1
|
Kim SH, Basir A, Avila R, Lim J, Hong SW, Choe G, Shin JH, Hwang JH, Park SY, Joo J, Lee C, Choi J, Lee B, Choi KS, Jung S, Kim TI, Yoo H, Jung YH. Strain-invariant stretchable radio-frequency electronics. Nature 2024; 629:1047-1054. [PMID: 38778108 DOI: 10.1038/s41586-024-07383-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Accepted: 04/04/2024] [Indexed: 05/25/2024]
Abstract
Wireless modules that provide telecommunications and power-harvesting capabilities enabled by radio-frequency (RF) electronics are vital components of skin-interfaced stretchable electronics1-7. However, recent studies on stretchable RF components have demonstrated that substantial changes in electrical properties, such as a shift in the antenna resonance frequency, occur even under relatively low elastic strains8-15. Such changes lead directly to greatly reduced wireless signal strength or power-transfer efficiency in stretchable systems, particularly in physically dynamic environments such as the surface of the skin. Here we present strain-invariant stretchable RF electronics capable of completely maintaining the original RF properties under various elastic strains using a 'dielectro-elastic' material as the substrate. Dielectro-elastic materials have physically tunable dielectric properties that effectively avert frequency shifts arising in interfacing RF electronics. Compared with conventional stretchable substrate materials, our material has superior electrical, mechanical and thermal properties that are suitable for high-performance stretchable RF electronics. In this paper, we describe the materials, fabrication and design strategies that serve as the foundation for enabling the strain-invariant behaviour of key RF components based on experimental and computational studies. Finally, we present a set of skin-interfaced wireless healthcare monitors based on strain-invariant stretchable RF electronics with a wireless operational distance of up to 30 m under strain.
Collapse
Affiliation(s)
- Sun Hong Kim
- Department of Electronic Engineering, Hanyang University, Seoul, Republic of Korea
| | - Abdul Basir
- Department of Electronic Engineering, Hanyang University, Seoul, Republic of Korea
| | - Raudel Avila
- Department of Mechanical Engineering, Rice University, Houston, TX, USA
| | - Jaeman Lim
- Department of Electronic Engineering, Hanyang University, Seoul, Republic of Korea
| | - Seong Woo Hong
- Department of Electronic Engineering, Hanyang University, Seoul, Republic of Korea
| | - Geonoh Choe
- Department of Electronic Engineering, Hanyang University, Seoul, Republic of Korea
| | - Joo Hwan Shin
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, Republic of Korea
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University (SKKU), Suwon, Republic of Korea
| | - Jin Hee Hwang
- Department of Electronic Engineering, Hanyang University, Seoul, Republic of Korea
| | - Sun Young Park
- Department of Electronic Engineering, Hanyang University, Seoul, Republic of Korea
| | - Jiho Joo
- Superintelligence Creative Research Laboratory, Electronics and Telecommunications Research Institute, Daejeon, Republic of Korea
| | - Chanmi Lee
- Superintelligence Creative Research Laboratory, Electronics and Telecommunications Research Institute, Daejeon, Republic of Korea
| | - Jaehoon Choi
- Department of Electronic Engineering, Hanyang University, Seoul, Republic of Korea
| | - Byunghun Lee
- Department of Electronic Engineering, Hanyang University, Seoul, Republic of Korea
- Department of Biomedical Engineering, Hanyang University, Seoul, Republic of Korea
| | - Kwang-Seong Choi
- Superintelligence Creative Research Laboratory, Electronics and Telecommunications Research Institute, Daejeon, Republic of Korea
| | - Sungmook Jung
- Division of Advanced Materials, Korea Research Institute of Chemical Technology (KRICT), Daejeon, Republic of Korea
| | - Tae-Il Kim
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, Republic of Korea
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University (SKKU), Suwon, Republic of Korea
| | - Hyoungsuk Yoo
- Department of Electronic Engineering, Hanyang University, Seoul, Republic of Korea.
- Department of Biomedical Engineering, Hanyang University, Seoul, Republic of Korea.
| | - Yei Hwan Jung
- Department of Electronic Engineering, Hanyang University, Seoul, Republic of Korea.
- Institute of Nano Science and Technology, Hanyang University, Seoul, Republic of Korea.
| |
Collapse
|
2
|
Kang K, Ye S, Jeong C, Jeong J, Ye YS, Jeong JY, Kim YJ, Lim S, Kim TH, Kim KY, Kim JU, Kim GI, Chun DH, Kim K, Park J, Hong JH, Park B, Kim K, Jung S, Baek K, Cho D, Yoo J, Lee K, Cheng H, Min BW, Kim HJ, Jeon H, Yi H, Kim TI, Yu KJ, Jung Y. Bionic artificial skin with a fully implantable wireless tactile sensory system for wound healing and restoring skin tactile function. Nat Commun 2024; 15:10. [PMID: 38169465 PMCID: PMC10762199 DOI: 10.1038/s41467-023-44064-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Accepted: 11/29/2023] [Indexed: 01/05/2024] Open
Abstract
Tactile function is essential for human life as it enables us to recognize texture and respond to external stimuli, including potential threats with sharp objects that may result in punctures or lacerations. Severe skin damage caused by severe burns, skin cancer, chemical accidents, and industrial accidents damage the structure of the skin tissue as well as the nerve system, resulting in permanent tactile sensory dysfunction, which significantly impacts an individual's daily life. Here, we introduce a fully-implantable wireless powered tactile sensory system embedded artificial skin (WTSA), with stable operation, to restore permanently damaged tactile function and promote wound healing for regenerating severely damaged skin. The fabricated WTSA facilitates (i) replacement of severely damaged tactile sensory with broad biocompatibility, (ii) promoting of skin wound healing and regeneration through collagen and fibrin-based artificial skin (CFAS), and (iii) minimization of foreign body reaction via hydrogel coating on neural interface electrodes. Furthermore, the WTSA shows a stable operation as a sensory system as evidenced by the quantitative analysis of leg movement angle and electromyogram (EMG) signals in response to varying intensities of applied pressures.
Collapse
Affiliation(s)
- Kyowon Kang
- Department of Electrical and Electronic Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Seongryeol Ye
- Center for Biomaterials, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, Korea
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Korea
| | - Chanho Jeong
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Jinmo Jeong
- Post-Silicon Semiconductor Institute, Korea Institute of Science and Technology, Seoul, 02792, Republic of Korea
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, 78712, USA
| | - Yeong-Sinn Ye
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Jin-Young Jeong
- Post-Silicon Semiconductor Institute, Korea Institute of Science and Technology, Seoul, 02792, Republic of Korea
| | - Yu-Jin Kim
- Center for Biomaterials, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, Korea
| | - Selin Lim
- Department of Electrical and Electronic Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
- School of Electrical and Electronic Engineering, YU-KIST Institute, Yonsei University, Seoul, Republic of Korea
| | - Tae Hee Kim
- Center for Biomaterials, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, Korea
- Department of Fusion Research and Collaboration, Biomedical Research Institute, Seoul National University Hospital, Seoul, 03080, Republic of Korea
| | - Kyung Yeun Kim
- Biomaterials Research Center, Biomedical Research Division, Korea Institute of Science and Technology, Seoul, 02792, Republic of Korea
- Department of Mechanical Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826, Republic of Korea
| | - Jong Uk Kim
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA
| | - Gwan In Kim
- Department of Electrical and Electronic Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
- Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA
| | - Do Hoon Chun
- Department of Electrical and Electronic Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Kiho Kim
- Department of Electrical and Electronic Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Jaejin Park
- Department of Electrical and Electronic Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Jung-Hoon Hong
- Department of Electrical and Electronic Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Byeonghak Park
- Department of Chemical Engineering, Stanford University, Stanford, CA, 94305, USA
| | - Kyubeen Kim
- Department of Electrical and Electronic Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Sujin Jung
- Department of Electrical and Electronic Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Kyeongrim Baek
- Department of Electrical and Electronic Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Dongjun Cho
- Department of Electrical and Electronic Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Jin Yoo
- Center for Biomaterials, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, Korea
| | - Kangwon Lee
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Korea
- Research Institute for Convergence Science, Seoul National University, Seoul, 08826, Republic of Korea
| | - Huanyu Cheng
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, 16802, USA
| | - Byung-Wook Min
- Department of Electrical and Electronic Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Hyun Jae Kim
- Department of Electrical and Electronic Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Hojeong Jeon
- Biomaterials Research Center, Biomedical Research Division, Korea Institute of Science and Technology, Seoul, 02792, Republic of Korea
- KU-KIST Graduate School of Converging Science and Technology, Korea University, Seoul, 02841, Republic of Korea
| | - Hyunjung Yi
- Post-Silicon Semiconductor Institute, Korea Institute of Science and Technology, Seoul, 02792, Republic of Korea.
- Department of Materials Science and Engineering, YU-KIST Institute, Yonsei University, Seoul, 03722, Republic of Korea.
| | - Tae-Il Kim
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea.
| | - Ki Jun Yu
- Department of Electrical and Electronic Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea.
- School of Electrical and Electronic Engineering, YU-KIST Institute, Yonsei University, Seoul, Republic of Korea.
| | - Youngmee Jung
- Center for Biomaterials, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, Korea.
- School of Electrical and Electronic Engineering, YU-KIST Institute, Yonsei University, Seoul, Republic of Korea.
| |
Collapse
|
3
|
Yuan J, Zhang Y, Wei C, Zhu R. A Fully Self-Powered Wearable Leg Movement Sensing System for Human Health Monitoring. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2303114. [PMID: 37590377 PMCID: PMC10582417 DOI: 10.1002/advs.202303114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 07/18/2023] [Indexed: 08/19/2023]
Abstract
Energy-autonomous wearable human activity monitoring is imperative for daily healthcare, benefiting from long-term sustainable uses. Herein, a fully self-powered wearable system, enabling real-time monitoring and assessments of human multimodal health parameters including knee joint movement, metabolic energy, locomotion speed, and skin temperature, which are fully self-powered by highly-efficient flexible thermoelectric generators (f-TEGs) is proposed and developed. The wearable system is composed of f-TEGs, fabric strain sensors, ultra-low-power edge computing, and Bluetooth. The f-TEGs worn on the leg not only harvest energy from body heat and supply power sustainably for the whole monitoring system, but also serve as zero-power motion sensors to detect limb movement and skin temperature. The fabric strain sensor made by printing PEDOT: PSS on pre-stretched nylon fiber-wrapped rubber band enables high-fidelity and ultralow-power measurements on highly-dynamic knee movements. Edge computing is elaborately designed to estimate multimodal health parameters including time-varying metabolic energy in real-time, which are wirelessly transmitted via Bluetooth. The whole monitoring system is operated automatically and intelligently, works sustainably in both static and dynamic states, and is fully self-powered by the f-TEGs.
Collapse
Affiliation(s)
- Jinfeng Yuan
- State Key Laboratory of Precision Measurement Technology and InstrumentsDepartment of Precision InstrumentTsinghua UniversityBeijing100084China
| | - Yuzhong Zhang
- State Key Laboratory of Precision Measurement Technology and InstrumentsDepartment of Precision InstrumentTsinghua UniversityBeijing100084China
| | - Caise Wei
- State Key Laboratory of Precision Measurement Technology and InstrumentsDepartment of Precision InstrumentTsinghua UniversityBeijing100084China
| | - Rong Zhu
- State Key Laboratory of Precision Measurement Technology and InstrumentsDepartment of Precision InstrumentTsinghua UniversityBeijing100084China
| |
Collapse
|
4
|
Choi YW, Yoo SS, Lee JH, Moon MW, Yoo PJ. Graphite/SnSe hybrid-embedded monolithic foams with hierarchical and bimodal pores for high performance solar desalination membranes with spontaneous salt rejection. Sep Purif Technol 2022. [DOI: 10.1016/j.seppur.2022.122166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
5
|
Hu J, Ren P, Zhu G, Yang J, Li Y, Zong Z, Sun Z. Serpentine-inspired Strain Sensor with Predictable Cracks for Remote Bio-Mechanical Signal Monitoring. Macromol Rapid Commun 2022; 43:e2200372. [PMID: 35759398 DOI: 10.1002/marc.202200372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Revised: 06/11/2022] [Indexed: 11/08/2022]
Abstract
The flexible strain sensors have attracted intense interests due to their application as intelligent wearable electronic devices. However, it is still a huge challenge to achieve the flexible sensor with simultaneous high sensitivity, excellent durability and wide sensing region. In this work, a crack-based strain sensor with paired-serpentine conductive network is fabricated onto flexible film by screen printing. The innovative conductive network exhibits a controlled crack morphology during stretching, which endows the prepared sensor with outstanding sensing characteristics, including the high sensitivity (gauge factor up to 2391.5), wide detection (rang up to 132%), low strain detection limit, fast response time (about 40 ms), as well as excellent durability (more than 2000 stretching/releasing cycles). Benefiting from these excellent performances, full-range human body motions including subtle physiological signals and large motions are accurately detected by the prepared sensor. Besides, wearable electronic equipment integrated with wireless transmitter and the prepared strain sensor shows great potential for remote motion monitoring and intelligent mobile diagnosis for humans. This work provides an effective strategy for the fabrication of the novel strain sensors with highly comprehensive performance. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Jie Hu
- The Faculty of Printing, Packaging Engineering and Digital Media Technology, Xi'an University of Technology, Xi'an Shaanxi, 710048, People's Republic of China
| | - Penggang Ren
- The Faculty of Printing, Packaging Engineering and Digital Media Technology, Xi'an University of Technology, Xi'an Shaanxi, 710048, People's Republic of China.,College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu Sichuan, 610065, People's Republic of China
| | - Guanjun Zhu
- School of Materials Science and Engineering, Xi'an University of Technology, Xi'an Shaanxi, 710048, People's Republic of China
| | - Junjun Yang
- The Faculty of Printing, Packaging Engineering and Digital Media Technology, Xi'an University of Technology, Xi'an Shaanxi, 710048, People's Republic of China
| | - Yanhao Li
- The Faculty of Printing, Packaging Engineering and Digital Media Technology, Xi'an University of Technology, Xi'an Shaanxi, 710048, People's Republic of China
| | - Ze Zong
- The Faculty of Printing, Packaging Engineering and Digital Media Technology, Xi'an University of Technology, Xi'an Shaanxi, 710048, People's Republic of China
| | - Zhenfeng Sun
- The Faculty of Printing, Packaging Engineering and Digital Media Technology, Xi'an University of Technology, Xi'an Shaanxi, 710048, People's Republic of China
| |
Collapse
|
6
|
Abstract
Textile-based sensors in the form of a wearable computing device that can be attached to or worn on the human body not only can transmit information but also can be used as a smart sensing device to access the mobile internet. These sensors represent a potential platform for the next generation of human-computer interfaces. The continuous emergence of new conductive materials is one of the driving forces for the development of textile sensors. Recently, a two-dimensional (2D) MXene material with excellent performance has received extensive attention due to its high conductivity, processability, and mechanical stability. In this paper, the synthesis of MXene materials, the fabrication of conductive textiles, the structural design of textile sensors, and the application of MXene-based textile sensors in the wearable field are reviewed. Furthermore, from the perspective of MXene preparation, wearability, stability, and evaluation standards, the difficulties and challenges of MXene-based textile sensors in the field of wearable applications are summarized and prospected. This review attempts to strengthen the connection between wearable smart textiles and MXene materials and promote the rapid development of wearable MXene-based textile sensors.
Collapse
Affiliation(s)
- Chun Jin
- Human-Computer Interaction Design Lab, School of System Design and Intelligent Manufacturing, Southern University of Science and Technology, Shenzhen, 518055, People’s Republic of China
- Harbin Institute of Technology, Harbin, 150080, People’s Republic of China
| | - Ziqian Bai
- Human-Computer Interaction Design Lab, School of System Design and Intelligent Manufacturing, Southern University of Science and Technology, Shenzhen, 518055, People’s Republic of China
| |
Collapse
|
7
|
Zhang Z, Su R, Han F, Zheng Z, Liu Y, Zhou X, Li Q, Zhai X, Wu J, Pan X, Pan H, Guo P, Li Z, Liu Z, Zhao X. A soft intelligent dressing with pH and temperature sensors for early detection of wound infection. RSC Adv 2022; 12:3243-3252. [PMID: 35425400 PMCID: PMC8979260 DOI: 10.1039/d1ra08375a] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Accepted: 01/16/2022] [Indexed: 12/28/2022] Open
Abstract
Wound infection is a common clinical problem. Traditional detection methods can not provide infection early warning information in time. With the development of flexible electronics, flexible wearable devices have been widely used in the field of intelligent monitoring. Here, we describe the development of a soft wound infection monitoring system with pH sensors and temperature sensors. The measurement range of pH was 4–10, the fitting accuracy was 99.8%, and the response time was less than 6 s. The temperature sensor array showed good accuracy and short response times in the range of 30 °C to 40 °C. A series of in vitro tests and the use of a rat model of Staphylococcus aureus infection confirmed that this flexible detection system can monitor the pH and temperature changes occurring in the early stage of infection, which provides an effective reference for clinical application. A soft intelligent dressing can monitor the changes of pH and temperature in the early stage of infection, which provides a possibility for wearable wound real-time monitoring.![]()
Collapse
Affiliation(s)
- Zhiyang Zhang
- School of Materials Science and Engineering, Tianjin Key Laboratory of Composite and Functional Materials, Tianjin University, Tianjin 300350, PR China
- Research Center for Human Tissue and Organs Degeneration, Institute of Biomedicine and Biotechnology, Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences, Shenzhen 518055, PR China
| | - Rui Su
- Research Center for Human Tissue and Organs Degeneration, Institute of Biomedicine and Biotechnology, Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences, Shenzhen 518055, PR China
- Institute of Materials for Energy and Environment, State Key Laboratory of Bio-fibers and Eco-textiles, School of Materials Science and Engineering, Qingdao University, Qingdao 266071, PR China
| | - Fei Han
- Neural Engineering Center, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, PR China
| | - Zhiqiang Zheng
- Research Center for Human Tissue and Organs Degeneration, Institute of Biomedicine and Biotechnology, Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences, Shenzhen 518055, PR China
| | - Yuan Liu
- Research Center for Human Tissue and Organs Degeneration, Institute of Biomedicine and Biotechnology, Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences, Shenzhen 518055, PR China
| | - Xiaomeng Zhou
- Neural Engineering Center, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, PR China
| | - Qingsong Li
- Neural Engineering Center, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, PR China
| | - Xinyun Zhai
- Center for Rare Earth and Inorganic Functional Materials, School of Materials Science and Engineering, National Institute for Advanced Materials, Nankai University, Tianjin 300350, PR China
| | - Jun Wu
- Shenzhen Key Laboratory for Innovative Technology in Orthopaedic Trauma, The University of Hong Kong-Shenzhen Hospital, Shenzhen 518053, PR China
| | - Xiaohua Pan
- Southern Medical University, Shenzhen Bao'an People's Hospital, Dept Orthoped & Traumatol, Shenzhen 518101, PR China
| | - Haobo Pan
- Research Center for Human Tissue and Organs Degeneration, Institute of Biomedicine and Biotechnology, Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences, Shenzhen 518055, PR China
| | - Peizhi Guo
- Institute of Materials for Energy and Environment, State Key Laboratory of Bio-fibers and Eco-textiles, School of Materials Science and Engineering, Qingdao University, Qingdao 266071, PR China
| | - Zhaoyang Li
- School of Materials Science and Engineering, Tianjin Key Laboratory of Composite and Functional Materials, Tianjin University, Tianjin 300350, PR China
| | - Zhiyuan Liu
- Neural Engineering Center, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, PR China
| | - Xiaoli Zhao
- Research Center for Human Tissue and Organs Degeneration, Institute of Biomedicine and Biotechnology, Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences, Shenzhen 518055, PR China
| |
Collapse
|
8
|
Cho KW, Sunwoo SH, Hong YJ, Koo JH, Kim JH, Baik S, Hyeon T, Kim DH. Soft Bioelectronics Based on Nanomaterials. Chem Rev 2021; 122:5068-5143. [PMID: 34962131 DOI: 10.1021/acs.chemrev.1c00531] [Citation(s) in RCA: 46] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Recent advances in nanostructured materials and unconventional device designs have transformed the bioelectronics from a rigid and bulky form into a soft and ultrathin form and brought enormous advantages to the bioelectronics. For example, mechanical deformability of the soft bioelectronics and thus its conformal contact onto soft curved organs such as brain, heart, and skin have allowed researchers to measure high-quality biosignals, deliver real-time feedback treatments, and lower long-term side-effects in vivo. Here, we review various materials, fabrication methods, and device strategies for flexible and stretchable electronics, especially focusing on soft biointegrated electronics using nanomaterials and their composites. First, we summarize top-down material processing and bottom-up synthesis methods of various nanomaterials. Next, we discuss state-of-the-art technologies for intrinsically stretchable nanocomposites composed of nanostructured materials incorporated in elastomers or hydrogels. We also briefly discuss unconventional device design strategies for soft bioelectronics. Then individual device components for soft bioelectronics, such as biosensing, data storage, display, therapeutic stimulation, and power supply devices, are introduced. Afterward, representative application examples of the soft bioelectronics are described. A brief summary with a discussion on remaining challenges concludes the review.
Collapse
Affiliation(s)
- Kyoung Won Cho
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea.,Interdisciplinary Program for Bioengineering, Seoul National University, Seoul 08826, Republic of Korea
| | - Sung-Hyuk Sunwoo
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea.,School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, Seoul 08826, Republic of Korea
| | - Yongseok Joseph Hong
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea.,School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, Seoul 08826, Republic of Korea
| | - Ja Hoon Koo
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea
| | - Jeong Hyun Kim
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea
| | - Seungmin Baik
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea.,School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, Seoul 08826, Republic of Korea
| | - Taeghwan Hyeon
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea.,Interdisciplinary Program for Bioengineering, Seoul National University, Seoul 08826, Republic of Korea.,School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, Seoul 08826, Republic of Korea
| | - Dae-Hyeong Kim
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea.,Interdisciplinary Program for Bioengineering, Seoul National University, Seoul 08826, Republic of Korea.,School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, Seoul 08826, Republic of Korea.,Department of Materials Science and Engineering, Seoul National University, Seoul 08826, Republic of Korea
| |
Collapse
|
9
|
Ramírez J, Polat B, Lipomi DJ. Metallic Nanoislands on Graphene for Biomechanical Sensing. ACS OMEGA 2020; 5:15763-15770. [PMID: 32656394 PMCID: PMC7345399 DOI: 10.1021/acsomega.0c01967] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 06/09/2020] [Indexed: 06/11/2023]
Abstract
This minireview describes a nanomaterial-based multimodal sensor for performing biomechanical measurements. The sensor consists of ultrathin metallic films on single-layer graphene. This composite material exhibits physical properties that neither material possesses alone. For example, the metal, deposited by evaporation at low (≤10 nm) nominal thicknesses, renders the film highly sensitive to mechanical stimuli, which can be detected using electrical (i.e., resistance) and optical (i.e., plasmonic) modalities. The electrical modality, in particular, is capable of resolving deformations as small as 0.0001% engineering strain, or 1 ppm. The electrical and optical responses of the composite films can be tailored by controlling the morphology of the metallic film. This morphology (granular or island-like when deposited onto the graphene) can be tuned using the conditions of deposition, the identity of the substrate beneath the graphene, or even the replacement of the graphene for hexagonal boron nitride (hBN). This material responds to forces produced by a range of physiological structures, from the contractions of heart muscle cells, to the beating of the heart through the skin, to stretching of the skin due to the expansion of the lungs and movement of limbs. Here, we provide an update on recent applications of this material in fields ranging from cardiovascular medicine (by measuring the contractions of 2D monolayers of cardiomyocytes), regenerative medicine (optical measurements of the forces produced by myoblasts), speech pathology and physical therapy (measuring swallowing function in head and neck cancer survivors), lab-on-a-chip devices (using deformation of sidewalls of microfluidic channels to detect transiting objects), and sleep medicine (measuring pulse and respiration with a wearable, unobtrusive device). We also discuss the mechanisms by which these films detect strain.
Collapse
Affiliation(s)
- Julian Ramírez
- Department of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, Mail Code 0448, La Jolla, California 92093-0448, United States
| | - Beril Polat
- Department of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, Mail Code 0448, La Jolla, California 92093-0448, United States
| | - Darren J. Lipomi
- Department of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, Mail Code 0448, La Jolla, California 92093-0448, United States
| |
Collapse
|
10
|
Joo H, Jung D, Sunwoo SH, Koo JH, Kim DH. Material Design and Fabrication Strategies for Stretchable Metallic Nanocomposites. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e1906270. [PMID: 32022440 DOI: 10.1002/smll.201906270] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 12/20/2019] [Indexed: 06/10/2023]
Abstract
Stretchable conductive nanocomposites fabricated by integrating metallic nanomaterials with elastomers have become a vital component of human-friendly electronics, such as wearable and implantable devices, due to their unconventional electrical and mechanical characteristics. Understanding the detailed material design and fabrication strategies to improve the conductivity and stretchability of the nanocomposites is therefore important. This Review discusses the recent technological advances toward high performance stretchable metallic nanocomposites. First, the effect of the filler material design on the conductivity is briefly discussed, followed by various nanocomposite fabrication techniques to achieve high conductivity. Methods for maintaining the initial conductivity over a long period of time are also summarized. Then, strategies on controlled percolation of nanomaterials are highlighted, followed by a discussion regarding the effects of the morphology of the nanocomposite and postfabricated 3D structures on achieving high stretchability. Finally, representative examples of applications of such nanocomposites in biointegrated electronics are provided. A brief outlook concludes this Review.
Collapse
Affiliation(s)
- Hyunwoo Joo
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul, 08826, Republic of Korea
- School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, Seoul, 08826, Republic of Korea
| | - Dongjun Jung
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul, 08826, Republic of Korea
- School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, Seoul, 08826, Republic of Korea
| | - Sung-Hyuk Sunwoo
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul, 08826, Republic of Korea
- School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, Seoul, 08826, Republic of Korea
| | - Ja Hoon Koo
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul, 08826, Republic of Korea
- School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, Seoul, 08826, Republic of Korea
| | - Dae-Hyeong Kim
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul, 08826, Republic of Korea
- School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, Seoul, 08826, Republic of Korea
| |
Collapse
|