1
|
Harper CE, Hudson JS, Tidwell K, Boswell R, Yong HL, Maxwell AJ. Implementation of the first comprehensive state oral fluid drug testing program for roadside screening and laboratory testing in DUID cases-A 5-year review. J Anal Toxicol 2023; 47:694-702. [PMID: 37526020 DOI: 10.1093/jat/bkad051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 06/07/2023] [Accepted: 07/31/2023] [Indexed: 08/02/2023] Open
Abstract
Oral fluid (OF) is a valuable specimen for driving under the influence of drugs (DUID) applications. This study demonstrates the implementation of the first comprehensive OF drug testing program in the United States, including approved roadside screening OF devices for law enforcement and validated liquid chromatography-tandem mass spectrometry (LC-MS-MS) confirmation methods. Three roadside OF screening devices were evaluated: the Dräger DrugTest® 5000, Abbott SoToxa®, and Randox Evidence MultiSTAT™. Two qualitative LC-MS-MS confirmation methods were validated per ASB Standard 036. The first method utilized an automated dispersive pipette extraction extraction using Integra and Hamilton STARlet platforms for drugs of abuse. The second method used a liquid-liquid extraction to detect cannabinoids. The prevalence of drugs in blood and OF was monitored over 5 years of casework. Calibration curves were analyzed with each batch to monitor OF concentrations for research purposes. Three roadside OF screening devices were deemed fit for purpose. Devices demonstrated appropriate sensitivity, specificity, positive and negative predictive values, and accuracy above 80% for targeted drugs except for benzodiazepines (DrugTest® 5000) and amphetamine (SoToxa®). The validated LC-MS-MS OF confirmation methods met the National Safety Council-recommended cutoffs for 18/21 (86%) of the targets. Over 5 years of casework, THC and cocaine were detected at a positivity rate of 90% and 97% in OF versus 75% and 44% in blood, respectively. OF:blood ratios exceeded unity for parent drugs. Median concentrations of THC in OF and blood were 31 and 3.5 ng/mL, respectively. OF is a viable alternative or supplemental specimen for DUID investigations. Collecting OF close to the driving event increases the opportunity to identify pharmacologically active substances, and when combined with blood analysis results, an elevated OF:blood ratio provides valuable information for DUID investigation purposes.
Collapse
Affiliation(s)
- Curt E Harper
- Alabama Department of Forensic Sciences, 2026 Valleydale Rd, Hoover, AL 35244, USA
| | - Jason S Hudson
- Quest Diagnostics, 10101 Renner Blvd, Lenexa, KS 66219, USA
| | - Kristin Tidwell
- Alabama Department of Forensic Sciences, 2026 Valleydale Rd, Hoover, AL 35244, USA
| | - Rebekah Boswell
- Alabama Department of Forensic Sciences, 2026 Valleydale Rd, Hoover, AL 35244, USA
| | - Hui Liu Yong
- Alabama Department of Forensic Sciences, 2026 Valleydale Rd, Hoover, AL 35244, USA
| | - Antoinette J Maxwell
- Alabama Department of Forensic Sciences, 2026 Valleydale Rd, Hoover, AL 35244, USA
| |
Collapse
|
2
|
Positivity to Cocaine and/or Benzoylecgonine in Confirmation Analyses for On-Road Tests in Spain. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18105371. [PMID: 34070008 PMCID: PMC8157855 DOI: 10.3390/ijerph18105371] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 05/13/2021] [Accepted: 05/15/2021] [Indexed: 11/16/2022]
Abstract
We are using real-life data in order to determine the prevalence of driving with the presence of cocaine and/or benzoylecgonine (BZE), their concentrations, and their use in combination with other drugs. This study assessed data on Spanish drivers with confirmed drug-positive results recorded by the Spanish National Traffic Agency from 2011-2016. Frequencies of positivity for cocaine and/or BZE and concentration of such substances were obtained. Comparisons and univariate and multivariate regression analyses were performed. Drivers who tested positive for cocaine and/or BZE accounted for 48.59% of the total positive results for drugs. In positive cases for both cocaine and BZE, other substances were detected in 81.74%: delta-9-tetrahydrocannabinol (THC) (68.19%), opioids (20.78%) and amphetamine-like substances (16.76%). In the multivariate logistic regression analysis, the frequency of cocaine and/or BZE positive cases decreased with age (OR:0.97) and were less likely among women (OR:0.63). Concentrations (ng/mL) of cocaine (249.30) and BZE (137.90) were higher when both substances were detected together than when detected alone. Positivity to cocaine represented an important proportion among Spanish drivers who tested positive for drugs, and polysubstance use was especially observed in more than 8 out of 10 positive cases for cocaine and/or BZE.
Collapse
|
3
|
Scherer J, Schuch J, Rabelo-da-Ponte F, Silvestrin R, Ornell R, Sousa T, Limberger R, Pechansky F. Analytical reliability of four oral fluid point-of-collection testing devices for drug detection in drivers. Forensic Sci Int 2020; 315:110434. [DOI: 10.1016/j.forsciint.2020.110434] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Revised: 07/20/2020] [Accepted: 07/22/2020] [Indexed: 12/21/2022]
|
4
|
Jones NS, Comparin JH. Interpol review of controlled substances 2016-2019. Forensic Sci Int Synerg 2020; 2:608-669. [PMID: 33385148 PMCID: PMC7770462 DOI: 10.1016/j.fsisyn.2020.01.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 01/23/2020] [Indexed: 12/14/2022]
Abstract
This review paper covers the forensic-relevant literature in controlled substances from 2016 to 2019 as a part of the 19th Interpol International Forensic Science Managers Symposium. The review papers are also available at the Interpol website at: https://www.interpol.int/content/download/14458/file/Interpol%20Review%20Papers%202019.pdf.
Collapse
Affiliation(s)
- Nicole S. Jones
- RTI International, Applied Justice Research Division, Center for Forensic Sciences, 3040 E. Cornwallis Road, Research Triangle Park, NC, 22709-2194, USA
| | - Jeffrey H. Comparin
- United States Drug Enforcement Administration, Special Testing and Research Laboratory, USA
| |
Collapse
|
5
|
Desrosiers NA, Huestis MA. Oral Fluid Drug Testing: Analytical Approaches, Issues and Interpretation of Results. J Anal Toxicol 2019; 43:415-443. [DOI: 10.1093/jat/bkz048] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 05/12/2019] [Accepted: 05/23/2019] [Indexed: 12/19/2022] Open
Abstract
AbstractWith advances in analytical technology and new research informing result interpretation, oral fluid (OF) testing has gained acceptance over the past decades as an alternative biological matrix for detecting drugs in forensic and clinical settings. OF testing offers simple, rapid, non-invasive, observed specimen collection. This article offers a review of the scientific literature covering analytical methods and interpretation published over the past two decades for amphetamines, cannabis, cocaine, opioids, and benzodiazepines. Several analytical methods have been published for individual drug classes and, increasingly, for multiple drug classes. The method of OF collection can have a significant impact on the resultant drug concentration. Drug concentrations for amphetamines, cannabis, cocaine, opioids, and benzodiazepines are reviewed in the context of the dosing condition and the collection method. Time of last detection is evaluated against several agencies' cutoffs, including the proposed Substance Abuse and Mental Health Services Administration, European Workplace Drug Testing Society and Driving Under the Influence of Drugs, Alcohol and Medicines cutoffs. A significant correlation was frequently observed between matrices (i.e., between OF and plasma or blood concentrations); however, high intra-subject and inter-subject variability precludes prediction of blood concentrations from OF concentrations. This article will assist individuals in understanding the relative merits and limitations of various methods of OF collection, analysis and interpretation.
Collapse
Affiliation(s)
| | - Marilyn A Huestis
- Lambert Center for the Study of Medicinal Cannabis and Hemp, Institute of Emerging Health Professions, Thomas Jefferson University, Philadelphia, PA, USA
| |
Collapse
|
6
|
Abdelshafi NA, Bell J, Rurack K, Schneider RJ. Microfluidic electrochemical immunosensor for the trace analysis of cocaine in water and body fluids. Drug Test Anal 2018; 11:492-500. [PMID: 30286276 DOI: 10.1002/dta.2515] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2018] [Revised: 09/19/2018] [Accepted: 09/26/2018] [Indexed: 12/20/2022]
Abstract
Quick but accurate testing and on-the-spot monitoring of cocaine in oral fluids and urine continues to be an important toxicological issue. In terms of drug testing, a number of devices have been introduced into the market in recent decades, notably for workplace inspection or roadside testing. However, these systems do not always fulfill the requirements in terms of reliability, especially when low cut-off levels are required. With respect to surface water, the presence of anthropogenic small organic molecules such as prescription and over-the-counter pharmaceuticals as well as illicit drugs like cannabinoids, heroin, or cocaine, has become a challenge for scientists to develop new analytical tools for screening and on-site analysis because many of them serve as markers for anthropogenic input and consumer behavior. Here, a modular approach for the detection of cocaine is presented, integrating an electrochemical enzyme-linked immunosorbent assay (ELISA) performed on antibody-grafted magnetic beads in a hybrid microfluidic sensor utilizing flexible tubing, static chip and screen-printed electrode (SPE) elements for incubation, recognition, and cyclic voltammetry measurements. A linear response of the sensor vs. the logarithm of cocaine concentration was obtained with a limit of detection of 0.15 ng/L. Within an overall assay time of 25 minutes, concentrations down to 1 ng/L could be reliably determined in water, oral fluids, and urine, the system possessing a dynamic working range up to 1 mg/L.
Collapse
Affiliation(s)
- Nahla A Abdelshafi
- Bundesanstalt für Materialforschung and -prüfung (BAM), Richard-Willstätter-Straße 11, 12489, Berlin, Germany.,School of Analytical Sciences Adlershof (SALSA), Humboldt-Universität zu Berlin, Unter den Linden 6, 10099, Berlin, Germany
| | - Jérémy Bell
- Bundesanstalt für Materialforschung and -prüfung (BAM), Richard-Willstätter-Straße 11, 12489, Berlin, Germany
| | - Knut Rurack
- Bundesanstalt für Materialforschung and -prüfung (BAM), Richard-Willstätter-Straße 11, 12489, Berlin, Germany
| | - Rudolf J Schneider
- Bundesanstalt für Materialforschung and -prüfung (BAM), Richard-Willstätter-Straße 11, 12489, Berlin, Germany.,Technische Universität Berlin, Straße des 17. Juni 135, 10623, Berlin, Germany
| |
Collapse
|
7
|
Di Fazio V, Wille SMR, Toennes SW, van Wel JHP, Ramaekers JG, Samyn N. Driving under the influence of cocaine: Quantitative determination of basic drugs in oral fluid obtained during roadside controls and a controlled study with cocaine users. Drug Test Anal 2018; 10:1285-1296. [PMID: 29524342 DOI: 10.1002/dta.2379] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2017] [Revised: 02/27/2018] [Accepted: 02/27/2018] [Indexed: 11/06/2022]
Abstract
Using the Belgian Drugs and Driving procedure, 36% of the cocaine-positive oral fluid (OF) screening results were not confirmed in plasma. This study investigates the impact of the choice of screening devices and confirmation matrix on the detection of cocaine use. An ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method quantifying cocaine, benzoylecgonine (BZE), and other basic drugs in OF was developed and validated. This method monitored OF samples obtained either from a roadside (n = 12) or a double-blind controlled study with cocaine users (n = 10) who were given either a capsule containing 300 mg of cocaine-HCl or a placebo. The OF data were compared to plasma concentrations to obtain concentration-time profiles. In addition, the sensitivity and accuracy of the Drugwipe5S® was assessed. A significant difference between the OF volume collected at baseline/placebo (median 0.93 mL [range 0.43-1.92 mL]) or after cocaine-HCL intake (0.79 mL [0.30-1.21 mL]) was observed. The median OF/Plasma at the 3 collection time points were 10.7, 13.8, 6.7 for cocaine and 0.8, 1.7, 0.8 for BZE, respectively. The Drugwipe5S® detected cocaine use until at least 4 hours after intake. When applying the Belgian legal confirmation decision limit of 10 ng/mL in OF, an accuracy of 75%-98% was observed, depending on the study setting. Cocaine concentrations in OF were much higher and were detected longer as compared to plasma, when applying the same decision limit. From a toxicological viewpoint, the longer detection window with the higher sensitivity of Cocaine and BZE is beneficial to detect drivers in the crash/fatigue phase.
Collapse
Affiliation(s)
- Vincent Di Fazio
- National Institute of Criminalistics and Criminology, Laboratory of Toxicology, Brussels, Belgium
| | - Sarah M R Wille
- National Institute of Criminalistics and Criminology, Laboratory of Toxicology, Brussels, Belgium
| | - Stefan W Toennes
- University of Frankfurt, Institute of Legal Medicine, Frankfurt, Germany
| | - Janelle H P van Wel
- Maastricht University, Neuropsychology & Psychopharmacology, Maastricht, Netherlands
| | - Johannes G Ramaekers
- Maastricht University, Neuropsychology & Psychopharmacology, Maastricht, Netherlands
| | - Nele Samyn
- National Institute of Criminalistics and Criminology, Laboratory of Toxicology, Brussels, Belgium
| |
Collapse
|
8
|
Scherer JN, Fiorentin TR, Sousa TRV, Limberger RP, Pechansky F. Oral Fluid Testing for Cocaine: Analytical Evaluation of Two Point-of-Collection Drug Screening Devices. J Anal Toxicol 2017; 41:392-398. [PMID: 28334841 DOI: 10.1093/jat/bkx018] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2016] [Accepted: 02/13/2017] [Indexed: 12/19/2022] Open
Abstract
The use of point-of-collection testing (POCT) devices for drugs of abuse in oral fluid (OF) is an advantageous tool that has been used for different purposes-particularly traffic enforcement. However, even with the widespread report of cocaine consumption, the reliability of POCT devices has been reported in different magnitudes. This study evaluated the reliability of two POCT devices for the detection of cocaine in OF samples of 110 cocaine users: (i) the DDS2™ (cutoff = 30 ng/mL) and (ii) the Multi-Drugs Multi-Line-Twist Screen Test Device™ (MDML) (cutoff = 20 ng/mL). Results of the screening tests were compared with a Liquid Chromatography-Mass Spectrometry (LC-MS) assay. Sensitivity, specificity and accuracy of DDS2™ were 100, 77.77 and 80% when compared with LC-MS with a cutoff of 30 ng/mL, and 88.89, 89.15 and 89.09% with a cutoff of 10 ng/mL. The MDML™ device achieved sensitivity, specificity and accuracy of 100, 65.6 and 70.9% when compared with LC-MS with a cutoff of 20 ng/mL, and 92.6, 71.1 and 76.6% with a cutoff of 10 ng/mL. When compared with a 10 ng/mL cutoff, the DDS2™ achieved reliability parameters higher than 80%. On the other hand, the MDML™ device did not achieve the minimal recommendation of 80% for all parameters at the same time. Taking into consideration the reliability results showed here, the authors believe that the use of these POCT devices seems to be suitable for cocaine detection in forensic tests only if all positive specimens are further confirmed by a validated method.
Collapse
Affiliation(s)
- Juliana Nichterwitz Scherer
- Center for Drug and Alcohol Research, Collaborating Center on Alcohol and Drugs - HCPA/SENAD, Hospital de Clínicas de Porto Alegre, Federal University of Rio Grande do Sul, Rua Professor Álvaro Alvim, 400, 90420-020 Porto Alegre, RS, Brazil
| | - Taís Regina Fiorentin
- Postgraduate Program in Pharmaceutical Sciences, Federal University of Rio Grande do Sul, Av. Ipiranga, 2752, 90610-000 Porto Alegre, RS, Brazil
| | - Tanara Rosangela Vieira Sousa
- Center for Drug and Alcohol Research, Collaborating Center on Alcohol and Drugs - HCPA/SENAD, Hospital de Clínicas de Porto Alegre, Federal University of Rio Grande do Sul, Rua Professor Álvaro Alvim, 400, 90420-020 Porto Alegre, RS, Brazil
| | - Renata Pereira Limberger
- Postgraduate Program in Pharmaceutical Sciences, Federal University of Rio Grande do Sul, Av. Ipiranga, 2752, 90610-000 Porto Alegre, RS, Brazil
| | - Flavio Pechansky
- Center for Drug and Alcohol Research, Collaborating Center on Alcohol and Drugs - HCPA/SENAD, Hospital de Clínicas de Porto Alegre, Federal University of Rio Grande do Sul, Rua Professor Álvaro Alvim, 400, 90420-020 Porto Alegre, RS, Brazil
| |
Collapse
|
9
|
|