151
|
Johari M, Ghavimi MA, Mahmoudian H, Javadrashid R, Mirakhor Samani S, Fouladi DF. A comparable study of the diagnostic performance of orbital ultrasonography and CBCT in patients with suspected orbital floor fractures. Dentomaxillofac Radiol 2016; 45:20150311. [PMID: 27074346 DOI: 10.1259/dmfr.20150311] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES: To compare the diagnostic performance of ultrasonography and CBCT against CT in detecting orbital floor fractures. METHODS: A total of 120 orbits with clinical suspicion of isolated orbital floor fractures underwent multislice CT scanning with coronal reconstruction; orbital ultrasonography using a standard machine equipped with a 7- to 10-MHz linear transducer; and CBCT. Patients with severe head and face injuries were not included. The diagnostic performance of ultrasonography and CBCT was reported assuming conventional CT as the imaging method of choice. RESULTS: According to CT findings, fractures of the floor were present in 39 orbits. The sensitivity, specificity, positive-predictive value and negative-predictive value of ultrasonography in detecting orbital floor fractures were 87.2%, 100%, 100% and 94.2%, respectively. The corresponding values for CBCT were 97.4%, 97.5%, 95.0%, and 98.8%, respectively. Areas under the receiver operator characteristics curves of orbital floor fracture detection were 0.94 for ultrasonography and 0.98 for CBCT. CONCLUSIONS: When conventional CT cannot be performed in patients with clinically suspected orbital floor fracture and no severe or complex head and face injuries, CBCT could be used in detecting fractures as a reliable surrogate. Because of a lower sensitivity of ultrasonography, however, its use is limited in this regard.
Collapse
Affiliation(s)
- Masoumeh Johari
- 1 Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Islamic Republic of Iran
| | - Mohammad Ali Ghavimi
- 2 Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Islamic Republic of Iran
| | - Hediyeh Mahmoudian
- 1 Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Islamic Republic of Iran
| | - Reza Javadrashid
- 3 Department of Radiology, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Islamic Republic of Iran
| | - Simin Mirakhor Samani
- 4 Department of Pathology, Qazvin University of Medical Sciences, Qazvin, Islamic Republic of Iran
| | - Daniel F Fouladi
- 5 Neurosciences Research Center, Tabriz University of Medical Sciences, Tabriz, Islamic Republic of Iran
| |
Collapse
|
152
|
Seibel I, Cordini D, Hager A, Riechardt AI, Rehak M, Böker A, Böhmer D, Heufelder J, Joussen AM. Cataract development in patients treated with proton beam therapy for uveal melanoma. Graefes Arch Clin Exp Ophthalmol 2016; 254:1625-1630. [DOI: 10.1007/s00417-016-3356-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2015] [Revised: 03/19/2016] [Accepted: 04/13/2016] [Indexed: 11/28/2022] Open
|
153
|
Zhu K, Lv Y, Cheng Q, Hua J, Zeng Q. Extremely Low Frequency Magnetic Fields Do Not Induce DNA Damage in Human Lens Epithelial Cells In Vitro. Anat Rec (Hoboken) 2016; 299:688-97. [PMID: 27079842 DOI: 10.1002/ar.23312] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2015] [Revised: 10/30/2015] [Accepted: 11/26/2015] [Indexed: 11/10/2022]
Abstract
Non-ionizing radiations, e.g., radiofrequency electromagnetic fields, could induce DNA damage and oxidative stress in human lens epithelial cells (LECs) which can be early events in cataractogenesis. Extremely low frequency magnetic fields (ELF MF) as another common form of man-made electromagnetic fields has been considered as suspected human carcinogen by International Agency for Research on Cancer (IARC) and become a focus that people play more and more attentions to. This study aimed to determine whether ELF MF can induce DNA damage in cultured human LECs at a relatively low intensity. Human LECs were exposed or sham-exposed to a 50 Hz ELF MF which produced by a well-designed exposure system at the intensity of 0.4 mT. DNA damage in human LECs was examined by the phosphorylated form of histone variant H2AX (γH2AX) foci formation assay and further explored with western blot, flow cytometry, and alkaline comet assay. Immunofluorescence analysis showed that 0.4 mT ELF MF did not significantly increase γH2AX foci formation in human LECs after 2, 6, 12, 24, or 48 hr exposure. No significant differences had been detected in γH2AX expression level between the ELF MF- and sham-exposure groups, while no obvious chromosomal DNA fragmentation was detected by alkaline comet assay after ELF MF exposure. The results indicate an absence of genotoxicity in ELF MF-exposed human epithelial cells and do not support the hypothesis that environmental ELF MF might be causally led to genomic instability via chromosomal damage response processes. Neither short nor long term continuous exposure to 50 Hz ELF MF at 0.4 mT could induce DNA damage in human lens epithelial cells in vitro.
Collapse
Affiliation(s)
- Kan Zhu
- Bioelectromagnetics Laboratory, Zhejiang University School of Medicine, Hangzhou, China
| | - Ye Lv
- Department of environmental and occupational health, Hangzhou Center for Disease Control and Prevention, Hangzhou, China
| | - Qian Cheng
- Bioelectromagnetics Laboratory, Zhejiang University School of Medicine, Hangzhou, China.,Department of health monitoring, Haining Center for Disease Control and Prevention, Haining, China
| | - Jianing Hua
- Bioelectromagnetics Laboratory, Zhejiang University School of Medicine, Hangzhou, China
| | - Qunli Zeng
- Bioelectromagnetics Laboratory, Zhejiang University School of Medicine, Hangzhou, China
| |
Collapse
|
154
|
Eye lens dosimetry in anesthesiology: a prospective study. J Clin Monit Comput 2016; 31:303-308. [DOI: 10.1007/s10877-016-9857-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2016] [Accepted: 03/01/2016] [Indexed: 10/22/2022]
|
155
|
Lin CM, Yeh PT, Doyle P, Tsan YT, Chen PC. Association Between 131I Treatment for Thyroid Cancer and Risk of Receiving Cataract Surgery: A Cohort Study from Taiwan. J Nucl Med 2016; 57:836-41. [DOI: 10.2967/jnumed.115.167197] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2015] [Accepted: 01/07/2016] [Indexed: 01/22/2023] Open
|
156
|
Dauer LT, Ainsbury EA, Dynlacht J, Hoel D, Klein BEK, Mayer D, Prescott CR, Thornton RH, Vano E, Woloschak GE, Flannery CM, Goldstein LE, Hamada N, Tran PK, Grissom MP, Blakely EA. Status of NCRP Scientific Committee 1-23 Commentary on Guidance on Radiation Dose Limits for the Lens of the Eye. HEALTH PHYSICS 2016; 110:182-184. [PMID: 26717175 PMCID: PMC4697269 DOI: 10.1097/hp.0000000000000412] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Previous National Council on Radiation Protection and Measurements (NCRP) publications have addressed the issues of risk and dose limitation in radiation protection and included guidance on specific organs and the lens of the eye. NCRP decided to prepare an updated commentary intended to enhance the previous recommendations provided in earlier reports. The NCRP Scientific Committee 1-23 (SC 1-23) is charged with preparing a commentary that will evaluate recent studies on the radiation dose response for the development of cataracts and also consider the type and severity of the cataracts as well as the dose rate; provide guidance on whether existing dose limits to the lens of the eye should be changed in the United States; and suggest research needs regarding radiation effects on and dose limits to the lens of the eye. A status of the ongoing work of SC 1-23 was presented at the Annual Meeting, "Changing Regulations and Radiation Guidance: What Does the Future Hold?" The following represents a synopsis of a few main points in the current draft commentary. It is likely that several changes will be forthcoming as SC 1-23 responds to subject matter expert review and develops a final document, expected by mid 2016.
Collapse
Affiliation(s)
- Lawrence T Dauer
- *Memorial Sloan Kettering Cancer Center, New York, NY; †Public Health England, Oxford, United Kingdom; ‡Indiana University School of Medicine, Indianapolis, IN; §Medical University of South Carolina, Charleston, SC; **University of Wisconsin-Madison, Madison, WI; ††Indian Point Energy Center, Buchanan, NY; ‡‡Johns Hopkins Medicine, Bel Air, MD; §§Complutense University, Madrid, Spain; ***Northwestern University, Chicago, IL; †††U.S. Nuclear Regulatory Commission, Rockville, MD; ‡‡‡Boston University, Boston, MA; §§§Central Research Institute of Electric Power Industry, Tokyo, Japan; ****Electric Power Research Institute, Palo Alto, CA; ††††National Council on Radiation Protection and Measurements, Bethesda, MD; ‡‡‡‡Lawrence Berkeley National Laboratory, Berkeley, CA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
157
|
Marra KV, Wagley S, Kuperwaser MC, Campo R, Arroyo JG. Care of Older Adults: Role of Primary Care Physicians in the Treatment of Cataracts and Macular Degeneration. J Am Geriatr Soc 2016; 64:369-77. [PMID: 26825587 DOI: 10.1111/jgs.13927] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
This article aims to facilitate optimal management of cataracts and age-related macular degeneration (AMD) by providing information on indications, risk factors, referral guidelines, and treatments and to describe techniques to maximize quality of life (QOL) for people with irreversible vision loss. A review of PubMed and other online databases was performed for peer-reviewed English-language articles from 1980 through August 2012 on visual impairment in elderly adults. Search terms included vision loss, visual impairment, blind, low vision, QOL combined with age-related, elderly, and aging. Articles were selected that discussed vision loss in elderly adults, effects of vision impairment on QOL, and care strategies to manage vision loss in older adults. The ability of primary care physicians (PCPs) to identify early signs of cataracts and AMD in individuals at risk of vision loss is critical to early diagnosis and management of these common age-related eye diseases. PCPs can help preserve vision by issuing aptly timed referrals and encouraging behavioral modifications that reduce risk factors. With knowledge of referral guidelines for soliciting low-vision rehabilitation services, visual aids, and community support resources, PCPs can considerably increase the QOL of individuals with uncorrectable vision loss. By offering appropriately timed referrals, promoting behavioral modifications, and allocating low-vision care resources, PCPs may play a critical role in preserving visual health and enhancing the QOL for the elderly population.
Collapse
Affiliation(s)
- Kyle V Marra
- Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts.,School of Medicine, University of California at San Diego, La Jolla, California.,Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts
| | - Sushant Wagley
- Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts.,Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts.,College of Human Medicine, Michigan State University, East Lansing, Michigan
| | - Mark C Kuperwaser
- Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts.,Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts
| | - Rafael Campo
- Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
| | - Jorge G Arroyo
- Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts.,Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
158
|
Lehmann P, Boratyński Z, Mappes T, Mousseau TA, Møller AP. Fitness costs of increased cataract frequency and cumulative radiation dose in natural mammalian populations from Chernobyl. Sci Rep 2016; 6:19974. [PMID: 26814168 PMCID: PMC4728484 DOI: 10.1038/srep19974] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2015] [Accepted: 12/21/2015] [Indexed: 11/09/2022] Open
Abstract
A cataract is a clouding of the lens that reduces light transmission to the retina, and it decreases the visual acuity of the bearer. The prevalence of cataracts in natural populations of mammals, and their potential ecological significance, is poorly known. Cataracts have been reported to arise from high levels of oxidative stress and a major cause of oxidative stress is ionizing radiation. We investigated whether elevated frequencies of cataracts are found in eyes of bank voles Myodes glareolus collected from natural populations in areas with varying levels of background radiation in Chernobyl. We found high frequencies of cataracts in voles collected from different areas in Chernobyl. The frequency of cataracts was positively correlated with age, and in females also with the accumulated radiation dose. Furthermore, the number of offspring in female voles was negatively correlated with cataract severity. The results suggest that cataracts primarily develop as a function of ionizing background radiation, most likely as a plastic response to high levels of oxidative stress. It is therefore possible that the elevated levels of background radiation in Chernobyl affect the ecology and fitness of local mammals both directly through, for instance, reduced fertility and indirectly, through increased cataractogenesis.
Collapse
Affiliation(s)
- Philipp Lehmann
- Centre of Excellence in Biological Interactions Research, Department of Biological and Environmental Science, P.O. Box 35, FI-40014 University of Jyväskylä, Finland.,Department of Zoology, SE-106 91 University of Stockholm, Sweden
| | - Zbyszek Boratyński
- CIBIO/InBIO, Research Center in Biodiversity and Genetic Resources, University of Porto, 4485-661 Vairão, Portugal
| | - Tapio Mappes
- Centre of Excellence in Biological Interactions Research, Department of Biological and Environmental Science, P.O. Box 35, FI-40014 University of Jyväskylä, Finland
| | - Timothy A Mousseau
- Department of Biological Sciences, University of South Carolina, Columbia, SC 29208, USA
| | - Anders P Møller
- Laboratoire d'Ecologie, Systématique et Evolution, CNRS UMR 8079, Université Paris-Sud, Bâtiment 362, F-91405 Orsay Cedex, France
| |
Collapse
|
159
|
Markiewicz E, Barnard S, Haines J, Coster M, van Geel O, Wu W, Richards S, Ainsbury E, Rothkamm K, Bouffler S, Quinlan RA. Nonlinear ionizing radiation-induced changes in eye lens cell proliferation, cyclin D1 expression and lens shape. Open Biol 2016; 5:150011. [PMID: 25924630 PMCID: PMC4422125 DOI: 10.1098/rsob.150011] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Abstract
Elevated cataract risk after radiation exposure was established soon after the discovery of X-rays in 1895. Today, increased cataract incidence among medical imaging practitioners and after nuclear incidents has highlighted how little is still understood about the biological responses of the lens to low-dose ionizing radiation (IR). Here, we show for the first time that in mice, lens epithelial cells (LECs) in the peripheral region repair DNA double strand breaks (DSB) after exposure to 20 and 100 mGy more slowly compared with circulating blood lymphocytes, as demonstrated by counts of γH2AX foci in cell nuclei. LECs in the central region repaired DSBs faster than either LECs in the lens periphery or lymphocytes. Although DSB markers (γH2AX, 53BP1 and RAD51) in both lens regions showed linear dose responses at the 1 h timepoint, nonlinear responses were observed in lenses for EdU (5-ethynyl-2′-deoxy-uridine) incorporation, cyclin D1 staining and cell density after 24 h at 100 and 250 mGy. After 10 months, the lens aspect ratio was also altered, an indicator of the consequences of the altered cell proliferation and cell density changes. A best-fit model demonstrated a dose-response peak at 500 mGy. These data identify specific nonlinear biological responses to low (less than 1000 mGy) dose IR-induced DNA damage in the lens epithelium.
Collapse
Affiliation(s)
- Ewa Markiewicz
- School of Biological and Biomedical Sciences, University of Durham, Durham DH1 3LE, UK
| | - Stephen Barnard
- Public Health England, Centre for Radiation, Chemical & Environmental Hazards, Chilton, Didcot, Oxon OX11 0RQ, UK
| | - Jackie Haines
- Public Health England, Centre for Radiation, Chemical & Environmental Hazards, Chilton, Didcot, Oxon OX11 0RQ, UK
| | - Margaret Coster
- Public Health England, Centre for Radiation, Chemical & Environmental Hazards, Chilton, Didcot, Oxon OX11 0RQ, UK
| | - Orry van Geel
- School of Biological and Biomedical Sciences, University of Durham, Durham DH1 3LE, UK Faculty of Science, KU Leuven, Kasteelpark Arenberg 11, Leuven 3001, Belgium
| | - Weiju Wu
- School of Biological and Biomedical Sciences, University of Durham, Durham DH1 3LE, UK Biophysical Sciences Institute, University of Durham, Durham DH1 3LE, UK
| | - Shane Richards
- School of Biological and Biomedical Sciences, University of Durham, Durham DH1 3LE, UK
| | - Elizabeth Ainsbury
- Public Health England, Centre for Radiation, Chemical & Environmental Hazards, Chilton, Didcot, Oxon OX11 0RQ, UK
| | - Kai Rothkamm
- Public Health England, Centre for Radiation, Chemical & Environmental Hazards, Chilton, Didcot, Oxon OX11 0RQ, UK
| | - Simon Bouffler
- Public Health England, Centre for Radiation, Chemical & Environmental Hazards, Chilton, Didcot, Oxon OX11 0RQ, UK
| | - Roy A Quinlan
- School of Biological and Biomedical Sciences, University of Durham, Durham DH1 3LE, UK Biophysical Sciences Institute, University of Durham, Durham DH1 3LE, UK
| |
Collapse
|
160
|
Lu JY, Zheng J, Zhang WZ, Huang BT. Flattening Filter-Free Beams in Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy for Sinonasal Cancer. PLoS One 2016; 11:e0146604. [PMID: 26734731 PMCID: PMC4703390 DOI: 10.1371/journal.pone.0146604] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2015] [Accepted: 12/18/2015] [Indexed: 02/05/2023] Open
Abstract
PURPOSE To evaluate the dosimetric impacts of flattening filter-free (FFF) beams in intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) for sinonasal cancer. METHODS For fourteen cases, IMRT and VMAT planning was performed using 6-MV photon beams with both conventional flattened and FFF modes. The four types of plans were compared in terms of target dose homogeneity and conformity, organ-at-risk (OAR) sparing, number of monitor units (MUs) per fraction, treatment time and pure beam-on time. RESULTS FFF beams led to comparable target dose homogeneity, conformity, increased number of MUs and lower doses to the spinal cord, brainstem and normal tissue, compared with flattened beams in both IMRT and VMAT. FFF beams in IMRT resulted in improvements by up to 5.4% for sparing of the contralateral optic structures, with shortened treatment time by 9.5%. However, FFF beams provided comparable overall OAR sparing and treatment time in VMAT. With FFF mode, VMAT yielded inferior homogeneity and superior conformity compared with IMRT, with comparable overall OAR sparing and significantly shorter treatment time. CONCLUSIONS Using FFF beams in IMRT and VMAT is feasible for the treatment of sinonasal cancer. Our results suggest that the delivery mode of FFF beams may play an encouraging role with better sparing of contralateral optic OARs and treatment efficiency in IMRT, but yield comparable results in VMAT.
Collapse
Affiliation(s)
- Jia-Yang Lu
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, Guangdong, China
| | - Jing Zheng
- Department of Laboratory, Shantou Central Hospital, Affiliated Shantou Hospital of Sun Yat-sen University, Shantou, Guangdong, China
| | - Wu-Zhe Zhang
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, Guangdong, China
| | - Bao-Tian Huang
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, Guangdong, China
- * E-mail:
| |
Collapse
|
161
|
Meyer HS, Meyer B. Perspective on Ionizing Radiation Exposure to Neurosurgery Residents in the Modern Era. World Neurosurg 2015; 88:649-650. [PMID: 26608387 DOI: 10.1016/j.wneu.2015.11.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2015] [Accepted: 11/05/2015] [Indexed: 11/17/2022]
Affiliation(s)
- Hanno S Meyer
- Department of Neurosurgery, Technical University of Munich, Munich, Germany
| | - Bernhard Meyer
- Department of Neurosurgery, Technical University of Munich, Munich, Germany.
| |
Collapse
|
162
|
Belyy YA, Tereshchenko AV, Romanko YS, Abakushina EV, Gretchaninov VB. [Triggering factors and pathogenesis of radiation cataract]. Vestn Oftalmol 2015; 131:97-101. [PMID: 26489128 DOI: 10.17116/oftalma2015131497-101] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Cataract is one of the most common eye diseases in the world. Many factors, including genetic, metabolic, nutritional, and environmental, are involved in its formation. It is necessary to know main causal agents and cellular mechanism of cataractogenesis. The tissue of the lens is considered radiosensitive, thus, lens opacities are possible late effects of exposure to ionizing radiation. The use of medical radiation for both diagnostic and therapeutic purposes grows worldwide. At the same time, there continues to be much confusion regarding the actual threshold dose of radiation exposure for cataract formation. Eye safety and the risk of cataract development are not entirely clear. However, with an ever-widening range of interventional procedures, one should take attempts to reduce the risk for radiation cataract.
Collapse
Affiliation(s)
- Yu A Belyy
- Kaluga Branch of the Academician S.N. Fyodorov IRTC 'Eye Microsurgery', Ministry of Health of the Russian Federation, 5 Svyatoslava Fedorova St., Kaluga, Russian Federation, 248007
| | - A V Tereshchenko
- Kaluga Branch of the Academician S.N. Fyodorov IRTC 'Eye Microsurgery', Ministry of Health of the Russian Federation, 5 Svyatoslava Fedorova St., Kaluga, Russian Federation, 248007
| | - Yu S Romanko
- Medical radiological research center, Ministry of Health of the Russian Federation, 4 Koroleva St., Obninsk, Russian Federation, 249036
| | - E V Abakushina
- Medical radiological research center, Ministry of Health of the Russian Federation, 4 Koroleva St., Obninsk, Russian Federation, 249036
| | - V B Gretchaninov
- Kaluga Branch of the Academician S.N. Fyodorov IRTC 'Eye Microsurgery', Ministry of Health of the Russian Federation, 5 Svyatoslava Fedorova St., Kaluga, Russian Federation, 248007
| |
Collapse
|
163
|
McKeown SR, Hatfield P, Prestwich RJD, Shaffer RE, Taylor RE. Radiotherapy for benign disease; assessing the risk of radiation-induced cancer following exposure to intermediate dose radiation. Br J Radiol 2015; 88:20150405. [PMID: 26462717 PMCID: PMC4984935 DOI: 10.1259/bjr.20150405] [Citation(s) in RCA: 67] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2015] [Revised: 10/01/2015] [Accepted: 10/12/2015] [Indexed: 12/14/2022] Open
Abstract
Most radiotherapy (RT) involves the use of high doses (>50 Gy) to treat malignant disease. However, low to intermediate doses (approximately 3-50 Gy) can provide effective control of a number of benign conditions, ranging from inflammatory/proliferative disorders (e.g. Dupuytren's disease, heterotopic ossification, keloid scarring, pigmented villonodular synovitis) to benign tumours (e.g. glomus tumours or juvenile nasopharyngeal angiofibromas). Current use in UK RT departments is very variable. This review identifies those benign diseases for which RT provides good control of symptoms with, for the most part, minimal side effects. However, exposure to radiation has the potential to cause a radiation-induced cancer (RIC) many years after treatment. The evidence for the magnitude of this risk comes from many disparate sources and is constrained by the small number of long-term studies in relevant clinical cohorts. This review considers the types of evidence available, i.e. theoretical models, phantom studies, epidemiological studies, long-term follow-up of cancer patients and those treated for benign disease, although many of the latter data pertain to treatments that are no longer used. Informative studies are summarized and considered in relation to the potential for development of a RIC in a range of key tissues (skin, brain etc.). Overall, the evidence suggests that the risks of cancer following RT for benign disease for currently advised protocols are small, especially in older patients. However, the balance of risk vs benefit needs to be considered in younger adults and especially if RT is being considered in adolescents or children.
Collapse
Affiliation(s)
| | - Paul Hatfield
- Leeds Cancer Centre, St James's University Hospital, Leeds, UK
| | | | - Richard E Shaffer
- St Luke's Cancer Centre, Royal Surrey County Hospital, Guildford, UK
| | - Roger E Taylor
- College of Medicine, Swansea University, South West Cancer Centre, Swansea, UK
| |
Collapse
|
164
|
Radiation-Induced Cataractogenesis: A Critical Literature Review for the Interventional Radiologist. Cardiovasc Intervent Radiol 2015; 39:151-60. [DOI: 10.1007/s00270-015-1207-z] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Accepted: 08/24/2015] [Indexed: 10/23/2022]
|
165
|
Evaluation of a 345 nm Femtosecond Laser for Corneal Surgery with Respect to Intraocular Radiation Hazard. PLoS One 2015; 10:e0137638. [PMID: 26361228 PMCID: PMC4567343 DOI: 10.1371/journal.pone.0137638] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2015] [Accepted: 08/19/2015] [Indexed: 01/03/2023] Open
Abstract
PURPOSE We report our findings from a preclinical safety study designed to assess potential side effects of corneal ultraviolet femtosecond laser treatment on lens and retina. METHODS Refractive lenticules (-5 dpt) with a diameter of 6 mm were created in the right cornea of eight Dutch Belted rabbits. Radiant exposure was 0.5 J/cm² in two animals and 18 J/cm² in six animals. The presence of lens opacities was assessed prior to and up to six months following laser application using Scheimpflug images (Pentacam, Oculus) and backscatter analysis (Opacity Lensmeter 702, Interzeag). Ganzfeld flash and flicker electroretinogram (ERG) recordings were obtained from both eyes prior to and up to six weeks following laser application. At the study endpoint, retinas were examined by light microscopy. RESULTS Independent of energy dose applied, no cataract formation could be observed clinically or with either of the two objective methods used. No changes in ERG recordings over time and no difference between treated and untreated eye were detected. Histologically, retinal morphology was preserved and retinal pigment epithelium as well as photoreceptor inner and outer segments appeared undamaged. Quantitative digital image analysis did not reveal cell loss in inner or outer nuclear layers. CONCLUSIONS Our analysis confirms theoretical considerations suggesting that ultraviolet femtosecond laser treatment of the cornea is safe for intraocular tissues. Transmitted light including stray light induces no photochemical effects in lens or retina at energy levels much higher than required for the clinical purpose. These conclusions cannot be applied to eyes with pre-existing retinal damage, as these may be more vulnerable to light.
Collapse
|
166
|
[Eye lens radiation exposure during ureteroscopy with and without a face protection shield: Investigations on a phantom model]. Urologe A 2015; 55:364-9. [PMID: 26228592 DOI: 10.1007/s00120-015-3921-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
BACKGROUND AND OBJECTIVES Eye lens radiation exposure during radiologically-guided endoscopic procedures may result in radiation-induced cataracts; therefore, we investigated the ocular radiation exposure during ureteroscopy on a phantom model. MATERIALS AND METHODS Using an Alderson phantom model and eye lens dosimeters, we measured the ocular radiation exposure depending on the number of X-ray images and on the duration of fluoroscopic imaging. The measurements were done with and without using a face protection shield. RESULTS We could demonstrate that a significant ocular radiation exposure can occur, depending on the number of X-ray images and on the duration time of fluoroscopy. Eye lens doses up to 0.025 mSv were recorded even using modern digital X-ray systems. Using face protection shields this ocular radiation exposure can be reduced to a minimum. CONCLUSION The International Commission on Radiological Protection (ICRP) recommendations of a mean eye lens dosage of 20 mSv/year may be exceeded during repeated ureteroscopy by a high volume surgeon. Using a face protection shield, the eye lens dose during ureteroscopy could be reduced to a minimum in a phantom model. Further investigations will show whether these results can be transferred to real life ureteroscopic procedures.
Collapse
|
167
|
Assessment of dose and DNA damages in individuals exposed to low dose and low dose rate ionizing radiations during computed tomography imaging. MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS 2015; 789-790:1-6. [DOI: 10.1016/j.mrgentox.2015.05.008] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2015] [Revised: 05/09/2015] [Accepted: 05/18/2015] [Indexed: 10/23/2022]
|
168
|
Frampton G, Harris P, Cooper K, Lotery A, Shepherd J. The clinical effectiveness and cost-effectiveness of second-eye cataract surgery: a systematic review and economic evaluation. Health Technol Assess 2015; 18:1-205, v-vi. [PMID: 25405576 DOI: 10.3310/hta18680] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Elective cataract surgery is the most commonly performed surgical procedure in the NHS. In bilateral cataracts, the eye with greatest vision impairment from cataract is operated on first. First-eye surgery can improve vision and quality of life. However, it is unclear whether or not cataract surgery on the second eye provides enough incremental benefit to be considered clinically effective and cost-effective. OBJECTIVE To conduct a systematic review of clinical effectiveness and analysis of cost-effectiveness of second-eye cataract surgery in England and Wales, based on an economic model informed by systematic reviews of cost-effectiveness and quality of life. DATA SOURCES Twelve electronic bibliographic databases, including MEDLINE, EMBASE, Web of Science, The Cochrane Library and the Centre for Reviews and Dissemination databases were searched from database inception to April 2013, with searches updated in July 2013. Reference lists of relevant publications were also checked and experts consulted. REVIEW METHODS Two reviewers independently screened references, extracted and checked data from the included studies and appraised their risk of bias. Based on the review of cost-effectiveness, a de novo economic model was developed to estimate the cost-effectiveness of second-eye surgery in bilateral cataract patients. The model is based on changes in quality of life following second-eye surgery and includes post-surgical complications. RESULTS Three randomised controlled trials (RCTs) of clinical effectiveness, three studies of cost-effectiveness and 10 studies of health-related quality of life (HRQoL) met the inclusion criteria for the systematic reviews and, where possible, were used to inform the economic analysis. Heterogeneity of studies precluded meta-analyses, and instead data were synthesised narratively. The RCTs assessed visual acuity, contrast sensitivity, stereopsis and several measures of HRQoL. Improvements in binocular visual acuity and contrast sensitivity were small and unlikely to be of clinical significance, but stereopsis was improved to a clinically meaningful extent following second-eye surgery. Studies did not provide evidence that second-eye surgery significantly affected HRQoL, apart from an improvement in the mental health component of HRQoL in one RCT. In the model, second-eye surgery generated 0.68 incremental quality-adjusted life-years with an incremental cost-effectiveness ratio of £1964. Model results were most sensitive to changes in the utility gain associated with second-eye surgery, but otherwise robust to changes in parameter values. The probability that second-eye surgery is cost-effective at willingness-to-pay thresholds of £10,000 and £20,000 is 100%. LIMITATIONS Clinical effectiveness studies were all conducted more than 9 years ago. Patients had good vision pre surgery which may not represent all patients eligible for second-eye surgery. For some vision-related patient-reported outcomes and HRQoL measures, thresholds for determining important clinical effects are either unclear or have not been determined. CONCLUSIONS Second-eye cataract surgery is generally cost-effective based on the best available data and under most assumptions. However, more up-to-date data are needed. A well-conducted RCT that reflects current populations and enables the estimation of health state utility values would be appropriate. Guidance is required on which vision-related, patient-reported outcomes are suitable for assessing effects of cataract surgery in the NHS and how these measures should be interpreted clinically. STUDY REGISTRATION This project is registered as PROSPERO CRD42013004211. FUNDING This project was funded by the National Institute for Health Research Health Technology Assessment programme.
Collapse
Affiliation(s)
- Geoff Frampton
- Southampton Health Technology Assessments Centre (SHTAC), University of Southampton, Southampton, UK
| | - Petra Harris
- Southampton Health Technology Assessments Centre (SHTAC), University of Southampton, Southampton, UK
| | - Keith Cooper
- Southampton Health Technology Assessments Centre (SHTAC), University of Southampton, Southampton, UK
| | - Andrew Lotery
- Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton, UK
| | - Jonathan Shepherd
- Southampton Health Technology Assessments Centre (SHTAC), University of Southampton, Southampton, UK
| |
Collapse
|
169
|
Rehani MM. Eye dose assessment and management: overview. RADIATION PROTECTION DOSIMETRY 2015; 165:276-278. [PMID: 25813481 DOI: 10.1093/rpd/ncv048] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Some publications have shown that Hp(0.07) or even Hp(10) can be used as good operational quantities for X-rays in view of difficulties with Hp(3). With increasing awareness, there is tendency to use whatever dosimeter is available with correction factor to estimate eye lens dose. The best position for an eye lens dosimeter has been reported to be at the side of the head nearest to the radiation source, close to the eye. Recent studies have reported eye doses with cone beam CT (CBCT) both for patients and staff, and there are many papers reporting eye lens doses to staff in nuclear medicine. To minimise the dose to eyes, the user can take advantage of a feature of CBCT of projections acquired over an angular span of 180° plus cone angle of the X-ray tube and with tube under scan arcs.
Collapse
Affiliation(s)
- M M Rehani
- Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
170
|
Bolch WE, Dietze G, Petoussi-Henss N, Zankl M. Dosimetric models of the eye and lens of the eye and their use in assessing dose coefficients for ocular exposures. Ann ICRP 2015; 44:91-111. [PMID: 25816263 DOI: 10.1177/0146645314562320] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Based upon recent epidemiological studies of ocular exposure, the Main Commission of the International Commission on Radiological Protection (ICRP) in ICRP Publication 118 states that the threshold dose for radiation-induced cataracts is now considered to be approximately 0.5 Gy for both acute and fractionated exposures. Consequently, a reduction was also recommended for the occupational annual equivalent dose to the lens of the eye from 150 mSv to 20 mSv, averaged over defined periods of 5 years. To support ocular dose assessment and optimisation, Committee 2 included Annex F within ICRP Publication 116 . Annex F provides dose coefficients - absorbed dose per particle fluence - for photon, electron, and neutron irradiation of the eye and lens of the eye using two dosimetric models. The first approach uses the reference adult male and female voxel phantoms of ICRP Publication 110. The second approach uses the stylised eye model of Behrens et al., which itself is based on ocular dimensional data given in Charles and Brown. This article will review the data and models of Annex F with particular emphasis on how these models treat tissue regions thought to be associated with stem cells at risk.
Collapse
Affiliation(s)
- W E Bolch
- University of Florida, Gainesville, FL, USA
| | | | | | - M Zankl
- Helmholtz Zentrum Munchen, Germany
| |
Collapse
|
171
|
Bajwa SJS, Kaur J. Risk and safety concerns in anesthesiology practice: The present perspective. Anesth Essays Res 2015; 6:14-20. [PMID: 25885495 PMCID: PMC4173431 DOI: 10.4103/0259-1162.103365] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Newer developments and advancements in anesthesiology, surgical, and medical fields have widened the functional scope of anesthesiologist thus increasing his professional responsibilities and obligations. While at workplace, anesthesiologist is exposed to a wide array of potential hazards that can be detrimental to his overall health. Numerous risks and safety concerns have been mentioned in the literature, but the magnitude of challenges in anesthesiology practice are far greater than those cited and anticipated. Many times these challenging situations are unavoidable and the attending anesthesiologist has to deal with them on an individual basis. These hazards not only affect the general health but can be extremely threatening in various other ways that can increase the potential risks of morbidity and mortality. This article is an attempt to bring a general awareness among anesthesia fraternity about the various health hazards associated with anesthesia practice. Also, a genuine attempt has been made to enumerate the various preventive methods and precautions that should be adopted to make practice of anesthesiology safe and smooth.
Collapse
Affiliation(s)
- Sukhminder Jit Singh Bajwa
- Department of Anaesthesiology and Intensive Care, Gian Sagar Medical College and Hospital, Ram Nagar, Banur, Punjab, India
| | - Jasbir Kaur
- Department of Anaesthesiology and Intensive Care, Gian Sagar Medical College and Hospital, Ram Nagar, Banur, Punjab, India
| |
Collapse
|
172
|
Müller WU. Current discussions of DDREF, cataracts, circulatory diseases and dose limits. RADIATION PROTECTION DOSIMETRY 2015; 164:34-37. [PMID: 25313174 DOI: 10.1093/rpd/ncu311] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Although more than a century of radiation research has provided a lot of insight into radiation risk, there are still fields that need clarification. This is particularly true for the low dose range, meaning doses up to ∼100 mSv. One can detect biological effects in that dose range, but it is unclear whether these biological effects like mutations or chromosomal aberrations translate into health effects like cancer, cataracts or circulatory diseases. Thus, for radiation protection purposes, assumptions have to made that must be reappraised on the basis of new findings from time to time. Affected by new insights are currently the DDREF (dose and dose-rate effectiveness factor), cataracts and circulatory diseases. If the new findings are very convincing, dose limits have to be changed at short notice. If there are only weak indications, stability of the radiation protection system is more important than changing limits all the time.
Collapse
Affiliation(s)
- Wolfgang-Ulrich Müller
- Institut für Medizinische Strahlenbiologie, Universitätsklinikum Essen, Essen D45122, Germany
| |
Collapse
|
173
|
Sonier M, Wronski M, Yeboah C. Evaluation of lens dose from anterior electron beams: comparison of Pinnacle and Gafchromic EBT3 film. J Appl Clin Med Phys 2015; 17:304-314. [PMID: 27074448 PMCID: PMC5874807 DOI: 10.1120/jacmp.v17i2.5713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2015] [Revised: 10/29/2015] [Accepted: 10/23/2015] [Indexed: 11/23/2022] Open
Abstract
Lens dose is a concern during the treatment of facial lesions with anterior electron beams. Lead shielding is routinely employed to reduce lens dose and minimize late complications. The purpose of this work is twofold: 1) to measure dose pro-files under large-area lead shielding at the lens depth for clinical electron energies via film dosimetry; and 2) to assess the accuracy of the Pinnacle treatment planning system in calculating doses under lead shields. First, to simulate the clinical geometry, EBT3 film and 4 cm wide lead shields were incorporated into a Solid Water phantom. With the lead shield inside the phantom, the film was positioned at a depth of 0.7 cm below the lead, while a variable thickness of solid water, simulating bolus, was placed on top. This geometry was reproduced in Pinnacle to calculate dose profiles using the pencil beam electron algorithm. The measured and calculated dose profiles were normalized to the central-axis dose maximum in a homogeneous phantom with no lead shielding. The resulting measured profiles, functions of bolus thickness and incident electron energy, can be used to estimate the lens dose under various clinical scenarios. These profiles showed a minimum lead margin of 0.5 cm beyond the lens boundary is required to shield the lens to ≤ 10% of the dose maximum. Comparisons with Pinnacle showed a consistent overestimation of dose under the lead shield with discrepancies of ~ 25% occur-ring near the shield edge. This discrepancy was found to increase with electron energy and bolus thickness and decrease with distance from the lead edge. Thus, the Pinnacle electron algorithm is not recommended for estimating lens dose in this situation. The film measurements, however, allow for a reasonable estimate of lens dose from electron beams and for clinicians to assess the lead margin required to reduce the lens dose to an acceptable level.
Collapse
Affiliation(s)
- Marcus Sonier
- Sunnybrook Health Sciences Centre Odette Cancer Centre.
| | | | | |
Collapse
|
174
|
Lens dose in routine head CT: comparison of different optimization methods with anthropomorphic phantoms. AJR Am J Roentgenol 2015; 204:117-23. [PMID: 25539246 DOI: 10.2214/ajr.14.12763] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of this study was to study different optimization methods for reducing eye lens dose in head CT. MATERIALS AND METHODS Two anthropomorphic phantoms were scanned with a routine head CT protocol for evaluation of the brain that included bismuth shielding, gantry tilting, organ-based tube current modulation, or combinations of these techniques. Highsensitivity metal oxide semiconductor field effect transistor dosimeters were used to measure local equivalent doses in the head region. The relative changes in image noise and contrast were determined by ROI analysis. RESULTS The mean absorbed lens doses varied from 4.9 to 19.7 mGy and from 10.8 to 16.9 mGy in the two phantoms. The most efficient method for reducing lens dose was gantry tilting, which left the lenses outside the primary radiation beam, resulting in an approximately 75% decrease in lens dose. Image noise decreased, especially in the anterior part of the brain. The use of organ-based tube current modulation resulted in an approximately 30% decrease in lens dose. However, image noise increased as much as 30% in the posterior and central parts of the brain. With bismuth shields, it was possible to reduce lens dose as much as 25%. CONCLUSION Our results indicate that gantry tilt, when possible, is an effective method for reducing exposure of the eye lenses in CT of the brain without compromising image quality. Measurements in two different phantoms showed how patient geometry affects the optimization. When lenses can only partially be cropped outside the primary beam, organ-based tube current modulation or bismuth shields can be useful in lens dose reduction.
Collapse
|
175
|
Sulieman A, Alzimami K, Habeeballa B, Osman H, Abdelaziz I, Sassi SA, Sam AK. Evaluation of occupational and patient radiation doses in orthopedic surgery. Appl Radiat Isot 2015; 100:65-9. [PMID: 25557979 DOI: 10.1016/j.apradiso.2014.11.020] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2014] [Revised: 11/07/2014] [Accepted: 11/24/2014] [Indexed: 10/24/2022]
Abstract
This study intends to measure the radiation dose to patients and staff during (i) Dynamic Hip Screw (DHS) and (ii) Dynamic Cannula Screw (DCS) and to evaluate entrance surface Air kerma (ESAK) dose and organ doses and effective doses. Calibrated Thermoluminescence dosimeters (TLD-GR200A) were used. The mean patients' doses were 0.46mGy and 0.07mGy for DHS and DCS procedures, respectively. The mean staff doses at the thyroid and chest were 4.69mGy and 1.21mGy per procedure. The mean organ and effective dose for patients and staff were higher in DHS compared to DCS. Orthopedic surgeons were exposed to unnecessary radiation doses due to the lack of protection measures. The radiation dose per hip procedure is within the safety limit and less than the previous studies.
Collapse
Affiliation(s)
- A Sulieman
- Radiology and Medical Imaging Department, College of Applied Medical Sciences, Salman bin Abdulaziz University, P.O. Box 422, Alkharj, Kingdom of Saudi Arabia; College of Medical Radiologic Sciences, Sudan University of Science and Technology, P.O. Box 1908, Khartoum, Sudan.
| | - K Alzimami
- Radiological Sciences Department, College of Applied Medical Sciences, King Saud University, P.O. Box 10219, Riyadh 11433, Saudi Arabia
| | - B Habeeballa
- College of Medical Radiologic Sciences, Sudan University of Science and Technology, P.O. Box 1908, Khartoum, Sudan
| | - H Osman
- Radiology Department, College of Applied Medical Science, Taif University, Taif, Saudi Arabia
| | - I Abdelaziz
- College of Medical Radiologic Sciences, Sudan University of Science and Technology, P.O. Box 1908, Khartoum, Sudan
| | - S A Sassi
- Department of Medical Physics, Prince Sultan Medical City, Riyadh, Saudi Arabia
| | - A K Sam
- Radiation safety institute, Sudan Atomic Energy Comission, Khartoum, Sudan; Radiometrics Section, International Atomic Energy Agency Environment Laboratories, 4, Quai Antoine 1er, 98000 Monaco
| |
Collapse
|
176
|
Ciraj-Bjelac O, Rehani MM. Eye dosimetry in interventional radiology and cardiology: current challenges and practical considerations. RADIATION PROTECTION DOSIMETRY 2014; 162:329-337. [PMID: 24262928 DOI: 10.1093/rpd/nct291] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Interventional radiology and cardiology are areas with high potential for risk to eye lens. Accurate assessment of eye dose is one of the most important aspects of correlating doses with observed lens opacities among workers in interventional suites and ascertaining compliance with regulatory limits. The purpose of this paper is to review current approaches and opportunities in eye dosimetry and assess challenges in particular in accuracy and practicality. The possible approaches include practical dosimetry using passive dosemeters or active dosemeters with obvious advantage of active dosimetry. When neither of these is available, other approaches are based on either retrospective dose assessment using scatter radiation dose levels or correlations between patient dose indices and eye doses to the operators. In spite of all uncertainties and variations, estimation of eye dose from patient dose can be accepted as a compromise. Future challenges include development of practical methods for regular monitoring of individual eye doses and development of better techniques to estimate eye dose from measurements at some reference points.
Collapse
Affiliation(s)
- O Ciraj-Bjelac
- Vinca Institute of Nuclear Science, University of Belgrade, M.P. Alasa 12, Vinca, Belgrade, Serbia
| | - M M Rehani
- International Atomic Energy Agency (formerly) and European Society of Radiology (ESR), Vienna, Austria
| |
Collapse
|
177
|
Magee JS, Martin CJ, Sandblom V, Carter MJ, Almén A, Cederblad Å, Jonasson P, Lundh C. Derivation and application of dose reduction factors for protective eyewear worn in interventional radiology and cardiology. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2014; 34:811-823. [PMID: 25332300 DOI: 10.1088/0952-4746/34/4/811] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Doses to the eyes of interventional radiologists and cardiologists could exceed the annual limit of 20 mSv proposed by the International Commission on Radiological Protection. Lead glasses of various designs are available to provide protection, but standard eye dosemeters will not take account of the protection they provide. The aim of this study has been to derive dose reduction factors (DRFs) equal to the ratio of the dose with no eyewear, divided by that when lead glasses are worn. Thirty sets of protective eyewear have been tested in x-ray fields using anthropomorphic phantoms to simulate the patient and clinician in two centres. The experiments performed have determined DRFs from simulations of interventional procedures by measuring doses to the eyes of the phantom representing the clinician, using TLDs in Glasgow, Scotland and with an electronic dosemeter in Gothenburg, Sweden. During interventional procedures scattered x-rays arising from the patient will be incident on the head of the clinician from below and to the side. DRFs for x-rays incident on the front of lead glasses vary from 5.2 to 7.6, while values for orientations similar to those used in the majority of clinical practice are between 1.4 and 5.2. Specialised designs with lead glass side shields or of a wraparound style with angled lenses performed better than lead glasses based on the design of standard spectacles. Results suggest that application of a DRF of 2 would provide a conservative factor that could be applied to personal dosemeter measurements to account for the dose reduction provided by any type of lead glasses provided certain criteria relating to design and consistency of use are applied.
Collapse
Affiliation(s)
- Jill S Magee
- Health Physics, Gartnavel Royal Hospital, Glasgow, G12 0XH, Scotland, UK
| | | | | | | | | | | | | | | |
Collapse
|
178
|
Aerts AM, Impens NREN, Baatout S, Benotmane MA, Camps J, Dabin JM, Derradji H, Grosche B, Horemans N, Jourdain JR, Moreels M, Perko T, Quintens R, Repussard J, Rühm W, Schneider T, Struelens L, Hardeman F. Joint research towards a better radiation protection-highlights of the Fifth MELODI Workshop. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2014; 34:931-56. [PMID: 25431966 DOI: 10.1088/0952-4746/34/4/931] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
MELODI is the European platform dedicated to low-dose radiation risk research. From 7 October through 10 October 2013 the Fifth MELODI Workshop took place in Brussels, Belgium. The workshop offered the opportunity to 221 unique participants originating from 22 countries worldwide to update their knowledge and discuss radiation research issues through 118 oral and 44 poster presentations. In addition, the MELODI 2013 workshop was reaching out to the broader radiation protection community, rather than only the low-dose community, with contributions from the fields of radioecology, emergency and recovery preparedness, and dosimetry. In this review, we summarise the major scientific conclusions of the workshop, which are important to keep the MELODI strategic research agenda up-to-date and which will serve to establish a joint radiation protection research roadmap for the future.
Collapse
Affiliation(s)
- A M Aerts
- Institute for Environment, Health and Safety, Belgian Nuclear Research Centre (SCK•CEN), Mol, Belgium
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
179
|
Outcomes of primary lymphoma of the ocular adnexa (orbital lymphoma) treated with radiotherapy. Clin Oncol (R Coll Radiol) 2014; 27:153-9. [PMID: 25455843 DOI: 10.1016/j.clon.2014.10.002] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2014] [Revised: 09/16/2014] [Accepted: 09/24/2014] [Indexed: 12/27/2022]
Abstract
AIMS Low-grade ocular adnexal lymphoma is a rare disease and often treated with local radiotherapy to varying doses. Most previously reported studies have a very heterogeneous patient population and treatments. We report the outcomes from a 10 year cohort of patients at our institution treated with primary radiation therapy. MATERIALS AND METHODS We analysed a retrospective case series of patients with stage IE low-grade ocular adnexal lymphoma including a review of case notes, histological reports and radiotherapy charts. We assessed local and distant tumour control and relapse rates in addition to toxicity. Disease-free survival was estimated using the Kaplan-Meier method. RESULTS In total, 81 patients and 85 orbits were treated with primary radiotherapy to a median dose of 30 Gy in 15 fractions over 3 weeks. Seventy-nine per cent were treated with standard MV external beam radiotherapy to the whole orbit and 21% with a lens-sparing technique. The median follow-up was 4.4 years (range 0.2-10.4). Local control rates were 100%, with 5% of patients experiencing disease relapse elsewhere. No patients died from lymphoma. Cumulative acute toxicity rates were 51% (mainly erythema and conjunctivitis) and late toxicity rates were 8% (mainly cataract). The lens-sparing technique was associated with a significant reduction in cataract rate (P = 0.013) and an increase in acute toxicity (P < 0.001). CONCLUSIONS This study has shown excellent local control rates and acceptable toxicity from the treatment of stage IE low-grade ocular adnexal lymphoma with localised radiotherapy to a median dose of 30 Gy in 15 fractions over 3 weeks.
Collapse
|
180
|
Efficacy of a Radiation Absorbing Shield in Reducing Dose to the Interventionalist During Peripheral Endovascular Procedures: A Single Centre Pilot Study. Cardiovasc Intervent Radiol 2014; 38:573-8. [DOI: 10.1007/s00270-014-0997-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2014] [Accepted: 08/07/2014] [Indexed: 10/24/2022]
|
181
|
Arii T, Uchino S, Kubo Y, Kiyama S, Uezono S. Radiation exposure to anaesthetists during endovascular procedures. Anaesthesia 2014; 70:47-50. [DOI: 10.1111/anae.12841] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/29/2014] [Indexed: 11/26/2022]
Affiliation(s)
- T. Arii
- Department of Anaesthesiology; The Jikei University School of Medicine; Tokyo Japan
| | - S. Uchino
- Department of Anaesthesiology; The Jikei University School of Medicine; Tokyo Japan
| | - Y. Kubo
- Department of Anaesthesiology; The Jikei University School of Medicine; Tokyo Japan
| | - S. Kiyama
- Department of Anaesthesiology; The Jikei University School of Medicine; Tokyo Japan
| | - S. Uezono
- Department of Anaesthesiology; The Jikei University School of Medicine; Tokyo Japan
| |
Collapse
|
182
|
Inaba Y, Chida K, Kobayashi R, Kaga Y, Zuguchi M. Fundamental study of a real-time occupational dosimetry system for interventional radiology staff. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2014; 34:N65-N71. [PMID: 25119299 DOI: 10.1088/0952-4746/34/3/n65] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Real-time monitoring of the radiation doses received by interventional radiology (IR) staff has become highly desirable. However, occupational doses are rarely measured in real time, due to the lack of a feasible method for use in IR. Recently, the i2 system by RaySafe™ has been introduced to measure occupational exposure in IR in real time. The i2 system consists of several personal dosimeters (PDs) and a base station with a display and computer interfacing. We evaluated the fundamental performance (dose linearity, dose-rate dependence, angular dependence, batch uniformity and reproducibility) of the i2 system. The dose linearity of the i2 was excellent (R(2) = 1.00) The i2 exhibited slight dose-rate dependence (~20%) at very high dose rates (250 mGy h(-1)). Little angular dependence (within 20%) was observed between 0° and ±45°, in either the vertical or horizontal direction. We also found that the PD was highly sensitive (about 200%) at angles behind it, e.g. 180°. However, this backscattered radiation is not a problem, in general, due to the placement of the i2 sensor (PD) on the lead apron. We conclude that the i2 system facilitates accurate real-time monitoring and management of occupational doses during IR.
Collapse
Affiliation(s)
- Yohei Inaba
- Course of Radiological Technology, Health Sciences, Tohoku University Graduate School of Medicine, 2-1 Seiryo, Aoba, Sendai, Miyagi 980-8575, Japan
| | | | | | | | | |
Collapse
|
183
|
Tang FR, Loke WK. Molecular mechanisms of low dose ionizing radiation-induced hormesis, adaptive responses, radioresistance, bystander effects, and genomic instability. Int J Radiat Biol 2014; 91:13-27. [DOI: 10.3109/09553002.2014.937510] [Citation(s) in RCA: 87] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
184
|
Caracappa PF, Rhodes A, Fiedler D. Multi-resolution voxel phantom modeling: a high-resolution eye model for computational dosimetry. Phys Med Biol 2014; 59:5261-75. [DOI: 10.1088/0031-9155/59/18/5261] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
185
|
The Use of Cone Beam Computed Tomography in the Postoperative Assessment of Orbital Wall Fracture Reconstruction. J Craniofac Surg 2014; 25:1150-4. [DOI: 10.1097/scs.0000000000000747] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
186
|
Kennedy AR. Biological Effects of Space Radiation and Development of Effective Countermeasures. LIFE SCIENCES IN SPACE RESEARCH 2014; 1:10-43. [PMID: 25258703 PMCID: PMC4170231 DOI: 10.1016/j.lssr.2014.02.004] [Citation(s) in RCA: 89] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
As part of a program to assess the adverse biological effects expected from astronaut exposure to space radiation, numerous different biological effects relating to astronaut health have been evaluated. There has been major focus recently on the assessment of risks related to exposure to solar particle event (SPE) radiation. The effects related to various types of space radiation exposure that have been evaluated are: gene expression changes (primarily associated with programmed cell death and extracellular matrix (ECM) remodeling), oxidative stress, gastrointestinal tract bacterial translocation and immune system activation, peripheral hematopoietic cell counts, emesis, blood coagulation, skin, behavior/fatigue (including social exploration, submaximal exercise treadmill and spontaneous locomotor activity), heart functions, alterations in biological endpoints related to astronaut vision problems (lumbar puncture/intracranial pressure, ocular ultrasound and histopathology studies), and survival, as well as long-term effects such as cancer and cataract development. A number of different countermeasures have been identified that can potentially mitigate or prevent the adverse biological effects resulting from exposure to space radiation.
Collapse
Affiliation(s)
- Ann R Kennedy
- Department of Radiation Oncology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104-6072
| |
Collapse
|
187
|
Ainsbury EA, Bouffler S, Cocker M, Gilvin P, Holt E, Peters S, Slack K, Williamson A. Public Health England survey of eye lens doses in the UK medical sector. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2014; 34:15-29. [PMID: 24270156 DOI: 10.1088/0952-4746/34/1/15] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
The ICRP has recently recommended that the occupational exposure limit for the lens of the eye be reduced to 20 mSv in a year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv. There has been concern amongst some groups of individuals, particularly interventional cardiologists and radiologists as well as relevant professional bodies, that implementation of these recommendations into UK law will adversely affect working patterns. However, despite a number of informative European studies, there is currently little UK dosimetry data available upon which judgements can effectively be based. In order to address this knowledge gap, Public Health England has carried out a small, targeted survey of UK lens doses to medical staff undertaking procedures likely to involve the highest levels of radiation exposure. Two out of a total of 61 individuals surveyed had projected annual doses which could be close to 20 mSv, measured outside lead glasses. Use of protective equipment was generally good; however, lead glasses were only used by 9 participants. The results of this survey suggest that compliance with the ICRP recommendations is likely to be possible for most individuals in the UK medical sector.
Collapse
|
188
|
Abstract
Everyone is exposed to natural and manmade ionizing radiation that can originate from sources in the environment and in medical and occupational settings. There is notable variation, however, among individuals and across populations in the types of sources of radiation and in the frequency, level, and duration of exposure. Adverse health effects associated with radiation exposure have been known for decades, and ionizing radiation exposure has been linked with a broad range of different types of cancer and benign neoplasms as well as birth defects, reproductive effects, and diseases of the circulatory, hematologic, and neurologic systems. Our present understanding of radiation-related health risks derives primarily from multidisciplinary health risk (epidemiologic) studies that provide the key information on radiation-associated health outcomes, quantify radiation-related disease risks, and enhance understanding of mechanisms of radiation-related disease pathogenesis. Such information is central to quantifying risks in relation to benefits; addressing public concerns, including societal and clinical needs in relation to radiation exposure; and providing the database needed for establishing recommendations for radiation protection. Because of the importance of determining risks compared to benefits for all situations where exposure to ionizing radiation might result, it is useful for planning new health risks studies to categorize exposed populations according to the sources and types of radiation. This paper describes a wide range of populations exposed to radiation and the motivation and key methodological criteria that drive the rationale and priority of studying such populations. Also, discussed are alternative methods for evaluating radiation-related health risks in these populations, with a major focus on epidemiologic approaches. This paper concludes with a short summary of major highlights from radiation epidemiologic research and important unanswered questions.Introduction of Exposed Populations (Video 1:29, http://links.lww.com/HP/A22).
Collapse
Affiliation(s)
- Steven L Simon
- *Division of Cancer Epidemiology and Genetics, National CancerInstitute, National Institutes of Health, 6120 Executive Blvd, Bethesda, MD
| | | |
Collapse
|
189
|
Heusch P, Kröpil P, Buchbender C, Aissa J, Lanzman RS, Heusner TA, Ewen K, Antoch G, Fürst G. Radiation exposure of the radiologist's eye lens during CT-guided interventions. Acta Radiol 2014; 55:86-90. [PMID: 23884839 DOI: 10.1177/0284185113493222] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND In the past decade the number of computed tomography (CT)-guided procedures performed by interventional radiologists have increased, leading to a significantly higher radiation exposure of the interventionalist's eye lens. Because of growing concern that there is a stochastic effect for the development of lens opacification, eye lens dose reduction for operators and patients should be of maximal interest. PURPOSE To determine the interventionalist's equivalent eye lens dose during CT-guided interventions and to relate the results to the maximum of the recommended equivalent dose limit. MATERIAL AND METHODS During 89 CT-guided interventions (e.g. biopsies, drainage procedures, etc.) measurements of eye lens' radiation doses were obtained from a dedicated dosimeter system for scattered radiation. The sensor of the personal dosimeter system was clipped onto the side of the lead glasses which was located nearest to the CT gantry. After the procedure, radiation dose (µSv), dose rate (µSv/min) and the total exposure time (s) were recorded. RESULTS For all 89 interventions, the median total exposure lens dose was 3.3 µSv (range, 0.03-218.9 µSv) for a median exposure time of 26.2 s (range, 1.1-94.0 s). The median dose rate was 13.9 µSv/min (range, 1.1-335.5 µSv/min). CONCLUSION Estimating 50-200 CT-guided interventions per year performed by one interventionalist, the median dose of the eye lens of the interventional radiologist does not exceed the maximum of the ICRP-recommended equivalent eye lens dose limit of 20 mSv per year.
Collapse
Affiliation(s)
- Philipp Heusch
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University of Dusseldorf, Dusseldorf, Germany
| | - Patric Kröpil
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University of Dusseldorf, Dusseldorf, Germany
| | - Christian Buchbender
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University of Dusseldorf, Dusseldorf, Germany
| | - Joel Aissa
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University of Dusseldorf, Dusseldorf, Germany
| | - Rotem S Lanzman
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University of Dusseldorf, Dusseldorf, Germany
| | - Till A Heusner
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University of Dusseldorf, Dusseldorf, Germany
| | - Klaus Ewen
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University of Dusseldorf, Dusseldorf, Germany
| | - Gerald Antoch
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University of Dusseldorf, Dusseldorf, Germany
| | - Günther Fürst
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University of Dusseldorf, Dusseldorf, Germany
| |
Collapse
|
190
|
Abstract
The atomic bomb and other studies have established with certainty that moderate-to-high doses of radiation cause many types of solid cancer and leukemia. Moving down the dose range to the vicinity of 100-200 mSv, the risks become fuzzy and then unknown at low doses on the order of 10-20 mSv. Nor have low-dose experimental studies provided definitive answers: some have suggested there may be adverse biological effects in the range of 5-50 mSv, while others support a "no risk" interpretation. Epidemiologic data contain intrinsic "noise" (variation by known and unknown factors related to genetics, lifestyle, other environmental exposures, sociodemographics, diagnostic accuracy, etc.) so are generally too insensitive to provide compelling answers in the low-dose range. However, there have been recent provocative reports regarding risk from relatively low-dose occupational and medical radiation exposures that warrant careful consideration. Summaries of the largest studies with low-dose or low dose-rate radiation exposure provide suggestive evidence of risk for solid cancer and stronger evidence for leukemia risk. Recently, interest in health endpoints other than cancer also has risen sharply, in particular the degree of cardiovascular and cataract risk following doses under 1 Sv. Data regarding cardiovascular disease are limited and fuzzy, with suggestions of inconsistencies, and the risk at low doses is essentially unknown. The evidence of cataract risk after low dose-rate exposures among those conducting interventional medical radiological procedures is becoming strong. The magnitude of radiation impacts on human health requires fuller documentation, especially for low-dose or low dose-rate exposures. From the epidemiologic vantage point, this will require longer observation of existing irradiated cohorts and development of new informative cohorts, improved accuracy in dose assessments, more attention to confounding variables, and more biosamples from irradiated groups to enable translational radiobiological studies. Introduction of Radiation Impacts on Human Health (Video 2:02, http://links.lww.com/HP/A35).
Collapse
Affiliation(s)
- Roy E Shore
- *Radiation Effects Research Foundation, 5-2 Hijiyama Park, Minami-ku, Hiroshima 732-0815, Japan
| |
Collapse
|
191
|
The risk of cataract associated with repeated head and neck CT studies: a nationwide population-based study. AJR Am J Roentgenol 2013; 201:626-30. [PMID: 23971456 DOI: 10.2214/ajr.12.9652] [Citation(s) in RCA: 70] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
OBJECTIVE Medical radiation-induced cataracts, especially those resulting from head and neck CT studies, are an issue of concern. The current study aimed to determine the risk of cataract associated with repeated radiation exposure from head and neck CT. MATERIALS AND METHODS This study used information from a random sample of 2 million persons enrolled in the nationally representative Taiwan National Health Insurance Research Database. Exposed cases consisted of patients with head and neck tumor 10-50 years old who underwent at least one CT between 2000 and 2009. The nonexposed control group was composed of subjects who were never exposed to CT studies but who were matched by time of enrollment, age, sex, history of coronary artery disease, hypertension, and diabetes. RESULTS There were 2776 patients in the exposed group and 27,761 matched subjects in the nonexposed group. The exposed group had higher overall incidence of cataracts (0.97% vs 0.72%; adjusted hazard ratio [HR], 1.76; 95% CI, 1.18-2.63). Further stratifying the number of CT studies in the exposed group into one or two, three or four, and five or more revealed that cataract incidence increased gradually with increasing frequency of CT studies (0.79%, 0.93%, and 1.45%, respectively) (p=0.001, adjusted for trend). Radiation exposure due to repeated head and neck CT studies was independently associated with an increased risk of developing cataracts when the cumulative CT exposure frequency involved more than four studies (adjusted HR, 2.12; 95% CI, 1.09-4.14). CONCLUSION Repeated exposure to head and neck CT is significantly associated with increased risk of cataract.
Collapse
|
192
|
Gualdrini G, Ferrari P, Tanner R. Fluence to Hp(3) conversion coefficients for neutrons from thermal to 15 MeV. RADIATION PROTECTION DOSIMETRY 2013; 157:278-290. [PMID: 23671134 DOI: 10.1093/rpd/nct126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
The recent statement on tissue reactions issued by the International Commission on Radiological Protection in April 2011 recommends a very significant reduction in the equivalent dose annual limit for the eye lens from 150 to 20 mSv y(-1); this has stimulated a lot of interest in eye lens dosimetry in the radiation protection community. Until now no conversion coefficients were available for the operational quantity Hp(3) for neutrons. The scope of the present work was to extend previous evaluations of H*(10) and Hp(10) performed at the PTB in 1995 to provide also Hp(3) data for neutrons. The present work is also intended to complete the studies carried out on photons during the last 4 y within the European Union-funded ORAMED (optimisation of radiation protection for medical staff) project.
Collapse
Affiliation(s)
- G Gualdrini
- ENEA-IRP, Radiation Protection Institute, 16 via dei colli, Bologna (BO) 40136, Italy
| | | | | |
Collapse
|
193
|
Farah J, Struelens L, Dabin J, Koukorava C, Donadille L, Jacob S, Schnelzer M, Auvinen A, Vanhavere F, Clairand I. A correlation study of eye lens dose and personal dose equivalent for interventional cardiologists. RADIATION PROTECTION DOSIMETRY 2013; 157:561-569. [PMID: 23858492 DOI: 10.1093/rpd/nct180] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
This paper presents the dosimetry part of the European ELDO project, funded by the DoReMi Network of Excellence, in which a method was developed to estimate cumulative eye lens doses for past practices based on personal dose equivalent values, H(p)(10), measured above the lead apron at several positions at the collar, chest and waist levels. Measurement campaigns on anthropomorphic phantoms were carried out in typical interventional settings considering different tube projections and configurations, beam energies and filtration, operator positions and access routes and using both mono-tube and biplane X-ray systems. Measurements showed that eye lens dose correlates best with H(p)(10) measured on the left side of the phantom at the level of the collar, although this correlation implicates high spreads (41 %). Nonetheless, for retrospective dose assessment, H(p)(10) records are often the only option for eye dose estimates and the typically used chest left whole-body dose measurement remains useful.
Collapse
Affiliation(s)
- J Farah
- Laboratoire de Dosimétrie des Rayonnements Ionisants, IRSN - Institut de Radioprotection et de Sûreté Nucléaire, PRP-HOM/SDE/LDRI BP-17, 92262 Fontenay-aux-Roses Cedex, France
| | | | | | | | | | | | | | | | | | | |
Collapse
|
194
|
Hoffmann W, Meiboom MF, Weitmann K, Terschüren C, von Boetticher H. Influence of age, sex and calendar year on lifetime accumulated red bone marrow dose from diagnostic radiation exposure. PLoS One 2013; 8:e78027. [PMID: 24244286 PMCID: PMC3823920 DOI: 10.1371/journal.pone.0078027] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2013] [Accepted: 09/08/2013] [Indexed: 11/19/2022] Open
Abstract
Our aim is to evaluate the relevance of different factors influencing lifetime accumulated red bone marrow dose, such as calendar year, age and sex. The lifetime dose was estimated for controls interviewed in person (N = 2811, 37.5% women) of the population-based representative Northern Germany Leukemia and Lymphoma Study. Data were assessed in standardized computer-assisted personal interviews. The calculation of doses is based on a comprehensive quantification model including calendar year, sex, kind of examination, and technical development. In multivariate regression models the annual red bone marrow dose was analyzed depending on age, sex and calendar year to consider simultaneously temporal changes in radiologic practice and individual risk factors. While the number of examinations continuously rises over time, the dose shows two peaks around 1950 and after 1980. Men are exposed to higher doses than woman. Until 1970 traditional examinations like conventional and mass screening examinations caused the main dose. They were then replaced by technically advanced examinations mainly computed tomography and cardiac catheter. The distribution of the red bone marrow dose over lifetime depends highly on the technical standards and radiation protection survey. To a lesser extent it is influenced by age and sex of the subjects. Thus epidemiological studies concerning the assessment of radiation exposure should consider the calendar year in which the examination was conducted.
Collapse
Affiliation(s)
- Wolfgang Hoffmann
- Institute for Community Medicine, Department Epidemiology of Health Care and Community Health, University Medicine Greifswald, Greifswald, Germany
- * E-mail:
| | | | - Kerstin Weitmann
- Institute for Community Medicine, Department Epidemiology of Health Care and Community Health, University Medicine Greifswald, Greifswald, Germany
| | - Claudia Terschüren
- Institute for Community Medicine, Department Epidemiology of Health Care and Community Health, University Medicine Greifswald, Greifswald, Germany
| | - Heiner von Boetticher
- Institute for Radiology and Academy of Radiation Protection, Hospital Links der Weser, Bremen, Germany
| |
Collapse
|
195
|
Efficacy of Radiation Safety Glasses in Interventional Radiology. Cardiovasc Intervent Radiol 2013; 37:1149-55. [DOI: 10.1007/s00270-013-0766-0] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2013] [Accepted: 09/27/2013] [Indexed: 10/26/2022]
|
196
|
Gelesko S, Markiewicz MR, Bell RB. Responsible and Prudent Imaging in the Diagnosis and Management of Facial Fractures. Oral Maxillofac Surg Clin North Am 2013; 25:545-60. [DOI: 10.1016/j.coms.2013.07.001] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
197
|
Söderman M, Holmin S, Andersson T, Palmgren C, Babić D, Hoornaert B. Image Noise Reduction Algorithm for Digital Subtraction Angiography: Clinical Results. Radiology 2013; 269:553-60. [DOI: 10.1148/radiol.13121262] [Citation(s) in RCA: 86] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
198
|
Little MP. A review of non-cancer effects, especially circulatory and ocular diseases. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2013; 52:435-449. [PMID: 23903347 PMCID: PMC4074546 DOI: 10.1007/s00411-013-0484-7] [Citation(s) in RCA: 84] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2013] [Accepted: 07/14/2013] [Indexed: 05/30/2023]
Abstract
There is a well-established association between high doses (>5 Gy) of ionizing radiation exposure and damage to the heart and coronary arteries, although only recently have studies with high-quality individual dosimetry been conducted that would enable quantification of this risk adjusting for concomitant chemotherapy. The association between lower dose exposures and late occurring circulatory disease has only recently begun to emerge in the Japanese atomic bomb survivors and in various occupationally exposed cohorts and is still controversial. Excess relative risks per unit dose in moderate- and low-dose epidemiological studies are somewhat variable, possibly a result of confounding and effect modification by well-known (but unobserved) risk factors. Radiation doses of 1 Gy or more are associated with increased risk of posterior subcapsular cataract. Accumulating evidence from the Japanese atomic bomb survivors, Chernobyl liquidators, US astronauts, and various other exposed groups suggests that cortical cataracts may also be associated with ionizing radiation, although there is little evidence that nuclear cataracts are radiogenic. The dose-response appears to be linear, although modest thresholds (of no more than about 0.6 Gy) cannot be ruled out. A variety of other non-malignant effects have been observed after moderate/low-dose exposure in various groups, in particular respiratory and digestive disease and central nervous system (and in particular neuro-cognitive) damage. However, because these are generally only observed in isolated groups, or because the evidence is excessively heterogeneous, these associations must be treated with caution.
Collapse
Affiliation(s)
- Mark P Little
- Radiation Epidemiology Branch, National Cancer Institute, 9609 Medical Center Drive MSC 9778, Bethesda, MD, 20892-9778, USA,
| |
Collapse
|
199
|
Brisco J, Fuller K, Lee N, Andrew D. Cone beam computed tomography for imaging orbital trauma--image quality and radiation dose compared with conventional multislice computed tomography. Br J Oral Maxillofac Surg 2013; 52:76-80. [PMID: 24139635 DOI: 10.1016/j.bjoms.2013.09.011] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2013] [Accepted: 09/16/2013] [Indexed: 11/25/2022]
Abstract
We compared the image quality and radiation dose to the lens of the eye in patients with suspected orbital fractures who were imaged using cone beam computed tomography (CBCT) or conventional multislice computed tomography (CT). Although CBCT has a lower radiation dose than conventional CT, it is not known whether the image quality is comparable for diagnostic purposes. We identified fractures of the orbit (floor or roof, or both) in 6/10 patients who were scanned using CBCT and in 5/10 patients who were scanned using multislice CT (orbital floor and medial wall). Impingement of the rectus muscle on fracture lines was identified with both techniques, but retro-orbital haemorrhage was detected only on multislice CT. The mean radiation dose to the lens of the eye was 42% lower (range 23-53, SD 10) for CBCT than for multislice CT (p<0.001), and the effective dose (a measure of the risk of developing a radiation-induced cancer) was also significantly lower. CBCT can therefore be used to diagnose orbital fractures, and is associated with a significantly lower radiation dose than multislice CT.
Collapse
Affiliation(s)
- Jessica Brisco
- Medical Physics, Weston Park Hospital, Whitham Road, Sheffield S10 2SJ, United Kingdom.
| | - Karen Fuller
- Medical Physics, Weston Park Hospital, Whitham Road, Sheffield S10 2SJ, United Kingdom.
| | - Nicholas Lee
- Charles Clifford Dental Hospital, Wellesley Road, Sheffield S10 2SZ, United Kingdom.
| | - David Andrew
- Unit of Oral & Maxillofacial Surgery, School of Clinical Dentistry, Claremont Crescent, Sheffield S10 2TA, United Kingdom.
| |
Collapse
|
200
|
Hypofractionated stereotactic photon radiotherapy of posteriorly located choroidal melanoma with five fractions at ten Gy--clinical results after six years of experience. Radiother Oncol 2013; 108:342-7. [PMID: 24044800 DOI: 10.1016/j.radonc.2013.08.004] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2012] [Revised: 06/06/2013] [Accepted: 08/07/2013] [Indexed: 11/21/2022]
Abstract
PURPOSE To evaluate long-term safety and efficacy of hypofractionated stereotactic photon radiotherapy with 5 five fractions at 10 Gy each in patients with centrally located choroidal melanoma. MATERIALS AND METHODS Ninety-one patients with centrally located choroidal melanoma were treated stereotactically at a linear accelerator with 6 MV photon beams with 5 fractions at 10 Gy each. Examinations were performed at baseline and every 3 months in the first 2 years, then every 6 months until 5 years and yearly thereafter. Median follow-up was 37.8 months (IQR 19.2-49.9). They included visual acuity assessment, routine ophthalmological examinations with fundoscopy, echography for measurement of tumor dimensions, medical examinations and, if necessary, fluorescein angiography. RESULTS Initial tumor base diameters, height and volume were 11.20mm (IQR 9.10-13.70), 9.80 mm (IQR 7.80-11.70), 4.53 mm (IQR 3.33-6.43) and 253.8mm(3) (IQR 127.5-477.0). Local tumor control and eye retention rates were 97.7% and 86.4% after 5 years, respectively. Eight patients developed metastatic disease and 3 of them died due to metastatic disease during the follow-up period. Median visual acuity decreased from 0.67 initially to 0.05 at the last individual follow-up (p<0.001). The most common toxicities (any grade) were radiation retinopathy (n=39), optic neuropathy (n=32), radiogenic cataract (n=21), neovascular glaucoma (n=15) and dry eye syndrome (n=10). The 5 year probabilities to remain free of these side effects (any grade) were 26.0%, 45.4%, 55.4%, 72.6% and 80.5%, respectively. The most important prognostic factors for toxicities were the largest tumor base diameter, tumor height and tumor distance to the optic disk. CONCLUSION Hypofractionated stereotactic photon radiotherapy with a total dose of 50 Gy delivered in 5 fractions is a highly effective treatment option in patients with centrally located choroidal melanoma and has a moderate toxicity profile.
Collapse
|