1
|
Xie Y, Dai L, Yang Y. Microfluidic technology and its application in the point-of-care testing field. BIOSENSORS & BIOELECTRONICS: X 2022; 10:100109. [PMID: 35075447 PMCID: PMC8769924 DOI: 10.1016/j.biosx.2022.100109] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2021] [Revised: 01/06/2022] [Accepted: 01/09/2022] [Indexed: 05/15/2023]
Abstract
Since the outbreak of the coronavirus disease 2019 (COVID-19), countries around the world have suffered heavy losses of life and property. The global pandemic poses a challenge to the global public health system, and public health organizations around the world are actively looking for ways to quickly and efficiently screen for viruses. Point-of-care testing (POCT), as a fast, portable, and instant detection method, is of great significance in infectious disease detection, disease screening, pre-disease prevention, postoperative treatment, and other fields. Microfluidic technology is a comprehensive technology that involves various interdisciplinary disciplines. It is also known as a lab-on-a-chip (LOC), and can concentrate biological and chemical experiments in traditional laboratories on a chip of several square centimeters with high integration. Therefore, microfluidic devices have become the primary implementation platform of POCT technology. POCT devices based on microfluidic technology combine the advantages of both POCT and microfluids, and are expected to shine in the biomedical field. This review introduces microfluidic technology and its applications in combination with other technologies.
Collapse
Affiliation(s)
- Yaping Xie
- Sansure Biotech Inc., Changsha, 410205, PR China
- School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, PR China
| | - Lizhong Dai
- Sansure Biotech Inc., Changsha, 410205, PR China
| | - Yijia Yang
- Sansure Biotech Inc., Changsha, 410205, PR China
| |
Collapse
|
2
|
Interfacing microfluidics with information-rich detection systems for cells, bioparticles, and molecules. Anal Bioanal Chem 2022; 414:4575-4589. [PMID: 35389095 PMCID: PMC8987515 DOI: 10.1007/s00216-022-04043-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 03/01/2022] [Accepted: 03/24/2022] [Indexed: 11/16/2022]
Abstract
The development of elegant and numerous microfluidic manipulations has enabled significant advances in the processing of small volume samples and the detection of minute amounts of biomaterials. Effective isolation of single cells in a defined volume as well as manipulations of complex bioparticle or biomolecule mixtures allows for the utilization of information-rich detection methods including mass spectrometry, electron microscopy imaging, and amplification/sequencing. The art and science of translating biosamples from microfluidic platforms to highly advanced, information-rich detection system is the focus of this review, where we term the translation between the microfluidics elements to the external world “off-chipping.” When presented with the challenge of presenting sub-nanoliter volumes of manipulated sample to a detection scheme, several delivery techniques have been developed for effective analysis. These techniques include spraying (electrospray, nano-electrospray, pneumatic), meniscus-defined volumes (droplets, plugs), constrained volumes (narrow channels, containers), and phase changes (deposition, freezing). Each technique has been proven effective in delivering highly defined samples from microfluidic systems to the detection elements. This review organizes and presents selective publications that illustrate the advancements of these delivery techniques with respect to the type of sample analyzed, while introducing each strategy and providing historical perspective. The publications highlighted in this review were chosen due to their significance and relevance in the development of their respective off-chip technique.
Collapse
|
3
|
Saraf N, Villegas M, Willenberg BJ, Seal S. Multiplex Viral Detection Platform Based on a Aptamers-Integrated Microfluidic Channel. ACS OMEGA 2019; 4:2234-2240. [PMID: 30729227 PMCID: PMC6358057 DOI: 10.1021/acsomega.8b03277] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Accepted: 01/11/2019] [Indexed: 05/02/2023]
Abstract
A polydimethylsiloxane-based microfluidic device has been developed for the multiplex detection of viral envelope proteins such as Zika and chikungunya on a single platform using aptamer-analyte interactions. The channel is integrated with microsized pillars that increase the surface area allowing more aptamers to attach to the incoming envelope protein molecules, thus increasing the overall sensitivity of the system. The working of the device depends on the formation of protein-mediated sandwich morphology that is obtained using an aptamer and aptamer-functionalized gold nanoparticle (AuNP) pair. The colorimetric signal is obtained upon introduction of silver reagents into the channel, which are selectively deposited on the AuNP surface, providing a gray contrast in the testing zone. The microfluidic channel approach successfully detected clinically relevant concentrations of Zika and chikungunya envelope proteins in phosphine-buffered saline (1 pM) and calf blood (100 pM) with high specificity using gold-decorated aptamers integrated in a microfluidic channel.
Collapse
Affiliation(s)
- Nileshi Saraf
- Advanced
Materials Processing and Analysis Centre, Department of
Materials Science and Engineering, Department of Internal Medicine, College of
Medicine, and Nanoscience Technology Centre, University
of Central Florida, Orlando, Florida 32827, United States
| | - Michael Villegas
- University
of Florida, Gainesville, Florida 32611, United
States
| | - Bradley Jay Willenberg
- Advanced
Materials Processing and Analysis Centre, Department of
Materials Science and Engineering, Department of Internal Medicine, College of
Medicine, and Nanoscience Technology Centre, University
of Central Florida, Orlando, Florida 32827, United States
| | - Sudipta Seal
- Advanced
Materials Processing and Analysis Centre, Department of
Materials Science and Engineering, Department of Internal Medicine, College of
Medicine, and Nanoscience Technology Centre, University
of Central Florida, Orlando, Florida 32827, United States
| |
Collapse
|
4
|
Tähkä SM, Bonabi A, Jokinen VP, Sikanen TM. Aqueous and non-aqueous microchip electrophoresis with on-chip electrospray ionization mass spectrometry on replica-molded thiol-ene microfluidic devices. J Chromatogr A 2017; 1496:150-156. [PMID: 28347516 DOI: 10.1016/j.chroma.2017.03.018] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2017] [Revised: 03/03/2017] [Accepted: 03/10/2017] [Indexed: 12/25/2022]
Abstract
This work describes aqueous and non-aqueous capillary electrophoresis on thiol-ene-based microfluidic separation devices that feature fully integrated and sharp electrospray ionization (ESI) emitters. The chip fabrication is based on simple and low-cost replica-molding of thiol-ene polymers under standard laboratory conditions. The mechanical rigidity and the stability of the materials against organic solvents, acids and bases could be tuned by adjusting the respective stoichiometric ratio of the thiol and allyl ("ene") monomers, which allowed us to carry out electrophoresis separation in both aqueous and non-aqueous (methanol- and ethanol-based) background electrolytes. The stability of the ESI signal was generally ≤10% RSD for all emitters. The respective migration time repeatabilities in aqueous and non-aqueous background electrolytes were below 3 and 14% RSD (n=4-6, with internal standard). The analytical performance of the developed thiol-ene microdevices was shown in mass spectrometry (MS) based analysis of peptides, proteins, and small molecules. The theoretical plate numbers were the highest (1.2-2.4×104m-1) in ethanol-based background electrolytes. The ionization efficiency also increased under non-aqueous conditions compared to aqueous background electrolytes. The results show that replica-molding of thiol-enes is a feasible approach for producing ESI microdevices that perform in a stable manner in both aqueous and non-aqueous electrophoresis.
Collapse
Affiliation(s)
- Sari M Tähkä
- Faculty of Pharmacy, Drug Research Programme, Viikinkaari 5E, FI-00014, University of Helsinki, Helsinki, Finland.
| | - Ashkan Bonabi
- Faculty of Pharmacy, Drug Research Programme, Viikinkaari 5E, FI-00014, University of Helsinki, Helsinki, Finland.
| | - Ville P Jokinen
- Department of Materials Science and Engineering, School of Chemical Technology, Aalto University, Tietotie 3, FI-00076 Aalto, Espoo, Finland.
| | - Tiina M Sikanen
- Faculty of Pharmacy, Drug Research Programme, Viikinkaari 5E, FI-00014, University of Helsinki, Helsinki, Finland.
| |
Collapse
|
5
|
Guler AT, Waaijer CJ, Mohammed Y, Palmblad M. Automating bibliometric analyses using Taverna scientific workflows: A tutorial on integrating Web Services. J Informetr 2016. [DOI: 10.1016/j.joi.2016.05.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
6
|
Feng X, Liu BF, Li J, Liu X. Advances in coupling microfluidic chips to mass spectrometry. MASS SPECTROMETRY REVIEWS 2015; 34:535-57. [PMID: 24399782 DOI: 10.1002/mas.21417] [Citation(s) in RCA: 87] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2013] [Revised: 11/07/2013] [Accepted: 11/07/2013] [Indexed: 05/26/2023]
Abstract
Microfluidic technology has shown advantages of low sample consumption, reduced analysis time, high throughput, and potential for integration and automation. Coupling microfluidic chips to mass spectrometry (Chip-MS) can greatly improve the overall analytical performance of MS-based approaches and expand their potential applications. In this article, we review the advances of Chip-MS in the past decade, covering innovations in microchip fabrication, microchips coupled to electrospray ionization (ESI)-MS and matrix-assisted laser desorption/ionization (MALDI)-MS. Development of integrated microfluidic systems for automated MS analysis will be further documented, as well as recent applications of Chip-MS in proteomics, metabolomics, cell analysis, and clinical diagnosis.
Collapse
MESH Headings
- Animals
- Chromatography, Liquid/instrumentation
- Chromatography, Liquid/methods
- Electrophoresis, Microchip/instrumentation
- Electrophoresis, Microchip/methods
- Equipment Design
- Humans
- Lab-On-A-Chip Devices
- Lipids/analysis
- Metabolomics/instrumentation
- Metabolomics/methods
- Polysaccharides/analysis
- Proteins/analysis
- Proteomics/instrumentation
- Proteomics/methods
- Spectrometry, Mass, Electrospray Ionization/instrumentation
- Spectrometry, Mass, Electrospray Ionization/methods
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/instrumentation
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods
Collapse
Affiliation(s)
- Xiaojun Feng
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Bi-Feng Liu
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Jianjun Li
- Human Health Therapeutics, National Research Council Canada, Ottawa, Ontario, Canada K1A 0R6
| | - Xin Liu
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| |
Collapse
|
7
|
Arscott S. SU-8 as a material for lab-on-a-chip-based mass spectrometry. LAB ON A CHIP 2014; 14:3668-3689. [PMID: 25029537 DOI: 10.1039/c4lc00617h] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
This short review focuses on the application of SU-8 for the microchip-based approach to the miniaturization of mass spectrometry. Chip-based mass spectrometry will make the technology commonplace and bring benefits such as lower costs and autonomy. The chip-based miniaturization of mass spectrometry necessitates the use of new materials which are compatible with top-down fabrication involving both planar and non-planar processes. In this context, SU-8 is a very versatile epoxy-based, negative tone resist which is sensitive to ultraviolet radiation, X-rays and electron beam exposure. It has a very wide thickness range, from nanometres to millimetres, enabling the formation of mechanically rigid, very high aspect ratio, vertical, narrow width structures required to form microfluidic slots and channels for laboratory-on-a-chip design. It is also relatively chemically resistant and biologically compatible in terms of the liquid solutions used for mass spectrometry. This review looks at the impact and potential of SU-8 on the different parts of chip-based mass spectrometry - pre-treatment, ionization processes, and ion sorting and detection.
Collapse
Affiliation(s)
- Steve Arscott
- Institut d'Electronique, de Microélectronique et de Nanotechnologie (IEMN), CNRS UMR8520, The University of Lille, Cité Scientifique, Avenue Poincaré, 59652 Villeneuve d'Ascq, France.
| |
Collapse
|
8
|
Recent developments in microfluidic chip-based separation devices coupled to MS for bioanalysis. Bioanalysis 2013; 5:2567-80. [DOI: 10.4155/bio.13.196] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
In recent years, the development of microfluidic chip separation devices coupled to MS has dramatically increased for high-throughput bioanalysis. In this review, advances in different types of microfluidic chip separation devices, such as electrophoresis- and LC-based microchips, as well as 2D design of microfluidic chip-based separation devices will be discussed. In addition, the utilization of chip-based separation devices coupled to MS for analyzing peptides/proteins, glycans, drug metabolites and biomarkers for various bioanalytical applications will be evaluated.
Collapse
|
9
|
Lin SL, Bai HY, Lin TY, Fuh MR. Microfluidic chip-based liquid chromatography coupled to mass spectrometry for determination of small molecules in bioanalytical applications. Electrophoresis 2012; 33:635-43. [PMID: 22451056 DOI: 10.1002/elps.201100380] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
The development and integration of microfabricated liquid chromatography (LC) microchips have increased dramatically in the last decade due to the needs of enhanced sensitivity and rapid analysis as well as the rising concern on reducing environmental impacts of chemicals used in various types of chemical and biochemical analyses. Recent development of microfluidic chip-based LC mass spectrometry (chip-based LC-MS) has played an important role in proteomic research for high throughput analysis. To date, the use of chip-based LC-MS for determination of small molecules, such as biomarkers, active pharmaceutical ingredients (APIs), and drugs of abuse and their metabolites, in clinical and pharmaceutical applications has not been thoroughly investigated. This mini-review summarizes the utilization of commercial chip-based LC-MS systems for determination of small molecules in bioanalytical applications, including drug metabolites and disease/tumor-associated biomarkers in clinical samples as well as adsorption, distribution, metabolism, and excretion studies of APIs in drug discovery and development. The different types of commercial chip-based interfaces for LC-MS analysis are discussed first and followed by applications of chip-based LC-MS on biological samples as well as the comparison with other LC-MS techniques.
Collapse
Affiliation(s)
- Shu-Ling Lin
- Department of Chemistry, Soochow University, Taipei, Taiwan
| | | | | | | |
Collapse
|
10
|
Microchip capillary electrophoresis–electrospray ionization–mass spectrometry of intact proteins using uncoated Ormocomp microchips. Anal Chim Acta 2012; 711:69-76. [DOI: 10.1016/j.aca.2011.10.059] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2011] [Revised: 10/25/2011] [Accepted: 10/29/2011] [Indexed: 01/30/2023]
|
11
|
Reschke BR, Timperman AT. A study of electrospray ionization emitters with differing geometries with respect to flow rate and electrospray voltage. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2011; 22:2115-2124. [PMID: 21989703 DOI: 10.1007/s13361-011-0251-4] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2011] [Revised: 09/10/2011] [Accepted: 09/13/2011] [Indexed: 05/31/2023]
Abstract
The performance of several electrospray ionization emitters with different orifice inside diameters (i.d.s), geometries, and materials are compared. The sample solution is delivered by pressure driven flow, and the electrospray ionization voltage and flow rate are varied systematically for each emitter investigated, while the signal intensity of a standard is measured. The emitters investigated include a series of emitters with a tapered outside diameters (o.d.) and unaltered i.d.s, a series of emitters with tapered o.d.s and i.d.s, an emitter with a monolithic frit and a tapered o.d., and an emitter fabricated from polypropylene. The results show that for the externally etched emitters, signal was nearly independent of i.d. and better ion utilization was achieved at lower flow rates. Furthermore, emitters with a 50 μm i.d. and an etched o.d. produced about 1.5 times more signal than etched emitters with smaller i.d.s and about 3.5 times more signal than emitters with tapered inner and outer dimensions. Additionally, the work presented here has important implications for applications in which maximizing signal intensity and reducing frictional resistance to flow are necessary. Overall, the work provides an initial assessment of the critical parameters that contribute to maximizing the signal for electrospray ionization sources interfaced with pressure driven flows.
Collapse
Affiliation(s)
- Brent R Reschke
- C. Eugene Bennet Department of Chemistry, West Virginia University, Morgantown, WV 26506, USA
| | | |
Collapse
|
12
|
Shang F, Guihen E, Glennon JD. Recent advances in miniaturisation - The role of microchip electrophoresis in clinical analysis. Electrophoresis 2011; 33:105-16. [DOI: 10.1002/elps.201100454] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2011] [Revised: 10/12/2011] [Accepted: 10/13/2011] [Indexed: 01/27/2023]
|
13
|
Sun X, Kelly RT, Tang K, Smith RD. Membrane-based emitter for coupling microfluidics with ultrasensitive nanoelectrospray ionization-mass spectrometry. Anal Chem 2011; 83:5797-803. [PMID: 21657269 PMCID: PMC3139426 DOI: 10.1021/ac200960h] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
An integrated poly(dimethylsiloxane) (PDMS) membrane-based microfluidic emitter for high-performance nanoelectrospray ionization mass spectrometry has been fabricated and evaluated. The ∼100-μm-thick emitter was created by cutting a PDMS membrane that protrudes beyond the bulk substrate. The reduced surface area at the emitter enhances the electric field and reduces wetting of the surface by the electrospray solvent. As such, the emitter enables highly stable electrosprays at flow rates as low as 10 nL/min and is compatible with electrospray solvents containing a large organic component (e.g., 90% methanol). This approach enables facile emitter construction and provides excellent stability, reproducibility, and sensitivity as well as compatibility with multilayer soft lithography.
Collapse
Affiliation(s)
- Xuefei Sun
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352
| | - Ryan T. Kelly
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352
| | - Keqi Tang
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352
| | - Richard D. Smith
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352
| |
Collapse
|
14
|
Kitagawa F, Otsuka K. Recent progress in microchip electrophoresis-mass spectrometry. J Pharm Biomed Anal 2010; 55:668-78. [PMID: 21130595 DOI: 10.1016/j.jpba.2010.11.013] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2010] [Revised: 11/10/2010] [Accepted: 11/10/2010] [Indexed: 01/30/2023]
Abstract
This review highlights the methodological and instrumental developments in microchip electrophoresis (MCE)-mass spectrometry (MS) from 1997. In MCE-MS, the development of ionization interface is one of the most important issues to realize highly sensitive detection and high separation efficiency. Among several interfaces, electrospray ionization (ESI) has been mainly employed to MCE-MS since a simple structure of the ESI interface is suitable for coupling with the microchips. Although the number of publications is still limited, laser desorption ionization (LDI) interface has also been developed for MCE-MS. The characteristics of the ESI and LDI interfaces applied to the electrophoresis microchips are presented in this review. The scope of applications in MCE-MS covers mainly biogenic compounds such as bioactive amines, peptides, tryptic digests and proteins. This review provides a comprehensive table listing the applications in MCE-MS.
Collapse
Affiliation(s)
- Fumihiko Kitagawa
- Department of Material Chemistry, Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto 615-8510, Japan.
| | | |
Collapse
|
15
|
Hoek I, Tho F, Arnold WM. Sodium hydroxide treatment of PDMS based microfluidic devices. LAB ON A CHIP 2010; 10:2283-5. [PMID: 20607182 DOI: 10.1039/c004769d] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
We discuss the use of aqueous NaOH as a facile surface treatment method to control the electroosmotic flow in PDMS microchannels. Flushing of PDMS/PDMS and glass/PDMS microchannels with 1 M NaOH for 24 h leads to a doubling of the electroosmotic flow. This high flow rate is comparable to the flow rates achieved by treating PDMS microchannels with O2 plasma. Contact angle measurements and ATR-FTIR analysis show that the surface chemistry of the NaOH treated PDMS differs from O2 plasma treated PDMS. An important advantage of the NaOH treated surfaces is the enhanced stability, irrespective of whether the devices are stored in air or water.
Collapse
Affiliation(s)
- Ingrid Hoek
- Industrial Research Ltd., 69 Gracefield Road, Lower Hutt, 5040, New Zealand.
| | | | | |
Collapse
|
16
|
Sikanen T, Franssila S, Kauppila TJ, Kostiainen R, Kotiaho T, Ketola RA. Microchip technology in mass spectrometry. MASS SPECTROMETRY REVIEWS 2010; 29:351-391. [PMID: 19514079 DOI: 10.1002/mas.20238] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Microfabrication of analytical devices is currently of growing interest and many microfabricated instruments have also entered the field of mass spectrometry (MS). Various (atmospheric pressure) ion sources as well as mass analyzers have been developed exploiting microfabrication techniques. The most common approach thus far has been the miniaturization of the electrospray ion source and its integration with various separation and sampling units. Other ionization techniques, mainly atmospheric pressure chemical ionization and photoionization, have also been subject to miniaturization, though they have not attracted as much attention. Likewise, all common types of mass analyzers have been realized by microfabrication and, in most cases, successfully applied to MS analysis in conjunction with on-chip ionization. This review summarizes the latest achievements in the field of microfabricated ion sources and mass analyzers. Representative applications are reviewed focusing on the development of fully microfabricated systems where ion sources or analyzers are integrated with microfluidic separation devices or microfabricated pums and detectors, respectively. Also the main microfabrication methods, with their possibilities and constraints, are briefly discussed together with the most commonly used materials.
Collapse
Affiliation(s)
- Tiina Sikanen
- Faculty of Pharmacy, Division of Pharmaceutical Chemistry, University of Helsinki, Helsinki, Finland.
| | | | | | | | | | | |
Collapse
|
17
|
Zhou J, Ellis AV, Voelcker NH. Recent developments in PDMS surface modification for microfluidic devices. Electrophoresis 2010; 31:2-16. [DOI: 10.1002/elps.200900475] [Citation(s) in RCA: 599] [Impact Index Per Article: 39.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
18
|
|
19
|
Mellors JS, Gorbounov V, Ramsey RS, Ramsey JM. Fully integrated glass microfluidic device for performing high-efficiency capillary electrophoresis and electrospray ionization mass spectrometry. Anal Chem 2008; 80:6881-7. [PMID: 18698800 PMCID: PMC3125599 DOI: 10.1021/ac800428w] [Citation(s) in RCA: 148] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
A microfabricated device has been developed in which electrospray ionization is performed directly from the corner of a rectangular glass microchip. The device allows highly efficient electrokinetically driven separations to be coupled directly to a mass spectrometer (MS) without the use of external pressure sources or the insertion of capillary spray tips. An electrokinetic-based hydraulic pump is integrated on the chip that directs eluting materials to the monolithically integrated spray tip. A positively charged surface coating, PolyE-323, is used to prevent surface interactions with peptides and proteins and to reverse the electroosmotic flow in the separation channel. The device has been used to perform microchip CE-MS analysis of peptides and proteins with efficiencies over 200,000 theoretical plates (1,000,000 plates/m). The sensitivity and stability of the microfabricated ESI source were found to be comparable to that of commercial pulled fused-silica capillary nanospray sources.
Collapse
Affiliation(s)
- J. S. Mellors
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapman Hall, Room 251, Chapel Hill, North Carolina 27599-3216
| | - V. Gorbounov
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapman Hall, Room 251, Chapel Hill, North Carolina 27599-3216
| | - R. S. Ramsey
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapman Hall, Room 251, Chapel Hill, North Carolina 27599-3216
| | - J. M. Ramsey
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapman Hall, Room 251, Chapel Hill, North Carolina 27599-3216
| |
Collapse
|
20
|
Malsche WD, Gardeniers H, Desmet G. Experimental Study of Porous Silicon Shell Pillars under Retentive Conditions. Anal Chem 2008; 80:5391-400. [DOI: 10.1021/ac800424q] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Wim De Malsche
- Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium, and Research Programme Mesofluidics, MESA+ Institute for Nanotechnology, MESA+ Research Institute, Enschede, The Netherlands
| | - Han Gardeniers
- Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium, and Research Programme Mesofluidics, MESA+ Institute for Nanotechnology, MESA+ Research Institute, Enschede, The Netherlands
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium, and Research Programme Mesofluidics, MESA+ Institute for Nanotechnology, MESA+ Research Institute, Enschede, The Netherlands
| |
Collapse
|
21
|
Kelly RT, Tang K, Irimia D, Toner M, Smith RD. Elastomeric microchip electrospray emitter for stable cone-jet mode operation in the nanoflow regime. Anal Chem 2008; 80:3824-31. [PMID: 18419138 PMCID: PMC2692495 DOI: 10.1021/ac8000786] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Despite widespread interest in combining laboratory-on-a-chip technologies with mass spectrometry (MS)-based analyses, the coupling of microfluidics to electrospray ionization (ESI)-MS remains challenging. We report a robust, integrated poly(dimethylsiloxane) microchip interface for ESI-MS using simple and widely accessible microfabrication procedures. The interface uses an auxiliary channel to provide electrical contact for the stable cone-jet electrospray without sample loss or dilution. The electric field at the channel terminus is enhanced by two vertical cuts that cause the interface to taper to a line rather than to a point, and the formation of a small Taylor cone at the channel exit ensures subnanoliter postcolumn dead volumes. Cone-jet mode electrospray was demonstrated for up to 90% aqueous solutions and for extended durations. Comparable ESI-MS sensitivities were achieved using both microchip and conventional fused silica capillary emitters, but stable cone-jet mode electrosprays could be established over a far broader range of flow rates (from 50-1000 nL/min) and applied potentials using the microchip emitters. This attribute of the microchip emitter should simplify electrospray optimization and make the stable electrospray more resistant to external perturbations.
Collapse
Affiliation(s)
- Ryan T Kelly
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, USA
| | | | | | | | | |
Collapse
|
22
|
Gaspar A, Englmann M, Fekete A, Harir M, Schmitt-Kopplin P. Trends in CE-MS 2005–2006. Electrophoresis 2008; 29:66-79. [DOI: 10.1002/elps.200700721] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
23
|
Sikanen T, Tuomikoski S, Ketola RA, Kostiainen R, Franssila S, Kotiaho T. Fully Microfabricated and Integrated SU-8-Based Capillary Electrophoresis-Electrospray Ionization Microchips for Mass Spectrometry. Anal Chem 2007; 79:9135-44. [DOI: 10.1021/ac071531+] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
24
|
Koster S, Verpoorte E. A decade of microfluidic analysis coupled with electrospray mass spectrometry: an overview. LAB ON A CHIP 2007; 7:1394-1412. [PMID: 17960264 DOI: 10.1039/b709706a] [Citation(s) in RCA: 114] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
This review presents a thorough overview covering the period 1997-2006 of microfluidic chips coupled to mass spectrometry through an electrospray interface. The different types of fabrication processes and materials used to fabricate these chips throughout this period are discussed. Three 'eras' of interfaces are clearly distinguished. The earliest approach involves spraying from the edge of a chip, while later devices either incorporate a standard fused-silica emitter inserted into the device or fully integrated emitters formed during chip fabrication. A summary of microfluidic-electrospray devices for performing separations and sample pretreatment steps before sample introduction into the mass spectrometer is also presented.
Collapse
Affiliation(s)
- Sander Koster
- Groningen Research Institute of Pharmacy, University of Groningen, Antonius Deusinglaan 1, 9713AV Groningen, The Netherlands.
| | | |
Collapse
|
25
|
Hoffmann P, Häusig U, Schulze P, Belder D. Microfluidic glass chips with an integrated nanospray emitter for coupling to a mass spectrometer. Angew Chem Int Ed Engl 2007; 46:4913-6. [PMID: 17516595 DOI: 10.1002/anie.200605152] [Citation(s) in RCA: 94] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Peter Hoffmann
- Institut für Analytische Chemie, Chemo- und Biosensorik, Universität Regensburg, 93040 Regensburg, Germany
| | | | | | | |
Collapse
|
26
|
Hoffmann P, Häusig U, Schulze P, Belder D. Mikrofluidische Glas-Chips mit integriertem Nanospray-Emitter zur Kopplung mit der Massenspektrometrie. Angew Chem Int Ed Engl 2007. [DOI: 10.1002/ange.200605152] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
27
|
Affiliation(s)
- R K Gilpin
- Brehm Research Laboratory, University Park, Wright State University, Fairborn, Ohio 45324-2031, USA
| | | |
Collapse
|
28
|
Zamfir AD. Recent advances in sheathless interfacing of capillary electrophoresis and electrospray ionization mass spectrometry. J Chromatogr A 2007; 1159:2-13. [PMID: 17428492 DOI: 10.1016/j.chroma.2007.03.115] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2006] [Revised: 03/20/2007] [Accepted: 03/29/2007] [Indexed: 01/13/2023]
Abstract
On line sheathless capillary electrophoresis (CE)-electrospray ionization (ESI) mass spectrometry is developing as a powerful method in bioanalytics as it provides high resolution, sensitivity, relatively short analysis times, and amenability to a wide class of compounds. However, unlike the popular nano liquid chromatography (nano LC) or sheath-flow CE/ESI-MS, the sheathless coupling lacks standardized designs and protocols. For this reason, sheathless CE/ESI is a subject of conceptual and technical upgrading more than any other liquid-based separation method hyphenated to MS. Here, recent innovations in sheathless CE/ESI-MS interfacing are gathered in a survey covering the 2005/2006 period. In the first part of the review, the current concepts and methods for in-laboratory production of sturdy designs based on either conductive emitters or electrodeless interfaces are described. The second part is dedicated to microchip CE platforms with externally connected emitters for sheathless coupling to ESI-MS and advanced microfluidic devices integrating CE and sheathless electrospray in a single chip substrate. The advantages, limitations and feasibility for certain applications of all these systems as well as the perspectives for their performance improvement are concurrently assessed.
Collapse
Affiliation(s)
- Alina D Zamfir
- Department of Chemistry and Biology, University of Arad, Revolutiei Blvd. 1, RO-310139 Arad, Romania.
| |
Collapse
|
29
|
Klampfl CW, Buchberger W. Coupling of capillary electroseparation techniques with mass spectrometric detection. Anal Bioanal Chem 2007; 388:533-6. [PMID: 17351706 DOI: 10.1007/s00216-007-1221-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2006] [Revised: 02/13/2007] [Accepted: 02/16/2007] [Indexed: 10/23/2022]
Affiliation(s)
- Christian W Klampfl
- Institute of Analytical Chemistry, Johannes Kepler University Linz, Altenberger Str. 69, 4040, Linz, Austria.
| | | |
Collapse
|
30
|
Abstract
Recent advances of microfluidics systems suitable for multiplexed MS analysis are reviewed with respect to fabrication technologies and applications.
Collapse
|
31
|
Nordhoff E, Lehrach H. Identification and characterization of DNA-binding proteins by mass spectrometry. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2006; 104:111-95. [PMID: 17290821 DOI: 10.1007/10_2006_037] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Mass spectrometry is the most sensitive and specific analytical technique available for protein identification and quantification. Over the past 10 years, by the use of mass spectrometric techniques hundreds of previously unknown proteins have been identified as DNA-binding proteins that are involved in the regulation of gene expression, replication, or DNA repair. Beyond this task, the applications of mass spectrometry cover all aspects from sequence and modification analysis to protein structure, dynamics, and interactions. In particular, two new, complementary ionization techniques have made this possible: matrix-assisted laser desorption/ionization and electrospray ionization. Their combination with different mass-over-charge analyzers and ion fragmentation techniques, as well as specific enzymatic or chemical reactions and other analytical techniques, has led to the development of a broad repertoire of mass spectrometric methods that are now available for the identification and detailed characterization of DNA-binding proteins. These techniques, how they work, what their requirements and limitations are, and selected examples that document their performance are described and discussed in this chapter.
Collapse
Affiliation(s)
- Eckhard Nordhoff
- Department Lehrach, Max Planck Institute for Molecular Genetics, Ihnestrasse 73, 14195 Berlin, Germany.
| | | |
Collapse
|
32
|
Hernández-Borges J, Borges-Miquel TM, Rodríguez-Delgado MA, Cifuentes A. Sample treatments prior to capillary electrophoresis-mass spectrometry. J Chromatogr A 2006; 1153:214-26. [PMID: 17098242 DOI: 10.1016/j.chroma.2006.10.070] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2006] [Revised: 10/13/2006] [Accepted: 10/30/2006] [Indexed: 10/23/2022]
Abstract
Sample preparation is a crucial part of chemical analysis and in most cases can become the bottleneck of the whole analytical process. Its adequacy is a key factor in determining the success of the analysis and, therefore, careful selection and optimization of the parameters controlling sample treatment should be carried out. This work revises the different strategies that have been developed for sample preparation prior to capillary electrophoresis-mass spectrometry (CE-MS). Namely the present work presents an exhaustive and critical revision of the different samples treatments used together with on-line CE-MS including works published from January 2000 to July 2006.
Collapse
Affiliation(s)
- Javier Hernández-Borges
- Department of Analytical Chemistry, Nutrition and Food Science, University of La Laguna, Avda. Astrofísico Fco. Sánchez s/n, 38071 La Laguna, Tenerife, Spain.
| | | | | | | |
Collapse
|
33
|
Edgar JS, Pabbati CP, Lorenz RM, He M, Fiorini GS, Chiu DT. Capillary electrophoresis separation in the presence of an immiscible boundary for droplet analysis. Anal Chem 2006; 78:6948-54. [PMID: 17007519 PMCID: PMC2525566 DOI: 10.1021/ac0613131] [Citation(s) in RCA: 68] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
This paper demonstrates the ability to use capillary electrophoresis (CE) separation coupled with laser-induced fluorescence for analyzing the contents of single femtoliter-volume aqueous droplets. A single droplet was formed using a T-channel (3 microm wide by 3 microm tall) connected to microinjectors, and then the droplet was fluidically moved to an immiscible boundary that isolates the CE channel (50 microm wide by 50 microm tall) from the droplet generation region. Fusion of the aqueous droplet with the immiscible boundary effectively injects the droplet content into the separation channel. In addition to injecting the contents of droplets, we found aqueous samples can be introduced directly into the separation channel by reversibly penetrating and resealing the immiscible partition. Because droplet generation in channels requires hydrophobic surfaces, we have also investigated the advantages to using all hydrophobic channels versus channel systems with patterned hydrophobic and hydrophilic regions. To fabricate devices with patterned surface chemistry, we have developed a simple strategy based on differential wetting to deposit selectively a hydrophilic polymer (poly(styrenesulfonate)) onto desired regions of the microfluidic chip. Finally, we applied our device to the separation of a simple mixture of fluorescein-labeled amino acids contained within a approximately 10-fL droplet.
Collapse
Affiliation(s)
- J. Scott Edgar
- Department of Chemistry University of Washington Seattle, WA 98195−1700
| | | | - Robert M. Lorenz
- Department of Chemistry University of Washington Seattle, WA 98195−1700
| | - Mingyan He
- Department of Chemistry University of Washington Seattle, WA 98195−1700
| | - Gina S. Fiorini
- Department of Chemistry University of Washington Seattle, WA 98195−1700
| | - Daniel T. Chiu
- Department of Chemistry University of Washington Seattle, WA 98195−1700
| |
Collapse
|
34
|
Lorenz RM, Edgar JS, Jeffries GDM, Chiu DT. Microfluidic and Optical Systems for the On-Demand Generation and Manipulation of Single Femtoliter-Volume Aqueous Droplets. Anal Chem 2006; 78:6433-9. [PMID: 16970318 DOI: 10.1021/ac060748l] [Citation(s) in RCA: 104] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
This paper describes a fluidic and optical platform for the generation and manipulation of single femtoliter-volume aqueous droplets. Individual droplets were generated on-demand using a microfluidic chamber that confers environmental flow stability. Optical vortex traps were implemented to manipulate and transport the generated droplets, which have a lower refractive index than the immiscible medium in which the droplets are immersed and thus cannot be trapped using conventional optical tweezers. We also demonstrated the ability to shrink and increase the refractive index of the generated droplet, thereby permitting its facile fusion with another droplet using an optical tweezer. To illustrate the versatility of this platform, we have performed both fast (<1 s) and slow (>1 h) chemical reactions in these femtoliter-volume aqueous droplets.
Collapse
Affiliation(s)
- Robert M Lorenz
- Department of Chemistry, University of Washington, Seattle, Washington 98195-1700, USA
| | | | | | | |
Collapse
|
35
|
Dittrich PS, Tachikawa K, Manz A. Micro Total Analysis Systems. Latest Advancements and Trends. Anal Chem 2006; 78:3887-908. [PMID: 16771530 DOI: 10.1021/ac0605602] [Citation(s) in RCA: 564] [Impact Index Per Article: 29.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Petra S Dittrich
- Institute for Analytical Sciences, Bunsen-Kirchhoff-Strasse 11, D-44139 Dortmund, Germany
| | | | | |
Collapse
|