Jacobs PS, Benyard B, Cember A, Nanga RPR, Cao Q, Tisdall MD, Wilson N, Das S, Davis KA, Detre J, Roalf D, Reddy R. Repeatability of B 1 + inhomogeneity correction of volumetric (3D) glutamate CEST via High-permittivity dielectric padding at 7T. Magn Reson Med 2022; 88:2475-2484. [PMID: 36178233 PMCID: PMC9529237 DOI: 10.1002/mrm.29409] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 07/18/2022] [Accepted: 07/19/2022] [Indexed: 12/03/2023]
Abstract
PURPOSE Ultra-high field MR imaging lacks B1 + inhomogeneity due to shorter RF wavelengths used at higher field strengths compared to human anatomy. CEST techniques tend to be highly susceptible to B1 + inhomogeneities due to a high and uniform B1 + field being necessary to create the endogenous contrast. High-permittivity dielectric pads have seen increasing usage in MR imaging due to their ability to tailor the spatial distribution of the B1 + field produced. The purpose of this work is to demonstrate that dielectric materials can be used to improve glutamate weighted CEST (gluCEST) at 7T. THEORY AND METHODS GluCEST images were acquired on a 7T system on six healthy volunteers. Aqueous calcium titanate pads, with a permittivity of approximately 110, were placed on either side in the subject's head near the temporal lobes. A post-processing correction algorithm was implemented in combination with dielectric padding to compare contrast improvement. Tissue segmentation was performed to assess the effect of dielectric pads on gray and white matter separately. RESULTS GluCEST images demonstrated contrast enhancement in the lateral temporal lobe regions with dielectric pad placement. Tissue segmentation analysis showed an increase in correction effectiveness within the gray matter tissue compared to white matter tissue. Statistical testing suggested a significant difference in gluCEST contrast when pads were used and showed a difference in the gray matter tissue segment. CONCLUSION The use of dielectric pads improved the B1 + field homogeneity and enhanced gluCEST contrast for all subjects when compared to data that did not incorporate padding.
Collapse
Affiliation(s)
- Paul S Jacobs
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Blake Benyard
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Abigail Cember
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Ravi Prakash Reddy Nanga
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Quy Cao
- Penn Statistics in Imaging and Visualization Center, Department of Biostatistics, Epidemiology, and Informatics, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - M Dylan Tisdall
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Neil Wilson
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Sandhitsu Das
- Department of Neurology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Kathryn A Davis
- Department of Neurology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - John Detre
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
- Department of Neurology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - David Roalf
- Department of Psychiatry, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Ravinder Reddy
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
2
|
Estimation of the minimum detectable phase change of surface coil for neural current MRI. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2018; 42:83-90. [PMID: 30467773 DOI: 10.1007/s13246-018-0714-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2018] [Accepted: 11/15/2018] [Indexed: 10/27/2022]
Abstract
Neuronal current magnetic resonance imaging (NC-MRI) is a new method in functional imaging of the brain that could cause the alteration in the phase of magnetic resonance signal. The phase variance is defined as the inverse of the signal to noise ratio (SNR). The intrinsic SNR of the MRI signal is characterized by the coil performance. We evaluated the relation between the geometry and the shape of coils in order to find the minimum detectable change in the signal phase and the possibility of direct detection of neuronal activity by MRI. Full wave equations were solved by the finite element method to calculate the SNR for circular, elliptical, and square shape surface coils. The simulation was repeated for Larmor frequencies of 64 MHz and 85.2 MHz and the coil sizes between 1.5 and 7.5 cm. Relative intrinsic signal to noise ratio (rISNR) of coils with a respect to a selected reference coil and a reference point in the sample was estimated. The circular coil had higher rISNR than other shapes. The increase of the strip width in the coils raised the rISNR 5-20%. For typical imaging parameters, rISNR reference was about 66 which led to a minimum detectable change in MRI signal phase of 0.87° (11.4 nT). It may also be reduced up to tenfold in a 1.5 cm circular coil. Detection of subtle phase signal change due to neuronal activity in surface coils needs a large amount of data acquisition and averaging, but it is intrinsically feasible.
Collapse
|
3
|
Meßner NM, Zöllner FG, Kalayciyan R, Schad LR. Pre-clinical functional Magnetic Resonance Imaging Part II: The heart. Z Med Phys 2014; 24:307-22. [PMID: 25023418 DOI: 10.1016/j.zemedi.2014.06.008] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2013] [Revised: 05/09/2014] [Accepted: 06/17/2014] [Indexed: 12/21/2022]
Abstract
One third of all deaths worldwide in 2008 were caused by cardiovascular diseases (CVD), and the incidence of CVD related deaths rises ever more. Thus, improved imaging techniques and modalities are needed for the evaluation of cardiac morphology and function. Cardiac magnetic resonance imaging (CMRI) is a minimally invasive technique that is increasingly important due to its high spatial and temporal resolution, its high soft tissue contrast and its ability of functional and quantitative imaging. It is widely accepted as the gold standard of cardiac functional analysis. In the short period of small animal MRI, remarkable progress has been achieved concerning new, fast imaging schemes as well as purpose-built equipment. Dedicated small animal scanners allow for tapping the full potential of recently developed animal models of cardiac disease. In this paper, we review state-of-the-art cardiac magnetic resonance imaging techniques and applications in small animals at ultra-high fields (UHF).
Collapse
Affiliation(s)
- Nadja M Meßner
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Frank G Zöllner
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
| | - Raffi Kalayciyan
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Lothar R Schad
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| |
Collapse
|
4
|
Constantinides C, Angeli S. Elimination of mutual inductance in NMR phased arrays: the paddle design revisited. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2012; 222:59-67. [PMID: 22820010 DOI: 10.1016/j.jmr.2012.06.005] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2012] [Revised: 06/09/2012] [Accepted: 06/11/2012] [Indexed: 06/01/2023]
Abstract
This study proposes a method to empirically minimize mutual inductance, using passive end-ring circular paddles, with neighboring coil loops placed in a non-overlapped configuration. The proposed concepts are validated through B(1)-field simulations for resonant coils at f(o)=300.5 MHz, having various sizes (3-10 cm), and for paddles with sizes ranging from 16 to 30 mm, and bench tests on constructed 4×4cm(2) two- (1×2) and four-coil loop (2×2) planar arrays. Simulation results yield total mean percentage B(1)-field differences of only 7.03% between the two non-overlapping coil array configurations (paddles vs. no-paddles). Pair-wise comparisons of elicited mean B(1)-field differences from the use of different circular and rectangular paddle sizes, yield values <5.3%. Theoretical calculation of the normalized mutual coupling coefficient in the non-overlapped coil configuration reduces to almost zero with optimally sized-paddles having a radius of approximately 28% the coil's largest dimension. In the absence of paddles, differences in the split of resonance peaks of 9.9 MHz were observed for the two coils in the 1×2 array, which vanished with paddle placement. Single coil responses (unloaded/loaded) without paddles, and responses from array coils with use of optimally-sized paddles yielded quality factor ratios that ranged between 1.1-1.86 and 1.0-1.5, respectively. Phantom and mouse loaded reflection coefficients S(11)/S(22) were -16.7/-16.2dB and -28.2/-16.1 dB, for the two array loops, respectively. Under unloaded conditions and in the absence of paddles, split resonances were observed for the 1×2 array, yielding transmission coefficients of -5.5 to -8.1 dB, reversing to single resonance responses upon paddle placements, with transmission coefficients of -14.4 to -15.6 dB.
Collapse
Affiliation(s)
- Christakis Constantinides
- Department of Mechanical and Manufacturing Engineering, School of Engineering, University of Cyprus, Cyprus.
| | | |
Collapse
|
5
|
Kim KN, Kim YB, Cho ZH. Improvement of a 4-Channel Spiral-Loop RF Coil Array for TMJ MR Imaging at 7T. ACTA ACUST UNITED AC 2012. [DOI: 10.13104/jksmrm.2012.16.2.103] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Kyoung-Nam Kim
- Neuroscience Research Institute, Gachon University, Incheon, Republic of Korea
| | - Young-Bo Kim
- Neuroscience Research Institute, Gachon University, Incheon, Republic of Korea
| | - Zang-Hee Cho
- Neuroscience Research Institute, Gachon University, Incheon, Republic of Korea
| |
Collapse
|