Kaur H, Khurelbaatar T, Mah J, Heo G, Major PW, Romanyk DL. In vitro biomechanics of divot use, and their placement, in orthodontic aligner therapy. Orthod Craniofac Res 2024; 27:527-534. [PMID: 38299945 DOI: 10.1111/ocr.12760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/16/2024] [Indexed: 02/02/2024]
Abstract
INTRODUCTION To evaluate biomechanics of an aligner utilizing divots and the effect of their vertical placement on the right maxillary central incisor. METHODS An in vitro Orthodontic SIMulator (OSIM) was used to test forces and moments generated by aligners incorporating divots. The OSIM arch was scanned to generate a. STL version that was modified to create four models by placing divots on different positions of the right central maxillary incisor: GI - divots on gingival-third of lingual surface and incisal-third of labial surface; GM - divots on gingival-third of lingual surface and middle-third of labial surface; MI - divots on middle-third of lingual surface and incisal-third of labial surface; MM - divots on middle-third of lingual surface and middle-third of labial surface. Aligners (n = 30/model) were fabricated using a 0.75 mm thick polyethylene terephthalate material and Biostar® machine following the manufacturer's recommendations. A one-way MANOVA followed by one-way ANOVA (α = 0.05) was utilized to test effect of models on buccolingual force (Fy) and mesiodistal moment (Mx) at 0.20 mm of lingual displacement of the right maxillary central incisor. RESULTS Mean Mx for GI (-5.68 ± 7.38 Nmm), GM (3.75 ± 5.54 Nmm), MI (-4.27 ± 1.48 Nmm) and MM (1.96 ± 0.99 Nmm) models showed statistical differences between GI and GM, GI and MM, GM and MI and MI and MM. GI exerted the largest Fy (1.87 ± 0.75 N) followed by GM (1.10 ± 0.47 N), MI (0.70 ± 0.23 N) and MM (0.28 ± 0.08 N) with significant differences between GI and GM, GI and MI, GI and MM and GM and MM models. CONCLUSIONS Vertical divot placement on a right central incisor had a significant effect on aligner biomechanics. Buccolingual forces exerted by models GI, GM and MI were within the range suggested by literature for bodily tooth movement without major root tipping for GM and MI models.
Collapse
Affiliation(s)
- Harsimrat Kaur
- Faculty of Medicine & Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Tsolmonbaatar Khurelbaatar
- Faculty of Engineering - Mechanical Engineering Department, University of Alberta, Edmonton, Alberta, Canada
| | - James Mah
- School of Dental Medicine, University of Nevada, Las Vegas, Nevada, USA
| | - Giseon Heo
- Faculty of Medicine & Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Paul W Major
- Faculty of Medicine & Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Dan L Romanyk
- Faculty of Medicine & Dentistry, University of Alberta, Edmonton, Alberta, Canada
- Faculty of Engineering - Mechanical Engineering Department, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
2
|
Huang K, Gao S, Zou C, Zhang C, Peng Y, Liu X. Research on path planning for clear aligner flexible manufacturing. Sci Rep 2024; 14:15017. [PMID: 38951557 PMCID: PMC11217393 DOI: 10.1038/s41598-024-64546-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Accepted: 06/10/2024] [Indexed: 07/03/2024] Open
Abstract
In recent years, clear aligner can enhance individual appearance with dental defects, so it used more and more widely. However, in manufacturing process, there are still some problems, such as low degree of automation and high equipment cost. The problem of coordinate system mismatch between gingival curve point cloud and dental CAD model is faced to. The PCA-ICP registration algorithm is proposed, which includes coarse match algorithm and improve-ICP registration algorithm. The principal component analysis (PCA) based method can roughly find the posture relationship between the two point clouds. Using z-level dynamic hierarchical, the ICP registration can accurately find the posture between these two clouds. The final registration maximum distance error is 0.03 mm, which is smaller than robot machining error. Secondly, the clear aligner machining process is conducted to verify the registration effectiveness. Before machining, the path is generated based on the well registered gingival curve. After full registration, the tool path is calculated by establishing a local coordinate system between the workpiece and the tool to avoid interference. This path is calculated and generated as an executable program for ABB industrial robots. Finally, the robot was used for flexible cutting of clear aligners and was able to extract products, ensuring the effectiveness of the proposed research. This method can effectively solve the limitations of traditional milling path planning under such complex conditions.
Collapse
Affiliation(s)
- Kuntao Huang
- School of Mechanical & Electrical Engineering, Wuhan Institute of Technology, Wuhan, 430205, China
- Hubei Research Center of Intelligent Welding Equipment and Software Engineering Technology, Wuhan Institute of Technology, Wuhan, 430205, China
| | - Sheng Gao
- School of Mechanical & Electrical Engineering, Wuhan Institute of Technology, Wuhan, 430205, China
- Hubei Research Center of Intelligent Welding Equipment and Software Engineering Technology, Wuhan Institute of Technology, Wuhan, 430205, China
| | - Cheng Zou
- School of Mechanical & Electrical Engineering, Wuhan Institute of Technology, Wuhan, 430205, China
- Hubei Research Center of Intelligent Welding Equipment and Software Engineering Technology, Wuhan Institute of Technology, Wuhan, 430205, China
| | - Cong Zhang
- School of Mechanical & Electrical Engineering, Wuhan Institute of Technology, Wuhan, 430205, China.
- Hubei Research Center of Intelligent Welding Equipment and Software Engineering Technology, Wuhan Institute of Technology, Wuhan, 430205, China.
- State Key Laboratory of Intelligent Manufacturing Equipment and Technology, Wuhan, 430223, China.
| | - Yili Peng
- School of Mechanical & Electrical Engineering, Wuhan Institute of Technology, Wuhan, 430205, China
- Hubei Research Center of Intelligent Welding Equipment and Software Engineering Technology, Wuhan Institute of Technology, Wuhan, 430205, China
| | - Xi Liu
- Suzhou Hyperion Robotics Technology Co., Ltd, Suzhou, 215299, China
| |
Collapse
|
3
|
Li N, Wang C, Yang M, Chen D, Tang M, Li D, Qiu S, Chen Q, Feng Y. Effects of different tooth movement patterns and aligner thicknesses on maxillary arch expansion with clear aligners: a three-dimensional finite element study. Front Bioeng Biotechnol 2024; 12:1424319. [PMID: 38983604 PMCID: PMC11231920 DOI: 10.3389/fbioe.2024.1424319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Accepted: 06/07/2024] [Indexed: 07/11/2024] Open
Abstract
Objectives The objective of this study was to investigate the biomechanical effects of different tooth movement patterns and aligner thicknesses on teeth and periodontal tissues during maxillary arch expansion with clear aligners, to facilitate more precise and efficient clinical orthodontic treatments. Methods Three-dimensional models including teeth, maxilla, periodontal ligament, and aligner were constructed and subjected to finite element analysis. Tooth displacement trends and periodontal ligament stresses were measured for seven tooth displacement patterns (divided into three categories including overall movement of premolars and molars with gradually increasing molar expansion in each step; distributed movement of premolars and molars; and alternating movement between premolars and molars at intervals) and two aligner thicknesses (0.5Â mm and 0.75Â mm) during maxillary arch expansion with clear aligners. Results When expanding the maxillary arch with clear aligners, the effective expansion of the target teeth mainly showed a tilting movement trend. Increasing the amount of molar expansion increased the buccal displacement of the first molar but decreased the buccal displacement of the premolars. The mean buccal displacement of the target teeth was greater in the posterior teeth interval alternating movement group (0.026Â mm) than in the premolar/molar distributed movement group (0.016Â mm) and the overall movement group (0.015Â mm). Increasing aligner thickness resulted in greater buccal displacement of the crowns and increased stress on the periodontal ligaments. Conclusion Increasing the amount of molar expansion reduces the efficiency of premolar expansion. Alternating movement of premolars and molars at intervals achieves a higher arch expansion efficiency, but attention should be paid to the anchorage of adjacent teeth. Increasing the thickness of the aligner increases the expansion efficiency but may also increase the burden on the periodontal tissues.
Collapse
Affiliation(s)
- Na Li
- Silk Crossing Clinic, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
- Department of Stomatology, North Sichuan Medical College, Nanchong, China
| | - ChunJuan Wang
- Chongqing Key Laboratory of Oral Diseases, Chongqing Municipal Key Laboratory of Stomatological Biomedical Engineering, Chongqing, China
| | - Min Yang
- Department of Stomatology, North Sichuan Medical College, Nanchong, China
| | - DingGen Chen
- Silk Crossing Clinic, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
- Department of Stomatology, North Sichuan Medical College, Nanchong, China
| | - MingYuan Tang
- Department of Stomatology, North Sichuan Medical College, Nanchong, China
| | - DaoKun Li
- Department of Stomatology, North Sichuan Medical College, Nanchong, China
| | - ShengLei Qiu
- Department of Stomatology, North Sichuan Medical College, Nanchong, China
| | - Qi Chen
- Department of Stomatology, North Sichuan Medical College, Nanchong, China
| | - Yi Feng
- Department of Stomatology, North Sichuan Medical College, Nanchong, China
| |
Collapse
|
4
|
Castilhos JS, Gasparello GG, Mota-Júnior SL, Hartmann GC, Miyagusuku LFI, Pithon MM, Tanaka OM. Accessories in clear aligner therapy: Laypeople's expectations for comfort and satisfaction. J Dent Res Dent Clin Dent Prospects 2024; 18:102-109. [PMID: 39071215 PMCID: PMC11282201 DOI: 10.34172/joddd.40793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Accepted: 01/20/2024] [Indexed: 07/30/2024] Open
Abstract
Background This study explored the layperson's perception of comfort, satisfaction, and willingness to use various accessories in clear aligner therapy. Methods A total of 267 people analyzed standardized intraoral photographs of a female model in orthodontic treatment using: 1) only clear aligner (CA), the control group; 2) clear aligner+attachments (AT); 3) clear aligners+Cl II elastics (EL); 4) clear aligner+hybrid treatment with esthetic braces (HEB); 5) Clear aligner+hybrid treatment with metallic braces (HMB); 6) clear aligner+mini-implants (MI); 7) clear aligner+mini-implants and elastics for intrusion (MIE). In addition, a social media questionnaire was distributed to assess the willingness to undergo orthodontic treatment with various accessories. Results There was a significant difference between CA and all the other groups (P<0.001), with CA being considered more comfortable and providing greater satisfaction compared to other accessories. Moreover, AT showed a significant difference in reducing treatment time compared to other groups. Conclusion The CA was the most comfortable, exhibiting a higher satisfaction rate and a greater willingness to use it. The AT therapy was perceived as more comfortable and was associated with higher satisfaction and a greater likelihood of use, especially if it resulted in reduced treatment time. On the other hand, the participants reported that the HMB, MI, and MIE accessories were less comfortable.
Collapse
Affiliation(s)
- Jussimar Scheffer Castilhos
- Department of Orthodontics, Medicine and Life Sciences School, PontifÃcia Universidade Católica do Paraná, Curitiba, Brazil
| | - Gil Guilherme Gasparello
- Department of Orthodontics, Medicine and Life Sciences School, PontifÃcia Universidade Católica do Paraná, Curitiba, Brazil
| | - Sergio Luiz Mota-Júnior
- Orthodontist, Private Practice, Juiz de Fora Federal University, Juiz de Fora, Minas Gerais, Brazil
| | - Giovani Ceron Hartmann
- Department of Orthodontics, Medicine and Life Sciences School, PontifÃcia Universidade Católica do Paraná, Curitiba, Brazil
| | - Luiz Fernando Iyda Miyagusuku
- Undergraduate Student in Dentistry, Medicine and Life Sciences School, PontifÃcia Universidade Católica do Paraná, Curitiba, Brazil
| | - Matheus Melo Pithon
- Department of Orthodontics, Southwest Bahia State University – UESB, Jequié, Bahia, Brazil
| | - Orlando Motohiro Tanaka
- Department of Orthodontics, Medicine and Life Sciences School, PontifÃcia Universidade Católica do Paraná, Curitiba, Brazil
| |
Collapse
|
5
|
Elshazly TM, Bourauel C, Chavanne P, Elattar H, Keilig L. Numerical biomechanical finite element analysis of different trimming line designs of orthodontic aligners: An in silico study. J World Fed Orthod 2024; 13:65-71. [PMID: 38395726 DOI: 10.1016/j.ejwf.2024.01.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 12/23/2023] [Accepted: 01/03/2024] [Indexed: 02/25/2024]
Abstract
BACKGROUND A finite element model was used to investigate the effect of different designs and thicknesses of orthodontic aligner margins on their biomechanical behavior. METHODS A three-dimensional data set of an upper jaw was imported into the 3-matic software. The upper right central incisor tooth (Tooth 11) was separated from the remaining model, and its periodontal ligament and surrounding bone were designed. Aligners were designed with four different trimming lines (scalloped, straight, scalloped extended, straight extended), each with four different thicknesses (0.3, 0.4, 0.5, and 0.6 mm). The models were imported into a finite element package (Marc/Mentat). A linear elastic constitutive material model was applied. A facial 0.2 mm bodily malalignment of tooth 11 was simulated. RESULTS The maximum resultant force was in the range of 1.0 N to 2.2 N. The straight trimming designs deliver higher resultant forces compared with scalloped trimming designs. Increasing the aligner thickness and/or extending the aligner edge beyond the gingival line leads to an increase in the resultant force. All designs showed an uneven distribution of the normal contact forces over the tooth surface with a predominant concentration toward the cervical third and distal third, particularly with the extended trimming designs. All designs showed uncontrolled tipping of the tooth. CONCLUSIONS Based on the current model outcomes, the use of a straight extended trimming line design for aligners is favored because of its positive impact on force distribution and, consequently, the control of tooth movement. CLINICAL RELEVANCE These findings provide aligner companies and orthodontists a valuable biomechanical evidence and guidance to enhance control over tooth movement and therefore optimize treatment outcomes. This can be achieved by trimming the edges of aligners with a straight extended design and selecting the appropriate aligner thickness.
Collapse
Affiliation(s)
- Tarek M Elshazly
- Oral Technology, Dental School, University Hospital Bonn, Bonn, Germany.
| | | | | | - Hanaa Elattar
- Orthodontic Department, Faculty of Dentistry, Suez Canal University, Ismailia, Egypt
| | - Ludger Keilig
- Oral Technology, Dental School, University Hospital Bonn, Bonn, Germany; Department of Dental Prosthetics, Propaedeutics and Materials Science, Dental School, University Hospital Bonn, Bonn, Germany
| |
Collapse
|
6
|
Slaymaker J, Hirani S, Woolley J. Direct 3D printing aligners - past, present and future possibilities. Br Dent J 2024; 236:401-405. [PMID: 38459321 DOI: 10.1038/s41415-024-7126-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 06/29/2023] [Accepted: 07/10/2023] [Indexed: 03/10/2024]
Abstract
The aim of this paper is to introduce the general dentist to recent advances in 3D printing technology used in orthodontics. 3D printing is a highly evolving area of dentistry with continual developments. New advances now allow the in-house delivery of printed aligners. Advocates of this new technology suggest the benefits of more prescriptive and controlled tooth movement in comparison to conventional thermoformed appliances. However, there is currently limited evidence on the efficiency of this material and more research needs to be carried out to validate this new technology.
Collapse
Affiliation(s)
| | - Sunil Hirani
- Specialist Orthodontist, Milton Keynes, England, UK
| | - Julian Woolley
- Orthodontic Registrar, Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom
| |
Collapse
|
7
|
Narongdej P, Hassanpour M, Alterman N, Rawlins-Buchanan F, Barjasteh E. Advancements in Clear Aligner Fabrication: A Comprehensive Review of Direct-3D Printing Technologies. Polymers (Basel) 2024; 16:371. [PMID: 38337260 DOI: 10.3390/polym16030371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 01/25/2024] [Accepted: 01/25/2024] [Indexed: 02/12/2024] Open
Abstract
Clear aligners have revolutionized orthodontic treatment by offering an esthetically driven treatment modality to patients of all ages. Over the past two decades, aligners have been used to treat malocclusions in millions of patients worldwide. The inception of aligner therapy goes back to the 1940s, yet the protocols to fabricate aligners have been continuously evolved. CAD/CAM driven protocol was the latest approach which drastically changed the scalability of aligner fabrication-i.e., aligner mass production manufacturing. 3D printing technology has been adopted in various sectors including dentistry mostly because of the ability to create complex geometric structures at high accuracy while reducing labor and material costs-for the most part. The integration of 3D printing in dentistry has been across, starting in orthodontics and oral surgery and expanding in periodontics, prosthodontics, and oral implantology. Continuous progress in material development has led to improved mechanical properties, biocompatibility, and overall quality of aligners. Consequently, aligners have become less invasive, more cost-effective, and deliver outcomes comparable to existing treatment options. The promise of 3D printed aligners lies in their ability to treat malocclusions effectively while providing esthetic benefits to patients by remaining virtually invisible throughout the treatment process. Herein, this review aims to provide a comprehensive summary of studies regarding direct-3D printing of clear aligners up to the present, outlining all essential properties required in 3D-printed clear aligners and the challenges that need to be addressed. Additionally, the review proposes implementation methods to further enhance the effectiveness of the treatment outcome.
Collapse
Affiliation(s)
- Poom Narongdej
- Department of Mechanical and Aerospace Engineering, California State University Long Beach, Long Beach, CA 90840, USA
- Institute of Mathematical Sciences, Claremont Graduate University, Claremont, CA 91711, USA
| | - Mana Hassanpour
- Department of Chemical Engineering, California State University Long Beach, Long Beach, CA 90840, USA
| | - Nicolas Alterman
- Department of Mechanical and Aerospace Engineering, California State University Long Beach, Long Beach, CA 90840, USA
| | | | - Ehsan Barjasteh
- Department of Mechanical and Aerospace Engineering, California State University Long Beach, Long Beach, CA 90840, USA
- Department of Chemical Engineering, California State University Long Beach, Long Beach, CA 90840, USA
| |
Collapse
|
8
|
Gao J, Guo D, Zhang X, Cheng Y, Zhang H, Xu Y, Jin Z, Ma Y. Biomechanical effects of different staging and attachment designs in maxillary molar distalization with clear aligner: a finite element study. Prog Orthod 2023; 24:43. [PMID: 38044352 PMCID: PMC10694119 DOI: 10.1186/s40510-023-00493-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 09/26/2023] [Indexed: 12/05/2023] Open
Abstract
BACKGROUND In the present study, the effects of distalizations of one and two molars with different step distances and attachment designs have been analyzed. METHODS A 3D finite element analysis model has been developed in order to determine the tendency of tooth displacement and stress distribution with clear aligner treatment. RESULTS Under the condition of single-molar distalization, when the step distance was set to 0.25Â mm, the total displacement was 0.086Â mm for central incisors, 0.080Â mm for lateral incisors, 0.084Â mm for canines, 0.102Â mm for the first premolar and 0.076Â mm for the second premolar. The von Mises stress of roots and the principal stress of the periodontal ligament was slightly lower than in the control group when the step distance was set to 0.130Â mm. Under the condition of two-molar distalization, when the step distance was set to 0.130Â mm, the total displacements for central incisors, lateral incisors and canines as well as both the first and second maxillary molars were basically the same as with a distance of 0.250Â mm for one-molar distalization. In addition, when the step distance was 0.130Â mm with two-molar distalization, the rotation center of the first and second molar was closer to the apex of the root indicating that the smaller step distance led to more bodily movement during the two-molar distalization. However, displacement tendencies of the first molar and the second molar were basically the same whether horizontal or vertical rectangular attachments were added. CONCLUSIONS A step distance of moving two molars to 0.130Â mm can achieve the same reaction force on the anterior teeth as moving one molar 0.250Â mm without effects on horizontal or vertical rectangular attachments. CLINICAL RELEVANCE Our results provide a theoretical basis and guidance for simultaneously moving two molars backward in clinical practice using a clear aligner.
Collapse
Affiliation(s)
- Jie Gao
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Clinical Research Center for Oral Diseases, Department of Orthodontics, School of Stomatology, The Fourth Military Medical University, No. 169 Changle West Road, Xi'an, 710032, China
| | - Donghui Guo
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Clinical Research Center for Oral Diseases, Department of Orthodontics, School of Stomatology, The Fourth Military Medical University, No. 169 Changle West Road, Xi'an, 710032, China
| | - Xu Zhang
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Clinical Research Center for Oral Diseases, Department of Orthodontics, School of Stomatology, The Fourth Military Medical University, No. 169 Changle West Road, Xi'an, 710032, China
| | - Yuxun Cheng
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Clinical Research Center for Oral Diseases, Department of Orthodontics, School of Stomatology, The Fourth Military Medical University, No. 169 Changle West Road, Xi'an, 710032, China
| | - Hao Zhang
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Clinical Research Center for Oral Diseases, Department of Orthodontics, School of Stomatology, The Fourth Military Medical University, No. 169 Changle West Road, Xi'an, 710032, China
| | - Yuerong Xu
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Clinical Research Center for Oral Diseases, Department of Orthodontics, School of Stomatology, The Fourth Military Medical University, No. 169 Changle West Road, Xi'an, 710032, China
| | - Zuolin Jin
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Clinical Research Center for Oral Diseases, Department of Orthodontics, School of Stomatology, The Fourth Military Medical University, No. 169 Changle West Road, Xi'an, 710032, China.
| | - Yanning Ma
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Clinical Research Center for Oral Diseases, Department of Orthodontics, School of Stomatology, The Fourth Military Medical University, No. 169 Changle West Road, Xi'an, 710032, China.
- Shanxi Medical University School and Hospital of Stomatology, Taiyuan, 030001, China.
| |
Collapse
|
9
|
Shrivastava A, Mohanty P, Dash BP, Jena S, Sahoo N. Proficiency of Clear Aligner Therapy: A Systematic Review and Meta-Analysis. Cureus 2023; 15:e45072. [PMID: 37842499 PMCID: PMC10568240 DOI: 10.7759/cureus.45072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/11/2023] [Indexed: 10/17/2023] Open
Abstract
The aim of this study was to evaluate the efficacy and efficiency of orthodontic treatment using clear aligner therapy (CAT). This efficiency was measured using the Peer Assessment Rating (PAR) index, the American Board of Orthodontics (ABO) index, or the similarity between the final ClinCheck and the final scanned models. A search was done electronically between 1998 and 2021 using the Cochrane Library, PubMed, and Google Scholar databases. Three reviewers individually rated the articles. The ROBINS tool and the Cochrane risk of bias tool were used to evaluate the quality of observational research and randomized controlled trials, respectively. The degree of certainty for each selected outcome was evaluated using the grading of recommendations assessment, development, and evaluation (GRADE) approach. Six studies with a total of 166 participants were considered after the full texts of 61 potential reports were reviewed. This research included in the review covered the period from 1998 to 2021 in retrospect. According to the current systematic review and meta-analysis, transparent aligners had a successful outcome. In mild to moderate cases, aligner treatment appears to have a significant advantage in terms of efficiency (treatment time); nonetheless, insufficient evidence of efficacy was observed based on multiple cross-sectional investigations. When compared to traditional brackets, clear aligners provided a more stable course of treatment.
Collapse
Affiliation(s)
- Akshay Shrivastava
- Department of Orthodontics and Dentofacial Orthopaedics, Kalinga Institute of Dental Sciences, Kalinga Institute of Industrial Technology (KIIT) (Deemed to be University), Bhubaneswar, IND
| | - Pritam Mohanty
- Department of Orthodontics, Kalinga Institute of Dental Sciences, Kalinga Institute of Industrial Technology (KIIT) (Deemed to be University), Bhubaneswar, IND
| | - Bhagabati P Dash
- Department of Orthodontics and Dentofacial Orthopaedics, Kalinga Institute of Dental Sciences, Kalinga Institute of Industrial Technology (KIIT) (Deemed to be University), Bhubaneswar, IND
| | - Sanghamitra Jena
- Department of Orthodontics and Dentofacial Orthopaedics, Kalinga Institute of Dental Sciences, Kalinga Institute of Industrial Technology (KIIT) (Deemed to be University), Bhubaneswar, IND
| | - Nivedita Sahoo
- Department of Orthodontics and Dentofacial Orthopaedics, Kalinga Institute of Dental Sciences, Kalinga Institute of Industrial Technology (KIIT) (Deemed to be University), Bhubaneswar, IND
| |
Collapse
|
10
|
Meng X, Wang C, Xu W, Wang R, Zheng L, Wang C, Aversa R, Fan Y. Effects of different designs of orthodontic clear aligners on the maxillary central incisors in the tooth extraction cases: a biomechanical study. BMC Oral Health 2023; 23:416. [PMID: 37349701 PMCID: PMC10288704 DOI: 10.1186/s12903-023-03106-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Accepted: 06/05/2023] [Indexed: 06/24/2023] Open
Abstract
BACKGROUND Controlling the 3D movement of central incisors during tooth extraction cases with clear aligners is important but challenging in invisible orthodontic treatment. This study aimed to explore the biomechanical effects of central incisors in tooth extraction cases with clear aligners under different power ridge design schemes and propose appropriate advice for orthodontic clinic. METHODS A series of Finite Element models was constructed to simulate anterior teeth retraction or no retraction with different power ridge designs. These models all consisted of maxillary dentition with extracted first premolars, alveolar bone, periodontal ligaments and clear aligner. And the biomechanical effects were analysed and compared in each model. RESULTS For the model of anterior teeth retraction without power ridge and for the model of anterior teeth no retraction with a single power ridge, the central incisors exhibited crown lingual inclination and relative extrusion. For the model of anterior teeth no retraction with double power ridges, the central incisors tended to have crown labial inclination and relative intrusion. For the model of anterior tooth retraction with double power ridges, the central incisors exhibited a similar trend to the first kind of model, but as the depth of the power ridge increased, there was a gradual decrease in crown retraction value and an increase in crown extrusion value. The simulated results showed that von-Mises stress concentration was observed in the cervical and apical regions of the periodontal ligaments of the central incisors. The clear aligner connection areas of adjacent teeth and power ridge areas also exhibited von-Mises stress concentration and the addition of power ridge caused the clear aligner to spread out on the labial and lingual sides. CONCLUSIONS The central incisors are prone to losing torque and extruding in tooth extraction cases. Double power ridges have a certain root torque effect when there are no auxiliary designs, but they still cannot rescue tooth inclination during tooth retraction period. For tooth translation, it may be a better clinical procedure to change the one-step aligner design to two-step process: tilting retraction and root control.
Collapse
Affiliation(s)
- Xuehuan Meng
- Stomatological Hospital of Chongqing Medical University, No.426 Songshibei Road, Yubei District, Chongqing, 401147, China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, No.426 Songshibei Road, Yubei District, Chongqing, 401147, China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, No.426 Songshibei Road, Yubei District, Chongqing, 401147, China
| | - Chunjuan Wang
- Stomatological Hospital of Chongqing Medical University, No.426 Songshibei Road, Yubei District, Chongqing, 401147, China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, No.426 Songshibei Road, Yubei District, Chongqing, 401147, China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, No.426 Songshibei Road, Yubei District, Chongqing, 401147, China
| | - Wenjie Xu
- Stomatological Hospital of Chongqing Medical University, No.426 Songshibei Road, Yubei District, Chongqing, 401147, China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, No.426 Songshibei Road, Yubei District, Chongqing, 401147, China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, No.426 Songshibei Road, Yubei District, Chongqing, 401147, China
| | - Rui Wang
- Stomatological Hospital of Chongqing Medical University, No.426 Songshibei Road, Yubei District, Chongqing, 401147, China
| | - Leilei Zheng
- Stomatological Hospital of Chongqing Medical University, No.426 Songshibei Road, Yubei District, Chongqing, 401147, China.
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, No.426 Songshibei Road, Yubei District, Chongqing, 401147, China.
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, No.426 Songshibei Road, Yubei District, Chongqing, 401147, China.
| | - Chao Wang
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, No.37, Xueyuan Road, Beijing, 100083, China.
| | - Raffaella Aversa
- Advanced Material Lab, University of Campania, Luigi Vanvitelli, Caserta, Italy
| | - Yubo Fan
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, No.37, Xueyuan Road, Beijing, 100083, China
| |
Collapse
|
11
|
Yao S, Jiang W, Wang C, He Y, Wang C, Huang L. Improvements of tooth movement efficiency and torque control in expanding the arch with clear aligners: a finite element analysis. Front Bioeng Biotechnol 2023; 11:1120535. [PMID: 37324442 PMCID: PMC10267454 DOI: 10.3389/fbioe.2023.1120535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Accepted: 05/25/2023] [Indexed: 06/17/2023] Open
Abstract
Objectives: The purpose of this study was to analyze the effect of different movement strategies, embossment structures, and torque compensation of the aligner on tooth movement during arch expansion using clear aligners by finite element analysis. Methods: Models comprising the maxilla, dentition, periodontal ligament, and aligners were created and imported into a finite element analysis software. The tests were performed using the following: three orders of tooth movement (including alternating movement with the first premolar and first molar, whole movement with second premolar and first molar or premolars and first molar), four different shapes of embossment structures (ball, double ball, cuboid, cylinder, with 0.05, 0.1, 0.15-mm interference) and torque compensation (0°, 1°, 2°, 3°, 4°, and 5°). Results: The expansion of clear aligners caused the target tooth to move obliquely. Alternating movement resulted in higher movement efficiency with lower anchorage loss as compared with whole movement. Embossment increased the efficiency of crown movement but did not contribute positively to torque control. As the angle of compensation increased, the tendency of oblique tooth movement was gradually controlled; however, the movement efficiency decreased concurrently, and stress distribution on the periodontal ligament became more even. For each 1° increase in compensation, the torque per millimeter of the first premolar would decrease by 0.26°/mm, and the crown movement efficiency eliminate decreased by 4.32%. Conclusion: Alternating movement increases the efficiency of the arch expansion by the aligner and reduces anchorage loss. Torque compensation should be designed to enhance torque control in arch expansion using an aligner.
Collapse
Affiliation(s)
- Song Yao
- Stomatological Hospital of Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Wei Jiang
- Stomatological Hospital of Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Chunjuan Wang
- Stomatological Hospital of Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Yao He
- Stomatological Hospital of Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Chao Wang
- Stomatological Hospital of Chongqing Medical University, Chongqing, China
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, Beijing, China
| | - Lan Huang
- Stomatological Hospital of Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| |
Collapse
|
12
|
Alam MK, Kanwal B, Shqaidef A, Alswairki HJ, Alfawzan AA, Alabdullatif AI, Aalmunif AN, Aljrewey SH, Alothman TA, Shrivastava D, Srivastava KC. A Systematic Review and Network Meta-Analysis on the Impact of Various Aligner Materials and Attachments on Orthodontic Tooth Movement. J Funct Biomater 2023; 14:jfb14040209. [PMID: 37103299 PMCID: PMC10141153 DOI: 10.3390/jfb14040209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Revised: 03/21/2023] [Accepted: 04/06/2023] [Indexed: 04/28/2023] Open
Abstract
The majority of patients strongly favor the use of aligners in the present time, especially with the advancement in esthetic dentistry. Today's market is flooded with aligner companies, many of which share the same therapeutic ethos. We therefore carried out a systematic review and network meta-analysis to evaluate research that had looked at various aligner materials and attachments and their effect on orthodontic tooth movement in relevant studies. A total of 634 papers were discovered after a thorough search of online journals using keywords such as "Aligners", "Orthodontics", "Orthodontic attachments", "Orthodontic tooth movement", and "Polyethylene" across databases such as PubMed, Web of Science, and Cochrane. The authors individually and in parallel carried out the database investigation, removal of duplicate studies, data extraction, and bias risk. The statistical analysis demonstrated that the type of aligner material had a significant impact on orthodontic tooth movement. The low level of heterogeneity and significant overall effect further support this finding. However, there was little effect of attachment size or shape on tooth mobility. The examined materials were primarily concerned with influencing the physical/physicochemical characteristics of the appliances and not tooth movement directly. Invisalign (Inv) had a higher mean value than the other types of materials that were analyzed, which suggested a potentially greater impact on orthodontic tooth movement. However, its variance value indicated that there was also greater uncertainty associated with the estimate compared to some of the other plastics. These findings could have important implications for orthodontic treatment planning and aligner material selection. Registration: This review protocol was registered on the International Prospective Register of Systematic Reviews (PROSPERO; registration number: CRD42022381466).
Collapse
Affiliation(s)
- Mohammad Khursheed Alam
- Orthodontic Division, Preventive Dentistry Department, College of Dentistry, Jouf University, Sakaka 72345, Saudi Arabia
- Department of Dental Research Cell, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Chennai 602105, India
- Department of Public Health, Faculty of Allied Health Sciences, Daffodil lnternational University, Dhaka 1216, Bangladesh
| | - Bushra Kanwal
- Practicing in Dental Clinic, Al Baha 65511, Saudi Arabia
| | - Abedalrahman Shqaidef
- Department of Clinical Sciences, Center of Medical and Bio-Allied Health Sciences Research, College of Dentistry, Ajman University, Ajman 346, United Arab Emirates
| | | | - Ahmed Ali Alfawzan
- Department of Preventive Dentistry, College of Dentistry in Ar Rass, Qassim University, Ar Rass 52571, Saudi Arabia
| | | | | | | | | | - Deepti Shrivastava
- Periodontics Division, Preventive Dentistry Department, College of Dentistry, Jouf University, Sakaka 72345, Saudi Arabia
| | - Kumar Chandan Srivastava
- Oral Medicine & Maxillofacial Radiology Division, Department of Oral & Maxillofacial Surgery & Diagnostic Sciences, College of Dentistry, Jouf University, Sakaka 72345, Saudi Arabia
| |
Collapse
|
13
|
Yang Y, Yang R, Liu L, Zhang X, Jiang Q, Fan Q, Zhang H, Long H, Lai W. The effects of aligner anchorage preparation on mandibular first molars during premolar-extraction space closure with clear aligners: A finite element study. Am J Orthod Dentofacial Orthop 2023:S0889-5406(23)00098-7. [PMID: 37024337 DOI: 10.1016/j.ajodo.2022.12.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 12/01/2022] [Accepted: 12/01/2022] [Indexed: 04/08/2023]
Abstract
INTRODUCTION This study aimed to determine the effectiveness of different aligner anchorage preparations on mandibular first molars during premolar-extraction space closure with clear aligners and to assess the effects of different modes of Class II elastics on mandibular first molars. METHODS Finite element models were constructed on the basis of cone-beam computed tomography data from an orthodontic patient. The models comprised maxilla, mandible, maxillary and mandibular teeth without first premolars, periodontal ligaments, attachments and aligners. Tooth displacement tendencies were calculated using different aligner anchorage preparations and Class II elastics on the models from the same patient. Three group sets were designed on the basis of the positions of aligner cutouts and buttons (mesiobuccal, distobuccal and lingual). Four groups were established in each of the 3 group sets. Four groups were created: (1) no elastic traction + no anchorage preparation, (2) anchorage preparation only, (3) elastic traction only, and (4) elastic traction + anchorage preparation. Different aligner anchorage preparations (0°, 1°, 2°, 3°) were applied on mandibular second premolars and molars. The Class II traction force was set to 100 g. RESULTS With clear aligners, mandibular first molars were subject to mesial tipping, lingual tipping and intrusion. In the condition of no elastic traction, aligner anchorage preparation resulted in distal tipping, buccal tipping, and extrusion effect on mandibular first molars. Aligner anchorage preparation was more effective in the distal and lingual cutout groups than in the mesial cutout group. In the condition of Class II elastic traction, the bodily movement of mandibular first molars was achieved with a 3° anchorage preparation for the mesial cutout group and a 1.7° anchorage preparation for distal and lingual cutout groups. Absolute maximal anchorage was achieved with a 2° anchorage preparation for distal and lingual cutout groups. CONCLUSIONS Clear aligner therapy caused mesial tipping, lingual tipping and intrusion of mandibular first molars during premolar-extraction space closure. Aligner anchorage preparation effectively prevented mesial and lingual tipping of mandibular molars. Distal and lingual cutout modes were more effective than mesial cutout modes in aligner anchorage preparation. For each aligner stage (0.25 mm), 1.7° aligner anchorage preparation and Class II elastics with distal or lingual cutouts led to the bodily movement of mandibular first molars, whereas 2° anchorage preparation reached absolute maximal anchorage.
Collapse
Affiliation(s)
- Yi Yang
- Department of Orthodontics, State Key Laboratory of Oral Diseases and National Clinical Center for Oral Research, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Ruicong Yang
- Department of Orthodontics, Peking University School and Hospital of Stomatology, Beijing, China
| | - Lu Liu
- Department of Orthodontics, State Key Laboratory of Oral Diseases and National Clinical Center for Oral Research, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Xiaoqi Zhang
- Department of Orthodontics, State Key Laboratory of Oral Diseases and National Clinical Center for Oral Research, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Qingsong Jiang
- Department of Orthodontics, State Key Laboratory of Oral Diseases and National Clinical Center for Oral Research, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Qi Fan
- Department of Orthodontics, State Key Laboratory of Oral Diseases and National Clinical Center for Oral Research, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Haoxin Zhang
- Department of Orthodontics, State Key Laboratory of Oral Diseases and National Clinical Center for Oral Research, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Hu Long
- Department of Orthodontics, State Key Laboratory of Oral Diseases and National Clinical Center for Oral Research, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
| | - Wenli Lai
- Department of Orthodontics, State Key Laboratory of Oral Diseases and National Clinical Center for Oral Research, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
| |
Collapse
|
14
|
Elshazly TM, Salvatori D, Elattar H, Bourauel C, Keilig L. Effect of trimming line design and edge extension of orthodontic aligners on force transmission: A 3D finite element study. J Mech Behav Biomed Mater 2023; 140:105741. [PMID: 36857974 DOI: 10.1016/j.jmbbm.2023.105741] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 02/20/2023] [Accepted: 02/21/2023] [Indexed: 02/27/2023]
Abstract
OBJECTIVES To investigate in a numerical study the effect of the geometry and the extension of orthodontic aligner edges and the aligner thickness on force transmission to upper right central incisor tooth (Tooth 11). METHODS A three-dimensional (3D) digital model, obtained from a 3D data set of a complete dentulous maxilla, was imported into 3-matic software. Aligners with four different trimming line designs (scalloped, straight, scalloped extended, straight extended) were designed, each with four different thicknesses (0.3, 0.4, 0.5, and 0.6Â mm). The models were exported to a finite element (FE) software (Marc/Mentat). A facial 0.2Â mm bodily malposition of tooth 11 was simulated. RESULTS The maximum resultant force was in the range of (7.5 - 55.2) N. The straight trimming designs had higher resultant force than the scalloped designs. The resultant force increases with increasing the edge extension of the aligner. The normal contact forces were unevenly distributed over the entire surface and were concentrated in six areas: Incisal, Mesio-Incisal, Disto-Incisal, Middle, Mesio-Cervical, and Disto-Cervical. The resultant force increases super linearly with increasing thickness. CONCLUSIONS The design of the trimming line, the edge extension, and the thickness of the aligner affect significantly the magnitude of the resultant force and the distribution of normal contact force. The straight extended trimming design exhibited better force distribution that may favor a bodily tooth movement. CLINICAL RELEVANCE A straight extended trimming design of an orthodontic aligner may improve the clinical outcomes. In addition, the manufacturing procedures of the straight design are much simpler compared to the scalloped design.
Collapse
Affiliation(s)
- Tarek M Elshazly
- Oral Technology, Dental School, University Hospital Bonn, Bonn, Germany.
| | | | - Hanaa Elattar
- Orthodontic Department, Faculty of Dentistry, Umm Al-Qura University, Makkah, Saudi Arabia; Orthodontic Department, Faculty of Dentistry, Suez Canal University, Ismailia, Egypt
| | | | - Ludger Keilig
- Oral Technology, Dental School, University Hospital Bonn, Bonn, Germany; Department of Dental Prosthetics, Propaedeutics and Materials Science, Dental School, University Hospital Bonn, Bonn, Germany
| |
Collapse
|
15
|
Ahmad W, Jiang F, Xiong J, Xia Z. The mechanical effect of geometric design of attachments in invisible orthodontics. Am J Orthod Dentofacial Orthop 2023:S0889-5406(23)00075-6. [PMID: 36990956 DOI: 10.1016/j.ajodo.2022.11.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 11/01/2022] [Accepted: 11/01/2022] [Indexed: 03/29/2023]
Abstract
INTRODUCTION In invisible orthodontics, attachments are used with aligners to better control tooth movement. However, to what extent the geometry of the attachment can affect the biomechanical properties of the aligner is unknown. This study aimed to determine the biomechanical effect of attachment geometry on orthodontic force and moment using 3-dimensional finite element analysis. METHODS A 3-dimensional model of mandibular teeth, periodontal ligaments, and the bone complex was employed. Rectangular attachments with systematic size variations were applied to the model with corresponding aligners. Fifteen pairs were created to move the lateral incisor, canine, first premolar, and second molar mesially for 0.15 mm, respectively. The resulting orthodontic forces and moments were analyzed to compare the effect of attachment size. RESULTS Expansion in the attachment size showed a continuous increase in force and moment. Considering the attachment size, the moment increased more than the force, resulting in a slightly higher moment-to-force ratio. Expanding the length, width, or thickness of the rectangular attachment by 0.50 mm increases the force and moment up to 23 cN and 244 cN-mm, respectively. The force direction was closer to the desired movement direction with larger attachment sizes. CONCLUSIONS Based on the experimental results, the constructed model successfully simulates the effect of the size of attachments. The larger the size of the attachment, the greater the force and moment, and the better the force direction. The appropriate force and moment for a particular clinical patient can be obtained by choosing the right attachment size.
Collapse
|
16
|
Li Y, Xiao S, Jin Y, Zhu C, Li R, Zheng Y, Chen R, Xia L, Fang B. Stress and movement trend of lower incisors with different IMPA intruded by clear aligner: a three-dimensional finite element analysis. Prog Orthod 2023; 24:5. [PMID: 36775824 PMCID: PMC9922685 DOI: 10.1186/s40510-023-00454-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Accepted: 01/02/2023] [Indexed: 02/14/2023] Open
Abstract
BACKGROUND During the intrusion of lower incisors with clear aligners (CAs), root disengagement from the alveolar bone often occurs, resulting in serious complications. This study aimed to determine the potential force mechanism of the mandibular anterior teeth under the pressure of CA, providing theoretical data for clinical practice. METHODS In this study, a 3D finite element model was established, including the CA, periodontal ligament, and mandibular dentition. Incisor mandibular plane angles were set as 5 groups: 90°, 95°, 100°, 105°, and 110°. The 4 mandibular incisors were intruded by 0.2 mm, while the canines were the anchorage teeth. The stress, force systems, and potential movement trends of mandibular anterior teeth were obtained. RESULTS The compressive stress of the incisors was concentrated in the lingual fossa, incisal ridge, and apex. With the increase in IMPA, the moment of central incisors changed from lingual crown moment to labial crown moment, with the turning point between 100° and 105°, but the center of resistance (CR) was always subjected to the force toward the lingual and intrusive direction. The force and moment toward the labial side of the lateral incisors were greater than those toward the central incisors. The canines always tipped distally and received extrusive force with no relationship with IMPA. CONCLUSIONS With the increase in the initial IMPA, the direction of labiolingual force on the mandibular incisors was reversed. However, the root of the lower incisors always tipped labially, which indicated fenestration and dehiscence.
Collapse
Affiliation(s)
- Yixin Li
- grid.16821.3c0000 0004 0368 8293Department of Orthodontics, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine;College of Stomatology, Shanghai Jiao Tong University; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, 500 Quxi Road, Shanghai, 200011 China
| | - Shengzhao Xiao
- grid.16821.3c0000 0004 0368 8293Department of Orthodontics, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine;College of Stomatology, Shanghai Jiao Tong University; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, 500 Quxi Road, Shanghai, 200011 China
| | - Yu Jin
- grid.16821.3c0000 0004 0368 8293Department of Orthodontics, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine;College of Stomatology, Shanghai Jiao Tong University; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, 500 Quxi Road, Shanghai, 200011 China
| | - Cheng Zhu
- grid.16821.3c0000 0004 0368 8293Department of Orthodontics, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine;College of Stomatology, Shanghai Jiao Tong University; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, 500 Quxi Road, Shanghai, 200011 China
| | - Ruomei Li
- grid.16821.3c0000 0004 0368 8293Department of Orthodontics, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine;College of Stomatology, Shanghai Jiao Tong University; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, 500 Quxi Road, Shanghai, 200011 China
| | - Yikan Zheng
- grid.16821.3c0000 0004 0368 8293Translational Medicine Research Platform of Oral Biomechanics and Artificial Intelligence, Department of Orthodontics, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine;College of Stomatology, Shanghai Jiao Tong University; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, Shanghai, 200011 China
| | - Rongjing Chen
- Department of Orthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine;College of Stomatology, Shanghai Jiao Tong University; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, 500 Quxi Road, Shanghai, 200011, China.
| | - Lunguo Xia
- Department of Orthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine;College of Stomatology, Shanghai Jiao Tong University; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, 500 Quxi Road, Shanghai, 200011, China.
| | - Bing Fang
- Department of Orthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine;College of Stomatology, Shanghai Jiao Tong University; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, 500 Quxi Road, Shanghai, 200011, China.
| |
Collapse
|
17
|
Fan D, Liu H, Yuan CY, Wang SY, Wang PL. Effectiveness of the attachment position in molar intrusion with clear aligners: a finite element study. BMC Oral Health 2022; 22:474. [PMID: 36348394 PMCID: PMC9644447 DOI: 10.1186/s12903-022-02472-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Accepted: 09/22/2022] [Indexed: 11/09/2022] Open
Abstract
Objective To evaluate the biomechanical effects of different attachments’ position for maxillary molar intrusion with clear aligner treatment by finite element analysis. Methods Cone-beam computed tomography images of a patient with supra-eruption of the maxillary second molars were selected to construct three-dimensional models of the maxilla, periodontal ligaments, dentition, and clear aligner. The models were divided into four groups depending on the attachment location on the first molar: (1) no attachment (NA), (2) buccal attachment (BA), (3) palatal attachment (PA), and (4) bucco-palatal attachment (BPA). After applying an intrusion of 0.2 mm on the second molar, displacements and stress distributions of the teeth, aligner, and periodontal ligament were analyzed with the finite element software. Results All groups displayed equivalent movement patterns of aligners. The NA and BA groups showed buccal tipping of the second molar, while the PA group showed palatal tipping. The BPA group had the highest intruding value and the lowest buccal/palatal tipping value. All groups showed mesial tipping of the second molar. Stress distribution in the periodontal ligament strongly correlated with the attachment position. The BPA group showed the best stress distribution. Conclusion Combined BA and PA could effectively prevent buccal and palatal tipping and showed the best efficiency in intruding the second molar. The second molar showed an unavoidable tendency to tip mesially, regardless of the attachment position.
Collapse
|
18
|
Advances in orthodontic clear aligner materials. Bioact Mater 2022; 22:384-403. [PMID: 36311049 PMCID: PMC9588987 DOI: 10.1016/j.bioactmat.2022.10.006] [Citation(s) in RCA: 34] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 10/05/2022] [Accepted: 10/06/2022] [Indexed: 11/24/2022] Open
Abstract
Rapid technological improvements in biomaterials, computer-aided design (CAD) and manufacturing (CAM) have endorsed clear aligner therapy (CAT) as a mainstay of orthodontic treatment, and the materials employed for aligner fabrication play an all-important role in determining the clinical performance of clear aligners. This narrative review has attempted to comprehensively encompass the entire gamut of materials currently used for the fabrication of clear aligners and elucidate their characteristics that are crucial in determining their performance in an oral environment. Historical developments and current protocols in aligner fabrication, features of contemporary bioactive materials, and emerging trends related to CAT are discussed. Advances in aligner material chemistry and engineering possess the potential to bring about radical transformations in the therapeutic applications of CAT; in the absence of which, clear aligners would continue to underperform clinically, due to their inherent biomechanical constraints. Finally, while innovations in aligner materials such as shape memory polymers, direct three-dimensional (3D) printed clear aligners and bioactive materials combined with clear aligner materials are essential to further advance the applications of CAT; increased awareness of environmental responsibilities among aligner manufacturers, aligner prescribing clinicians and aligner users is essential for better alignment of our climate change goals towards a sustainable planet.
Collapse
|
19
|
Xia Q, He Y, Jia L, Wang C, Wang W, Wang C, Song J, Fan Y. Assessment of labially impacted canines traction mode with clear aligners vs. fixed appliance: A comparative study based on 3D finite element analysis. Front Bioeng Biotechnol 2022; 10:1004223. [PMID: 36277381 PMCID: PMC9579379 DOI: 10.3389/fbioe.2022.1004223] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 09/21/2022] [Indexed: 12/05/2022] Open
Abstract
Purpose: The objective of this study was to evaluate and compare the biomechanical differences between clear aligner and fixed appliance in the traction of labially impacted canines based on 3D finite element analysis. Methods: A series of patient-oriented finite element models were constructed, including a maxillary dentition with a right labially canine, maxilla, periodontal ligaments, traction attachments, and clear aligners. The two most common clinical scenarios were investigated: Scenario A: impacted canine (distal) and Scenario B: impacted canine (mesial). For each clinical scenario, three traction models with clear aligners and one fixed appliance model were established. Results: In all four models, the impacted canines exhibited similar initial displacement tendencies of mesially rotated in Scenario A and distally rotated in Scenario B, and with small differences in periodontal ligament stress magnitude. However, the sum of the periodontal ligament stresses of the anchorage teeth in the clear aligner mode was in the range of 56.28–76.21 kPa and in the fixed appliance mode was in the range of 6.61–7.22 kPa. The maximum value of initial displacement of the anchorage teeth in the clear aligner mode was in the range of 13.71–19.72 μm, while in the fixed appliance mode was 3.10–3.92 μm. Conclusion: For impacted canines, clear aligner mode and fixed appliance mode have little difference in biomechanical effect. However, the anchorage teeth in the clear aligner mode endure higher stress and show a more pronounced displacement tendency. In addition, the biomechanical effects of different clear aligner traction models are various but not obvious.
Collapse
Affiliation(s)
- Qian Xia
- Stomatological Hospital of Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Yao He
- Stomatological Hospital of Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Lurong Jia
- Stomatological Hospital of Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Chunjuan Wang
- Stomatological Hospital of Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Weixu Wang
- Stomatological Hospital of Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Chao Wang
- Stomatological Hospital of Chongqing Medical University, Chongqing, China
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, Beijing, China
- *Correspondence: Jinlin Song, ; Chao Wang,
| | - Jinlin Song
- Stomatological Hospital of Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
- *Correspondence: Jinlin Song, ; Chao Wang,
| | - Yubo Fan
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, Beijing, China
| |
Collapse
|
20
|
Elshazly TM, Keilig L, Salvatori D, Chavanne P, Aldesoki M, Bourauel C. Effect of Trimming Line Design and Edge Extension of Orthodontic Aligners on Force Transmission: An in vitro Study. J Dent 2022; 125:104276. [PMID: 36055460 DOI: 10.1016/j.jdent.2022.104276] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 08/26/2022] [Accepted: 08/29/2022] [Indexed: 11/29/2022] Open
Abstract
OBJECTIVES To investigate how the stress distribution and forces transmitted from orthodontic aligners to the tooth surface are affected by the geometry and extension of the trimming line. MATERIALS AND METHODS Thirty-six aligners were thermoformed from Zendura FLX sheets (0.75 mm thick) and divided into four groups based on the design of the trimming line: Scalloped, Scalloped extended, Straight and Straight extended. Fuji pressure-sensitive films were used for pressure measurement. The pressurized films were scanned and evaluated. Pressures and forces were measured over the entire facial surface of an upper right central incisor (Tooth 11) and at 7 different locations [cervical, middle, incisal, mesio-incisal, mesio-cervical, disto-cervical, and disto-cervical]. In addition, the thickness of the aligners at these 7 sites was measured with a digital caliper. RESULTS The active force ranged from (2.2 - 6.9) N, and the average pressure was (1.6 - 2.7) MPa. The highest values were recorded for the (straight extended) design, while the lowest values were recorded for the scalloped design. The forces and stresses were not uniformly distributed over the surface. When the values in each area were compared separately, significant differences were found between the different designs in the cervical area, with the scalloped design transmitting the lowest cervical forces. Aligner thickness was drastically reduced (60-75% thinning) over the entire tooth surface after thermoforming. CONCLUSIONS The straight extended design of aligner's trimming line exhibited more uniform force transfer and stress distribution across the surface than the other designs. CLINICAL RELEVANCE The trimming line design could have a significant impact on the clinical outcome of orthodontic aligner treatment.
Collapse
Affiliation(s)
- Tarek M Elshazly
- Oral Technology, Dental School, University Hospital Bonn, Bonn, Germany.
| | - Ludger Keilig
- Oral Technology, Dental School, University Hospital Bonn, Bonn, Germany; Department of Dental Prosthetics, Propaedeutics and Materials Science, Dental School, University Hospital Bonn, Bonn, Germany
| | | | | | - Mostafa Aldesoki
- Oral Technology, Dental School, University Hospital Bonn, Bonn, Germany
| | | |
Collapse
|
21
|
Ye N, Brown B, Mantell S, Heo Y, Larson B, Fok A. Validation of finite element models for orthodontic aligners. J Mech Behav Biomed Mater 2022; 134:105404. [DOI: 10.1016/j.jmbbm.2022.105404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 07/20/2022] [Accepted: 07/26/2022] [Indexed: 10/16/2022]
|
22
|
Lahoud P, Jacobs R, Boisse P, EzEldeen M, Ducret M, Richert R. Precision medicine using patient-specific modelling: state of the art and perspectives in dental practice. Clin Oral Investig 2022; 26:5117-5128. [PMID: 35687196 DOI: 10.1007/s00784-022-04572-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Accepted: 05/30/2022] [Indexed: 12/25/2022]
Abstract
The dental practice has largely evolved in the last 50Â years following a better understanding of the biomechanical behaviour of teeth and its supporting structures, as well as developments in the fields of imaging and biomaterials. However, many patients still encounter treatment failures; this is related to the complex nature of evaluating the biomechanical aspects of each clinical situation due to the numerous patient-specific parameters, such as occlusion and root anatomy. In parallel, the advent of cone beam computed tomography enabled researchers in the field of odontology as well as clinicians to gather and model patient data with sufficient accuracy using image processing and finite element technologies. These developments gave rise to a new precision medicine concept that proposes to individually assess anatomical and biomechanical characteristics and adapt treatment options accordingly. While this approach is already applied in maxillofacial surgery, its implementation in dentistry is still restricted. However, recent advancements in artificial intelligence make it possible to automate several parts of the laborious modelling task, bringing such user-assisted decision-support tools closer to both clinicians and researchers. Therefore, the present narrative review aimed to present and discuss the current literature investigating patient-specific modelling in dentistry, its state-of-the-art applications, and research perspectives.
Collapse
Affiliation(s)
- Pierre Lahoud
- OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU, Leuven, Belgium.,Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.,Periodontology and Oral Microbiology, Department of Oral Health Sciences, KU Leuven, Leuven, Belgium
| | - Reinhilde Jacobs
- OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU, Leuven, Belgium.,Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.,Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden
| | - Philippe Boisse
- Laboratoire de Mécanique Des Contacts Et Structures, UMR 5259, CNRS/INSA, Villeurbanne, France
| | - Mostafa EzEldeen
- OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU, Leuven, Belgium.,Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.,Department of Oral Health Sciences, KU Leuven and Paediatric Dentistry and Special Dental Care, University Hospitals Leuven, Leuven, Belgium
| | - Maxime Ducret
- Hospices Civils de Lyon, PAM d'Odontologie, Lyon, France.,Faculty of Odontology, Lyon 1 University, Lyon, France.,Laboratoire de Biologie Tissulaire Et Ingénierie Thérapeutique, UMR5305 CNRS/UCBL, Lyon, France
| | - Raphael Richert
- Laboratoire de Mécanique Des Contacts Et Structures, UMR 5259, CNRS/INSA, Villeurbanne, France. .,Hospices Civils de Lyon, PAM d'Odontologie, Lyon, France. .,Faculty of Odontology, Lyon 1 University, Lyon, France.
| |
Collapse
|
23
|
Alhendi A, Khounganian R, Almudhi A. Cytotoxicity assessment of different clear aligner systems: An in vitro study. Angle Orthod 2022; 92:482482. [PMID: 35666210 PMCID: PMC9374349 DOI: 10.2319/121621-919.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Accepted: 04/01/2022] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVES To evaluate and compare the cytotoxicity of multiple clear aligner systems (Invisalign, Eon, SureSmile, and Clarity). MATERIALS AND METHODS A cytotoxicity assessment was carried out by immersing three sets of aligners from the included four systems in normal saline for 1 month at 37°C. The solutions were then diluted to three different concentrations (5%, 10%, and 20% volume/volume). Gingival fibroblasts were exposed to the solution after being seeded to 96-well microplates for 48 hours, and the medium was substituted with an MTT solution (MTT: 3-[4,5-dime- thylthiazol-2-yl]-2,5-diphenyltetrazolium bromide). Optical density was then measured to determine cell viability and evaluate cytotoxicity subsequently. RESULTS Cytotoxicity comparison showed no statistically significant difference among the four included systems. However, when cell viability of each system was compared with the control, a significant difference was reported at the 10% and 20% solution concentrations. The Clarity system had the lowest toxicity across all solution concentrations. CONCLUSIONS The thermoplastic materials used by all tested systems (Invisalign, Eon, SureSmile, and Clarity) presented some degree of toxicity (slight to moderate), with statistically significant mean differences compared with the control.
Collapse
|
24
|
Does Sex, Skeletal Class and Mandibular Asymmetry Affect Tooth Length and Asymmetry in Tooth Length? Symmetry (Basel) 2022. [DOI: 10.3390/sym14051069] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
Introduction: The aim of our cross-sectional study is to determine whether there is a link between sex, skeletal class and mandibular asymmetry in orthodontic patients, with tooth length and asymmetry in tooth length on contralateral sides of the mandible. Methods: As the source for relevant data to answer this question, 3D cone-beam tomography (CBCT) images of a total of 95 future orthodontic patients were retrospectively selected from private practice records and were analyzed. The CBCT images were part of routine orthodontic diagnosis. Patients were divided into three groups (Class I, Class III with asymmetry and Class III without asymmetry) based on skeletal variables assessed on orthodontic cephalometric images and frontal photos of the face. Three null hypotheses were developed, and a series of statistical tests was performed in order to support or reject them. Results: We have established that there exists a sexual dimorphism in some of the teeth’s lengths in our sample. Furthermore, we failed to find a link between mandibular asymmetry and asymmetry in tooth length. We have also found a link between skeletal class and tooth length differences in some of the analyzed measurements. Conclusions: Computational models used to design orthodontic appliances and to plan orthodontic treatment should be more individualized to consider a patient’s sex and skeletal class.
Collapse
|
25
|
Performance of Rigid and Soft Transfer Templates Using Viscous and Fluid Resin-Based Composites in the Attachment Bonding Process of Clear Aligners. Int J Dent 2022; 2022:1637594. [PMID: 35190741 PMCID: PMC8858075 DOI: 10.1155/2022/1637594] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2021] [Revised: 01/09/2022] [Accepted: 01/17/2022] [Indexed: 12/17/2022] Open
Abstract
Objectives The study aims at assessing the accuracy of the process of attachment bonding in aligner treatments. The analysis leads to the error estimation in the faithful reproduction of master model attachments using two types of transfer templates and two light-curing resin-based composites usually used in orthodontics. Methods The authors have used two transfer templates made of two different materials. The first, named Leone-biocompatible thermoforming material hard/soft, has a lower Young's modulus and is labelled as soft, while the other, named Leone-biocompatible thermoforming material, is marked as rigid. The resin-based composites possess different mechanical and rheological properties. Specifically, Transbondâ„¢ XT Light Cure Paste Adhesive, 3M has a higher viscosity than the TetricEvoflow, Ivoclar Vivadent, a flowable nanohybrid composite. The authors attempt to estimate the performance ranking between the four possible couples obtained by combining the two light-curing resin-based composites and transfer templates. Each combination was repeated in six models and compared with twelve master models, resulting in 36 total samples. A 3-D laser scanner is used to generate a digital model of each model. The comparison between digital models is the base for a comparative assessment in terms of relative and absolute error. The relative error is estimated using scalar performance indicators ranging from 0 to 1, where 1 indicates the optimum matching. The absolute error estimated from the mean square error between the coordinates of each digital model yields the reproduction accuracy in micrometer. Furthermore, the authors attempted to assess the error distribution by evaluating the point-by-point difference between the digital models. Results This analysis aims at localizing the sources of error in the considered models. The use of Transbondâ„¢ XT Light Cure Paste Adhesive, 3M with a rigid transfer template is always associated with significant accuracy and minor dispersion. However, in a few instances, using the soft template or the flowable resin-based composite can lead to bad performances. Significance. The data processing bestowed the following performance ranking from the first with lower reproduction error to the last characterized by the worst performance: (1) attachments bonding with rigid template and Transbondâ„¢ XT Light Cure Paste Adhesive, 3M, (2) attachments bonding with soft template and Transbondâ„¢ XT Light Cure Paste Adhesive, 3M, (3) attachments bonding with rigid template and TetricEvoflow, Ivoclar Vivadent, and (4) attachments bonding with soft template and TetricEvoflow, Ivoclar Vivadent.
Collapse
|
26
|
Liu L, Song Q, Zhou J, Kuang Q, Yan X, Zhang X, Shan Y, Li X, Long H, Lai W. The effects of aligner overtreatment on torque control and intrusion of incisors for anterior retraction with clear aligners: A finite-element study. Am J Orthod Dentofacial Orthop 2022; 162:33-41. [DOI: 10.1016/j.ajodo.2021.02.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 02/01/2021] [Accepted: 02/01/2021] [Indexed: 01/22/2023]
|
27
|
Upadhyay M, Arqub SA. Biomechanics of clear aligners: hidden truths & first principles. J World Fed Orthod 2021; 11:12-21. [PMID: 34965910 DOI: 10.1016/j.ejwf.2021.11.002] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Accepted: 11/23/2021] [Indexed: 11/19/2022]
Abstract
Over the past two decades clear aligner-based treatment has received remarkableattention from the orthodontic profession and more so from general practitioners.Different companies have emerged using vigorous advertisement to promote theirproducts mainly to patients and clinicians through social media. A variety of concepts,methods, and adjuncts have been introduced to enhance the efficacy andeffectiveness of clear aligners. However, the accuracy of tooth movement (vspredicted) with aligners still hovers around 50%. Fixed appliances fare much better onaccuracy and predictability of treatment. Why is there a discrepancy betweenexpected and actual outcomes? This paper utilizes 'first principles' and the existingevidence to unravel some of the key drawbacks of aligner-based therapy. Severalshortcomings in the biomechanical properties of aligner material (thermoplastics) thataffect clinical performance are discussed. Based on the first principles of alignerbiomechanics, this paper provides clinical insights for improving predictability and effectiveness of aligner therapy.
Collapse
Affiliation(s)
- Madhur Upadhyay
- Division of Orthodontics, University of Connecticut Health, Farmington, Connecticut, USA.
| | - Sarah Abu Arqub
- Division of Orthodontics, University of Connecticut Health, Farmington, Connecticut, USA
| |
Collapse
|
28
|
Martina S, Martini M, Bordegoni M, Razionale AV. Predictability of Root Movements Using Virtual Root Setup in a Patient With Periodontal Disease Treated With Clear Aligners. Open Dent J 2021. [DOI: 10.2174/1874210602115010605] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Aims:
The aim of the study was to show a case with a midline diastema in a patient with high periodontal risks and gingival recessions treated with clear
aligners. The objective was to predict and quantify root movements using a dedicated software that extrapolates data from the Cone Beam Computed Tomography (CBCT).
Case Presentation:
A 31-year-old female with a mandibular midline diastema asked for an aesthetic treatment. She had vertical bone loss on the lower central incisors, so a CBCT was necessary in order to plan the root movements. The purpose of the treatment was to avoid an uncontrolled tipping of the incisors and, therefore, a vestibular movement of the roots, which could cause serious periodontal problems.
Conclusion:
At the end of the treatment, the complete closure of the diastema and the radiographic healing of the vertical bone loss between mandibular central incisors were achieved. The superimpositions with the virtual setup demonstrated predictability of root movements of 76%.
Collapse
|
29
|
Liu L, Zhan Q, Zhou J, Kuang Q, Yan X, Zhang X, Shan Y, Li X, Lai W, Long H. Effectiveness of an anterior mini-screw in achieving incisor intrusion and palatal root torque for anterior retraction with clear aligners. Angle Orthod 2021; 91:794-803. [PMID: 34061964 DOI: 10.2319/120420-982.1] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 04/01/2021] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVES To analyze the biomechanical system of anterior retraction with clear aligner therapy (CAT) with and without an anterior mini-screw and elastics. MATERIALS AND METHODS Models including a maxillary dentition (without first premolars), maxilla, periodontal ligaments (PDLs), attachments, and aligners were constructed and imported to finite element software. Three model groups were created: (1) control (CAT alone), (2) labial elastics (CAT with elastics between the anterior mini-screw and buttons on central incisors), and (3) linguoincisal elastics (CAT with elastics between the anterior mini-screw and precision cuts on the lingual sides of the aligner). Elastic forces (0-300 g, in 50 g increments) were applied. RESULTS CAT alone caused lingual tipping and extrusion of the incisors. Labial elastics caused palatal root torquing and intrusion and mesial tipping of the central incisors, while linguoincisal elastics produced palatal root torquing and intrusion of both central and lateral incisors. Second premolars were intruded in all three groups, with less intrusion in the linguoincisal elastics group. For the control group, stress was concentrated on both labial and lingual root surfaces, alveolar ridge, and cervical and apical PDLs. Stress was more concentrated in the labial elastics group and less concentrated in the linguoincisal elastics group. CONCLUSIONS CAT produced lingual tipping and extrusion of incisors during anterior retraction. Anterior mini-screws and elastics can achieve incisor intrusion and palatal root torquing. Linguoincisal elastics are superior to labial elastics with a lower likelihood of buccal open bite. Root resorption and alveolar defects may occur in CAT, more likely for labial elastics and less likely for linguoincisal elastics.
Collapse
|
30
|
Li R, She W, Luo Y, Wang J, Peng Y, Ye Q. The optimal activation of plastic aligner for canine distal movement: a three-dimensional finite element analysis. Odontology 2021; 110:305-312. [PMID: 34626315 DOI: 10.1007/s10266-021-00663-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Accepted: 09/29/2021] [Indexed: 10/20/2022]
Abstract
This study aimed to investigate the optimal activation of plastic aligner for the canine distal movement by combining the stress and strain of periodontal ligament. Computer-aided design models of the upper canine, periodontal ligament, alveolar bone, and plastic aligner were constructed. The stresses and strains of periodontal ligament were acquired by fitting plastic aligner on the canine, which will cause the canine distal-direction movement. The activation of plastic aligner was set into 12 groups, including 0.050, 0.100, 0.125, 0.150, 0.175, 0.200, 0.225, 0.250, 0.275, 0.300, 0.350, and 0.400Â mm. Assuming the volume-averaged hydrostatic stress (VAHS) ranging from 4.7 to 16Â kPa to be the optimal stress, and an average strain no less than 0.3 to be the optimal strain. The optimal activation of plastic aligner was acquired based on the optimal stress and average strain. As the activation increased, the stress and strain of periodontal ligament increased visibly. The degree of activation of plastic aligner was nonlinearly and positively related to VAHS and average strain. According to the fitted curves, the activation corresponding to the optimal stress was 0.07-0.24Â mm and the activation was not less than 0.21Â mm based on the optimal strain. The optimal activation of plastic aligner for the canine distal movement was 0.21-0.24Â mm in this study. The degree of activation affects the force system of orthodontic tooth movement, and it should be taken into consideration to obtain healthy and efficient tooth movement. The activation with 0.21-0.24Â mm seems optimal for orthodontic tooth movement in the plastic aligner system in this study.
Collapse
Affiliation(s)
- Ruohan Li
- Renmin Hospital of Wuhan University, Wuhan, Hubei, China
| | - Wenting She
- Renmin Hospital of Wuhan University, Wuhan, Hubei, China
| | - Yu Luo
- Renmin Hospital of Wuhan University, Wuhan, Hubei, China
| | - Juan Wang
- Renmin Hospital of Wuhan University, Wuhan, Hubei, China
| | - Youjian Peng
- Renmin Hospital of Wuhan University, Wuhan, Hubei, China.
| | - Qingsong Ye
- Renmin Hospital of Wuhan University, Wuhan, Hubei, China.
- Massachusetts General Hospital, Harvard School of Dental Medicine, Boston, MA, USA.
| |
Collapse
|
31
|
Effects of Variable Composite Attachment Shapes in Controlling Upper Molar Distalization with Aligners: A Nonlinear Finite Element Study. JOURNAL OF HEALTHCARE ENGINEERING 2021; 2021:5557483. [PMID: 34457219 PMCID: PMC8397573 DOI: 10.1155/2021/5557483] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/27/2021] [Revised: 06/20/2021] [Accepted: 08/07/2021] [Indexed: 11/17/2022]
Abstract
The objective of the present study is to describe the stress and displacement patterns created by clear aligners and composite attachments bonded with the acid-etch technique on the labial surface of the maxillary first upper molar during its distalization. Maxillary molar distalization is a clinical orthodontics procedure used to move the first maxillary molar distally. The procedure is useful in patients with some Class II malocclusion allowing the first molar to move into a Class I relationship and the correction of associated malocclusion features. Three finite element models were designed to simulate the alveolar bone, molar tooth, periodontal ligament, aligner, and composite attachments. The first model had no composite attachment, the second model had a vertical rectangular attachment, and the third model had a newly designed attachment. A loading method was developed that mimicked the aligner's molar distal movement. PDL was set as a viscoelastic material with a nonlinear mechanical response. von Mises and maximum principal stresses and tooth displacement patterns were analyzed using dedicated software. All the configurations showed some form of clockwise rotation in addition to the distal movement. The crown portion of the tooth showed maximum displacement in all three models; however, in the absence of attachment, the root apex moved in the opposite direction which was compatible with uncontrolled tipping movement. Simulations with attachments exhibited the best performance regarding the movement patterns. The third group, with the newly designed attachment, exhibited the best performance concerning stress distribution (principal stress and von Mises stresses) and higher stresses in the periodontal ligament and tooth. Incorporating a vertical rectangular attachment in a clear aligner resulted in the reduction of mesiodistal tipping tendency during molar distalization. The third model was the most efficient considering both displacement pattern and stress distribution. The level of stress generated by the third model needs to be further investigated in future studies.
Collapse
|
32
|
Efficient Design of a Clear Aligner Attachment to Induce Bodily Tooth Movement in Orthodontic Treatment Using Finite Element Analysis. MATERIALS 2021; 14:ma14174926. [PMID: 34501017 PMCID: PMC8433704 DOI: 10.3390/ma14174926] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 08/27/2021] [Accepted: 08/27/2021] [Indexed: 01/31/2023]
Abstract
Clear aligner technology has become the preferred choice of orthodontic treatment for malocclusions for most adult patients due to their esthetic appeal and comfortability. However, limitations exist for aligner technology, such as corrections involving complex force systems. Composite attachments on the tooth surface are intended to enable active control of tooth movements. However, unintended tooth movements still occur. In this study, we present an effective attachment design of an attachment that can efficiently induce tooth movement by comparing and analyzing the movement and rotation of teeth between a general attachment and an overhanging attachment. The 3D finite element modes were constructed from CBCT data and used to analyze the distal displacement of the central incisor using 0.5- and 0.75-mm-thick aligners without an attachment, and with general and overhanging attachments. The results show that the aligner with the overhanging attachment can effectively reduce crown tipping and prevent axial rotation for an intended distal displacement of the central incisor. In all models, an aligner with or without attachments was not capable of preventing the lingual inclination of the tooth.
Collapse
|
33
|
TAD's for the Derotation of 90° Rotated Maxillary Bicuspids. Case Rep Dent 2021; 2021:4285330. [PMID: 34367699 PMCID: PMC8342153 DOI: 10.1155/2021/4285330] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Accepted: 07/19/2021] [Indexed: 11/28/2022] Open
Abstract
It is undeniable that the advent of extra-alveolar mini-implants for anchorage purposes has revolutionized the field of Orthodontics. This case report sheds light on an innovative anchorage plan using TADs, to carry out treatment for a 15-year-old female patient. The patient reported to the clinic with a chief complaint of rotated second premolars, crowding, and a deep bite. On examination, it was seen that the patient had a Class I skeletal pattern, Class II subdivision molar relationship, 90-degree maxillary second premolar rotations, crowding in both the arches, and a deep bite. In this case, the clinicians decided to use TADs for premolar derotation as it not only provides a pure rotational couple without any deleterious effects on the adjacent teeth but also helps shorten the overall treatment time. The total treatment time for this case was 10 months.
Collapse
|
34
|
Direct 3D Printing of Clear Orthodontic Aligners: Current State and Future Possibilities. MATERIALS 2021; 14:ma14071799. [PMID: 33916462 PMCID: PMC8038630 DOI: 10.3390/ma14071799] [Citation(s) in RCA: 67] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Revised: 03/26/2021] [Accepted: 04/02/2021] [Indexed: 02/07/2023]
Abstract
The recent introduction of three-dimensional (3D) printing is revolutionizing dentistry and is even being applied to orthodontic treatment of malocclusion. Clear, personalized, removable aligners are a suitable alternative to conventional orthodontic appliances, offering a more comfortable and efficient solution for patients. Including improved oral hygiene and aesthetics during treatment. Contemporarily, clear aligners are produced by a thermoforming process using various types of thermoplastic materials. The thermoforming procedure alters the properties of the material, and the intraoral environment further modifies the properties of a clear aligner, affecting overall performance of the material. Direct 3D printing offers the creation of highly precise clear aligners with soft edges, digitally designed and identically reproduced for an entire set of treatment aligners; offering a better fit, higher efficacy, and reproducibility. Despite the known benefits of 3D printing and the popularity of its dental applications, very limited technical and clinical data are available in the literature about directly printed clear aligners. The present article discusses the advantages of 3D printed aligners in comparison to thermoformed ones, describes the current state of the art, including a discussion of the possible road blocks that exist such as a current lack of approved and marketed materials and limited existence of aligner specific software. The present review suggests the suitability of 3D direct printed aligners is superior to that of thermoformed manufactured aligners because of the prior’s increased accuracy, load resistance, and lower deformation. It is an overall more stable way to produce an aligner where submillimeter movements can make a difference in treatment outcome. Direct 3D printing represents a complex method to control the thickness of the aligner and therefore has a better ability to control the force vectors that are used to produce tooth movement. There is currently no other approved material on the market that can do this. The conclusion of this article is that we encourage further in vitro and in vivo studies to test these new technologies and materials.
Collapse
|
35
|
Ho CT, Huang YT, Chao CW, Huang TH, Kao CT. Effects of different aligner materials and attachments on orthodontic behavior. J Dent Sci 2021; 16:1001-1009. [PMID: 34141116 PMCID: PMC8189899 DOI: 10.1016/j.jds.2021.01.011] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Revised: 01/25/2021] [Indexed: 12/02/2022] Open
Abstract
Background/purpose The orthodontic aligner becomes popular worldwide in orthodontic therapy as an esthetic alternative to fixed labial braces. This study evaluated orthodontic tooth movement behavior using different aligner materials and attachment shapes for the movement of a single tooth. Materials and methods First bicuspid extracted resin typodont models were printed with a 3D printer. Three type of attachments, an ellipsoid shape (thick and thin) and a bar, were designed to fit the canine crown surface. Three types of aligner materials, Polyethylene Terephthalate enhanced with glycol (BIOSTAR) Polyethylene Terephthalate (BenQ), and Thermoplastic polyurethanes (TPU) were used to fabricate different aligners. The typodonts with aligners were sunk in a water bath to simulate canine distal movement in vivo. The canine crown, root movement, and long axis angle changes in each step were calculated and recorded. The data were analysed using a oneway ANOVA statistical method. Results Comparing the three aligners, the changes the long axis of the canine showed that the BENQ group had a smaller change in the long axis angle. The BENQ group canine involved bodily movement, but the canine movement of the BIOSTAR and TPU group involved tipping. Comparing the three attachments, the bar type attachment had more canine crown tipping in the BIOSTAR and TPU groups. The thick and thin ellipsoid-shaped attachments showed no statistical differences in tooth movement. Conclusion Attachment shape or size had little influence on the bodily movement of the tooth. A high modulus material may thus be suitable for clinical applications.
Collapse
Affiliation(s)
- Chung-Te Ho
- School of Dentistry, College of Oral Medicine, Chung Shan Medical University, Department of Orthodontics, Chung Shan Medical University Hospital, Taichung, Taiwan
| | - Yun-Ting Huang
- Department of Dentistry, Chung Shan Medical University. Hospital, Taichung, Taiwan
| | - Chien-Wei Chao
- Department of Dentistry, Chung Shan Medical University. Hospital, Taichung, Taiwan
| | - Tsui-Hsine Huang
- Department of Dentistry, Chung Shan Medical University. Hospital, Taichung, Taiwan
| | - Chia-Tze Kao
- School of Dentistry, College of Oral Medicine, Chung Shan Medical University, Department of Orthodontics, Chung Shan Medical University Hospital, Taichung, Taiwan
| |
Collapse
|
36
|
Oliveira PLE, Campos V, de Andrade RM, de Souza Araújo MT, Pithon MM, Sant'Anna EF. Deformation of the circummaxillary sutures during acute micro-implant assisted rapid palatal expansion and tooth-supported expansion: An ex vivo study. Orthod Craniofac Res 2020; 24:396-404. [PMID: 33277817 DOI: 10.1111/ocr.12450] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Revised: 11/26/2020] [Accepted: 11/30/2020] [Indexed: 11/30/2022]
Abstract
INTRODUCTION This study aimed to assess and compare the deformation that develops in the circummaxillary sutures during activation of micro-implant assisted rapid palatal expander (MARPE) and tooth-supported expander (Hyrax) s, in the rapid maxillary expansion. SETTINGS AND SAMPLE 7 pigs Sus Scrofa received custom-made MARPE (n = 3) and Hyrax (n = 4) appliances. MATERIAL AND METHODS The devices were activated 25 times with strain readings captured by strain gauges attached to the following regions: posterior midpalatal suture (MPS), maxilla-premaxilla suture (MPM), maxilla-zygomatic suture (MZ) and maxilla pterygoid-process suture (MPP). The intermolar distance and suture width were measured immediately before activation and at the 20th and 25th activation. ANOVA and Kruskal-Wallis test was applied. RESULTS The MARPE group presented greater MPS displacement in all measured regions, and one of the devices produced a significant opening (1.7 mm) in the posterior region. The accumulated tension in the MPS was higher compared to the other sutures (P < .05). A MARPE animal presented higher median tension in the MPS region (294.77με) compared to all other animals except one Hyrax animal (P < .05). Regarding the median tensions of the different activation intervals, the median tension measured during the 16th to 25th activation interval in the Hyrax group was lower than that measured during the first 8 activations, in both the MPS and MZ (P < .05). CONCLUSIONS MARPE expanders developed more constant tensions during all activations (MPS and MZ), while Hyrax showed lower tension in the 16th to 25th activation.
Collapse
Affiliation(s)
- Pedro Lima Emmerich Oliveira
- Department of Orthodontics and Pediatric Dentistry, Universidade Federal do Rio de Janeiro, UFRJ, Rio de Janeiro, Brazil
| | - Vinicius Campos
- Department of Mechanical Engineering, Universidade Federal do EspÃrito Santo, UFES, Vitoria, Brazil
| | | | - Mônica Tirre de Souza Araújo
- Department of Orthodontics and Pediatric Dentistry, Universidade Federal do Rio de Janeiro, UFRJ, Rio de Janeiro, Brazil
| | - Matheus Melo Pithon
- Department of Orthodontics and Pediatric Dentistry, Universidade Estadual do Sudoeste da Bahia, UESB, Jequié, Brazil
| | - Eduardo Franzotti Sant'Anna
- Department of Orthodontics and Pediatric Dentistry, Universidade Federal do Rio de Janeiro, UFRJ, Rio de Janeiro, Brazil
| |
Collapse
|
37
|
Jindal P, Worcester F, Siena FL, Forbes C, Juneja M, Breedon P. Mechanical behaviour of 3D printed vs thermoformed clear dental aligner materials under non-linear compressive loading using FEM. J Mech Behav Biomed Mater 2020; 112:104045. [DOI: 10.1016/j.jmbbm.2020.104045] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 08/13/2020] [Accepted: 08/14/2020] [Indexed: 12/19/2022]
|
38
|
Upper Second Molar Distalization with Clear Aligners: A Finite Element Study. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10217739] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Among orthodontists and scientists, in the last years, upper molar distalization has been a debated topic in the orthodontic aligner field. However, despite that few clinical studies have been published, no insights on aligners’ biomechanics regarding this movement are available. The aim of this study was to assess, through finite element analysis, the force system resulting in the upper arch during second maxillary molar distalization with clear aligners and variable attachments settings. The average tooth distalization was found to be 0.029, with buccal flaring of the upper incisors in all attachment configurations. The mesial deformation of the aligner was registered to be 0.2 mm on average. Different pressure areas on the interface between aligners and upper molars were registered, with the mesial attachment surface to be directly involved when present. Periodontal ligament pressure was reported to range between 67 g/cm2 and 132 g/cm2. Configurations with rectangular attachments from second molar-to-canine and from first molar-to-canine present, in an in silico environment, almost equal efficiency in distalizing the upper second molar. However, attachments from the second molar to the canine are suggested to be adopted in clinical environments due to greater feasibility in everyday practice.
Collapse
|
39
|
Costa R, Calheiros FC, Ballester RY, Gonçalves F. Effect of three different attachment designs in the extrusive forces generated by thermoplastic aligners in the maxillary central incisor. Dental Press J Orthod 2020; 25:46-53. [PMID: 32844975 PMCID: PMC7437153 DOI: 10.1590/2177-6709.25.3.046-053.oar] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2018] [Accepted: 05/26/2019] [Indexed: 12/21/2022] Open
Abstract
INTRODUCTION Orthodontic aligners use have increased in dentistry. The resolution of complex movements such as extrusion demands the use of attachments to reach the aimed force, but just a few studies have been developed to evaluate the biomechanical performance of the aligners and their accessories. OBJECTIVE The objective of this study was to evaluate on the three axes (X, Y and Z) the forces generated by three different attachment designs for the extrusion of the maxillary central incisor using esthetic orthodontic aligners. METHODS Three prototypes of maxillary models were developed, each one with a specific attachment inserted in the central incisor. Three aligners were manufactured for each of the three attachment designs, with 0.33-mm activation in the direction of the extrusion. An analytical device was used to evaluate the forces applied to the three axes by each aligner/attachment. The data were assessed by one-way ANOVA and Tukey's test (α = 0.05). RESULTS All of the studied attachment designs could satisfactorily perform the extrusion movement. However, force intensities were different in the three designs (design 1 = 2.5 N; design 2 = 2.2 N, and design 3 = 1.1 N). Furthermore, two of the three attachment designs (designs 1 and 2) eventually exerted significant forces on the X (mesiodistal) and Y (buccopalatal) axes. CONCLUSION The attachment design 3 presents the best distribution of forces for extrusion movement, generating almost null forces on X and Y axes, and lower intensity of force on the Z axis.
Collapse
Affiliation(s)
- Rafael Costa
- Faculdade de Odontologia, Universidade Ibirapuera, São Paulo, SP, Brazil
| | | | | | - Flávia Gonçalves
- Faculdade de Odontologia, Universidade Ibirapuera, São Paulo, SP, Brazil
| |
Collapse
|
40
|
Jiang T, Wu RY, Wang JK, Wang HH, Tang GH. Clear aligners for maxillary anterior en masse retraction: a 3D finite element study. Sci Rep 2020; 10:10156. [PMID: 32576935 PMCID: PMC7311544 DOI: 10.1038/s41598-020-67273-2] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2019] [Accepted: 06/04/2020] [Indexed: 11/23/2022] Open
Abstract
To evaluate tooth behaviours under various maxillary incisor retraction protocols for clear aligner therapy. A three-dimensional finite element model of maxillary dentition was constructed for first premolar extraction. A loading method was developed to mimic the mode of action of clear aligners for incisor en masse retraction. Three protocols with different amounts of retraction and intrusion on incisors were designed. Initial tooth displacements and stresses on periodontal ligaments were analysed with ANSYS software. The central (U1) and lateral (U2) incisors exhibited uncontrolled lingual tipping and extrusion upon 0.25 mm retraction. U1 exhibited translation movement, while U2 underwent less tipping during 0.2 mm retraction and 0.15 mm intrusion. Labial tipping and intrusion of U1 and bodily intrusion of U2 were observed during 0.1 mm of retraction and 0.23 mm of intrusion. With the additional intrusion on incisors, canine showed extrusion movement, and higher stresses on periodontal ligaments were shifted from U2 to canines. Incisors also exhibited different mesial-distal angulation in the three simulations, while posterior teeth all suffered mesial inclination. Incorporating intrusion displacement in clear aligners led to a tendency of lingual root movement during incisor retraction. The complexity of tooth movement should be recognized regarding clear aligner therapy.
Collapse
Affiliation(s)
- Ting Jiang
- Department of Orthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China
| | - Rui Ying Wu
- Department of Orthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China
| | - Jian Kai Wang
- Department of Orthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China
| | - Hong Hong Wang
- Department of Orthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China.,National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, 200011, China
| | - Guo Hua Tang
- Department of Orthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China. .,National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, 200011, China.
| |
Collapse
|
41
|
Tamer İ, Öztaş E, Marşan G. Orthodontic Treatment with Clear Aligners and The Scientific Reality Behind Their Marketing: A Literature Review. Turk J Orthod 2019; 32:241-246. [PMID: 32110470 DOI: 10.5152/turkjorthod.2019.18083] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2018] [Accepted: 03/20/2019] [Indexed: 11/22/2022]
Abstract
As the demand for esthetic treatments is increasing, more people are seeking alternatives to fixed orthodontic appliances. Clear aligners are an esthetic and comfortable option for orthodontic treatment and have gained immense popularity over the last decade. This review will highlight the increasing popularity of clear aligners by describing some aligner systems frequently used today. The scope, limitations, effectiveness, efficacy, and stability of treatment results achieved with this method will be discussed. Further, this paper will assess the possible side effects caused by clear aligner treatment.
Collapse
Affiliation(s)
- Ä°pek Tamer
- Department of Orthodontics, Ä°stanbul University Ä°stanbul School of Dentistry, Ä°stanbul, Turkey
| | - Evren Öztaş
- Department of Orthodontics, Ä°stanbul University Ä°stanbul School of Dentistry, Ä°stanbul, Turkey
| | - Gülnaz Marşan
- Department of Orthodontics, Ä°stanbul University Ä°stanbul School of Dentistry, Ä°stanbul, Turkey
| |
Collapse
|
42
|
Cortona A, Rossini G, Parrini S, Deregibus A, Castroflorio T. Clear aligner orthodontic therapy of rotated mandibular round-shaped teeth: A finite element study. Angle Orthod 2019; 90:247-254. [PMID: 31469592 DOI: 10.2319/020719-86.1] [Citation(s) in RCA: 59] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
OBJECTIVE To evaluate, using the finite element method, the orthodontic rotational movement of a lower second premolar obtained with clear aligners, analyzing different staging and attachment configurations. MATERIALS AND METHODS A CAD model including a complete lower dental arch (with element 4.5 mesially rotated 30°) and the corresponding periodontal ligaments, attachments, and aligner was designed and imported to finite element software. Starting from the CAD model, six projects were created to simulate the following therapeutic combinations for correcting element 4.5 position: (1) without attachments, (2) single attachment placed on the buccal surface of element 4.5, (3) three attachments placed on the buccal surfaces of teeth 4.4 to 4.6. For each project, both 1.2° and 3° of aligner activation were considered. RESULTS All the analyzed configurations revealed a clockwise rotation movement of element 4.5 on the horizontal plane. Models with attachments showed a greater tooth displacement pattern than models without attachments. Simulations with attachments and 3° of aligner activation exhibited the best performance concerning tooth movement but registered high stresses in the periodontal ligaments, far from the ideal stress levels able to produce tooth rotational movement. CONCLUSIONS The model with a single attachment and 1.2° of aligner activation was the most efficient, followed by the three attachment model with the same degree of activation. Aligner activation should not exceed 1.2° to achieve better control of movement and reasonable stress in periodontal structures.
Collapse
|
43
|
Biomechanical Effects of Different Auxiliary-Aligner Designs for the Extrusion of an Upper Central Incisor: A Finite Element Analysis. JOURNAL OF HEALTHCARE ENGINEERING 2019; 2019:9687127. [PMID: 31485303 PMCID: PMC6702849 DOI: 10.1155/2019/9687127] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2018] [Revised: 03/06/2019] [Accepted: 07/18/2019] [Indexed: 11/25/2022]
Abstract
Aim To evaluate the biomechanical effects of four different auxiliary-aligner combinations for the extrusion of a maxillary central incisor and to define the most effective design through finite element analysis (FEA). Materials and Methods A full maxillary arch (14 teeth) was modelled by combining two different imaging techniques: cone beam computed tomography and surface-structured light scan. The appliance and auxiliary element geometries were created by exploiting computer-aided design (CAD) procedures. The reconstructed digital models were imported within the finite element solver (Ansys® 17). For the extrusion movement, the authors compared the aligner without an attachment with three auxiliary-aligner designs: a rectangular palatal attachment, a rectangular buccal attachment, and an ellipsoid buccal attachment. The resulting force-moment (MF) system delivered by the aligner to the target tooth and the tooth displacement were calculated for each scenario. Results The maximum tooth displacement along the z-axis (0.07 mm) was obtained with the rectangular palatal attachment, while the minimum (0.02 mm) was obtained without any attachments. With the ellipsoid attachment, the highest undesired moments Mx and My were found. The rectangular palatal attachment showed the highest Fz (2.0 N) with the lowest undesired forces (Fx = 0.4 N; Fy = −0.2 N). Conclusions FEA demonstrated that the rectangular palatal attachment can improve the effectiveness of the appliance for the extrusion of an upper central incisor.
Collapse
|
44
|
Zhou X, Gan Y, Zhao Q, Xiong J, Xia Z. Simulation of orthodontic force of archwire applied to full dentition using virtual bracket displacement method. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2019; 35:e3189. [PMID: 30790479 DOI: 10.1002/cnm.3189] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2018] [Revised: 10/31/2018] [Accepted: 02/16/2019] [Indexed: 06/09/2023]
Abstract
OBJECTIVE Orthodontic force simulation of tooth provides important guidance for clinical orthodontic treatment. However, previous studies did not involve the simulation of orthodontic force of archwire applied to full dentition. This study aimed to develop a method to simulate orthodontic force of tooth produced by loading a continuous archwire to full dentition using finite element method. METHOD A three-dimensional tooth-periodontal ligament-bone complex model of mandible was reconstructed from computed tomography images, and models of brackets and archwire were built. The simulation was completed through two steps. First, node displacements of archwire before and after loading were estimated through moving virtual brackets to drive archwire deformation. Second, the obtained node displacements were loaded to implement the loading of archwire, and orthodontic force was calculated. An orthodontic force tester (OFT) was used to measure orthodontic force in vitro for the validation. RESULTS After the simulation convergence, archwire was successfully loaded to brackets, and orthodontic force of teeth was obtained. Compared with the measured orthodontic force using the OFT, the absolute difference of the simulation results ranged from 0.5 to 22.7 cN for force component and ranged from 2.2 to 80.0 cN•mm for moment component, respectively. The relative difference of the simulation results ranged from 2.5% to 11.0% for force component, and ranged from 0.6% to 14.7% for moment component, respectively. CONCLUSIONS The developed orthodontic force simulation method based on virtual bracket displacement can be used to simulate orthodontic force provided by the archwire applied to full dentition.
Collapse
Affiliation(s)
- Xinwen Zhou
- Department of Automation, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China
| | - Yangzhou Gan
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, People's Republic of China
- CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology, Shenzhen, 518055, People's Republic of China
| | - Qunfei Zhao
- Department of Automation, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China
| | - Jing Xiong
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, People's Republic of China
| | - Zeyang Xia
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, People's Republic of China
- CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology, Shenzhen, 518055, People's Republic of China
| |
Collapse
|
45
|
Barone S, Neri P, Paoli A, Razionale AV. Design and manufacturing of patient-specific orthodontic appliances by computer-aided engineering techniques. Proc Inst Mech Eng H 2017; 232:54-66. [PMID: 29160155 DOI: 10.1177/0954411917742945] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Orthodontic treatments are usually performed using fixed brackets or removable oral appliances, which are traditionally made from alginate impressions and wax registrations. Among removable devices, eruption guidance appliances are used for early orthodontic treatments in order to intercept and prevent malocclusion problems. Commercially available eruption guidance appliances, however, are symmetric devices produced using a few standard sizes. For this reason, they are not able to meet all the specific patient's needs since the actual dental anatomies present various geometries and asymmetric conditions. In this article, a computer-aided design-based methodology for the design and manufacturing of a patient-specific eruption guidance appliances is presented. The proposed approach is based on the digitalization of several steps of the overall process: from the digital reconstruction of patients' anatomies to the manufacturing of customized appliances. A finite element model has been developed to evaluate the temporomandibular joint disks stress level caused by using symmetric eruption guidance appliances with different teeth misalignment conditions. The developed model can then be used to guide the design of a patient-specific appliance with the aim at reducing the patient discomfort. At this purpose, two different customization levels are proposed in order to face both arches and single tooth misalignment issues. A low-cost manufacturing process, based on an additive manufacturing technique, is finally presented and discussed.
Collapse
Affiliation(s)
- Sandro Barone
- Department of Civil and Industrial Engineering, University of Pisa, Pisa, Italy
| | - Paolo Neri
- Department of Civil and Industrial Engineering, University of Pisa, Pisa, Italy
| | - Alessandro Paoli
- Department of Civil and Industrial Engineering, University of Pisa, Pisa, Italy
| | | |
Collapse
|