reaction time task. Results show ultrasound inhibits the amplitude of single-pulse MEPs and attenuates intracortical facilitation but does not affect intracortical inhibition. Ultrasound also reduces reaction time on a simple stimulus response task. This is the first report of the effect of ultrasound on human motor cortical excitability and motor behavior and confirms previous results in the somatosensory cortex that ultrasound results in effective neuronal inhibition that confers a performance advantage.
Collapse
Affiliation(s)
- Wynn Legon
- Division of Physical Therapy and Division of Rehabilitation Science, Department of Rehabilitation Medicine, Medical School, University of Minnesota, Minneapolis, MN, USA.
- Department of Neurosurgery, School of Medicine, University of Virginia, Charlottesville, VA, United States.
| | - Priya Bansal
- Division of Physical Therapy and Division of Rehabilitation Science, Department of Rehabilitation Medicine, Medical School, University of Minnesota, Minneapolis, MN, USA
| | - Roman Tyshynsky
- Department of Neuroscience, University of Minnesota, Minneapolis, MN, USA
| | - Leo Ai
- Division of Physical Therapy and Division of Rehabilitation Science, Department of Rehabilitation Medicine, Medical School, University of Minnesota, Minneapolis, MN, USA
| | - Jerel K Mueller
- Division of Physical Therapy and Division of Rehabilitation Science, Department of Rehabilitation Medicine, Medical School, University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|
132
|
Prieto ML, Firouzi K, Khuri-Yakub BT, Maduke M. Activation of Piezo1 but Not Na V1.2 Channels by Ultrasound at 43 MHz. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:1217-1232. [PMID: 29525457 PMCID: PMC5914535 DOI: 10.1016/j.ultrasmedbio.2017.12.020] [Citation(s) in RCA: 93] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2017] [Revised: 12/19/2017] [Accepted: 12/22/2017] [Indexed: 05/19/2023]
Abstract
Ultrasound (US) can modulate the electrical activity of the excitable tissues, but the mechanisms underlying this effect are not understood at the molecular level or in terms of the physical modality through which US exerts its effects. Here, we report an experimental system that allows for stable patch-clamp recording in the presence of US at 43 MHz, a frequency known to stimulate neural activity. We describe the effects of US on two ion channels proposed to be involved in the response of excitable cells to US: the mechanosensitive Piezo1 channel and the voltage-gated sodium channel NaV1.2. Our patch-clamp recordings, together with finite-element simulations of acoustic field parameters indicate that Piezo1 channels are activated by continuous wave US at 43 MHz and 50 or 90 W/cm2 through cell membrane stress caused by acoustic streaming. NaV1.2 channels were not affected through this mechanism at these intensities, but their kinetics could be accelerated by US-induced heating.
Collapse
Affiliation(s)
- Martin Loynaz Prieto
- Department of Molecular and Cellular Physiology, Stanford University School of Medicine, Stanford, CA, USA
| | - Kamyar Firouzi
- E. L. Ginzton Laboratory, Stanford University, Stanford, CA, USA
| | | | - Merritt Maduke
- Department of Molecular and Cellular Physiology, Stanford University School of Medicine, Stanford, CA, USA.
| |
Collapse
|
133
|
Yang PF, Phipps MA, Newton AT, Chaplin V, Gore JC, Caskey CF, Chen LM. Neuromodulation of sensory networks in monkey brain by focused ultrasound with MRI guidance and detection. Sci Rep 2018; 8:7993. [PMID: 29789605 PMCID: PMC5964220 DOI: 10.1038/s41598-018-26287-7] [Citation(s) in RCA: 57] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2018] [Accepted: 05/08/2018] [Indexed: 01/16/2023] Open
Abstract
Focused ultrasound (FUS) has gained recognition as a technique for non-invasive neuromodulation with high spatial precision and the ability to both excite and inhibit neural activity. Here we demonstrate that MRI-guided FUS is capable of exciting precise targets within areas 3a/3b in the monkey brain, causing downstream activations in off-target somatosensory and associated brain regions which are simultaneously detected by functional MRI. The similarity between natural tactile stimulation-and FUS- evoked fMRI activation patterns suggests that FUS likely can excite populations of neurons and produce associated spiking activities that may be subsequently transmitted to other functionally related touch regions. The across-region differences in fMRI signal changes relative to area 3a/3b between tactile and FUS conditions also indicate that FUS modulated the tactile network differently. The significantly faster rising (>1 sec) fMRI signals elicited by direct FUS stimulation at the targeted cortical region suggest that a different neural hemodynamic coupling mechanism may be involved in generating fMRI signals. This is the first demonstration of imaging neural excitation effects of FUS with BOLD fMRI on a specific functional circuit in non-human primates.
Collapse
Affiliation(s)
- Pai-Feng Yang
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
- Vanderbilt University Institute of Imaging Science, Nashville, TN, USA
| | - M Anthony Phipps
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
- Vanderbilt University Institute of Imaging Science, Nashville, TN, USA
| | - Allen T Newton
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
- Vanderbilt University Institute of Imaging Science, Nashville, TN, USA
| | - Vandiver Chaplin
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
- Vanderbilt University Institute of Imaging Science, Nashville, TN, USA
| | - John C Gore
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
- Vanderbilt University Institute of Imaging Science, Nashville, TN, USA
| | - Charles F Caskey
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA.
- Vanderbilt University Institute of Imaging Science, Nashville, TN, USA.
| | - Li Min Chen
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA.
- Vanderbilt University Institute of Imaging Science, Nashville, TN, USA.
| |
Collapse
|
134
|
Daniels D, Sharabi S, Last D, Guez D, Salomon S, Zivli Z, Castel D, Volovick A, Grinfeld J, Rachmilevich I, Amar T, Liraz-Zaltsman S, Sargsyan N, Mardor Y, Harnof S. Focused Ultrasound-Induced Suppression of Auditory Evoked Potentials in Vivo. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:1022-1030. [PMID: 29501283 DOI: 10.1016/j.ultrasmedbio.2018.01.010] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2016] [Revised: 09/29/2017] [Accepted: 01/12/2018] [Indexed: 06/08/2023]
Abstract
The goal of this study was to determine the feasibility of focused ultrasound-based neuromodulation affecting auditory evoked potentials (AEPs) in animals. Focused ultrasound-induced suppression of AEPs was performed in 22 rats and 5 pigs: Repetitive sounds were produced, and the induced AEPs were recorded before and repeatedly after FUS treatment of the auditory pathway. All treated animals exhibited a decrease in AEP amplitude post-treatment in contrast to animals undergoing the sham treatment. Suppression was weaker for rats treated at 2.3 W/cm2 (amplitudes decreased to 59.8 ± 3.3% of baseline) than rats treated at 4.6 W/cm2 (36.9 ± 7.5%, p <0.001). Amplitudes of the treated pigs decreased to 27.7 ± 5.9% of baseline. This effect lasted between 30 min and 1 mo in most treated animals. No evidence of heating during treatment or later brain damage/edema was observed. These results demonstrate the feasibility of inducing significant neuromodulation with non-thermal, non-invasive, reversible focused ultrasound. The long recovery times may have clinical implications.
Collapse
Affiliation(s)
- Dianne Daniels
- Advanced Technology Center, Sheba Medical Center, Ramat-Gan, Israel.
| | - Shirley Sharabi
- Advanced Technology Center, Sheba Medical Center, Ramat-Gan, Israel
| | - David Last
- Advanced Technology Center, Sheba Medical Center, Ramat-Gan, Israel
| | - David Guez
- Advanced Technology Center, Sheba Medical Center, Ramat-Gan, Israel
| | - Sharona Salomon
- Advanced Technology Center, Sheba Medical Center, Ramat-Gan, Israel
| | - Zion Zivli
- Neurosurgery Department, Sheba Medical Center, Ramat-Gan, Israel; Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| | - David Castel
- Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel; Neufeld Cardiac Research Institute, Sheba Medical Center, Ramat-Gan, Israel
| | | | | | | | | | - Sigal Liraz-Zaltsman
- The Joseph Sagol Neuroscience Center, Sheba Medical Center, Ramat-Gan, Israel; School of Pharmacy, The Hebrew University of Jerusalem, Jerusalem, Israel
| | - Narek Sargsyan
- Faculty of Medicine, St. Georges University, London, United Kingdom
| | - Yael Mardor
- Advanced Technology Center, Sheba Medical Center, Ramat-Gan, Israel; Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| | - Sagi Harnof
- Neurosurgery Department, Sheba Medical Center, Ramat-Gan, Israel; Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| |
Collapse
|
135
|
Soloperto A, Boccaccio A, Contestabile A, Moroni M, Hallinan GI, Palazzolo G, Chad J, Deinhardt K, Carugo D, Difato F. Mechano-sensitization of mammalian neuronal networks through expression of the bacterial large-conductance mechanosensitive ion channel. J Cell Sci 2018; 131:jcs210393. [PMID: 29361543 PMCID: PMC5897719 DOI: 10.1242/jcs.210393] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Accepted: 01/13/2018] [Indexed: 12/11/2022] Open
Abstract
Development of remote stimulation techniques for neuronal tissues represents a challenging goal. Among the potential methods, mechanical stimuli are the most promising vectors to convey information non-invasively into intact brain tissue. In this context, selective mechano-sensitization of neuronal circuits would pave the way to develop a new cell-type-specific stimulation approach. We report here, for the first time, the development and characterization of mechano-sensitized neuronal networks through the heterologous expression of an engineered bacterial large-conductance mechanosensitive ion channel (MscL). The neuronal functional expression of the MscL was validated through patch-clamp recordings upon application of calibrated suction pressures. Moreover, we verified the effective development of in-vitro neuronal networks expressing the engineered MscL in terms of cell survival, number of synaptic puncta and spontaneous network activity. The pure mechanosensitivity of the engineered MscL, with its wide genetic modification library, may represent a versatile tool to further develop a mechano-genetic approach.This article has an associated First Person interview with the first author of the paper.
Collapse
Affiliation(s)
- Alessandro Soloperto
- Neuroscience and Brain Technologies Dept., Istituto Italiano di Tecnologia, 16163 Genoa, Italy
| | - Anna Boccaccio
- Institute of Biophysics, National Research Council of Italy, 16149 Genoa, Italy
| | - Andrea Contestabile
- Neuroscience and Brain Technologies Dept., Istituto Italiano di Tecnologia, 16163 Genoa, Italy
| | - Monica Moroni
- Center for Neuroscience and Cognitive Systems, Istituto Italiano di Tecnologia, 38068 Rovereto, Italy
| | - Grace I Hallinan
- Biological Sciences and Institute for Life Sciences, University of Southampton, SO17 1BJ Southampton, UK
| | - Gemma Palazzolo
- Neuroscience and Brain Technologies Dept., Istituto Italiano di Tecnologia, 16163 Genoa, Italy
| | - John Chad
- Biological Sciences and Institute for Life Sciences, University of Southampton, SO17 1BJ Southampton, UK
| | - Katrin Deinhardt
- Biological Sciences and Institute for Life Sciences, University of Southampton, SO17 1BJ Southampton, UK
| | - Dario Carugo
- Faculty of Engineering and the Environment, University of Southampton, SO17 1BJ Southampton, UK
| | - Francesco Difato
- Neuroscience and Brain Technologies Dept., Istituto Italiano di Tecnologia, 16163 Genoa, Italy
| |
Collapse
|
136
|
Abstract
The understanding of brain function and the capacity to treat neurological and psychiatric disorders rest on the ability to intervene in neuronal activity in specific brain circuits. Current methods of neuromodulation incur a tradeoff between spatial focus and the level of invasiveness. Transcranial focused ultrasound (FUS) is emerging as a neuromodulation approach that combines noninvasiveness with focus that can be relatively sharp even in regions deep in the brain. This may enable studies of the causal role of specific brain regions in specific behaviors and behavioral disorders. In addition to causal brain mapping, the spatial focus of FUS opens new avenues for treatments of neurological and psychiatric conditions. This review introduces existing and emerging FUS applications in neuromodulation, discusses the mechanisms of FUS effects on cellular excitability, considers the effects of specific stimulation parameters, and lays out the directions for future work.
Collapse
Affiliation(s)
- Jan Kubanek
- Departments of Neurobiology and Radiology, Stanford University School of Medicine, Stanford, California
| |
Collapse
|
137
|
Weissler Y, Farah N, Shoham S. Simulation of morphologically structured photo-thermal neural stimulation. J Neural Eng 2017; 14:055001. [PMID: 28820744 DOI: 10.1088/1741-2552/aa7805] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Rational design of next-generation techniques for photo-thermal excitation requires the development of tools capable of modeling the effects of spatially- and temporally-dependent temperature distribution on cellular neuronal structures. APPROACH We present a new computer simulation tool for predicting the effects of arbitrary spatiotemporally-structured photo-thermal stimulation on 3D, morphologically realistic neurons. The new simulation tool is based on interfacing two generic platforms, NEURON and MATLAB and is therefore suited for capturing different kinds of stimuli and neural models. MAIN RESULTS Simulation results are validated using photo-absorber induced neuro-thermal stimulation (PAINTS) empirical results, and advanced features are explored. SIGNIFICANCE The new simulation tool could have an important role in understanding and investigating complex optical stimulation at the single-cell and network levels.
Collapse
Affiliation(s)
- Y Weissler
- The Faculty of Biomedical Engineering and Russel-Berrie Nanoscience and Nanotechnology Institute, Technion-Israel Institute of Technology, Haifa, Israel
| | | | | |
Collapse
|
138
|
Transcranial ultrasonic stimulation modulates single-neuron discharge in macaques performing an antisaccade task. Brain Stimul 2017; 10:1024-1031. [PMID: 28789857 DOI: 10.1016/j.brs.2017.07.007] [Citation(s) in RCA: 90] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2017] [Revised: 07/15/2017] [Accepted: 07/19/2017] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Low intensity transcranial ultrasonic stimulation (TUS) has been demonstrated to non-invasively and transiently stimulate the nervous system. Although US neuromodulation has appeared robust in rodent studies, the effects of US in large mammals and humans have been modest at best. In addition, there is a lack of direct recordings from the stimulated neurons in response to US. Our study investigates the magnitude of the US effects on neuronal discharge in awake behaving monkeys and thus fills the void on both fronts. OBJECTIVE/HYPOTHESIS In this study, we demonstrate the feasibility of recording action potentials in the supplementary eye field (SEF) as TUS is applied simultaneously to the frontal eye field (FEF) in macaques performing an antisaccade task. RESULTS We show that compared to a control stimulation in the visual cortex, SEF activity is significantly modulated shortly after TUS onset. Among all cell types 40% of neurons significantly changed their activity after TUS. Half of the neurons showed a transient increase of activity induced by TUS. CONCLUSION Our study demonstrates that the neuromodulatory effects of non-invasive focused ultrasound can be assessed in real time in awake behaving monkeys by recording discharge activity from a brain region reciprocally connected with the stimulated region. The study opens the door for further parametric studies for fine-tuning the ultrasonic parameters. The ultrasonic effect could indeed be quantified based on the direct measurement of the intensity of the modulation induced on a single neuron in a freely performing animal. The technique should be readily reproducible in other primate laboratories studying brain function, both for exploratory and therapeutic purposes and to facilitate the development of future clinical TUS devices.
Collapse
|
139
|
Lee W, Kim S, Kim B, Lee C, Chung YA, Kim L, Yoo SS. Non-invasive transmission of sensorimotor information in humans using an EEG/focused ultrasound brain-to-brain interface. PLoS One 2017; 12:e0178476. [PMID: 28598972 PMCID: PMC5466306 DOI: 10.1371/journal.pone.0178476] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2016] [Accepted: 05/13/2017] [Indexed: 02/03/2023] Open
Abstract
We present non-invasive means that detect unilateral hand motor brain activity from one individual and subsequently stimulate the somatosensory area of another individual, thus, enabling the remote hemispheric link between each brain hemisphere in humans. Healthy participants were paired as a sender and a receiver. A sender performed a motor imagery task of either right or left hand, and associated changes in the electroencephalogram (EEG) mu rhythm (8-10 Hz) originating from either hemisphere were programmed to move a computer cursor to a target that appeared in either left or right of the computer screen. When the cursor reaches its target, the outcome was transmitted to another computer over the internet, and actuated the focused ultrasound (FUS) devices that selectively and non-invasively stimulated either the right or left hand somatosensory area of the receiver. Small FUS transducers effectively allowed for the independent administration of stimulatory ultrasonic waves to somatosensory areas. The stimulation elicited unilateral tactile sensation of the hand from the receiver, thus establishing the hemispheric brain-to-brain interface (BBI). Although there was a degree of variability in task accuracy, six pairs of volunteers performed the BBI task in high accuracy, transferring approximately eight commands per minute. Linkage between the hemispheric brain activities among individuals suggests the possibility for expansion of the information bandwidth in the context of BBI.
Collapse
Affiliation(s)
- Wonhye Lee
- Incheon St. Mary's Hospital, The Catholic University of Korea, Incheon, Korea.,Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, United States of America
| | - Suji Kim
- Center for Bionics, Korea Institute of Science and Technology, Seoul, Korea
| | - Byeongnam Kim
- Center for Bionics, Korea Institute of Science and Technology, Seoul, Korea
| | - Chungki Lee
- Center for Bionics, Korea Institute of Science and Technology, Seoul, Korea
| | - Yong An Chung
- Incheon St. Mary's Hospital, The Catholic University of Korea, Incheon, Korea
| | - Laehyun Kim
- Center for Bionics, Korea Institute of Science and Technology, Seoul, Korea
| | - Seung-Schik Yoo
- Incheon St. Mary's Hospital, The Catholic University of Korea, Incheon, Korea.,Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, United States of America.,Center for Bionics, Korea Institute of Science and Technology, Seoul, Korea
| |
Collapse
|
140
|
Baek H, Pahk KJ, Kim H. A review of low-intensity focused ultrasound for neuromodulation. Biomed Eng Lett 2017; 7:135-142. [PMID: 30603160 PMCID: PMC6208465 DOI: 10.1007/s13534-016-0007-y] [Citation(s) in RCA: 90] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2016] [Revised: 11/05/2016] [Accepted: 11/16/2016] [Indexed: 12/14/2022] Open
Abstract
The ability of ultrasound to be focused into a small region of interest through the intact skull within the brain has led researchers to investigate its potential therapeutic uses for functional neurosurgery and tumor ablation. Studies have used high-intensity focused ultrasound to ablate tissue in localised brain regions for movement disorders and chronic pain while sparing the overlying and surrounding tissue. More recently, low-intensity focused ultrasound (LIFU) that induces reversible biological effects has been emerged as an alternative neuromodulation modality due to its bi-modal (i.e. excitation and suppression) capability with exquisite spatial specificity and depth penetration. Many compelling evidences of LIFU-mediated neuromodulatory effects including behavioral responses, electrophysiological recordings and functional imaging data have been found in the last decades. LIFU, therefore, has the enormous potential to improve the clinical outcomes as well as to replace the currently available neuromodulation techniques such as deep brain stimulation (DBS), transcranial magnetic stimulation and transcranial current stimulation. In this paper, we aim to provide a summary of pioneering studies in the field of ultrasonic neuromodulation including its underlying mechanisms that were published in the last 60 years. In closing, some of potential clinical applications of ultrasonic brain stimulation will be discussed.
Collapse
Affiliation(s)
- Hongchae Baek
- Center for Bionics, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Hwarangno 14-gil 5, Seongbuk-gu, Seoul, 02792 Republic of Korea
| | - Ki Joo Pahk
- Center for Bionics, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Hwarangno 14-gil 5, Seongbuk-gu, Seoul, 02792 Republic of Korea
| | - Hyungmin Kim
- Center for Bionics, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Hwarangno 14-gil 5, Seongbuk-gu, Seoul, 02792 Republic of Korea
| |
Collapse
|
141
|
Fishman PS, Frenkel V. Focused Ultrasound: An Emerging Therapeutic Modality for Neurologic Disease. Neurotherapeutics 2017; 14:393-404. [PMID: 28244011 PMCID: PMC5398988 DOI: 10.1007/s13311-017-0515-1] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Therapeutic ultrasound is only beginning to be applied to neurologic conditions, but the potential of this modality for a wide spectrum of brain applications is high. Engineering advances now allow sound waves to be targeted through the skull to a brain region selected with real time magnetic resonance imaging and thermography, using a commercial array of focused emitters. High intensities of sonic energy can create a coagulation lesion similar to that of older radiofrequency stereotactic methods, but without opening the skull. This has led to the recent Food and Drug Administration approval of focused ultrasound (FUS) thalamotomy for unilateral treatment of essential tremor. Clinical studies of stereotactic FUS for aspects of Parkinson's disease, chronic pain, and refractory psychiatric indications are underway, with promising results. Moderate-intensity FUS has the potential to safely open the blood-brain barrier for localized delivery of therapeutics, while low levels of sonic energy can be used as a form of neuromodulation.
Collapse
Affiliation(s)
- Paul S Fishman
- Department of Neurology, University of Maryland School of Medicine, Baltimore, MD, 21201, USA.
| | - Victor Frenkel
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, MD, 21201, USA
| |
Collapse
|
142
|
Abstract
Ultrasound (US) is widely known for its utility as a biomedical imaging modality. An abundance of evidence has recently accumulated showing that US is also useful for non-invasively modulating brain circuit activity. Through a series of studies discussed in this short review, it has recently become recognized that transcranial focused ultrasound can exert mechanical (non-thermal) bioeffects on neurons and cells to produce focal changes in the activity of brain circuits. In addition to highlighting scientific breakthroughs and observations that have driven the development of the field of ultrasonic neuromodulation, this study also provides a discussion of mechanisms of action underlying the ability of ultrasound to physically stimulate and modulate brain circuit activity. Exemplifying some forward-looking tools that can be developed by integrating ultrasonic neuromodulation with other advanced acoustic technologies, some innovative acoustic imaging, beam forming, and focusing techniques are briefly reviewed. Finally, the future outlook for ultrasonic neuromodulation is discussed, specifically in the context of applications employing transcranial focused ultrasound for the investigation, diagnosis, and treatment of neuropsychiatric disorders.
Collapse
Affiliation(s)
- Maria Fini
- a School of Biological and Health Systems Engineering , Arizona State University , Tempe , AZ , USA
| | - William J Tyler
- a School of Biological and Health Systems Engineering , Arizona State University , Tempe , AZ , USA
| |
Collapse
|
143
|
Li H, Sun J, Zhang D, Omire-Mayor D, Lewin PA, Tong S. Low-intensity (400 mW/cm 2, 500 kHz) pulsed transcranial ultrasound preconditioning may mitigate focal cerebral ischemia in rats. Brain Stimul 2017; 10:695-702. [PMID: 28279642 DOI: 10.1016/j.brs.2017.02.008] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2016] [Revised: 02/10/2017] [Accepted: 02/24/2017] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Preconditioning methods, which could increase tolerance of brain to subsequent ischemic injuries with a small dose of non-injury stimuli, have gained attention. Capitalizing on noninvasiveness and safety of ultrasound modality, the pulsed transcranial ultrasound stimulation (pTUS) approach may provide a novel treatment for patients with high risk of stroke. OBJECTIVE This study's goal was to investigate whether the risk of stroke could be minimized or eliminated by prior exposure to low-intensity, pulsed transcranial ultrasound stimulation (pTUS). METHODS Rats were randomly assigned to control (n = 12) and pTUS preconditioning (pTUS-PC) groups (n = 14). The animals in pTUS-PC group were exposed to transcranial ultrasound stimulation before the induction of photothrombotic stroke, whereas control animals were handled identically but without the ultrasound stimulation. Cerebral blood flow was monitored using laser speckle imaging in both groups during stroke induction, as well as 24 and 48 h after stroke, respectively. Also, infarct volumes and edema were measured at 48 h after stroke. RESULTS pTUS-PC rats had smaller ischemic areas during stroke induction, and 24 and 48 h after the stroke, and smaller infarct volume (1.770 ± 0.169%) than the controls (3.215 ± 0.401%) (p < 0.01). Moreover, the pTUS-PC group experienced lower volume of brain edema than the control group (pTUS-PC rats: 6.658 ± 1.183%; control rats: 12.48 ± 1.386%, p < 0.01). CONCLUSION These results support the hypothesis that transcranial ultrasound stimulation applied before photothrombosis could provide neuroprotection by increasing the brain's tolerance to subsequently induced focal ischemic injury.
Collapse
Affiliation(s)
- Hangdao Li
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China; School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA19104, USA
| | - Junfeng Sun
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Daqu Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Daryl Omire-Mayor
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA19104, USA
| | - Peter A Lewin
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA19104, USA.
| | - Shanbao Tong
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
| |
Collapse
|