1
|
Hsiao CJ, Tung HC, Tien CL, Chang YW, Cheng CY. The influence of large-diameter multifocal contact lens on ocular surface, visual quality, and visual function for presbyopic adults with dry eye syndromes. Sci Rep 2023; 13:19444. [PMID: 37945680 PMCID: PMC10636056 DOI: 10.1038/s41598-023-46732-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Accepted: 11/04/2023] [Indexed: 11/12/2023] Open
Abstract
This study investigated the influence of large-diameter multifocal contact lenses on the ocular surface, visual quality, and visual function for presbyopic adults with dry eye syndromes. The study enrolled 40-55-year-old adults with presbyopia and dry eye syndromes (DES). The subjects were randomly assigned to three groups wearing different designs of contact lenses (Proclear, SMR, and Optimum) for 6-8 h a day for two weeks. Ocular surface health, tear quality, visual quality, and visual function were measured before and after lens wear. No significant difference was observed across all three groups for the amount of conjunctival redness, blink frequency (lens on), and stereopsis vision before and after wearing. Although there seemed to be a significant declining trend for corneal staining and limbal redness, non-invasive tear break-up time (TBUT), and lipid layer thickness while lens wear, the measured values were all within the normal range. Vice-versa after lens removal, results also showed significant improvement on lipid layer thickness, blink frequency (lens off), and contact TBUT. A significant improvement was observed in the modulation transfer function (MTF) of the total area ratio after wearing contact lenses. In contrast, the MTF of the high-order aberration area ratio resulting from lens wear was lower than that of the baseline measurement. There are also significant improvements observed for SMR and Optimum regarding near visual acuity, near point of accommodation, and the subjective questionnaire (OSDI and VBP) scores. Although it is difficult to avoid a specific negative impact on the ocular surface and tear film, visual function and visual quality can still be positively improved, especially shown on larger diameter and distance-center designed multifocal contact lenses.
Collapse
Affiliation(s)
- Ching-Jen Hsiao
- Department of Optometry, Chung Shan Medical University, Taichung, Taiwan
- Department of Ophthalmology, Chung Shan Medical University Hospital, Taichung, Taiwan
| | | | - Chuen-Lin Tien
- Department of Electrical Engineering, Feng Chia University, Taichung, Taiwan
| | - Yu-Wen Chang
- Department of Optometry, Chung Shan Medical University, Taichung, Taiwan
| | - Ching-Ying Cheng
- Department of Optometry, Chung Shan Medical University, Taichung, Taiwan.
- Department of Ophthalmology, Chung Shan Medical University Hospital, Taichung, Taiwan.
| |
Collapse
|
2
|
Singh S, Downie LE, Anderson AJ. Is critical flicker-fusion frequency a valid measure of visual fatigue? A post-hoc analysis of a double-masked randomised controlled trial. Ophthalmic Physiol Opt 2023; 43:176-182. [PMID: 36416367 PMCID: PMC10100408 DOI: 10.1111/opo.13073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 11/10/2022] [Accepted: 11/11/2022] [Indexed: 11/24/2022]
Abstract
PURPOSE Critical flicker-fusion frequency (CFF) has been used in clinical studies as a measure of visual fatigue. We examine the correlation between CFF and subjective reports of visual fatigue in a group of symptomatic computer users, to consider whether CFF may be used as a surrogate measure of visual fatigue symptoms. METHODS We analysed data from a previous randomised controlled trial. One hundred and twenty adults, diagnosed with computer vision syndrome, had CFF and visual fatigue symptoms quantified before and after a visually demanding 2-h computer task. Symptoms were assessed using a questionnaire with nine subcomponents that summed to a total score of 900. CFF was measured using a two-interval forced-choice method, with the flicker rate altered by a computer-controlled staircase procedure. For our primary analysis, we determined Spearman correlation coefficients between post-task symptom scores and CFF, and between change from baseline symptom scores and CFF. We also used a bootstrap procedure to consider whether symptom score subcomponents were significantly (Bonferroni-corrected) different from overall scores with regard to their correlations with CFF. RESULTS Although visual fatigue symptom scores altered significantly post-task (mean change: 92 units; 95% confidence interval [CI]: 11 to 122), CFF did not (mean change -0.7 Hz; 95% CI: -1.7 to 0.3). There was no significant correlation between overall symptom scores and CFF, either for the post-task (r = -0.13; 95% CI: -0.31 to 0.05) or the change from baseline (r = -0.18; 95% CI: -0.35 to 0.01) analysis. Subcomponents of the symptom questionnaire did not show a significant correlation with CFF, either for the post-task or the change from baseline analysis. CONCLUSIONS We find that CFF is not a useful surrogate for symptoms of visual fatigue, given its low correlation with scores on a visual fatigue symptom questionnaire.
Collapse
Affiliation(s)
- Sumeer Singh
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| | - Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| | - Andrew J Anderson
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
3
|
Nunes AF, Leitão MA, Nunes AS, Monteiro PL. Eye discomfort at close work in Portuguese university students: A comparative analysis between the pre-COVID and confinement period. Work 2023:WOR220172. [PMID: 36641726 DOI: 10.3233/wor-220172] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
Abstract
BACKGROUND Many individuals experience visual symptoms associated with near work. The level of discomfort appears to increase with the amount of digital screen use. OBJECTIVE To study the eye discomfort with near tasks in university students in the pre-COVID period and in the period of confinement due to the pandemic. METHODS Two independent samples of students, aged between 18 and 35 years, were used to assess symptomatic behaviour with the Convergence Insufficiency Symptom Survey (CISS) questionnaire. In the pre-COVID period the sample had 342 participants, 64.6% females and in the COVID period 322 students participated, 71.4% females. The study of differences was carried out by the Mann-Whitney U test. The interpretation of the statistical inference was performed for a significance level≤0.05. RESULTS There was an increase in the number of symptomatic cases in the COVID period without statistical evidence of differences in the frequency of symptoms reported in the two periods. The dimensions "somatic sensations" and "cognitive performance" were the typology of symptoms that most contributed to visual complaints with near vision. There was a significantly different symptomatic behaviour between genders in the period of confinement (p = 0.001), worsening in females and improving in males. CONCLUSION These findings suggest that females and males exposed to digital environments, over time, may exhibit different symptomatic behaviour. Our results suggest that boys adapt more quickly than girls. Factors that predispose to these changes, aetiology and potential intervention actions still need further study.
Collapse
Affiliation(s)
- Amélia Fernandes Nunes
- Health Sciences Research Centre (CICS-UBI), Covilhã,Portugal.,Clinical and Experimental Center for Vision Sciences (CCECV),U University of Beira Interior, Covilhã,Portugal.,UBIMedical, Covilhã,Portugal
| | - Mara Antunes Leitão
- Clinical and Experimental Center for Vision Sciences (CCECV),U University of Beira Interior, Covilhã,Portugal
| | | | - Pedro Lourenço Monteiro
- Health Sciences Research Centre (CICS-UBI), Covilhã,Portugal.,Clinical and Experimental Center for Vision Sciences (CCECV),U University of Beira Interior, Covilhã,Portugal.,UBIMedical, Covilhã,Portugal
| |
Collapse
|
4
|
Cantó-Sancho N, Porru S, Casati S, Ronda E, Seguí-Crespo M, Carta A. Prevalence and risk factors of computer vision syndrome-assessed in office workers by a validated questionnaire. PeerJ 2023; 11:e14937. [PMID: 36890870 PMCID: PMC9987297 DOI: 10.7717/peerj.14937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Accepted: 01/31/2023] [Indexed: 03/06/2023] Open
Abstract
Background Computer vision syndrome (CVS) is a common occupational health problem, but its clinical definition, prevalence and risk factors are not well defined. In general, non-validated diagnostic instruments have been used to assess its prevalence. For this reason, the aim of this study is to estimate the prevalence and potential risk factors for CVS using a validated questionnaire. Methods A cross-sectional study (n = 238) was carried out in Italian office workers using digital devices. All participants responded to an anamnesis, a digital exposure questionnaire, and the validated Italian version of the Computer Vision Syndrome Questionnaire. A battery of 3 ocular surface and tear ophthalmic tests (break-up time, BUT), Schirmer II and corneal staining) was performed. Results The mean age (±SD) was 45.55 (11.02) years, 64.3% were female. 71.4% wore glasses to work, whose design was monofocal (for distance) in 47.6%, monofocal (for near) in 26.5%, general progressive in 16.5% and occupational progressive in 8.8% of cases. 35.7% used digital devices >6 hours/day in the workplace. The prevalence of CVS was 67.2%. In the multivariate model, female sex (aOR: 3.17; 95% CI [1.75-5.73]), the use of digital devices >6 hours/day at workplace (aOR: 2.07; 95% CI [1.09-3.95]) and the use of optical correction at work (aOR: 2.69; 95% CI [1.43-5.08]) significantly increased the odds of CVS. Association was observed between presenting CVS and having abnormal BUT (χ2 = 0.017). Conclusions The prevalence of CVS in Italian office workers, especially among females, was high. Intensive use of digital devices at work (>6 hours/day) and the use of optical correction at work significantly increased the odds of CVS. There is an association between poor tear stability and CVS. Further research is needed on the influence of wearing optical correction on CVS. The use of a validated questionnaire in health surveillance of digital workers is strongly recommended.
Collapse
Affiliation(s)
- Natalia Cantó-Sancho
- Department of Optics, Pharmacology and Anatomy, University of Alicante, San Vicente del Raspeig, Alicante, Spain
| | - Stefano Porru
- Department of Diagnostics and Public Health, University of Verona, Verona, Véneto, Italy.,Mistral-Interuniversity Research Centre 'Integrated Models of Study for Health Protection and Prevention in Living and Working Environments', University of Brescia, Milano Bicocca and Verona, University of Verona, Verona, Véneto, Italy
| | - Stefano Casati
- Eye Clinic, Department of Neurosciences, Biomedicine and Movement Sciences, University of Verona, Verona, Véneto, Italy
| | - Elena Ronda
- Public Health Research Group, University of Alicante, San Vicente del Raspeig, Alicante, Spain.,Biomedical Research Networking Center for Epidemiology and Public Health (CIBERESP), Madrid, Madrid, Spain
| | - Mar Seguí-Crespo
- Department of Optics, Pharmacology and Anatomy, University of Alicante, San Vicente del Raspeig, Alicante, Spain.,Public Health Research Group, University of Alicante, San Vicente del Raspeig, Alicante, Spain
| | - Angela Carta
- Department of Diagnostics and Public Health, University of Verona, Verona, Véneto, Italy.,Mistral-Interuniversity Research Centre 'Integrated Models of Study for Health Protection and Prevention in Living and Working Environments', University of Brescia, Milano Bicocca and Verona, University of Verona, Verona, Véneto, Italy
| |
Collapse
|
5
|
Abusamak M, Jaber HM, Alrawashdeh HM. The Effect of Lockdown Due to the COVID-19 Pandemic on Digital Eye Strain Symptoms Among the General Population: A Cross-Sectional Survey. Front Public Health 2022; 10:895517. [PMID: 35812520 PMCID: PMC9256929 DOI: 10.3389/fpubh.2022.895517] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2022] [Accepted: 05/30/2022] [Indexed: 11/13/2022] Open
Abstract
Repetitive prolonged use of digital devices without regular breaks has detrimental effects on ocular health and quality of vision. Individuals with chronic eye problems and refractive errors are at higher risk of developing digital eye strain (DES). Correction of refractive errors, adopting healthy practices will reduce its risk. The survey examined the effect of prolonged lockdown on the development and increased severity of digital eye strain (DES) symptoms among the general population. An online survey was conducted in March 2020 on social media platforms in Jordan. Data from 1,460 responders were analyzed. About half of the respondents were between 30–49 years, 28.4% were retired, 21% had chronic systemic illness, and 23% reported chronic eye problems. A rise in the use of digital devices during lockdown was reported by 957 participants, with 33% of them used digital devices more than 4 h a day. The most common symptoms before and during lockdown were headache and neck / shoulder pain have the highest associations (X2 = 280.0, 271.3, df = 4, p < 0.001 respectively). Female gender, existence of chronic eye problems and systemic diseases, and duration of using digital devices were found to be statistically significant factors associated with increasing severity of eye symptoms during lockdown. Not taking enough regular breaks from digital devices showed significant association with blurred vision at distance and near (X2 = 13.03, 10.74, df = 4, P = 0.011, 0.03, respectively). People with chronic eye problems and increased time using devices during lockdown developed new eye complaints three times more than before the lockdown and males were two times more likely than females to have more severe eye symptoms.
Collapse
Affiliation(s)
- Mohammad Abusamak
- Department of Surgery, School of Medicine, Al-Balqa Applied University, Amman, Jordan
- Department of Public Health, Amman Eye Clinic, Amman, Jordan
- *Correspondence: Mohammad Abusamak
| | - Hatim M. Jaber
- Department of Community Medicine, School of Medicine, Al-Balqa Applied University, Amman, Jordan
| | - Hamzeh Mohammad Alrawashdeh
- Department of Community Medicine, School of Medicine, Al-Balqa Applied University, Amman, Jordan
- Ophthalmology Department, Sharif Eye Centers, Amman, Jordan
| |
Collapse
|
6
|
Magnavita N. Headache in the Workplace: Analysis of Factors Influencing Headaches in Terms of Productivity and Health. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19063712. [PMID: 35329399 PMCID: PMC8953285 DOI: 10.3390/ijerph19063712] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Revised: 03/16/2022] [Accepted: 03/18/2022] [Indexed: 12/15/2022]
Abstract
Headache is a very common condition that can have a significant impact on work. This study aimed to assess the prevalence of headaches and their impact on a sample of 1076 workers from 18 small companies operating in different sectors. The workers who volunteered to participate were asked to fill in the Headache Impact Test-6 (HIT-6) and answer questions designed to assess stressful and traumatic factors potentially associated with headaches. The volunteers subsequently underwent a medical examination and tests for diagnosing metabolic syndrome. Out of the 1044 workers who completed the questionnaire (participation rate = 97%), 509 (48.8%) reported suffering from headaches. In a multivariate logistic regression model, female gender, recent bereavement, intrusive leadership, and sleep problems were significantly associated with headaches. In univariate logistic regression models, headache intensity was associated with an increased risk of anxiety (OR 1.10; CI95% 1.09; 1.12) and depression (OR 1.09; CI95% 1.08; 1.11). Headache impact was also associated with the risk of metabolic syndrome (OR 1.02; CI95% 1.00, 1.04), obesity (OR 1.02, CI95% 1.01; 1.03), and reduced HDL cholesterol (OR 1.03; CI95% 1.01; 1.04). The impact of headache calls for intervention in the workplace not only to promote a prompt diagnosis of the different forms of headaches but also to improve work organization, leadership style, and the quality of sleep.
Collapse
Affiliation(s)
- Nicola Magnavita
- Postgraduate School of Occupational Health, Università Cattolica del Sacro Cuore, Largo F. Vito 1, 00168 Roma, Italy;
- Department of Science of Woman, Child and Public Health, A. Gemelli Foundation IRCCS, Largo A. Gemelli 8, 00168 Roma, Italy
| |
Collapse
|
7
|
Le Z, Antonov E, Mao Q, Petrov V, Wang Y, Wang W, Shevkolenko M, Dong W. Anti-Fatigue Glasses Based on Microprisms for Preventing Eyestrain. SENSORS 2022; 22:s22051933. [PMID: 35271080 PMCID: PMC8914742 DOI: 10.3390/s22051933] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Revised: 02/25/2022] [Accepted: 02/27/2022] [Indexed: 02/04/2023]
Abstract
Although microprisms have become an important medical means of strabismus treatment, related research concerning the design, fabrication, and testing of microprismatic glasses for preventing eyestrain has rarely been reported. In this study, the structure of microprismatic glasses for preventing eyestrain related to using electronic monitors, including computers and mobile phones, is introduced. A designing theory of anti-fatigue glasses with microprisms is developed. The fabrication technique and the process are described, and the performances of the fabricated microprisms are characterized. Finally, a compact testing system for the measurement of prismatic diopter is designed and constructed. This measuring system can be used not only for Fresnel microprisms, but also for other types of prisms. The measured results agree with our calculations. Although this study is focused on optimizing the objective prismatic diopter for anti-fatigue microprismatic glasses, 2.0–3.0 prismatic diopters (Δ) for each eye in the anti-fatigue glasses are suggested according to our experience on strabismus treatments. The clinical research for patients using the developed anti-fatigue glasses will be fully implemented in our further research to confirm the optimal subjective prismatic value.
Collapse
Affiliation(s)
- Zichun Le
- College of Science, Zhejiang University of Technology, Hangzhou 310023, China; (Z.L.); (Q.M.); (Y.W.); (W.W.)
| | - Evhen Antonov
- Institute for Information Recording, National Academy of Sciences of Ukraine, 03113 Kiev, Ukraine; (E.A.); (V.P.)
| | - Qiang Mao
- College of Science, Zhejiang University of Technology, Hangzhou 310023, China; (Z.L.); (Q.M.); (Y.W.); (W.W.)
| | - Viacheslav Petrov
- Institute for Information Recording, National Academy of Sciences of Ukraine, 03113 Kiev, Ukraine; (E.A.); (V.P.)
| | - Yuhui Wang
- College of Science, Zhejiang University of Technology, Hangzhou 310023, China; (Z.L.); (Q.M.); (Y.W.); (W.W.)
| | - Wei Wang
- College of Science, Zhejiang University of Technology, Hangzhou 310023, China; (Z.L.); (Q.M.); (Y.W.); (W.W.)
| | - Marina Shevkolenko
- Kiev City Clinical Ophthalmological Hospital “Eye Microsurgery Centre”, 03680 Kiev, Ukraine;
| | - Wen Dong
- College of Environment, Zhejiang University of Technology, Hangzhou 310014, China
- Correspondence: ; Tel.: +86-13306524039
| |
Collapse
|
8
|
Padhy D, Bharadwaj SR, Nayak S, Rath S, Das T. Does the Accuracy and Repeatability of Refractive Error Estimates Depend on the Measurement Principle of Autorefractors? Transl Vis Sci Technol 2021; 10:2. [PMID: 33505769 PMCID: PMC7794271 DOI: 10.1167/tvst.10.1.2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Accepted: 11/23/2020] [Indexed: 12/12/2022] Open
Abstract
Purpose The purpose of this study was to determine the accuracy and repeatability of refractive errors obtained using three autorefractors based on different measurement principles, vis-à-vis, gold-standard retinoscopy. Methodology Accuracy of noncycloplegic, sphero-cylindrical refractive error of 234 eyes was obtained using the rotary prism-based RM-8900 closed-field autorefractor, photorefraction based Spot vision screener, wavefront aberrometry based E-see, and streak retinoscopy by four different examiners, masked to the results of each other. Intersession repeatability of autorefractors was determined by repeat measurements in a subset of 40 subjects. Results Retinoscopy values of M, J0, and J45 power vectors for the cohort ranged from -10.2 to 8 D, -1.4 to 1.8 D, and -0.9 to 1.2 D, respectively. Across autorefractors, the interequipment bias of M and J0 power vectors were statistically insignificant (< ±0.5 D; P > 0.05) but the corresponding limits of agreement were ±2.5 and ±1 D, respectively, without any trend across instruments or the patient's age (P > 0.5). Repeatability of M and J0 power vectors were ±0.75 D and ±0.40 D, respectively, across autorefractors. The range of J45 power vector was too narrow for any meaningful analysis. Conclusions Refractive errors measured using autorefractors operating on different principles show minimal bias and good short-term repeatability but relatively large agreement limits, vis-à-vis, retinoscopy. Among them, the wavefront aberrometry based E-see autorefractor performs relatively better in all measurement parameters evaluated here. Translational Relevance Although autorefractor estimates of noncycloplegic refractive error appears independent of their measurement principle, their relatively poor agreement with gold-standard retinoscopy warrants caution while used for screening and quantification of refractive errors.
Collapse
Affiliation(s)
- Debananda Padhy
- Mithu Tulsi Chanrai campus, L V Prasad Eye Institute, Bhubaneswar, Odisha, India.,Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Banjara Hills, Hyderabad, Telangana, India
| | - Shrikant R Bharadwaj
- Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Banjara Hills, Hyderabad, Telangana, India
| | - Suryasmita Nayak
- Mithu Tulsi Chanrai campus, L V Prasad Eye Institute, Bhubaneswar, Odisha, India.,Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Banjara Hills, Hyderabad, Telangana, India
| | - Suryasnata Rath
- Ophthalmic Plastics, Orbit and Ocular Oncology Services, Mithu Tulsi Chanrai campus, L V Prasad Eye Institute, Bhubaneswar, Odisha, India
| | - Taraprasad Das
- Srimati Kanuri Santhamma Centre for Vitreoretinal Disease, L V Prasad Eye Institute, Banjara Hills, Hyderabad, Telangana, India
| |
Collapse
|
9
|
Lv X, Chen Y, Tan W, Yu Y, Zou H, Shao Y, Zan S, Tao J, Miao W. Functional Neuroanatomy of the Human Accommodation Response to an "E" Target Varying from -3 to -6 Diopters. Front Integr Neurosci 2020; 14:29. [PMID: 32508603 PMCID: PMC7253675 DOI: 10.3389/fnint.2020.00029] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Accepted: 04/24/2020] [Indexed: 12/16/2022] Open
Abstract
Background: We aimed to identify the functional brain networks involved in the regulation of visual accommodation by contrasting the cortical functional areas evoked by foveal fixation to an "E" target, which were subservient to the accommodation responses to a -3/-6 diopter stimulus. Methods: Neural activity was assessed in healthy volunteers by changes in blood oxygen level-dependent (BOLD) signals measured with functional magnetic resonance imaging (fMRI). Twenty-five right-handed subjects viewed the "E" target presented in a hierarchical block design. They participated in two monocular tasks: (i) sustained foveal fixation upon an "E" target on a white background at 33 cm (-3.03D accommodative demand); and (ii) sustained fixation through an attached -3D concave lens (-6D accommodative demand) in front of the fixated eye; each condition cycled through a standard alternating 30-s eye open/30-s eye closed design to provide the BOLD contrast. The total sustained period was 480 s. Results: The contrast between the -3D and the rest condition revealed activation in the occipital lobe (Lingual gyrus, Cuneus, Calcarine_L, and Calcarine_R); cerebellum (Cerebellum_Crus1_L and Cerebellum_6_L); precentral lobe (Precentral_R); frontal lobe (Frontal_Inf_Oper_R and Frontal_Mid_R); and cingulate cortex (Cingulum_Ant_L). With the -3D concave lenses (-6D accommodative demand) in front of the fixated eye, the voxel size and peak intensity of activation in the occipital lobe and cerebellum were greater than with the -3D accommodative demand; emergent activated brain areas included the parietal lobe (bilateral precuneus gyrus and right supramarginal gyrus); the precentral lobe and cingulate cortex failed to reach the threshold in the -6D vs. rest contrast. In the -3D and -6D contrast comparison, the frontal lobe (Frontal_Sup_Medial_L) and parietal lobe (Precuneus_L and Precuneus_R) passed the significance threshold of cluster-level family-wise error (FWE) correction. The mean activation in the -3D and -6D contrast revealed an incremental summation of the activations than that found in the previous -3D vs. rest and -6D vs. rest comparisons. Conclusions: Neural circuits were selectively activated during the -3D/-6D accommodative response to blur cues. Cognitive-perceptual processing is involved in signal regulation of ocular accommodative functions.
Collapse
Affiliation(s)
- Xiaoli Lv
- Department of Ophthalmology, Shuguang Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, China.,Department of Ophthalmology, The Second Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, China
| | - Yilei Chen
- Department of Radiology, Shuguang Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Wenli Tan
- Department of Radiology, Shuguang Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Ying Yu
- Department of Ophthalmology, Shuguang Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Hong Zou
- Department of Ophthalmology, Shuguang Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Yu Shao
- Department of Ophthalmology, The Second Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, China
| | - Songhua Zan
- Department of Radiology, Shuguang Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Jinhua Tao
- Department of Ophthalmology, Shuguang Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Wanhong Miao
- Department of Ophthalmology, Shuguang Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| |
Collapse
|
10
|
Heus P, Verbeek JH, Tikka C. Optical correction of refractive error for preventing and treating eye symptoms in computer users. Cochrane Database Syst Rev 2018; 4:CD009877. [PMID: 29633784 PMCID: PMC6494484 DOI: 10.1002/14651858.cd009877.pub2] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Computer users frequently complain about problems with seeing and functioning of the eyes. Asthenopia is a term generally used to describe symptoms related to (prolonged) use of the eyes like ocular fatigue, headache, pain or aching around the eyes, and burning and itchiness of the eyelids. The prevalence of asthenopia during or after work on a computer ranges from 46.3% to 68.5%. Uncorrected or under-corrected refractive error can contribute to the development of asthenopia. A refractive error is an error in the focusing of light by the eye and can lead to reduced visual acuity. There are various possibilities for optical correction of refractive errors including eyeglasses, contact lenses and refractive surgery. OBJECTIVES To examine the evidence on the effectiveness, safety and applicability of optical correction of refractive error for reducing and preventing eye symptoms in computer users. SEARCH METHODS We searched the Cochrane Central Register of Controlled Trials (CENTRAL); PubMed; Embase; Web of Science; and OSH update, all to 20 December 2017. Additionally, we searched trial registries and checked references of included studies. SELECTION CRITERIA We included randomised controlled trials (RCTs) and quasi-randomised trials of interventions evaluating optical correction for computer workers with refractive error for preventing or treating asthenopia and their effect on health related quality of life. DATA COLLECTION AND ANALYSIS Two authors independently assessed study eligibility and risk of bias, and extracted data. Where appropriate, we combined studies in a meta-analysis. MAIN RESULTS We included eight studies with 381 participants. Three were parallel group RCTs, three were cross-over RCTs and two were quasi-randomised cross-over trials. All studies evaluated eyeglasses, there were no studies that evaluated contact lenses or surgery. Seven studies evaluated computer glasses with at least one focal area for the distance of the computer screen with or without additional focal areas in presbyopic persons. Six studies compared computer glasses to other types of glasses; and one study compared them to an ergonomic workplace assessment. The eighth study compared optimal correction of refractive error with the actual spectacle correction in use. Two studies evaluated computer glasses in persons with asthenopia but for the others the glasses were offered to all workers regardless of symptoms. The risk of bias was unclear in five, high in two and low in one study. Asthenopia was measured as eyestrain or a summary score of symptoms but there were no studies on health-related quality of life. Adverse events were measured as headache, nausea or dizziness. Median asthenopia scores at baseline were about 30% of the maximum possible score.Progressive computer glasses versus monofocal glassesOne study found no considerable difference in asthenopia between various progressive computer glasses and monofocal computer glasses after one-year follow-up (mean difference (MD) change scores 0.23, 95% confidence interval (CI) -5.0 to 5.4 on a 100 mm VAS scale, low quality evidence). For headache the results were in favour of progressive glasses.Progressive computer glasses with an intermediate focus in the upper part of the glasses versus other glassesIn two studies progressive computer glasses with intermediate focus led to a small decrease in asthenopia symptoms (SMD -0.49, 95% CI -0.75 to -0.23, low-quality evidence) but not in headache score in the short-term compared to general purpose progressive glasses. There were similar small decreases in dizziness. At medium term follow-up, in one study the effect size was not statistically significant (SMD -0.64, 95% CI -1.40 to 0.12). The study did not assess adverse events.Another study found no considerable difference in asthenopia between progressive computer glasses and monofocal computer glasses after one-year follow-up (MD change scores 1.44, 95% CI -6.95 to 9.83 on a 100 mm VAS scale, very low quality evidence). For headache the results were inconsistent.Progressive computer glasses with far-distance focus in the upper part of the glasses versus other glassesOne study found no considerable difference in number of persons with asthenopia between progressive computer glasses with far-distance focus and bifocal computer glasses after four weeks' follow-up (OR 1.00, 95% CI 0.40 to 2.50, very low quality evidence). The number of persons with headache, nausea and dizziness was also not different between groups.Another study found no considerable difference in asthenopia between progressive computer glasses with far-distance focus and monofocal computer glasses after one-year follow-up (MD change scores -1.79, 95% CI -11.60 to 8.02 on a 100 mm VAS scale, very low quality evidence). The effects on headaches were inconsistent.One study found no difference between progressive far-distance focus computer glasses and trifocal glasses in effect on eyestrain severity (MD -0.50, 95% CI -1.07 to 0.07, very low quality evidence) or on eyestrain frequency (MD -0.75, 95% CI -1.61 to 0.11, very low quality evidence).Progressive computer glasses versus ergonomic assessment with habitual (computer) glassesOne study found that computer glasses optimised for individual needs reduced asthenopia sum score more than an ergonomic assessment and habitual (computer) glasses (MD -8.9, 95% CI -16.47 to -1.33, scale 0 to 140, very low quality evidence) but there was no effect on the frequency of eyestrain (OR 1.08, 95% CI 0.38 to 3.11, very low quality evidence).We rated the quality of the evidence as low or very low due to risk of bias in the included studies, inconsistency in the results and imprecision. AUTHORS' CONCLUSIONS There is low to very low quality evidence that providing computer users with progressive computer glasses does not lead to a considerable decrease in problems with the eyes or headaches compared to other computer glasses. Progressive computer glasses might be slightly better than progressive glasses for daily use in the short term but not in the intermediate term and there is no data on long-term follow-up. The quality of the evidence is low or very low and therefore we are uncertain about this conclusion. Larger studies with several hundreds of participants are needed with proper randomisation, validated outcome measurement methods, and longer follow-up of at least one year to improve the quality of the evidence.
Collapse
Affiliation(s)
- Pauline Heus
- Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht UniversityCochrane NetherlandsRoom Str. 6.131PO Box 85500UtrechtNetherlands3508 GA
| | - Jos H Verbeek
- Finnish Institute of Occupational HealthCochrane Work Review GroupTYÖTERVEYSLAITOSFinlandFI‐70032
| | - Christina Tikka
- Finnish Institute of Occupational HealthCochrane Work Review GroupTYÖTERVEYSLAITOSFinlandFI‐70032
| | | |
Collapse
|