1
|
Posch TN, Pütz M, Martin N, Huhn C. Electromigrative separation techniques in forensic science: combining selectivity, sensitivity, and robustness. Anal Bioanal Chem 2014; 407:23-58. [PMID: 25381613 DOI: 10.1007/s00216-014-8271-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2014] [Revised: 10/12/2014] [Accepted: 10/14/2014] [Indexed: 01/27/2023]
Abstract
In this review we introduce the advantages and limitations of electromigrative separation techniques in forensic toxicology. We thus present a summary of illustrative studies and our own experience in the field together with established methods from the German Federal Criminal Police Office rather than a complete survey. We focus on the analytical aspects of analytes' physicochemical characteristics (e.g. polarity, stereoisomers) and analytical challenges including matrix tolerance, separation from compounds present in large excess, sample volumes, and orthogonality. For these aspects we want to reveal the specific advantages over more traditional methods. Both detailed studies and profiling and screening studies are taken into account. Care was taken to nearly exclusively document well-validated methods outstanding for the analytical challenge discussed. Special attention was paid to aspects exclusive to electromigrative separation techniques, including the use of the mobility axis, the potential for on-site instrumentation, and the capillary format for immunoassays. The review concludes with an introductory guide to method development for different separation modes, presenting typical buffer systems as starting points for different analyte classes. The objective of this review is to provide an orientation for users in separation science considering using capillary electrophoresis in their laboratory in the future.
Collapse
Affiliation(s)
- Tjorben Nils Posch
- Forschungszentrum Jülich GmbH, Central Institute for Engineering, Electronics and Analytics, Analytics ZEA-3, 52425, Jülich, Germany
| | | | | | | |
Collapse
|
2
|
Kiessig S, Stettler A, Fuhrimann S, Schwarz MA. Affinity Capillary Electrophoresis as a Tool to Characterize Intermolecular Interactions. Supramol Chem 2012. [DOI: 10.1002/9780470661345.smc035] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
3
|
Cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography for the analysis of methadone and its metabolites in serum of heroin addicts. J Chromatogr A 2011; 1218:6832-7. [DOI: 10.1016/j.chroma.2011.07.086] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2011] [Revised: 07/25/2011] [Accepted: 07/26/2011] [Indexed: 11/18/2022]
|
4
|
Szökő É, Tábi T. Analysis of biological samples by capillary electrophoresis with laser induced fluorescence detection. J Pharm Biomed Anal 2010; 53:1180-92. [DOI: 10.1016/j.jpba.2010.07.045] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2010] [Revised: 07/23/2010] [Accepted: 07/27/2010] [Indexed: 12/26/2022]
|
5
|
Wang Q, Luo G, Wang Y, Yeung WS. Capillary Electrophoresis Based Immunoassay for Monoclonal Antibody with Diode Laser Induced Fluorescence Detection. ANAL LETT 2008. [DOI: 10.1080/00032710008543076] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
6
|
Kelly T, Doble P, Dawson M. A fast CE method for the achiral separation of methadone and its major metabolites, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine and 2-ethyl-5-methyl-3,3-diphenyl-1-pyrroline. Electrophoresis 2007; 28:3566-9. [PMID: 17847129 DOI: 10.1002/elps.200700090] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The utilization of dynamic doubly coated capillaries for a fast separation of methadone and its two major metabolites, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) and 2-ethyl-5-methyl-3,3-diphenyl-1-pyrroline (EMDP) was investigated. The coated capillaries were prepared using a polycation of poly(diallyldimethylammonium chloride) and a polyanion of dextran sulfate. A fast achiral separation was developed using the coated capillaries with a BGE of 100 mM phosphate buffer at pH 2.6. Complete achiral separation of methadone, EDDP and EMDP was achieved, with migration times of approximately 4 min. The method offers considerable advantages with respect to BGE simplicity and analysis time compared to previously published CE methods for methadone and its related analytes.
Collapse
Affiliation(s)
- Tamsin Kelly
- Centre for Forensic Science, Faculty of Science, University of Technology, Sydney, NSW, Australia
| | | | | |
Collapse
|
7
|
Sniehotta M, Schiffer E, Zürbig P, Novak J, Mischak H. CE – a multifunctional application for clinical diagnosis. Electrophoresis 2007; 28:1407-17. [PMID: 17427258 DOI: 10.1002/elps.200600581] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
CE has been used widely as an analytical tool with high separation power taking advantage of size, charge-to-size ratio, or isoelectric point of various analytes. In combination with detection methods, such as UV absorption, electrochemical detection, fluorescence, or mass spectrometry (MS), it allows the separation and detection of inorganic and organic ions, as well as complex compounds, such as polypeptides, nucleic acids, including PCR amplicons from viruses or bacteria. Recent interest in identification of biomarkers of diseases using body fluids leads to development of CE-MS techniques. These applications allowed identification of new potential biomarkers for clinical diagnosis and monitoring of therapeutic interventions. In this report, we present a technical overview of various CE techniques and discuss their applications in clinical medicine.
Collapse
Affiliation(s)
- Maike Sniehotta
- Mosaiques Diagnostics and Therapeutics AG, Hannover, Germany
| | | | | | | | | |
Collapse
|
8
|
Mercolini L, Mandrioli R, Conti M, Leonardi C, Gerra G, Raggi MA. Simultaneous determination of methadone, buprenorphine and norbuprenorphine in biological fluids for therapeutic drug monitoring purposes. J Chromatogr B Analyt Technol Biomed Life Sci 2007; 847:95-102. [PMID: 17046338 DOI: 10.1016/j.jchromb.2006.09.035] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2006] [Revised: 09/06/2006] [Accepted: 09/20/2006] [Indexed: 10/23/2022]
Abstract
Methadone and buprenorphine are two of the drugs most frequently used for abstinence from illicit opioids and in the treatment of pain. A sensitive and selective high-performance liquid chromatographic method with diode array detection for the simultaneous determination of methadone, buprenorphine and norbuprenorphine has been developed. Separation of the three analytes was obtained by using a reversed-phase column (C8, 250mmx4.6mm i.d., 5microm) and a mobile phase composed of 40% phosphate buffer containing triethylamine, 50% methanol and 10% acetonitrile (final apparent pH 6.0). Loxapine was used as the internal standard. An accurate pre-treatment procedure of biological samples was developed, using solid-phase extraction with C8 cartridges (100mg, 1mL) and needing small amounts of plasma or urine (300microL). The calibration curves were linear over a working range of 10.0-1500.0ng/mL for methadone and of 5.0-500.0ng/mL for buprenorphine and norbuprenorphine in both matrices. The limit of quantitation (LOQ) and the limit of detection (LOD) were 1.0 and 0.4ng/mL for methadone and 0.5 and 0.2ng/mL for both buprenorphine and norbuprenorphine, respectively. The method was successfully applied to the analysis of plasma and urine samples from patients undergoing treatment with these drugs. Precision and accuracy results were satisfactory and no interference from endogenous or exogenous compounds was found. The method is suitable for the simultaneous determination of methadone and buprenorphine in human plasma and urine for therapeutic drug monitoring purposes.
Collapse
Affiliation(s)
- Laura Mercolini
- Faculty of Pharmacy, Department of Pharmaceutical Sciences, Alma Mater Studiorum-University of Bologna, Via Belmeloro 6, I-40126 Bologna, Italy
| | | | | | | | | | | |
Collapse
|
9
|
Abstract
This paper reviews immunoaffinity CE procedures developed since 1998 for drug, hormone, and disease marker analyses of body fluids and tissues. Immunoaffinity CE and related techniques are described. Examples of clinical applications are included.
Collapse
Affiliation(s)
- Lotta K Amundsen
- Technical Research Centre of Finland (VTT), P.O. Box 1000, FIN-02044 VTT, Finland
| | | |
Collapse
|
10
|
|
11
|
Yeung WSB, Luo GA, Wang QG, Ou JP. Capillary electrophoresis-based immunoassay. J Chromatogr B Analyt Technol Biomed Life Sci 2004; 797:217-28. [PMID: 14630151 DOI: 10.1016/s1570-0232(03)00489-6] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Capillary electrophoresis-based immunoassay (CEIA) is a developing analytical technique with a number of advantages over conventional immunoassay, such as reduced sample consumption, simpler procedure, easy simultaneous determination of multiple analytes, and short analysis time. However, there are still a number of technical issues that researchers on CEIA have to solve before the assay can be more widely used. These issues include method to improve the concentration sensitivity of the assay, requirement for robust separation strategy for different analytes, and method to increase the throughput of the assay. The approaches to solve these issues are reviewed. Several studies have been devoted to develop general separation strategies for CEIA, and to enhance the sensitivity of detection. The recent development of microchip-based CEIA is encouraging and is likely to address more drawbacks of CEIA, particularly on the throughput issue.
Collapse
Affiliation(s)
- W S B Yeung
- Department of Obstetrics and Gynaecology, The University of Hong Kong, Queen Mary Hospital, Pokfulam Road, Hong Kong, PR China.
| | | | | | | |
Collapse
|
12
|
Immunoassays using capillary electrophoresis laser induced fluorescence detection for DNA adducts. Anal Chim Acta 2003. [DOI: 10.1016/s0003-2670(03)00631-7] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
13
|
Caslavska J, Thormann W. Rapid analysis of furosemide in human urine by capillary electrophoresis with laser-induced fluorescence and electrospray ionization-ion trap mass spectrometric detection. J Chromatogr B Analyt Technol Biomed Life Sci 2002; 770:207-16. [PMID: 12013228 DOI: 10.1016/s0378-4347(01)00560-6] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Furosemide, a drug that promotes urine excretion, is used in the pharmacotherapy of various diseases and is considered as a doping agent in sports. Using alkaline electrolytes, analysis of furosemide by dodecyl sulfate based micellar electrokinetic capillary chromatography (MECC) and capillary zone electrophoresis (CZE) with laser-induced fluorescence detection (LIF, analyte excitation with the 325 nm line of a HeCd laser) is described. Data produced by injection of plain or diluted patient urines are confirmed with those obtained via analysis of urinary solid-phase extracts. CZE-LIF and MECC-LIF are thereby shown to permit unambiguous recognition of furosemide in urines collected after ingestion of therapeutic doses of this drug. This is in contrast to solute detection via UV absorbance for which the extraction of furosemide is required. MECC based electropherograms are somewhat more complex compared to those obtained by CZE-LIF, this suggesting that the latter approach is more suitable for rapid screening of urines with direct sample injection and LIF detection. Alternatively, capillary electrophoresis with negative electrospray ionization-ion-trap tandem mass spectrometry (CE-MS2) is shown to permit the direct confirmation of furosemide in human urine. This approach is based upon the monitoring of the m/z 329.3-->4m/z 285.2 precursor-product ion transition. CZE-LIF and CE-MS2 with injection of plain or diluted urine represent simple, rapid and attractive urinary screening and confirmation assays for furosemide in patient urines.
Collapse
Affiliation(s)
- J Caslavska
- Department of Clinical Pharmacology, University of Bern, Switzerland
| | | |
Collapse
|
14
|
Ortelli D, Rudaz S, Souverain S, Veuthey J. Restricted access materials for fast analysis of methadone in serum with liquid chromatography‐mass spectrometry. J Sep Sci 2002. [DOI: 10.1002/1615-9314(20020301)25:4<222::aid-jssc222>3.0.co;2-#] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Didier Ortelli
- Laboratory of Pharmaceutical Analytical Chemistry, University of Geneva, Bd. d'Yvoy 20, 1211 Geneva 4, Switzerland; Fax: +41 22 7815193
| | - Serge Rudaz
- Laboratory of Pharmaceutical Analytical Chemistry, University of Geneva, Bd. d'Yvoy 20, 1211 Geneva 4, Switzerland; Fax: +41 22 7815193
| | - Sandrine Souverain
- Laboratory of Pharmaceutical Analytical Chemistry, University of Geneva, Bd. d'Yvoy 20, 1211 Geneva 4, Switzerland; Fax: +41 22 7815193
| | | |
Collapse
|
15
|
Heegaard NHH, Kennedy RT. Antigen-antibody interactions in capillary electrophoresis. J Chromatogr B Analyt Technol Biomed Life Sci 2002; 768:93-103. [PMID: 11939562 DOI: 10.1016/s0378-4347(01)00489-3] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Immunoreactions in combination with separations by capillary electrophoresis (CE) are increasingly being used to quantitate specific analytes in biological fluids. Both competitive and non-competitive approaches have been used for the purpose and, in selected cases, now compare favorably with conventional quantitative immunoassays with respect to concentration limits of detection. CE is also a useful method to evaluate antigen-antibody binding on-line and offers unique possibilities for binding constant estimates, also for weakly binding antibodies and antibody fragments. In this review we cover recent developments in the use of antigen-antibody interactions in conjunction with CE and conclude that continued development of miniaturization, on-line preconcentration and more sensitive detection schemes will contribute to the further dissemination of CE-based immunoassays building on already established affinity CE approaches.
Collapse
Affiliation(s)
- Niels H H Heegaard
- Department of Autoimmunology, Statens Serum Institute, Copenhagen, Denmark.
| | | |
Collapse
|
16
|
Wey AB, Thormann W. Head-column field-amplified sample stacking in presence of siphoning. Application to capillary electrophoresis-electrospray ionization mass spectrometry of opioids in urine. J Chromatogr A 2001; 924:507-18. [PMID: 11521903 DOI: 10.1016/s0021-9673(01)00986-4] [Citation(s) in RCA: 45] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Capillary electrophoresis (CE) with head-column field-amplified sample stacking (FASS) in presence of a water plug inserted at the capillary tip is a robust approach providing a more than 1000-fold sensitivity enhancement when applied to low-conductivity samples that are analyzed in an integrated instrument. Employing modular systems comprising a small hydrodynamic buffer flow (siphoning) towards the capillary end and featuring UV absorption or electrospray ionization mass spectrometric (MS) detection, insertion of a water plug is demonstrated to deteriorate the performance of head-column FASS or making it unfunctional. Electroinjection in the absence of the water plug can be employed instead and is shown to provide a ng/ml sensitivity when applied to low conductivity samples. With some suction of sample into the capillary during electroinjection, contamination of the sample vial with buffer is thereby largely avoided. Electroinjection applied to the CE-ion trap MS-MS and MS-MS-MS analysis of twofold diluted urines, urinary solid-phase extracts and urinary liquid-liquid extracts is shown to provide much improved sensitivity compared to hydrodynamic injection of these samples. With electroinjection from diluted urine and urinary solid-phase extracts, the presence of free opioids and their glucuronic acid conjugates can be unambiguously confirmed in urines that were collected after single-dose administration of small amounts of opioids (tested with about 7 mg codeine and 25 mg dihydrocodeine, respectively). Thus, CE-multiple MS with direct electroinjection of opioids from untreated urines could prove to become a rapid and simple approach for unambiguous urinary testing of drug abuse. Procedures leading to the reduction of siphoning in modular CE setups are briefly discussed as well.
Collapse
Affiliation(s)
- A B Wey
- Department of Clinical Pharmacology, University of Berne, Switzerland
| | | |
Collapse
|
17
|
Wey AB, Thormann W. Capillary electrophoresis-electrospray ionization ion trap mass spectrometry for analysis and confirmation testing of morphine and related compounds in urine. J Chromatogr A 2001; 916:225-38. [PMID: 11382295 DOI: 10.1016/s0021-9673(00)01096-7] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Using an aqueous background electrolyte containing 25 mM ammonium acetate and NH3 (pH 9), CE-tandem MS and CE-triple MS with atmospheric pressure electrospray ionization in the positive ion mode are shown to represent attractive approaches for analysis and confirmation testing of morphine (MOR) and related opioids in human urine. Injection of plain or diluted urine permits monitoring of solutes at concentrations above 2-5 microg/ml. For the recognition of lower concentrations, solute extraction and concentration is required. Liquid-liquid extraction at alkaline pH is shown to be suitable for analysis of free opioids only whereas solid-phase extraction using a mixed-mode polymer phase is demonstrated to permit analysis of both free and glucuronidated opioids. The former sample preparation approach, however, requires about half of the time only. Commencing with 2 ml of urine, reconstitution to provide a sample volume of 0.2 ml and hydrodynamic sample injection, detection limits for free opioids are shown to be on the 100-200 ng/ml drug level. Much improved (ppb) sensitivity is obtained by infusing the extract directly into the source of the MS system. However, solutes that produce equal fragments (such as the two glucuronides of MOR) can thereby not be distinguished. CE-tandem MS and CE-triple MS are demonstrated to be suitable to confirm the presence of MOR, MOR-3-glucuronide, 6-monoacetylmorphine, codeine, codeine-6-glucuronide, dihydrocodeine, methadone and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine in a toxicological quality control urine. The same is shown for selected metabolites of codeine and dihydrocodeine in urines collected after administration of pharmaceutical preparations.
Collapse
Affiliation(s)
- A B Wey
- Department of Clinical Pharmacology, University of Berne, Switzerland
| | | |
Collapse
|
18
|
Elgstoen KB, Zhao JY, Anacleto JF, Jellum E. Potential of capillary electrophoresis, tandem mass spectrometry and coupled capillary electrophoresis–tandem mass spectrometry as diagnostic tools. J Chromatogr A 2001; 914:265-75. [PMID: 11358221 DOI: 10.1016/s0021-9673(00)01117-1] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Urine and blood samples from patients with known metabolic disorders have been analyzed by CE, MS-MS and CE-MS-MS. For the identification of defects in acylcarnitine metabolism, blood spots on filter paper were analyzed using an MS-MS "neonatal screening" approach. Direct CE-MS-MS analysis was used for the analysis of urine samples from patients with different metabolic disorders, including galactosemia, neuroblastoma, Zellweger syndrome, propionic acidemia and alcaptonuria. The sensitivity of the CE-MS-MS method was increased by use of multiple reaction monitoring.
Collapse
Affiliation(s)
- K B Elgstoen
- Institute of Clinical Biochemistry, Rikshospitalet, Oslo, Norway.
| | | | | | | |
Collapse
|
19
|
Zaugg S, Zhang X, Sweedler J, Thormann W. Determination of salicylate, gentisic acid and salicyluric acid in human urine by capillary electrophoresis with laser-induced fluorescence detection. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2001; 752:17-31. [PMID: 11254191 DOI: 10.1016/s0378-4347(00)00507-7] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Acetylsalicylic acid (Aspirin) is rapidly metabolized to salicylic acid (salicylate) and other compounds, including gentisic acid and salicyluric acid. Monitoring of salicylate and its metabolites is of toxicological, pharmacological and biomedical interest. Three capillary electrophoresis (CE) methods featuring alkaline aqueous buffers, laser-induced fluorescence (LIF) detection and no solute extraction or derivatization have been explored. A competitive binding, electrokinetic capillary-based immunoassay is developed that recognizes the presence of salicylate and gentisic acid in urine. Differentiation of the two compounds, however, is problematic. With appropriate ultraviolet excitation, many salicylate-related compounds are fluorescent so that CE with direct urine injection and LIF detection permits the determination of salicylate, gentisic acid and salicyluric acid. Using a HeCd laser with 325 nm produces interference-free monitoring of all three compounds. Using 257 nm excitation from a frequency doubled Ar ion laser, native fluorescence of an endogenous urinary compound that co-migrates with gentisic acid is observed. With wavelength-resolved fluorescence detection, however, the two substances are distinguished. Furthermore, this technique, with comparison to literature data, permits the putative assignment of several peaks to other salicylate metabolites, namely glucuronide conjugates of salicylate and salicyluric acid. All three CE-LIF techniques have been applied to toxicological patient urines and urines collected after ingestion of 500 mg acetylsalicylic acid. CE results compare favorably with those obtained by a commercial fluorescence polarization immunoassay and by a conventional photometric assay.
Collapse
Affiliation(s)
- S Zaugg
- Department of Clinical Pharmacology, University of Bern, Switzerland
| | | | | | | |
Collapse
|
20
|
Abstract
This review covers the progress and developments in the field of capillary electrophoresis immunoassay (CEIA) over the past three years. Because many excellent descriptions of the principles of these methods are available (e.g., in the reviews listed in this article), no elementary introduction is given to the field of immunoassays (IAs) or CEIAs. This report focuses exclusively on experimental results, dividing the CEIA papers into the categories of direct, indirect, and microchip electrophoretic immunoassays. In the last section, a brief summary of the current status of the CEIA field is presented.
Collapse
Affiliation(s)
- D Schmalzing
- Whitehead Institute for Biomedical Research, Cambridge, MA 02142, USA.
| | | | | |
Collapse
|
21
|
Wey AB, Caslavska J, Thormann W. Analysis of codeine, dihydrocodeine and their glucuronides in human urine by electrokinetic capillary immunoassays and capillary electrophoresis-ion trap mass spectrometry. J Chromatogr A 2000; 895:133-46. [PMID: 11105855 DOI: 10.1016/s0021-9673(00)00636-1] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Screening for and confirmation of illicit, abused and banned drugs in human urine is a timely topic in which capillary separation techniques play a key role. Capillary electrophoresis (CE) represents the newest technology employed in this field of analysis. Two rapid competitive binding, electrokinetic capillary-based immunoassays are shown to be capable of recognizing the presence, but not the identity, of urinary opioids, namely codeine (COD), codeine-6-glucuronide, dihydrocodeine (DHC), dihydrocodeine-6-glucuronide, morphine (MOR), morphine-3-glucuronide and ethylmorphine (EMOR). In these approaches, aliquots of urine and immunoreagents of a commercial, broadly cross-reacting fluorescence polarization immunoassay for opiates were combined and analyzed by capillary zone electrophoresis or micellar electrokinetic capillary chromatography with laser induced fluorescence detection. With the fluorescent tracer solution employed, the former method is shown to provide simple electropherograms which are characterized by an opioid concentration dependent magnitude of the free tracer peak. In presence of dodecyl sulfate micelles, however, two tracer peaks with equal opioid concentration sensitivity are monitored. These data suggest the presence of two fluorescent tracers which react competitively with the urinary opioids for the binding sites of the antibody. Assay sensitivities for COD and MOR are comparable (10 ng/ml), whereas those for DHC and EMOR are about four-fold lower. Furthermore, glucuronides are shown to react like the corresponding free opioids. Analysis of urines that were collected after administration of 7 mg COD and 25 mg DHC tested positively in both assay formats. The presence of the free and conjugated codeinoids in these urines and their identification was accomplished by capillary electrophoresis-ion trap mass spectrometry (CE-MS). This confirmatory assay is based upon solid-phase extraction using a mixed-mode polymer cartridge followed by CE hyphenated to the LCQ mass spectrometer with electrospray ionization in the positive ion mode. With this technology, MS2 is employed for proper identification of COD (m/z 300.4) and DHC (m/z 302.4) whereas MS3 provides unambiguous identification of the glucuronides of COD (m/z 476.5) and DHC (m/z 478.5) via their fragmentation to COD and DHC, respectively. MSn (n > or = 2) is shown to be capable of properly identifying the urinary codeinoids on the 100-200 ng/ml concentration level.
Collapse
Affiliation(s)
- A B Wey
- Department of Clinical Pharmacology, University of Berne, Switzerland
| | | | | |
Collapse
|
22
|
Abstract
A rapid, sensitive method for the determination of morphine and amphetamine was developed using capillary zone electrophoresis coupled with electrospray interface (ESI), ion-trap tandem mass spectrometry (CE-ESI-MS2). Morphine and amphetamine were separated in 20 mM ammonium acetate buffer (pH 6.6) and detected by ion-trap mass detector in different analytical time segments (0-6.25 min for amphetamine and 6.25-12.0 min for morphine) in which the tune file for each compound was used separately. Molecular ions of morphine (m/z 286) and amphetamine (m/z 136) were detected at 5.77 and 6.83 min, respectively, while product ions of MS2 for each compound (m/z 229, 201 for morphine and m/z 119 for amphetamine) were detected almost exactly at the same time with their parent compounds. The limits of detection (LOD) for MS2 determination were 30 and 50 ng/mL for amphetamine and morphine, respectively, with an S/N ratio of 3. For more sensitive detection of morphine, the sample was injected for a longer time (i.e., 80 s) and hydrodynamically transported into a CE capillary for MS detection. Morphine and its product ion appear at 0.36 and 0.39 min on the ion chromatogram, respectively, with a five-fold increase of detection sensitivity (LOD, 10 ng/mL). The CE-MS system thus established was further applied for forensic urine samples screened as morphine-positive by fluorescence polarization immunoassay (FPIA). These results indicated the feasibility of CE-ESI-MS2 for confirmative testing of morphine in urine sample.
Collapse
Affiliation(s)
- J L Tsai
- Graduate Institute of Occupational Safety and Health, Kaohsiung Medical University, Taiwan.
| | | | | |
Collapse
|
23
|
Ortelli D, Rudaz S, Chevalley AF, Mino A, Deglon JJ, Balant L, Veuthey JL. Enantioselective analysis of methadone in saliva by liquid chromatography-mass spectrometry. J Chromatogr A 2000; 871:163-72. [PMID: 10735296 DOI: 10.1016/s0021-9673(99)01001-8] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Saliva was tested and evaluated as a biological matrix for methadone (Mtd) monitoring. Conventional method using a narrow bore C18 column, and an enantioselective method using a narrow bore alpha1-acid glycoprotein column, were developed using liquid chromatography coupled with a mass spectromeric (MS) detector. After optimisation of MS conditions by flow injection analysis, selected ion monitoring detection was used to enhance sensitivity. The total Mtd concentration and the enantiomeric ratio in saliva were validated using an experimental design. The methods were applied to samples provided by heroin addicts undergoing a Mtd treatment. Results on total Mtd determination showed a very poor correlation between saliva and serum, whereas the enantiomeric ratios of Mtd gave a very good one.
Collapse
Affiliation(s)
- D Ortelli
- Laboratory of Pharmaceutical Analytical Chemistry, University of Geneva, Switzerland
| | | | | | | | | | | | | |
Collapse
|
24
|
Chapter 1 Opiate agonists. ACTA ACUST UNITED AC 2000. [DOI: 10.1016/s1567-7192(00)80051-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
25
|
Thormann W, Caslavska J, Ramseier A, Siethoff C. Multianalyte capillary electrophoresis assays for screening and confirmation of urinary drugs of abuse. ACTA ACUST UNITED AC 2000. [DOI: 10.1002/(sici)1520-667x(2000)12:1<13::aid-mcs3>3.0.co;2-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
26
|
Ramseier A, Siethoff C, Caslavska J, Thormann W. Confirmation testing of amphetamines and designer drugs in human urine by capillary electrophoresis-ion trap mass spectrometry. Electrophoresis 2000; 21:380-7. [PMID: 10675019 DOI: 10.1002/(sici)1522-2683(20000101)21:2<380::aid-elps380>3.0.co;2-l] [Citation(s) in RCA: 57] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Monitoring of amphetamines and designer drugs in human urine is a timely topic in clinical toxicology, surveillance of drug substitution, forensic science, drug testing at the workplace, and doping control. Confirmation testing of urinary amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA, Ecstasy) and 3,4-methylenedioxyamphetamine (MDA) by capillary electrophoresis (CE) combined with atmospheric pressure electrospray ionization and ion trap mass spectrometry (MS) is described. Using an aqueous pH 4.6 buffer composed of ammonium acetate/acetic acid, CE-MS and CE-MS2 provided data that permitted the unambiguous confirmation of these drugs in external quality control urines. Furthermore, other drugs of abuse present in alkaline urinary extracts, including methadone and morphine, could also be monitored. The data presented illustrate that the sensitivity achieved with the benchtop MS is comparable to that observed by CE with UV absorption detection. CE-MS2 is further shown to be capable of identifying comigrating compounds, including the comigration of amphetamine with nicotine.
Collapse
Affiliation(s)
- A Ramseier
- Department of Clinical Pharmacology, University of Bern, Switzerland
| | | | | | | |
Collapse
|
27
|
Heegaard NH, Kennedy RT. Identification, quantitation, and characterization of biomolecules by capillary electrophoretic analysis of binding interactions. Electrophoresis 1999; 20:3122-33. [PMID: 10596820 DOI: 10.1002/(sici)1522-2683(19991001)20:15/16<3122::aid-elps3122>3.0.co;2-m] [Citation(s) in RCA: 110] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The high resolving power of capillary electrophoresis combined with the specificity of binding interactions may be used with advantage to characterize the structure-function relationship of biomolecules, to quantitate specific analytes in complex sample matrices, and to determine the purity of pharmaceutical and other molecules. We here review recent and innovative methodologies and applications of high resolution affinity electrophoresis within the fields of binding constant determination, structure-activity studies, quantitative microassays, analysis of drug purity and protein conformation, and immobilized affinity ligands. Despite the virtues of these approaches with respect to applicability, resolving power, speed, and low sample consumption, problems remain with respect to analyte identification and low concentration limits of detection. The ongoing development of new detector technologies for capillary electrophoresis such as mass spectrometry, and possibly nuclear magnetic resonance and other spectroscopic methods, is therefore very promising for the continued increased use of affinity capillary electrophoresis.
Collapse
Affiliation(s)
- N H Heegaard
- Department of Autoimmunology, Statens Serum Institut, Copenhagen, Denmark.
| | | |
Collapse
|
28
|
Thormann W, Wey AB, Lurie IS, Gerber H, Byland C, Malik N, Hochmeister M, Gehrig C. Capillary electrophoresis in clinical and forensic analysis: recent advances and breakthrough to routine applications. Electrophoresis 1999; 20:3203-36. [PMID: 10596826 DOI: 10.1002/(sici)1522-2683(19991001)20:15/16<3203::aid-elps3203>3.0.co;2-e] [Citation(s) in RCA: 54] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
This paper is a comprehensive review article on capillary electrophoresis (CE) in clinical and forensic analysis. It is based upon the literature of 1997 and 1998, presents CE examples in major fields of application, and provides an overview of the key achievements encountered, including those associated with the analysis of drugs, serum proteins, hemoglobin variants, and nucleic acids. For CE in clinical and forensic analysis, the past two years witnessed a breakthrough to routine applications. As most coauthors of this review are associated with diagnostic or forensic laboratories now using CE on a routine basis, this review also contains data from routine applications in drug, protein, and DNA analysis. With the first-hand experience of providing analytical service under stringent quality control conditions, aspects of quality assurance, assay specifications for clinical and forensic CE and the pros and cons of this maturing, cost-and pollution-controlled age technology are also discussed.
Collapse
Affiliation(s)
- W Thormann
- Department of Clinical Pharmacology, University of Bern, Switzerland.
| | | | | | | | | | | | | | | |
Collapse
|
29
|
Kwak ES, Esquivel S, Gomez FA. Optimization of capillary electrophoresis conditions for in-capillary enzyme-catalyzed microreactions. Anal Chim Acta 1999. [DOI: 10.1016/s0003-2670(99)00403-1] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
30
|
Boone CM, Waterval JC, Lingeman H, Ensing K, Underberg WJ. Capillary electrophoresis as a versatile tool for the bioanalysis of drugs--a review. J Pharm Biomed Anal 1999; 20:831-63. [PMID: 10746954 DOI: 10.1016/s0731-7085(99)00088-6] [Citation(s) in RCA: 65] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
This review article presents an overview of current research on the use of capillary electrophoretic techniques for the analysis of drugs in biological matrices. The principles of capillary electrophoresis and its various separation and detection modes are briefly discussed. Sample pretreatment methods which have been used for clean-up and concentration are discussed. Finally, an extensive overview of bioanalytical applications is presented. The bioanalyses of more than 200 drugs have been summarised, including the applied sample pretreatment methods and the achieved detection limits.
Collapse
Affiliation(s)
- C M Boone
- Department of Analytical Chemistry and Toxicology, University Center for Pharmacy, Groningen, The Netherlands.
| | | | | | | | | |
Collapse
|
31
|
Rudaz S, Ortelli D, Gex-Fabry M, Déglon JJ, Balant L, Veuthey JL. Development of validated stereoselective methods for methadone determination in clinical samples. Chirality 1999; 11:487-94. [PMID: 10419284 DOI: 10.1002/(sici)1520-636x(1999)11:5/6<487::aid-chir22>3.0.co;2-3] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A stereoselective analysis of methadone (Mtd) in whole blood and serum was developed using liquid chromatography on a protein based chiral stationary phase. Liquid-liquid extraction (LLE) and solid phase extraction methods were applied before chromatographic analysis. The extraction procedure, as well as the choice of the biological matrix, showed significant differences in the extraction yield and in the precision of the assays. Serum was selected for this assay and LLE was chosen as the preparation step because of its simplicity and rapidity. The total procedure was validated and applied to clinical samples. Samples taken from 45 heroin-addicted patients were analyzed. A correlation was found between the dose administered and Mtd concentration (total and R-form), but interindividual variability of the total normalized Mtd was seen (concentration varied from 90 to 530 ng/ml). Furthermore, two populations were apparently observed with a mean Mtd concentration of 200 and 475 ng/ml, respectively. Stereoselective analyses showed that more than 50% of the patients presented a nonracemic ratio, and particularly about 25% showed a preferential metabolism of the active R-Mtd enantiomer. Therefore, the stereoselective determination of Mtd is necessary to improve the quality of the treatment of heroin addiction.
Collapse
Affiliation(s)
- S Rudaz
- Laboratory of Pharmaceutical Analytical Chemistry, University of Geneva, Switzerland
| | | | | | | | | | | |
Collapse
|
32
|
Affiliation(s)
- T A Brettell
- Forensic Science Bureau, New Jersey State Police, West Trenton 08625, USA
| | | | | | | |
Collapse
|
33
|
Caslavska J, Allemann D, Thormann W. Analysis of urinary drugs of abuse by a multianalyte capillary electrophoretic immunoassay. J Chromatogr A 1999; 838:197-211. [PMID: 10327639 DOI: 10.1016/s0021-9673(99)00115-6] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
This paper characterizes a novel multianalyte competitive binding, electrokinetic capillary-based immunoassay for urinary methadone, opiates, benzoylecgonine (cocaine metabolite) and amphetamines. After incubation of 25 microliters urine with the reactants for several minutes in the presence of an internal standard, a small aliquot of the mixture is applied onto a fused-silica capillary and the unbound fluorescein labelled drug tracers are monitored by capillary electrophoresis with on-column laser induced fluorescence detection. The multianalyte assay is shown to be rapid, simple, quantitative, capable of recognizing urinary drug concentrations > or = 30 ng/ml and suitable for screening of patient urines. Data are demonstrated to compare well with those obtained by routine screening methods based on enzyme multiplied immunoassay techniques and fluorescence polarization immunoassays. The electrokinetic capillary assay has been validated via analysis of external quality control urines and confirmation analysis of patient urines using GC-MS.
Collapse
Affiliation(s)
- J Caslavska
- Department of Clinical Pharmacology, University of Bern, Switzerland
| | | | | |
Collapse
|
34
|
Kok SJ, Velthorst NH, Gooijer C, Brinkman UA. Analyte identification in capillary electrophoretic separation techniques. Electrophoresis 1998; 19:2753-76. [PMID: 9870373 DOI: 10.1002/elps.1150191604] [Citation(s) in RCA: 23] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
A review on applications of on-line hyphenation in capillary electrophoresis and capillary electrochromatography for the identification of migrating analytes is presented. There is an urgent need for unambiguous analyte identification by combining spectral information and observed migration times, because the parameters influencing the migration times and separation efficiencies in these separation techniques are not easily controlled, especially when real samples containing unknown interferences have to be analyzed. The spectrometric techniques covered here are ultraviolet and visible radiation (UV/Vis) absorption, fluorescence including fluorescence line-narrowing spectroscopy, Raman spectroscopy, nuclear magnetic resonance and mass spectrometry. Attention is essentially confined to literature reports in which the extra information provided by the detector is really used for identification purposes, especially in real-life samples, while the interfacing as such and analyte detectabilities in standard solutions are only briefly discussed. This article covers an extensive fraction of the literature published on this topic until the beginning of 1998.
Collapse
Affiliation(s)
- S J Kok
- Vrije Universiteit Amsterdam, Department of General and Analytical Chemistry, The Netherlands
| | | | | | | |
Collapse
|
35
|
Choi J, Kim C, Choi MJ. Comparison of capillary electrophoresis-based immunoassay with fluorescence polarization immunoassay for the immunodetermination of methamphetamine using various methamphetamine antibodies. Electrophoresis 1998; 19:2950-5. [PMID: 9870395 DOI: 10.1002/elps.1150191626] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
An accurate and simple immunoassay using capillary electrophoresis (CE) with laser-induced fluorescence (LIF) was performed for the detection of methamphetamine (MA) in urine. The CE-LIF was conducted with an untreated fused-silica column using antiserum and a tracer of fluorescein isothiocyanate (FITC)-labeled MA. This CE-LIF system was compared with fluorescence polarization immunoassay (FPIA) in a TDx analyzer in the photo-check mode using the same FITC-labeled tracer and the same antiserum. Various antibodies, not only those prepared by our own immunogens but also those from commercial sources, were screened and characterized in both assay systems with regard to sensitivity, precision, and cross-reactivity. Both systems satisfied analytical precision and gave similar cross-reactivity patterns. However, the CE-LIF-based immunoassay was approximately one order superior to FPIA in sensitivity, requiring less volume of sample, antiserum, and tracer for the assay. Considering that the FPIA system is well known to be a useful tool for screening antibodies and detecting drugs, the CE-LIF-based immunoassay system, which is seemingly more advantageous than the FPIA system, appears to have great power for the characterization of antibodies and for the detection of MA in urine.
Collapse
Affiliation(s)
- J Choi
- Bioanalysis and Biotransformation Research Center, Korea Institute of Science and Technology, Cheongryang, Seoul.
| | | | | |
Collapse
|
36
|
Ramseier A, Caslavska J, Thormann W. Screening for urinary amphetamine and analogs by capillary electrophoretic immunoassays and confirmation by capillary electrophoresis with on-column multiwavelength absorbance detection. Electrophoresis 1998; 19:2956-66. [PMID: 9870396 DOI: 10.1002/elps.1150191627] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
This paper characterizes competitive binding, electrokinetic capillary-based immunoassays for screening of urinary amphetamine (A) and analogs using reagents which were commercialized for a fluorescence polarization immunoassay (FPIA). After incubation of 25 microL urine with the reactants, a small aliquot of the mixture is applied onto a fused-silica capillary and unbound fluorescein-labeled tracer compounds are monitored by capillary electrophoresis with on-column laser-induced fluorescence detection. Configurations in presence and absence of micelles were investigated and found to be capable of recognizing urinary D-(+)-amphetamine at concentrations > about 80 ng/mL. Similar responses were obtained for racemic methamphetamine (MA) and 3,4-methylenedioxymethamphetamine (MDMA). The electrokinetic immunoassay data suggest that the FPIA reagent kit includes two immunoassay systems (two antibodies and two tracer molecules), one that recognizes MA and MDMA, and one that is geared towards monitoring of A. For confirmation analysis of urinary amphetamines and ephedrines, capillary electrophoresis in a pH 9.2 buffer and multiwavelength UV detection was employed. The suitability of the electrokinetic methods for screening and confirmation is demonstrated via analysis of patient and external quality control urines.
Collapse
Affiliation(s)
- A Ramseier
- Department of Clinical Pharmacology, University of Bern, Switzerland
| | | | | |
Collapse
|
37
|
Abstract
During the past decade, capillary electrophoresis (CE) emerged as a promising, effective and economic approach for separation of a large variety of substances, including those encountered in clinical toxicology. Reliable and automated CE instruments became commercially available and promoted the exploration of an increasing number of CE methods for illicit and licit drugs in body fluids. The widespread applicability of CE, its enormous separation power and high-sensitivity detection schemes make this technology an attractive and promising tool. This review provides an overview of the key achievements encountered with CE in clinical toxicology, including (i) the rapid assessment of drug intoxications via direct sample injection, (ii) the screening for and determination of illicit and licit drugs in body fluids with drug extraction, drug concentration (stacking) and chiral discrimination, (iii) the application of immunological single and multianalyte assays in the capillary format to the screening for drugs in body fluids, and (iv) drug confirmation by on-column multiwavelength absorbance and fluorescence detection and/or CE coupled to mass spectrometry. With its distinct features (automation, small sample size, minimal sample preparation, requirement of almost no organic solvents, ease of buffer change and method development, speed of analysis, low cost of capillaries and chemicals) CE has a bright future and the twenty-first century will witness the widespread use of a large number of simple and reliable CE based assays for drugs, methods that will be employed in clinical toxicology, therapeutic drug monitoring and forensic science.
Collapse
Affiliation(s)
- W Thormann
- Department of Clinical Pharmacology, University of Bern, Switzerland.
| | | | | | | |
Collapse
|