Zhang Y, Lu M. Numerical Simulation of Thermal Therapy for Melanoma in Mice. Bioengineering (Basel) 2024; 11:694. [PMID: 39061776 PMCID: PMC11273475 DOI: 10.3390/bioengineering11070694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2024] [Revised: 07/01/2024] [Accepted: 07/03/2024] [Indexed: 07/28/2024] Open
Abstract
In recent years, the progressively escalating incidence and exceptionally high fatality rate of cutaneous melanoma have drawn the attention of numerous scholars. Magnetic induction hyperthermia, as an efficacious tumor treatment modality, has been promoted and applied in the therapy of some tumors. In this paper, the melanoma atop the mice's heads was chosen as the research subject, and a magnetic induction hyperthermia approach based on Helmholtz coils as the magnetic field excitation was investigated and designed. The influence of the electromagnetic field and thermal field on organisms was addressed through modeling by COMSOL simulation software. The results showed that the maximum values of induced electric field and magnetic induction strength in mouse tumor tissues were 63.1 V/m and 8.5621 mT, respectively, which reached the threshold value of magnetic field strength required for magnetic induction hyperthermia. The maxima of the induced electric field and magnetic induction intensity in brain tissues are, respectively, 35.828 V/m and 8.57 mT. Approximately 93% of the tumor tissue can reach 42 °C, and the maximum temperature is 44.2 °C. Within this temperature range, a large quantity of tumor cells can be successfully induced to undergo apoptosis without harming normal cells, and the therapeutic effect is favorable.
Collapse
Affiliation(s)
| | - Mai Lu
- Key Laboratory of Opto-Electronic Technology and Intelligent Control of Ministry of Education, Lanzhou Jiaotong University, Lanzhou 730070, China;
| |
Collapse
|
2
|
Jiao L, Zhang T, Gao P, Zhou C, Mei X, Zhang W, Lu Y, Zhang L, Zhou Z, Yu Z, He M. Exploring and validating heating dynamics in a radio-frequency electromagnetic field-based resonant chamber for mouse hyperthermia research. Electromagn Biol Med 2024; 43:164-175. [PMID: 38859623 DOI: 10.1080/15368378.2024.2361873] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Accepted: 05/26/2024] [Indexed: 06/12/2024]
Abstract
Mild whole-body hyperthermia has been shown to have anti-tumor effects through an immune-modulating mechanism. Before it is widely applied in the clinic, tremendous mechanistic research in animals is necessary to adhere to evidence-based principles. The radio frequency electromagnetic field (RF-EMF) based heating facility could be a good choice for hyperthermia treatment, but the heating characteristics of a facility, including structure design, electromagnetic and thermal dosimetry, and the biologic effects of hyperthermia, need to be well elucidated. Here, we reported the heating characteristic study on a resonant chamber (RC) excited by a 1800 MHz solid source. The EMF in the RC was stirred by 24 static reflectors, which resulted in the standard deviation of electric field intensity being below 3 dB in the EM homogeneity evaluation. For the exposure scenario, six free-moving mice were loaded into separate cases and exposed simultaneously in the RC. The EMF energy absorption and distribution in exposed mice were calculated with the 12-plane-waves method of numerical simulation. Different levels of core body temperature increment in exposed mice were achieved through regulation of the source output power. Overexpression of heat shock proteins (HSPs) was detected in the liver, lung and muscle, but not in the brain of the exposed mice. The levels of representative inflammatory cytokines in the serum, TNF-α and IL-10 increased post RC exposure. Based on the heating characteristic study and validation, the applied RC would be a qualified heating system for mild whole-body hyperthermia effect research in mice.
Collapse
Affiliation(s)
- Lijiao Jiao
- Key Laboratory of Medical Protection for Electromagnetic Radiation, Ministry of Education, Department of Occupational Health, Army Medical University, Chongqing, China
- Department of Nursing, General Hospital of Northern Theater Command, Shenyang, Liaoning Province, People's Republic of China
| | - Tao Zhang
- Key Laboratory of Medical Protection for Electromagnetic Radiation, Ministry of Education, Department of Occupational Health, Army Medical University, Chongqing, China
| | - Peng Gao
- Key Laboratory of Medical Protection for Electromagnetic Radiation, Ministry of Education, Department of Occupational Health, Army Medical University, Chongqing, China
| | - Chao Zhou
- Key Laboratory of Medical Protection for Electromagnetic Radiation, Ministry of Education, Department of Occupational Health, Army Medical University, Chongqing, China
- Xizang Autonomous Region, China
| | - Xiang Mei
- Key Laboratory of Medical Protection for Electromagnetic Radiation, Ministry of Education, Department of Occupational Health, Army Medical University, Chongqing, China
| | - Wenjuan Zhang
- Key Laboratory of Medical Protection for Electromagnetic Radiation, Ministry of Education, Department of Occupational Health, Army Medical University, Chongqing, China
| | - Yonghui Lu
- Key Laboratory of Medical Protection for Electromagnetic Radiation, Ministry of Education, Department of Occupational Health, Army Medical University, Chongqing, China
| | - Lei Zhang
- Key Laboratory of Medical Protection for Electromagnetic Radiation, Ministry of Education, Department of Occupational Health, Army Medical University, Chongqing, China
| | - Zhou Zhou
- Center for Neurointelligence, School of Medicine, Chongqing University, Chongqing, China
| | - Zhengping Yu
- Key Laboratory of Medical Protection for Electromagnetic Radiation, Ministry of Education, Department of Occupational Health, Army Medical University, Chongqing, China
| | - Mindi He
- Key Laboratory of Medical Protection for Electromagnetic Radiation, Ministry of Education, Department of Occupational Health, Army Medical University, Chongqing, China
| |
Collapse
|
3
|
Khadir Fall A, Lemoine C, Besnier P, Sauleau R, Le Dréan Y, Zhadobov M. Exposure Assessment in Millimeter-Wave Reverberation Chamber Using Murine Phantoms. Bioelectromagnetics 2020; 41:121-135. [PMID: 31943296 DOI: 10.1002/bem.22243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Accepted: 12/14/2019] [Indexed: 11/12/2022]
Abstract
This study deals with the design and calibration of the first mode-stirred reverberation chamber (RC) in the 60-GHz-band adapted for in vivo bioelectromagnetic studies. In addition to the interface for electromagnetic and thermal dosimetry, the interfaces for lighting and ventilation were integrated into the RC walls while preserving acceptable shielding. The RC with mechanical and electronic steering capabilities is characterized in the 55-65 GHz range. To this end, murine skin-equivalent phantoms of realistic shape were designed and fabricated. Their complex permittivity is within ±12% of the target value of murine skin (6.19-j5.81 at 60 GHz). The quality factor of the RC loaded with an animal cage, bedding litter, and five murine phantoms was found to be 1.2 × 104 . The losses inside the RC were analyzed, and it was demonstrated that the main sources of the power dissipation were the phantoms and mice cage. The input power required to reach the average incident power density of 1 and 5 mW/cm2 was found to be 0.23 and 1.14 W, respectively. Surface heating of the mice models was measured in the infrared (IR) range using a specifically designed interface, transparent at IR and opaque at millimeter waves (mmW). Experimental results were compared with an analytical solution of the heat transfer equation and to full-wave computations. Analytical and numerical results were in very good agreement with measurements (the relative deviation after 90 min of exposure was within 4.2%). Finally, a parametric study was performed to assess the impact of the thermophysical parameters on the resulting heating. Bioelectromagnetics. 2020;41:121-135. © 2020 Bioelectromagnetics Society.
Collapse
Affiliation(s)
- Abdou Khadir Fall
- Univ Rennes, INSA Rennes, CNRS, IETR-UMR 6164, F-35000 Rennes, France
| | | | - Philippe Besnier
- Univ Rennes, INSA Rennes, CNRS, IETR-UMR 6164, F-35000 Rennes, France
| | - Ronan Sauleau
- Univ Rennes, INSA Rennes, CNRS, IETR-UMR 6164, F-35000 Rennes, France
| | - Yves Le Dréan
- IRSET-UMR_S 1085, University of Rennes, Rennes, France
| | - Maxim Zhadobov
- Univ Rennes, INSA Rennes, CNRS, IETR-UMR 6164, F-35000 Rennes, France
| |
Collapse
|
4
|
Hansen JW, Swartz EM, Cleveland JD, Asif SM, Brooks B, Braaten BD, Ewert DL. A Systematic Review of In Vitro and In Vivo Radio Frequency Exposure Methods. IEEE Rev Biomed Eng 2019; 13:340-351. [PMID: 30998481 DOI: 10.1109/rbme.2019.2912023] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Recently, interest in the effects of radio frequency (RF) on biological systems has increased and is partially due to the advancements and increased implementations of RF into technology. As research in this area has progressed, the reliability and reproducibility of the experiments has not crossed multidisciplinary boundaries. Therefore, as researchers, it is imperative to understand the various exposure systems available as well as the aspects, both electromagnetic and biological, needed to produce a sound exposure experiment. This systematic review examines common RF exposure methods for both in vitro and in vivo studies. For in vitro studies, possible biological limitations are emphasized. The validity of the examined methods, for both in vitro and in vivo, are analyzed by considering the advantages and disadvantages of each. This review offers guidance for researchers to assist in the development of an RF exposure experiment that crosses current multidisciplinary boundaries.
Collapse
|
5
|
Wyde ME, Horn TL, Capstick MH, Ladbury JM, Koepke G, Wilson PF, Kissling GE, Stout MD, Kuster N, Melnick RL, Gauger J, Bucher JR, McCormick DL. Effect of cell phone radiofrequency radiation on body temperature in rodents: Pilot studies of the National Toxicology Program's reverberation chamber exposure system. Bioelectromagnetics 2018. [PMID: 29537695 DOI: 10.1002/bem.22116] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Radiofrequency radiation (RFR) causes heating, which can lead to detrimental biological effects. To characterize the effects of RFR exposure on body temperature in relation to animal size and pregnancy, a series of short-term toxicity studies was conducted in a unique RFR exposure system. Young and old B6C3F1 mice and young, old, and pregnant Harlan Sprague-Dawley rats were exposed to Global System for Mobile Communication (GSM) or Code Division Multiple Access (CDMA) RFR (rats = 900 MHz, mice = 1,900 MHz) at specific absorption rates (SARs) up to 12 W/kg for approximately 9 h a day for 5 days. In general, fewer and less severe increases in body temperature were observed in young than in older rats. SAR-dependent increases in subcutaneous body temperatures were observed at exposures ≥6 W/kg in both modulations. Exposures of ≥10 W/kg GSM or CDMA RFR induced excessive increases in body temperature, leading to mortality. There was also a significant increase in the number of resorptions in pregnant rats at 12 W/kg GSM RFR. In mice, only sporadic increases in body temperature were observed regardless of sex or age when exposed to GSM or CDMA RFR up to 12 W/kg. These results identified SARs at which measurable RFR-mediated thermal effects occur, and were used in the selection of exposures for subsequent toxicology and carcinogenicity studies. Bioelectromagnetics. 39:190-199, 2018. © 2018 The Authors. Bioelectromagnetics Published by Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Michael E Wyde
- National Toxicology Program, National Institute of Environmental Health Sciences, Research Triangle Park, North Carolina
| | | | | | - John M Ladbury
- National Institute of Standards and Technology, Boulder, Colorado
| | - Galen Koepke
- National Institute of Standards and Technology, Boulder, Colorado
| | - Perry F Wilson
- National Institute of Standards and Technology, Boulder, Colorado
| | - Grace E Kissling
- National Toxicology Program, National Institute of Environmental Health Sciences, Research Triangle Park, North Carolina
| | - Matthew D Stout
- National Toxicology Program, National Institute of Environmental Health Sciences, Research Triangle Park, North Carolina
| | | | - Ronald L Melnick
- National Toxicology Program, National Institute of Environmental Health Sciences, Research Triangle Park, North Carolina
| | | | - John R Bucher
- National Toxicology Program, National Institute of Environmental Health Sciences, Research Triangle Park, North Carolina
| | | |
Collapse
|
6
|
Gong Y, Capstick M, Kuehn S, Wilson P, Ladbury J, Koepke G, McCormick DL, Melnick RL, Kuster N. Life-Time Dosimetric Assessment for Mice and Rats Exposed in Reverberation Chambers of the 2-Year NTP Cancer Bioassay Study on Cell Phone Radiation. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY 2017; 59:1798-1808. [PMID: 29217849 PMCID: PMC5714545 DOI: 10.1109/temc.2017.2665039] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
In this paper, we present the detailed life-time dosimetry analysis for rodents exposed in the reverberation exposure system designed for the two-year cancer bioassay study conducted by the National Toxicology Program of the National Institute of Environmental Health Sciences. The study required the well-controlled and characterized exposure of individually housed, unrestrained mice at 1900 MHz and rats at 900 MHz, frequencies chosen to give best uniformity exposure of organs and tissues. The wbSAR, the peak spatial SAR and the organ specific SAR as well as the uncertainty and variation due to the exposure environment, differences in the growth rates, and animal posture were assessed. Compared to the wbSAR, the average exposure of the high-water-content tissues (blood, heart, lung) were higher by ~4 dB, while the low-loss tissues (bone and fat) were less by ~9 dB. The maximum uncertainty over the exposure period for the SAR was estimated to be <49% (k=2) for the rodents whereas the relative uncertainty between the group was <14% (k=1). The instantaneous variation (averaged over 1 min) was <13% (k=1), which is small compared to other long term exposure research projects. These detailed dosimetric results empowers comparison with other studies and provides a reference for studies of long-term biological effects of exposure of rodents to RF energy.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | - Niels Kuster
- IT'IS Foundation and the Swiss Federal Institute of Technology, Switzerland
| |
Collapse
|
7
|
Capstick M, Gong Y, Pasche B, Kuster N. An HF exposure system for mice with improved efficiency. Bioelectromagnetics 2016; 37:223-33. [DOI: 10.1002/bem.21969] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2015] [Accepted: 03/02/2016] [Indexed: 11/05/2022]
Affiliation(s)
| | - Yijian Gong
- IT'IS Foundation; ETH Zürich; Zürich Switzerland
- Integrated System Laboratory; ETH Zürich; Zürich Switzerland
| | - Boris Pasche
- Department of Cancer Biology; Wake Forest Baptist Comprehensive Cancer Center; Winston-Salem North Carolina
| | - Niels Kuster
- IT'IS Foundation; ETH Zürich; Zürich Switzerland
- Integrated System Laboratory; ETH Zürich; Zürich Switzerland
| |
Collapse
|