1
|
de Koster N, Clark CP, Kohler I. Past, present, and future developments in enantioselective analysis using capillary electromigration techniques. Electrophoresis 2021; 42:38-57. [PMID: 32914880 PMCID: PMC7821218 DOI: 10.1002/elps.202000151] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2020] [Revised: 08/22/2020] [Accepted: 09/08/2020] [Indexed: 12/16/2022]
Abstract
Enantioseparation of chiral products has become increasingly important in a large diversity of academic and industrial applications. The separation of chiral compounds is inherently challenging and thus requires a suitable analytical technique that can achieve high resolution and sensitivity. In this context, CE has shown remarkable results so far. Chiral CE offers an orthogonal enantioselectivity and is typically considered less costly than chromatographic techniques, since only minute amounts of chiral selectors are needed. Several CE approaches have been developed for chiral analysis, including chiral EKC and chiral CEC. Enantioseparations by EKC benefit from the wide variety of possible pseudostationary phases that can be employed. Chiral CEC, on the other hand, combines chromatographic separation principles with the bulk fluid movement of CE, benefitting from reduced band broadening as compared to pressure-driven systems. Although UV detection is conventionally used for these approaches, MS can also be considered. CE-MS represents a promising alternative due to the increased sensitivity and selectivity, enabling the chiral analysis of complex samples. The potential contamination of the MS ion source in EKC-MS can be overcome using partial-filling and counter-migration techniques. However, chiral analysis using monolithic and open-tubular CEC-MS awaits additional method validation and a dedicated commercial interface. Further efforts in chiral CE are expected toward the improvement of existing techniques, the development of novel pseudostationary phases, and establishing the use of chiral ionic liquids, molecular imprinted polymers, and metal-organic frameworks. These developments will certainly foster the adoption of CE(-MS) as a well-established technique in routine chiral analysis.
Collapse
Affiliation(s)
- Nicky de Koster
- Leiden Academic Centre for Drug Research, Division of Systems Biomedicine and PharmacologyLeiden UniversityLeidenThe Netherlands
| | - Charles P. Clark
- Leiden Academic Centre for Drug Research, Division of Systems Biomedicine and PharmacologyLeiden UniversityLeidenThe Netherlands
| | - Isabelle Kohler
- Division of BioAnalytical Chemistry, Department of Chemistry and Pharmaceutical Sciences, Amsterdam Institute for Molecular and Life SciencesVrije Universiteit AmsterdamAmsterdamThe Netherlands
| |
Collapse
|
2
|
Combining capillary electromigration with molecular imprinting techniques towards an optimal separation and determination. Talanta 2021; 221:121546. [DOI: 10.1016/j.talanta.2020.121546] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 08/19/2020] [Accepted: 08/20/2020] [Indexed: 01/24/2023]
|
3
|
Qin S, Jin F, Gao L, Su L, Li Y, Han S, Wang P. Determination of sulfamerazine in aquatic products by molecularly imprinted capillary electrochromatography. ROYAL SOCIETY OPEN SCIENCE 2019; 6:190119. [PMID: 31312484 PMCID: PMC6599784 DOI: 10.1098/rsos.190119] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Accepted: 05/22/2019] [Indexed: 06/10/2023]
Abstract
A molecularly imprinted monolith was prepared and evaluated for the special selective separation of sulfamerazine (SMR) by capillary electrochromatography (CEC). The single-step in situ polymerization method was applied through thermally immobilized vinyl groups of itaconic acid and a derivatization capillary column using SMR as the template. The monolith with optimal selectivity and permeability was performed at 45°C for 7 h according to the molar ratios of 1 : 4 : 10 (template/functional monomer/cross-linker). Under the optimized separation conditions of 75% acetonitrile in 20 mM phosphate buffer with pH 5.0, 15 kV applied voltage and 20°C column temperature, the imprinted monolith showed strong recognition ability for SMR and high column performance. Finally, the molecularly imprinted monolith coupled with the CEC method was successfully developed for the quantification of SMR in aquatic products, which was properly validated by a good linear relationship, recoveries and limit of detection. The coupling technique of the molecularly imprinted technology and CEC achieved pre-treatment enrichment and separation analysis in only one miniaturized chromatographic column.
Collapse
Affiliation(s)
- Shili Qin
- College of Chemistry and Chemical Engineering, Qiqihar University, Qiqihar, Heilongjiang 161006, People's Republic of China
| | - Fenglong Jin
- Laboratory of Food testing, Qiqihar Food and Drug Administration, Bukui South Street 297, Longsha District, Qiqihar 161006, People's Republic of China
| | - Lidi Gao
- College of Chemistry and Chemical Engineering, Qiqihar University, Qiqihar, Heilongjiang 161006, People's Republic of China
| | - Liqiang Su
- College of Chemistry and Chemical Engineering, Qiqihar University, Qiqihar, Heilongjiang 161006, People's Republic of China
| | - Yingjie Li
- College of Chemistry and Chemical Engineering, Qiqihar University, Qiqihar, Heilongjiang 161006, People's Republic of China
| | - Shuang Han
- College of Chemistry and Chemical Engineering, Qiqihar University, Qiqihar, Heilongjiang 161006, People's Republic of China
| | - Peng Wang
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Huanghe Road 73, Nangang District, Harbin 150000, People's Republic of China
| |
Collapse
|
4
|
Teixeira J, Tiritan ME, Pinto MMM, Fernandes C. Chiral Stationary Phases for Liquid Chromatography: Recent Developments. Molecules 2019; 24:E865. [PMID: 30823495 PMCID: PMC6429359 DOI: 10.3390/molecules24050865] [Citation(s) in RCA: 80] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Revised: 02/17/2019] [Accepted: 02/26/2019] [Indexed: 12/13/2022] Open
Abstract
The planning and development of new chiral stationary phases (CSPs) for liquid chromatography (LC) are considered as continuous and evolutionary issues since the introduction of the first CSP in 1938. The main objectives of the development strategies were to attempt the improvement of the chromatographic enantioresolution performance of the CSPs as well as enlarge their versatility and range of applications. Additionally, the transition to ultra-high-performance LC were underscored. The most recent strategies have comprised the introduction of new chiral selectors, the use of new materials as chromatographic supports or the reduction of its particle size, and the application of different synthetic approaches for preparation of CSPs. This review gathered the most recent developments associated to the different types of CSPs providing an overview of the relevant advances that are arising on LC.
Collapse
Affiliation(s)
- Joana Teixeira
- Laboratório de Química Orgânica e Farmacêutica, Departamento de Ciências Químicas, Faculdade de Farmácia, Universidade do Porto, Rua de Jorge Viterbo Ferreira, 228, 4050-313 Porto, Portugal.
| | - Maria Elizabeth Tiritan
- Laboratório de Química Orgânica e Farmacêutica, Departamento de Ciências Químicas, Faculdade de Farmácia, Universidade do Porto, Rua de Jorge Viterbo Ferreira, 228, 4050-313 Porto, Portugal.
- Interdisciplinary Centre of Marine and Environmental Research (CIIMAR), Edifício do Terminal de Cruzeiros do Porto de Leixões, Av. General Norton de Matos s/n, 4050-208 Matosinhos, Portugal.
- Cooperativa de Ensino Superior, Politécnico e Universitário (CESPU), Instituto de Investigação e Formação Avançada em Ciências e Tecnologias da Saúde (IINFACTS), Rua Central de Gandra, 1317, 4585-116 Gandra PRD, Portugal.
| | - Madalena M M Pinto
- Laboratório de Química Orgânica e Farmacêutica, Departamento de Ciências Químicas, Faculdade de Farmácia, Universidade do Porto, Rua de Jorge Viterbo Ferreira, 228, 4050-313 Porto, Portugal.
- Interdisciplinary Centre of Marine and Environmental Research (CIIMAR), Edifício do Terminal de Cruzeiros do Porto de Leixões, Av. General Norton de Matos s/n, 4050-208 Matosinhos, Portugal.
| | - Carla Fernandes
- Laboratório de Química Orgânica e Farmacêutica, Departamento de Ciências Químicas, Faculdade de Farmácia, Universidade do Porto, Rua de Jorge Viterbo Ferreira, 228, 4050-313 Porto, Portugal.
- Interdisciplinary Centre of Marine and Environmental Research (CIIMAR), Edifício do Terminal de Cruzeiros do Porto de Leixões, Av. General Norton de Matos s/n, 4050-208 Matosinhos, Portugal.
| |
Collapse
|
5
|
Wang P, Sun X, Su X, Wang T. Advancements of molecularly imprinted polymers in the food safety field. Analyst 2018; 141:3540-53. [PMID: 26937495 DOI: 10.1039/c5an01993a] [Citation(s) in RCA: 57] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Molecularly imprinted technology (MIT) has been widely employed to produce stable, robust and cheap molecularly imprinted polymer (MIP) materials that possess selective binding sites for recognition of target analytes in food, such as pesticides, veterinary drugs, mycotoxins, illegal drugs and so on. Because of high selectivity and specificity, MIPs have drawn great attention in the food safety field. In this review, the recent developments of MIPs in various applications for food safety, including sample preparation, chromatographic separation, sensing, immunoassay etc., have been summarized. We particularly discuss the advancements and limitations in these applications, as well as attempts carried out for their improvement.
Collapse
Affiliation(s)
- Peilong Wang
- Institute of Quality Standards & Testing Technology for Agriculture Products, China Agricultural Academy of Science, Beijing 100081, P.R. China.
| | - Xiaohua Sun
- Institute of Chemistry, China Academy of Science, Beijing 100190, P.R. China and Institute of New Energy, State Key Laboratory of Heavy Oil Processing, China University of Petroleum (Beijing), Beijing 102249, China
| | - Xiaoou Su
- Institute of Quality Standards & Testing Technology for Agriculture Products, China Agricultural Academy of Science, Beijing 100081, P.R. China.
| | - Tie Wang
- Institute of Chemistry, China Academy of Science, Beijing 100190, P.R. China
| |
Collapse
|
6
|
Kulsing C, Yang Y, Chowdhury JM, Boysen RI, Hearn MTW. Use of peak sharpening effects to improve the separation of chiral compounds with molecularly imprinted porous polymer layer open‐tubular capillaries. Electrophoresis 2017; 38:1179-1187. [DOI: 10.1002/elps.201600532] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2016] [Revised: 01/24/2017] [Accepted: 01/26/2017] [Indexed: 12/14/2022]
Affiliation(s)
- Chadin Kulsing
- Australian Centre for Research on Separation Science (ACROSS), Australian Research Council Special Research Centre for Green Chemistry School of Chemistry Monash University Melbourne Victoria Australia
| | - Yuanzhong Yang
- Australian Centre for Research on Separation Science (ACROSS), Australian Research Council Special Research Centre for Green Chemistry School of Chemistry Monash University Melbourne Victoria Australia
| | - Jamil M. Chowdhury
- Australian Centre for Research on Separation Science (ACROSS), Australian Research Council Special Research Centre for Green Chemistry School of Chemistry Monash University Melbourne Victoria Australia
| | - Reinhard I. Boysen
- Australian Centre for Research on Separation Science (ACROSS), Australian Research Council Special Research Centre for Green Chemistry School of Chemistry Monash University Melbourne Victoria Australia
| | - Milton T. W. Hearn
- Australian Centre for Research on Separation Science (ACROSS), Australian Research Council Special Research Centre for Green Chemistry School of Chemistry Monash University Melbourne Victoria Australia
| |
Collapse
|
7
|
Chen GN, Li N, Luo T, Dong YM. Enantiomers Recognition of Propranolol Based on Organic–Inorganic Hybrid Open-Tubular MIPs-CEC Column Using 3-(Trimethoxysilyl)Propyl Methacrylate as a Cross-Linking Monomer. J Chromatogr Sci 2017; 55:471-476. [DOI: 10.1093/chromsci/bmw204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2015] [Accepted: 12/14/2016] [Indexed: 11/12/2022]
|
8
|
Pebdani AA, Shabani AMH, Dadfarnia S, Khodadoust S. Solid phase microextraction of diclofenac using molecularly imprinted polymer sorbent in hollow fiber combined with fiber optic-linear array spectrophotometry. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2015; 147:26-30. [PMID: 25827763 DOI: 10.1016/j.saa.2015.03.057] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2014] [Revised: 02/05/2015] [Accepted: 03/02/2015] [Indexed: 06/04/2023]
Abstract
A simple solid phase microextraction method based on molecularly imprinted polymer sorbent in the hollow fiber (MIP-HF-SPME) combined with fiber optic-linear array spectrophotometer has been applied for the extraction and determination of diclofenac in environmental and biological samples. The effects of different parameters such as pH, times of extraction, type and volume of the organic solvent, stirring rate and donor phase volume on the extraction efficiency of the diclofenac were investigated and optimized. Under the optimal conditions, the calibration graph was linear (r(2)=0.998) in the range of 3.0-85.0 μg L(-1) with a detection limit of 0.7 μg L(-1) for preconcentration of 25.0 mL of the sample and the relative standard deviation (n=6) less than 5%. This method was applied successfully for the extraction and determination of diclofenac in different matrices (water, urine and plasma) and accuracy was examined through the recovery experiments.
Collapse
Affiliation(s)
- Arezou Amiri Pebdani
- Department of Chemistry, Faculty of Science, Yazd University, Yazd 89195-741, Iran
| | | | - Shayessteh Dadfarnia
- Department of Chemistry, Faculty of Science, Yazd University, Yazd 89195-741, Iran.
| | - Saeid Khodadoust
- Department of Chemistry, Behbahan Khatam Alanbia University of Technology, Behbahan, Iran
| |
Collapse
|
9
|
Whitcombe MJ, Kirsch N, Nicholls IA. Molecular imprinting science and technology: a survey of the literature for the years 2004-2011. J Mol Recognit 2014; 27:297-401. [PMID: 24700625 DOI: 10.1002/jmr.2347] [Citation(s) in RCA: 275] [Impact Index Per Article: 27.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2013] [Revised: 10/28/2013] [Accepted: 12/01/2013] [Indexed: 12/11/2022]
Abstract
Herein, we present a survey of the literature covering the development of molecular imprinting science and technology over the years 2004-2011. In total, 3779 references to the original papers, reviews, edited volumes and monographs from this period are included, along with recently identified uncited materials from prior to 2004, which were omitted in the first instalment of this series covering the years 1930-2003. In the presentation of the assembled references, a section presenting reviews and monographs covering the area is followed by sections describing fundamental aspects of molecular imprinting including the development of novel polymer formats. Thereafter, literature describing efforts to apply these polymeric materials to a range of application areas is presented. Current trends and areas of rapid development are discussed.
Collapse
|
10
|
Zhao T, Wang Q, Li J, Qiao X, Xu Z. Study on an electrochromatography method based on organic-inorganic hybrid molecularly imprinted monolith for determination of trace trichlorfon in vegetables. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE 2014; 94:1974-1980. [PMID: 24323896 DOI: 10.1002/jsfa.6511] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2013] [Accepted: 12/03/2013] [Indexed: 06/03/2023]
Abstract
BACKGROUND Organophosphorus pesticides have been widely used in agricultural production. However, the wide use of organophosphate also results in pesticide residues on the plant, which are harmful to human health because of their potential mutagenic and carcinogenic properties. Therefore, it is vital to develop a sensitive and effective analysis method to control pesticide residues. RESULTS In this study, a novel molecularly imprinted capillary monolithic column was prepared using trichlorfon as the template molecule by combining non-hydrolytic sol-gel process with a molecular imprinting technique. The resulting material was characterized by scanning electron microscopy and Fourier transform infrared. Under capillary electrochromatography, the effects of voltage, pH, ACN content and concentration of buffer solution on the electro-osmotic flow (EOF) of imprinted capillary monolithic column were evaluated in detail. Using this prepared material as stationary phase for capillary electrochromatography, a novel method of molecularly imprinted capillary electrochromatography (MICEC) for the detection of trace trichlorfon residues in vegetables was developed. Under optimal conditions, appreciable sensitivity was achieved with a LOD (S/N = 3) of 92.5 µg kg(-1) and method quantitation limit (MQL) of 305.3 µg kg(-1), respectively. The linear ranges of the calibration graph were 0.1 µg L(-1) to 10 mg L(-1). The peak area precision (RSD) for five replicate extractions of 0.01 mg L(-1) trichlorfon standard aqueous solution was 4.5%. To evaluate the accuracy of this method, the blank cucumber and cauliflower samples spiked with trichlorfon were extracted and analyzed by this method with good recoveries, ranging from 80.2% to 95.8%. Moreover, this method was successfully applied to the quantitative detection of the trichlorfon residues in leek samples. CONCLUSION With good properties of high sensitivity and simple pre-treatment, this MICEC method could provide a new tool for the rapid determination of trace trichlorfon residue in complex food samples.
Collapse
Affiliation(s)
- Tao Zhao
- College of Food Science and Engineering, Shandong Agricultural University, Taian, 271018, China
| | | | | | | | | |
Collapse
|
11
|
Kulsing C, Knob R, Macka M, Junor P, Boysen RI, Hearn MT. Molecular imprinted polymeric porous layers in open tubular capillaries for chiral separations. J Chromatogr A 2014; 1354:85-91. [DOI: 10.1016/j.chroma.2014.05.065] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2014] [Revised: 05/14/2014] [Accepted: 05/24/2014] [Indexed: 01/30/2023]
|
12
|
Ganjali MR, Faridbod F, Norouzi P. Biomimetic Molecularly Imprinted Polymers as Smart Materials and Future Perspective in Health Care. Adv Healthc Mater 2014. [DOI: 10.1002/9781118774205.ch13] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
13
|
Zhang C, Cai J, Duan Y, Xu L, Fang G, Wang S. Synthesis, characterization and application of organic-inorganic hybrid and carbaryl-imprinted capillary monolithic column. Chem Res Chin Univ 2014. [DOI: 10.1007/s40242-014-3420-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
14
|
Nema T, Chan EC, Ho PC. Applications of monolithic materials for sample preparation. J Pharm Biomed Anal 2014; 87:130-41. [DOI: 10.1016/j.jpba.2013.05.036] [Citation(s) in RCA: 65] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2013] [Revised: 05/20/2013] [Accepted: 05/22/2013] [Indexed: 11/30/2022]
|
15
|
Preparation, characterization and application of organic–inorganic hybrid caffeine imprinted monolith. J Chromatogr A 2013; 1304:10-7. [DOI: 10.1016/j.chroma.2013.06.060] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2013] [Revised: 06/23/2013] [Accepted: 06/24/2013] [Indexed: 11/18/2022]
|
16
|
Poma A, Guerreiro A, Whitcombe MJ, Piletska EV, Turner APF, Piletsky SA. Solid-Phase Synthesis of Molecularly Imprinted Polymer Nanoparticles with a Reusable Template - "Plastic Antibodies". ADVANCED FUNCTIONAL MATERIALS 2013; 23:2821-2827. [PMID: 26869870 PMCID: PMC4746745 DOI: 10.1002/adfm.201202397] [Citation(s) in RCA: 241] [Impact Index Per Article: 21.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Molecularly Imprinted Polymers (MIPs) are generic alternatives to antibodies in sensors, diagnostics and separations. To displace biomolecules without radical changes in infrastructure in device manufacture, MIPs should share their characteristics (solubility, size, specificity and affinity, localized binding domain) whilst maintaining the advantages of MIPs (low-cost, short development time and high stability) hence the interest in MIP nanoparticles. Herein we report a reusable solid-phase template approach (fully compatible with automation) for the synthesis of MIP nanoparticles and their precise manufacture using a prototype automated UV photochemical reactor. Batches of nanoparticles (30-400 nm) with narrow size distributions imprinted with: melamine (d = 60 nm, Kd = 6.3 × 10-8 m), vancomycin (d = 250 nm, Kd = 3.4 × 10-9 m), a peptide (d = 350 nm, Kd = 4.8 × 10-8 m) and proteins have been produced. Our instrument uses a column packed with glass beads, bearing the template. Process parameters are under computer control, requiring minimal manual intervention. For the first time we demonstrate the reliable re-use of molecular templates in the synthesis of MIPs (≥ 30 batches of nanoMIPs without loss of performance). NanoMIPs are produced template-free and the solid-phase acts both as template and affinity separation medium.
Collapse
Affiliation(s)
- Alessandro Poma
- Cranfield Health, Vincent Building, Cranfield University, Cranfield, Bedfordshire, MK43 0AL (UK)
| | - Antonio Guerreiro
- Cranfield Health, Vincent Building, Cranfield University, Cranfield, Bedfordshire, MK43 0AL (UK)
| | - Michael J Whitcombe
- Cranfield Health, Vincent Building, Cranfield University, Cranfield, Bedfordshire, MK43 0AL (UK)
| | - Elena V Piletska
- Cranfield Health, Vincent Building, Cranfield University, Cranfield, Bedfordshire, MK43 0AL (UK)
| | - Anthony P F Turner
- Cranfield Health, Vincent Building, Cranfield University, Cranfield, Bedfordshire, MK43 0AL (UK)
| | - Sergey A Piletsky
- Cranfield Health, Vincent Building, Cranfield University, Cranfield, Bedfordshire, MK43 0AL (UK)
| |
Collapse
|
17
|
Recent applications of molecular imprinted polymers for enantio-selective recognition. Talanta 2013; 106:45-59. [DOI: 10.1016/j.talanta.2012.11.049] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2012] [Revised: 11/23/2012] [Accepted: 11/23/2012] [Indexed: 11/19/2022]
|
18
|
Synthesis and theoretical study of molecularly imprinted monoliths for HPLC. Anal Bioanal Chem 2013; 405:2147-61. [DOI: 10.1007/s00216-012-6639-6] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2012] [Revised: 12/04/2012] [Accepted: 12/06/2012] [Indexed: 11/27/2022]
|
19
|
Cheong WJ, Yang SH. Open tubular molecular imprinted phases in chiral capillary electrochromatography. Methods Mol Biol 2013; 970:469-487. [PMID: 23283797 DOI: 10.1007/978-1-62703-263-6_30] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
A generalized preparation protocol for open tubular (OT) molecular imprinted polymer (MIP) silica capillary columns for chiral separations in capillary electrochromatography (CEC) is described. For -different chiral molecules the same general composition of the MIP reaction mixture can be used except for the choice of the specific template. This protocol is valid for a variety of templates including acidic, basic, and neutral molecules, enabling formation of rugged and porous thin MIP layers on the inner surface of the capillary resulting in columns with high chiral separation efficiencies if the template has a good chiral recognition susceptibility.
Collapse
Affiliation(s)
- Won Jo Cheong
- Department of Chemistry, Inha University, Incheon, South Korea.
| | | |
Collapse
|
20
|
Cheong WJ, Yang SH, Ali F. Molecular imprinted polymers for separation science: a review of reviews. J Sep Sci 2012; 36:609-28. [PMID: 23281278 DOI: 10.1002/jssc.201200784] [Citation(s) in RCA: 324] [Impact Index Per Article: 27.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2012] [Revised: 10/06/2012] [Accepted: 10/06/2012] [Indexed: 11/06/2022]
Abstract
Molecular imprinted polymer is an artificial receptor made by imprinting molecules of a template in a polymer matrix followed by removing the template molecules via thorough washing to give the permanent template grooves. They show favored affinity to the template molecule compared to other molecules, and this property is the basic driving force for such diverse application of this techniques. Such techniques have been increasingly employed in a wide scope of applications such as chromatography, sample pretreatment, purification, catalysts, sensors, and drug delivery, etc., mostly in bioanalytical areas. A major part of them is related to development of new stationary phases and their application in chromatography and sample pretreatment. Embodiments of molecular imprinted polymer materials have been carried out in a variety of forms such as irregularly ground particles, regular spherical particles, nanoparticles, monoliths in a stainless steel or capillary column, open tubular layers in capillaries, surface attached thin layers, membranes, and composites, etc. There have been numerous review articles on molecular imprinted polymer issues. In this special review, the reviews in recent ca. 10 years will be categorized into several subgroups according to specified topics in separation science, and each review in each subgroup will be introduced in the order of date with brief summaries and comments on new developments and different scopes of prospects. Brief summaries of each categories and conclusive future perspectives are also given.
Collapse
Affiliation(s)
- Won Jo Cheong
- Department of Chemistry, Inha University, Namku, Incheon, South Korea.
| | | | | |
Collapse
|
21
|
Tan J, Jiang ZT, Li R, Yan XP. Molecularly-imprinted monoliths for sample treatment and separation. Trends Analyt Chem 2012. [DOI: 10.1016/j.trac.2012.05.009] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
22
|
Yang SH, Zaidi SA, Cheong WJ, ALOthman ZA, ALMajid AM. Open Tubular Molecular Imprinted Polymer Fabricated in Silica Capillary for the Chiral Recognition of Neutral Enantiomers in Capillary Electrochromatography. B KOREAN CHEM SOC 2012. [DOI: 10.5012/bkcs.2012.33.5.1664] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
23
|
New trends in fast liquid chromatography for food and environmental analysis. J Chromatogr A 2012; 1228:298-323. [DOI: 10.1016/j.chroma.2011.10.091] [Citation(s) in RCA: 178] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2011] [Revised: 10/16/2011] [Accepted: 10/21/2011] [Indexed: 11/22/2022]
|
24
|
Zheng C, Huang YP, Liu ZS. Recent developments and applications of molecularly imprinted monolithic column for HPLC and CEC. J Sep Sci 2011; 34:1988-2002. [DOI: 10.1002/jssc.201100164] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2011] [Revised: 03/17/2011] [Accepted: 03/17/2011] [Indexed: 11/06/2022]
|
25
|
Huang BY, Chen YC, Liu CY. An insight into the mechanism of CEC separation of template analogues on a norepinephrine-imprinted monolith. J Sep Sci 2011; 34:2293-300. [PMID: 21538991 DOI: 10.1002/jssc.201000918] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2010] [Revised: 03/17/2011] [Accepted: 03/18/2011] [Indexed: 11/09/2022]
Abstract
A monolith molecularly imprinted polymer (MIP) column was prepared from template (-)-norepinephrine, functional monomer (itaconic acid), and a cross-linker (either ethylene glycol dimethacrylate or divinylbenzene) in porogen N,N-dimethylformamide. Understanding the molecular recognition of a template using an MIP seems feasible. However, it is hard to explain the recognition properties of their analogues on an MIP. The separation mechanism was investigated with the addition of charged surfactants, native and derivatised β-cyclodextrin (β-CD), achiral crown ether, etc. to determine the retention behaviour of the template analogues. The addition of organic modifiers and the adjustment of separation conditions were used to manipulate the selectivity. No chiral recognition was observed under most of the test conditions except the experiment with the charged β-CD on the divinylbenzene-MIP column. The different experimental conditions led to differences in the mobilities of the analytes and resulted in remarkable enantiomeric separation of the template. We confirmed the presence of mixed-mode selectivity of the stationary phase based on hydrogen bonding, hydroelectric and hydrophobic interactions, and the electrophoretic mode.
Collapse
Affiliation(s)
- Bao-Yu Huang
- Department of Chemistry, National Taiwan University, Taipei, Taiwan
| | | | | |
Collapse
|
26
|
Shi XX, Xu L, Duan HQ, Huang YP, Liu ZS. CEC separation of ofloxacin enantiomers using imprinted microparticles prepared in molecular crowding conditions. Electrophoresis 2011; 32:1348-56. [DOI: 10.1002/elps.201000515] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2010] [Revised: 01/19/2011] [Accepted: 01/19/2011] [Indexed: 11/08/2022]
|
27
|
He J, Fang G, Deng Q, Wang S. Preparation, characterization and application of organic–inorganic hybrid ractopamine multi-template molecularly imprinted capillary monolithic column. Anal Chim Acta 2011; 692:57-62. [DOI: 10.1016/j.aca.2011.02.056] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2010] [Revised: 02/23/2011] [Accepted: 02/28/2011] [Indexed: 10/18/2022]
|
28
|
Zaidi SA, Lee SM, Cheong WJ. Open tubular capillary columns with basic templates made by the generalized preparation protocol in capillary electrochromatography chiral separation and template structural effects on chiral separation capability. J Chromatogr A 2011; 1218:1291-9. [DOI: 10.1016/j.chroma.2010.12.117] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2010] [Revised: 12/27/2010] [Accepted: 12/31/2010] [Indexed: 11/29/2022]
|
29
|
Examination of Template Structural Effects on CEC Chiral Separation Performance of Molecule Imprinted Polymers Made by a Generalized Preparation Protocol. Chromatographia 2011. [DOI: 10.1007/s10337-011-1934-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
30
|
Preparation and evaluation of a monolithic molecularly imprinted polymer for the chiral separation of neurotransmitters and their analogues by capillary electrochromatography. J Chromatogr A 2011; 1218:849-55. [DOI: 10.1016/j.chroma.2010.12.054] [Citation(s) in RCA: 111] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2010] [Revised: 12/08/2010] [Accepted: 12/10/2010] [Indexed: 11/20/2022]
|
31
|
Qu P, Lei J, Sheng J, Zhang L, Ju H. Simultaneous multiple enantioseparation with a one-pot imprinted microfluidic channel by microchip capillary electrochromatography. Analyst 2011; 136:920-6. [DOI: 10.1039/c0an00559b] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
32
|
Chromatography, Solid-Phase Extraction, and Capillary Electrochromatography with MIPs. Top Curr Chem (Cham) 2010; 325:267-306. [DOI: 10.1007/128_2010_100] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/18/2023]
|
33
|
He JX, Fang GZ, Yao YC, Wang S. Preparation and characterization of molecularly imprinted silica monolith for screening sulfamethazine. J Sep Sci 2010; 33:3263-71. [DOI: 10.1002/jssc.200900650] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
34
|
Zhang Z, Wu R, Wu M, Zou H. Recent progress of chiral monolithic stationary phases in CEC and capillary LC. Electrophoresis 2010; 31:1457-66. [DOI: 10.1002/elps.200900672] [Citation(s) in RCA: 61] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
35
|
Zaidi SA, Han KM, Hwang DG, Cheong WJ. Preparation of open tubular molecule imprinted polymer capillary columns with various templates by a generalized procedure and their chiral and non-chiral separation performance in CEC. Electrophoresis 2010; 31:1019-28. [DOI: 10.1002/elps.200900457] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
36
|
Birnbaumer GM, Lieberzeit PA, Richter L, Schirhagl R, Milnera M, Dickert FL, Bailey A, Ertl P. Detection of viruses with molecularly imprinted polymers integrated on a microfluidic biochip using contact-less dielectric microsensors. LAB ON A CHIP 2009; 9:3549-56. [PMID: 20024035 DOI: 10.1039/b914738a] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Rapid detection of viral contamination remains a pressing issue in various fields related to human health including clinical diagnostics, the monitoring of food-borne pathogens, the detection of biological warfare agents as well as in viral clearance studies for biopharmaceutical products. The majority of currently available assays for virus detection are expensive, time-consuming, and labor-intensive. In the present work we report the creation of a novel micro total analysis system (microTAS) capable of continuously monitoring viral contamination with high sensitivity and selectivity. The specific interaction between shape and surface chemistry between molecular imprinted polymer (MIP) and virus resulted in the elimination of non-specific interaction in the present sensor configuration. The additional integration of the blank (non-imprinted) polymer further allowed for the identification of non-specific adsorption events. The novel combination of microfluidics containing integrated native polymer and MIP with contact-less dielectric microsensors is evaluated using the Tobacco Mosaic Virus (TMV) and the Human Rhinovirus serotype 2 (HRV2). Results show that viral binding and dissociation events can be readily detected using contact-less bioimpedance spectroscopy optimized for specific frequencies. In the present study optimum sensor performance was achieved at 203 kHz within the applied frequency range of 5-500 kHz. Complete removal of the virus from the MIP and device reusability is successfully demonstrated following a 50-fold increase in fluid velocity. Evaluation of the microfluidic biochip revealed that microchip technology is ideally suited to detect a broader range of viral contaminations with high sensitivity by selectively adjusting microfluidic conditions, sensor geometries and choice of MIP polymeric material.
Collapse
Affiliation(s)
- Gerald M Birnbaumer
- Department of Health & Environment, Nano Systems, Austrian Institute of Technology GmbH, Donau-City-Street 1, 1220 Vienna, Austria
| | | | | | | | | | | | | | | |
Collapse
|
37
|
Feng L, Pamidighantam B, Lauterbur PC. Microwave-assisted sol–gel synthesis for molecular imprinting. Anal Bioanal Chem 2009; 396:1607-12. [DOI: 10.1007/s00216-009-3311-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2009] [Revised: 11/10/2009] [Accepted: 11/11/2009] [Indexed: 11/28/2022]
|
38
|
Svec F. CEC: selected developments that caught my eye since the year 2000. Electrophoresis 2009; 30 Suppl 1:S68-82. [PMID: 19517503 DOI: 10.1002/elps.200900062] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
During the last decade, a number of new developments have emerged in the field of CEC. This paper focuses only on monolithic columns prepared from synthetic polymers. Monolithic columns have become a well-established format of stationary phases for CEC immediately after their inception in the mid-1990s. They are readily prepared in situ from liquid precursors. Also, the control over both porous properties and surface chemistries is easy to achieve. These advantages make the monolithic separation media an attractive alternative to capillary columns packed with particulate materials. Since the number of papers concerned with just this single topic of polymer-based monolithic CEC columns is large, this overview describes only those approaches this author found interesting.
Collapse
Affiliation(s)
- Frantisek Svec
- The Molecular Foundry, E. O. Lawrence Berkeley National Laboratory, Berkeley, CA 94720-8197, USA.
| |
Collapse
|
39
|
Huang YP, Liu ZS, Zheng C, Gao RY. Recent developments of molecularly imprinted polymer in CEC. Electrophoresis 2009; 30:155-62. [PMID: 19072928 DOI: 10.1002/elps.200800410] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
This review focuses on developments in the field of molecularly imprinted polymer (MIP) for CEC since August 2006. New technique of CEC-based MIP, e.g. covalent approach through the formation of Schiff base, miniemulsion polymerization, non-hydrolytic sol-gel methodology, MIP-derivatized silica monolithic column, are discussed from the view of MIP preparation. Some thoughts on potential future directions are also expressed in this review.
Collapse
Affiliation(s)
- Yan-Ping Huang
- College of Pharmacy, Tianjin Medical University, Tianjin, China
| | | | | | | |
Collapse
|
40
|
Zaidi SA, Cheong WJ. Long open tubular molecule imprinted polymer capillary columns with excellent separation efficiencies in chiral and non-chiral separation by capillary electrochromatography. Electrophoresis 2009; 30:1603-7. [DOI: 10.1002/elps.200800541] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
41
|
Zaidi SA, Cheong WJ. Preparation of an open-tubular capillary column with a monolithic layer of S-ketoprofen imprinted and 4-styrenesulfonic acid incorporated polymer and its enhanced chiral separation performance in capillary electrochromatography. J Chromatogr A 2009; 1216:2947-52. [DOI: 10.1016/j.chroma.2008.08.015] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2008] [Revised: 08/05/2008] [Accepted: 08/08/2008] [Indexed: 10/21/2022]
|
42
|
Open tubular layer of S-ofloxacin imprinted polymer fabricated in silica capillary for chiral CEC separation. J Sep Sci 2009; 32:996-1001. [DOI: 10.1002/jssc.200800631] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
43
|
Lara FJ, Lynen F, Sandra P, García‐Campaña AM, Alés‐Barrero F. Evaluation of a molecularly imprinted polymer as in‐line concentrator in capillary electrophoresis. Electrophoresis 2008; 29:3834-41. [DOI: 10.1002/elps.200700889] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Francisco J. Lara
- Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Avd. Fuentenueva s/n, Granada, Spain
| | - Fréderic Lynen
- Laboratory of Separation Sciences, Department of Organic Chemistry, Ghent University, Ghent, Belgium
| | - Pat Sandra
- Laboratory of Separation Sciences, Department of Organic Chemistry, Ghent University, Ghent, Belgium
| | - Ana M. García‐Campaña
- Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Avd. Fuentenueva s/n, Granada, Spain
| | - Fermín Alés‐Barrero
- Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Avd. Fuentenueva s/n, Granada, Spain
| |
Collapse
|
44
|
ZHENG C, LIU ZS, GAO RY, ZHANG YK. Mechanism of Molecular Recognition on Tetrapetide-imprinted Monolith by Capillary Electrochromatography. CHINESE J CHEM 2008. [DOI: 10.1002/cjoc.200890335] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
45
|
Zaidi SA, Cheong WJ. Robust open tubular layer ofS-ketoprofen imprinted polymer for chiral LC separation. J Sep Sci 2008; 31:2962-70. [DOI: 10.1002/jssc.200800160] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
46
|
Pichon V, Chapuis-Hugon F. Role of molecularly imprinted polymers for selective determination of environmental pollutants—A review. Anal Chim Acta 2008; 622:48-61. [DOI: 10.1016/j.aca.2008.05.057] [Citation(s) in RCA: 292] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2008] [Revised: 05/22/2008] [Accepted: 05/23/2008] [Indexed: 10/22/2022]
|
47
|
Wu R, Hu L, Wang F, Ye M, Zou H. Recent development of monolithic stationary phases with emphasis on microscale chromatographic separation. J Chromatogr A 2008; 1184:369-92. [DOI: 10.1016/j.chroma.2007.09.022] [Citation(s) in RCA: 232] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2007] [Revised: 09/06/2007] [Accepted: 09/11/2007] [Indexed: 12/28/2022]
|
48
|
Cacho C, Schweitz L, Turiel E, Pérez-Conde C. Molecularly imprinted capillary electrochromatography for selective determination of thiabendazole in citrus samples. J Chromatogr A 2008; 1179:216-23. [DOI: 10.1016/j.chroma.2007.11.097] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2007] [Revised: 11/09/2007] [Accepted: 11/28/2007] [Indexed: 10/22/2022]
|
49
|
Wang HF, Zhu YZ, Lin JP, Yan XP. Fabrication of molecularly imprinted hybrid monolithsvia a room temperature ionic liquid-mediated nonhydrolytic sol–gel route for chiral separation of zolmitriptan by capillary electrochromatography. Electrophoresis 2008; 29:952-9. [DOI: 10.1002/elps.200700402] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
50
|
|