1
|
Shi H, Jiang S, Liu B, Liu Z, Reis NM. Modern microfluidic approaches for determination of ions. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106845] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
2
|
Buking S, Suedomi Y, Nacapricha D, Kaneta T. Characterization of Pieces of Paper That Form Reagent Containers for Use as Portable Analytical Devices. ACS OMEGA 2019; 4:15249-15254. [PMID: 31552371 PMCID: PMC6751694 DOI: 10.1021/acsomega.9b02226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Accepted: 08/21/2019] [Indexed: 06/10/2023]
Abstract
Reagent-deposited pieces of paper were characterized by the use of a compact conductometer, a compact pH sensor, and a conventional spectrophotometer to assess their suitability for use as reagent containers. The pieces of paper were fabricated by wax printing to form a limited hydrophilic area to which a consistent volume of an aqueous reagent could be added. The pieces of paper without the reagent increased the conductivity of water gradually because of the release of sodium salts, whereas pH of NaOH decreased because of the acidity of the functional groups in the paper. Three reagents, sulfamic acid as an acid, Na2CO3 as a base, and BaCl2 as a metal salt, were deposited on the pieces of paper to evaluate their ability to release from the pieces of paper. Sulfamic acid and Na2CO3 were released in quantities of 58 and 73% into water after 420 s, whereas 100% of BaCl2 was released after 480 s. The conductometric titrations of NaOH, HCl, and Na2SO4, and the spectrophotometry of Fe2+ were examined using the pieces of paper that contained sulfamic acid, Na2CO3, BaCl2, and 1,10-phenanthroline. Titrations using the pieces of paper suggested that the reagents were quantitatively released into the titrant, which resulted in a linear relationship between the endpoints and the equivalent points. In 120 s of soaking time, 60-70% of the reagents were released. The spectrophotometric measurements of Fe2+ indicated that when an excess amount of the reagents was deposited onto the pieces of paper, they nonetheless sufficiently fulfilled the role of a reagent container.
Collapse
Affiliation(s)
- Supatana Buking
- Flow
Innovation-Research for Science and Technology Laboratories
(FIRST Labs) and Department of Chemistry and Center of Excellence for Innovation in
Chemistry, Faculty of Science, Mahidol University, Bangkok 10400, Thailand
| | - Yusuke Suedomi
- Department
of Chemistry, Graduate School of Natural Science and Technology, Okayama University, Okayama 700-8530, Japan
| | - Duangjai Nacapricha
- Flow
Innovation-Research for Science and Technology Laboratories
(FIRST Labs) and Department of Chemistry and Center of Excellence for Innovation in
Chemistry, Faculty of Science, Mahidol University, Bangkok 10400, Thailand
| | - Takashi Kaneta
- Department
of Chemistry, Graduate School of Natural Science and Technology, Okayama University, Okayama 700-8530, Japan
| |
Collapse
|
3
|
Sharma MK, Wieringa FP, Frijns AJH, Kooman JP. On-line monitoring of electrolytes in hemodialysis: on the road towards individualizing treatment. Expert Rev Med Devices 2016; 13:933-943. [DOI: 10.1080/17434440.2016.1230494] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Affiliation(s)
- Manoj K. Sharma
- Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Fokko P. Wieringa
- TNO Science & Industry, Division of Medical Equipment, Delft, Netherlands
- Faculty of Health, Medicine and Life Sciences, Maastricht University, Maastricht, Netherlands
| | - Arjan J. H. Frijns
- Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Jeroen P. Kooman
- Department of Internal Medicine, Division of Nephrology, University Hospital Maastricht, Maastricht, Netherlands
| |
Collapse
|
4
|
Breitbach ZS, Berthod A, Huang K, Armstrong DW. Mass spectrometric detection of trace anions: The evolution of paired-ion electrospray ionization (PIESI). MASS SPECTROMETRY REVIEWS 2016; 35:201-218. [PMID: 25648413 DOI: 10.1002/mas.21448] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2014] [Revised: 05/04/2014] [Accepted: 05/04/2014] [Indexed: 06/04/2023]
Abstract
The negative-ion mode of electrospray ionization mass spectrometry (ESI-MS) is intrinsically less sensitive than the positive-ion mode. The detection and quantitation of anions can be performed in positive-ion mode by forming specific ion-pairs during the electrospray process. The paired-ion electrospray ionization (PIESI) method uses specially synthesized multifunctional cations to form positively charged adducts with the anions to be analyzed. The adducts are detected in the positive-ion mode and at higher m/z ratios to produce excellent signal-to-noise ratios and limits of detection that often are orders of magnitude better than those obtained with native anions in the negative-ion mode. This review briefly summarizes the different analytical approaches to detect and separate anions. It focuses on the recently introduced PIESI method to present the most effective dicationic, tricationic, and tetracationic reagents for the detection of singly and multiply charged anions and some zwitterions. The mechanism by which specific structural molecular architectures can have profound effects on signal intensities is also addressed.
Collapse
Affiliation(s)
- Zachary S Breitbach
- Department of Chemistry, University of Texas at Arlington, Planetarium Place, Arlington, 76019, Texas
| | - Alain Berthod
- Institute of Analytical Sciences, University of Lyon, 5 rue de la Doua, Villeurbanne, 69100, France
| | - Ke Huang
- Department of Chemistry, University of Texas at Arlington, Planetarium Place, Arlington, 76019, Texas
| | - Daniel W Armstrong
- Department of Chemistry, University of Texas at Arlington, Planetarium Place, Arlington, 76019, Texas
| |
Collapse
|
5
|
Ali I, Alharbi OML, Marsin Sanagi M. Nano-capillary electrophoresis for environmental analysis. ENVIRONMENTAL CHEMISTRY LETTERS 2015; 14:79-98. [PMID: 32214934 PMCID: PMC7087629 DOI: 10.1007/s10311-015-0547-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/04/2015] [Accepted: 12/11/2015] [Indexed: 06/10/2023]
Abstract
Many analytical techniques have been used to monitor environmental pollutants. But most techniques are not capable to detect pollutants at nanogram levels. Hence, under such conditions, absence of pollutants is often assumed, whereas pollutants are in fact present at low but undetectable concentrations. Detection at low levels may be done by nano-capillary electrophoresis, also named microchip electrophoresis. Here, we review the analysis of pollutants by nano-capillary electrophoresis. We present instrumentations, applications, optimizations and separation mechanisms. We discuss the analysis of metal ions, pesticides, polycyclic aromatic hydrocarbons, explosives, viruses, bacteria and other contaminants. Detectors include ultraviolet-visible, fluorescent, conductivity, atomic absorption spectroscopy, refractive index, atomic fluorescence spectrometry, atomic emission spectroscopy, inductively coupled plasma, inductively coupled plasma-mass spectrometry, mass spectrometry, time-of-flight mass spectrometry and nuclear magnetic resonance. Detection limits ranged from nanogram to picogram levels.
Collapse
Affiliation(s)
- Imran Ali
- Department of Chemistry, Jamia Millia Islamia (Central University), New Delhi, 110025 India
| | - Omar M. L. Alharbi
- Biology Department, Faculty of Sciences, Taibah University, P.O. Box 30002, Madinah Al-Munawarah, 41477 Saudi Arabia
| | - Mohd. Marsin Sanagi
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia (UTM), 81310 Johor Bahru, Johor Malaysia
- Ibnu Sina Institute for Fundamental Science Studies, Nanotechnology Research Alliance, Universiti Teknologi Malaysia (UTM), 81310 Johor Bahru, Johor Malaysia
| |
Collapse
|
6
|
Fibre coupled micro-light emitting diode array light source with integrated band-pass filter for fluorescence detection in miniaturised analytical systems. Anal Chim Acta 2015; 871:85-92. [DOI: 10.1016/j.aca.2015.02.044] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2014] [Revised: 02/12/2015] [Accepted: 02/15/2015] [Indexed: 10/24/2022]
|
7
|
Smejkal P, Bottenus D, Breadmore MC, Guijt RM, Ivory CF, Foret F, Macka M. Microfluidic isotachophoresis: A review. Electrophoresis 2013; 34:1493-509. [DOI: 10.1002/elps.201300021] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2013] [Revised: 03/06/2013] [Accepted: 03/07/2013] [Indexed: 12/22/2022]
Affiliation(s)
- Petr Smejkal
- ACROSS and School of Chemistry; University of Tasmania; Hobart; Australia
| | - Danny Bottenus
- Voiland School of Chemical Engineering and Bioengineering; Washington State University; Pullman; WA; USA
| | | | - Rosanne M. Guijt
- ACROSS and School of Pharmacy; University of Tasmania; Hobart; Australia
| | - Cornelius F. Ivory
- Voiland School of Chemical Engineering and Bioengineering; Washington State University; Pullman; WA; USA
| | - František Foret
- Institute of Analytical Chemistry of the Academy of Sciences of the Czech Republic; v.v.i., Brno; Czech Republic
| | - Mirek Macka
- ACROSS and School of Chemistry; University of Tasmania; Hobart; Australia
| |
Collapse
|
8
|
Masár M, Bomastyk B, Bodor R, Horčičiak M, Danč L, Troška P, Kuss HM. Determination of chloride, sulfate and nitrate in drinking water by microchip electrophoresis. Mikrochim Acta 2012. [DOI: 10.1007/s00604-012-0788-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
9
|
Shin H, Mahto SK, Kim JH, Rhee SW. Exposure of BALB/3T3 fibroblast cells to temporal concentration profile of toxicant inside microfluidic device. BIOCHIP JOURNAL 2011. [DOI: 10.1007/s13206-011-5304-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
10
|
AL-Othman ZA, Ali I. NANO CAPILLARY ELECTROPHORESIS IN MICROCHIPS: A NEED OF THE PRESENT CENTURY. J LIQ CHROMATOGR R T 2011. [DOI: 10.1080/10826076.2011.566031] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Zeid A. AL-Othman
- a Department of Chemistry, College of Science , King Saud University , Riyadh, Kingdom of Saudi Arabia
| | - Imran Ali
- b Department of Chemistry , Jamia Millia Islamia, (Central University) , New Delhi, India
| |
Collapse
|
11
|
Dennis PJ, Ferguson Welch ER, Alarie JP, Ramsey JM, Jorgenson JW. Development of a photothermal absorbance detector for use with microfluidic devices. Anal Chem 2010; 82:4063-71. [PMID: 20411923 PMCID: PMC2877626 DOI: 10.1021/ac902975r] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The development of a photothermal absorbance detector for use with microfluidic devices is described. Unlike thermo-optical techniques that rely on measuring refractive index changes, the solution viscosity is probed by continuously monitoring solution conductivity. Platinum electrodes microfabricated on a quartz substrate and bonded to a substrate containing the microchannels enable contact conductivity measurements. The effects of excitation frequency and voltage, electrode spacing, laser power, and laser modulation (chopping) frequency were evaluated experimentally. In the current configuration, a limit of detection of 5 nM for DABSYL-tagged glucosamine was obtained using long injections (to give flat-topped peaks). This corresponds to an absorbance of 4.4 x 10(-7) AU. Separation and detection of DABSYL-tagged glycine, proline, and tryptophan are also shown to demonstrate the feasibility of the method. In addition, simulations were used to investigate the applicability of the technique to small volume platforms.
Collapse
Affiliation(s)
- Patty J. Dennis
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapman Hall Room 251, Chapel Hill, North Carolina 27599-3216
| | - Erin R. Ferguson Welch
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapman Hall Room 251, Chapel Hill, North Carolina 27599-3216
| | - Jean Pierre Alarie
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapman Hall Room 251, Chapel Hill, North Carolina 27599-3216
| | - J. Michael Ramsey
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapman Hall Room 251, Chapel Hill, North Carolina 27599-3216
| | - James W. Jorgenson
- Department of Chemistry, University of North Carolina at Chapel Hill, Kenan Laboratories Room A308, Chapel Hill, North Carolina, 27599-3290
| |
Collapse
|
12
|
Goet G, Baier T, Hardt S. Micro contactor based on isotachophoretic sample transport. LAB ON A CHIP 2009; 9:3586-3593. [PMID: 20024040 DOI: 10.1039/b914466h] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
It is demonstrated how isotachophoresis (ITP) in a microfluidic device may be utilized to bring two small sample volumes into contact in a well-controlled manner. The ITP contactor serves a similar purpose as micromixers that are designed to mix two species rapidly in a microfluidic channel. In contrast to many micromixers, the ITP contactor does not require complex channel architectures and allows a sample processing in the spirit of "digital microfluidics", i.e. the samples always remain in a compact volume. It is shown that the ITP zone transport through microchannels proceeds in a reproducible and predictable manner, and that the sample trajectories follow simple relationships obtained from Ohm's law. Firstly, the micro contactor can be used to synchronize two ITP zones having reached a channel at different points in time. Secondly, fulfilling its actual purpose it is capable of bringing two samples in molecular contact via an interpenetration of ITP zones. It is demonstrated that the contacting time is proportional to the ITP zone extension. This opens up the possibility of using that type of device as a special type of micromixer with "mixing times" significantly below one second and an option to regulate the duration of contact through specific parameters such as the sample volume. Finally, it is shown how the micro contactor can be utilized to conduct a hybridization reaction between two ITP zones containing complementary DNA strands.
Collapse
Affiliation(s)
- Gabriele Goet
- Abteilung Fluidik und Simulation, Institut für Mikrotechnik Mainz, Mainz, Germany
| | | | | |
Collapse
|
13
|
Johns C, Breadmore MC, Macka M, Ryvolová M, Haddad PR. Recent significant developments in detection and method development for the determination of inorganic ions by CE. Electrophoresis 2009; 30 Suppl 1:S53-67. [DOI: 10.1002/elps.200900103] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
14
|
Shen S, Li Y, Wakida SI, Takeda S. Determination of adrenal steroids by microfluidic chip using micellar electrokinetic chromatography. ENVIRONMENTAL MONITORING AND ASSESSMENT 2009; 153:201-208. [PMID: 18551375 DOI: 10.1007/s10661-008-0349-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2007] [Accepted: 04/14/2008] [Indexed: 05/26/2023]
Abstract
This paper describes a sensitive and convenient method to separate progesterone, 17alpha-hydroxy progesterone, cortexolone, hydrocortisone and cortisone, all of which are steroids and have similar structures, using microfluidic chip-based technology with UV detection at 252 nm. We successfully obtained high-speed separation of the five steroids within 70 s in optimized microfluidic controls and micellar electrokinetic chromatography (MEKC) separation conditions. Fairly good linearity with correlation coefficient of over 0.98 from 10 or 20 to 100 mg/l steroid chemicals was obtained. The limits of detection obtained at a signal to noise ratio of 3 were from 3.89 to 7.80 mg/l. The values of the relative standard deviation (RSD) were 0.98-1.34% for repetitive injection (n = 12) and the intraday and interday RSDs were below 6%. The highly stable response reflected the feasibility of this method.
Collapse
Affiliation(s)
- Shuanglong Shen
- Department of Chemistry, Changzhi College, 73 Chengbei East Street, Changzhi, 046011 Shanxi, China
| | | | | | | |
Collapse
|
15
|
Hutchinson JP, Johns C, Breadmore MC, Hilder EF, Guijt RM, Lennard C, Dicinoski G, Haddad PR. Identification of inorganic ions in post-blast explosive residues using portable CE instrumentation and capacitively coupled contactless conductivity detection. Electrophoresis 2008; 29:4593-602. [DOI: 10.1002/elps.200800226] [Citation(s) in RCA: 80] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
16
|
Johnson RD, Gavalas VG, Daunert S, Bachas LG. Microfluidic ion-sensing devices. Anal Chim Acta 2008; 613:20-30. [DOI: 10.1016/j.aca.2008.02.041] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2007] [Revised: 02/17/2008] [Accepted: 02/25/2008] [Indexed: 10/22/2022]
|
17
|
Wu D, Qin J, Lin B. Electrophoretic separations on microfluidic chips. J Chromatogr A 2008; 1184:542-59. [PMID: 18207148 PMCID: PMC7094303 DOI: 10.1016/j.chroma.2007.11.119] [Citation(s) in RCA: 148] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2007] [Revised: 11/17/2007] [Accepted: 11/30/2007] [Indexed: 02/07/2023]
Abstract
This review presents a brief outline and novel developments of electrophoretic separation in microfluidic chips. Distinct characteristics of microchip electrophoresis (MCE) are discussed first, in which sample injection plug, joule heat, channel turn, surface adsorption and modification are introduced, and some successful strategies and recognized conclusions are also included. Important achievements of microfluidic electrophoresis separation in small molecules, DNA and protein are then summarized. This review is aimed at researchers, who are interested in MCE and want to adopt MCE as a functional unit in their integrated microsystems.
Collapse
Affiliation(s)
| | - Jianhua Qin
- Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| | - Bingcheng Lin
- Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| |
Collapse
|
18
|
Kubáň P, Hauser PC. High-performance liquid chromatography with contactless conductivity detection for the determination of peptides and proteins using a monolithic capillary column. J Chromatogr A 2007; 1176:185-91. [DOI: 10.1016/j.chroma.2007.10.109] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2007] [Revised: 10/26/2007] [Accepted: 10/31/2007] [Indexed: 01/16/2023]
|
19
|
Roman GT, Kennedy RT. Fully integrated microfluidic separations systems for biochemical analysis. J Chromatogr A 2007; 1168:170-88; discussion 169. [PMID: 17659293 DOI: 10.1016/j.chroma.2007.06.010] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2007] [Accepted: 06/05/2007] [Indexed: 10/23/2022]
Abstract
Over the past decade a tremendous amount of research has been performed using microfluidic analytical devices to detect over 200 different chemical species. Most of this work has involved substantial integration of fluid manipulation components such as separation channels, valves, and filters. This level of integration has enabled complex sample processing on miniscule sample volumes. Such devices have also demonstrated high throughput, sensitivity, and separation performance. Although the miniaturization of fluidics has been highly valuable, these devices typically rely on conventional ancillary equipment such as power supplies, detection systems, and pumps for operation. This auxiliary equipment prevents the full realization of a "lab-on-a-chip" device with complete portability, autonomous operation, and low cost. Integration and/or miniaturization of ancillary components would dramatically increase the capability and impact of microfluidic separations systems. This review describes recent efforts to incorporate auxiliary equipment either as miniaturized plug-in modules or directly fabricated into the microfluidic device.
Collapse
Affiliation(s)
- Gregory T Roman
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109-1055, USA
| | | |
Collapse
|
20
|
Timerbaev AR. Recent trends in CE of inorganic ions: From individual to multiple elemental species analysis. Electrophoresis 2007; 28:3420-35. [PMID: 17768723 DOI: 10.1002/elps.200600491] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
The major methodological developments in CE related to inorganic analysis are overviewed. This is an update to a previous review article by the author (Timerbaev, A. R., Electrophoresis 2004, 25, 4008-4031) and it covers the review work and innovative research papers published between January 2004 and the first part of 2006. As was underlined in that review, a growing interest of analytical community in providing elemental speciation information found a sound response of the CE method developers. Presently, almost every second research paper in the field of interest deals with element species analysis, the use of inductively coupled plasma MS detection and biochemical applications being the topics of utmost research efforts. On the other hand, advances in general methodology traditionally centered on a CE system modernization for improvements in sensitivity and separation selectivity have attracted less attention over the review period. While there is no indication that inorganic ion applications would surpass by the developmental rate the more matured analysis of organic analytes, CE can now be seen as an analytical technique to be before long customary in a number of inorganic analysis arenas.
Collapse
Affiliation(s)
- Andrei R Timerbaev
- Vernadsky Institute of Geochemistry and Analytical Chemistry, Russian Academy of Sciences, Moscow, Russia.
| |
Collapse
|
21
|
Chen R, Cheng H, Wu W, Ai X, Huang W, Wang Z, Cheng J. Analysis of inorganic and small organic ions by CE with amperometric detection. Electrophoresis 2007; 28:3347-61. [PMID: 17847134 DOI: 10.1002/elps.200700249] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Capillary electrophoresis has become a widely useful analytical technology. Amperometric detection is extensively employed in capillary electrophoresis for its many inherent virtues, such as rapid response, remarkable sensitivity, and low cost of both detectors and instrumentations. Analysis of inorganic and small organic ions by capillary electrophoresis is an important research field. This review focuses on the recent developments of capillary electrophoresis coupled with amperometric detection for analysis of inorganic and small organic ions. Advancements in electrophoresis separation modes, amperometric detection modes, working electrodes, and applications of inorganic ions, amino acids, phenols, and amines are discussed.
Collapse
Affiliation(s)
- Rongsheng Chen
- Department of Chemistry, Wuhan University, Wuhan 430072, P. R. China
| | | | | | | | | | | | | |
Collapse
|
22
|
Destandau E, Lefèvre JP, Chouai Fakhr Eddine A, Desportes S, Jullien MC, Hierle R, Leray I, Valeur B, Delaire JA. A novel microfluidic flow-injection analysis device with fluorescence detection for cation sensing. Application to potassium. Anal Bioanal Chem 2007; 387:2627-32. [PMID: 17287929 DOI: 10.1007/s00216-007-1132-3] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2006] [Revised: 01/11/2007] [Accepted: 01/15/2007] [Indexed: 10/23/2022]
Abstract
A microfabricated device has been developed for fluorimetric detection of potassium ions without previous separation. It is based on use of a fluorescent molecular sensor, calix-bodipy, specially designed to be sensitive to and selective for the target ion. The device is essentially made of a Y-shape microchannel moulded in PDMS fixed on a glass substrate. A passive mixer is used for mixing the reactant and the analyte. The optical detection arrangement uses two optical fibres, one for excitation by a light-emitting diode, the other for collection of the fluorescence. This system enabled the flow-injection analysis of the concentration of potassium ions in aqueous solutions with a detection limit of 0.5 mmol L(-1) and without interference with sodium ions. A calibration plot was constructed using potassium standard solutions in the range 0-16 mmol L(-1), and was used for the determination of the potassium content of a pharmaceutical pill. Figure Photography of the microfluidic channel showing the ridges in the PDMS substrate at the top of the channel.
Collapse
Affiliation(s)
- Emilie Destandau
- D'Alembert Institute, ENS de Cachan, 61 avenue du Président Wilson, 94235 Cachan Cedex, France
| | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Abstract
ITP has been attracting constant attention for many years due to its principal capability to concentrate trace analytes by several orders of magnitude. In the current capillary format, it is able to concentrate trace analytes diluted to several microliters of an original sample into concentrated zones having volumes in the range of picoliters. Due to this reason, ITP holds an important position in many current multistage and multidimensional separation schemes. This article links up previous reviews on the topic and summarizes the progress of analytical capillary ITP since 2002. Almost 100 papers are reviewed that include methodological novelties, instrumental aspects, and analytical applications. Papers using ITP and/or isotachophoretic principles as part of multistage and/or multidimensional separation schemes are also included.
Collapse
Affiliation(s)
- Petr Gebauer
- Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Brno, Czech Republic
| | | | | |
Collapse
|
24
|
Thompson M, Compton RG. Voltammetric Monitoring of Transient Hydrodynamic Flow Profiles in Microfluidic Flow Cells. Anal Chem 2006; 79:626-31. [PMID: 17222029 DOI: 10.1021/ac0612022] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We consider the transition to steady-state flow in the inlet region of a hydrodynamic channel cell and show that a microelectrode positioned within this inlet region allows chronoamperometric results to be recorded, from which information about the extent of the development of the flow profile may be deduced as well as information about the precise dimensions of the microfluidic channel.
Collapse
Affiliation(s)
- Mary Thompson
- Physical and Theoretical Chemistry Laboratory, Oxford University, South Parks Road, Oxford OX1 3QZ, United Kingdom
| | | |
Collapse
|
25
|
Petr J, Maier V, Horáková J, Sevcík J, Stránský Z. Capillary isotachophoresis from the student point of view – images and the reality. J Sep Sci 2006; 29:2705-15. [PMID: 17305231 DOI: 10.1002/jssc.200600249] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A review of some fundamental aspects of ITP from the student point of view, imaginations of some basic facts and laws, use of ITP, and the recent trends are presented. The results of theoretical computations of ITP separation processes are added for comparison of imaginations with the exact mathematical description.
Collapse
Affiliation(s)
- Jan Petr
- Department of Analytical Chemistrý, Palackỳ University, Trída Svobody 8, Olomouc, Czech Republic.
| | | | | | | | | |
Collapse
|
26
|
Schaller D, Hilder EF, Haddad PR. Monolithic stationary phases for fast ion chromatography and capillary electrochromatography of inorganic ions. J Sep Sci 2006; 29:1705-19. [PMID: 16970181 DOI: 10.1002/jssc.200600169] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The focus of this review is on current developments in monolithic stationary phases for the fast analysis of inorganic ions and other small molecules in ion chromatography (IC) and capillary electrochromatography (CEC), concentrating in particular on the properties of organic (polymer) monolithic materials in comparison to inorganic (silica-based) monoliths. The applicability of these materials for fast IC is discussed in the context of recent publications, including the range of synthesis and modification procedures described. While commercial monolithic silica columns already show promising results on current IC instrumentation, polymer-based monolithic stationary phases are currently predominantly used in the capillary format on modified micro-IC systems. However, they are beginning to find application in IC particularly under high pH conditions, with the potential to replace their particle-packed counterparts.
Collapse
Affiliation(s)
- David Schaller
- Australian Centre for Research on Separation Science (ACROSS), School of Chemistry, University of Tasmania, Hobart, Tasmania, Australia
| | | | | |
Collapse
|
27
|
Dabek-Zlotorzynska E, Celo V. Recent advances in capillary electrophoresis and capillary electrochromatography of pollutants. Electrophoresis 2006; 27:304-22. [PMID: 16315167 DOI: 10.1002/elps.200500547] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Recent advances in the CE and CEC separation, detection, and sample preparation methodologies applied to the determination of a variety of compounds having current or potential environmental relevance have been overviewed. The reviewed literature has illustrated the wide range of CE applications, indicating the continuing interest in CE and CEC in the environmental field.
Collapse
Affiliation(s)
- Ewa Dabek-Zlotorzynska
- Analysis and Air Quality Division, Environmental Technology Centre, Environment Canada, Ottawa, Ontario, Canada.
| | | |
Collapse
|
28
|
Wakida SI, Fujimoto K, Nagai H, Miyado T, Shibutani Y, Takeda S. On-chip micellar electrokinetic chromatographic separation of phenolic chemicals in waters. J Chromatogr A 2006; 1109:179-82. [PMID: 16504203 DOI: 10.1016/j.chroma.2006.02.009] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2005] [Revised: 02/07/2006] [Accepted: 02/08/2006] [Indexed: 10/24/2022]
Abstract
This paper describes on-chip micellar electrokinetic chromatography (MEKC) separation of bisphenol A and 3 kinds of alkylphenols, which have been recently recognized as endocrine disrupting chemicals for fish by the Japanese government, using microchip capillary electrophoresis with UV detection. We successfully obtained high-speed separation of the phenolic chemicals within 15 s as optimizing in microfluidic controls and MEKC separation conditions. We obtained fairly good linearity with correlation coefficient of over 0.98 from 0 to 50 mg/l phenolic chemicals except for 4-nonylphenol, which sample is the mixture of many geometrical isomers (r = 0.86). The values of the relative standard deviation for peak height in 50 mg/l phenolic chemicals were less than 8% except for bisphenol A (11.0%). The limits of detection obtained at a signal-to-noise ratio of 3 were from 5.6 to 20.0 mg/l. To realize on-site monitoring, we described strategy for on-chip MEKC analysis of the phenolic chemicals in waters using a portable analyzer based on microfluidic devices.
Collapse
Affiliation(s)
- Shin-ichi Wakida
- Human Stress Signal Research Center (HSS), National Institute of Advanced Industrial Science and Technology (AIST), 1-8-31 Midorigaoka, Ikeda, Osaka 563-8577, Japan.
| | | | | | | | | | | |
Collapse
|
29
|
Faure K, Loughran M, Glennon JD. Microchip metal complex speciation: The nickel–bathophenanthroline disulfonic acid system. Anal Chim Acta 2006. [DOI: 10.1016/j.aca.2005.10.057] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
30
|
Padarauskas A. CE determination of small ions: methods and techniques. Anal Bioanal Chem 2005; 384:132-44. [PMID: 16331445 DOI: 10.1007/s00216-005-0186-3] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2005] [Revised: 10/17/2005] [Accepted: 10/21/2005] [Indexed: 11/27/2022]
Abstract
This paper provides an overview on the current status of capillary electrophoresis (CE) in the analysis of inorganic and charged small organic species. The various CE strategies used to improve the separation of ionic analytes are summarized. Technical developments in the design of improved detection systems are described. A brief account of their advantages and limitations is given. The potential use of these devices for miniaturized CE systems is also described. Finally, special attention is focused on the on-capillary preconcentration techniques developed in attempts to overcome the poor detectability of CE. Recent review articles are frequently cited to provide readers with a source of information about pioneering work, theoretical treatments, and specific applications.
Collapse
Affiliation(s)
- Audrius Padarauskas
- Department of Analytical and Environmental Chemistry, Vilnius University, Naugarduko 24, 03225, Vilnius, Lithuania.
| |
Collapse
|
31
|
Kubán P, Hauser PC. Application of an external contactless conductivity detector for the analysis of beverages by microchip capillary electrophoresis. Electrophoresis 2005; 26:3169-78. [PMID: 16047312 DOI: 10.1002/elps.200500178] [Citation(s) in RCA: 68] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Quantitative total ionic analysis of alcoholic and nonalcoholic beverages was performed by microchip capillary electrophoresis with external contactless conductivity detection. An electrolyte solution consisting of 10.5 mM histidine, 50 mM acetic acid, and 2 mM 18-crown-6 at pH 4.1 was used for the determination of NH(4) (+), K(+), Ca(2+), Na(+), and Mg(2+). Fast analysis of Cl(-), NO(3) (-), and SO(4) (2-) was achieved in 20 mM 2-(N-morpholino)ethanesulfonic acid /histidine electrolyte solution at pH 6.0 and the simultaneous separation of up to 12 inorganic and organic anions was performed in a solution containing 10 mM His and 7 mM glutamic acid at pH 5.75. Limits of detection ranged from 90 to 250 mug/L for inorganic cations and anions, and from 200 to 2000 mug/L for organic anions and phosphate. Calibration curves showed linear dependencies over one to two orders of magnitude when the stacking effect was minimized by injecting standard solutions prepared in background electrolyte solutions. Total analysis times of 35 and 90 s were achieved for the determination of 5 inorganic cations and for the simultaneous determination of 12 inorganic and organic anions, respectively, which represents a considerable reduction of analysis time compared to conventional separation methods used in food analysis.
Collapse
Affiliation(s)
- Pavel Kubán
- Department of Chemistry, University of Basel, Spitalstrasse 51, 4004 Basel, Switzerland
| | | |
Collapse
|
32
|
Masár M, Wójcik L, Kaniansky D, Trojanowicz M. Zone electrophoresis separation of perfluorocarboxylic acids on a chip with conductivity detection. J Sep Sci 2005; 28:1271-7. [PMID: 16138678 DOI: 10.1002/jssc.200500187] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Perfluorinated carboxylic acids (PFCAs), amphiphiles of anthropogenic origin, are spread worldwide throughout the environment. This work deals with their zone electrophoresis (ZE) separation on a chip with coupled columns and integrated conductivity detection. Analogies with the electrophoretic behavior of PFCAs and fatty acids were employed in a search for electrolyte conditions suitable for their separation. ZE separations in the water-ethanol electrolyte systems, based on differences in the ionic mobilities of the anions of PFCAs, provided favorable resolution and detection conditions of the homologues containing up to 10 carbon atoms in the alkyl chain. Concentration limits of detection of 0.3-6.5 micromol/L were attained for PFCAs (loaded by a 900 nL volume sample injection channel of the chip) under these separation conditions. The material of which the chip was made [poly(methylmethacrylate)] restricted its use in investigations of the separations of higher PFCA homologues as it was damaged by ethanolic and/or methanolic background electrolyte solutions required in experiments with these amphiphilic compounds.
Collapse
Affiliation(s)
- Marián Masár
- Department of Analytical Chemistry, Faculty of Natural Sciences, Comenius University, Bratislava, Slovakia
| | | | | | | |
Collapse
|
33
|
Masár M, Poliaková K, Danková M, Kaniansky D, Stanislawski B. Determination of organic acids in wine by zone electrophoresis on a chip with conductivity detection. J Sep Sci 2005; 28:905-14. [PMID: 16013816 DOI: 10.1002/jssc.200500061] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
An appropriate combination of separation mechanisms (simultaneous use of differences in pK values, host-guest complexations, and the ionic strength dependences of the actual ionic mobilities) provided zone electrophoresis (ZE) resolution of 22 organic and inorganic acids expected in wines on a polymethylmethacrylate (PMMA) chip with integrated conductivity detection. These separating conditions offered a framework for the ZE determination of organic acids responsible for some important organoleptic characteristics of wines (tartrate, malate, succinate, acetate, citrate, and lactate). The ZE procedure developed in this context is simple and rapid (ca. 10 minutes' analysis time), while affording reproducible migration and quantitation data for the acids. For example, 0.8-2.0% RSD values characterized the migration times of the acids for 25 repeated ZE runs with the same sample carried out in 5 days in the background electrolyte solution prepared freshly on a daily basis, while 3-5% RSD values were typical for the accompanying peak area data. The concentration ranges within which the acids of analytical interest could be determined in one ZE run covered all wine samples included in our study (100-400-fold sample dilutions were needed to work under the conditions corresponding to the validities of the calibration data). 90-110% recoveries of the acids as obtained repeatedly for one of the reference wine samples used in our experiments indicate a good predisposition of the present method to provide accurate analytical results. This statement also supports the results from the determination of the acids in reference wine samples with claimed concentrations of malic (five samples), tartaric (one sample), and lactic (one sample) acids.
Collapse
Affiliation(s)
- Marián Masár
- Department of Analytical Chemistry, Faculty of Natural Sciences, Comenius University, Mlynská Dolina CH-2, SK-84215 Bratislava, Slovakia
| | | | | | | | | |
Collapse
|