301
|
Chiuch A, De Biasi M, Sossi D, Pecci R, Bedini R, Somma F, Angerame D. Nuovi e vecchi concetti in Endodonzia: il sistema Reciproc. GIORNALE ITALIANO DI ENDODONZIA 2013. [DOI: 10.1016/j.gien.2013.05.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
|
302
|
Leonardi DP, Sydney GB, Tanomaru Filho M, Baratto-Filho F, Baratto SSP, Cerri PS. Performance of RaCe Instrumentation System in Curved Root Canals: A Comprehensive Analysis by Three Study Methods. Braz Dent J 2013; 24:230-4. [DOI: 10.1590/0103-6440201301920] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2011] [Indexed: 11/21/2022] Open
Abstract
In this study, curved maxillary molar root canals were instrumented with RaCe rotary system to evaluate: 1. the occurrence of canal transportation using a radiographic platform; 2. the action of the instruments on the dentin walls, centering ability and canal enlargement by analysis of digital images; and the percentage of regular dentin surfaces and debris within the canal by histological analysis. Ten mesiobuccal roots of extracted human maxillary molars were embedded in acrylic resin and sectioned at the middle and apical thirds. Root canal shaping was performed using the RaCe rotary system at 250 rpm and 1 Ncm torque. Each instrument set was used five times according to a crown-down technique in the following sequence: 40/0.10, 35/0.08, 25/0.06, 25/0.04, 25/0.02 (working length - WL), 30/0.02 (WL) and 35/0.02 (WL). Each instrument was inserted until resistance was felt and then pulled back, followed by brushing movements towards all canal walls. Each specimen was assessed by three study methods: radiographic platform, digitized image assessment and histological analysis. The radiographic platform showed lack of apical transportation. No statistically significant difference (Wilcoxon test, p>0.05) was found between the middle and apical thirds regarding instrument action on dentin walls, centering ability, area of root canal enlargement, percentage of regular dentin surfaces and debris within the root canal. It may be concluded that RaCe system is a suitable method for the preparation of curved root canals, regarding the maintenance of root canal original path, action on dentin walls, canal enlargement and removal of debris from the root canal lumen.
Collapse
|
303
|
Silva e Souza PAR, das Dores RSE, Tartari T, Pinheiro TPS, Tuji FM, Silva e Souza MH. Effects of sodium hypochlorite associated with EDTA and etidronate on apical root transportation. Int Endod J 2013; 47:20-5. [PMID: 23710836 DOI: 10.1111/iej.12118] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2012] [Accepted: 04/03/2013] [Indexed: 11/30/2022]
Abstract
AIM To evaluate the influence of sodium hypochlorite associated with EDTA and etidronate on apical root transportation. METHODOLOGY Forty-five roots of human mandibular molars with curvatures of 15-25° were embedded in acrylic resin to allow standardized angulation of the initial and final radiographs. The pre-instrumentation radiographs of the mesiobuccal canal of each root were taken using a radiograph digital sensor with a size 15 K-file in the canal. The canals were prepared with the ProTaper Universal system (Dentsply Maillefer, Ballaigues, Switzerland), using one of the following irrigation regimens during the instrumentation (n = 15): G1 - irrigation with 20 mL of saline solution (control); G2 - alternating irrigation with 2.5% hypochlorite solution (NaOCl) (15 mL); and 17% ethylenediaminetetraacetic acid (EDTA) (5 mL). During instrumentation, the canal was filled with NaOCl and then between each exchange of instrument filled with EDTA for 1 min, and G3 - irrigation with 20 mL of 5% NaOCl and 18% etidronate solution (HEBP) mixed in equal parts. The postinstrumentation radiographs were made with a F3 instrument in the canal. The images were magnified and superposed with Adobe Photoshop software (Adobe Systems, Mountain View, CA, USA). Apical transportation was determined with AutoCAD 2012 software (Autodesk Inc., San Rafael, CA, USA) by measuring the distance in millimetres between the tips of the instruments. The results were subjected to the nonparametric statistical Kruskal-Wallis test (α < 0.05). RESULTS The median transportation and interquartile range values were 0.00 ± 0.05 for G1, 0.08 ± 0.23 for G2 and 0.13 ± 0.14 for G3. Comparison between groups showed that apical transportation in G3 was significantly greater than in G1 (P < 0.05). CONCLUSION The use of NaOCl associated with etidronate increased apical transportation in the canals of extracted teeth.
Collapse
Affiliation(s)
- P A R Silva e Souza
- Department of Endodontics, Dental School, Federal University of Pará, Belém, Brazil
| | | | | | | | | | | |
Collapse
|
304
|
Shen Y, Gao Y, Lin J, Ma J, Wang Z, Haapasalo M. Methods and models to study irrigation. ACTA ACUST UNITED AC 2013. [DOI: 10.1111/etp.12029] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
305
|
|
306
|
Rödig T, Kupis J, Konietschke F, Dullin C, Drebenstedt S, Hülsmann M. Comparison of hand and rotary instrumentation for removing gutta-percha from previously treated curved root canals: a microcomputed tomography study. Int Endod J 2013; 47:173-82. [PMID: 23701239 DOI: 10.1111/iej.12128] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2012] [Accepted: 04/17/2013] [Indexed: 12/25/2022]
Abstract
AIM To compare the efficacy of hand and rotary nickel-titanium (NiTi) instruments in removing filling material from curved root canals of root filled teeth with unknown preparation parameters. METHODOLOGY Ninety mandibular molars with root fillings in curved root canals and homogenous root canal filling extending to 0-2 mm short of the radiographic apex were selected. Root canal curvatures and radii were measured in two directions and microcomputed tomography (micro-CT) scans were used to determine preoperative volumes of the filling material. Subsequently, the teeth were assigned to two identical groups (n = 14). The root fillings were removed with Hedström files or FlexMaster NiTi rotary instruments. Postoperative micro-CT imaging was used to assess the percentage of residual filling material as well as the amount of dentine removal. Working time and procedural errors were recorded. Data were compared using analysis of covariance and analysis of variance procedures. RESULTS Root canals retreated with Hedström files were associated with less remaining filling material compared with FlexMaster instruments (P < 0.05). Both retreatment techniques removed similar amounts of dentine with no significant differences (P > 0.05). FlexMaster instruments were significantly faster than Hedström files (P < 0.05). No procedural errors were detected in the Hedström group, whilst three instruments fractured in the FlexMaster group. CONCLUSIONS Hand instrumentation resulted in significantly less residual filling material than retreatment with rotary NiTi instruments. Dentine removal was not significantly different for both techniques. FlexMaster NiTi rotary files were significantly faster than Hedström files, but were associated with a higher risk of instrument fracture.
Collapse
Affiliation(s)
- T Rödig
- Department for Preventive Dentistry, Periodontology and Cariology, University of Göttingen, Göttingen, Germany
| | | | | | | | | | | |
Collapse
|
307
|
Domark JD, Hatton JF, Benison RP, Hildebolt CF. An ex vivo comparison of digital radiography and cone-beam and micro computed tomography in the detection of the number of canals in the mesiobuccal roots of maxillary molars. J Endod 2013; 39:901-5. [PMID: 23791260 DOI: 10.1016/j.joen.2013.01.010] [Citation(s) in RCA: 83] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2012] [Revised: 01/17/2013] [Accepted: 01/30/2013] [Indexed: 10/26/2022]
Abstract
INTRODUCTION The purpose of this study was to compare digital periapical and cone-beam computed tomography (CBCT) images to determine the number of canals in the mesiobuccal root of maxillary molars and to compare these counts with micro computed tomography (μCT), which was also used to determine canal configuration. METHODS Digital periapical (RVG 6100), CBCT (9000 3D), and μCT images (the reference standard) were obtained of 18 hemi-maxillas. With periapical and CBCT images, 2 endodontists independently counted the number of canals in each molar and repeated the counts 2 weeks later. Teeth were extracted and scanned with μCT, and 2 additional endodontists, by consensus, determined the number and configuration of canals. The Friedman test was used to test for differences. RESULTS In mesiobuccal roots, 2 canals were present in 100% of maxillary first molars (13 of 13) and 57% of second molars (8 of 14), and 69% (9 of 13) and 100% (8 of 8) of these exited as 2 or more foramina. There was no difference in canal counts for original and repeat reads by the 2 observers with periapical (P = .06) and with CBCT (P = .88) and no difference when CBCT counts were compared with μCT counts (P = .52); however, when periapical counts were compared with μCT counts, there was a significant difference (P = .04). CONCLUSIONS For cadaver maxillary molars, μCT canal counts were significantly different from digital periapical radiograph counts but not different from Carestream9000 3D CBCT counts.
Collapse
Affiliation(s)
- Jeffrey D Domark
- Department of Endodontics, Center for Advanced Dental Education, Saint Louis University, St Louis, MO 63104, USA
| | | | | | | |
Collapse
|
308
|
Markvart M, Dahlén G, Reit CE, Bjørndal L. The antimicrobial effect of apical box versus apical cone preparation using iodine potassium iodide as root canal dressing: a pilot study. Acta Odontol Scand 2013; 71:786-91. [PMID: 23126492 DOI: 10.3109/00016357.2012.734400] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE The purpose was to study the reduction of intra-canal microflora in premolars with apical periodontitis instrumented with either apical box or apical cone preparation and to provide measurements of intervention effects to allow proper power calculation in future clinical trials. METHODS Twenty-four patients were centrally randomized to apical box preparation (size #60) or cone preparation (apical size #25). The groups were comparable regarding the presence of primary caries and type of coronal restoration. In the course of canal preparation each tooth was irrigated with 2.5% NaOCl (12 ml). Lastly, the canals were filled with 17% EDTA (2 × 30 s) and 5% iodine potassium iodide (IKI) for 10 min. The canals were sampled for micro-organisms on four occasions: before instrumentation, after instrumentation, after application of IKI dressing and at the beginning of the second appointment 1 week later. Between the treatment sessions, the root canals were sealed with IRM cement. In the laboratory, culture techniques were used to measure microbial growth, which was classified as: none, very sparse, sparse, moderate, heavy or very heavy. RESULTS Initially, microbes were recovered in 88% of the teeth. Growth was classified as none in 35% of the teeth after instrumentation and in 50% after the application of IKI. Irrespective of the time of sampling, no significant difference in microbial growth reduction was observed between the two types of apical preparation. Based on the 1-week post-sampling, a power calculation revealed that over 900 patients are needed to show a difference of 9% between the two protocols tested. CONCLUSIONS Future trials should be conducted using stringent protocols and as multi-centre trials for reaching the required information size.
Collapse
Affiliation(s)
- Merete Markvart
- Department of Odontology, Cariology, Endodontics, Pediatric Dentistry and Clinical Genetics, School of Dentistry, Faculty of Health Sciences, University of Copenhagen, Denmark.
| | | | | | | |
Collapse
|
309
|
Kakar S, Dhingra A, Sharma H. Shaping potential of manual NiTi K-File and rotary ProTaper and analyzing the final outcome of shaped canals using CT. J Contemp Dent Pract 2013; 14:451-455. [PMID: 24171988 DOI: 10.5005/jp-journals-10024-1343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
AIM To assess and compare the shaping potential of manual NiTi K-files and Rotary ProTaper instruments in narrow canals using CT. OBJECTIVE To assess the shaping potential of manual NiTi K-files and Rotary ProTaper and analyzing the final outcome of shaped canals using CT and determining different variables, like • Working time • Change in volume • Change in cross-sectional area. MATERIALS AND METHODS From a pool of fifty freshly extracted permanent maxillary molars (1st and 2nd), 30 were selected with curvatures (20 to 40°) (Schneider 1971). Tissue fragments and calcified debries were removed from the teeth by scaling. The teeth were then stored in normal saline until used. All the mesiobuccal canals were scanned by CT to obtain preinstrumented images. Teeth were scaled and stored in normal saline. This study was divided in two groups with 15 samples each. GROUP I (PROTAPER ROTARY): Canals were instrumented with Protaper Rotary instruments using crown down technique according to manufacturer's instructions. GROUP II (NITI K-FILE): Were instrumented by NiTi K-files using step back technique with a quarter turn/pull motion. EVALUATIONS OF WORKING TIME: Comparative evaluations of working time was done for both the experimental groups. CT ANALYSIS AND MEASUREMENTS: The samples were analyzed and evaluated for: • Postinstrumentation change in volume. • Postinstrumentation change in cross-sections area. RESULT From the observations and statistical analysis carried out in this study, it was found that: There was a statistically significant difference between all the parameters judged for the present study that is: 1. Instrumentation with ProTaper Rotary system took significantly less time than instrumentation with manual NiTi K-file. 2. Change in the canal volume following instrumentation with ProTaper Rotary was significantly greater than that produced by manual NITi K-file. 3. a. Change in cross-section area at 2 and 3 mm from the apex was significantly greater with manual NiTi K-file as compared to ProTaper Rotary. b. Change in cross sections at 4.5, 6 and 7.5 mm from the apex with ProTaper Rotary was significantly greater than that produced by manual NITi K-file. CONCLUSION This clearly establishes that there is a drastic difference in the shaping ability of manual and Rotary NiTi instruments used with step back and crown down technique respectively with the rotary instrumentation being faster and producing greater changes in the canal anatomy.
Collapse
Affiliation(s)
- Surbhi Kakar
- Senior Resident, Department of Endodontics, Maulana Azad Institute of Dental Sciences, New Delhi, India
| | | | | |
Collapse
|
310
|
Spoorthy E, Velmurugan N, Ballal S, Nandini S. Comparison of irrigant penetration up to working length and into simulated lateral canals using various irrigating techniques. Int Endod J 2013; 46:815-22. [DOI: 10.1111/iej.12065] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2012] [Accepted: 01/10/2013] [Indexed: 11/29/2022]
Affiliation(s)
- E. Spoorthy
- Department of Conservative Dentistry and Endodontics; Meenakshi Ammal Dental College and Hospital; Meenakshi University; Chennai; India
| | - N. Velmurugan
- Department of Conservative Dentistry and Endodontics; Meenakshi Ammal Dental College and Hospital; Meenakshi University; Chennai; India
| | - S. Ballal
- Department of Conservative Dentistry and Endodontics; Meenakshi Ammal Dental College and Hospital; Meenakshi University; Chennai; India
| | - S. Nandini
- Department of Conservative Dentistry and Endodontics; Meenakshi Ammal Dental College and Hospital; Meenakshi University; Chennai; India
| |
Collapse
|
311
|
Effect of the Source of Biofilm Bacteria, Level of Biofilm Maturation, and Type of Disinfecting Agent on the Susceptibility of Biofilm Bacteria to Antibacterial Agents. J Endod 2013; 39:473-7. [DOI: 10.1016/j.joen.2012.11.024] [Citation(s) in RCA: 124] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2012] [Revised: 11/09/2012] [Accepted: 11/12/2012] [Indexed: 11/18/2022]
|
312
|
Meire MA, Poelman D, De Moor RJ. Optical properties of root canal irrigants in the 300-3,000-nm wavelength region. Lasers Med Sci 2013; 29:1557-62. [PMID: 23532580 DOI: 10.1007/s10103-013-1307-4] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2012] [Accepted: 03/11/2013] [Indexed: 11/30/2022]
Abstract
In root canal therapy, irrigating solutions are essential to assist in debridement and disinfection. Their spread and action is often restricted by canal anatomy, requiring some form of activation. Lasers have been shown to be promising tools for this purpose (laser-activated irrigation (LAI)). For LAI to be effective, high absorption of radiation in the irrigant is essential. Although the absorption spectrum of water is well established, little is known about the optical properties of other irrigating solutions. Therefore, root canal irrigants (sodium hypochlorite (NaOCl), citric acid (CA), chlorhexidine (CHX), ethylenediaminetetraacetate (EDTA), water) were subjected to UV/Vis spectrophotometry in the 300-3,000-nm region using synthetic quartz cells with an optical path length of 1 mm. Transmission data were used to plot the transmission spectrum and calculate the absorption coefficient (α) of each irrigant. The transmission spectra of the tested solutions proved to follow the spectrum of pure water to a large extent. All tested solutions displayed absorption peaks around 1,450 nm (α ≈ 14 cm(-1)), 1,950 nm (α > 30 cm(-1)), and above 2,500 nm (α > 30 cm(-1)). NaOCl showed higher absorption than water in the UV region. Slightly higher absorption than water was noted for CHX (Corsodyl) around 513 nm and for CA between 1,600 and 1,800 nm and around 2,200 nm. The absorption in all tested solutions for wavelengths greater than 2,500 nm is very high, meaning a great potential for laser-activated irrigation. Other wavelengths eligible for LAI are located around 1,450 and 2,000 nm but require further investigation.
Collapse
Affiliation(s)
- Maarten A Meire
- Department of Restorative Dentistry and Endodontology, Dental School, Ghent University Hospital, Ghent University, De Pintelaan 185/P8, 9000, Gent, Belgium,
| | | | | |
Collapse
|
313
|
Zhao D, Shen Y, Peng B, Haapasalo M. Micro–Computed Tomography Evaluation of the Preparation of Mesiobuccal Root Canals in Maxillary First Molars with Hyflex CM, Twisted Files, and K3 Instruments. J Endod 2013; 39:385-8. [DOI: 10.1016/j.joen.2012.11.030] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2012] [Revised: 11/11/2012] [Accepted: 11/12/2012] [Indexed: 12/01/2022]
|
314
|
Self-Adjusting File Cleaning-Shaping-Irrigation System Improves Root-filling Bond Strength. J Endod 2013; 39:254-7. [DOI: 10.1016/j.joen.2012.10.026] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2012] [Revised: 10/10/2012] [Accepted: 10/18/2012] [Indexed: 11/20/2022]
|
315
|
Ceyhanli KT, Erdilek N, Tatar I, Cetintav B. Comparative micro-computed tomography evaluation of apical root canal transportation with the use of ProTaper, RaCe and Safesider systems in human teeth. AUST ENDOD J 2013; 40:12-6. [PMID: 24697959 DOI: 10.1111/aej.12014] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
The aim of this study was to compare apical centring ability of nickel titanium (NiTi) ProTaper, RaCe and mainly stainless steel Safesider systems using micro-computed tomography. Thirty freshly extracted mandibular molars with two separate mesial canals and separate foramina were used for the study. Mesial roots were embedded in acrylic resin and instrumented with the ProTaper, RaCe or Safesider systems. Root canal transportation and centring ability of the instruments were evaluated using superimposed micro-computed tomography images of the apical 4 mm of the roots taken at 1 mm intervals. One-way analysis of variance and post hoc Tukey's tests were performed to compare apical transportations. Significant differences were observed between groups at the apical 1, 2 and 3 mm levels (P < 0.05). The reciprocating Safesider system transported root canals significantly more than the other two NiTi systems in the apical 1 mm level (P = 0.001) and more than RaCe system in the apical 2 mm level (P = 0.003). The ProTaper instruments caused more apical root canal transportation than did RaCe instruments at apical 3 mm (P = 0.045). NiTi instrumentation systems showed better centring ability than the mainly stainless steel Safesider system because of the flexible structure of the NiTi alloy.
Collapse
Affiliation(s)
- Kadir T Ceyhanli
- Department of Endodontics, Faculty of Dentistry, Karadeniz Technical University, Trabzon, Turkey
| | | | | | | |
Collapse
|
316
|
Boutsioukis C, Psimma Z, van der Sluis LWM. Factors affecting irrigant extrusion during root canal irrigation: a systematic review. Int Endod J 2013; 46:599-618. [DOI: 10.1111/iej.12038] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2012] [Accepted: 11/08/2012] [Indexed: 11/29/2022]
Affiliation(s)
- C. Boutsioukis
- Physics of Fluids Group; Faculty of Science and Technology, and MESA+ Institute for Nanotechnology; University of Twente; Enschede; the Netherlands
| | - Z. Psimma
- Department of Endodontology; Dental School; Aristotle University of Thessaloniki; Thessaloniki; Greece
| | - L. W. M. van der Sluis
- Department of Conservative Dentistry and Endodontics; Paul Sabatier University; Toulouse; France
| |
Collapse
|
317
|
Ruckman JE, Whitten B, Sedgley CM, Svec T. Comparison of the Self-Adjusting File with Rotary and Hand Instrumentation in Long-oval–shaped Root Canals. J Endod 2013; 39:92-5. [DOI: 10.1016/j.joen.2012.07.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2012] [Revised: 07/11/2012] [Accepted: 07/26/2012] [Indexed: 11/28/2022]
|
318
|
Radiographic examination of apical extrusion of root canal irrigants during cavitation induced by Er,Cr:YSGG laser irradiation: an in vivo study. Clin Oral Investig 2012; 17:2105-12. [DOI: 10.1007/s00784-012-0910-2] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2012] [Accepted: 12/09/2012] [Indexed: 10/27/2022]
|
319
|
Lin J, Shen Y, Haapasalo M. A comparative study of biofilm removal with hand, rotary nickel-titanium, and self-adjusting file instrumentation using a novel in vitro biofilm model. J Endod 2012; 39:658-63. [PMID: 23611386 DOI: 10.1016/j.joen.2012.11.012] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2012] [Revised: 11/03/2012] [Accepted: 11/06/2012] [Indexed: 11/25/2022]
Abstract
INTRODUCTION This study sought to present a standardized biofilm model in extracted teeth with an artificial apical groove to quantify the efficacy of hand, rotary nickel-titanium, and self-adjusting file (SAF) instrumentation in biofilm bacteria removal. METHODS Thirty-six extracted single-rooted teeth with oblong canals were selected. Each tooth was split longitudinally, and a 0.2-mm-wide groove was placed in the apical 2 to 5 mm of the canal. After growing mixed bacteria biofilm inside the canal under an anaerobic condition, the split halves were reassembled in a custom block, creating an apical vapor lock. Teeth were randomly divided into 3 treatment groups (n = 10 per group) using the K-file, ProFile (Dentsply Tulsa Dental Products, Tulsa, OK), and the SAF (ReDent-Nova, Ra'anana, Israel). Irrigation consisted of 10 mL 3% NaOCl and 4 mL 17% EDTA. Six teeth received no treatment. Areas inside and outside the groove were examined using a scanning electron microscope. RESULTS The scanning electron microscope showed a consistently thick layer of biofilm grown in the canals of the control group after 4 weeks. Within the groove, a smaller area remained occupied by bacteria after the use of the SAF compared with the ProFile and the K-file (3.25%, 19.25%, and 26.98%, respectively; P < .05). For all groups, significantly more bacteria were removed outside the groove than inside (P < .05). No statistical differences were found outside the groove (P > .05). CONCLUSIONS Although all techniques equally removed bacteria outside the groove, the SAF reduced significantly more bacteria within the apical groove. No technique was able to remove all bacteria. This biofilm model represents a potentially useful tool for the future study of root canal disinfection.
Collapse
Affiliation(s)
- James Lin
- Division of Endodontics, Department of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, British Columbia, Canada
| | | | | |
Collapse
|
320
|
Narayan GS, Venkatesan SM, Karumaran CS, Indira R, Ramachandran S, Srinivasan MR. A comparative evaluation on the cleaning and shaping ability of three nickel titanium rotary instruments using computerized tomography - An ex vivo study. Contemp Clin Dent 2012; 3:S151-5. [PMID: 23230351 PMCID: PMC3514944 DOI: 10.4103/0976-237x.101070] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Introduction: Successful root canal treatment depends primarily on the removal of micro-organisms through chemo-mechanical instrumentation of the root canal system. This encompasses shaping by mechanical removal of the dentine and cleaning by chemical disinfection of microorganisms and dissolution of organic tissues from the root canal. While root canal shaping can be predictably and efficiently attained with advanced instrumentation technology, effective cleaning of the entire root canal system remains a challenge. Rotary nickel titanium instruments are known for their efficient preparation of root canal. This is mainly because of the super elasticity of the nickel titanium alloy which gives an increased flexibility and allows the instrument to efficiently follow the original path of root canal. The purpose of this study is to compare the cleaning efficiency and shaping ability of M two, K3, Race ni-ti rotary instruments during the preparation of curved canals in extracted molars. Materials and Methods: Thirty teeth with 18 mm as their working length were selected and divided into three groups of 10 teeth each Angle of curvature, Radius of curvature, was determined using computerized tomography. A Pre and Post-operative measurement of canal width and volume was recorded and compared using CT. The teeth was then sectioned into two halves and subjected to scanning electron microscope. Images were taken at the level of apical third, middle third and coronal third for debris and smear layer. Scoring was done separately for both debris and smear layer. Results: Results were tabulated and statistically analyzed to evaluate the shaping ability and cleaning efficiency. Instruments were examined for any deformation or fracture during canal preparation. Conclusion: M two showed greater enlargements in all the three levels, when compared its width and volume, with other two instruments. K3 was better than Race when compared among them. In the scanning electron microscope study for debris and smear layer M Two performed better followed by K3 and Race.
Collapse
Affiliation(s)
- Gopal S Narayan
- Department of Conservative Dentistry & Endodontics, Ragas Dental College and Hospital, Chennai, India
| | | | | | | | | | | |
Collapse
|
321
|
Canal and Isthmus Debridement Efficacy of the VPro EndoSafe Negative-pressure Irrigation Technique. J Endod 2012; 38:1631-4. [DOI: 10.1016/j.joen.2012.09.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2012] [Revised: 08/25/2012] [Accepted: 09/10/2012] [Indexed: 11/19/2022]
|
322
|
Celik D, Taşdemir T, Er K. Comparison of influence of different manufacturing methods on the cleaning efficiency of rotary nickel-titanium files. Microsc Res Tech 2012. [PMID: 23180471 DOI: 10.1002/jemt.22157] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The purpose of this study was to evaluate and compare cleaning effectiveness of TwistedFile, GT series X, Revo-S, RaCe, Mtwo, and ProTaper Universal rotary files in curved canals. Seventy mesiobuccal canals of extracted human first maxillary molars were divided into seven groups of 10 samples each. Canals were prepared with six nickel-titanium (NiTi) rotary systems and manual K-Flexofile. Irrigation was performed with 2 mL 2.5% NaOCl solution after each file, and 5 mL 2.5% NaOCl was used for the final flush. After the roots were split longitudinally, the presence of debris and smear layer was visualized using scanning electron microscopic photomicrographs taken at coronal, middle, and apical third. Mean scores for debris and the smear layer were calculated and statistically analyzed for significance between groups using the Kruskal-Wallis nonparametric analysis of variance (P < 0.05) and Mann-Whitney U test (P < 0.001). There was no significant difference among the groups in terms of debris and smear layer scores (P > 0.05). Without considering the preparation method used, while no statistically significant difference was found between the coronal third and the middle third (P > 0.05), higher amount of debris and smear layer were found in apical third (P = 0.001). The new generation of NiTi rotary files including the Twisted File and GT Series X presented similar cleaning effectiveness compared with traditionally ground NiTi rotary files.
Collapse
Affiliation(s)
- Davut Celik
- Department of Endodontics, Faculty of Dentistry, Karadeniz Technical University, Trabzon, Turkey
| | | | | |
Collapse
|
323
|
Bukiet F, Couderc G, Camps J, Tassery H, Cuisinier F, About I, Charrier A, Candoni N. Wetting Properties and Critical Micellar Concentration of Benzalkonium Chloride Mixed in Sodium Hypochlorite. J Endod 2012; 38:1525-9. [DOI: 10.1016/j.joen.2012.07.008] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2012] [Revised: 07/19/2012] [Accepted: 07/26/2012] [Indexed: 11/30/2022]
|
324
|
A micro-computed tomography study of canal configuration of multiple-canalled mesiobuccal root of maxillary first molar. Clin Oral Investig 2012; 17:1541-6. [DOI: 10.1007/s00784-012-0852-8] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2012] [Accepted: 09/25/2012] [Indexed: 10/27/2022]
|
325
|
Gandolfi MG, Parrilli AP, Fini M, Prati C, Dummer PMH. 3D micro-CT analysis of the interface voids associated with Thermafil root fillings used with AH Plus or a flowable MTA sealer. Int Endod J 2012; 46:253-63. [DOI: 10.1111/j.1365-2591.2012.02124.x] [Citation(s) in RCA: 96] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2012] [Accepted: 07/23/2012] [Indexed: 11/30/2022]
Affiliation(s)
- M. G. Gandolfi
- Laboratory of Biomaterials and Oral Pathology, Department of Odontostomatological Science; University of Bologna; Bologna; Italy; Italy
| | - A. P. Parrilli
- Laboratory of Preclinical and Surgical Studies; Rizzoli Orthopaedic Institute; Bologna; Italy
| | - M. Fini
- Laboratory of Preclinical and Surgical Studies; Rizzoli Orthopaedic Institute; Bologna; Italy
| | | | | |
Collapse
|
326
|
The effect of the NRT files instrumentation on the quality of the surface of the root canal wall. J Appl Biomater Funct Mater 2012; 10:136-40. [PMID: 22798244 DOI: 10.5301/jabfm.2012.9268] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/15/2011] [Indexed: 11/20/2022] Open
Abstract
PURPOSE To analyze in vitro, trough scanning electron microscope (SEM), the shaping ability of NRT NiTi rotary system (Mani, Inc, Toshigi-Ken, Japan). METHODS Ten extracted human teeth were cut at the level of the CEJ and prepared with Gates-Glidden burs 4-3-2 and NRT rotary files up to size #35. Irrigation was performed with 7.5 mL of 5% NaOCl and 7.5 mL of 10% EDTA during each canal instrumentation. Following the shaping sequence, a final irrigation was performed with EDTA followed by NaOCl, each left in situ for three minutes. Teeth were then fractured longitudinally, and the coronal, middle, and apical thirds of the canals were inspected with SEM. Three parameters, divided into four different levels (Alfa and Bravo, considered clinically acceptable; Charlie and Delta, considered clinically unacceptable), were used to score the canal morphology: presence and amount of smear layer; presence of organic and inorganic debris; surface profile. RESULTS SEM assessment revealed that in the coronal and middle third the majority of canals shaped with NRT rotary system presented a clinically acceptable surface. The apical third presented a higher amount of smear layer and dentinal debris instead, compared to the coronal and middle third. CONCLUSIONS NRT files demonstrated that they provided good instrumentation of the coronal and middle third, while being unable to obtain a defects-free surface in the apical third.
Collapse
|
327
|
|
328
|
Marca C, Dummer PMH, Bryant S, Vier-Pelisser FV, Só MVR, Fontanella V, Dutra VD, de Figueiredo JAP. Three-rooted premolar analyzed by high-resolution and cone beam CT. Clin Oral Investig 2012; 17:1535-40. [PMID: 22993113 DOI: 10.1007/s00784-012-0839-5] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2012] [Accepted: 09/04/2012] [Indexed: 10/27/2022]
Abstract
OBJECTIVES The aim of this study was to analyze the variations in canal and root cross-sectional area in three-rooted maxillary premolars between high-resolution computed tomography (μCT) and cone beam computed tomography (CBCT). MATERIALS AND METHODS Sixteen extracted maxillary premolars with three distinct roots and fully formed apices were scanned using μCT and CBCT. Photoshop CS software was used to measure root and canal cross-sectional areas at the most cervical and the most apical points of each root third in images obtained using the two tomographic computed (CT) techniques, and at 30 root sections equidistant from both root ends using μCT images. Canal and root areas were compared between each method using the Student t test for paired samples and 95 % confidence intervals. RESULTS Images using μCT were sharper than those obtained using CBCT. There were statistically significant differences in mean area measurements of roots and canals between the μCT and CBCT techniques (P < 0.05). Root and canal areas had similar variations in cross-sectional μCT images and became proportionally smaller in a cervical to apical direction as the cementodentinal junction was approached, from where the area then increased apically. CONCLUSION Although variation was similar in the roots and canals under study, CBCT produced poorer image details than μCT. CLINICAL RELEVANCE Although CBCT is a strong diagnosis tool, it still needs improvement to provide accuracy in details of the root canal system, especially in cases with anatomical variations, such as the three-rooted maxillary premolars.
Collapse
Affiliation(s)
- Caroline Marca
- Department of Endodontics, Graduate Program, School of Dentistry, Pontifical Catholic University of Rio Grande do Sul (PUCRS), Porto Alegre, Brazil.
| | | | | | | | | | | | | | | |
Collapse
|
329
|
Canal and Isthmus Debridement Efficacy Using a Sonic Irrigation Technique in a Closed-canal System. J Endod 2012; 38:1265-8. [DOI: 10.1016/j.joen.2012.05.009] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2012] [Revised: 05/22/2012] [Accepted: 05/23/2012] [Indexed: 11/17/2022]
|
330
|
Vera J, Siqueira JF, Ricucci D, Loghin S, Fernández N, Flores B, Cruz AG. One- versus Two-visit Endodontic Treatment of Teeth with Apical Periodontitis: A Histobacteriologic Study. J Endod 2012; 38:1040-52. [DOI: 10.1016/j.joen.2012.04.010] [Citation(s) in RCA: 206] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2012] [Revised: 04/06/2012] [Accepted: 04/10/2012] [Indexed: 10/28/2022]
|
331
|
Yamamura B, Cox TC, Heddaya B, Flake NM, Johnson JD, Paranjpe A. Comparing Canal Transportation and Centering Ability of EndoSequence and Vortex Rotary Files by Using Micro–Computed Tomography. J Endod 2012; 38:1121-5. [DOI: 10.1016/j.joen.2012.04.019] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2012] [Revised: 04/25/2012] [Accepted: 04/27/2012] [Indexed: 11/25/2022]
|
332
|
Dietrich MA, Kirkpatrick TC, Yaccino JM. In Vitro Canal and Isthmus Debris Removal of the Self-Adjusting File, K3, and WaveOne Files in the Mesial Root of Human Mandibular Molars. J Endod 2012; 38:1140-4. [DOI: 10.1016/j.joen.2012.05.007] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2012] [Revised: 05/10/2012] [Accepted: 05/17/2012] [Indexed: 10/28/2022]
|
333
|
Spagnuolo G, Ametrano G, D'Antò V, Rengo C, Simeone M, Riccitiello F, Amato M. Effect of autoclaving on the surfaces of TiN-coated and conventional nickel-titanium rotary instruments. Int Endod J 2012; 45:1148-55. [DOI: 10.1111/j.1365-2591.2012.02088.x] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2012] [Accepted: 05/27/2012] [Indexed: 11/29/2022]
Affiliation(s)
- G. Spagnuolo
- Department of Oral and Maxillofacial Sciences; University of Napoli “Federico II”; Napoli; Italy
| | - G. Ametrano
- Department of Oral and Maxillofacial Sciences; University of Napoli “Federico II”; Napoli; Italy
| | - V. D'Antò
- Department of Oral and Maxillofacial Sciences; University of Napoli “Federico II”; Napoli; Italy
| | - C. Rengo
- Department of Oral and Maxillofacial Sciences; University of Napoli “Federico II”; Napoli; Italy
| | - M. Simeone
- Department of Oral and Maxillofacial Sciences; University of Napoli “Federico II”; Napoli; Italy
| | - F. Riccitiello
- Department of Oral and Maxillofacial Sciences; University of Napoli “Federico II”; Napoli; Italy
| | - M. Amato
- Department of Medical School; University of Salerno; Salerno; Italy
| |
Collapse
|
334
|
Freire LG, Gavini G, Cunha RS, Santos MD. Assessing apical transportation in curved canals: comparison between cross-sections and micro-computed tomography. Braz Oral Res 2012; 26:222-7. [DOI: 10.1590/s1806-83242012000300007] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2012] [Accepted: 04/03/2012] [Indexed: 11/22/2022] Open
|
335
|
Jiang LM, Lak B, Eijsvogels LM, Wesselink P, van der Sluis LWM. Comparison of the cleaning efficacy of different final irrigation techniques. J Endod 2012; 38:838-41. [PMID: 22595122 DOI: 10.1016/j.joen.2012.03.002] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2011] [Revised: 03/05/2012] [Accepted: 03/11/2012] [Indexed: 11/24/2022]
Abstract
INTRODUCTION The aim of this study was to evaluate the removal of dentin debris from artificially made grooves in standardized root canals by 6 different final irrigation techniques. METHODS Conventional syringe irrigation, manual dynamic activation (MDA) with tapered or nontapered gutta-percha (GP) cones, the Safety Irrigator system, continuous ultrasonic irrigation (CUI), and apical negative pressure (ANP) irrigation were tested ex vivo in 20 root canals with a standardized, debris-filled groove in the apical portion of one canal wall. After each irrigation procedure, the groove was photographed, and the residual amount of dentin debris was scored. RESULTS There was no significant difference between the MDA with a nontapered GP cone, the Safety Irrigator, and the ANP irrigation. These techniques produced better cleaning efficacy than syringe irrigation (P < .005) but significantly worse than the MDA with a tapered cone (P < .05). CUI was significantly better than all the other techniques tested in this study (P < .001). CONCLUSIONS CUI was the most effective technique in dentin debris removal from the apical irregularities, and syringe irrigation alone was the least effective. MDA technique was more effective with a tapered GP cone than with a nontapered one.
Collapse
Affiliation(s)
- Lei-Meng Jiang
- Department of Endodontology, Academic Centre of Dentistry Amsterdam (ACTA), University of Amsterdam and VU University, Amsterdam, The Netherlands.
| | | | | | | | | |
Collapse
|
336
|
De-Deus G, Barino B, Marins J, Magalhães K, Thuanne E, Kfir A. Self-Adjusting File Cleaning-Shaping-Irrigation System Optimizes the Filling of Oval-shaped Canals with Thermoplasticized Gutta-percha. J Endod 2012; 38:846-9. [DOI: 10.1016/j.joen.2012.02.027] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2012] [Revised: 02/24/2012] [Accepted: 02/24/2012] [Indexed: 11/27/2022]
|
337
|
Evaluation of Antibacterial Effects by Atmospheric Pressure Nonequilibrium Plasmas against Enterococcus faecalis Biofilms In Vitro. J Endod 2012; 38:545-9. [DOI: 10.1016/j.joen.2011.10.021] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2011] [Revised: 10/23/2011] [Accepted: 10/26/2011] [Indexed: 11/21/2022]
|
338
|
Markvart M, Bjørndal L, Darvann TA, Larsen P, Dalstra M, Kreiborg S. Three-dimensional analysis of the pulp cavity on surface models of molar teeth, using X-ray micro-computed tomography. Acta Odontol Scand 2012; 70:133-9. [PMID: 21780969 DOI: 10.3109/00016357.2011.600707] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
AIM The purpose of this study was to investigate the scanning and segmentation precision of surface models of molars for the detection of small volumes, such as the reduced pulp cavity; formation of mineral deposits; detection of narrow root canals and to improve the clinical and morphological understanding of the number of root canals and their configuration. METHODS Eighteen human molars were scanned using X-ray micro-computed tomography. The reconstruction of the surface models had a precision of <1 voxel, using three-dimensional software and quantitative color mapping. In order to relate the measurements to changes over time the size of the pulp chambers was classified in two well-defined groups. RESULTS The mineral deposits were more evenly distributed in small pulp chambers than in large, but complete root canal calcification was never observed. No difference was observed in the material with respect to the presence of intra-radicular connections. In upper molars, a second mesiobuccal canal (mb(2)) frequency of 91% was found. The difference in length between the first mesiobuccal canal (mb(1)) and mb(2) was <1 mm. The number of root canals could be related to the number of root cones. CONCLUSION In summary, three-dimensional surface models were made with a high precision; an increased accumulation of mineral deposits was noted in molars with small pulp chambers and combined with the consistent pattern of intra-radicular connections, the potential endodontic treatment complexity is underlined in such cases. Finally, an improved understanding of root canal prevalence was reached, when merging well-defined definitions on root morphology and clinical classification systems.
Collapse
Affiliation(s)
- Merete Markvart
- Department of Cariology and Endodontics, School of Dentistry, University of Copenhagen, Copenhagen, Denmark.
| | | | | | | | | | | |
Collapse
|
339
|
Dentinal Tubule Infection as the Cause of Recurrent Disease and Late Endodontic Treatment Failure: A Case Report. J Endod 2012; 38:250-4. [DOI: 10.1016/j.joen.2011.10.019] [Citation(s) in RCA: 92] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2011] [Revised: 10/25/2011] [Accepted: 10/26/2011] [Indexed: 11/23/2022]
|
340
|
Rödig T, Hausdörfer T, Konietschke F, Dullin C, Hahn W, Hülsmann M. Efficacy of D-RaCe and ProTaper Universal Retreatment NiTi instruments and hand files in removing gutta-percha from curved root canals - a micro-computed tomography study. Int Endod J 2012; 45:580-9. [PMID: 22264204 DOI: 10.1111/j.1365-2591.2012.02014.x] [Citation(s) in RCA: 78] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
AIM To compare the efficacy of two rotary NiTi retreatment systems and Hedström files in removing filling material from curved root canals. METHODOLOGY Curved root canals of 57 extracted teeth were prepared using FlexMaster instruments and filled with gutta-percha and AH Plus. After determination of root canal curvatures and radii in two directions, the teeth were assigned to three identical groups (n = 19). The root fillings were removed with D-RaCe instruments, ProTaper Universal Retreatment instruments or Hedström files. Pre- and postoperative micro-CT imaging was used to assess the percentage of residual filling material as well as the amount of dentine removal. Working time and procedural errors were recorded. Data were analysed using analysis of covariance and analysis of variance procedures. RESULTS D-RaCe instruments were significantly more effective than ProTaper Universal Retreatment instruments and Hedström files (P < 0.05). Hedström files removed significantly less dentine than the rotary NiTi systems (P < 0.0001). D-RaCe instruments were significantly faster compared to both other groups (P < 0.05). No procedural errors such as instrument fracture, blockage, ledging or perforation were detected in the Hedström group. In the ProTaper group, four instrument fractures and one lateral perforation were observed. Five instrument fractures were recorded for D-RaCe. CONCLUSIONS D-RaCe instruments were associated with significantly less residual filling material than ProTaper Universal Retreatment instruments and hand files. Hedström files removed significantly less dentine than both rotary NiTi systems. Retreatment with rotary NiTi systems resulted in a high incidence of procedural errors.
Collapse
Affiliation(s)
- T Rödig
- Department of Preventive Dentistry, Periodontology and Cariology, University of Göttingen, Göttingen Centre for Statistics, University of Göttingen, Germany.
| | | | | | | | | | | |
Collapse
|
341
|
Stern S, Patel S, Foschi F, Sherriff M, Mannocci F. Changes in centring and shaping ability using three nickel-titanium instrumentation techniques analysed by micro-computed tomography (μCT). Int Endod J 2012; 45:514-23. [DOI: 10.1111/j.1365-2591.2011.02004.x] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
342
|
Irrigation Trends among American Association of Endodontists Members: A Web-based Survey. J Endod 2012; 38:37-40. [DOI: 10.1016/j.joen.2011.08.013] [Citation(s) in RCA: 161] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2011] [Revised: 08/08/2011] [Accepted: 08/09/2011] [Indexed: 11/17/2022]
|
343
|
Bürklein S, Hinschitza K, Dammaschke T, Schäfer E. Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper. Int Endod J 2011; 45:449-61. [DOI: 10.1111/j.1365-2591.2011.01996.x] [Citation(s) in RCA: 289] [Impact Index Per Article: 20.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
344
|
Abstract
The aim of this paper is to present the contemporary developments in root canal treatment, restoration of the endodontically treated tooth, and advanced endodontic procedures, such as root canal retreatment and surgical endodontics.
Collapse
|
345
|
Microscopic computerized tomographic evaluation of root canal transportation prepared with twisted or ground nickel-titanium rotary instruments. ACTA ACUST UNITED AC 2011; 112:e143-8. [DOI: 10.1016/j.tripleo.2011.06.029] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2011] [Revised: 06/18/2011] [Accepted: 06/21/2011] [Indexed: 11/21/2022]
|
346
|
Markvart M, Darvann TA, Larsen P, Dalstra M, Kreiborg S, Bjørndal L. Micro-CT analyses of apical enlargement and molar root canal complexity. Int Endod J 2011; 45:273-81. [DOI: 10.1111/j.1365-2591.2011.01972.x] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
347
|
Sahar-Helft S, Slutzky-Goldberg I, Moshonov J, Stabholtz A, Jacobovitz M, Tam A, Steinberg D. Synergistic Effect of Er:YAG Laser Irradiation in Combination with Chlorhexidine on the Viability of Enterococcus faecalis: An In Vitro Study. Photomed Laser Surg 2011; 29:753-8. [DOI: 10.1089/pho.2010.2981] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Sharonit Sahar-Helft
- Dept of Endodontics, Hebrew University Hadassah School of Dental Medicine, Jerusalem, Israel
| | - Iris Slutzky-Goldberg
- Dept of Endodontics, Hebrew University Hadassah School of Dental Medicine, Jerusalem, Israel
| | - Joshua Moshonov
- Dept of Endodontics, Hebrew University Hadassah School of Dental Medicine, Jerusalem, Israel
| | - Adam Stabholtz
- Dept of Endodontics, Hebrew University Hadassah School of Dental Medicine, Jerusalem, Israel
| | - Marcos Jacobovitz
- Dept of Endodontics, Hebrew University Hadassah School of Dental Medicine, Jerusalem, Israel
- Biofilm Research Laboratory, Institute of Dental Sciences, Hebrew University Hadassah School of Dental Medicine, Jerusalem, Israel
| | - Avshalom Tam
- Biofilm Research Laboratory, Institute of Dental Sciences, Hebrew University Hadassah School of Dental Medicine, Jerusalem, Israel
| | - Doron Steinberg
- Biofilm Research Laboratory, Institute of Dental Sciences, Hebrew University Hadassah School of Dental Medicine, Jerusalem, Israel
| |
Collapse
|
348
|
Gutmann JL, Gao Y. Alteration in the inherent metallic and surface properties of nickel-titanium root canal instruments to enhance performance, durability and safety: a focused review. Int Endod J 2011; 45:113-28. [PMID: 21902705 DOI: 10.1111/j.1365-2591.2011.01957.x] [Citation(s) in RCA: 139] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The expanded use of nickel-titanium (NiTi) rotary instruments in root canal procedures has led to the development of a wide variety of shapes, designs and applications. Root canal anatomy has not changed, however, and the same challenges exist in both initial treatment and the revision of unacceptable treatment. These challenges include application with high levels of achievement and low to no levels of adverse effects, such as instrument fracture, root canal wall ledging, dentine wall perforation and so forth. To that end, many manufacturers have been seeking ways to alter the presently available and wide range of root canal instrument designs, with a focus on altering the surface of the alloy or altering the alloy microstructure with post-machining or post-twisting heat treatment. This focused review will address the impact that these modifications have had on instrument flexibility, resistance to cyclic fatigue and cutting efficiency.
Collapse
Affiliation(s)
- J L Gutmann
- Baylor College of Dentistry, Texas A&M Health Science Center, Dallas, TX, USA.
| | | |
Collapse
|
349
|
You SY, Kim HC, Bae KS, Baek SH, Kum KY, Lee W. Shaping Ability of Reciprocating Motion in Curved Root Canals: A Comparative Study with Micro–Computed Tomography. J Endod 2011; 37:1296-300. [DOI: 10.1016/j.joen.2011.05.021] [Citation(s) in RCA: 85] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2011] [Revised: 05/14/2011] [Accepted: 05/17/2011] [Indexed: 10/18/2022]
|
350
|
Yang G, Yuan G, Yun X, Zhou X, Liu B, Wu H. Effects of two nickel-titanium instrument systems, Mtwo versus ProTaper universal, on root canal geometry assessed by micro-computed tomography. J Endod 2011; 37:1412-6. [PMID: 21924193 DOI: 10.1016/j.joen.2011.06.024] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2011] [Revised: 06/23/2011] [Accepted: 06/23/2011] [Indexed: 11/29/2022]
Abstract
INTRODUCTION The aim of this study was to compare the effects of Mtwo and ProTaper Universal (PTU) on root canal geometry three-dimensionally by using micro-computed tomography. METHODS A total of 20 canals were prepared with Mtwo or PTU system. Micro-computed tomography scanner was used to scan the specimens before and after instrumentation. Three-dimensional images were reconstructed. The parameters evaluated included canal surface area, volume, structure model index, thickness, straightening, canal transportation, and uninstrumented surface area. RESULTS Preparation significantly changed canal surface area, volume, structure model index, thickness, and canal curvature. There were no significant differences between instrument types concerning these parameters and uninstrumented surface area. The canals prepared with PTU showed larger values of transportation compared with those in Mtwo group at the apical third. CONCLUSIONS Both of the instrumentation systems produced canal preparations with adequate geometry. PTU produced larger transportation at apical third.
Collapse
Affiliation(s)
- Guobin Yang
- Key Laboratory for Oral Biomedical Engineering of Ministry of Education, School and Hospital of Stomatology, Wuhan University, Wuhan, China.
| | | | | | | | | | | |
Collapse
|