1
|
Yan J, Wang J, Liu H, Wang L, Yu K, Deng L, Su J, Chen H. MiR-29b detection in serum using an electrochemical biosensor for the early diagnosis of gestational diabetes. Anal Biochem 2023:115209. [PMID: 37311517 DOI: 10.1016/j.ab.2023.115209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 05/19/2023] [Accepted: 06/05/2023] [Indexed: 06/15/2023]
Abstract
Gestational diabetes mellitus (GDM) is a severe perinatal condition with serious consequences for the growth and development of the mother and baby. MicroRNA-29b (miR-29b) is essential to the pathogenesis of GDM and can be used as a molecular biomarker for diagnosis. Given the limitations of current GDM screening technologies, there is a pressing need for a sensitive detection approach to evaluate serum miR-29b in GDM patients, thus aiding in disease treatment. In this study, an electrochemical biosensor Co7Fe3-CN nanoparticles (NPs) was developed. Using a duplex-specific nuclease (DSN) signal amplification strategy with a linear range of 1-104 pM and a low detection limit of 0.79 pM, the ultra-sensitive detection and quantification of miR-29b were accomplished. The dependability and applicability of the developed biosensor were validated by the standard method of qRT-PCR, and the content of serum miR-29b in GDM patients was shown to be significantly lower than that in the control group (P = 0.03). Specifically, miR-29b concentrations could be detected from 2.0 to 7.5 and 2.4-7.3 pM using qRT-PCR and the biosensor, respectively. These similar results indicated that a biosensor based on miR-29b detection has the potential to be used in the point-of-care testing of GDM patients in clinical practice.
Collapse
Affiliation(s)
- Jianhua Yan
- Medical College, Guangxi University, Guangxi Nanning, 530004, China
| | - Jiayu Wang
- Medical College, Guangxi University, Guangxi Nanning, 530004, China
| | - Hongjie Liu
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning, 530004, China
| | - Liwei Wang
- School of Marine Sciences, Coral Reef Research Center of China, Guangxi Laboratory on the Study of Coral Reefs in the South China Sea, Guangxi University, Nanning, 530004, China; State Key Laboratory of Featured Metal Materials and Life-cycle Safety for Composite Structures, Guangxi University, Nanning, 530004, China; Southern Marine Science and Engineering Guangdong Laboratory (Zhuhai), Zhuhai, 519080, China.
| | - Kefu Yu
- School of Marine Sciences, Coral Reef Research Center of China, Guangxi Laboratory on the Study of Coral Reefs in the South China Sea, Guangxi University, Nanning, 530004, China; Southern Marine Science and Engineering Guangdong Laboratory (Zhuhai), Zhuhai, 519080, China
| | - Li Deng
- Department of Obstetrics, The Second Affiliated Hospital of Guangxi Medical University, Nanning, 530003, China
| | - Junyou Su
- Department of Obstetrics, The Second Affiliated Hospital of Guangxi Medical University, Nanning, 530003, China
| | - Hongfei Chen
- Department of Obstetrics, The Second Affiliated Hospital of Guangxi Medical University, Nanning, 530003, China
| |
Collapse
|
2
|
Trotter M, Borst N, Thewes R, von Stetten F. Review: Electrochemical DNA sensing – Principles, commercial systems, and applications. Biosens Bioelectron 2020; 154:112069. [DOI: 10.1016/j.bios.2020.112069] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Revised: 01/28/2020] [Accepted: 02/01/2020] [Indexed: 02/06/2023]
|
3
|
Park JH, Dehaini D, Zhou J, Holay M, Fang RH, Zhang L. Biomimetic nanoparticle technology for cardiovascular disease detection and treatment. NANOSCALE HORIZONS 2020; 5:25-42. [PMID: 32133150 PMCID: PMC7055493 DOI: 10.1039/c9nh00291j] [Citation(s) in RCA: 60] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Cardiovascular disease (CVD), which encompasses a number of conditions that can affect the heart and blood vessels, presents a major challenge for modern-day healthcare. Nearly one in three people has some form of CVD, with many suffering from multiple or intertwined conditions that can ultimately lead to traumatic events such as a heart attack or stroke. While the knowledge obtained in the past century regarding the cardiovascular system has paved the way for the development of life-prolonging drugs and treatment modalities, CVD remains one of the leading causes of death in developed countries. More recently, researchers have explored the application of nanotechnology to improve upon current clinical paradigms for the management of CVD. Nanoscale delivery systems have many advantages, including the ability to target diseased sites, improve drug bioavailability, and carry various functional payloads. In this review, we cover the different ways in which nanoparticle technology can be applied towards CVD diagnostics and treatments. The development of novel biomimetic platforms with enhanced functionalities is discussed in detail.
Collapse
Affiliation(s)
| | | | - Jiarong Zhou
- Department of NanoEngineering, Chemical Engineering Program, and Moores Cancer Center, University of California San Diego, La Jolla, CA 92093, USA
| | - Maya Holay
- Department of NanoEngineering, Chemical Engineering Program, and Moores Cancer Center, University of California San Diego, La Jolla, CA 92093, USA
| | - Ronnie H. Fang
- Department of NanoEngineering, Chemical Engineering Program, and Moores Cancer Center, University of California San Diego, La Jolla, CA 92093, USA
| | - Liangfang Zhang
- Department of NanoEngineering, Chemical Engineering Program, and Moores Cancer Center, University of California San Diego, La Jolla, CA 92093, USA
| |
Collapse
|
4
|
Varodi C, Pogacean F, Coros M, Rosu MC, Stefan-van Staden RI, Gal E, Tudoran LB, Pruneanu S, Mirel S. Detection of 8-Hydroxy-2'-Deoxyguanosine Biomarker with a Screen-Printed Electrode Modified with Graphene. SENSORS 2019; 19:s19194297. [PMID: 31590208 PMCID: PMC6806156 DOI: 10.3390/s19194297] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Revised: 09/25/2019] [Accepted: 09/29/2019] [Indexed: 12/13/2022]
Abstract
In this work we present the preparation of graphene material by exfoliation of graphite rods via pulses of current in electrolyte, containing a mixture of boric acid (0.05 M) and sodium chloride (0.05 M). The material was morphologically and structurally characterized by SEM/TEM/HR-TEM, XRD and FTIR techniques. TEM investigation of graphene flakes deposited onto carbon-coated grids allowed the visualization of thin and transparent regions, attributed to few-layer graphene (FLG), as well as thick and dark regions attributed to multi-layer graphene (MLG). The mixed composition of the material was additionally confirmed by XRD, which further indicated that the amount of FLG within the sample was around 83%, while MLG was around 17%. The performance of a screen-printed electrode (SPE) modified with graphene (SPE-Gr) was tested for 8-hydroxy-2′-deoxyguanosine detection. The graphene-modified electrode had a higher sensitivity in comparison with that of SPE, both in standard laboratory solutions (phosphate buffered saline—PBS) and in human saliva.
Collapse
Affiliation(s)
- Codruta Varodi
- National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103 Donat Street, Cluj-Napoca 400293, Romania
| | - Florina Pogacean
- National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103 Donat Street, Cluj-Napoca 400293, Romania
| | - Maria Coros
- National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103 Donat Street, Cluj-Napoca 400293, Romania
| | - Marcela-Corina Rosu
- National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103 Donat Street, Cluj-Napoca 400293, Romania
| | - Raluca-Ioana Stefan-van Staden
- Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Street, Bucharest-6 060021, Romania
- Faculty of Applied Chemistry and Material Science, Politehnica University of Bucharest, Bucharest RO-060042, Romania
| | - Emese Gal
- Department of Chemistry and Chemical Engineering, Hungarian Line of Study, Babes-Bolyai University, 11 Arany János St., Cluj-Napoca 400028, Romania
| | - Lucian-Barbu Tudoran
- National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103 Donat Street, Cluj-Napoca 400293, Romania
- Faculty of Biology and Geology, Electron Microscopy Lab, Babes-Bolyai University, 5-7 Clinicilor St., Cluj-Napoca RO-400015, Romania
| | - Stela Pruneanu
- National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103 Donat Street, Cluj-Napoca 400293, Romania.
| | - Simona Mirel
- Faculty of Pharmacy, "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca 400349, Romania
| |
Collapse
|
5
|
Márquez A, Aymerich J, Dei M, Rodríguez-Rodríguez R, Vázquez-Carrera M, Pizarro-Delgado J, Giménez-Gómez P, Merlos Á, Terés L, Serra-Graells F, Jiménez-Jorquera C, Domínguez C, Muñoz-Berbel X. Reconfigurable multiplexed point of Care System for monitoring type 1 diabetes patients. Biosens Bioelectron 2019; 136:38-46. [DOI: 10.1016/j.bios.2019.04.015] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Revised: 04/02/2019] [Accepted: 04/07/2019] [Indexed: 01/15/2023]
|
6
|
Dietvorst J, Goyvaerts J, Ackermann TN, Alvarez E, Muñoz-Berbel X, Llobera A. Microfluidic-controlled optical router for lab on a chip. LAB ON A CHIP 2019; 19:2081-2088. [PMID: 31114831 DOI: 10.1039/c9lc00143c] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
In multiplexed analysis, lab on a chip (LoC) devices are advantageous due to the low sample and reagent volumes required. Although optical detection is preferred for providing high sensitivity in a contactless configuration, multiplexed optical LoCs are limited by the technological complexity for integrating multiple light sources and detectors in a single device. To address this issue, we present a microfluidic-controlled optical router that enables measurement in four individual optical channels using a single light source and detector, and without movable parts. The optofluidic device is entirely fabricated in polydimethylsiloxane (PDMS) by soft-lithography, compatible with standard microfabrication technologies, enabling monolithic integration in LoCs. In the device, in-coupled light from an optical fiber is collimated by a polymeric micro-lens and guided through a set of four sequentially connected micro-chambers. When a micro-chamber is filled with water, light is transmitted to the next one. If it is empty of liquid, however, total internal reflection (TIR) occurs at the PDMS-air interface, re-directing the light to the output optical fiber. The router presents high performance, with low cross-talk (<2%) and high switching frequencies (up to 0.343 ± 0.006 Hz), and provides a stable signal for up to 91% of the switching time. With this miniaturized, low-cost, simple and robust design, we expect the current technology to be integrated in the new generation of multiplexed photonic LoCs for biomarker analysis, even at the point of care.
Collapse
Affiliation(s)
- Jiri Dietvorst
- Institut de Microelectrònica de Barcelona (IMB-CNM, CSIC), Campus UAB, 08193 Bellaterra, Barcelona, Spain.
| | | | | | | | | | | |
Collapse
|
7
|
Controlling parameters and characteristics of electrochemical biosensors for enhanced detection of 8-hydroxy-2'-deoxyguanosine. Sci Rep 2019; 9:7411. [PMID: 31092871 PMCID: PMC6520373 DOI: 10.1038/s41598-019-43680-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2018] [Accepted: 04/26/2019] [Indexed: 11/18/2022] Open
Abstract
This work discusses the parameters and characteristics required on the development of a scalable and reliable electrochemical sensor board for detecting 8-hydroxy-2′-deoxyguanosine (8-OHdG), an oxidative stress biomarker for diabetic nephropathy, cancer and Parkinson’s disease. We used Printed Circuit Board (PCB) technology to make a precise, low-cost bare sensor board. ZnO nanorods (NRs) and ZnO NRs: reduced graphene oxide (RGO) composites were used as a pathway for antibody immobilization on the working electrode (WE). The parameters and characteristics of the WE were controlled for enhancing the quality of the electrochemical sensor board. Thickness of the gold and the presence of ZnO NRs or their composite on the WE have influence on charge transference process and reproducibility of the sensor board. The amount of the antibody, and its incubation period are crucial to avoid saturation of the sites during immobilization step and reduce the cost of the sensor. Our ZnO NRs-based electrochemical sensor board showed high sensitivity and selectivity to 8-OHdG with detection capacity in the range of 0.001–5.00 ng.mL−1. The successful application of our immunosensor to detect 8-OHdG in urine was evidenced.
Collapse
|
8
|
Bruch R, Chatelle C, Kling A, Rebmann B, Wirth S, Schumann S, Weber W, Dincer C, Urban G. Clinical on-site monitoring of ß-lactam antibiotics for a personalized antibiotherapy. Sci Rep 2017; 7:3127. [PMID: 28600499 PMCID: PMC5466632 DOI: 10.1038/s41598-017-03338-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Accepted: 04/26/2017] [Indexed: 01/07/2023] Open
Abstract
An appropriate antibiotherapy is crucial for the safety and recovery of patients. Depending on the clinical conditions of patients, the required dose to effectively eradicate an infection may vary. An inadequate dosing not only reduces the efficacy of the antibiotic, but also promotes the emergence of antimicrobial resistances. Therefore, a personalized therapy is of great interest for improved patients' outcome and will reduce in long-term the prevalence of multidrug-resistances. In this context, on-site monitoring of the antibiotic blood concentration is fundamental to facilitate an individual adjustment of the antibiotherapy. Herein, we present a bioinspired approach for the bedside monitoring of free accessible ß-lactam antibiotics, including penicillins (piperacillin) and cephalosporins (cefuroxime and cefazolin) in untreated plasma samples. The introduced system combines a disposable microfluidic chip with a naturally occurring penicillin-binding protein, resulting in a high-performance platform, capable of gauging very low antibiotic concentrations (less than 6 ng ml-1) from only 1 µl of serum. The system's applicability to a personalized antibiotherapy was successfully demonstrated by monitoring the pharmacokinetics of patients, treated with ß-lactam antibiotics, undergoing surgery.
Collapse
Affiliation(s)
- R Bruch
- Department of Microsystems Engineering, University of Freiburg, 79110, Freiburg, Germany
| | - C Chatelle
- Faculty of Biology, University of Freiburg, 79104, Freiburg, Germany.,BIOSS Centre for Biological Signalling Studies, University of Freiburg, 79104, Freiburg, Germany
| | - A Kling
- Department of Biosystems Science and Engineering, ETH Zurich, 4058, Basel, Switzerland
| | - B Rebmann
- Faculty of Biology, University of Freiburg, 79104, Freiburg, Germany.,BIOSS Centre for Biological Signalling Studies, University of Freiburg, 79104, Freiburg, Germany
| | - S Wirth
- Department of Anaesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, 79106, Freiburg, Germany
| | - S Schumann
- Department of Anaesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, 79106, Freiburg, Germany
| | - W Weber
- Faculty of Biology, University of Freiburg, 79104, Freiburg, Germany.,BIOSS Centre for Biological Signalling Studies, University of Freiburg, 79104, Freiburg, Germany
| | - C Dincer
- Department of Microsystems Engineering, University of Freiburg, 79110, Freiburg, Germany. .,Freiburg Materials Research Center, University of Freiburg, 79104, Freiburg, Germany.
| | - G Urban
- Department of Microsystems Engineering, University of Freiburg, 79110, Freiburg, Germany.,Freiburg Materials Research Center, University of Freiburg, 79104, Freiburg, Germany
| |
Collapse
|
9
|
Dincer C, Bruch R, Kling A, Dittrich PS, Urban GA. Multiplexed Point-of-Care Testing - xPOCT. Trends Biotechnol 2017; 35:728-742. [PMID: 28456344 PMCID: PMC5538621 DOI: 10.1016/j.tibtech.2017.03.013] [Citation(s) in RCA: 309] [Impact Index Per Article: 44.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Revised: 03/24/2017] [Accepted: 03/28/2017] [Indexed: 12/13/2022]
Abstract
Multiplexed point-of-care testing (xPOCT), which is simultaneous on-site detection of different analytes from a single specimen, has recently gained increasing importance for clinical diagnostics, with emerging applications in resource-limited settings (such as in the developing world, in doctors’ offices, or directly at home). Nevertheless, only single-analyte approaches are typically considered as the major paradigm in many reviews of point-of-care testing. Here, we comprehensively review the present diagnostic systems and techniques for xPOCT applications. Different multiplexing technologies (e.g., bead- or array-based systems) are considered along with their detection methods (e.g., electrochemical or optical). We also address the unmet needs and challenges of xPOCT. Finally, we critically summarize the in-field applicability and the future perspectives of the presented approaches. Simultaneous on-site measurement of different substances from a single sample, called multiplexed point-of-care testing, has recently become more and more important for in vitro diagnostics. The major aim for the development of xPOCT systems is the smart combination of a high-performing device with a low system complexity. Thus, the on-site tests are realized in a short time by non-experts and ensure comparable results with clinical and central laboratory findings. A multiplexing capability of up to 10 analytes has been sufficient for many recent xPOCT applications. The future of xPOCT devices will be driven by novel biotechnologies (e.g., aptamers) or targets (e.g., circulating RNAs or tumor cells, exosomes, and miRNAs), as well as applications like personalized medicine, homecare monitoring, and wearables.
Collapse
Affiliation(s)
- Can Dincer
- University of Freiburg, Department of Microsystems Engineering (IMTEK), Laboratory for Sensors, Georges-Koehler-Allee 103, 79110 Freiburg, Germany; University of Freiburg, Freiburg Materials Research Center (FMF), Stefan-Meier-Straße 21, 79104 Freiburg, Germany.
| | - Richard Bruch
- University of Freiburg, Department of Microsystems Engineering (IMTEK), Laboratory for Sensors, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
| | - André Kling
- ETH Zurich, Department of Biosystems Science and Engineering, Bioanalytics Group, Mattenstrasse 26, 4058 Basel, Switzerland
| | - Petra S Dittrich
- ETH Zurich, Department of Biosystems Science and Engineering, Bioanalytics Group, Mattenstrasse 26, 4058 Basel, Switzerland
| | - Gerald A Urban
- University of Freiburg, Department of Microsystems Engineering (IMTEK), Laboratory for Sensors, Georges-Koehler-Allee 103, 79110 Freiburg, Germany; University of Freiburg, Freiburg Materials Research Center (FMF), Stefan-Meier-Straße 21, 79104 Freiburg, Germany
| |
Collapse
|
10
|
Kling A, Chatelle C, Armbrecht L, Qelibari E, Kieninger J, Dincer C, Weber W, Urban G. Multianalyte Antibiotic Detection on an Electrochemical Microfluidic Platform. Anal Chem 2016; 88:10036-10043. [DOI: 10.1021/acs.analchem.6b02294] [Citation(s) in RCA: 60] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- André Kling
- University of Freiburg, Department of Microsystems
Engineering, Georges-Koehler-Allee
103, DE-79110 Freiburg, Germany
| | - Claire Chatelle
- University of Freiburg, Faculty of Biology and Centre
for Biological Signalling Studies, Schänzlestraße 18, DE-79104 Freiburg, Germany
| | - Lucas Armbrecht
- University of Freiburg, Department of Microsystems
Engineering, Georges-Koehler-Allee
103, DE-79110 Freiburg, Germany
| | - Edvina Qelibari
- University of Freiburg, Department of Microsystems
Engineering, Georges-Koehler-Allee
103, DE-79110 Freiburg, Germany
| | - Jochen Kieninger
- University of Freiburg, Department of Microsystems
Engineering, Georges-Koehler-Allee
103, DE-79110 Freiburg, Germany
| | - Can Dincer
- University of Freiburg, Department of Microsystems
Engineering, Georges-Koehler-Allee
103, DE-79110 Freiburg, Germany
- University of Freiburg, Freiburg Materials Research
Center, Stefan-Meier-Straße
21, DE-79104 Freiburg, Germany
| | - Wilfried Weber
- University of Freiburg, Faculty of Biology and Centre
for Biological Signalling Studies, Schänzlestraße 18, DE-79104 Freiburg, Germany
| | - Gerald Urban
- University of Freiburg, Department of Microsystems
Engineering, Georges-Koehler-Allee
103, DE-79110 Freiburg, Germany
- University of Freiburg, Freiburg Materials Research
Center, Stefan-Meier-Straße
21, DE-79104 Freiburg, Germany
| |
Collapse
|
11
|
Ortiz M, Joda H, Höth J, Beni V, Katakis I, Klemm R, Lind K, O'Sullivan CK, Fragoso A. Bleed-to-read disposable microsystems for the genetic and serological analysis of celiac disease markers with amperometric detection. Electrophoresis 2015; 36:1920-6. [DOI: 10.1002/elps.201500140] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2015] [Revised: 05/03/2015] [Accepted: 05/04/2015] [Indexed: 11/08/2022]
Affiliation(s)
- Mayreli Ortiz
- Nanobiotechnology and Bioanalysis Group; Departament d'Enginyeria Química; Universitat Rovira i Virgili; Tarragona Spain
| | - Hamdi Joda
- Nanobiotechnology and Bioanalysis Group; Departament d'Enginyeria Química; Universitat Rovira i Virgili; Tarragona Spain
| | | | - Valerio Beni
- Nanobiotechnology and Bioanalysis Group; Departament d'Enginyeria Química; Universitat Rovira i Virgili; Tarragona Spain
| | - Ioanis Katakis
- Nanobiotechnology and Bioanalysis Group; Departament d'Enginyeria Química; Universitat Rovira i Virgili; Tarragona Spain
| | | | | | - Ciara K. O'Sullivan
- Nanobiotechnology and Bioanalysis Group; Departament d'Enginyeria Química; Universitat Rovira i Virgili; Tarragona Spain
- Institució Catalana de Recerca i Estudis Avançats; Passeig Lluis Companys; Barcelona Spain
| | - Alex Fragoso
- Nanobiotechnology and Bioanalysis Group; Departament d'Enginyeria Química; Universitat Rovira i Virgili; Tarragona Spain
| |
Collapse
|
12
|
Díaz-González M, Salvador JP, Bonilla D, Marco MP, Fernández-Sánchez C, Baldi A. A microfluidic device for the automated electrical readout of low-density glass-slide microarrays. Biosens Bioelectron 2015. [PMID: 26210466 DOI: 10.1016/j.bios.2015.07.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Microarrays are a powerful platform for rapid and multiplexed analysis in a wide range of research fields. Electrical readout systems have emerged as an alternative to conventional optical methods for microarray analysis thanks to its potential advantages like low-cost, low-power and easy miniaturization of the required instrumentation. In this work an automated electrical readout system for low-cost glass-slide microarrays is described. The system enables the simultaneous conductimetric detection of up to 36 biorecognition events by incorporating an array of interdigitated electrode transducers. A polydimethylsiloxane microfluidic structure has been designed that creates microwells over the transducers and incorporates the microfluidic channels required for filling and draining them with readout and cleaning solutions, thus making the readout process fully automated. Since the capture biomolecules are not immobilized on the transducer surface this readout system is reusable, in contrast to previously reported electrochemical microarrays. A low-density microarray based on a competitive enzymatic immunoassay for atrazine detection was used to test the performance of the readout system. The electrical assay shows a detection limit of 0.22±0.03 μg L(-1) similar to that obtained with fluorescent detection and allows the direct determination of the pesticide in polluted water samples. These results proved that an electrical readout system such as the one presented in this work is a reliable and cost-effective alternative to fluorescence scanners for the analysis of low-density microarrays.
Collapse
Affiliation(s)
- María Díaz-González
- Instituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus UAB, 08193 Bellaterra, Barcelona, Spain.
| | - J Pablo Salvador
- Nanobiotechnology for Diagnostics (Nb4D) Group, IQAC-CSIC, Jordi Girona 18-26, 08034 Barcelona, Spain
| | - Diana Bonilla
- Instituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus UAB, 08193 Bellaterra, Barcelona, Spain
| | - M Pilar Marco
- Nanobiotechnology for Diagnostics (Nb4D) Group, IQAC-CSIC, Jordi Girona 18-26, 08034 Barcelona, Spain
| | - César Fernández-Sánchez
- Instituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus UAB, 08193 Bellaterra, Barcelona, Spain
| | - Antoni Baldi
- Instituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus UAB, 08193 Bellaterra, Barcelona, Spain
| |
Collapse
|
13
|
Tertiş M, Hosu O, Fritea L, Farcau C, Cernat A, Săndulescu R, Cristea C. A Novel Label-Free Immunosensor Based on Activated Graphene Oxide for Acetaminophen Detection. ELECTROANAL 2015. [DOI: 10.1002/elan.201400583] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
14
|
Applications of electrochemical immunosensors for early clinical diagnostics. Talanta 2015; 132:162-74. [DOI: 10.1016/j.talanta.2014.08.063] [Citation(s) in RCA: 133] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2014] [Revised: 08/18/2014] [Accepted: 08/27/2014] [Indexed: 12/13/2022]
|
15
|
Luo X, Xu Q, James T, Davis JJ. Redox and Label-Free Array Detection of Protein Markers in Human Serum. Anal Chem 2014; 86:5553-8. [DOI: 10.1021/ac5010037] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Xiliang Luo
- Key
Laboratory of Biochemical Analysis, Ministry of Education, College
of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, China
- Department
of Chemistry, University of Oxford, Oxford OX1 3QZ, U.K
| | - Qiao Xu
- Department
of Chemistry, University of Oxford, Oxford OX1 3QZ, U.K
| | - Tim James
- Department
of Clinical Biochemistry, Oxford University Hospitals NHS Trust, Oxford OX3 9DU, U.K
| | - Jason J. Davis
- Department
of Chemistry, University of Oxford, Oxford OX1 3QZ, U.K
| |
Collapse
|