151
|
Cobb BL, Jauchem JR, Adair ER. Radial arm maze performance of rats following repeated low level microwave radiation exposure. Bioelectromagnetics 2003; 25:49-57. [PMID: 14696053 DOI: 10.1002/bem.10148] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
We examined the possibility of changes in "working" memory of rats following whole body exposure to microwave (MW) radiation. During each of 10 days, we exposed rats within circularly polarized waveguides for 45 min to 2450 MHz fields at whole body SARs of 0.6 W/kg (2 micros pulses, 500 pps), followed by testing in a 12 arm, radial arm maze (RAM). Rats received a preexposure injection of one of three psychoactive compounds or saline, to determine whether a compound would interact with MW exposure to affect performance in the maze. Error rate, i.e., reentry into arms already visited, and time to criterion data for 10 consecutive days of testing were analyzed by a three way analysis of variance (ANOVA) using main effects of "exposure" and "drug" and a repeated factor of "test day." Our alpha limit for significance was P <.05. Analyzes of error rates revealed no significant exposure effect, no significant drug effect and no significant interaction between the two main factors. There was a significant difference in test days, as expected, with repeated test-trial days, which indicates that learning was accomplished. There was no significant interaction of test day and the other two factors. The results of our analyzes of time to criterion data included no significant exposure effect, a significant drug effect, a significant test day effect, and a significant interaction between drug and test day factors. Post hoc analyzes of the drug factor revealed that rats treated with either physostigmine or nalrexone hydrochloride, took significantly longer to complete the maze task than rats pretreated with saline or with naloxone methodide. We conclude that there is no evidence from the current study that exposure to of MW radiation under parameters examined caused decrements in the ability of rats to learn the spatial memory task.
Collapse
Affiliation(s)
- Brenda L Cobb
- United States Air Force Research Laboratory, Human Effectiveness Directorate, Directed Energy Bioeffects Division, Radio Frequency Radiation Branch, Brooks AFB, Texas, USA.
| | | | | |
Collapse
|
152
|
Mostafa RM, Mostafa YM, Ennaceur A. Effects of exposure to extremely low-frequency magnetic field of 2 G intensity on memory and corticosterone level in rats. Physiol Behav 2002; 76:589-95. [PMID: 12126997 DOI: 10.1016/s0031-9384(02)00730-8] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/09/2022]
Abstract
In the present study, we examined the effects of chronic exposure (1 and 2 weeks) to an extremely low-frequency magnetic field (ELFMF) of 2 G intensity on memory in rats using an object recognition task. Comparable groups of rats were exposed for 1, 2 or 4 weeks to ELFMF and the following day blood samples were collected from each rat for the measurement of corticosterone level. Our results demonstrate that exposure to ELFMF induces a significant increase in the level of corticosterone in blood plasma and is associated with impairment in discrimination between familiar and novel objects.
Collapse
Affiliation(s)
- Randa M Mostafa
- Zagazig University, Banha School of Medicine, Department of Physiology, Banha, Egypt
| | | | | |
Collapse
|
153
|
Santini R, Seigne M, Bonhomme-Faivre L, Bouffet S, Defrasne E, Sage M. SYMPTOMS EXPERIENCED BY USERS OF DIGITAL CELLULAR PHONES: A STUDY OF A FRENCH ENGINEERING SCHOOL. Electromagn Biol Med 2002. [DOI: 10.1081/jbc-120003113] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
154
|
Ozturan O, Erdem T, Miman MC, Kalcioglu MT, Oncel S. Effects of the electromagnetic field of mobile telephones on hearing. Acta Otolaryngol 2002; 122:289-93. [PMID: 12030576 DOI: 10.1080/000164802753648178] [Citation(s) in RCA: 60] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
The widespread use of mobile telephones has given rise to concern about the potential influences of electromagnetic fields (EMFs) on human health. Anatomically, the ear is in close proximity to the mobile telephone during use. Hearing loss due to mobile telephone use has not been described in the medical literature; however, if there is a subtle cochlear involvement, it might be detected by means of changes in evoked otoacoustic emissions (OAEs). Thirty volunteers with normal hearing were exposed to mobile telephone EMFs for 10 min and evoked OAEs were measured before and after exposure. No measurable change in evoked OAEs was detected and none of the subjects reported a deterioration in hearing level. To the best of our knowledge, this is the first study on the effects of EMFs emitted by mobile telephones on hearing. It was concluded that a 10-min exposure to the EMF emitted from a mobile telephone had no effect on hearing, at least at outer ear, middle ear and cochlear levels.
Collapse
Affiliation(s)
- Orhan Ozturan
- Department of Otorhinolaryngology, School of Medicine, Inonu University, Malatya, Turkey.
| | | | | | | | | |
Collapse
|
155
|
Cook CM, Thomas AW, Prato FS. Human electrophysiological and cognitive effects of exposure to ELF magnetic and ELF modulated RF and microwave fields: a review of recent studies. Bioelectromagnetics 2002; 23:144-57. [PMID: 11835261 DOI: 10.1002/bem.107] [Citation(s) in RCA: 94] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The investigation of weak (<500 microT), extremely low frequency (ELF, 0-300 Hz) magnetic field (MF) exposure upon human cognition and electrophysiology has yielded incomplete and contradictory evidence that MFs interact with human biology. This may be due to the small number of studies undertaken examining ELF MF effects upon the human electroencephalogram (EEG), and the associated analysis of evoked related potentials (ERPs). Relatively few studies have examined how MF exposure may affect cognitive and perceptual processing in human subjects. The introduction of this review considers some of the recent studies of ELF MF exposure upon the EEG, ERPs and cognitive and perceptual tasks. We also consider some of the confounding factors within current human MF studies and suggest some new strategies for further experimentation.
Collapse
Affiliation(s)
- C M Cook
- Lawson Health Research Institute, Department of Nuclear Medicine MR, St Joseph's Health Care, London, Ontario, Canada.
| | | | | |
Collapse
|
156
|
Dubreuil D, Jay T, Edeline JM. Does head-only exposure to GSM-900 electromagnetic fields affect the performance of rats in spatial learning tasks? Behav Brain Res 2002; 129:203-10. [PMID: 11809512 DOI: 10.1016/s0166-4328(01)00344-8] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
The rapid expansion of mobile communication has generated intense interest, but has also fuelled ongoing concerns. In both humans and animals, radiofrequency radiations are suspected to affect cognitive functions. More specifically, several studies performed in rodents have suggested that spatial learning can be impaired by electromagnetic field exposure. However, none of these previous studies have simulated the common conditions of GSM mobile phones use. This study is the first using a head-only exposure system emitting a 900-MHz GSM electromagnetic field (pulsed at 217 Hz). The two behavioural tasks that were evaluated here have been used previously to demonstrate performance deficits in spatial learning after electromagnetic field exposure: a classical radial maze elimination task and a spatial navigation task in an open-field arena (dry-land version of the Morris water maze). The performances of rats exposed for 45 min to a 900-MHz electromagnetic field (1 and 3.5 W/kg) were compared to those of sham-exposed and cage-control rats. There were no differences among exposed, sham, and cage-control rats in the two spatial learning tasks. The discussion focuses on the potential reasons that led previous studies to conclude that learning deficits do occur after electromagnetic field exposure.
Collapse
Affiliation(s)
- Diane Dubreuil
- Laboratoire de Neurobiologie de l'Apprentissage, de la Mémoire, et de la Communication, CNRS-UMR 8620, bât. 446, Université Paris Sud, Orsay, France.
| | | | | |
Collapse
|
157
|
Edelstyn N, Oldershaw A. The acute effects of exposure to the electromagnetic field emitted by mobile phones on human attention. Neuroreport 2002; 13:119-21. [PMID: 11924872 DOI: 10.1097/00001756-200201210-00028] [Citation(s) in RCA: 81] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The aim of our study was to investigate the effects of acute mobile phone exposure on a range of tasks which tapped capacity and processing speed within the attentional system. Thirty-eight healthy volunteers were randomly assigned to either an experimental group which was exposed to a connected mobile phone or a control group in which the mobile phone was switched off. Subjects remained blind to mobile phone status throughout duration of study. The experimental group were exposed to an electromagnetic field emitted by a 900 MHz mobile phone for 30 min. Cognitive performance was assessed at three points (prior to mobile phone exposure, at 15 and 30 min post-exposure) using six cognitive neuropsychological tests (digit span and spatial span forwards and backwards, serial subtraction and verbal fluency). Significant differences between the two groups were evident after 5 min on two tests of attentional capacity (digit span forwards and spatial span backwards) and one of processing speed (serial subtraction). In all three instances, performance was facilitated following mobile phone exposure. No deficits were evident. These findings are discussed in terms of possible functional and neuroanatomical bases.
Collapse
|
158
|
de Pomerai DI, Dawe A, Djerbib L, Allan J, Brunt G, Daniells C. Growth and maturation of the nematode Caenorhabditis elegans following exposure to weak microwave fields. Enzyme Microb Technol 2002. [DOI: 10.1016/s0141-0229(01)00459-8] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
159
|
Electromagnetic field of mobile phones affects visual event related potential in patients with narcolepsy. Bioelectromagnetics 2001. [DOI: 10.1002/bem.81] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
160
|
Mausset AL, de Seze R, Montpeyroux F, Privat A. Effects of radiofrequency exposure on the GABAergic system in the rat cerebellum: clues from semi-quantitative immunohistochemistry. Brain Res 2001; 912:33-46. [PMID: 11520491 DOI: 10.1016/s0006-8993(01)02599-9] [Citation(s) in RCA: 62] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The widespread use of cellular phones raises the problem of interaction of electromagnetic fields with the central nervous system (CNS). In order to measure these effects on neurotransmitter content in the CNS, we developed a protocol of neurotransmitter detection based on immunohistochemistry and image analysis. Gamma-vinyl-GABA (GVG), an inhibitor of the GABA-transaminase was injected in rats to increase GABA concentration in the CNS. The cellular GABA contents were then revealed by immunohistochemistry and semi-quantified by image analysis thanks to three parameters: optical density (O.D.), staining area, and number of positive cells. The increase in cerebellar GABA content induced by GVG 1200 mg/kg was reflected in these three parameters in the molecular and the granular layers. Therefore, control of immunohistochemistry parameters, together with appropriate image analysis, allowed both the location and the detection of variations in cellular neurotransmitter content. This protocol was used to investigate the effects of exposure to 900 MHz radiofrequencies on cerebellar GABA content. Both pulsed emission with a specific absorption rate (SAR) of 4 W/kg and continuous emission with high SAR (32 W/kg) were tested. We observed a selective diminution of the stained processes area in the Purkinje cell layer after exposure to pulsed radiofrequency and, in addition, a decrease in O.D. in the three cell layers after exposure to continuous waves. Whether this effect is, at least partly, due to a local heating of the tissues is not known. Overall, it appears that high energetic radiofrequency exposure induces a diminution in cellular GABA content in the cerebellum.
Collapse
Affiliation(s)
- A L Mausset
- Laboratoire de Biophysique Médicale, Faculté de Médecine de Nîmes, Avenue Kennedy, 30907 Cedex 2, Nîmes, France
| | | | | | | |
Collapse
|
161
|
Kwee S, Raskmark P, Velizarov S. CHANGES IN CELLULAR PROTEINS DUE TO ENVIRONMENTAL NON-IONIZING RADIATION. I. HEAT-SHOCK PROTEINS. ACTA ACUST UNITED AC 2001. [DOI: 10.1081/jbc-100104139] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
162
|
Tattersall JE, Scott IR, Wood SJ, Nettell JJ, Bevir MK, Wang Z, Somasiri NP, Chen X. Effects of low intensity radiofrequency electromagnetic fields on electrical activity in rat hippocampal slices. Brain Res 2001; 904:43-53. [PMID: 11516410 DOI: 10.1016/s0006-8993(01)02434-9] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Slices of rat hippocampus were exposed to 700 MHz continuous wave radiofrequency (RF) fields (25.2-71.0 V m(-1), 5-15 min exposure) in a stripline waveguide. At low field intensities, the predominant effect on the electrically evoked field potential in CA1 was a potentiation of the amplitude of the population spike by up to 20%, but higher intensity fields could produce either increases or decreases of up to 120 and 80%, respectively, in the amplitude of the population spike. To eliminate the possibility of RF-induced artefacts due to the metal stimulating electrode, the effect of RF exposure on spontaneous epileptiform activity induced in CA3 by 4-aminopyridine (50-100 microM) was investigated. Exposure to RF fields (50.0 V m(-1)) reduced or abolished epileptiform bursting in 36% of slices tested. The maximum field intensity used in these experiments, 71.0 V m(-1), was calculated to produce a specific absorption rate (SAR) of between 0.0016 and 0.0044 W kg(-1) in the slices. Measurements with a Luxtron fibreoptic probe confirmed that there was no detectable temperature change (+/- 0.1 degrees C) during a 15 min exposure to this field intensity. Furthermore, imposed temperature changes of up to 1 degrees C failed to mimic the effects of RF exposure. These results suggest that low-intensity RF fields can modulate the excitability of hippocampal tissue in vitro in the absence of gross thermal effects. The changes in excitability may be consistent with reported behavioural effects of RF fields.
Collapse
Affiliation(s)
- J E Tattersall
- Biomedical Sciences Department, CBD Porton Down, SP4 0JQ, Salisbury, UK.
| | | | | | | | | | | | | | | |
Collapse
|
163
|
Stagg RB, Hawel LH, Pastorian K, Cain C, Adey WR, Byus CV. Effect of immobilization and concurrent exposure to a pulse-modulated microwave field on core body temperature, plasma ACTH and corticosteroid, and brain ornithine decarboxylase, Fos and Jun mRNA. Radiat Res 2001; 155:584-92. [PMID: 11260660 DOI: 10.1667/0033-7587(2001)155[0584:eoiace]2.0.co;2] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Exposure of humans and rodents to radiofrequency (RF) cell phone fields has been reported to alter a number of stress- related parameters. To study this potential relationship in more detail, tube-restrained immobilized Fischer 344 rats were exposed in the near field in a dose-dependent manner to pulse-modulated (11 packets/s) digital cell phone microwave fields at 1.6 GHz in accordance with the Iridium protocol. Core body temperatures, plasma levels of the stress-induced hormones adrenocorticotrophic hormone (ACTH) and corticosterone, and brain levels of ornithine decarboxylase (Odc), Fos and Jun mRNAs were measured as potential markers of stress responses mediated by RF radiation. We tested the effects of the loose-tube immobilization with and without prior conditioning throughout a 2-h period (required for near-field head exposure to RF fields), on core body temperature, plasma ACTH and corticosteroids. Core body temperature increased transiently (+/-0.3 degrees C) during the initial 30 min of loose-tube restraint in conditioned animals. When conditioned/tube-trained animals were followed as a function of time after immobilization, both the ACTH and corticosterone levels were increased by nearly 10-fold. For example, within 2-3 min, ACTH increased to 83.2 +/- 31.0 pg/dl, compared to 28.1 +/- 7.7 pg/dl for cage controls, reaching a maximum at 15-30 min (254.6 +/- 46.8 pg/dl) before returning to near resting levels by 120 min (31.2 +/- 10.2 pg/dl). However, when non-tube-trained animals were submitted to loose-tube immobilization, these animals demonstrated significantly higher (3-10-fold greater) hormone levels at 120 min than their tube-trained counterparts (313.5 +/- 54.8 compared to 31.2 +/- 10.2 pg/dl; corticosterone, 12.2 +/- 6.2 microg/dl compared to 37.1 +/- 6.4 microg/dl). Hormone levels in exposed animals were also compared to those in swim-stressed animals. Swimming stress also resulted in marked elevation in both ACTH and corticosterone levels, which were 10-20 fold higher (541.8 compared to 27.2-59.1 pg/dl for ACTH) and 2-5 fold higher (45.7 compared to 8.4- 20.0 microg/dl for corticosteroids) than the cage control animals. Three time-averaged brain SAR levels of 0.16, 1.6 and 5 W/ kg were tested in a single 2-h RF-field exposure to the Iridium cell phone field. When RF-exposed and sham-exposed (immobilized) animals were compared, no differences were seen in core body temperature, corticosterone or ACTH that could be attributed to near-field RF radiation. Levels of Odc, Fos and Jun mRNA were also monitored in brains of animals exposed to the RF field for 2 h, and they showed no differences from sham-exposed (loose-tube immobilized) animals that were due to RF-field exposure. These data suggest that a significant stress response, indicated by a transient increase in core body temperature, ACTH and corticosterone, occurred in animals placed in even the mild loose-tube immobilization required for near-field RF exposure employed here and in our other studies. Failure to adequately characterize and control this immobilization response with appropriate cage control animals, as described previously, could significantly mask any potential effects mediated by the RF field on these and other stress-related parameters. We conclude that the pulse-modulated digital Iridium RF field at SARs up to 5 W/kg is incapable of altering these stress-related responses. This conclusion is further supported by our use of an RF-field exposure apparatus that minimized immobilization stress; the use of conditioned/tube-trained animals and the measurement of hormonal and molecular markers after 2 h RF-field exposure when the stress-mediated effects were complete further support our conclusion.
Collapse
Affiliation(s)
- R B Stagg
- Department of Biochemistry, University of California, Riverside, CA 92521-0121, USA
| | | | | | | | | | | |
Collapse
|
164
|
Koivisto M, Haarala C, Krause CM, Revonsuo A, Laine M, Hämäläinen H. GSM phone signal does not produce subjective symptoms. Bioelectromagnetics 2001; 22:212-5. [PMID: 11255218 DOI: 10.1002/bem.41] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The influence of pulsed radiofrequency (RF) electromagnetic fields of digital GSM mobile phones (902 MHz, 217 Hz pulse modulation) on subjective symptoms or sensations in healthy subjects were studied in two single-blind experiments. The duration of the RF exposure was about 60 min in Experiment 1 and 30 min in Experiment 2. Each subject rated symptoms or sensations in the beginning of the experimental session and at the end of both the exposure and the nonexposure conditions. The symptoms rated were headache, dizziness, fatigue, itching or tingling of the skin, redness on the skin, and sensations of warmth on the skin. The results did not reveal any differences between exposure and non-exposure conditions, suggesting that a 30-60 min exposure to this RF field does not produce subjective symptoms in humans.
Collapse
Affiliation(s)
- M Koivisto
- Centre for Cognitive Neuroscience, University of Turku, Finland.
| | | | | | | | | | | |
Collapse
|
165
|
Lee TM, Ho SM, Tsang LY, Yang SH, Li LS, Chan CC, Yang SY. Effect on human attention of exposure to the electromagnetic field emitted by mobile phones. Neuroreport 2001; 12:729-31. [PMID: 11277573 DOI: 10.1097/00001756-200103260-00023] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
This study examined the effect of exposure to the electromagnetic field emitted by mobile phones on human attention. Three measures of attention were administered to 72 teenagers, 37 of whom were mobile phone users. The results showed that the mobile phone users performed better on one of the three measures of attention than did the non-mobile phone users. The results suggest that exposure to the electromagnetic field emitted by mobile phones may have a mild facilitating effect on attention functions, which is consistent with previous observations that exposure to the electromagnetic field has a facilitating effect on cognitive processing. The possibility that mobile phone users may be naturally better at multiple tasking tasks was discussed.
Collapse
Affiliation(s)
- T M Lee
- Department of Psychology, the University of Hong Kong [corrected]
| | | | | | | | | | | | | |
Collapse
|
166
|
|
167
|
García-Larrea L, Perchet C, Perrin F, Amenedo E. Interference of Cellular Phone Conversations with Visuomotor Tasks: An ERP Study. J PSYCHOPHYSIOL 2001. [DOI: 10.1027//0269-8803.15.1.14] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The use of mobile phones has been shown to increase drivers' reaction times (RTs), but whether this results from interference with attention, stimulus identification, or response production remains unclear. We recorded RTs and event-related brain potentials (ERPs) reflecting speed of stimulus processing, attentional allocation, and preparedness to respond during a visual reaction task performed with or without the concomitant use of a mobile phone, in either “hands-free” or “phone-in-hand” operating modes. As expected, maintaining a phone conversation increased RTs to visual targets, this effect being associated with complex ERP effects. Phone conversations did not appear to delay target detection times, as assessed by N2-P3 latencies, but did significantly decrease stimulus-induced alerting and attentional allocation (P3 amplitude) and interfered with motor preparation processes (readiness potential). P3 amplitude drop was identical whatever the mode of phone use, while decrease of readiness potential was progressive from the “hands-free” to the “phone-in-hand” condition. These results suggest that two mechanisms contributed to degrade performance in this experiment: first, a general decrease of attention to sensory inputs, characteristic of “dual-task” situations, probably acting through a delay in sensory-motor transfer times. This effect was independent of whether the phone was handled or “hands-free.” Conversely, the second factor was specifically sensitive to manipulation of the phone and caused a weakening of the readiness to respond with a motor act.
Collapse
Affiliation(s)
- Luis García-Larrea
- Research Unit (UPRES) EA 1880, Université Claude Bernard, Lyon, France
- Human Neurophysiology Laboratory, CERMEP, INSERM, Lyon, France
| | - Caroline Perchet
- Research Unit (UPRES) EA 1880, Université Claude Bernard, Lyon, France
| | - Fabien Perrin
- Research Unit (UPRES) EA 1880, Université Claude Bernard, Lyon, France
| | - Elena Amenedo
- Department of Clinical Psychology and Psychobiology, University of Santiago de Compostela, Galicia, Spain
| |
Collapse
|
168
|
Abstract
Recent and past work using echo-planar imaging (EPI) in pregnancy has allowed important anatomic and physiological information to be obtained, giving advantages over conventional radiological methods such as ultrasound. EPI is a quick, convenient method of measuring organ volumes. The volumetric estimates throughout gestation correlate well with known fetal weight at these gestations. Relaxation time measurements also can be made in the placenta and lungs. By combining the changes in relaxation and volume with gestation in the future, it may be possible to develop an "index of maturity." This could be used to accurately reflect lung maturation. T1 and T2 parameters in the placenta decreased with gestational age and with abnormal placentation. EPI can be used to assess perfusion in the placenta and flow in the uterine arteries because of its rapid acquisition times. These techniques have been applied to assess perfusion within the fetal brain.
Collapse
Affiliation(s)
- K R Duncan
- Nottingham University, Department of Obstetrics and Gynecology, City Hospital, United Kingdom.
| |
Collapse
|
169
|
Maier M, Blakemore C, Koivisto M. The health hazards of mobile phones. BMJ (CLINICAL RESEARCH ED.) 2000; 320:1288-9. [PMID: 10807602 PMCID: PMC1127293 DOI: 10.1136/bmj.320.7245.1288] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
170
|
Clements H, Duncan KR, Fielding K, Gowland PA, Johnson IR, Baker PN. Infants exposed to MRI in utero have a normal paediatric assessment at 9 months of age. Br J Radiol 2000; 73:190-4. [PMID: 10884733 DOI: 10.1259/bjr.73.866.10884733] [Citation(s) in RCA: 85] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Any differences in detailed paediatric assessment at 9 months of age in infants exposed to echo planar MRI in utero from 20 weeks gestation to term were investigated by performing a case controlled prospective observational study of 20 infants. They had all had serial echo planar MRI in the antenatal period and were compared with a control group born at the same time who had not. Statistical analysis employed likelihood ratios, odds ratios and 95% confidence intervals. The mothers of the control infants had a significantly higher standard of educational attainment (p = 0.005). A small but significant decrease in length (p = 0.047), and an increase in gross motor function (p = 0.023) of the fetuses exposed to echo planar imaging were demonstrated. No other significant developmental or social differences were seen between the two groups. Infants at 9 months of age did not demonstrate any gross abnormality likely to be related to exposure to echo planar MRI in utero.
Collapse
Affiliation(s)
- H Clements
- School of Human Development, University of Nottingham, UK
| | | | | | | | | | | |
Collapse
|