1
|
Mohanta Z, Gori S, McMahon MT. Intramolecular Hydrogen Bonding Based CEST MRI Contrast Agents As an Emerging Design Strategy: A Mini-Review. ACS OMEGA 2024; 9:27755-27765. [PMID: 38973929 PMCID: PMC11223143 DOI: 10.1021/acsomega.4c02296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Revised: 05/21/2024] [Accepted: 06/05/2024] [Indexed: 07/09/2024]
Abstract
Intramolecular hydrogen bonding-based chemical exchange saturation transfer magnetic resonance imaging (CEST MRI) contrast agents represent an innovative design strategy aiming to overcome limitations in diamagnetic CEST (diaCEST) MRI contrast agent specificity and also those associated with traditional metal-based MRI contrast agents. Ward and Balaban's proposal of small diamagnetic compounds marked a paradigm shift in contrast-based radiologic research, inspiring extensive investigations since 2000. These contrast agents leverage labile hydrogen bonds, serving as chemical exchange sites to induce saturation of water. The selective manipulation of radiofrequency (RF) allows for optimized signal contrast in soft tissue, with a significant signal amplification even at low probe concentrations, mitigating concerns about dose-dependent toxicities. This mini-review delves into the evolution of CEST MRI, its classification, and the strategic design principles of synthetic small molecules containing intramolecular hydrogen bonds. With a focus on applications and potential clinical relevance, the authors highlight the promising role of intramolecular hydrogen bonding-based CEST MRI in diverse medical contexts, especially renal imaging and pH mapping, paving the way for enhanced molecular imaging capabilities. Ongoing research endeavors aim to further optimize and expand the utility of these contrast agents, underscoring their transformative potential in clinical diagnostics and imaging.
Collapse
Affiliation(s)
- Zinia Mohanta
- Russell
H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, United States
- F.M.
Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland 21205, United States
| | - Sadakatali Gori
- Center
for Translational Pharmacology, Department of Pharmacy and Pharmaceutical
Sciences, St. Jude Children’s Research
Hospital, Memphis, Tennessee 38105-3678, United States
| | - Michael T. McMahon
- Russell
H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, United States
- F.M.
Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland 21205, United States
| |
Collapse
|
2
|
Longo DL, Carella A, Corrado A, Pirotta E, Mohanta Z, Singh A, Stabinska J, Liu G, McMahon MT. A snapshot of the vast array of diamagnetic CEST MRI contrast agents. NMR IN BIOMEDICINE 2023; 36:e4715. [PMID: 35187749 PMCID: PMC9724179 DOI: 10.1002/nbm.4715] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 02/17/2022] [Accepted: 02/18/2022] [Indexed: 05/11/2023]
Abstract
Since the inception of CEST MRI in the 1990s, a number of compounds have been identified as suitable for generating contrast, including paramagnetic lanthanide complexes, hyperpolarized atom cages and, most interesting, diamagnetic compounds. In the past two decades, there has been a major emphasis in this field on the identification and application of diamagnetic compounds that have suitable biosafety profiles for usage in medical applications. Even in the past five years there has been a tremendous growth in their numbers, with more and more emphasis being placed on finding those that can be ultimately used for patient studies on clinical 3 T scanners. At this point, a number of endogenous compounds present in tissue have been identified, and also natural and synthetic organic compounds that can be administered to highlight pathology via CEST imaging. Here we will provide a very extensive snapshot of the types of diamagnetic compound that can generate CEST MRI contrast, together with guidance on their utility on typical preclinical and clinical scanners and a review of the applications that might benefit the most from this new technology.
Collapse
Affiliation(s)
- Dario Livio Longo
- Institute of Biostructures and Bioimaging (IBB), National Research Council of Italy (CNR), Turin, Italy
| | - Antonella Carella
- Institute of Biostructures and Bioimaging (IBB), National Research Council of Italy (CNR), Turin, Italy
| | - Alessia Corrado
- Institute of Biostructures and Bioimaging (IBB), National Research Council of Italy (CNR), Turin, Italy
| | - Elisa Pirotta
- Institute of Biostructures and Bioimaging (IBB), National Research Council of Italy (CNR), Turin, Italy
| | - Zinia Mohanta
- F.M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Aruna Singh
- F.M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Julia Stabinska
- F.M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Guanshu Liu
- F.M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Michael T. McMahon
- F.M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| |
Collapse
|
3
|
Bo S, Zhang D, Ma M, Mo X, Stabinska J, McMahon MT, Shi C, Luo L. Acyl Hydrazides and Acyl Hydrazones as High-Performance Chemical Exchange Saturation Transfer MRI Contrast Agents. Pharmaceuticals (Basel) 2023; 16:ph16050639. [PMID: 37242423 DOI: 10.3390/ph16050639] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 04/17/2023] [Accepted: 04/20/2023] [Indexed: 05/28/2023] Open
Abstract
Chemical exchange saturation transfer (CEST) MRI is a versatile molecular imaging approach that holds great promise for clinical translation. A number of compounds have been identified as suitable for performing CEST MRI, including paramagnetic CEST (paraCEST) agents and diamagnetic CEST (diaCEST) agents. DiaCEST agents are very attractive because of their excellent biocompatibility and potential for biodegradation, such as glucose, glycogen, glutamate, creatine, nucleic acids, et al. However, the sensitivity of most diaCEST agents is limited because of small chemical shifts (1.0-4.0 ppm) from water. To expand the catalog of diaCEST agents with larger chemical shifts, herein, we have systematically investigated the CEST properties of acyl hydrazides with different substitutions, including aromatic and aliphatic substituents. We have tuned the labile proton chemical shifts from 2.8-5.0 ppm from water while exchange rates varied from ~680 to 2340 s-1 at pH 7.2, which allows strong CEST contrast on scanners down to B0 = 3 T. One acyl hydrazide, adipic acid dihydrazide (ADH), was tested on a mouse model of breast cancer and showed nice contrast in the tumor region. We also prepared a derivative, acyl hydrazone, which showed the furthest shifted labile proton (6.4 ppm from water) and excellent contrast properties. Overall, our study expands the catalog of diaCEST agents and their application in cancer diagnosis.
Collapse
Affiliation(s)
- Shaowei Bo
- Department of Medical Imaging, The Affiliated Guangdong Second Provincial General Hospital of Jinan University, Guangzhou 510317, China
| | - Dong Zhang
- Medical Imaging Center, The First Affiliated Hospital of Jinan University, Guangzhou 510632, China
| | - Mengjie Ma
- Medical Imaging Center, The First Affiliated Hospital of Jinan University, Guangzhou 510632, China
| | - Xukai Mo
- Medical Imaging Center, The First Affiliated Hospital of Jinan University, Guangzhou 510632, China
| | - Julia Stabinska
- The Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD 21287, USA
| | - Michael T McMahon
- The Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD 21287, USA
| | - Changzheng Shi
- Medical Imaging Center, The First Affiliated Hospital of Jinan University, Guangzhou 510632, China
| | - Liangping Luo
- Department of Medical Imaging, The Affiliated Guangdong Second Provincial General Hospital of Jinan University, Guangzhou 510317, China
- Medical Imaging Center, The First Affiliated Hospital of Jinan University, Guangzhou 510632, China
| |
Collapse
|
4
|
Kombala CJ, Kotrotsou A, Schuler FW, de la Cerda J, Ma JC, Zhang S, Pagel MD. Development of a Nanoscale Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Contrast Agent That Measures pH. ACS NANO 2021; 15:20678-20688. [PMID: 34870957 DOI: 10.1021/acsnano.1c10107] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
AcidoCEST MRI can measure the extracellular pH (pHe) of the tumor microenvironment in mouse models of human cancers and in patients who have cancer. However, chemical exchange saturation transfer (CEST) is an insensitive magnetic resonance imaging (MRI) contrast mechanism, requiring a high concentration of small-molecule agent to be delivered to the tumor. Herein, we developed a nanoscale CEST agent that can measure pH using acidoCEST MRI, which may decrease the requirement for high delivery concentrations of agent. We also developed a monomer agent for comparison to the polymer. After optimizing CEST experimental conditions, we determined that the polymer agent could be used during acidoCEST MRI studies at 125-fold and 488-fold lower concentration than the monomer agent and iopamidol, respectively. We also determined that both agents can measure pH with negligible dependence on temperature. However, pH measurements with both agents were dependent on concentration, which may be due to concentration-dependent changes in hydrogen bonding and/or steric hindrance. We performed in vivo acidoCEST MRI studies using the three agents to study a xenograft MDA-MB-231 model of mammary carcinoma. The tumor pHe measurements were 6.33 ± 0.12, 6.70 ± 0.15, and 6.85 ± 0.15 units with iopamidol, the monomer agent, and polymer agent, respectively. The higher pHe measurements with the monomer and polymer agents were attributed to the concentration dependence of these agents. This study demonstrated that nanoscale agents have merit for CEST MRI studies, but consideration should be given to the dependence of CEST contrast on the concentration of these agents.
Collapse
Affiliation(s)
- Chathuri J Kombala
- Department of Chemistry and Biochemistry, University of Arizona, Tucson, Arizona 85721, United States
- Department of Cancer Systems Imaging, University of Texas MD Anderson Cancer Center, Houston, Texas 77054, United States
| | - Aikaterini Kotrotsou
- Department of Cancer Systems Imaging, University of Texas MD Anderson Cancer Center, Houston, Texas 77054, United States
| | - F William Schuler
- Department of Cancer Systems Imaging, University of Texas MD Anderson Cancer Center, Houston, Texas 77054, United States
| | - Jorge de la Cerda
- Department of Cancer Systems Imaging, University of Texas MD Anderson Cancer Center, Houston, Texas 77054, United States
| | - Jacqueline C Ma
- Department of Cancer Systems Imaging, University of Texas MD Anderson Cancer Center, Houston, Texas 77054, United States
| | - Shu Zhang
- Department of Cancer Systems Imaging, University of Texas MD Anderson Cancer Center, Houston, Texas 77054, United States
| | - Mark D Pagel
- Department of Cancer Systems Imaging, University of Texas MD Anderson Cancer Center, Houston, Texas 77054, United States
| |
Collapse
|
5
|
Kombala CJ, Lokugama SD, Kotrotsou A, Li T, Pollard AC, Pagel MD. Simultaneous Evaluations of pH and Enzyme Activity with a CEST MRI Contrast Agent. ACS Sens 2021; 6:4535-4544. [PMID: 34856102 DOI: 10.1021/acssensors.1c02408] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The extracellular tumor microenvironment of many solid tumors has high acidosis and high protease activity. Simultaneously assessing both characteristics may improve diagnostic evaluations of aggressive tumors and the effects of anticancer treatments. Noninvasive imaging methods have previously been developed that measure extracellular pH or can detect enzyme activity using chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI). Herein, we developed a single-hybrid CEST agent that can simultaneously measure pH and evaluate protease activity using a combination of dual-power acidoCEST MRI and catalyCEST MRI. Our agent showed CEST signals at 9.2 ppm from a salicylic acid moiety and at 5.0 ppm from an aryl amide. The CEST signal at 9.2 ppm could be measured after selective saturation was applied at 1 and 4 μT, and these measurements could be used with a ratiometric analysis to determine pH. The CEST signal at 5.0 ppm from the aryl amide disappeared after the agent was treated with cathepsin B, while the CEST signal at 9.2 ppm remained, indicating that the agent could detect protease activity through the amide bond cleavage. Michaelis-Menten kinetics studies with catalyCEST MRI demonstrated that the binding affinity (as shown with the Michaelis constant KM), the catalytic turnover rate (kcat), and catalytic efficiency (kcat/KM) were each higher for cathepsin B at lower pH. The kcat rates measured with catalyCEST MRI were lower than the comparable rates measured with liquid chromatography-mass spectrometry (LC-MS), which reflected a limitation of inherently noisy and relatively insensitive CEST MRI analyses. Although this level of precision limited catalyCEST MRI to semiquantitative evaluations, these semiquantitative assessments of high and low protease activity still had value by demonstrating that high acidosis and high protease activity can be used as synergistic, multiparametric biomarkers.
Collapse
Affiliation(s)
- Chathuri J. Kombala
- Department of Chemistry and Biochemistry, University of Arizona, Tucson, Arizona 85721, United States
- Department of Cancer Systems Imaging, University of Texas MD Anderson Cancer Center, Houston, Texas 77054, United States
| | - Sanjaya D. Lokugama
- Department of Chemistry and Biochemistry, University of Arizona, Tucson, Arizona 85721, United States
- Department of Cancer Systems Imaging, University of Texas MD Anderson Cancer Center, Houston, Texas 77054, United States
| | - Aikaterini Kotrotsou
- Department of Cancer Systems Imaging, University of Texas MD Anderson Cancer Center, Houston, Texas 77054, United States
| | - Tianzhe Li
- Department of Cancer Systems Imaging, University of Texas MD Anderson Cancer Center, Houston, Texas 77054, United States
| | - Alyssa C. Pollard
- Department of Cancer Systems Imaging, University of Texas MD Anderson Cancer Center, Houston, Texas 77054, United States
- Department of Chemistry, Rice University, Houston, Texas 77251, United States
| | - Mark D. Pagel
- Department of Cancer Systems Imaging, University of Texas MD Anderson Cancer Center, Houston, Texas 77054, United States
| |
Collapse
|
6
|
Lombardi AF, Wong JH, High R, Ma Y, Jerban S, Tang Q, Du J, Frost P, Pagel MD, Chang EY. AcidoCEST MRI Evaluates the Bone Microenvironment in Multiple Myeloma. Mol Imaging Biol 2021; 23:865-873. [PMID: 33939066 PMCID: PMC8563482 DOI: 10.1007/s11307-021-01611-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2021] [Revised: 04/14/2021] [Accepted: 04/26/2021] [Indexed: 01/29/2023]
Abstract
PURPOSE Multiple myeloma (MM) is an incurable disease of malignant plasma cells in the bone marrow (BM). Adaptive responses to hypoxia may be an essential element in MM progression and drug resistance. This metabolic adaptation involves a decrease in extracellular pH (pHe), and it depends on the upregulation of glucose transporters (GLUTs) that is common in hypoxia and in cancer cells. CEST MRI is an imaging technique that assesses pHe indirectly by the exchange rate of magnetic saturation transfer between labile protons on a solute and water. Thus, this study aimed to determine the feasibility of acidoCEST MRI for pHe measurement using an orthotopic mouse model of MM compared with GLUT1 immunofluorescence staining as a reference. PROCEDURES Orthotopic BM engrafted MM xenografts were established in NSG/NOD mice using the human RPMI8226 myeloma cell line. AcidoCEST MRI was performed approximately 6 weeks after intravenous challenge, before and after intravenous administration of iopamidol. BM pHe values were generated via fitting the CEST spectrum with the Bloch-McConnell equations. Samples were decalcified, sectioned, and immunostained for GLUT1 expression. Pearson's correlation was used to assess the relationship between pHe and [H3O+] versus GLUT1 expression. RESULTS Ten mice underwent acidoCEST MRI followed by immunofluorescent histologic analysis. A strong negative correlation was seen between pHe versus GLUT1 expression (r = - 0.75, p < 0.001). After transformation of pH to [H3O+], a strong positive correlation between [H3O+] and GLUT1 expression was observed (r = 0.8, p < 0.001). CONCLUSIONS AcidoCEST MRI can measure the extracellular pH of bone marrow affected by multiple myeloma. In this MM orthotopic mouse model, pHe measured by acidoCEST MRI showed strong correlations with the metabolic phenotype of BM tumor assessed by immunofluorescent histological assessment of GLUT1 overexpression.
Collapse
Affiliation(s)
- Alecio F Lombardi
- Research Service, VA San Diego Healthcare System, 3350 La Jolla Village Drive, CA, 92161, San Diego, USA
- Department of Radiology, University of California, San Diego, CA, USA
| | - Jonathan H Wong
- Research Service, VA San Diego Healthcare System, 3350 La Jolla Village Drive, CA, 92161, San Diego, USA
- Department of Radiology, University of California, San Diego, CA, USA
| | - Rachel High
- Research Service, VA San Diego Healthcare System, 3350 La Jolla Village Drive, CA, 92161, San Diego, USA
- Department of Radiology, University of California, San Diego, CA, USA
| | - Yajun Ma
- Research Service, VA San Diego Healthcare System, 3350 La Jolla Village Drive, CA, 92161, San Diego, USA
- Department of Radiology, University of California, San Diego, CA, USA
| | - Saeed Jerban
- Research Service, VA San Diego Healthcare System, 3350 La Jolla Village Drive, CA, 92161, San Diego, USA
- Department of Radiology, University of California, San Diego, CA, USA
| | - Qingbo Tang
- Research Service, VA San Diego Healthcare System, 3350 La Jolla Village Drive, CA, 92161, San Diego, USA
- Department of Radiology, University of California, San Diego, CA, USA
| | - Jiang Du
- Research Service, VA San Diego Healthcare System, 3350 La Jolla Village Drive, CA, 92161, San Diego, USA
- Department of Radiology, University of California, San Diego, CA, USA
| | - Patrick Frost
- Research Service, Greater Los Angeles Veteran Administration Healthcare System, Los Angeles, CA, USA
- Department of Medicine, University of California, Los Angeles, CA, USA
| | - Mark D Pagel
- Department of Cancer Systems Imaging, University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Eric Y Chang
- Research Service, VA San Diego Healthcare System, 3350 La Jolla Village Drive, CA, 92161, San Diego, USA.
- Department of Radiology, University of California, San Diego, CA, USA.
| |
Collapse
|
7
|
Abstract
Cysteine cathepsins are proteases critical in physiopathological processes and show potential as targets or biomarkers for diseases and medical conditions. The 11 members of the cathepsin family are redundant in some cases but remarkably independent of others, demanding the development of both pan-cathepsin targeting tools as well as probes that are selective for specific cathepsins with little off-target activity. This review addresses the diverse design strategies that have been employed to accomplish this tailored selectivity among cysteine cathepsin targets and the imaging modalities incorporated. The power of these diverse tools is contextualized by briefly highlighting the nature of a few prominent cysteine cathepsins, their involvement in select diseases, and the application of cathepsin imaging probes in research spanning basic biochemical studies to clinical applications.
Collapse
Affiliation(s)
- Kelton A Schleyer
- Department of Medicinal Chemistry, College of Pharmacy, University of Florida, 1345 Center Dr, Gainesville, FL 32610, USA.
| | - Lina Cui
- Department of Medicinal Chemistry, College of Pharmacy, University of Florida, 1345 Center Dr, Gainesville, FL 32610, USA.
| |
Collapse
|
8
|
Liu G, van Zijl PC. CEST (Chemical Exchange Saturation Transfer) MR Molecular Imaging. Mol Imaging 2021. [DOI: 10.1016/b978-0-12-816386-3.00012-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
9
|
Repurposing Clinical Agents for Chemical Exchange Saturation Transfer Magnetic Resonance Imaging: Current Status and Future Perspectives. Pharmaceuticals (Basel) 2020; 14:ph14010011. [PMID: 33374213 PMCID: PMC7824058 DOI: 10.3390/ph14010011] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2020] [Revised: 12/19/2020] [Accepted: 12/21/2020] [Indexed: 12/24/2022] Open
Abstract
Molecular imaging is becoming an indispensable tool to pursue precision medicine. However, quickly translating newly developed magnetic resonance imaging (MRI) agents into clinical use remains a formidable challenge. Recently, Chemical Exchange Saturation Transfer (CEST) MRI is emerging as an attractive approach with the capability of directly using low concentration, exchangeable protons-containing agents for generating quantitative MRI contrast. The ability to utilize diamagnetic compounds has been extensively exploited to detect many clinical compounds, such as FDA approved drugs, X-ray/CT contrast agents, nutrients, supplements, and biopolymers. The ability to directly off-label use clinical compounds permits CEST MRI to be rapidly translated to clinical settings. In this review, the current status of CEST MRI based on clinically available compounds will be briefly introduced. The advancements and limitations of these studies are reviewed in the context of their pre-clinical or clinical applications. Finally, future directions will be briefly discussed.
Collapse
|
10
|
Li Y, Mei T, Han S, Han T, Sun Y, Zhang H, An F. Cathepsin B-responsive nanodrug delivery systems for precise diagnosis and targeted therapy of malignant tumors. CHINESE CHEM LETT 2020. [DOI: 10.1016/j.cclet.2020.05.027] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
11
|
Goldenberg JM, Pagel MD. Assessments of tumor metabolism with CEST MRI. NMR IN BIOMEDICINE 2019; 32:e3943. [PMID: 29938857 PMCID: PMC7377947 DOI: 10.1002/nbm.3943] [Citation(s) in RCA: 56] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Revised: 04/13/2018] [Accepted: 04/18/2018] [Indexed: 05/06/2023]
Abstract
Chemical exchange saturation transfer (CEST) is a relatively new contrast mechanism for MRI. CEST MRI exploits a specific MR frequency (chemical shift) of a molecule while generating an image with good spatial resolution using standard MRI techniques, combining the specificity of MRS with the spatial resolution of MRI. Many CEST MRI acquisition methods have been developed to improve analyses of tumor metabolism. GluCEST, CrCEST, and LATEST can map glutamate, creatine, and lactate, which are important metabolites involved in tumor metabolism. GlucoCEST MRI tracks the pharmacokinetics of glucose transport and cell internalization within tumors. CatalyCEST MRI detects enzyme catalysis that changes a substrate CEST agent. AcidoCEST MRI measures extracellular pH of the tumor microenvironment by exploiting a ratio of two pH-dependent CEST signals. This review describes each technique, the technical issues involved with CEST MRI and each specific technique, and the merits and challenges associated with applying each CEST MRI technique to study tumor metabolism.
Collapse
Affiliation(s)
- Joshua M. Goldenberg
- Department of Pharmaceutical Sciences, The University of Arizona, Tucson, AZ, USA
- Department of Cancer Systems Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Mark D. Pagel
- Department of Cancer Systems Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| |
Collapse
|
12
|
Lindeman LR, Jones KM, High RA, Howison CM, Shubitz LF, Pagel MD. Differentiating lung cancer and infection based on measurements of extracellular pH with acidoCEST MRI. Sci Rep 2019; 9:13002. [PMID: 31506562 PMCID: PMC6736855 DOI: 10.1038/s41598-019-49514-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2018] [Accepted: 08/27/2019] [Indexed: 01/17/2023] Open
Abstract
Lung cancer diagnosis via imaging may be confounded by the presence of indolent infectious nodules in imaging studies. This issue is pervasive in the southwestern US where coccidioidomycosis (Valley Fever) is endemic. AcidoCEST MRI is a noninvasive imaging method that quantifies the extracellular pH (pHe) of tissues in vivo, allowing tumor acidosis to be used as a diagnostic biomarker. Using murine models of lung adenocarcinoma and coccidoidomycosis, we found that average lesion pHe differed significantly between tumors and granulomas. Our study shows that acidoCEST MRI is a promising tool for improving the specificity of lung cancer diagnosis.
Collapse
Affiliation(s)
- Leila R Lindeman
- Cancer Biology Graduate Interdisciplinary Program, University of Arizona, Tucson, AZ, USA
| | - Kyle M Jones
- Bioengineering Graduate Interdisciplinary Program, University of Arizona, Tucson, AZ, USA
| | - Rachel A High
- Cancer Biology Graduate Interdisciplinary Program, University of Arizona, Tucson, AZ, USA
| | | | - Lisa F Shubitz
- Valley Fever Center for Excellence, University of Arizona, Tucson, AZ, USA
| | - Mark D Pagel
- Department of Cancer Systems Imaging, MD Anderson Cancer Center, Houston, TX, USA.
| |
Collapse
|
13
|
Pavuluri K, Manoli I, Pass A, Li Y, Vernon HJ, Venditti CP, McMahon MT. Noninvasive monitoring of chronic kidney disease using pH and perfusion imaging. SCIENCE ADVANCES 2019; 5:eaaw8357. [PMID: 31453331 PMCID: PMC6693904 DOI: 10.1126/sciadv.aaw8357] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Accepted: 07/08/2019] [Indexed: 05/18/2023]
Abstract
Chronic Kidney Disease (CKD) is a cardinal feature of methylmalonic acidemia (MMA), a prototypic organic acidemia. Impaired growth, low activity, and protein restriction affect muscle mass and lower serum creatinine, which can delay diagnosis and management of renal disease. We have designed an alternative strategy for monitoring renal function based on administration of a pH sensitive MRI agent and assessed this in a mouse model. This protocol produced three metrics: kidney contrast, ~4% for severe renal disease mice compared to ~13% and ~25% for moderate renal disease and healthy controls, filtration fraction (FF), ~15% for severe renal disease mice compared to ~79% and 100% for moderate renal disease and healthy controls, and variation in pH, ~0.45 units for severe disease mice compared to 0.06 and 0.01 for moderate disease and healthy controls. Our results demonstrate that MRI can be used for early detection and monitoring of CKD.
Collapse
Affiliation(s)
- KowsalyaDevi Pavuluri
- Division of MR Research, The Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Irini Manoli
- Medical Genomics and Metabolic Genetics Branch, National Human Genome Research Institute, National Institutes of Health (NIH), Bethesda, MD, USA
| | - Alexandra Pass
- Medical Genomics and Metabolic Genetics Branch, National Human Genome Research Institute, National Institutes of Health (NIH), Bethesda, MD, USA
| | - Yuguo Li
- Division of MR Research, The Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Hilary J. Vernon
- McKusick-Nathans Institute of Genetic Medicine, Department of Pediatrics, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Charles P. Venditti
- Medical Genomics and Metabolic Genetics Branch, National Human Genome Research Institute, National Institutes of Health (NIH), Bethesda, MD, USA
| | - Michael T. McMahon
- Division of MR Research, The Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| |
Collapse
|
14
|
Neutrophil Elastase Activity Imaging: Recent Approaches in the Design and Applications of Activity-Based Probes and Substrate-Based Probes. CONTRAST MEDIA & MOLECULAR IMAGING 2019; 2019:7417192. [PMID: 31281234 PMCID: PMC6594253 DOI: 10.1155/2019/7417192] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/28/2019] [Accepted: 05/19/2019] [Indexed: 02/07/2023]
Abstract
The last few decades of protease research has confirmed that a number of important biological processes are strictly dependent on proteolysis. Neutrophil elastase (NE) is a critical protease in immune response and host defense mechanisms in both physiological and disease-associated conditions. Particularly, NE has been identified as a promising biomarker for early diagnosis of lung inflammation. Recent studies have shown an increasing interest in developing methods for NE activity imaging both in vitro and in vivo. Unlike anatomical imaging modalities, functional molecular imaging, including enzymatic activities, enables disease detection at a very early stage and thus constitutes a much more accurate approach. When combined with advanced imaging technologies, opportunities arise for measuring imbalanced proteolytic activities with unprecedented details. Such technologies consist in building the highest resolved and sensitive instruments as well as the most specific probes based either on peptide substrates or on covalent inhibitors. This review outlines strengths and weaknesses of these technologies and discuss their applications to investigate NE activity as biomarker of pulmonary inflammatory diseases by imaging.
Collapse
|
15
|
Ntziachristos V, Pleitez MA, Aime S, Brindle KM. Emerging Technologies to Image Tissue Metabolism. Cell Metab 2019; 29:518-538. [PMID: 30269982 DOI: 10.1016/j.cmet.2018.09.004] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2018] [Revised: 07/24/2018] [Accepted: 09/02/2018] [Indexed: 12/19/2022]
Abstract
Due to the implication of altered metabolism in a large spectrum of tissue function and disease, assessment of metabolic processes becomes essential in managing health. In this regard, imaging can play a critical role in allowing observation of biochemical and physiological processes. Nuclear imaging methods, in particular positron emission tomography, have been widely employed for imaging metabolism but are mainly limited by the use of ionizing radiation and the sensing of only one parameter at each scanning session. Observations in healthy individuals or longitudinal studies of disease could markedly benefit from non-ionizing, multi-parameter imaging methods. We therefore focus this review on progress with the non-ionizing radiation methods of MRI, hyperpolarized magnetic resonance and magnetic resonance spectroscopy, chemical exchange saturation transfer, and emerging optoacoustic (photoacoustic) imaging. We also briefly discuss the role of nuclear and optical imaging methods for research and clinical protocols.
Collapse
Affiliation(s)
- Vasilis Ntziachristos
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg 85764, Germany; Chair of Biological Imaging, TranslaTUM, Technical University of Munich, Ismaningerstr. 22, Munich 81675, Germany.
| | - Miguel A Pleitez
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg 85764, Germany; Chair of Biological Imaging, TranslaTUM, Technical University of Munich, Ismaningerstr. 22, Munich 81675, Germany
| | - Silvio Aime
- Molecular Imaging Center, Department of Molecular Biotechnologies and Health Sciences, University of Turin, Turin 10126, Italy
| | - Kevin M Brindle
- Department of Biochemistry, University of Cambridge, Old Addenbrooke's Site, Cambridge CB2 1GA, UK; Cancer Research UK Cambridge Institute, University of Cambridge, Li Ka Shing Centre, Robinson Way, Cambridge CB2 0RE, UK
| |
Collapse
|
16
|
Wahsner J, Gale EM, Rodríguez-Rodríguez A, Caravan P. Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers. Chem Rev 2019; 119:957-1057. [PMID: 30350585 PMCID: PMC6516866 DOI: 10.1021/acs.chemrev.8b00363] [Citation(s) in RCA: 828] [Impact Index Per Article: 165.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Tens of millions of contrast-enhanced magnetic resonance imaging (MRI) exams are performed annually around the world. The contrast agents, which improve diagnostic accuracy, are almost exclusively small, hydrophilic gadolinium(III) based chelates. In recent years concerns have arisen surrounding the long-term safety of these compounds, and this has spurred research into alternatives. There has also been a push to develop new molecularly targeted contrast agents or agents that can sense pathological changes in the local environment. This comprehensive review describes the state of the art of clinically approved contrast agents, their mechanism of action, and factors influencing their safety. From there we describe different mechanisms of generating MR image contrast such as relaxation, chemical exchange saturation transfer, and direct detection and the types of molecules that are effective for these purposes. Next we describe efforts to make safer contrast agents either by increasing relaxivity, increasing resistance to metal ion release, or by moving to gadolinium(III)-free alternatives. Finally we survey approaches to make contrast agents more specific for pathology either by direct biochemical targeting or by the design of responsive or activatable contrast agents.
Collapse
Affiliation(s)
- Jessica Wahsner
- Athinoula A. Martinos Center for Biomedical Imaging and the Institute for Innovation in Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA
| | - Eric M. Gale
- Athinoula A. Martinos Center for Biomedical Imaging and the Institute for Innovation in Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA
| | - Aurora Rodríguez-Rodríguez
- Athinoula A. Martinos Center for Biomedical Imaging and the Institute for Innovation in Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA
| | - Peter Caravan
- Athinoula A. Martinos Center for Biomedical Imaging and the Institute for Innovation in Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA
| |
Collapse
|
17
|
Sinharay S, Randtke EA, Howison CM, Ignatenko NA, Pagel MD. Detection of Enzyme Activity and Inhibition during Studies in Solution, In Vitro and In Vivo with CatalyCEST MRI. Mol Imaging Biol 2019; 20:240-248. [PMID: 28726131 DOI: 10.1007/s11307-017-1092-8] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
PURPOSE The detection of enzyme activities and evaluation of enzyme inhibitors have been challenging with magnetic resonance imaging (MRI). To address this need, we have developed a diamagnetic, nonmetallic contrast agent and a protocol known as catalyCEST MRI that uses chemical exchange saturation transfer (CEST) to detect enzyme activity as well as enzyme inhibition. PROCEDURES We synthesized a diamagnetic MRI contrast agent that has enzyme responsive and enzyme unresponsive CEST signals. We tested the ability of this agent to detect the activity of kallikrein 6 (KLK6) in biochemical solutions, in vitro and in vivo, with and without a KLK6 inhibitor. RESULTS The agent detected KLK6 activity in solution and also detected KLK6 inhibition by antithrombin III. KLK6 activity was detected during in vitro studies with HCT116 colon cancer cells, relative to the detection of almost no activity in a KLK6-knockdown HCT116 cell line and HCT116 cells treated with antithrombin III inhibitor. Finally, strong enzyme activity was detected within an in vivo HCT116 tumor model, while lower enzyme activity was detected in a KLK6 knockdown tumor model and in the HCT116 tumor model treated with antithrombin III inhibitor. In all cases, comparisons of the enzyme responsive and enzyme unresponsive CEST signals were critical for the detection of enzyme activity. CONCLUSIONS This study has established that catalyCEST MRI with an exogenous diaCEST agent can evaluate enzyme activity and inhibition in solution, in vitro and in vivo.
Collapse
Affiliation(s)
- Sanhita Sinharay
- Department of Chemistry and Biochemistry, University of Arizona, Tucson, AZ, USA
| | - Edward A Randtke
- Department of Medical Imaging, University of Arizona, 1515 N. Campbell Avenue, Tucson, AZ, 84724-5024, USA
| | - Christine M Howison
- Department of Medical Imaging, University of Arizona, 1515 N. Campbell Avenue, Tucson, AZ, 84724-5024, USA
| | - Natalia A Ignatenko
- Department of Cellular and Molecular Medicine, University of Arizona, Tucson, AZ, USA.,University of Arizona Cancer Center, University of Arizona, Tucson, AZ, USA
| | - Mark D Pagel
- Department of Chemistry and Biochemistry, University of Arizona, Tucson, AZ, USA. .,Department of Medical Imaging, University of Arizona, 1515 N. Campbell Avenue, Tucson, AZ, 84724-5024, USA. .,University of Arizona Cancer Center, University of Arizona, Tucson, AZ, USA. .,Department of Cancer Systems Imaging, MD Anderson Cancer Center, 1881 East Road, Houston, TX, 77054, USA.
| |
Collapse
|
18
|
Zhang J, Han Z, Lu J, Li Y, Liao X, van Zijl PC, Yang X, Liu G. Triazoles as T 2 -Exchange Magnetic Resonance Imaging Contrast Agents for the Detection of Nitrilase Activity. Chemistry 2018; 24:15013-15018. [PMID: 29989227 DOI: 10.1002/chem.201802663] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2018] [Indexed: 02/04/2023]
Abstract
We characterized the T2 -exchange (T2ex ) magnetic resonance imaging (MRI) contrast of azole protons that have large chemical shifts from the water proton resonance as a function of pH, temperature, and chemical modification. Our results showed that 1,2,4-triazoles could be tuned into excellent diamagnetic T2ex contrast agents, with an optimal exchange-based relaxivity r2ex of 0.10 s-1 mm-1 at physiological pH and B0 =9.4 T. A fit of r2ex data to the Swift-Connick equation indicated that imino proton exchange of triazoles is dominated by a base-catalyzed process at higher pH values and an acid-catalyzed process at lower pH. The magnitude of r2ex was also found to be heavily dependent on chemical modifications, that is, enhanced by electron-donating groups, such as amines and methyls, or by intramolecular hydrogen bonding between the imino proton and the carboxyl, and weakened by electron-withdrawing groups like bromo, cyano, and nitro. In light of these findings, we applied T2ex MRI to assess the activity of nitrilase, an enzyme catalyzing the hydrolysis of 1,2,4-triazole-3-carbonitrile to 1,2,4-triazole-3-carboxylic acid, resulting in the enhancement of R2ex . Our findings suggest that 1,2,4-triazoles have potential to provide sensitive and tunable diagnostic probes for MRI.
Collapse
Affiliation(s)
- Jia Zhang
- The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Zheng Han
- The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Jiaqi Lu
- Department of Chemical and Biomolecular Engineering, Johns Hopkins University, Baltimore, Maryland, USA
| | - Yuguo Li
- The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Xuhe Liao
- Department of Nuclear Medicine, Peking University First Hospital, Beijing, P. R. China
| | - Peter C van Zijl
- The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
| | - Xing Yang
- Department of Nuclear Medicine, Peking University First Hospital, Beijing, P. R. China
| | - Guanshu Liu
- The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
| |
Collapse
|
19
|
Dastrù W, Menchise V, Ferrauto G, Fabretto S, Carrera C, Terreno E, Aime S, Castelli DD. Modulation of the Prototropic Exchange Rate in pH-Responsive Yb-HPDO3A Derivatives as ParaCEST Agents. ChemistrySelect 2018. [DOI: 10.1002/slct.201800283] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Walter Dastrù
- Department of Molecular Biotechnology and Health Sciences; Molecular Imaging Center; University of Torino; Via Nizza 52 10126 Torino Italy
| | - Valeria Menchise
- Istituto di Biostrutture e Bioimmagini; Consiglio Nazionale delle Ricerche; via Mezzocannone 16 80134 Napoli Italy
| | - Giuseppe Ferrauto
- Department of Molecular Biotechnology and Health Sciences; Molecular Imaging Center; University of Torino; Via Nizza 52 10126 Torino Italy
| | - Serena Fabretto
- Department of Molecular Biotechnology and Health Sciences; Molecular Imaging Center; University of Torino; Via Nizza 52 10126 Torino Italy
| | - Carla Carrera
- Department of Molecular Biotechnology and Health Sciences; Molecular Imaging Center; University of Torino; Via Nizza 52 10126 Torino Italy
| | - Enzo Terreno
- Department of Molecular Biotechnology and Health Sciences; Molecular Imaging Center; University of Torino; Via Nizza 52 10126 Torino Italy
| | - Silvio Aime
- Department of Molecular Biotechnology and Health Sciences; Molecular Imaging Center; University of Torino; Via Nizza 52 10126 Torino Italy
| | - Daniela Delli Castelli
- Department of Molecular Biotechnology and Health Sciences; Molecular Imaging Center; University of Torino; Via Nizza 52 10126 Torino Italy
| |
Collapse
|
20
|
Dang T, Suchy M, Truong YJ, Oakden W, Lam WW, Lazurko C, Facey G, Stanisz GJ, Shuhendler AJ. Hydrazo-CEST: Hydrazone-Dependent Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Contrast Agents. Chemistry 2018; 24:9148-9156. [PMID: 29645309 DOI: 10.1002/chem.201801671] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2018] [Indexed: 11/06/2022]
Abstract
The rapid formation of hydrazones under physiological conditions was exploited for the detection of aldehydes through chemical exchange saturation transfer magnetic resonance imaging (CEST-MRI). A metal-free, diamagnetic contrast agent derived from N-amino anthranilic acid was introduced, which selectively "turned-on" upon hydrazone formation through an effect termed Hydrazo-CEST. While the hydrazine form of the probe produced no CEST-MRI signal enhancement, the formation of the aryl hydrazone resulted in >20 % intensity decrease in the bulk water signal through the CEST effect, as measured by 300 MHz 1 H NMR, 3 T and 7 T MRI. Both the electronic contributions of the N-amino anthranilate and the aldehyde binding partner were shown to directly impact the exchange rate of the proton on the ring-proximal nitrogen, and thus the imaging signal. Additionally, the presence of the carboxylic acid moiety ortho to the hydrazine was necessary not only for contrast production, but also for rapid hydrazone formation and prolonged hydrazone product stability under physiological conditions. This work provided the first example of an MRI-based contrast agent capable of a "turn on" response upon reaction with bioactive aldehydes, and outlined both the structural and electronic requirements to expand on Hydrazo-CEST, a novel, hydrazone-dependent subtype of diamagnetic CEST-MRI.
Collapse
Affiliation(s)
- Trina Dang
- Department of Chemistry & Biomolecular Sciences, University of Ottawa, Ottawa, ON, Canada
| | - Mojmír Suchy
- Department of Chemistry & Biomolecular Sciences, University of Ottawa, Ottawa, ON, Canada.,University of Ottawa Heart Institute, Ottawa, ON, Canada
| | - Yen J Truong
- Department of Chemistry & Biomolecular Sciences, University of Ottawa, Ottawa, ON, Canada
| | - Wendy Oakden
- Department of Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada
| | - Wilfred W Lam
- Department of Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada
| | - Caitlin Lazurko
- Department of Chemistry & Biomolecular Sciences, University of Ottawa, Ottawa, ON, Canada
| | - Glenn Facey
- Department of Chemistry & Biomolecular Sciences, University of Ottawa, Ottawa, ON, Canada
| | - Greg J Stanisz
- Department of Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada.,Department of Biomedical Physics, University of Toronto, Toronto, ON, Canada.,Department of Neurosurgery and Pediatric Neurosurgery, Medical University, Lublin, Poland
| | - Adam J Shuhendler
- Department of Chemistry & Biomolecular Sciences, University of Ottawa, Ottawa, ON, Canada.,University of Ottawa Heart Institute, Ottawa, ON, Canada
| |
Collapse
|
21
|
Banerjee SR, Song X, Yang X, Minn I, Lisok A, Chen Y, Bui A, Chatterjee S, Chen J, van Zijl PCM, McMahon MT, Pomper MG. Salicylic Acid-Based Polymeric Contrast Agents for Molecular Magnetic Resonance Imaging of Prostate Cancer. Chemistry 2018; 24:7235-7242. [PMID: 29508450 PMCID: PMC5980787 DOI: 10.1002/chem.201800882] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Indexed: 01/31/2023]
Abstract
Chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) is an innovative molecular imaging technique in which contrast agents are labeled by saturating their exchangeable proton spins by radio-frequency irradiation. Salicylic acid and its analogues are a promising class of highly sensitive, diamagnetic CEST agents. Herein, polymeric agents grafted with salicylic acid moieties and a known high-affinity ligand targeting prostate-specific membrane antigen in approximately 10:1 molar ratio were synthesized to provide sufficient MRI sensitivity and receptor specificity. The proton-exchange properties of the contrast agent in solution and in an experimental murine model are reported to demonstrate the feasibility of receptor-targeted CEST MRI of prostate cancer. Furthermore, the CEST imaging data were validated with an 111 In-labeled analogue of the agent by in vivo single photon emission computed tomographic imaging and tissue biodistribution studies.
Collapse
Affiliation(s)
- Sangeeta Ray Banerjee
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA, 21287
| | - Xiaolei Song
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA, 21287
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
| | - Xing Yang
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA, 21287
| | - Il Minn
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA, 21287
| | - Ala Lisok
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA, 21287
| | - Yanrong Chen
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
| | - Albert Bui
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA, 21287
| | - Samit Chatterjee
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA, 21287
| | - Jian Chen
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA, 21287
| | - Peter C. M. van Zijl
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA, 21287
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
| | - Michael T. McMahon
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA, 21287
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
| | - Martin G. Pomper
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA, 21287
| |
Collapse
|
22
|
Lindeman LR, Randtke EA, High RA, Jones KM, Howison CM, Pagel MD. A comparison of exogenous and endogenous CEST MRI methods for evaluating in vivo pH. Magn Reson Med 2018; 79:2766-2772. [PMID: 29024066 PMCID: PMC5821269 DOI: 10.1002/mrm.26924] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2017] [Revised: 08/24/2017] [Accepted: 08/27/2017] [Indexed: 12/24/2022]
Abstract
PURPOSE Extracellular pH (pHe) is an important biomarker for cancer cell metabolism. Acido-chemical exchange saturation transfer (CEST) MRI uses the contrast agent iopamidol to create spatial maps of pHe. Measurements of amide proton transfer exchange rates (kex ) from endogenous CEST MRI were compared to pHe measurements by exogenous acido-CEST MRI to determine whether endogenous kex could be used as a proxy for pHe measurements. METHODS Spatial maps of pHe and kex were obtained using exogenous acidoCEST MRI and an endogenous CEST MRI analyzed with the omega plot method, respectively, to evaluate mouse kidney, a flank tumor model, and a spontaneous lung tumor model. The pHe and kex results were evaluated using pixelwise comparisons. RESULTS The kex values obtained from endogenous CEST measurements did not correlate with the pHe results from exogenous CEST measurements. The kex measurements were limited to fewer pixels and had a limited dynamic range relative to pHe measurements. CONCLUSION Measurements of kex with endogenous CEST MRI cannot substitute for pHe measurements with acidoCEST MRI. Whereas endogenous CEST MRI may still have good utility for evaluating some specific pathologies, exogenous acido-CEST MRI is more appropriate when evaluating pathologies based on pHe values. Magn Reson Med 79:2766-2772, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Leila R. Lindeman
- Cancer Biology Graduate Interdisciplinary Program, University of Arizona Cancer Center, Tucson, AZ, USA
| | - Edward A. Randtke
- Department of Medical Imaging, University of Arizona, Tucson, AZ, USA
| | - Rachel A. High
- Cancer Biology Graduate Interdisciplinary Program, University of Arizona Cancer Center, Tucson, AZ, USA
| | - Kyle M. Jones
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, USA
| | | | - Mark D. Pagel
- Cancer Biology Graduate Interdisciplinary Program, University of Arizona Cancer Center, Tucson, AZ, USA
- Department of Medical Imaging, University of Arizona, Tucson, AZ, USA
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, USA
| |
Collapse
|
23
|
McMahon MT, Bulte JWM. Two decades of dendrimers as versatile MRI agents: a tale with and without metals. WILEY INTERDISCIPLINARY REVIEWS. NANOMEDICINE AND NANOBIOTECHNOLOGY 2018; 10:e1496. [PMID: 28895298 PMCID: PMC5989322 DOI: 10.1002/wnan.1496] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2017] [Revised: 07/25/2017] [Accepted: 08/02/2017] [Indexed: 12/24/2022]
Abstract
Dendrimers or dendritic polymers are a class of compounds with great potential for nanomedical use. Some of their properties, including their rigidity, low polydispersity and the ease with which their surfaces can be modified make them particularly well suited for use as MRI diagnostic or theranostic agents. For the past 20 years, researchers have recognized this potential and refined dendrimer formulations to optimize these nanocarriers for a host of MRI applications, including blood pool imaging agents, lymph node imaging agents, tumor-targeted theranostic agents and cell tracking agents. This review summarizes the various types of dendrimers according to the type of MR contrast they can provide. This includes the metallic T1 , T2 and paraCEST imaging agents, and the non-metallic diaCEST and fluorinated (19 F) heteronuclear imaging agents. This article is categorized under: Diagnostic Tools > In Vivo Nanodiagnostics and Imaging Implantable Materials and Surgical Technologies > Nanomaterials and Implants.
Collapse
Affiliation(s)
- Michael T. McMahon
- The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Jeff W. M. Bulte
- The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
- Cellular Imaging Section and Vascular Biology Program, Institute for Cell Engineering, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
- Department of Biomedical Engineering, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
- Department of Oncology, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
- Department of Chemical & Biomolecular Engineering, The Johns Hopkins University Whiting School of Engineering, Baltimore, MD, USA
| |
Collapse
|
24
|
Jones KM, Randtke EA, Yoshimaru ES, Howison CM, Chalasani P, Klein RR, Chambers SK, Kuo PH, Pagel MD. Clinical Translation of Tumor Acidosis Measurements with AcidoCEST MRI. Mol Imaging Biol 2018; 19:617-625. [PMID: 27896628 DOI: 10.1007/s11307-016-1029-7] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
PURPOSE We optimized acido-chemical exchange saturation transfer (acidoCEST) magnetic resonance imaging (MRI), a method that measures extracellular pH (pHe), and translated this method to the radiology clinic to evaluate tumor acidosis. PROCEDURES A CEST-FISP MRI protocol was used to image a flank SKOV3 tumor model. Bloch fitting modified to include the direct estimation of pH was developed to generate parametric maps of tumor pHe in the SKOV3 tumor model, a patient with high-grade invasive ductal carcinoma, and a patient with metastatic ovarian cancer. The acidoCEST MRI results of the patient with metastatic ovarian cancer were compared with DCE MRI and histopathology. RESULTS The pHe maps of a flank model showed pHe measurements between 6.4 and 7.4, which matched with the expected tumor pHe range from past acidoCEST MRI studies in flank tumors. In the patient with metastatic ovarian cancer, the average pHe value of three adjacent tumors was 6.58, and the most reliable pHe measurements were obtained from the right posterior tumor, which favorably compared with DCE MRI and histopathological results. The average pHe of the kidney showed an average pHe of 6.73 units. The patient with high-grade invasive ductal carcinoma failed to accumulate sufficient agent to generate pHe measurements. CONCLUSIONS Optimized acidoCEST MRI generated pHe measurements in a flank tumor model and could be translated to the clinic to assess a patient with metastatic ovarian cancer.
Collapse
Affiliation(s)
- Kyle M Jones
- Biomedical Engineering Graduate Interdisciplinary Program, University of Arizona, Tucson, AZ, USA
| | - Edward A Randtke
- Department of Medical Imaging, University of Arizona, 1515 N. Campbell Ave., Tucson, AZ, 85724-5024, USA
| | | | - Christine M Howison
- Department of Medical Imaging, University of Arizona, 1515 N. Campbell Ave., Tucson, AZ, 85724-5024, USA
| | - Pavani Chalasani
- Division of Hematology-Oncology, University of Arizona, Tucson, AZ, USA
| | - Robert R Klein
- Department of Pathology, University of Arizona, Tucson, AZ, USA
| | - Setsuko K Chambers
- University of Arizona Cancer Center, Tucson, AZ, USA.,Department of Obstetrics and Gynecology, University of Arizona, Tucson, AZ, USA
| | - Phillip H Kuo
- Biomedical Engineering Graduate Interdisciplinary Program, University of Arizona, Tucson, AZ, USA.,Department of Medical Imaging, University of Arizona, 1515 N. Campbell Ave., Tucson, AZ, 85724-5024, USA.,University of Arizona Cancer Center, Tucson, AZ, USA
| | - Mark D Pagel
- Biomedical Engineering Graduate Interdisciplinary Program, University of Arizona, Tucson, AZ, USA. .,Department of Medical Imaging, University of Arizona, 1515 N. Campbell Ave., Tucson, AZ, 85724-5024, USA. .,University of Arizona Cancer Center, Tucson, AZ, USA.
| |
Collapse
|
25
|
Dual Contrast - Magnetic Resonance Fingerprinting (DC-MRF): A Platform for Simultaneous Quantification of Multiple MRI Contrast Agents. Sci Rep 2017; 7:8431. [PMID: 28814732 PMCID: PMC5559598 DOI: 10.1038/s41598-017-08762-9] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2017] [Accepted: 07/12/2017] [Indexed: 01/21/2023] Open
Abstract
Injectable Magnetic Resonance Imaging (MRI) contrast agents have been widely used to provide critical assessments of disease for both clinical and basic science imaging research studies. The scope of available MRI contrast agents has expanded over the years with the emergence of molecular imaging contrast agents specifically targeted to biological markers. Unfortunately, synergistic application of more than a single molecular contrast agent has been limited by MRI's ability to only dynamically measure a single agent at a time. In this study, a new Dual Contrast - Magnetic Resonance Fingerprinting (DC - MRF) methodology is described that can detect and independently quantify the local concentration of multiple MRI contrast agents following simultaneous administration. This "multi-color" MRI methodology provides the opportunity to monitor multiple molecular species simultaneously and provides a practical, quantitative imaging framework for the eventual clinical translation of molecular imaging contrast agents.
Collapse
|
26
|
Jones KM, Pollard AC, Pagel MD. Clinical applications of chemical exchange saturation transfer (CEST) MRI. J Magn Reson Imaging 2017; 47:11-27. [PMID: 28792646 DOI: 10.1002/jmri.25838] [Citation(s) in RCA: 184] [Impact Index Per Article: 26.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2017] [Accepted: 05/30/2017] [Indexed: 02/06/2023] Open
Abstract
Chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) has been developed and employed in multiple clinical imaging research centers worldwide. Selective radiofrequency (RF) saturation pulses with standard 2D and 3D MRI acquisition schemes are now routinely performed, and CEST MRI can produce semiquantitative results using magnetization transfer ratio asymmetry (MTRasym ) analysis while accounting for B0 inhomogeneity. Faster clinical CEST MRI acquisition methods and more quantitative acquisition and analysis routines are under development. Endogenous biomolecules with amide, amine, and hydroxyl groups have been detected during clinical CEST MRI studies, and exogenous CEST agents have also been administered to patients. These CEST MRI tools show promise for contributing to assessments of cerebral ischemia, neurological disorders, lymphedema, osteoarthritis, muscle physiology, and solid tumors. This review summarizes the salient features of clinical CEST MRI protocols and critically evaluates the utility of CEST MRI for these clinical imaging applications. LEVEL OF EVIDENCE 5 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:11-27.
Collapse
Affiliation(s)
- Kyle M Jones
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona, USA
| | | | - Mark D Pagel
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona, USA.,Department of Chemistry, Rice University, Houston, Texas, USA.,Department of Cancer Systems Imaging, MD Anderson Cancer Center, Houston, Texas, USA
| |
Collapse
|
27
|
Singh J, Rustagi V, Zhang S, Sherry AD, Udugamasooriya DG. On-bead combinatorial synthesis and imaging of europium(III)-based paraCEST agents aids in identification of chemical features that enhance CEST sensitivity. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2017; 55:747-753. [PMID: 28220538 PMCID: PMC5501467 DOI: 10.1002/mrc.4588] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2016] [Revised: 02/15/2017] [Accepted: 02/16/2017] [Indexed: 05/08/2023]
Abstract
The rate of water exchange between the inner sphere of a paramagnetic ion and bulk water is an important parameter in determining the magnitude of the chemical exchange saturation transfer signal from paramagnetic CEST agents (paraCEST). This is governed by various geometric, steric and ligand field factors created by macrocyclic ligands surrounding the paramagnetic metal ion. Our previous on-bead combinatorial studies of di-peptoid-europium(III)-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA)-tetraamide complexes revealed that negatively charged groups in the immediate vicinity of the metal center strongly enhances the CEST signal. Here, we report a solid phase synthesis and on-bead imaging of 76 new DOTA derivatives that are developed by coupling with a single residue onto each of the three arms of a DOTA-tetraamide scaffold attached to resin beads. This single residue predominantly carries negatively charged groups blended with various physico-chemical characteristics. We found that non-bulky negatively charged groups are best suited at the immediate vicinity of the metal ion, while positive, bulky and halogen containing moieties suppress the CEST signal. Copyright © 2017 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Jaspal Singh
- Department of Pharmacological and Pharmaceutical Sciences, University of Houston, 3455 Cullen Blvd, Houston, TX, 77204-5037, USA
| | - Vineeta Rustagi
- Department of Pharmacological and Pharmaceutical Sciences, University of Houston, 3455 Cullen Blvd, Houston, TX, 77204-5037, USA
| | - Shanrong Zhang
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX, 75390-8568, USA
| | - A Dean Sherry
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX, 75390-8568, USA
- Department of Chemistry, University of Texas at Dallas, 800 West Campbell Rd, Richardson, TX, 75083-3021, USA
| | - D Gomika Udugamasooriya
- Department of Pharmacological and Pharmaceutical Sciences, University of Houston, 3455 Cullen Blvd, Houston, TX, 77204-5037, USA
- Department of Cancer Systems Imaging, MD Anderson Cancer Center, 1881 East Road, Houston, TX, 77030-4009, USA
| |
Collapse
|
28
|
Sinharay S, Howison CM, Baker AF, Pagel MD. Detecting in vivo urokinase plasminogen activator activity with a catalyCEST MRI contrast agent. NMR IN BIOMEDICINE 2017; 30:10.1002/nbm.3721. [PMID: 28370884 PMCID: PMC5704996 DOI: 10.1002/nbm.3721] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2016] [Revised: 02/04/2017] [Accepted: 02/06/2017] [Indexed: 05/22/2023]
Abstract
Urokinase plasminogen activator (uPA) promotes tumor invasion and metastasis. The monitoring of uPA activity using molecular imaging may have prognostic value and be predictive for response to anti-cancer therapies. However, the detection of in vivo enzyme activity with molecular imaging remains a challenge. To address this problem, we designed a nonmetallic contrast agent, GR-4Am-SA, that can be detected with chemical exchange saturation transfer (CEST) MRI. This agent has a peptide that is cleaved by uPA, which causes a CEST signal at 5.0 ppm to decrease, and also has a salicylic acid moiety that can produce a CEST signal at 9.5 ppm, which is largely unresponsive to enzyme activity. The two CEST signals were used to determine a reaction coordinate, representing the extent of enzyme-catalyzed cleavage of the GR-4Am-SA agent during an experimental study. Initial biochemical studies showed that GR-4Am-SA could detect uPA activity in reducing conditions. Subsequently, we used our catalyCEST MRI protocol with the agent to detect the uPA catalysis of GR-4Am-SA in a flank xenograft model of Capan-2 pancreatic cancer. The results showed an average reaction coordinate of 80% ± 8%, which was strongly dependent on the CEST signal at 5.0 ppm. The relative independence of the reaction coordinate on the CEST signal at 9.5 ppm showed that the detection of enzyme activity was largely independent of the concentration of GR-4Am-SA within the tumor tissue. These results demonstrated the advantages of a single CEST agent with biomarker-responsive and unresponsive signals for reliably assessing enzyme activity during in vivo cancer studies.
Collapse
Affiliation(s)
- Sanhita Sinharay
- Department of Chemistry and Biochemistry, University of Arizona, Tucson, AZ
| | | | - Amanda F. Baker
- University of Arizona Cancer Center, University of Arizona, Tucson, AZ
| | - Mark D. Pagel
- Department of Chemistry and Biochemistry, University of Arizona, Tucson, AZ
- University of Arizona Cancer Center, University of Arizona, Tucson, AZ
- Department of Medical Imaging, University of Arizona, Tucson, AZ
- Corresponding Author: Mark D. Pagel, University of Arizona Cancer Center, 1515 N. Campbell Avenue, Tucson, AZ 85724-5024, Tel: (520)-404-7049, Fax: (520)-626-0395,
| |
Collapse
|
29
|
Diamagnetic Imaging Agents with a Modular Chemical Design for Quantitative Detection of β-Galactosidase and β-Glucuronidase Activities with CatalyCEST MRI. Bioconjug Chem 2016; 27:2549-2557. [PMID: 27657647 PMCID: PMC6013409 DOI: 10.1021/acs.bioconjchem.6b00482] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Imaging agents for the noninvasive in vivo detection of enzyme activity in preclinical and clinical settings could have fundamental implications in the field of drug discovery. Furthermore, a new class of targeted prodrug treatments takes advantage of high enzyme activity to tailor therapy and improve treatment outcomes. Herein, we report the design and synthesis of new magnetic resonance imaging (MRI) agents that quantitatively detect β-galactosidase and β-glucuronidase activities by measuring changes in chemical exchange saturation transfer (CEST). Based on a modular approach, we incorporated the enzymes' respective substrates to a salicylate moiety with a chromogenic spacer via a carbamate linkage. This furnished highly selective diamagnetic CEST agents that detected and quantified enzyme activities of glycoside hydrolase enzymes. Michaelis-Menten enzyme kinetics studies were performed by monitoring catalyCEST MRI signals, which were validated with UV-vis assays.
Collapse
|
30
|
Daryaei I, Mohammadebrahim Ghaffari M, Jones KM, Pagel MD. Detection of Alkaline Phosphatase Enzyme Activity with a CatalyCEST MRI Biosensor. ACS Sens 2016; 1:857-861. [PMID: 30246144 DOI: 10.1021/acssensors.6b00203] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Responsive CEST MRI biosensors offer good sensitivity and excellent specificity for detection of biomarkers with great potential for clinical translation. We report the application of fosfosal, a phosphorylated form of salicylic acid, for the detection of alkaline phosphatase (AP) enzyme. We detected conversion of fosfosal to salicylic acid in the presence of the enzyme by CEST MRI. Importantly the technique was able to detect AP enzyme expressed in cells in the presence of other cell components, which improves specificity. Various isoforms of the enzyme showed different Michaelis-Menten kinetics and yet these kinetics studies indicated very efficient catalytic rates. Our results with the fosfosal biosensor encourage further in vivo studies.
Collapse
Affiliation(s)
- Iman Daryaei
- Biological
Chemistry Program, Department of Chemistry and Biochemistry, University of Arizona, Tucson, Arizona 85719, United States
| | - Mahsa Mohammadebrahim Ghaffari
- Biological
Chemistry Program, Department of Chemistry and Biochemistry, University of Arizona, Tucson, Arizona 85719, United States
| | - Kyle M. Jones
- Department
of Biomedical Engineering, University of Arizona, Tucson, Arizona 85721, United States
| | - Mark D. Pagel
- University of Arizona Cancer Center, Tucson, Arizona 85724, United States
- Department
of Medical Imaging, University of Arizona, Tucson, Arizona 85724, United States
| |
Collapse
|
31
|
Sinharay S, Randtke EA, Jones KM, Howison CM, Chambers SK, Kobayashi H, Pagel MD. Noninvasive detection of enzyme activity in tumor models of human ovarian cancer using catalyCEST MRI. Magn Reson Med 2016; 77:2005-2014. [PMID: 27221386 DOI: 10.1002/mrm.26278] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2016] [Revised: 04/25/2016] [Accepted: 04/25/2016] [Indexed: 12/17/2022]
Abstract
PURPOSE We proposed to detect the in vivo enzyme activity of γ-glutamyl transferase (GGT) within mouse models of human ovarian cancers using catalyCEST MRI with a diamagnetic CEST agent. METHODS A CEST-FISP MRI protocol and a diamagnetic CEST agent were developed to detect GGT enzyme activity in biochemical solution. A quantitative Michaelis-Menten enzyme kinetics study was performed to confirm that catalyCEST MRI can measure enzyme activity. In vivo catalyCEST MRI studies generated pixel-wise activity maps of GGT activities. Ex vivo fluorescence imaging was performed for validation. RESULTS CatalyCEST MRI selectively detected two CEST signals from a single CEST agent, whereby one CEST signal was responsive to GGT enzyme activity and the other CEST signal was an unresponsive control signal. The comparison of these CEST signals facilitated in vivo catalyCEST MRI studies that detected high GGT activity in OVCAR-8 tumors, low GGT activity in OVCAR-3 tumors, and low or no GGT activity in muscle tissues. CONCLUSION CatalyCEST MRI with a diamagnetic CEST agent can detect the level of GGT enzyme activity within in vivo tumor models of human ovarian cancers. Magn Reson Med 77:2005-2014, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Sanhita Sinharay
- Department of Chemistry and Biochemistry, University of Arizona, Tucson, Arizona, USA
| | - Edward A Randtke
- Department of Medical Imaging, University of Arizona, Tucson, Arizona, USA
| | - Kyle M Jones
- Biomedical Engineering Graduate Interdisciplinary Program, University of Arizona, Tucson, Arizona, USA
| | | | - Setsuko K Chambers
- Department of Obstetrics and Gynecology, University of Arizona, Tucson, Arizona, USA.,University of Arizona Cancer Center, University of Arizona, Tucson, Arizona, USA
| | - Hisataka Kobayashi
- Laboratory of Molecular Theranostics, National Cancer Institute, NIH, Bethesda, Maryland, USA
| | - Mark D Pagel
- Department of Chemistry and Biochemistry, University of Arizona, Tucson, Arizona, USA.,Department of Medical Imaging, University of Arizona, Tucson, Arizona, USA.,University of Arizona Cancer Center, University of Arizona, Tucson, Arizona, USA
| |
Collapse
|
32
|
Fernández-Cuervo G, Sinharay S, Pagel MD. A CatalyCEST MRI Contrast Agent that Can Simultaneously Detect Two Enzyme Activities. Chembiochem 2016; 17:383-7. [PMID: 26693680 PMCID: PMC4814164 DOI: 10.1002/cbic.201500586] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2015] [Indexed: 12/28/2022]
Abstract
The simultaneous detection of multiple enzyme activities can improve the specificity of disease diagnoses. We therefore synthesized and characterized a diamagnetic chemical exchange saturation transfer (CEST) MRI contrast agent that can simultaneously detect two enzyme activities. Sulfatase and esterase enzymes cleave the ligands of the CEST agent, releasing salicylic acid that can be detected with CEST MRI. Importantly, both enzymes are required to activate the agent to produce a CEST MRI contrast, and the CEST agent was stable without enzyme treatment. These results established that this diamagnetic CEST MRI contrast agent is a platform technology with a modular design that can be potentially exploited to detect other combinations of enzyme activities, which can expand the armamentarium of contrast agents for molecular imaging.
Collapse
Affiliation(s)
- Gabriela Fernández-Cuervo
- Department of Pharmaceutical Sciences, University of Arizona, 1515 N. Campbell Ave., Tucson, AZ, 85724, USA
| | - Sanhita Sinharay
- Department of Chemistry and Biochemistry, University of Arizona, 1515 N. Campbell Ave., Tucson, AZ, 85724, USA
| | - Mark D Pagel
- Department of Medical Imaging, University of Arizona, 1515 N. Campbell Ave., Tucson, AZ, 85724, USA.
| |
Collapse
|