201
|
Barnes M, Pomare D, Doebrich M, Standen TS, Wolf J, Greer P, Simpson J. Insensitivity of machine log files to MLC leaf backlash and effect of MLC backlash on clinical dynamic MLC motion: An experimental investigation. J Appl Clin Med Phys 2022; 23:e13660. [PMID: 35678793 PMCID: PMC9512360 DOI: 10.1002/acm2.13660] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Revised: 05/09/2022] [Accepted: 05/11/2022] [Indexed: 12/02/2022] Open
Abstract
Purpose Multi‐leaf‐collimator (MLC) leaf position accuracy is important for accurate dynamic radiotherapy treatment plan delivery. Machine log files have become widely utilized for quality assurance (QA) of such dynamic treatments. The primary aim is to test the sensitivity of machine log files in comparison to electronic portal imaging device (EPID)‐based measurements to MLC position errors caused by leaf backlash. The secondary aim is to investigate the effect of MLC leaf backlash on MLC leaf motion during clinical dynamic plan delivery. Methods The sensitivity of machine log files and two EPID‐based measurements were assessed via a controlled experiment, whereby the length of the “T” section of a series of 12 MLC leaf T‐nuts in a Varian Millennium MLC for a Trilogy C‐series type linac was reduced by sandpapering the top of the “T” to introduce backlash. The built‐in machine MLC leaf backlash test as well as measurements for two EPID‐based dynamic MLC positional tests along with log files were recorded pre‐ and post‐T‐nut modification. All methods were investigated for sensitivity to the T‐nut change by assessing the effect on measured MLC leaf positions. A reduced version of the experiment was repeated on a TrueBeam type linac with Millennium MLC. Results No significant differences before and after T‐nut modification were detected in any of the log file data. Both EPID methods demonstrated sensitivity to the introduced change at approximately the expected magnitude with a strong dependence observed with gantry angle. EPID‐based data showed MLC positional error in agreement with the micrometer measured T‐nut length change to 0.07 ± 0.05 mm (1 SD) using the departmental routine QA test. Backlash results were consistent between linac types. Conclusion Machine log files appear insensitive to MLC position errors caused by MLC leaf backlash introduced via the T‐nut. The effect of backlash on clinical MLC motions is heavily gantry angle dependent.
Collapse
Affiliation(s)
- Michael Barnes
- Department of Radiation Oncology, Calvary Mater Hospital Newcastle, Newcastle, New South Wales, Australia.,School of Mathematical and Physical Sciences, University of Newcastle, Newcastle, New South Wales, Australia
| | - Dennis Pomare
- Department of Radiation Oncology, Calvary Mater Hospital Newcastle, Newcastle, New South Wales, Australia
| | - Marcus Doebrich
- Department of Radiation Oncology, Calvary Mater Hospital Newcastle, Newcastle, New South Wales, Australia
| | - Therese S Standen
- Department of Radiation Oncology, Calvary Mater Hospital Newcastle, Newcastle, New South Wales, Australia
| | - Joshua Wolf
- Department of Radiation Oncology, Calvary Mater Hospital Newcastle, Newcastle, New South Wales, Australia.,Icon Cancer Centre Maitland, Maitland Private Hospital, Maitland, New South Wales, Australia
| | - Peter Greer
- Department of Radiation Oncology, Calvary Mater Hospital Newcastle, Newcastle, New South Wales, Australia.,School of Mathematical and Physical Sciences, University of Newcastle, Newcastle, New South Wales, Australia
| | - John Simpson
- Department of Radiation Oncology, Calvary Mater Hospital Newcastle, Newcastle, New South Wales, Australia.,School of Mathematical and Physical Sciences, University of Newcastle, Newcastle, New South Wales, Australia
| |
Collapse
|
202
|
Zhang H, Lu W, Cui H, Li Y, Yi X. Assessment of Statistical Process Control Based DVH Action Levels for Systematic Multi-Leaf Collimator Errors in Cervical Cancer RapidArc Plans. Front Oncol 2022; 12:862635. [PMID: 35664736 PMCID: PMC9157499 DOI: 10.3389/fonc.2022.862635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 04/19/2022] [Indexed: 11/18/2022] Open
Abstract
Background In the patient-specific quality assurance (QA), DVH is a critical clinically relevant parameter that is finally used to determine the safety and effectiveness of radiotherapy. However, a consensus on DVH-based action levels has not been reached yet. The aim of this study is to explore reasonable DVH-based action levels and optimal DVH metrics in detecting systematic MLC errors for cervical cancer RapidArc plans. Methods In this study, a total of 148 cervical cancer RapidArc plans were selected and measured with COMPASS 3D dosimetry system. Firstly, the patient-specific QA results of 110 RapidArc plans were retrospectively reviewed. Then, DVH-based action limits (AL) and tolerance limits (TL) were obtained by statistical process control. Secondly, systematic MLC errors were introduced in 20 RapidArc plans, generating 380 modified plans. Then, the dose difference (%DE) in DVH metrics between modified plans and original plans was extracted from measurement results. After that, the linear regression model was used to investigate the detection limits of DVH-based action levels between %DE and systematic MLC errors. Finally, a total of 180 test plans (including 162 error-introduced plans and 18 original plans) were prepared for validation. The error detection rate of DVH-based action levels was compared in different DVH metrics of 180 test plans. Results A linear correlation was found between systematic MLC errors and %DE in all DVH metrics. Based on linear regression model, the systematic MLC errors between -0.94 mm and 0.88 mm could be caught by the TL of PTV95 ([-1.54%, 1.51%]), and the systematic MLC errors between -1.00 mm and 0.80 mm could also be caught by the TL of PTVmean ([-2.06%, 0.38%]). In the validation, for original plans, PTV95 showed the minimum error detection rate of 5.56%. For error-introduced plans with systematic MLC errors more than 1mm, PTVmean showed the maximum error detection rate of 88.89%, and then was followed by PTV95 (86.67%). All the TL of DVH metrics showed a poor error detection rate in identifying error-induced plans with systematic MLC errors less than 1mm. Conclusion In 3D quality assurance of cervical cancer RapidArc plans, process-based tolerance limits showed greater advantages in distinguishing plans introduced with systematic MLC errors more than 1mm, and reasonable DVH-based action levels can be acquired through statistical process control. During DVH-based verification, main focus should be on the DVH metrics of target volume. OARs in low-dose regions were found to have a relatively higher dose sensitivity to smaller systematic MLC errors, but may be accompanied with higher false error detection rate.
Collapse
Affiliation(s)
- Hanyin Zhang
- Department of Oncology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Wenli Lu
- Department of Oncology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Haixia Cui
- Department of Oncology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Ying Li
- Department of Oncology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Xin Yi
- Department of Oncology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| |
Collapse
|
203
|
Prisciandaro J, Zoberi JE, Cohen G, Kim Y, Johnson P, Paulson E, Song W, Hwang KP, Erickson B, Beriwal S, Kirisits C, Mourtada F. AAPM Task Group Report 303 endorsed by the ABS: MRI Implementation in HDR Brachytherapy-Considerations from Simulation to Treatment. Med Phys 2022; 49:e983-e1023. [PMID: 35662032 DOI: 10.1002/mp.15713] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 04/11/2022] [Accepted: 05/05/2022] [Indexed: 11/05/2022] Open
Abstract
The Task Group (TG) on Magnetic Resonance Imaging (MRI) Implementation in High Dose Rate (HDR) Brachytherapy - Considerations from Simulation to Treatment, TG 303, was constituted by the American Association of Physicists in Medicine's (AAPM's) Science Council under the direction of the Therapy Physics Committee, the Brachytherapy Subcommittee, and the Working Group on Brachytherapy Clinical Applications. The TG was charged with developing recommendations for commissioning, clinical implementation, and on-going quality assurance (QA). Additionally, the TG was charged with describing HDR brachytherapy (BT) workflows and evaluating practical consideration that arise when implementing MR imaging. For brevity, the report is focused on the treatment of gynecologic and prostate cancer. The TG report provides an introduction and rationale for MRI implementation in BT, a review of previous publications on topics including available applicators, clinical trials, previously published BT related TG reports, and new image guided recommendations beyond CT based practices. The report describes MRI protocols and methodologies, including recommendations for the clinical implementation and logical considerations for MR imaging for HDR BT. Given the evolution from prescriptive to risk-based QA,1 an example of a risk-based analysis using MRI-based, prostate HDR BT is presented. In summary, the TG report is intended to provide clear and comprehensive guidelines and recommendations for commissioning, clinical implementation, and QA for MRI-based HDR BT that may be utilized by the medical physics community to streamline this process. This report is endorsed by the American Brachytherapy Society (ABS). This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
| | | | - Gil'ad Cohen
- Memorial Sloan-Kettering Cancer Center, New York, NY
| | | | - Perry Johnson
- University of Florida Health Proton Therapy Institute, Jacksonville, FL
| | | | | | - Ken-Pin Hwang
- The University of Texas MD Anderson Cancer Center, Houston, TX
| | | | - Sushil Beriwal
- Allegheny Health Network Cancer Institute, Pittsburgh, PA
| | | | - Firas Mourtada
- Sidney Kimmel Cancer Center at Thomas Jefferson University Hospital, Philadelphia, Pennsylvania
| |
Collapse
|
204
|
Evaluation of the clinical implementation of a tattoo-free positioning technique in breast cancer radiotherapy using ExacTrac. Phys Med 2022; 98:81-87. [DOI: 10.1016/j.ejmp.2022.04.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 02/28/2022] [Accepted: 04/27/2022] [Indexed: 11/18/2022] Open
|
205
|
Freislederer P, Batista V, Öllers M, Buschmann M, Steiner E, Kügele M, Fracchiolla F, Corradini S, de Smet M, Moura F, Perryck S, Dionisi F, Nguyen D, Bert C, Lehmann J. ESTRO-ACROP guideline on surface guided radiation therapy. Radiother Oncol 2022; 173:188-196. [PMID: 35661677 DOI: 10.1016/j.radonc.2022.05.026] [Citation(s) in RCA: 33] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 05/26/2022] [Indexed: 10/18/2022]
Abstract
Surface guidance systems enable patient positioning and motion monitoring without using ionising radiation. Surface Guided Radiation Therapy (SGRT) has therefore been widely adopted in radiation therapy in recent years, but guidelines on workflows and specific quality assurance (QA) are lacking. This ESTRO-ACROP guideline aims to give recommendations concerning SGRT roles and responsibilities and highlights common challenges and potential errors. Comprehensive guidelines for procurement, acceptance, commissioning, and QA of SGRT systems installed on computed tomography (CT) simulators, C-arm linacs, closed-bore linacs, and particle therapy treatment systems are presented that will help move to a consensus among SGRT users and facilitate a safe and efficient implementation and clinical application of SGRT.
Collapse
Affiliation(s)
- P Freislederer
- Department of Radiation Oncology, LMU University Hospital, Munich, Germany.
| | - V Batista
- Department of Radiation Oncology, Heidelberg University Hospital, Germany; Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
| | - M Öllers
- Department of Radiotherapy, MAASTRO, Maastricht, The Netherlands
| | - M Buschmann
- Department of Radiation Oncology, Medical University of Vienna/AKH Wien, Austria
| | - E Steiner
- Institute for Radiation Oncology and Radiotherapy, Landesklinikum Wiener Neustadt, Austria
| | - M Kügele
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | - F Fracchiolla
- Azienda Provinciale per i Servizi Sanitari (APSS) Protontherapy Department, Trento, Italy
| | - S Corradini
- Department of Radiation Oncology, LMU University Hospital, Munich, Germany
| | - M de Smet
- Department of Medical Physics & Instrumentation, Institute Verbeeten, Tilburg, The Netherlands
| | - F Moura
- Hospital CUF Descobertas, Department of Radiation Oncology, Lisbon, Portugal
| | - S Perryck
- Department of Radiation Oncology, University Hospital Zürich, Switzerland
| | - F Dionisi
- Department of Radiation Oncology, IRCSS Regina Elena National Cancer Institute, Rome, Italy
| | - D Nguyen
- Centre de Radiothérapie de Mâcon, France
| | - C Bert
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Germany
| | - J Lehmann
- Radiation Oncology Department, Calvary Mater Newcastle, Australia; School of Information and Physical Sciences, University of Newcastle, Australia; Institute of Medical Physics, University of Sydney, Australia
| |
Collapse
|
206
|
Accuracy Evaluation of Collapsed Cone Convolution Superposition Algorithms for the Nasopharynx Interface in the Early Stage of Nasopharyngeal Carcinoma. BIOMED RESEARCH INTERNATIONAL 2022; 2022:5227609. [PMID: 35669729 PMCID: PMC9167114 DOI: 10.1155/2022/5227609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Accepted: 05/10/2022] [Indexed: 11/18/2022]
Abstract
This study combined the use of radiation dosimeteric measurements and a custom-made anthropomorphic phantom in order to evaluate the accuracy of therapeutic dose calculations at the nasopharyngeal air-tissue interface. The doses at the nasopharyngeal air-tissue interface obtained utilizing the Pinnacle and TomoTherapy TPS, which are based on collapsed cone convolution superposition (CCCS) algorithms, were evaluated and measured under single
,
, two parallel opposed
and clinical fields for early stage of nasopharyngeal carcinoma by using EBT3, GR-200F, and TLD 100. At the air-tissue interface under a
field, the TPS dose calculation values were in good agreement with the dosimeter measurement with all differences within 3.5%. When measured the single field
, the differences between the average dose were measured at the distal interface for EBT3, GR-200F, and TLD-100 and the calculation values were -15.8%, -16.4%, and -4.9%, respectively. When using the clinical techniques such as IMRT, VMAT, and tomotherapy, the measurement results at the interface for all three techniques did not imply under dose. Small-field sizes will lead to dose overestimation at the nasopharyngeal air-tissue interface due to electronic disequilibrium when using CCCS algorithms. However, under clinical applications of multiangle irradiation, the dose errors caused by this effect were not significant.
Collapse
|
207
|
Descriptive Time Series Analysis for Downtime Prediction Using the Maintenance Data of a Medical Linear Accelerator. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12115431] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
A medical linear accelerator (LINAC) delivers high-energy X-rays or electrons to the patient’s tumor. In this study, we categorized failures and predicted downtime leading to discontinuous radiation treatment using a descriptive time series analysis of a 20-year maintenance dataset of a medical LINAC. A LINAC dataset of failure records for 359 instances was collected from 2001 to 2021. Next, we performed institution-specific seasonal autoregressive integrated moving average (ARIMA) modeling to analyze the causes of the failure categories and predict the downtime. Furthermore, we evaluated the performance of the predictive model using standard error metrics and statistical methods. Our results show that the downtime will increase by 95 h/year after 2022 and 100 h/year after 2023. The accumulated downtime in 2029 is predicted to be a maximum of 2820 h. The modeled seasonal ARIMA showed statistical significance (p < 0.001) with a residual error of σ2 (328.33 ± 9.4). In addition, the forecasting performance of the model was assessed using the mean absolute percentage error (MAPE). The failure parts where the major downtime occurred were the multileaf collimator (25.2%), gantry and couch motion part (15.4%), dosimetric part (11.7%), and computer console (10.0%). Using the development of the ARIMA model specific to our institution, the downtime is predicted to reach up to 2820 h.
Collapse
|
208
|
Price AT, Canfield C, Hugo GD, Kavanaugh JA, Henke LE, Laugeman E, Samson P, Reynolds-Kueny C, Cudney EA. Techno-Economic Feasibility Analysis of a Fully Mobile Radiation Oncology System Using Monte Carlo Simulation. JCO Glob Oncol 2022; 8:e2100284. [PMID: 35609229 PMCID: PMC9173580 DOI: 10.1200/go.21.00284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Disparities in radiation oncology (RO) can be attributed to geographic location, socioeconomic status, race, sex, and other societal factors. One potential solution is to implement a fully mobile (FM) RO system to bring radiotherapy to rural areas and reduce barriers to access. We use Monte Carlo simulation to quantify techno-economic feasibility with uncertainty, using two rural Missouri scenarios.
Collapse
Affiliation(s)
- Alex T Price
- Department of Radiation Oncology, Washington University School of Medicine in St Louis, St Louis, MO.,Department of Engineering Management and Systems Engineering, Missouri University of Science and Technology, Rolla, MO
| | - Casey Canfield
- Department of Engineering Management and Systems Engineering, Missouri University of Science and Technology, Rolla, MO
| | - Geoffrey D Hugo
- Department of Radiation Oncology, Washington University School of Medicine in St Louis, St Louis, MO
| | - James A Kavanaugh
- Department of Radiation Oncology, Washington University School of Medicine in St Louis, St Louis, MO
| | - Lauren E Henke
- Department of Radiation Oncology, Washington University School of Medicine in St Louis, St Louis, MO
| | - Eric Laugeman
- Department of Radiation Oncology, Washington University School of Medicine in St Louis, St Louis, MO
| | - Pamela Samson
- Department of Radiation Oncology, Washington University School of Medicine in St Louis, St Louis, MO
| | - Clair Reynolds-Kueny
- Department of Psychological Science, Missouri University of Science and Technology, Rolla, MO
| | | |
Collapse
|
209
|
Jean E, Lambert-Girard S, Therriault-Proulx F, Beaulieu L. External beam irradiation angle measurement using a hybrid Cerenkov-scintillation detector. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac6b79] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Accepted: 04/28/2022] [Indexed: 11/12/2022]
Abstract
Abstract
Objective. In this study, we propose a novel approach designed to take advantage of the Cerenkov light angular dependency to perform a direct measurement of an external beam irradiation angle. Approach. A Cerenkov probe composed of a 10 mm long filtered sensitive volume of clear PMMA optical fibre was built. Both filtered and raw Cerenkov signals from the transport fibre were collected through a single 1 mm diameter transport fibre. An independent plastic scintillation detector composed of 10 mm BCF12 scintillating fibre was also used for simultaneous dose measurements. A first series of measurements aimed at validating the ability to account for the Cerenkov electron energy spectrum dependency by simultaneously measuring the deposited dose, thus isolating signal variations resulting from the angular dependency. Angular calibration curve for fixed dose irradiations and incident angle measurements using electron and photon beams where also achieved. Main results. The beam nominal energy was found to have a significant impact on the shapes of the angular calibration curves. This can be linked to the electron energy spectrum dependency of the Cerenkov emission cone. Irradiation angle measurements exhibit an absolute mean error of 1.86° and 1.02° at 6 and 18 MV, respectively. Similar results were obtained with electron beams and the absolute mean error reaches 1.97°, 1.66°, 1.45° and 0.95° at 9, 12, 16 and 20 MeV, respectively. Reducing the numerical aperture of the Cerenkov probe leads to an increased angular dependency for the lowest energy while no major changes were observed at higher energy. This allowed irradiation angle measurements at 6 MeV with a mean absolute error of 4.82°. Significance. The detector offers promising perspectives as a potential tool for future quality assurance applications in radiotherapy, especially for stereotactic radiosurgery (SRS), magnetic resonance image-guided radiotherapy (MRgRT) and brachytherapy applications.
Collapse
|
210
|
Tegtmeier RC, Ferris WS, Bayouth JE, Miller JR, Culberson WS. Characterization of imaging performance of a novel helical kVCT for use in image‐guided and adaptive radiotherapy. J Appl Clin Med Phys 2022; 23:e13648. [PMID: 35570390 PMCID: PMC9194993 DOI: 10.1002/acm2.13648] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 03/30/2022] [Accepted: 04/26/2022] [Indexed: 11/27/2022] Open
Abstract
ClearRT helical kVCT imaging for the Radixact helical tomotherapy system recently received FDA approval and is available for clinical use. The system is intended to enhance image fidelity in radiation therapy treatment planning and delivery compared to the prior MV‐based onboard imaging approach. The purpose of this work was to characterize the imaging performance of this system and compare this performance with that of clinical systems used in image‐guided and/or adaptive radiotherapy (ART) or computed tomography (CT) simulation, including Radixact MVCT, TomoTherapy MVCT, Varian TrueBeam kV OBI CBCT, and the Siemens SOMATOM Definition Edge kVCT. A CT image quality phantom was scanned across clinically relevant acquisition modes for each system to evaluate image quality metrics, including noise, uniformity, contrast, spatial resolution, and CT number linearity. Similar noise levels were observed for ClearRT and Siemens Edge, whereas noise for the other systems was ∼1.5–5 times higher. Uniformity was best for Siemens Edge, whereas most scans for ClearRT exhibited a slight “cupping” or “capping” artifact. The ClearRT and Siemens Edge performed best for contrast metrics, which included low‐contrast visibility and contrast‐to‐noise ratio evaluations. Spatial resolution was best for TrueBeam and Siemens Edge, whereas the three kVCT systems exhibited similar CT number linearity. Overall, these results provide an initial indication that ClearRT image quality is adequate for image guidance in radiotherapy and sufficient for delineating anatomic structures, thus enabling its use for ART. ClearRT also showed significant improvement over MVCT, which was previously the only onboard imaging modality available on Radixact. Although the acquisition of these scans does come at the cost of additional patient dose, reported CTDI values indicate a similar or generally reduced machine output for ClearRT compared to the other systems while maintaining comparable or improved image quality overall.
Collapse
Affiliation(s)
- Riley C. Tegtmeier
- Department of Medical Physics School of Medicine and Public Health University of Wisconsin‐Madison Madison Wisconsin USA
| | - William S. Ferris
- Department of Medical Physics School of Medicine and Public Health University of Wisconsin‐Madison Madison Wisconsin USA
| | - John E. Bayouth
- Department of Human Oncology School of Medicine and Public Health University of Wisconsin‐Madison Madison Wisconsin USA
| | - Jessica R. Miller
- Department of Human Oncology School of Medicine and Public Health University of Wisconsin‐Madison Madison Wisconsin USA
| | - Wesley S. Culberson
- Department of Medical Physics School of Medicine and Public Health University of Wisconsin‐Madison Madison Wisconsin USA
| |
Collapse
|
211
|
Boudet J, Aubignac L, Beneux A, Mazoyer F, Bessieres I. Evaluation of QA software system analysis for the static picket fence test. J Appl Clin Med Phys 2022; 23:e13618. [PMID: 35570379 PMCID: PMC9278673 DOI: 10.1002/acm2.13618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 02/01/2022] [Accepted: 04/01/2022] [Indexed: 11/16/2022] Open
Abstract
Intensity modulation treatments are widely used in radiotherapy because of many known advantages. In this context, the picket fence test (PF) is a relevant test to check the Multileaf Collimator (MLC) performances. So this work compares and evaluates three analysis platforms for the PF used routinely by three different institutions. This study covers two linear accelerators (Linac) with two MLC types, a Millenium 120 MLC and Millenium 120 High Definition MLC respectively on a Varian Truebeam and Truebeam STx. Both linacs include an As 1200 portal imager (EPID). From a reference PF plan, MLC errors have been introduced to modify the slits in position or width (shifts from 0.1 to 0.5 mm on one or both banks). Then errors have been defined on the EPID to investigate detection system deviations (signal sensitivity and position variations). Finally, 110 DICOM‐RT images have been generated and analyzed by each software system. All software systems have shown good performances to quantify the position errors, even though the leaf pair identifications can be wrong in some cases regarding the analysis method considered. The slit width measurement (not calculated by all software systems) has shown good sensitivity, but some quantification difficulties have been highlighted regardless of the analysis method used. Linked to the expected accuracy of the PF test, the imager variations have demonstrated considerable influence in the results. Differences in the results and the analysis methods have been pointed out for each software system. The results can be helpful to optimize the settings of each analysis software system depending on expectations and treatment modalities of each institution.
Collapse
Affiliation(s)
- Julien Boudet
- Department of Physics Centre Georges François Leclerc Dijon France
| | - Léone Aubignac
- Department of Physics Centre Georges François Leclerc Dijon France
| | - Amandine Beneux
- Department of Physics Hospices Civils de Lyon Pierre Bénite France
| | - Frédéric Mazoyer
- Department of Radiotherapy Centre Hospitalier Annecy Genevois Epagny Metz‐Tessy France
| | - Igor Bessieres
- Department of Physics Centre Georges François Leclerc Dijon France
| |
Collapse
|
212
|
Goodall SK, Dunn L, Dunning J, Muñoz L, Rowshanfarzad P, Ebert MA. Matched linac stereotactic radiotherapy: An assessment of delivery similarity and distributive patient‐specific quality assurance feasibility. J Appl Clin Med Phys 2022; 23:e13652. [DOI: 10.1002/acm2.13652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 03/03/2022] [Accepted: 04/13/2022] [Indexed: 11/11/2022] Open
Affiliation(s)
- Simon K Goodall
- School of Physics, Mathematics, and Computing, Faculty of Engineering and Mathematical Sciences University of Western Australia Crawley Western Australia Australia
- GenesisCare Wembley Western Australia Australia
| | - Leon Dunn
- GenesisCare Fitzroy Victoria Australia
| | | | - Luis Muñoz
- GenesisCare Bedford Park South Australia Australia
- Centre for Medical Radiation Physics University of Wollongong New South Wales Australia
| | - Pejman Rowshanfarzad
- School of Physics, Mathematics, and Computing, Faculty of Engineering and Mathematical Sciences University of Western Australia Crawley Western Australia Australia
| | - Martin A Ebert
- School of Physics, Mathematics, and Computing, Faculty of Engineering and Mathematical Sciences University of Western Australia Crawley Western Australia Australia
- Department of Radiation Oncology Sir Charles Gardiner Hospital Nedlands Western Australia Australia
- 5D Clinics Perth Western Australia Australia
| |
Collapse
|
213
|
Wall PDH, Hirata E, Morin O, Valdes G, Witztum A. Prospective clinical validation of virtual patient-specific quality assurance of VMAT radiation therapy plans. Int J Radiat Oncol Biol Phys 2022; 113:1091-1102. [PMID: 35533908 DOI: 10.1016/j.ijrobp.2022.04.040] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 04/05/2022] [Accepted: 04/27/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE Performing measurement-based patient-specific quality assurance (PSQA) is recognized as a resource-intensive and time inefficient task in the radiotherapy treatment workflow. Paired with technological refinements in modern radiotherapy, research towards measurement-free PSQA has seen increased interest over the last five years. However, these efforts have not been clinically implemented or prospectively validated in the U.S. We propose a virtual QA (VQA) system and workflow to assess the safety and workload reduction of measurement-free PSQA. METHODS An XGBoost machine learning model was designed to predict PSQA outcomes of VMAT plans, represented as percent differences between the measured ion chamber point dose in a phantom and the corresponding planned dose. The final model was deployed within a web application to predict PSQA outcomes of clinical plans within an existing clinical workflow. The application also displays relevant feature importance and plan-specific distribution analyses relative to database plans for documentation and to aid physicist interpretation and evaluation. VQA predictions were prospectively validated over three months of measurements at our clinic to assess safety and efficiency gains. RESULTS Over three months, VQA predictions for 445 VMAT plans were prospectively validated at our institution. VQA predictions for these plans had a mean absolute error of 1.08 +/- 0.77%, with a maximum absolute error of 2.98%. Employing a 1% prediction threshold (i.e. plans predicted to have an absolute error of less than 1% would not require a measurement) would yield a 69.2% reduction in QA workload - saving 32.5 hours per month on average - with 81.5%/72.4%/0.81 sensitivity/specificity/AUC at a 3% clinical threshold and 100%/70%/0.93 sensitivity/specificity/AUC at a 4% clinical threshold. CONCLUSION This is the first prospective clinical implementation and validation of VQA in the U.S., which we observed to be efficient. Using a conservative threshold, VQA can substantially reduce the number of required measurements for PSQA, leading to more effective allocation of clinical resources.
Collapse
Affiliation(s)
- Phillip D H Wall
- Department of Radiation Oncology, University of California, San Francisco, USA.
| | - Emily Hirata
- Department of Radiation Oncology, University of California, San Francisco, USA
| | - Olivier Morin
- Department of Radiation Oncology, University of California, San Francisco, USA
| | - Gilmer Valdes
- Department of Radiation Oncology, University of California, San Francisco, USA
| | - Alon Witztum
- Department of Radiation Oncology, University of California, San Francisco, USA
| |
Collapse
|
214
|
Corns R, Yang K, Ross M, Bhandari S, Aryal M, Ciaccio P. A 3D star shot to determine the gantry, collimator, and couch axes positions. J Appl Clin Med Phys 2022; 23:e13623. [PMID: 35486368 PMCID: PMC9278693 DOI: 10.1002/acm2.13623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 03/02/2022] [Accepted: 04/08/2022] [Indexed: 11/09/2022] Open
Abstract
A linear accelerator has three independent axes that are nominally intersecting at the isocenter. Modern treatment techniques require the coincidence of these axes to lie within a 1‐mm diameter sphere. A solution to verify this requirement is to wrap a film on a cylindrical surface, align the cylinder to the linac's isocenter and gantry axis, and take multiple exposures of slits, rotating either the gantry, collimator, or couch between exposures. The resulting exposure pattern is the 3D equivalent of the 2D star shot and encodes sufficient information to determine each axis’ position in 3D. Moreover, this method uses a single sheet 8“x10” film, a standard film scanner, and a phantom that can be readily built in‐house, making a practical solution to this 3D‐measurement problem.
Collapse
Affiliation(s)
- Robert Corns
- Department of Radiation Oncology, Brody School of Medicine, East Carolina University, Greenville, North Carolina, USA
| | - Kaida Yang
- Department of Radiation Oncology, Brody School of Medicine, East Carolina University, Greenville, North Carolina, USA
| | - Mason Ross
- Department of Physics, East Carolina University, Greenville, North Carolina, USA
| | - Shiva Bhandari
- Department of Physics, East Carolina University, Greenville, North Carolina, USA
| | - Makunda Aryal
- Department of Physics, East Carolina University, Greenville, North Carolina, USA
| | - Peter Ciaccio
- Department of Physics, East Carolina University, Greenville, North Carolina, USA
| |
Collapse
|
215
|
Rotational effect and dosimetric impact: HDMLC vs 5-mm MLC leaf width in single isocenter multiple metastases radiosurgery with Brainlab Elements™. JOURNAL OF RADIOTHERAPY IN PRACTICE 2022. [DOI: 10.1017/s1460396922000048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Abstract
Purpose:
To analyse the impact of multileaf collimator (MLC) leaf width in multiple metastases radiosurgery (SRS) considering the target distance to isocenter and rotational displacements.
Methods:
Ten plans were optimised. The plans were created with Elements Multiple Mets SRS v2·0 (Brainlab AG, Munchen, Germany). The mean number of metastases per plan was 5 ± 2 [min 3, max 9], and the mean volume of gross tumour volume (GTV) was 1·1 ± 1·3 cc [min 0·02, max 5·1]. Planning target volume margin criterion was based on GTV-isocenter distance and target dimensions. Plans were performed using 6 MV with high-definition MLC (HDMLC) and reoptimised using 5-mm MLC (MLC-5). Plans were compared using Paddick conformity index (PCI), gradient index, monitor units , volume receiving half of prescription isodose (PIV50), maximum dose to brainstem, optic chiasm and optic nerves, and V12Gy, V10Gy and V5Gy for healthy brain were analysed. The maximum displacement due to rotational combinations was optimised by a genetic algorithm for both plans. Plans were reoptimised and compared using optimised margin.
Results:
HDMLC plans had better conformity and higher dose falloff than MLC-5 plans. Dosimetric differences were statistically significant (p < 0·05). The smaller the lesion volume, the higher the dosimetric differences between both plans. The effect of rotational displacements produced for each target in SRS was not dependent on the MLC (p > 0·05).
Conclusions:
The finer HDMLC offers dosimetric advantages compared with the MLC-5 in terms of target conformity and dose to the surrounding organs at risk. However, only dose falloff differences due to rotations depend on MLC.
Collapse
|
216
|
Tse MY, Chan WKC, Fok TC, Chiu TL, Yu SK. Dosimetric impact of phase shifts on Radixact Synchrony tracking system with patient-specific breathing patterns. J Appl Clin Med Phys 2022; 23:e13600. [PMID: 35446474 PMCID: PMC9195033 DOI: 10.1002/acm2.13600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 12/01/2021] [Accepted: 03/14/2022] [Indexed: 11/24/2022] Open
Abstract
Purpose The Synchrony tracking system of Radixact is capable of real‐time tumor tracking by building a correlation model between external light‐emitting diodes on the patient's chest and an internal marker. A phase shift between the chest wall and a lung tumor has been reported. Hence, this study focused on evaluating the accuracy of the tracking system, especially under a patient‐specific breathing pattern with respiratory phase shifts. Methods A phantom containing fiducial markers was placed on a moving platform. The intrinsic delivery accuracy was verified with a patient‐specific breathing pattern. Three patient‐specific breathing patterns were then implemented, for which phase shifts, φ, were introduced. Phase shifts with +0.3 s and +1 s were tested for dosimetric aspects, whereas ±0.3, ±0.6, and ±0.8 s shifts were used for tracking accuracy. The resultant dose distributions were analyzed by γ comparison. Dose profiles in the superior‐inferior and lateral directions were compared. Logfiles of the tracking information were extracted from the system and compared with the input breathing pattern. The root mean square (RMS) difference was used to quantify the consistency. Results When the φ value was as large as 1 s, a severe inconsistency was observed. The target was significantly underdosed, down to 89% of the originally planned dose. γ analysis revealed that the failed portion was concentrated in the target region. The RMS of the tracking difference was close to 1 mm when φ was ±0.3 s and approximately 4 mm when φ was ±0.8 s. Tracking errors increased with an increase in the degree of phase shifts. Conclusion Phase shifts between the patient chest wall and the internal target may hamper treatment delivery and jeopardize treatment using Synchrony Tracking. Hence, a larger planning target volume (PTV) may be necessary if a large phase shift is observed in a patient, especially when an external surrogate shows a lag in motion when compared with the tumor.
Collapse
Affiliation(s)
- Mei Yan Tse
- Medical Physics Department, Hong Kong Sanatorium and Hospital, Hong Kong SAR, China
| | - Wing Ki Claudia Chan
- Medical Physics Department, Hong Kong Sanatorium and Hospital, Hong Kong SAR, China
| | - Tsz Ching Fok
- Medical Physics Department, Hong Kong Sanatorium and Hospital, Hong Kong SAR, China
| | - Tin Lok Chiu
- Medical Physics Department, Hong Kong Sanatorium and Hospital, Hong Kong SAR, China
| | - Siu Ki Yu
- Medical Physics Department, Hong Kong Sanatorium and Hospital, Hong Kong SAR, China
| |
Collapse
|
217
|
Mehrens H, Nguyen T, Edward S, Hartzell S, Glenn M, Branco D, Hernandez N, Alvarez P, Molineu A, Taylor P, Kry S. The current status and shortcomings of stereotactic radiosurgery. Neurooncol Adv 2022; 4:vdac058. [PMID: 35664554 PMCID: PMC9154323 DOI: 10.1093/noajnl/vdac058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Background Stereotactic radiosurgery (SRS) is a common treatment for intracranial lesions. This work explores the state of SRS treatment delivery to characterize current treatment accuracy based on treatment parameters. Methods NCI clinical trials involving SRS rely on an end-to-end treatment delivery on a patient surrogate (credentialing phantom) from the Imaging and Radiation Oncology Core (IROC) to test their treatment accuracy. The results of 1072 SRS phantom irradiations between 2012 and 2020 were retrospectively analyzed. Univariate analysis and random forest models were used to associate irradiation conditions with phantom performance. The following categories were evaluated in terms of how they predicted outcomes: year of irradiation, TPS algorithm, machine model, energy, and delivered field size. Results Overall, only 84.6% of irradiations have met the IROC/NCI acceptability criteria. Pass rate has remained constant over time, while dose calculation accuracy has slightly improved. Dose calculation algorithm (P < .001), collimator (P = .024), and field size (P < .001) were statistically significant predictors of pass/fail. Specifically, pencil beam algorithms and cone collimators were more likely to be associated with failing phantom results. Random forest modeling identified the size of the field as the most important factor for passing or failing followed by algorithm. Conclusion Constant throughout this retrospective study, approximately 15% of institutions fail to meet IROC/NCI standards for SRS treatment. In current clinical practice, this is particularly associated with smaller fields that yielded less accurate results. There is ongoing need to improve small field dosimetry, beam modeling, and QA to ensure high treatment quality, patient safety, and optimal clinical trials.
Collapse
Affiliation(s)
- Hunter Mehrens
- Department of Outreach Physics, UT MD Anderson Cancer Center, Houston, TX
- Imaging and Radiation Oncology Core
| | - Trang Nguyen
- Department of Outreach Physics, UT MD Anderson Cancer Center, Houston, TX
- Imaging and Radiation Oncology Core
| | - Sharbacha Edward
- Department of Outreach Physics, UT MD Anderson Cancer Center, Houston, TX
- Imaging and Radiation Oncology Core
| | - Shannon Hartzell
- Department of Outreach Physics, UT MD Anderson Cancer Center, Houston, TX
- Imaging and Radiation Oncology Core
| | - Mallory Glenn
- Department of Outreach Physics, UT MD Anderson Cancer Center, Houston, TX
- Imaging and Radiation Oncology Core
| | - Daniela Branco
- Department of Outreach Physics, UT MD Anderson Cancer Center, Houston, TX
- Imaging and Radiation Oncology Core
| | - Nadia Hernandez
- Department of Outreach Physics, UT MD Anderson Cancer Center, Houston, TX
- Imaging and Radiation Oncology Core
| | - Paola Alvarez
- Department of Outreach Physics, UT MD Anderson Cancer Center, Houston, TX
- Imaging and Radiation Oncology Core
| | - Andrea Molineu
- Department of Outreach Physics, UT MD Anderson Cancer Center, Houston, TX
- Imaging and Radiation Oncology Core
| | - Paige Taylor
- Department of Outreach Physics, UT MD Anderson Cancer Center, Houston, TX
- Imaging and Radiation Oncology Core
| | - Stephen Kry
- Department of Outreach Physics, UT MD Anderson Cancer Center, Houston, TX
- Imaging and Radiation Oncology Core
| |
Collapse
|
218
|
Barnes MP, Sun B, Oborn BM, Lamichhane B, Szwec S, Schmidt M, Cai B, Menk F, Greer P. Determination of the electronic portal imaging device pixel‐sensitivity‐map for quality assurance applications. Part 1: Comparison of methods. J Appl Clin Med Phys 2022; 23:e13603. [PMID: 35429102 PMCID: PMC9195035 DOI: 10.1002/acm2.13603] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 03/08/2022] [Accepted: 03/15/2022] [Indexed: 11/06/2022] Open
Abstract
Purpose Methods Results Conclusion
Collapse
Affiliation(s)
- Michael Paul Barnes
- Department of Radiation Oncology Calvary Mater Hospital Newcastle Newcastle New South Wales Australia
- School of Mathematical and Physical Sciences University of Newcastle Newcastle New South Wales Australia
| | - Baozhou Sun
- Department of Radiation Oncology Washington University in St. Louis St. Louis Missouri USA
| | - Brad Michael Oborn
- Centre for Medical Radiation Physics University of Wollongong Wollongong New South Wales Australia
- Illawarra Cancer Care Centre Wollongong Hospital Wollongong New South Wales Australia
| | - Bishnu Lamichhane
- School of Mathematical and Physical Sciences University of Newcastle Newcastle New South Wales Australia
| | - Stuart Szwec
- School of Medicine and Public Health University of Newcastle Newcastle New South Wales Australia
| | - Matthew Schmidt
- Department of Radiation Oncology Washington University in St. Louis St. Louis Missouri USA
| | - Bin Cai
- Department of Radiation Oncology Washington University in St. Louis St. Louis Missouri USA
| | - Frederick Menk
- School of Mathematical and Physical Sciences University of Newcastle Newcastle New South Wales Australia
| | - Peter Greer
- Department of Radiation Oncology Calvary Mater Hospital Newcastle Newcastle New South Wales Australia
- School of Mathematical and Physical Sciences University of Newcastle Newcastle New South Wales Australia
| |
Collapse
|
219
|
Tao S, Gong H, Michalak G, McCollough C, Leng S, Hu Y. Technical note: Evaluation of Artificial 120-kilovolt computed tomography images for radiation therapy applications. Med Phys 2022; 49:3683-3691. [PMID: 35394074 DOI: 10.1002/mp.15592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 02/25/2022] [Accepted: 02/28/2022] [Indexed: 11/09/2022] Open
Abstract
PURPOSE The purpose of this work is to evaluate the scaled CT number accuracy of an artificial 120 kV reconstruction technique based on phantom experiments in the context of radiation therapy planning. METHODS An abdomen-shaped electron density phantom was scanned on a clinical CT scanner capable of artificial 120 kV reconstruction using different tube potentials from 70 kV to 150 kV. A series of tissue equivalent phantom inserts (lung, adipose, breast, solid water, liver, inner bone, 30%/50% CaCO3, cortical bone) were placed inside the phantom. Images were reconstructed using a conventional quantitative reconstruction kernel as well as the artificial 120 kV reconstruction kernel. Scaled CT numbers of inserts were measured from images acquired at different kVs and compared with those acquired at 120 kV, which were deemed as the ground truth. The relative error was quantified as the percentage deviation of scaled CT numbers acquired at different tube potentials from their ground truth values acquired at 120 kV. RESULTS Scaled CT numbers measured from images reconstructed using the conventional reconstruction demonstrated a strong kV-dependence. The relative error in scaled CT number ranged from 0.6% (liver insert) to 31.1% (cortical bone insert). The artificial 120 kV reconstruction reduced the kV-dependence, especially for bone tissues. The relative error in scaled CT number was reduced to 0.4% (liver insert) and 2.6% (30% CaCO3 insert) using this technique. When tube potential selection was limited to the range of 90 kV to 150 kV, the relative error was further restrained to <1.2% for all tissue types. CONCLUSION Phantom results demonstrated that using the artificial 120 kV technique, it was feasible to acquire raw projection data at a desired tube potential and then reconstruct images with scaled CT numbers comparable to those obtained directly at 120 kV. In radiotherapy applications, this technique may allow optimization of tube potential without complicating clinical workflow by eliminating the necessity of maintaining multiple sets of CT calibration curves. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Shengzhen Tao
- Department of Radiology, Mayo Clinic, Jacksonville, FL, USA
| | - Hao Gong
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | | | | - Shuai Leng
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Yanle Hu
- Department of Radiation Oncology, Mayo Clinic, Phoenix, AZ, USA
| |
Collapse
|
220
|
Lehmann J, Hussein M, Barry M, Siva S, Moore A, Chu M, Díez P, Eaton DJ, Harwood J, Lonski P, Claridge Mackonis E, Meehan C, Patel R, Ray X, Shaw M, Shepherd J, Smyth G, Standen TS, Subramanian B, Greer P, Clark CH. SEAFARER – A new concept for validating radiotherapy patient specific QA for clinical trials and clinical practice. Radiother Oncol 2022; 171:121-128. [DOI: 10.1016/j.radonc.2022.04.019] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 03/22/2022] [Accepted: 04/14/2022] [Indexed: 01/12/2023]
|
221
|
Das IJ, Dogan SK, Gopalakrishnan M, Ding GX, Longo M, Franscescon P. Validity of equivalent square field concept in small field dosimetry. Med Phys 2022; 49:4043-4055. [PMID: 35344220 DOI: 10.1002/mp.15624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 03/16/2022] [Accepted: 03/16/2022] [Indexed: 11/11/2022] Open
Abstract
PURPOSE The equivalent Square (ES) concept has been used for traditional radiation fields defined by the machine collimating system. For small fields, the concept Sclin was introduced based on measuring dosimetric field width (full-width half maximum, FWHM) of the cardinal axis of the beam profiles. The pros and cons of this concept are evaluated in small fields and compared with the traditional ES using area and perimeter (4A/P) method based on geometric field size settings e.g. light field settings. METHODS One hundred thirty-seven square and rectangular fields from 5-50 mm with every possible permutation (keeping one jaw fixed and varying other jaw from 5 mm to 50 mm) were utilized to measure FWHM for the validation of Sclin . Using a microSilicon detector and a scanning water tank, measurements were performed on an Elekta (Versa) machine with Agility head and a Varian TrueBeam with different MLC/Jaw design to evaluate the Sclin concept and to understand the effect of exchange factor in small fields. Field output factors were also measured for all 137 fields. RESULTS The data fitting for fields ranging from 5-50 mm between the traditional 4A/P method and Sclin shows differences and indicates a linear relationship with distinct separation of slope for Elekta and Varian machines. As Elekta does not have y jaws, the ES based on 4A/P < Sclin but for the Varian linac 4A/P > Sclin for square fields. Our measured data shows that both methods are equally valid but does vary by the machine design. The field output factor is dependent on the elongation factor as well as machine design. For fields with sides ≥10 mm, the exchange factor is nearly identical in both machines with magnitude up to 4% which is close to measurement uncertainty (±3%) but for small fields (<10 mm) the Elekta machine has higher exchange factors compared to the Varian machine. CONCLUSION The results demonstrate that the two concepts for defining equivalent field (Sclin and 4A/P) are equivalent and can be directly related through an empirical equation. This study confirms that 4A/P is still valid for small fields except for very small fields (≤10 mm) where source occlusion is a dominating factor. The Sclin method is potentially sensitive to measurement uncertainty due to measurement of FWHM which is machine, detector and user dependent, while the 4A/P method relies mainly on geometry of the machine and has less dependency on type of machine, detector and user. The exchange factors are comparable for both types of machines. The conclusion is based on data from an Elekta with Agility head and a Varian TrueBeam machine that may have potential for bias due to light field/collimator set up and alignment. Care should be taken in extrapolating these data to any other machine. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Indra J Das
- Department of Radiation Oncology, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL, 60611, USA
| | - Serpil K Dogan
- Department of Radiation Oncology, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL, 60611, USA
| | - Mahesh Gopalakrishnan
- Department of Radiation Oncology, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL, 60611, USA
| | - George X Ding
- Department of Radiation Oncology, Vanderbilt University School of Medicine, Nashville, TN, 37232, USA
| | - Mariaconcetta Longo
- Department of Radiation Oncology Ospedale Di Vicenza, Viale Rodolfi, Vicenza, 36100, Italy
| | - Paolo Franscescon
- Department of Radiation Oncology Ospedale Di Vicenza, Viale Rodolfi, Vicenza, 36100, Italy
| |
Collapse
|
222
|
Hanada K, Fuse H, Fujisaki T, Tomita F, Yasue K. [Determination and Verification of Parameters of Lévy Distribution Incident Energy Spectrum of High-energy Electron Beam]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022; 78:473-483. [PMID: 35342124 DOI: 10.6009/jjrt.2022-1191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE The incident electron energy spectrum was determined by an estimation formula based on the Lévy distribution in order to calculate the PDD and OAR that is consistent with the measurement. METHODS EGSnrc was used to calculate PDD and OAR at nominal energies of 4, 6, 9, 12, and 15 MeV. The parameters for determining the incident electron energy spectrum were adjusted to be a reasonable value in the error between the measured and the calculated values. RESULTS Location and scaling parameters were determined to be 0.5 and 0.001, respectively. The calculated PDD based on the determination formula was in agreement with the measurement within 2 mm/2% at all depths. The OAR also was in agreement with the measurement within 2 mm/2%. CONCLUSION In this study, the incident electron energy spectrum was estimated by determining the location and scaling parameters. This method is simpler and more accurate than previously reported, and can be applied to the calculation of dose distributions in Monte Carlo simulations.
Collapse
Affiliation(s)
- Koichi Hanada
- Graduate School of Health Sciences, Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences (Current address: Department of Radiology, Chiba University Hospital).,Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences
| | - Hiraku Fuse
- Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences
| | - Tatsuya Fujisaki
- Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences
| | - Fumihiro Tomita
- Graduate School of Health Sciences, Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences
| | - Kenji Yasue
- Graduate School of Health Sciences, Ibaraki Prefectural University of Health Sciences
| |
Collapse
|
223
|
Subashi E, Dresner A, Tyagi N. Longitudinal assessment of quality assurance measurements in a 1.5 T MR-linac: Part II-Magnetic resonance imaging. J Appl Clin Med Phys 2022; 23:e13586. [PMID: 35332990 PMCID: PMC9398228 DOI: 10.1002/acm2.13586] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 02/05/2022] [Accepted: 02/25/2022] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To describe and report longitudinal quality assurance (QA) measurements for the magnetic resonance imaging (MRI) component of the Elekta Unity MR-linac during the first year of clinical use in our institution. MATERIALS AND METHODS The performance of the MRI component of Unity was evaluated with daily, weekly, monthly, and annual QA testing. The measurements monitor image uniformity, signal-to-noise ratio (SNR), resolution/detectability, slice position/thickness, linearity, central frequency, and geometric accuracy. In anticipation of routine use of quantitative imaging (qMRI), we characterize B0/B1 uniformity and the bias/reproducibility of longitudinal/transverse relaxation times (T1/T2) and apparent diffusion coefficient (ADC). Tolerance levels for QA measurements of qMRI biomarkers are derived from weekly monitoring of T1, T2, and ADC. RESULTS The 1-year assessment of QA measurements shows that daily variations in each MR quality metric are well below the threshold for failure. Routine testing procedures can reproducibly identify machine issues. The longitudinal three-dimensional (3D) geometric analysis reveals that the maximum distortion in a diameter of spherical volume (DSV) of 20, 30, 40, and 50 cm is 0.4, 0.6, 1.0, and 3.1 mm, respectively. The main source of distortion is gradient nonlinearity. Maximum peak-to-peak B0 inhomogeneity is 3.05 ppm, with gantry induced B0 inhomogeneities an order of magnitude smaller. The average deviation from the nominal B1 is within 2%, with minimal dependence on gantry angle. Mean ADC, T1, and T2 values are measured with high reproducibility. The median coefficient of variation for ADC, T1, and T2 is 1.3%, 1.1%, and 0.5%, respectively. The median bias for ADC, T1, and T2 is -0.8%, -0.1%, and 3.9%, respectively. CONCLUSION The MRI component of Unity operates within the guidelines and recommendations for scanner performance and stability. Our findings support the recently published guidance in establishing clinically acceptable tolerance levels for image quality. Highly reproducible qMRI measurements are feasible in Unity.
Collapse
Affiliation(s)
- Ergys Subashi
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Alex Dresner
- Philips Healthcare MR Oncology, Cleveland, Ohio, USA
| | - Neelam Tyagi
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| |
Collapse
|
224
|
Hegarty S, Hardcastle N, Korte J, Kron T, Everitt S, Rahim S, Hegi-Johnson F, Franich R. Please Place Your Seat in the Full Upright Position: A Technical Framework for Landing Upright Radiation Therapy in the 21 st Century. Front Oncol 2022; 12:821887. [PMID: 35311128 PMCID: PMC8929673 DOI: 10.3389/fonc.2022.821887] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Accepted: 01/27/2022] [Indexed: 12/20/2022] Open
Abstract
Delivering radiotherapy to patients in an upright position can allow for increased patient comfort, reduction in normal tissue irradiation, or reduction of machine size and complexity. This paper gives an overview of the requirements for the delivery of contemporary arc and modulated radiation therapy to upright patients. We explore i) patient positioning and immobilization, ii) simulation imaging, iii) treatment planning and iv) online setup and image guidance. Treatment chairs have been designed to reproducibly position seated patients for treatment and can be augmented by several existing immobilisation systems or promising emerging technologies such as soft robotics. There are few solutions for acquiring CT images for upright patients, however, cone beam computed tomography (CBCT) scans of upright patients can be produced using the imaging capabilities of standard Linacs combined with an additional patient rotation device. While these images will require corrections to make them appropriate for treatment planning, several methods indicate the viability of this approach. Treatment planning is largely unchanged apart from translating gantry rotation to patient rotation, allowing for a fixed beam with a patient rotating relative to it. Rotation can be provided by a turntable during treatment delivery. Imaging the patient with the same machinery as used in treatment could be advantageous for online plan adaption. While the current focus is using clinical linacs in existing facilities, developments in this area could also extend to lower-cost and mobile linacs and heavy ion therapy.
Collapse
Affiliation(s)
- Sarah Hegarty
- School of Science, RMIT University, Melbourne, VIC, Australia.,Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| | - Nicholas Hardcastle
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia.,Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia.,Sir Peter MacCallum Department of Oncology, Faculty of Medicine, Dentistry and Health Science, University of Melbourne, Parkville, VIC, Australia
| | - James Korte
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia.,Department of Biomedical Engineering, School of Engineering, University of Melbourne, Melbourne, VIC, Australia
| | - Tomas Kron
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia.,Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia.,Sir Peter MacCallum Department of Oncology, Faculty of Medicine, Dentistry and Health Science, University of Melbourne, Parkville, VIC, Australia
| | - Sarah Everitt
- Sir Peter MacCallum Department of Oncology, Faculty of Medicine, Dentistry and Health Science, University of Melbourne, Parkville, VIC, Australia.,Department of Radiation Therapy, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| | - Sulman Rahim
- Department of Radiation Therapy, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| | - Fiona Hegi-Johnson
- Sir Peter MacCallum Department of Oncology, Faculty of Medicine, Dentistry and Health Science, University of Melbourne, Parkville, VIC, Australia.,Department of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| | - Rick Franich
- School of Science, RMIT University, Melbourne, VIC, Australia.,Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| |
Collapse
|
225
|
Duchaine J, Markel D, Bouchard H. Efficient dose-rate correction of silicon diode relative dose measurements. Med Phys 2022; 49:4056-4070. [PMID: 35315526 DOI: 10.1002/mp.15628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 12/21/2021] [Accepted: 03/17/2022] [Indexed: 11/12/2022] Open
Abstract
PURPOSE Silicon diodes are often the detector of choice for relative dose measurements, particularly in the context of radiotherapy involving small photon beams. However, a major drawback lies in their dose-rate dependency. Although ionization chambers are often too large for small field output factor measurements, they are valuable instruments to provide reliable percent-depth dose curves in reference beams. The aim of this work is to propose a practical and accurate method for the characterization of silicon diode dose-rate dependence correction factors using ionization chamber measurements as a reference. METHODS The robustness of ionization chambers for percent-depth dose measurements is used to quantify the dose-rate dependency of a diode detector. A mathematical formalism, which exploits the error induced in percent-depth ionization curves for diodes by their dose-rate dependency, is developed to derive a dose-rate correction factor applicable to diode relative measurements. The method is based on the definition of the recombination correction factor given in the addendum to TG 51 and is applied to experimental measurements performed on a CyberKnife M6 radiotherapy unit using a PTW 60012 diode detector. A measurement-based validation is provided by comparing corrected percent-depth ionization curves to measurements performed with a PTW 60019 diamond detector which does not exhibit dose-rate dependence. RESULTS Results of dose-rate correction factors for percent-depth ionization curves, off-axis ratios, tissue-phantom ratios and small field output factors are coherent with the expected behavior of silicon diode detectors. For all considered setups and field sizes, the maximum correction and the maximum impact of the uncertainties induced by the correction are obtained for off-axis ratios for the 60 mm collimator, with a correction of 2.5% and an uncertainty of 0.34%. For output factors, corrections range from 0.33% to 0.82% for all field sizes considered, and increase with the reduction of the field size. Comparison of percent-depth ionization curves corrected for dose-rate and for in-depth beam quality variations illustrate excellent agreement with measurements performed using the diamond detector. CONCLUSIONS The proposed method allows the efficient and precise correction of the dose-rate dependence of silicon diode detectors in the context of clinical relative dosimetry. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Jasmine Duchaine
- Département de physique, Université de Montréal, Campus MIL, 1375 Av. Thérèse Lavoie-Roux, Montréal, QC, H2V 0B3, Canada.,Centre de recherche du Centre hospitalier de l'Université de Montréal, 900 rue Saint-Denis, Montréal, QC, H2X 0A9, Canada
| | - Daniel Markel
- Département de radio-oncologie, Centre hospitalier de l'Université de Montréal, 1051 Rue Sanguinet, Montréal, QC, H2X 3E4, Canada
| | - Hugo Bouchard
- Département de physique, Université de Montréal, Campus MIL, 1375 Av. Thérèse Lavoie-Roux, Montréal, QC, H2V 0B3, Canada.,Centre de recherche du Centre hospitalier de l'Université de Montréal, 900 rue Saint-Denis, Montréal, QC, H2X 0A9, Canada.,Département de radio-oncologie, Centre hospitalier de l'Université de Montréal, 1051 Rue Sanguinet, Montréal, QC, H2X 3E4, Canada
| |
Collapse
|
226
|
Brown TAD, Fagerstrom JM, Beck C, Holloway C, Burton K, Kaurin DGL, Mahendra S, Luckstead M, Kielar K, Kerns J. Determination of commissioning criteria for multileaf-collimator, stereotactic radiosurgery treatments on Varian TrueBeam and Edge machines using a novel anthropomorphic phantom. J Appl Clin Med Phys 2022; 23:e13581. [PMID: 35290710 PMCID: PMC9195028 DOI: 10.1002/acm2.13581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Revised: 10/22/2021] [Accepted: 02/21/2022] [Indexed: 11/11/2022] Open
Abstract
An anthropomorphic phantom has been developed by Varian Medical Systems for commissioning multileaf‐collimator (MLC), stereotactic radiosurgery (SRS) treatments on Varian TrueBeam and Edge linear accelerators. Northwest Medical Physics Center (NMPC) has collected end‐to‐end data on these machines, at six independent clinical sites, to establish baseline dosimetric and geometric commissioning criteria for SRS measurements with this phantom. The Varian phantom is designed to accommodate four interchangeable target cassettes, each designed for a specific quality assurance function. End‐to‐end measurements utilized the phantom to verify the coincidence of treatment isocenter with a hidden target in a Winston‐Lutz cassette after localization using cone‐beam computed tomography (CBCT). Dose delivery to single target (2 cm) and single‐isocenter, multitarget (2 and 1 cm) geometries was verified using ionization chamber and EBT3 film cassettes. A nominal dose of 16 Gy was prescribed for each plan using a site's standard beam geometry for SRS cases. Measurements were performed with three Millennium and three high‐definition MLC machines at beam energies of 6‐MV and 10‐MV flattening‐filter‐free energies. Each clinical site followed a standardized procedure for phantom simulation, treatment planning, quality assurance, and treatment delivery. All treatment planning and delivery was performed using ARIA oncology information system and Eclipse treatment planning software. The isocenter measurements and irradiated film were analyzed using DoseLab quality assurance software; gamma criteria of 3%/1 mm, 3%/0.5 mm, and 2%/1 mm were applied for film analysis. Based on the data acquired in this work, the recommended commissioning criteria for end‐to‐end SRS measurements with the Varian phantom are as follows: coincidence of treatment isocenter and CBCT‐aligned hidden target < 1 mm, agreement of measured chamber dose with calculated dose ≤ 5%, and film gamma passing > 90% for gamma criteria of 3%/1 mm after DoseLab auto‐registration shifts ≤ 1 mm in any direction.
Collapse
Affiliation(s)
| | | | - Caleb Beck
- Northwest Medical Physics Center, Lynnwood, Washington, USA
| | | | - Krista Burton
- Northwest Medical Physics Center, Lynnwood, Washington, USA
| | | | | | | | - Kayla Kielar
- Varian Medical Systems, Palo Alto, California, USA
| | - James Kerns
- Varian Medical Systems, Palo Alto, California, USA
| |
Collapse
|
227
|
Taylor PA, Lowenstein J, Followill D, Kry SF. The Value of On-Site Proton Audits. Int J Radiat Oncol Biol Phys 2022; 112:1004-1011. [PMID: 34780973 PMCID: PMC8863623 DOI: 10.1016/j.ijrobp.2021.10.145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Revised: 10/06/2021] [Accepted: 10/22/2021] [Indexed: 10/19/2022]
Abstract
PURPOSE This study aimed to highlight the value and key findings of on-site proton audits. METHODS AND MATERIALS The authors performed 38 on-site measurement-based peer reviews of proton centers participating in National Cancer Institute-funded clinical trials. The reviews covered beam calibration, lateral and depth measurements, mechanical checks, treatment planning and clinical practice, and quality assurance (QA) practices. Program deficiencies were noted, and recommendations were made about ways institutions could improve their practices. RESULTS Institutions received an average of 3 (range, 1-8) recommendations for practice improvements. The number of deficiencies did not decrease over time, highlighting the continued need for this type of peer review. The most common deficiencies were for Task Group-recommended QA compliance (97% of centers), computed tomography number (CTN) to relative linear stopping power conversion (59%), and QA procedures (53%). In addition, 32% of institutions assessed failed at least 1 lateral beam profile measurement (<90% of pixels passing 3% [global]/3 mm; 10% threshold), despite passing internal QA measurements. These failures occurred for several different plan configurations (large, small, shallow, and deep targets) and at different depths in the beam path (proximal to target, central, and distal). CTN to relative linear stopping power conversion curves showed deviations at low, mid, and high CTNs and highlighted areas of inconsistency between proton centers, with many centers falling outside of 2 sigma of the mean curve of their peers. All deficiencies from the peer review were discussed with the institutions, and many implemented dosimetric treatment planning and practice changes to improve the accuracy of their system and consistency with other institutions. CONCLUSIONS This peer review program has been integral in confirming and promoting consistency and best practice across proton centers for clinical trials, minimizing deviations for outcomes data.
Collapse
Affiliation(s)
- Paige A Taylor
- The University of Texas, MD Anderson Cancer Center, Houston, Texas.
| | | | - David Followill
- The University of Texas, MD Anderson Cancer Center, Houston, Texas
| | - Stephen F Kry
- The University of Texas, MD Anderson Cancer Center, Houston, Texas
| |
Collapse
|
228
|
Affiliation(s)
- Ichiro Yamaguchi
- Department of Environmental Health, National Institute of Public Health, 351-0197, Wako, Japan
| | - Shuichi Ozawa
- Hiroshima High-Precision Radiotherapy Cancer Center, 732-0057, Hiroshima, Japan; Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, 734-8551, Hiroshima, Japan.
| |
Collapse
|
229
|
Kron T, Fox C, Ebert MA, Thwaites D. Quality management in radiotherapy treatment delivery. J Med Imaging Radiat Oncol 2022; 66:279-290. [PMID: 35243785 DOI: 10.1111/1754-9485.13348] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Accepted: 10/29/2021] [Indexed: 12/17/2022]
Abstract
Radiation Oncology continues to rely on accurate delivery of radiation, in particular where patients can benefit from more modulated and hypofractioned treatments that can deliver higher dose to the target while optimising dose to normal structures. These deliveries are more complex, and the treatment units are more computerised, leading to a re-evaluation of quality assurance (QA) to test a larger range of options with more stringent criteria without becoming too time and resource consuming. This review explores how modern approaches of risk management and automation can be used to develop and maintain an effective and efficient QA programme. It considers various tools to control and guide radiation delivery including image guidance and motion management. Links with typical maintenance and repair activities are discussed, as well as patient-specific quality control activities. It is demonstrated that a quality management programme applied to treatment delivery can have an impact on individual patients but also on the quality of treatment techniques and future planning. Developing and customising a QA programme for treatment delivery is an important part of radiotherapy. Using modern multidisciplinary approaches can make this also a useful tool for department management.
Collapse
Affiliation(s)
- Tomas Kron
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.,Sir Peter MacCallum Institute of Oncology, Melbourne University, Melbourne, Victoria, Australia.,Centre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales, Australia
| | - Chris Fox
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia
| | - Martin A Ebert
- Centre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales, Australia.,Department of Radiation Oncology, Sir Charles Gairdner Hospital, Perth, Western Australia, Australia.,School of Physics, Mathematics and Computing, University of Western Australia, Perth, Western Australia, Australia.,5D Clinics, Perth, Western Australia, Australia
| | - David Thwaites
- Institute of Medical Physics, School of Physics, University of Sydney, Sydney, New South Wales, Australia.,Medical Physics Group, Leeds Institute of Cardiovascular and Metabolic Medicine and Leeds Institute of Medical Research, University of Leeds, Leeds, UK
| |
Collapse
|
230
|
A novel end-to-end test for combined dosimetric and geometric treatment verification using a 3D-printed phantom. Med Dosim 2022; 47:177-183. [DOI: 10.1016/j.meddos.2022.02.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 12/20/2021] [Accepted: 02/04/2022] [Indexed: 11/22/2022]
|
231
|
Jursinic P, Jordan K, Chen C. Positions of radiation isocenter and the couch rotation center established by Winston-Lutz and optical measurements. Tech Innov Patient Support Radiat Oncol 2022; 21:46-50. [PMID: 35243044 PMCID: PMC8861408 DOI: 10.1016/j.tipsro.2022.01.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Revised: 01/30/2022] [Accepted: 01/31/2022] [Indexed: 12/31/2022] Open
Abstract
Purpose To compare x-ray and optical imaging methods for measuring the relative position of radiation isocenter and couch rotation center. To show the impact of radiation isocenter size and target motion on the margins for target contours. Methods Winston-Lutz measurements are made using EPID images. Image analysis was done with public domain software, ImageJ, and spreadsheets written in Microsoft Excel. A comparison between the center of a high density test object and center of the MLC collimated beam is used to judge the relative position of the radiation isocenter in space for gantry and couch rotation. Additionally, motion of the target with couch rotation is determined with an optical imaging system. Five different accelerators, two TrueBeams, a Trilogy, and two VersaHDs, were assessed by Winston-Lutz and optical methods. Results The shift in the radiation isocenter with gantry rotation is found to be a tri-axial ellipsoid. Shifts in the target position with respect to radiation isocenter with couch rotation were between 0.4 and 0.6 mm. The Winston-Lutz and optical method determination of couch rotation center agreed within measurement uncertainty. Conclusions Image analysis yields precise data on linear accelerator radiation isocenter and rotation centers of the couch. The Winston-Lutz and optical methods agreed within measurement uncertainty.
Collapse
Affiliation(s)
- Paul Jursinic
- West Michigan Cancer Center, 200 North Park St., Kalamazoo, MI 49007, USA
- Corresponding author.
| | - Karl Jordan
- St. Vincent’s Private Hospital, Merrion Road, Dublin 4 D04 N2E0, Ireland
| | - Chen Chen
- West Michigan Cancer Center, 200 North Park St., Kalamazoo, MI 49007, USA
| |
Collapse
|
232
|
Synchronous bilateral breast carcinoma irradiation: A comparative investigation between flattened and unflattened beams. Appl Radiat Isot 2022; 181:110079. [DOI: 10.1016/j.apradiso.2021.110079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 12/18/2021] [Accepted: 12/21/2021] [Indexed: 12/24/2022]
|
233
|
Das IJ, Dawes SL, Dominello MM, Kavanagh B, Miyamoto CT, Pawlicki T, Santanam L, Vinogradskiy Y, Yeung AR. Quality and Safety Considerations in Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy: An ASTRO Safety White Paper Update. Pract Radiat Oncol 2022; 12:e253-e268. [DOI: 10.1016/j.prro.2022.03.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 03/01/2022] [Indexed: 11/17/2022]
|
234
|
Al-Hallaq HA, Cerviño L, Gutierrez AN, Havnen-Smith A, Higgins SA, Kügele M, Padilla L, Pawlicki T, Remmes N, Smith K, Tang X, Tomé WA. AAPM task group report 302: Surface guided radiotherapy. Med Phys 2022; 49:e82-e112. [PMID: 35179229 PMCID: PMC9314008 DOI: 10.1002/mp.15532] [Citation(s) in RCA: 78] [Impact Index Per Article: 39.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2021] [Revised: 12/26/2021] [Accepted: 02/05/2022] [Indexed: 11/06/2022] Open
Abstract
The clinical use of surface imaging has increased dramatically with demonstrated utility for initial patient positioning, real-time motion monitoring, and beam gating in a variety of anatomical sites. The Therapy Physics Subcommittee and the Imaging for Treatment Verification Working Group of the American Association of Physicists in Medicine commissioned Task Group 302 to review the current clinical uses of surface imaging and emerging clinical applications. The specific charge of this task group was to provide technical guidelines for clinical indications of use for general positioning, breast deep-inspiration breath-hold (DIBH) treatment, and frameless stereotactic radiosurgery (SRS). Additionally, the task group was charged with providing commissioning and on-going quality assurance (QA) requirements for surface guided radiation therapy (SGRT) as part of a comprehensive QA program including risk assessment. Workflow considerations for other anatomic sites and for computed tomography (CT) simulation, including motion management are also discussed. Finally, developing clinical applications such as stereotactic body radiotherapy (SBRT) or proton radiotherapy are presented. The recommendations made in this report, which are summarized at the end of the report, are applicable to all video-based SGRT systems available at the time of writing. Review current use of non-ionizing surface imaging functionality and commercially available systems. Summarize commissioning and on-going quality assurance (QA) requirements of surface image-guided systems, including implementation of risk or hazard assessment of surface guided radiotherapy as a part of a total quality management program (e.g., TG-100). Provide clinically relevant technical guidelines that include recommendations for the use of SGRT for general patient positioning, breast DIBH, and frameless brain SRS, including potential pitfalls to avoid when implementing this technology. Discuss emerging clinical applications of SGRT and associated QA implications based on evaluation of technology and risk assessment. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Hania A Al-Hallaq
- Department of Radiation & Cellular Oncology, University of Chicago, Chicago, IL, 60637, USA
| | - Laura Cerviño
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Alonso N Gutierrez
- Department of Radiation Oncology, Miami Cancer Institute, Miami, FL, 33173, USA
| | | | - Susan A Higgins
- Department of Therapeutic Radiology, Yale University, New Haven, CT, 06520, USA
| | - Malin Kügele
- Department of Hematology, Oncology and Radiation Physics, Skåne University, Lund, 221 00, Sweden.,Medical Radiation Physics, Department of Clinical Sciences, Lund University, Lund, 221 00, Sweden
| | - Laura Padilla
- Department of Radiation Medicine & Applied Sciences, University of California, San Diego, La Jolla, CA, 92093, USA
| | - Todd Pawlicki
- Department of Radiation Medicine & Applied Sciences, University of California, San Diego, La Jolla, CA, 92093, USA
| | - Nicholas Remmes
- Department of Radiation Oncology, Mayo Clinic, Rochester, MN, 55905, USA
| | - Koren Smith
- IROC Rhode Island, University of Massachusetts Chan Medical School, Lincoln, RI, 02865, USA
| | | | - Wolfgang A Tomé
- Department of Radiation Oncology and Department of Neurology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, NY, 10461, USA
| |
Collapse
|
235
|
Ma M, Liu C, Wei R, Liang B, Dai J. Predicting machine's performance record using the stacked long short-term memory (LSTM) neural networks. J Appl Clin Med Phys 2022; 23:e13558. [PMID: 35170838 PMCID: PMC8906230 DOI: 10.1002/acm2.13558] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2021] [Revised: 11/23/2021] [Accepted: 01/21/2022] [Indexed: 01/02/2023] Open
Abstract
Purpose The record of daily quality control (QC) items shows machine performance patterns and potentially provides warning messages for preventive actions. This study developed a neural network model that could predict the record and trend of data variations quantitively. Methods and materials The record of 24 QC items for a radiotherapy machine was investigated in our institute. The QC records were collected daily for 3 years. The stacked long short‐term memory (LSTM) model was used to develop the neural network model. A total of 867 records were collected to predict the record for the next 5 days. To compare the stacked LSTM, the autoregressive integrated moving average model (ARIMA) was developed on the same data set. The accuracy of the model was quantified by the mean absolute error (MAE), root‐mean‐square error (RMSE), and coefficient of determination (R2). To validate the robustness of the model, the record of four QC items was collected for another radiotherapy machine, which was input into the stacked LSTM model without changing any hyperparameters and ARIMA model. Results The mean MAE, RMSE, andR2 with 24 QC items were 0.013, 0.020, and 0.853 in LSTM, while 0.021, 0.030, and 0.618 in ARIMA, respectively. The results showed that the stacked LSTM outperforms the ARIMA. Moreover, the mean MAE, RMSE, andR2 with four QC items were 0.102, 0.151, and 0.770 in LSTM, while 0.162, 0.375, and 0.550 in ARIMA, respectively. Conclusions In this study, the stacked LSTM model can accurately predict the record and trend of QC items. Moreover, the stacked LSTM model is robust when applied to another radiotherapy machine. Predicting future performance record will foresee possible machine failure, allowing early machine maintenance and reducing unscheduled machine downtime.
Collapse
Affiliation(s)
- Min Ma
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Chenbin Liu
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital and Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China
| | - Ran Wei
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Bin Liang
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jianrong Dai
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
236
|
Duggar WN, Morris B, He R, Yang C. Total workflow uncertainty of frameless radiosurgery with the Gamma Knife Icon cone-beam computed tomography. J Appl Clin Med Phys 2022; 23:e13564. [PMID: 35157361 PMCID: PMC9121051 DOI: 10.1002/acm2.13564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 12/29/2021] [Accepted: 02/01/2022] [Indexed: 11/21/2022] Open
Abstract
Objective Frameless treatment with the Gamma Knife Icon is still relatively new as a treatment option. As a result, additional confidence/knowledge about the uncertainty that exists within each portion of the treatment workflow could be gained especially regarding steps that have not been previously studied in the literature. Methods The Icon base delivery device (Perfexion) uncertainty is quantified and validated. The novel portions of the Icon such as mask immobilization, cone‐beam computed tomography image guidance, and the intrafraction motion management methods are studied specifically and to a greater extent to determine a total workflow uncertainty of frameless treatment with the Icon. Results The uncertainty of each treatment workflow step has been identified with the total workflow uncertainty being identified in this work as 1.3 mm with a standard deviation of 0.51 mm. Conclusion The total uncertainty of frameless treatment with the Icon has been evaluated and this data may indicate the need for setup margin in this setting with data that could be used by other institutions to calculate needed setup margin per their preferred recipe after validation of this data in their context.
Collapse
Affiliation(s)
- William N Duggar
- Department of Radiation Oncology, University of MS Medical Center, Jackson, Mississippi, USA
| | - Bart Morris
- Department of Radiation Oncology, University of MS Medical Center, Jackson, Mississippi, USA
| | - Rui He
- Department of Radiation Oncology, University of MS Medical Center, Jackson, Mississippi, USA
| | - Claus Yang
- Department of Radiation Oncology, University of MS Medical Center, Jackson, Mississippi, USA
| |
Collapse
|
237
|
Li Y, Liu H, Huang N, Wang Z, Zhang C. The Measurement of the Surface Dose in Regular and Small Radiation Therapy Fields Using Cherenkov Imaging. Technol Cancer Res Treat 2022; 21:15330338211073432. [PMID: 35119327 PMCID: PMC8819764 DOI: 10.1177/15330338211073432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Purpose: The aim of this study is to measure the output factor (OF)
and profile of surface dose in regular and small radiation therapy fields using
Cherenkov imaging (CI). Methods: A medical linear accelerator
(linac) was employed to generate radiation fields, including regular open photon
field (ROPF), regular wedge photon field (RWPF), regular electron field (REF)
and small photon field (SPF). The photon beams consisted of two filter modes
including flattening filter (FF) and flattening filter free (FFF). All fields
were delivered to a solid water phantom. Cherenkov light was captured using a
charge-coupled device system during phantom irradiation. The OF and profile of
surface dose measured by CI were compared with those determined by film
measurement, ionization chamber measurement and treatment planning system
calculation in order to examine the feasibility of measuring surface dose OF and
profile using CI. Results: The discrepancy between surface dose OF
measured by CI and that determined by other methods is less than 6% in ROPFs
with size less than 10 × 10 cm2, REFs with size less than 10 × 10
cm2, and SPFs except for 1 × 1 cm2 field. In the flat
profile region, the discrepancy between surface dose profile measured by CI and
that determined by other methods is less than 4% in REFs and less than 3% in
ROPFs, RWPFs, and SPFs except for 1 × 1 cm2 field. The discrepancy of the
surface dose profile is in compliance with the recommendation by IAEA TRS 430
reports. The discrepancy between field width measured by CI and that determined
by film measurement is equal to or less than 2 mm, which is within the tolerance
recommend by the guidelines of linac quality assurance in regular open FF photon
fields, SPFs, and REFs with cone size of 10 × 10 cm2 in area.
Conclusion: CI can be used to quantitatively measure the OF and
profile of surface dose. It is feasible to use CI to measure the surface dose
profile and field width in regular open FF photon fields and SPFs except for
1 × 1 cm2 field.
Collapse
Affiliation(s)
- Yi Li
- State Key Laboratory of Transient Optics and Photonics, Xi’an
Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an
710119, China
- School of Physics, Xi’an Jiaotong University, Xi’an 710049, China
- University of Chinese Academy of Sciences, Beijing 100049,
China
| | - HongJun Liu
- State Key Laboratory of Transient Optics and Photonics, Xi’an
Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an
710119, China
- Collaborative Innovation Center of Extreme Optics, Shanxi
University, Taiyuan 030006, China
- Hongjun Liu, PhD, State Key Laboratory of
Transient Optics and Photonics, Xi’an Institute of Optics and Precision
Mechanics, Chinese Academy of Sciences, Xi’an 710119, China.
Chunmin Zhang, PhD, School of Physics,
Xi’an Jiaotong University, Xi’an 710049, China.
| | - Nan Huang
- State Key Laboratory of Transient Optics and Photonics, Xi’an
Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an
710119, China
| | - Zhaolu Wang
- State Key Laboratory of Transient Optics and Photonics, Xi’an
Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an
710119, China
| | - Chunmin Zhang
- School of Physics, Xi’an Jiaotong University, Xi’an 710049, China
- Hongjun Liu, PhD, State Key Laboratory of
Transient Optics and Photonics, Xi’an Institute of Optics and Precision
Mechanics, Chinese Academy of Sciences, Xi’an 710119, China.
Chunmin Zhang, PhD, School of Physics,
Xi’an Jiaotong University, Xi’an 710049, China.
| |
Collapse
|
238
|
Moncion A, Wilson M, Ma R, Marsh R, Burmeister J, Dryden D, Lack D, Grubb M, Mayville A, Jursinic P, Dess K, Kamp J, Young K, Dilworth JT, Kestin L, Jagsi R, Mietzel M, Vicini F, Pierce LJ, Moran JM. Evaluation of Dose Accuracy in the Near-Surface Region for Whole Breast Irradiation Techniques in a Multi-Institutional Consortium. Pract Radiat Oncol 2022; 12:e317-e328. [DOI: 10.1016/j.prro.2022.01.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 11/02/2021] [Accepted: 01/10/2022] [Indexed: 11/29/2022]
|
239
|
Foy JJ, Dogan SK, Yadav P, Mittal BB, Das IJ. Transferability of patients for radiation treatment between unmatched machines. J Appl Clin Med Phys 2022; 23:e13544. [PMID: 35098654 PMCID: PMC8992942 DOI: 10.1002/acm2.13544] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 11/07/2021] [Accepted: 01/14/2022] [Indexed: 11/24/2022] Open
Abstract
Purpose The feasibility of transferring patients between unmatched machines for a limited number of treatment fractions was investigated for three‐dimensional conformal radiation therapy (3DCRT) and volumetric modulated arc therapy (VMAT) treatments. Methods Eighty patient‐plans were evaluated on two unmatched linacs: Elekta Versa HD and Elekta Infinity. Plans were equally divided into pelvis 3DCRT, prostate VMAT, brain VMAT, and lung VMAT plans. While maintaining the number of monitor units (MUs), plans were recalculated on the machine not originally used for treatment. Relative differences in dose were calculated between machines for the target volume and organs at risk (OARs). Differences in mean dose were assessed with paired t‐tests (p < 0.05). The number of interchangeable fractions allowable before surpassing a cumulative ±5% difference in dose was determined. Additionally, patient‐specific quality assurance (PSQA) measurements using ArcCHECK for both machines were compared with distributions calculated on the machine originally used for treatment using gradient compensation (GC) with 2%/2‐mm criteria. Results Interchanging the two machines for pelvic 3DCRT and VMAT (prostate, brain, and lung) plans resulted in an average change in target mean dose of 0.9%, −0.5%, 0.6%, 0.5%, respectively. Based on the differences in dose to the prescription point when changing machines, statistically, nearly one‐fourth of the prescribed fractions could be transferred between linacs for 3DCRT plans. While all of the prescribed fractions could typically be transferred among prostate VMAT plans, a rather large number of treatment fractions, 31% and 38%, could be transferred among brain and lung VMAT plans, respectively, without exceeding a ±5% change in the prescribed dose for two Elekta machines. Additionally, the OAR dosage was not affected within the given criterion with change of machine. Conclusions Despite small differences in calculated dose, transferring patients between two unmatched Elekta machines with similar multileaf collimator (MLC)‐head for target coverage and minimum changes in OAR dose is possible for a limited number of fractions (≤3) to improve clinical flexibility and institutional throughput along with patient satisfaction. A similar study could be carried out for other machines for operational throughput.
Collapse
Affiliation(s)
- Joseph J. Foy
- Department of Radiation Oncology Northwestern Memorial Hospital Northwestern University Feinberg School of Medicine Chicago Illinois USA
| | - Serpil K. Dogan
- Department of Radiation Oncology Northwestern Memorial Hospital Northwestern University Feinberg School of Medicine Chicago Illinois USA
| | - Poonam Yadav
- Department of Radiation Oncology Northwestern Memorial Hospital Northwestern University Feinberg School of Medicine Chicago Illinois USA
| | - Bharat B. Mittal
- Department of Radiation Oncology Northwestern Memorial Hospital Northwestern University Feinberg School of Medicine Chicago Illinois USA
| | - Indra J. Das
- Department of Radiation Oncology Northwestern Memorial Hospital Northwestern University Feinberg School of Medicine Chicago Illinois USA
| |
Collapse
|
240
|
Savanović M, Allali S, Jaroš D, Foulquier JN. Does irregular breathing impact on respiratory gated radiation therapy of lung stereotactic body radiation therapy treatments? Med Dosim 2022; 47:151-157. [PMID: 35093268 DOI: 10.1016/j.meddos.2022.01.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 12/02/2021] [Accepted: 01/06/2022] [Indexed: 11/29/2022]
Abstract
The impact of irregular breathing on respiratory gated radiation therapy (RGRT) was evaluated for lung stereotactic body radiation therapy (SBRT) treatments. Measurements in the static mode were performed with different field sizes, depths of the measurements, breathing periods and duty cycles, using the Farmer ion chamber, PinPoint ion chamber, and microDiamond detector. The output constancy (OC) was evaluated between gated and nongated beams. Measurements in the dynamic mode for regular and irregular breathing in phase- and amplitude-gated modes, were performed with the amplitude of target motion from 5 mm to 25 mm, and breathing period from 3 to 6 s, for ion chamber, and film inserts. The dose discrepancy was evaluated for the ion chamber insert. The gamma passing rate was evaluated with film dosimetry. In the static mode, the maximum obtained OC was 0.8% using the Farmer ion chamber, 1% (p < 0.001) using the microDiamond detector, and 1.4% (p < 0.001) using the PinPoint ion chamber. In the dynamic mode, good agreement between planned and measured doses was obtained for regular breathing, 2.08 ± 0.48% (1.57 to 2.74%), which increased to 3.42 ± 1.24% (1.58 to 6.69%) for irregular breathing. The gamma passing rate of 3mm/3%, 3mm/2%, 3mm/1% and 2mm/2% was 99.4% ± 0.3, 98.2 ± 0.8%, 88.2 ± 3.0% and 96.4 ± 1.0% for regular and 97.2% ± 1.6%, 95.1 ± 2.6%, 85.6 ± 3.0% and 92.9 ± 2.9% for irregular breathing patterns (p < 0.01), respectively. For a slightly irregular breathing amplitude, lung SBRT cancer patients can be treated in the phase-gated mode.
Collapse
Affiliation(s)
- Milovan Savanović
- Faculty of Medicine, University of Paris-Saclay, Le Kremlin-Bicêtre, 94276, France; Department of Radiation Oncology, Tenon Hospital, APHP, Sorbonne University, Paris, 75020, France.
| | - Sophiane Allali
- Faculty of Medicine, University of Paris, Paris, 75006, France
| | - Dražan Jaroš
- Affidea, International Medical Centers, Center for Radiotherapy, Banja Luka, 78000, Bosnia and Herzegovina; Faculty of Medicine, University of Banja Luka, Banja Luka, 78000, Bosnia and Herzegovina
| | - Jean-Noël Foulquier
- Department of Radiation Oncology, Tenon Hospital, APHP, Sorbonne University, Paris, 75020, France
| |
Collapse
|
241
|
Jin XL, Song JB, Peng JX, Pan XP, Guo R, Xing XF. Study on the established customized limits for the daily quality assurance procedure. JOURNAL OF RADIATION RESEARCH 2022; 63:128-136. [PMID: 34734293 PMCID: PMC8776697 DOI: 10.1093/jrr/rrab079] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 05/25/2021] [Accepted: 07/21/2021] [Indexed: 06/02/2023]
Abstract
Since there are no corresponding specification limits for some new daily quality assurance (QA) items in the TG-142, it is a compromise that the specification limits used in the monthly or annual QA procedures are used for the daily QA procedure in work. But there is no basis for whether this is feasible. The purpose of this article is to analyze QA results using SPC to determine the tolerance limits at our institution, and to present the usefulness of the analysis method using SPC. The data of three groups daily QA processes performed with Daily QA3 in three years were analyzed using statistical process control (SPC). For calculating capability indices (Cp, Cpk, Cpm and Cpmk) of processes, the appropriate number of calculation points was analyzed firstly. Then, in calculating the capability indices for output, limits ±3% of the daily QA in the TG-142 were used as the specification limit, while for flatness and symmetry, an annual QA limits of ±1% was used. For putting forward measures to solve the problem, customized tolerance and action limits were established for each process. And the process control charts calculated using data measured by the five therapists and a medical physicist were compared. At least six to eight weeks of control daily check data points (i.e. 30-40 points) should be used for calculating the individuals and moving range (I-MR) control chart to ensure the stability of control lines. Process capability indices of output were all ≥1, some were up to 3-4. While for symmetry, some processes failed to meet the requirements that capability indices were < 1. For different processes of the same daily QA items, the calculated customized limits were quite different. The range of upper control line (UCL) and lower control line (LCL) was smaller for output and the CL was closer to the target value of 0 for flatness and symmetry in the I-MR control chart calculated using data measured by one staff. For different quality control processes without management by the SPC method at our institution, calculated tolerance and action limits of the same measurement item were quite different. And in most measurement items, the specification limits used in the monthly or annual QA procedures in the TG-142 are not suitable to the daily QA procedure. So the analysis method using SPC is useful and necessary.
Collapse
Affiliation(s)
| | | | | | | | | | - Xiao-Fen Xing
- Corresponding author. Center of Radiation Oncology, Shanxi Cancer Hospital, No. 3, Zhigong Xincun, Taiyuan, Shanxi 030032, China. Tel: (86)03514881611; Fax: (86)03514881611;
| |
Collapse
|
242
|
Velten C, Goddard L, Jeong K, Garg MK, Tomé WA. Clinical Assessment of a Novel Ring Gantry Linear Accelerator-Mounted Helical Fan-Beam kVCT System. Adv Radiat Oncol 2022; 7:100862. [PMID: 35036634 PMCID: PMC8749200 DOI: 10.1016/j.adro.2021.100862] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 11/23/2021] [Indexed: 12/22/2022] Open
Abstract
Purpose To assess clinically relevant image quality metrics (IQMs) of helical fan beam kilovoltage (kV) fan beam computed tomography (CT). Methods and Materials kVCT IQMs were evaluated on an Accuray Radixact unit equipped with helical fan beam kVCT to assess the capabilities of this newly available modality. kVCT IQMs were evaluated and compared to a kVCT simulator and linear accelerator-based cone beam CTs (CBCT) using a commercial CBCT image quality phantom. kVCTs were acquired on the Accuray Radixact for all combinations of kVp and mAs in fine mode using a 440-mm field of view (FOV). Evaluated IQMs were spatial resolution, overall uniformity, subject contrast, contrast-to-noise ratio (CNR), and effective slice thickness. Imaging dose was assessed for planar kV imaging. Results On this kVCT system spatial resolution and contrast were consistent across all settings with 0.28 ± 0.03 lp/mm and 9.8% ± 0.7% (both 95% confidence interval). CNR strongly depended on selected mode (views per rotation) and body size (mA per view) and ranged between 7.9 and 34.9. Overall uniformity was greater than 97% for all settings. Large FOV was not found to substantially affect the IQMs whereas small FOV affected IQMs due to its effect on pitch. Technique-matched CT simulator scans were comparable for uniformity and contrast, while spatial resolution was higher (0.43 ± 0.06 lp/mm), and CNR was between 4% (140 kVp) and 51% (100 kVp) lower. For kV-CBCT, spatial resolutions ranging from 0.37 to 0.44 lp/mm were achieved with comparable contrast, CNR, and uniformity to kVCT. All kVCT scans exhibit imaging artifacts due to helical acquisition. Clinical acquisitions of megavoltage (MV) CT, kV-CBCT, and kVCT on the same patient showed improved and comparable image quality of kVCT compared to MVCT and kV-CBCT, respectively. Conclusions Helical fan beam kVCT allows for daily image guidance for localization and setup verification with comparable performance to existing kV-CBCT systems. Scan parameters must be selected carefully to maximize image quality for the desired tasks. Due to the large effective slice thicknesses for all parameter combinations, kVCT scans should not be used for simulation or planning of stereotactic procedures. Finally, improved image quality over MVCT has the potential to greatly improve manual and automated adaptive monitoring and planning.
Collapse
Affiliation(s)
- Christian Velten
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, New York.,Institute for Onco-Physics, Albert Einstein College of Medicine, Bronx, New York
| | - Lee Goddard
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, New York.,Institute for Onco-Physics, Albert Einstein College of Medicine, Bronx, New York
| | - Kyoungkeun Jeong
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, New York.,Institute for Onco-Physics, Albert Einstein College of Medicine, Bronx, New York
| | - Madhur K Garg
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, New York.,Institute for Onco-Physics, Albert Einstein College of Medicine, Bronx, New York
| | - Wolfgang A Tomé
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, New York.,Institute for Onco-Physics, Albert Einstein College of Medicine, Bronx, New York
| |
Collapse
|
243
|
Rippke C, Schrenk O, Renkamp CK, Buchele C, Hörner-Rieber J, Debus J, Alber M, Klüter S. Quality assurance for on-table adaptive magnetic resonance guided radiation therapy: A software tool to complement secondary dose calculation and failure modes discovered in clinical routine. J Appl Clin Med Phys 2022; 23:e13523. [PMID: 35019212 PMCID: PMC8906229 DOI: 10.1002/acm2.13523] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 11/14/2021] [Accepted: 12/19/2021] [Indexed: 11/16/2022] Open
Abstract
Online adaption of treatment plans on a magnetic resonance (MR)‐Linac enables the daily creation of new (adapted) treatment plans using current anatomical information of the patient as seen on MR images. Plan quality assurance (QA) relies on a secondary dose calculation (SDC) that is required because a pretreatment measurement is impossible during the adaptive workflow. However, failure mode and effect analysis of the adaptive planning process shows a large number of error sources, and not all of them are covered by SDC. As the complex multidisciplinary adaption process takes place under time pressure, additional software solutions for pretreatment per‐fraction QA need to be used. It is essential to double‐check SDC input to ensure a safe treatment delivery. Here, we present an automated treatment plan check tool for adaptive radiotherapy (APART) at a 0.35 T MR‐Linac. It is designed to complement the manufacturer‐provided adaptive QA tool comprising SDC. Checks performed by APART include contour analysis, electron density map examinations, and fluence modulation complexity controls. For nine of 362 adapted fractions (2.5%), irregularities regarding missing slices in target volumes and organs at risks as well as in margin expansion of target volumes have been found. This demonstrates that mistakes occur and can be detected by additional QA measures, especially contour analysis. Therefore, it is recommended to implement further QA tools additional to what the manufacturer provides to facilitate an informed decision about the quality of the treatment plan.
Collapse
Affiliation(s)
- Carolin Rippke
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Baden-Wurttemberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Baden-Wurttemberg, Germany.,Medical Faculty, University of Heidelberg, Heidelberg, Baden-Wurttemberg, Germany
| | - Oliver Schrenk
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Baden-Wurttemberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Baden-Wurttemberg, Germany.,PTW-Freiburg, Freiburg, Baden-Wurttemberg, Germany
| | - C Katharina Renkamp
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Baden-Wurttemberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Baden-Wurttemberg, Germany
| | - Carolin Buchele
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Baden-Wurttemberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Baden-Wurttemberg, Germany
| | - Juliane Hörner-Rieber
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Baden-Wurttemberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Baden-Wurttemberg, Germany.,Medical Faculty, University of Heidelberg, Heidelberg, Baden-Wurttemberg, Germany.,National Center for Tumor Diseases (NCT), Heidelberg, Baden-Wurttemberg, Germany.,German Cancer Consortium (DKTK), Core-center Heidelberg, Heidelberg, Baden-Wurttemberg, Germany.,Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Baden-Wurttemberg, Germany
| | - Jürgen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Baden-Wurttemberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Baden-Wurttemberg, Germany.,Medical Faculty, University of Heidelberg, Heidelberg, Baden-Wurttemberg, Germany.,National Center for Tumor Diseases (NCT), Heidelberg, Baden-Wurttemberg, Germany.,Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg, Baden-Wurttemberg, Germany.,German Cancer Consortium (DKTK), Core-center Heidelberg, Heidelberg, Baden-Wurttemberg, Germany.,Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Baden-Wurttemberg, Germany
| | - Markus Alber
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Baden-Wurttemberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Baden-Wurttemberg, Germany.,Medical Faculty, University of Heidelberg, Heidelberg, Baden-Wurttemberg, Germany
| | - Sebastian Klüter
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Baden-Wurttemberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Baden-Wurttemberg, Germany
| |
Collapse
|
244
|
Lee H, Park JM, Kim KH, Lee DH, Sohn MJ. Accuracy evaluation of surface registration algorithm using normal distribution transform in stereotactic body radiotherapy/radiosurgery: A phantom study. J Appl Clin Med Phys 2022; 23:e13521. [PMID: 34985179 PMCID: PMC8906233 DOI: 10.1002/acm2.13521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 12/06/2021] [Accepted: 12/18/2021] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To evaluate a feasibility of normal distribution transform (NDT) algorithm compared with the iterative closest point (ICP) method as a useful surface registration in stereotactic body radiotherapy (SBRT)/stereotactic radiosurgery (SRS). METHODS Point cloud images using the 3D triangulation technology were obtained from a depth camera-based optical imaging (OSI) system equipped in a radiosurgery room. Two surface registration algorithms, NDT and ICP, were used to measure and compare the discrepancy values between the reference and the current surfaces during the positioning of the patient. The performance evaluation was investigated by calculating the registration error and root-mean-square (RMS) values for the surface model, reposition, and target accuracy, which were analyzed statistically using a paired t-test. RESULTS For surface model accuracy, the average of the registration error and RMS values were measured as 3.56 ± 2.20 mm and 6.98 ± 1.89 mm for ICP method, and 1.76 ± 1.32 mm and 3.58 ± 1.30 mm for NDT method (p < 0.05). For reposition accuracy, the average registration error and RMS values were calculated as 1.41 ± 0.98 mm and 2.53 ± 1.64 mm using ICP method, and 0.92 ± 0.61 mm and 1.75 ± 0.80 mm using NDT method (p = 0.005). The overall target accuracy using the NDT method reduced the average of the reposition error and overall RMS value by 0.71 and 1.32 mm, respectively, compared to the ICP method (p = 0.03). CONCLUSIONS We found that the surface registration algorithm based on NDT method provides more reliable accuracy in the values of surface model, reposition, and target accuracies than the classic ICP method. The NDT method in OSI systems offers reasonable accuracy in SBRT/SRS.
Collapse
Affiliation(s)
- Haenghwa Lee
- Department of Neurosurgery, Neuroscience, & Radiosurgery Hybrid Research Center, Inje University Ilsan Paik Hospital, College of Medicine, Goyang, Republic of Korea
| | - Jeong-Mee Park
- Department of Neurosurgery, Neuroscience, & Radiosurgery Hybrid Research Center, Inje University Ilsan Paik Hospital, College of Medicine, Goyang, Republic of Korea
| | - Kwang Hyeon Kim
- Department of Neurosurgery, Neuroscience, & Radiosurgery Hybrid Research Center, Inje University Ilsan Paik Hospital, College of Medicine, Goyang, Republic of Korea
| | - Dong-Hoon Lee
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Moon-Jun Sohn
- Department of Neurosurgery, Neuroscience, & Radiosurgery Hybrid Research Center, Inje University Ilsan Paik Hospital, College of Medicine, Goyang, Republic of Korea
| |
Collapse
|
245
|
Miura H. [5. Robust Techniques for Radiotherapy Treatment Plan]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022; 78:882-888. [PMID: 35989258 DOI: 10.6009/jjrt.2022-2072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
|
246
|
Impact of stringent tolerance criteria on verification of absorbed dose distributions and evaluation through inhomogeneous media. NUCLEAR TECHNOLOGY AND RADIATION PROTECTION 2022. [DOI: 10.2298/ntrp2202138o] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Advances of radiation delivery devices have increased the complexity of the
radiation oncology treatments. Herewith, outcome of the treatment, as well
as patient safety, strongly depend on the consistency of absorbed dose
delivery. Both can be ensured by comprehensive system of verification of
calculated absorbed dose distributions. Standard method is evaluation of
calculated absorbed dose distribution according to gamma method, using a 2-D
detector and a homogeneous phantom, to obtain measured dose distribution.
Purpose of this research was to investigate the influence of tolerance
criteria on gamma passing rate. Additionally, the agreement in heterogeneous
phantom was analysed. Absorbed dose calculations were performed using systems Monaco and XiO. Detector with 1020 ionization chambers in homogeneous
phantom and semi-anthropomorphic phantom was used for measurements. Absorbed
dose distributions of around 3500 patients were analysed using gamma method.
In homogeneous phantom, average gamma passing rates were within tolerance
for 3 %/2 mm. For measurements in heterogeneous media, the highest average
gamma passing rate was obtained for small volumes of medium treatment
complexity (??=93.84%), while large volumes of treatment with low
complexity yielded the lowest gamma passing rates (??= 83.22%).
Collapse
|
247
|
Tatsumi D. [2. Considerations for Radiation Treatment Planning from Medical Accelerators]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022; 78:526-530. [PMID: 35598962 DOI: 10.6009/jjrt.2022-2018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
|
248
|
Sakamoto T, Matsumoto K, Otsuka M, Nanbu H, Okumura M. [Gantry QA Using Three-dimensional Diode Array Detector on O-ring Linear Accelerator]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022; 78:263-269. [PMID: 35314535 DOI: 10.6009/jjrt.780303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
PURPOSE It is necessary to perform gantry quality assurance (QA) in high precision radiotherapy. However, the O-ring type linear accelerator (Halcyon) does not have a light field and laser as a reference of isocenter point. The aim of this study is to investigate the usefulness of a three-dimensional diode array detector for gantry angle QA, and an O-ring type linear accelerator. METHOD The gantry angle and rotational center were verified using the ArcCHECK 3D diode array on the general linear accelerator (TrueBeam) as a reference and Halcyon. The gantry angles were measured at 0, 90, 180, and 270°. The accuracy of the gantry rotational center was evaluated using rotational irradiation in the clockwise and counterclockwise directions between 181° and 179°. RESULTS The QA system with ArcCHECK was able to apply on the TrueBeam and Halcyon. As a result of the accuracy of the gantry angle, the maximum error of value calculated from ArcCHECK was 0.1° compared with the nominal gantry angle of Halcyon. As a result of the accuracy of the gantry rotation isocenter of Halcyon, the distance between the isocenter and the gantry rotation center was 0.45 mm and 0.41 mm in the clockwise and counterclockwise directions, respectively. CONCLUSION The QA system with ArcCHECK was useful for the gantry angle and the rotation center accuracy on the Halcyon.
Collapse
Affiliation(s)
| | | | | | | | - Masahiko Okumura
- Department of Radiological Sciences, Morinomiya University of Medical Sciences
| |
Collapse
|
249
|
Saglam Y, Samanci Y, Bolukbasi Y, Peker S. Dosimetric comparison of volumetric modulated arc therapy with TrueBeam LINAC and hypofractionated radiosurgery with gamma knife ICON for large (>10 cm3) skull base meningiomas. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2022; 30:1201-1211. [PMID: 36189527 DOI: 10.3233/xst-221264] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
BACKGROUND Multi Fractionated stereotactic radiosurgery (MF-SRS) of Linac has an essential role in the treatment of skull base meningiomas (sbMNG). However, Gamma Knife Icon (GK) allows MF-SRS using mask immobilization with onboard image guidance. OBJECTIVE This dosimetric study aims to investigate whether equivalent plan quality can be achieved with Volumetric Modulated Arc Therapy (VMAT) in patients with large sbMNG (>10 cm3) previously treated with GK. METHODS Twenty patients with the median target volume of 19.7cm3 are re-planned by using VMAT with 20 Gy in 5 fractions. Plan qualities are compared to tumor coverage, paddick conformity index (PCI), gradient index (GI), V4 Gy, V10 Gy, V12 Gy, optic chiasm V20 Gy, brainstem V23 Gy, optic nerve V25 Gy volumes, and maximum doses for all. Additionally, beam-on time and approximate planning time are also analyzed and compared. RESULTS All plans provide adequate clinical requirements. First, the CI is comparable for the GK and VMAT (0.99±0.01 vs. 1.13±0.20; p = 0.18). Second, VMAT has a significantly higher GI than GK (3.81±0.35 vs. 2.63±0.09; p < 0.001). Third, the PCI is significantly higher in GK than VMAT (0.76±0.05 vs. 0.70±0.07; p < 0.001). The lower GI of the GK also results in significantly lower V4 Gy (156.1±43.8 vs. 207.5±40.1 cm3, p < 0.001) and V10 Gy (26.1±9.0 vs. 28.9±7.7 cm3, p < 0.001) compared to VMAT. Last, the VMAT reduces beam-on time (4.8±0.5 vs. 19±1.1 min.; p < 0.001). CONCLUSION Although both systems have succeeded in creating effective plans in clinical practice, the GK reveals more effective lower normal brain tissue doses. However, the shorter treatment time with LINAC, excluding the total procedure time, can be considered advantageous over GK.
Collapse
Affiliation(s)
- Yucel Saglam
- Department of Radiation Oncology, Koc University, School of Medicine, Davutpasa Caddesi, Topkapi, Istanbul, Turkey
| | - Yavuz Samanci
- Department of Neurosurgery, Koc University, School of Medicine, Davutpasa Caddesi, Topkapi, Istanbul, Turkey
| | - Yasemin Bolukbasi
- Department of Radiation Oncology, Koc University, School of Medicine, Davutpasa Caddesi, Topkapi, Istanbul, Turkey
| | - Selcuk Peker
- Department of Neurosurgery, Koc University, School of Medicine, Davutpasa Caddesi, Topkapi, Istanbul, Turkey
| |
Collapse
|
250
|
Sharma R, Sharma S, Agarwal P, Avasthi D, Verma R. Evaluating the impact of ionization chamber-specific beam quality correction factor in dosimetry of filtered and unfiltered photon beams. J Med Phys 2022; 47:159-165. [PMID: 36212211 PMCID: PMC9542991 DOI: 10.4103/jmp.jmp_101_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 06/06/2022] [Accepted: 06/20/2022] [Indexed: 11/30/2022] Open
Abstract
Aim: The response of ionization chamber changes when used at beam quality Q which is different from beam quality Qo (usually 60Co) that was used at the time of its calibration. Hence, one needs to apply beam quality correction factor (kQ, Qo) during dosimetric measurements. However, kQ, Qo data are unavailable for novel ion chambers in the literature. Moreover, most of such data do not differentiate between filtered (flat) and unfiltered (unflat) beams. In addition, literature-based data do not differentiate among different pieces of the ion chambers of the same make and model. Hence, the purpose of our study was to determine the ion chamber-specific experimental values of kQ, Qo and to evaluate their impact in dosimetry. Materials and Methods: In this work, the value of kQ, Qo were measured for six ionization chambers of three different types in 6, 10, and 15 MV filtered (with flattening filter [WFF]) as well as 6 and 10 MV unfiltered (flattening filter free [FFF]) photon beams. The measured values of kQ, Qo were compared with Monte Carlo-calculated values available in the literature. The uncertainties in measurement of kQ, Qo values were also evaluated. Results: For 6 MV FFF beam, the measured value of kQ, Qo was found to be consistently lower than 6 MV WFF beam for all Sun Nuclear Corporation ion chambers, while it was higher as per the theoretical data. The inter-chamber variation in kQ, Qo values was observed for the same model of the ion chambers. The maximum difference between absolute dose values on using the theoretical and experimental kQ, Qo values was up to 3.23%. Conclusion: The measured absolute dose values by the ion chamber of a given make and model were found different due to the use of its theoretical and experimental kQ, Qo values. Furthermore, the variation in response of different pieces of ion chambers of the same make and model cannot be accounted for theoretically, and hence, the use of theoretical kQ, Qo data may introduce an inherent error in the estimation of absorbed dose to water. This necessitates the use of measured value of kQ, Qo for each ionization chamber.
Collapse
|